From 1189ec781b2ddb108d1c32f89c77a04ee9ade861 Mon Sep 17 00:00:00 2001 From: Jesus Climent Date: Mon, 27 Dec 2021 18:31:36 +0000 Subject: [PATCH 1/2] Updated the RGB PCB Changes: * Updated jumpers with bypass tabs. Solder once for bypassing the section. * Updated footprints with silkscreen for the GND tab on the LEDs. * Cleaned a bunch of tracks, consolidated GND/VCC with consistent width. --- .../SofleKeyboardBottomPlate.kicad_pcb | 1050 + .../PCBBottom/SofleKeyboardBottomPlate.pro | 61 + .../PCBTop/SofleKeyboardTopPlate.kicad_pcb | 1706 + .../Case/PCBTop/SofleKeyboardTopPlate.pro | 61 + Sofle_RGB_v3/Case/PCBTop/fp-info-cache | 83042 +++++++++++++++ Sofle_RGB_v3/Case/Sofle-RGB-tenting.svg | 868 + Sofle_RGB_v3/Case/Sofle_RGB.svg | 708 + Sofle_RGB_v3/Case/oled_cover.svg | 153 + Sofle_RGB_v3/PCB/SofleKeyboard-cache.lib | 387 + Sofle_RGB_v3/PCB/SofleKeyboard-rescue.lib | 642 + Sofle_RGB_v3/PCB/SofleKeyboard.dcm | 3 + Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb | 16436 +++ Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak | 16436 +++ Sofle_RGB_v3/PCB/SofleKeyboard.lib | 42 + Sofle_RGB_v3/PCB/SofleKeyboard.net | 899 + Sofle_RGB_v3/PCB/SofleKeyboard.pro | 43 + Sofle_RGB_v3/PCB/SofleKeyboard.sch | 2627 + Sofle_RGB_v3/PCB/SofleKeyboard.sch-bak | 2627 + .../PCB/SofleRGB.pretty/1pin_conn.kicad_mod | 33 + .../PCB/SofleRGB.pretty/3x1header.kicad_mod | 35 + .../PCB/SofleRGB.pretty/HOLE_M2_TH.kicad_mod | 10 + .../PCB/SofleRGB.pretty/Jumper.kicad_mod | 22 + .../PCB/SofleRGB.pretty/LED.kicad_mod | 53 + .../PCB/SofleRGB.pretty/M2_HOLE_PCB.kicad_mod | 9 + .../PCB/SofleRGB.pretty/MJ-4PP-9.kicad_mod | 43 + .../PCB/SofleRGB.pretty/OLED_4Pin.kicad_mod | 22 + .../PCB/SofleRGB.pretty/ProMicro.kicad_mod | 78 + .../SofleRGB.pretty/RESISTOR_mini.kicad_mod | 34 + ...h_Vertical_H20mm-keebio_modified.kicad_mod | 56 + .../SK6812MINI_and_cherry.kicad_mod | 121 + .../SK6812MINI_underglow_dev.kicad_mod | 28 + .../TACT_SWITCH_TVBP06.kicad_mod | 29 + .../PCB/SofleRGB.pretty/crkbd-diode.kicad_mod | 36 + .../PCB/SofleRGB.pretty/gecko-logo.kicad_mod | 160 + .../PCB/SofleRGB.pretty/jumper_data.kicad_mod | 23 + .../PCB/custom mods/big gecko.kicad_mod | 86 + .../PCB/custom mods/gecko-logo.kicad_mod | 86 + Sofle_RGB_v3/PCB/custom mods/logo.kicad_mod | 86 + Sofle_RGB_v3/PCB/fp-info-cache | 83161 ++++++++++++++++ Sofle_RGB_v3/PCB/fp-lib-table | 3 + Sofle_RGB_v3/PCB/sym-lib-table | 4 + 41 files changed, 212009 insertions(+) create mode 100644 Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.kicad_pcb create mode 100644 Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.pro create mode 100644 Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.kicad_pcb create mode 100644 Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.pro create mode 100644 Sofle_RGB_v3/Case/PCBTop/fp-info-cache create mode 100644 Sofle_RGB_v3/Case/Sofle-RGB-tenting.svg create mode 100644 Sofle_RGB_v3/Case/Sofle_RGB.svg create mode 100644 Sofle_RGB_v3/Case/oled_cover.svg create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard-cache.lib create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard-rescue.lib create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.dcm create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.lib create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.net create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.pro create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.sch create mode 100644 Sofle_RGB_v3/PCB/SofleKeyboard.sch-bak create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/1pin_conn.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/3x1header.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/HOLE_M2_TH.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/Jumper.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/LED.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/M2_HOLE_PCB.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/MJ-4PP-9.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/OLED_4Pin.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/ProMicro.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/RESISTOR_mini.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_and_cherry.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_underglow_dev.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/TACT_SWITCH_TVBP06.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/crkbd-diode.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/gecko-logo.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/SofleRGB.pretty/jumper_data.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/custom mods/big gecko.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/custom mods/gecko-logo.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/custom mods/logo.kicad_mod create mode 100644 Sofle_RGB_v3/PCB/fp-info-cache create mode 100644 Sofle_RGB_v3/PCB/fp-lib-table create mode 100644 Sofle_RGB_v3/PCB/sym-lib-table diff --git a/Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.kicad_pcb b/Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.kicad_pcb new file mode 100644 index 00000000..35efda8e --- /dev/null +++ b/Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.kicad_pcb @@ -0,0 +1,1050 @@ +(kicad_pcb (version 20171130) (host pcbnew "(5.1.6)-1") + + (general + (thickness 1.6) + (drawings 41) + (tracks 0) + (zones 0) + (modules 15) + (nets 1) + ) + + (page A4) + (layers + (0 F.Cu signal) + (31 B.Cu signal) + (32 B.Adhes user hide) + (33 F.Adhes user hide) + (34 B.Paste user) + (35 F.Paste user hide) + (36 B.SilkS user) + (37 F.SilkS user) + (38 B.Mask user) + (39 F.Mask user) + (40 Dwgs.User user hide) + (41 Cmts.User user hide) + (42 Eco1.User user hide) + (43 Eco2.User user hide) + (44 Edge.Cuts user) + (45 Margin user hide) + (46 B.CrtYd user) + (47 F.CrtYd user hide) + (48 B.Fab user) + (49 F.Fab user hide) + ) + + (setup + (last_trace_width 0.25) + (trace_clearance 0.2) + (zone_clearance 0.508) + (zone_45_only no) + (trace_min 0.2) + (via_size 0.6) + (via_drill 0.4) + (via_min_size 0.4) + (via_min_drill 0.3) + (uvia_size 0.3) + (uvia_drill 0.1) + (uvias_allowed no) + (uvia_min_size 0.2) + (uvia_min_drill 0.1) + (edge_width 0.15) + (segment_width 0.2) + (pcb_text_width 0.3) + (pcb_text_size 1.5 1.5) + (mod_edge_width 0.15) + (mod_text_size 1 1) + (mod_text_width 0.15) + (pad_size 4 4) + (pad_drill 2.2) + (pad_to_mask_clearance 0.2) + (aux_axis_origin 0 0) + (visible_elements 7FFFFFFF) + (pcbplotparams + (layerselection 0x010f0_ffffffff) + (usegerberextensions false) + (usegerberattributes false) + (usegerberadvancedattributes false) + (creategerberjobfile false) + (excludeedgelayer true) + (linewidth 0.100000) + (plotframeref false) + (viasonmask false) + (mode 1) + (useauxorigin false) + (hpglpennumber 1) + (hpglpenspeed 20) + (hpglpendiameter 15.000000) + (psnegative false) + (psa4output false) + (plotreference true) + (plotvalue true) + (plotinvisibletext false) + (padsonsilk false) + (subtractmaskfromsilk false) + (outputformat 1) + (mirror false) + (drillshape 0) + (scaleselection 1) + (outputdirectory "gerbers/")) + ) + + (net 0 "") + + (net_class Default "This is the default net class." + (clearance 0.2) + (trace_width 0.25) + (via_dia 0.6) + (via_drill 0.4) + (uvia_dia 0.3) + (uvia_drill 0.1) + ) + + (module Dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F8157B8) + (at 187.96 130.81 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) + (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) + (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) + (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) + (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) + (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) + (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) + (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) + (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) + (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) + (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) + (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) + (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) + (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) + (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) + (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) + (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) + (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) + (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) + (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) + (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) + (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) + (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) + (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) + (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) + (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) + (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) + (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) + (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) + (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) + (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) + (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) + (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) + (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) + (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) + (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) + (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) + (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) + (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) + (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) + (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) + (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) + (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) + (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) + (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) + (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) + (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) + (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) + (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) + (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) + (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) + (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) + (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) + (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) + (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) + (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) + (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) + (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) + (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) + (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) + (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) + (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) + (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) + (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) + (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) + (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) + (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) + (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) + (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) + (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) + (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) + (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) + (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) + (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) + (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) + (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) + (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) + (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) + (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) + (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) + (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) + (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) + (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) + (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) + (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) + (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) + (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) + (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) + (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) + (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) + (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) + (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) + (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) + (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) + (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) + (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) + (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) + (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) + (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) + (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) + (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) + (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) + (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) + (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) + (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) + (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) + (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) + (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) + (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) + (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) + (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) + (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) + (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) + (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) + (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) + (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) + (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) + (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) + (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) + (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) + (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) + (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) + (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) + (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) + (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) + (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) + (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) + (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) + (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) + (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) + (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) + (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) + (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) + (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) + (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) + (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) + (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) + (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) + (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) + (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) + (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) + (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) + (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) + (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) + (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) + (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) + (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) + (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) + (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) + (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) + (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) + (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) + ) + + (module "Dane:big gecko" (layer B.Cu) (tedit 0) (tstamp 5F815775) + (at 129.54 116.84 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_poly (pts (xy 4.008792 12.306448) (xy 4.197112 12.00748) (xy 4.404044 11.54421) (xy 4.495193 11.310908) + (xy 4.645632 10.936371) (xy 4.784941 10.627718) (xy 4.898265 10.415388) (xy 4.970751 10.329822) + (xy 4.974167 10.329363) (xy 5.050092 10.252351) (xy 5.079949 10.045593) (xy 5.08 10.034713) + (xy 5.113317 9.755915) (xy 5.195135 9.454602) (xy 5.211393 9.41171) (xy 5.267201 9.250425) + (xy 5.296179 9.086173) (xy 5.298526 8.878855) (xy 5.274438 8.588374) (xy 5.224113 8.174631) + (xy 5.217722 8.125525) (xy 5.092658 7.167724) (xy 6.032483 5.933362) (xy 6.332372 5.539501) + (xy 6.595504 5.193938) (xy 6.805253 4.918506) (xy 6.944992 4.735039) (xy 6.997831 4.665712) + (xy 7.091364 4.66575) (xy 7.304027 4.711479) (xy 7.595899 4.790485) (xy 7.927058 4.890351) + (xy 8.257583 4.998662) (xy 8.547553 5.103002) (xy 8.757046 5.190955) (xy 8.83584 5.237342) + (xy 8.974014 5.408051) (xy 9.138994 5.68053) (xy 9.305645 6.003434) (xy 9.44883 6.325416) + (xy 9.543412 6.595131) (xy 9.567334 6.731543) (xy 9.621743 6.920752) (xy 9.750929 7.012322) + (xy 9.903831 6.975306) (xy 9.930738 6.951796) (xy 9.984745 6.830536) (xy 9.925047 6.687702) + (xy 9.863269 6.505829) (xy 9.82615 6.236452) (xy 9.821334 6.102854) (xy 9.846313 5.810759) + (xy 9.931342 5.650976) (xy 10.091553 5.620288) (xy 10.342079 5.715478) (xy 10.678968 5.920542) + (xy 10.977005 6.115371) (xy 11.166712 6.22205) (xy 11.278384 6.249676) (xy 11.342316 6.207344) + (xy 11.378883 6.130693) (xy 11.390757 5.94518) (xy 11.262293 5.850421) (xy 11.178118 5.842) + (xy 11.028157 5.774518) (xy 10.845381 5.606436) (xy 10.671308 5.389302) (xy 10.547456 5.174661) + (xy 10.514483 5.018067) (xy 10.603837 4.893628) (xy 10.791938 4.759518) (xy 11.022617 4.643398) + (xy 11.239706 4.572926) (xy 11.387038 4.575764) (xy 11.398102 4.582931) (xy 11.543923 4.621711) + (xy 11.695131 4.571846) (xy 11.767317 4.462096) (xy 11.76737 4.457108) (xy 11.711584 4.258201) + (xy 11.571384 4.188517) (xy 11.446334 4.224592) (xy 11.232943 4.292421) (xy 10.961049 4.320264) + (xy 10.686957 4.310168) (xy 10.466973 4.264179) (xy 10.357659 4.185027) (xy 10.385497 4.056494) + (xy 10.506628 3.868428) (xy 10.680968 3.665621) (xy 10.868434 3.492869) (xy 11.028942 3.394964) + (xy 11.072072 3.386666) (xy 11.156678 3.328096) (xy 11.159805 3.196456) (xy 11.096428 3.057855) + (xy 10.981522 2.978401) (xy 10.979499 2.978001) (xy 10.831494 3.019731) (xy 10.781916 3.114629) + (xy 10.687751 3.22331) (xy 10.475353 3.370838) (xy 10.185155 3.536905) (xy 9.85759 3.701206) + (xy 9.533091 3.843434) (xy 9.25209 3.943281) (xy 9.057977 3.980444) (xy 8.900327 3.96853) + (xy 8.612074 3.935059) (xy 8.2299 3.884706) (xy 7.790492 3.822147) (xy 7.638629 3.799537) + (xy 7.20791 3.737089) (xy 6.841258 3.688476) (xy 6.568964 3.657362) (xy 6.421322 3.647409) + (xy 6.403881 3.65026) (xy 6.352335 3.730308) (xy 6.228652 3.927343) (xy 6.049727 4.214317) + (xy 5.832458 4.564178) (xy 5.760223 4.680749) (xy 5.535213 5.0386) (xy 5.342323 5.335072) + (xy 5.198334 5.545152) (xy 5.120027 5.643829) (xy 5.11146 5.647682) (xy 5.108142 5.558319) + (xy 5.114837 5.322827) (xy 5.130465 4.964044) (xy 5.153947 4.50481) (xy 5.184204 3.967966) + (xy 5.214635 3.464599) (xy 5.348626 1.312333) (xy 4.494901 -0.325997) (xy 4.247641 -0.809688) + (xy 4.033833 -1.245714) (xy 3.864036 -1.611031) (xy 3.748813 -1.882597) (xy 3.698722 -2.03737) + (xy 3.699431 -2.061664) (xy 3.764335 -2.155813) (xy 3.914025 -2.36587) (xy 4.133465 -2.67096) + (xy 4.407619 -3.050208) (xy 4.72145 -3.482739) (xy 4.886202 -3.709242) (xy 5.211588 -4.158048) + (xy 5.501956 -4.562034) (xy 5.742876 -4.900838) (xy 5.919918 -5.154098) (xy 6.018652 -5.301451) + (xy 6.034192 -5.329213) (xy 5.974578 -5.3972) (xy 5.796802 -5.549089) (xy 5.520049 -5.769738) + (xy 5.163506 -6.044007) (xy 4.746359 -6.356755) (xy 4.529667 -6.516513) (xy 4.087721 -6.842454) + (xy 3.694126 -7.136281) (xy 3.368695 -7.38291) (xy 3.131242 -7.567258) (xy 3.001582 -7.674241) + (xy 2.983499 -7.693548) (xy 3.031808 -7.781953) (xy 3.189871 -7.923749) (xy 3.418502 -8.091759) + (xy 3.678515 -8.258807) (xy 3.930726 -8.397718) (xy 4.106334 -8.472264) (xy 4.412245 -8.532817) + (xy 4.852633 -8.562141) (xy 5.291667 -8.561172) (xy 5.699381 -8.544809) (xy 5.975175 -8.517608) + (xy 6.156416 -8.472635) (xy 6.280471 -8.402956) (xy 6.318106 -8.370696) (xy 6.455348 -8.26034) + (xy 6.550458 -8.26669) (xy 6.640475 -8.345903) (xy 6.73397 -8.503449) (xy 6.735869 -8.611508) + (xy 6.693626 -8.741251) (xy 6.688667 -8.769925) (xy 6.61488 -8.794702) (xy 6.436877 -8.805327) + (xy 6.431852 -8.805334) (xy 6.209851 -8.843847) (xy 5.922339 -8.942397) (xy 5.749288 -9.021077) + (xy 5.503488 -9.156939) (xy 5.380292 -9.266966) (xy 5.345425 -9.389048) (xy 5.349936 -9.462532) + (xy 5.404373 -9.617435) (xy 5.549696 -9.76466) (xy 5.818351 -9.936095) (xy 5.849987 -9.953969) + (xy 6.135973 -10.104049) (xy 6.394482 -10.222203) (xy 6.539148 -10.273783) (xy 6.740576 -10.381449) + (xy 6.823204 -10.546402) (xy 6.764427 -10.721065) (xy 6.598243 -10.825684) (xy 6.423925 -10.808936) + (xy 6.310694 -10.677535) (xy 6.31054 -10.677053) (xy 6.2296 -10.573265) (xy 6.041563 -10.490123) + (xy 5.715668 -10.414131) (xy 5.70793 -10.412666) (xy 5.408003 -10.360645) (xy 5.227642 -10.348569) + (xy 5.120999 -10.380156) (xy 5.042228 -10.459119) (xy 5.036122 -10.467114) (xy 4.956084 -10.596938) + (xy 4.920577 -10.745522) (xy 4.925177 -10.962647) (xy 4.963532 -11.284063) (xy 5.024702 -11.554672) + (xy 5.1229 -11.688914) (xy 5.175385 -11.711335) (xy 5.284364 -11.775531) (xy 5.274491 -11.913776) + (xy 5.26147 -11.951289) (xy 5.136793 -12.13149) (xy 4.97723 -12.180574) (xy 4.834055 -12.097138) + (xy 4.77239 -11.964663) (xy 4.703558 -11.749624) (xy 4.593307 -11.462588) (xy 4.521332 -11.292838) + (xy 4.376632 -11.014322) (xy 4.236003 -10.865797) (xy 4.11272 -10.817832) (xy 3.992927 -10.807882) + (xy 3.909496 -10.856272) (xy 3.837014 -10.996375) (xy 3.750065 -11.261568) (xy 3.733853 -11.315367) + (xy 3.656769 -11.620774) (xy 3.615975 -11.883137) (xy 3.618542 -12.031873) (xy 3.604244 -12.217563) + (xy 3.486621 -12.329447) (xy 3.322945 -12.347405) (xy 3.170487 -12.251316) (xy 3.137425 -12.200891) + (xy 3.102392 -12.038553) (xy 3.185683 -11.929135) (xy 3.245412 -11.854815) (xy 3.279239 -11.731973) + (xy 3.289678 -11.527733) (xy 3.279244 -11.209225) (xy 3.262465 -10.925411) (xy 3.23909 -10.590975) + (xy 3.208115 -10.322389) (xy 3.155655 -10.091708) (xy 3.067826 -9.87099) (xy 2.930743 -9.632288) + (xy 2.73052 -9.34766) (xy 2.453274 -8.989161) (xy 2.085118 -8.528847) (xy 2.04986 -8.484966) + (xy 1.838623 -8.230376) (xy 1.677213 -8.033819) (xy 1.573738 -7.874506) (xy 1.536304 -7.731646) + (xy 1.573018 -7.584448) (xy 1.691989 -7.412123) (xy 1.901321 -7.193879) (xy 2.209124 -6.908926) + (xy 2.623503 -6.536474) (xy 2.910989 -6.276605) (xy 4.086311 -5.208104) (xy 3.385888 -4.551385) + (xy 3.102975 -4.290276) (xy 2.865272 -4.078676) (xy 2.69948 -3.939842) (xy 2.633899 -3.896326) + (xy 2.57027 -3.964205) (xy 2.439322 -4.146134) (xy 2.262183 -4.411767) (xy 2.119776 -4.634828) + (xy 1.726054 -5.188633) (xy 1.228388 -5.777403) (xy 0.67124 -6.354557) (xy 0.099071 -6.873513) + (xy -0.351238 -7.22374) (xy -0.816039 -7.519737) (xy -1.372154 -7.82248) (xy -1.962521 -8.104647) + (xy -2.530077 -8.338915) (xy -3.005666 -8.494765) (xy -3.577315 -8.618661) (xy -4.222851 -8.712809) + (xy -4.87654 -8.770592) (xy -5.472646 -8.785393) (xy -5.760882 -8.772109) (xy -6.773518 -8.605423) + (xy -7.750544 -8.280201) (xy -8.678015 -7.805848) (xy -9.541983 -7.191771) (xy -10.328505 -6.447374) + (xy -11.023634 -5.582064) (xy -11.423444 -4.953) (xy -11.618595 -4.614334) (xy -11.383689 -4.910667) + (xy -11.097038 -5.242669) (xy -10.728255 -5.627146) (xy -10.314829 -6.028936) (xy -9.894248 -6.412875) + (xy -9.504001 -6.743799) (xy -9.181575 -6.986544) (xy -9.144 -7.011478) (xy -8.301169 -7.471008) + (xy -7.413523 -7.792745) (xy -6.506325 -7.972352) (xy -5.604838 -8.005491) (xy -4.734323 -7.887822) + (xy -4.4603 -7.815795) (xy -3.928496 -7.625735) (xy -3.326712 -7.358476) (xy -2.716103 -7.043948) + (xy -2.157827 -6.712081) (xy -2.024415 -6.623671) (xy -1.568021 -6.291266) (xy -1.159217 -5.94097) + (xy -0.77772 -5.54859) (xy -0.403251 -5.089936) (xy -0.015528 -4.540817) (xy 0.405731 -3.877043) + (xy 0.721031 -3.348967) (xy 1.214673 -2.506933) (xy 0.416836 -1.766246) (xy 0.118329 -1.497962) + (xy -0.132987 -1.288836) (xy -0.313654 -1.157147) (xy -0.400215 -1.121172) (xy -0.404075 -1.126613) + (xy -0.420423 -1.245302) (xy -0.448572 -1.497282) (xy -0.484767 -1.847228) (xy -0.52525 -2.259812) + (xy -0.531075 -2.320866) (xy -0.635 -3.414065) (xy -1.993674 -2.10384) (xy -2.453761 -1.663339) + (xy -2.814034 -1.327474) (xy -3.093861 -1.080596) (xy -3.312614 -0.907056) (xy -3.489664 -0.791204) + (xy -3.644379 -0.717392) (xy -3.754993 -0.680882) (xy -4.059333 -0.627232) (xy -4.436269 -0.605791) + (xy -4.839055 -0.613764) (xy -5.220949 -0.648357) (xy -5.535206 -0.706776) (xy -5.735081 -0.786228) + (xy -5.752868 -0.800293) (xy -5.890426 -0.884312) (xy -6.026935 -0.833959) (xy -6.047621 -0.819224) + (xy -6.165791 -0.658346) (xy -6.147055 -0.49585) (xy -6.008391 -0.390139) (xy -5.918991 -0.376733) + (xy -5.719942 -0.341037) (xy -5.451712 -0.25496) (xy -5.170139 -0.141382) (xy -4.931064 -0.023183) + (xy -4.790326 0.076757) (xy -4.780521 0.089756) (xy -4.744706 0.290207) (xy -4.876575 0.502113) + (xy -5.174969 0.723995) (xy -5.352301 0.821142) (xy -5.640886 0.963725) (xy -5.885397 1.076887) + (xy -6.0325 1.135985) (xy -6.153923 1.244416) (xy -6.170799 1.420877) (xy -6.079066 1.591733) + (xy -5.908012 1.687696) (xy -5.768555 1.63019) (xy -5.718099 1.533763) (xy -5.613565 1.414546) + (xy -5.368973 1.306206) (xy -5.140893 1.240937) (xy -4.851955 1.171824) (xy -4.676694 1.149327) + (xy -4.565394 1.175608) (xy -4.468336 1.252832) (xy -4.449843 1.271017) (xy -4.338189 1.48193) + (xy -4.295208 1.778327) (xy -4.318563 2.092898) (xy -4.405918 2.358337) (xy -4.491418 2.468905) + (xy -4.638202 2.665836) (xy -4.623949 2.857959) (xy -4.56486 2.936606) (xy -4.414643 2.996368) + (xy -4.251464 2.956924) (xy -4.153709 2.843006) (xy -4.148677 2.805292) (xy -4.116256 2.66035) + (xy -4.031437 2.415811) (xy -3.91817 2.137833) (xy -3.784575 1.85135) (xy -3.678589 1.690432) + (xy -3.571148 1.621077) (xy -3.465898 1.608666) (xy -3.337283 1.626621) (xy -3.24647 1.70544) + (xy -3.165577 1.882562) (xy -3.092227 2.11041) (xy -3.018068 2.406957) (xy -2.9817 2.660811) + (xy -2.986519 2.788852) (xy -2.967814 2.968704) (xy -2.843258 3.077427) (xy -2.671303 3.08486) + (xy -2.552944 3.012563) (xy -2.463307 2.875893) (xy -2.509946 2.726361) (xy -2.520488 2.709113) + (xy -2.573431 2.53132) (xy -2.608814 2.209271) (xy -2.624203 1.767369) (xy -2.624666 1.665787) + (xy -2.624666 0.789277) (xy -1.970276 -0.118391) (xy -1.731578 -0.452595) (xy -1.55286 -0.692516) + (xy -1.422511 -0.828275) (xy -1.328915 -0.849992) (xy -1.260462 -0.747787) (xy -1.205538 -0.511781) + (xy -1.15253 -0.132094) (xy -1.089825 0.401154) (xy -1.059842 0.656166) (xy -1.003816 1.100655) + (xy -0.950156 1.478847) (xy -0.903417 1.762018) (xy -0.868156 1.921444) (xy -0.855276 1.945973) + (xy -0.77981 1.89135) (xy -0.598866 1.739745) (xy -0.332103 1.508256) (xy 0.000818 1.21398) + (xy 0.380239 0.874015) (xy 0.45877 0.803132) (xy 0.842573 0.458076) (xy 1.181285 0.156974) + (xy 1.455877 -0.083538) (xy 1.647316 -0.246823) (xy 1.736573 -0.316246) (xy 1.740554 -0.317341) + (xy 1.742207 -0.230037) (xy 1.733942 -0.004692) (xy 1.717208 0.327785) (xy 1.693456 0.736484) + (xy 1.683933 0.889) (xy 1.660198 1.345361) (xy 1.650815 1.778933) (xy 1.65695 2.227835) + (xy 1.679767 2.730189) (xy 1.720432 3.324116) (xy 1.780111 4.047739) (xy 1.780676 4.05425) + (xy 1.828135 4.613729) (xy 1.86837 5.114142) (xy 1.899657 5.531778) (xy 1.920272 5.842928) + (xy 1.928489 6.023881) (xy 1.926587 6.060301) (xy 1.847266 6.031503) (xy 1.649779 5.933955) + (xy 1.363159 5.782622) (xy 1.016435 5.592466) (xy 0.986118 5.575549) (xy 0.636329 5.383178) + (xy 0.344837 5.228696) (xy 0.140462 5.126955) (xy 0.052021 5.092809) (xy 0.050775 5.093497) + (xy -0.084486 5.265183) (xy -0.297331 5.519122) (xy -0.565672 5.830555) (xy -0.867421 6.174721) + (xy -1.180491 6.526861) (xy -1.482793 6.862215) (xy -1.75224 7.156024) (xy -1.966744 7.383528) + (xy -2.104217 7.519968) (xy -2.137516 7.546491) (xy -2.426226 7.678799) (xy -2.762183 7.799976) + (xy -3.099463 7.897437) (xy -3.392138 7.958596) (xy -3.594284 7.970865) (xy -3.640942 7.958519) + (xy -3.807467 7.944113) (xy -3.933264 8.046007) (xy -3.962151 8.211873) (xy -3.951489 8.247772) + (xy -3.891739 8.310323) (xy -3.752101 8.338704) (xy -3.498886 8.336639) (xy -3.277501 8.322266) + (xy -2.956151 8.300904) (xy -2.764697 8.303008) (xy -2.664348 8.33728) (xy -2.61631 8.412421) + (xy -2.598038 8.474684) (xy -2.591908 8.662391) (xy -2.681429 8.871965) (xy -2.882455 9.131414) + (xy -3.09796 9.357649) (xy -3.290062 9.593732) (xy -3.348354 9.773902) (xy -3.271731 9.881951) + (xy -3.135324 9.906) (xy -2.990623 9.846983) (xy -2.963182 9.757833) (xy -2.891514 9.617542) + (xy -2.712054 9.456806) (xy -2.477753 9.308432) (xy -2.24156 9.205227) (xy -2.056426 9.179999) + (xy -2.037813 9.184488) (xy -1.903603 9.302147) (xy -1.788074 9.526172) (xy -1.71083 9.793598) + (xy -1.691474 10.041462) (xy -1.728163 10.179053) (xy -1.768266 10.342283) (xy -1.718071 10.423129) + (xy -1.565487 10.486942) (xy -1.427232 10.42145) (xy -1.363442 10.260369) (xy -1.364419 10.224846) + (xy -1.371645 10.027713) (xy -1.37114 9.745478) (xy -1.367834 9.598375) (xy -1.347171 9.328831) + (xy -1.295538 9.184657) (xy -1.196962 9.122553) (xy -1.191779 9.121153) (xy -1.04141 9.159003) + (xy -0.853374 9.307554) (xy -0.665819 9.526094) (xy -0.516892 9.773913) (xy -0.470429 9.890996) + (xy -0.367123 10.041468) (xy -0.226426 10.059102) (xy -0.070309 9.982436) (xy -0.017853 9.852691) + (xy -0.083045 9.732959) (xy -0.147127 9.701381) (xy -0.244094 9.600287) (xy -0.363217 9.37669) + (xy -0.489137 9.073214) (xy -0.606496 8.732482) (xy -0.699935 8.397117) (xy -0.754096 8.109741) + (xy -0.761648 7.995958) (xy -0.708977 7.783194) (xy -0.558471 7.462639) (xy -0.320743 7.056549) + (xy -0.291795 7.010859) (xy 0.177706 6.274718) (xy 1.083686 6.748646) (xy 1.440256 6.936849) + (xy 1.74175 7.099134) (xy 1.956427 7.218197) (xy 2.052542 7.276736) (xy 2.052596 7.276782) + (xy 2.071864 7.378344) (xy 2.075562 7.611689) (xy 2.064035 7.940014) (xy 2.043409 8.255007) + (xy 2.014001 8.680171) (xy 2.006037 8.979515) (xy 2.022315 9.195521) (xy 2.065631 9.370673) + (xy 2.126787 9.521345) (xy 2.226646 9.802804) (xy 2.280965 10.075418) (xy 2.284141 10.132625) + (xy 2.326472 10.353958) (xy 2.419538 10.428958) (xy 2.508462 10.513964) (xy 2.645849 10.725041) + (xy 2.813924 11.032423) (xy 2.966776 11.345333) (xy 3.224719 11.864203) (xy 3.447046 12.219994) + (xy 3.644604 12.412461) (xy 3.828238 12.441361) (xy 4.008792 12.306448)) (layer B.Mask) (width 0.01)) + ) + + (module "Dane:big gecko" (layer F.Cu) (tedit 0) (tstamp 5F815764) + (at 124.46 116.84) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 4.008792 -12.306448) (xy 4.197112 -12.00748) (xy 4.404044 -11.54421) (xy 4.495193 -11.310908) + (xy 4.645632 -10.936371) (xy 4.784941 -10.627718) (xy 4.898265 -10.415388) (xy 4.970751 -10.329822) + (xy 4.974167 -10.329363) (xy 5.050092 -10.252351) (xy 5.079949 -10.045593) (xy 5.08 -10.034713) + (xy 5.113317 -9.755915) (xy 5.195135 -9.454602) (xy 5.211393 -9.41171) (xy 5.267201 -9.250425) + (xy 5.296179 -9.086173) (xy 5.298526 -8.878855) (xy 5.274438 -8.588374) (xy 5.224113 -8.174631) + (xy 5.217722 -8.125525) (xy 5.092658 -7.167724) (xy 6.032483 -5.933362) (xy 6.332372 -5.539501) + (xy 6.595504 -5.193938) (xy 6.805253 -4.918506) (xy 6.944992 -4.735039) (xy 6.997831 -4.665712) + (xy 7.091364 -4.66575) (xy 7.304027 -4.711479) (xy 7.595899 -4.790485) (xy 7.927058 -4.890351) + (xy 8.257583 -4.998662) (xy 8.547553 -5.103002) (xy 8.757046 -5.190955) (xy 8.83584 -5.237342) + (xy 8.974014 -5.408051) (xy 9.138994 -5.68053) (xy 9.305645 -6.003434) (xy 9.44883 -6.325416) + (xy 9.543412 -6.595131) (xy 9.567334 -6.731543) (xy 9.621743 -6.920752) (xy 9.750929 -7.012322) + (xy 9.903831 -6.975306) (xy 9.930738 -6.951796) (xy 9.984745 -6.830536) (xy 9.925047 -6.687702) + (xy 9.863269 -6.505829) (xy 9.82615 -6.236452) (xy 9.821334 -6.102854) (xy 9.846313 -5.810759) + (xy 9.931342 -5.650976) (xy 10.091553 -5.620288) (xy 10.342079 -5.715478) (xy 10.678968 -5.920542) + (xy 10.977005 -6.115371) (xy 11.166712 -6.22205) (xy 11.278384 -6.249676) (xy 11.342316 -6.207344) + (xy 11.378883 -6.130693) (xy 11.390757 -5.94518) (xy 11.262293 -5.850421) (xy 11.178118 -5.842) + (xy 11.028157 -5.774518) (xy 10.845381 -5.606436) (xy 10.671308 -5.389302) (xy 10.547456 -5.174661) + (xy 10.514483 -5.018067) (xy 10.603837 -4.893628) (xy 10.791938 -4.759518) (xy 11.022617 -4.643398) + (xy 11.239706 -4.572926) (xy 11.387038 -4.575764) (xy 11.398102 -4.582931) (xy 11.543923 -4.621711) + (xy 11.695131 -4.571846) (xy 11.767317 -4.462096) (xy 11.76737 -4.457108) (xy 11.711584 -4.258201) + (xy 11.571384 -4.188517) (xy 11.446334 -4.224592) (xy 11.232943 -4.292421) (xy 10.961049 -4.320264) + (xy 10.686957 -4.310168) (xy 10.466973 -4.264179) (xy 10.357659 -4.185027) (xy 10.385497 -4.056494) + (xy 10.506628 -3.868428) (xy 10.680968 -3.665621) (xy 10.868434 -3.492869) (xy 11.028942 -3.394964) + (xy 11.072072 -3.386666) (xy 11.156678 -3.328096) (xy 11.159805 -3.196456) (xy 11.096428 -3.057855) + (xy 10.981522 -2.978401) (xy 10.979499 -2.978001) (xy 10.831494 -3.019731) (xy 10.781916 -3.114629) + (xy 10.687751 -3.22331) (xy 10.475353 -3.370838) (xy 10.185155 -3.536905) (xy 9.85759 -3.701206) + (xy 9.533091 -3.843434) (xy 9.25209 -3.943281) (xy 9.057977 -3.980444) (xy 8.900327 -3.96853) + (xy 8.612074 -3.935059) (xy 8.2299 -3.884706) (xy 7.790492 -3.822147) (xy 7.638629 -3.799537) + (xy 7.20791 -3.737089) (xy 6.841258 -3.688476) (xy 6.568964 -3.657362) (xy 6.421322 -3.647409) + (xy 6.403881 -3.65026) (xy 6.352335 -3.730308) (xy 6.228652 -3.927343) (xy 6.049727 -4.214317) + (xy 5.832458 -4.564178) (xy 5.760223 -4.680749) (xy 5.535213 -5.0386) (xy 5.342323 -5.335072) + (xy 5.198334 -5.545152) (xy 5.120027 -5.643829) (xy 5.11146 -5.647682) (xy 5.108142 -5.558319) + (xy 5.114837 -5.322827) (xy 5.130465 -4.964044) (xy 5.153947 -4.50481) (xy 5.184204 -3.967966) + (xy 5.214635 -3.464599) (xy 5.348626 -1.312333) (xy 4.494901 0.325997) (xy 4.247641 0.809688) + (xy 4.033833 1.245714) (xy 3.864036 1.611031) (xy 3.748813 1.882597) (xy 3.698722 2.03737) + (xy 3.699431 2.061664) (xy 3.764335 2.155813) (xy 3.914025 2.36587) (xy 4.133465 2.67096) + (xy 4.407619 3.050208) (xy 4.72145 3.482739) (xy 4.886202 3.709242) (xy 5.211588 4.158048) + (xy 5.501956 4.562034) (xy 5.742876 4.900838) (xy 5.919918 5.154098) (xy 6.018652 5.301451) + (xy 6.034192 5.329213) (xy 5.974578 5.3972) (xy 5.796802 5.549089) (xy 5.520049 5.769738) + (xy 5.163506 6.044007) (xy 4.746359 6.356755) (xy 4.529667 6.516513) (xy 4.087721 6.842454) + (xy 3.694126 7.136281) (xy 3.368695 7.38291) (xy 3.131242 7.567258) (xy 3.001582 7.674241) + (xy 2.983499 7.693548) (xy 3.031808 7.781953) (xy 3.189871 7.923749) (xy 3.418502 8.091759) + (xy 3.678515 8.258807) (xy 3.930726 8.397718) (xy 4.106334 8.472264) (xy 4.412245 8.532817) + (xy 4.852633 8.562141) (xy 5.291667 8.561172) (xy 5.699381 8.544809) (xy 5.975175 8.517608) + (xy 6.156416 8.472635) (xy 6.280471 8.402956) (xy 6.318106 8.370696) (xy 6.455348 8.26034) + (xy 6.550458 8.26669) (xy 6.640475 8.345903) (xy 6.73397 8.503449) (xy 6.735869 8.611508) + (xy 6.693626 8.741251) (xy 6.688667 8.769925) (xy 6.61488 8.794702) (xy 6.436877 8.805327) + (xy 6.431852 8.805334) (xy 6.209851 8.843847) (xy 5.922339 8.942397) (xy 5.749288 9.021077) + (xy 5.503488 9.156939) (xy 5.380292 9.266966) (xy 5.345425 9.389048) (xy 5.349936 9.462532) + (xy 5.404373 9.617435) (xy 5.549696 9.76466) (xy 5.818351 9.936095) (xy 5.849987 9.953969) + (xy 6.135973 10.104049) (xy 6.394482 10.222203) (xy 6.539148 10.273783) (xy 6.740576 10.381449) + (xy 6.823204 10.546402) (xy 6.764427 10.721065) (xy 6.598243 10.825684) (xy 6.423925 10.808936) + (xy 6.310694 10.677535) (xy 6.31054 10.677053) (xy 6.2296 10.573265) (xy 6.041563 10.490123) + (xy 5.715668 10.414131) (xy 5.70793 10.412666) (xy 5.408003 10.360645) (xy 5.227642 10.348569) + (xy 5.120999 10.380156) (xy 5.042228 10.459119) (xy 5.036122 10.467114) (xy 4.956084 10.596938) + (xy 4.920577 10.745522) (xy 4.925177 10.962647) (xy 4.963532 11.284063) (xy 5.024702 11.554672) + (xy 5.1229 11.688914) (xy 5.175385 11.711335) (xy 5.284364 11.775531) (xy 5.274491 11.913776) + (xy 5.26147 11.951289) (xy 5.136793 12.13149) (xy 4.97723 12.180574) (xy 4.834055 12.097138) + (xy 4.77239 11.964663) (xy 4.703558 11.749624) (xy 4.593307 11.462588) (xy 4.521332 11.292838) + (xy 4.376632 11.014322) (xy 4.236003 10.865797) (xy 4.11272 10.817832) (xy 3.992927 10.807882) + (xy 3.909496 10.856272) (xy 3.837014 10.996375) (xy 3.750065 11.261568) (xy 3.733853 11.315367) + (xy 3.656769 11.620774) (xy 3.615975 11.883137) (xy 3.618542 12.031873) (xy 3.604244 12.217563) + (xy 3.486621 12.329447) (xy 3.322945 12.347405) (xy 3.170487 12.251316) (xy 3.137425 12.200891) + (xy 3.102392 12.038553) (xy 3.185683 11.929135) (xy 3.245412 11.854815) (xy 3.279239 11.731973) + (xy 3.289678 11.527733) (xy 3.279244 11.209225) (xy 3.262465 10.925411) (xy 3.23909 10.590975) + (xy 3.208115 10.322389) (xy 3.155655 10.091708) (xy 3.067826 9.87099) (xy 2.930743 9.632288) + (xy 2.73052 9.34766) (xy 2.453274 8.989161) (xy 2.085118 8.528847) (xy 2.04986 8.484966) + (xy 1.838623 8.230376) (xy 1.677213 8.033819) (xy 1.573738 7.874506) (xy 1.536304 7.731646) + (xy 1.573018 7.584448) (xy 1.691989 7.412123) (xy 1.901321 7.193879) (xy 2.209124 6.908926) + (xy 2.623503 6.536474) (xy 2.910989 6.276605) (xy 4.086311 5.208104) (xy 3.385888 4.551385) + (xy 3.102975 4.290276) (xy 2.865272 4.078676) (xy 2.69948 3.939842) (xy 2.633899 3.896326) + (xy 2.57027 3.964205) (xy 2.439322 4.146134) (xy 2.262183 4.411767) (xy 2.119776 4.634828) + (xy 1.726054 5.188633) (xy 1.228388 5.777403) (xy 0.67124 6.354557) (xy 0.099071 6.873513) + (xy -0.351238 7.22374) (xy -0.816039 7.519737) (xy -1.372154 7.82248) (xy -1.962521 8.104647) + (xy -2.530077 8.338915) (xy -3.005666 8.494765) (xy -3.577315 8.618661) (xy -4.222851 8.712809) + (xy -4.87654 8.770592) (xy -5.472646 8.785393) (xy -5.760882 8.772109) (xy -6.773518 8.605423) + (xy -7.750544 8.280201) (xy -8.678015 7.805848) (xy -9.541983 7.191771) (xy -10.328505 6.447374) + (xy -11.023634 5.582064) (xy -11.423444 4.953) (xy -11.618595 4.614334) (xy -11.383689 4.910667) + (xy -11.097038 5.242669) (xy -10.728255 5.627146) (xy -10.314829 6.028936) (xy -9.894248 6.412875) + (xy -9.504001 6.743799) (xy -9.181575 6.986544) (xy -9.144 7.011478) (xy -8.301169 7.471008) + (xy -7.413523 7.792745) (xy -6.506325 7.972352) (xy -5.604838 8.005491) (xy -4.734323 7.887822) + (xy -4.4603 7.815795) (xy -3.928496 7.625735) (xy -3.326712 7.358476) (xy -2.716103 7.043948) + (xy -2.157827 6.712081) (xy -2.024415 6.623671) (xy -1.568021 6.291266) (xy -1.159217 5.94097) + (xy -0.77772 5.54859) (xy -0.403251 5.089936) (xy -0.015528 4.540817) (xy 0.405731 3.877043) + (xy 0.721031 3.348967) (xy 1.214673 2.506933) (xy 0.416836 1.766246) (xy 0.118329 1.497962) + (xy -0.132987 1.288836) (xy -0.313654 1.157147) (xy -0.400215 1.121172) (xy -0.404075 1.126613) + (xy -0.420423 1.245302) (xy -0.448572 1.497282) (xy -0.484767 1.847228) (xy -0.52525 2.259812) + (xy -0.531075 2.320866) (xy -0.635 3.414065) (xy -1.993674 2.10384) (xy -2.453761 1.663339) + (xy -2.814034 1.327474) (xy -3.093861 1.080596) (xy -3.312614 0.907056) (xy -3.489664 0.791204) + (xy -3.644379 0.717392) (xy -3.754993 0.680882) (xy -4.059333 0.627232) (xy -4.436269 0.605791) + (xy -4.839055 0.613764) (xy -5.220949 0.648357) (xy -5.535206 0.706776) (xy -5.735081 0.786228) + (xy -5.752868 0.800293) (xy -5.890426 0.884312) (xy -6.026935 0.833959) (xy -6.047621 0.819224) + (xy -6.165791 0.658346) (xy -6.147055 0.49585) (xy -6.008391 0.390139) (xy -5.918991 0.376733) + (xy -5.719942 0.341037) (xy -5.451712 0.25496) (xy -5.170139 0.141382) (xy -4.931064 0.023183) + (xy -4.790326 -0.076757) (xy -4.780521 -0.089756) (xy -4.744706 -0.290207) (xy -4.876575 -0.502113) + (xy -5.174969 -0.723995) (xy -5.352301 -0.821142) (xy -5.640886 -0.963725) (xy -5.885397 -1.076887) + (xy -6.0325 -1.135985) (xy -6.153923 -1.244416) (xy -6.170799 -1.420877) (xy -6.079066 -1.591733) + (xy -5.908012 -1.687696) (xy -5.768555 -1.63019) (xy -5.718099 -1.533763) (xy -5.613565 -1.414546) + (xy -5.368973 -1.306206) (xy -5.140893 -1.240937) (xy -4.851955 -1.171824) (xy -4.676694 -1.149327) + (xy -4.565394 -1.175608) (xy -4.468336 -1.252832) (xy -4.449843 -1.271017) (xy -4.338189 -1.48193) + (xy -4.295208 -1.778327) (xy -4.318563 -2.092898) (xy -4.405918 -2.358337) (xy -4.491418 -2.468905) + (xy -4.638202 -2.665836) (xy -4.623949 -2.857959) (xy -4.56486 -2.936606) (xy -4.414643 -2.996368) + (xy -4.251464 -2.956924) (xy -4.153709 -2.843006) (xy -4.148677 -2.805292) (xy -4.116256 -2.66035) + (xy -4.031437 -2.415811) (xy -3.91817 -2.137833) (xy -3.784575 -1.85135) (xy -3.678589 -1.690432) + (xy -3.571148 -1.621077) (xy -3.465898 -1.608666) (xy -3.337283 -1.626621) (xy -3.24647 -1.70544) + (xy -3.165577 -1.882562) (xy -3.092227 -2.11041) (xy -3.018068 -2.406957) (xy -2.9817 -2.660811) + (xy -2.986519 -2.788852) (xy -2.967814 -2.968704) (xy -2.843258 -3.077427) (xy -2.671303 -3.08486) + (xy -2.552944 -3.012563) (xy -2.463307 -2.875893) (xy -2.509946 -2.726361) (xy -2.520488 -2.709113) + (xy -2.573431 -2.53132) (xy -2.608814 -2.209271) (xy -2.624203 -1.767369) (xy -2.624666 -1.665787) + (xy -2.624666 -0.789277) (xy -1.970276 0.118391) (xy -1.731578 0.452595) (xy -1.55286 0.692516) + (xy -1.422511 0.828275) (xy -1.328915 0.849992) (xy -1.260462 0.747787) (xy -1.205538 0.511781) + (xy -1.15253 0.132094) (xy -1.089825 -0.401154) (xy -1.059842 -0.656166) (xy -1.003816 -1.100655) + (xy -0.950156 -1.478847) (xy -0.903417 -1.762018) (xy -0.868156 -1.921444) (xy -0.855276 -1.945973) + (xy -0.77981 -1.89135) (xy -0.598866 -1.739745) (xy -0.332103 -1.508256) (xy 0.000818 -1.21398) + (xy 0.380239 -0.874015) (xy 0.45877 -0.803132) (xy 0.842573 -0.458076) (xy 1.181285 -0.156974) + (xy 1.455877 0.083538) (xy 1.647316 0.246823) (xy 1.736573 0.316246) (xy 1.740554 0.317341) + (xy 1.742207 0.230037) (xy 1.733942 0.004692) (xy 1.717208 -0.327785) (xy 1.693456 -0.736484) + (xy 1.683933 -0.889) (xy 1.660198 -1.345361) (xy 1.650815 -1.778933) (xy 1.65695 -2.227835) + (xy 1.679767 -2.730189) (xy 1.720432 -3.324116) (xy 1.780111 -4.047739) (xy 1.780676 -4.05425) + (xy 1.828135 -4.613729) (xy 1.86837 -5.114142) (xy 1.899657 -5.531778) (xy 1.920272 -5.842928) + (xy 1.928489 -6.023881) (xy 1.926587 -6.060301) (xy 1.847266 -6.031503) (xy 1.649779 -5.933955) + (xy 1.363159 -5.782622) (xy 1.016435 -5.592466) (xy 0.986118 -5.575549) (xy 0.636329 -5.383178) + (xy 0.344837 -5.228696) (xy 0.140462 -5.126955) (xy 0.052021 -5.092809) (xy 0.050775 -5.093497) + (xy -0.084486 -5.265183) (xy -0.297331 -5.519122) (xy -0.565672 -5.830555) (xy -0.867421 -6.174721) + (xy -1.180491 -6.526861) (xy -1.482793 -6.862215) (xy -1.75224 -7.156024) (xy -1.966744 -7.383528) + (xy -2.104217 -7.519968) (xy -2.137516 -7.546491) (xy -2.426226 -7.678799) (xy -2.762183 -7.799976) + (xy -3.099463 -7.897437) (xy -3.392138 -7.958596) (xy -3.594284 -7.970865) (xy -3.640942 -7.958519) + (xy -3.807467 -7.944113) (xy -3.933264 -8.046007) (xy -3.962151 -8.211873) (xy -3.951489 -8.247772) + (xy -3.891739 -8.310323) (xy -3.752101 -8.338704) (xy -3.498886 -8.336639) (xy -3.277501 -8.322266) + (xy -2.956151 -8.300904) (xy -2.764697 -8.303008) (xy -2.664348 -8.33728) (xy -2.61631 -8.412421) + (xy -2.598038 -8.474684) (xy -2.591908 -8.662391) (xy -2.681429 -8.871965) (xy -2.882455 -9.131414) + (xy -3.09796 -9.357649) (xy -3.290062 -9.593732) (xy -3.348354 -9.773902) (xy -3.271731 -9.881951) + (xy -3.135324 -9.906) (xy -2.990623 -9.846983) (xy -2.963182 -9.757833) (xy -2.891514 -9.617542) + (xy -2.712054 -9.456806) (xy -2.477753 -9.308432) (xy -2.24156 -9.205227) (xy -2.056426 -9.179999) + (xy -2.037813 -9.184488) (xy -1.903603 -9.302147) (xy -1.788074 -9.526172) (xy -1.71083 -9.793598) + (xy -1.691474 -10.041462) (xy -1.728163 -10.179053) (xy -1.768266 -10.342283) (xy -1.718071 -10.423129) + (xy -1.565487 -10.486942) (xy -1.427232 -10.42145) (xy -1.363442 -10.260369) (xy -1.364419 -10.224846) + (xy -1.371645 -10.027713) (xy -1.37114 -9.745478) (xy -1.367834 -9.598375) (xy -1.347171 -9.328831) + (xy -1.295538 -9.184657) (xy -1.196962 -9.122553) (xy -1.191779 -9.121153) (xy -1.04141 -9.159003) + (xy -0.853374 -9.307554) (xy -0.665819 -9.526094) (xy -0.516892 -9.773913) (xy -0.470429 -9.890996) + (xy -0.367123 -10.041468) (xy -0.226426 -10.059102) (xy -0.070309 -9.982436) (xy -0.017853 -9.852691) + (xy -0.083045 -9.732959) (xy -0.147127 -9.701381) (xy -0.244094 -9.600287) (xy -0.363217 -9.37669) + (xy -0.489137 -9.073214) (xy -0.606496 -8.732482) (xy -0.699935 -8.397117) (xy -0.754096 -8.109741) + (xy -0.761648 -7.995958) (xy -0.708977 -7.783194) (xy -0.558471 -7.462639) (xy -0.320743 -7.056549) + (xy -0.291795 -7.010859) (xy 0.177706 -6.274718) (xy 1.083686 -6.748646) (xy 1.440256 -6.936849) + (xy 1.74175 -7.099134) (xy 1.956427 -7.218197) (xy 2.052542 -7.276736) (xy 2.052596 -7.276782) + (xy 2.071864 -7.378344) (xy 2.075562 -7.611689) (xy 2.064035 -7.940014) (xy 2.043409 -8.255007) + (xy 2.014001 -8.680171) (xy 2.006037 -8.979515) (xy 2.022315 -9.195521) (xy 2.065631 -9.370673) + (xy 2.126787 -9.521345) (xy 2.226646 -9.802804) (xy 2.280965 -10.075418) (xy 2.284141 -10.132625) + (xy 2.326472 -10.353958) (xy 2.419538 -10.428958) (xy 2.508462 -10.513964) (xy 2.645849 -10.725041) + (xy 2.813924 -11.032423) (xy 2.966776 -11.345333) (xy 3.224719 -11.864203) (xy 3.447046 -12.219994) + (xy 3.644604 -12.412461) (xy 3.828238 -12.441361) (xy 4.008792 -12.306448)) (layer F.Mask) (width 0.01)) + ) + + (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F80C59F) + (at 187.96 130.81) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5F809D2B) + (at 215.9 114.3) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5F809D2B) + (at 213.36 52.07) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5F809D2B) + (at 97.79 133.35) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5F809D2B) + (at 99.06 46.99) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5F80C27C) + (at 92.225 94.175) + (path /5B74CE27) + (fp_text reference TH1 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BFE) (tstamp 5F80C2B6) + (at 206.9 100.7) + (path /5B74D88C) + (fp_text reference TH6 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.175 -0.025 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F8059EF) (tstamp 5F80C399) + (at 103.725 119.675 90) + (path /5B74D98F) + (fp_text reference TH7 (at 0 -2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0 0 180) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BD0) (tstamp 5F80C31A) + (at 130.75 98.25) + (path /5B74D78B) + (fp_text reference TH5 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5F80C278) + (at 107.725 94.175) + (path /5B74D0C7) + (fp_text reference TH2 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5F80C1E3) + (at 130.7 57.75) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805C11) (tstamp 5F80C1BE) + (at 206.95 62.45) + (path /5B74D1C0) + (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (gr_text "Original Sofle design by Josef Adamacik" (at 119.105 48.585) (layer B.SilkS) (tstamp 5F8157CD) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 121.355 46.915) (layer B.SilkS) (tstamp 5F8157CC) + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 121.355 48.335) (layer F.SilkS) (tstamp 5F80C5B4) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "Original Sofle design by Josef Adamacik" (at 119.105 46.665) (layer F.SilkS) (tstamp 5F80C5B0) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_text "Sofle RGB v1.0, Dane Evans" (at 201.285 127.895 21) (layer B.Cu) (tstamp 5F80C599) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Sofle RGB v1.0, Dane Evans" (at 201.975 127.925 21) (layer F.Cu) (tstamp 5F80C3DA) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_line (start 225.586871 44.256466) (end 225.751621 44.3706) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B20D)) + (gr_line (start 89.000257 115.075) (end 88.998857 39.152435) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B201)) + (gr_line (start 225.893321 44.510582) (end 226.008881 44.672807) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B1F9)) + (gr_line (start 149.725 35.675) (end 171.675 35.675) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B1A6)) + (gr_line (start 89.702436 38.090945) (end 89.91868 38.023815) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B19D)) + (gr_line (start 225.751621 44.3706) (end 225.893321 44.510582) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B198)) + (gr_line (start 89.91868 38.023815) (end 90.150853 38.000405) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B193)) + (gr_line (start 138.879128 134.675) (end 94.625 147.425) (layer Edge.Cuts) (width 0.1) (tstamp 5F80B16F)) + (gr_line (start 89.336259 38.337831) (end 89.506752 38.19716) (layer Edge.Cuts) (width 0.1) (tstamp 5F80ABA5)) + (gr_line (start 82.825 127.575) (end 82.925 127.075) (layer Edge.Cuts) (width 0.1) (tstamp 5F80ABA4)) + (gr_line (start 89.19559 38.508327) (end 89.336259 38.337831) (layer Edge.Cuts) (width 0.1) (tstamp 5F80ABA2)) + (gr_line (start 83.025 129.075) (end 82.875 128.575) (layer Edge.Cuts) (width 0.1) (tstamp 5F80ABA1)) + (gr_line (start 138.879128 134.675) (end 188.225 134.675) (layer Edge.Cuts) (width 0.1) (tstamp 5F80ABA0)) + (gr_line (start 149.725 35.675) (end 90.150853 38.000405) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB9F)) + (gr_line (start 226.095281 44.853672) (end 226.149381 45.049571) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB9D)) + (gr_line (start 89.506752 38.19716) (end 89.702436 38.090945) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB9C)) + (gr_line (start 89.089377 38.704014) (end 89.19559 38.508327) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB9B)) + (gr_line (start 82.925 127.075) (end 88.725 116.325) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB9A)) + (gr_line (start 226.149381 45.049571) (end 226.168181 45.256902) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB99)) + (gr_line (start 226.168181 45.256902) (end 226.195181 120.175) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB98)) + (gr_line (start 225.200441 44.120146) (end 225.402111 44.171776) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB97)) + (gr_line (start 93.275 146.875) (end 93.625 147.175) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB92)) + (gr_line (start 82.825 127.975) (end 82.825 127.575) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB8D)) + (gr_line (start 88.925 115.725) (end 88.725 116.325) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB8B)) + (gr_line (start 88.998857 39.152435) (end 89.022257 38.920261) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB8A)) + (gr_line (start 89.022257 38.920261) (end 89.089377 38.704014) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB86)) + (gr_line (start 226.195181 120.175) (end 188.225 134.675) (layer Edge.Cuts) (width 0.15) (tstamp 5F80AB85)) + (gr_line (start 225.402111 44.171776) (end 225.586871 44.256466) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB84)) + (gr_line (start 93.625 147.175) (end 94.075 147.325) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB83)) + (gr_line (start 82.875 128.575) (end 82.825 127.975) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB80)) + (gr_line (start 94.075 147.325) (end 94.625 147.425) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB7F)) + (gr_line (start 89.000257 115.075) (end 88.925 115.725) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB7E)) + (gr_line (start 171.675 35.675) (end 225.200441 44.120146) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB61)) + (gr_line (start 93.275 146.875) (end 83.025 129.075) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB60)) + (gr_line (start 226.008881 44.672807) (end 226.095281 44.853672) (layer Edge.Cuts) (width 0.1) (tstamp 5F80AB5F)) + + (zone (net 0) (net_name "") (layer F.Cu) (tstamp 5F80B225) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508)) + (polygon + (pts + (xy 81.675 127.875) (xy 93.625 148.325) (xy 138.725 135.625) (xy 157.975 135.725) (xy 188.175 135.525) + (xy 226.625 122.175) (xy 226.725 43.475) (xy 172.425 34.975) (xy 88.175 37.275) (xy 88.525 115.675) + ) + ) + (filled_polygon + (pts + (xy 225.061807 44.791746) (xy 225.172617 44.820115) (xy 225.246481 44.853972) (xy 225.312585 44.899767) (xy 225.369771 44.956261) + (xy 225.416436 45.021768) (xy 225.451105 45.094343) (xy 225.472732 45.172657) (xy 225.483192 45.288012) (xy 225.510002 119.676646) + (xy 212.918396 124.485112) (xy 212.160322 122.510262) (xy 190.782665 130.716376) (xy 191.526529 132.654208) (xy 188.02858 133.99) + (xy 138.883838 133.99) (xy 138.821265 133.989123) (xy 138.783284 133.996126) (xy 138.744845 133.999912) (xy 138.684927 134.018088) + (xy 94.589605 146.722335) (xy 94.245432 146.659758) (xy 93.968912 146.567584) (xy 93.80999 146.431366) (xy 86.064697 132.981003) + (xy 94.83 132.981003) (xy 94.83 133.568997) (xy 94.944712 134.145692) (xy 95.169727 134.688928) (xy 95.496399 135.177826) + (xy 95.912174 135.593601) (xy 96.401072 135.920273) (xy 96.944308 136.145288) (xy 97.521003 136.26) (xy 98.108997 136.26) + (xy 98.685692 136.145288) (xy 99.228928 135.920273) (xy 99.717826 135.593601) (xy 100.133601 135.177826) (xy 100.460273 134.688928) + (xy 100.685288 134.145692) (xy 100.8 133.568997) (xy 100.8 132.981003) (xy 100.685288 132.404308) (xy 100.460273 131.861072) + (xy 100.133601 131.372174) (xy 99.717826 130.956399) (xy 99.228928 130.629727) (xy 98.685692 130.404712) (xy 98.108997 130.29) + (xy 97.521003 130.29) (xy 96.944308 130.404712) (xy 96.401072 130.629727) (xy 95.912174 130.956399) (xy 95.496399 131.372174) + (xy 95.169727 131.861072) (xy 94.944712 132.404308) (xy 94.83 132.981003) (xy 86.064697 132.981003) (xy 83.658274 128.802044) + (xy 83.551687 128.446756) (xy 83.51 127.946515) (xy 83.51 127.642828) (xy 83.576575 127.309954) (xy 87.854521 119.381003) + (xy 100.74 119.381003) (xy 100.74 119.968997) (xy 100.854712 120.545692) (xy 101.079727 121.088928) (xy 101.406399 121.577826) + (xy 101.822174 121.993601) (xy 102.311072 122.320273) (xy 102.854308 122.545288) (xy 103.431003 122.66) (xy 104.018997 122.66) + (xy 104.595692 122.545288) (xy 105.138928 122.320273) (xy 105.627826 121.993601) (xy 106.043601 121.577826) (xy 106.370273 121.088928) + (xy 106.595288 120.545692) (xy 106.71 119.968997) (xy 106.71 119.381003) (xy 106.595288 118.804308) (xy 106.370273 118.261072) + (xy 106.043601 117.772174) (xy 105.627826 117.356399) (xy 105.138928 117.029727) (xy 104.595692 116.804712) (xy 104.018997 116.69) + (xy 103.431003 116.69) (xy 102.854308 116.804712) (xy 102.311072 117.029727) (xy 101.822174 117.356399) (xy 101.406399 117.772174) + (xy 101.079727 118.261072) (xy 100.854712 118.804308) (xy 100.74 119.381003) (xy 87.854521 119.381003) (xy 89.308074 116.686918) + (xy 89.32298 116.665873) (xy 89.340021 116.627706) (xy 89.343829 116.620648) (xy 89.35376 116.596935) (xy 89.364207 116.573536) + (xy 89.366735 116.565952) (xy 89.382891 116.527374) (xy 89.388024 116.502087) (xy 89.56531 115.97023) (xy 89.580164 115.936034) + (xy 89.593713 115.873522) (xy 89.607908 115.81109) (xy 89.608923 115.773817) (xy 89.673633 115.214922) (xy 89.675347 115.20927) + (xy 89.681379 115.148019) (xy 89.684581 115.12036) (xy 89.684682 115.114478) (xy 89.685257 115.108634) (xy 89.685256 115.080836) + (xy 89.686309 115.019252) (xy 89.685255 115.013437) (xy 89.685236 113.931003) (xy 212.94 113.931003) (xy 212.94 114.518997) + (xy 213.054712 115.095692) (xy 213.279727 115.638928) (xy 213.606399 116.127826) (xy 214.022174 116.543601) (xy 214.511072 116.870273) + (xy 215.054308 117.095288) (xy 215.631003 117.21) (xy 216.218997 117.21) (xy 216.795692 117.095288) (xy 217.338928 116.870273) + (xy 217.827826 116.543601) (xy 218.243601 116.127826) (xy 218.570273 115.638928) (xy 218.795288 115.095692) (xy 218.91 114.518997) + (xy 218.91 113.931003) (xy 218.795288 113.354308) (xy 218.570273 112.811072) (xy 218.243601 112.322174) (xy 217.827826 111.906399) + (xy 217.338928 111.579727) (xy 216.795692 111.354712) (xy 216.218997 111.24) (xy 215.631003 111.24) (xy 215.054308 111.354712) + (xy 214.511072 111.579727) (xy 214.022174 111.906399) (xy 213.606399 112.322174) (xy 213.279727 112.811072) (xy 213.054712 113.354308) + (xy 212.94 113.931003) (xy 89.685236 113.931003) (xy 89.68494 97.881003) (xy 127.74 97.881003) (xy 127.74 98.468997) + (xy 127.854712 99.045692) (xy 128.079727 99.588928) (xy 128.406399 100.077826) (xy 128.822174 100.493601) (xy 129.311072 100.820273) + (xy 129.854308 101.045288) (xy 130.431003 101.16) (xy 131.018997 101.16) (xy 131.595692 101.045288) (xy 132.138928 100.820273) + (xy 132.627826 100.493601) (xy 132.740424 100.381003) (xy 203.74 100.381003) (xy 203.74 100.968997) (xy 203.854712 101.545692) + (xy 204.079727 102.088928) (xy 204.406399 102.577826) (xy 204.822174 102.993601) (xy 205.311072 103.320273) (xy 205.854308 103.545288) + (xy 206.431003 103.66) (xy 207.018997 103.66) (xy 207.595692 103.545288) (xy 208.138928 103.320273) (xy 208.627826 102.993601) + (xy 209.043601 102.577826) (xy 209.370273 102.088928) (xy 209.595288 101.545692) (xy 209.71 100.968997) (xy 209.71 100.381003) + (xy 209.595288 99.804308) (xy 209.370273 99.261072) (xy 209.043601 98.772174) (xy 208.627826 98.356399) (xy 208.138928 98.029727) + (xy 207.595692 97.804712) (xy 207.018997 97.69) (xy 206.431003 97.69) (xy 205.854308 97.804712) (xy 205.311072 98.029727) + (xy 204.822174 98.356399) (xy 204.406399 98.772174) (xy 204.079727 99.261072) (xy 203.854712 99.804308) (xy 203.74 100.381003) + (xy 132.740424 100.381003) (xy 133.043601 100.077826) (xy 133.370273 99.588928) (xy 133.595288 99.045692) (xy 133.71 98.468997) + (xy 133.71 97.881003) (xy 133.595288 97.304308) (xy 133.370273 96.761072) (xy 133.043601 96.272174) (xy 132.627826 95.856399) + (xy 132.138928 95.529727) (xy 131.595692 95.304712) (xy 131.018997 95.19) (xy 130.431003 95.19) (xy 129.854308 95.304712) + (xy 129.311072 95.529727) (xy 128.822174 95.856399) (xy 128.406399 96.272174) (xy 128.079727 96.761072) (xy 127.854712 97.304308) + (xy 127.74 97.881003) (xy 89.68494 97.881003) (xy 89.684885 94.911545) (xy 89.691261 94.943601) (xy 89.889893 95.423141) + (xy 90.178262 95.854715) (xy 90.545285 96.221738) (xy 90.976859 96.510107) (xy 91.456399 96.708739) (xy 91.965475 96.81) + (xy 92.484525 96.81) (xy 92.993601 96.708739) (xy 93.473141 96.510107) (xy 93.904715 96.221738) (xy 94.271738 95.854715) + (xy 94.560107 95.423141) (xy 94.758739 94.943601) (xy 94.86 94.434525) (xy 94.86 93.915475) (xy 105.09 93.915475) + (xy 105.09 94.434525) (xy 105.191261 94.943601) (xy 105.389893 95.423141) (xy 105.678262 95.854715) (xy 106.045285 96.221738) + (xy 106.476859 96.510107) (xy 106.956399 96.708739) (xy 107.465475 96.81) (xy 107.984525 96.81) (xy 108.493601 96.708739) + (xy 108.973141 96.510107) (xy 109.404715 96.221738) (xy 109.771738 95.854715) (xy 110.060107 95.423141) (xy 110.258739 94.943601) + (xy 110.36 94.434525) (xy 110.36 93.915475) (xy 110.258739 93.406399) (xy 110.060107 92.926859) (xy 109.771738 92.495285) + (xy 109.404715 92.128262) (xy 108.973141 91.839893) (xy 108.493601 91.641261) (xy 107.984525 91.54) (xy 107.465475 91.54) + (xy 106.956399 91.641261) (xy 106.476859 91.839893) (xy 106.045285 92.128262) (xy 105.678262 92.495285) (xy 105.389893 92.926859) + (xy 105.191261 93.406399) (xy 105.09 93.915475) (xy 94.86 93.915475) (xy 94.758739 93.406399) (xy 94.560107 92.926859) + (xy 94.271738 92.495285) (xy 93.904715 92.128262) (xy 93.473141 91.839893) (xy 92.993601 91.641261) (xy 92.484525 91.54) + (xy 91.965475 91.54) (xy 91.456399 91.641261) (xy 90.976859 91.839893) (xy 90.545285 92.128262) (xy 90.178262 92.495285) + (xy 89.889893 92.926859) (xy 89.691261 93.406399) (xy 89.684857 93.438592) (xy 89.684277 61.881003) (xy 203.74 61.881003) + (xy 203.74 62.468997) (xy 203.854712 63.045692) (xy 204.079727 63.588928) (xy 204.406399 64.077826) (xy 204.822174 64.493601) + (xy 205.311072 64.820273) (xy 205.854308 65.045288) (xy 206.431003 65.16) (xy 207.018997 65.16) (xy 207.595692 65.045288) + (xy 208.138928 64.820273) (xy 208.627826 64.493601) (xy 209.043601 64.077826) (xy 209.370273 63.588928) (xy 209.595288 63.045692) + (xy 209.71 62.468997) (xy 209.71 61.881003) (xy 209.595288 61.304308) (xy 209.370273 60.761072) (xy 209.043601 60.272174) + (xy 208.627826 59.856399) (xy 208.138928 59.529727) (xy 207.595692 59.304712) (xy 207.018997 59.19) (xy 206.431003 59.19) + (xy 205.854308 59.304712) (xy 205.311072 59.529727) (xy 204.822174 59.856399) (xy 204.406399 60.272174) (xy 204.079727 60.761072) + (xy 203.854712 61.304308) (xy 203.74 61.881003) (xy 89.684277 61.881003) (xy 89.684194 57.381003) (xy 127.74 57.381003) + (xy 127.74 57.968997) (xy 127.854712 58.545692) (xy 128.079727 59.088928) (xy 128.406399 59.577826) (xy 128.822174 59.993601) + (xy 129.311072 60.320273) (xy 129.854308 60.545288) (xy 130.431003 60.66) (xy 131.018997 60.66) (xy 131.595692 60.545288) + (xy 132.138928 60.320273) (xy 132.627826 59.993601) (xy 133.043601 59.577826) (xy 133.370273 59.088928) (xy 133.595288 58.545692) + (xy 133.71 57.968997) (xy 133.71 57.381003) (xy 133.595288 56.804308) (xy 133.370273 56.261072) (xy 133.043601 55.772174) + (xy 132.627826 55.356399) (xy 132.138928 55.029727) (xy 131.595692 54.804712) (xy 131.018997 54.69) (xy 130.431003 54.69) + (xy 129.854308 54.804712) (xy 129.311072 55.029727) (xy 128.822174 55.356399) (xy 128.406399 55.772174) (xy 128.079727 56.261072) + (xy 127.854712 56.804308) (xy 127.74 57.381003) (xy 89.684194 57.381003) (xy 89.684089 51.701003) (xy 210.4 51.701003) + (xy 210.4 52.288997) (xy 210.514712 52.865692) (xy 210.739727 53.408928) (xy 211.066399 53.897826) (xy 211.482174 54.313601) + (xy 211.971072 54.640273) (xy 212.514308 54.865288) (xy 213.091003 54.98) (xy 213.678997 54.98) (xy 214.255692 54.865288) + (xy 214.798928 54.640273) (xy 215.287826 54.313601) (xy 215.703601 53.897826) (xy 216.030273 53.408928) (xy 216.255288 52.865692) + (xy 216.37 52.288997) (xy 216.37 51.701003) (xy 216.255288 51.124308) (xy 216.030273 50.581072) (xy 215.703601 50.092174) + (xy 215.287826 49.676399) (xy 214.798928 49.349727) (xy 214.255692 49.124712) (xy 213.678997 49.01) (xy 213.091003 49.01) + (xy 212.514308 49.124712) (xy 211.971072 49.349727) (xy 211.482174 49.676399) (xy 211.066399 50.092174) (xy 210.739727 50.581072) + (xy 210.514712 51.124308) (xy 210.4 51.701003) (xy 89.684089 51.701003) (xy 89.683995 46.621003) (xy 96.1 46.621003) + (xy 96.1 47.208997) (xy 96.214712 47.785692) (xy 96.439727 48.328928) (xy 96.766399 48.817826) (xy 97.182174 49.233601) + (xy 97.671072 49.560273) (xy 98.214308 49.785288) (xy 98.791003 49.9) (xy 99.378997 49.9) (xy 99.955692 49.785288) + (xy 100.498928 49.560273) (xy 100.987826 49.233601) (xy 101.403601 48.817826) (xy 101.730273 48.328928) (xy 101.955288 47.785692) + (xy 102.07 47.208997) (xy 102.07 46.621003) (xy 101.955288 46.044308) (xy 101.730273 45.501072) (xy 101.403601 45.012174) + (xy 100.987826 44.596399) (xy 100.498928 44.269727) (xy 99.955692 44.044712) (xy 99.378997 43.93) (xy 98.791003 43.93) + (xy 98.214308 44.044712) (xy 97.671072 44.269727) (xy 97.182174 44.596399) (xy 96.766399 45.012174) (xy 96.439727 45.501072) + (xy 96.214712 46.044308) (xy 96.1 46.621003) (xy 89.683995 46.621003) (xy 89.683857 39.186863) (xy 89.696894 39.057509) + (xy 89.723593 38.971493) (xy 89.766067 38.893238) (xy 89.822851 38.824414) (xy 89.89167 38.767633) (xy 89.969936 38.72515) + (xy 90.05596 38.698445) (xy 90.198606 38.684063) (xy 149.738379 36.36) (xy 171.621299 36.36) + ) + ) + ) +) diff --git a/Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.pro b/Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.pro new file mode 100644 index 00000000..3f0da368 --- /dev/null +++ b/Sofle_RGB_v3/Case/PCBBottom/SofleKeyboardBottomPlate.pro @@ -0,0 +1,61 @@ + +update=2018 March 15, Thursday 14:41:19 +version=1 +last_client=kicad +[pcbnew] +version=1 +LastNetListRead= +UseCmpFile=1 +PadDrill=0.600000000000 +PadDrillOvalY=0.600000000000 +PadSizeH=1.500000000000 +PadSizeV=1.500000000000 +PcbTextSizeV=1.500000000000 +PcbTextSizeH=1.500000000000 +PcbTextThickness=0.300000000000 +ModuleTextSizeV=1.000000000000 +ModuleTextSizeH=1.000000000000 +ModuleTextSizeThickness=0.150000000000 +SolderMaskClearance=0.000000000000 +SolderMaskMinWidth=0.000000000000 +DrawSegmentWidth=0.200000000000 +BoardOutlineThickness=0.100000000000 +ModuleOutlineThickness=0.150000000000 +[cvpcb] +version=1 +NetIExt=net +[general] +version=1 +[eeschema] +version=1 +LibDir= +[eeschema/libraries] +LibName1=power +LibName2=device +LibName3=transistors +LibName4=conn +LibName5=linear +LibName6=regul +LibName7=74xx +LibName8=cmos4000 +LibName9=adc-dac +LibName10=memory +LibName11=xilinx +LibName12=microcontrollers +LibName13=dsp +LibName14=microchip +LibName15=analog_switches +LibName16=motorola +LibName17=texas +LibName18=intel +LibName19=audio +LibName20=interface +LibName21=digital-audio +LibName22=philips +LibName23=display +LibName24=cypress +LibName25=siliconi +LibName26=opto +LibName27=atmel +LibName28=contrib +LibName29=valves diff --git a/Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.kicad_pcb b/Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.kicad_pcb new file mode 100644 index 00000000..bab5aafb --- /dev/null +++ b/Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.kicad_pcb @@ -0,0 +1,1706 @@ +(kicad_pcb (version 20171130) (host pcbnew "(5.1.6)-1") + + (general + (thickness 1.6) + (drawings 166) + (tracks 0) + (zones 0) + (modules 9) + (nets 1) + ) + + (page A4) + (layers + (0 F.Cu signal) + (31 B.Cu signal) + (32 B.Adhes user hide) + (33 F.Adhes user hide) + (34 B.Paste user hide) + (35 F.Paste user hide) + (36 B.SilkS user) + (37 F.SilkS user) + (38 B.Mask user) + (39 F.Mask user) + (40 Dwgs.User user) + (41 Cmts.User user) + (42 Eco1.User user) + (43 Eco2.User user) + (44 Edge.Cuts user) + (45 Margin user) + (46 B.CrtYd user) + (47 F.CrtYd user) + (48 B.Fab user) + (49 F.Fab user) + ) + + (setup + (last_trace_width 0.25) + (trace_clearance 0.2) + (zone_clearance 0.508) + (zone_45_only no) + (trace_min 0.2) + (via_size 0.6) + (via_drill 0.4) + (via_min_size 0.4) + (via_min_drill 0.3) + (uvia_size 0.3) + (uvia_drill 0.1) + (uvias_allowed no) + (uvia_min_size 0.2) + (uvia_min_drill 0.1) + (edge_width 0.15) + (segment_width 0.2) + (pcb_text_width 0.3) + (pcb_text_size 1.5 1.5) + (mod_edge_width 0.15) + (mod_text_size 1 1) + (mod_text_width 0.15) + (pad_size 4.7 4.7) + (pad_drill 2.2) + (pad_to_mask_clearance 0.2) + (aux_axis_origin 0 0) + (grid_origin 111.995 97.8) + (visible_elements 7FFFFFFF) + (pcbplotparams + (layerselection 0x010f0_ffffffff) + (usegerberextensions false) + (usegerberattributes false) + (usegerberadvancedattributes false) + (creategerberjobfile false) + (excludeedgelayer true) + (linewidth 0.100000) + (plotframeref false) + (viasonmask false) + (mode 1) + (useauxorigin false) + (hpglpennumber 1) + (hpglpenspeed 20) + (hpglpendiameter 15.000000) + (psnegative false) + (psa4output false) + (plotreference true) + (plotvalue true) + (plotinvisibletext false) + (padsonsilk false) + (subtractmaskfromsilk false) + (outputformat 1) + (mirror false) + (drillshape 0) + (scaleselection 1) + (outputdirectory "gerber/")) + ) + + (net 0 "") + + (net_class Default "This is the default net class." + (clearance 0.2) + (trace_width 0.25) + (via_dia 0.6) + (via_drill 0.4) + (uvia_dia 0.3) + (uvia_drill 0.1) + ) + + (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F80B7BF) + (at 94.495 117.3) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) + ) + + (module dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F80B7AB) + (at 95.495 117.3 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) + (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) + (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) + (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) + (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) + (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) + (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) + (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) + (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) + (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) + (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) + (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) + (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) + (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) + (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) + (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) + (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) + (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) + (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) + (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) + (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) + (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) + (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) + (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) + (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) + (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) + (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) + (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) + (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) + (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) + (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) + (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) + (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) + (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) + (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) + (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) + (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) + (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) + (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) + (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) + (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) + (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) + (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) + (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) + (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) + (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) + (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) + (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) + (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) + (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) + (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) + (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) + (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) + (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) + (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) + (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) + (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) + (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) + (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) + (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) + (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) + (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) + (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) + (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) + (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) + (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) + (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) + (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) + (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) + (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) + (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) + (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) + (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) + (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) + (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) + (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) + (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) + (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) + (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) + (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) + (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) + (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) + (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) + (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) + (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) + (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) + (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) + (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) + (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) + (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) + (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) + (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) + (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) + (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) + (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) + (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) + (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) + (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) + (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) + (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) + (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) + (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) + (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) + (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) + (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) + (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) + (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) + (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) + (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) + (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) + (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) + (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) + (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) + (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) + (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) + (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) + (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) + (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) + (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) + (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) + (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) + (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) + (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) + (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) + (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) + (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) + (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) + (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) + (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) + (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) + (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) + (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) + (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) + (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) + (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) + (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) + (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) + (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) + (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) + (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) + (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) + (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) + (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) + (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) + (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) + (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) + (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) + (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) + (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) + (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) + (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) + (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) + ) + + (module dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F80E41E) + (at 192.995 126.195 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) + (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) + (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) + (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) + (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) + (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) + (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) + (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) + (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) + (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) + (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) + (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) + (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) + (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) + (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) + (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) + (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) + (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) + (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) + (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) + (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) + (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) + (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) + (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) + (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) + (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) + (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) + (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) + (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) + (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) + (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) + (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) + (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) + (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) + (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) + (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) + (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) + (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) + (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) + (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) + (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) + (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) + (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) + (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) + (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) + (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) + (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) + (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) + (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) + (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) + (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) + (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) + (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) + (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) + (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) + (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) + (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) + (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) + (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) + (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) + (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) + (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) + (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) + (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) + (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) + (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) + (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) + (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) + (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) + (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) + (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) + (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) + (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) + (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) + (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) + (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) + (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) + (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) + (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) + (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) + (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) + (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) + (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) + (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) + (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) + (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) + (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) + (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) + (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) + (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) + (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) + (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) + (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) + (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) + (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) + (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) + (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) + (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) + (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) + (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) + (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) + (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) + (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) + (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) + (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) + (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) + (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) + (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) + (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) + (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) + (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) + (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) + (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) + (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) + (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) + (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) + (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) + (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) + (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) + (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) + (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) + (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) + (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) + (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) + (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) + (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) + (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) + (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) + (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) + (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) + (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) + (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) + (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) + (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) + (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) + (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) + (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) + (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) + (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) + (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) + (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) + (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) + (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) + (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) + (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) + (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) + (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) + (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) + (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) + (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) + (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) + (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5FDAFEE7) (tstamp 5F80E3D9) + (at 103.995 120.445 90) + (path /5B74D98F) + (fp_text reference TH7 (at 0 -2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0 0 180) (size 4.7 4.7) (drill 2.2) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5FDAFEDF) (tstamp 5F80E35A) + (at 131.02 99.02) + (path /5B74D78B) + (fp_text reference TH5 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.025 -0.075 90) (size 4.7 4.7) (drill 2.2) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5FDAFEF8) (tstamp 5F80E2ED) + (at 207.17 101.47) + (path /5B74D88C) + (fp_text reference TH6 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.175 -0.025 90) (size 4.7 4.7) (drill 2.2) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5FDAFEC8) (tstamp 5F80E208) + (at 130.97 58.52) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 2.2) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5FDAFEEF) (tstamp 5F80E1DA) + (at 207.22 63.22) + (path /5B74D1C0) + (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 2.2) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F80D23E) + (at 192.245 126.195) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) + ) + + (gr_text "Sofle RGB - Dane Evans\n" (at 101.495 114.3) (layer B.SilkS) (tstamp 5FDB0119) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Sofle RGB - Dane Evans\n" (at 100.995 114.3) (layer F.SilkS) (tstamp 5FDB0111) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_line (start 112.995 38) (end 113.395 37.9) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 112.695 38.1) (end 112.995 38) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 112.495 38.2) (end 112.695 38.1) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 112.295 38.4) (end 112.495 38.2) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 112.095 38.7) (end 112.295 38.4) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 111.995 39.045) (end 112.095 38.7) (layer Edge.Cuts) (width 0.15)) + (gr_arc (start 110.995 96.8) (end 110.995 97.8) (angle -90) (layer Edge.Cuts) (width 0.15)) + (gr_arc (start 90.3 98.8) (end 90.3 97.8) (angle -90) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 108.795 111.945) (end 108.795 105.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B735)) + (gr_line (start 93.195 111.945) (end 108.795 111.945) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 93.195 99.945) (end 93.195 111.945) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 108.795 99.945) (end 93.195 99.945) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 108.795 105.945) (end 108.795 99.945) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 88.142822 132.282822) (end 100.267178 125.282822) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 95.142822 144.407178) (end 88.142822 132.282822) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 100.267178 125.282822) (end 107.267178 137.407178) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 107.267178 137.407178) (end 95.142822 144.407178) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 113.645253 138.418214) (end 110.021786 124.895253) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 127.168214 134.794747) (end 113.645253 138.418214) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 110.021786 124.895253) (end 123.544747 121.271786) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 123.544747 121.271786) (end 127.168214 134.794747) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 223.695 46.845) (end 223.695 60.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 209.695 46.845) (end 223.695 46.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 223.695 60.845) (end 209.695 60.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 209.695 60.845) (end 209.695 46.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 223.695 65.745) (end 223.695 79.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 209.695 65.745) (end 223.695 65.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 223.695 79.745) (end 209.695 79.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 209.695 79.745) (end 209.695 65.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 223.695 84.945) (end 223.695 98.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 209.695 84.945) (end 223.695 84.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 223.695 98.945) (end 209.695 98.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 209.695 98.945) (end 209.695 84.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 223.745 103.945) (end 223.745 117.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 209.745 103.945) (end 223.745 103.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 223.745 117.945) (end 209.745 117.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 209.745 117.945) (end 209.745 103.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 204.695 103.945) (end 204.695 117.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 190.695 103.945) (end 204.695 103.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 204.695 117.945) (end 190.695 117.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 190.695 117.945) (end 190.695 103.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 204.695 84.945) (end 204.695 98.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 190.695 84.945) (end 204.695 84.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 204.695 98.945) (end 190.695 98.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 190.695 98.945) (end 190.695 84.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 204.695 65.745) (end 204.695 79.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 190.695 65.745) (end 204.695 65.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 204.695 79.745) (end 190.695 79.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 190.695 79.745) (end 190.695 65.745) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 204.695 46.845) (end 204.695 60.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 190.695 46.845) (end 204.695 46.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 204.695 60.845) (end 190.695 60.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 190.695 60.845) (end 190.695 46.845) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 185.595 118.245) (end 185.595 132.245) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 171.595 118.245) (end 185.595 118.245) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 185.595 132.245) (end 171.595 132.245) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 171.595 132.245) (end 171.595 118.245) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 185.595 99.145) (end 185.595 113.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 171.595 99.145) (end 185.595 99.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 185.595 113.145) (end 171.595 113.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 171.595 113.145) (end 171.595 99.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 185.595 80.045) (end 185.595 94.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 171.595 80.045) (end 185.595 80.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 185.595 94.045) (end 171.595 94.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 171.595 94.045) (end 171.595 80.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 185.595 60.985) (end 185.595 74.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 171.595 60.985) (end 185.595 60.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 185.595 74.985) (end 171.595 74.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 171.595 74.985) (end 171.595 60.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 185.595 41.985) (end 185.595 55.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 171.595 41.985) (end 185.595 41.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 185.595 55.985) (end 171.595 55.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 171.595 55.985) (end 171.595 41.985) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 166.595 115.735) (end 166.595 129.735) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 152.595 115.735) (end 166.595 115.735) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 166.595 129.735) (end 152.595 129.735) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 152.595 129.735) (end 152.595 115.735) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 166.595 96.635) (end 166.595 110.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 152.595 96.635) (end 166.595 96.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 166.595 110.635) (end 152.595 110.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 152.595 110.635) (end 152.595 96.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 166.595 77.635) (end 166.595 91.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 152.595 77.635) (end 166.595 77.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 166.595 91.635) (end 152.595 91.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 152.595 91.635) (end 152.595 77.635) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 166.595 58.535) (end 166.595 72.535) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 152.595 58.535) (end 166.595 58.535) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 166.595 72.535) (end 152.595 72.535) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 152.595 72.535) (end 152.595 58.535) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 166.595 39.445) (end 166.595 53.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 152.595 39.445) (end 166.595 39.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 166.595 53.445) (end 152.595 53.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 152.595 53.445) (end 152.595 39.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 147.495 118.145) (end 147.495 132.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 133.495 118.145) (end 147.495 118.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 147.495 132.145) (end 133.495 132.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 133.495 132.145) (end 133.495 118.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 147.495 99.145) (end 147.495 113.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 133.495 99.145) (end 147.495 99.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 147.495 113.145) (end 133.495 113.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 133.495 113.145) (end 133.495 99.145) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 147.495 80.045) (end 147.495 94.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 133.495 80.045) (end 147.495 80.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 147.495 94.045) (end 133.495 94.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 133.495 94.045) (end 133.495 80.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 147.495 61.045) (end 147.495 75.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 133.495 61.045) (end 147.495 61.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 147.495 75.045) (end 133.495 75.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 133.495 75.045) (end 133.495 61.045) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 147.495 41.945) (end 147.495 55.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 133.495 41.945) (end 147.495 41.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 147.495 55.945) (end 133.495 55.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 133.495 55.945) (end 133.495 41.945) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 128.495 101.545) (end 128.495 115.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 114.495 101.545) (end 128.495 101.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 128.495 115.545) (end 114.495 115.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 114.495 115.545) (end 114.495 101.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 128.495 82.545) (end 128.495 96.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 114.495 82.545) (end 128.495 82.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 128.495 96.545) (end 114.495 96.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 114.495 96.545) (end 114.495 82.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 128.495 63.545) (end 128.495 77.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 114.495 63.545) (end 128.495 63.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 128.495 77.545) (end 114.495 77.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 114.495 77.545) (end 114.495 63.545) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 128.495 44.445) (end 128.495 58.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B534)) + (gr_line (start 114.495 44.445) (end 128.495 44.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B533)) + (gr_line (start 128.495 58.445) (end 114.495 58.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B532)) + (gr_line (start 114.495 58.445) (end 114.495 44.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80B531)) + (gr_line (start 111.995 96.8) (end 111.995 39.045) (layer Edge.Cuts) (width 0.15)) + (gr_line (start 90.3 97.8) (end 110.995 97.8) (layer Edge.Cuts) (width 0.15)) + (gr_text "Sofle RGB v1.1, Dane Evans" (at 202.245 128.695 21) (layer F.Cu) (tstamp 5F80E427) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_text "Sofle RGB v1.1, Dane Evans" (at 201.995 128.695 21) (layer B.Cu) (tstamp 5F80E422) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Original Sofle design by Josef Adamacik" (at 130.895 79.1 90) (layer F.Cu) (tstamp 5F80E41D) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_text "Original Sofle design by Josef Adamacik" (at 130.995 79.3 270) (layer B.Cu) (tstamp 5F80E41C) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 150.095 80.5 90) (layer F.Cu) (tstamp 5F80E41B) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 150.395 80.5 270) (layer B.Cu) (tstamp 5F80E41A) + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (gr_line (start 225.856871 45.026466) (end 226.021621 45.1406) (layer Edge.Cuts) (width 0.1) (tstamp 5F80D222)) + (gr_line (start 89.270257 115.845) (end 89.3 98.8) (layer Edge.Cuts) (width 0.1) (tstamp 5F80D216)) + (gr_line (start 226.163321 45.280582) (end 226.278881 45.442807) (layer Edge.Cuts) (width 0.1) (tstamp 5F80D20E)) + (gr_line (start 149.995 36.445) (end 171.945 36.445) (layer Edge.Cuts) (width 0.1) (tstamp 5F80D142)) + (gr_line (start 226.021621 45.1406) (end 226.163321 45.280582) (layer Edge.Cuts) (width 0.1) (tstamp 5F80D134)) + (gr_line (start 139.149128 135.445) (end 94.895 148.195) (layer Edge.Cuts) (width 0.1) (tstamp 5F80D10B)) + (gr_line (start 83.095 128.345) (end 83.195 127.845) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C604)) + (gr_line (start 83.295 129.845) (end 83.145 129.345) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C601)) + (gr_line (start 139.149128 135.445) (end 188.495 135.445) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C600)) + (gr_line (start 149.995 36.445) (end 113.395 37.9) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5FF)) + (gr_line (start 226.365281 45.623672) (end 226.419381 45.819571) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5FD)) + (gr_line (start 83.195 127.845) (end 88.995 117.095) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5FA)) + (gr_line (start 226.419381 45.819571) (end 226.438181 46.026902) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5F9)) + (gr_line (start 226.438181 46.026902) (end 226.465181 120.945) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5F8)) + (gr_line (start 225.470441 44.890146) (end 225.672111 44.941776) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5F7)) + (gr_line (start 93.545 147.645) (end 93.895 147.945) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5F2)) + (gr_line (start 83.095 128.745) (end 83.095 128.345) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5ED)) + (gr_line (start 89.195 116.495) (end 88.995 117.095) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5EB)) + (gr_line (start 226.465181 120.945) (end 188.495 135.445) (layer Edge.Cuts) (width 0.15) (tstamp 5F80C5E5)) + (gr_line (start 225.672111 44.941776) (end 225.856871 45.026466) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5E4)) + (gr_line (start 93.895 147.945) (end 94.345 148.095) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5E3)) + (gr_line (start 83.145 129.345) (end 83.095 128.745) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5E0)) + (gr_line (start 94.345 148.095) (end 94.895 148.195) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5DF)) + (gr_line (start 89.270257 115.845) (end 89.195 116.495) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5DE)) + (gr_line (start 171.945 36.445) (end 225.470441 44.890146) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5BB)) + (gr_line (start 93.545 147.645) (end 83.295 129.845) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5BA)) + (gr_line (start 226.278881 45.442807) (end 226.365281 45.623672) (layer Edge.Cuts) (width 0.1) (tstamp 5F80C5B9)) + + (zone (net 0) (net_name "") (layer F.Cu) (tstamp 5F80D23D) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508)) + (polygon + (pts + (xy 81.945 128.645) (xy 93.895 149.095) (xy 138.995 136.395) (xy 158.245 136.495) (xy 188.445 136.295) + (xy 226.895 122.945) (xy 226.995 44.245) (xy 172.695 35.745) (xy 88.445 38.045) (xy 88.795 116.445) + ) + ) + (filled_polygon + (pts + (xy 225.331807 45.561746) (xy 225.442617 45.590115) (xy 225.516481 45.623972) (xy 225.582585 45.669767) (xy 225.639771 45.726261) + (xy 225.686436 45.791768) (xy 225.721105 45.864343) (xy 225.742732 45.942657) (xy 225.753192 46.058012) (xy 225.780002 120.446646) + (xy 213.188396 125.255112) (xy 212.430322 123.280262) (xy 191.052665 131.486376) (xy 191.796529 133.424208) (xy 188.29858 134.76) + (xy 139.153838 134.76) (xy 139.091265 134.759123) (xy 139.053284 134.766126) (xy 139.014845 134.769912) (xy 138.954927 134.788088) + (xy 94.859605 147.492335) (xy 94.515432 147.429758) (xy 94.238912 147.337584) (xy 94.07999 147.201366) (xy 85.462387 132.236162) + (xy 87.430915 132.236162) (xy 87.435491 132.375943) (xy 87.467249 132.512148) (xy 87.52497 132.639539) (xy 87.545383 132.668025) + (xy 94.510511 144.731983) (xy 94.52497 144.763895) (xy 94.545377 144.792373) (xy 94.545382 144.792382) (xy 94.606432 144.877578) + (xy 94.676889 144.943567) (xy 94.708511 144.973184) (xy 94.753423 145.001112) (xy 94.827277 145.047038) (xy 94.958171 145.096303) + (xy 95.096161 145.119085) (xy 95.096162 145.119085) (xy 95.235943 145.114509) (xy 95.372148 145.082751) (xy 95.467617 145.039494) + (xy 95.467618 145.039494) (xy 95.499539 145.02503) (xy 95.528025 145.004617) (xy 107.591983 138.039489) (xy 107.623895 138.02503) + (xy 107.652373 138.004623) (xy 107.652382 138.004618) (xy 107.737578 137.943568) (xy 107.833183 137.84149) (xy 107.907038 137.722723) + (xy 107.956303 137.591829) (xy 107.979085 137.453839) (xy 107.974509 137.314057) (xy 107.942751 137.177852) (xy 107.942751 137.177851) + (xy 107.899494 137.082382) (xy 107.899491 137.082377) (xy 107.88503 137.050461) (xy 107.86462 137.021979) (xy 100.899493 124.958025) + (xy 100.892194 124.941914) (xy 109.309879 124.941914) (xy 109.332661 125.079903) (xy 109.345005 125.112701) (xy 112.950421 138.568296) + (xy 112.956128 138.602864) (xy 112.968469 138.635654) (xy 112.968472 138.635664) (xy 113.005392 138.733758) (xy 113.079247 138.852526) + (xy 113.174852 138.954603) (xy 113.288535 139.036067) (xy 113.415927 139.093787) (xy 113.55213 139.125545) (xy 113.691914 139.130122) + (xy 113.829903 139.107339) (xy 113.862704 139.094994) (xy 127.318294 135.48958) (xy 127.352864 135.483872) (xy 127.385657 135.47153) + (xy 127.385664 135.471528) (xy 127.483758 135.434608) (xy 127.602526 135.360753) (xy 127.704603 135.265148) (xy 127.786067 135.151465) + (xy 127.843787 135.024073) (xy 127.875545 134.88787) (xy 127.880122 134.748086) (xy 127.857339 134.610097) (xy 127.844995 134.577299) + (xy 124.239581 121.121716) (xy 124.233872 121.087136) (xy 124.184608 120.956242) (xy 124.110753 120.837474) (xy 124.015148 120.735398) + (xy 123.901465 120.653933) (xy 123.774073 120.596213) (xy 123.637869 120.564455) (xy 123.498086 120.559879) (xy 123.394674 120.576952) + (xy 123.394671 120.576953) (xy 123.360097 120.582661) (xy 123.327301 120.595005) (xy 109.871713 124.200419) (xy 109.837136 124.206128) + (xy 109.804336 124.218473) (xy 109.706242 124.255393) (xy 109.587475 124.329248) (xy 109.485398 124.424853) (xy 109.403933 124.538536) + (xy 109.346213 124.665928) (xy 109.314455 124.802131) (xy 109.309879 124.941914) (xy 100.892194 124.941914) (xy 100.88503 124.926105) + (xy 100.803567 124.812422) (xy 100.701489 124.716816) (xy 100.582722 124.642962) (xy 100.451828 124.593697) (xy 100.313838 124.570915) + (xy 100.174056 124.575491) (xy 100.037851 124.607249) (xy 99.942382 124.650506) (xy 99.942377 124.650509) (xy 99.910461 124.66497) + (xy 99.881979 124.68538) (xy 87.818025 131.650507) (xy 87.786105 131.66497) (xy 87.75762 131.685382) (xy 87.757618 131.685383) + (xy 87.672422 131.746433) (xy 87.576816 131.848511) (xy 87.502962 131.967278) (xy 87.453697 132.098172) (xy 87.430915 132.236162) + (xy 85.462387 132.236162) (xy 83.928274 129.572044) (xy 83.821687 129.216756) (xy 83.78 128.716515) (xy 83.78 128.412828) + (xy 83.846575 128.079954) (xy 88.124521 120.151003) (xy 101.01 120.151003) (xy 101.01 120.738997) (xy 101.124712 121.315692) + (xy 101.349727 121.858928) (xy 101.676399 122.347826) (xy 102.092174 122.763601) (xy 102.581072 123.090273) (xy 103.124308 123.315288) + (xy 103.701003 123.43) (xy 104.288997 123.43) (xy 104.865692 123.315288) (xy 105.408928 123.090273) (xy 105.897826 122.763601) + (xy 106.313601 122.347826) (xy 106.640273 121.858928) (xy 106.865288 121.315692) (xy 106.98 120.738997) (xy 106.98 120.151003) + (xy 106.865288 119.574308) (xy 106.640273 119.031072) (xy 106.313601 118.542174) (xy 105.916427 118.145) (xy 132.781565 118.145) + (xy 132.785001 118.179887) (xy 132.785 132.110123) (xy 132.781565 132.145) (xy 132.795273 132.284184) (xy 132.835872 132.41802) + (xy 132.9018 132.541363) (xy 132.990525 132.649475) (xy 133.098637 132.7382) (xy 133.22198 132.804128) (xy 133.355816 132.844727) + (xy 133.495 132.858435) (xy 133.529877 132.855) (xy 147.460123 132.855) (xy 147.495 132.858435) (xy 147.529877 132.855) + (xy 147.592545 132.848828) (xy 147.634184 132.844727) (xy 147.76802 132.804128) (xy 147.891363 132.7382) (xy 147.999475 132.649475) + (xy 148.0882 132.541363) (xy 148.154128 132.41802) (xy 148.194727 132.284184) (xy 148.205 132.179877) (xy 148.205 132.179876) + (xy 148.208435 132.145) (xy 148.205 132.110123) (xy 148.205 118.179877) (xy 148.208435 118.145) (xy 148.194727 118.005816) + (xy 148.154128 117.87198) (xy 148.0882 117.748637) (xy 147.999475 117.640525) (xy 147.891363 117.5518) (xy 147.76802 117.485872) + (xy 147.634184 117.445273) (xy 147.529877 117.435) (xy 147.495 117.431565) (xy 147.460123 117.435) (xy 133.529877 117.435) + (xy 133.495 117.431565) (xy 133.460123 117.435) (xy 133.355816 117.445273) (xy 133.22198 117.485872) (xy 133.098637 117.5518) + (xy 132.990525 117.640525) (xy 132.9018 117.748637) (xy 132.835872 117.87198) (xy 132.795273 118.005816) (xy 132.781565 118.145) + (xy 105.916427 118.145) (xy 105.897826 118.126399) (xy 105.408928 117.799727) (xy 104.865692 117.574712) (xy 104.288997 117.46) + (xy 103.701003 117.46) (xy 103.124308 117.574712) (xy 102.581072 117.799727) (xy 102.092174 118.126399) (xy 101.676399 118.542174) + (xy 101.349727 119.031072) (xy 101.124712 119.574308) (xy 101.01 120.151003) (xy 88.124521 120.151003) (xy 89.578074 117.456918) + (xy 89.59298 117.435873) (xy 89.610021 117.397706) (xy 89.613829 117.390648) (xy 89.62376 117.366935) (xy 89.634207 117.343536) + (xy 89.636735 117.335952) (xy 89.652891 117.297374) (xy 89.658024 117.272087) (xy 89.83531 116.74023) (xy 89.850164 116.706034) + (xy 89.863713 116.643522) (xy 89.877908 116.58109) (xy 89.878923 116.543817) (xy 89.943563 115.985526) (xy 89.945109 115.98046) + (xy 89.95131 115.918616) (xy 89.954581 115.89036) (xy 89.954671 115.885087) (xy 89.955197 115.879842) (xy 89.955247 115.851414) + (xy 89.956309 115.789252) (xy 89.955364 115.784038) (xy 89.983002 99.945) (xy 92.481565 99.945) (xy 92.485 99.979877) + (xy 92.485001 111.910113) (xy 92.481565 111.945) (xy 92.495273 112.084184) (xy 92.535872 112.21802) (xy 92.6018 112.341363) + (xy 92.690525 112.449475) (xy 92.798637 112.5382) (xy 92.92198 112.604128) (xy 93.055816 112.644727) (xy 93.160123 112.655) + (xy 93.195 112.658435) (xy 93.229877 112.655) (xy 108.760123 112.655) (xy 108.795 112.658435) (xy 108.829877 112.655) + (xy 108.934184 112.644727) (xy 109.06802 112.604128) (xy 109.191363 112.5382) (xy 109.299475 112.449475) (xy 109.3882 112.341363) + (xy 109.454128 112.21802) (xy 109.494727 112.084184) (xy 109.508435 111.945) (xy 109.505 111.910123) (xy 109.505 99.979877) + (xy 109.508435 99.945) (xy 109.494727 99.805816) (xy 109.454128 99.67198) (xy 109.3882 99.548637) (xy 109.299475 99.440525) + (xy 109.191363 99.3518) (xy 109.06802 99.285872) (xy 108.934184 99.245273) (xy 108.829877 99.235) (xy 108.795 99.231565) + (xy 108.760123 99.235) (xy 93.229877 99.235) (xy 93.195 99.231565) (xy 93.160123 99.235) (xy 93.055816 99.245273) + (xy 92.92198 99.285872) (xy 92.798637 99.3518) (xy 92.690525 99.440525) (xy 92.6018 99.548637) (xy 92.535872 99.67198) + (xy 92.495273 99.805816) (xy 92.481565 99.945) (xy 89.983002 99.945) (xy 89.984691 98.977395) (xy 90.005575 98.879143) + (xy 90.006611 98.869285) (xy 90.018863 98.744335) (xy 90.03503 98.690786) (xy 90.061288 98.641403) (xy 90.096641 98.598055) + (xy 90.13974 98.5624) (xy 90.188937 98.535799) (xy 90.242375 98.519258) (xy 90.330455 98.51) (xy 111.029877 98.51) + (xy 111.060222 98.507011) (xy 111.066332 98.507054) (xy 111.076198 98.506086) (xy 111.270295 98.485685) (xy 111.33331 98.47275) + (xy 111.39654 98.460688) (xy 111.40603 98.457823) (xy 111.592468 98.400111) (xy 111.651797 98.375171) (xy 111.711455 98.351068) + (xy 111.720208 98.346414) (xy 111.891885 98.253589) (xy 111.945198 98.217629) (xy 111.999083 98.182367) (xy 112.006765 98.176102) + (xy 112.157143 98.051698) (xy 112.20248 98.006043) (xy 112.248463 97.961013) (xy 112.254782 97.953375) (xy 112.378132 97.802133) + (xy 112.413757 97.748513) (xy 112.450099 97.695436) (xy 112.454814 97.686716) (xy 112.546439 97.514394) (xy 112.570951 97.454924) + (xy 112.596312 97.395752) (xy 112.599243 97.386282) (xy 112.655652 97.199446) (xy 112.668152 97.136316) (xy 112.68153 97.073377) + (xy 112.682566 97.063519) (xy 112.701611 96.869285) (xy 112.705 96.834877) (xy 112.705 82.545) (xy 113.781565 82.545) + (xy 113.785001 82.579887) (xy 113.785 96.510123) (xy 113.781565 96.545) (xy 113.795273 96.684184) (xy 113.835872 96.81802) + (xy 113.9018 96.941363) (xy 113.990525 97.049475) (xy 114.069533 97.114315) (xy 114.098637 97.1382) (xy 114.22198 97.204128) + (xy 114.355816 97.244727) (xy 114.495 97.258435) (xy 114.529877 97.255) (xy 128.460123 97.255) (xy 128.495 97.258435) + (xy 128.529877 97.255) (xy 128.534497 97.254545) (xy 128.349727 97.531072) (xy 128.124712 98.074308) (xy 128.01 98.651003) + (xy 128.01 99.238997) (xy 128.124712 99.815692) (xy 128.349727 100.358928) (xy 128.676399 100.847826) (xy 128.691116 100.862543) + (xy 128.634184 100.845273) (xy 128.529877 100.835) (xy 128.495 100.831565) (xy 128.460123 100.835) (xy 114.529877 100.835) + (xy 114.495 100.831565) (xy 114.460123 100.835) (xy 114.355816 100.845273) (xy 114.22198 100.885872) (xy 114.098637 100.9518) + (xy 113.990525 101.040525) (xy 113.9018 101.148637) (xy 113.835872 101.27198) (xy 113.795273 101.405816) (xy 113.781565 101.545) + (xy 113.785001 101.579887) (xy 113.785 115.510123) (xy 113.781565 115.545) (xy 113.795273 115.684184) (xy 113.835872 115.81802) + (xy 113.9018 115.941363) (xy 113.990525 116.049475) (xy 114.090306 116.131363) (xy 114.098637 116.1382) (xy 114.22198 116.204128) + (xy 114.355816 116.244727) (xy 114.495 116.258435) (xy 114.529877 116.255) (xy 128.460123 116.255) (xy 128.495 116.258435) + (xy 128.529877 116.255) (xy 128.634184 116.244727) (xy 128.76802 116.204128) (xy 128.891363 116.1382) (xy 128.999475 116.049475) + (xy 129.0882 115.941363) (xy 129.154128 115.81802) (xy 129.179312 115.735) (xy 151.881565 115.735) (xy 151.885001 115.769887) + (xy 151.885 129.700123) (xy 151.881565 129.735) (xy 151.895273 129.874184) (xy 151.935872 130.00802) (xy 152.0018 130.131363) + (xy 152.090525 130.239475) (xy 152.198637 130.3282) (xy 152.32198 130.394128) (xy 152.455816 130.434727) (xy 152.595 130.448435) + (xy 152.629877 130.445) (xy 166.560123 130.445) (xy 166.595 130.448435) (xy 166.629877 130.445) (xy 166.734184 130.434727) + (xy 166.86802 130.394128) (xy 166.991363 130.3282) (xy 167.099475 130.239475) (xy 167.1882 130.131363) (xy 167.254128 130.00802) + (xy 167.294727 129.874184) (xy 167.308435 129.735) (xy 167.305 129.700123) (xy 167.305 118.245) (xy 170.881565 118.245) + (xy 170.885001 118.279887) (xy 170.885 132.210123) (xy 170.881565 132.245) (xy 170.895273 132.384184) (xy 170.935872 132.51802) + (xy 171.0018 132.641363) (xy 171.090525 132.749475) (xy 171.198637 132.8382) (xy 171.32198 132.904128) (xy 171.455816 132.944727) + (xy 171.595 132.958435) (xy 171.629877 132.955) (xy 185.560123 132.955) (xy 185.595 132.958435) (xy 185.629877 132.955) + (xy 185.734184 132.944727) (xy 185.86802 132.904128) (xy 185.991363 132.8382) (xy 186.099475 132.749475) (xy 186.1882 132.641363) + (xy 186.254128 132.51802) (xy 186.294727 132.384184) (xy 186.308435 132.245) (xy 186.305 132.210123) (xy 186.305 118.279877) + (xy 186.308435 118.245) (xy 186.294727 118.105816) (xy 186.254128 117.97198) (xy 186.1882 117.848637) (xy 186.099475 117.740525) + (xy 185.991363 117.6518) (xy 185.86802 117.585872) (xy 185.734184 117.545273) (xy 185.629877 117.535) (xy 185.595 117.531565) + (xy 185.560123 117.535) (xy 171.629877 117.535) (xy 171.595 117.531565) (xy 171.560123 117.535) (xy 171.455816 117.545273) + (xy 171.32198 117.585872) (xy 171.198637 117.6518) (xy 171.090525 117.740525) (xy 171.0018 117.848637) (xy 170.935872 117.97198) + (xy 170.895273 118.105816) (xy 170.881565 118.245) (xy 167.305 118.245) (xy 167.305 115.769877) (xy 167.308435 115.735) + (xy 167.294727 115.595816) (xy 167.254128 115.46198) (xy 167.1882 115.338637) (xy 167.099475 115.230525) (xy 166.991363 115.1418) + (xy 166.86802 115.075872) (xy 166.734184 115.035273) (xy 166.629877 115.025) (xy 166.595 115.021565) (xy 166.560123 115.025) + (xy 152.629877 115.025) (xy 152.595 115.021565) (xy 152.560123 115.025) (xy 152.455816 115.035273) (xy 152.32198 115.075872) + (xy 152.198637 115.1418) (xy 152.090525 115.230525) (xy 152.0018 115.338637) (xy 151.935872 115.46198) (xy 151.895273 115.595816) + (xy 151.881565 115.735) (xy 129.179312 115.735) (xy 129.194727 115.684184) (xy 129.208435 115.545) (xy 129.205 115.510123) + (xy 129.205 101.579877) (xy 129.208435 101.545) (xy 129.194727 101.405816) (xy 129.16669 101.313391) (xy 129.581072 101.590273) + (xy 130.124308 101.815288) (xy 130.701003 101.93) (xy 131.288997 101.93) (xy 131.865692 101.815288) (xy 132.408928 101.590273) + (xy 132.785001 101.338989) (xy 132.785 113.110123) (xy 132.781565 113.145) (xy 132.795273 113.284184) (xy 132.835872 113.41802) + (xy 132.9018 113.541363) (xy 132.990525 113.649475) (xy 133.098637 113.7382) (xy 133.22198 113.804128) (xy 133.355816 113.844727) + (xy 133.495 113.858435) (xy 133.529877 113.855) (xy 147.460123 113.855) (xy 147.495 113.858435) (xy 147.529877 113.855) + (xy 147.634184 113.844727) (xy 147.76802 113.804128) (xy 147.891363 113.7382) (xy 147.999475 113.649475) (xy 148.0882 113.541363) + (xy 148.154128 113.41802) (xy 148.194727 113.284184) (xy 148.208435 113.145) (xy 148.205 113.110123) (xy 148.205 99.179877) + (xy 148.208435 99.145) (xy 148.194727 99.005816) (xy 148.154128 98.87198) (xy 148.0882 98.748637) (xy 147.999475 98.640525) + (xy 147.891363 98.5518) (xy 147.76802 98.485872) (xy 147.634184 98.445273) (xy 147.529877 98.435) (xy 147.495 98.431565) + (xy 147.460123 98.435) (xy 133.937034 98.435) (xy 133.865288 98.074308) (xy 133.640273 97.531072) (xy 133.313601 97.042174) + (xy 132.897826 96.626399) (xy 132.408928 96.299727) (xy 131.865692 96.074712) (xy 131.288997 95.96) (xy 130.701003 95.96) + (xy 130.124308 96.074712) (xy 129.581072 96.299727) (xy 129.208043 96.548977) (xy 129.208435 96.545) (xy 129.205 96.510123) + (xy 129.205 82.579877) (xy 129.208435 82.545) (xy 129.194727 82.405816) (xy 129.154128 82.27198) (xy 129.0882 82.148637) + (xy 128.999475 82.040525) (xy 128.891363 81.9518) (xy 128.76802 81.885872) (xy 128.634184 81.845273) (xy 128.529877 81.835) + (xy 128.495 81.831565) (xy 128.460123 81.835) (xy 114.529877 81.835) (xy 114.495 81.831565) (xy 114.460123 81.835) + (xy 114.355816 81.845273) (xy 114.22198 81.885872) (xy 114.098637 81.9518) (xy 113.990525 82.040525) (xy 113.9018 82.148637) + (xy 113.835872 82.27198) (xy 113.795273 82.405816) (xy 113.781565 82.545) (xy 112.705 82.545) (xy 112.705 63.545) + (xy 113.781565 63.545) (xy 113.785001 63.579887) (xy 113.785 77.510123) (xy 113.781565 77.545) (xy 113.795273 77.684184) + (xy 113.835872 77.81802) (xy 113.9018 77.941363) (xy 113.990525 78.049475) (xy 114.098637 78.1382) (xy 114.22198 78.204128) + (xy 114.355816 78.244727) (xy 114.495 78.258435) (xy 114.529877 78.255) (xy 128.460123 78.255) (xy 128.495 78.258435) + (xy 128.529877 78.255) (xy 128.634184 78.244727) (xy 128.76802 78.204128) (xy 128.891363 78.1382) (xy 128.999475 78.049475) + (xy 129.0882 77.941363) (xy 129.154128 77.81802) (xy 129.194727 77.684184) (xy 129.208435 77.545) (xy 129.205 77.510123) + (xy 129.205 63.579877) (xy 129.208435 63.545) (xy 129.194727 63.405816) (xy 129.154128 63.27198) (xy 129.0882 63.148637) + (xy 128.999475 63.040525) (xy 128.891363 62.9518) (xy 128.773515 62.888809) (xy 129.49 62.888809) (xy 129.49 95.31119) + (xy 132.46 95.31119) (xy 132.46 80.045) (xy 132.781565 80.045) (xy 132.785001 80.079887) (xy 132.785 94.010123) + (xy 132.781565 94.045) (xy 132.795273 94.184184) (xy 132.835872 94.31802) (xy 132.9018 94.441363) (xy 132.990525 94.549475) + (xy 133.098637 94.6382) (xy 133.22198 94.704128) (xy 133.355816 94.744727) (xy 133.495 94.758435) (xy 133.529877 94.755) + (xy 147.460123 94.755) (xy 147.495 94.758435) (xy 147.529877 94.755) (xy 147.634184 94.744727) (xy 147.76802 94.704128) + (xy 147.891363 94.6382) (xy 147.999475 94.549475) (xy 148.0882 94.441363) (xy 148.154128 94.31802) (xy 148.194727 94.184184) + (xy 148.208435 94.045) (xy 148.205 94.010123) (xy 148.205 80.079877) (xy 148.208435 80.045) (xy 148.194727 79.905816) + (xy 148.154128 79.77198) (xy 148.0882 79.648637) (xy 147.999475 79.540525) (xy 147.891363 79.4518) (xy 147.76802 79.385872) + (xy 147.634184 79.345273) (xy 147.529877 79.335) (xy 147.495 79.331565) (xy 147.460123 79.335) (xy 133.529877 79.335) + (xy 133.495 79.331565) (xy 133.460123 79.335) (xy 133.355816 79.345273) (xy 133.22198 79.385872) (xy 133.098637 79.4518) + (xy 132.990525 79.540525) (xy 132.9018 79.648637) (xy 132.835872 79.77198) (xy 132.795273 79.905816) (xy 132.781565 80.045) + (xy 132.46 80.045) (xy 132.46 62.888809) (xy 129.49 62.888809) (xy 128.773515 62.888809) (xy 128.76802 62.885872) + (xy 128.634184 62.845273) (xy 128.529877 62.835) (xy 128.495 62.831565) (xy 128.460123 62.835) (xy 114.529877 62.835) + (xy 114.495 62.831565) (xy 114.460123 62.835) (xy 114.355816 62.845273) (xy 114.22198 62.885872) (xy 114.098637 62.9518) + (xy 113.990525 63.040525) (xy 113.9018 63.148637) (xy 113.835872 63.27198) (xy 113.795273 63.405816) (xy 113.781565 63.545) + (xy 112.705 63.545) (xy 112.705 44.445) (xy 113.781565 44.445) (xy 113.785001 44.479887) (xy 113.785 58.410123) + (xy 113.781565 58.445) (xy 113.795273 58.584184) (xy 113.835872 58.71802) (xy 113.9018 58.841363) (xy 113.990525 58.949475) + (xy 114.098637 59.0382) (xy 114.22198 59.104128) (xy 114.355816 59.144727) (xy 114.495 59.158435) (xy 114.529877 59.155) + (xy 128.092748 59.155) (xy 128.124712 59.315692) (xy 128.349727 59.858928) (xy 128.676399 60.347826) (xy 129.092174 60.763601) + (xy 129.581072 61.090273) (xy 130.124308 61.315288) (xy 130.701003 61.43) (xy 131.288997 61.43) (xy 131.865692 61.315288) + (xy 132.408928 61.090273) (xy 132.82331 60.813391) (xy 132.795273 60.905816) (xy 132.781565 61.045) (xy 132.785001 61.079887) + (xy 132.785 75.010123) (xy 132.781565 75.045) (xy 132.795273 75.184184) (xy 132.835872 75.31802) (xy 132.9018 75.441363) + (xy 132.990525 75.549475) (xy 133.025527 75.5782) (xy 133.098637 75.6382) (xy 133.22198 75.704128) (xy 133.355816 75.744727) + (xy 133.495 75.758435) (xy 133.529877 75.755) (xy 147.460123 75.755) (xy 147.495 75.758435) (xy 147.529877 75.755) + (xy 147.634184 75.744727) (xy 147.76802 75.704128) (xy 147.891363 75.6382) (xy 147.999475 75.549475) (xy 148.0882 75.441363) + (xy 148.154128 75.31802) (xy 148.194727 75.184184) (xy 148.208435 75.045) (xy 148.205 75.010123) (xy 148.205 61.837619) + (xy 148.7025 61.837619) (xy 148.7025 99.162381) (xy 151.6225 99.162381) (xy 151.6225 96.635) (xy 151.881565 96.635) + (xy 151.885001 96.669887) (xy 151.885 110.600123) (xy 151.881565 110.635) (xy 151.895273 110.774184) (xy 151.935872 110.90802) + (xy 152.0018 111.031363) (xy 152.090525 111.139475) (xy 152.198637 111.2282) (xy 152.32198 111.294128) (xy 152.455816 111.334727) + (xy 152.595 111.348435) (xy 152.629877 111.345) (xy 166.560123 111.345) (xy 166.595 111.348435) (xy 166.629877 111.345) + (xy 166.734184 111.334727) (xy 166.86802 111.294128) (xy 166.991363 111.2282) (xy 167.099475 111.139475) (xy 167.1882 111.031363) + (xy 167.254128 110.90802) (xy 167.294727 110.774184) (xy 167.308435 110.635) (xy 167.305 110.600123) (xy 167.305 99.145) + (xy 170.881565 99.145) (xy 170.885001 99.179887) (xy 170.885 113.110123) (xy 170.881565 113.145) (xy 170.895273 113.284184) + (xy 170.935872 113.41802) (xy 171.0018 113.541363) (xy 171.090525 113.649475) (xy 171.198637 113.7382) (xy 171.32198 113.804128) + (xy 171.455816 113.844727) (xy 171.595 113.858435) (xy 171.629877 113.855) (xy 185.560123 113.855) (xy 185.595 113.858435) + (xy 185.629877 113.855) (xy 185.734184 113.844727) (xy 185.86802 113.804128) (xy 185.991363 113.7382) (xy 186.099475 113.649475) + (xy 186.1882 113.541363) (xy 186.254128 113.41802) (xy 186.294727 113.284184) (xy 186.308435 113.145) (xy 186.305 113.110123) + (xy 186.305 99.179877) (xy 186.308435 99.145) (xy 186.294727 99.005816) (xy 186.254128 98.87198) (xy 186.1882 98.748637) + (xy 186.099475 98.640525) (xy 185.991363 98.5518) (xy 185.86802 98.485872) (xy 185.734184 98.445273) (xy 185.629877 98.435) + (xy 185.595 98.431565) (xy 185.560123 98.435) (xy 171.629877 98.435) (xy 171.595 98.431565) (xy 171.560123 98.435) + (xy 171.455816 98.445273) (xy 171.32198 98.485872) (xy 171.198637 98.5518) (xy 171.090525 98.640525) (xy 171.0018 98.748637) + (xy 170.935872 98.87198) (xy 170.895273 99.005816) (xy 170.881565 99.145) (xy 167.305 99.145) (xy 167.305 96.669877) + (xy 167.308435 96.635) (xy 167.294727 96.495816) (xy 167.254128 96.36198) (xy 167.1882 96.238637) (xy 167.099475 96.130525) + (xy 166.991363 96.0418) (xy 166.86802 95.975872) (xy 166.734184 95.935273) (xy 166.629877 95.925) (xy 166.595 95.921565) + (xy 166.560123 95.925) (xy 152.629877 95.925) (xy 152.595 95.921565) (xy 152.560123 95.925) (xy 152.455816 95.935273) + (xy 152.32198 95.975872) (xy 152.198637 96.0418) (xy 152.090525 96.130525) (xy 152.0018 96.238637) (xy 151.935872 96.36198) + (xy 151.895273 96.495816) (xy 151.881565 96.635) (xy 151.6225 96.635) (xy 151.6225 77.635) (xy 151.881565 77.635) + (xy 151.885001 77.669887) (xy 151.885 91.600123) (xy 151.881565 91.635) (xy 151.895273 91.774184) (xy 151.935872 91.90802) + (xy 152.0018 92.031363) (xy 152.090525 92.139475) (xy 152.198637 92.2282) (xy 152.32198 92.294128) (xy 152.455816 92.334727) + (xy 152.595 92.348435) (xy 152.629877 92.345) (xy 166.560123 92.345) (xy 166.595 92.348435) (xy 166.629877 92.345) + (xy 166.734184 92.334727) (xy 166.86802 92.294128) (xy 166.991363 92.2282) (xy 167.099475 92.139475) (xy 167.1882 92.031363) + (xy 167.254128 91.90802) (xy 167.294727 91.774184) (xy 167.308435 91.635) (xy 167.305 91.600123) (xy 167.305 80.045) + (xy 170.881565 80.045) (xy 170.885001 80.079887) (xy 170.885 94.010123) (xy 170.881565 94.045) (xy 170.895273 94.184184) + (xy 170.935872 94.31802) (xy 171.0018 94.441363) (xy 171.090525 94.549475) (xy 171.198637 94.6382) (xy 171.32198 94.704128) + (xy 171.455816 94.744727) (xy 171.595 94.758435) (xy 171.629877 94.755) (xy 185.560123 94.755) (xy 185.595 94.758435) + (xy 185.629877 94.755) (xy 185.734184 94.744727) (xy 185.86802 94.704128) (xy 185.991363 94.6382) (xy 186.099475 94.549475) + (xy 186.1882 94.441363) (xy 186.254128 94.31802) (xy 186.294727 94.184184) (xy 186.308435 94.045) (xy 186.305 94.010123) + (xy 186.305 84.945) (xy 189.981565 84.945) (xy 189.985001 84.979887) (xy 189.985 98.910123) (xy 189.981565 98.945) + (xy 189.995273 99.084184) (xy 190.035872 99.21802) (xy 190.1018 99.341363) (xy 190.190525 99.449475) (xy 190.260715 99.507078) + (xy 190.298637 99.5382) (xy 190.42198 99.604128) (xy 190.555816 99.644727) (xy 190.695 99.658435) (xy 190.729877 99.655) + (xy 204.601011 99.655) (xy 204.349727 100.031072) (xy 204.124712 100.574308) (xy 204.01 101.151003) (xy 204.01 101.738997) + (xy 204.124712 102.315692) (xy 204.349727 102.858928) (xy 204.601011 103.235) (xy 190.729877 103.235) (xy 190.695 103.231565) + (xy 190.660123 103.235) (xy 190.555816 103.245273) (xy 190.42198 103.285872) (xy 190.298637 103.3518) (xy 190.190525 103.440525) + (xy 190.1018 103.548637) (xy 190.035872 103.67198) (xy 189.995273 103.805816) (xy 189.981565 103.945) (xy 189.985001 103.979887) + (xy 189.985 117.910123) (xy 189.981565 117.945) (xy 189.995273 118.084184) (xy 190.035872 118.21802) (xy 190.1018 118.341363) + (xy 190.190525 118.449475) (xy 190.274048 118.51802) (xy 190.298637 118.5382) (xy 190.42198 118.604128) (xy 190.555816 118.644727) + (xy 190.695 118.658435) (xy 190.729877 118.655) (xy 204.660123 118.655) (xy 204.695 118.658435) (xy 204.729877 118.655) + (xy 204.834184 118.644727) (xy 204.96802 118.604128) (xy 205.091363 118.5382) (xy 205.199475 118.449475) (xy 205.2882 118.341363) + (xy 205.354128 118.21802) (xy 205.394727 118.084184) (xy 205.408435 117.945) (xy 205.405 117.910123) (xy 205.405 103.979877) + (xy 205.40567 103.973073) (xy 205.581072 104.090273) (xy 206.124308 104.315288) (xy 206.701003 104.43) (xy 207.288997 104.43) + (xy 207.865692 104.315288) (xy 208.408928 104.090273) (xy 208.626343 103.945) (xy 209.031565 103.945) (xy 209.035001 103.979887) + (xy 209.035 117.910123) (xy 209.031565 117.945) (xy 209.045273 118.084184) (xy 209.085872 118.21802) (xy 209.1518 118.341363) + (xy 209.240525 118.449475) (xy 209.324048 118.51802) (xy 209.348637 118.5382) (xy 209.47198 118.604128) (xy 209.605816 118.644727) + (xy 209.745 118.658435) (xy 209.779877 118.655) (xy 223.710123 118.655) (xy 223.745 118.658435) (xy 223.779877 118.655) + (xy 223.884184 118.644727) (xy 224.01802 118.604128) (xy 224.141363 118.5382) (xy 224.249475 118.449475) (xy 224.3382 118.341363) + (xy 224.404128 118.21802) (xy 224.444727 118.084184) (xy 224.458435 117.945) (xy 224.455 117.910123) (xy 224.455 103.979877) + (xy 224.458435 103.945) (xy 224.444727 103.805816) (xy 224.404128 103.67198) (xy 224.3382 103.548637) (xy 224.249475 103.440525) + (xy 224.141363 103.3518) (xy 224.01802 103.285872) (xy 223.884184 103.245273) (xy 223.779877 103.235) (xy 223.745 103.231565) + (xy 223.710123 103.235) (xy 209.779877 103.235) (xy 209.745 103.231565) (xy 209.710123 103.235) (xy 209.605816 103.245273) + (xy 209.47198 103.285872) (xy 209.348637 103.3518) (xy 209.240525 103.440525) (xy 209.1518 103.548637) (xy 209.085872 103.67198) + (xy 209.045273 103.805816) (xy 209.031565 103.945) (xy 208.626343 103.945) (xy 208.897826 103.763601) (xy 209.313601 103.347826) + (xy 209.640273 102.858928) (xy 209.865288 102.315692) (xy 209.98 101.738997) (xy 209.98 101.151003) (xy 209.865288 100.574308) + (xy 209.640273 100.031072) (xy 209.317784 99.548434) (xy 209.42198 99.604128) (xy 209.555816 99.644727) (xy 209.695 99.658435) + (xy 209.729877 99.655) (xy 223.660123 99.655) (xy 223.695 99.658435) (xy 223.729877 99.655) (xy 223.834184 99.644727) + (xy 223.96802 99.604128) (xy 224.091363 99.5382) (xy 224.199475 99.449475) (xy 224.2882 99.341363) (xy 224.354128 99.21802) + (xy 224.394727 99.084184) (xy 224.408435 98.945) (xy 224.405 98.910123) (xy 224.405 84.979877) (xy 224.408435 84.945) + (xy 224.394727 84.805816) (xy 224.354128 84.67198) (xy 224.2882 84.548637) (xy 224.199475 84.440525) (xy 224.091363 84.3518) + (xy 223.96802 84.285872) (xy 223.834184 84.245273) (xy 223.729877 84.235) (xy 223.695 84.231565) (xy 223.660123 84.235) + (xy 209.729877 84.235) (xy 209.695 84.231565) (xy 209.660123 84.235) (xy 209.555816 84.245273) (xy 209.42198 84.285872) + (xy 209.298637 84.3518) (xy 209.190525 84.440525) (xy 209.1018 84.548637) (xy 209.035872 84.67198) (xy 208.995273 84.805816) + (xy 208.981565 84.945) (xy 208.985001 84.979887) (xy 208.985 98.910123) (xy 208.981565 98.945) (xy 208.995273 99.084184) + (xy 209.035872 99.21802) (xy 209.08918 99.317753) (xy 208.897826 99.126399) (xy 208.408928 98.799727) (xy 207.865692 98.574712) + (xy 207.288997 98.46) (xy 206.701003 98.46) (xy 206.124308 98.574712) (xy 205.581072 98.799727) (xy 205.40567 98.916927) + (xy 205.405 98.910123) (xy 205.405 84.979877) (xy 205.408435 84.945) (xy 205.394727 84.805816) (xy 205.354128 84.67198) + (xy 205.2882 84.548637) (xy 205.199475 84.440525) (xy 205.091363 84.3518) (xy 204.96802 84.285872) (xy 204.834184 84.245273) + (xy 204.729877 84.235) (xy 204.695 84.231565) (xy 204.660123 84.235) (xy 190.729877 84.235) (xy 190.695 84.231565) + (xy 190.660123 84.235) (xy 190.555816 84.245273) (xy 190.42198 84.285872) (xy 190.298637 84.3518) (xy 190.190525 84.440525) + (xy 190.1018 84.548637) (xy 190.035872 84.67198) (xy 189.995273 84.805816) (xy 189.981565 84.945) (xy 186.305 84.945) + (xy 186.305 80.079877) (xy 186.308435 80.045) (xy 186.294727 79.905816) (xy 186.254128 79.77198) (xy 186.1882 79.648637) + (xy 186.099475 79.540525) (xy 185.991363 79.4518) (xy 185.86802 79.385872) (xy 185.734184 79.345273) (xy 185.629877 79.335) + (xy 185.595 79.331565) (xy 185.560123 79.335) (xy 171.629877 79.335) (xy 171.595 79.331565) (xy 171.560123 79.335) + (xy 171.455816 79.345273) (xy 171.32198 79.385872) (xy 171.198637 79.4518) (xy 171.090525 79.540525) (xy 171.0018 79.648637) + (xy 170.935872 79.77198) (xy 170.895273 79.905816) (xy 170.881565 80.045) (xy 167.305 80.045) (xy 167.305 77.669877) + (xy 167.308435 77.635) (xy 167.294727 77.495816) (xy 167.254128 77.36198) (xy 167.1882 77.238637) (xy 167.099475 77.130525) + (xy 166.991363 77.0418) (xy 166.86802 76.975872) (xy 166.734184 76.935273) (xy 166.629877 76.925) (xy 166.595 76.921565) + (xy 166.560123 76.925) (xy 152.629877 76.925) (xy 152.595 76.921565) (xy 152.560123 76.925) (xy 152.455816 76.935273) + (xy 152.32198 76.975872) (xy 152.198637 77.0418) (xy 152.090525 77.130525) (xy 152.0018 77.238637) (xy 151.935872 77.36198) + (xy 151.895273 77.495816) (xy 151.881565 77.635) (xy 151.6225 77.635) (xy 151.6225 61.837619) (xy 148.7025 61.837619) + (xy 148.205 61.837619) (xy 148.205 61.079877) (xy 148.208435 61.045) (xy 148.194727 60.905816) (xy 148.154128 60.77198) + (xy 148.0882 60.648637) (xy 147.999475 60.540525) (xy 147.891363 60.4518) (xy 147.76802 60.385872) (xy 147.634184 60.345273) + (xy 147.529877 60.335) (xy 147.495 60.331565) (xy 147.460123 60.335) (xy 133.529877 60.335) (xy 133.495 60.331565) + (xy 133.460123 60.335) (xy 133.355816 60.345273) (xy 133.298884 60.362543) (xy 133.313601 60.347826) (xy 133.640273 59.858928) + (xy 133.865288 59.315692) (xy 133.98 58.738997) (xy 133.98 58.535) (xy 151.881565 58.535) (xy 151.885001 58.569887) + (xy 151.885 72.500123) (xy 151.881565 72.535) (xy 151.895273 72.674184) (xy 151.935872 72.80802) (xy 152.0018 72.931363) + (xy 152.090525 73.039475) (xy 152.198637 73.1282) (xy 152.32198 73.194128) (xy 152.455816 73.234727) (xy 152.595 73.248435) + (xy 152.629877 73.245) (xy 166.560123 73.245) (xy 166.595 73.248435) (xy 166.629877 73.245) (xy 166.734184 73.234727) + (xy 166.86802 73.194128) (xy 166.991363 73.1282) (xy 167.099475 73.039475) (xy 167.1882 72.931363) (xy 167.254128 72.80802) + (xy 167.294727 72.674184) (xy 167.308435 72.535) (xy 167.305 72.500123) (xy 167.305 60.985) (xy 170.881565 60.985) + (xy 170.885001 61.019887) (xy 170.885 74.950123) (xy 170.881565 74.985) (xy 170.895273 75.124184) (xy 170.935872 75.25802) + (xy 171.0018 75.381363) (xy 171.090525 75.489475) (xy 171.198637 75.5782) (xy 171.32198 75.644128) (xy 171.455816 75.684727) + (xy 171.595 75.698435) (xy 171.629877 75.695) (xy 185.560123 75.695) (xy 185.595 75.698435) (xy 185.629877 75.695) + (xy 185.734184 75.684727) (xy 185.86802 75.644128) (xy 185.991363 75.5782) (xy 186.099475 75.489475) (xy 186.1882 75.381363) + (xy 186.254128 75.25802) (xy 186.294727 75.124184) (xy 186.308435 74.985) (xy 186.305 74.950123) (xy 186.305 61.019877) + (xy 186.308435 60.985) (xy 186.294727 60.845816) (xy 186.254128 60.71198) (xy 186.1882 60.588637) (xy 186.099475 60.480525) + (xy 185.991363 60.3918) (xy 185.86802 60.325872) (xy 185.734184 60.285273) (xy 185.629877 60.275) (xy 185.595 60.271565) + (xy 185.560123 60.275) (xy 171.629877 60.275) (xy 171.595 60.271565) (xy 171.560123 60.275) (xy 171.455816 60.285273) + (xy 171.32198 60.325872) (xy 171.198637 60.3918) (xy 171.090525 60.480525) (xy 171.0018 60.588637) (xy 170.935872 60.71198) + (xy 170.895273 60.845816) (xy 170.881565 60.985) (xy 167.305 60.985) (xy 167.305 58.569877) (xy 167.308435 58.535) + (xy 167.294727 58.395816) (xy 167.254128 58.26198) (xy 167.1882 58.138637) (xy 167.099475 58.030525) (xy 166.991363 57.9418) + (xy 166.86802 57.875872) (xy 166.734184 57.835273) (xy 166.629877 57.825) (xy 166.595 57.821565) (xy 166.560123 57.825) + (xy 152.629877 57.825) (xy 152.595 57.821565) (xy 152.560123 57.825) (xy 152.455816 57.835273) (xy 152.32198 57.875872) + (xy 152.198637 57.9418) (xy 152.090525 58.030525) (xy 152.0018 58.138637) (xy 151.935872 58.26198) (xy 151.895273 58.395816) + (xy 151.881565 58.535) (xy 133.98 58.535) (xy 133.98 58.151003) (xy 133.865288 57.574308) (xy 133.640273 57.031072) + (xy 133.383978 56.647501) (xy 133.495 56.658435) (xy 133.529877 56.655) (xy 147.460123 56.655) (xy 147.495 56.658435) + (xy 147.529877 56.655) (xy 147.634184 56.644727) (xy 147.76802 56.604128) (xy 147.891363 56.5382) (xy 147.999475 56.449475) + (xy 148.0882 56.341363) (xy 148.154128 56.21802) (xy 148.194727 56.084184) (xy 148.208435 55.945) (xy 148.205 55.910123) + (xy 148.205 41.979877) (xy 148.208435 41.945) (xy 148.194727 41.805816) (xy 148.154128 41.67198) (xy 148.0882 41.548637) + (xy 147.999475 41.440525) (xy 147.891363 41.3518) (xy 147.76802 41.285872) (xy 147.634184 41.245273) (xy 147.529877 41.235) + (xy 147.495 41.231565) (xy 147.460123 41.235) (xy 133.529877 41.235) (xy 133.495 41.231565) (xy 133.460123 41.235) + (xy 133.355816 41.245273) (xy 133.22198 41.285872) (xy 133.098637 41.3518) (xy 132.990525 41.440525) (xy 132.9018 41.548637) + (xy 132.835872 41.67198) (xy 132.795273 41.805816) (xy 132.781565 41.945) (xy 132.785001 41.979887) (xy 132.785 55.910123) + (xy 132.781565 55.945) (xy 132.792499 56.056022) (xy 132.408928 55.799727) (xy 131.865692 55.574712) (xy 131.288997 55.46) + (xy 130.701003 55.46) (xy 130.124308 55.574712) (xy 129.581072 55.799727) (xy 129.205 56.051011) (xy 129.205 44.479877) + (xy 129.208435 44.445) (xy 129.194727 44.305816) (xy 129.154128 44.17198) (xy 129.0882 44.048637) (xy 128.999475 43.940525) + (xy 128.891363 43.8518) (xy 128.76802 43.785872) (xy 128.634184 43.745273) (xy 128.529877 43.735) (xy 128.495 43.731565) + (xy 128.460123 43.735) (xy 114.529877 43.735) (xy 114.495 43.731565) (xy 114.460123 43.735) (xy 114.355816 43.745273) + (xy 114.22198 43.785872) (xy 114.098637 43.8518) (xy 113.990525 43.940525) (xy 113.9018 44.048637) (xy 113.835872 44.17198) + (xy 113.795273 44.305816) (xy 113.781565 44.445) (xy 112.705 44.445) (xy 112.705 39.445) (xy 151.881565 39.445) + (xy 151.885001 39.479887) (xy 151.885 53.410123) (xy 151.881565 53.445) (xy 151.895273 53.584184) (xy 151.935872 53.71802) + (xy 152.0018 53.841363) (xy 152.090525 53.949475) (xy 152.198637 54.0382) (xy 152.32198 54.104128) (xy 152.455816 54.144727) + (xy 152.595 54.158435) (xy 152.629877 54.155) (xy 166.560123 54.155) (xy 166.595 54.158435) (xy 166.629877 54.155) + (xy 166.734184 54.144727) (xy 166.86802 54.104128) (xy 166.991363 54.0382) (xy 167.099475 53.949475) (xy 167.1882 53.841363) + (xy 167.254128 53.71802) (xy 167.294727 53.584184) (xy 167.308435 53.445) (xy 167.305 53.410123) (xy 167.305 41.985) + (xy 170.881565 41.985) (xy 170.885001 42.019887) (xy 170.885 55.950123) (xy 170.881565 55.985) (xy 170.895273 56.124184) + (xy 170.935872 56.25802) (xy 171.0018 56.381363) (xy 171.090525 56.489475) (xy 171.198637 56.5782) (xy 171.32198 56.644128) + (xy 171.455816 56.684727) (xy 171.595 56.698435) (xy 171.629877 56.695) (xy 185.560123 56.695) (xy 185.595 56.698435) + (xy 185.629877 56.695) (xy 185.734184 56.684727) (xy 185.86802 56.644128) (xy 185.991363 56.5782) (xy 186.099475 56.489475) + (xy 186.1882 56.381363) (xy 186.254128 56.25802) (xy 186.294727 56.124184) (xy 186.308435 55.985) (xy 186.305 55.950123) + (xy 186.305 46.845) (xy 189.981565 46.845) (xy 189.985001 46.879887) (xy 189.985 60.810123) (xy 189.981565 60.845) + (xy 189.995273 60.984184) (xy 190.035872 61.11802) (xy 190.1018 61.241363) (xy 190.190525 61.349475) (xy 190.288645 61.43) + (xy 190.298637 61.4382) (xy 190.42198 61.504128) (xy 190.555816 61.544727) (xy 190.695 61.558435) (xy 190.729877 61.555) + (xy 204.339816 61.555) (xy 204.124712 62.074308) (xy 204.01 62.651003) (xy 204.01 63.238997) (xy 204.124712 63.815692) + (xy 204.349727 64.358928) (xy 204.676399 64.847826) (xy 204.891116 65.062543) (xy 204.834184 65.045273) (xy 204.729877 65.035) + (xy 204.695 65.031565) (xy 204.660123 65.035) (xy 190.729877 65.035) (xy 190.695 65.031565) (xy 190.660123 65.035) + (xy 190.555816 65.045273) (xy 190.42198 65.085872) (xy 190.298637 65.1518) (xy 190.190525 65.240525) (xy 190.1018 65.348637) + (xy 190.035872 65.47198) (xy 189.995273 65.605816) (xy 189.981565 65.745) (xy 189.985001 65.779887) (xy 189.985 79.710123) + (xy 189.981565 79.745) (xy 189.995273 79.884184) (xy 190.035872 80.01802) (xy 190.1018 80.141363) (xy 190.190525 80.249475) + (xy 190.274048 80.31802) (xy 190.298637 80.3382) (xy 190.42198 80.404128) (xy 190.555816 80.444727) (xy 190.695 80.458435) + (xy 190.729877 80.455) (xy 204.660123 80.455) (xy 204.695 80.458435) (xy 204.729877 80.455) (xy 204.834184 80.444727) + (xy 204.96802 80.404128) (xy 205.091363 80.3382) (xy 205.199475 80.249475) (xy 205.2882 80.141363) (xy 205.354128 80.01802) + (xy 205.394727 79.884184) (xy 205.408435 79.745) (xy 205.405 79.710123) (xy 205.405 65.779877) (xy 205.408435 65.745) + (xy 205.394727 65.605816) (xy 205.354128 65.47198) (xy 205.326401 65.420107) (xy 205.581072 65.590273) (xy 206.124308 65.815288) + (xy 206.701003 65.93) (xy 207.288997 65.93) (xy 207.865692 65.815288) (xy 208.035382 65.745) (xy 208.981565 65.745) + (xy 208.985001 65.779887) (xy 208.985 79.710123) (xy 208.981565 79.745) (xy 208.995273 79.884184) (xy 209.035872 80.01802) + (xy 209.1018 80.141363) (xy 209.190525 80.249475) (xy 209.274048 80.31802) (xy 209.298637 80.3382) (xy 209.42198 80.404128) + (xy 209.555816 80.444727) (xy 209.695 80.458435) (xy 209.729877 80.455) (xy 223.660123 80.455) (xy 223.695 80.458435) + (xy 223.729877 80.455) (xy 223.834184 80.444727) (xy 223.96802 80.404128) (xy 224.091363 80.3382) (xy 224.199475 80.249475) + (xy 224.2882 80.141363) (xy 224.354128 80.01802) (xy 224.394727 79.884184) (xy 224.408435 79.745) (xy 224.405 79.710123) + (xy 224.405 65.779877) (xy 224.408435 65.745) (xy 224.394727 65.605816) (xy 224.354128 65.47198) (xy 224.2882 65.348637) + (xy 224.199475 65.240525) (xy 224.091363 65.1518) (xy 223.96802 65.085872) (xy 223.834184 65.045273) (xy 223.729877 65.035) + (xy 223.695 65.031565) (xy 223.660123 65.035) (xy 209.729877 65.035) (xy 209.695 65.031565) (xy 209.660123 65.035) + (xy 209.555816 65.045273) (xy 209.42198 65.085872) (xy 209.298637 65.1518) (xy 209.190525 65.240525) (xy 209.1018 65.348637) + (xy 209.035872 65.47198) (xy 208.995273 65.605816) (xy 208.981565 65.745) (xy 208.035382 65.745) (xy 208.408928 65.590273) + (xy 208.897826 65.263601) (xy 209.313601 64.847826) (xy 209.640273 64.358928) (xy 209.865288 63.815692) (xy 209.98 63.238997) + (xy 209.98 62.651003) (xy 209.865288 62.074308) (xy 209.649762 61.55398) (xy 209.695 61.558435) (xy 209.729877 61.555) + (xy 223.660123 61.555) (xy 223.695 61.558435) (xy 223.729877 61.555) (xy 223.834184 61.544727) (xy 223.96802 61.504128) + (xy 224.091363 61.4382) (xy 224.199475 61.349475) (xy 224.2882 61.241363) (xy 224.354128 61.11802) (xy 224.394727 60.984184) + (xy 224.408435 60.845) (xy 224.405 60.810123) (xy 224.405 46.879877) (xy 224.408435 46.845) (xy 224.394727 46.705816) + (xy 224.354128 46.57198) (xy 224.2882 46.448637) (xy 224.199475 46.340525) (xy 224.091363 46.2518) (xy 223.96802 46.185872) + (xy 223.834184 46.145273) (xy 223.729877 46.135) (xy 223.695 46.131565) (xy 223.660123 46.135) (xy 209.729877 46.135) + (xy 209.695 46.131565) (xy 209.660123 46.135) (xy 209.555816 46.145273) (xy 209.42198 46.185872) (xy 209.298637 46.2518) + (xy 209.190525 46.340525) (xy 209.1018 46.448637) (xy 209.035872 46.57198) (xy 208.995273 46.705816) (xy 208.981565 46.845) + (xy 208.985001 46.879887) (xy 208.985 60.713573) (xy 208.897826 60.626399) (xy 208.408928 60.299727) (xy 207.865692 60.074712) + (xy 207.288997 59.96) (xy 206.701003 59.96) (xy 206.124308 60.074712) (xy 205.581072 60.299727) (xy 205.405 60.417375) + (xy 205.405 46.879877) (xy 205.408435 46.845) (xy 205.394727 46.705816) (xy 205.354128 46.57198) (xy 205.2882 46.448637) + (xy 205.199475 46.340525) (xy 205.091363 46.2518) (xy 204.96802 46.185872) (xy 204.834184 46.145273) (xy 204.729877 46.135) + (xy 204.695 46.131565) (xy 204.660123 46.135) (xy 190.729877 46.135) (xy 190.695 46.131565) (xy 190.660123 46.135) + (xy 190.555816 46.145273) (xy 190.42198 46.185872) (xy 190.298637 46.2518) (xy 190.190525 46.340525) (xy 190.1018 46.448637) + (xy 190.035872 46.57198) (xy 189.995273 46.705816) (xy 189.981565 46.845) (xy 186.305 46.845) (xy 186.305 42.019877) + (xy 186.308435 41.985) (xy 186.294727 41.845816) (xy 186.254128 41.71198) (xy 186.1882 41.588637) (xy 186.099475 41.480525) + (xy 185.991363 41.3918) (xy 185.86802 41.325872) (xy 185.734184 41.285273) (xy 185.629877 41.275) (xy 185.595 41.271565) + (xy 185.560123 41.275) (xy 171.629877 41.275) (xy 171.595 41.271565) (xy 171.560123 41.275) (xy 171.455816 41.285273) + (xy 171.32198 41.325872) (xy 171.198637 41.3918) (xy 171.090525 41.480525) (xy 171.0018 41.588637) (xy 170.935872 41.71198) + (xy 170.895273 41.845816) (xy 170.881565 41.985) (xy 167.305 41.985) (xy 167.305 39.479877) (xy 167.308435 39.445) + (xy 167.294727 39.305816) (xy 167.254128 39.17198) (xy 167.1882 39.048637) (xy 167.099475 38.940525) (xy 166.991363 38.8518) + (xy 166.86802 38.785872) (xy 166.734184 38.745273) (xy 166.629877 38.735) (xy 166.595 38.731565) (xy 166.560123 38.735) + (xy 152.629877 38.735) (xy 152.595 38.731565) (xy 152.560123 38.735) (xy 152.455816 38.745273) (xy 152.32198 38.785872) + (xy 152.198637 38.8518) (xy 152.090525 38.940525) (xy 152.0018 39.048637) (xy 151.935872 39.17198) (xy 151.895273 39.305816) + (xy 151.881565 39.445) (xy 112.705 39.445) (xy 112.705 39.145821) (xy 112.746463 39.002775) (xy 112.846756 38.852335) + (xy 112.915575 38.783516) (xy 112.967387 38.75761) (xy 113.193645 38.68219) (xy 113.601036 38.580342) (xy 113.61046 38.576975) + (xy 150.008615 37.13) (xy 171.891299 37.13) + ) + ) + ) + (zone (net 0) (net_name "") (layer B.Cu) (tstamp 5F80D23C) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508)) + (polygon + (pts + (xy 81.845 128.695) (xy 93.595 149.295) (xy 139.095 136.295) (xy 188.445 136.745) (xy 227.595 123.145) + (xy 226.795 44.745) (xy 172.495 35.645) (xy 88.595 38.345) (xy 88.945 116.095) + ) + ) + (filled_polygon + (pts + (xy 225.331807 45.561746) (xy 225.442617 45.590115) (xy 225.516481 45.623972) (xy 225.582585 45.669767) (xy 225.639771 45.726261) + (xy 225.686436 45.791768) (xy 225.721105 45.864343) (xy 225.742732 45.942657) (xy 225.753192 46.058012) (xy 225.780002 120.446646) + (xy 212.970358 125.338376) (xy 212.180322 123.280262) (xy 190.802665 131.486376) (xy 191.578491 133.507472) (xy 188.29858 134.76) + (xy 139.153838 134.76) (xy 139.091265 134.759123) (xy 139.053284 134.766126) (xy 139.014845 134.769912) (xy 138.954927 134.788088) + (xy 94.859605 147.492335) (xy 94.515432 147.429758) (xy 94.238912 147.337584) (xy 94.07999 147.201366) (xy 85.462387 132.236162) + (xy 87.430915 132.236162) (xy 87.435491 132.375943) (xy 87.467249 132.512148) (xy 87.52497 132.639539) (xy 87.545383 132.668025) + (xy 94.510511 144.731983) (xy 94.52497 144.763895) (xy 94.545377 144.792373) (xy 94.545382 144.792382) (xy 94.606432 144.877578) + (xy 94.676889 144.943567) (xy 94.708511 144.973184) (xy 94.753423 145.001112) (xy 94.827277 145.047038) (xy 94.958171 145.096303) + (xy 95.096161 145.119085) (xy 95.096162 145.119085) (xy 95.235943 145.114509) (xy 95.372148 145.082751) (xy 95.467617 145.039494) + (xy 95.467618 145.039494) (xy 95.499539 145.02503) (xy 95.528025 145.004617) (xy 107.591983 138.039489) (xy 107.623895 138.02503) + (xy 107.652373 138.004623) (xy 107.652382 138.004618) (xy 107.737578 137.943568) (xy 107.833183 137.84149) (xy 107.907038 137.722723) + (xy 107.956303 137.591829) (xy 107.979085 137.453839) (xy 107.974509 137.314057) (xy 107.942751 137.177852) (xy 107.942751 137.177851) + (xy 107.899494 137.082382) (xy 107.899491 137.082377) (xy 107.88503 137.050461) (xy 107.86462 137.021979) (xy 100.899493 124.958025) + (xy 100.892194 124.941914) (xy 109.309879 124.941914) (xy 109.332661 125.079903) (xy 109.345005 125.112701) (xy 112.950421 138.568296) + (xy 112.956128 138.602864) (xy 112.968469 138.635654) (xy 112.968472 138.635664) (xy 113.005392 138.733758) (xy 113.079247 138.852526) + (xy 113.174852 138.954603) (xy 113.288535 139.036067) (xy 113.415927 139.093787) (xy 113.55213 139.125545) (xy 113.691914 139.130122) + (xy 113.829903 139.107339) (xy 113.862704 139.094994) (xy 127.318294 135.48958) (xy 127.352864 135.483872) (xy 127.385657 135.47153) + (xy 127.385664 135.471528) (xy 127.483758 135.434608) (xy 127.602526 135.360753) (xy 127.704603 135.265148) (xy 127.786067 135.151465) + (xy 127.843787 135.024073) (xy 127.875545 134.88787) (xy 127.880122 134.748086) (xy 127.857339 134.610097) (xy 127.844995 134.577299) + (xy 124.239581 121.121716) (xy 124.233872 121.087136) (xy 124.184608 120.956242) (xy 124.110753 120.837474) (xy 124.015148 120.735398) + (xy 123.901465 120.653933) (xy 123.774073 120.596213) (xy 123.637869 120.564455) (xy 123.498086 120.559879) (xy 123.394674 120.576952) + (xy 123.394671 120.576953) (xy 123.360097 120.582661) (xy 123.327301 120.595005) (xy 109.871713 124.200419) (xy 109.837136 124.206128) + (xy 109.804336 124.218473) (xy 109.706242 124.255393) (xy 109.587475 124.329248) (xy 109.485398 124.424853) (xy 109.403933 124.538536) + (xy 109.346213 124.665928) (xy 109.314455 124.802131) (xy 109.309879 124.941914) (xy 100.892194 124.941914) (xy 100.88503 124.926105) + (xy 100.803567 124.812422) (xy 100.701489 124.716816) (xy 100.582722 124.642962) (xy 100.451828 124.593697) (xy 100.313838 124.570915) + (xy 100.174056 124.575491) (xy 100.037851 124.607249) (xy 99.942382 124.650506) (xy 99.942377 124.650509) (xy 99.910461 124.66497) + (xy 99.881979 124.68538) (xy 87.818025 131.650507) (xy 87.786105 131.66497) (xy 87.75762 131.685382) (xy 87.757618 131.685383) + (xy 87.672422 131.746433) (xy 87.576816 131.848511) (xy 87.502962 131.967278) (xy 87.453697 132.098172) (xy 87.430915 132.236162) + (xy 85.462387 132.236162) (xy 83.928274 129.572044) (xy 83.821687 129.216756) (xy 83.78 128.716515) (xy 83.78 128.412828) + (xy 83.846575 128.079954) (xy 88.124521 120.151003) (xy 101.01 120.151003) (xy 101.01 120.738997) (xy 101.124712 121.315692) + (xy 101.349727 121.858928) (xy 101.676399 122.347826) (xy 102.092174 122.763601) (xy 102.581072 123.090273) (xy 103.124308 123.315288) + (xy 103.701003 123.43) (xy 104.288997 123.43) (xy 104.865692 123.315288) (xy 105.408928 123.090273) (xy 105.897826 122.763601) + (xy 106.313601 122.347826) (xy 106.640273 121.858928) (xy 106.865288 121.315692) (xy 106.98 120.738997) (xy 106.98 120.151003) + (xy 106.865288 119.574308) (xy 106.640273 119.031072) (xy 106.313601 118.542174) (xy 105.916427 118.145) (xy 132.781565 118.145) + (xy 132.785001 118.179887) (xy 132.785 132.110123) (xy 132.781565 132.145) (xy 132.795273 132.284184) (xy 132.835872 132.41802) + (xy 132.9018 132.541363) (xy 132.990525 132.649475) (xy 133.098637 132.7382) (xy 133.22198 132.804128) (xy 133.355816 132.844727) + (xy 133.495 132.858435) (xy 133.529877 132.855) (xy 147.460123 132.855) (xy 147.495 132.858435) (xy 147.529877 132.855) + (xy 147.592545 132.848828) (xy 147.634184 132.844727) (xy 147.76802 132.804128) (xy 147.891363 132.7382) (xy 147.999475 132.649475) + (xy 148.0882 132.541363) (xy 148.154128 132.41802) (xy 148.194727 132.284184) (xy 148.205 132.179877) (xy 148.205 132.179876) + (xy 148.208435 132.145) (xy 148.205 132.110123) (xy 148.205 118.179877) (xy 148.208435 118.145) (xy 148.194727 118.005816) + (xy 148.154128 117.87198) (xy 148.0882 117.748637) (xy 147.999475 117.640525) (xy 147.891363 117.5518) (xy 147.76802 117.485872) + (xy 147.634184 117.445273) (xy 147.529877 117.435) (xy 147.495 117.431565) (xy 147.460123 117.435) (xy 133.529877 117.435) + (xy 133.495 117.431565) (xy 133.460123 117.435) (xy 133.355816 117.445273) (xy 133.22198 117.485872) (xy 133.098637 117.5518) + (xy 132.990525 117.640525) (xy 132.9018 117.748637) (xy 132.835872 117.87198) (xy 132.795273 118.005816) (xy 132.781565 118.145) + (xy 105.916427 118.145) (xy 105.897826 118.126399) (xy 105.408928 117.799727) (xy 104.865692 117.574712) (xy 104.288997 117.46) + (xy 103.701003 117.46) (xy 103.124308 117.574712) (xy 102.581072 117.799727) (xy 102.092174 118.126399) (xy 101.676399 118.542174) + (xy 101.349727 119.031072) (xy 101.124712 119.574308) (xy 101.01 120.151003) (xy 88.124521 120.151003) (xy 89.578074 117.456918) + (xy 89.59298 117.435873) (xy 89.610021 117.397706) (xy 89.613829 117.390648) (xy 89.62376 117.366935) (xy 89.634207 117.343536) + (xy 89.636735 117.335952) (xy 89.652891 117.297374) (xy 89.658024 117.272087) (xy 89.83531 116.74023) (xy 89.850164 116.706034) + (xy 89.863713 116.643522) (xy 89.877908 116.58109) (xy 89.878923 116.543817) (xy 89.943563 115.985526) (xy 89.945109 115.98046) + (xy 89.95131 115.918616) (xy 89.954581 115.89036) (xy 89.954671 115.885087) (xy 89.955197 115.879842) (xy 89.955247 115.851414) + (xy 89.956309 115.789252) (xy 89.955364 115.784038) (xy 89.983002 99.945) (xy 92.481565 99.945) (xy 92.485 99.979877) + (xy 92.485001 111.910113) (xy 92.481565 111.945) (xy 92.495273 112.084184) (xy 92.535872 112.21802) (xy 92.6018 112.341363) + (xy 92.690525 112.449475) (xy 92.798637 112.5382) (xy 92.92198 112.604128) (xy 93.055816 112.644727) (xy 93.160123 112.655) + (xy 93.195 112.658435) (xy 93.229877 112.655) (xy 108.760123 112.655) (xy 108.795 112.658435) (xy 108.829877 112.655) + (xy 108.934184 112.644727) (xy 109.06802 112.604128) (xy 109.191363 112.5382) (xy 109.299475 112.449475) (xy 109.3882 112.341363) + (xy 109.454128 112.21802) (xy 109.494727 112.084184) (xy 109.508435 111.945) (xy 109.505 111.910123) (xy 109.505 99.979877) + (xy 109.508435 99.945) (xy 109.494727 99.805816) (xy 109.454128 99.67198) (xy 109.3882 99.548637) (xy 109.299475 99.440525) + (xy 109.191363 99.3518) (xy 109.06802 99.285872) (xy 108.934184 99.245273) (xy 108.829877 99.235) (xy 108.795 99.231565) + (xy 108.760123 99.235) (xy 93.229877 99.235) (xy 93.195 99.231565) (xy 93.160123 99.235) (xy 93.055816 99.245273) + (xy 92.92198 99.285872) (xy 92.798637 99.3518) (xy 92.690525 99.440525) (xy 92.6018 99.548637) (xy 92.535872 99.67198) + (xy 92.495273 99.805816) (xy 92.481565 99.945) (xy 89.983002 99.945) (xy 89.984691 98.977395) (xy 90.005575 98.879143) + (xy 90.006611 98.869285) (xy 90.018863 98.744335) (xy 90.03503 98.690786) (xy 90.061288 98.641403) (xy 90.096641 98.598055) + (xy 90.13974 98.5624) (xy 90.188937 98.535799) (xy 90.242375 98.519258) (xy 90.330455 98.51) (xy 111.029877 98.51) + (xy 111.060222 98.507011) (xy 111.066332 98.507054) (xy 111.076198 98.506086) (xy 111.270295 98.485685) (xy 111.33331 98.47275) + (xy 111.39654 98.460688) (xy 111.40603 98.457823) (xy 111.592468 98.400111) (xy 111.651797 98.375171) (xy 111.711455 98.351068) + (xy 111.720208 98.346414) (xy 111.891885 98.253589) (xy 111.945198 98.217629) (xy 111.999083 98.182367) (xy 112.006765 98.176102) + (xy 112.157143 98.051698) (xy 112.20248 98.006043) (xy 112.248463 97.961013) (xy 112.254782 97.953375) (xy 112.378132 97.802133) + (xy 112.413757 97.748513) (xy 112.450099 97.695436) (xy 112.454814 97.686716) (xy 112.546439 97.514394) (xy 112.570951 97.454924) + (xy 112.596312 97.395752) (xy 112.599243 97.386282) (xy 112.655652 97.199446) (xy 112.668152 97.136316) (xy 112.68153 97.073377) + (xy 112.682566 97.063519) (xy 112.701611 96.869285) (xy 112.705 96.834877) (xy 112.705 82.545) (xy 113.781565 82.545) + (xy 113.785001 82.579887) (xy 113.785 96.510123) (xy 113.781565 96.545) (xy 113.795273 96.684184) (xy 113.835872 96.81802) + (xy 113.9018 96.941363) (xy 113.990525 97.049475) (xy 114.069533 97.114315) (xy 114.098637 97.1382) (xy 114.22198 97.204128) + (xy 114.355816 97.244727) (xy 114.495 97.258435) (xy 114.529877 97.255) (xy 128.460123 97.255) (xy 128.495 97.258435) + (xy 128.529877 97.255) (xy 128.534497 97.254545) (xy 128.349727 97.531072) (xy 128.124712 98.074308) (xy 128.01 98.651003) + (xy 128.01 99.238997) (xy 128.124712 99.815692) (xy 128.349727 100.358928) (xy 128.676399 100.847826) (xy 128.691116 100.862543) + (xy 128.634184 100.845273) (xy 128.529877 100.835) (xy 128.495 100.831565) (xy 128.460123 100.835) (xy 114.529877 100.835) + (xy 114.495 100.831565) (xy 114.460123 100.835) (xy 114.355816 100.845273) (xy 114.22198 100.885872) (xy 114.098637 100.9518) + (xy 113.990525 101.040525) (xy 113.9018 101.148637) (xy 113.835872 101.27198) (xy 113.795273 101.405816) (xy 113.781565 101.545) + (xy 113.785001 101.579887) (xy 113.785 115.510123) (xy 113.781565 115.545) (xy 113.795273 115.684184) (xy 113.835872 115.81802) + (xy 113.9018 115.941363) (xy 113.990525 116.049475) (xy 114.090306 116.131363) (xy 114.098637 116.1382) (xy 114.22198 116.204128) + (xy 114.355816 116.244727) (xy 114.495 116.258435) (xy 114.529877 116.255) (xy 128.460123 116.255) (xy 128.495 116.258435) + (xy 128.529877 116.255) (xy 128.634184 116.244727) (xy 128.76802 116.204128) (xy 128.891363 116.1382) (xy 128.999475 116.049475) + (xy 129.0882 115.941363) (xy 129.154128 115.81802) (xy 129.179312 115.735) (xy 151.881565 115.735) (xy 151.885001 115.769887) + (xy 151.885 129.700123) (xy 151.881565 129.735) (xy 151.895273 129.874184) (xy 151.935872 130.00802) (xy 152.0018 130.131363) + (xy 152.090525 130.239475) (xy 152.198637 130.3282) (xy 152.32198 130.394128) (xy 152.455816 130.434727) (xy 152.595 130.448435) + (xy 152.629877 130.445) (xy 166.560123 130.445) (xy 166.595 130.448435) (xy 166.629877 130.445) (xy 166.734184 130.434727) + (xy 166.86802 130.394128) (xy 166.991363 130.3282) (xy 167.099475 130.239475) (xy 167.1882 130.131363) (xy 167.254128 130.00802) + (xy 167.294727 129.874184) (xy 167.308435 129.735) (xy 167.305 129.700123) (xy 167.305 118.245) (xy 170.881565 118.245) + (xy 170.885001 118.279887) (xy 170.885 132.210123) (xy 170.881565 132.245) (xy 170.895273 132.384184) (xy 170.935872 132.51802) + (xy 171.0018 132.641363) (xy 171.090525 132.749475) (xy 171.198637 132.8382) (xy 171.32198 132.904128) (xy 171.455816 132.944727) + (xy 171.595 132.958435) (xy 171.629877 132.955) (xy 185.560123 132.955) (xy 185.595 132.958435) (xy 185.629877 132.955) + (xy 185.734184 132.944727) (xy 185.86802 132.904128) (xy 185.991363 132.8382) (xy 186.099475 132.749475) (xy 186.1882 132.641363) + (xy 186.254128 132.51802) (xy 186.294727 132.384184) (xy 186.308435 132.245) (xy 186.305 132.210123) (xy 186.305 118.279877) + (xy 186.308435 118.245) (xy 186.294727 118.105816) (xy 186.254128 117.97198) (xy 186.1882 117.848637) (xy 186.099475 117.740525) + (xy 185.991363 117.6518) (xy 185.86802 117.585872) (xy 185.734184 117.545273) (xy 185.629877 117.535) (xy 185.595 117.531565) + (xy 185.560123 117.535) (xy 171.629877 117.535) (xy 171.595 117.531565) (xy 171.560123 117.535) (xy 171.455816 117.545273) + (xy 171.32198 117.585872) (xy 171.198637 117.6518) (xy 171.090525 117.740525) (xy 171.0018 117.848637) (xy 170.935872 117.97198) + (xy 170.895273 118.105816) (xy 170.881565 118.245) (xy 167.305 118.245) (xy 167.305 115.769877) (xy 167.308435 115.735) + (xy 167.294727 115.595816) (xy 167.254128 115.46198) (xy 167.1882 115.338637) (xy 167.099475 115.230525) (xy 166.991363 115.1418) + (xy 166.86802 115.075872) (xy 166.734184 115.035273) (xy 166.629877 115.025) (xy 166.595 115.021565) (xy 166.560123 115.025) + (xy 152.629877 115.025) (xy 152.595 115.021565) (xy 152.560123 115.025) (xy 152.455816 115.035273) (xy 152.32198 115.075872) + (xy 152.198637 115.1418) (xy 152.090525 115.230525) (xy 152.0018 115.338637) (xy 151.935872 115.46198) (xy 151.895273 115.595816) + (xy 151.881565 115.735) (xy 129.179312 115.735) (xy 129.194727 115.684184) (xy 129.208435 115.545) (xy 129.205 115.510123) + (xy 129.205 101.579877) (xy 129.208435 101.545) (xy 129.194727 101.405816) (xy 129.16669 101.313391) (xy 129.581072 101.590273) + (xy 130.124308 101.815288) (xy 130.701003 101.93) (xy 131.288997 101.93) (xy 131.865692 101.815288) (xy 132.408928 101.590273) + (xy 132.785001 101.338989) (xy 132.785 113.110123) (xy 132.781565 113.145) (xy 132.795273 113.284184) (xy 132.835872 113.41802) + (xy 132.9018 113.541363) (xy 132.990525 113.649475) (xy 133.098637 113.7382) (xy 133.22198 113.804128) (xy 133.355816 113.844727) + (xy 133.495 113.858435) (xy 133.529877 113.855) (xy 147.460123 113.855) (xy 147.495 113.858435) (xy 147.529877 113.855) + (xy 147.634184 113.844727) (xy 147.76802 113.804128) (xy 147.891363 113.7382) (xy 147.999475 113.649475) (xy 148.0882 113.541363) + (xy 148.154128 113.41802) (xy 148.194727 113.284184) (xy 148.208435 113.145) (xy 148.205 113.110123) (xy 148.205 99.179877) + (xy 148.208435 99.145) (xy 148.194727 99.005816) (xy 148.154128 98.87198) (xy 148.0882 98.748637) (xy 147.999475 98.640525) + (xy 147.891363 98.5518) (xy 147.76802 98.485872) (xy 147.634184 98.445273) (xy 147.529877 98.435) (xy 147.495 98.431565) + (xy 147.460123 98.435) (xy 133.937034 98.435) (xy 133.865288 98.074308) (xy 133.640273 97.531072) (xy 133.313601 97.042174) + (xy 132.897826 96.626399) (xy 132.408928 96.299727) (xy 131.865692 96.074712) (xy 131.288997 95.96) (xy 130.701003 95.96) + (xy 130.124308 96.074712) (xy 129.581072 96.299727) (xy 129.208043 96.548977) (xy 129.208435 96.545) (xy 129.205 96.510123) + (xy 129.205 82.579877) (xy 129.208435 82.545) (xy 129.194727 82.405816) (xy 129.154128 82.27198) (xy 129.0882 82.148637) + (xy 128.999475 82.040525) (xy 128.891363 81.9518) (xy 128.76802 81.885872) (xy 128.634184 81.845273) (xy 128.529877 81.835) + (xy 128.495 81.831565) (xy 128.460123 81.835) (xy 114.529877 81.835) (xy 114.495 81.831565) (xy 114.460123 81.835) + (xy 114.355816 81.845273) (xy 114.22198 81.885872) (xy 114.098637 81.9518) (xy 113.990525 82.040525) (xy 113.9018 82.148637) + (xy 113.835872 82.27198) (xy 113.795273 82.405816) (xy 113.781565 82.545) (xy 112.705 82.545) (xy 112.705 63.545) + (xy 113.781565 63.545) (xy 113.785001 63.579887) (xy 113.785 77.510123) (xy 113.781565 77.545) (xy 113.795273 77.684184) + (xy 113.835872 77.81802) (xy 113.9018 77.941363) (xy 113.990525 78.049475) (xy 114.098637 78.1382) (xy 114.22198 78.204128) + (xy 114.355816 78.244727) (xy 114.495 78.258435) (xy 114.529877 78.255) (xy 128.460123 78.255) (xy 128.495 78.258435) + (xy 128.529877 78.255) (xy 128.634184 78.244727) (xy 128.76802 78.204128) (xy 128.891363 78.1382) (xy 128.999475 78.049475) + (xy 129.0882 77.941363) (xy 129.154128 77.81802) (xy 129.194727 77.684184) (xy 129.208435 77.545) (xy 129.205 77.510123) + (xy 129.205 63.579877) (xy 129.208435 63.545) (xy 129.194727 63.405816) (xy 129.154128 63.27198) (xy 129.0882 63.148637) + (xy 129.039102 63.08881) (xy 129.43 63.08881) (xy 129.43 95.511191) (xy 132.4 95.511191) (xy 132.4 80.045) + (xy 132.781565 80.045) (xy 132.785001 80.079887) (xy 132.785 94.010123) (xy 132.781565 94.045) (xy 132.795273 94.184184) + (xy 132.835872 94.31802) (xy 132.9018 94.441363) (xy 132.990525 94.549475) (xy 133.098637 94.6382) (xy 133.22198 94.704128) + (xy 133.355816 94.744727) (xy 133.495 94.758435) (xy 133.529877 94.755) (xy 147.460123 94.755) (xy 147.495 94.758435) + (xy 147.529877 94.755) (xy 147.634184 94.744727) (xy 147.76802 94.704128) (xy 147.891363 94.6382) (xy 147.999475 94.549475) + (xy 148.0882 94.441363) (xy 148.154128 94.31802) (xy 148.194727 94.184184) (xy 148.208435 94.045) (xy 148.205 94.010123) + (xy 148.205 80.079877) (xy 148.208435 80.045) (xy 148.194727 79.905816) (xy 148.154128 79.77198) (xy 148.0882 79.648637) + (xy 147.999475 79.540525) (xy 147.891363 79.4518) (xy 147.76802 79.385872) (xy 147.634184 79.345273) (xy 147.529877 79.335) + (xy 147.495 79.331565) (xy 147.460123 79.335) (xy 133.529877 79.335) (xy 133.495 79.331565) (xy 133.460123 79.335) + (xy 133.355816 79.345273) (xy 133.22198 79.385872) (xy 133.098637 79.4518) (xy 132.990525 79.540525) (xy 132.9018 79.648637) + (xy 132.835872 79.77198) (xy 132.795273 79.905816) (xy 132.781565 80.045) (xy 132.4 80.045) (xy 132.4 63.08881) + (xy 129.43 63.08881) (xy 129.039102 63.08881) (xy 128.999475 63.040525) (xy 128.891363 62.9518) (xy 128.76802 62.885872) + (xy 128.634184 62.845273) (xy 128.529877 62.835) (xy 128.495 62.831565) (xy 128.460123 62.835) (xy 114.529877 62.835) + (xy 114.495 62.831565) (xy 114.460123 62.835) (xy 114.355816 62.845273) (xy 114.22198 62.885872) (xy 114.098637 62.9518) + (xy 113.990525 63.040525) (xy 113.9018 63.148637) (xy 113.835872 63.27198) (xy 113.795273 63.405816) (xy 113.781565 63.545) + (xy 112.705 63.545) (xy 112.705 44.445) (xy 113.781565 44.445) (xy 113.785001 44.479887) (xy 113.785 58.410123) + (xy 113.781565 58.445) (xy 113.795273 58.584184) (xy 113.835872 58.71802) (xy 113.9018 58.841363) (xy 113.990525 58.949475) + (xy 114.098637 59.0382) (xy 114.22198 59.104128) (xy 114.355816 59.144727) (xy 114.495 59.158435) (xy 114.529877 59.155) + (xy 128.092748 59.155) (xy 128.124712 59.315692) (xy 128.349727 59.858928) (xy 128.676399 60.347826) (xy 129.092174 60.763601) + (xy 129.581072 61.090273) (xy 130.124308 61.315288) (xy 130.701003 61.43) (xy 131.288997 61.43) (xy 131.865692 61.315288) + (xy 132.408928 61.090273) (xy 132.82331 60.813391) (xy 132.795273 60.905816) (xy 132.781565 61.045) (xy 132.785001 61.079887) + (xy 132.785 75.010123) (xy 132.781565 75.045) (xy 132.795273 75.184184) (xy 132.835872 75.31802) (xy 132.9018 75.441363) + (xy 132.990525 75.549475) (xy 133.025527 75.5782) (xy 133.098637 75.6382) (xy 133.22198 75.704128) (xy 133.355816 75.744727) + (xy 133.495 75.758435) (xy 133.529877 75.755) (xy 147.460123 75.755) (xy 147.495 75.758435) (xy 147.529877 75.755) + (xy 147.634184 75.744727) (xy 147.76802 75.704128) (xy 147.891363 75.6382) (xy 147.999475 75.549475) (xy 148.0882 75.441363) + (xy 148.154128 75.31802) (xy 148.194727 75.184184) (xy 148.208435 75.045) (xy 148.205 75.010123) (xy 148.205 61.837619) + (xy 148.8675 61.837619) (xy 148.8675 99.162381) (xy 151.7875 99.162381) (xy 151.7875 96.635) (xy 151.881565 96.635) + (xy 151.885001 96.669887) (xy 151.885 110.600123) (xy 151.881565 110.635) (xy 151.895273 110.774184) (xy 151.935872 110.90802) + (xy 152.0018 111.031363) (xy 152.090525 111.139475) (xy 152.198637 111.2282) (xy 152.32198 111.294128) (xy 152.455816 111.334727) + (xy 152.595 111.348435) (xy 152.629877 111.345) (xy 166.560123 111.345) (xy 166.595 111.348435) (xy 166.629877 111.345) + (xy 166.734184 111.334727) (xy 166.86802 111.294128) (xy 166.991363 111.2282) (xy 167.099475 111.139475) (xy 167.1882 111.031363) + (xy 167.254128 110.90802) (xy 167.294727 110.774184) (xy 167.308435 110.635) (xy 167.305 110.600123) (xy 167.305 99.145) + (xy 170.881565 99.145) (xy 170.885001 99.179887) (xy 170.885 113.110123) (xy 170.881565 113.145) (xy 170.895273 113.284184) + (xy 170.935872 113.41802) (xy 171.0018 113.541363) (xy 171.090525 113.649475) (xy 171.198637 113.7382) (xy 171.32198 113.804128) + (xy 171.455816 113.844727) (xy 171.595 113.858435) (xy 171.629877 113.855) (xy 185.560123 113.855) (xy 185.595 113.858435) + (xy 185.629877 113.855) (xy 185.734184 113.844727) (xy 185.86802 113.804128) (xy 185.991363 113.7382) (xy 186.099475 113.649475) + (xy 186.1882 113.541363) (xy 186.254128 113.41802) (xy 186.294727 113.284184) (xy 186.308435 113.145) (xy 186.305 113.110123) + (xy 186.305 99.179877) (xy 186.308435 99.145) (xy 186.294727 99.005816) (xy 186.254128 98.87198) (xy 186.1882 98.748637) + (xy 186.099475 98.640525) (xy 185.991363 98.5518) (xy 185.86802 98.485872) (xy 185.734184 98.445273) (xy 185.629877 98.435) + (xy 185.595 98.431565) (xy 185.560123 98.435) (xy 171.629877 98.435) (xy 171.595 98.431565) (xy 171.560123 98.435) + (xy 171.455816 98.445273) (xy 171.32198 98.485872) (xy 171.198637 98.5518) (xy 171.090525 98.640525) (xy 171.0018 98.748637) + (xy 170.935872 98.87198) (xy 170.895273 99.005816) (xy 170.881565 99.145) (xy 167.305 99.145) (xy 167.305 96.669877) + (xy 167.308435 96.635) (xy 167.294727 96.495816) (xy 167.254128 96.36198) (xy 167.1882 96.238637) (xy 167.099475 96.130525) + (xy 166.991363 96.0418) (xy 166.86802 95.975872) (xy 166.734184 95.935273) (xy 166.629877 95.925) (xy 166.595 95.921565) + (xy 166.560123 95.925) (xy 152.629877 95.925) (xy 152.595 95.921565) (xy 152.560123 95.925) (xy 152.455816 95.935273) + (xy 152.32198 95.975872) (xy 152.198637 96.0418) (xy 152.090525 96.130525) (xy 152.0018 96.238637) (xy 151.935872 96.36198) + (xy 151.895273 96.495816) (xy 151.881565 96.635) (xy 151.7875 96.635) (xy 151.7875 77.635) (xy 151.881565 77.635) + (xy 151.885001 77.669887) (xy 151.885 91.600123) (xy 151.881565 91.635) (xy 151.895273 91.774184) (xy 151.935872 91.90802) + (xy 152.0018 92.031363) (xy 152.090525 92.139475) (xy 152.198637 92.2282) (xy 152.32198 92.294128) (xy 152.455816 92.334727) + (xy 152.595 92.348435) (xy 152.629877 92.345) (xy 166.560123 92.345) (xy 166.595 92.348435) (xy 166.629877 92.345) + (xy 166.734184 92.334727) (xy 166.86802 92.294128) (xy 166.991363 92.2282) (xy 167.099475 92.139475) (xy 167.1882 92.031363) + (xy 167.254128 91.90802) (xy 167.294727 91.774184) (xy 167.308435 91.635) (xy 167.305 91.600123) (xy 167.305 80.045) + (xy 170.881565 80.045) (xy 170.885001 80.079887) (xy 170.885 94.010123) (xy 170.881565 94.045) (xy 170.895273 94.184184) + (xy 170.935872 94.31802) (xy 171.0018 94.441363) (xy 171.090525 94.549475) (xy 171.198637 94.6382) (xy 171.32198 94.704128) + (xy 171.455816 94.744727) (xy 171.595 94.758435) (xy 171.629877 94.755) (xy 185.560123 94.755) (xy 185.595 94.758435) + (xy 185.629877 94.755) (xy 185.734184 94.744727) (xy 185.86802 94.704128) (xy 185.991363 94.6382) (xy 186.099475 94.549475) + (xy 186.1882 94.441363) (xy 186.254128 94.31802) (xy 186.294727 94.184184) (xy 186.308435 94.045) (xy 186.305 94.010123) + (xy 186.305 84.945) (xy 189.981565 84.945) (xy 189.985001 84.979887) (xy 189.985 98.910123) (xy 189.981565 98.945) + (xy 189.995273 99.084184) (xy 190.035872 99.21802) (xy 190.1018 99.341363) (xy 190.190525 99.449475) (xy 190.260715 99.507078) + (xy 190.298637 99.5382) (xy 190.42198 99.604128) (xy 190.555816 99.644727) (xy 190.695 99.658435) (xy 190.729877 99.655) + (xy 204.601011 99.655) (xy 204.349727 100.031072) (xy 204.124712 100.574308) (xy 204.01 101.151003) (xy 204.01 101.738997) + (xy 204.124712 102.315692) (xy 204.349727 102.858928) (xy 204.601011 103.235) (xy 190.729877 103.235) (xy 190.695 103.231565) + (xy 190.660123 103.235) (xy 190.555816 103.245273) (xy 190.42198 103.285872) (xy 190.298637 103.3518) (xy 190.190525 103.440525) + (xy 190.1018 103.548637) (xy 190.035872 103.67198) (xy 189.995273 103.805816) (xy 189.981565 103.945) (xy 189.985001 103.979887) + (xy 189.985 117.910123) (xy 189.981565 117.945) (xy 189.995273 118.084184) (xy 190.035872 118.21802) (xy 190.1018 118.341363) + (xy 190.190525 118.449475) (xy 190.274048 118.51802) (xy 190.298637 118.5382) (xy 190.42198 118.604128) (xy 190.555816 118.644727) + (xy 190.695 118.658435) (xy 190.729877 118.655) (xy 204.660123 118.655) (xy 204.695 118.658435) (xy 204.729877 118.655) + (xy 204.834184 118.644727) (xy 204.96802 118.604128) (xy 205.091363 118.5382) (xy 205.199475 118.449475) (xy 205.2882 118.341363) + (xy 205.354128 118.21802) (xy 205.394727 118.084184) (xy 205.408435 117.945) (xy 205.405 117.910123) (xy 205.405 103.979877) + (xy 205.40567 103.973073) (xy 205.581072 104.090273) (xy 206.124308 104.315288) (xy 206.701003 104.43) (xy 207.288997 104.43) + (xy 207.865692 104.315288) (xy 208.408928 104.090273) (xy 208.626343 103.945) (xy 209.031565 103.945) (xy 209.035001 103.979887) + (xy 209.035 117.910123) (xy 209.031565 117.945) (xy 209.045273 118.084184) (xy 209.085872 118.21802) (xy 209.1518 118.341363) + (xy 209.240525 118.449475) (xy 209.324048 118.51802) (xy 209.348637 118.5382) (xy 209.47198 118.604128) (xy 209.605816 118.644727) + (xy 209.745 118.658435) (xy 209.779877 118.655) (xy 223.710123 118.655) (xy 223.745 118.658435) (xy 223.779877 118.655) + (xy 223.884184 118.644727) (xy 224.01802 118.604128) (xy 224.141363 118.5382) (xy 224.249475 118.449475) (xy 224.3382 118.341363) + (xy 224.404128 118.21802) (xy 224.444727 118.084184) (xy 224.458435 117.945) (xy 224.455 117.910123) (xy 224.455 103.979877) + (xy 224.458435 103.945) (xy 224.444727 103.805816) (xy 224.404128 103.67198) (xy 224.3382 103.548637) (xy 224.249475 103.440525) + (xy 224.141363 103.3518) (xy 224.01802 103.285872) (xy 223.884184 103.245273) (xy 223.779877 103.235) (xy 223.745 103.231565) + (xy 223.710123 103.235) (xy 209.779877 103.235) (xy 209.745 103.231565) (xy 209.710123 103.235) (xy 209.605816 103.245273) + (xy 209.47198 103.285872) (xy 209.348637 103.3518) (xy 209.240525 103.440525) (xy 209.1518 103.548637) (xy 209.085872 103.67198) + (xy 209.045273 103.805816) (xy 209.031565 103.945) (xy 208.626343 103.945) (xy 208.897826 103.763601) (xy 209.313601 103.347826) + (xy 209.640273 102.858928) (xy 209.865288 102.315692) (xy 209.98 101.738997) (xy 209.98 101.151003) (xy 209.865288 100.574308) + (xy 209.640273 100.031072) (xy 209.317784 99.548434) (xy 209.42198 99.604128) (xy 209.555816 99.644727) (xy 209.695 99.658435) + (xy 209.729877 99.655) (xy 223.660123 99.655) (xy 223.695 99.658435) (xy 223.729877 99.655) (xy 223.834184 99.644727) + (xy 223.96802 99.604128) (xy 224.091363 99.5382) (xy 224.199475 99.449475) (xy 224.2882 99.341363) (xy 224.354128 99.21802) + (xy 224.394727 99.084184) (xy 224.408435 98.945) (xy 224.405 98.910123) (xy 224.405 84.979877) (xy 224.408435 84.945) + (xy 224.394727 84.805816) (xy 224.354128 84.67198) (xy 224.2882 84.548637) (xy 224.199475 84.440525) (xy 224.091363 84.3518) + (xy 223.96802 84.285872) (xy 223.834184 84.245273) (xy 223.729877 84.235) (xy 223.695 84.231565) (xy 223.660123 84.235) + (xy 209.729877 84.235) (xy 209.695 84.231565) (xy 209.660123 84.235) (xy 209.555816 84.245273) (xy 209.42198 84.285872) + (xy 209.298637 84.3518) (xy 209.190525 84.440525) (xy 209.1018 84.548637) (xy 209.035872 84.67198) (xy 208.995273 84.805816) + (xy 208.981565 84.945) (xy 208.985001 84.979887) (xy 208.985 98.910123) (xy 208.981565 98.945) (xy 208.995273 99.084184) + (xy 209.035872 99.21802) (xy 209.08918 99.317753) (xy 208.897826 99.126399) (xy 208.408928 98.799727) (xy 207.865692 98.574712) + (xy 207.288997 98.46) (xy 206.701003 98.46) (xy 206.124308 98.574712) (xy 205.581072 98.799727) (xy 205.40567 98.916927) + (xy 205.405 98.910123) (xy 205.405 84.979877) (xy 205.408435 84.945) (xy 205.394727 84.805816) (xy 205.354128 84.67198) + (xy 205.2882 84.548637) (xy 205.199475 84.440525) (xy 205.091363 84.3518) (xy 204.96802 84.285872) (xy 204.834184 84.245273) + (xy 204.729877 84.235) (xy 204.695 84.231565) (xy 204.660123 84.235) (xy 190.729877 84.235) (xy 190.695 84.231565) + (xy 190.660123 84.235) (xy 190.555816 84.245273) (xy 190.42198 84.285872) (xy 190.298637 84.3518) (xy 190.190525 84.440525) + (xy 190.1018 84.548637) (xy 190.035872 84.67198) (xy 189.995273 84.805816) (xy 189.981565 84.945) (xy 186.305 84.945) + (xy 186.305 80.079877) (xy 186.308435 80.045) (xy 186.294727 79.905816) (xy 186.254128 79.77198) (xy 186.1882 79.648637) + (xy 186.099475 79.540525) (xy 185.991363 79.4518) (xy 185.86802 79.385872) (xy 185.734184 79.345273) (xy 185.629877 79.335) + (xy 185.595 79.331565) (xy 185.560123 79.335) (xy 171.629877 79.335) (xy 171.595 79.331565) (xy 171.560123 79.335) + (xy 171.455816 79.345273) (xy 171.32198 79.385872) (xy 171.198637 79.4518) (xy 171.090525 79.540525) (xy 171.0018 79.648637) + (xy 170.935872 79.77198) (xy 170.895273 79.905816) (xy 170.881565 80.045) (xy 167.305 80.045) (xy 167.305 77.669877) + (xy 167.308435 77.635) (xy 167.294727 77.495816) (xy 167.254128 77.36198) (xy 167.1882 77.238637) (xy 167.099475 77.130525) + (xy 166.991363 77.0418) (xy 166.86802 76.975872) (xy 166.734184 76.935273) (xy 166.629877 76.925) (xy 166.595 76.921565) + (xy 166.560123 76.925) (xy 152.629877 76.925) (xy 152.595 76.921565) (xy 152.560123 76.925) (xy 152.455816 76.935273) + (xy 152.32198 76.975872) (xy 152.198637 77.0418) (xy 152.090525 77.130525) (xy 152.0018 77.238637) (xy 151.935872 77.36198) + (xy 151.895273 77.495816) (xy 151.881565 77.635) (xy 151.7875 77.635) (xy 151.7875 61.837619) (xy 148.8675 61.837619) + (xy 148.205 61.837619) (xy 148.205 61.079877) (xy 148.208435 61.045) (xy 148.194727 60.905816) (xy 148.154128 60.77198) + (xy 148.0882 60.648637) (xy 147.999475 60.540525) (xy 147.891363 60.4518) (xy 147.76802 60.385872) (xy 147.634184 60.345273) + (xy 147.529877 60.335) (xy 147.495 60.331565) (xy 147.460123 60.335) (xy 133.529877 60.335) (xy 133.495 60.331565) + (xy 133.460123 60.335) (xy 133.355816 60.345273) (xy 133.298884 60.362543) (xy 133.313601 60.347826) (xy 133.640273 59.858928) + (xy 133.865288 59.315692) (xy 133.98 58.738997) (xy 133.98 58.535) (xy 151.881565 58.535) (xy 151.885001 58.569887) + (xy 151.885 72.500123) (xy 151.881565 72.535) (xy 151.895273 72.674184) (xy 151.935872 72.80802) (xy 152.0018 72.931363) + (xy 152.090525 73.039475) (xy 152.198637 73.1282) (xy 152.32198 73.194128) (xy 152.455816 73.234727) (xy 152.595 73.248435) + (xy 152.629877 73.245) (xy 166.560123 73.245) (xy 166.595 73.248435) (xy 166.629877 73.245) (xy 166.734184 73.234727) + (xy 166.86802 73.194128) (xy 166.991363 73.1282) (xy 167.099475 73.039475) (xy 167.1882 72.931363) (xy 167.254128 72.80802) + (xy 167.294727 72.674184) (xy 167.308435 72.535) (xy 167.305 72.500123) (xy 167.305 60.985) (xy 170.881565 60.985) + (xy 170.885001 61.019887) (xy 170.885 74.950123) (xy 170.881565 74.985) (xy 170.895273 75.124184) (xy 170.935872 75.25802) + (xy 171.0018 75.381363) (xy 171.090525 75.489475) (xy 171.198637 75.5782) (xy 171.32198 75.644128) (xy 171.455816 75.684727) + (xy 171.595 75.698435) (xy 171.629877 75.695) (xy 185.560123 75.695) (xy 185.595 75.698435) (xy 185.629877 75.695) + (xy 185.734184 75.684727) (xy 185.86802 75.644128) (xy 185.991363 75.5782) (xy 186.099475 75.489475) (xy 186.1882 75.381363) + (xy 186.254128 75.25802) (xy 186.294727 75.124184) (xy 186.308435 74.985) (xy 186.305 74.950123) (xy 186.305 61.019877) + (xy 186.308435 60.985) (xy 186.294727 60.845816) (xy 186.254128 60.71198) (xy 186.1882 60.588637) (xy 186.099475 60.480525) + (xy 185.991363 60.3918) (xy 185.86802 60.325872) (xy 185.734184 60.285273) (xy 185.629877 60.275) (xy 185.595 60.271565) + (xy 185.560123 60.275) (xy 171.629877 60.275) (xy 171.595 60.271565) (xy 171.560123 60.275) (xy 171.455816 60.285273) + (xy 171.32198 60.325872) (xy 171.198637 60.3918) (xy 171.090525 60.480525) (xy 171.0018 60.588637) (xy 170.935872 60.71198) + (xy 170.895273 60.845816) (xy 170.881565 60.985) (xy 167.305 60.985) (xy 167.305 58.569877) (xy 167.308435 58.535) + (xy 167.294727 58.395816) (xy 167.254128 58.26198) (xy 167.1882 58.138637) (xy 167.099475 58.030525) (xy 166.991363 57.9418) + (xy 166.86802 57.875872) (xy 166.734184 57.835273) (xy 166.629877 57.825) (xy 166.595 57.821565) (xy 166.560123 57.825) + (xy 152.629877 57.825) (xy 152.595 57.821565) (xy 152.560123 57.825) (xy 152.455816 57.835273) (xy 152.32198 57.875872) + (xy 152.198637 57.9418) (xy 152.090525 58.030525) (xy 152.0018 58.138637) (xy 151.935872 58.26198) (xy 151.895273 58.395816) + (xy 151.881565 58.535) (xy 133.98 58.535) (xy 133.98 58.151003) (xy 133.865288 57.574308) (xy 133.640273 57.031072) + (xy 133.383978 56.647501) (xy 133.495 56.658435) (xy 133.529877 56.655) (xy 147.460123 56.655) (xy 147.495 56.658435) + (xy 147.529877 56.655) (xy 147.634184 56.644727) (xy 147.76802 56.604128) (xy 147.891363 56.5382) (xy 147.999475 56.449475) + (xy 148.0882 56.341363) (xy 148.154128 56.21802) (xy 148.194727 56.084184) (xy 148.208435 55.945) (xy 148.205 55.910123) + (xy 148.205 41.979877) (xy 148.208435 41.945) (xy 148.194727 41.805816) (xy 148.154128 41.67198) (xy 148.0882 41.548637) + (xy 147.999475 41.440525) (xy 147.891363 41.3518) (xy 147.76802 41.285872) (xy 147.634184 41.245273) (xy 147.529877 41.235) + (xy 147.495 41.231565) (xy 147.460123 41.235) (xy 133.529877 41.235) (xy 133.495 41.231565) (xy 133.460123 41.235) + (xy 133.355816 41.245273) (xy 133.22198 41.285872) (xy 133.098637 41.3518) (xy 132.990525 41.440525) (xy 132.9018 41.548637) + (xy 132.835872 41.67198) (xy 132.795273 41.805816) (xy 132.781565 41.945) (xy 132.785001 41.979887) (xy 132.785 55.910123) + (xy 132.781565 55.945) (xy 132.792499 56.056022) (xy 132.408928 55.799727) (xy 131.865692 55.574712) (xy 131.288997 55.46) + (xy 130.701003 55.46) (xy 130.124308 55.574712) (xy 129.581072 55.799727) (xy 129.205 56.051011) (xy 129.205 44.479877) + (xy 129.208435 44.445) (xy 129.194727 44.305816) (xy 129.154128 44.17198) (xy 129.0882 44.048637) (xy 128.999475 43.940525) + (xy 128.891363 43.8518) (xy 128.76802 43.785872) (xy 128.634184 43.745273) (xy 128.529877 43.735) (xy 128.495 43.731565) + (xy 128.460123 43.735) (xy 114.529877 43.735) (xy 114.495 43.731565) (xy 114.460123 43.735) (xy 114.355816 43.745273) + (xy 114.22198 43.785872) (xy 114.098637 43.8518) (xy 113.990525 43.940525) (xy 113.9018 44.048637) (xy 113.835872 44.17198) + (xy 113.795273 44.305816) (xy 113.781565 44.445) (xy 112.705 44.445) (xy 112.705 39.445) (xy 151.881565 39.445) + (xy 151.885001 39.479887) (xy 151.885 53.410123) (xy 151.881565 53.445) (xy 151.895273 53.584184) (xy 151.935872 53.71802) + (xy 152.0018 53.841363) (xy 152.090525 53.949475) (xy 152.198637 54.0382) (xy 152.32198 54.104128) (xy 152.455816 54.144727) + (xy 152.595 54.158435) (xy 152.629877 54.155) (xy 166.560123 54.155) (xy 166.595 54.158435) (xy 166.629877 54.155) + (xy 166.734184 54.144727) (xy 166.86802 54.104128) (xy 166.991363 54.0382) (xy 167.099475 53.949475) (xy 167.1882 53.841363) + (xy 167.254128 53.71802) (xy 167.294727 53.584184) (xy 167.308435 53.445) (xy 167.305 53.410123) (xy 167.305 41.985) + (xy 170.881565 41.985) (xy 170.885001 42.019887) (xy 170.885 55.950123) (xy 170.881565 55.985) (xy 170.895273 56.124184) + (xy 170.935872 56.25802) (xy 171.0018 56.381363) (xy 171.090525 56.489475) (xy 171.198637 56.5782) (xy 171.32198 56.644128) + (xy 171.455816 56.684727) (xy 171.595 56.698435) (xy 171.629877 56.695) (xy 185.560123 56.695) (xy 185.595 56.698435) + (xy 185.629877 56.695) (xy 185.734184 56.684727) (xy 185.86802 56.644128) (xy 185.991363 56.5782) (xy 186.099475 56.489475) + (xy 186.1882 56.381363) (xy 186.254128 56.25802) (xy 186.294727 56.124184) (xy 186.308435 55.985) (xy 186.305 55.950123) + (xy 186.305 46.845) (xy 189.981565 46.845) (xy 189.985001 46.879887) (xy 189.985 60.810123) (xy 189.981565 60.845) + (xy 189.995273 60.984184) (xy 190.035872 61.11802) (xy 190.1018 61.241363) (xy 190.190525 61.349475) (xy 190.288645 61.43) + (xy 190.298637 61.4382) (xy 190.42198 61.504128) (xy 190.555816 61.544727) (xy 190.695 61.558435) (xy 190.729877 61.555) + (xy 204.339816 61.555) (xy 204.124712 62.074308) (xy 204.01 62.651003) (xy 204.01 63.238997) (xy 204.124712 63.815692) + (xy 204.349727 64.358928) (xy 204.676399 64.847826) (xy 204.891116 65.062543) (xy 204.834184 65.045273) (xy 204.729877 65.035) + (xy 204.695 65.031565) (xy 204.660123 65.035) (xy 190.729877 65.035) (xy 190.695 65.031565) (xy 190.660123 65.035) + (xy 190.555816 65.045273) (xy 190.42198 65.085872) (xy 190.298637 65.1518) (xy 190.190525 65.240525) (xy 190.1018 65.348637) + (xy 190.035872 65.47198) (xy 189.995273 65.605816) (xy 189.981565 65.745) (xy 189.985001 65.779887) (xy 189.985 79.710123) + (xy 189.981565 79.745) (xy 189.995273 79.884184) (xy 190.035872 80.01802) (xy 190.1018 80.141363) (xy 190.190525 80.249475) + (xy 190.274048 80.31802) (xy 190.298637 80.3382) (xy 190.42198 80.404128) (xy 190.555816 80.444727) (xy 190.695 80.458435) + (xy 190.729877 80.455) (xy 204.660123 80.455) (xy 204.695 80.458435) (xy 204.729877 80.455) (xy 204.834184 80.444727) + (xy 204.96802 80.404128) (xy 205.091363 80.3382) (xy 205.199475 80.249475) (xy 205.2882 80.141363) (xy 205.354128 80.01802) + (xy 205.394727 79.884184) (xy 205.408435 79.745) (xy 205.405 79.710123) (xy 205.405 65.779877) (xy 205.408435 65.745) + (xy 205.394727 65.605816) (xy 205.354128 65.47198) (xy 205.326401 65.420107) (xy 205.581072 65.590273) (xy 206.124308 65.815288) + (xy 206.701003 65.93) (xy 207.288997 65.93) (xy 207.865692 65.815288) (xy 208.035382 65.745) (xy 208.981565 65.745) + (xy 208.985001 65.779887) (xy 208.985 79.710123) (xy 208.981565 79.745) (xy 208.995273 79.884184) (xy 209.035872 80.01802) + (xy 209.1018 80.141363) (xy 209.190525 80.249475) (xy 209.274048 80.31802) (xy 209.298637 80.3382) (xy 209.42198 80.404128) + (xy 209.555816 80.444727) (xy 209.695 80.458435) (xy 209.729877 80.455) (xy 223.660123 80.455) (xy 223.695 80.458435) + (xy 223.729877 80.455) (xy 223.834184 80.444727) (xy 223.96802 80.404128) (xy 224.091363 80.3382) (xy 224.199475 80.249475) + (xy 224.2882 80.141363) (xy 224.354128 80.01802) (xy 224.394727 79.884184) (xy 224.408435 79.745) (xy 224.405 79.710123) + (xy 224.405 65.779877) (xy 224.408435 65.745) (xy 224.394727 65.605816) (xy 224.354128 65.47198) (xy 224.2882 65.348637) + (xy 224.199475 65.240525) (xy 224.091363 65.1518) (xy 223.96802 65.085872) (xy 223.834184 65.045273) (xy 223.729877 65.035) + (xy 223.695 65.031565) (xy 223.660123 65.035) (xy 209.729877 65.035) (xy 209.695 65.031565) (xy 209.660123 65.035) + (xy 209.555816 65.045273) (xy 209.42198 65.085872) (xy 209.298637 65.1518) (xy 209.190525 65.240525) (xy 209.1018 65.348637) + (xy 209.035872 65.47198) (xy 208.995273 65.605816) (xy 208.981565 65.745) (xy 208.035382 65.745) (xy 208.408928 65.590273) + (xy 208.897826 65.263601) (xy 209.313601 64.847826) (xy 209.640273 64.358928) (xy 209.865288 63.815692) (xy 209.98 63.238997) + (xy 209.98 62.651003) (xy 209.865288 62.074308) (xy 209.649762 61.55398) (xy 209.695 61.558435) (xy 209.729877 61.555) + (xy 223.660123 61.555) (xy 223.695 61.558435) (xy 223.729877 61.555) (xy 223.834184 61.544727) (xy 223.96802 61.504128) + (xy 224.091363 61.4382) (xy 224.199475 61.349475) (xy 224.2882 61.241363) (xy 224.354128 61.11802) (xy 224.394727 60.984184) + (xy 224.408435 60.845) (xy 224.405 60.810123) (xy 224.405 46.879877) (xy 224.408435 46.845) (xy 224.394727 46.705816) + (xy 224.354128 46.57198) (xy 224.2882 46.448637) (xy 224.199475 46.340525) (xy 224.091363 46.2518) (xy 223.96802 46.185872) + (xy 223.834184 46.145273) (xy 223.729877 46.135) (xy 223.695 46.131565) (xy 223.660123 46.135) (xy 209.729877 46.135) + (xy 209.695 46.131565) (xy 209.660123 46.135) (xy 209.555816 46.145273) (xy 209.42198 46.185872) (xy 209.298637 46.2518) + (xy 209.190525 46.340525) (xy 209.1018 46.448637) (xy 209.035872 46.57198) (xy 208.995273 46.705816) (xy 208.981565 46.845) + (xy 208.985001 46.879887) (xy 208.985 60.713573) (xy 208.897826 60.626399) (xy 208.408928 60.299727) (xy 207.865692 60.074712) + (xy 207.288997 59.96) (xy 206.701003 59.96) (xy 206.124308 60.074712) (xy 205.581072 60.299727) (xy 205.405 60.417375) + (xy 205.405 46.879877) (xy 205.408435 46.845) (xy 205.394727 46.705816) (xy 205.354128 46.57198) (xy 205.2882 46.448637) + (xy 205.199475 46.340525) (xy 205.091363 46.2518) (xy 204.96802 46.185872) (xy 204.834184 46.145273) (xy 204.729877 46.135) + (xy 204.695 46.131565) (xy 204.660123 46.135) (xy 190.729877 46.135) (xy 190.695 46.131565) (xy 190.660123 46.135) + (xy 190.555816 46.145273) (xy 190.42198 46.185872) (xy 190.298637 46.2518) (xy 190.190525 46.340525) (xy 190.1018 46.448637) + (xy 190.035872 46.57198) (xy 189.995273 46.705816) (xy 189.981565 46.845) (xy 186.305 46.845) (xy 186.305 42.019877) + (xy 186.308435 41.985) (xy 186.294727 41.845816) (xy 186.254128 41.71198) (xy 186.1882 41.588637) (xy 186.099475 41.480525) + (xy 185.991363 41.3918) (xy 185.86802 41.325872) (xy 185.734184 41.285273) (xy 185.629877 41.275) (xy 185.595 41.271565) + (xy 185.560123 41.275) (xy 171.629877 41.275) (xy 171.595 41.271565) (xy 171.560123 41.275) (xy 171.455816 41.285273) + (xy 171.32198 41.325872) (xy 171.198637 41.3918) (xy 171.090525 41.480525) (xy 171.0018 41.588637) (xy 170.935872 41.71198) + (xy 170.895273 41.845816) (xy 170.881565 41.985) (xy 167.305 41.985) (xy 167.305 39.479877) (xy 167.308435 39.445) + (xy 167.294727 39.305816) (xy 167.254128 39.17198) (xy 167.1882 39.048637) (xy 167.099475 38.940525) (xy 166.991363 38.8518) + (xy 166.86802 38.785872) (xy 166.734184 38.745273) (xy 166.629877 38.735) (xy 166.595 38.731565) (xy 166.560123 38.735) + (xy 152.629877 38.735) (xy 152.595 38.731565) (xy 152.560123 38.735) (xy 152.455816 38.745273) (xy 152.32198 38.785872) + (xy 152.198637 38.8518) (xy 152.090525 38.940525) (xy 152.0018 39.048637) (xy 151.935872 39.17198) (xy 151.895273 39.305816) + (xy 151.881565 39.445) (xy 112.705 39.445) (xy 112.705 39.145821) (xy 112.746463 39.002775) (xy 112.846756 38.852335) + (xy 112.915575 38.783516) (xy 112.967387 38.75761) (xy 113.193645 38.68219) (xy 113.601036 38.580342) (xy 113.61046 38.576975) + (xy 150.008615 37.13) (xy 171.891299 37.13) + ) + ) + ) +) diff --git a/Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.pro b/Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.pro new file mode 100644 index 00000000..3f0da368 --- /dev/null +++ b/Sofle_RGB_v3/Case/PCBTop/SofleKeyboardTopPlate.pro @@ -0,0 +1,61 @@ + +update=2018 March 15, Thursday 14:41:19 +version=1 +last_client=kicad +[pcbnew] +version=1 +LastNetListRead= +UseCmpFile=1 +PadDrill=0.600000000000 +PadDrillOvalY=0.600000000000 +PadSizeH=1.500000000000 +PadSizeV=1.500000000000 +PcbTextSizeV=1.500000000000 +PcbTextSizeH=1.500000000000 +PcbTextThickness=0.300000000000 +ModuleTextSizeV=1.000000000000 +ModuleTextSizeH=1.000000000000 +ModuleTextSizeThickness=0.150000000000 +SolderMaskClearance=0.000000000000 +SolderMaskMinWidth=0.000000000000 +DrawSegmentWidth=0.200000000000 +BoardOutlineThickness=0.100000000000 +ModuleOutlineThickness=0.150000000000 +[cvpcb] +version=1 +NetIExt=net +[general] +version=1 +[eeschema] +version=1 +LibDir= +[eeschema/libraries] +LibName1=power +LibName2=device +LibName3=transistors +LibName4=conn +LibName5=linear +LibName6=regul +LibName7=74xx +LibName8=cmos4000 +LibName9=adc-dac +LibName10=memory +LibName11=xilinx +LibName12=microcontrollers +LibName13=dsp +LibName14=microchip +LibName15=analog_switches +LibName16=motorola +LibName17=texas +LibName18=intel +LibName19=audio +LibName20=interface +LibName21=digital-audio +LibName22=philips +LibName23=display +LibName24=cypress +LibName25=siliconi +LibName26=opto +LibName27=atmel +LibName28=contrib +LibName29=valves diff --git a/Sofle_RGB_v3/Case/PCBTop/fp-info-cache b/Sofle_RGB_v3/Case/PCBTop/fp-info-cache new file mode 100644 index 00000000..1dddc92e --- /dev/null +++ b/Sofle_RGB_v3/Case/PCBTop/fp-info-cache @@ -0,0 +1,83042 @@ +19084952703475187 +Battery +BatteryHolder_Bulgin_BX0036_1xC +Bulgin Battery Holder, BX0036, Battery Type C (https://www.bulgin.com/products/pub/media/bulgin/data/Battery_holders.pdf) +Bulgin BX0036 +0 +2 +2 +Battery +BatteryHolder_ComfortableElectronic_CH273-2450_1x2450 +Comfortable Electronic CR2450 battery holder, http://www.comf.com.tw/ProductDetail.asp?no=148 +Comfortable Electronic CR2450 +0 +2 +2 +Battery +BatteryHolder_Eagle_12BH611-GR +https://eu.mouser.com/datasheet/2/209/EPD-200766-1274481.pdf +9V Battery Holder +0 +2 +2 +Battery +BatteryHolder_Keystone_103_1x20mm +http://www.keyelco.com/product-pdf.cfm?p=719 +Keystone type 103 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_104_1x23mm +http://www.keyelco.com/product-pdf.cfm?p=744 +Keystone type 104 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_105_1x2430 +http://www.keyelco.com/product-pdf.cfm?p=745 +Keystone type 105 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_106_1x20mm +http://www.keyelco.com/product-pdf.cfm?p=720 +Keystone type 106 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_107_1x23mm +http://www.keyelco.com/product-pdf.cfm?p=746 +Keystone type 107 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_500 +Keystone #500, CR1220 battery holder, http://www.keyelco.com/product-pdf.cfm?p=710 +CR1220 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_1042_1x18650 +Battery holder for 18650 cylindrical cells http://www.keyelco.com/product.cfm/product_id/918 +18650 Keystone 1042 Li-ion +0 +2 +2 +Battery +BatteryHolder_Keystone_1058_1x2032 +http://www.keyelco.com/product-pdf.cfm?p=14028 +Keystone type 1058 coin cell retainer +0 +2 +2 +Battery +BatteryHolder_Keystone_1060_1x2032 +http://www.keyelco.com/product-pdf.cfm?p=726 +CR2032 BR2032 BatteryHolder Battery +0 +2 +2 +Battery +BatteryHolder_Keystone_2460_1xAA +https://www.keyelco.com/product-pdf.cfm?p=1025 +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2462_2xAA +2xAA cell battery holder, Keystone P/N 2462, https://www.keyelco.com/product-pdf.cfm?p=1027 +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2466_1xAAA +1xAAA Battery Holder, Keystone, Plastic Case, http://www.keyelco.com/product-pdf.cfm?p=1031 +AAA battery holder Keystone +0 +2 +2 +Battery +BatteryHolder_Keystone_2468_2xAAA +2xAAA cell battery holder, Keystone P/N 2468, http://www.keyelco.com/product-pdf.cfm?p=1033 +AAA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2479_3xAAA +Keystone Battery Holder, 2479, Battery Type 3xAAA (Script generated with StandardBox.py) (Keystone Battery Holder, 2479, Battery Type 3xAAA) +Keystone Battery Holder 2479 Battery Type 3xAAA +0 +2 +2 +Battery +BatteryHolder_Keystone_2993 +http://www.keyelco.com/product-pdf.cfm?p=776 +Keystone type 2993 negative battery contact +0 +1 +1 +Battery +BatteryHolder_Keystone_2998_1x6.8mm +www.keyelco.com/product-pdf.cfm?p=763 +Keystone type 2998 battery holder +0 +3 +2 +Battery +BatteryHolder_Keystone_3000_1x12mm +http://www.keyelco.com/product-pdf.cfm?p=777 +Keystone type 3000 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3001_1x12mm +http://www.keyelco.com/product-pdf.cfm?p=778 +Keystone type 3001 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3002_1x2032 +https://www.tme.eu/it/Document/a823211ec201a9e209042d155fe22d2b/KEYS2996.pdf +BR2016 CR2016 DL2016 BR2020 CL2020 BR2025 CR2025 DL2025 DR2032 CR2032 DL2032 +0 +3 +2 +Battery +BatteryHolder_Keystone_3008_1x2450 +http://www.keyelco.com/product-pdf.cfm?p=786 +Keystone type 3008 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3009_1x2450 +http://www.keyelco.com/product-pdf.cfm?p=787 +Keystone type 3009 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3034_1x20mm +Keystone 3034 SMD battery holder for 2020, 2025 and 2032 coincell batteries. http://www.keyelco.com/product-pdf.cfm?p=798 +Keystone type 3034 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_LINX_BAT-HLD-012-SMT +SMT battery holder for CR1216/1220/1225, https://linxtechnologies.com/wp/wp-content/uploads/bat-hld-012-smt.pdf +battery holder coin cell cr1216 cr1220 cr1225 +0 +3 +2 +Battery +BatteryHolder_MPD_BA9VPC_1xPP3 +1xPP3 (9V) battery holder, Memory Protection Devices P/N BA9VPC, http://www.memoryprotectiondevices.com/datasheets/BA9VPC-datasheet.pdf +PP3 Battery Holder BA9VPC 9V +0 +2 +2 +Battery +BatteryHolder_MPD_BC2AAPC_2xAA +2xAA cell battery holder, Memory Protection Devices P/N BC2AAPC, http://www.memoryprotectiondevices.com/datasheets/BC2AAPC-datasheet.pdf +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_MPD_BC12AAPC_2xAA +2xAA cell battery holder, Memory Protection Devices P/N BC12AAPC, http://www.memoryprotectiondevices.com/datasheets/BC12AAPC-datasheet.pdf +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_MPD_BC2003_1x2032 +http://www.memoryprotectiondevices.com/datasheets/BC-2003-datasheet.pdf +BC2003 CR2032 2032 Battery Holder +0 +3 +2 +Battery +BatteryHolder_MPD_BH-18650-PC2 +18650 Battery Holder (http://www.memoryprotectiondevices.com/datasheets/BK-18650-PC2-datasheet.pdf) +18650 Battery Holder +0 +2 +2 +Battery +BatteryHolder_Seiko_MS621F +Seiko MS621F, https://www.sii.co.jp/en/me/files/2014/02/file_EXTENDED_PRDCT_SPEC_75_FILE_11.jpg +Seiko MS621F +0 +2 +2 +Battery +BatteryHolder_TruPower_BH-331P_3xAA +Keystone Battery Holder BH-331P Battery Type 3xAA (Script generated with StandardBox.py) (Keystone Battery Holder BH-331P Battery Type 3xAA) +Battery Holder BH-331P Battery Type 3xAA +0 +2 +2 +Battery +Battery_CR1225 +CR1225 battery +battery CR1225 coin cell +0 +0 +0 +Battery +Battery_Panasonic_CR1025-VSK_Vertical_CircularHoles +Panasonic CR-1025/VSK battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-1025 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR1220-VCN_Vertical_CircularHoles +Panasonic CR-1220/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-1220 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR1632-V1AN_Vertical_CircularHoles +Panasonic CR-1632-V1AN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-1632 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2025-V1AK_Vertical_CircularHoles +Panasonic CR-2025/V1AK battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2025 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2032-VS1N_Vertical_CircularHoles +Panasonic CR-2032/VS1N battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2032 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2354-VCN_Vertical_CircularHoles +Panasonic CR-2354/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2354/VCN coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2450-VAN_Vertical_CircularHoles +Panasonic CR-2450/VAN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2450 coin cell +0 +2 +2 +Battery +Battery_Panasonic_CR2477-VCN_Vertical_CircularHoles +Panasonic CR-2477/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2477 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR3032-VCN_Vertical_CircularHoles +Panasonic CR-3032/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-3032 coin cell vertical +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.00u_PCB +Cherry MX keyswitch, 1.00u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.00u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.00u_Plate +Cherry MX keyswitch, 1.00u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.00u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.25u_PCB +Cherry MX keyswitch, 1.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.25u_Plate +Cherry MX keyswitch, 1.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.50u_PCB +Cherry MX keyswitch, 1.50u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.50u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.50u_Plate +Cherry MX keyswitch, 1.50u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.50u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.75u_PCB +Cherry MX keyswitch, 1.75u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.75u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.75u_Plate +Cherry MX keyswitch, 1.75u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.75u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_PCB +Cherry MX keyswitch, 2.00u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Plate +Cherry MX keyswitch, 2.00u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Vertical_PCB +Cherry MX keyswitch, 2.00u, vertical, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u vertical PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Vertical_Plate +Cherry MX keyswitch, 2.00u, vertical, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u vertical plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.25u_PCB +Cherry MX keyswitch, 2.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.25u_Plate +Cherry MX keyswitch, 2.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.75u_PCB +Cherry MX keyswitch, 2.75u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.75u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.75u_Plate +Cherry MX keyswitch, 2.75u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.75u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_6.25u_PCB +Cherry MX keyswitch, 6.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 6.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_6.25u_Plate +Cherry MX keyswitch, 6.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 6.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_ISOEnter_PCB +Cherry MX keyswitch, ISO Enter, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch ISO enter PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_ISOEnter_Plate +Cherry MX keyswitch, ISO Enter, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch ISO enter plate +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.00u +Matias/ALPS keyswitch, 1.00u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.00u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.25u +Matias/ALPS keyswitch, 1.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.50u +Matias/ALPS keyswitch, 1.50u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.50u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.75u +Matias/ALPS keyswitch, 1.75u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.75u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.00u +Matias/ALPS keyswitch, 2.00u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.00u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.25u +Matias/ALPS keyswitch, 2.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.75u +Matias/ALPS keyswitch, 2.75u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.75u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_6.25u +Matias/ALPS keyswitch, 6.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 6.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_ISOEnter +Matias/ALPS keyswitch, ISO Enter, http://matias.ca/switches/ +Matias ALPS keyswitch ISO enter +0 +2 +2 +Button_Switch_SMD +Nidec_Copal_SH-7010A +4-bit rotary coded switch, J-hook, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_SMD +Nidec_Copal_SH-7010B +4-bit rotary coded switch, gull wing, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_SMD +Nidec_Copal_SH-7040B +4-bit rotary coded switch, gull wing, Gray code, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +5 +5 +Button_Switch_SMD +Panasonic_EVQPUJ_EVQPUA +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUJ EVQPUA +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUK_EVQPUB +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUK EVQPUB +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUL_EVQPUC +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUL EVQPUC +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUM_EVQPUD +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUM EVQPUD +0 +4 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 1x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W8.61mm_P2.54mm_LowProfile +SMD 1x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_9.78x4.72mm_W8.61mm_P2.54mm +SMD 1x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x4.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CHS-01A_W5.08mm_P1.27mm_JPin +SMD 1x-dip-switch SPST Copal_CHS-01A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CHS-01B_W7.62mm_P1.27mm +SMD 1x-dip-switch SPST Copal_CHS-01B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CVS-01xB_W5.9mm_P1mm +SMD 1x-dip-switch SPST Copal_CVS-01xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +6 +3 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Omron_A6S-110x_W8.9mm_P2.54mm +SMD 1x-dip-switch SPST Omron_A6S-110x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 2x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W8.61mm_P2.54mm_LowProfile +SMD 2x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_9.78x7.26mm_W8.61mm_P2.54mm +SMD 2x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x7.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CHS-02A_W5.08mm_P1.27mm_JPin +SMD 2x-dip-switch SPST Copal_CHS-02A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CHS-02B_W7.62mm_P1.27mm +SMD 2x-dip-switch SPST Copal_CHS-02B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CVS-02xB_W5.9mm_P1mm +SMD 2x-dip-switch SPST Copal_CVS-02xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +8 +5 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_KingTek_DSHP02TJ_W5.25mm_P1.27mm_JPin +SMD 2x-dip-switch SPST KingTek_DSHP02TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_KingTek_DSHP02TS_W7.62mm_P1.27mm +SMD 2x-dip-switch SPST KingTek_DSHP02TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Omron_A6H-2101_W6.15mm_P1.27mm +SMD 2x-dip-switch SPST Omron_A6H-2101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Omron_A6S-210x_W8.9mm_P2.54mm +SMD 2x-dip-switch SPST Omron_A6S-210x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 3x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W8.61mm_P2.54mm_LowProfile +SMD 3x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_9.78x9.8mm_W8.61mm_P2.54mm +SMD 3x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x9.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_Copal_CVS-03xB_W5.9mm_P1mm +SMD 3x-dip-switch SPST Copal_CVS-03xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +10 +7 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_KingTek_DSHP03TJ_W5.25mm_P1.27mm_JPin +SMD 3x-dip-switch SPST KingTek_DSHP03TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_KingTek_DSHP03TS_W7.62mm_P1.27mm +SMD 3x-dip-switch SPST KingTek_DSHP03TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_Omron_A6S-310x_W8.9mm_P2.54mm +SMD 3x-dip-switch SPST Omron_A6S-310x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 4x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W8.61mm_P2.54mm_LowProfile +SMD 4x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_9.78x12.34mm_W8.61mm_P2.54mm +SMD 4x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x12.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CHS-04A_W5.08mm_P1.27mm_JPin +SMD 4x-dip-switch SPST Copal_CHS-04A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CHS-04B_W7.62mm_P1.27mm +SMD 4x-dip-switch SPST Copal_CHS-04B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CVS-04xB_W5.9mm_P1mm +SMD 4x-dip-switch SPST Copal_CVS-04xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +12 +9 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_KingTek_DSHP04TJ_W5.25mm_P1.27mm_JPin +SMD 4x-dip-switch SPST KingTek_DSHP04TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_KingTek_DSHP04TS_W7.62mm_P1.27mm +SMD 4x-dip-switch SPST KingTek_DSHP04TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Omron_A6H-4101_W6.15mm_P1.27mm +SMD 4x-dip-switch SPST Omron_A6H-4101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Omron_A6S-410x_W8.9mm_P2.54mm +SMD 4x-dip-switch SPST Omron_A6S-410x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 5x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W8.61mm_P2.54mm_LowProfile +SMD 5x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_9.78x14.88mm_W8.61mm_P2.54mm +SMD 5x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x14.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_KingTek_DSHP05TJ_W5.25mm_P1.27mm_JPin +SMD 5x-dip-switch SPST KingTek_DSHP05TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_KingTek_DSHP05TS_W7.62mm_P1.27mm +SMD 5x-dip-switch SPST KingTek_DSHP05TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_Omron_A6S-510x_W8.9mm_P2.54mm +SMD 5x-dip-switch SPST Omron_A6S-510x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 6x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W8.61mm_P2.54mm_LowProfile +SMD 6x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_9.78x17.42mm_W8.61mm_P2.54mm +SMD 6x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x17.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Copal_CHS-06A_W5.08mm_P1.27mm_JPin +SMD 6x-dip-switch SPST Copal_CHS-06A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Copal_CHS-06B_W7.62mm_P1.27mm +SMD 6x-dip-switch SPST Copal_CHS-06B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_KingTek_DSHP06TJ_W5.25mm_P1.27mm_JPin +SMD 6x-dip-switch SPST KingTek_DSHP06TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_KingTek_DSHP06TS_W7.62mm_P1.27mm +SMD 6x-dip-switch SPST KingTek_DSHP06TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Omron_A6H-6101_W6.15mm_P1.27mm +SMD 6x-dip-switch SPST Omron_A6H-6101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Omron_A6S-610x_W8.9mm_P2.54mm +SMD 6x-dip-switch SPST Omron_A6S-610x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 7x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W8.61mm_P2.54mm_LowProfile +SMD 7x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_9.78x19.96mm_W8.61mm_P2.54mm +SMD 7x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x19.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_KingTek_DSHP07TJ_W5.25mm_P1.27mm_JPin +SMD 7x-dip-switch SPST KingTek_DSHP07TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_KingTek_DSHP07TS_W7.62mm_P1.27mm +SMD 7x-dip-switch SPST KingTek_DSHP07TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_Omron_A6S-710x_W8.9mm_P2.54mm +SMD 7x-dip-switch SPST Omron_A6S-710x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 8x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W8.61mm_P2.54mm_LowProfile +SMD 8x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_9.78x22.5mm_W8.61mm_P2.54mm +SMD 8x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x22.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CHS-08A_W5.08mm_P1.27mm_JPin +SMD 8x-dip-switch SPST Copal_CHS-08A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CHS-08B_W7.62mm_P1.27mm +SMD 8x-dip-switch SPST Copal_CHS-08B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CVS-08xB_W5.9mm_P1mm +SMD 8x-dip-switch SPST Copal_CVS-08xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +20 +17 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_KingTek_DSHP08TJ_W5.25mm_P1.27mm_JPin +SMD 8x-dip-switch SPST KingTek_DSHP08TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_KingTek_DSHP08TS_W7.62mm_P1.27mm +SMD 8x-dip-switch SPST KingTek_DSHP08TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Omron_A6H-8101_W6.15mm_P1.27mm +SMD 8x-dip-switch SPST Omron_A6H-8101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Omron_A6S-810x_W8.9mm_P2.54mm +SMD 8x-dip-switch SPST Omron_A6S-810x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 9x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W8.61mm_P2.54mm_LowProfile +SMD 9x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_9.78x25.04mm_W8.61mm_P2.54mm +SMD 9x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x25.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_KingTek_DSHP09TJ_W5.25mm_P1.27mm_JPin +SMD 9x-dip-switch SPST KingTek_DSHP09TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_KingTek_DSHP09TS_W7.62mm_P1.27mm +SMD 9x-dip-switch SPST KingTek_DSHP09TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_Omron_A6S-910x_W8.9mm_P2.54mm +SMD 9x-dip-switch SPST Omron_A6S-910x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 10x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W8.61mm_P2.54mm_LowProfile +SMD 10x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_9.78x27.58mm_W8.61mm_P2.54mm +SMD 10x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x27.58mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Copal_CHS-10A_W5.08mm_P1.27mm_JPin +SMD 10x-dip-switch SPST Copal_CHS-10A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Copal_CHS-10B_W7.62mm_P1.27mm +SMD 10x-dip-switch SPST Copal_CHS-10B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_KingTek_DSHP10TJ_W5.25mm_P1.27mm_JPin +SMD 10x-dip-switch SPST KingTek_DSHP10TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_KingTek_DSHP10TS_W7.62mm_P1.27mm +SMD 10x-dip-switch SPST KingTek_DSHP10TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Omron_A6H-10101_W6.15mm_P1.27mm +SMD 10x-dip-switch SPST Omron_A6H-10101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Omron_A6S-1010x_W8.9mm_P2.54mm +SMD 10x-dip-switch SPST Omron_A6S-1010x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 11x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W8.61mm_P2.54mm_LowProfile +SMD 11x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_9.78x30.12mm_W8.61mm_P2.54mm +SMD 11x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x30.12mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 12x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +24 +24 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W8.61mm_P2.54mm_LowProfile +SMD 12x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +24 +24 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_9.78x32.66mm_W8.61mm_P2.54mm +SMD 12x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x32.66mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +24 +24 +Button_Switch_SMD +SW_DPDT_CK_JS202011JCQN +Sub-miniature slide switch, vertical, SMT J bend https://dznh3ojzb2azq.cloudfront.net/products/Slide/JS/documents/datasheet.pdf +switch DPDT SMT +0 +6 +6 +Button_Switch_SMD +SW_MEC_5GSH9 +MEC 5G single pole normally-open tactile switch +switch normally-open pushbutton push-button +0 +4 +4 +Button_Switch_SMD +SW_Push_1P1T-MP_NO_Horizontal_Alps_SKRTLAE010 +Side push button (https://www.alps.com/prod/info/E/PDF/Tact/SurfaceMount/SKRT/SKRT.pdf) +push horizontal SPST 1P1T +0 +5 +3 +Button_Switch_SMD +SW_Push_1P1T-SH_NO_CK_KMR2xxG +CK components KMR2 tactile switch with ground pin http://www.ckswitches.com/media/1479/kmr2.pdf +tactile switch kmr2 +0 +5 +3 +Button_Switch_SMD +SW_Push_1P1T_NO_6x6mm_H9.5mm +tactile push button, 6x6mm e.g. PTS645xx series, height=9.5mm +tact sw push 6mm smd +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KMR2 +CK components KMR2 tactile switch http://www.ckswitches.com/media/1479/kmr2.pdf +tactile switch kmr2 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KSC6xxJ +CK components KSC6 tactile switch https://www.ckswitches.com/media/1972/ksc6.pdf +tactile switch ksc6 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KSC7xxJ +CK components KSC7 tactile switch https://www.ckswitches.com/media/1973/ksc7.pdf +tactile switch ksc7 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_PTS125Sx43PSMTR +C&K Switches 1P1T SMD PTS125 Series 12mm Tact Switch with Pegs, https://www.ckswitches.com/media/1462/pts125.pdf +Button Tactile Switch SPST 1P1T +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_Vertical_Wuerth_434133025816 +https://katalog.we-online.com/em/datasheet/434133025816.pdf +tactile switch Wurth Wuerth +0 +4 +2 +Button_Switch_SMD +SW_Push_SPST_NO_Alps_SKRK +http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKRK/SKRKAHE020.html +SMD SMT button +0 +2 +2 +Button_Switch_SMD +SW_SP3T_PCM13 +Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf + +0 +8 +4 +Button_Switch_SMD +SW_SPDT_CK-JS102011SAQN +Sub-miniature slide switch, right-angle, http://www.ckswitches.com/media/1422/js.pdf +switch spdt +0 +3 +3 +Button_Switch_SMD +SW_SPDT_PCM12 +Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf + +0 +7 +3 +Button_Switch_SMD +SW_SPST_B3S-1000 +Surface Mount Tactile Switch for High-Density Packaging +Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3S-1100 +Surface Mount Tactile Switch for High-Density Packaging with Ground Terminal +Tactile Switch +0 +5 +3 +Button_Switch_SMD +SW_SPST_B3SL-1002P +Middle Stroke Tactile Switch, B3SL +Middle Stroke Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3SL-1022P +Middle Stroke Tactile Switch, B3SL +Middle Stroke Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3U-1000P +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, without Ground Terminal, without Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-1000P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, without Ground Terminal, with Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-1100P +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, with Ground Terminal, without Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-1100P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, with Ground Terminal, with Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-3000P +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, without Ground Terminal, without Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-3000P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, without Ground Terminal, with Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-3100P +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, with Ground Terminal, without Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-3100P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, with Ground Terminal, with Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_CK_KXT3 +https://www.ckswitches.com/media/1465/kxt3.pdf +Switch SPST KXT3 +0 +2 +2 +Button_Switch_SMD +SW_SPST_CK_RS282G05A3 +https://www.mouser.com/ds/2/60/RS-282G05A-SM_RT-1159762.pdf +SPST button tactile switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_EVPBF +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP0 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE28.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP2 +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP7A +Light Touch Switch,https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE20.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP7C +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQPE1 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE7.pdf + +0 +2 +2 +Button_Switch_SMD +SW_SPST_EVQQ2 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE28.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_FSMSM +http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=1437566-3&DocType=Customer+Drawing&DocLang=English +SPST button tactile switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_Omron_B3FS-100xP +Surface Mount Tactile Switch for High-Density Mounting, 3.1mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +4 +Button_Switch_SMD +SW_SPST_Omron_B3FS-101xP +Surface Mount Tactile Switch for High-Density Mounting, 4.3mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +4 +Button_Switch_SMD +SW_SPST_Omron_B3FS-105xP +Surface Mount Tactile Switch for High-Density Mounting, 7.3mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +4 +Button_Switch_SMD +SW_SPST_PTS645 +C&K Components SPST SMD PTS645 Series 6mm Tact Switch +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_PTS810 +C&K Components, PTS 810 Series, Microminiature SMT Top Actuated, http://www.ckswitches.com/media/1476/pts810.pdf +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_Panasonic_EVQPL_3PL_5PL_PT_A08 +Light Touch Switch, http://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE3.pdf +SMD SMT SPST EVQPL EVQPT +0 +6 +3 +Button_Switch_SMD +SW_SPST_Panasonic_EVQPL_3PL_5PL_PT_A15 +Light Touch Switch, http://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE3.pdf +SMD SMT SPST EVQPL EVQPT +0 +6 +3 +Button_Switch_SMD +SW_SPST_REED_CT05-XXXX-G1 +Coto Technologies SPST Reed Switch CT05-XXXX-G1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT05-XXXX-J1 +Coto Technologies SPST Reed Switch CT05-XXXX-J1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G1 +Coto Technologies SPST Reed Switch CT10-XXXX-G1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G2 +Coto Technologies SPST Reed Switch CT10-XXXX-G2 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G4 +Coto Technologies SPST Reed Switch CT10-XXXX-G4 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_SKQG_WithStem +ALPS 5.2mm Square Low-profile Type (Surface Mount) SKQG Series, With stem, http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKQG/SKQGAFE010.html +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_SKQG_WithoutStem +ALPS 5.2mm Square Low-profile Type (Surface Mount) SKQG Series, Without stem, http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKQG/SKQGAEE010.html +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305A +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305B +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305C +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3342 +Low-profile SMD Tactile Switch, https://www.e-switch.com/system/asset/product_line/data_sheet/165/TL3342.pdf +SPST Tactile Switch +0 +4 +2 +Button_Switch_THT +KSA_Tactile_SPST +KSA http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SWITCH SMD KSA SW +0 +5 +5 +Button_Switch_THT +Nidec_Copal_SH-7010C +4-bit rotary coded switch, through-hole, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_THT +Push_E-Switch_KS01Q01 +E-Switch KS01Q01 http://spec_sheets.e-switch.com/specs/29-KS01Q01.pdf +Push Button +0 +4 +4 +Button_Switch_THT +SW_CW_GPTS203211B +SPST Off-On Pushbutton, 1A, 30V, CW Industries P/N GPTS203211B, http://switches-connectors-custom.cwind.com/Asset/GPTS203211BR2.pdf +SPST button switch Off-On +0 +2 +2 +Button_Switch_THT +SW_CuK_JS202011AQN_DPDT_Angled +CuK sub miniature slide switch, JS series, DPDT, right angle, http://www.ckswitches.com/media/1422/js.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_CuK_JS202011CQN_DPDT_Straight +CuK sub miniature slide switch, JS series, DPDT, right angle, http://www.ckswitches.com/media/1422/js.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_CuK_OS102011MA1QN1_SPDT_Angled +CuK miniature slide switch, OS series, SPDT, right angle, http://www.ckswitches.com/media/1428/os.pdf +switch SPDT +0 +5 +3 +Button_Switch_THT +SW_DIP_SPSTx01_Piano_10.8x4.1mm_W7.62mm_P2.54mm +1x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x4.1mm +DIP Switch SPST Piano 7.62mm 300mil +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W7.62mm_P2.54mm_LowProfile +1x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx01_Slide_9.78x4.72mm_W7.62mm_P2.54mm +1x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x4.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx02_Piano_10.8x6.64mm_W7.62mm_P2.54mm +2x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x6.64mm +DIP Switch SPST Piano 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Piano_CTS_Series194-2MSTN_W7.62mm_P2.54mm +2x-dip-switch SPST CTS_Series194-2MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W7.62mm_P2.54mm_LowProfile +2x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Slide_9.78x7.26mm_W7.62mm_P2.54mm +2x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x7.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx03_Piano_10.8x9.18mm_W7.62mm_P2.54mm +3x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x9.18mm +DIP Switch SPST Piano 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Piano_CTS_Series194-3MSTN_W7.62mm_P2.54mm +3x-dip-switch SPST CTS_Series194-3MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W7.62mm_P2.54mm_LowProfile +3x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Slide_9.78x9.8mm_W7.62mm_P2.54mm +3x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x9.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx04_Piano_10.8x11.72mm_W7.62mm_P2.54mm +4x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x11.72mm +DIP Switch SPST Piano 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Piano_CTS_Series194-4MSTN_W7.62mm_P2.54mm +4x-dip-switch SPST CTS_Series194-4MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W7.62mm_P2.54mm_LowProfile +4x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Slide_9.78x12.34mm_W7.62mm_P2.54mm +4x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x12.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx05_Piano_10.8x14.26mm_W7.62mm_P2.54mm +5x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x14.26mm +DIP Switch SPST Piano 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Piano_CTS_Series194-5MSTN_W7.62mm_P2.54mm +5x-dip-switch SPST CTS_Series194-5MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W7.62mm_P2.54mm_LowProfile +5x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Slide_9.78x14.88mm_W7.62mm_P2.54mm +5x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x14.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx06_Piano_10.8x16.8mm_W7.62mm_P2.54mm +6x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x16.8mm +DIP Switch SPST Piano 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Piano_CTS_Series194-6MSTN_W7.62mm_P2.54mm +6x-dip-switch SPST CTS_Series194-6MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W7.62mm_P2.54mm_LowProfile +6x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Slide_9.78x17.42mm_W7.62mm_P2.54mm +6x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x17.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx07_Piano_10.8x19.34mm_W7.62mm_P2.54mm +7x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x19.34mm +DIP Switch SPST Piano 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Piano_CTS_Series194-7MSTN_W7.62mm_P2.54mm +7x-dip-switch SPST CTS_Series194-7MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W7.62mm_P2.54mm_LowProfile +7x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Slide_9.78x19.96mm_W7.62mm_P2.54mm +7x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x19.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx08_Piano_10.8x21.88mm_W7.62mm_P2.54mm +8x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x21.88mm +DIP Switch SPST Piano 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Piano_CTS_Series194-8MSTN_W7.62mm_P2.54mm +8x-dip-switch SPST CTS_Series194-8MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W7.62mm_P2.54mm_LowProfile +8x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Slide_9.78x22.5mm_W7.62mm_P2.54mm +8x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x22.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx09_Piano_10.8x24.42mm_W7.62mm_P2.54mm +9x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x24.42mm +DIP Switch SPST Piano 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Piano_CTS_Series194-9MSTN_W7.62mm_P2.54mm +9x-dip-switch SPST CTS_Series194-9MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W7.62mm_P2.54mm_LowProfile +9x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Slide_9.78x25.04mm_W7.62mm_P2.54mm +9x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x25.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx10_Piano_10.8x26.96mm_W7.62mm_P2.54mm +10x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x26.96mm +DIP Switch SPST Piano 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Piano_CTS_Series194-10MSTN_W7.62mm_P2.54mm +10x-dip-switch SPST CTS_Series194-10MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W7.62mm_P2.54mm_LowProfile +10x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Slide_9.78x27.58mm_W7.62mm_P2.54mm +10x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x27.58mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx11_Piano_10.8x29.5mm_W7.62mm_P2.54mm +11x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x29.5mm +DIP Switch SPST Piano 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Piano_CTS_Series194-11MSTN_W7.62mm_P2.54mm +11x-dip-switch SPST CTS_Series194-11MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W7.62mm_P2.54mm_LowProfile +11x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Slide_9.78x30.12mm_W7.62mm_P2.54mm +11x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x30.12mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx12_Piano_10.8x32.04mm_W7.62mm_P2.54mm +12x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x32.04mm +DIP Switch SPST Piano 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Piano_CTS_Series194-12MSTN_W7.62mm_P2.54mm +12x-dip-switch SPST CTS_Series194-12MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W7.62mm_P2.54mm_LowProfile +12x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Slide_9.78x32.66mm_W7.62mm_P2.54mm +12x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x32.66mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_E-Switch_EG1224_SPDT_Angled +E-Switch slide switch, EG series, SPDT, right angle, http://spec_sheets.e-switch.com/specs/P040042.pdf +switch SPDT +0 +7 +3 +Button_Switch_THT +SW_E-Switch_EG1271_DPDT +E-Switch sub miniature slide switch, EG series, DPDT, http://spec_sheets.e-switch.com/specs/P040047.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_E-Switch_EG2219_DPDT_Angled +E-Switch slide switch, EG series, DPDT, right angle, http://spec_sheets.e-switch.com/specs/P040170.pdf +switch DPDT +0 +10 +6 +Button_Switch_THT +SW_Lever_1P2T_NKK_GW12LxH +Switch, single pole double throw, right angle, http://www.nkkswitches.com/pdf/GW.pdf +switch single-pole double-throw spdt ON-ON horizontal +0 +5 +3 +Button_Switch_THT +SW_MEC_5GTH9 +MEC 5G single pole normally-open tactile switch https://cdn.sos.sk/productdata/80/f6/aabf7be6/5gth9358222.pdf +switch normally-open pushbutton push-button +0 +4 +2 +Button_Switch_THT +SW_NKK_BB15AH +https://www.nkkswitches.com/pdf/Bpushbuttons-1.pdf +Pushbutton Right-angle +0 +5 +3 +Button_Switch_THT +SW_NKK_G1xJP +Switch NKK G1xJP http://www.nkkswitches.com/pdf/gwillum.pdf +SWITCH TOGGLE ILLUM SPDT NKK +0 +6 +6 +Button_Switch_THT +SW_NKK_GW12LJP +Switch, single pole double throw, illuminated paddle, http://www.nkkswitches.com/pdf/gwillum.pdf +switch single-pole double-throw spdt ON-ON illuminated LED +0 +6 +6 +Button_Switch_THT +SW_PUSH-12mm +SW PUSH 12mm https://www.e-switch.com/system/asset/product_line/data_sheet/143/TL1100.pdf +tact sw push 12mm +0 +4 +2 +Button_Switch_THT +SW_PUSH-12mm_Wuerth-430476085716 +SW PUSH 12mm http://katalog.we-online.de/em/datasheet/430476085716.pdf +tact sw push 12mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm +https://www.omron.com/ecb/products/pdf/en-b3f.pdf +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H4.3mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=4.3mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H7.3mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=7.3mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H8.5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=8.5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H8mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=8mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H9.5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=9.5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H13mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=13mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_E-Switch_FS5700DP_DPDT +FS5700 series pushbutton footswitch, DPDT, https://www.e-switch.com/system/asset/product_line/data_sheet/226/FS5700.pdf +switch DPDT footswitch +0 +6 +6 +Button_Switch_THT +SW_PUSH_LCD_E3_SAxxxx +Switch with LCD screen E3 SAxxxx +switch normally-open pushbutton push-button LCD +0 +6 +6 +Button_Switch_THT +SW_PUSH_LCD_E3_SAxxxx_SocketPins +Switch with LCD screen E3 SAxxxx +switch normally-open pushbutton push-button LCD +0 +6 +6 +Button_Switch_THT +SW_Push_1P1T_NO_LED_E-Switch_TL1250 +illuminated right angle tact switch https://www.e-switch.com/system/asset/product_line/data_sheet/148/TL1250.pdf +led push switch right angle +0 +6 +4 +Button_Switch_THT +SW_Push_1P2T_Vertical_E-Switch_800UDP8P1A1M6 + right angle SPDT push button https://www.e-switch.com/system/asset/product_line/data_sheet/210/800U.pdf +IP67 ultra-miniture horizontal +0 +5 +3 +Button_Switch_THT +SW_Push_2P2T_Vertical_E-Switch_800UDP8P1A1M6 + right angle DPDT push button https://www.e-switch.com/system/asset/product_line/data_sheet/210/800U.pdf +IP67 ultra-miniture horizontal +0 +8 +6 +Button_Switch_THT +SW_Slide_1P2T_CK_OS102011MS2Q +CuK miniature slide switch, OS series, SPDT, https://www.ckswitches.com/media/1428/os.pdf +switch SPDT +0 +5 +3 +Button_Switch_THT +SW_TH_Tactile_Omron_B3F-10xx +SW_TH_Tactile_Omron_B3F-10xx_https://www.omron.com/ecb/products/pdf/en-b3f.pdf +Omron B3F-10xx +0 +4 +4 +Button_Switch_THT +SW_Tactile_SKHH_Angled +tactile switch 6mm ALPS SKHH right angle http://www.alps.com/prod/info/E/HTML/Tact/SnapIn/SKHH/SKHHLUA010.html +tactile switch 6mm ALPS SKHH right angle +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx31-2LFS +tactile switch SPST right angle, PTS645VL31-2 LFS +tactile switch SPST angled PTS645VL31-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx39-2LFS +tactile switch SPST right angle, PTS645VL39-2 LFS +tactile switch SPST angled PTS645VL39-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx58-2LFS +tactile switch SPST right angle, PTS645VL58-2 LFS +tactile switch SPST angled PTS645VL58-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx83-2LFS +tactile switch SPST right angle, PTS645VL83-2 LFS +tactile switch SPST angled PTS645VL83-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_Straight_KSA0Axx1LFTR +SW PUSH SMALL http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SW PUSH SMALL Tactile C&K +0 +4 +2 +Button_Switch_THT +SW_Tactile_Straight_KSL0Axx1LFTR +SW PUSH SMALL http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SW PUSH SMALL Tactile C&K +0 +4 +2 +Buzzer_Beeper +Buzzer_12x9.5RM7.6 +Generic Buzzer, D12mm height 9.5mm with RM7.6mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_15x7.5RM7.6 +Generic Buzzer, D15mm height 7.5mm with RM7.6mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_CUI_CPT-9019S-SMT +https://www.cui.com/product/resource/cpt-9019s-smt.pdf +buzzer piezo +0 +2 +2 +Buzzer_Beeper +Buzzer_D14mm_H7mm_P10mm +Generic Buzzer, D14mm height 7mm with pitch 10mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_Mallory_AST1109MLTRQ +Mallory low-profile piezo buzzer, https://www.mspindy.com/specifications/AST1109MLTRQ.pdf +buzzer piezo +0 +2 +2 +Buzzer_Beeper +Buzzer_Murata_PKMCS0909E4000-R1 +Murata Buzzer http://www.murata.com/en-us/api/pdfdownloadapi?cate=&partno=PKMCS0909E4000-R1 +Murata Buzzer Beeper +0 +2 +2 +Buzzer_Beeper +Buzzer_TDK_PS1240P02BT_D12.2mm_H6.5mm +Buzzer, D12.2mm height 6.5mm, https://product.tdk.com/info/en/catalog/datasheets/piezoelectronic_buzzer_ps_en.pdf +buzzer +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_CUI_CMT-8504-100-SMT +magnetic transducer buzzer, 5V, SPL of 100 dB at 10 cm, https://www.cuidevices.com/product/resource/pdf/cmt-8504-100-smt-tr.pdf +CMT 8504 +0 +4 +4 +Buzzer_Beeper +MagneticBuzzer_CUI_CST-931RP-A +CST-931RP-A, http://www.cui.com/product/resource/cst-931rp-a.pdf +CST-931RP-A +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_Kingstate_KCG0601 +Buzzer, Elektromagnetic Beeper, Summer, +Kingstate KCG0601 +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_Kobitone_254-EMB84Q-RO +MagneticBuzzer Kobitone 254-EMB84Q-RO https://www.mouser.es/datasheet/2/209/KT-400385-1171904.pdf +MagneticBuzzer Kobitone 254-EMB84Q-RO +0 +3 +3 +Buzzer_Beeper +MagneticBuzzer_PUI_AT-0927-TT-6-R +Buzzer Magnetic 9mm AT-0927-TT-6-R, http://www.puiaudio.com/pdf/AT-0927-TT-6-R.pdf +Buzzer Magnetic 9mm AT-0927-TT-6-R +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABI-009-RC +Buzzer, Elektromagnetic Beeper, Summer, 6V-DC, +Pro Signal ABI-009-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABI-010-RC +Buzzer, Elektromagnetic Beeper, Summer, 12V-DC, +Pro Signal ABI-010-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABT-410-RC +Buzzer, Elektromagnetic Beeper, Summer, 1,5V-DC, +Pro Signal ABT-410-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProjectsUnlimited_AI-4228-TWT-R +Buzzer, Elektromagnetic Beeper, Summer, 3-28V-DC, https://www.kynix.com/uploadfiles/pdf/AI-4228-TWT-R.pdf +Projects Unlimited AI-4228-TWT-R +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_StarMicronics_HMB-06_HMB-12 +Buzzer, Elektromagnetic Beeper, Summer, +Star Micronics HMB-06 HMB-12 +0 +2 +2 +Buzzer_Beeper +PUIAudio_SMT_0825_S_4_R +SMD 8540, http://www.puiaudio.com/product-detail.aspx?partnumber=SMT-0825-S-4-R +SMD 8540 +0 +4 +4 +Buzzer_Beeper +Speaker_CUI_CMR-1206S-67 +Speaker, 30mW, 300-7000Hz, IP67 face, 12x6x2,25mm, https://www.cuidevices.com/product/resource/cmr-12062s-67.pdf +speaker CUI +0 +2 +2 +Calibration_Scale +Gauge_10mm_Type1_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 1, +Gauge Massstab 10mm CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type1_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 1, +Gauge Massstab 10mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type2_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 2, +Gauge Massstab 10mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type2_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 2, +Gauge Massstab 10mm SilkScreenTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type3_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 3, +Gauge Massstab 10mm CopperTop Type 3 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type3_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 3, +Gauge Massstab 10mm SilkScreenTop Type 3 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type4_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 4, +Gauge Massstab 10mm CopperTop Type 4 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type4_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 4, +Gauge Massstab 10mm SilkScreenTop Type 4 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type5_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 5, +Gauge Massstab 10mm CopperTop Type 5 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type5_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 5, +Gauge Massstab 10mm SilkScreenTop Type 5 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type1_CopperTop +Gauge, Massstab, 50mm, CopperTop, Type 1, +Gauge Massstab 50mm CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type1_SilkScreenTop +Gauge, Massstab, 50mm, SilkScreenTop, Type 1, +Gauge Massstab 50mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type2_CopperTop +Gauge, Massstab, 50mm, CopperTop, Type 2, +Gauge Massstab 50mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type2_SilkScreenTop +Gauge, Massstab, 50mm, SilkScreenTop, Type 2, +Gauge Massstab 50mm SilkScreenTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Grid_Type1_CopperTop +Gauge, Massstab, 100mm, Gitter, Grid, CopperTop, Type 1, +Gauge Massstab 100mm Gitter Grid CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type1_CopperTop +Gauge, Massstab, 100mm, CopperTop, Type 1, +Gauge Massstab 100mm CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type1_SilkScreenTop +Gauge, Massstab, 100mm, SilkScreenTop, Type 1, +Gauge Massstab 100mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type2_CopperTop +Gauge, Massstab, 100mm, CopperTop, Type 2, +Gauge Massstab 100mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type2_SilkScreenTop +Gauge, Massstab, 100mm, SilkScreenTop, Type 2, +Gauge Massstab 100mm SilkScreenTop Type 2 +0 +0 +0 +Capacitor_SMD +CP_Elec_3x5.3 +SMT capacitor, aluminium electrolytic, 3x5.3, Cornell Dubilier Electronics +Capacitor Electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_3x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 3.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x3 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.3 +SMD capacitor, aluminum electrolytic, Vishay, 4.0x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.4 +SMD capacitor, aluminum electrolytic, Panasonic A5 / Nichicon, 4.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 4.0x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.8 +SMD capacitor, aluminum electrolytic, Panasonic, 4.0x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x3 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x3.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x4.4 +SMD capacitor, aluminum electrolytic, Panasonic B45, 5.0x4.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.3 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 5.0x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.8 +SMD capacitor, aluminum electrolytic, Panasonic, 5.0x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.9 +SMD capacitor, aluminum electrolytic, Panasonic B6, 5.0x5.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x3 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x3.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x4.9 +SMD capacitor, aluminum electrolytic, Panasonic C5, 6.3x4.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.2 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 6.3x5.2mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.3 +SMD capacitor, aluminum electrolytic, Cornell Dubilier, 6.3x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.4 +SMD capacitor, aluminum electrolytic, Panasonic C55, 6.3x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.4_Nichicon +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 6.3x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.8 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.9 +SMD capacitor, aluminum electrolytic, Panasonic C6, 6.3x5.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x7.7 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x7.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x9.9 +SMD capacitor, aluminum electrolytic, Panasonic C10, 6.3x9.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.2 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x6.2mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.5 +SMD capacitor, aluminum electrolytic, Rubycon, 8.0x6.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 8.0x6.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.9 +SMD capacitor, aluminum electrolytic, Panasonic E7, 8.0x6.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x10 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x10mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x10.5 +SMD capacitor, aluminum electrolytic, Vishay 0810, 8.0x10.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x11.9 +SMD capacitor, aluminum electrolytic, Panasonic E12, 8.0x11.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x7.7 +SMD capacitor, aluminum electrolytic, Nichicon, 10.0x7.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x7.9 +SMD capacitor, aluminum electrolytic, Panasonic F8, 10.0x7.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x10 +SMD capacitor, aluminum electrolytic, Nichicon, 10.0x10.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x10.5 +SMD capacitor, aluminum electrolytic, Vishay 1010, 10.0x10.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x12.5 +SMD capacitor, aluminum electrolytic, Vishay 1012, 10.0x12.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x12.6 +SMD capacitor, aluminum electrolytic, Panasonic F12, 10.0x12.6mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x14.3 +SMD capacitor, aluminum electrolytic, Vishay 1014, 10.0x14.3mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_16x17.5 +SMD capacitor, aluminum electrolytic, Vishay 1616, 16.0x17.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_16x22 +SMD capacitor, aluminum electrolytic, Vishay 1621, 16.0x22.0mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_18x17.5 +SMD capacitor, aluminum electrolytic, Vishay 1816, 18.0x17.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_18x22 +SMD capacitor, aluminum electrolytic, Vishay 1821, 18.0x22.0mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +C_0201_0603Metric +Capacitor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +capacitor +0 +4 +2 +Capacitor_SMD +C_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Capacitor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +4 +2 +Capacitor_SMD +C_0402_1005Metric +Capacitor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0402_1005Metric_Pad0.74x0.62mm_HandSolder +Capacitor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0504_1310Metric +Capacitor SMD 0504 (1310 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0504_1310Metric_Pad0.83x1.28mm_HandSolder +Capacitor SMD 0504 (1310 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0603_1608Metric +Capacitor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0603_1608Metric_Pad1.08x0.95mm_HandSolder +Capacitor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0805_2012Metric +Capacitor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf, https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0805_2012Metric_Pad1.18x1.45mm_HandSolder +Capacitor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf, https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_01005_0402Metric +Capacitor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +capacitor +0 +4 +2 +Capacitor_SMD +C_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Capacitor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +4 +2 +Capacitor_SMD +C_1206_3216Metric +Capacitor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1206_3216Metric_Pad1.33x1.80mm_HandSolder +Capacitor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1210_3225Metric +Capacitor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1210_3225Metric_Pad1.33x2.70mm_HandSolder +Capacitor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1812_4532Metric +Capacitor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1812_4532Metric_Pad1.57x3.40mm_HandSolder +Capacitor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1825_4564Metric +Capacitor SMD 1825 (4564 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1825_4564Metric_Pad1.57x6.80mm_HandSolder +Capacitor SMD 1825 (4564 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_2220_5650Metric +Capacitor SMD 2220 (5650 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_2220_5650Metric_Pad1.97x5.40mm_HandSolder +Capacitor SMD 2220 (5650 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_2225_5664Metric +Capacitor SMD 2225 (5664 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_2225_5664Metric_Pad1.80x6.60mm_HandSolder +Capacitor SMD 2225 (5664 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_3640_9110Metric +Capacitor SMD 3640 (9110 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_3640_9110Metric_Pad2.10x10.45mm_HandSolder +Capacitor SMD 3640 (9110 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_Elec_3x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 3.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_4x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 4.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_4x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 4.0x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_5x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 5.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_5x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 5.0x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x7.7 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x7.7mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x6.2 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x6.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x10.2 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x10.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_10x10.2 +SMD capacitor, aluminum electrolytic nonpolar, 10.0x10.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZB4-A +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZB4 TZB4-A +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZB4-B +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZB4 TZB4-A +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZC3 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZC3 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZR1 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZR1 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZW4 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZW4 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZY2 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZY2 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Sprague-Goodman_SGC3 +trimmer capacitor SMD horizontal, http://media.wix.com/ugd/d86717_38d9821e12823a7aa9cef38c6c2a73cc.pdf + Sprague Goodman SGC3 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JN +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JN +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JQ +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JQ +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JR +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JR +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JV +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JV +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JZ +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JR +0 +2 +2 +Capacitor_THT +CP_Axial_L10.0mm_D4.5mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=10*4.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 10mm diameter 4.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L10.0mm_D6.0mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=10*6mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 10mm diameter 6mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D5.0mm_P18.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=18mm, , length*diameter=11*5mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 18mm length 11mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D6.0mm_P18.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=18mm, , length*diameter=11*6mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 18mm length 11mm diameter 6mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D8.0mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=11*8mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 11mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D6.5mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*6.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 6.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D8.0mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*8mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D10.0mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L20.0mm_D10.0mm_P26.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=26mm, , length*diameter=20*10mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 26mm length 20mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L20.0mm_D13.0mm_P26.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=26mm, , length*diameter=20*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 26mm length 20mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L21.0mm_D8.0mm_P28.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=28mm, , length*diameter=21*8mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 28mm length 21mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L25.0mm_D10.0mm_P30.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=30mm, , length*diameter=25*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 30mm length 25mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L26.5mm_D20.0mm_P33.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=33mm, , length*diameter=26.5*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 33mm length 26.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D10.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*10mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D13.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D16.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*16mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D20.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D10.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D12.5mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*12.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D15.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*15mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 15mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D18.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*18mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L34.5mm_D20.0mm_P41.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=41mm, , length*diameter=34.5*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 41mm length 34.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D13.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D16.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*16mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D20.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L38.0mm_D18.0mm_P44.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=44mm, , length*diameter=38*18mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 44mm length 38mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L38.0mm_D21.0mm_P44.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=44mm, , length*diameter=38*21mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 44mm length 38mm diameter 21mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L40.0mm_D16.0mm_P48.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=48mm, , length*diameter=40*16mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 48mm length 40mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D23.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D26.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D29.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D32.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D35.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.5mm_D20.0mm_P49.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=49mm, , length*diameter=42.5*20mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 49mm length 42.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L46.0mm_D20.0mm_P52.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=52mm, , length*diameter=46*20mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 52mm length 46mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D23.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D26.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D29.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D32.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D35.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D23.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D26.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D29.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D32.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D35.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D23.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D26.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D29.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D32.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D35.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D23.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D26.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D29.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D32.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D35.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D4.0mm_P1.50mm +CP, Radial series, Radial, pin pitch=1.50mm, , diameter=4mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 1.50mm diameter 4mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D4.0mm_P2.00mm +CP, Radial series, Radial, pin pitch=2.00mm, , diameter=4mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.00mm diameter 4mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D5.0mm_P2.00mm +CP, Radial series, Radial, pin pitch=2.00mm, , diameter=5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.00mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D5.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D6.3mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=6.3mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 6.3mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D7.5mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=7.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 7.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P3.50mm +CP, Radial series, Radial, pin pitch=3.50mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.50mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P3.80mm +CP, Radial series, Radial, pin pitch=3.80mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.80mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P2.50mm_P5.00mm +CP, Radial series, Radial, pin pitch=2.50mm 5.00mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm 5.00mm diameter 10mm Electrolytic Capacitor +0 +4 +2 +Capacitor_THT +CP_Radial_D10.0mm_P3.50mm +CP, Radial series, Radial, pin pitch=3.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P3.80mm +CP, Radial series, Radial, pin pitch=3.80mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.80mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P5.00mm_P7.50mm +CP, Radial series, Radial, pin pitch=5.00mm 7.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm 7.50mm diameter 10mm Electrolytic Capacitor +0 +4 +2 +Capacitor_THT +CP_Radial_D10.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D14.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=14mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 14mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D14.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=14mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 14mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D16.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=16mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D17.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=17mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 17mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D18.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=18mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D22.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=22mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 22mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D22.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=22mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 22mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D24.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=24mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 24mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D24.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=24mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 24mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D25.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=25mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 25mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D25.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=25mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 25mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D26.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=26mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 26mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D26.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=26mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D30.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=30mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 30mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D30.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=30mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 30mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D35.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=35mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 35mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D35.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=35mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 35mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D40.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=40mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 40mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D40.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=40mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 40mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D4.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=4.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 4.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D4.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=4.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 4.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=5.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 5.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=5.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 5.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=5.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 5.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=5.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 5.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D6.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=6.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 6.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D6.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=6.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 6.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D7.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=7.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 7.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D7.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=7.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 7.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D8.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=8.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 8.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D8.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=8.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 8.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D9.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=9.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 9.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D9.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=9.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 9.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D10.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=10.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 10.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D10.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=10.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 10.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P7.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=7.5mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 7.5mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P10.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=10mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 10mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P12.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=12.5mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 12.5mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 15mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P7.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=7.5mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 7.5mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P10.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=10mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 10mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P12.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=12.5mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 12.5mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 15mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D6.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D6.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D7.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D7.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D8.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*8.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 8.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D8.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*8.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 8.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D9.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D9.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D10.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D10.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D6.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=17*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 17mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D6.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=17*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 17mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D7.0mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=17*7.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 17mm diameter 7.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D7.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=17*7.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 17mm diameter 7.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D7.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D8.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*8.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 8.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D9.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*9mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 9mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D9.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L22.0mm_D9.5mm_P27.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=27.5mm, , length*diameter=22*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 27.5mm length 22mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L22.0mm_D10.5mm_P27.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=27.5mm, , length*diameter=22*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 27.5mm length 22mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Disc_D3.0mm_W1.6mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.0*1.6mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.0mm width 1.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.0mm_W2.0mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3*2mm^2, Capacitor +C Disc series Radial pin pitch 2.50mm diameter 3mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.4mm_W2.1mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.4*2.1mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.4mm width 2.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.8mm_W2.6mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.8*2.6mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.8mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D4.3mm_W1.9mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=4.3*1.9mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 4.3mm width 1.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D4.7mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=4.7*2.5mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 4.7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.0mm_W2.5mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=5*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 2.50mm diameter 5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=5*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.1mm_W3.2mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=5.1*3.2mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 5.1mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D6.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=6*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 6mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D6.0mm_W4.4mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=6*4.4mm^2, Capacitor +C Disc series Radial pin pitch 5.00mm diameter 6mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*2.5mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W4.4mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*4.4mm^2, Capacitor +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=8*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 8mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=9*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 9mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=10*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 10mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.0mm_W4.4mm_P7.75mm +C, Disc series, Radial, pin pitch=7.75mm, , diameter*width=12*4.4mm^2, Capacitor +C Disc series Radial pin pitch 7.75mm diameter 12mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=12.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 12.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=12.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 12.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D14.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=14.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 14.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D14.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=14.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 14.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D16.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=16.0*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 16.0mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D16.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=16.0*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 16.0mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D4.0mm_H5.0mm_P1.50mm +C, Radial series, Radial, pin pitch=1.50mm, diameter=4mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 1.50mm diameter 4mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D4.0mm_H7.0mm_P1.50mm +C, Radial series, Radial, pin pitch=1.50mm, diameter=4mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 1.50mm diameter 4mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H5.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H7.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H11.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=11mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 11mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H5.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H7.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H11.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=11mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 11mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D8.0mm_H7.0mm_P3.50mm +C, Radial series, Radial, pin pitch=3.50mm, diameter=8mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 3.50mm diameter 8mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D8.0mm_H11.5mm_P3.50mm +C, Radial series, Radial, pin pitch=3.50mm, diameter=8mm, height=11.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 3.50mm diameter 8mm height 11.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H12.5mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=12.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 12.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H16.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=16mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 16mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H20.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=20mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 20mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D12.5mm_H20.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=12.5mm, height=20mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 12.5mm height 20mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D12.5mm_H25.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=12.5mm, height=25mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 12.5mm height 25mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D16.0mm_H25.0mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=16mm, height=25mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 16mm height 25mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D16.0mm_H31.5mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=16mm, height=31.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 16mm height 31.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D18.0mm_H35.5mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=18mm, height=35.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 18mm height 35.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.0mm_W2.5mm_P2.50mm +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4*2.5mm^2, Capacitor +C Rect series Radial pin pitch 2.50mm length 4mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W2.0mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*2mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W3.0mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*3.0mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W3.8mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*3.8mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 3.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W4.6mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*4.6mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 4.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W5.5mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*5.5mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 5.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W2.0mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*2mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W2.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*2.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W3.5mm_P2.50mm_P5.00mm +C, Rect series, Radial, pin pitch=2.50mm 5.00mm, , length*width=7*3.5mm^2, Capacitor +C Rect series Radial pin pitch 2.50mm 5.00mm length 7mm width 3.5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L7.0mm_W3.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*3.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W4.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*4.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W6.0mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*6mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W6.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*6.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 6.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W2.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*2.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W3.0mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*3.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W3.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*3.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W4.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*4.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W5.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*5.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 5.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W7.2mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*7.2mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 7.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W8.5mm_P5.00mm_FKP2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*8.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W11.0mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.5mm_W6.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.5*6.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7.5mm width 6.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.6mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.2mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.3mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.4mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.6mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.8mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.9mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.0mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.2mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.9mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W5.1mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W5.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*5.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 5.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W6.4mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W6.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*6.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 6.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W7.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*7.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 7.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W8.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*8.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W9.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*9.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 9.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W9.8mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*9.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 9.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W2.5mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*2.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W3.0mm_P7.50mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*3mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W3.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*3.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W4.0mm_P7.50mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W4.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*4.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W5.0mm_P5.00mm_P7.50mm +C, Rect series, Radial, pin pitch=5.00mm 7.50mm, , length*width=10*5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm 7.50mm length 10mm width 5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L10.3mm_W4.5mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*4.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W5.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W5.7mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*5.7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 5.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W7.2mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*7.2mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 7.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W2.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*2.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 2.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W3.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*3.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 3.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W3.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*3.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W4.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*4.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 4.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W4.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*4.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 4.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W5.1mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W5.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*5.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 5.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W6.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*6.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 6.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W6.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W7.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W8.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*8.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 8.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.1mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.9mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W8.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*8.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 8.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W8.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*8.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 8.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W9.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*9.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 9.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W9.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*9.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 9.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W3.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*3mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W4.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W5.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W6.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W6.5mm_P7.50mm_P10.00mm +C, Rect series, Radial, pin pitch=7.50mm 10.00mm, , length*width=13*6.5mm^2, Capacitor +C Rect series Radial pin pitch 7.50mm 10.00mm length 13mm width 6.5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L13.0mm_W8.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.5mm_W4.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13.5*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13.5mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.5mm_W5.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13.5*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W4.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*4.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 4.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W4.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*4.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 4.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W5.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W6.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W7.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W7.3mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W8.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*8.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 8.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W8.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*8.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 8.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W9.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W9.2mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*9.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 9.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W10.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*10.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 10.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W10.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*10.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 10.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W11.2mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*11.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 11.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W11.8mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*11.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 11.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.5mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W5.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W6.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W7.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W8.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W9.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W11.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W5.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W6.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W7.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W8.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W9.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W11.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W7.0mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W8.3mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*8.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 8.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W8.6mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*8.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 8.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.1mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.3mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.9mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.2mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.6mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.8mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W5.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W6.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W7.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W8.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*8.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W10.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*10.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 10.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W11.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*11.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 11.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W9.0mm_P22.00mm +C, Rect series, Radial, pin pitch=22.00mm, , length*width=27*9mm^2, Capacitor +C Rect series Radial pin pitch 22.00mm length 27mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W9.0mm_P23.00mm +C, Rect series, Radial, pin pitch=23.00mm, , length*width=27*9mm^2, Capacitor +C Rect series Radial pin pitch 23.00mm length 27mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W11.0mm_P22.00mm +C, Rect series, Radial, pin pitch=22.00mm, , length*width=27*11mm^2, Capacitor +C Rect series Radial pin pitch 22.00mm length 27mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W8.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W10.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*10mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 10mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W12.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*12mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 12mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.6mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.8mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.9mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W9.1mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*9.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 9.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W9.6mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*9.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 9.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W11.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*11mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W11.9mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*11.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 11.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W12.2mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*12.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 12.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W13.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*13mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W13.8mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*13.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 13.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W14.2mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*14.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 14.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W16.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*16mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 16mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W9.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W11.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W13.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W15.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W17.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*17mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 17mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W20.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L32.0mm_W15.0mm_P27.00mm +C, Rect series, Radial, pin pitch=27.00mm, , length*width=32*15mm^2, Capacitor +C Rect series Radial pin pitch 27.00mm length 32mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W13.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W15.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W20.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W9.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W11.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W13.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W15.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W17.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*17mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 17mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W19.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*19mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 19mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W20.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W24.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*24mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 24mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W31.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*31mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 31mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W35.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*35mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 35mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W40.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*40mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 40mm Capacitor +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-08_AVX-J +Tantalum Capacitor SMD AVX-J (1608-08 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-08_AVX-J_Pad1.25x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-J (1608-08 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-10_AVX-L +Tantalum Capacitor SMD AVX-L (1608-10 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-10_AVX-L_Pad1.25x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-L (1608-10 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-12_Kemet-R +Tantalum Capacitor SMD Kemet-R (2012-12 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-12_Kemet-R_Pad1.30x1.05mm_HandSolder +Tantalum Capacitor SMD Kemet-R (2012-12 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-15_AVX-P +Tantalum Capacitor SMD AVX-P (2012-15 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-15_AVX-P_Pad1.30x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-P (2012-15 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-10_Kemet-I +Tantalum Capacitor SMD Kemet-I (3216-10 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-10_Kemet-I_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-I (3216-10 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-12_Kemet-S +Tantalum Capacitor SMD Kemet-S (3216-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-12_Kemet-S_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-S (3216-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-18_Kemet-A +Tantalum Capacitor SMD Kemet-A (3216-18 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-18_Kemet-A_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-A (3216-18 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-12_Kemet-T +Tantalum Capacitor SMD Kemet-T (3528-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-12_Kemet-T_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-T (3528-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-15_AVX-H +Tantalum Capacitor SMD AVX-H (3528-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-15_AVX-H_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD AVX-H (3528-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-21_Kemet-B +Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-21_Kemet-B_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-15_Kemet-U +Tantalum Capacitor SMD Kemet-U (6032-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-15_Kemet-U_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-U (6032-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-20_AVX-F +Tantalum Capacitor SMD AVX-F (6032-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-20_AVX-F_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD AVX-F (6032-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-28_Kemet-C +Tantalum Capacitor SMD Kemet-C (6032-28 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-28_Kemet-C_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-C (6032-28 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-20_AVX-U +Tantalum Capacitor SMD AVX-U (7132-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-20_AVX-U_Pad2.72x3.50mm_HandSolder +Tantalum Capacitor SMD AVX-U (7132-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-28_AVX-C +Tantalum Capacitor SMD AVX-C (7132-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-28_AVX-C_Pad2.72x3.50mm_HandSolder +Tantalum Capacitor SMD AVX-C (7132-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-15_AVX-R +Tantalum Capacitor SMD AVX-R (7260-15 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-15_AVX-R_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-R (7260-15 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-20_AVX-M +Tantalum Capacitor SMD AVX-M (7260-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-20_AVX-M_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-M (7260-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-28_AVX-M +Tantalum Capacitor SMD AVX-M (7260-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-28_AVX-M_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-M (7260-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-38_AVX-R +Tantalum Capacitor SMD AVX-R (7260-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-38_AVX-R_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-R (7260-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-15_Kemet-W +Tantalum Capacitor SMD Kemet-W (7343-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-15_Kemet-W_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-W (7343-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-20_Kemet-V +Tantalum Capacitor SMD Kemet-V (7343-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-20_Kemet-V_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-V (7343-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-30_AVX-N +Tantalum Capacitor SMD AVX-N (7343-30 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-30_AVX-N_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD AVX-N (7343-30 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-31_Kemet-D +Tantalum Capacitor SMD Kemet-D (7343-31 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-31_Kemet-D_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-D (7343-31 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-40_Kemet-Y +Tantalum Capacitor SMD Kemet-Y (7343-40 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-40_Kemet-Y_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-Y (7343-40 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-43_Kemet-X +Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-43_Kemet-X_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7360-38_Kemet-E +Tantalum Capacitor SMD Kemet-E (7360-38 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7360-38_Kemet-E_Pad2.25x4.25mm_HandSolder +Tantalum Capacitor SMD Kemet-E (7360-38 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-38_AVX-V +Tantalum Capacitor SMD AVX-V (7361-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-38_AVX-V_Pad2.18x3.30mm_HandSolder +Tantalum Capacitor SMD AVX-V (7361-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-438_AVX-U +Tantalum Capacitor SMD AVX-U (7361-438 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-438_AVX-U_Pad2.18x3.30mm_HandSolder +Tantalum Capacitor SMD AVX-U (7361-438 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Connector +Banana_Jack_1Pin +Single banana socket, footprint - 6mm drill +banana socket +0 +1 +1 +Connector +Banana_Jack_2Pin +Dual banana socket, footprint - 2 x 6mm drills +banana socket +0 +2 +2 +Connector +Banana_Jack_3Pin +Triple banana socket, footprint - 3 x 6mm drills +banana socket +0 +3 +3 +Connector +CUI_PD-30 +3 pin connector, PD-30, http://www.cui.com/product/resource/pd-30.pdf +connector 3-pin PD-30 power DIN +0 +4 +4 +Connector +CalTest_CT3151 +Right-angle standard banana jack, http://www.caltestelectronics.com/images/attachments/P315100rH_drawing.pdf +banana jack horizontal +0 +4 +1 +Connector +Connector_SFP_and_Cage +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=2227302&DocType=Customer+Drawing&DocLang=English +SFP+ SFP +0 +40 +21 +Connector +DTF13-12Px +http://www.te.com/usa-en/product-DTF13-12PA-G003.html +DEUTSCH DT header 12 pin +0 +12 +12 +Connector +FanPinHeader_1x03_P2.54mm_Vertical +3-pin CPU fan Through hole pin header, see http://www.formfactors.org/developer%5Cspecs%5Crev1_2_public.pdf +pin header 3-pin CPU fan +0 +3 +3 +Connector +FanPinHeader_1x04_P2.54mm_Vertical +4-pin CPU fan Through hole pin header, e.g. for Wieson part number 2366C888-007 Molex 47053-1000, Foxconn HF27040-M1, Tyco 1470947-1 or equivalent, see http://www.formfactors.org/developer%5Cspecs%5Crev1_2_public.pdf +pin header 4-pin CPU fan +0 +4 +4 +Connector +GB042-34S-H10 +http://www.lsmtron.com/pdf/Connector&Antenna_catalog.PDF +34pin SMD connector +0 +34 +34 +Connector +IHI_B6A-PCB-45_Vertical +https://lugsdirect.com/PDF_Webprint/B6A-PCB-45-XX(-X).pdf +connector IHI B6A-PCB-45 +0 +49 +1 +Connector +JWT_A3963_1x02_P3.96mm_Vertical +JWT A3963, 3.96mm pitch Pin head connector (http://www.jwt.com.tw/pro_pdf/A3963.pdf) +connector JWT A3963 pinhead +0 +2 +2 +Connector +NS-Tech_Grove_1x04_P2mm_Vertical +https://statics3.seeedstudio.com/images/opl/datasheet/3470130P1.pdf +Grove-1x04 +0 +4 +4 +Connector +SpringContact_Harwin_S1941-46R +7.25mm SMT Multi-directional Spring Contact (T+R), https://cdn.harwin.com/pdfs/S1941R.pdf +spring contact emi emc shield +0 +1 +1 +Connector +Tag-Connect_TC2030-IDC-FP_2x03_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2030-IDC.pdf +tag connect programming header pogo pins +0 +6 +6 +Connector +Tag-Connect_TC2030-IDC-NL_2x03_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2030-IDC-NL.pdf +tag connect programming header pogo pins +0 +6 +6 +Connector +Tag-Connect_TC2050-IDC-FP_2x05_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2050-IDC-430%20Datasheet.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2050-IDC-NL_2x05_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2050-IDC-NL%20Datasheet.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2050-IDC-NL_2x05_P1.27mm_Vertical_with_bottom_clip +Tag-Connect programming header with bottom courtyard for TC2050-NL Clip board ; https://www.tag-connect.com/wp-content/uploads/bsk-pdf-manager/TC2050-IDC-NL_Datasheet_8.pdf https://www.tag-connect.com/wp-content/uploads/bsk-pdf-manager/TC2050-CLIP_Datasheet_25.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2070-IDC-FP_2x07_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2070-IDC%20Datasheet.pdf +tag connect programming header pogo pins +0 +14 +14 +Connector_AMASS +AMASS_MR30PW-FB_1x03_P3.50mm_Horizontal +Connector XT30 Horizontal PCB Female, https://www.tme.eu/en/Document/5e47640ba39fa492dbd4c0f4c8ae7b93/MR30PW%20SPEC.pdf +RC Connector XT30 +0 +5 +3 +Connector_AMASS +AMASS_MR30PW-M_1x03_P3.50mm_Horizontal +Connector XT30 Horizontal PCB Male, https://www.tme.eu/en/Document/5e47640ba39fa492dbd4c0f4c8ae7b93/MR30PW%20SPEC.pdf +RC Connector XT30 +0 +5 +3 +Connector_AMASS +AMASS_XT30PW-F_1x02_P2.50mm_Horizontal +Connector XT30 Horizontal PCB Female, https://www.tme.eu/en/Document/ce4077e36b79046da520ca73227e15de/XT30PW%20SPEC.pdf +RC Connector XT30 +0 +4 +2 +Connector_AMASS +AMASS_XT30PW-M_1x02_P2.50mm_Horizontal +Connector XT30 Horizontal PCB Male, https://www.tme.eu/en/Document/ce4077e36b79046da520ca73227e15de/XT30PW%20SPEC.pdf +RC Connector XT30 +0 +4 +2 +Connector_AMASS +AMASS_XT30U-F_1x02_P5.0mm_Vertical +Connector XT30 Vertical Cable Female, https://www.tme.eu/en/Document/3cbfa5cfa544d79584972dd5234a409e/XT30U%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30U-M_1x02_P5.0mm_Vertical +Connector XT30 Vertical Cable Male, https://www.tme.eu/en/Document/3cbfa5cfa544d79584972dd5234a409e/XT30U%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30UPB-F_1x02_P5.0mm_Vertical +Connector XT30 Vertical PCB Female, https://www.tme.eu/en/Document/4acc913878197f8c2e30d4b8cdc47230/XT30UPB%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30UPB-M_1x02_P5.0mm_Vertical +Connector XT30 Vertical PCB Male, https://www.tme.eu/en/Document/4acc913878197f8c2e30d4b8cdc47230/XT30UPB%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT60-F_1x02_P7.20mm_Vertical +AMASS female XT60, through hole, vertical, https://www.tme.eu/Document/2d152ced3b7a446066e6c419d84bb460/XT60%20SPEC.pdf +XT60 female vertical +0 +2 +2 +Connector_AMASS +AMASS_XT60-M_1x02_P7.20mm_Vertical +AMASS female XT60, through hole, vertical, https://www.tme.eu/Document/2d152ced3b7a446066e6c419d84bb460/XT60%20SPEC.pdf +XT60 female vertical +0 +2 +2 +Connector_Amphenol +Amphenol_M8S-03PMMR-SF8001 +M8 Male connector for panel, 90° PCB mount (https://www.amphenolltw.com/2012download/2D%20PDF/03_M%20Series%20Sensor%20Connectors/M8S-XXPMMR-SF8001.pdf) +three-pin M8 +0 +5 +4 +Connector_Audio +Jack_3.5mm_CUI_SJ-3523-SMT_Horizontal +3.5 mm, Stereo, Right Angle, Surface Mount (SMT), Audio Jack Connector (https://www.cui.com/product/resource/sj-352x-smt-series.pdf) +3.5mm audio cui horizontal jack stereo +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ-3524-SMT_Horizontal +3.5 mm, Stereo, Right Angle, Surface Mount (SMT), Audio Jack Connector (https://www.cui.com/product/resource/sj-352x-smt-series.pdf) +3.5mm audio cui horizontal jack stereo +0 +4 +4 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3533NG_Horizontal +TRS 3.5mm, horizontal, through-hole, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3533NG_Horizontal_CircularHoles +TRS 3.5mm, horizontal, through-hole, , circular holeshttps://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal circular +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3535NG_Horizontal +TRS 3.5mm, horizontal, through-hole, with switch, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal +0 +5 +5 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3535NG_Horizontal_CircularHoles +TRS 3.5mm, horizontal, through-hole, with switch, circular holes, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal circular +0 +5 +5 +Connector_Audio +Jack_3.5mm_Ledino_KB3SPRS_Horizontal +https://www.reichelt.de/index.html?ACTION=7&LA=3&OPEN=0&INDEX=0&FILENAME=C160%252FKB3SPRS.pdf +jack stereo TRS +0 +5 +5 +Connector_Audio +Jack_3.5mm_PJ311_Horizontal +PJ311 6pin SMD 3.5mm stereo headphones jack. +headphones jack plug stereo 3.5mm PJ311 +0 +6 +6 +Connector_Audio +Jack_3.5mm_PJ320D_Horizontal +Headphones with microphone connector, 3.5mm, 4 pins (http://www.qingpu-electronics.com/en/products/WQP-PJ320D-72.html) +3.5mm jack mic microphone phones headphones 4pins audio plug +0 +4 +4 +Connector_Audio +Jack_3.5mm_PJ320E_Horizontal +Headphones with microphone connector, 3.5mm, 4 pins (http://www.qingpu-electronics.com/en/products/WQP-PJ320E-177.html) +3.5mm jack mic microphone phones headphones 4pins audio plug +0 +5 +4 +Connector_Audio +Jack_3.5mm_PJ31060-I_Horizontal +PJ31060-I 6pin SMD 3.5mm headphones jack (http://www.china-bsun.com/Product48/1577.html) +headphones jack plug stereo 3.5mm PJ31060-I PJ31060 +0 +6 +6 +Connector_Audio +Jack_3.5mm_QingPu_WQP-PJ398SM_Vertical_CircularHoles +TRS 3.5mm, vertical, Thonkiconn, PCB mount, (http://www.qingpu-electronics.com/en/products/WQP-PJ398SM-362.html) +WQP-PJ398SM WQP-PJ301M-12 TRS 3.5mm mono vertical jack thonkiconn qingpu +0 +3 +3 +Connector_Audio +Jack_3.5mm_Switronic_ST-005-G_horizontal +3.5mm horizontal headphones jack, http://akizukidenshi.com/download/ds/switronic/ST-005-G.pdf +Connector Audio Switronic ST-005-G +0 +4 +3 +Connector_Audio +Jack_6.35mm_Neutrik_NJ2FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, Non-switching mono jack (T/S), https://www.neutrik.com/en/product/nj2fd-v +neutrik jack vertical +0 +2 +2 +Connector_Audio +Jack_6.35mm_Neutrik_NJ3FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, Non-switching stereo jack (T/R/S), https://www.neutrik.com/en/product/nj3fd-v +neutrik jack vertical +0 +3 +3 +Connector_Audio +Jack_6.35mm_Neutrik_NJ5FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, 2 x switching (normalling) stereo jack (T/TN/R/RN/S), https://www.neutrik.com/en/product/nj5fd-v +neutrik jack vertical +0 +5 +5 +Connector_Audio +Jack_6.35mm_Neutrik_NJ6FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, 3 x switching (normalling) stereo jack (T/TN/R/RN/S/SN), https://www.neutrik.com/en/product/nj6fd-v +neutrik jack vertical +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NJ6TB-V_Vertical +6.35mm (1/4 in) Vertical Jack, 3 x switching (normalling) stereo jack B-gauge type (T/TN/R/RN/S/SN), https://www.neutrik.com/en/product/nj6tb-v +neutrik jack vertical +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HCD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with chrome ferrule and straight PCB pins, https://www.neutrik.com/en/product/nmj4hcd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HFD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with full threaded nose and straight PCB pins, https://www.neutrik.com/en/product/nmj4hfd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HFD3_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with a full threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj4hfd3 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HHD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with a half threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj4hhd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HCD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with chrome ferrule and straight PCB pins, https://www.neutrik.com/en/product/nmj6hcd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HCD3_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with chrome ferrule and offset PCB pins, https://www.neutrik.com/en/product/nmj6hcd3 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD2-AU_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, full threaded nose, straight PCB pins, gold plated contacts, https://www.neutrik.com/en/product/nmj6hfd2-au +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and straight PCB pins, https://www.neutrik.com/en/product/nmj6hfd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD3_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj6hfd3 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD4_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and fishtail PCB pins, https://www.neutrik.com/en/product/nmj6hfd4 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HHD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with half threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj6hhd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ3HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, unswitched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj3hf-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj4hf-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HF_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, fully threaded nose, https://www.neutrik.com/en/product/nrj4hf +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HH-1_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, half threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj4hh-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HH_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, half threaded nose, https://www.neutrik.com/en/product/nrj4hh +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-1-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hf-1-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hf-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, fully threaded nose, https://www.neutrik.com/en/product/nrj6hf-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, fully threaded nose, https://www.neutrik.com/en/product/nrj6hf +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, half threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hh-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, half threaded nose, https://www.neutrik.com/en/product/nrj6hh-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, half threaded nose, https://www.neutrik.com/en/product/nrj6hh +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose, gold plated contacts, efficient chassis ground connection, T+R+S normalling contact, https://www.neutrik.com/en/product/nrj6hm-1-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1-PRE_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose, efficient chassis ground connection, T+R normalling contact, https://www.neutrik.com/en/product/nrj6hm-1-pre +neutrik jack slim +0 +6 +5 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose with efficient chassis ground connection, T+R+S normalling contact, https://www.neutrik.com/en/product/nrj6hm-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ8HC_Horizontal +Stacking Jacks, Mono dual jack, full nose, https://www.neutrik.com/en/product/nsj8hc +neutrik jack stacking +0 +9 +9 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ8HL_Horizontal +Stacking Jacks, Mono dual jack, quick fix nose, https://www.neutrik.com/en/product/nsj8hl +neutrik jack stacking +0 +9 +9 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HC_Horizontal +Stacking Jacks, Stereo dual jack, full nose, https://www.neutrik.com/en/product/nsj12hc +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HF-1_Horizontal +Stacking Jacks, Stereo dual jack, full threaded nose, https://www.neutrik.com/en/product/nsj12hf-1 +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HH-1_Horizontal +Stacking Jacks, Stereo dual jack, half threaded nose, https://www.neutrik.com/en/product/nsj12hh-1 +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HL_Horizontal +Stacking Jacks, Stereo dual jack, quick fix nose, https://www.neutrik.com/en/product/nsj12hl +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj5fi-h-0 +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj5fi-h +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj5fi-v-0 +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj5fi-v +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H-0_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fa-h-0 +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H-DA_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/ncj6fa-h-da +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, https://www.neutrik.com/en/product/ncj6fa-h +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V-0_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fa-v-0 +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V-DA_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/ncj6fa-v-da +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, https://www.neutrik.com/en/product/ncj6fa-v +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj6fi-h-0 +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fi-h +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj6fi-v-0 +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fi-v +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, horizontal PCB mount, https://www.neutrik.com/en/product/ncj9fi-h-0 +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj9fi-h +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, vertical PCB mount, https://www.neutrik.com/en/product/ncj9fi-v-0 +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj9fi-v +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj10fi-h-0 +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj10fi-h +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj10fi-v-0 +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj10fi-v +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah1-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1-DA_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3faah1-da +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH2-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah2-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH2_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah2 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV-0_Vertical +AA Series, 3 pole female receptacle, grounding: without ground/shell contact, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1-0_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav1-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1-DA_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3faav1-da +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV2-0_Vertical +AA Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav2-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV2_Vertical +AA Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav2 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV_Vertical +AA Series, 3 pole female receptacle, grounding: without ground/shell contact, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1-DA_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fah1-da +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2-DA_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fah2-da +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, lateral left PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3fahl1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3fahr1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR2-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR2_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3fahr2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1-DA_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fav1-da +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2-DA_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fav2-da +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV_Vertical +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-B_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbh1-b +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-DA_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbh1-da +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-E_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3fbh1-e +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fbh1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-B_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbh2-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-DA_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbh2-da +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-E_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3fbh2-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fbh2 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBHL1_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3fbhl1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-0_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring, no latch, https://www.neutrik.com/en/product/nc3fbv1-0 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-B_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbv1-b +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-DA_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbv1-da +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-B_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbv2-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-DA_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbv2-da +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-SW_Vertical +B Series, 3 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv2-sw +neutrik xlr b +0 +7 +7 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv2 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH-0_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH-1_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah-1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV-0_Vertical +AA Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV-1_Vertical +AA Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav-1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV_Vertical +AA Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAFH-PH_Horizontal +A Series, Chassis connector H female (A series layout), horizontal PCB mount, https://www.neutrik.com/en/product/nc4mafh-ph +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAH-0_Horizontal +A Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mah-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAHL_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3mahl +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAHR_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3mahr +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAH_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mah +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAMH-PH_Horizontal +A Series, Chassis connector Phoenix H male (A series layout), horizontal PCB mount, https://www.neutrik.com/en/product/nc4mamh-ph +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAV-0_Vertical +A Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, vertical PCB mount, https://www.neutrik.com/en/product/nc3mav-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAV_Vertical +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3mav +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-0_Horizontal +B Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh-0 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-1_Horizontal +B Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh-1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbh-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-E_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3mbh-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHL-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral left PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbhl-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHL_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral left PCB mount, https://www.neutrik.com/en/product/nc3mbhl +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHR-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral right PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbhr-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHR_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral right PCB mount, https://www.neutrik.com/en/product/nc3mbhr +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-0_Vertical +B Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-0 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-1_Vertical +B Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-B_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbv-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-E_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3mbv-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-SW_Vertical +B Series, 3 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-sw +neutrik xlr b +0 +7 +7 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC4FAH-0_Horizontal +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc4fah-0 +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAH_Horizontal +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4fah +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAV-0_Vertical +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc4fav-0 +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAV_Vertical +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4fav +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FBH_Horizontal +B Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4fbh +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FBV_Vertical +B Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4fbv +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MAH_Horizontal +A Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4mah +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MAV_Vertical +A Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4mav +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MBH_Horizontal +B Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4mbh +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MBV_Vertical +B Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4mbv +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH-0_Horizontal +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc5fah-0 +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH-DA_Horizontal +A Series, 5 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc5fah-da +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH_Horizontal +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5fah +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV-DA_Vertical +A Series, 5 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc5fav-da +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV-SW_Vertical +A Series, 5 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, color coding possible, https://www.neutrik.com/en/product/nc5fav-sw +neutrik xlr a +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV_Vertical +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fav +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBH-B_Horizontal +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5fbh-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBH_Horizontal +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5fbh +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV-B_Vertical +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5fbv-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV-SW_Vertical +B Series, 5 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fbv-sw +neutrik xlr b +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV_Vertical +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fbv +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MAH_Horizontal +A Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5mah +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MAV-SW_Vertical +A Series, 5 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mav-sw +neutrik xlr a +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5MAV_Vertical +A Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mav +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBH-B_Horizontal +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5mbh-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBH_Horizontal +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5mbh +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV-B_Vertical +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5mbv-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV-SW_Vertical +B Series, 5 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mbv-sw +neutrik xlr b +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV_Vertical +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mbv +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_speakON-6.35mm_Neutrik_NLJ2MD-H_Horizontal +speakON Combo, 2 pole combination of speakON socket and 6.35mm (1/4in) jack receptacle, horizontal pcb mount, https://www.neutrik.com/en/product/nlj2md-h +neutrik speakon combo +0 +2 +2 +Connector_Audio +Jack_speakON-6.35mm_Neutrik_NLJ2MD-V_Vertical +speakON Combo, 2 pole combination of speakON socket and 6.35mm (1/4in) jack receptacle, vertical pcb mount, https://www.neutrik.com/en/product/nlj2md-v +neutrik speakon combo +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL2MD-H_Horizontal +speakON Chassis Connectors, 2 pole chassis connector, gray D-size flange, countersunk thru holes, horizontal PCB, https://www.neutrik.com/en/product/nl2md-h +neutrik speakon +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL2MD-V_Vertical +speakON Chassis Connectors, 2 pole chassis connector, black D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl2md-v +neutrik speakon +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-1_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, countersunk thru holes, horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-1 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-2_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, mirrored self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-2 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-3_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-3 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, grey D-size flange, self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-1_Vertical +speakON Chassis Connectors, 4 pole chassis connector, grey D-size flange, self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-1 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-2_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, mirrored self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-2 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-R_Vertical +speakON Chassis Connectors, 4 pole chassis connector, red D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-r +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-S_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, switchable version of NL4MD-V with 8 vertical PCB contacts (4 switching contacts), https://www.neutrik.com/en/product/nl4md-v-s +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL8MD-V-1_Vertical +speakON Chassis Connectors, 8 pole chassis connector, nickel metal square G-size flange, self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl8md-v-1 +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NL8MD-V_Vertical +speakON Chassis Connectors, 8 pole chassis connector, nickel metal square G-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl8md-v +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NLT4MD-V_Vertical +STX Series, 4 pole male chassis connector, metal housing, vertical PCB mount, self tapping screw holes (A-screw), https://www.neutrik.com/en/product/nlt4md-v +neutrik speakon stx +0 +4 +4 +Connector_Audio +MiniXLR-5_Switchcraft_TRAPC_Horizontal +http://www.switchcraft.com/ProductSummary.aspx?Parent=620 http://www.switchcraft.com/Drawings/TRAPC_X-TRASM_X_SERIES_CD.PDF +THT Mini XLR 5Pin right angle +0 +5 +5 +Connector_BarrelJack +BarrelJack_CLIFF_FC681465S_SMT_Horizontal +Surface-mount DC Barrel Jack, https://www.cliffuk.co.uk/products/dcconnectors/FC681465S.pdf +Power Jack SMT +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-036AH-SMT_Horizontal +Surface-mount DC Barrel Jack, http://www.cui.com/product/resource/pj-036ah-smt.pdf +Power Jack SMT +0 +3 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-063AH_Horizontal +Barrel Jack, 2.0mm ID, 5.5mm OD, 24V, 8A, no switch, https://www.cui.com/product/resource/pj-063ah.pdf +barrel jack cui dc power +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-063AH_Horizontal_CircularHoles +Barrel Jack, 2.0mm ID, 5.5mm OD, 24V, 8A, no switch, https://www.cui.com/product/resource/pj-063ah.pdf +barrel jack cui dc power +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-102AH_Horizontal +Thin-pin DC Barrel Jack, https://cdn-shop.adafruit.com/datasheets/21mmdcjackDatasheet.pdf +Power Jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_Horizontal +DC Barrel Jack +Power Jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_Wuerth_6941xx301002 +Wuerth electronics barrel jack connector (5.5mm outher diameter, inner diameter 2.05mm or 2.55mm depending on exact order number), See: http://katalog.we-online.de/em/datasheet/6941xx301002.pdf +connector barrel jack +0 +3 +3 +Connector_Card +CF-Card_3M_N7E50-7516PK-20-WF +Compact Flash Card connector (https://multimedia.3m.com/mws/media/22365O/3mtm-cf-card-header-compactflashtm-type-i-sm-ts0662.pdf) +connector cf +0 +54 +50 +Connector_Card +SD_Kyocera_145638009211859+ +SD Card Connector, Normal Type, Outer Tail, Without Ejector (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638009511859+ +SD Card Connector, Normal Type, Outer Tail, Spring Eject Type (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638109211859+ +SD Card Connector, Reverse Type, Outer Tail, Without Ejector (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638109511859+ +SD Card Connector, Reverse Type, Outer Tail, Spring Eject Type (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_TE_2041021 +SD card connector, top mount, SMT (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F2041021%7FB%7Fpdf%7FEnglish%7FENG_CD_2041021_B_C_2041021_B.pdf%7F2041021-4) +sd card +0 +15 +12 +Connector_Card +microSD_HC_Hirose_DM3AT-SF-PEJM5 +Micro SD, SMD, right-angle, push-pull (https://www.hirose.com/product/en/download_file/key_name/DM3AT-SF-PEJM5/category/Drawing%20(2D)/doc_file_id/44099/?file_category_id=6&item_id=06090031000&is_series=) +Micro SD +0 +14 +11 +Connector_Card +microSD_HC_Hirose_DM3BT-DSF-PEJS +Micro SD, SMD, reverse on-board, right-angle, push-pull (https://www.hirose.com/product/en/download_file/key_name/DM3BT-DSF-PEJS/category/Drawing%20(2D)/doc_file_id/44097/?file_category_id=6&item_id=06090029900&is_series=) +Micro SD +0 +16 +11 +Connector_Card +microSD_HC_Hirose_DM3D-SF +Micro SD, SMD, right-angle, push-pull (https://media.digikey.com/PDF/Data%20Sheets/Hirose%20PDFs/DM3D-SF.pdf) +Micro SD +0 +14 +11 +Connector_Card +microSD_HC_Molex_104031-0811 +1.10mm Pitch microSD Memory Card Connector, Surface Mount, Push-Pull Type, 1.42mm Height, with Detect Switch (https://www.molex.com/pdm_docs/sd/1040310811_sd.pdf) +microSD SD molex +0 +14 +11 +Connector_Card +microSD_HC_Wuerth_693072010801 +http://katalog.we-online.de/em/datasheet/693072010801.pdf +Micro SD Wuerth Wurth Würth +0 +12 +9 +Connector_Card +microSIM_JAE_SF53S006VCBR2000 +https://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ115712.pdf +microSIM GSM Card +0 +14 +7 +Connector_Coaxial +BNC_Amphenol_031-6575_Horizontal +dual independently isolated BNC plug (https://www.amphenolrf.com/downloads/dl/file/id/2980/product/644/031_6575_customer_drawing.pdf) +Dual BNC Amphenol Horizontal +0 +6 +4 +Connector_Coaxial +BNC_Amphenol_B6252HB-NPP3G-50_Horizontal +http://www.farnell.com/datasheets/612848.pdf +BNC Amphenol Horizontal +0 +4 +2 +Connector_Coaxial +BNC_PanelMountable_Vertical +Panel-mountable BNC connector mounted through PCB, vertical +BNC connector +0 +2 +2 +Connector_Coaxial +BNC_TEConnectivity_1478204_Vertical +BNC female PCB mount 4 pin straight chassis connector http://www.te.com/usa-en/product-1-1478204-0.html +BNC female PCB mount 4 pin straight chassis connector +0 +5 +2 +Connector_Coaxial +BNC_Win_364A2x95_Horizontal +Dual front isolated BNC plug (https://www.winconn.com/wp-content/uploads/364A2595.pdf) +Dual BNC Horizontal Isolated +0 +6 +3 +Connector_Coaxial +CoaxialSwitch_Hirose_MS-156C3_Horizontal +Subminiature Coaxial Switch 1.35mm High, DC to 11GHz +Switch Coaxial RF +0 +12 +3 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_0.8mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_1.0mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_1.6mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-1471_Vertical +http://www.molex.com/pdm_docs/sd/734151471_sd.pdf +Molex MMCX Coaxial Connector 50 ohms Female Jack Vertical THT +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_901-144_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/7023/product/3103/901_144_customer_drawing.pdf +SMA THT Female Jack Vertical +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-10_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/4007/product/2974/132134_10_customer_drawing.pdf +SMA SMD Female Jack Vertical +0 +3 +2 +Connector_Coaxial +SMA_Amphenol_132134-11_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/3406/product/2975/132134_11_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-14_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1793/product/2976/132134_14_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-16_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1141/product/2978/132134_16_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/2187/product/2843/132134_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132203-12_Horizontal +https://www.amphenolrf.com/media/downloads/1769/132203-12.pdf +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132289_EdgeMount +http://www.amphenolrf.com/132289.html +SMA +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132291-12_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1688/product/3020/132291_12_customer_drawing.pdf +SMA THT Female Jack Vertical Bulkhead +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132291_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/3222/product/2918/132291_customer_drawing.pdf +SMA THT Female Jack Vertical Bulkhead +0 +5 +2 +Connector_Coaxial +SMA_Molex_73251-1153_EdgeMount_Horizontal +Molex SMA RF Connectors, Edge Mount, (http://www.molex.com/pdm_docs/sd/732511150_sd.pdf) +sma edge +0 +11 +2 +Connector_Coaxial +SMA_Molex_73251-2120_EdgeMount_Horizontal +Molex SMA RF Connector, Edge Mount, (http://www.molex.com/pdm_docs/sd/732512120_sd.pdf) +sma edge +0 +11 +2 +Connector_Coaxial +SMA_Molex_73251-2200_Horizontal +https://www.molex.com/webdocs/datasheets/pdf/en-us/0732512200_RF_COAX_CONNECTORS.pdf +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Samtec_SMA-J-P-X-ST-EM1_EdgeMount +Connector SMA, 0Hz to 20GHz, 50Ohm, Edge Mount (http://suddendocs.samtec.com/prints/sma-j-p-x-st-em1-mkt.pdf) +SMA Straight Samtec Edge Mount +0 +5 +2 +Connector_Coaxial +SMA_Wurth_60312002114503_Vertical +https://www.we-online.de/katalog/datasheet/60312002114503.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMB_Jack_Vertical +SMB pcb mounting jack +SMB Jack Striaght +0 +5 +2 +Connector_Coaxial +U.FL_Hirose_U.FL-R-SMT-1_Vertical +Hirose U.FL Coaxial https://www.hirose.com/product/en/products/U.FL/U.FL-R-SMT-1%2810%29/ +Hirose U.FL Coaxial +0 +3 +2 +Connector_Coaxial +U.FL_Molex_MCRF_73412-0110_Vertical +Molex Microcoaxial RF Connectors (MCRF), mates Hirose U.FL, (http://www.molex.com/pdm_docs/sd/734120110_sd.pdf) +mcrf hirose ufl u.fl microcoaxial +0 +4 +2 +Connector_DIN +DIN41612_B2_2x8_Female_Vertical_THT +DIN41612 connector, type B/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +16 +16 +Connector_DIN +DIN41612_B2_2x8_Male_Horizontal_THT +DIN41612 connector, type B/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +16 +16 +Connector_DIN +DIN41612_B2_2x16_Female_Vertical_THT +DIN41612 connector, type B/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +32 +32 +Connector_DIN +DIN41612_B2_2x16_Male_Horizontal_THT +DIN41612 connector, type B/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +32 +32 +Connector_DIN +DIN41612_B3_2x5_Female_Vertical_THT +DIN41612 connector, type B/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +10 +10 +Connector_DIN +DIN41612_B3_2x5_Male_Horizontal_THT +DIN41612 connector, type B/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +10 +10 +Connector_DIN +DIN41612_B3_2x10_Female_Vertical_THT +DIN41612 connector, type B/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +20 +20 +Connector_DIN +DIN41612_B3_2x10_Male_Horizontal_THT +DIN41612 connector, type B/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +20 +20 +Connector_DIN +DIN41612_B_1x32_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_1x32_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x16_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x16_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x32_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +64 +64 +Connector_DIN +DIN41612_B_2x32_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +64 +64 +Connector_DIN +DIN41612_C2_2x16_Female_Vertical_THT +DIN41612 connector, type C/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +32 +32 +Connector_DIN +DIN41612_C2_2x16_Male_Horizontal_THT +DIN41612 connector, type C/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +32 +32 +Connector_DIN +DIN41612_C2_3x16_Female_Vertical_THT +DIN41612 connector, type C/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +48 +48 +Connector_DIN +DIN41612_C2_3x16_Male_Horizontal_THT +DIN41612 connector, type C/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +48 +48 +Connector_DIN +DIN41612_C3_2x10_Female_Vertical_THT +DIN41612 connector, type C/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +20 +20 +Connector_DIN +DIN41612_C3_2x10_Male_Horizontal_THT +DIN41612 connector, type C/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +20 +20 +Connector_DIN +DIN41612_C3_3x10_Female_Vertical_THT +DIN41612 connector, type C/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +30 +30 +Connector_DIN +DIN41612_C3_3x10_Male_Horizontal_THT +DIN41612 connector, type C/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +30 +30 +Connector_DIN +DIN41612_C_1x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_1x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x16_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x16_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +64 +64 +Connector_DIN +DIN41612_C_2x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +64 +64 +Connector_DIN +DIN41612_C_3x16_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +48 +48 +Connector_DIN +DIN41612_C_3x16_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +48 +48 +Connector_DIN +DIN41612_C_3x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +96 +96 +Connector_DIN +DIN41612_C_3x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +96 +96 +Connector_DIN +DIN41612_D_2x8_Female_Vertical_THT +DIN41612 connector, type D, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +16 +16 +Connector_DIN +DIN41612_D_2x8_Male_Horizontal_THT +DIN41612 connector, type D, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +16 +16 +Connector_DIN +DIN41612_D_2x16_Female_Vertical_THT +DIN41612 connector, type D, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +32 +32 +Connector_DIN +DIN41612_D_2x16_Male_Horizontal_THT +DIN41612 connector, type D, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_RowsAC_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_RowsAC_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_3x16_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +48 +48 +Connector_DIN +DIN41612_E_3x16_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +48 +48 +Connector_DIN +DIN41612_F_2x16_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_RowsZD_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_RowsZD_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_3x16_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +48 +48 +Connector_DIN +DIN41612_F_3x16_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +48 +48 +Connector_DIN +DIN41612_Q2_2x16_Male_Horizontal_THT +DIN41612 connector, type Q/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/2 +0 +32 +32 +Connector_DIN +DIN41612_Q2_2x16_Male_Vertical_THT +DIN41612 connector, type Q/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/2 +0 +32 +32 +Connector_DIN +DIN41612_Q3_2x10_Male_Horizontal_THT +DIN41612 connector, type Q/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/3 +0 +20 +20 +Connector_DIN +DIN41612_Q3_2x10_Male_Vertical_THT +DIN41612 connector, type Q/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/3 +0 +20 +20 +Connector_DIN +DIN41612_Q_2x32_Male_Horizontal_THT +DIN41612 connector, type Q, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q +0 +64 +64 +Connector_DIN +DIN41612_Q_2x32_Male_Vertical_THT +DIN41612 connector, type Q, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q +0 +64 +64 +Connector_DIN +DIN41612_R2_2x16_Male_Horizontal_THT +DIN41612 connector, type R/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +32 +32 +Connector_DIN +DIN41612_R2_2x16_Male_Vertical_THT +DIN41612 connector, type R/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +32 +32 +Connector_DIN +DIN41612_R2_3x16_Male_Horizontal_THT +DIN41612 connector, type R/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +48 +48 +Connector_DIN +DIN41612_R2_3x16_Male_Vertical_THT +DIN41612 connector, type R/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +48 +48 +Connector_DIN +DIN41612_R3_2x10_Male_Horizontal_THT +DIN41612 connector, type R/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +20 +20 +Connector_DIN +DIN41612_R3_2x10_Male_Vertical_THT +DIN41612 connector, type R/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +20 +20 +Connector_DIN +DIN41612_R3_3x10_Male_Horizontal_THT +DIN41612 connector, type R/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +30 +30 +Connector_DIN +DIN41612_R3_3x10_Male_Vertical_THT +DIN41612 connector, type R/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +30 +30 +Connector_DIN +DIN41612_R_1x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_1x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x16_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x16_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +64 +64 +Connector_DIN +DIN41612_R_2x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +64 +64 +Connector_DIN +DIN41612_R_3x16_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +48 +48 +Connector_DIN +DIN41612_R_3x16_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +48 +48 +Connector_DIN +DIN41612_R_3x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +96 +96 +Connector_DIN +DIN41612_R_3x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +96 +96 +Connector_Dsub +DSUB-9_Female_EdgeMount_P2.77mm +9-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Vertical_P2.77x2.84mm +9-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Vertical_P2.77x2.84mm_MountingHoles +9-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_EdgeMount_P2.77mm +9-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Vertical_P2.77x2.84mm +9-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Vertical_P2.77x2.84mm_MountingHoles +9-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 25mm +0 +11 +10 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 25mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_EdgeMount_P2.77mm +15-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Vertical_P2.77x2.84mm +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Vertical_P2.77x2.84mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_EdgeMount_P2.77mm +15-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Vertical_P2.77x2.84mm +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Vertical_P2.77x2.84mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-25_Female_EdgeMount_P2.77mm +25-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Vertical_P2.77x2.84mm +25-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Vertical_P2.77x2.84mm_MountingHoles +25-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_EdgeMount_P2.77mm +25-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Vertical_P2.77x2.84mm +25-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Vertical_P2.77x2.84mm_MountingHoles +25-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +26-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +26-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-37_Female_EdgeMount_P2.77mm +37-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Vertical_P2.77x2.84mm +37-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Vertical_P2.77x2.84mm_MountingHoles +37-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_EdgeMount_P2.77mm +37-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Vertical_P2.77x2.84mm +37-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Vertical_P2.77x2.84mm_MountingHoles +37-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +44-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +44-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x2.54mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x2.54mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Female_Vertical_P2.41x1.98mm_MountingHoles +62-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.41x1.98mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector straight vertical THT female pitch 2.41x1.98mm mounting holes distance 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x2.54mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x2.54mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Male_Vertical_P2.41x1.98mm_MountingHoles +62-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.41x1.98mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector straight vertical THT male pitch 2.41x1.98mm mounting holes distance 63.5mm +0 +64 +63 +Connector_FFC-FPC +Hirose_FH12-6S-0.5SH_1x06-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-6S-0.5SH, 6 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +8 +7 +Connector_FFC-FPC +Hirose_FH12-8S-0.5SH_1x08-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-8S-0.5SH, 8 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +10 +9 +Connector_FFC-FPC +Hirose_FH12-10S-0.5SH_1x10-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-10S-0.5SH, 10 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +12 +11 +Connector_FFC-FPC +Hirose_FH12-11S-0.5SH_1x11-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-11S-0.5SH, 11 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +13 +12 +Connector_FFC-FPC +Hirose_FH12-12S-0.5SH_1x12-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-12S-0.5SH, 12 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +14 +13 +Connector_FFC-FPC +Hirose_FH12-13S-0.5SH_1x13-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-13S-0.5SH, 13 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +15 +14 +Connector_FFC-FPC +Hirose_FH12-14S-0.5SH_1x14-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-14S-0.5SH, 14 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +16 +15 +Connector_FFC-FPC +Hirose_FH12-15S-0.5SH_1x15-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-15S-0.5SH, 15 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +17 +16 +Connector_FFC-FPC +Hirose_FH12-16S-0.5SH_1x16-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-16S-0.5SH, 16 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +18 +17 +Connector_FFC-FPC +Hirose_FH12-17S-0.5SH_1x17-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-17S-0.5SH, 17 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +19 +18 +Connector_FFC-FPC +Hirose_FH12-18S-0.5SH_1x18-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-18S-0.5SH, 18 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +20 +19 +Connector_FFC-FPC +Hirose_FH12-19S-0.5SH_1x19-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-19S-0.5SH, 19 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +21 +20 +Connector_FFC-FPC +Hirose_FH12-20S-0.5SH_1x20-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-20S-0.5SH, 20 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +22 +21 +Connector_FFC-FPC +Hirose_FH12-22S-0.5SH_1x22-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-22S-0.5SH, 22 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +24 +23 +Connector_FFC-FPC +Hirose_FH12-24S-0.5SH_1x24-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-24S-0.5SH, 24 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +26 +25 +Connector_FFC-FPC +Hirose_FH12-25S-0.5SH_1x25-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-25S-0.5SH, 25 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +27 +26 +Connector_FFC-FPC +Hirose_FH12-26S-0.5SH_1x26-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-26S-0.5SH, 26 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +28 +27 +Connector_FFC-FPC +Hirose_FH12-28S-0.5SH_1x28-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-28S-0.5SH, 28 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +30 +29 +Connector_FFC-FPC +Hirose_FH12-30S-0.5SH_1x30-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-30S-0.5SH, 30 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +32 +31 +Connector_FFC-FPC +Hirose_FH12-32S-0.5SH_1x32-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-32S-0.5SH, 32 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +34 +33 +Connector_FFC-FPC +Hirose_FH12-33S-0.5SH_1x33-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-33S-0.5SH, 33 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +35 +34 +Connector_FFC-FPC +Hirose_FH12-34S-0.5SH_1x34-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-34S-0.5SH, 34 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +36 +35 +Connector_FFC-FPC +Hirose_FH12-35S-0.5SH_1x35-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-35S-0.5SH, 35 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +37 +36 +Connector_FFC-FPC +Hirose_FH12-36S-0.5SH_1x36-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-36S-0.5SH, 36 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +38 +37 +Connector_FFC-FPC +Hirose_FH12-40S-0.5SH_1x40-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-40S-0.5SH, 40 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +42 +41 +Connector_FFC-FPC +Hirose_FH12-45S-0.5SH_1x45-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-45S-0.5SH, 45 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +47 +46 +Connector_FFC-FPC +Hirose_FH12-50S-0.5SH_1x50-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-50S-0.5SH, 50 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +52 +51 +Connector_FFC-FPC +Hirose_FH12-53S-0.5SH_1x53-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-53S-0.5SH, 53 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +55 +54 +Connector_FFC-FPC +JAE_FF0825SA1_2Rows-25Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0825SA1, 25 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +25 +25 +Connector_FFC-FPC +JAE_FF0829SA1_2Rows-29Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0829SA1, 29 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +29 +29 +Connector_FFC-FPC +JAE_FF0841SA1_2Rows-41Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0841SA1, 41 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +41 +41 +Connector_FFC-FPC +JAE_FF0851SA1_2Rows-51Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0851SA1, 51 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +51 +51 +Connector_FFC-FPC +JAE_FF0871SA1_2Rows-71Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0871SA1, 71 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +71 +71 +Connector_FFC-FPC +JAE_FF0881SA1_2Rows-81Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0881SA1, 81 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +81 +81 +Connector_FFC-FPC +Molex_54132-5033_1x50-1MP_P0.5mm_Horizontal +Molex FFC/FPC connector, 50 bottom-side contacts, 0.5mm pitch, 2.0mm height, https://www.molex.com/pdm_docs/sd/541325033_sd.pdf +FFC FPC +0 +54 +51 +Connector_FFC-FPC +Molex_200528-0040_1x04-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0040, 4 Circuits (https://www.molex.com/pdm_docs/sd/2005280040_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +6 +5 +Connector_FFC-FPC +Molex_200528-0050_1x05-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0050, 5 Circuits (https://www.molex.com/pdm_docs/sd/2005280050_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +7 +6 +Connector_FFC-FPC +Molex_200528-0060_1x06-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0060, 6 Circuits (https://www.molex.com/pdm_docs/sd/2005280060_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +8 +7 +Connector_FFC-FPC +Molex_200528-0070_1x07-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0070, 7 Circuits (https://www.molex.com/pdm_docs/sd/2005280070_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +9 +8 +Connector_FFC-FPC +Molex_200528-0080_1x08-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0080, 8 Circuits (https://www.molex.com/pdm_docs/sd/2005280080_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +10 +9 +Connector_FFC-FPC +Molex_200528-0090_1x09-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0090, 9 Circuits (https://www.molex.com/pdm_docs/sd/2005280090_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +11 +10 +Connector_FFC-FPC +Molex_200528-0100_1x10-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0100, 10 Circuits (https://www.molex.com/pdm_docs/sd/2005280100_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +12 +11 +Connector_FFC-FPC +Molex_200528-0110_1x11-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0110, 11 Circuits (https://www.molex.com/pdm_docs/sd/2005280110_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +13 +12 +Connector_FFC-FPC +Molex_200528-0120_1x12-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0120, 12 Circuits (https://www.molex.com/pdm_docs/sd/2005280120_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +14 +13 +Connector_FFC-FPC +Molex_200528-0130_1x13-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0130, 13 Circuits (https://www.molex.com/pdm_docs/sd/2005280130_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +15 +14 +Connector_FFC-FPC +Molex_200528-0140_1x14-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0140, 14 Circuits (https://www.molex.com/pdm_docs/sd/2005280140_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +16 +15 +Connector_FFC-FPC +Molex_200528-0150_1x15-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0150, 15 Circuits (https://www.molex.com/pdm_docs/sd/2005280150_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +17 +16 +Connector_FFC-FPC +Molex_200528-0160_1x16-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0160, 16 Circuits (https://www.molex.com/pdm_docs/sd/2005280160_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +18 +17 +Connector_FFC-FPC +Molex_200528-0170_1x17-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0170, 17 Circuits (https://www.molex.com/pdm_docs/sd/2005280170_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +19 +18 +Connector_FFC-FPC +Molex_200528-0180_1x18-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0180, 18 Circuits (https://www.molex.com/pdm_docs/sd/2005280180_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +20 +19 +Connector_FFC-FPC +Molex_200528-0190_1x19-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0190, 19 Circuits (https://www.molex.com/pdm_docs/sd/2005280190_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +21 +20 +Connector_FFC-FPC +Molex_200528-0200_1x20-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0200, 20 Circuits (https://www.molex.com/pdm_docs/sd/2005280200_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +22 +21 +Connector_FFC-FPC +Molex_200528-0210_1x21-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0210, 21 Circuits (https://www.molex.com/pdm_docs/sd/2005280210_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +23 +22 +Connector_FFC-FPC +Molex_200528-0220_1x22-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0220, 22 Circuits (https://www.molex.com/pdm_docs/sd/2005280220_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +24 +23 +Connector_FFC-FPC +Molex_200528-0230_1x23-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0230, 23 Circuits (https://www.molex.com/pdm_docs/sd/2005280230_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +25 +24 +Connector_FFC-FPC +Molex_200528-0240_1x24-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0240, 24 Circuits (https://www.molex.com/pdm_docs/sd/2005280240_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +26 +25 +Connector_FFC-FPC +Molex_200528-0250_1x25-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0250, 25 Circuits (https://www.molex.com/pdm_docs/sd/2005280250_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +27 +26 +Connector_FFC-FPC +Molex_200528-0260_1x26-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0260, 26 Circuits (https://www.molex.com/pdm_docs/sd/2005280260_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +28 +27 +Connector_FFC-FPC +Molex_200528-0270_1x27-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0270, 27 Circuits (https://www.molex.com/pdm_docs/sd/2005280270_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +29 +28 +Connector_FFC-FPC +Molex_200528-0280_1x28-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0280, 28 Circuits (https://www.molex.com/pdm_docs/sd/2005280280_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +30 +29 +Connector_FFC-FPC +Molex_200528-0290_1x29-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0290, 29 Circuits (https://www.molex.com/pdm_docs/sd/2005280290_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +31 +30 +Connector_FFC-FPC +Molex_200528-0300_1x30-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0300, 30 Circuits (https://www.molex.com/pdm_docs/sd/2005280300_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +32 +31 +Connector_FFC-FPC +Molex_502231-1500_1x15-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 15 Circuits (https://www.molex.com/pdm_docs/sd/5022311500_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +17 +16 +Connector_FFC-FPC +Molex_502231-2400_1x24-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 24 Circuits (https://www.molex.com/pdm_docs/sd/5022312400_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +26 +25 +Connector_FFC-FPC +Molex_502231-3300_1x33-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 33 Circuits (https://www.molex.com/pdm_docs/sd/5022313300_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +36 +34 +Connector_FFC-FPC +Molex_502244-1530_1x15-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 15 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +19 +16 +Connector_FFC-FPC +Molex_502244-2430_1x24-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 24 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +28 +25 +Connector_FFC-FPC +Molex_502244-3330_1x33-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 33 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +39 +34 +Connector_FFC-FPC +Molex_502250-1791_2Rows-17Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-1791, 17 Circuits (http://www.molex.com/pdm_docs/sd/5022501791_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +19 +18 +Connector_FFC-FPC +Molex_502250-2191_2Rows-21Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2191, 21 Circuits (http://www.molex.com/pdm_docs/sd/5022502191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +23 +22 +Connector_FFC-FPC +Molex_502250-2391_2Rows-23Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2391, 23 Circuits (http://www.molex.com/pdm_docs/sd/5022502391_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +25 +24 +Connector_FFC-FPC +Molex_502250-2791_2Rows-27Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2791, 27 Circuits (http://www.molex.com/pdm_docs/sd/5022502791_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +29 +28 +Connector_FFC-FPC +Molex_502250-3391_2Rows-33Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3391, 33 Circuits (http://www.molex.com/pdm_docs/sd/5022503391_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +35 +34 +Connector_FFC-FPC +Molex_502250-3591_2Rows-35Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3591, 35 Circuits (http://www.molex.com/pdm_docs/sd/5022503591_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +37 +36 +Connector_FFC-FPC +Molex_502250-3991_2Rows-39Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3991, 39 Circuits (http://www.molex.com/pdm_docs/sd/5022503991_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +41 +40 +Connector_FFC-FPC +Molex_502250-4191_2Rows-41Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-4191, 41 Circuits (http://www.molex.com/pdm_docs/sd/5022504191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +43 +42 +Connector_FFC-FPC +Molex_502250-5191_2Rows-51Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-5191, 51 Circuits (http://www.molex.com/pdm_docs/sd/5022505191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +53 +52 +Connector_FFC-FPC +TE_0-1734839-5_1x05-1MP_P0.5mm_Horizontal +TE FPC connector, 05 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +7 +6 +Connector_FFC-FPC +TE_0-1734839-6_1x06-1MP_P0.5mm_Horizontal +TE FPC connector, 06 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +8 +7 +Connector_FFC-FPC +TE_0-1734839-7_1x07-1MP_P0.5mm_Horizontal +TE FPC connector, 07 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +9 +8 +Connector_FFC-FPC +TE_0-1734839-8_1x08-1MP_P0.5mm_Horizontal +TE FPC connector, 08 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +10 +9 +Connector_FFC-FPC +TE_0-1734839-9_1x09-1MP_P0.5mm_Horizontal +TE FPC connector, 09 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +11 +10 +Connector_FFC-FPC +TE_1-84952-0_1x10-1MP_P1.0mm_Horizontal +TE FPC connector, 10 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +12 +11 +Connector_FFC-FPC +TE_1-84952-1_1x11-1MP_P1.0mm_Horizontal +TE FPC connector, 11 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +13 +12 +Connector_FFC-FPC +TE_1-84952-2_1x12-1MP_P1.0mm_Horizontal +TE FPC connector, 12 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +14 +13 +Connector_FFC-FPC +TE_1-84952-3_1x13-1MP_P1.0mm_Horizontal +TE FPC connector, 13 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +15 +14 +Connector_FFC-FPC +TE_1-84952-4_1x14-1MP_P1.0mm_Horizontal +TE FPC connector, 14 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +16 +15 +Connector_FFC-FPC +TE_1-84952-5_1x15-1MP_P1.0mm_Horizontal +TE FPC connector, 15 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +17 +16 +Connector_FFC-FPC +TE_1-84952-6_1x16-1MP_P1.0mm_Horizontal +TE FPC connector, 16 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +18 +17 +Connector_FFC-FPC +TE_1-84952-7_1x17-1MP_P1.0mm_Horizontal +TE FPC connector, 17 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +19 +18 +Connector_FFC-FPC +TE_1-84952-8_1x18-1MP_P1.0mm_Horizontal +TE FPC connector, 18 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +20 +19 +Connector_FFC-FPC +TE_1-84952-9_1x19-1MP_P1.0mm_Horizontal +TE FPC connector, 19 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +21 +20 +Connector_FFC-FPC +TE_1-84953-0_1x10-1MP_P1.0mm_Horizontal +TE FPC connector, 10 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +12 +11 +Connector_FFC-FPC +TE_1-84953-1_1x11-1MP_P1.0mm_Horizontal +TE FPC connector, 11 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +13 +12 +Connector_FFC-FPC +TE_1-84953-2_1x12-1MP_P1.0mm_Horizontal +TE FPC connector, 12 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +14 +13 +Connector_FFC-FPC +TE_1-84953-3_1x13-1MP_P1.0mm_Horizontal +TE FPC connector, 13 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +15 +14 +Connector_FFC-FPC +TE_1-84953-4_1x14-1MP_P1.0mm_Horizontal +TE FPC connector, 14 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +16 +15 +Connector_FFC-FPC +TE_1-84953-5_1x15-1MP_P1.0mm_Horizontal +TE FPC connector, 15 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +17 +16 +Connector_FFC-FPC +TE_1-84953-6_1x16-1MP_P1.0mm_Horizontal +TE FPC connector, 16 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +18 +17 +Connector_FFC-FPC +TE_1-84953-7_1x17-1MP_P1.0mm_Horizontal +TE FPC connector, 17 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +19 +18 +Connector_FFC-FPC +TE_1-84953-8_1x18-1MP_P1.0mm_Horizontal +TE FPC connector, 18 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +20 +19 +Connector_FFC-FPC +TE_1-84953-9_1x19-1MP_P1.0mm_Horizontal +TE FPC connector, 19 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +21 +20 +Connector_FFC-FPC +TE_1-1734839-0_1x10-1MP_P0.5mm_Horizontal +TE FPC connector, 10 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +12 +11 +Connector_FFC-FPC +TE_1-1734839-1_1x11-1MP_P0.5mm_Horizontal +TE FPC connector, 11 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +13 +12 +Connector_FFC-FPC +TE_1-1734839-2_1x12-1MP_P0.5mm_Horizontal +TE FPC connector, 12 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +14 +13 +Connector_FFC-FPC +TE_1-1734839-3_1x13-1MP_P0.5mm_Horizontal +TE FPC connector, 13 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +15 +14 +Connector_FFC-FPC +TE_1-1734839-4_1x14-1MP_P0.5mm_Horizontal +TE FPC connector, 14 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +16 +15 +Connector_FFC-FPC +TE_1-1734839-5_1x15-1MP_P0.5mm_Horizontal +TE FPC connector, 15 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +17 +16 +Connector_FFC-FPC +TE_1-1734839-6_1x16-1MP_P0.5mm_Horizontal +TE FPC connector, 16 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +18 +17 +Connector_FFC-FPC +TE_1-1734839-7_1x17-1MP_P0.5mm_Horizontal +TE FPC connector, 17 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +19 +18 +Connector_FFC-FPC +TE_1-1734839-8_1x18-1MP_P0.5mm_Horizontal +TE FPC connector, 18 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +20 +19 +Connector_FFC-FPC +TE_1-1734839-9_1x19-1MP_P0.5mm_Horizontal +TE FPC connector, 19 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +21 +20 +Connector_FFC-FPC +TE_2-84952-0_1x20-1MP_P1.0mm_Horizontal +TE FPC connector, 20 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +22 +21 +Connector_FFC-FPC +TE_2-84952-1_1x21-1MP_P1.0mm_Horizontal +TE FPC connector, 21 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +23 +22 +Connector_FFC-FPC +TE_2-84952-2_1x22-1MP_P1.0mm_Horizontal +TE FPC connector, 22 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +24 +23 +Connector_FFC-FPC +TE_2-84952-3_1x23-1MP_P1.0mm_Horizontal +TE FPC connector, 23 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +25 +24 +Connector_FFC-FPC +TE_2-84952-4_1x24-1MP_P1.0mm_Horizontal +TE FPC connector, 24 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +26 +25 +Connector_FFC-FPC +TE_2-84952-5_1x25-1MP_P1.0mm_Horizontal +TE FPC connector, 25 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +27 +26 +Connector_FFC-FPC +TE_2-84952-6_1x26-1MP_P1.0mm_Horizontal +TE FPC connector, 26 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +28 +27 +Connector_FFC-FPC +TE_2-84952-7_1x27-1MP_P1.0mm_Horizontal +TE FPC connector, 27 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +29 +28 +Connector_FFC-FPC +TE_2-84952-8_1x28-1MP_P1.0mm_Horizontal +TE FPC connector, 28 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +30 +29 +Connector_FFC-FPC +TE_2-84952-9_1x29-1MP_P1.0mm_Horizontal +TE FPC connector, 29 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +31 +30 +Connector_FFC-FPC +TE_2-84953-0_1x20-1MP_P1.0mm_Horizontal +TE FPC connector, 20 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +22 +21 +Connector_FFC-FPC +TE_2-84953-1_1x21-1MP_P1.0mm_Horizontal +TE FPC connector, 21 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +23 +22 +Connector_FFC-FPC +TE_2-84953-2_1x22-1MP_P1.0mm_Horizontal +TE FPC connector, 22 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +24 +23 +Connector_FFC-FPC +TE_2-84953-3_1x23-1MP_P1.0mm_Horizontal +TE FPC connector, 23 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +25 +24 +Connector_FFC-FPC +TE_2-84953-4_1x24-1MP_P1.0mm_Horizontal +TE FPC connector, 24 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +26 +25 +Connector_FFC-FPC +TE_2-84953-5_1x25-1MP_P1.0mm_Horizontal +TE FPC connector, 25 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +27 +26 +Connector_FFC-FPC +TE_2-84953-6_1x26-1MP_P1.0mm_Horizontal +TE FPC connector, 26 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +28 +27 +Connector_FFC-FPC +TE_2-84953-7_1x27-1MP_P1.0mm_Horizontal +TE FPC connector, 27 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +29 +28 +Connector_FFC-FPC +TE_2-84953-8_1x28-1MP_P1.0mm_Horizontal +TE FPC connector, 28 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +30 +29 +Connector_FFC-FPC +TE_2-84953-9_1x29-1MP_P1.0mm_Horizontal +TE FPC connector, 29 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +31 +30 +Connector_FFC-FPC +TE_2-1734839-0_1x20-1MP_P0.5mm_Horizontal +TE FPC connector, 20 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +22 +21 +Connector_FFC-FPC +TE_2-1734839-1_1x21-1MP_P0.5mm_Horizontal +TE FPC connector, 21 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +23 +22 +Connector_FFC-FPC +TE_2-1734839-2_1x22-1MP_P0.5mm_Horizontal +TE FPC connector, 22 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +24 +23 +Connector_FFC-FPC +TE_2-1734839-3_1x23-1MP_P0.5mm_Horizontal +TE FPC connector, 23 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +25 +24 +Connector_FFC-FPC +TE_2-1734839-4_1x24-1MP_P0.5mm_Horizontal +TE FPC connector, 24 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +26 +25 +Connector_FFC-FPC +TE_2-1734839-5_1x25-1MP_P0.5mm_Horizontal +TE FPC connector, 25 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +27 +26 +Connector_FFC-FPC +TE_2-1734839-6_1x26-1MP_P0.5mm_Horizontal +TE FPC connector, 26 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +28 +27 +Connector_FFC-FPC +TE_2-1734839-7_1x27-1MP_P0.5mm_Horizontal +TE FPC connector, 27 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +29 +28 +Connector_FFC-FPC +TE_2-1734839-8_1x28-1MP_P0.5mm_Horizontal +TE FPC connector, 28 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +30 +29 +Connector_FFC-FPC +TE_2-1734839-9_1x29-1MP_P0.5mm_Horizontal +TE FPC connector, 29 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +31 +30 +Connector_FFC-FPC +TE_3-84952-0_1x30-1MP_P1.0mm_Horizontal +TE FPC connector, 30 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +32 +31 +Connector_FFC-FPC +TE_3-84953-0_1x30-1MP_P1.0mm_Horizontal +TE FPC connector, 30 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +32 +31 +Connector_FFC-FPC +TE_3-1734839-0_1x30-1MP_P0.5mm_Horizontal +TE FPC connector, 30 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +32 +31 +Connector_FFC-FPC +TE_3-1734839-1_1x31-1MP_P0.5mm_Horizontal +TE FPC connector, 31 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +33 +32 +Connector_FFC-FPC +TE_3-1734839-2_1x32-1MP_P0.5mm_Horizontal +TE FPC connector, 32 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +34 +33 +Connector_FFC-FPC +TE_3-1734839-3_1x33-1MP_P0.5mm_Horizontal +TE FPC connector, 33 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +35 +34 +Connector_FFC-FPC +TE_3-1734839-4_1x34-1MP_P0.5mm_Horizontal +TE FPC connector, 34 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +36 +35 +Connector_FFC-FPC +TE_3-1734839-5_1x35-1MP_P0.5mm_Horizontal +TE FPC connector, 35 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +37 +36 +Connector_FFC-FPC +TE_3-1734839-6_1x36-1MP_P0.5mm_Horizontal +TE FPC connector, 36 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +38 +37 +Connector_FFC-FPC +TE_3-1734839-7_1x37-1MP_P0.5mm_Horizontal +TE FPC connector, 37 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +39 +38 +Connector_FFC-FPC +TE_3-1734839-8_1x38-1MP_P0.5mm_Horizontal +TE FPC connector, 38 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +40 +39 +Connector_FFC-FPC +TE_3-1734839-9_1x39-1MP_P0.5mm_Horizontal +TE FPC connector, 39 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +41 +40 +Connector_FFC-FPC +TE_4-1734839-0_1x40-1MP_P0.5mm_Horizontal +TE FPC connector, 40 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +42 +41 +Connector_FFC-FPC +TE_4-1734839-1_1x41-1MP_P0.5mm_Horizontal +TE FPC connector, 41 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +43 +42 +Connector_FFC-FPC +TE_4-1734839-2_1x42-1MP_P0.5mm_Horizontal +TE FPC connector, 42 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +44 +43 +Connector_FFC-FPC +TE_4-1734839-3_1x43-1MP_P0.5mm_Horizontal +TE FPC connector, 43 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +45 +44 +Connector_FFC-FPC +TE_4-1734839-4_1x44-1MP_P0.5mm_Horizontal +TE FPC connector, 44 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +46 +45 +Connector_FFC-FPC +TE_4-1734839-5_1x45-1MP_P0.5mm_Horizontal +TE FPC connector, 45 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +47 +46 +Connector_FFC-FPC +TE_4-1734839-6_1x46-1MP_P0.5mm_Horizontal +TE FPC connector, 46 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +48 +47 +Connector_FFC-FPC +TE_4-1734839-7_1x47-1MP_P0.5mm_Horizontal +TE FPC connector, 47 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +49 +48 +Connector_FFC-FPC +TE_4-1734839-8_1x48-1MP_P0.5mm_Horizontal +TE FPC connector, 48 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +50 +49 +Connector_FFC-FPC +TE_4-1734839-9_1x49-1MP_P0.5mm_Horizontal +TE FPC connector, 49 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +51 +50 +Connector_FFC-FPC +TE_5-1734839-0_1x50-1MP_P0.5mm_Horizontal +TE FPC connector, 50 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +52 +51 +Connector_FFC-FPC +TE_84952-4_1x04-1MP_P1.0mm_Horizontal +TE FPC connector, 04 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +6 +5 +Connector_FFC-FPC +TE_84952-5_1x05-1MP_P1.0mm_Horizontal +TE FPC connector, 05 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +7 +6 +Connector_FFC-FPC +TE_84952-6_1x06-1MP_P1.0mm_Horizontal +TE FPC connector, 06 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +8 +7 +Connector_FFC-FPC +TE_84952-7_1x07-1MP_P1.0mm_Horizontal +TE FPC connector, 07 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +9 +8 +Connector_FFC-FPC +TE_84952-8_1x08-1MP_P1.0mm_Horizontal +TE FPC connector, 08 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +10 +9 +Connector_FFC-FPC +TE_84952-9_1x09-1MP_P1.0mm_Horizontal +TE FPC connector, 09 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +11 +10 +Connector_FFC-FPC +TE_84953-4_1x04-1MP_P1.0mm_Horizontal +TE FPC connector, 04 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +6 +5 +Connector_FFC-FPC +TE_84953-5_1x05-1MP_P1.0mm_Horizontal +TE FPC connector, 05 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +7 +6 +Connector_FFC-FPC +TE_84953-6_1x06-1MP_P1.0mm_Horizontal +TE FPC connector, 06 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +8 +7 +Connector_FFC-FPC +TE_84953-7_1x07-1MP_P1.0mm_Horizontal +TE FPC connector, 07 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +9 +8 +Connector_FFC-FPC +TE_84953-8_1x08-1MP_P1.0mm_Horizontal +TE FPC connector, 08 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +10 +9 +Connector_FFC-FPC +TE_84953-9_1x09-1MP_P1.0mm_Horizontal +TE FPC connector, 09 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +11 +10 +Connector_FFC-FPC +Wuerth_68611214422_1x12-1MP_P1.0mm_Horizontal +http://katalog.we-online.de/em/datasheet/68611214422.pdf +Wuerth FPC 68611214422 connector 12 bottom-side contacts 1.0mm pitch 1.0mm height SMT +0 +14 +13 +Connector_HDMI +HDMI_A_Contact_Technology_HDMI-19APL2_Horizontal +HDMI Contact Technology Type A http://www.contactswitch.com/en/download.aspx?id=1449 +HDMI Contact Technology Type A +0 +23 +20 +Connector_HDMI +HDMI_A_Kycon_KDMIX-SL1-NS-WS-B15_VerticalRightAngle +HDMI, Type A, Kycon KDMIX-SL1-NS-WS-B15, Vertical Right Angle, http://www.kycon.com/Pub_Eng_Draw/KDMIX-SL1-NS-WS-B15.pdf +hdmi type a +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-0x01 +HDMI, Micro, Type D, SMD, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle smd +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-1x01 +HDMI, Micro, Type D, THT, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle tht +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-2x0x +HDMI, Micro, Type D, THT/SMD hybrid, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle tht smd hybrid +0 +23 +20 +Connector_Harwin +Harwin_Gecko-G125-FVX0605L0X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row female, vertical entry, PN:G125-FVX0605L0X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-FVX1005L0X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row female, vertical entry, PN:G125-FVX1005L0X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-FVX1205L0X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row female, vertical entry, PN:G125-FVX1205L0X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-FVX1605L0X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row female, vertical entry, PN:G125-FVX1605L0X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-FVX2005L0X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row female, vertical entry, PN:G125-FVX2005L0X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-FVX2605L0X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row female, vertical entry, PN:G125-FVX2605L0X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-FVX3405L0X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row female, vertical entry, PN:G125-FVX3405L0X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-FVX5005L0X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row female, vertical entry, PN:G125-FVX5005L0X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_Gecko-G125-MVX0605L0X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row male, vertical entry, no latches, PN:G125-MVX0605L0X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-MVX0605L1X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row male, vertical entry, with latches, PN:G125-MVX0605L1X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-MVX1005L0X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row male, vertical entry, no latches, PN:G125-MVX1005L0X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-MVX1005L1X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row male, vertical entry, with latches, PN:G125-MVX1005L1X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-MVX1205L0X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row male, vertical entry, no latches, PN:G125-MVX1205L0X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-MVX1205L1X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row male, vertical entry, with latches, PN:G125-MVX1205L1X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-MVX1605L0X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row male, vertical entry, no latches, PN:G125-MVX1605L0X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-MVX1605L1X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row male, vertical entry, with latches, PN:G125-MVX1605L1X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-MVX2005L0X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row male, vertical entry, no latches, PN:G125-MVX2005L0X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-MVX2005L1X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row male, vertical entry, with latches, PN:G125-MVX2005L1X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-MVX2605L0X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row male, vertical entry, no latches, PN:G125-MVX2605L0X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-MVX2605L1X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row male, vertical entry, with latches, PN:G125-MVX2605L1X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-MVX3405L0X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row male, vertical entry, no latches, PN:G125-MVX3405L0X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-MVX3405L1X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row male, vertical entry, with latches, PN:G125-MVX3405L1X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-MVX5005L0X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row male, vertical entry, no latches, PN:G125-MVX5005L0X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_Gecko-G125-MVX5005L1X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row male, vertical entry, with latches, PN:G125-MVX5005L1X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_LTek-Male_02_P2.00mm_Vertical +Harwin LTek Connector, 2 pins, single row male, vertical entry +connector harwin ltek M80 +0 +2 +2 +Connector_Harwin +Harwin_LTek-Male_02_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 2 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +6 +2 +Connector_Harwin +Harwin_LTek-Male_2x02_P2.00mm_Vertical +Harwin LTek Connector, 4 pins, single row male, vertical entry +connector harwin ltek M80 +0 +4 +4 +Connector_Harwin +Harwin_LTek-Male_2x02_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 4 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +8 +4 +Connector_Harwin +Harwin_LTek-Male_2x03_P2.00mm_Vertical +Harwin LTek Connector, 6 pins, single row male, vertical entry +connector harwin ltek M80 +0 +6 +6 +Connector_Harwin +Harwin_LTek-Male_2x03_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 6 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +10 +6 +Connector_Harwin +Harwin_LTek-Male_2x04_P2.00mm_Vertical +Harwin LTek Connector, 8 pins, single row male, vertical entry +connector harwin ltek M80 +0 +8 +8 +Connector_Harwin +Harwin_LTek-Male_2x04_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 8 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +12 +8 +Connector_Harwin +Harwin_LTek-Male_2x05_P2.00mm_Vertical +Harwin LTek Connector, 10 pins, single row male, vertical entry +connector harwin ltek M80 +0 +10 +10 +Connector_Harwin +Harwin_LTek-Male_2x05_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 10 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +14 +10 +Connector_Harwin +Harwin_LTek-Male_2x06_P2.00mm_Vertical +Harwin LTek Connector, 12 pins, single row male, vertical entry +connector harwin ltek M80 +0 +12 +12 +Connector_Harwin +Harwin_LTek-Male_2x06_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 12 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +16 +12 +Connector_Harwin +Harwin_LTek-Male_2x07_P2.00mm_Vertical +Harwin LTek Connector, 14 pins, single row male, vertical entry +connector harwin ltek M80 +0 +14 +14 +Connector_Harwin +Harwin_LTek-Male_2x07_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 14 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +18 +14 +Connector_Harwin +Harwin_LTek-Male_2x08_P2.00mm_Vertical +Harwin LTek Connector, 16 pins, single row male, vertical entry +connector harwin ltek M80 +0 +16 +16 +Connector_Harwin +Harwin_LTek-Male_2x08_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 16 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +20 +16 +Connector_Harwin +Harwin_LTek-Male_2x09_P2.00mm_Vertical +Harwin LTek Connector, 18 pins, single row male, vertical entry +connector harwin ltek M80 +0 +18 +18 +Connector_Harwin +Harwin_LTek-Male_2x09_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 18 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +22 +18 +Connector_Harwin +Harwin_LTek-Male_2x10_P2.00mm_Vertical +Harwin LTek Connector, 20 pins, single row male, vertical entry +connector harwin ltek M80 +0 +20 +20 +Connector_Harwin +Harwin_LTek-Male_2x10_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 20 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +24 +20 +Connector_Harwin +Harwin_LTek-Male_2x13_P2.00mm_Vertical +Harwin LTek Connector, 26 pins, single row male, vertical entry +connector harwin ltek M80 +0 +26 +26 +Connector_Harwin +Harwin_LTek-Male_2x13_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 26 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +30 +26 +Connector_Harwin +Harwin_LTek-Male_2x17_P2.00mm_Vertical +Harwin LTek Connector, 34 pins, single row male, vertical entry +connector harwin ltek M80 +0 +34 +34 +Connector_Harwin +Harwin_LTek-Male_2x17_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 34 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +38 +34 +Connector_Harwin +Harwin_LTek-Male_2x22_P2.00mm_Vertical +Harwin LTek Connector, 44 pins, single row male, vertical entry +connector harwin ltek M80 +0 +44 +44 +Connector_Harwin +Harwin_LTek-Male_2x22_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 44 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +48 +44 +Connector_Harwin +Harwin_LTek-Male_03_P2.00mm_Vertical +Harwin LTek Connector, 3 pins, single row male, vertical entry +connector harwin ltek M80 +0 +3 +3 +Connector_Harwin +Harwin_LTek-Male_03_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 3 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +7 +3 +Connector_Harwin +Harwin_LTek-Male_04_P2.00mm_Vertical +Harwin LTek Connector, 4 pins, single row male, vertical entry +connector harwin ltek M80 +0 +4 +4 +Connector_Harwin +Harwin_LTek-Male_04_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 4 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +8 +4 +Connector_Harwin +Harwin_LTek-Male_05_P2.00mm_Vertical +Harwin LTek Connector, 5 pins, single row male, vertical entry +connector harwin ltek M80 +0 +5 +5 +Connector_Harwin +Harwin_LTek-Male_05_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 5 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +9 +5 +Connector_Harwin +Harwin_LTek-Male_06_P2.00mm_Vertical +Harwin LTek Connector, 6 pins, single row male, vertical entry +connector harwin ltek M80 +0 +6 +6 +Connector_Harwin +Harwin_LTek-Male_06_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 6 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +10 +6 +Connector_Harwin +Harwin_LTek-Male_07_P2.00mm_Vertical +Harwin LTek Connector, 7 pins, single row male, vertical entry +connector harwin ltek M80 +0 +7 +7 +Connector_Harwin +Harwin_LTek-Male_07_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 7 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +11 +7 +Connector_Harwin +Harwin_LTek-Male_17_P2.00mm_Vertical +Harwin LTek Connector, 17 pins, single row male, vertical entry +connector harwin ltek M80 +0 +17 +17 +Connector_Harwin +Harwin_LTek-Male_17_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 17 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +21 +17 +Connector_Harwin +Harwin_LTek-Male_22_P2.00mm_Vertical +Harwin LTek Connector, 22 pins, single row male, vertical entry +connector harwin ltek M80 +0 +22 +22 +Connector_Harwin +Harwin_LTek-Male_22_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 22 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +26 +22 +Connector_Harwin +Harwin_M20-89003xx_1x03_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89003xx, 3 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +4 +3 +Connector_Harwin +Harwin_M20-89004xx_1x04_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89004xx, 4 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +5 +4 +Connector_Harwin +Harwin_M20-89005xx_1x05_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89005xx, 5 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +6 +5 +Connector_Harwin +Harwin_M20-89006xx_1x06_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89006xx, 6 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +7 +6 +Connector_Harwin +Harwin_M20-89007xx_1x07_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89007xx, 7 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +8 +7 +Connector_Harwin +Harwin_M20-89008xx_1x08_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89008xx, 8 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +9 +8 +Connector_Harwin +Harwin_M20-89009xx_1x09_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89009xx, 9 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +10 +9 +Connector_Harwin +Harwin_M20-89010xx_1x10_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89010xx, 10 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +11 +10 +Connector_Harwin +Harwin_M20-89011xx_1x11_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89011xx, 11 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +12 +11 +Connector_Harwin +Harwin_M20-89012xx_1x12_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89012xx, 12 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +13 +12 +Connector_Harwin +Harwin_M20-89013xx_1x13_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89013xx, 13 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +14 +13 +Connector_Harwin +Harwin_M20-89014xx_1x14_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89014xx, 14 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +15 +14 +Connector_Harwin +Harwin_M20-89015xx_1x15_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89015xx, 15 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +16 +15 +Connector_Harwin +Harwin_M20-89016xx_1x16_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89016xx, 16 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +17 +16 +Connector_Harwin +Harwin_M20-89017xx_1x17_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89017xx, 17 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +18 +17 +Connector_Harwin +Harwin_M20-89018xx_1x18_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89018xx, 18 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +19 +18 +Connector_Harwin +Harwin_M20-89019xx_1x19_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89019xx, 19 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +20 +19 +Connector_Harwin +Harwin_M20-89020xx_1x20_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89020xx, 20 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +21 +20 +Connector_Harwin +Harwin_M20-7810245_2x02_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810245, 2 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +4 +4 +Connector_Harwin +Harwin_M20-7810345_2x03_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810345, 3 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +6 +6 +Connector_Harwin +Harwin_M20-7810445_2x04_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810445, 4 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +8 +8 +Connector_Harwin +Harwin_M20-7810545_2x05_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810545, 5 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +10 +10 +Connector_Harwin +Harwin_M20-7810645_2x06_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810645, 6 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +12 +12 +Connector_Harwin +Harwin_M20-7810745_2x07_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810745, 7 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +14 +14 +Connector_Harwin +Harwin_M20-7810845_2x08_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810845, 8 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +16 +16 +Connector_Harwin +Harwin_M20-7810945_2x09_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810945, 9 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +18 +18 +Connector_Harwin +Harwin_M20-7811045_2x10_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811045, 10 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +20 +20 +Connector_Harwin +Harwin_M20-7811245_2x12_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811245, 12 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +24 +24 +Connector_Harwin +Harwin_M20-7811545_2x15_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811545, 15 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +30 +30 +Connector_Harwin +Harwin_M20-7812045_2x20_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7812045, 20 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +40 +40 +Connector_Hirose +Hirose_BM24_BM24-40DP-2-0.35V_2x20_P0.35mm_PowerPin2_Vertical +Hirose BM24 series connector, BM24-40DP/2-0.35V (https://www.hirose.com/product/en/download_file/key_name/BM24/category/Catalog/doc_file_id/47680/?file_category_id=4&item_id=50&is_series=1) +connector Hirose BM24 40pin header +0 +44 +42 +Connector_Hirose +Hirose_BM24_BM24-40DS-2-0.35V_2x20_P0.35mm_PowerPin2_Vertical +Hirose BM24 series connector, BM24-40DS/2-0.35V (https://www.hirose.com/product/en/download_file/key_name/BM24/category/Catalog/doc_file_id/47680/?file_category_id=4&item_id=50&is_series=1) +connector Hirose 40pin receptacle vertical +0 +42 +42 +Connector_Hirose +Hirose_DF3EA-02P-2H_1x02-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-02P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +4 +3 +Connector_Hirose +Hirose_DF3EA-03P-2H_1x03-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-03P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +5 +4 +Connector_Hirose +Hirose_DF3EA-04P-2H_1x04-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-04P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +6 +5 +Connector_Hirose +Hirose_DF3EA-05P-2H_1x05-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-05P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +7 +6 +Connector_Hirose +Hirose_DF3EA-06P-2H_1x06-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-06P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +8 +7 +Connector_Hirose +Hirose_DF3EA-07P-2H_1x07-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-07P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +9 +8 +Connector_Hirose +Hirose_DF3EA-08P-2H_1x08-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-08P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +10 +9 +Connector_Hirose +Hirose_DF3EA-09P-2H_1x09-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-09P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +11 +10 +Connector_Hirose +Hirose_DF3EA-10P-2H_1x10-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-10P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +12 +11 +Connector_Hirose +Hirose_DF3EA-11P-2H_1x11-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-11P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +13 +12 +Connector_Hirose +Hirose_DF3EA-12P-2H_1x12-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-12P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +14 +13 +Connector_Hirose +Hirose_DF3EA-13P-2H_1x13-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-13P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +15 +14 +Connector_Hirose +Hirose_DF3EA-14P-2H_1x14-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-14P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +16 +15 +Connector_Hirose +Hirose_DF3EA-15P-2H_1x15-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-15P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +17 +16 +Connector_Hirose +Hirose_DF11-4DP-2DSA_2x02_P2.00mm_Vertical +Hirose DF11 through hole, DF11-4DP-2DSA, 2 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF11-6DP-2DSA_2x03_P2.00mm_Vertical +Hirose DF11 through hole, DF11-6DP-2DSA, 3 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF11-8DP-2DSA_2x04_P2.00mm_Vertical +Hirose DF11 through hole, DF11-8DP-2DSA, 4 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +8 +8 +Connector_Hirose +Hirose_DF11-10DP-2DSA_2x05_P2.00mm_Vertical +Hirose DF11 through hole, DF11-10DP-2DSA, 5 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +10 +10 +Connector_Hirose +Hirose_DF11-12DP-2DSA_2x06_P2.00mm_Vertical +Hirose DF11 through hole, DF11-12DP-2DSA, 6 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +12 +12 +Connector_Hirose +Hirose_DF11-14DP-2DSA_2x07_P2.00mm_Vertical +Hirose DF11 through hole, DF11-14DP-2DSA, 7 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +14 +14 +Connector_Hirose +Hirose_DF11-16DP-2DSA_2x08_P2.00mm_Vertical +Hirose DF11 through hole, DF11-16DP-2DSA, 8 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +16 +16 +Connector_Hirose +Hirose_DF11-18DP-2DSA_2x09_P2.00mm_Vertical +Hirose DF11 through hole, DF11-18DP-2DSA, 9 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +18 +18 +Connector_Hirose +Hirose_DF11-20DP-2DSA_2x10_P2.00mm_Vertical +Hirose DF11 through hole, DF11-20DP-2DSA, 10 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +20 +20 +Connector_Hirose +Hirose_DF11-22DP-2DSA_2x11_P2.00mm_Vertical +Hirose DF11 through hole, DF11-22DP-2DSA, 11 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +22 +22 +Connector_Hirose +Hirose_DF11-24DP-2DSA_2x12_P2.00mm_Vertical +Hirose DF11 through hole, DF11-24DP-2DSA, 12 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +24 +24 +Connector_Hirose +Hirose_DF11-26DP-2DSA_2x13_P2.00mm_Vertical +Hirose DF11 through hole, DF11-26DP-2DSA, 13 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +26 +26 +Connector_Hirose +Hirose_DF11-28DP-2DSA_2x14_P2.00mm_Vertical +Hirose DF11 through hole, DF11-28DP-2DSA, 14 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +28 +28 +Connector_Hirose +Hirose_DF11-30DP-2DSA_2x15_P2.00mm_Vertical +Hirose DF11 through hole, DF11-30DP-2DSA, 15 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +30 +30 +Connector_Hirose +Hirose_DF11-32DP-2DSA_2x16_P2.00mm_Vertical +Hirose DF11 through hole, DF11-32DP-2DSA, 16 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +32 +32 +Connector_Hirose +Hirose_DF12_DF12C3.0-10DS-0.5V_2x05_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-10DS-0.5V, 10 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +20 +10 +Connector_Hirose +Hirose_DF12_DF12C3.0-14DS-0.5V_2x07_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-14DS-0.5V, 14 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +28 +14 +Connector_Hirose +Hirose_DF12_DF12C3.0-20DS-0.5V_2x10_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-20DS-0.5V, 20 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +40 +20 +Connector_Hirose +Hirose_DF12_DF12C3.0-30DS-0.5V_2x15_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-30DS-0.5V, 30 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +60 +30 +Connector_Hirose +Hirose_DF12_DF12C3.0-32DS-0.5V_2x16_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-32DS-0.5V, 32 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +64 +32 +Connector_Hirose +Hirose_DF12_DF12C3.0-36DS-0.5V_2x18_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-36DS-0.5V, 36 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +72 +36 +Connector_Hirose +Hirose_DF12_DF12C3.0-40DS-0.5V_2x20_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-40DS-0.5V, 40 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +80 +40 +Connector_Hirose +Hirose_DF12_DF12C3.0-50DS-0.5V_2x25_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-50DS-0.5V, 50 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +100 +50 +Connector_Hirose +Hirose_DF12_DF12C3.0-60DS-0.5V_2x30_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-60DS-0.5V, 60 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +120 +60 +Connector_Hirose +Hirose_DF12_DF12E3.0-10DP-0.5V_2x05_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-10DP-0.5V, 10 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +20 +10 +Connector_Hirose +Hirose_DF12_DF12E3.0-14DP-0.5V_2x07_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-14DP-0.5V, 14 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +28 +14 +Connector_Hirose +Hirose_DF12_DF12E3.0-20DP-0.5V_2x10_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-20DP-0.5V, 20 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +40 +20 +Connector_Hirose +Hirose_DF12_DF12E3.0-30DP-0.5V_2x15_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-30DP-0.5V, 30 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +60 +30 +Connector_Hirose +Hirose_DF12_DF12E3.0-32DP-0.5V_2x16_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-32DP-0.5V, 32 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +64 +32 +Connector_Hirose +Hirose_DF12_DF12E3.0-36DP-0.5V_2x18_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-36DP-0.5V, 36 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +72 +36 +Connector_Hirose +Hirose_DF12_DF12E3.0-40DP-0.5V_2x20_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-40DP-0.5V, 40 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +80 +40 +Connector_Hirose +Hirose_DF12_DF12E3.0-50DP-0.5V_2x25_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-50DP-0.5V, 50 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +100 +50 +Connector_Hirose +Hirose_DF12_DF12E3.0-60DP-0.5V_2x30_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-60DP-0.5V, 60 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +120 +60 +Connector_Hirose +Hirose_DF12_DF12E3.0-80DP-0.5V_2x40_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-80DP-0.5V, 80 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +160 +80 +Connector_Hirose +Hirose_DF13-02P-1.25DSA_1x02_P1.25mm_Vertical +Hirose DF13 through hole, DF13-02P-1.25DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF13-02P-1.25DS_1x02_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-02P-1.25DS, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +2 +2 +Connector_Hirose +Hirose_DF13-03P-1.25DSA_1x03_P1.25mm_Vertical +Hirose DF13 through hole, DF13-03P-1.25DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF13-03P-1.25DS_1x03_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-03P-1.25DS, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +3 +3 +Connector_Hirose +Hirose_DF13-04P-1.25DSA_1x04_P1.25mm_Vertical +Hirose DF13 through hole, DF13-04P-1.25DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF13-04P-1.25DS_1x04_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-04P-1.25DS, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +4 +4 +Connector_Hirose +Hirose_DF13-05P-1.25DSA_1x05_P1.25mm_Vertical +Hirose DF13 through hole, DF13-05P-1.25DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +5 +5 +Connector_Hirose +Hirose_DF13-05P-1.25DS_1x05_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-05P-1.25DS, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +5 +5 +Connector_Hirose +Hirose_DF13-06P-1.25DSA_1x06_P1.25mm_Vertical +Hirose DF13 through hole, DF13-06P-1.25DSA, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF13-06P-1.25DS_1x06_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-06P-1.25DS, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +6 +6 +Connector_Hirose +Hirose_DF13-07P-1.25DSA_1x07_P1.25mm_Vertical +Hirose DF13 through hole, DF13-07P-1.25DSA, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +7 +7 +Connector_Hirose +Hirose_DF13-07P-1.25DS_1x07_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-07P-1.25DS, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +7 +7 +Connector_Hirose +Hirose_DF13-08P-1.25DSA_1x08_P1.25mm_Vertical +Hirose DF13 through hole, DF13-08P-1.25DSA, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +8 +8 +Connector_Hirose +Hirose_DF13-08P-1.25DS_1x08_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-08P-1.25DS, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +8 +8 +Connector_Hirose +Hirose_DF13-09P-1.25DSA_1x09_P1.25mm_Vertical +Hirose DF13 through hole, DF13-09P-1.25DSA, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +9 +9 +Connector_Hirose +Hirose_DF13-09P-1.25DS_1x09_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-09P-1.25DS, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +9 +9 +Connector_Hirose +Hirose_DF13-10P-1.25DSA_1x10_P1.25mm_Vertical +Hirose DF13 through hole, DF13-10P-1.25DSA, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +10 +10 +Connector_Hirose +Hirose_DF13-10P-1.25DS_1x10_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-10P-1.25DS, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +10 +10 +Connector_Hirose +Hirose_DF13-11P-1.25DSA_1x11_P1.25mm_Vertical +Hirose DF13 through hole, DF13-11P-1.25DSA, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +11 +11 +Connector_Hirose +Hirose_DF13-11P-1.25DS_1x11_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-11P-1.25DS, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +11 +11 +Connector_Hirose +Hirose_DF13-12P-1.25DSA_1x12_P1.25mm_Vertical +Hirose DF13 through hole, DF13-12P-1.25DSA, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +12 +12 +Connector_Hirose +Hirose_DF13-12P-1.25DS_1x12_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-12P-1.25DS, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +12 +12 +Connector_Hirose +Hirose_DF13-13P-1.25DSA_1x13_P1.25mm_Vertical +Hirose DF13 through hole, DF13-13P-1.25DSA, 13 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +13 +13 +Connector_Hirose +Hirose_DF13-14P-1.25DSA_1x14_P1.25mm_Vertical +Hirose DF13 through hole, DF13-14P-1.25DSA, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +14 +14 +Connector_Hirose +Hirose_DF13-14P-1.25DS_1x14_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-14P-1.25DS, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +14 +14 +Connector_Hirose +Hirose_DF13-15P-1.25DSA_1x15_P1.25mm_Vertical +Hirose DF13 through hole, DF13-15P-1.25DSA, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +15 +15 +Connector_Hirose +Hirose_DF13-15P-1.25DS_1x15_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-15P-1.25DS, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +15 +15 +Connector_Hirose +Hirose_DF13C_CL535-0402-2-51_1x02-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0402-2-51, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +4 +3 +Connector_Hirose +Hirose_DF13C_CL535-0403-5-51_1x03-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0403-5-51, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +5 +4 +Connector_Hirose +Hirose_DF13C_CL535-0404-8-51_1x04-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0404-8-51, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +6 +5 +Connector_Hirose +Hirose_DF13C_CL535-0405-0-51_1x05-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0405-0-51, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +7 +6 +Connector_Hirose +Hirose_DF13C_CL535-0406-3-51_1x06-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0406-3-51, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +8 +7 +Connector_Hirose +Hirose_DF13C_CL535-0407-6-51_1x07-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0407-6-51, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +9 +8 +Connector_Hirose +Hirose_DF13C_CL535-0408-9-51_1x08-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0408-9-51, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +10 +9 +Connector_Hirose +Hirose_DF13C_CL535-0409-1-51_1x09-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0409-1-51, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +11 +10 +Connector_Hirose +Hirose_DF13C_CL535-0410-4-51_1x10-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0410-4-51, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +12 +11 +Connector_Hirose +Hirose_DF13C_CL535-0411-3-51_1x11-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0411-3-51, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +13 +12 +Connector_Hirose +Hirose_DF13C_CL535-0412-6-51_1x12-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0412-6-51, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +14 +13 +Connector_Hirose +Hirose_DF13C_CL535-0414-1-51_1x14-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0414-1-51, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +16 +15 +Connector_Hirose +Hirose_DF13C_CL535-0415-4-51_1x15-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0415-4-51, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +17 +16 +Connector_Hirose +Hirose_DF52-2S-0.8H_1x02-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-2S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +4 +3 +Connector_Hirose +Hirose_DF52-3S-0.8H_1x03-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-3S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +5 +4 +Connector_Hirose +Hirose_DF52-4S-0.8H_1x04-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-4S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +6 +5 +Connector_Hirose +Hirose_DF52-5S-0.8H_1x05-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-5S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +7 +6 +Connector_Hirose +Hirose_DF52-6S-0.8H_1x06-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-6S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +8 +7 +Connector_Hirose +Hirose_DF52-7S-0.8H_1x07-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-7S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +9 +8 +Connector_Hirose +Hirose_DF52-8S-0.8H_1x08-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-8S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +10 +9 +Connector_Hirose +Hirose_DF52-9S-0.8H_1x09-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-9S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +11 +10 +Connector_Hirose +Hirose_DF52-10S-0.8H_1x10-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-10S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +12 +11 +Connector_Hirose +Hirose_DF52-11S-0.8H_1x11-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-11S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +13 +12 +Connector_Hirose +Hirose_DF52-12S-0.8H_1x12-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-12S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +14 +13 +Connector_Hirose +Hirose_DF52-14S-0.8H_1x14-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-14S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +16 +15 +Connector_Hirose +Hirose_DF52-15S-0.8H_1x15-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-15S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +17 +16 +Connector_Hirose +Hirose_DF63-5P-3.96DSA_1x05_P3.96mm_Vertical +Hirose DF63 through hole, DF63-5P-3.96DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +5 +5 +Connector_Hirose +Hirose_DF63-6P-3.96DSA_1x06_P3.96mm_Vertical +Hirose DF63 through hole, DF63-6P-3.96DSA, 6 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF63M-1P-3.96DSA_1x01_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-1P-3.96DSA, 1 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +1 +1 +Connector_Hirose +Hirose_DF63M-2P-3.96DSA_1x02_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-2P-3.96DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF63M-3P-3.96DSA_1x03_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-3P-3.96DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF63M-4P-3.96DSA_1x04_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-4P-3.96DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF63R-1P-3.96DSA_1x01_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-1P-3.96DSA, 1 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +1 +1 +Connector_Hirose +Hirose_DF63R-2P-3.96DSA_1x02_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-2P-3.96DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF63R-3P-3.96DSA_1x03_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-3P-3.96DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF63R-4P-3.96DSA_1x04_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-4P-3.96DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF63R-5P-3.96DSA_1x05_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-5P-3.96DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +5 +5 +Connector_IDC +IDC-Header_2x03_P2.54mm_Horizontal +Through hole IDC box header, 2x03, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x03 2.54mm double row +0 +6 +6 +Connector_IDC +IDC-Header_2x03_P2.54mm_Vertical +Through hole IDC box header, 2x03, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x03 2.54mm double row +0 +6 +6 +Connector_IDC +IDC-Header_2x04_P2.54mm_Horizontal +Through hole IDC box header, 2x04, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x04 2.54mm double row +0 +8 +8 +Connector_IDC +IDC-Header_2x04_P2.54mm_Vertical +Through hole IDC box header, 2x04, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x04 2.54mm double row +0 +8 +8 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05_P2.54mm_Horizontal +Through hole IDC box header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Vertical +Through hole IDC box header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06_P2.54mm_Horizontal +Through hole IDC box header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Vertical +Through hole IDC box header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07_P2.54mm_Horizontal +Through hole IDC box header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Horizontal_Lock +Connector IDC Locked, 10 contacts, compatible header: PANCON HE10 (Series 50, (https://www.reboul.fr/storage/00003af6.pdf) +connector idc locked +0 +16 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Vertical +Through hole IDC box header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08_P2.54mm_Horizontal +Through hole IDC box header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Vertical +Through hole IDC box header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10_P2.54mm_Horizontal +Through hole IDC box header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Vertical +Through hole IDC box header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12_P2.54mm_Horizontal +Through hole IDC box header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Vertical +Through hole IDC box header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13_P2.54mm_Horizontal +Through hole IDC box header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Vertical +Through hole IDC box header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15_P2.54mm_Horizontal +Through hole IDC box header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Vertical +Through hole IDC box header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17_P2.54mm_Horizontal +Through hole IDC box header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Vertical +Through hole IDC box header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20_P2.54mm_Horizontal +Through hole IDC box header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Vertical +Through hole IDC box header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25_P2.54mm_Horizontal +Through hole IDC box header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Vertical +Through hole IDC box header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30_P2.54mm_Horizontal +Through hole IDC box header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Vertical +Through hole IDC box header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32_P2.54mm_Horizontal +Through hole IDC box header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Vertical +Through hole IDC box header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x32 2.54mm double row +0 +64 +64 +Connector_JAE +JAE_LY20-4P-DLT1_2x02_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-4P-DLT1, 2 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +4 +4 +Connector_JAE +JAE_LY20-4P-DT1_2x02_P2.00mm_Vertical +Molex LY 20 series connector, LY20-4P-DT1, 2 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +4 +4 +Connector_JAE +JAE_LY20-6P-DLT1_2x03_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-6P-DLT1, 3 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +6 +6 +Connector_JAE +JAE_LY20-6P-DT1_2x03_P2.00mm_Vertical +Molex LY 20 series connector, LY20-6P-DT1, 3 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +6 +6 +Connector_JAE +JAE_LY20-8P-DLT1_2x04_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-8P-DLT1, 4 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +8 +8 +Connector_JAE +JAE_LY20-8P-DT1_2x04_P2.00mm_Vertical +Molex LY 20 series connector, LY20-8P-DT1, 4 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +8 +8 +Connector_JAE +JAE_LY20-10P-DLT1_2x05_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-10P-DLT1, 5 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +10 +10 +Connector_JAE +JAE_LY20-10P-DT1_2x05_P2.00mm_Vertical +Molex LY 20 series connector, LY20-10P-DT1, 5 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +10 +10 +Connector_JAE +JAE_LY20-12P-DLT1_2x06_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-12P-DLT1, 6 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +12 +12 +Connector_JAE +JAE_LY20-12P-DT1_2x06_P2.00mm_Vertical +Molex LY 20 series connector, LY20-12P-DT1, 6 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +12 +12 +Connector_JAE +JAE_LY20-14P-DLT1_2x07_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-14P-DLT1, 7 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +14 +14 +Connector_JAE +JAE_LY20-14P-DT1_2x07_P2.00mm_Vertical +Molex LY 20 series connector, LY20-14P-DT1, 7 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +14 +14 +Connector_JAE +JAE_LY20-16P-DLT1_2x08_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-16P-DLT1, 8 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +16 +16 +Connector_JAE +JAE_LY20-16P-DT1_2x08_P2.00mm_Vertical +Molex LY 20 series connector, LY20-16P-DT1, 8 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +16 +16 +Connector_JAE +JAE_LY20-18P-DLT1_2x09_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-18P-DLT1, 9 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +18 +18 +Connector_JAE +JAE_LY20-18P-DT1_2x09_P2.00mm_Vertical +Molex LY 20 series connector, LY20-18P-DT1, 9 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +18 +18 +Connector_JAE +JAE_LY20-20P-DLT1_2x10_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-20P-DLT1, 10 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +20 +20 +Connector_JAE +JAE_LY20-20P-DT1_2x10_P2.00mm_Vertical +Molex LY 20 series connector, LY20-20P-DT1, 10 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +20 +20 +Connector_JAE +JAE_LY20-22P-DLT1_2x11_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-22P-DLT1, 11 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +22 +22 +Connector_JAE +JAE_LY20-22P-DT1_2x11_P2.00mm_Vertical +Molex LY 20 series connector, LY20-22P-DT1, 11 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +22 +22 +Connector_JAE +JAE_LY20-24P-DLT1_2x12_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-24P-DLT1, 12 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +24 +24 +Connector_JAE +JAE_LY20-24P-DT1_2x12_P2.00mm_Vertical +Molex LY 20 series connector, LY20-24P-DT1, 12 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +24 +24 +Connector_JAE +JAE_LY20-26P-DLT1_2x13_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-26P-DLT1, 13 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +26 +26 +Connector_JAE +JAE_LY20-26P-DT1_2x13_P2.00mm_Vertical +Molex LY 20 series connector, LY20-26P-DT1, 13 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +26 +26 +Connector_JAE +JAE_LY20-28P-DLT1_2x14_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-28P-DLT1, 14 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +28 +28 +Connector_JAE +JAE_LY20-28P-DT1_2x14_P2.00mm_Vertical +Molex LY 20 series connector, LY20-28P-DT1, 14 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +28 +28 +Connector_JAE +JAE_LY20-30P-DLT1_2x15_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-30P-DLT1, 15 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +30 +30 +Connector_JAE +JAE_LY20-30P-DT1_2x15_P2.00mm_Vertical +Molex LY 20 series connector, LY20-30P-DT1, 15 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +30 +30 +Connector_JAE +JAE_LY20-32P-DLT1_2x16_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-32P-DLT1, 16 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +32 +32 +Connector_JAE +JAE_LY20-32P-DT1_2x16_P2.00mm_Vertical +Molex LY 20 series connector, LY20-32P-DT1, 16 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +32 +32 +Connector_JAE +JAE_LY20-34P-DLT1_2x17_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-34P-DLT1, 17 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +34 +34 +Connector_JAE +JAE_LY20-34P-DT1_2x17_P2.00mm_Vertical +Molex LY 20 series connector, LY20-34P-DT1, 17 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +34 +34 +Connector_JAE +JAE_LY20-36P-DLT1_2x18_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-36P-DLT1, 18 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +36 +36 +Connector_JAE +JAE_LY20-36P-DT1_2x18_P2.00mm_Vertical +Molex LY 20 series connector, LY20-36P-DT1, 18 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +36 +36 +Connector_JAE +JAE_LY20-38P-DLT1_2x19_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-38P-DLT1, 19 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +38 +38 +Connector_JAE +JAE_LY20-38P-DT1_2x19_P2.00mm_Vertical +Molex LY 20 series connector, LY20-38P-DT1, 19 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +38 +38 +Connector_JAE +JAE_LY20-40P-DLT1_2x20_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-40P-DLT1, 20 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +40 +40 +Connector_JAE +JAE_LY20-40P-DT1_2x20_P2.00mm_Vertical +Molex LY 20 series connector, LY20-40P-DT1, 20 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +40 +40 +Connector_JAE +JAE_LY20-42P-DLT1_2x21_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-42P-DLT1, 21 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +42 +42 +Connector_JAE +JAE_LY20-42P-DT1_2x21_P2.00mm_Vertical +Molex LY 20 series connector, LY20-42P-DT1, 21 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +42 +42 +Connector_JAE +JAE_LY20-44P-DLT1_2x22_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-44P-DLT1, 22 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +44 +44 +Connector_JAE +JAE_LY20-44P-DT1_2x22_P2.00mm_Vertical +Molex LY 20 series connector, LY20-44P-DT1, 22 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +44 +44 +Connector_JAE +JAE_MM70-314-310B1 +http://www.heilind.com/marketing/documents/jae/JAE_MM70.pdf +connector JAE MXM +0 +280 +279 +Connector_JAE +JAE_SIM_Card_SF72S006 +SIM Card, Push-Push, https://www.jae.com/direct/topics/topics_file_download/topics_id=68892&ext_no=06&index=0&_lang=en&v=202003111511468456809 +SIM Card with Detect Switch +0 +18 +9 +Connector_JST +JST_ACH_BM01B-ACHSS-A-GAN-ETF_1x01-1MP_P1.20mm_Vertical +JST ACH series connector, BM01B-ACHSS-A-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +3 +2 +Connector_JST +JST_ACH_BM02B-ACHSS-GAN-ETF_1x02-1MP_P1.20mm_Vertical +JST ACH series connector, BM02B-ACHSS-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +4 +3 +Connector_JST +JST_ACH_BM03B-ACHSS-GAN-ETF_1x03-1MP_P1.20mm_Vertical +JST ACH series connector, BM03B-ACHSS-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +5 +4 +Connector_JST +JST_ACH_BM04B-ACHSS-A-GAN-ETF_1x04-1MP_P1.20mm_Vertical +JST ACH series connector, BM04B-ACHSS-A-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +6 +5 +Connector_JST +JST_ACH_BM05B-ACHSS-A-GAN-ETF_1x05-1MP_P1.20mm_Vertical +JST ACH series connector, BM05B-ACHSS-A-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +7 +6 +Connector_JST +JST_AUH_BM03B-AUHKS-GA-TB_1x03-1MP_P1.50mm_Vertical +JST AUH series connector, BM03B-AUHKS-GA-TB (http://www.jst-mfg.com/product/pdf/eng/eAUH.pdf), generated with kicad-footprint-generator +connector JST AUH side entry +0 +5 +4 +Connector_JST +JST_AUH_BM05B-AUHKS-GA-TB_1x05-1MP_P1.50mm_Vertical +JST AUH series connector, BM05B-AUHKS-GA-TB (http://www.jst-mfg.com/product/pdf/eng/eAUH.pdf), generated with kicad-footprint-generator +connector JST AUH side entry +0 +7 +6 +Connector_JST +JST_EH_B2B-EH-A_1x02_P2.50mm_Vertical +JST EH series connector, B2B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +2 +2 +Connector_JST +JST_EH_B3B-EH-A_1x03_P2.50mm_Vertical +JST EH series connector, B3B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +3 +3 +Connector_JST +JST_EH_B4B-EH-A_1x04_P2.50mm_Vertical +JST EH series connector, B4B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +4 +4 +Connector_JST +JST_EH_B5B-EH-A_1x05_P2.50mm_Vertical +JST EH series connector, B5B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +5 +5 +Connector_JST +JST_EH_B6B-EH-A_1x06_P2.50mm_Vertical +JST EH series connector, B6B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +6 +6 +Connector_JST +JST_EH_B7B-EH-A_1x07_P2.50mm_Vertical +JST EH series connector, B7B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +7 +7 +Connector_JST +JST_EH_B8B-EH-A_1x08_P2.50mm_Vertical +JST EH series connector, B8B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +8 +8 +Connector_JST +JST_EH_B9B-EH-A_1x09_P2.50mm_Vertical +JST EH series connector, B9B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +9 +9 +Connector_JST +JST_EH_B10B-EH-A_1x10_P2.50mm_Vertical +JST EH series connector, B10B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +10 +10 +Connector_JST +JST_EH_B11B-EH-A_1x11_P2.50mm_Vertical +JST EH series connector, B11B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +11 +11 +Connector_JST +JST_EH_B12B-EH-A_1x12_P2.50mm_Vertical +JST EH series connector, B12B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +12 +12 +Connector_JST +JST_EH_B13B-EH-A_1x13_P2.50mm_Vertical +JST EH series connector, B13B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +13 +13 +Connector_JST +JST_EH_B14B-EH-A_1x14_P2.50mm_Vertical +JST EH series connector, B14B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +14 +14 +Connector_JST +JST_EH_B15B-EH-A_1x15_P2.50mm_Vertical +JST EH series connector, B15B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +15 +15 +Connector_JST +JST_EH_S2B-EH_1x02_P2.50mm_Horizontal +JST EH series connector, S2B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +2 +2 +Connector_JST +JST_EH_S3B-EH_1x03_P2.50mm_Horizontal +JST EH series connector, S3B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +3 +3 +Connector_JST +JST_EH_S4B-EH_1x04_P2.50mm_Horizontal +JST EH series connector, S4B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +4 +4 +Connector_JST +JST_EH_S5B-EH_1x05_P2.50mm_Horizontal +JST EH series connector, S5B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +5 +5 +Connector_JST +JST_EH_S6B-EH_1x06_P2.50mm_Horizontal +JST EH series connector, S6B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +6 +6 +Connector_JST +JST_EH_S7B-EH_1x07_P2.50mm_Horizontal +JST EH series connector, S7B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +7 +7 +Connector_JST +JST_EH_S8B-EH_1x08_P2.50mm_Horizontal +JST EH series connector, S8B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +8 +8 +Connector_JST +JST_EH_S9B-EH_1x09_P2.50mm_Horizontal +JST EH series connector, S9B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +9 +9 +Connector_JST +JST_EH_S10B-EH_1x10_P2.50mm_Horizontal +JST EH series connector, S10B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +10 +10 +Connector_JST +JST_EH_S11B-EH_1x11_P2.50mm_Horizontal +JST EH series connector, S11B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +11 +11 +Connector_JST +JST_EH_S12B-EH_1x12_P2.50mm_Horizontal +JST EH series connector, S12B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +12 +12 +Connector_JST +JST_EH_S13B-EH_1x13_P2.50mm_Horizontal +JST EH series connector, S13B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +13 +13 +Connector_JST +JST_EH_S14B-EH_1x14_P2.50mm_Horizontal +JST EH series connector, S14B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +14 +14 +Connector_JST +JST_EH_S15B-EH_1x15_P2.50mm_Horizontal +JST EH series connector, S15B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +15 +15 +Connector_JST +JST_GH_BM02B-GHS-TBT_1x02-1MP_P1.25mm_Vertical +JST GH series connector, BM02B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +4 +3 +Connector_JST +JST_GH_BM03B-GHS-TBT_1x03-1MP_P1.25mm_Vertical +JST GH series connector, BM03B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +5 +4 +Connector_JST +JST_GH_BM04B-GHS-TBT_1x04-1MP_P1.25mm_Vertical +JST GH series connector, BM04B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +6 +5 +Connector_JST +JST_GH_BM05B-GHS-TBT_1x05-1MP_P1.25mm_Vertical +JST GH series connector, BM05B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +7 +6 +Connector_JST +JST_GH_BM06B-GHS-TBT_1x06-1MP_P1.25mm_Vertical +JST GH series connector, BM06B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +8 +7 +Connector_JST +JST_GH_BM07B-GHS-TBT_1x07-1MP_P1.25mm_Vertical +JST GH series connector, BM07B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +9 +8 +Connector_JST +JST_GH_BM08B-GHS-TBT_1x08-1MP_P1.25mm_Vertical +JST GH series connector, BM08B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +10 +9 +Connector_JST +JST_GH_BM09B-GHS-TBT_1x09-1MP_P1.25mm_Vertical +JST GH series connector, BM09B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +11 +10 +Connector_JST +JST_GH_BM10B-GHS-TBT_1x10-1MP_P1.25mm_Vertical +JST GH series connector, BM10B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +12 +11 +Connector_JST +JST_GH_BM11B-GHS-TBT_1x11-1MP_P1.25mm_Vertical +JST GH series connector, BM11B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +13 +12 +Connector_JST +JST_GH_BM12B-GHS-TBT_1x12-1MP_P1.25mm_Vertical +JST GH series connector, BM12B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +14 +13 +Connector_JST +JST_GH_BM13B-GHS-TBT_1x13-1MP_P1.25mm_Vertical +JST GH series connector, BM13B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +15 +14 +Connector_JST +JST_GH_BM14B-GHS-TBT_1x14-1MP_P1.25mm_Vertical +JST GH series connector, BM14B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +16 +15 +Connector_JST +JST_GH_BM15B-GHS-TBT_1x15-1MP_P1.25mm_Vertical +JST GH series connector, BM15B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +17 +16 +Connector_JST +JST_GH_SM02B-GHS-TB_1x02-1MP_P1.25mm_Horizontal +JST GH series connector, SM02B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +4 +3 +Connector_JST +JST_GH_SM03B-GHS-TB_1x03-1MP_P1.25mm_Horizontal +JST GH series connector, SM03B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +5 +4 +Connector_JST +JST_GH_SM04B-GHS-TB_1x04-1MP_P1.25mm_Horizontal +JST GH series connector, SM04B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +6 +5 +Connector_JST +JST_GH_SM05B-GHS-TB_1x05-1MP_P1.25mm_Horizontal +JST GH series connector, SM05B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +7 +6 +Connector_JST +JST_GH_SM06B-GHS-TB_1x06-1MP_P1.25mm_Horizontal +JST GH series connector, SM06B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +8 +7 +Connector_JST +JST_GH_SM07B-GHS-TB_1x07-1MP_P1.25mm_Horizontal +JST GH series connector, SM07B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +9 +8 +Connector_JST +JST_GH_SM08B-GHS-TB_1x08-1MP_P1.25mm_Horizontal +JST GH series connector, SM08B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +10 +9 +Connector_JST +JST_GH_SM09B-GHS-TB_1x09-1MP_P1.25mm_Horizontal +JST GH series connector, SM09B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +11 +10 +Connector_JST +JST_GH_SM10B-GHS-TB_1x10-1MP_P1.25mm_Horizontal +JST GH series connector, SM10B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +12 +11 +Connector_JST +JST_GH_SM11B-GHS-TB_1x11-1MP_P1.25mm_Horizontal +JST GH series connector, SM11B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +13 +12 +Connector_JST +JST_GH_SM12B-GHS-TB_1x12-1MP_P1.25mm_Horizontal +JST GH series connector, SM12B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +14 +13 +Connector_JST +JST_GH_SM13B-GHS-TB_1x13-1MP_P1.25mm_Horizontal +JST GH series connector, SM13B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +15 +14 +Connector_JST +JST_GH_SM14B-GHS-TB_1x14-1MP_P1.25mm_Horizontal +JST GH series connector, SM14B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +16 +15 +Connector_JST +JST_GH_SM15B-GHS-TB_1x15-1MP_P1.25mm_Horizontal +JST GH series connector, SM15B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +17 +16 +Connector_JST +JST_J2100_B06B-J21DK-GGXR_2x03_P2.50x4.00mm_Vertical +JST J2100 series connector, B06B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +8 +6 +Connector_JST +JST_J2100_B08B-J21DK-GGXR_2x04_P2.50x4.00mm_Vertical +JST J2100 series connector, B08B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +10 +8 +Connector_JST +JST_J2100_B10B-J21DK-GGXR_2x05_P2.50x4.00mm_Vertical +JST J2100 series connector, B10B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +12 +10 +Connector_JST +JST_J2100_B12B-J21DK-GGXR_2x06_P2.50x4.00mm_Vertical +JST J2100 series connector, B12B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +14 +12 +Connector_JST +JST_J2100_B16B-J21DK-GGXR_2x08_P2.50x4.00mm_Vertical +JST J2100 series connector, B16B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +18 +16 +Connector_JST +JST_J2100_B20B-J21DK-GGXR_2x10_P2.50x4.00mm_Vertical +JST J2100 series connector, B20B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +22 +20 +Connector_JST +JST_J2100_S06B-J21DK-GGXR_2x03_P2.50mm_Horizontal +JST J2100 series connector, S06B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +7 +6 +Connector_JST +JST_J2100_S08B-J21DK-GGXR_2x04_P2.50mm_Horizontal +JST J2100 series connector, S08B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +10 +8 +Connector_JST +JST_J2100_S10B-J21DK-GGXR_2x05_P2.50mm_Horizontal +JST J2100 series connector, S10B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +12 +10 +Connector_JST +JST_J2100_S12B-J21DK-GGXR_2x06_P2.50mm_Horizontal +JST J2100 series connector, S12B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +14 +12 +Connector_JST +JST_J2100_S16B-J21DK-GGXR_2x08_P2.50mm_Horizontal +JST J2100 series connector, S16B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +18 +16 +Connector_JST +JST_J2100_S20B-J21DK-GGXR_2x10_P2.50mm_Horizontal +JST J2100 series connector, S20B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +22 +20 +Connector_JST +JST_JWPF_B02B-JWPF-SK-R_1x02_P2.00mm_Vertical +JST JWPF series connector, B02B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +2 +2 +Connector_JST +JST_JWPF_B03B-JWPF-SK-R_1x03_P2.00mm_Vertical +JST JWPF series connector, B03B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +3 +3 +Connector_JST +JST_JWPF_B04B-JWPF-SK-R_1x04_P2.00mm_Vertical +JST JWPF series connector, B04B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +4 +4 +Connector_JST +JST_JWPF_B06B-JWPF-SK-R_2x03_P2.00mm_Vertical +JST JWPF series connector, B06B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +6 +6 +Connector_JST +JST_JWPF_B08B-JWPF-SK-R_2x04_P2.00mm_Vertical +JST JWPF series connector, B08B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +8 +8 +Connector_JST +JST_LEA_SM02B-LEASS-TF_1x02-1MP_P4.20mm_Horizontal +JST LEA series connector, SM02B-LEASS-TF (http://www.jst-mfg.com/product/pdf/eng/eLEA.pdf), generated with kicad-footprint-generator +connector JST LEA top entry +0 +4 +3 +Connector_JST +JST_NV_B02P-NV_1x02_P5.00mm_Vertical +JST NV series connector, B02P-NV (http://www.jst-mfg.com/product/pdf/eng/eNV.pdf), generated with kicad-footprint-generator +connector JST NV side entry +0 +2 +2 +Connector_JST +JST_NV_B03P-NV_1x03_P5.00mm_Vertical +JST NV series connector, B03P-NV (http://www.jst-mfg.com/product/pdf/eng/eNV.pdf), generated with kicad-footprint-generator +connector JST NV side entry +0 +3 +3 +Connector_JST +JST_NV_B04P-NV_1x04_P5.00mm_Vertical +JST NV series connector, B04P-NV (http://www.jst-mfg.com/product/pdf/eng/eNV.pdf), generated with kicad-footprint-generator +connector JST NV side entry +0 +4 +4 +Connector_JST +JST_PHD_B8B-PHDSS_2x04_P2.00mm_Vertical +JST PHD series connector, B8B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +8 +8 +Connector_JST +JST_PHD_B10B-PHDSS_2x05_P2.00mm_Vertical +JST PHD series connector, B10B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +10 +10 +Connector_JST +JST_PHD_B12B-PHDSS_2x06_P2.00mm_Vertical +JST PHD series connector, B12B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +12 +12 +Connector_JST +JST_PHD_B14B-PHDSS_2x07_P2.00mm_Vertical +JST PHD series connector, B14B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +14 +14 +Connector_JST +JST_PHD_B16B-PHDSS_2x08_P2.00mm_Vertical +JST PHD series connector, B16B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +16 +16 +Connector_JST +JST_PHD_B18B-PHDSS_2x09_P2.00mm_Vertical +JST PHD series connector, B18B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +18 +18 +Connector_JST +JST_PHD_B20B-PHDSS_2x10_P2.00mm_Vertical +JST PHD series connector, B20B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +20 +20 +Connector_JST +JST_PHD_B22B-PHDSS_2x11_P2.00mm_Vertical +JST PHD series connector, B22B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +22 +22 +Connector_JST +JST_PHD_B24B-PHDSS_2x12_P2.00mm_Vertical +JST PHD series connector, B24B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +24 +24 +Connector_JST +JST_PHD_B26B-PHDSS_2x13_P2.00mm_Vertical +JST PHD series connector, B26B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +26 +26 +Connector_JST +JST_PHD_B28B-PHDSS_2x14_P2.00mm_Vertical +JST PHD series connector, B28B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +28 +28 +Connector_JST +JST_PHD_B30B-PHDSS_2x15_P2.00mm_Vertical +JST PHD series connector, B30B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +30 +30 +Connector_JST +JST_PHD_B32B-PHDSS_2x16_P2.00mm_Vertical +JST PHD series connector, B32B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +32 +32 +Connector_JST +JST_PHD_B34B-PHDSS_2x17_P2.00mm_Vertical +JST PHD series connector, B34B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +34 +34 +Connector_JST +JST_PHD_S8B-PHDSS_2x04_P2.00mm_Horizontal +JST PHD series connector, S8B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +8 +8 +Connector_JST +JST_PHD_S10B-PHDSS_2x05_P2.00mm_Horizontal +JST PHD series connector, S10B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +10 +10 +Connector_JST +JST_PHD_S12B-PHDSS_2x06_P2.00mm_Horizontal +JST PHD series connector, S12B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +12 +12 +Connector_JST +JST_PHD_S14B-PHDSS_2x07_P2.00mm_Horizontal +JST PHD series connector, S14B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +14 +14 +Connector_JST +JST_PHD_S16B-PHDSS_2x08_P2.00mm_Horizontal +JST PHD series connector, S16B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +16 +16 +Connector_JST +JST_PHD_S18B-PHDSS_2x09_P2.00mm_Horizontal +JST PHD series connector, S18B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +18 +18 +Connector_JST +JST_PHD_S20B-PHDSS_2x10_P2.00mm_Horizontal +JST PHD series connector, S20B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +20 +20 +Connector_JST +JST_PHD_S22B-PHDSS_2x11_P2.00mm_Horizontal +JST PHD series connector, S22B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +22 +22 +Connector_JST +JST_PHD_S24B-PHDSS_2x12_P2.00mm_Horizontal +JST PHD series connector, S24B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +24 +24 +Connector_JST +JST_PHD_S26B-PHDSS_2x13_P2.00mm_Horizontal +JST PHD series connector, S26B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +26 +26 +Connector_JST +JST_PHD_S28B-PHDSS_2x14_P2.00mm_Horizontal +JST PHD series connector, S28B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +28 +28 +Connector_JST +JST_PHD_S30B-PHDSS_2x15_P2.00mm_Horizontal +JST PHD series connector, S30B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +30 +30 +Connector_JST +JST_PHD_S32B-PHDSS_2x16_P2.00mm_Horizontal +JST PHD series connector, S32B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +32 +32 +Connector_JST +JST_PHD_S34B-PHDSS_2x17_P2.00mm_Horizontal +JST PHD series connector, S34B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +34 +34 +Connector_JST +JST_PH_B2B-PH-K_1x02_P2.00mm_Vertical +JST PH series connector, B2B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +2 +2 +Connector_JST +JST_PH_B2B-PH-SM4-TB_1x02-1MP_P2.00mm_Vertical +JST PH series connector, B2B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +4 +3 +Connector_JST +JST_PH_B3B-PH-K_1x03_P2.00mm_Vertical +JST PH series connector, B3B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +3 +3 +Connector_JST +JST_PH_B3B-PH-SM4-TB_1x03-1MP_P2.00mm_Vertical +JST PH series connector, B3B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +5 +4 +Connector_JST +JST_PH_B4B-PH-K_1x04_P2.00mm_Vertical +JST PH series connector, B4B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +4 +4 +Connector_JST +JST_PH_B4B-PH-SM4-TB_1x04-1MP_P2.00mm_Vertical +JST PH series connector, B4B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +6 +5 +Connector_JST +JST_PH_B5B-PH-K_1x05_P2.00mm_Vertical +JST PH series connector, B5B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +5 +5 +Connector_JST +JST_PH_B5B-PH-SM4-TB_1x05-1MP_P2.00mm_Vertical +JST PH series connector, B5B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +7 +6 +Connector_JST +JST_PH_B6B-PH-K_1x06_P2.00mm_Vertical +JST PH series connector, B6B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +6 +6 +Connector_JST +JST_PH_B6B-PH-SM4-TB_1x06-1MP_P2.00mm_Vertical +JST PH series connector, B6B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +8 +7 +Connector_JST +JST_PH_B7B-PH-K_1x07_P2.00mm_Vertical +JST PH series connector, B7B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +7 +7 +Connector_JST +JST_PH_B7B-PH-SM4-TB_1x07-1MP_P2.00mm_Vertical +JST PH series connector, B7B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +9 +8 +Connector_JST +JST_PH_B8B-PH-K_1x08_P2.00mm_Vertical +JST PH series connector, B8B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +8 +8 +Connector_JST +JST_PH_B8B-PH-SM4-TB_1x08-1MP_P2.00mm_Vertical +JST PH series connector, B8B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +10 +9 +Connector_JST +JST_PH_B9B-PH-K_1x09_P2.00mm_Vertical +JST PH series connector, B9B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +9 +9 +Connector_JST +JST_PH_B9B-PH-SM4-TB_1x09-1MP_P2.00mm_Vertical +JST PH series connector, B9B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +11 +10 +Connector_JST +JST_PH_B10B-PH-K_1x10_P2.00mm_Vertical +JST PH series connector, B10B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +10 +10 +Connector_JST +JST_PH_B10B-PH-SM4-TB_1x10-1MP_P2.00mm_Vertical +JST PH series connector, B10B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +12 +11 +Connector_JST +JST_PH_B11B-PH-K_1x11_P2.00mm_Vertical +JST PH series connector, B11B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +11 +11 +Connector_JST +JST_PH_B11B-PH-SM4-TB_1x11-1MP_P2.00mm_Vertical +JST PH series connector, B11B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +13 +12 +Connector_JST +JST_PH_B12B-PH-K_1x12_P2.00mm_Vertical +JST PH series connector, B12B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +12 +12 +Connector_JST +JST_PH_B12B-PH-SM4-TB_1x12-1MP_P2.00mm_Vertical +JST PH series connector, B12B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +14 +13 +Connector_JST +JST_PH_B13B-PH-K_1x13_P2.00mm_Vertical +JST PH series connector, B13B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +13 +13 +Connector_JST +JST_PH_B13B-PH-SM4-TB_1x13-1MP_P2.00mm_Vertical +JST PH series connector, B13B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +15 +14 +Connector_JST +JST_PH_B14B-PH-K_1x14_P2.00mm_Vertical +JST PH series connector, B14B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +14 +14 +Connector_JST +JST_PH_B14B-PH-SM4-TB_1x14-1MP_P2.00mm_Vertical +JST PH series connector, B14B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +16 +15 +Connector_JST +JST_PH_B15B-PH-K_1x15_P2.00mm_Vertical +JST PH series connector, B15B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +15 +15 +Connector_JST +JST_PH_B15B-PH-SM4-TB_1x15-1MP_P2.00mm_Vertical +JST PH series connector, B15B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +17 +16 +Connector_JST +JST_PH_B16B-PH-K_1x16_P2.00mm_Vertical +JST PH series connector, B16B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +16 +16 +Connector_JST +JST_PH_B16B-PH-SM4-TB_1x16-1MP_P2.00mm_Vertical +JST PH series connector, B16B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +18 +17 +Connector_JST +JST_PH_S2B-PH-K_1x02_P2.00mm_Horizontal +JST PH series connector, S2B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +2 +2 +Connector_JST +JST_PH_S2B-PH-SM4-TB_1x02-1MP_P2.00mm_Horizontal +JST PH series connector, S2B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +4 +3 +Connector_JST +JST_PH_S3B-PH-K_1x03_P2.00mm_Horizontal +JST PH series connector, S3B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +3 +3 +Connector_JST +JST_PH_S3B-PH-SM4-TB_1x03-1MP_P2.00mm_Horizontal +JST PH series connector, S3B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +5 +4 +Connector_JST +JST_PH_S4B-PH-K_1x04_P2.00mm_Horizontal +JST PH series connector, S4B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +4 +4 +Connector_JST +JST_PH_S4B-PH-SM4-TB_1x04-1MP_P2.00mm_Horizontal +JST PH series connector, S4B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +6 +5 +Connector_JST +JST_PH_S5B-PH-K_1x05_P2.00mm_Horizontal +JST PH series connector, S5B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +5 +5 +Connector_JST +JST_PH_S5B-PH-SM4-TB_1x05-1MP_P2.00mm_Horizontal +JST PH series connector, S5B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +7 +6 +Connector_JST +JST_PH_S6B-PH-K_1x06_P2.00mm_Horizontal +JST PH series connector, S6B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +6 +6 +Connector_JST +JST_PH_S6B-PH-SM4-TB_1x06-1MP_P2.00mm_Horizontal +JST PH series connector, S6B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +8 +7 +Connector_JST +JST_PH_S7B-PH-K_1x07_P2.00mm_Horizontal +JST PH series connector, S7B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +7 +7 +Connector_JST +JST_PH_S7B-PH-SM4-TB_1x07-1MP_P2.00mm_Horizontal +JST PH series connector, S7B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +9 +8 +Connector_JST +JST_PH_S8B-PH-K_1x08_P2.00mm_Horizontal +JST PH series connector, S8B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +8 +8 +Connector_JST +JST_PH_S8B-PH-SM4-TB_1x08-1MP_P2.00mm_Horizontal +JST PH series connector, S8B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +10 +9 +Connector_JST +JST_PH_S9B-PH-K_1x09_P2.00mm_Horizontal +JST PH series connector, S9B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +9 +9 +Connector_JST +JST_PH_S9B-PH-SM4-TB_1x09-1MP_P2.00mm_Horizontal +JST PH series connector, S9B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +11 +10 +Connector_JST +JST_PH_S10B-PH-K_1x10_P2.00mm_Horizontal +JST PH series connector, S10B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +10 +10 +Connector_JST +JST_PH_S10B-PH-SM4-TB_1x10-1MP_P2.00mm_Horizontal +JST PH series connector, S10B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +12 +11 +Connector_JST +JST_PH_S11B-PH-K_1x11_P2.00mm_Horizontal +JST PH series connector, S11B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +11 +11 +Connector_JST +JST_PH_S11B-PH-SM4-TB_1x11-1MP_P2.00mm_Horizontal +JST PH series connector, S11B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +13 +12 +Connector_JST +JST_PH_S12B-PH-K_1x12_P2.00mm_Horizontal +JST PH series connector, S12B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +12 +12 +Connector_JST +JST_PH_S12B-PH-SM4-TB_1x12-1MP_P2.00mm_Horizontal +JST PH series connector, S12B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +14 +13 +Connector_JST +JST_PH_S13B-PH-K_1x13_P2.00mm_Horizontal +JST PH series connector, S13B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +13 +13 +Connector_JST +JST_PH_S13B-PH-SM4-TB_1x13-1MP_P2.00mm_Horizontal +JST PH series connector, S13B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +15 +14 +Connector_JST +JST_PH_S14B-PH-K_1x14_P2.00mm_Horizontal +JST PH series connector, S14B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +14 +14 +Connector_JST +JST_PH_S14B-PH-SM4-TB_1x14-1MP_P2.00mm_Horizontal +JST PH series connector, S14B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +16 +15 +Connector_JST +JST_PH_S15B-PH-K_1x15_P2.00mm_Horizontal +JST PH series connector, S15B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +15 +15 +Connector_JST +JST_PH_S15B-PH-SM4-TB_1x15-1MP_P2.00mm_Horizontal +JST PH series connector, S15B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +17 +16 +Connector_JST +JST_PH_S16B-PH-K_1x16_P2.00mm_Horizontal +JST PH series connector, S16B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +16 +16 +Connector_JST +JST_PUD_B08B-PUDSS_2x04_P2.00mm_Vertical +JST PUD series connector, B08B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +8 +8 +Connector_JST +JST_PUD_B10B-PUDSS_2x05_P2.00mm_Vertical +JST PUD series connector, B10B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +10 +10 +Connector_JST +JST_PUD_B12B-PUDSS_2x06_P2.00mm_Vertical +JST PUD series connector, B12B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +12 +12 +Connector_JST +JST_PUD_B14B-PUDSS_2x07_P2.00mm_Vertical +JST PUD series connector, B14B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +14 +14 +Connector_JST +JST_PUD_B16B-PUDSS_2x08_P2.00mm_Vertical +JST PUD series connector, B16B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +16 +16 +Connector_JST +JST_PUD_B18B-PUDSS_2x09_P2.00mm_Vertical +JST PUD series connector, B18B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +18 +18 +Connector_JST +JST_PUD_B20B-PUDSS_2x10_P2.00mm_Vertical +JST PUD series connector, B20B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +20 +20 +Connector_JST +JST_PUD_B22B-PUDSS_2x11_P2.00mm_Vertical +JST PUD series connector, B22B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +22 +22 +Connector_JST +JST_PUD_B24B-PUDSS_2x12_P2.00mm_Vertical +JST PUD series connector, B24B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +24 +24 +Connector_JST +JST_PUD_B26B-PUDSS_2x13_P2.00mm_Vertical +JST PUD series connector, B26B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +26 +26 +Connector_JST +JST_PUD_B28B-PUDSS_2x14_P2.00mm_Vertical +JST PUD series connector, B28B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +28 +28 +Connector_JST +JST_PUD_B30B-PUDSS_2x15_P2.00mm_Vertical +JST PUD series connector, B30B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +30 +30 +Connector_JST +JST_PUD_B32B-PUDSS_2x16_P2.00mm_Vertical +JST PUD series connector, B32B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +32 +32 +Connector_JST +JST_PUD_B34B-PUDSS_2x17_P2.00mm_Vertical +JST PUD series connector, B34B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +34 +34 +Connector_JST +JST_PUD_B36B-PUDSS_2x18_P2.00mm_Vertical +JST PUD series connector, B36B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +36 +36 +Connector_JST +JST_PUD_B38B-PUDSS_2x19_P2.00mm_Vertical +JST PUD series connector, B38B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +38 +38 +Connector_JST +JST_PUD_B40B-PUDSS_2x20_P2.00mm_Vertical +JST PUD series connector, B40B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +40 +40 +Connector_JST +JST_PUD_S08B-PUDSS-1_2x04_P2.00mm_Horizontal +JST PUD series connector, S08B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +8 +8 +Connector_JST +JST_PUD_S10B-PUDSS-1_2x05_P2.00mm_Horizontal +JST PUD series connector, S10B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +10 +10 +Connector_JST +JST_PUD_S12B-PUDSS-1_2x06_P2.00mm_Horizontal +JST PUD series connector, S12B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +12 +12 +Connector_JST +JST_PUD_S14B-PUDSS-1_2x07_P2.00mm_Horizontal +JST PUD series connector, S14B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +14 +14 +Connector_JST +JST_PUD_S16B-PUDSS-1_2x08_P2.00mm_Horizontal +JST PUD series connector, S16B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +16 +16 +Connector_JST +JST_PUD_S18B-PUDSS-1_2x09_P2.00mm_Horizontal +JST PUD series connector, S18B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +18 +18 +Connector_JST +JST_PUD_S20B-PUDSS-1_2x10_P2.00mm_Horizontal +JST PUD series connector, S20B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +20 +20 +Connector_JST +JST_PUD_S22B-PUDSS-1_2x11_P2.00mm_Horizontal +JST PUD series connector, S22B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +22 +22 +Connector_JST +JST_PUD_S24B-PUDSS-1_2x12_P2.00mm_Horizontal +JST PUD series connector, S24B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +24 +24 +Connector_JST +JST_PUD_S26B-PUDSS-1_2x13_P2.00mm_Horizontal +JST PUD series connector, S26B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +26 +26 +Connector_JST +JST_PUD_S28B-PUDSS-1_2x14_P2.00mm_Horizontal +JST PUD series connector, S28B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +28 +28 +Connector_JST +JST_PUD_S30B-PUDSS-1_2x15_P2.00mm_Horizontal +JST PUD series connector, S30B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +30 +30 +Connector_JST +JST_PUD_S32B-PUDSS-1_2x16_P2.00mm_Horizontal +JST PUD series connector, S32B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +32 +32 +Connector_JST +JST_PUD_S34B-PUDSS-1_2x17_P2.00mm_Horizontal +JST PUD series connector, S34B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +34 +34 +Connector_JST +JST_PUD_S36B-PUDSS-1_2x18_P2.00mm_Horizontal +JST PUD series connector, S36B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +36 +36 +Connector_JST +JST_PUD_S38B-PUDSS-1_2x19_P2.00mm_Horizontal +JST PUD series connector, S38B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +38 +38 +Connector_JST +JST_PUD_S40B-PUDSS-1_2x20_P2.00mm_Horizontal +JST PUD series connector, S40B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +40 +40 +Connector_JST +JST_SFH_SM02B-SFHRS-TF_1x02-1MP_P4.20mm_Horizontal +JST SFH series connector, SM02B-SFHRS-TF (http://www.jst-mfg.com/product/pdf/eng/eSFH.pdf), generated with kicad-footprint-generator +connector JST SFH horizontal +0 +4 +3 +Connector_JST +JST_SHL_SM02B-SHLS-TF_1x02-1MP_P1.00mm_Horizontal +JST SHL series connector, SM02B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +4 +3 +Connector_JST +JST_SHL_SM05B-SHLS-TF_1x05-1MP_P1.00mm_Horizontal +JST SHL series connector, SM05B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +7 +6 +Connector_JST +JST_SHL_SM06B-SHLS-TF_1x06-1MP_P1.00mm_Horizontal +JST SHL series connector, SM06B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +8 +7 +Connector_JST +JST_SHL_SM07B-SHLS-TF_1x07-1MP_P1.00mm_Horizontal +JST SHL series connector, SM07B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +9 +8 +Connector_JST +JST_SHL_SM08B-SHLS-TF_1x08-1MP_P1.00mm_Horizontal +JST SHL series connector, SM08B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +10 +9 +Connector_JST +JST_SHL_SM10B-SHLS-TF_1x10-1MP_P1.00mm_Horizontal +JST SHL series connector, SM10B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +12 +11 +Connector_JST +JST_SHL_SM11B-SHLS-TF_1x11-1MP_P1.00mm_Horizontal +JST SHL series connector, SM11B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +13 +12 +Connector_JST +JST_SHL_SM12B-SHLS-TF_1x12-1MP_P1.00mm_Horizontal +JST SHL series connector, SM12B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +14 +13 +Connector_JST +JST_SHL_SM14B-SHLS-TF_1x14-1MP_P1.00mm_Horizontal +JST SHL series connector, SM14B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +16 +15 +Connector_JST +JST_SHL_SM16B-SHLS-TF_1x16-1MP_P1.00mm_Horizontal +JST SHL series connector, SM16B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +18 +17 +Connector_JST +JST_SHL_SM20B-SHLS-TF_1x20-1MP_P1.00mm_Horizontal +JST SHL series connector, SM20B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +22 +21 +Connector_JST +JST_SHL_SM22B-SHLS-TF_1x22-1MP_P1.00mm_Horizontal +JST SHL series connector, SM22B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +24 +23 +Connector_JST +JST_SHL_SM26B-SHLS-TF_1x26-1MP_P1.00mm_Horizontal +JST SHL series connector, SM26B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +28 +27 +Connector_JST +JST_SHL_SM30B-SHLS-TF_1x30-1MP_P1.00mm_Horizontal +JST SHL series connector, SM30B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +32 +31 +Connector_JST +JST_SH_BM02B-SRSS-TB_1x02-1MP_P1.00mm_Vertical +JST SH series connector, BM02B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +4 +3 +Connector_JST +JST_SH_BM03B-SRSS-TB_1x03-1MP_P1.00mm_Vertical +JST SH series connector, BM03B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +5 +4 +Connector_JST +JST_SH_BM04B-SRSS-TB_1x04-1MP_P1.00mm_Vertical +JST SH series connector, BM04B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +6 +5 +Connector_JST +JST_SH_BM05B-SRSS-TB_1x05-1MP_P1.00mm_Vertical +JST SH series connector, BM05B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +7 +6 +Connector_JST +JST_SH_BM06B-SRSS-TB_1x06-1MP_P1.00mm_Vertical +JST SH series connector, BM06B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +8 +7 +Connector_JST +JST_SH_BM07B-SRSS-TB_1x07-1MP_P1.00mm_Vertical +JST SH series connector, BM07B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +9 +8 +Connector_JST +JST_SH_BM08B-SRSS-TB_1x08-1MP_P1.00mm_Vertical +JST SH series connector, BM08B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +10 +9 +Connector_JST +JST_SH_BM09B-SRSS-TB_1x09-1MP_P1.00mm_Vertical +JST SH series connector, BM09B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +11 +10 +Connector_JST +JST_SH_BM10B-SRSS-TB_1x10-1MP_P1.00mm_Vertical +JST SH series connector, BM10B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +12 +11 +Connector_JST +JST_SH_BM11B-SRSS-TB_1x11-1MP_P1.00mm_Vertical +JST SH series connector, BM11B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +13 +12 +Connector_JST +JST_SH_BM12B-SRSS-TB_1x12-1MP_P1.00mm_Vertical +JST SH series connector, BM12B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +14 +13 +Connector_JST +JST_SH_BM13B-SRSS-TB_1x13-1MP_P1.00mm_Vertical +JST SH series connector, BM13B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +15 +14 +Connector_JST +JST_SH_BM14B-SRSS-TB_1x14-1MP_P1.00mm_Vertical +JST SH series connector, BM14B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +16 +15 +Connector_JST +JST_SH_BM15B-SRSS-TB_1x15-1MP_P1.00mm_Vertical +JST SH series connector, BM15B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +17 +16 +Connector_JST +JST_SH_SM02B-SRSS-TB_1x02-1MP_P1.00mm_Horizontal +JST SH series connector, SM02B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +4 +3 +Connector_JST +JST_SH_SM03B-SRSS-TB_1x03-1MP_P1.00mm_Horizontal +JST SH series connector, SM03B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +5 +4 +Connector_JST +JST_SH_SM04B-SRSS-TB_1x04-1MP_P1.00mm_Horizontal +JST SH series connector, SM04B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +6 +5 +Connector_JST +JST_SH_SM05B-SRSS-TB_1x05-1MP_P1.00mm_Horizontal +JST SH series connector, SM05B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +7 +6 +Connector_JST +JST_SH_SM06B-SRSS-TB_1x06-1MP_P1.00mm_Horizontal +JST SH series connector, SM06B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +8 +7 +Connector_JST +JST_SH_SM07B-SRSS-TB_1x07-1MP_P1.00mm_Horizontal +JST SH series connector, SM07B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +9 +8 +Connector_JST +JST_SH_SM08B-SRSS-TB_1x08-1MP_P1.00mm_Horizontal +JST SH series connector, SM08B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +10 +9 +Connector_JST +JST_SH_SM09B-SRSS-TB_1x09-1MP_P1.00mm_Horizontal +JST SH series connector, SM09B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +11 +10 +Connector_JST +JST_SH_SM10B-SRSS-TB_1x10-1MP_P1.00mm_Horizontal +JST SH series connector, SM10B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +12 +11 +Connector_JST +JST_SH_SM11B-SRSS-TB_1x11-1MP_P1.00mm_Horizontal +JST SH series connector, SM11B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +13 +12 +Connector_JST +JST_SH_SM12B-SRSS-TB_1x12-1MP_P1.00mm_Horizontal +JST SH series connector, SM12B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +14 +13 +Connector_JST +JST_SH_SM13B-SRSS-TB_1x13-1MP_P1.00mm_Horizontal +JST SH series connector, SM13B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +15 +14 +Connector_JST +JST_SH_SM14B-SRSS-TB_1x14-1MP_P1.00mm_Horizontal +JST SH series connector, SM14B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +16 +15 +Connector_JST +JST_SH_SM15B-SRSS-TB_1x15-1MP_P1.00mm_Horizontal +JST SH series connector, SM15B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +17 +16 +Connector_JST +JST_SH_SM20B-SRSS-TB_1x20-1MP_P1.00mm_Horizontal +JST SH series connector, SM20B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +22 +21 +Connector_JST +JST_SUR_BM02B-SURS-TF_1x02-1MP_P0.80mm_Vertical +JST SUR series connector, BM02B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +4 +3 +Connector_JST +JST_SUR_BM03B-SURS-TF_1x03-1MP_P0.80mm_Vertical +JST SUR series connector, BM03B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +5 +4 +Connector_JST +JST_SUR_BM04B-SURS-TF_1x04-1MP_P0.80mm_Vertical +JST SUR series connector, BM04B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +6 +5 +Connector_JST +JST_SUR_BM05B-SURS-TF_1x05-1MP_P0.80mm_Vertical +JST SUR series connector, BM05B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +7 +6 +Connector_JST +JST_SUR_BM06B-SURS-TF_1x06-1MP_P0.80mm_Vertical +JST SUR series connector, BM06B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +8 +7 +Connector_JST +JST_SUR_BM08B-SURS-TF_1x08-1MP_P0.80mm_Vertical +JST SUR series connector, BM08B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +10 +9 +Connector_JST +JST_SUR_BM10B-SURS-TF_1x10-1MP_P0.80mm_Vertical +JST SUR series connector, BM10B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +12 +11 +Connector_JST +JST_SUR_BM12B-SURS-TF_1x12-1MP_P0.80mm_Vertical +JST SUR series connector, BM12B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +14 +13 +Connector_JST +JST_SUR_BM14B-SURS-TF_1x14-1MP_P0.80mm_Vertical +JST SUR series connector, BM14B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +16 +15 +Connector_JST +JST_SUR_BM15B-SURS-TF_1x15-1MP_P0.80mm_Vertical +JST SUR series connector, BM15B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +17 +16 +Connector_JST +JST_SUR_BM16B-SURS-TF_1x16-1MP_P0.80mm_Vertical +JST SUR series connector, BM16B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +18 +17 +Connector_JST +JST_SUR_BM17B-SURS-TF_1x17-1MP_P0.80mm_Vertical +JST SUR series connector, BM17B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +19 +18 +Connector_JST +JST_SUR_BM20B-SURS-TF_1x20-1MP_P0.80mm_Vertical +JST SUR series connector, BM20B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +22 +21 +Connector_JST +JST_SUR_SM02B-SURS-TF_1x02-1MP_P0.80mm_Horizontal +JST SUR series connector, SM02B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +4 +3 +Connector_JST +JST_SUR_SM03B-SURS-TF_1x03-1MP_P0.80mm_Horizontal +JST SUR series connector, SM03B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +5 +4 +Connector_JST +JST_SUR_SM04B-SURS-TF_1x04-1MP_P0.80mm_Horizontal +JST SUR series connector, SM04B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +6 +5 +Connector_JST +JST_SUR_SM05B-SURS-TF_1x05-1MP_P0.80mm_Horizontal +JST SUR series connector, SM05B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +7 +6 +Connector_JST +JST_SUR_SM06B-SURS-TF_1x06-1MP_P0.80mm_Horizontal +JST SUR series connector, SM06B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +8 +7 +Connector_JST +JST_SUR_SM08B-SURS-TF_1x08-1MP_P0.80mm_Horizontal +JST SUR series connector, SM08B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +10 +9 +Connector_JST +JST_SUR_SM10B-SURS-TF_1x10-1MP_P0.80mm_Horizontal +JST SUR series connector, SM10B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +12 +11 +Connector_JST +JST_SUR_SM12B-SURS-TF_1x12-1MP_P0.80mm_Horizontal +JST SUR series connector, SM12B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +14 +13 +Connector_JST +JST_SUR_SM14B-SURS-TF_1x14-1MP_P0.80mm_Horizontal +JST SUR series connector, SM14B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +16 +15 +Connector_JST +JST_SUR_SM15B-SURS-TF_1x15-1MP_P0.80mm_Horizontal +JST SUR series connector, SM15B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +17 +16 +Connector_JST +JST_SUR_SM16B-SURS-TF_1x16-1MP_P0.80mm_Horizontal +JST SUR series connector, SM16B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +18 +17 +Connector_JST +JST_SUR_SM17B-SURS-TF_1x17-1MP_P0.80mm_Horizontal +JST SUR series connector, SM17B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +19 +18 +Connector_JST +JST_SUR_SM20B-SURS-TF_1x20-1MP_P0.80mm_Horizontal +JST SUR series connector, SM20B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +22 +21 +Connector_JST +JST_SUR_SM22B-SURS-TF_1x22-1MP_P0.80mm_Horizontal +JST SUR series connector, SM22B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +24 +23 +Connector_JST +JST_VH_B2P-VH-B_1x02_P3.96mm_Vertical +JST VH PBT series connector, B2P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +2 +2 +Connector_JST +JST_VH_B2P-VH-FB-B_1x02_P3.96mm_Vertical +JST VH series connector, B2P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +2 +2 +Connector_JST +JST_VH_B2P-VH_1x02_P3.96mm_Vertical +JST VH series connector, B2P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +2 +2 +Connector_JST +JST_VH_B2P3-VH_1x02_P7.92mm_Vertical +JST VH series connector, B2P3-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +2 +2 +Connector_JST +JST_VH_B2PS-VH_1x02_P3.96mm_Horizontal +JST VH series connector, B2PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +2 +2 +Connector_JST +JST_VH_B3P-VH-B_1x03_P3.96mm_Vertical +JST VH PBT series connector, B3P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +3 +3 +Connector_JST +JST_VH_B3P-VH-FB-B_1x03_P3.96mm_Vertical +JST VH series connector, B3P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +3 +3 +Connector_JST +JST_VH_B3P-VH_1x03_P3.96mm_Vertical +JST VH series connector, B3P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +3 +3 +Connector_JST +JST_VH_B3PS-VH_1x03_P3.96mm_Horizontal +JST VH series connector, B3PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +3 +3 +Connector_JST +JST_VH_B4P-VH-B_1x04_P3.96mm_Vertical +JST VH PBT series connector, B4P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +4 +4 +Connector_JST +JST_VH_B4P-VH-FB-B_1x04_P3.96mm_Vertical +JST VH series connector, B4P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +4 +4 +Connector_JST +JST_VH_B4P-VH_1x04_P3.96mm_Vertical +JST VH series connector, B4P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +4 +4 +Connector_JST +JST_VH_B4PS-VH_1x04_P3.96mm_Horizontal +JST VH series connector, B4PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +4 +4 +Connector_JST +JST_VH_B5P-VH-B_1x05_P3.96mm_Vertical +JST VH PBT series connector, B5P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +5 +5 +Connector_JST +JST_VH_B5P-VH-FB-B_1x05_P3.96mm_Vertical +JST VH series connector, B5P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +5 +5 +Connector_JST +JST_VH_B5P-VH_1x05_P3.96mm_Vertical +JST VH series connector, B5P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +5 +5 +Connector_JST +JST_VH_B5PS-VH_1x05_P3.96mm_Horizontal +JST VH series connector, B5PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +5 +5 +Connector_JST +JST_VH_B6P-VH-B_1x06_P3.96mm_Vertical +JST VH PBT series connector, B6P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +6 +6 +Connector_JST +JST_VH_B6P-VH-FB-B_1x06_P3.96mm_Vertical +JST VH series connector, B6P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +6 +6 +Connector_JST +JST_VH_B6P-VH_1x06_P3.96mm_Vertical +JST VH series connector, B6P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +6 +6 +Connector_JST +JST_VH_B6PS-VH_1x06_P3.96mm_Horizontal +JST VH series connector, B6PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +6 +6 +Connector_JST +JST_VH_B7P-VH-B_1x07_P3.96mm_Vertical +JST VH PBT series connector, B7P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +7 +7 +Connector_JST +JST_VH_B7P-VH-FB-B_1x07_P3.96mm_Vertical +JST VH series connector, B7P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +7 +7 +Connector_JST +JST_VH_B7P-VH_1x07_P3.96mm_Vertical +JST VH series connector, B7P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +7 +7 +Connector_JST +JST_VH_B7PS-VH_1x07_P3.96mm_Horizontal +JST VH series connector, B7PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +7 +7 +Connector_JST +JST_VH_B8P-VH-B_1x08_P3.96mm_Vertical +JST VH PBT series connector, B8P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +8 +8 +Connector_JST +JST_VH_B8P-VH-FB-B_1x08_P3.96mm_Vertical +JST VH series connector, B8P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +8 +8 +Connector_JST +JST_VH_B8P-VH_1x08_P3.96mm_Vertical +JST VH series connector, B8P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +8 +8 +Connector_JST +JST_VH_B8PS-VH_1x08_P3.96mm_Horizontal +JST VH series connector, B8PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +8 +8 +Connector_JST +JST_VH_B9P-VH-B_1x09_P3.96mm_Vertical +JST VH PBT series connector, B9P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +9 +9 +Connector_JST +JST_VH_B9P-VH-FB-B_1x09_P3.96mm_Vertical +JST VH series connector, B9P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +9 +9 +Connector_JST +JST_VH_B9P-VH_1x09_P3.96mm_Vertical +JST VH series connector, B9P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +9 +9 +Connector_JST +JST_VH_B9PS-VH_1x09_P3.96mm_Horizontal +JST VH series connector, B9PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +9 +9 +Connector_JST +JST_VH_B10P-VH-B_1x10_P3.96mm_Vertical +JST VH PBT series connector, B10P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +10 +10 +Connector_JST +JST_VH_B10P-VH-FB-B_1x10_P3.96mm_Vertical +JST VH series connector, B10P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +10 +10 +Connector_JST +JST_VH_B10P-VH_1x10_P3.96mm_Vertical +JST VH series connector, B10P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +10 +10 +Connector_JST +JST_VH_B10PS-VH_1x10_P3.96mm_Horizontal +JST VH series connector, B10PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +10 +10 +Connector_JST +JST_VH_B11P-VH-B_1x11_P3.96mm_Vertical +JST VH PBT series connector, B11P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +11 +11 +Connector_JST +JST_VH_S2P-VH_1x02_P3.96mm_Horizontal +JST VH series connector, S2P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +2 +2 +Connector_JST +JST_VH_S3P-VH_1x03_P3.96mm_Horizontal +JST VH series connector, S3P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +3 +3 +Connector_JST +JST_VH_S4P-VH_1x04_P3.96mm_Horizontal +JST VH series connector, S4P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +4 +4 +Connector_JST +JST_VH_S5P-VH_1x05_P3.96mm_Horizontal +JST VH series connector, S5P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +5 +5 +Connector_JST +JST_VH_S6P-VH_1x06_P3.96mm_Horizontal +JST VH series connector, S6P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +6 +6 +Connector_JST +JST_VH_S7P-VH_1x07_P3.96mm_Horizontal +JST VH series connector, S7P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +7 +7 +Connector_JST +JST_XAG_SM05B-XAGKS-BN-TB_1x05-1MP_P2.50mm_Horizontal +JST XAG series connector, SM05B-XAGKS-BN-TB (http://www.jst-mfg.com/product/pdf/eng/eXAG.pdf), generated with kicad-footprint-generator +connector JST XAG top entry +0 +7 +6 +Connector_JST +JST_XH_B1B-XH-AM_1x01_P2.50mm_Vertical +JST XH series connector, B1B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +1 +1 +Connector_JST +JST_XH_B2B-XH-AM_1x02_P2.50mm_Vertical +JST XH series connector, B2B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +2 +2 +Connector_JST +JST_XH_B2B-XH-A_1x02_P2.50mm_Vertical +JST XH series connector, B2B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +2 +2 +Connector_JST +JST_XH_B3B-XH-AM_1x03_P2.50mm_Vertical +JST XH series connector, B3B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +3 +3 +Connector_JST +JST_XH_B3B-XH-A_1x03_P2.50mm_Vertical +JST XH series connector, B3B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +3 +3 +Connector_JST +JST_XH_B4B-XH-AM_1x04_P2.50mm_Vertical +JST XH series connector, B4B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +4 +4 +Connector_JST +JST_XH_B4B-XH-A_1x04_P2.50mm_Vertical +JST XH series connector, B4B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +4 +4 +Connector_JST +JST_XH_B5B-XH-AM_1x05_P2.50mm_Vertical +JST XH series connector, B5B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +5 +5 +Connector_JST +JST_XH_B5B-XH-A_1x05_P2.50mm_Vertical +JST XH series connector, B5B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +5 +5 +Connector_JST +JST_XH_B6B-XH-AM_1x06_P2.50mm_Vertical +JST XH series connector, B6B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +6 +6 +Connector_JST +JST_XH_B6B-XH-A_1x06_P2.50mm_Vertical +JST XH series connector, B6B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +6 +6 +Connector_JST +JST_XH_B7B-XH-AM_1x07_P2.50mm_Vertical +JST XH series connector, B7B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +7 +7 +Connector_JST +JST_XH_B7B-XH-A_1x07_P2.50mm_Vertical +JST XH series connector, B7B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +7 +7 +Connector_JST +JST_XH_B8B-XH-AM_1x08_P2.50mm_Vertical +JST XH series connector, B8B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +8 +8 +Connector_JST +JST_XH_B8B-XH-A_1x08_P2.50mm_Vertical +JST XH series connector, B8B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +8 +8 +Connector_JST +JST_XH_B9B-XH-AM_1x09_P2.50mm_Vertical +JST XH series connector, B9B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +9 +9 +Connector_JST +JST_XH_B9B-XH-A_1x09_P2.50mm_Vertical +JST XH series connector, B9B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +9 +9 +Connector_JST +JST_XH_B10B-XH-AM_1x10_P2.50mm_Vertical +JST XH series connector, B10B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry boss +0 +10 +10 +Connector_JST +JST_XH_B10B-XH-A_1x10_P2.50mm_Vertical +JST XH series connector, B10B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +10 +10 +Connector_JST +JST_XH_B11B-XH-A_1x11_P2.50mm_Vertical +JST XH series connector, B11B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +11 +11 +Connector_JST +JST_XH_B12B-XH-AM_1x12_P2.50mm_Vertical +JST XH series connector, B12B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry boss +0 +12 +12 +Connector_JST +JST_XH_B12B-XH-A_1x12_P2.50mm_Vertical +JST XH series connector, B12B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +12 +12 +Connector_JST +JST_XH_B13B-XH-A_1x13_P2.50mm_Vertical +JST XH series connector, B13B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +13 +13 +Connector_JST +JST_XH_B14B-XH-A_1x14_P2.50mm_Vertical +JST XH series connector, B14B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +14 +14 +Connector_JST +JST_XH_B15B-XH-A_1x15_P2.50mm_Vertical +JST XH series connector, B15B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +15 +15 +Connector_JST +JST_XH_B16B-XH-A_1x16_P2.50mm_Vertical +JST XH series connector, B16B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +16 +16 +Connector_JST +JST_XH_B20B-XH-A_1x20_P2.50mm_Vertical +JST XH series connector, B20B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +20 +20 +Connector_JST +JST_XH_S2B-XH-A-1_1x02_P2.50mm_Horizontal +JST XH series connector, S2B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +2 +2 +Connector_JST +JST_XH_S2B-XH-A_1x02_P2.50mm_Horizontal +JST XH series connector, S2B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +2 +2 +Connector_JST +JST_XH_S3B-XH-A-1_1x03_P2.50mm_Horizontal +JST XH series connector, S3B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +3 +3 +Connector_JST +JST_XH_S3B-XH-A_1x03_P2.50mm_Horizontal +JST XH series connector, S3B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +3 +3 +Connector_JST +JST_XH_S4B-XH-A-1_1x04_P2.50mm_Horizontal +JST XH series connector, S4B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +4 +4 +Connector_JST +JST_XH_S4B-XH-A_1x04_P2.50mm_Horizontal +JST XH series connector, S4B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +4 +4 +Connector_JST +JST_XH_S5B-XH-A-1_1x05_P2.50mm_Horizontal +JST XH series connector, S5B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +5 +5 +Connector_JST +JST_XH_S5B-XH-A_1x05_P2.50mm_Horizontal +JST XH series connector, S5B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +5 +5 +Connector_JST +JST_XH_S6B-XH-A-1_1x06_P2.50mm_Horizontal +JST XH series connector, S6B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +6 +6 +Connector_JST +JST_XH_S6B-XH-A_1x06_P2.50mm_Horizontal +JST XH series connector, S6B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +6 +6 +Connector_JST +JST_XH_S7B-XH-A-1_1x07_P2.50mm_Horizontal +JST XH series connector, S7B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +7 +7 +Connector_JST +JST_XH_S7B-XH-A_1x07_P2.50mm_Horizontal +JST XH series connector, S7B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +7 +7 +Connector_JST +JST_XH_S8B-XH-A-1_1x08_P2.50mm_Horizontal +JST XH series connector, S8B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +8 +8 +Connector_JST +JST_XH_S8B-XH-A_1x08_P2.50mm_Horizontal +JST XH series connector, S8B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +8 +8 +Connector_JST +JST_XH_S9B-XH-A-1_1x09_P2.50mm_Horizontal +JST XH series connector, S9B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +9 +9 +Connector_JST +JST_XH_S9B-XH-A_1x09_P2.50mm_Horizontal +JST XH series connector, S9B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +9 +9 +Connector_JST +JST_XH_S10B-XH-A-1_1x10_P2.50mm_Horizontal +JST XH series connector, S10B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +10 +10 +Connector_JST +JST_XH_S10B-XH-A_1x10_P2.50mm_Horizontal +JST XH series connector, S10B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +10 +10 +Connector_JST +JST_XH_S11B-XH-A-1_1x11_P2.50mm_Horizontal +JST XH series connector, S11B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +11 +11 +Connector_JST +JST_XH_S11B-XH-A_1x11_P2.50mm_Horizontal +JST XH series connector, S11B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +11 +11 +Connector_JST +JST_XH_S12B-XH-A-1_1x12_P2.50mm_Horizontal +JST XH series connector, S12B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +12 +12 +Connector_JST +JST_XH_S12B-XH-A_1x12_P2.50mm_Horizontal +JST XH series connector, S12B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +12 +12 +Connector_JST +JST_XH_S13B-XH-A-1_1x13_P2.50mm_Horizontal +JST XH series connector, S13B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +13 +13 +Connector_JST +JST_XH_S13B-XH-A_1x13_P2.50mm_Horizontal +JST XH series connector, S13B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +13 +13 +Connector_JST +JST_XH_S14B-XH-A-1_1x14_P2.50mm_Horizontal +JST XH series connector, S14B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +14 +14 +Connector_JST +JST_XH_S14B-XH-A_1x14_P2.50mm_Horizontal +JST XH series connector, S14B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +14 +14 +Connector_JST +JST_XH_S15B-XH-A-1_1x15_P2.50mm_Horizontal +JST XH series connector, S15B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +15 +15 +Connector_JST +JST_XH_S15B-XH-A_1x15_P2.50mm_Horizontal +JST XH series connector, S15B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +15 +15 +Connector_JST +JST_XH_S16B-XH-A_1x16_P2.50mm_Horizontal +JST XH series connector, S16B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +16 +16 +Connector_JST +JST_ZE_B02B-ZESK-1D_1x02_P1.50mm_Vertical +JST ZE series connector, B02B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +2 +2 +Connector_JST +JST_ZE_B03B-ZESK-1D_1x03_P1.50mm_Vertical +JST ZE series connector, B03B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +3 +3 +Connector_JST +JST_ZE_B03B-ZESK-D_1x03_P1.50mm_Vertical +JST ZE series connector, B03B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +3 +3 +Connector_JST +JST_ZE_B04B-ZESK-1D_1x04_P1.50mm_Vertical +JST ZE series connector, B04B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +4 +4 +Connector_JST +JST_ZE_B04B-ZESK-D_1x04_P1.50mm_Vertical +JST ZE series connector, B04B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +4 +4 +Connector_JST +JST_ZE_B05B-ZESK-1D_1x05_P1.50mm_Vertical +JST ZE series connector, B05B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +5 +5 +Connector_JST +JST_ZE_B05B-ZESK-D_1x05_P1.50mm_Vertical +JST ZE series connector, B05B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +5 +5 +Connector_JST +JST_ZE_B06B-ZESK-1D_1x06_P1.50mm_Vertical +JST ZE series connector, B06B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +6 +6 +Connector_JST +JST_ZE_B06B-ZESK-D_1x06_P1.50mm_Vertical +JST ZE series connector, B06B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +6 +6 +Connector_JST +JST_ZE_B07B-ZESK-1D_1x07_P1.50mm_Vertical +JST ZE series connector, B07B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +7 +7 +Connector_JST +JST_ZE_B07B-ZESK-D_1x07_P1.50mm_Vertical +JST ZE series connector, B07B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +7 +7 +Connector_JST +JST_ZE_B08B-ZESK-1D_1x08_P1.50mm_Vertical +JST ZE series connector, B08B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +8 +8 +Connector_JST +JST_ZE_B08B-ZESK-D_1x08_P1.50mm_Vertical +JST ZE series connector, B08B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +8 +8 +Connector_JST +JST_ZE_B09B-ZESK-1D_1x09_P1.50mm_Vertical +JST ZE series connector, B09B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +9 +9 +Connector_JST +JST_ZE_B09B-ZESK-D_1x09_P1.50mm_Vertical +JST ZE series connector, B09B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +9 +9 +Connector_JST +JST_ZE_B10B-ZESK-1D_1x10_P1.50mm_Vertical +JST ZE series connector, B10B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +10 +10 +Connector_JST +JST_ZE_B10B-ZESK-D_1x10_P1.50mm_Vertical +JST ZE series connector, B10B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +10 +10 +Connector_JST +JST_ZE_B11B-ZESK-1D_1x11_P1.50mm_Vertical +JST ZE series connector, B11B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +11 +11 +Connector_JST +JST_ZE_B11B-ZESK-D_1x11_P1.50mm_Vertical +JST ZE series connector, B11B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +11 +11 +Connector_JST +JST_ZE_B12B-ZESK-1D_1x12_P1.50mm_Vertical +JST ZE series connector, B12B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +12 +12 +Connector_JST +JST_ZE_B12B-ZESK-D_1x12_P1.50mm_Vertical +JST ZE series connector, B12B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +12 +12 +Connector_JST +JST_ZE_B13B-ZESK-1D_1x13_P1.50mm_Vertical +JST ZE series connector, B13B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +13 +13 +Connector_JST +JST_ZE_B13B-ZESK-D_1x13_P1.50mm_Vertical +JST ZE series connector, B13B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +13 +13 +Connector_JST +JST_ZE_B14B-ZESK-1D_1x14_P1.50mm_Vertical +JST ZE series connector, B14B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +14 +14 +Connector_JST +JST_ZE_B14B-ZESK-D_1x14_P1.50mm_Vertical +JST ZE series connector, B14B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +14 +14 +Connector_JST +JST_ZE_B15B-ZESK-1D_1x15_P1.50mm_Vertical +JST ZE series connector, B15B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +15 +15 +Connector_JST +JST_ZE_B15B-ZESK-D_1x15_P1.50mm_Vertical +JST ZE series connector, B15B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +15 +15 +Connector_JST +JST_ZE_B16B-ZESK-1D_1x16_P1.50mm_Vertical +JST ZE series connector, B16B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +16 +16 +Connector_JST +JST_ZE_B16B-ZESK-D_1x16_P1.50mm_Vertical +JST ZE series connector, B16B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +16 +16 +Connector_JST +JST_ZE_BM02B-ZESS-TBT_1x02-1MP_P1.50mm_Vertical +JST ZE series connector, BM02B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +4 +3 +Connector_JST +JST_ZE_BM03B-ZESS-TBT_1x03-1MP_P1.50mm_Vertical +JST ZE series connector, BM03B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +5 +4 +Connector_JST +JST_ZE_BM04B-ZESS-TBT_1x04-1MP_P1.50mm_Vertical +JST ZE series connector, BM04B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +6 +5 +Connector_JST +JST_ZE_BM05B-ZESS-TBT_1x05-1MP_P1.50mm_Vertical +JST ZE series connector, BM05B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +7 +6 +Connector_JST +JST_ZE_BM06B-ZESS-TBT_1x06-1MP_P1.50mm_Vertical +JST ZE series connector, BM06B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +8 +7 +Connector_JST +JST_ZE_BM07B-ZESS-TBT_1x07-1MP_P1.50mm_Vertical +JST ZE series connector, BM07B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +9 +8 +Connector_JST +JST_ZE_BM08B-ZESS-TBT_1x08-1MP_P1.50mm_Vertical +JST ZE series connector, BM08B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +10 +9 +Connector_JST +JST_ZE_BM09B-ZESS-TBT_1x09-1MP_P1.50mm_Vertical +JST ZE series connector, BM09B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +11 +10 +Connector_JST +JST_ZE_BM10B-ZESS-TBT_1x10-1MP_P1.50mm_Vertical +JST ZE series connector, BM10B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +12 +11 +Connector_JST +JST_ZE_BM11B-ZESS-TBT_1x11-1MP_P1.50mm_Vertical +JST ZE series connector, BM11B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +13 +12 +Connector_JST +JST_ZE_BM12B-ZESS-TBT_1x12-1MP_P1.50mm_Vertical +JST ZE series connector, BM12B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +14 +13 +Connector_JST +JST_ZE_BM13B-ZESS-TBT_1x13-1MP_P1.50mm_Vertical +JST ZE series connector, BM13B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +15 +14 +Connector_JST +JST_ZE_BM14B-ZESS-TBT_1x14-1MP_P1.50mm_Vertical +JST ZE series connector, BM14B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +16 +15 +Connector_JST +JST_ZE_BM15B-ZESS-TBT_1x15-1MP_P1.50mm_Vertical +JST ZE series connector, BM15B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +17 +16 +Connector_JST +JST_ZE_BM16B-ZESS-TBT_1x16-1MP_P1.50mm_Vertical +JST ZE series connector, BM16B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +18 +17 +Connector_JST +JST_ZE_S02B-ZESK-2D_1x02_P1.50mm_Horizontal +JST ZE series connector, S02B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +2 +2 +Connector_JST +JST_ZE_S03B-ZESK-2D_1x03_P1.50mm_Horizontal +JST ZE series connector, S03B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +3 +3 +Connector_JST +JST_ZE_S04B-ZESK-2D_1x04_P1.50mm_Horizontal +JST ZE series connector, S04B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +4 +4 +Connector_JST +JST_ZE_S05B-ZESK-2D_1x05_P1.50mm_Horizontal +JST ZE series connector, S05B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +5 +5 +Connector_JST +JST_ZE_S06B-ZESK-2D_1x06_P1.50mm_Horizontal +JST ZE series connector, S06B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +6 +6 +Connector_JST +JST_ZE_S07B-ZESK-2D_1x07_P1.50mm_Horizontal +JST ZE series connector, S07B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +7 +7 +Connector_JST +JST_ZE_S08B-ZESK-2D_1x08_P1.50mm_Horizontal +JST ZE series connector, S08B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +8 +8 +Connector_JST +JST_ZE_S09B-ZESK-2D_1x09_P1.50mm_Horizontal +JST ZE series connector, S09B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +9 +9 +Connector_JST +JST_ZE_S10B-ZESK-2D_1x10_P1.50mm_Horizontal +JST ZE series connector, S10B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +10 +10 +Connector_JST +JST_ZE_S11B-ZESK-2D_1x11_P1.50mm_Horizontal +JST ZE series connector, S11B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +11 +11 +Connector_JST +JST_ZE_S12B-ZESK-2D_1x12_P1.50mm_Horizontal +JST ZE series connector, S12B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +12 +12 +Connector_JST +JST_ZE_S13B-ZESK-2D_1x13_P1.50mm_Horizontal +JST ZE series connector, S13B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +13 +13 +Connector_JST +JST_ZE_S14B-ZESK-2D_1x14_P1.50mm_Horizontal +JST ZE series connector, S14B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +14 +14 +Connector_JST +JST_ZE_S15B-ZESK-2D_1x15_P1.50mm_Horizontal +JST ZE series connector, S15B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +15 +15 +Connector_JST +JST_ZE_S16B-ZESK-2D_1x16_P1.50mm_Horizontal +JST ZE series connector, S16B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +16 +16 +Connector_JST +JST_ZE_SM02B-ZESS-TB_1x02-1MP_P1.50mm_Horizontal +JST ZE series connector, SM02B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +4 +3 +Connector_JST +JST_ZE_SM03B-ZESS-TB_1x03-1MP_P1.50mm_Horizontal +JST ZE series connector, SM03B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +5 +4 +Connector_JST +JST_ZE_SM04B-ZESS-TB_1x04-1MP_P1.50mm_Horizontal +JST ZE series connector, SM04B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +6 +5 +Connector_JST +JST_ZE_SM05B-ZESS-TB_1x05-1MP_P1.50mm_Horizontal +JST ZE series connector, SM05B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +7 +6 +Connector_JST +JST_ZE_SM06B-ZESS-TB_1x06-1MP_P1.50mm_Horizontal +JST ZE series connector, SM06B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +8 +7 +Connector_JST +JST_ZE_SM07B-ZESS-TB_1x07-1MP_P1.50mm_Horizontal +JST ZE series connector, SM07B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +9 +8 +Connector_JST +JST_ZE_SM08B-ZESS-TB_1x08-1MP_P1.50mm_Horizontal +JST ZE series connector, SM08B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +10 +9 +Connector_JST +JST_ZE_SM09B-ZESS-TB_1x09-1MP_P1.50mm_Horizontal +JST ZE series connector, SM09B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +11 +10 +Connector_JST +JST_ZE_SM10B-ZESS-TB_1x10-1MP_P1.50mm_Horizontal +JST ZE series connector, SM10B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +12 +11 +Connector_JST +JST_ZE_SM11B-ZESS-TB_1x11-1MP_P1.50mm_Horizontal +JST ZE series connector, SM11B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +13 +12 +Connector_JST +JST_ZE_SM12B-ZESS-TB_1x12-1MP_P1.50mm_Horizontal +JST ZE series connector, SM12B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +14 +13 +Connector_JST +JST_ZE_SM13B-ZESS-TB_1x13-1MP_P1.50mm_Horizontal +JST ZE series connector, SM13B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +15 +14 +Connector_JST +JST_ZE_SM14B-ZESS-TB_1x14-1MP_P1.50mm_Horizontal +JST ZE series connector, SM14B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +16 +15 +Connector_JST +JST_ZE_SM15B-ZESS-TB_1x15-1MP_P1.50mm_Horizontal +JST ZE series connector, SM15B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +17 +16 +Connector_JST +JST_ZE_SM16B-ZESS-TB_1x16-1MP_P1.50mm_Horizontal +JST ZE series connector, SM16B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +18 +17 +Connector_Molex +Molex_CLIK-Mate_502382-0270_1x02-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0270 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502382-0370_1x03-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0370 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502382-0470_1x04-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0470 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502382-0570_1x05-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0570 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502382-0670_1x06-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0670 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502382-0770_1x07-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0770 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502382-0870_1x08-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0870 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502382-0970_1x09-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0970 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502382-1070_1x10-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1070 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502382-1170_1x11-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1170 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_502382-1270_1x12-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1270 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502382-1370_1x13-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1370 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502382-1470_1x14-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1470 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502382-1570_1x15-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1570 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502386-0270_1x02-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0270 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502386-0370_1x03-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0370 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502386-0470_1x04-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0470 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502386-0570_1x05-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0570 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502386-0670_1x06-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0670 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502386-0770_1x07-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0770 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502386-0870_1x08-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0870 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502386-0970_1x09-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0970 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502386-1070_1x10-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1070 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502386-1170_1x11-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1170 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_502386-1270_1x12-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1270 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502386-1370_1x13-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1370 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502386-1470_1x14-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1470 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502386-1570_1x15-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1570 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502443-0270_1x02-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0270 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502443-0370_1x03-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0370 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502443-0470_1x04-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0470 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502443-0570_1x05-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0570 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502443-0670_1x06-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0670 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502443-0770_1x07-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0770 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502443-0870_1x08-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0870 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502443-0970_1x09-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0970 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502443-1270_1x12-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1270 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502443-1370_1x13-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1370 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502443-1470_1x14-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1470 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502443-1570_1x15-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1570 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502494-0270_1x02-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0270 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502494-0370_1x03-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0370 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502494-0470_1x04-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0470 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502494-0670_1x06-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0670 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502494-0870_1x08-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0870 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502494-1070_1x10-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1070 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502494-1270_1x12-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1270 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502494-1370_1x13-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1370 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502494-1470_1x14-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1470 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502494-1570_1x15-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1570 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502585-0270_1x02-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0270 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502585-0370_1x03-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0370 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502585-0470_1x04-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0470 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502585-0570_1x05-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0570 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502585-0670_1x06-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0670 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502585-0770_1x07-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0770 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502585-0870_1x08-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0870 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502585-0970_1x09-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0970 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502585-1070_1x10-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1070 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502585-1170_1x11-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1170 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_502585-1270_1x12-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1270 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502585-1370_1x13-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1370 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502585-1470_1x14-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1470 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502585-1570_1x15-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1570 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_505405-0270_1x02-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0270 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_505405-0370_1x03-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0370 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_505405-0470_1x04-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0470 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_505405-0570_1x05-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0570 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_505405-0670_1x06-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0670 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_505405-0770_1x07-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0770 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_505405-0870_1x08-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0870 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_505405-0970_1x09-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0970 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_505405-1070_1x10-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1070 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_505405-1170_1x11-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1170 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_505405-1270_1x12-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1270 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_505405-1370_1x13-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1370 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_505405-1470_1x14-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1470 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_505405-1570_1x15-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1570 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +17 +16 +Connector_Molex +Molex_KK-254_AE-6410-02A_1x02_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-02A example for new part number: 22-27-2021, 2 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +2 +2 +Connector_Molex +Molex_KK-254_AE-6410-03A_1x03_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-03A example for new part number: 22-27-2031, 3 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +3 +3 +Connector_Molex +Molex_KK-254_AE-6410-04A_1x04_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-04A example for new part number: 22-27-2041, 4 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +4 +4 +Connector_Molex +Molex_KK-254_AE-6410-05A_1x05_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-05A example for new part number: 22-27-2051, 5 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +5 +5 +Connector_Molex +Molex_KK-254_AE-6410-06A_1x06_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-06A example for new part number: 22-27-2061, 6 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +6 +6 +Connector_Molex +Molex_KK-254_AE-6410-07A_1x07_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-07A example for new part number: 22-27-2071, 7 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +7 +7 +Connector_Molex +Molex_KK-254_AE-6410-08A_1x08_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-08A example for new part number: 22-27-2081, 8 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +8 +8 +Connector_Molex +Molex_KK-254_AE-6410-09A_1x09_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-09A example for new part number: 22-27-2091, 9 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +9 +9 +Connector_Molex +Molex_KK-254_AE-6410-10A_1x10_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-10A example for new part number: 22-27-2101, 10 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +10 +10 +Connector_Molex +Molex_KK-254_AE-6410-11A_1x11_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-11A example for new part number: 22-27-2111, 11 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +11 +11 +Connector_Molex +Molex_KK-254_AE-6410-12A_1x12_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-12A example for new part number: 22-27-2121, 12 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +12 +12 +Connector_Molex +Molex_KK-254_AE-6410-13A_1x13_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-13A example for new part number: 22-27-2131, 13 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +13 +13 +Connector_Molex +Molex_KK-254_AE-6410-14A_1x14_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-14A example for new part number: 22-27-2141, 14 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +14 +14 +Connector_Molex +Molex_KK-254_AE-6410-15A_1x15_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-15A example for new part number: 22-27-2151, 15 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +15 +15 +Connector_Molex +Molex_KK-254_AE-6410-16A_1x16_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-16A example for new part number: 22-27-2161, 16 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +16 +16 +Connector_Molex +Molex_KK-396_A-41791-0002_1x02_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0002 example for new part number: 26-60-4020, 2 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +2 +2 +Connector_Molex +Molex_KK-396_A-41791-0003_1x03_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0003 example for new part number: 26-60-4030, 3 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +3 +3 +Connector_Molex +Molex_KK-396_A-41791-0004_1x04_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0004 example for new part number: 26-60-4040, 4 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +4 +4 +Connector_Molex +Molex_KK-396_A-41791-0005_1x05_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0005 example for new part number: 26-60-4050, 5 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +5 +5 +Connector_Molex +Molex_KK-396_A-41791-0006_1x06_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0006 example for new part number: 26-60-4060, 6 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +6 +6 +Connector_Molex +Molex_KK-396_A-41791-0007_1x07_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0007 example for new part number: 26-60-4070, 7 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +7 +7 +Connector_Molex +Molex_KK-396_A-41791-0008_1x08_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0008 example for new part number: 26-60-4080, 8 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +8 +8 +Connector_Molex +Molex_KK-396_A-41791-0009_1x09_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0009 example for new part number: 26-60-4090, 9 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +9 +9 +Connector_Molex +Molex_KK-396_A-41791-0010_1x10_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0010 example for new part number: 26-60-4100, 10 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +10 +10 +Connector_Molex +Molex_KK-396_A-41791-0011_1x11_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0011 example for new part number: 26-60-4110, 11 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +11 +11 +Connector_Molex +Molex_KK-396_A-41791-0012_1x12_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0012 example for new part number: 26-60-4120, 12 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +12 +12 +Connector_Molex +Molex_KK-396_A-41791-0013_1x13_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0013 example for new part number: 26-60-4130, 13 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +13 +13 +Connector_Molex +Molex_KK-396_A-41791-0014_1x14_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0014 example for new part number: 26-60-4140, 14 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +14 +14 +Connector_Molex +Molex_KK-396_A-41791-0015_1x15_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0015 example for new part number: 26-60-4150, 15 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +15 +15 +Connector_Molex +Molex_KK-396_A-41791-0016_1x16_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0016 example for new part number: 26-60-4160, 16 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +16 +16 +Connector_Molex +Molex_KK-396_A-41791-0017_1x17_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0017 example for new part number: 26-60-4170, 17 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +17 +17 +Connector_Molex +Molex_KK-396_A-41791-0018_1x18_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0018 example for new part number: 26-60-4180, 18 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +18 +18 +Connector_Molex +Molex_Mega-Fit_76825-0002_2x01_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0002 (compatible alternatives: 172064-0002, 172064-1002), 1 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +2 +2 +Connector_Molex +Molex_Mega-Fit_76825-0004_2x02_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0004 (compatible alternatives: 172064-0004, 172064-1004), 2 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +4 +4 +Connector_Molex +Molex_Mega-Fit_76825-0006_2x03_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0006 (compatible alternatives: 172064-0006, 172064-1006), 3 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +6 +6 +Connector_Molex +Molex_Mega-Fit_76825-0008_2x04_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0008 (compatible alternatives: 172064-0008, 172064-1008), 4 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +8 +8 +Connector_Molex +Molex_Mega-Fit_76825-0010_2x05_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0010 (compatible alternatives: 172064-0010, 172064-1010), 5 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +10 +10 +Connector_Molex +Molex_Mega-Fit_76825-0012_2x06_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0012 (compatible alternatives: 172064-0012, 172064-1012), 6 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +12 +12 +Connector_Molex +Molex_Mega-Fit_76829-0002_2x01_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0002 (compatible alternatives: 172065-0002, 172065-1002), 1 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +2 +2 +Connector_Molex +Molex_Mega-Fit_76829-0004_2x02_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0004 (compatible alternatives: 172065-0004, 172065-1004), 2 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Mega-Fit_76829-0006_2x03_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0006 (compatible alternatives: 172065-0006, 172065-1006), 3 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Mega-Fit_76829-0008_2x04_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0008 (compatible alternatives: 172065-0008, 172065-1008), 4 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Mega-Fit_76829-0010_2x05_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0010 (compatible alternatives: 172065-0010, 172065-1010), 5 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +10 +10 +Connector_Molex +Molex_Mega-Fit_76829-0012_2x06_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0012 (compatible alternatives: 172065-0012, 172065-1012), 6 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +12 +12 +Connector_Molex +Molex_Mega-Fit_76829-0102_2x01_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0102 (compatible alternatives: 172065-0202, 172065-0302), 1 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +2 +2 +Connector_Molex +Molex_Mega-Fit_76829-0104_2x02_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0104 (compatible alternatives: 172065-0204, 172065-0304), 2 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Mega-Fit_76829-0106_2x03_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0106 (compatible alternatives: 172065-0206, 172065-0306), 3 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Mega-Fit_76829-0108_2x04_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0108 (compatible alternatives: 172065-0208, 172065-0308), 4 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Mega-Fit_76829-0110_2x05_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0110 (compatible alternatives: 172065-0210, 172065-0310), 5 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +10 +10 +Connector_Molex +Molex_Mega-Fit_76829-0112_2x06_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0112 (compatible alternatives: 172065-0212, 172065-0312), 6 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0200_2x01_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0200 (alternative finishes: 43045-020x), 1 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0210_2x01-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0210 (compatible alternatives: 43045-0211, 43045-0209), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +4 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0212_2x01_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0212 (compatible alternatives: 43045-0213, 43045-0224), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0215_2x01_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0215 (compatible alternatives: 43045-0216, 43045-0217), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0218_2x01-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0218 (compatible alternatives: 43045-0219, 43045-0220), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +4 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0221_2x01-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0221 (alternative finishes: 43045-022x), 1 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +4 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0400_2x02_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0400 (alternative finishes: 43045-040x), 2 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0410_2x02-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0410 (compatible alternatives: 43045-0411, 43045-0409), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +6 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0412_2x02_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0412 (compatible alternatives: 43045-0413, 43045-0424), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0415_2x02_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0415 (compatible alternatives: 43045-0416, 43045-0417), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0418_2x02-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0418 (compatible alternatives: 43045-0419, 43045-0420), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +6 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0421_2x02-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0421 (alternative finishes: 43045-042x), 2 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +6 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0600_2x03_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0600 (alternative finishes: 43045-060x), 3 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0610_2x03-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0610 (compatible alternatives: 43045-0611, 43045-0609), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +8 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0612_2x03_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0612 (compatible alternatives: 43045-0613, 43045-0624), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0615_2x03_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0615 (compatible alternatives: 43045-0616, 43045-0617), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0618_2x03-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0618 (compatible alternatives: 43045-0619, 43045-0620), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +8 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0621_2x03-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0621 (alternative finishes: 43045-062x), 3 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +8 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0800_2x04_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0800 (alternative finishes: 43045-080x), 4 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0810_2x04-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0810 (compatible alternatives: 43045-0811, 43045-0809), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +10 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0812_2x04_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0812 (compatible alternatives: 43045-0813, 43045-0824), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0815_2x04_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0815 (compatible alternatives: 43045-0816, 43045-0817), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0818_2x04-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0818 (compatible alternatives: 43045-0819, 43045-0820), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +10 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0821_2x04-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0821 (alternative finishes: 43045-082x), 4 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +10 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1000_2x05_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1000 (alternative finishes: 43045-100x), 5 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1010_2x05-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1010 (compatible alternatives: 43045-1011, 43045-1009), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +12 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1012_2x05_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1012 (compatible alternatives: 43045-1013, 43045-1024), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1015_2x05_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1015 (compatible alternatives: 43045-1016, 43045-1017), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1018_2x05-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1018 (compatible alternatives: 43045-1019, 43045-1020), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +12 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1021_2x05-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1021 (alternative finishes: 43045-102x), 5 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +12 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1200_2x06_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1200 (alternative finishes: 43045-120x), 6 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1210_2x06-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1210 (compatible alternatives: 43045-1211, 43045-1209), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +14 +13 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1212_2x06_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1212 (compatible alternatives: 43045-1213, 43045-1224), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1215_2x06_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1215 (compatible alternatives: 43045-1216, 43045-1217), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1218_2x06-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1218 (compatible alternatives: 43045-1219, 43045-1220), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +14 +13 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1221_2x06-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1221 (alternative finishes: 43045-122x), 6 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +14 +13 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1400_2x07_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1400 (alternative finishes: 43045-140x), 7 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +14 +14 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1410_2x07-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1410 (compatible alternatives: 43045-1411, 43045-1409), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +16 +15 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1412_2x07_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1412 (compatible alternatives: 43045-1413, 43045-1424), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +14 +14 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1415_2x07_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1415 (compatible alternatives: 43045-1416, 43045-1417), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +14 +14 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1418_2x07-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1418 (compatible alternatives: 43045-1419, 43045-1420), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +16 +15 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1421_2x07-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1421 (alternative finishes: 43045-142x), 7 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +16 +15 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1600_2x08_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1600 (alternative finishes: 43045-160x), 8 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +16 +16 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1610_2x08-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1610 (compatible alternatives: 43045-1611, 43045-1609), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +18 +17 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1612_2x08_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1612 (compatible alternatives: 43045-1613, 43045-1624), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +16 +16 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1615_2x08_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1615 (compatible alternatives: 43045-1616, 43045-1617), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +16 +16 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1618_2x08-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1618 (compatible alternatives: 43045-1619, 43045-1620), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +18 +17 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1621_2x08-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1621 (alternative finishes: 43045-162x), 8 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +18 +17 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1800_2x09_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1800 (alternative finishes: 43045-180x), 9 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +18 +18 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1810_2x09-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1810 (compatible alternatives: 43045-1811, 43045-1809), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +20 +19 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1812_2x09_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1812 (compatible alternatives: 43045-1813, 43045-1824), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +18 +18 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1815_2x09_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1815 (compatible alternatives: 43045-1816, 43045-1817), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +18 +18 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1818_2x09-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1818 (compatible alternatives: 43045-1819, 43045-1820), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +20 +19 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1821_2x09-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1821 (alternative finishes: 43045-182x), 9 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +20 +19 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2000_2x10_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2000 (alternative finishes: 43045-200x), 10 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +20 +20 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2010_2x10-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2010 (compatible alternatives: 43045-2011, 43045-2009), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +22 +21 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2012_2x10_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2012 (compatible alternatives: 43045-2013, 43045-2024), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +20 +20 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2015_2x10_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2015 (compatible alternatives: 43045-2016, 43045-2017), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +20 +20 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2018_2x10-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2018 (compatible alternatives: 43045-2019, 43045-2020), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +22 +21 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2021_2x10-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2021 (alternative finishes: 43045-202x), 10 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +22 +21 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2200_2x11_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2200 (alternative finishes: 43045-220x), 11 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +22 +22 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2210_2x11-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2210 (compatible alternatives: 43045-2211, 43045-2209), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +24 +23 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2212_2x11_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2212 (compatible alternatives: 43045-2213, 43045-2224), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +22 +22 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2215_2x11_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2215 (compatible alternatives: 43045-2216, 43045-2217), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +22 +22 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2218_2x11-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2218 (compatible alternatives: 43045-2219, 43045-2220), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +24 +23 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2221_2x11-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2221 (alternative finishes: 43045-222x), 11 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +24 +23 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2400_2x12_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2400 (alternative finishes: 43045-240x), 12 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +24 +24 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2410_2x12-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2410 (compatible alternatives: 43045-2411, 43045-2409), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +26 +25 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2412_2x12_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2412 (compatible alternatives: 43045-2413, 43045-2424), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +24 +24 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2415_2x12_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2415 (compatible alternatives: 43045-2416, 43045-2417), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +24 +24 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2418_2x12-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2418 (compatible alternatives: 43045-2419, 43045-2420), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +26 +25 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2421_2x12-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2421 (alternative finishes: 43045-242x), 12 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +26 +25 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0200_1x02_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0200 (compatible alternatives: 43650-0201, 43650-0202), 2 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0215_1x02_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0215 (compatible alternatives: 43650-0216, 43650-0217), 2 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0300_1x03_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0300 (compatible alternatives: 43650-0301, 43650-0302), 3 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +3 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0315_1x03_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0315 (compatible alternatives: 43650-0316, 43650-0317), 3 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +3 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0400_1x04_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0400 (compatible alternatives: 43650-0401, 43650-0402), 4 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0415_1x04_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0415 (compatible alternatives: 43650-0416, 43650-0417), 4 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0500_1x05_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0500 (compatible alternatives: 43650-0501, 43650-0502), 5 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +5 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0515_1x05_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0515 (compatible alternatives: 43650-0516, 43650-0517), 5 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +5 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0600_1x06_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0600 (compatible alternatives: 43650-0601, 43650-0602), 6 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0615_1x06_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0615 (compatible alternatives: 43650-0616, 43650-0617), 6 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0700_1x07_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0700 (compatible alternatives: 43650-0701, 43650-0702), 7 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +7 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0715_1x07_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0715 (compatible alternatives: 43650-0716, 43650-0717), 7 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +7 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0800_1x08_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0800 (compatible alternatives: 43650-0801, 43650-0802), 8 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0815_1x08_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0815 (compatible alternatives: 43650-0816, 43650-0817), 8 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0900_1x09_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0900 (compatible alternatives: 43650-0901, 43650-0902), 9 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +9 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0915_1x09_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0915 (compatible alternatives: 43650-0916, 43650-0917), 9 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +9 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1000_1x10_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-1000 (compatible alternatives: 43650-1001, 43650-1002), 10 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1015_1x10_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-1015 (compatible alternatives: 43650-1016, 43650-1017), 10 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1100_1x11_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-1100 (compatible alternatives: 43650-1101, 43650-1102), 11 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +11 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1115_1x11_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-1115 (compatible alternatives: 43650-1116, 43650-1117), 11 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +11 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1200_1x12_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-1200 (compatible alternatives: 43650-1201, 43650-1202), 12 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1215_1x12_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-1215 (compatible alternatives: 43650-1216, 43650-1217), 12 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +12 +12 +Connector_Molex +Molex_Micro-Latch_53253-0270_1x02_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0270 (compatible alternatives: 53253-0250), 2 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +2 +2 +Connector_Molex +Molex_Micro-Latch_53253-0370_1x03_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0370 (compatible alternatives: 53253-0350), 3 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +3 +3 +Connector_Molex +Molex_Micro-Latch_53253-0470_1x04_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0470 (compatible alternatives: 53253-0450), 4 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +4 +4 +Connector_Molex +Molex_Micro-Latch_53253-0570_1x05_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0570 (compatible alternatives: 53253-0550), 5 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +5 +5 +Connector_Molex +Molex_Micro-Latch_53253-0670_1x06_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0670 (compatible alternatives: 53253-0650), 6 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +6 +6 +Connector_Molex +Molex_Micro-Latch_53253-0770_1x07_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0770 (compatible alternatives: 53253-0750), 7 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +7 +7 +Connector_Molex +Molex_Micro-Latch_53253-0870_1x08_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0870 (compatible alternatives: 53253-0850), 8 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +8 +8 +Connector_Molex +Molex_Micro-Latch_53253-0970_1x09_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0970 (compatible alternatives: 53253-0950), 9 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +9 +9 +Connector_Molex +Molex_Micro-Latch_53253-1070_1x10_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1070 (compatible alternatives: 53253-1050), 10 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +10 +10 +Connector_Molex +Molex_Micro-Latch_53253-1170_1x11_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1170 (compatible alternatives: 53253-1150), 11 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +11 +11 +Connector_Molex +Molex_Micro-Latch_53253-1270_1x12_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1270 (compatible alternatives: 53253-1250), 12 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Latch_53253-1370_1x13_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1370 (compatible alternatives: 53253-1350), 13 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +13 +13 +Connector_Molex +Molex_Micro-Latch_53253-1470_1x14_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1470 (compatible alternatives: 53253-1450), 14 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +14 +14 +Connector_Molex +Molex_Micro-Latch_53253-1570_1x15_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1570 (compatible alternatives: 53253-1550), 15 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +15 +15 +Connector_Molex +Molex_Micro-Latch_53254-0270_1x02_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0270 (compatible alternatives: 53254-0250), 2 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +2 +2 +Connector_Molex +Molex_Micro-Latch_53254-0370_1x03_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0370 (compatible alternatives: 53254-0350), 3 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +3 +3 +Connector_Molex +Molex_Micro-Latch_53254-0470_1x04_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0470 (compatible alternatives: 53254-0450), 4 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +4 +4 +Connector_Molex +Molex_Micro-Latch_53254-0570_1x05_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0570 (compatible alternatives: 53254-0550), 5 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +5 +5 +Connector_Molex +Molex_Micro-Latch_53254-0670_1x06_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0670 (compatible alternatives: 53254-0650), 6 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +6 +6 +Connector_Molex +Molex_Micro-Latch_53254-0770_1x07_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0770 (compatible alternatives: 53254-0750), 7 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +7 +7 +Connector_Molex +Molex_Micro-Latch_53254-0870_1x08_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0870 (compatible alternatives: 53254-0850), 8 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +8 +8 +Connector_Molex +Molex_Micro-Latch_53254-0970_1x09_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0970 (compatible alternatives: 53254-0950), 9 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +9 +9 +Connector_Molex +Molex_Micro-Latch_53254-1070_1x10_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1070 (compatible alternatives: 53254-1050), 10 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +10 +10 +Connector_Molex +Molex_Micro-Latch_53254-1170_1x11_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1170 (compatible alternatives: 53254-1150), 11 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +11 +11 +Connector_Molex +Molex_Micro-Latch_53254-1270_1x12_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1270 (compatible alternatives: 53254-1250), 12 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +12 +12 +Connector_Molex +Molex_Micro-Latch_53254-1370_1x13_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1370 (compatible alternatives: 53254-1350), 13 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +13 +13 +Connector_Molex +Molex_Micro-Latch_53254-1470_1x14_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1470 (compatible alternatives: 53254-1450), 14 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +14 +14 +Connector_Molex +Molex_Micro-Latch_53254-1570_1x15_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1570 (compatible alternatives: 53254-1550), 15 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55932-0210_1x02_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0210, with PCB locator, 2 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55932-0230_1x02_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0230, 2 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55932-0310_1x03_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0310, with PCB locator, 3 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55932-0330_1x03_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0330, 3 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55932-0410_1x04_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0410, with PCB locator, 4 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55932-0430_1x04_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0430, 4 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55932-0510_1x05_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0510, with PCB locator, 5 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55932-0530_1x05_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0530, 5 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55932-0610_1x06_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0610, with PCB locator, 6 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55932-0630_1x06_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0630, 6 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55932-0710_1x07_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0710, with PCB locator, 7 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55932-0730_1x07_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0730, 7 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55932-0810_1x08_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0810, with PCB locator, 8 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55932-0830_1x08_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0830, 8 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55932-0910_1x09_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0910, with PCB locator, 9 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55932-0930_1x09_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0930, 9 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55932-1010_1x10_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1010, with PCB locator, 10 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55932-1030_1x10_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1030, 10 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55932-1110_1x11_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1110, with PCB locator, 11 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55932-1130_1x11_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1130, 11 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55932-1210_1x12_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1210, with PCB locator, 12 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55932-1230_1x12_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1230, 12 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55932-1310_1x13_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1310, with PCB locator, 13 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55932-1330_1x13_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1330, 13 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55932-1410_1x14_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1410, with PCB locator, 14 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55932-1430_1x14_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1430, 14 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55932-1510_1x15_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1510, with PCB locator, 15 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55932-1530_1x15_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1530, 15 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55935-0210_1x02_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0210, with PCB locator, 2 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55935-0230_1x02_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0230, 2 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55935-0310_1x03_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0310, with PCB locator, 3 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55935-0330_1x03_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0330, 3 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55935-0410_1x04_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0410, with PCB locator, 4 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55935-0430_1x04_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0430, 4 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55935-0510_1x05_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0510, with PCB locator, 5 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55935-0530_1x05_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0530, 5 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55935-0610_1x06_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0610, with PCB locator, 6 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55935-0630_1x06_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0630, 6 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55935-0710_1x07_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0710, with PCB locator, 7 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55935-0730_1x07_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0730, 7 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55935-0810_1x08_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0810, with PCB locator, 8 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55935-0830_1x08_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0830, 8 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55935-0910_1x09_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0910, with PCB locator, 9 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55935-0930_1x09_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0930, 9 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55935-1010_1x10_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1010, with PCB locator, 10 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55935-1030_1x10_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1030, 10 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55935-1110_1x11_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1110, with PCB locator, 11 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55935-1130_1x11_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1130, 11 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55935-1210_1x12_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1210, with PCB locator, 12 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55935-1230_1x12_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1230, 12 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55935-1310_1x13_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1310, with PCB locator, 13 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55935-1330_1x13_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1330, 13 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55935-1410_1x14_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1410, with PCB locator, 14 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55935-1430_1x14_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1430, 14 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55935-1510_1x15_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1510, with PCB locator, 15 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55935-1530_1x15_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1530, 15 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +15 +15 +Connector_Molex +Molex_Mini-Fit_Jr_5566-02A2_2x01_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-02A2, example for new mpn: 39-28-902x, 1 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5566-02A_2x01_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-02A, example for new mpn: 39-28-x02x, 1 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5566-04A2_2x02_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-04A2, example for new mpn: 39-28-904x, 2 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5566-04A_2x02_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-04A, example for new mpn: 39-28-x04x, 2 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5566-06A2_2x03_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-06A2, example for new mpn: 39-28-906x, 3 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5566-06A_2x03_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-06A, example for new mpn: 39-28-x06x, 3 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5566-08A2_2x04_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-08A2, example for new mpn: 39-28-908x, 4 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5566-08A_2x04_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-08A, example for new mpn: 39-28-x08x, 4 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5566-10A2_2x05_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-10A2, example for new mpn: 39-28-910x, 5 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5566-10A_2x05_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-10A, example for new mpn: 39-28-x10x, 5 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5566-12A2_2x06_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-12A2, example for new mpn: 39-28-912x, 6 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5566-12A_2x06_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-12A, example for new mpn: 39-28-x12x, 6 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5566-14A2_2x07_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-14A2, example for new mpn: 39-28-914x, 7 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5566-14A_2x07_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-14A, example for new mpn: 39-28-x14x, 7 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5566-16A2_2x08_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-16A2, example for new mpn: 39-28-916x, 8 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5566-16A_2x08_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-16A, example for new mpn: 39-28-x16x, 8 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5566-18A2_2x09_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-18A2, example for new mpn: 39-28-918x, 9 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5566-18A_2x09_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-18A, example for new mpn: 39-28-x18x, 9 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5566-20A2_2x10_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-20A2, example for new mpn: 39-28-920x, 10 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5566-20A_2x10_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-20A, example for new mpn: 39-28-x20x, 10 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5566-22A2_2x11_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-22A2, example for new mpn: 39-28-922x, 11 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5566-22A_2x11_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-22A, example for new mpn: 39-28-x22x, 11 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5566-24A2_2x12_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-24A2, example for new mpn: 39-28-924x, 12 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Jr_5566-24A_2x12_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-24A, example for new mpn: 39-28-x24x, 12 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Jr_5569-02A1_2x01_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-02A1, example for new mpn: 39-29-4029, 1 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5569-02A2_2x01_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-02A2, example for new mpn: 39-30-0020, 1 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5569-04A1_2x02_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-04A1, example for new mpn: 39-29-4049, 2 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5569-04A2_2x02_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-04A2, example for new mpn: 39-30-0040, 2 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5569-06A1_2x03_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-06A1, example for new mpn: 39-29-4069, 3 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5569-06A2_2x03_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-06A2, example for new mpn: 39-30-0060, 3 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5569-08A1_2x04_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-08A1, example for new mpn: 39-29-4089, 4 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5569-08A2_2x04_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-08A2, example for new mpn: 39-30-0080, 4 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5569-10A1_2x05_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-10A1, example for new mpn: 39-29-4109, 5 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5569-10A2_2x05_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-10A2, example for new mpn: 39-30-0100, 5 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5569-12A1_2x06_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-12A1, example for new mpn: 39-29-4129, 6 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5569-12A2_2x06_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-12A2, example for new mpn: 39-30-0120, 6 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5569-14A1_2x07_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-14A1, example for new mpn: 39-29-4149, 7 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5569-14A2_2x07_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-14A2, example for new mpn: 39-30-0140, 7 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5569-16A1_2x08_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-16A1, example for new mpn: 39-29-4169, 8 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5569-16A2_2x08_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-16A2, example for new mpn: 39-30-0160, 8 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5569-18A1_2x09_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-18A1, example for new mpn: 39-29-4189, 9 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5569-18A2_2x09_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-18A2, example for new mpn: 39-30-0180, 9 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5569-20A1_2x10_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-20A1, example for new mpn: 39-29-4209, 10 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5569-20A2_2x10_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-20A2, example for new mpn: 39-30-0200, 10 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5569-22A1_2x11_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-22A1, example for new mpn: 39-29-4229, 11 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5569-22A2_2x11_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-22A2, example for new mpn: 39-30-0220, 11 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5569-24A1_2x12_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-24A1, example for new mpn: 39-29-4249, 12 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Jr_5569-24A2_2x12_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-24A2, example for new mpn: 39-30-0240, 12 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Sr_42819-22XX_1x02_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-22XX, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +6 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42819-22XX_1x02_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-22XX, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +32 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42819-32XX_1x03_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-32XX, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +8 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42819-32XX_1x03_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-32XX, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +47 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42819-42XX_1x04_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-42XX, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +10 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42819-42XX_1x04_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-42XX, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +62 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42819-52XX_1x05_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-52XX, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +12 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42819-52XX_1x05_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-52XX, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +77 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42819-62XX_1x06_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-62XX, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +14 +6 +Connector_Molex +Molex_Mini-Fit_Sr_42819-62XX_1x06_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-62XX, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +92 +6 +Connector_Molex +Molex_Mini-Fit_Sr_42820-22XX_1x02_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-22XX, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +6 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42820-22XX_1x02_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-22XX, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +32 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42820-32XX_1x03_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-32XX, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +8 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42820-32XX_1x03_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-32XX, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +47 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42820-42XX_1x04_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-42XX, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +10 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42820-42XX_1x04_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-42XX, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +62 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42820-52XX_1x05_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-52XX, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +12 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42820-52XX_1x05_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-52XX, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +77 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42820-62XX_1x06_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-62XX, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +14 +6 +Connector_Molex +Molex_Mini-Fit_Sr_42820-62XX_1x06_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-62XX, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +92 +6 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx06_2x03_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx06, 3 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +14 +6 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx06_2x03_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx06, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +92 +6 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx08_2x04_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx08, 4 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +18 +8 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx08_2x04_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx08, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +122 +8 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx10_2x05_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx10, 5 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +22 +10 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx10_2x05_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx10, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +152 +10 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx12_2x06_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx12, 6 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +26 +12 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx12_2x06_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx12, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +182 +12 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx14_2x07_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx14, 7 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +30 +14 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx14_2x07_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx14, With thermal vias in pads, 7 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +212 +14 +Connector_Molex +Molex_Nano-Fit_105309-xx02_1x02_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx02, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +2 +2 +Connector_Molex +Molex_Nano-Fit_105309-xx03_1x03_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx03, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +3 +3 +Connector_Molex +Molex_Nano-Fit_105309-xx04_1x04_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx04, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105309-xx05_1x05_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx05, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +5 +5 +Connector_Molex +Molex_Nano-Fit_105309-xx06_1x06_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx06, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105309-xx07_1x07_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx07, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +7 +7 +Connector_Molex +Molex_Nano-Fit_105309-xx08_1x08_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx08, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105310-xx04_2x02_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx04, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105310-xx06_2x03_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx06, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105310-xx08_2x04_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx08, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105310-xx10_2x05_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx10, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +10 +10 +Connector_Molex +Molex_Nano-Fit_105310-xx12_2x06_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx12, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +12 +12 +Connector_Molex +Molex_Nano-Fit_105310-xx14_2x07_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx14, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +14 +14 +Connector_Molex +Molex_Nano-Fit_105310-xx16_2x08_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx16, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +16 +16 +Connector_Molex +Molex_Nano-Fit_105313-xx02_1x02_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx02, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +2 +2 +Connector_Molex +Molex_Nano-Fit_105313-xx03_1x03_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx03, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +3 +3 +Connector_Molex +Molex_Nano-Fit_105313-xx04_1x04_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx04, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105313-xx05_1x05_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx05, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +5 +5 +Connector_Molex +Molex_Nano-Fit_105313-xx06_1x06_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx06, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105313-xx07_1x07_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx07, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +7 +7 +Connector_Molex +Molex_Nano-Fit_105313-xx08_1x08_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx08, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105314-xx04_2x02_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx04, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105314-xx06_2x03_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx06, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105314-xx08_2x04_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx08, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105314-xx10_2x05_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx10, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +10 +10 +Connector_Molex +Molex_Nano-Fit_105314-xx12_2x06_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx12, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +12 +12 +Connector_Molex +Molex_Nano-Fit_105314-xx14_2x07_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx14, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +14 +14 +Connector_Molex +Molex_Nano-Fit_105314-xx16_2x08_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx16, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +16 +16 +Connector_Molex +Molex_Panelmate_53780-0270_1x02-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0270 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +4 +3 +Connector_Molex +Molex_Panelmate_53780-0370_1x03-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0370 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +5 +4 +Connector_Molex +Molex_Panelmate_53780-0470_1x04-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0470 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +6 +5 +Connector_Molex +Molex_Panelmate_53780-0570_1x05-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0570 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +7 +6 +Connector_Molex +Molex_Panelmate_53780-0670_1x06-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0670 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +8 +7 +Connector_Molex +Molex_Panelmate_53780-0770_1x07-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0770 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +9 +8 +Connector_Molex +Molex_Panelmate_53780-0870_1x08-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0870 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +10 +9 +Connector_Molex +Molex_Panelmate_53780-0970_1x09-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0970 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +11 +10 +Connector_Molex +Molex_Panelmate_53780-1070_1x10-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1070 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +12 +11 +Connector_Molex +Molex_Panelmate_53780-1270_1x12-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1270 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +14 +13 +Connector_Molex +Molex_Panelmate_53780-1470_1x14-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1470 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +16 +15 +Connector_Molex +Molex_Panelmate_53780-1570_1x15-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1570 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +17 +16 +Connector_Molex +Molex_Panelmate_53780-1870_1x18-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1870 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +20 +19 +Connector_Molex +Molex_Panelmate_53780-3070_1x30-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-3070 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +32 +31 +Connector_Molex +Molex_Pico-Clasp_202396-0207_1x02-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0207 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +4 +3 +Connector_Molex +Molex_Pico-Clasp_202396-0307_1x03-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0307 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +5 +4 +Connector_Molex +Molex_Pico-Clasp_202396-0407_1x04-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0407 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +6 +5 +Connector_Molex +Molex_Pico-Clasp_202396-0507_1x05-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0507 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +7 +6 +Connector_Molex +Molex_Pico-Clasp_202396-0607_1x06-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0607 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +8 +7 +Connector_Molex +Molex_Pico-Clasp_202396-0707_1x07-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0707 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +9 +8 +Connector_Molex +Molex_Pico-Clasp_202396-0807_1x08-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0807 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +10 +9 +Connector_Molex +Molex_Pico-Clasp_202396-0907_1x09-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0907 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +11 +10 +Connector_Molex +Molex_Pico-Clasp_202396-1007_1x10-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1007 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +12 +11 +Connector_Molex +Molex_Pico-Clasp_202396-1107_1x11-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1107 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +13 +12 +Connector_Molex +Molex_Pico-Clasp_202396-1207_1x12-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1207 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +14 +13 +Connector_Molex +Molex_Pico-Clasp_202396-1307_1x13-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1307 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +15 +14 +Connector_Molex +Molex_Pico-Clasp_202396-1407_1x14-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1407 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +16 +15 +Connector_Molex +Molex_Pico-Clasp_202396-1507_1x15-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1507 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +17 +16 +Connector_Molex +Molex_Pico-Clasp_501331-0207_1x02-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0207 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +4 +3 +Connector_Molex +Molex_Pico-Clasp_501331-0307_1x03-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0307 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +5 +4 +Connector_Molex +Molex_Pico-Clasp_501331-0407_1x04-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0407 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +6 +5 +Connector_Molex +Molex_Pico-Clasp_501331-0507_1x05-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0507 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +7 +6 +Connector_Molex +Molex_Pico-Clasp_501331-0607_1x06-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0607 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +8 +7 +Connector_Molex +Molex_Pico-Clasp_501331-0707_1x07-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0707 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +9 +8 +Connector_Molex +Molex_Pico-Clasp_501331-0807_1x08-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0807 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +10 +9 +Connector_Molex +Molex_Pico-Clasp_501331-0907_1x09-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0907 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +11 +10 +Connector_Molex +Molex_Pico-Clasp_501331-1007_1x10-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1007 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +12 +11 +Connector_Molex +Molex_Pico-Clasp_501331-1107_1x11-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1107 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +13 +12 +Connector_Molex +Molex_Pico-Clasp_501331-1207_1x12-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1207 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +14 +13 +Connector_Molex +Molex_Pico-Clasp_501331-1307_1x13-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1307 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +15 +14 +Connector_Molex +Molex_Pico-Clasp_501331-1407_1x14-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1407 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +16 +15 +Connector_Molex +Molex_Pico-Clasp_501331-1507_1x15-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1507 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +17 +16 +Connector_Molex +Molex_Pico-EZmate_78171-0002_1x02-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0002 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +4 +3 +Connector_Molex +Molex_Pico-EZmate_78171-0003_1x03-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0003 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +5 +4 +Connector_Molex +Molex_Pico-EZmate_78171-0004_1x04-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0004 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +6 +5 +Connector_Molex +Molex_Pico-EZmate_78171-0005_1x05-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0005 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +7 +6 +Connector_Molex +Molex_Pico-EZmate_Slim_202656-0021_1x02-1MP_P1.20mm_Vertical +Molex Pico-EZmate_Slim series connector, 202656-0021 (http://www.molex.com/pdm_docs/sd/2026560021_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate_Slim side entry +0 +4 +3 +Connector_Molex +Molex_Pico-Lock_504050-0491_1x04-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0491 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +6 +5 +Connector_Molex +Molex_Pico-Lock_504050-0591_1x05-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0591 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +7 +6 +Connector_Molex +Molex_Pico-Lock_504050-0691_1x06-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0691 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +8 +7 +Connector_Molex +Molex_Pico-Lock_504050-0791_1x07-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0791 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +9 +8 +Connector_Molex +Molex_Pico-Lock_504050-0891_1x08-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0891 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +10 +9 +Connector_Molex +Molex_Pico-Lock_504050-1091_1x10-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-1091 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +12 +11 +Connector_Molex +Molex_Pico-Lock_504050-1291_1x12-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-1291 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +14 +13 +Connector_Molex +Molex_Pico-SPOX_87437-1443_1x14-P1.5mm_Vertical +Molex Pico-SPOX Connector System, 87437-1443, 14 Pins per row (https://www.molex.com/pdm_docs/sd/874371443_sd.pdf#page=2) +molex pico spox 14 +0 +28 +14 +Connector_Molex +Molex_PicoBlade_53047-0210_1x02_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0210, 2 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +2 +2 +Connector_Molex +Molex_PicoBlade_53047-0310_1x03_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0310, 3 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +3 +3 +Connector_Molex +Molex_PicoBlade_53047-0410_1x04_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0410, 4 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +4 +4 +Connector_Molex +Molex_PicoBlade_53047-0510_1x05_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0510, 5 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +5 +5 +Connector_Molex +Molex_PicoBlade_53047-0610_1x06_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0610, 6 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +6 +6 +Connector_Molex +Molex_PicoBlade_53047-0710_1x07_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0710, 7 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +7 +7 +Connector_Molex +Molex_PicoBlade_53047-0810_1x08_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0810, 8 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +8 +8 +Connector_Molex +Molex_PicoBlade_53047-0910_1x09_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0910, 9 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +9 +9 +Connector_Molex +Molex_PicoBlade_53047-1010_1x10_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1010, 10 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +10 +10 +Connector_Molex +Molex_PicoBlade_53047-1110_1x11_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1110, 11 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +11 +11 +Connector_Molex +Molex_PicoBlade_53047-1210_1x12_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1210, 12 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +12 +12 +Connector_Molex +Molex_PicoBlade_53047-1310_1x13_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1310, 13 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +13 +13 +Connector_Molex +Molex_PicoBlade_53047-1410_1x14_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1410, 14 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +14 +14 +Connector_Molex +Molex_PicoBlade_53047-1510_1x15_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1510, 15 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +15 +15 +Connector_Molex +Molex_PicoBlade_53048-0210_1x02_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0210, 2 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +2 +2 +Connector_Molex +Molex_PicoBlade_53048-0310_1x03_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0310, 3 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +3 +3 +Connector_Molex +Molex_PicoBlade_53048-0410_1x04_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0410, 4 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +4 +4 +Connector_Molex +Molex_PicoBlade_53048-0510_1x05_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0510, 5 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +5 +5 +Connector_Molex +Molex_PicoBlade_53048-0610_1x06_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0610, 6 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +6 +6 +Connector_Molex +Molex_PicoBlade_53048-0710_1x07_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0710, 7 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +7 +7 +Connector_Molex +Molex_PicoBlade_53048-0810_1x08_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0810, 8 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +8 +8 +Connector_Molex +Molex_PicoBlade_53048-0910_1x09_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0910, 9 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +9 +9 +Connector_Molex +Molex_PicoBlade_53048-1010_1x10_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1010, 10 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +10 +10 +Connector_Molex +Molex_PicoBlade_53048-1110_1x11_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1110, 11 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +11 +11 +Connector_Molex +Molex_PicoBlade_53048-1210_1x12_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1210, 12 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +12 +12 +Connector_Molex +Molex_PicoBlade_53048-1310_1x13_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1310, 13 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +13 +13 +Connector_Molex +Molex_PicoBlade_53048-1410_1x14_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1410, 14 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +14 +14 +Connector_Molex +Molex_PicoBlade_53048-1510_1x15_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1510, 15 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +15 +15 +Connector_Molex +Molex_PicoBlade_53261-0271_1x02-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0271 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +4 +3 +Connector_Molex +Molex_PicoBlade_53261-0371_1x03-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0371 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +5 +4 +Connector_Molex +Molex_PicoBlade_53261-0471_1x04-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0471 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +6 +5 +Connector_Molex +Molex_PicoBlade_53261-0571_1x05-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0571 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +7 +6 +Connector_Molex +Molex_PicoBlade_53261-0671_1x06-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0671 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +8 +7 +Connector_Molex +Molex_PicoBlade_53261-0771_1x07-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0771 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +9 +8 +Connector_Molex +Molex_PicoBlade_53261-0871_1x08-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0871 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +10 +9 +Connector_Molex +Molex_PicoBlade_53261-0971_1x09-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0971 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +11 +10 +Connector_Molex +Molex_PicoBlade_53261-1071_1x10-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1071 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +12 +11 +Connector_Molex +Molex_PicoBlade_53261-1171_1x11-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1171 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +13 +12 +Connector_Molex +Molex_PicoBlade_53261-1271_1x12-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1271 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +14 +13 +Connector_Molex +Molex_PicoBlade_53261-1371_1x13-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1371 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +15 +14 +Connector_Molex +Molex_PicoBlade_53261-1471_1x14-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1471 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +16 +15 +Connector_Molex +Molex_PicoBlade_53261-1571_1x15-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1571 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +17 +16 +Connector_Molex +Molex_PicoBlade_53261-1771_1x17-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1771 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +19 +18 +Connector_Molex +Molex_PicoBlade_53398-0271_1x02-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0271 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +4 +3 +Connector_Molex +Molex_PicoBlade_53398-0371_1x03-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0371 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +5 +4 +Connector_Molex +Molex_PicoBlade_53398-0471_1x04-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0471 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +6 +5 +Connector_Molex +Molex_PicoBlade_53398-0571_1x05-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0571 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +7 +6 +Connector_Molex +Molex_PicoBlade_53398-0671_1x06-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0671 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +8 +7 +Connector_Molex +Molex_PicoBlade_53398-0771_1x07-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0771 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +9 +8 +Connector_Molex +Molex_PicoBlade_53398-0871_1x08-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0871 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +10 +9 +Connector_Molex +Molex_PicoBlade_53398-0971_1x09-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0971 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +11 +10 +Connector_Molex +Molex_PicoBlade_53398-1071_1x10-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1071 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +12 +11 +Connector_Molex +Molex_PicoBlade_53398-1171_1x11-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1171 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +13 +12 +Connector_Molex +Molex_PicoBlade_53398-1271_1x12-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1271 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +14 +13 +Connector_Molex +Molex_PicoBlade_53398-1371_1x13-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1371 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +15 +14 +Connector_Molex +Molex_PicoBlade_53398-1471_1x14-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1471 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +16 +15 +Connector_Molex +Molex_PicoBlade_53398-1571_1x15-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1571 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +17 +16 +Connector_Molex +Molex_Picoflex_90325-0004_2x02_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0004, 4 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +4 +4 +Connector_Molex +Molex_Picoflex_90325-0006_2x03_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0006, 6 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +6 +6 +Connector_Molex +Molex_Picoflex_90325-0008_2x04_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0008, 8 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +8 +8 +Connector_Molex +Molex_Picoflex_90325-0010_2x05_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0010, 10 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +10 +10 +Connector_Molex +Molex_Picoflex_90325-0012_2x06_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0012, 12 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +12 +12 +Connector_Molex +Molex_Picoflex_90325-0014_2x07_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0014, 14 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +14 +14 +Connector_Molex +Molex_Picoflex_90325-0016_2x08_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0016, 16 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +16 +16 +Connector_Molex +Molex_Picoflex_90325-0018_2x09_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0018, 18 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +18 +18 +Connector_Molex +Molex_Picoflex_90325-0020_2x10_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0020, 20 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +20 +20 +Connector_Molex +Molex_Picoflex_90325-0022_2x11_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0022, 22 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +22 +22 +Connector_Molex +Molex_Picoflex_90325-0024_2x12_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0024, 24 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +24 +24 +Connector_Molex +Molex_Picoflex_90325-0026_2x13_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0026, 26 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +26 +26 +Connector_Molex +Molex_Picoflex_90814-0004_2x02_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0004, 4 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +4 +4 +Connector_Molex +Molex_Picoflex_90814-0006_2x03_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0006, 6 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +6 +6 +Connector_Molex +Molex_Picoflex_90814-0008_2x04_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0008, 8 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +8 +8 +Connector_Molex +Molex_Picoflex_90814-0010_2x05_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0010, 10 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +10 +10 +Connector_Molex +Molex_Picoflex_90814-0012_2x06_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0012, 12 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +12 +12 +Connector_Molex +Molex_Picoflex_90814-0014_2x07_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0014, 14 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +14 +14 +Connector_Molex +Molex_Picoflex_90814-0016_2x08_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0016, 16 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +16 +16 +Connector_Molex +Molex_Picoflex_90814-0018_2x09_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0018, 18 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +18 +18 +Connector_Molex +Molex_Picoflex_90814-0020_2x10_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0020, 20 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +20 +20 +Connector_Molex +Molex_Picoflex_90814-0022_2x11_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0022, 22 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +22 +22 +Connector_Molex +Molex_Picoflex_90814-0024_2x12_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0024, 24 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +24 +24 +Connector_Molex +Molex_Picoflex_90814-0026_2x13_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0026, 26 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +26 +26 +Connector_Molex +Molex_SL_171971-0002_1x02_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0002 (compatible alternatives: 171971-0102, 171971-0202), 2 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +2 +2 +Connector_Molex +Molex_SL_171971-0003_1x03_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0003 (compatible alternatives: 171971-0103, 171971-0203), 3 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +3 +3 +Connector_Molex +Molex_SL_171971-0004_1x04_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0004 (compatible alternatives: 171971-0104, 171971-0204), 4 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +4 +4 +Connector_Molex +Molex_SL_171971-0005_1x05_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0005 (compatible alternatives: 171971-0105, 171971-0205), 5 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +5 +5 +Connector_Molex +Molex_SL_171971-0006_1x06_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0006 (compatible alternatives: 171971-0106, 171971-0206), 6 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +6 +6 +Connector_Molex +Molex_SL_171971-0007_1x07_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0007 (compatible alternatives: 171971-0107, 171971-0207), 7 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +7 +7 +Connector_Molex +Molex_SL_171971-0008_1x08_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0008 (compatible alternatives: 171971-0108, 171971-0208), 8 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +8 +8 +Connector_Molex +Molex_SL_171971-0009_1x09_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0009 (compatible alternatives: 171971-0109, 171971-0209), 9 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +9 +9 +Connector_Molex +Molex_SL_171971-0010_1x10_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0010 (compatible alternatives: 171971-0110, 171971-0210), 10 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +10 +10 +Connector_Molex +Molex_SL_171971-0011_1x11_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0011 (compatible alternatives: 171971-0111, 171971-0211), 11 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +11 +11 +Connector_Molex +Molex_SL_171971-0012_1x12_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0012 (compatible alternatives: 171971-0112, 171971-0212), 12 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +12 +12 +Connector_Molex +Molex_SL_171971-0013_1x13_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0013 (compatible alternatives: 171971-0113, 171971-0213), 13 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +13 +13 +Connector_Molex +Molex_SL_171971-0014_1x14_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0014 (compatible alternatives: 171971-0114, 171971-0214), 14 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +14 +14 +Connector_Molex +Molex_SL_171971-0015_1x15_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0015 (compatible alternatives: 171971-0115, 171971-0215), 15 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +15 +15 +Connector_Molex +Molex_SL_171971-0016_1x16_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0016 (compatible alternatives: 171971-0116, 171971-0216), 16 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +16 +16 +Connector_Molex +Molex_SL_171971-0017_1x17_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0017 (compatible alternatives: 171971-0117, 171971-0217), 17 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +17 +17 +Connector_Molex +Molex_SL_171971-0018_1x18_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0018 (compatible alternatives: 171971-0118, 171971-0218), 18 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +18 +18 +Connector_Molex +Molex_SL_171971-0019_1x19_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0019 (compatible alternatives: 171971-0119, 171971-0219), 19 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +19 +19 +Connector_Molex +Molex_SL_171971-0020_1x20_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0020 (compatible alternatives: 171971-0120, 171971-0220), 20 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +20 +20 +Connector_Molex +Molex_SL_171971-0021_1x21_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0021 (compatible alternatives: 171971-0121, 171971-0221), 21 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +21 +21 +Connector_Molex +Molex_SL_171971-0022_1x22_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0022 (compatible alternatives: 171971-0122, 171971-0222), 22 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +22 +22 +Connector_Molex +Molex_SL_171971-0023_1x23_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0023 (compatible alternatives: 171971-0123, 171971-0223), 23 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +23 +23 +Connector_Molex +Molex_SL_171971-0024_1x24_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0024 (compatible alternatives: 171971-0124, 171971-0224), 24 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +24 +24 +Connector_Molex +Molex_SL_171971-0025_1x25_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0025 (compatible alternatives: 171971-0125, 171971-0225), 25 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +25 +25 +Connector_Molex +Molex_SPOX_5267-02A_1x02_P2.50mm_Vertical +Molex SPOX Connector System, 5267-02A, 2 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +2 +2 +Connector_Molex +Molex_SPOX_5267-03A_1x03_P2.50mm_Vertical +Molex SPOX Connector System, 5267-03A, 3 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +3 +3 +Connector_Molex +Molex_SPOX_5267-04A_1x04_P2.50mm_Vertical +Molex SPOX Connector System, 5267-04A, 4 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +4 +4 +Connector_Molex +Molex_SPOX_5267-05A_1x05_P2.50mm_Vertical +Molex SPOX Connector System, 5267-05A, 5 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +5 +5 +Connector_Molex +Molex_SPOX_5267-06A_1x06_P2.50mm_Vertical +Molex SPOX Connector System, 5267-06A, 6 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +6 +6 +Connector_Molex +Molex_SPOX_5267-07A_1x07_P2.50mm_Vertical +Molex SPOX Connector System, 5267-07A, 7 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +7 +7 +Connector_Molex +Molex_SPOX_5267-08A_1x08_P2.50mm_Vertical +Molex SPOX Connector System, 5267-08A, 8 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +8 +8 +Connector_Molex +Molex_SPOX_5267-09A_1x09_P2.50mm_Vertical +Molex SPOX Connector System, 5267-09A, 9 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +9 +9 +Connector_Molex +Molex_SPOX_5267-10A_1x10_P2.50mm_Vertical +Molex SPOX Connector System, 5267-10A, 10 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +10 +10 +Connector_Molex +Molex_SPOX_5267-11A_1x11_P2.50mm_Vertical +Molex SPOX Connector System, 5267-11A, 11 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +11 +11 +Connector_Molex +Molex_SPOX_5267-12A_1x12_P2.50mm_Vertical +Molex SPOX Connector System, 5267-12A, 12 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +12 +12 +Connector_Molex +Molex_SPOX_5267-13A_1x13_P2.50mm_Vertical +Molex SPOX Connector System, 5267-13A, 13 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +13 +13 +Connector_Molex +Molex_SPOX_5267-14A_1x14_P2.50mm_Vertical +Molex SPOX Connector System, 5267-14A, 14 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +14 +14 +Connector_Molex +Molex_SPOX_5267-15A_1x15_P2.50mm_Vertical +Molex SPOX Connector System, 5267-15A, 15 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +15 +15 +Connector_Molex +Molex_SPOX_5268-02A_1x02_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-02A, 2 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +2 +2 +Connector_Molex +Molex_SPOX_5268-03A_1x03_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-03A, 3 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +3 +3 +Connector_Molex +Molex_SPOX_5268-04A_1x04_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-04A, 4 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +4 +4 +Connector_Molex +Molex_SPOX_5268-05A_1x05_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-05A, 5 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +5 +5 +Connector_Molex +Molex_SPOX_5268-06A_1x06_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-06A, 6 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +6 +6 +Connector_Molex +Molex_SPOX_5268-07A_1x07_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-07A, 7 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +7 +7 +Connector_Molex +Molex_SPOX_5268-08A_1x08_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-08A, 8 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +8 +8 +Connector_Molex +Molex_SPOX_5268-09A_1x09_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-09A, 9 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +9 +9 +Connector_Molex +Molex_SPOX_5268-10A_1x10_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-10A, 10 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +10 +10 +Connector_Molex +Molex_SPOX_5268-11A_1x11_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-11A, 11 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +11 +11 +Connector_Molex +Molex_SPOX_5268-12A_1x12_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-12A, 12 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +12 +12 +Connector_Molex +Molex_SPOX_5268-13A_1x13_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-13A, 13 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +13 +13 +Connector_Molex +Molex_SPOX_5268-14A_1x14_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-14A, 14 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +14 +14 +Connector_Molex +Molex_SPOX_5268-15A_1x15_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-15A, 15 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +15 +15 +Connector_Molex +Molex_Sabre_43160-0102_1x02_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +4 +2 +Connector_Molex +Molex_Sabre_43160-0102_1x02_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +30 +2 +Connector_Molex +Molex_Sabre_43160-0103_1x03_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +6 +3 +Connector_Molex +Molex_Sabre_43160-0103_1x03_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +45 +3 +Connector_Molex +Molex_Sabre_43160-0104_1x04_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +8 +4 +Connector_Molex +Molex_Sabre_43160-0104_1x04_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +60 +4 +Connector_Molex +Molex_Sabre_43160-0105_1x05_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +10 +5 +Connector_Molex +Molex_Sabre_43160-0105_1x05_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +75 +5 +Connector_Molex +Molex_Sabre_43160-0106_1x06_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +12 +6 +Connector_Molex +Molex_Sabre_43160-0106_1x06_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +90 +6 +Connector_Molex +Molex_Sabre_43160-1102_1x02_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +6 +2 +Connector_Molex +Molex_Sabre_43160-1102_1x02_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +32 +2 +Connector_Molex +Molex_Sabre_43160-1103_1x03_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +8 +3 +Connector_Molex +Molex_Sabre_43160-1103_1x03_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +47 +3 +Connector_Molex +Molex_Sabre_43160-1104_1x04_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +10 +4 +Connector_Molex +Molex_Sabre_43160-1104_1x04_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +62 +4 +Connector_Molex +Molex_Sabre_43160-1105_1x05_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +12 +5 +Connector_Molex +Molex_Sabre_43160-1105_1x05_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +77 +5 +Connector_Molex +Molex_Sabre_43160-1106_1x06_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +14 +6 +Connector_Molex +Molex_Sabre_43160-1106_1x06_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +92 +6 +Connector_Molex +Molex_Sabre_43160-2102_1x02_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +6 +2 +Connector_Molex +Molex_Sabre_43160-2102_1x02_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +32 +2 +Connector_Molex +Molex_Sabre_43160-2103_1x03_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +8 +3 +Connector_Molex +Molex_Sabre_43160-2103_1x03_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +47 +3 +Connector_Molex +Molex_Sabre_43160-2104_1x04_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +10 +4 +Connector_Molex +Molex_Sabre_43160-2104_1x04_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +62 +4 +Connector_Molex +Molex_Sabre_43160-2105_1x05_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +12 +5 +Connector_Molex +Molex_Sabre_43160-2105_1x05_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +77 +5 +Connector_Molex +Molex_Sabre_43160-2106_1x06_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +14 +6 +Connector_Molex +Molex_Sabre_43160-2106_1x06_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +92 +6 +Connector_Molex +Molex_Sabre_46007-1102_1x02_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +4 +2 +Connector_Molex +Molex_Sabre_46007-1102_1x02_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +30 +2 +Connector_Molex +Molex_Sabre_46007-1103_1x03_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +6 +3 +Connector_Molex +Molex_Sabre_46007-1103_1x03_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +45 +3 +Connector_Molex +Molex_Sabre_46007-1104_1x04_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +8 +4 +Connector_Molex +Molex_Sabre_46007-1104_1x04_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +60 +4 +Connector_Molex +Molex_Sabre_46007-1105_1x05_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +10 +5 +Connector_Molex +Molex_Sabre_46007-1105_1x05_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +75 +5 +Connector_Molex +Molex_Sabre_46007-1106_1x06_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +12 +6 +Connector_Molex +Molex_Sabre_46007-1106_1x06_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +90 +6 +Connector_Molex +Molex_SlimStack_52991-0208_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0208, 20 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +20 +20 +Connector_Molex +Molex_SlimStack_52991-0308_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0308, 30 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +30 +30 +Connector_Molex +Molex_SlimStack_52991-0408_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0408, 40 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +40 +40 +Connector_Molex +Molex_SlimStack_52991-0508_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0508, 50 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +50 +50 +Connector_Molex +Molex_SlimStack_52991-0608_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0608, 60 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +60 +60 +Connector_Molex +Molex_SlimStack_52991-0708_2x35_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0708, 70 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +70 +70 +Connector_Molex +Molex_SlimStack_52991-0808_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0808, 80 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +80 +80 +Connector_Molex +Molex_SlimStack_53748-0208_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0208, 20 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +20 +20 +Connector_Molex +Molex_SlimStack_53748-0308_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0308, 30 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +30 +30 +Connector_Molex +Molex_SlimStack_53748-0408_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0408, 40 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +40 +40 +Connector_Molex +Molex_SlimStack_53748-0608_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0608, 60 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +60 +60 +Connector_Molex +Molex_SlimStack_53748-0708_2x35_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0708, 70 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +70 +70 +Connector_Molex +Molex_SlimStack_53748-0808_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0808, 80 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +80 +80 +Connector_Molex +Molex_SlimStack_54722-0164_2x08_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0164, 16 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +16 +16 +Connector_Molex +Molex_SlimStack_54722-0204_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0204, 20 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_54722-0224_2x11_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0224, 22 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_54722-0244_2x12_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0244, 24 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_54722-0304_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0304, 30 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_54722-0344_2x17_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0344, 34 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_54722-0404_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0404, 40 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_54722-0504_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0504, 50 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_54722-0604_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0604, 60 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_54722-0804_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0804, 80 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_Molex +Molex_SlimStack_55560-0161_2x08_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0161, 16 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +16 +16 +Connector_Molex +Molex_SlimStack_55560-0201_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0201, 20 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_55560-0221_2x11_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0221, 22 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_55560-0241_2x12_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0241, 24 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_55560-0301_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0301, 30 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_55560-0341_2x17_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0341, 34 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_55560-0401_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0401, 40 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_55560-0501_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0501, 50 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_55560-0601_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0601, 60 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_55560-0801_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0801, 80 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_Molex +Molex_SlimStack_501920-3001_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 501920-3001, 30 Pins (http://www.molex.com/pdm_docs/sd/5019204001_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_501920-4001_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 501920-4001, 40 Pins (http://www.molex.com/pdm_docs/sd/5019204001_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_501920-5001_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 501920-5001, 50 Pins (http://www.molex.com/pdm_docs/sd/5019204001_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_502426-0810_2x04_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-0810, 8 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +8 +8 +Connector_Molex +Molex_SlimStack_502426-1410_2x07_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-1410, 14 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +14 +14 +Connector_Molex +Molex_SlimStack_502426-2010_2x10_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2010, 20 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_502426-2210_2x11_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2210, 22 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_502426-2410_2x12_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2410, 24 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_502426-2610_2x13_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2610, 26 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +26 +26 +Connector_Molex +Molex_SlimStack_502426-3010_2x15_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-3010, 30 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_502426-3210_2x16_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-3210, 32 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +32 +32 +Connector_Molex +Molex_SlimStack_502426-3410_2x17_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-3410, 34 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_502426-4010_2x20_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-4010, 40 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_502426-4410_2x22_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-4410, 44 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +44 +44 +Connector_Molex +Molex_SlimStack_502426-5010_2x25_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-5010, 50 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_502426-6010_2x30_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-6010, 60 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_502426-6410_2x32_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-6410, 64 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +64 +64 +Connector_Molex +Molex_SlimStack_502426-8010_2x40_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-8010, 80 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_Molex +Molex_SlimStack_502430-0820_2x04_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-0820, 8 Pins (http://www.molex.com/pdm_docs/sd/5024300820_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +8 +8 +Connector_Molex +Molex_SlimStack_502430-1410_2x07_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-1410, 14 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +14 +14 +Connector_Molex +Molex_SlimStack_502430-2010_2x10_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2010, 20 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_502430-2210_2x11_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2210, 22 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_502430-2410_2x12_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2410, 24 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_502430-2610_2x13_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2610, 26 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +26 +26 +Connector_Molex +Molex_SlimStack_502430-3010_2x15_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-3010, 30 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_502430-3210_2x16_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-3210, 32 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +32 +32 +Connector_Molex +Molex_SlimStack_502430-3410_2x17_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-3410, 34 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_502430-4010_2x20_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-4010, 40 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_502430-4410_2x22_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-4410, 44 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +44 +44 +Connector_Molex +Molex_SlimStack_502430-5010_2x25_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-5010, 50 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_502430-6010_2x30_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-6010, 60 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_502430-6410_2x32_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-6410, 64 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +64 +64 +Connector_Molex +Molex_SlimStack_502430-8010_2x40_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-8010, 80 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_PCBEdge +4UCON_10156_2x40_P1.27mm_Socket_Horizontal +4UCON 10156 Card edge socket with 80 contacts (40 each side), through-hole, http://www.4uconnector.com/online/object/4udrawing/10156.pdf +4UCON 10156 Card edge socket with 80 contacts +0 +80 +80 +Connector_PCBEdge +BUS_AT +AT ISA 16 bits Bus Edge Connector +BUS ISA AT Edge connector +0 +98 +98 +Connector_PCBEdge +BUS_PCI +PCI bus Edge Connector +PCI bus Edge Connector +0 +240 +120 +Connector_PCBEdge +BUS_PCI_Express_Mini +Mini-PCI Express bus connector (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=11) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Dual +Mini-PCI Express bus connector full size with dual clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=28) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Full +Mini-PCI Express bus connector full size with clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=24) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Half +Mini-PCI Express bus connector half size with clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=25) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCIexpress_x1 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +36 +36 +Connector_PCBEdge +BUS_PCIexpress_x4 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +64 +64 +Connector_PCBEdge +BUS_PCIexpress_x8 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +98 +98 +Connector_PCBEdge +BUS_PCIexpress_x16 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +164 +164 +Connector_PCBEdge +Samtec_MECF-05-0_-L-DV_2x05_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-0_-NP-L-DV_2x05_P1.27mm_Edge +Highspeed card edge connector for PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-05-01-L-DV-WT_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +10 +8 +Connector_PCBEdge +Samtec_MECF-05-01-L-DV_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-01-NP-L-DV-WT_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +12 +10 +Connector_PCBEdge +Samtec_MECF-05-01-NP-L-DV_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-05-02-L-DV-WT_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +10 +8 +Connector_PCBEdge +Samtec_MECF-05-02-L-DV_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-02-NP-L-DV-WT_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +12 +10 +Connector_PCBEdge +Samtec_MECF-05-02-NP-L-DV_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-08-0_-L-DV_2x08_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-0_-NP-L-DV_2x08_P1.27mm_Edge +Highspeed card edge connector for PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-08-01-L-DV-WT_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +16 +14 +Connector_PCBEdge +Samtec_MECF-08-01-L-DV_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-01-NP-L-DV-WT_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +18 +16 +Connector_PCBEdge +Samtec_MECF-08-01-NP-L-DV_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-08-02-L-DV-WT_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +16 +14 +Connector_PCBEdge +Samtec_MECF-08-02-L-DV_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-02-NP-L-DV-WT_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +18 +16 +Connector_PCBEdge +Samtec_MECF-08-02-NP-L-DV_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-20-0_-L-DV_2x20_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-0_-NP-L-DV_2x20_P1.27mm_Edge +Highspeed card edge connector for PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-20-01-L-DV-WT_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +40 +38 +Connector_PCBEdge +Samtec_MECF-20-01-L-DV_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-01-NP-L-DV-WT_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +42 +40 +Connector_PCBEdge +Samtec_MECF-20-01-NP-L-DV_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-20-02-L-DV-WT_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +40 +38 +Connector_PCBEdge +Samtec_MECF-20-02-L-DV_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-02-NP-L-DV-WT_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +42 +40 +Connector_PCBEdge +Samtec_MECF-20-02-NP-L-DV_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-30-0_-L-DV_2x30_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-0_-NP-L-DV_2x30_P1.27mm_Edge +Highspeed card edge connector for PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-30-01-L-DV-WT_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +60 +58 +Connector_PCBEdge +Samtec_MECF-30-01-L-DV_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-01-NP-L-DV-WT_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +62 +60 +Connector_PCBEdge +Samtec_MECF-30-01-NP-L-DV_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-30-02-L-DV-WT_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +60 +58 +Connector_PCBEdge +Samtec_MECF-30-02-L-DV_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-02-NP-L-DV-WT_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +62 +60 +Connector_PCBEdge +Samtec_MECF-30-02-NP-L-DV_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-40-0_-L-DV_2x40_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-0_-NP-L-DV_2x40_P1.27mm_Edge +Highspeed card edge connector for PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-40-01-L-DV-WT_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +80 +78 +Connector_PCBEdge +Samtec_MECF-40-01-L-DV_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-01-NP-L-DV-WT_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +82 +80 +Connector_PCBEdge +Samtec_MECF-40-01-NP-L-DV_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-40-02-L-DV-WT_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +80 +78 +Connector_PCBEdge +Samtec_MECF-40-02-L-DV_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-02-NP-L-DV-WT_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +82 +80 +Connector_PCBEdge +Samtec_MECF-40-02-NP-L-DV_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-50-0_-L-DV_2x50_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-0_-NP-L-DV_2x50_P1.27mm_Edge +Highspeed card edge connector for PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-50-01-L-DV-WT_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +100 +98 +Connector_PCBEdge +Samtec_MECF-50-01-L-DV_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-01-NP-L-DV-WT_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +102 +100 +Connector_PCBEdge +Samtec_MECF-50-01-NP-L-DV_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-50-02-L-DV-WT_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +100 +98 +Connector_PCBEdge +Samtec_MECF-50-02-L-DV_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-02-NP-L-DV-WT_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +102 +100 +Connector_PCBEdge +Samtec_MECF-50-02-NP-L-DV_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-60-0_-L-DV_2x60_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-0_-NP-L-DV_2x60_P1.27mm_Edge +Highspeed card edge connector for PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-60-01-L-DV-WT_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +118 +116 +Connector_PCBEdge +Samtec_MECF-60-01-L-DV_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-01-NP-L-DV-WT_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +122 +120 +Connector_PCBEdge +Samtec_MECF-60-01-NP-L-DV_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-60-02-L-DV-WT_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +118 +116 +Connector_PCBEdge +Samtec_MECF-60-02-L-DV_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-02-NP-L-DV-WT_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +122 +120 +Connector_PCBEdge +Samtec_MECF-60-02-NP-L-DV_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-70-0_-L-DV_2x70_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-0_-NP-L-DV_2x70_P1.27mm_Edge +Highspeed card edge connector for PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +Samtec_MECF-70-01-L-DV-WT_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +138 +136 +Connector_PCBEdge +Samtec_MECF-70-01-L-DV_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-01-NP-L-DV-WT_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +142 +140 +Connector_PCBEdge +Samtec_MECF-70-01-NP-L-DV_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +Samtec_MECF-70-02-L-DV-WT_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +138 +136 +Connector_PCBEdge +Samtec_MECF-70-02-L-DV_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-02-NP-L-DV-WT_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +142 +140 +Connector_PCBEdge +Samtec_MECF-70-02-NP-L-DV_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +molex_EDGELOCK_2-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +2 +2 +Connector_PCBEdge +molex_EDGELOCK_4-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +4 +4 +Connector_PCBEdge +molex_EDGELOCK_6-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +6 +6 +Connector_PCBEdge +molex_EDGELOCK_8-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_2-G-7,62_1x02_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/2-G-7,62; number of pins: 02; pin pitch: 7.62mm; Angled || order number: 1766233 12A 630V +phoenix_contact connector GMSTBA_01x02_G_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_2-G_1x02_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/2-G; number of pins: 02; pin pitch: 7.50mm; Angled || order number: 1766343 12A 630V +phoenix_contact connector GMSTBA_01x02_G_7.50mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_3-G-7,62_1x03_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/3-G-7,62; number of pins: 03; pin pitch: 7.62mm; Angled || order number: 1766246 12A 630V +phoenix_contact connector GMSTBA_01x03_G_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_3-G_1x03_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/3-G; number of pins: 03; pin pitch: 7.50mm; Angled || order number: 1766356 12A 630V +phoenix_contact connector GMSTBA_01x03_G_7.50mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_4-G-7,62_1x04_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/4-G-7,62; number of pins: 04; pin pitch: 7.62mm; Angled || order number: 1766259 12A 630V +phoenix_contact connector GMSTBA_01x04_G_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_4-G_1x04_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/4-G; number of pins: 04; pin pitch: 7.50mm; Angled || order number: 1766369 12A 630V +phoenix_contact connector GMSTBA_01x04_G_7.50mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_5-G-7,62_1x05_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/5-G-7,62; number of pins: 05; pin pitch: 7.62mm; Angled || order number: 1766262 12A 630V +phoenix_contact connector GMSTBA_01x05_G_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_5-G_1x05_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/5-G; number of pins: 05; pin pitch: 7.50mm; Angled || order number: 1766372 12A 630V +phoenix_contact connector GMSTBA_01x05_G_7.50mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_6-G-7,62_1x06_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/6-G-7,62; number of pins: 06; pin pitch: 7.62mm; Angled || order number: 1766275 12A 630V +phoenix_contact connector GMSTBA_01x06_G_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_6-G_1x06_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/6-G; number of pins: 06; pin pitch: 7.50mm; Angled || order number: 1766385 12A 630V +phoenix_contact connector GMSTBA_01x06_G_7.50mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_7-G-7,62_1x07_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/7-G-7,62; number of pins: 07; pin pitch: 7.62mm; Angled || order number: 1766288 12A 630V +phoenix_contact connector GMSTBA_01x07_G_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_7-G_1x07_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/7-G; number of pins: 07; pin pitch: 7.50mm; Angled || order number: 1766398 12A 630V +phoenix_contact connector GMSTBA_01x07_G_7.50mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_8-G-7,62_1x08_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/8-G-7,62; number of pins: 08; pin pitch: 7.62mm; Angled || order number: 1766291 12A 630V +phoenix_contact connector GMSTBA_01x08_G_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_8-G_1x08_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/8-G; number of pins: 08; pin pitch: 7.50mm; Angled || order number: 1766408 12A 630V +phoenix_contact connector GMSTBA_01x08_G_7.50mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_9-G-7,62_1x09_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/9-G-7,62; number of pins: 09; pin pitch: 7.62mm; Angled || order number: 1766301 12A 630V +phoenix_contact connector GMSTBA_01x09_G_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_9-G_1x09_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/9-G; number of pins: 09; pin pitch: 7.50mm; Angled || order number: 1766411 12A 630V +phoenix_contact connector GMSTBA_01x09_G_7.50mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_10-G-7,62_1x10_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/10-G-7,62; number of pins: 10; pin pitch: 7.62mm; Angled || order number: 1766314 12A 630V +phoenix_contact connector GMSTBA_01x10_G_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_10-G_1x10_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/10-G; number of pins: 10; pin pitch: 7.50mm; Angled || order number: 1766424 12A 630V +phoenix_contact connector GMSTBA_01x10_G_7.50mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_11-G-7,62_1x11_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/11-G-7,62; number of pins: 11; pin pitch: 7.62mm; Angled || order number: 1766327 12A 630V +phoenix_contact connector GMSTBA_01x11_G_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_11-G_1x11_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/11-G; number of pins: 11; pin pitch: 7.50mm; Angled || order number: 1766437 12A 630V +phoenix_contact connector GMSTBA_01x11_G_7.50mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_12-G-7,62_1x12_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/12-G-7,62; number of pins: 12; pin pitch: 7.62mm; Angled || order number: 1766330 12A 630V +phoenix_contact connector GMSTBA_01x12_G_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_12-G_1x12_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/12-G; number of pins: 12; pin pitch: 7.50mm; Angled || order number: 1766440 12A 630V +phoenix_contact connector GMSTBA_01x12_G_7.50mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_2-G-7,62_1x02_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/2-G-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical || order number: 1766770 12A 630V +phoenix_contact connector GMSTBVA_01x02_G_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_2-G_1x02_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/2-G; number of pins: 02; pin pitch: 7.50mm; Vertical || order number: 1766660 12A 630V +phoenix_contact connector GMSTBVA_01x02_G_7.50mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_3-G-7,62_1x03_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/3-G-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical || order number: 1766783 12A 630V +phoenix_contact connector GMSTBVA_01x03_G_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_3-G_1x03_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/3-G; number of pins: 03; pin pitch: 7.50mm; Vertical || order number: 1766673 12A 630V +phoenix_contact connector GMSTBVA_01x03_G_7.50mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_4-G-7,62_1x04_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/4-G-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical || order number: 1766796 12A 630V +phoenix_contact connector GMSTBVA_01x04_G_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_4-G_1x04_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/4-G; number of pins: 04; pin pitch: 7.50mm; Vertical || order number: 1766686 12A 630V +phoenix_contact connector GMSTBVA_01x04_G_7.50mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_5-G-7,62_1x05_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/5-G-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical || order number: 1766806 12A 630V +phoenix_contact connector GMSTBVA_01x05_G_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_5-G_1x05_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/5-G; number of pins: 05; pin pitch: 7.50mm; Vertical || order number: 1766699 12A 630V +phoenix_contact connector GMSTBVA_01x05_G_7.50mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_6-G-7,62_1x06_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/6-G-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical || order number: 1766819 12A 630V +phoenix_contact connector GMSTBVA_01x06_G_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_6-G_1x06_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/6-G; number of pins: 06; pin pitch: 7.50mm; Vertical || order number: 1766709 12A 630V +phoenix_contact connector GMSTBVA_01x06_G_7.50mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_7-G-7,62_1x07_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/7-G-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical || order number: 1766822 12A 630V +phoenix_contact connector GMSTBVA_01x07_G_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_7-G_1x07_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/7-G; number of pins: 07; pin pitch: 7.50mm; Vertical || order number: 1766712 12A 630V +phoenix_contact connector GMSTBVA_01x07_G_7.50mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_8-G-7,62_1x08_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/8-G-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical || order number: 1766835 12A 630V +phoenix_contact connector GMSTBVA_01x08_G_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_8-G_1x08_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/8-G; number of pins: 08; pin pitch: 7.50mm; Vertical || order number: 1766725 12A 630V +phoenix_contact connector GMSTBVA_01x08_G_7.50mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_9-G-7,62_1x09_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/9-G-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical || order number: 1766848 12A 630V +phoenix_contact connector GMSTBVA_01x09_G_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_9-G_1x09_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/9-G; number of pins: 09; pin pitch: 7.50mm; Vertical || order number: 1766738 12A 630V +phoenix_contact connector GMSTBVA_01x09_G_7.50mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_10-G-7,62_1x10_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/10-G-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical || order number: 1766851 12A 630V +phoenix_contact connector GMSTBVA_01x10_G_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_10-G_1x10_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/10-G; number of pins: 10; pin pitch: 7.50mm; Vertical || order number: 1766741 12A 630V +phoenix_contact connector GMSTBVA_01x10_G_7.50mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_11-G-7,62_1x11_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/11-G-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical || order number: 1766864 12A 630V +phoenix_contact connector GMSTBVA_01x11_G_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_11-G_1x11_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/11-G; number of pins: 11; pin pitch: 7.50mm; Vertical || order number: 1766754 12A 630V +phoenix_contact connector GMSTBVA_01x11_G_7.50mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_12-G-7,62_1x12_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/12-G-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical || order number: 1766877 12A 630V +phoenix_contact connector GMSTBVA_01x12_G_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_12-G_1x12_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/12-G; number of pins: 12; pin pitch: 7.50mm; Vertical || order number: 1766767 12A 630V +phoenix_contact connector GMSTBVA_01x12_G_7.50mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_2-GF-7,62_1x02_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829154 12A 630V +phoenix_contact connector GMSTBV_01x02_GF_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_2-GF-7,62_1x02_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829154 12A 630V +phoenix_contact connector GMSTBV_01x02_GF_7.62mm_MH +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_3-GF-7,62_1x03_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829167 12A 630V +phoenix_contact connector GMSTBV_01x03_GF_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_3-GF-7,62_1x03_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829167 12A 630V +phoenix_contact connector GMSTBV_01x03_GF_7.62mm_MH +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_4-GF-7,62_1x04_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829170 12A 630V +phoenix_contact connector GMSTBV_01x04_GF_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_4-GF-7,62_1x04_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829170 12A 630V +phoenix_contact connector GMSTBV_01x04_GF_7.62mm_MH +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_5-GF-7,62_1x05_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829183 12A 630V +phoenix_contact connector GMSTBV_01x05_GF_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_5-GF-7,62_1x05_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829183 12A 630V +phoenix_contact connector GMSTBV_01x05_GF_7.62mm_MH +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_6-GF-7,62_1x06_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829196 12A 630V +phoenix_contact connector GMSTBV_01x06_GF_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_6-GF-7,62_1x06_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829196 12A 630V +phoenix_contact connector GMSTBV_01x06_GF_7.62mm_MH +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_7-GF-7,62_1x07_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829206 12A 630V +phoenix_contact connector GMSTBV_01x07_GF_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_7-GF-7,62_1x07_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829206 12A 630V +phoenix_contact connector GMSTBV_01x07_GF_7.62mm_MH +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_8-GF-7,62_1x08_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829219 12A 630V +phoenix_contact connector GMSTBV_01x08_GF_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_8-GF-7,62_1x08_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829219 12A 630V +phoenix_contact connector GMSTBV_01x08_GF_7.62mm_MH +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_9-GF-7,62_1x09_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829222 12A 630V +phoenix_contact connector GMSTBV_01x09_GF_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_9-GF-7,62_1x09_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829222 12A 630V +phoenix_contact connector GMSTBV_01x09_GF_7.62mm_MH +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_10-GF-7,62_1x10_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829235 12A 630V +phoenix_contact connector GMSTBV_01x10_GF_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_10-GF-7,62_1x10_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829235 12A 630V +phoenix_contact connector GMSTBV_01x10_GF_7.62mm_MH +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_11-GF-7,62_1x11_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829248 12A 630V +phoenix_contact connector GMSTBV_01x11_GF_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_11-GF-7,62_1x11_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829248 12A 630V +phoenix_contact connector GMSTBV_01x11_GF_7.62mm_MH +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_12-GF-7,62_1x12_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829251 12A 630V +phoenix_contact connector GMSTBV_01x12_GF_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_12-GF-7,62_1x12_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829251 12A 630V +phoenix_contact connector GMSTBV_01x12_GF_7.62mm_MH +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_2-GF-7,62_1x02_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806229 12A 630V +phoenix_contact connector GMSTB_01x02_GF_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_2-GF-7,62_1x02_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806229 12A 630V +phoenix_contact connector GMSTB_01x02_GF_7.62mm_MH +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_3-GF-7,62_1x03_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806232 12A 630V +phoenix_contact connector GMSTB_01x03_GF_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_3-GF-7,62_1x03_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806232 12A 630V +phoenix_contact connector GMSTB_01x03_GF_7.62mm_MH +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_4-GF-7,62_1x04_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806245 12A 630V +phoenix_contact connector GMSTB_01x04_GF_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_4-GF-7,62_1x04_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806245 12A 630V +phoenix_contact connector GMSTB_01x04_GF_7.62mm_MH +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_5-GF-7,62_1x05_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806258 12A 630V +phoenix_contact connector GMSTB_01x05_GF_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_5-GF-7,62_1x05_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806258 12A 630V +phoenix_contact connector GMSTB_01x05_GF_7.62mm_MH +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_6-GF-7,62_1x06_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806261 12A 630V +phoenix_contact connector GMSTB_01x06_GF_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_6-GF-7,62_1x06_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806261 12A 630V +phoenix_contact connector GMSTB_01x06_GF_7.62mm_MH +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_7-GF-7,62_1x07_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806274 12A 630V +phoenix_contact connector GMSTB_01x07_GF_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_7-GF-7,62_1x07_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806274 12A 630V +phoenix_contact connector GMSTB_01x07_GF_7.62mm_MH +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_8-GF-7,62_1x08_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806287 12A 630V +phoenix_contact connector GMSTB_01x08_GF_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_8-GF-7,62_1x08_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806287 12A 630V +phoenix_contact connector GMSTB_01x08_GF_7.62mm_MH +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_9-GF-7,62_1x09_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806290 12A 630V +phoenix_contact connector GMSTB_01x09_GF_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_9-GF-7,62_1x09_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806290 12A 630V +phoenix_contact connector GMSTB_01x09_GF_7.62mm_MH +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_10-GF-7,62_1x10_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806300 12A 630V +phoenix_contact connector GMSTB_01x10_GF_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_10-GF-7,62_1x10_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806300 12A 630V +phoenix_contact connector GMSTB_01x10_GF_7.62mm_MH +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_11-GF-7,62_1x11_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806313 12A 630V +phoenix_contact connector GMSTB_01x11_GF_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_11-GF-7,62_1x11_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806313 12A 630V +phoenix_contact connector GMSTB_01x11_GF_7.62mm_MH +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_12-GF-7,62_1x12_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806326 12A 630V +phoenix_contact connector GMSTB_01x12_GF_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_12-GF-7,62_1x12_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806326 12A 630V +phoenix_contact connector GMSTB_01x12_GF_7.62mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-G-3.5_1x02_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical || order number: 1843606 8A 160V +phoenix_contact connector MCV_01x02_G_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-G-3.81_1x02_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical || order number: 1803426 8A 160V +phoenix_contact connector MCV_01x02_G_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.5_1x02_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843224 8A 160V +phoenix_contact connector MCV_01x02_GF_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.5_1x02_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843224 8A 160V +phoenix_contact connector MCV_01x02_GF_3.5mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.81_1x02_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830596 8A 160V +phoenix_contact connector MCV_01x02_GF_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.81_1x02_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830596 8A 160V +phoenix_contact connector MCV_01x02_GF_3.81mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-G-3.5_1x03_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical || order number: 1843619 8A 160V +phoenix_contact connector MCV_01x03_G_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-G-3.81_1x03_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical || order number: 1803439 8A 160V +phoenix_contact connector MCV_01x03_G_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.5_1x03_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843237 8A 160V +phoenix_contact connector MCV_01x03_GF_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.5_1x03_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843237 8A 160V +phoenix_contact connector MCV_01x03_GF_3.5mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.81_1x03_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830606 8A 160V +phoenix_contact connector MCV_01x03_GF_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.81_1x03_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830606 8A 160V +phoenix_contact connector MCV_01x03_GF_3.81mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-G-3.5_1x04_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical || order number: 1843622 8A 160V +phoenix_contact connector MCV_01x04_G_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-G-3.81_1x04_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical || order number: 1803442 8A 160V +phoenix_contact connector MCV_01x04_G_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.5_1x04_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843240 8A 160V +phoenix_contact connector MCV_01x04_GF_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.5_1x04_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843240 8A 160V +phoenix_contact connector MCV_01x04_GF_3.5mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.81_1x04_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830619 8A 160V +phoenix_contact connector MCV_01x04_GF_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.81_1x04_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830619 8A 160V +phoenix_contact connector MCV_01x04_GF_3.81mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-G-3.5_1x05_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical || order number: 1843635 8A 160V +phoenix_contact connector MCV_01x05_G_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-G-3.81_1x05_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical || order number: 1803455 8A 160V +phoenix_contact connector MCV_01x05_G_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.5_1x05_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843253 8A 160V +phoenix_contact connector MCV_01x05_GF_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.5_1x05_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843253 8A 160V +phoenix_contact connector MCV_01x05_GF_3.5mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.81_1x05_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830622 8A 160V +phoenix_contact connector MCV_01x05_GF_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.81_1x05_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830622 8A 160V +phoenix_contact connector MCV_01x05_GF_3.81mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-G-3.5_1x06_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical || order number: 1843648 8A 160V +phoenix_contact connector MCV_01x06_G_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-G-3.81_1x06_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical || order number: 1803468 8A 160V +phoenix_contact connector MCV_01x06_G_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.5_1x06_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843266 8A 160V +phoenix_contact connector MCV_01x06_GF_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.5_1x06_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843266 8A 160V +phoenix_contact connector MCV_01x06_GF_3.5mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.81_1x06_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830635 8A 160V +phoenix_contact connector MCV_01x06_GF_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.81_1x06_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830635 8A 160V +phoenix_contact connector MCV_01x06_GF_3.81mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-G-3.5_1x07_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical || order number: 1843651 8A 160V +phoenix_contact connector MCV_01x07_G_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-G-3.81_1x07_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical || order number: 1803471 8A 160V +phoenix_contact connector MCV_01x07_G_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.5_1x07_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843279 8A 160V +phoenix_contact connector MCV_01x07_GF_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.5_1x07_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843279 8A 160V +phoenix_contact connector MCV_01x07_GF_3.5mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.81_1x07_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830648 8A 160V +phoenix_contact connector MCV_01x07_GF_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.81_1x07_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830648 8A 160V +phoenix_contact connector MCV_01x07_GF_3.81mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-G-3.5_1x08_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical || order number: 1843664 8A 160V +phoenix_contact connector MCV_01x08_G_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-G-3.81_1x08_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical || order number: 1803484 8A 160V +phoenix_contact connector MCV_01x08_G_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.5_1x08_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843282 8A 160V +phoenix_contact connector MCV_01x08_GF_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.5_1x08_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843282 8A 160V +phoenix_contact connector MCV_01x08_GF_3.5mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.81_1x08_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830651 8A 160V +phoenix_contact connector MCV_01x08_GF_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.81_1x08_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830651 8A 160V +phoenix_contact connector MCV_01x08_GF_3.81mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-G-3.5_1x09_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical || order number: 1843677 8A 160V +phoenix_contact connector MCV_01x09_G_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-G-3.81_1x09_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical || order number: 1803497 8A 160V +phoenix_contact connector MCV_01x09_G_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.5_1x09_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843295 8A 160V +phoenix_contact connector MCV_01x09_GF_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.5_1x09_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843295 8A 160V +phoenix_contact connector MCV_01x09_GF_3.5mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.81_1x09_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830664 8A 160V +phoenix_contact connector MCV_01x09_GF_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.81_1x09_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830664 8A 160V +phoenix_contact connector MCV_01x09_GF_3.81mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-G-3.5_1x10_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical || order number: 1843680 8A 160V +phoenix_contact connector MCV_01x10_G_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-G-3.81_1x10_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical || order number: 1803507 8A 160V +phoenix_contact connector MCV_01x10_G_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.5_1x10_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843305 8A 160V +phoenix_contact connector MCV_01x10_GF_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.5_1x10_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843305 8A 160V +phoenix_contact connector MCV_01x10_GF_3.5mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.81_1x10_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830677 8A 160V +phoenix_contact connector MCV_01x10_GF_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.81_1x10_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830677 8A 160V +phoenix_contact connector MCV_01x10_GF_3.81mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-G-3.5_1x11_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical || order number: 1843693 8A 160V +phoenix_contact connector MCV_01x11_G_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-G-3.81_1x11_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical || order number: 1803510 8A 160V +phoenix_contact connector MCV_01x11_G_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.5_1x11_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843318 8A 160V +phoenix_contact connector MCV_01x11_GF_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.5_1x11_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843318 8A 160V +phoenix_contact connector MCV_01x11_GF_3.5mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.81_1x11_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830680 8A 160V +phoenix_contact connector MCV_01x11_GF_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.81_1x11_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830680 8A 160V +phoenix_contact connector MCV_01x11_GF_3.81mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-G-3.5_1x12_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical || order number: 1843703 8A 160V +phoenix_contact connector MCV_01x12_G_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-G-3.81_1x12_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical || order number: 1803523 8A 160V +phoenix_contact connector MCV_01x12_G_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.5_1x12_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843321 8A 160V +phoenix_contact connector MCV_01x12_GF_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.5_1x12_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843321 8A 160V +phoenix_contact connector MCV_01x12_GF_3.5mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.81_1x12_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830693 8A 160V +phoenix_contact connector MCV_01x12_GF_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.81_1x12_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830693 8A 160V +phoenix_contact connector MCV_01x12_GF_3.81mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-G-3.5_1x13_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/13-G-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical || order number: 1843716 8A 160V +phoenix_contact connector MCV_01x13_G_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-G-3.81_1x13_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/13-G-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical || order number: 1803536 8A 160V +phoenix_contact connector MCV_01x13_G_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.5_1x13_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843334 8A 160V +phoenix_contact connector MCV_01x13_GF_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.5_1x13_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843334 8A 160V +phoenix_contact connector MCV_01x13_GF_3.5mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.81_1x13_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830703 8A 160V +phoenix_contact connector MCV_01x13_GF_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.81_1x13_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830703 8A 160V +phoenix_contact connector MCV_01x13_GF_3.81mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-G-3.5_1x14_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/14-G-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical || order number: 1843729 8A 160V +phoenix_contact connector MCV_01x14_G_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-G-3.81_1x14_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/14-G-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical || order number: 1803549 8A 160V +phoenix_contact connector MCV_01x14_G_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.5_1x14_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843347 8A 160V +phoenix_contact connector MCV_01x14_GF_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.5_1x14_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843347 8A 160V +phoenix_contact connector MCV_01x14_GF_3.5mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.81_1x14_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830716 8A 160V +phoenix_contact connector MCV_01x14_GF_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.81_1x14_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830716 8A 160V +phoenix_contact connector MCV_01x14_GF_3.81mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-G-3.5_1x15_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/15-G-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical || order number: 1843732 8A 160V +phoenix_contact connector MCV_01x15_G_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-G-3.81_1x15_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/15-G-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical || order number: 1803552 8A 160V +phoenix_contact connector MCV_01x15_G_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.5_1x15_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843350 8A 160V +phoenix_contact connector MCV_01x15_GF_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.5_1x15_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843350 8A 160V +phoenix_contact connector MCV_01x15_GF_3.5mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.81_1x15_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830729 8A 160V +phoenix_contact connector MCV_01x15_GF_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.81_1x15_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830729 8A 160V +phoenix_contact connector MCV_01x15_GF_3.81mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-G-3.5_1x16_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/16-G-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical || order number: 1843745 8A 160V +phoenix_contact connector MCV_01x16_G_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-G-3.81_1x16_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/16-G-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical || order number: 1803565 8A 160V +phoenix_contact connector MCV_01x16_G_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.5_1x16_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843363 8A 160V +phoenix_contact connector MCV_01x16_GF_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.5_1x16_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843363 8A 160V +phoenix_contact connector MCV_01x16_GF_3.5mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.81_1x16_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830732 8A 160V +phoenix_contact connector MCV_01x16_GF_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.81_1x16_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830732 8A 160V +phoenix_contact connector MCV_01x16_GF_3.81mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-G-3.5_1x02_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-3.5; number of pins: 02; pin pitch: 3.50mm; Angled || order number: 1844210 8A 160V +phoenix_contact connector MC_01x02_G_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-G-3.81_1x02_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-3.81; number of pins: 02; pin pitch: 3.81mm; Angled || order number: 1803277 8A 160V +phoenix_contact connector MC_01x02_G_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.5_1x02_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843790 8A 160V +phoenix_contact connector MC_01x02_GF_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.5_1x02_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843790 8A 160V +phoenix_contact connector MC_01x02_GF_3.5mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.81_1x02_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827868 8A 160V +phoenix_contact connector MC_01x02_GF_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.81_1x02_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827868 8A 160V +phoenix_contact connector MC_01x02_GF_3.81mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-G-3.5_1x03_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-3.5; number of pins: 03; pin pitch: 3.50mm; Angled || order number: 1844223 8A 160V +phoenix_contact connector MC_01x03_G_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-G-3.81_1x03_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-3.81; number of pins: 03; pin pitch: 3.81mm; Angled || order number: 1803280 8A 160V +phoenix_contact connector MC_01x03_G_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.5_1x03_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843800 8A 160V +phoenix_contact connector MC_01x03_GF_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.5_1x03_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843800 8A 160V +phoenix_contact connector MC_01x03_GF_3.5mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.81_1x03_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827871 8A 160V +phoenix_contact connector MC_01x03_GF_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.81_1x03_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827871 8A 160V +phoenix_contact connector MC_01x03_GF_3.81mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-G-3.5_1x04_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-3.5; number of pins: 04; pin pitch: 3.50mm; Angled || order number: 1844236 8A 160V +phoenix_contact connector MC_01x04_G_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-G-3.81_1x04_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-3.81; number of pins: 04; pin pitch: 3.81mm; Angled || order number: 1803293 8A 160V +phoenix_contact connector MC_01x04_G_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.5_1x04_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843813 8A 160V +phoenix_contact connector MC_01x04_GF_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.5_1x04_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843813 8A 160V +phoenix_contact connector MC_01x04_GF_3.5mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.81_1x04_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827884 8A 160V +phoenix_contact connector MC_01x04_GF_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.81_1x04_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827884 8A 160V +phoenix_contact connector MC_01x04_GF_3.81mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-G-3.5_1x05_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-3.5; number of pins: 05; pin pitch: 3.50mm; Angled || order number: 1844249 8A 160V +phoenix_contact connector MC_01x05_G_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-G-3.81_1x05_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-3.81; number of pins: 05; pin pitch: 3.81mm; Angled || order number: 1803303 8A 160V +phoenix_contact connector MC_01x05_G_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.5_1x05_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843826 8A 160V +phoenix_contact connector MC_01x05_GF_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.5_1x05_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843826 8A 160V +phoenix_contact connector MC_01x05_GF_3.5mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.81_1x05_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827897 8A 160V +phoenix_contact connector MC_01x05_GF_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.81_1x05_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827897 8A 160V +phoenix_contact connector MC_01x05_GF_3.81mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-G-3.5_1x06_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-3.5; number of pins: 06; pin pitch: 3.50mm; Angled || order number: 1844252 8A 160V +phoenix_contact connector MC_01x06_G_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-G-3.81_1x06_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-3.81; number of pins: 06; pin pitch: 3.81mm; Angled || order number: 1803316 8A 160V +phoenix_contact connector MC_01x06_G_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.5_1x06_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843839 8A 160V +phoenix_contact connector MC_01x06_GF_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.5_1x06_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843839 8A 160V +phoenix_contact connector MC_01x06_GF_3.5mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.81_1x06_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827907 8A 160V +phoenix_contact connector MC_01x06_GF_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.81_1x06_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827907 8A 160V +phoenix_contact connector MC_01x06_GF_3.81mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-G-3.5_1x07_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-3.5; number of pins: 07; pin pitch: 3.50mm; Angled || order number: 1844265 8A 160V +phoenix_contact connector MC_01x07_G_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-G-3.81_1x07_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-3.81; number of pins: 07; pin pitch: 3.81mm; Angled || order number: 1803329 8A 160V +phoenix_contact connector MC_01x07_G_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.5_1x07_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843842 8A 160V +phoenix_contact connector MC_01x07_GF_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.5_1x07_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843842 8A 160V +phoenix_contact connector MC_01x07_GF_3.5mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.81_1x07_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827910 8A 160V +phoenix_contact connector MC_01x07_GF_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.81_1x07_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827910 8A 160V +phoenix_contact connector MC_01x07_GF_3.81mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-G-3.5_1x08_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-3.5; number of pins: 08; pin pitch: 3.50mm; Angled || order number: 1844278 8A 160V +phoenix_contact connector MC_01x08_G_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-G-3.81_1x08_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-3.81; number of pins: 08; pin pitch: 3.81mm; Angled || order number: 1803332 8A 160V +phoenix_contact connector MC_01x08_G_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.5_1x08_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843855 8A 160V +phoenix_contact connector MC_01x08_GF_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.5_1x08_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843855 8A 160V +phoenix_contact connector MC_01x08_GF_3.5mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.81_1x08_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827923 8A 160V +phoenix_contact connector MC_01x08_GF_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.81_1x08_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827923 8A 160V +phoenix_contact connector MC_01x08_GF_3.81mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-G-3.5_1x09_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-3.5; number of pins: 09; pin pitch: 3.50mm; Angled || order number: 1844281 8A 160V +phoenix_contact connector MC_01x09_G_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-G-3.81_1x09_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-3.81; number of pins: 09; pin pitch: 3.81mm; Angled || order number: 1803345 8A 160V +phoenix_contact connector MC_01x09_G_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.5_1x09_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843868 8A 160V +phoenix_contact connector MC_01x09_GF_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.5_1x09_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843868 8A 160V +phoenix_contact connector MC_01x09_GF_3.5mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.81_1x09_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827936 8A 160V +phoenix_contact connector MC_01x09_GF_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.81_1x09_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827936 8A 160V +phoenix_contact connector MC_01x09_GF_3.81mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-G-3.5_1x10_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-3.5; number of pins: 10; pin pitch: 3.50mm; Angled || order number: 1844294 8A 160V +phoenix_contact connector MC_01x10_G_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-G-3.81_1x10_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-3.81; number of pins: 10; pin pitch: 3.81mm; Angled || order number: 1803358 8A 160V +phoenix_contact connector MC_01x10_G_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.5_1x10_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843871 8A 160V +phoenix_contact connector MC_01x10_GF_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.5_1x10_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843871 8A 160V +phoenix_contact connector MC_01x10_GF_3.5mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.81_1x10_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827949 8A 160V +phoenix_contact connector MC_01x10_GF_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.81_1x10_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827949 8A 160V +phoenix_contact connector MC_01x10_GF_3.81mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-G-3.5_1x11_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-3.5; number of pins: 11; pin pitch: 3.50mm; Angled || order number: 1844304 8A 160V +phoenix_contact connector MC_01x11_G_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-G-3.81_1x11_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-3.81; number of pins: 11; pin pitch: 3.81mm; Angled || order number: 1803361 8A 160V +phoenix_contact connector MC_01x11_G_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.5_1x11_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843884 8A 160V +phoenix_contact connector MC_01x11_GF_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.5_1x11_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843884 8A 160V +phoenix_contact connector MC_01x11_GF_3.5mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.81_1x11_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827952 8A 160V +phoenix_contact connector MC_01x11_GF_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.81_1x11_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827952 8A 160V +phoenix_contact connector MC_01x11_GF_3.81mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-G-3.5_1x12_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-3.5; number of pins: 12; pin pitch: 3.50mm; Angled || order number: 1844317 8A 160V +phoenix_contact connector MC_01x12_G_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-G-3.81_1x12_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-3.81; number of pins: 12; pin pitch: 3.81mm; Angled || order number: 1803374 8A 160V +phoenix_contact connector MC_01x12_G_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.5_1x12_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843897 8A 160V +phoenix_contact connector MC_01x12_GF_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.5_1x12_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843897 8A 160V +phoenix_contact connector MC_01x12_GF_3.5mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.81_1x12_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827965 8A 160V +phoenix_contact connector MC_01x12_GF_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.81_1x12_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827965 8A 160V +phoenix_contact connector MC_01x12_GF_3.81mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-G-3.5_1x13_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/13-G-3.5; number of pins: 13; pin pitch: 3.50mm; Angled || order number: 1844320 8A 160V +phoenix_contact connector MC_01x13_G_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-G-3.81_1x13_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/13-G-3.81; number of pins: 13; pin pitch: 3.81mm; Angled || order number: 1803387 8A 160V +phoenix_contact connector MC_01x13_G_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.5_1x13_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843907 8A 160V +phoenix_contact connector MC_01x13_GF_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.5_1x13_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843907 8A 160V +phoenix_contact connector MC_01x13_GF_3.5mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.81_1x13_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827978 8A 160V +phoenix_contact connector MC_01x13_GF_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.81_1x13_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827978 8A 160V +phoenix_contact connector MC_01x13_GF_3.81mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-G-3.5_1x14_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/14-G-3.5; number of pins: 14; pin pitch: 3.50mm; Angled || order number: 1844333 8A 160V +phoenix_contact connector MC_01x14_G_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-G-3.81_1x14_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/14-G-3.81; number of pins: 14; pin pitch: 3.81mm; Angled || order number: 1803390 8A 160V +phoenix_contact connector MC_01x14_G_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.5_1x14_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843910 8A 160V +phoenix_contact connector MC_01x14_GF_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.5_1x14_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843910 8A 160V +phoenix_contact connector MC_01x14_GF_3.5mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.81_1x14_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827981 8A 160V +phoenix_contact connector MC_01x14_GF_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.81_1x14_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827981 8A 160V +phoenix_contact connector MC_01x14_GF_3.81mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-G-3.5_1x15_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/15-G-3.5; number of pins: 15; pin pitch: 3.50mm; Angled || order number: 1844346 8A 160V +phoenix_contact connector MC_01x15_G_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-G-3.81_1x15_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/15-G-3.81; number of pins: 15; pin pitch: 3.81mm; Angled || order number: 1803400 8A 160V +phoenix_contact connector MC_01x15_G_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.5_1x15_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843923 8A 160V +phoenix_contact connector MC_01x15_GF_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.5_1x15_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843923 8A 160V +phoenix_contact connector MC_01x15_GF_3.5mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.81_1x15_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827994 8A 160V +phoenix_contact connector MC_01x15_GF_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.81_1x15_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827994 8A 160V +phoenix_contact connector MC_01x15_GF_3.81mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-G-3.5_1x16_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/16-G-3.5; number of pins: 16; pin pitch: 3.50mm; Angled || order number: 1844359 8A 160V +phoenix_contact connector MC_01x16_G_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-G-3.81_1x16_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/16-G-3.81; number of pins: 16; pin pitch: 3.81mm; Angled || order number: 1803413 8A 160V +phoenix_contact connector MC_01x16_G_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.5_1x16_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843936 8A 160V +phoenix_contact connector MC_01x16_GF_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.5_1x16_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843936 8A 160V +phoenix_contact connector MC_01x16_GF_3.5mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.81_1x16_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Angled; threaded flange || order number: 1828003 8A 160V +phoenix_contact connector MC_01x16_GF_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.81_1x16_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1828003 8A 160V +phoenix_contact connector MC_01x16_GF_3.81mm_MH +0 +16 +16 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-G-5.08_1x02_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical || order number: 1836299 8A 320V +phoenix_contact connector MCV_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-GF-5.08_1x02_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847615 8A 320V +phoenix_contact connector MCV_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-GF-5.08_1x02_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847615 8A 320V +phoenix_contact connector MCV_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-G-5.08_1x03_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical || order number: 1836309 8A 320V +phoenix_contact connector MCV_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-GF-5.08_1x03_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847628 8A 320V +phoenix_contact connector MCV_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-GF-5.08_1x03_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847628 8A 320V +phoenix_contact connector MCV_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-G-5.08_1x04_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical || order number: 1836312 8A 320V +phoenix_contact connector MCV_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-GF-5.08_1x04_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847631 8A 320V +phoenix_contact connector MCV_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-GF-5.08_1x04_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847631 8A 320V +phoenix_contact connector MCV_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-G-5.08_1x05_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical || order number: 1836325 8A 320V +phoenix_contact connector MCV_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-GF-5.08_1x05_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847644 8A 320V +phoenix_contact connector MCV_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-GF-5.08_1x05_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847644 8A 320V +phoenix_contact connector MCV_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-G-5.08_1x06_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical || order number: 1836338 8A 320V +phoenix_contact connector MCV_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-GF-5.08_1x06_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847657 8A 320V +phoenix_contact connector MCV_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-GF-5.08_1x06_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847657 8A 320V +phoenix_contact connector MCV_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-G-5.08_1x07_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical || order number: 1836341 8A 320V +phoenix_contact connector MCV_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-GF-5.08_1x07_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847660 8A 320V +phoenix_contact connector MCV_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-GF-5.08_1x07_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847660 8A 320V +phoenix_contact connector MCV_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-G-5.08_1x08_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical || order number: 1836354 8A 320V +phoenix_contact connector MCV_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-GF-5.08_1x08_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847673 8A 320V +phoenix_contact connector MCV_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-GF-5.08_1x08_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847673 8A 320V +phoenix_contact connector MCV_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-G-5.08_1x09_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical || order number: 1836367 8A 320V +phoenix_contact connector MCV_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-GF-5.08_1x09_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847686 8A 320V +phoenix_contact connector MCV_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-GF-5.08_1x09_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847686 8A 320V +phoenix_contact connector MCV_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-G-5.08_1x10_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical || order number: 1836370 8A 320V +phoenix_contact connector MCV_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-GF-5.08_1x10_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847699 8A 320V +phoenix_contact connector MCV_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-GF-5.08_1x10_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847699 8A 320V +phoenix_contact connector MCV_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-G-5.08_1x11_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical || order number: 1836383 8A 320V +phoenix_contact connector MCV_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-GF-5.08_1x11_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847709 8A 320V +phoenix_contact connector MCV_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-GF-5.08_1x11_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847709 8A 320V +phoenix_contact connector MCV_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-G-5.08_1x12_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical || order number: 1836396 8A 320V +phoenix_contact connector MCV_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-GF-5.08_1x12_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847712 8A 320V +phoenix_contact connector MCV_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-GF-5.08_1x12_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847712 8A 320V +phoenix_contact connector MCV_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-G-5.08_1x02_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-5.08; number of pins: 02; pin pitch: 5.08mm; Angled || order number: 1836189 8A 320V +phoenix_contact connector MC_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-GF-5.08_1x02_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847466 8A 320V +phoenix_contact connector MC_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-GF-5.08_1x02_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847466 8A 320V +phoenix_contact connector MC_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-G-5.08_1x03_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-5.08; number of pins: 03; pin pitch: 5.08mm; Angled || order number: 1836192 8A 320V +phoenix_contact connector MC_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-GF-5.08_1x03_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847479 8A 320V +phoenix_contact connector MC_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-GF-5.08_1x03_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847479 8A 320V +phoenix_contact connector MC_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-G-5.08_1x04_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-5.08; number of pins: 04; pin pitch: 5.08mm; Angled || order number: 1836202 8A 320V +phoenix_contact connector MC_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-GF-5.08_1x04_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847482 8A 320V +phoenix_contact connector MC_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-GF-5.08_1x04_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847482 8A 320V +phoenix_contact connector MC_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-G-5.08_1x05_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-5.08; number of pins: 05; pin pitch: 5.08mm; Angled || order number: 1836215 8A 320V +phoenix_contact connector MC_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-GF-5.08_1x05_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847495 8A 320V +phoenix_contact connector MC_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-GF-5.08_1x05_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847495 8A 320V +phoenix_contact connector MC_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-G-5.08_1x06_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-5.08; number of pins: 06; pin pitch: 5.08mm; Angled || order number: 1836228 8A 320V +phoenix_contact connector MC_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-GF-5.08_1x06_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847505 8A 320V +phoenix_contact connector MC_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-GF-5.08_1x06_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847505 8A 320V +phoenix_contact connector MC_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-G-5.08_1x07_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-5.08; number of pins: 07; pin pitch: 5.08mm; Angled || order number: 1836231 8A 320V +phoenix_contact connector MC_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-GF-5.08_1x07_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847518 8A 320V +phoenix_contact connector MC_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-GF-5.08_1x07_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847518 8A 320V +phoenix_contact connector MC_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-G-5.08_1x08_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-5.08; number of pins: 08; pin pitch: 5.08mm; Angled || order number: 1836244 8A 320V +phoenix_contact connector MC_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-GF-5.08_1x08_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847521 8A 320V +phoenix_contact connector MC_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-GF-5.08_1x08_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847521 8A 320V +phoenix_contact connector MC_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-G-5.08_1x09_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-5.08; number of pins: 09; pin pitch: 5.08mm; Angled || order number: 1836257 8A 320V +phoenix_contact connector MC_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-GF-5.08_1x09_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847534 8A 320V +phoenix_contact connector MC_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-GF-5.08_1x09_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847534 8A 320V +phoenix_contact connector MC_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-G-5.08_1x10_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-5.08; number of pins: 10; pin pitch: 5.08mm; Angled || order number: 1836260 8A 320V +phoenix_contact connector MC_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-GF-5.08_1x10_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847547 8A 320V +phoenix_contact connector MC_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-GF-5.08_1x10_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847547 8A 320V +phoenix_contact connector MC_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-G-5.08_1x11_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-5.08; number of pins: 11; pin pitch: 5.08mm; Angled || order number: 1836273 8A 320V +phoenix_contact connector MC_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-GF-5.08_1x11_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847550 8A 320V +phoenix_contact connector MC_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-GF-5.08_1x11_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847550 8A 320V +phoenix_contact connector MC_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-G-5.08_1x12_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-5.08; number of pins: 12; pin pitch: 5.08mm; Angled || order number: 1836286 8A 320V +phoenix_contact connector MC_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-GF-5.08_1x12_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847563 8A 320V +phoenix_contact connector MC_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-GF-5.08_1x12_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847563 8A 320V +phoenix_contact connector MC_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_2-G-5,08_1x02_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/2-G-5,08; number of pins: 02; pin pitch: 5.08mm; Angled || order number: 1757242 12A || order number: 1923869 16A (HC) +phoenix_contact connector MSTBA_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_2-G_1x02_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/2-G; number of pins: 02; pin pitch: 5.00mm; Angled || order number: 1757475 12A || order number: 1923759 16A (HC) +phoenix_contact connector MSTBA_01x02_G_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_3-G-5,08_1x03_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/3-G-5,08; number of pins: 03; pin pitch: 5.08mm; Angled || order number: 1757255 12A || order number: 1923872 16A (HC) +phoenix_contact connector MSTBA_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_3-G_1x03_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/3-G; number of pins: 03; pin pitch: 5.00mm; Angled || order number: 1757488 12A || order number: 1923762 16A (HC) +phoenix_contact connector MSTBA_01x03_G_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_4-G-5,08_1x04_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/4-G-5,08; number of pins: 04; pin pitch: 5.08mm; Angled || order number: 1757268 12A || order number: 1923885 16A (HC) +phoenix_contact connector MSTBA_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_4-G_1x04_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/4-G; number of pins: 04; pin pitch: 5.00mm; Angled || order number: 1757491 12A || order number: 1923775 16A (HC) +phoenix_contact connector MSTBA_01x04_G_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_5-G-5,08_1x05_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/5-G-5,08; number of pins: 05; pin pitch: 5.08mm; Angled || order number: 1757271 12A || order number: 1923898 16A (HC) +phoenix_contact connector MSTBA_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_5-G_1x05_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/5-G; number of pins: 05; pin pitch: 5.00mm; Angled || order number: 1757501 12A || order number: 1923788 16A (HC) +phoenix_contact connector MSTBA_01x05_G_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_6-G-5,08_1x06_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/6-G-5,08; number of pins: 06; pin pitch: 5.08mm; Angled || order number: 1757284 12A || order number: 1923908 16A (HC) +phoenix_contact connector MSTBA_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_6-G_1x06_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/6-G; number of pins: 06; pin pitch: 5.00mm; Angled || order number: 1757514 12A || order number: 1923791 16A (HC) +phoenix_contact connector MSTBA_01x06_G_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_7-G-5,08_1x07_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/7-G-5,08; number of pins: 07; pin pitch: 5.08mm; Angled || order number: 1757297 12A || order number: 1923911 16A (HC) +phoenix_contact connector MSTBA_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_7-G_1x07_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/7-G; number of pins: 07; pin pitch: 5.00mm; Angled || order number: 1757493 12A || order number: 1923801 16A (HC) +phoenix_contact connector MSTBA_01x07_G_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_8-G-5,08_1x08_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/8-G-5,08; number of pins: 08; pin pitch: 5.08mm; Angled || order number: 1757307 12A || order number: 1923924 16A (HC) +phoenix_contact connector MSTBA_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_8-G_1x08_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/8-G; number of pins: 08; pin pitch: 5.00mm; Angled || order number: 1757527 12A || order number: 1923814 16A (HC) +phoenix_contact connector MSTBA_01x08_G_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_9-G-5,08_1x09_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/9-G-5,08; number of pins: 09; pin pitch: 5.08mm; Angled || order number: 1757310 12A || order number: 1923937 16A (HC) +phoenix_contact connector MSTBA_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_9-G_1x09_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/9-G; number of pins: 09; pin pitch: 5.00mm; Angled || order number: 1757530 12A || order number: 1923827 16A (HC) +phoenix_contact connector MSTBA_01x09_G_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_10-G-5,08_1x10_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/10-G-5,08; number of pins: 10; pin pitch: 5.08mm; Angled || order number: 1757323 12A || order number: 1923940 16A (HC) +phoenix_contact connector MSTBA_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_10-G_1x10_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/10-G; number of pins: 10; pin pitch: 5.00mm; Angled || order number: 1757543 12A || order number: 1923830 16A (HC) +phoenix_contact connector MSTBA_01x10_G_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_11-G-5,08_1x11_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/11-G-5,08; number of pins: 11; pin pitch: 5.08mm; Angled || order number: 1757336 12A || order number: 1923953 16A (HC) +phoenix_contact connector MSTBA_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_11-G_1x11_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/11-G; number of pins: 11; pin pitch: 5.00mm; Angled || order number: 1757556 12A || order number: 1923843 16A (HC) +phoenix_contact connector MSTBA_01x11_G_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_12-G-5,08_1x12_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/12-G-5,08; number of pins: 12; pin pitch: 5.08mm; Angled || order number: 1757349 12A || order number: 1923966 16A (HC) +phoenix_contact connector MSTBA_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_12-G_1x12_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/12-G; number of pins: 12; pin pitch: 5.00mm; Angled || order number: 1757569 12A || order number: 1923856 16A (HC) +phoenix_contact connector MSTBA_01x12_G_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_13-G-5,08_1x13_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/13-G-5,08; number of pins: 13; pin pitch: 5.08mm; Angled || order number: 1757352 12A +phoenix_contact connector MSTBA_01x13_G_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_13-G_1x13_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/13-G; number of pins: 13; pin pitch: 5.00mm; Angled || order number: 1757572 12A +phoenix_contact connector MSTBA_01x13_G_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_14-G-5,08_1x14_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/14-G-5,08; number of pins: 14; pin pitch: 5.08mm; Angled || order number: 1757365 12A +phoenix_contact connector MSTBA_01x14_G_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_14-G_1x14_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/14-G; number of pins: 14; pin pitch: 5.00mm; Angled || order number: 1757585 12A +phoenix_contact connector MSTBA_01x14_G_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_15-G-5,08_1x15_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/15-G-5,08; number of pins: 15; pin pitch: 5.08mm; Angled || order number: 1757378 12A +phoenix_contact connector MSTBA_01x15_G_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_15-G_1x15_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/15-G; number of pins: 15; pin pitch: 5.00mm; Angled || order number: 1757598 12A +phoenix_contact connector MSTBA_01x15_G_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_16-G-5,08_1x16_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/16-G-5,08; number of pins: 16; pin pitch: 5.08mm; Angled || order number: 1757381 12A +phoenix_contact connector MSTBA_01x16_G_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_16-G_1x16_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/16-G; number of pins: 16; pin pitch: 5.00mm; Angled || order number: 1757608 12A +phoenix_contact connector MSTBA_01x16_G_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_2-G-5,08_1x02_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/2-G-5,08; number of pins: 02; pin pitch: 5.08mm; Vertical || order number: 1755736 12A || order number: 1924305 16A (HC) +phoenix_contact connector MSTBVA_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_2-G_1x02_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/2-G; number of pins: 02; pin pitch: 5.00mm; Vertical || order number: 1755516 12A || order number: 1924198 16A (HC) +phoenix_contact connector MSTBVA_01x02_G_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_3-G-5,08_1x03_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/3-G-5,08; number of pins: 03; pin pitch: 5.08mm; Vertical || order number: 1755749 12A || order number: 1924318 16A (HC) +phoenix_contact connector MSTBVA_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_3-G_1x03_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/3-G; number of pins: 03; pin pitch: 5.00mm; Vertical || order number: 1755529 12A || order number: 1924208 16A (HC) +phoenix_contact connector MSTBVA_01x03_G_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_4-G-5,08_1x04_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/4-G-5,08; number of pins: 04; pin pitch: 5.08mm; Vertical || order number: 1755752 12A || order number: 1924321 16A (HC) +phoenix_contact connector MSTBVA_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_4-G_1x04_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/4-G; number of pins: 04; pin pitch: 5.00mm; Vertical || order number: 1755532 12A || order number: 1924211 16A (HC) +phoenix_contact connector MSTBVA_01x04_G_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_5-G-5,08_1x05_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/5-G-5,08; number of pins: 05; pin pitch: 5.08mm; Vertical || order number: 1755765 12A || order number: 1924334 16A (HC) +phoenix_contact connector MSTBVA_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_5-G_1x05_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/5-G; number of pins: 05; pin pitch: 5.00mm; Vertical || order number: 1755545 12A || order number: 1924224 16A (HC) +phoenix_contact connector MSTBVA_01x05_G_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_6-G-5,08_1x06_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/6-G-5,08; number of pins: 06; pin pitch: 5.08mm; Vertical || order number: 1755778 12A || order number: 1924347 16A (HC) +phoenix_contact connector MSTBVA_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_6-G_1x06_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/6-G; number of pins: 06; pin pitch: 5.00mm; Vertical || order number: 1755558 12A || order number: 1924237 16A (HC) +phoenix_contact connector MSTBVA_01x06_G_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_7-G-5,08_1x07_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/7-G-5,08; number of pins: 07; pin pitch: 5.08mm; Vertical || order number: 1755781 12A || order number: 1924350 16A (HC) +phoenix_contact connector MSTBVA_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_7-G_1x07_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/7-G; number of pins: 07; pin pitch: 5.00mm; Vertical || order number: 1755561 12A || order number: 1924240 16A (HC) +phoenix_contact connector MSTBVA_01x07_G_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_8-G-5,08_1x08_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/8-G-5,08; number of pins: 08; pin pitch: 5.08mm; Vertical || order number: 1755794 12A || order number: 1924363 16A (HC) +phoenix_contact connector MSTBVA_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_8-G_1x08_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/8-G; number of pins: 08; pin pitch: 5.00mm; Vertical || order number: 1755574 12A || order number: 1924253 16A (HC) +phoenix_contact connector MSTBVA_01x08_G_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_9-G-5,08_1x09_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/9-G-5,08; number of pins: 09; pin pitch: 5.08mm; Vertical || order number: 1755804 12A || order number: 1924376 16A (HC) +phoenix_contact connector MSTBVA_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_9-G_1x09_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/9-G; number of pins: 09; pin pitch: 5.00mm; Vertical || order number: 1755587 12A || order number: 1924266 16A (HC) +phoenix_contact connector MSTBVA_01x09_G_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_10-G-5,08_1x10_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/10-G-5,08; number of pins: 10; pin pitch: 5.08mm; Vertical || order number: 1755817 12A || order number: 1924389 16A (HC) +phoenix_contact connector MSTBVA_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_10-G_1x10_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/10-G; number of pins: 10; pin pitch: 5.00mm; Vertical || order number: 1755503 12A || order number: 1924279 16A (HC) +phoenix_contact connector MSTBVA_01x10_G_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_11-G-5,08_1x11_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/11-G-5,08; number of pins: 11; pin pitch: 5.08mm; Vertical || order number: 1755820 12A || order number: 1924392 16A (HC) +phoenix_contact connector MSTBVA_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_11-G_1x11_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/11-G; number of pins: 11; pin pitch: 5.00mm; Vertical || order number: 1755590 12A || order number: 1924282 16A (HC) +phoenix_contact connector MSTBVA_01x11_G_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_12-G-5,08_1x12_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/12-G-5,08; number of pins: 12; pin pitch: 5.08mm; Vertical || order number: 1755833 12A || order number: 1924402 16A (HC) +phoenix_contact connector MSTBVA_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_12-G_1x12_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/12-G; number of pins: 12; pin pitch: 5.00mm; Vertical || order number: 1755600 12A || order number: 1924295 16A (HC) +phoenix_contact connector MSTBVA_01x12_G_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_13-G-5,08_1x13_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/13-G-5,08; number of pins: 13; pin pitch: 5.08mm; Vertical || order number: 1755846 12A +phoenix_contact connector MSTBVA_01x13_G_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_13-G_1x13_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/13-G; number of pins: 13; pin pitch: 5.00mm; Vertical || order number: 1755613 12A +phoenix_contact connector MSTBVA_01x13_G_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_14-G-5,08_1x14_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/14-G-5,08; number of pins: 14; pin pitch: 5.08mm; Vertical || order number: 1755859 12A +phoenix_contact connector MSTBVA_01x14_G_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_14-G_1x14_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/14-G; number of pins: 14; pin pitch: 5.00mm; Vertical || order number: 1755626 12A +phoenix_contact connector MSTBVA_01x14_G_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_15-G-5,08_1x15_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/15-G-5,08; number of pins: 15; pin pitch: 5.08mm; Vertical || order number: 1755862 12A +phoenix_contact connector MSTBVA_01x15_G_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_15-G_1x15_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/15-G; number of pins: 15; pin pitch: 5.00mm; Vertical || order number: 1755639 12A +phoenix_contact connector MSTBVA_01x15_G_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_16-G-5,08_1x16_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/16-G-5,08; number of pins: 16; pin pitch: 5.08mm; Vertical || order number: 1755875 12A +phoenix_contact connector MSTBVA_01x16_G_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_16-G_1x16_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/16-G; number of pins: 16; pin pitch: 5.00mm; Vertical || order number: 1755642 12A +phoenix_contact connector MSTBVA_01x16_G_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF-5,08_1x02_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777073 12A || order number: 1924525 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF-5,08_1x02_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777073 12A || order number: 1924525 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF_1x02_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776883 12A || order number: 1924415 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF_1x02_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776883 12A || order number: 1924415 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.00mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF-5,08_1x03_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777086 12A || order number: 1924538 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF-5,08_1x03_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777086 12A || order number: 1924538 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF_1x03_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776896 12A || order number: 1924428 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF_1x03_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776896 12A || order number: 1924428 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.00mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF-5,08_1x04_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777099 12A || order number: 1924541 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF-5,08_1x04_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777099 12A || order number: 1924541 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF_1x04_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776906 12A || order number: 1924431 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF_1x04_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776906 12A || order number: 1924431 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.00mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF-5,08_1x05_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777109 12A || order number: 1924554 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF-5,08_1x05_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777109 12A || order number: 1924554 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF_1x05_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776919 12A || order number: 1924444 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF_1x05_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776919 12A || order number: 1924444 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.00mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF-5,08_1x06_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777112 12A || order number: 1924567 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF-5,08_1x06_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777112 12A || order number: 1924567 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF_1x06_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776922 12A || order number: 1924457 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF_1x06_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776922 12A || order number: 1924457 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.00mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF-5,08_1x07_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777125 12A || order number: 1924570 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF-5,08_1x07_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777125 12A || order number: 1924570 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF_1x07_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776935 12A || order number: 1924460 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF_1x07_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776935 12A || order number: 1924460 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.00mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF-5,08_1x08_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777138 12A || order number: 1924583 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF-5,08_1x08_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777138 12A || order number: 1924583 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF_1x08_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776948 12A || order number: 1924473 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF_1x08_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776948 12A || order number: 1924473 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.00mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF-5,08_1x09_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777141 12A || order number: 1924596 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF-5,08_1x09_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777141 12A || order number: 1924596 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF_1x09_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776951 12A || order number: 1924486 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF_1x09_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776951 12A || order number: 1924486 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.00mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF-5,08_1x10_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777154 12A || order number: 1924606 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF-5,08_1x10_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777154 12A || order number: 1924606 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF_1x10_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776964 12A || order number: 1924499 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF_1x10_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776964 12A || order number: 1924499 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.00mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF-5,08_1x11_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777167 12A || order number: 1924619 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF-5,08_1x11_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777167 12A || order number: 1924619 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF_1x11_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776977 12A || order number: 1924509 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF_1x11_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776977 12A || order number: 1924509 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.00mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF-5,08_1x12_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777170 12A || order number: 1924622 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF-5,08_1x12_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777170 12A || order number: 1924622 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF_1x12_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776980 12A || order number: 1924512 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF_1x12_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776980 12A || order number: 1924512 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.00mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF-5,08_1x13_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777183 12A +phoenix_contact connector MSTBV_01x13_GF_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF-5,08_1x13_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777183 12A +phoenix_contact connector MSTBV_01x13_GF_5.08mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF_1x13_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776993 12A +phoenix_contact connector MSTBV_01x13_GF_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF_1x13_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776993 12A +phoenix_contact connector MSTBV_01x13_GF_5.00mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF-5,08_1x14_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777196 12A +phoenix_contact connector MSTBV_01x14_GF_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF-5,08_1x14_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777196 12A +phoenix_contact connector MSTBV_01x14_GF_5.08mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF_1x14_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776002 12A +phoenix_contact connector MSTBV_01x14_GF_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF_1x14_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776002 12A +phoenix_contact connector MSTBV_01x14_GF_5.00mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF-5,08_1x15_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777206 12A +phoenix_contact connector MSTBV_01x15_GF_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF-5,08_1x15_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777206 12A +phoenix_contact connector MSTBV_01x15_GF_5.08mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF_1x15_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776015 12A +phoenix_contact connector MSTBV_01x15_GF_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF_1x15_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776015 12A +phoenix_contact connector MSTBV_01x15_GF_5.00mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF-5,08_1x16_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777219 12A +phoenix_contact connector MSTBV_01x16_GF_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF-5,08_1x16_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777219 12A +phoenix_contact connector MSTBV_01x16_GF_5.08mm_MH +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF_1x16_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776028 12A +phoenix_contact connector MSTBV_01x16_GF_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF_1x16_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776028 12A +phoenix_contact connector MSTBV_01x16_GF_5.00mm_MH +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF-5,08_1x02_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776508 12A || order number: 1924088 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF-5,08_1x02_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776508 12A || order number: 1924088 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF_1x02_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776692 12A || order number: 1923979 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF_1x02_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776692 12A || order number: 1923979 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.00mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF-5,08_1x03_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776511 12A || order number: 1924091 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF-5,08_1x03_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776511 12A || order number: 1924091 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF_1x03_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776702 12A || order number: 1923982 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF_1x03_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776702 12A || order number: 1923982 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.00mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF-5,08_1x04_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776524 12A || order number: 1924101 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF-5,08_1x04_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776524 12A || order number: 1924101 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF_1x04_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776715 12A || order number: 1923995 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF_1x04_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776715 12A || order number: 1923995 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.00mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF-5,08_1x05_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776537 12A || order number: 1924114 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF-5,08_1x05_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776537 12A || order number: 1924114 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF_1x05_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776728 12A || order number: 1924004 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF_1x05_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776728 12A || order number: 1924004 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.00mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF-5,08_1x06_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776540 12A || order number: 1924127 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF-5,08_1x06_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776540 12A || order number: 1924127 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF_1x06_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776731 12A || order number: 1924017 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF_1x06_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776731 12A || order number: 1924017 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.00mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF-5,08_1x07_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776553 12A || order number: 1924130 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF-5,08_1x07_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776553 12A || order number: 1924130 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF_1x07_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776744 12A || order number: 1924020 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF_1x07_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776744 12A || order number: 1924020 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.00mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF-5,08_1x08_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776566 12A || order number: 1924143 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF-5,08_1x08_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776566 12A || order number: 1924143 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF_1x08_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776757 12A || order number: 1924033 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF_1x08_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776757 12A || order number: 1924033 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.00mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF-5,08_1x09_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776579 12A || order number: 1924156 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF-5,08_1x09_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776579 12A || order number: 1924156 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF_1x09_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776760 12A || order number: 1924046 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF_1x09_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776760 12A || order number: 1924046 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.00mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF-5,08_1x10_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776582 12A || order number: 1924169 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF-5,08_1x10_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776582 12A || order number: 1924169 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF_1x10_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776773 12A || order number: 1924059 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF_1x10_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776773 12A || order number: 1924059 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.00mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF-5,08_1x11_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776595 12A || order number: 1924172 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF-5,08_1x11_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776595 12A || order number: 1924172 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF_1x11_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776786 12A || order number: 1924062 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF_1x11_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776786 12A || order number: 1924062 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.00mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF-5,08_1x12_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776605 12A || order number: 1924185 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF-5,08_1x12_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776605 12A || order number: 1924185 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF_1x12_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776799 12A || order number: 1924075 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF_1x12_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776799 12A || order number: 1924075 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.00mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF-5,08_1x13_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776618 12A +phoenix_contact connector MSTB_01x13_GF_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF-5,08_1x13_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776618 12A +phoenix_contact connector MSTB_01x13_GF_5.08mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF_1x13_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776809 12A +phoenix_contact connector MSTB_01x13_GF_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF_1x13_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776809 12A +phoenix_contact connector MSTB_01x13_GF_5.00mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF-5,08_1x14_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776621 12A +phoenix_contact connector MSTB_01x14_GF_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF-5,08_1x14_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776621 12A +phoenix_contact connector MSTB_01x14_GF_5.08mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF_1x14_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776812 12A +phoenix_contact connector MSTB_01x14_GF_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF_1x14_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776812 12A +phoenix_contact connector MSTB_01x14_GF_5.00mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF-5,08_1x15_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776634 12A +phoenix_contact connector MSTB_01x15_GF_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF-5,08_1x15_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776634 12A +phoenix_contact connector MSTB_01x15_GF_5.08mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF_1x15_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776825 12A +phoenix_contact connector MSTB_01x15_GF_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF_1x15_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776825 12A +phoenix_contact connector MSTB_01x15_GF_5.00mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF-5,08_1x16_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776647 12A +phoenix_contact connector MSTB_01x16_GF_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF-5,08_1x16_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776647 12A +phoenix_contact connector MSTB_01x16_GF_5.08mm_MH +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF_1x16_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776838 12A +phoenix_contact connector MSTB_01x16_GF_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF_1x16_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776838 12A +phoenix_contact connector MSTB_01x16_GF_5.00mm_MH +0 +16 +16 +Connector_Pin +Pin_D0.7mm_L6.5mm_W1.8mm_FlatFork +solder Pin_ with flat fork, hole diameter 0.7mm, length 6.5mm, width 1.8mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D0.9mm_L10.0mm_W2.4mm_FlatFork +solder Pin_ with flat fork, hole diameter 0.9mm, length 10.0mm, width 2.4mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.0mm_L10.0mm +solder Pin_ diameter 1.0mm, hole diameter 1.0mm (press fit), length 10.0mm +solder Pin_ press fit +0 +1 +1 +Connector_Pin +Pin_D1.0mm_L10.0mm_LooseFit +solder Pin_ diameter 1.0mm, hole diameter 1.2mm (loose fit), length 10.0mm +solder Pin_ loose fit +0 +1 +1 +Connector_Pin +Pin_D1.1mm_L8.5mm_W2.5mm_FlatFork +solder Pin_ with flat fork, hole diameter 1.1mm, length 8.5mm, width 2.5mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.1mm_L10.2mm_W3.5mm_Flat +solder Pin_ with flat with hole, hole diameter 1.1mm, length 10.2mm, width 3.5mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.2mm_L10.2mm_W2.9mm_FlatFork +solder Pin_ with flat with fork, hole diameter 1.2mm, length 11.3mm, width 3.0mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.2mm_L11.3mm_W3.0mm_Flat +solder Pin_ with flat with hole, hole diameter 1.2mm, length 11.3mm, width 3.0mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L10.0mm_W3.5mm_Flat +solder Pin_ with flat with hole, hole diameter 1.3mm, length 10.0mm, width 3.5mm, e.g. Ettinger 13.13.865, https://katalog.ettinger.de/#p=434 +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.0mm +solder Pin_ diameter 1.3mm, hole diameter 1.3mm, length 11.0mm +solder Pin_ pressfit +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.0mm_LooseFit +solder Pin_ diameter 1.3mm, hole diameter 1.5mm (loose fit), length 11.0mm +solder Pin_ loose fit +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.3mm_W2.8mm_Flat +solder Pin_ with flat with hole, hole diameter 1.3mm, length 11.3mm, width 2.8mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.4mm_L8.5mm_W2.8mm_FlatFork +solder Pin_ with flat with fork, hole diameter 1.4mm, length 8.5mm, width 2.8mm, e.g. Ettinger 13.13.890, https://katalog.ettinger.de/#p=434 +solder Pin_ with flat fork +0 +1 +1 +Connector_PinHeader_1.00mm +PinHeader_1x01_P1.00mm_Horizontal +Through hole angled pin header, 1x01, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x01 1.00mm single row +0 +1 +1 +Connector_PinHeader_1.00mm +PinHeader_1x01_P1.00mm_Vertical +Through hole straight pin header, 1x01, 1.00mm pitch, single row +Through hole pin header THT 1x01 1.00mm single row +0 +1 +1 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Horizontal +Through hole angled pin header, 1x02, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Vertical +Through hole straight pin header, 1x02, 1.00mm pitch, single row +Through hole pin header THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 1.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 1.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Horizontal +Through hole angled pin header, 1x03, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Vertical +Through hole straight pin header, 1x03, 1.00mm pitch, single row +Through hole pin header THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 1.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 1.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Horizontal +Through hole angled pin header, 1x04, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Vertical +Through hole straight pin header, 1x04, 1.00mm pitch, single row +Through hole pin header THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 1.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 1.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Horizontal +Through hole angled pin header, 1x05, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Vertical +Through hole straight pin header, 1x05, 1.00mm pitch, single row +Through hole pin header THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 1.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 1.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Horizontal +Through hole angled pin header, 1x06, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Vertical +Through hole straight pin header, 1x06, 1.00mm pitch, single row +Through hole pin header THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 1.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 1.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Horizontal +Through hole angled pin header, 1x07, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Vertical +Through hole straight pin header, 1x07, 1.00mm pitch, single row +Through hole pin header THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 1.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 1.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Horizontal +Through hole angled pin header, 1x08, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Vertical +Through hole straight pin header, 1x08, 1.00mm pitch, single row +Through hole pin header THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 1.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 1.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Horizontal +Through hole angled pin header, 1x09, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Vertical +Through hole straight pin header, 1x09, 1.00mm pitch, single row +Through hole pin header THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 1.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 1.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Horizontal +Through hole angled pin header, 1x10, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Vertical +Through hole straight pin header, 1x10, 1.00mm pitch, single row +Through hole pin header THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 1.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 1.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Horizontal +Through hole angled pin header, 1x11, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Vertical +Through hole straight pin header, 1x11, 1.00mm pitch, single row +Through hole pin header THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 1.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 1.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Horizontal +Through hole angled pin header, 1x12, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Vertical +Through hole straight pin header, 1x12, 1.00mm pitch, single row +Through hole pin header THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 1.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 1.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Horizontal +Through hole angled pin header, 1x13, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Vertical +Through hole straight pin header, 1x13, 1.00mm pitch, single row +Through hole pin header THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 1.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 1.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Horizontal +Through hole angled pin header, 1x14, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Vertical +Through hole straight pin header, 1x14, 1.00mm pitch, single row +Through hole pin header THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 1.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 1.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Horizontal +Through hole angled pin header, 1x15, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Vertical +Through hole straight pin header, 1x15, 1.00mm pitch, single row +Through hole pin header THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 1.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 1.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Horizontal +Through hole angled pin header, 1x16, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Vertical +Through hole straight pin header, 1x16, 1.00mm pitch, single row +Through hole pin header THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 1.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 1.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Horizontal +Through hole angled pin header, 1x17, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Vertical +Through hole straight pin header, 1x17, 1.00mm pitch, single row +Through hole pin header THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 1.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 1.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Horizontal +Through hole angled pin header, 1x18, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Vertical +Through hole straight pin header, 1x18, 1.00mm pitch, single row +Through hole pin header THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 1.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 1.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Horizontal +Through hole angled pin header, 1x19, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Vertical +Through hole straight pin header, 1x19, 1.00mm pitch, single row +Through hole pin header THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 1.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 1.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Horizontal +Through hole angled pin header, 1x20, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Vertical +Through hole straight pin header, 1x20, 1.00mm pitch, single row +Through hole pin header THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 1.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 1.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Horizontal +Through hole angled pin header, 1x21, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Vertical +Through hole straight pin header, 1x21, 1.00mm pitch, single row +Through hole pin header THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 1.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 1.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Horizontal +Through hole angled pin header, 1x22, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Vertical +Through hole straight pin header, 1x22, 1.00mm pitch, single row +Through hole pin header THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 1.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 1.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Horizontal +Through hole angled pin header, 1x23, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Vertical +Through hole straight pin header, 1x23, 1.00mm pitch, single row +Through hole pin header THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 1.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 1.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Horizontal +Through hole angled pin header, 1x24, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Vertical +Through hole straight pin header, 1x24, 1.00mm pitch, single row +Through hole pin header THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 1.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 1.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Horizontal +Through hole angled pin header, 1x25, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Vertical +Through hole straight pin header, 1x25, 1.00mm pitch, single row +Through hole pin header THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 1.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 1.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Horizontal +Through hole angled pin header, 1x26, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Vertical +Through hole straight pin header, 1x26, 1.00mm pitch, single row +Through hole pin header THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 1.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 1.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Horizontal +Through hole angled pin header, 1x27, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Vertical +Through hole straight pin header, 1x27, 1.00mm pitch, single row +Through hole pin header THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 1.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 1.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Horizontal +Through hole angled pin header, 1x28, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Vertical +Through hole straight pin header, 1x28, 1.00mm pitch, single row +Through hole pin header THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 1.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 1.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Horizontal +Through hole angled pin header, 1x29, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Vertical +Through hole straight pin header, 1x29, 1.00mm pitch, single row +Through hole pin header THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 1.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 1.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Horizontal +Through hole angled pin header, 1x30, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Vertical +Through hole straight pin header, 1x30, 1.00mm pitch, single row +Through hole pin header THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 1.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 1.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Horizontal +Through hole angled pin header, 1x31, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Vertical +Through hole straight pin header, 1x31, 1.00mm pitch, single row +Through hole pin header THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 1.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 1.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Horizontal +Through hole angled pin header, 1x32, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Vertical +Through hole straight pin header, 1x32, 1.00mm pitch, single row +Through hole pin header THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 1.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 1.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Horizontal +Through hole angled pin header, 1x33, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Vertical +Through hole straight pin header, 1x33, 1.00mm pitch, single row +Through hole pin header THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 1.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 1.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Horizontal +Through hole angled pin header, 1x34, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Vertical +Through hole straight pin header, 1x34, 1.00mm pitch, single row +Through hole pin header THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 1.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 1.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Horizontal +Through hole angled pin header, 1x35, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Vertical +Through hole straight pin header, 1x35, 1.00mm pitch, single row +Through hole pin header THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 1.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 1.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Horizontal +Through hole angled pin header, 1x36, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Vertical +Through hole straight pin header, 1x36, 1.00mm pitch, single row +Through hole pin header THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 1.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 1.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Horizontal +Through hole angled pin header, 1x37, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Vertical +Through hole straight pin header, 1x37, 1.00mm pitch, single row +Through hole pin header THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 1.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 1.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Horizontal +Through hole angled pin header, 1x38, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Vertical +Through hole straight pin header, 1x38, 1.00mm pitch, single row +Through hole pin header THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 1.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 1.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Horizontal +Through hole angled pin header, 1x39, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Vertical +Through hole straight pin header, 1x39, 1.00mm pitch, single row +Through hole pin header THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 1.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 1.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Horizontal +Through hole angled pin header, 1x40, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Vertical +Through hole straight pin header, 1x40, 1.00mm pitch, single row +Through hole pin header THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 1.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 1.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x01_P1.00mm_Horizontal +Through hole angled pin header, 2x01, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x01 1.00mm double row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_2x01_P1.00mm_Vertical +Through hole straight pin header, 2x01, 1.00mm pitch, double rows +Through hole pin header THT 2x01 1.00mm double row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_2x01_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x01 1.00mm double row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_2x02_P1.00mm_Horizontal +Through hole angled pin header, 2x02, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x02 1.00mm double row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_2x02_P1.00mm_Vertical +Through hole straight pin header, 2x02, 1.00mm pitch, double rows +Through hole pin header THT 2x02 1.00mm double row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_2x02_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x02 1.00mm double row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_2x03_P1.00mm_Horizontal +Through hole angled pin header, 2x03, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x03 1.00mm double row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_2x03_P1.00mm_Vertical +Through hole straight pin header, 2x03, 1.00mm pitch, double rows +Through hole pin header THT 2x03 1.00mm double row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_2x03_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x03 1.00mm double row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_2x04_P1.00mm_Horizontal +Through hole angled pin header, 2x04, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x04 1.00mm double row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_2x04_P1.00mm_Vertical +Through hole straight pin header, 2x04, 1.00mm pitch, double rows +Through hole pin header THT 2x04 1.00mm double row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_2x04_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x04 1.00mm double row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_2x05_P1.00mm_Horizontal +Through hole angled pin header, 2x05, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x05 1.00mm double row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_2x05_P1.00mm_Vertical +Through hole straight pin header, 2x05, 1.00mm pitch, double rows +Through hole pin header THT 2x05 1.00mm double row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_2x05_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x05 1.00mm double row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_2x06_P1.00mm_Horizontal +Through hole angled pin header, 2x06, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x06 1.00mm double row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_2x06_P1.00mm_Vertical +Through hole straight pin header, 2x06, 1.00mm pitch, double rows +Through hole pin header THT 2x06 1.00mm double row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_2x06_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x06 1.00mm double row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_2x07_P1.00mm_Horizontal +Through hole angled pin header, 2x07, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x07 1.00mm double row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_2x07_P1.00mm_Vertical +Through hole straight pin header, 2x07, 1.00mm pitch, double rows +Through hole pin header THT 2x07 1.00mm double row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_2x07_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x07 1.00mm double row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_2x08_P1.00mm_Horizontal +Through hole angled pin header, 2x08, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x08 1.00mm double row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_2x08_P1.00mm_Vertical +Through hole straight pin header, 2x08, 1.00mm pitch, double rows +Through hole pin header THT 2x08 1.00mm double row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_2x08_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x08 1.00mm double row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_2x09_P1.00mm_Horizontal +Through hole angled pin header, 2x09, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x09 1.00mm double row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_2x09_P1.00mm_Vertical +Through hole straight pin header, 2x09, 1.00mm pitch, double rows +Through hole pin header THT 2x09 1.00mm double row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_2x09_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x09 1.00mm double row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_2x10_P1.00mm_Horizontal +Through hole angled pin header, 2x10, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x10 1.00mm double row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_2x10_P1.00mm_Vertical +Through hole straight pin header, 2x10, 1.00mm pitch, double rows +Through hole pin header THT 2x10 1.00mm double row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_2x10_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x10 1.00mm double row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_2x11_P1.00mm_Horizontal +Through hole angled pin header, 2x11, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x11 1.00mm double row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_2x11_P1.00mm_Vertical +Through hole straight pin header, 2x11, 1.00mm pitch, double rows +Through hole pin header THT 2x11 1.00mm double row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_2x11_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x11 1.00mm double row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_2x12_P1.00mm_Horizontal +Through hole angled pin header, 2x12, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x12 1.00mm double row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_2x12_P1.00mm_Vertical +Through hole straight pin header, 2x12, 1.00mm pitch, double rows +Through hole pin header THT 2x12 1.00mm double row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_2x12_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x12 1.00mm double row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_2x13_P1.00mm_Horizontal +Through hole angled pin header, 2x13, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x13 1.00mm double row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_2x13_P1.00mm_Vertical +Through hole straight pin header, 2x13, 1.00mm pitch, double rows +Through hole pin header THT 2x13 1.00mm double row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_2x13_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x13 1.00mm double row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_2x14_P1.00mm_Horizontal +Through hole angled pin header, 2x14, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x14 1.00mm double row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_2x14_P1.00mm_Vertical +Through hole straight pin header, 2x14, 1.00mm pitch, double rows +Through hole pin header THT 2x14 1.00mm double row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_2x14_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x14 1.00mm double row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_2x15_P1.00mm_Horizontal +Through hole angled pin header, 2x15, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x15 1.00mm double row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_2x15_P1.00mm_Vertical +Through hole straight pin header, 2x15, 1.00mm pitch, double rows +Through hole pin header THT 2x15 1.00mm double row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_2x15_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x15 1.00mm double row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_2x16_P1.00mm_Horizontal +Through hole angled pin header, 2x16, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x16 1.00mm double row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_2x16_P1.00mm_Vertical +Through hole straight pin header, 2x16, 1.00mm pitch, double rows +Through hole pin header THT 2x16 1.00mm double row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_2x16_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x16 1.00mm double row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_2x17_P1.00mm_Horizontal +Through hole angled pin header, 2x17, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x17 1.00mm double row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_2x17_P1.00mm_Vertical +Through hole straight pin header, 2x17, 1.00mm pitch, double rows +Through hole pin header THT 2x17 1.00mm double row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_2x17_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x17 1.00mm double row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_2x18_P1.00mm_Horizontal +Through hole angled pin header, 2x18, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x18 1.00mm double row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_2x18_P1.00mm_Vertical +Through hole straight pin header, 2x18, 1.00mm pitch, double rows +Through hole pin header THT 2x18 1.00mm double row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_2x18_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x18 1.00mm double row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_2x19_P1.00mm_Horizontal +Through hole angled pin header, 2x19, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x19 1.00mm double row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_2x19_P1.00mm_Vertical +Through hole straight pin header, 2x19, 1.00mm pitch, double rows +Through hole pin header THT 2x19 1.00mm double row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_2x19_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x19 1.00mm double row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_2x20_P1.00mm_Horizontal +Through hole angled pin header, 2x20, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x20 1.00mm double row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x20_P1.00mm_Vertical +Through hole straight pin header, 2x20, 1.00mm pitch, double rows +Through hole pin header THT 2x20 1.00mm double row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x20_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x20 1.00mm double row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x21_P1.00mm_Horizontal +Through hole angled pin header, 2x21, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x21 1.00mm double row +0 +42 +42 +Connector_PinHeader_1.00mm +PinHeader_2x21_P1.00mm_Vertical +Through hole straight pin header, 2x21, 1.00mm pitch, double rows +Through hole pin header THT 2x21 1.00mm double row +0 +42 +42 +Connector_PinHeader_1.00mm +PinHeader_2x21_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x21 1.00mm double row +0 +42 +42 +Connector_PinHeader_1.00mm +PinHeader_2x22_P1.00mm_Horizontal +Through hole angled pin header, 2x22, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x22 1.00mm double row +0 +44 +44 +Connector_PinHeader_1.00mm +PinHeader_2x22_P1.00mm_Vertical +Through hole straight pin header, 2x22, 1.00mm pitch, double rows +Through hole pin header THT 2x22 1.00mm double row +0 +44 +44 +Connector_PinHeader_1.00mm +PinHeader_2x22_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x22 1.00mm double row +0 +44 +44 +Connector_PinHeader_1.00mm +PinHeader_2x23_P1.00mm_Horizontal +Through hole angled pin header, 2x23, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x23 1.00mm double row +0 +46 +46 +Connector_PinHeader_1.00mm +PinHeader_2x23_P1.00mm_Vertical +Through hole straight pin header, 2x23, 1.00mm pitch, double rows +Through hole pin header THT 2x23 1.00mm double row +0 +46 +46 +Connector_PinHeader_1.00mm +PinHeader_2x23_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x23 1.00mm double row +0 +46 +46 +Connector_PinHeader_1.00mm +PinHeader_2x24_P1.00mm_Horizontal +Through hole angled pin header, 2x24, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x24 1.00mm double row +0 +48 +48 +Connector_PinHeader_1.00mm +PinHeader_2x24_P1.00mm_Vertical +Through hole straight pin header, 2x24, 1.00mm pitch, double rows +Through hole pin header THT 2x24 1.00mm double row +0 +48 +48 +Connector_PinHeader_1.00mm +PinHeader_2x24_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x24 1.00mm double row +0 +48 +48 +Connector_PinHeader_1.00mm +PinHeader_2x25_P1.00mm_Horizontal +Through hole angled pin header, 2x25, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x25 1.00mm double row +0 +50 +50 +Connector_PinHeader_1.00mm +PinHeader_2x25_P1.00mm_Vertical +Through hole straight pin header, 2x25, 1.00mm pitch, double rows +Through hole pin header THT 2x25 1.00mm double row +0 +50 +50 +Connector_PinHeader_1.00mm +PinHeader_2x25_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x25 1.00mm double row +0 +50 +50 +Connector_PinHeader_1.00mm +PinHeader_2x26_P1.00mm_Horizontal +Through hole angled pin header, 2x26, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x26 1.00mm double row +0 +52 +52 +Connector_PinHeader_1.00mm +PinHeader_2x26_P1.00mm_Vertical +Through hole straight pin header, 2x26, 1.00mm pitch, double rows +Through hole pin header THT 2x26 1.00mm double row +0 +52 +52 +Connector_PinHeader_1.00mm +PinHeader_2x26_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x26 1.00mm double row +0 +52 +52 +Connector_PinHeader_1.00mm +PinHeader_2x27_P1.00mm_Horizontal +Through hole angled pin header, 2x27, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x27 1.00mm double row +0 +54 +54 +Connector_PinHeader_1.00mm +PinHeader_2x27_P1.00mm_Vertical +Through hole straight pin header, 2x27, 1.00mm pitch, double rows +Through hole pin header THT 2x27 1.00mm double row +0 +54 +54 +Connector_PinHeader_1.00mm +PinHeader_2x27_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x27 1.00mm double row +0 +54 +54 +Connector_PinHeader_1.00mm +PinHeader_2x28_P1.00mm_Horizontal +Through hole angled pin header, 2x28, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x28 1.00mm double row +0 +56 +56 +Connector_PinHeader_1.00mm +PinHeader_2x28_P1.00mm_Vertical +Through hole straight pin header, 2x28, 1.00mm pitch, double rows +Through hole pin header THT 2x28 1.00mm double row +0 +56 +56 +Connector_PinHeader_1.00mm +PinHeader_2x28_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x28 1.00mm double row +0 +56 +56 +Connector_PinHeader_1.00mm +PinHeader_2x29_P1.00mm_Horizontal +Through hole angled pin header, 2x29, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x29 1.00mm double row +0 +58 +58 +Connector_PinHeader_1.00mm +PinHeader_2x29_P1.00mm_Vertical +Through hole straight pin header, 2x29, 1.00mm pitch, double rows +Through hole pin header THT 2x29 1.00mm double row +0 +58 +58 +Connector_PinHeader_1.00mm +PinHeader_2x29_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x29 1.00mm double row +0 +58 +58 +Connector_PinHeader_1.00mm +PinHeader_2x30_P1.00mm_Horizontal +Through hole angled pin header, 2x30, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x30 1.00mm double row +0 +60 +60 +Connector_PinHeader_1.00mm +PinHeader_2x30_P1.00mm_Vertical +Through hole straight pin header, 2x30, 1.00mm pitch, double rows +Through hole pin header THT 2x30 1.00mm double row +0 +60 +60 +Connector_PinHeader_1.00mm +PinHeader_2x30_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x30 1.00mm double row +0 +60 +60 +Connector_PinHeader_1.00mm +PinHeader_2x31_P1.00mm_Horizontal +Through hole angled pin header, 2x31, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x31 1.00mm double row +0 +62 +62 +Connector_PinHeader_1.00mm +PinHeader_2x31_P1.00mm_Vertical +Through hole straight pin header, 2x31, 1.00mm pitch, double rows +Through hole pin header THT 2x31 1.00mm double row +0 +62 +62 +Connector_PinHeader_1.00mm +PinHeader_2x31_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x31 1.00mm double row +0 +62 +62 +Connector_PinHeader_1.00mm +PinHeader_2x32_P1.00mm_Horizontal +Through hole angled pin header, 2x32, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x32 1.00mm double row +0 +64 +64 +Connector_PinHeader_1.00mm +PinHeader_2x32_P1.00mm_Vertical +Through hole straight pin header, 2x32, 1.00mm pitch, double rows +Through hole pin header THT 2x32 1.00mm double row +0 +64 +64 +Connector_PinHeader_1.00mm +PinHeader_2x32_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x32 1.00mm double row +0 +64 +64 +Connector_PinHeader_1.00mm +PinHeader_2x33_P1.00mm_Horizontal +Through hole angled pin header, 2x33, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x33 1.00mm double row +0 +66 +66 +Connector_PinHeader_1.00mm +PinHeader_2x33_P1.00mm_Vertical +Through hole straight pin header, 2x33, 1.00mm pitch, double rows +Through hole pin header THT 2x33 1.00mm double row +0 +66 +66 +Connector_PinHeader_1.00mm +PinHeader_2x33_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x33 1.00mm double row +0 +66 +66 +Connector_PinHeader_1.00mm +PinHeader_2x34_P1.00mm_Horizontal +Through hole angled pin header, 2x34, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x34 1.00mm double row +0 +68 +68 +Connector_PinHeader_1.00mm +PinHeader_2x34_P1.00mm_Vertical +Through hole straight pin header, 2x34, 1.00mm pitch, double rows +Through hole pin header THT 2x34 1.00mm double row +0 +68 +68 +Connector_PinHeader_1.00mm +PinHeader_2x34_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x34 1.00mm double row +0 +68 +68 +Connector_PinHeader_1.00mm +PinHeader_2x35_P1.00mm_Horizontal +Through hole angled pin header, 2x35, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x35 1.00mm double row +0 +70 +70 +Connector_PinHeader_1.00mm +PinHeader_2x35_P1.00mm_Vertical +Through hole straight pin header, 2x35, 1.00mm pitch, double rows +Through hole pin header THT 2x35 1.00mm double row +0 +70 +70 +Connector_PinHeader_1.00mm +PinHeader_2x35_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x35 1.00mm double row +0 +70 +70 +Connector_PinHeader_1.00mm +PinHeader_2x36_P1.00mm_Horizontal +Through hole angled pin header, 2x36, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x36 1.00mm double row +0 +72 +72 +Connector_PinHeader_1.00mm +PinHeader_2x36_P1.00mm_Vertical +Through hole straight pin header, 2x36, 1.00mm pitch, double rows +Through hole pin header THT 2x36 1.00mm double row +0 +72 +72 +Connector_PinHeader_1.00mm +PinHeader_2x36_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x36 1.00mm double row +0 +72 +72 +Connector_PinHeader_1.00mm +PinHeader_2x37_P1.00mm_Horizontal +Through hole angled pin header, 2x37, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x37 1.00mm double row +0 +74 +74 +Connector_PinHeader_1.00mm +PinHeader_2x37_P1.00mm_Vertical +Through hole straight pin header, 2x37, 1.00mm pitch, double rows +Through hole pin header THT 2x37 1.00mm double row +0 +74 +74 +Connector_PinHeader_1.00mm +PinHeader_2x37_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x37 1.00mm double row +0 +74 +74 +Connector_PinHeader_1.00mm +PinHeader_2x38_P1.00mm_Horizontal +Through hole angled pin header, 2x38, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x38 1.00mm double row +0 +76 +76 +Connector_PinHeader_1.00mm +PinHeader_2x38_P1.00mm_Vertical +Through hole straight pin header, 2x38, 1.00mm pitch, double rows +Through hole pin header THT 2x38 1.00mm double row +0 +76 +76 +Connector_PinHeader_1.00mm +PinHeader_2x38_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x38 1.00mm double row +0 +76 +76 +Connector_PinHeader_1.00mm +PinHeader_2x39_P1.00mm_Horizontal +Through hole angled pin header, 2x39, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x39 1.00mm double row +0 +78 +78 +Connector_PinHeader_1.00mm +PinHeader_2x39_P1.00mm_Vertical +Through hole straight pin header, 2x39, 1.00mm pitch, double rows +Through hole pin header THT 2x39 1.00mm double row +0 +78 +78 +Connector_PinHeader_1.00mm +PinHeader_2x39_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x39 1.00mm double row +0 +78 +78 +Connector_PinHeader_1.00mm +PinHeader_2x40_P1.00mm_Horizontal +Through hole angled pin header, 2x40, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x40 1.00mm double row +0 +80 +80 +Connector_PinHeader_1.00mm +PinHeader_2x40_P1.00mm_Vertical +Through hole straight pin header, 2x40, 1.00mm pitch, double rows +Through hole pin header THT 2x40 1.00mm double row +0 +80 +80 +Connector_PinHeader_1.00mm +PinHeader_2x40_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x40 1.00mm double row +0 +80 +80 +Connector_PinHeader_1.27mm +PinHeader_1x01_P1.27mm_Horizontal +Through hole angled pin header, 1x01, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x01 1.27mm single row +0 +1 +1 +Connector_PinHeader_1.27mm +PinHeader_1x01_P1.27mm_Vertical +Through hole straight pin header, 1x01, 1.27mm pitch, single row +Through hole pin header THT 1x01 1.27mm single row +0 +1 +1 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Horizontal +Through hole angled pin header, 1x02, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x02 1.27mm single row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Vertical +Through hole straight pin header, 1x02, 1.27mm pitch, single row +Through hole pin header THT 1x02 1.27mm single row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 1.27mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 1.27mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Horizontal +Through hole angled pin header, 1x03, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x03 1.27mm single row +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Vertical +Through hole straight pin header, 1x03, 1.27mm pitch, single row +Through hole pin header THT 1x03 1.27mm single row +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 1.27mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 1.27mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Horizontal +Through hole angled pin header, 1x04, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x04 1.27mm single row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Vertical +Through hole straight pin header, 1x04, 1.27mm pitch, single row +Through hole pin header THT 1x04 1.27mm single row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 1.27mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 1.27mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Horizontal +Through hole angled pin header, 1x05, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x05 1.27mm single row +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Vertical +Through hole straight pin header, 1x05, 1.27mm pitch, single row +Through hole pin header THT 1x05 1.27mm single row +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 1.27mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 1.27mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Horizontal +Through hole angled pin header, 1x06, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x06 1.27mm single row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Vertical +Through hole straight pin header, 1x06, 1.27mm pitch, single row +Through hole pin header THT 1x06 1.27mm single row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 1.27mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 1.27mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Horizontal +Through hole angled pin header, 1x07, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x07 1.27mm single row +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Vertical +Through hole straight pin header, 1x07, 1.27mm pitch, single row +Through hole pin header THT 1x07 1.27mm single row +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 1.27mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 1.27mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Horizontal +Through hole angled pin header, 1x08, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x08 1.27mm single row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Vertical +Through hole straight pin header, 1x08, 1.27mm pitch, single row +Through hole pin header THT 1x08 1.27mm single row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 1.27mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 1.27mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Horizontal +Through hole angled pin header, 1x09, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x09 1.27mm single row +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Vertical +Through hole straight pin header, 1x09, 1.27mm pitch, single row +Through hole pin header THT 1x09 1.27mm single row +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 1.27mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 1.27mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Horizontal +Through hole angled pin header, 1x10, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x10 1.27mm single row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Vertical +Through hole straight pin header, 1x10, 1.27mm pitch, single row +Through hole pin header THT 1x10 1.27mm single row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 1.27mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 1.27mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Horizontal +Through hole angled pin header, 1x11, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x11 1.27mm single row +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Vertical +Through hole straight pin header, 1x11, 1.27mm pitch, single row +Through hole pin header THT 1x11 1.27mm single row +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 1.27mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 1.27mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Horizontal +Through hole angled pin header, 1x12, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x12 1.27mm single row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Vertical +Through hole straight pin header, 1x12, 1.27mm pitch, single row +Through hole pin header THT 1x12 1.27mm single row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 1.27mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 1.27mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Horizontal +Through hole angled pin header, 1x13, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x13 1.27mm single row +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Vertical +Through hole straight pin header, 1x13, 1.27mm pitch, single row +Through hole pin header THT 1x13 1.27mm single row +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 1.27mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 1.27mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Horizontal +Through hole angled pin header, 1x14, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x14 1.27mm single row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Vertical +Through hole straight pin header, 1x14, 1.27mm pitch, single row +Through hole pin header THT 1x14 1.27mm single row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 1.27mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 1.27mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Horizontal +Through hole angled pin header, 1x15, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x15 1.27mm single row +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Vertical +Through hole straight pin header, 1x15, 1.27mm pitch, single row +Through hole pin header THT 1x15 1.27mm single row +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 1.27mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 1.27mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Horizontal +Through hole angled pin header, 1x16, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x16 1.27mm single row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Vertical +Through hole straight pin header, 1x16, 1.27mm pitch, single row +Through hole pin header THT 1x16 1.27mm single row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 1.27mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 1.27mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Horizontal +Through hole angled pin header, 1x17, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x17 1.27mm single row +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Vertical +Through hole straight pin header, 1x17, 1.27mm pitch, single row +Through hole pin header THT 1x17 1.27mm single row +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 1.27mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 1.27mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Horizontal +Through hole angled pin header, 1x18, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x18 1.27mm single row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Vertical +Through hole straight pin header, 1x18, 1.27mm pitch, single row +Through hole pin header THT 1x18 1.27mm single row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 1.27mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 1.27mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Horizontal +Through hole angled pin header, 1x19, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x19 1.27mm single row +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Vertical +Through hole straight pin header, 1x19, 1.27mm pitch, single row +Through hole pin header THT 1x19 1.27mm single row +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 1.27mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 1.27mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Horizontal +Through hole angled pin header, 1x20, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x20 1.27mm single row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Vertical +Through hole straight pin header, 1x20, 1.27mm pitch, single row +Through hole pin header THT 1x20 1.27mm single row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 1.27mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 1.27mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Horizontal +Through hole angled pin header, 1x21, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x21 1.27mm single row +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Vertical +Through hole straight pin header, 1x21, 1.27mm pitch, single row +Through hole pin header THT 1x21 1.27mm single row +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 1.27mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 1.27mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Horizontal +Through hole angled pin header, 1x22, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x22 1.27mm single row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Vertical +Through hole straight pin header, 1x22, 1.27mm pitch, single row +Through hole pin header THT 1x22 1.27mm single row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 1.27mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 1.27mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Horizontal +Through hole angled pin header, 1x23, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x23 1.27mm single row +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Vertical +Through hole straight pin header, 1x23, 1.27mm pitch, single row +Through hole pin header THT 1x23 1.27mm single row +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 1.27mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 1.27mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Horizontal +Through hole angled pin header, 1x24, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x24 1.27mm single row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Vertical +Through hole straight pin header, 1x24, 1.27mm pitch, single row +Through hole pin header THT 1x24 1.27mm single row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 1.27mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 1.27mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Horizontal +Through hole angled pin header, 1x25, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x25 1.27mm single row +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Vertical +Through hole straight pin header, 1x25, 1.27mm pitch, single row +Through hole pin header THT 1x25 1.27mm single row +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 1.27mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 1.27mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Horizontal +Through hole angled pin header, 1x26, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x26 1.27mm single row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Vertical +Through hole straight pin header, 1x26, 1.27mm pitch, single row +Through hole pin header THT 1x26 1.27mm single row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 1.27mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 1.27mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Horizontal +Through hole angled pin header, 1x27, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x27 1.27mm single row +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Vertical +Through hole straight pin header, 1x27, 1.27mm pitch, single row +Through hole pin header THT 1x27 1.27mm single row +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 1.27mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 1.27mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Horizontal +Through hole angled pin header, 1x28, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x28 1.27mm single row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Vertical +Through hole straight pin header, 1x28, 1.27mm pitch, single row +Through hole pin header THT 1x28 1.27mm single row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 1.27mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 1.27mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Horizontal +Through hole angled pin header, 1x29, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x29 1.27mm single row +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Vertical +Through hole straight pin header, 1x29, 1.27mm pitch, single row +Through hole pin header THT 1x29 1.27mm single row +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 1.27mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 1.27mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Horizontal +Through hole angled pin header, 1x30, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x30 1.27mm single row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Vertical +Through hole straight pin header, 1x30, 1.27mm pitch, single row +Through hole pin header THT 1x30 1.27mm single row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 1.27mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 1.27mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Horizontal +Through hole angled pin header, 1x31, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x31 1.27mm single row +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Vertical +Through hole straight pin header, 1x31, 1.27mm pitch, single row +Through hole pin header THT 1x31 1.27mm single row +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 1.27mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 1.27mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Horizontal +Through hole angled pin header, 1x32, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x32 1.27mm single row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Vertical +Through hole straight pin header, 1x32, 1.27mm pitch, single row +Through hole pin header THT 1x32 1.27mm single row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 1.27mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 1.27mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Horizontal +Through hole angled pin header, 1x33, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x33 1.27mm single row +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Vertical +Through hole straight pin header, 1x33, 1.27mm pitch, single row +Through hole pin header THT 1x33 1.27mm single row +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 1.27mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 1.27mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Horizontal +Through hole angled pin header, 1x34, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x34 1.27mm single row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Vertical +Through hole straight pin header, 1x34, 1.27mm pitch, single row +Through hole pin header THT 1x34 1.27mm single row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 1.27mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 1.27mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Horizontal +Through hole angled pin header, 1x35, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x35 1.27mm single row +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Vertical +Through hole straight pin header, 1x35, 1.27mm pitch, single row +Through hole pin header THT 1x35 1.27mm single row +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 1.27mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 1.27mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Horizontal +Through hole angled pin header, 1x36, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x36 1.27mm single row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Vertical +Through hole straight pin header, 1x36, 1.27mm pitch, single row +Through hole pin header THT 1x36 1.27mm single row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 1.27mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 1.27mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Horizontal +Through hole angled pin header, 1x37, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x37 1.27mm single row +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Vertical +Through hole straight pin header, 1x37, 1.27mm pitch, single row +Through hole pin header THT 1x37 1.27mm single row +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 1.27mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 1.27mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Horizontal +Through hole angled pin header, 1x38, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x38 1.27mm single row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Vertical +Through hole straight pin header, 1x38, 1.27mm pitch, single row +Through hole pin header THT 1x38 1.27mm single row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 1.27mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 1.27mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Horizontal +Through hole angled pin header, 1x39, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x39 1.27mm single row +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Vertical +Through hole straight pin header, 1x39, 1.27mm pitch, single row +Through hole pin header THT 1x39 1.27mm single row +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 1.27mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 1.27mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Horizontal +Through hole angled pin header, 1x40, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x40 1.27mm single row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Vertical +Through hole straight pin header, 1x40, 1.27mm pitch, single row +Through hole pin header THT 1x40 1.27mm single row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 1.27mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 1.27mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x01_P1.27mm_Horizontal +Through hole angled pin header, 2x01, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x01 1.27mm double row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_2x01_P1.27mm_Vertical +Through hole straight pin header, 2x01, 1.27mm pitch, double rows +Through hole pin header THT 2x01 1.27mm double row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_2x01_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x01 1.27mm double row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_2x02_P1.27mm_Horizontal +Through hole angled pin header, 2x02, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x02 1.27mm double row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_2x02_P1.27mm_Vertical +Through hole straight pin header, 2x02, 1.27mm pitch, double rows +Through hole pin header THT 2x02 1.27mm double row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_2x02_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x02 1.27mm double row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_2x03_P1.27mm_Horizontal +Through hole angled pin header, 2x03, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_2x03_P1.27mm_Vertical +Through hole straight pin header, 2x03, 1.27mm pitch, double rows +Through hole pin header THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_2x03_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x03 1.27mm double row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_2x04_P1.27mm_Horizontal +Through hole angled pin header, 2x04, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_2x04_P1.27mm_Vertical +Through hole straight pin header, 2x04, 1.27mm pitch, double rows +Through hole pin header THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_2x04_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x04 1.27mm double row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_2x05_P1.27mm_Horizontal +Through hole angled pin header, 2x05, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_2x05_P1.27mm_Vertical +Through hole straight pin header, 2x05, 1.27mm pitch, double rows +Through hole pin header THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_2x05_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x05 1.27mm double row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_2x06_P1.27mm_Horizontal +Through hole angled pin header, 2x06, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_2x06_P1.27mm_Vertical +Through hole straight pin header, 2x06, 1.27mm pitch, double rows +Through hole pin header THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_2x06_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x06 1.27mm double row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_2x07_P1.27mm_Horizontal +Through hole angled pin header, 2x07, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_2x07_P1.27mm_Vertical +Through hole straight pin header, 2x07, 1.27mm pitch, double rows +Through hole pin header THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_2x07_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x07 1.27mm double row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_2x08_P1.27mm_Horizontal +Through hole angled pin header, 2x08, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_2x08_P1.27mm_Vertical +Through hole straight pin header, 2x08, 1.27mm pitch, double rows +Through hole pin header THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_2x08_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x08 1.27mm double row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_2x09_P1.27mm_Horizontal +Through hole angled pin header, 2x09, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_2x09_P1.27mm_Vertical +Through hole straight pin header, 2x09, 1.27mm pitch, double rows +Through hole pin header THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_2x09_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x09 1.27mm double row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_2x10_P1.27mm_Horizontal +Through hole angled pin header, 2x10, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_2x10_P1.27mm_Vertical +Through hole straight pin header, 2x10, 1.27mm pitch, double rows +Through hole pin header THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_2x10_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x10 1.27mm double row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_2x11_P1.27mm_Horizontal +Through hole angled pin header, 2x11, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_2x11_P1.27mm_Vertical +Through hole straight pin header, 2x11, 1.27mm pitch, double rows +Through hole pin header THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_2x11_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x11 1.27mm double row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_2x12_P1.27mm_Horizontal +Through hole angled pin header, 2x12, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_2x12_P1.27mm_Vertical +Through hole straight pin header, 2x12, 1.27mm pitch, double rows +Through hole pin header THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_2x12_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x12 1.27mm double row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_2x13_P1.27mm_Horizontal +Through hole angled pin header, 2x13, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_2x13_P1.27mm_Vertical +Through hole straight pin header, 2x13, 1.27mm pitch, double rows +Through hole pin header THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_2x13_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x13 1.27mm double row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_2x14_P1.27mm_Horizontal +Through hole angled pin header, 2x14, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_2x14_P1.27mm_Vertical +Through hole straight pin header, 2x14, 1.27mm pitch, double rows +Through hole pin header THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_2x14_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x14 1.27mm double row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_2x15_P1.27mm_Horizontal +Through hole angled pin header, 2x15, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_2x15_P1.27mm_Vertical +Through hole straight pin header, 2x15, 1.27mm pitch, double rows +Through hole pin header THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_2x15_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x15 1.27mm double row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_2x16_P1.27mm_Horizontal +Through hole angled pin header, 2x16, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_2x16_P1.27mm_Vertical +Through hole straight pin header, 2x16, 1.27mm pitch, double rows +Through hole pin header THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_2x16_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x16 1.27mm double row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_2x17_P1.27mm_Horizontal +Through hole angled pin header, 2x17, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_2x17_P1.27mm_Vertical +Through hole straight pin header, 2x17, 1.27mm pitch, double rows +Through hole pin header THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_2x17_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x17 1.27mm double row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_2x18_P1.27mm_Horizontal +Through hole angled pin header, 2x18, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_2x18_P1.27mm_Vertical +Through hole straight pin header, 2x18, 1.27mm pitch, double rows +Through hole pin header THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_2x18_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x18 1.27mm double row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_2x19_P1.27mm_Horizontal +Through hole angled pin header, 2x19, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_2x19_P1.27mm_Vertical +Through hole straight pin header, 2x19, 1.27mm pitch, double rows +Through hole pin header THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_2x19_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x19 1.27mm double row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_2x20_P1.27mm_Horizontal +Through hole angled pin header, 2x20, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x20_P1.27mm_Vertical +Through hole straight pin header, 2x20, 1.27mm pitch, double rows +Through hole pin header THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x20_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x20 1.27mm double row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x21_P1.27mm_Horizontal +Through hole angled pin header, 2x21, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinHeader_1.27mm +PinHeader_2x21_P1.27mm_Vertical +Through hole straight pin header, 2x21, 1.27mm pitch, double rows +Through hole pin header THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinHeader_1.27mm +PinHeader_2x21_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x21 1.27mm double row +0 +42 +42 +Connector_PinHeader_1.27mm +PinHeader_2x22_P1.27mm_Horizontal +Through hole angled pin header, 2x22, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinHeader_1.27mm +PinHeader_2x22_P1.27mm_Vertical +Through hole straight pin header, 2x22, 1.27mm pitch, double rows +Through hole pin header THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinHeader_1.27mm +PinHeader_2x22_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x22 1.27mm double row +0 +44 +44 +Connector_PinHeader_1.27mm +PinHeader_2x23_P1.27mm_Horizontal +Through hole angled pin header, 2x23, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinHeader_1.27mm +PinHeader_2x23_P1.27mm_Vertical +Through hole straight pin header, 2x23, 1.27mm pitch, double rows +Through hole pin header THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinHeader_1.27mm +PinHeader_2x23_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x23 1.27mm double row +0 +46 +46 +Connector_PinHeader_1.27mm +PinHeader_2x24_P1.27mm_Horizontal +Through hole angled pin header, 2x24, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinHeader_1.27mm +PinHeader_2x24_P1.27mm_Vertical +Through hole straight pin header, 2x24, 1.27mm pitch, double rows +Through hole pin header THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinHeader_1.27mm +PinHeader_2x24_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x24 1.27mm double row +0 +48 +48 +Connector_PinHeader_1.27mm +PinHeader_2x25_P1.27mm_Horizontal +Through hole angled pin header, 2x25, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinHeader_1.27mm +PinHeader_2x25_P1.27mm_Vertical +Through hole straight pin header, 2x25, 1.27mm pitch, double rows +Through hole pin header THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinHeader_1.27mm +PinHeader_2x25_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x25 1.27mm double row +0 +50 +50 +Connector_PinHeader_1.27mm +PinHeader_2x26_P1.27mm_Horizontal +Through hole angled pin header, 2x26, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinHeader_1.27mm +PinHeader_2x26_P1.27mm_Vertical +Through hole straight pin header, 2x26, 1.27mm pitch, double rows +Through hole pin header THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinHeader_1.27mm +PinHeader_2x26_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x26 1.27mm double row +0 +52 +52 +Connector_PinHeader_1.27mm +PinHeader_2x27_P1.27mm_Horizontal +Through hole angled pin header, 2x27, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinHeader_1.27mm +PinHeader_2x27_P1.27mm_Vertical +Through hole straight pin header, 2x27, 1.27mm pitch, double rows +Through hole pin header THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinHeader_1.27mm +PinHeader_2x27_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x27 1.27mm double row +0 +54 +54 +Connector_PinHeader_1.27mm +PinHeader_2x28_P1.27mm_Horizontal +Through hole angled pin header, 2x28, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinHeader_1.27mm +PinHeader_2x28_P1.27mm_Vertical +Through hole straight pin header, 2x28, 1.27mm pitch, double rows +Through hole pin header THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinHeader_1.27mm +PinHeader_2x28_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x28 1.27mm double row +0 +56 +56 +Connector_PinHeader_1.27mm +PinHeader_2x29_P1.27mm_Horizontal +Through hole angled pin header, 2x29, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinHeader_1.27mm +PinHeader_2x29_P1.27mm_Vertical +Through hole straight pin header, 2x29, 1.27mm pitch, double rows +Through hole pin header THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinHeader_1.27mm +PinHeader_2x29_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x29 1.27mm double row +0 +58 +58 +Connector_PinHeader_1.27mm +PinHeader_2x30_P1.27mm_Horizontal +Through hole angled pin header, 2x30, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinHeader_1.27mm +PinHeader_2x30_P1.27mm_Vertical +Through hole straight pin header, 2x30, 1.27mm pitch, double rows +Through hole pin header THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinHeader_1.27mm +PinHeader_2x30_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x30 1.27mm double row +0 +60 +60 +Connector_PinHeader_1.27mm +PinHeader_2x31_P1.27mm_Horizontal +Through hole angled pin header, 2x31, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinHeader_1.27mm +PinHeader_2x31_P1.27mm_Vertical +Through hole straight pin header, 2x31, 1.27mm pitch, double rows +Through hole pin header THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinHeader_1.27mm +PinHeader_2x31_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x31 1.27mm double row +0 +62 +62 +Connector_PinHeader_1.27mm +PinHeader_2x32_P1.27mm_Horizontal +Through hole angled pin header, 2x32, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinHeader_1.27mm +PinHeader_2x32_P1.27mm_Vertical +Through hole straight pin header, 2x32, 1.27mm pitch, double rows +Through hole pin header THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinHeader_1.27mm +PinHeader_2x32_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x32 1.27mm double row +0 +64 +64 +Connector_PinHeader_1.27mm +PinHeader_2x33_P1.27mm_Horizontal +Through hole angled pin header, 2x33, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinHeader_1.27mm +PinHeader_2x33_P1.27mm_Vertical +Through hole straight pin header, 2x33, 1.27mm pitch, double rows +Through hole pin header THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinHeader_1.27mm +PinHeader_2x33_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x33 1.27mm double row +0 +66 +66 +Connector_PinHeader_1.27mm +PinHeader_2x34_P1.27mm_Horizontal +Through hole angled pin header, 2x34, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinHeader_1.27mm +PinHeader_2x34_P1.27mm_Vertical +Through hole straight pin header, 2x34, 1.27mm pitch, double rows +Through hole pin header THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinHeader_1.27mm +PinHeader_2x34_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x34 1.27mm double row +0 +68 +68 +Connector_PinHeader_1.27mm +PinHeader_2x35_P1.27mm_Horizontal +Through hole angled pin header, 2x35, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinHeader_1.27mm +PinHeader_2x35_P1.27mm_Vertical +Through hole straight pin header, 2x35, 1.27mm pitch, double rows +Through hole pin header THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinHeader_1.27mm +PinHeader_2x35_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x35 1.27mm double row +0 +70 +70 +Connector_PinHeader_1.27mm +PinHeader_2x36_P1.27mm_Horizontal +Through hole angled pin header, 2x36, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinHeader_1.27mm +PinHeader_2x36_P1.27mm_Vertical +Through hole straight pin header, 2x36, 1.27mm pitch, double rows +Through hole pin header THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinHeader_1.27mm +PinHeader_2x36_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x36 1.27mm double row +0 +72 +72 +Connector_PinHeader_1.27mm +PinHeader_2x37_P1.27mm_Horizontal +Through hole angled pin header, 2x37, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinHeader_1.27mm +PinHeader_2x37_P1.27mm_Vertical +Through hole straight pin header, 2x37, 1.27mm pitch, double rows +Through hole pin header THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinHeader_1.27mm +PinHeader_2x37_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x37 1.27mm double row +0 +74 +74 +Connector_PinHeader_1.27mm +PinHeader_2x38_P1.27mm_Horizontal +Through hole angled pin header, 2x38, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinHeader_1.27mm +PinHeader_2x38_P1.27mm_Vertical +Through hole straight pin header, 2x38, 1.27mm pitch, double rows +Through hole pin header THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinHeader_1.27mm +PinHeader_2x38_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x38 1.27mm double row +0 +76 +76 +Connector_PinHeader_1.27mm +PinHeader_2x39_P1.27mm_Horizontal +Through hole angled pin header, 2x39, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinHeader_1.27mm +PinHeader_2x39_P1.27mm_Vertical +Through hole straight pin header, 2x39, 1.27mm pitch, double rows +Through hole pin header THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinHeader_1.27mm +PinHeader_2x39_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x39 1.27mm double row +0 +78 +78 +Connector_PinHeader_1.27mm +PinHeader_2x40_P1.27mm_Horizontal +Through hole angled pin header, 2x40, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinHeader_1.27mm +PinHeader_2x40_P1.27mm_Vertical +Through hole straight pin header, 2x40, 1.27mm pitch, double rows +Through hole pin header THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinHeader_1.27mm +PinHeader_2x40_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x40 1.27mm double row +0 +80 +80 +Connector_PinHeader_2.00mm +PinHeader_1x01_P2.00mm_Horizontal +Through hole angled pin header, 1x01, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinHeader_2.00mm +PinHeader_1x01_P2.00mm_Vertical +Through hole straight pin header, 1x01, 2.00mm pitch, single row +Through hole pin header THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Horizontal +Through hole angled pin header, 1x02, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Vertical +Through hole straight pin header, 1x02, 2.00mm pitch, single row +Through hole pin header THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 2.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 2.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Horizontal +Through hole angled pin header, 1x03, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Vertical +Through hole straight pin header, 1x03, 2.00mm pitch, single row +Through hole pin header THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 2.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 2.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Horizontal +Through hole angled pin header, 1x04, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Vertical +Through hole straight pin header, 1x04, 2.00mm pitch, single row +Through hole pin header THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 2.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 2.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Horizontal +Through hole angled pin header, 1x05, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Vertical +Through hole straight pin header, 1x05, 2.00mm pitch, single row +Through hole pin header THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 2.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 2.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Horizontal +Through hole angled pin header, 1x06, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Vertical +Through hole straight pin header, 1x06, 2.00mm pitch, single row +Through hole pin header THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 2.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 2.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Horizontal +Through hole angled pin header, 1x07, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Vertical +Through hole straight pin header, 1x07, 2.00mm pitch, single row +Through hole pin header THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 2.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 2.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Horizontal +Through hole angled pin header, 1x08, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Vertical +Through hole straight pin header, 1x08, 2.00mm pitch, single row +Through hole pin header THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 2.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 2.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Horizontal +Through hole angled pin header, 1x09, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Vertical +Through hole straight pin header, 1x09, 2.00mm pitch, single row +Through hole pin header THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 2.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 2.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Horizontal +Through hole angled pin header, 1x10, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Vertical +Through hole straight pin header, 1x10, 2.00mm pitch, single row +Through hole pin header THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 2.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 2.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Horizontal +Through hole angled pin header, 1x11, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Vertical +Through hole straight pin header, 1x11, 2.00mm pitch, single row +Through hole pin header THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 2.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 2.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Horizontal +Through hole angled pin header, 1x12, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Vertical +Through hole straight pin header, 1x12, 2.00mm pitch, single row +Through hole pin header THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 2.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 2.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Horizontal +Through hole angled pin header, 1x13, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Vertical +Through hole straight pin header, 1x13, 2.00mm pitch, single row +Through hole pin header THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 2.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 2.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Horizontal +Through hole angled pin header, 1x14, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Vertical +Through hole straight pin header, 1x14, 2.00mm pitch, single row +Through hole pin header THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 2.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 2.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Horizontal +Through hole angled pin header, 1x15, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Vertical +Through hole straight pin header, 1x15, 2.00mm pitch, single row +Through hole pin header THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 2.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 2.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Horizontal +Through hole angled pin header, 1x16, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Vertical +Through hole straight pin header, 1x16, 2.00mm pitch, single row +Through hole pin header THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 2.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 2.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Horizontal +Through hole angled pin header, 1x17, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Vertical +Through hole straight pin header, 1x17, 2.00mm pitch, single row +Through hole pin header THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 2.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 2.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Horizontal +Through hole angled pin header, 1x18, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Vertical +Through hole straight pin header, 1x18, 2.00mm pitch, single row +Through hole pin header THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 2.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 2.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Horizontal +Through hole angled pin header, 1x19, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Vertical +Through hole straight pin header, 1x19, 2.00mm pitch, single row +Through hole pin header THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 2.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 2.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Horizontal +Through hole angled pin header, 1x20, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Vertical +Through hole straight pin header, 1x20, 2.00mm pitch, single row +Through hole pin header THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 2.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 2.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Horizontal +Through hole angled pin header, 1x21, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Vertical +Through hole straight pin header, 1x21, 2.00mm pitch, single row +Through hole pin header THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 2.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 2.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Horizontal +Through hole angled pin header, 1x22, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Vertical +Through hole straight pin header, 1x22, 2.00mm pitch, single row +Through hole pin header THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 2.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 2.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Horizontal +Through hole angled pin header, 1x23, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Vertical +Through hole straight pin header, 1x23, 2.00mm pitch, single row +Through hole pin header THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 2.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 2.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Horizontal +Through hole angled pin header, 1x24, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Vertical +Through hole straight pin header, 1x24, 2.00mm pitch, single row +Through hole pin header THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 2.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 2.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Horizontal +Through hole angled pin header, 1x25, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Vertical +Through hole straight pin header, 1x25, 2.00mm pitch, single row +Through hole pin header THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 2.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 2.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Horizontal +Through hole angled pin header, 1x26, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Vertical +Through hole straight pin header, 1x26, 2.00mm pitch, single row +Through hole pin header THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 2.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 2.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Horizontal +Through hole angled pin header, 1x27, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Vertical +Through hole straight pin header, 1x27, 2.00mm pitch, single row +Through hole pin header THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 2.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 2.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Horizontal +Through hole angled pin header, 1x28, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Vertical +Through hole straight pin header, 1x28, 2.00mm pitch, single row +Through hole pin header THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 2.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 2.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Horizontal +Through hole angled pin header, 1x29, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Vertical +Through hole straight pin header, 1x29, 2.00mm pitch, single row +Through hole pin header THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 2.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 2.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Horizontal +Through hole angled pin header, 1x30, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Vertical +Through hole straight pin header, 1x30, 2.00mm pitch, single row +Through hole pin header THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 2.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 2.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Horizontal +Through hole angled pin header, 1x31, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Vertical +Through hole straight pin header, 1x31, 2.00mm pitch, single row +Through hole pin header THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 2.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 2.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Horizontal +Through hole angled pin header, 1x32, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Vertical +Through hole straight pin header, 1x32, 2.00mm pitch, single row +Through hole pin header THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 2.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 2.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Horizontal +Through hole angled pin header, 1x33, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Vertical +Through hole straight pin header, 1x33, 2.00mm pitch, single row +Through hole pin header THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 2.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 2.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Horizontal +Through hole angled pin header, 1x34, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Vertical +Through hole straight pin header, 1x34, 2.00mm pitch, single row +Through hole pin header THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 2.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 2.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Horizontal +Through hole angled pin header, 1x35, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Vertical +Through hole straight pin header, 1x35, 2.00mm pitch, single row +Through hole pin header THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 2.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 2.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Horizontal +Through hole angled pin header, 1x36, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Vertical +Through hole straight pin header, 1x36, 2.00mm pitch, single row +Through hole pin header THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 2.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 2.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Horizontal +Through hole angled pin header, 1x37, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Vertical +Through hole straight pin header, 1x37, 2.00mm pitch, single row +Through hole pin header THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 2.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 2.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Horizontal +Through hole angled pin header, 1x38, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Vertical +Through hole straight pin header, 1x38, 2.00mm pitch, single row +Through hole pin header THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 2.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 2.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Horizontal +Through hole angled pin header, 1x39, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Vertical +Through hole straight pin header, 1x39, 2.00mm pitch, single row +Through hole pin header THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 2.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 2.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Horizontal +Through hole angled pin header, 1x40, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Vertical +Through hole straight pin header, 1x40, 2.00mm pitch, single row +Through hole pin header THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 2.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 2.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x01_P2.00mm_Horizontal +Through hole angled pin header, 2x01, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_2x01_P2.00mm_Vertical +Through hole straight pin header, 2x01, 2.00mm pitch, double rows +Through hole pin header THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_2x01_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x01 2.00mm double row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_2x02_P2.00mm_Horizontal +Through hole angled pin header, 2x02, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_2x02_P2.00mm_Vertical +Through hole straight pin header, 2x02, 2.00mm pitch, double rows +Through hole pin header THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_2x02_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x02 2.00mm double row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_2x03_P2.00mm_Horizontal +Through hole angled pin header, 2x03, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_2x03_P2.00mm_Vertical +Through hole straight pin header, 2x03, 2.00mm pitch, double rows +Through hole pin header THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_2x03_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x03 2.00mm double row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_2x04_P2.00mm_Horizontal +Through hole angled pin header, 2x04, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_2x04_P2.00mm_Vertical +Through hole straight pin header, 2x04, 2.00mm pitch, double rows +Through hole pin header THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_2x04_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x04 2.00mm double row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_2x05_P2.00mm_Horizontal +Through hole angled pin header, 2x05, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_2x05_P2.00mm_Vertical +Through hole straight pin header, 2x05, 2.00mm pitch, double rows +Through hole pin header THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_2x05_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x05 2.00mm double row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_2x06_P2.00mm_Horizontal +Through hole angled pin header, 2x06, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_2x06_P2.00mm_Vertical +Through hole straight pin header, 2x06, 2.00mm pitch, double rows +Through hole pin header THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_2x06_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x06 2.00mm double row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_2x07_P2.00mm_Horizontal +Through hole angled pin header, 2x07, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_2x07_P2.00mm_Vertical +Through hole straight pin header, 2x07, 2.00mm pitch, double rows +Through hole pin header THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_2x07_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x07 2.00mm double row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_2x08_P2.00mm_Horizontal +Through hole angled pin header, 2x08, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_2x08_P2.00mm_Vertical +Through hole straight pin header, 2x08, 2.00mm pitch, double rows +Through hole pin header THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_2x08_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x08 2.00mm double row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_2x09_P2.00mm_Horizontal +Through hole angled pin header, 2x09, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_2x09_P2.00mm_Vertical +Through hole straight pin header, 2x09, 2.00mm pitch, double rows +Through hole pin header THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_2x09_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x09 2.00mm double row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_2x10_P2.00mm_Horizontal +Through hole angled pin header, 2x10, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_2x10_P2.00mm_Vertical +Through hole straight pin header, 2x10, 2.00mm pitch, double rows +Through hole pin header THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_2x10_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x10 2.00mm double row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_2x11_P2.00mm_Horizontal +Through hole angled pin header, 2x11, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_2x11_P2.00mm_Vertical +Through hole straight pin header, 2x11, 2.00mm pitch, double rows +Through hole pin header THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_2x11_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x11 2.00mm double row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_2x12_P2.00mm_Horizontal +Through hole angled pin header, 2x12, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_2x12_P2.00mm_Vertical +Through hole straight pin header, 2x12, 2.00mm pitch, double rows +Through hole pin header THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_2x12_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x12 2.00mm double row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_2x13_P2.00mm_Horizontal +Through hole angled pin header, 2x13, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_2x13_P2.00mm_Vertical +Through hole straight pin header, 2x13, 2.00mm pitch, double rows +Through hole pin header THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_2x13_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x13 2.00mm double row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_2x14_P2.00mm_Horizontal +Through hole angled pin header, 2x14, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_2x14_P2.00mm_Vertical +Through hole straight pin header, 2x14, 2.00mm pitch, double rows +Through hole pin header THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_2x14_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x14 2.00mm double row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_2x15_P2.00mm_Horizontal +Through hole angled pin header, 2x15, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_2x15_P2.00mm_Vertical +Through hole straight pin header, 2x15, 2.00mm pitch, double rows +Through hole pin header THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_2x15_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x15 2.00mm double row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_2x16_P2.00mm_Horizontal +Through hole angled pin header, 2x16, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_2x16_P2.00mm_Vertical +Through hole straight pin header, 2x16, 2.00mm pitch, double rows +Through hole pin header THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_2x16_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x16 2.00mm double row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_2x17_P2.00mm_Horizontal +Through hole angled pin header, 2x17, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_2x17_P2.00mm_Vertical +Through hole straight pin header, 2x17, 2.00mm pitch, double rows +Through hole pin header THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_2x17_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x17 2.00mm double row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_2x18_P2.00mm_Horizontal +Through hole angled pin header, 2x18, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_2x18_P2.00mm_Vertical +Through hole straight pin header, 2x18, 2.00mm pitch, double rows +Through hole pin header THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_2x18_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x18 2.00mm double row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_2x19_P2.00mm_Horizontal +Through hole angled pin header, 2x19, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_2x19_P2.00mm_Vertical +Through hole straight pin header, 2x19, 2.00mm pitch, double rows +Through hole pin header THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_2x19_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x19 2.00mm double row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_2x20_P2.00mm_Horizontal +Through hole angled pin header, 2x20, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x20_P2.00mm_Vertical +Through hole straight pin header, 2x20, 2.00mm pitch, double rows +Through hole pin header THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x20_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x20 2.00mm double row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x21_P2.00mm_Horizontal +Through hole angled pin header, 2x21, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinHeader_2.00mm +PinHeader_2x21_P2.00mm_Vertical +Through hole straight pin header, 2x21, 2.00mm pitch, double rows +Through hole pin header THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinHeader_2.00mm +PinHeader_2x21_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x21 2.00mm double row +0 +42 +42 +Connector_PinHeader_2.00mm +PinHeader_2x22_P2.00mm_Horizontal +Through hole angled pin header, 2x22, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinHeader_2.00mm +PinHeader_2x22_P2.00mm_Vertical +Through hole straight pin header, 2x22, 2.00mm pitch, double rows +Through hole pin header THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinHeader_2.00mm +PinHeader_2x22_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x22 2.00mm double row +0 +44 +44 +Connector_PinHeader_2.00mm +PinHeader_2x23_P2.00mm_Horizontal +Through hole angled pin header, 2x23, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinHeader_2.00mm +PinHeader_2x23_P2.00mm_Vertical +Through hole straight pin header, 2x23, 2.00mm pitch, double rows +Through hole pin header THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinHeader_2.00mm +PinHeader_2x23_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x23 2.00mm double row +0 +46 +46 +Connector_PinHeader_2.00mm +PinHeader_2x24_P2.00mm_Horizontal +Through hole angled pin header, 2x24, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinHeader_2.00mm +PinHeader_2x24_P2.00mm_Vertical +Through hole straight pin header, 2x24, 2.00mm pitch, double rows +Through hole pin header THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinHeader_2.00mm +PinHeader_2x24_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x24 2.00mm double row +0 +48 +48 +Connector_PinHeader_2.00mm +PinHeader_2x25_P2.00mm_Horizontal +Through hole angled pin header, 2x25, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinHeader_2.00mm +PinHeader_2x25_P2.00mm_Vertical +Through hole straight pin header, 2x25, 2.00mm pitch, double rows +Through hole pin header THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinHeader_2.00mm +PinHeader_2x25_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x25 2.00mm double row +0 +50 +50 +Connector_PinHeader_2.00mm +PinHeader_2x26_P2.00mm_Horizontal +Through hole angled pin header, 2x26, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinHeader_2.00mm +PinHeader_2x26_P2.00mm_Vertical +Through hole straight pin header, 2x26, 2.00mm pitch, double rows +Through hole pin header THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinHeader_2.00mm +PinHeader_2x26_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x26 2.00mm double row +0 +52 +52 +Connector_PinHeader_2.00mm +PinHeader_2x27_P2.00mm_Horizontal +Through hole angled pin header, 2x27, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinHeader_2.00mm +PinHeader_2x27_P2.00mm_Vertical +Through hole straight pin header, 2x27, 2.00mm pitch, double rows +Through hole pin header THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinHeader_2.00mm +PinHeader_2x27_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x27 2.00mm double row +0 +54 +54 +Connector_PinHeader_2.00mm +PinHeader_2x28_P2.00mm_Horizontal +Through hole angled pin header, 2x28, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinHeader_2.00mm +PinHeader_2x28_P2.00mm_Vertical +Through hole straight pin header, 2x28, 2.00mm pitch, double rows +Through hole pin header THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinHeader_2.00mm +PinHeader_2x28_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x28 2.00mm double row +0 +56 +56 +Connector_PinHeader_2.00mm +PinHeader_2x29_P2.00mm_Horizontal +Through hole angled pin header, 2x29, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinHeader_2.00mm +PinHeader_2x29_P2.00mm_Vertical +Through hole straight pin header, 2x29, 2.00mm pitch, double rows +Through hole pin header THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinHeader_2.00mm +PinHeader_2x29_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x29 2.00mm double row +0 +58 +58 +Connector_PinHeader_2.00mm +PinHeader_2x30_P2.00mm_Horizontal +Through hole angled pin header, 2x30, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinHeader_2.00mm +PinHeader_2x30_P2.00mm_Vertical +Through hole straight pin header, 2x30, 2.00mm pitch, double rows +Through hole pin header THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinHeader_2.00mm +PinHeader_2x30_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x30 2.00mm double row +0 +60 +60 +Connector_PinHeader_2.00mm +PinHeader_2x31_P2.00mm_Horizontal +Through hole angled pin header, 2x31, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinHeader_2.00mm +PinHeader_2x31_P2.00mm_Vertical +Through hole straight pin header, 2x31, 2.00mm pitch, double rows +Through hole pin header THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinHeader_2.00mm +PinHeader_2x31_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x31 2.00mm double row +0 +62 +62 +Connector_PinHeader_2.00mm +PinHeader_2x32_P2.00mm_Horizontal +Through hole angled pin header, 2x32, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinHeader_2.00mm +PinHeader_2x32_P2.00mm_Vertical +Through hole straight pin header, 2x32, 2.00mm pitch, double rows +Through hole pin header THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinHeader_2.00mm +PinHeader_2x32_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x32 2.00mm double row +0 +64 +64 +Connector_PinHeader_2.00mm +PinHeader_2x33_P2.00mm_Horizontal +Through hole angled pin header, 2x33, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinHeader_2.00mm +PinHeader_2x33_P2.00mm_Vertical +Through hole straight pin header, 2x33, 2.00mm pitch, double rows +Through hole pin header THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinHeader_2.00mm +PinHeader_2x33_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x33 2.00mm double row +0 +66 +66 +Connector_PinHeader_2.00mm +PinHeader_2x34_P2.00mm_Horizontal +Through hole angled pin header, 2x34, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinHeader_2.00mm +PinHeader_2x34_P2.00mm_Vertical +Through hole straight pin header, 2x34, 2.00mm pitch, double rows +Through hole pin header THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinHeader_2.00mm +PinHeader_2x34_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x34 2.00mm double row +0 +68 +68 +Connector_PinHeader_2.00mm +PinHeader_2x35_P2.00mm_Horizontal +Through hole angled pin header, 2x35, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinHeader_2.00mm +PinHeader_2x35_P2.00mm_Vertical +Through hole straight pin header, 2x35, 2.00mm pitch, double rows +Through hole pin header THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinHeader_2.00mm +PinHeader_2x35_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x35 2.00mm double row +0 +70 +70 +Connector_PinHeader_2.00mm +PinHeader_2x36_P2.00mm_Horizontal +Through hole angled pin header, 2x36, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinHeader_2.00mm +PinHeader_2x36_P2.00mm_Vertical +Through hole straight pin header, 2x36, 2.00mm pitch, double rows +Through hole pin header THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinHeader_2.00mm +PinHeader_2x36_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x36 2.00mm double row +0 +72 +72 +Connector_PinHeader_2.00mm +PinHeader_2x37_P2.00mm_Horizontal +Through hole angled pin header, 2x37, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinHeader_2.00mm +PinHeader_2x37_P2.00mm_Vertical +Through hole straight pin header, 2x37, 2.00mm pitch, double rows +Through hole pin header THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinHeader_2.00mm +PinHeader_2x37_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x37 2.00mm double row +0 +74 +74 +Connector_PinHeader_2.00mm +PinHeader_2x38_P2.00mm_Horizontal +Through hole angled pin header, 2x38, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinHeader_2.00mm +PinHeader_2x38_P2.00mm_Vertical +Through hole straight pin header, 2x38, 2.00mm pitch, double rows +Through hole pin header THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinHeader_2.00mm +PinHeader_2x38_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x38 2.00mm double row +0 +76 +76 +Connector_PinHeader_2.00mm +PinHeader_2x39_P2.00mm_Horizontal +Through hole angled pin header, 2x39, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinHeader_2.00mm +PinHeader_2x39_P2.00mm_Vertical +Through hole straight pin header, 2x39, 2.00mm pitch, double rows +Through hole pin header THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinHeader_2.00mm +PinHeader_2x39_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x39 2.00mm double row +0 +78 +78 +Connector_PinHeader_2.00mm +PinHeader_2x40_P2.00mm_Horizontal +Through hole angled pin header, 2x40, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinHeader_2.00mm +PinHeader_2x40_P2.00mm_Vertical +Through hole straight pin header, 2x40, 2.00mm pitch, double rows +Through hole pin header THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinHeader_2.00mm +PinHeader_2x40_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x40 2.00mm double row +0 +80 +80 +Connector_PinHeader_2.54mm +PinHeader_1x01_P2.54mm_Horizontal +Through hole angled pin header, 1x01, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinHeader_2.54mm +PinHeader_1x01_P2.54mm_Vertical +Through hole straight pin header, 1x01, 2.54mm pitch, single row +Through hole pin header THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Horizontal +Through hole angled pin header, 1x02, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Vertical +Through hole straight pin header, 1x02, 2.54mm pitch, single row +Through hole pin header THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 2.54mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 2.54mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Horizontal +Through hole angled pin header, 1x03, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Vertical +Through hole straight pin header, 1x03, 2.54mm pitch, single row +Through hole pin header THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 2.54mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 2.54mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Horizontal +Through hole angled pin header, 1x04, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Vertical +Through hole straight pin header, 1x04, 2.54mm pitch, single row +Through hole pin header THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 2.54mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 2.54mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Horizontal +Through hole angled pin header, 1x05, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Vertical +Through hole straight pin header, 1x05, 2.54mm pitch, single row +Through hole pin header THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 2.54mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 2.54mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Horizontal +Through hole angled pin header, 1x06, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Vertical +Through hole straight pin header, 1x06, 2.54mm pitch, single row +Through hole pin header THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 2.54mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 2.54mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Horizontal +Through hole angled pin header, 1x07, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Vertical +Through hole straight pin header, 1x07, 2.54mm pitch, single row +Through hole pin header THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 2.54mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 2.54mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Horizontal +Through hole angled pin header, 1x08, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Vertical +Through hole straight pin header, 1x08, 2.54mm pitch, single row +Through hole pin header THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 2.54mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 2.54mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Horizontal +Through hole angled pin header, 1x09, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Vertical +Through hole straight pin header, 1x09, 2.54mm pitch, single row +Through hole pin header THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 2.54mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 2.54mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Horizontal +Through hole angled pin header, 1x10, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Vertical +Through hole straight pin header, 1x10, 2.54mm pitch, single row +Through hole pin header THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 2.54mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 2.54mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Horizontal +Through hole angled pin header, 1x11, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Vertical +Through hole straight pin header, 1x11, 2.54mm pitch, single row +Through hole pin header THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 2.54mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 2.54mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Horizontal +Through hole angled pin header, 1x12, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Vertical +Through hole straight pin header, 1x12, 2.54mm pitch, single row +Through hole pin header THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 2.54mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 2.54mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Horizontal +Through hole angled pin header, 1x13, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Vertical +Through hole straight pin header, 1x13, 2.54mm pitch, single row +Through hole pin header THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 2.54mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 2.54mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Horizontal +Through hole angled pin header, 1x14, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Vertical +Through hole straight pin header, 1x14, 2.54mm pitch, single row +Through hole pin header THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 2.54mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 2.54mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Horizontal +Through hole angled pin header, 1x15, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Vertical +Through hole straight pin header, 1x15, 2.54mm pitch, single row +Through hole pin header THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 2.54mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 2.54mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Horizontal +Through hole angled pin header, 1x16, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Vertical +Through hole straight pin header, 1x16, 2.54mm pitch, single row +Through hole pin header THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 2.54mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 2.54mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Horizontal +Through hole angled pin header, 1x17, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Vertical +Through hole straight pin header, 1x17, 2.54mm pitch, single row +Through hole pin header THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 2.54mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 2.54mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Horizontal +Through hole angled pin header, 1x18, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Vertical +Through hole straight pin header, 1x18, 2.54mm pitch, single row +Through hole pin header THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 2.54mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 2.54mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Horizontal +Through hole angled pin header, 1x19, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Vertical +Through hole straight pin header, 1x19, 2.54mm pitch, single row +Through hole pin header THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 2.54mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 2.54mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Horizontal +Through hole angled pin header, 1x20, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Vertical +Through hole straight pin header, 1x20, 2.54mm pitch, single row +Through hole pin header THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 2.54mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 2.54mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Horizontal +Through hole angled pin header, 1x21, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Vertical +Through hole straight pin header, 1x21, 2.54mm pitch, single row +Through hole pin header THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 2.54mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 2.54mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Horizontal +Through hole angled pin header, 1x22, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Vertical +Through hole straight pin header, 1x22, 2.54mm pitch, single row +Through hole pin header THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 2.54mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 2.54mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Horizontal +Through hole angled pin header, 1x23, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Vertical +Through hole straight pin header, 1x23, 2.54mm pitch, single row +Through hole pin header THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 2.54mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 2.54mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Horizontal +Through hole angled pin header, 1x24, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Vertical +Through hole straight pin header, 1x24, 2.54mm pitch, single row +Through hole pin header THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 2.54mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 2.54mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Horizontal +Through hole angled pin header, 1x25, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Vertical +Through hole straight pin header, 1x25, 2.54mm pitch, single row +Through hole pin header THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 2.54mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 2.54mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Horizontal +Through hole angled pin header, 1x26, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Vertical +Through hole straight pin header, 1x26, 2.54mm pitch, single row +Through hole pin header THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 2.54mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 2.54mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Horizontal +Through hole angled pin header, 1x27, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Vertical +Through hole straight pin header, 1x27, 2.54mm pitch, single row +Through hole pin header THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 2.54mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 2.54mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Horizontal +Through hole angled pin header, 1x28, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Vertical +Through hole straight pin header, 1x28, 2.54mm pitch, single row +Through hole pin header THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 2.54mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 2.54mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Horizontal +Through hole angled pin header, 1x29, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Vertical +Through hole straight pin header, 1x29, 2.54mm pitch, single row +Through hole pin header THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 2.54mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 2.54mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Horizontal +Through hole angled pin header, 1x30, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Vertical +Through hole straight pin header, 1x30, 2.54mm pitch, single row +Through hole pin header THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 2.54mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 2.54mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Horizontal +Through hole angled pin header, 1x31, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Vertical +Through hole straight pin header, 1x31, 2.54mm pitch, single row +Through hole pin header THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 2.54mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 2.54mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Horizontal +Through hole angled pin header, 1x32, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Vertical +Through hole straight pin header, 1x32, 2.54mm pitch, single row +Through hole pin header THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 2.54mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 2.54mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Horizontal +Through hole angled pin header, 1x33, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Vertical +Through hole straight pin header, 1x33, 2.54mm pitch, single row +Through hole pin header THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 2.54mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 2.54mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Horizontal +Through hole angled pin header, 1x34, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Vertical +Through hole straight pin header, 1x34, 2.54mm pitch, single row +Through hole pin header THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 2.54mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 2.54mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Horizontal +Through hole angled pin header, 1x35, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Vertical +Through hole straight pin header, 1x35, 2.54mm pitch, single row +Through hole pin header THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 2.54mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 2.54mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Horizontal +Through hole angled pin header, 1x36, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Vertical +Through hole straight pin header, 1x36, 2.54mm pitch, single row +Through hole pin header THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 2.54mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 2.54mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Horizontal +Through hole angled pin header, 1x37, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Vertical +Through hole straight pin header, 1x37, 2.54mm pitch, single row +Through hole pin header THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 2.54mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 2.54mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Horizontal +Through hole angled pin header, 1x38, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Vertical +Through hole straight pin header, 1x38, 2.54mm pitch, single row +Through hole pin header THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 2.54mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 2.54mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Horizontal +Through hole angled pin header, 1x39, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Vertical +Through hole straight pin header, 1x39, 2.54mm pitch, single row +Through hole pin header THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 2.54mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 2.54mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Horizontal +Through hole angled pin header, 1x40, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Vertical +Through hole straight pin header, 1x40, 2.54mm pitch, single row +Through hole pin header THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 2.54mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 2.54mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x01_P2.54mm_Horizontal +Through hole angled pin header, 2x01, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_2x01_P2.54mm_Vertical +Through hole straight pin header, 2x01, 2.54mm pitch, double rows +Through hole pin header THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_2x01_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x01 2.54mm double row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_2x02_P2.54mm_Horizontal +Through hole angled pin header, 2x02, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_2x02_P2.54mm_Vertical +Through hole straight pin header, 2x02, 2.54mm pitch, double rows +Through hole pin header THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_2x02_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x02 2.54mm double row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_2x03_P2.54mm_Horizontal +Through hole angled pin header, 2x03, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_2x03_P2.54mm_Vertical +Through hole straight pin header, 2x03, 2.54mm pitch, double rows +Through hole pin header THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_2x03_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x03 2.54mm double row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_2x04_P2.54mm_Horizontal +Through hole angled pin header, 2x04, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_2x04_P2.54mm_Vertical +Through hole straight pin header, 2x04, 2.54mm pitch, double rows +Through hole pin header THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_2x04_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x04 2.54mm double row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_2x05_P2.54mm_Horizontal +Through hole angled pin header, 2x05, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_2x05_P2.54mm_Vertical +Through hole straight pin header, 2x05, 2.54mm pitch, double rows +Through hole pin header THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_2x05_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x05 2.54mm double row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_2x06_P2.54mm_Horizontal +Through hole angled pin header, 2x06, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_2x06_P2.54mm_Vertical +Through hole straight pin header, 2x06, 2.54mm pitch, double rows +Through hole pin header THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_2x06_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x06 2.54mm double row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_2x07_P2.54mm_Horizontal +Through hole angled pin header, 2x07, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_2x07_P2.54mm_Vertical +Through hole straight pin header, 2x07, 2.54mm pitch, double rows +Through hole pin header THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_2x07_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x07 2.54mm double row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_2x08_P2.54mm_Horizontal +Through hole angled pin header, 2x08, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_2x08_P2.54mm_Vertical +Through hole straight pin header, 2x08, 2.54mm pitch, double rows +Through hole pin header THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_2x08_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x08 2.54mm double row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_2x09_P2.54mm_Horizontal +Through hole angled pin header, 2x09, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_2x09_P2.54mm_Vertical +Through hole straight pin header, 2x09, 2.54mm pitch, double rows +Through hole pin header THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_2x09_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x09 2.54mm double row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_2x10_P2.54mm_Horizontal +Through hole angled pin header, 2x10, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_2x10_P2.54mm_Vertical +Through hole straight pin header, 2x10, 2.54mm pitch, double rows +Through hole pin header THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_2x10_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x10 2.54mm double row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_2x11_P2.54mm_Horizontal +Through hole angled pin header, 2x11, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_2x11_P2.54mm_Vertical +Through hole straight pin header, 2x11, 2.54mm pitch, double rows +Through hole pin header THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_2x11_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x11 2.54mm double row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_2x12_P2.54mm_Horizontal +Through hole angled pin header, 2x12, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_2x12_P2.54mm_Vertical +Through hole straight pin header, 2x12, 2.54mm pitch, double rows +Through hole pin header THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_2x12_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x12 2.54mm double row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_2x13_P2.54mm_Horizontal +Through hole angled pin header, 2x13, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_2x13_P2.54mm_Vertical +Through hole straight pin header, 2x13, 2.54mm pitch, double rows +Through hole pin header THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_2x13_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x13 2.54mm double row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_2x14_P2.54mm_Horizontal +Through hole angled pin header, 2x14, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_2x14_P2.54mm_Vertical +Through hole straight pin header, 2x14, 2.54mm pitch, double rows +Through hole pin header THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_2x14_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x14 2.54mm double row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_2x15_P2.54mm_Horizontal +Through hole angled pin header, 2x15, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_2x15_P2.54mm_Vertical +Through hole straight pin header, 2x15, 2.54mm pitch, double rows +Through hole pin header THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_2x15_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x15 2.54mm double row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_2x16_P2.54mm_Horizontal +Through hole angled pin header, 2x16, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_2x16_P2.54mm_Vertical +Through hole straight pin header, 2x16, 2.54mm pitch, double rows +Through hole pin header THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_2x16_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x16 2.54mm double row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_2x17_P2.54mm_Horizontal +Through hole angled pin header, 2x17, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_2x17_P2.54mm_Vertical +Through hole straight pin header, 2x17, 2.54mm pitch, double rows +Through hole pin header THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_2x17_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x17 2.54mm double row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_2x18_P2.54mm_Horizontal +Through hole angled pin header, 2x18, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_2x18_P2.54mm_Vertical +Through hole straight pin header, 2x18, 2.54mm pitch, double rows +Through hole pin header THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_2x18_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x18 2.54mm double row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_2x19_P2.54mm_Horizontal +Through hole angled pin header, 2x19, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_2x19_P2.54mm_Vertical +Through hole straight pin header, 2x19, 2.54mm pitch, double rows +Through hole pin header THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_2x19_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x19 2.54mm double row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_2x20_P2.54mm_Horizontal +Through hole angled pin header, 2x20, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x20_P2.54mm_Vertical +Through hole straight pin header, 2x20, 2.54mm pitch, double rows +Through hole pin header THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x20_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x20 2.54mm double row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x21_P2.54mm_Horizontal +Through hole angled pin header, 2x21, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinHeader_2.54mm +PinHeader_2x21_P2.54mm_Vertical +Through hole straight pin header, 2x21, 2.54mm pitch, double rows +Through hole pin header THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinHeader_2.54mm +PinHeader_2x21_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x21 2.54mm double row +0 +42 +42 +Connector_PinHeader_2.54mm +PinHeader_2x22_P2.54mm_Horizontal +Through hole angled pin header, 2x22, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinHeader_2.54mm +PinHeader_2x22_P2.54mm_Vertical +Through hole straight pin header, 2x22, 2.54mm pitch, double rows +Through hole pin header THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinHeader_2.54mm +PinHeader_2x22_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x22 2.54mm double row +0 +44 +44 +Connector_PinHeader_2.54mm +PinHeader_2x23_P2.54mm_Horizontal +Through hole angled pin header, 2x23, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinHeader_2.54mm +PinHeader_2x23_P2.54mm_Vertical +Through hole straight pin header, 2x23, 2.54mm pitch, double rows +Through hole pin header THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinHeader_2.54mm +PinHeader_2x23_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x23 2.54mm double row +0 +46 +46 +Connector_PinHeader_2.54mm +PinHeader_2x24_P2.54mm_Horizontal +Through hole angled pin header, 2x24, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinHeader_2.54mm +PinHeader_2x24_P2.54mm_Vertical +Through hole straight pin header, 2x24, 2.54mm pitch, double rows +Through hole pin header THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinHeader_2.54mm +PinHeader_2x24_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x24 2.54mm double row +0 +48 +48 +Connector_PinHeader_2.54mm +PinHeader_2x25_P2.54mm_Horizontal +Through hole angled pin header, 2x25, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinHeader_2.54mm +PinHeader_2x25_P2.54mm_Vertical +Through hole straight pin header, 2x25, 2.54mm pitch, double rows +Through hole pin header THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinHeader_2.54mm +PinHeader_2x25_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x25 2.54mm double row +0 +50 +50 +Connector_PinHeader_2.54mm +PinHeader_2x26_P2.54mm_Horizontal +Through hole angled pin header, 2x26, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinHeader_2.54mm +PinHeader_2x26_P2.54mm_Vertical +Through hole straight pin header, 2x26, 2.54mm pitch, double rows +Through hole pin header THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinHeader_2.54mm +PinHeader_2x26_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x26 2.54mm double row +0 +52 +52 +Connector_PinHeader_2.54mm +PinHeader_2x27_P2.54mm_Horizontal +Through hole angled pin header, 2x27, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinHeader_2.54mm +PinHeader_2x27_P2.54mm_Vertical +Through hole straight pin header, 2x27, 2.54mm pitch, double rows +Through hole pin header THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinHeader_2.54mm +PinHeader_2x27_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x27 2.54mm double row +0 +54 +54 +Connector_PinHeader_2.54mm +PinHeader_2x28_P2.54mm_Horizontal +Through hole angled pin header, 2x28, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinHeader_2.54mm +PinHeader_2x28_P2.54mm_Vertical +Through hole straight pin header, 2x28, 2.54mm pitch, double rows +Through hole pin header THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinHeader_2.54mm +PinHeader_2x28_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x28 2.54mm double row +0 +56 +56 +Connector_PinHeader_2.54mm +PinHeader_2x29_P2.54mm_Horizontal +Through hole angled pin header, 2x29, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinHeader_2.54mm +PinHeader_2x29_P2.54mm_Vertical +Through hole straight pin header, 2x29, 2.54mm pitch, double rows +Through hole pin header THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinHeader_2.54mm +PinHeader_2x29_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x29 2.54mm double row +0 +58 +58 +Connector_PinHeader_2.54mm +PinHeader_2x30_P2.54mm_Horizontal +Through hole angled pin header, 2x30, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinHeader_2.54mm +PinHeader_2x30_P2.54mm_Vertical +Through hole straight pin header, 2x30, 2.54mm pitch, double rows +Through hole pin header THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinHeader_2.54mm +PinHeader_2x30_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x30 2.54mm double row +0 +60 +60 +Connector_PinHeader_2.54mm +PinHeader_2x31_P2.54mm_Horizontal +Through hole angled pin header, 2x31, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinHeader_2.54mm +PinHeader_2x31_P2.54mm_Vertical +Through hole straight pin header, 2x31, 2.54mm pitch, double rows +Through hole pin header THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinHeader_2.54mm +PinHeader_2x31_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x31 2.54mm double row +0 +62 +62 +Connector_PinHeader_2.54mm +PinHeader_2x32_P2.54mm_Horizontal +Through hole angled pin header, 2x32, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinHeader_2.54mm +PinHeader_2x32_P2.54mm_Vertical +Through hole straight pin header, 2x32, 2.54mm pitch, double rows +Through hole pin header THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinHeader_2.54mm +PinHeader_2x32_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x32 2.54mm double row +0 +64 +64 +Connector_PinHeader_2.54mm +PinHeader_2x33_P2.54mm_Horizontal +Through hole angled pin header, 2x33, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinHeader_2.54mm +PinHeader_2x33_P2.54mm_Vertical +Through hole straight pin header, 2x33, 2.54mm pitch, double rows +Through hole pin header THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinHeader_2.54mm +PinHeader_2x33_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x33 2.54mm double row +0 +66 +66 +Connector_PinHeader_2.54mm +PinHeader_2x34_P2.54mm_Horizontal +Through hole angled pin header, 2x34, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinHeader_2.54mm +PinHeader_2x34_P2.54mm_Vertical +Through hole straight pin header, 2x34, 2.54mm pitch, double rows +Through hole pin header THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinHeader_2.54mm +PinHeader_2x34_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x34 2.54mm double row +0 +68 +68 +Connector_PinHeader_2.54mm +PinHeader_2x35_P2.54mm_Horizontal +Through hole angled pin header, 2x35, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinHeader_2.54mm +PinHeader_2x35_P2.54mm_Vertical +Through hole straight pin header, 2x35, 2.54mm pitch, double rows +Through hole pin header THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinHeader_2.54mm +PinHeader_2x35_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x35 2.54mm double row +0 +70 +70 +Connector_PinHeader_2.54mm +PinHeader_2x36_P2.54mm_Horizontal +Through hole angled pin header, 2x36, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinHeader_2.54mm +PinHeader_2x36_P2.54mm_Vertical +Through hole straight pin header, 2x36, 2.54mm pitch, double rows +Through hole pin header THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinHeader_2.54mm +PinHeader_2x36_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x36 2.54mm double row +0 +72 +72 +Connector_PinHeader_2.54mm +PinHeader_2x37_P2.54mm_Horizontal +Through hole angled pin header, 2x37, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinHeader_2.54mm +PinHeader_2x37_P2.54mm_Vertical +Through hole straight pin header, 2x37, 2.54mm pitch, double rows +Through hole pin header THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinHeader_2.54mm +PinHeader_2x37_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x37 2.54mm double row +0 +74 +74 +Connector_PinHeader_2.54mm +PinHeader_2x38_P2.54mm_Horizontal +Through hole angled pin header, 2x38, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinHeader_2.54mm +PinHeader_2x38_P2.54mm_Vertical +Through hole straight pin header, 2x38, 2.54mm pitch, double rows +Through hole pin header THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinHeader_2.54mm +PinHeader_2x38_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x38 2.54mm double row +0 +76 +76 +Connector_PinHeader_2.54mm +PinHeader_2x39_P2.54mm_Horizontal +Through hole angled pin header, 2x39, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinHeader_2.54mm +PinHeader_2x39_P2.54mm_Vertical +Through hole straight pin header, 2x39, 2.54mm pitch, double rows +Through hole pin header THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinHeader_2.54mm +PinHeader_2x39_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x39 2.54mm double row +0 +78 +78 +Connector_PinHeader_2.54mm +PinHeader_2x40_P2.54mm_Horizontal +Through hole angled pin header, 2x40, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinHeader_2.54mm +PinHeader_2x40_P2.54mm_Vertical +Through hole straight pin header, 2x40, 2.54mm pitch, double rows +Through hole pin header THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinHeader_2.54mm +PinHeader_2x40_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x40 2.54mm double row +0 +80 +80 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical +Through hole straight socket strip, 1x02, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x02 1.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x02 1.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical +Through hole straight socket strip, 1x03, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x03 1.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x03 1.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical +Through hole straight socket strip, 1x04, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x04 1.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x04 1.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical +Through hole straight socket strip, 1x05, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x05 1.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x05 1.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical +Through hole straight socket strip, 1x06, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x06 1.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x06 1.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical +Through hole straight socket strip, 1x07, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x07 1.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x07 1.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical +Through hole straight socket strip, 1x08, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x08 1.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x08 1.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical +Through hole straight socket strip, 1x09, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x09 1.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x09 1.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical +Through hole straight socket strip, 1x10, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x10 1.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x10 1.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical +Through hole straight socket strip, 1x11, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x11 1.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x11 1.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical +Through hole straight socket strip, 1x12, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x12 1.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x12 1.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical +Through hole straight socket strip, 1x13, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x13 1.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x13 1.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical +Through hole straight socket strip, 1x14, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x14 1.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x14 1.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical +Through hole straight socket strip, 1x15, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x15 1.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x15 1.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical +Through hole straight socket strip, 1x16, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x16 1.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x16 1.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical +Through hole straight socket strip, 1x17, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x17 1.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x17 1.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical +Through hole straight socket strip, 1x18, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x18 1.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x18 1.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical +Through hole straight socket strip, 1x19, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x19 1.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x19 1.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical +Through hole straight socket strip, 1x20, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x20 1.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x20 1.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical +Through hole straight socket strip, 1x21, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x21 1.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x21 1.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical +Through hole straight socket strip, 1x22, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x22 1.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x22 1.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical +Through hole straight socket strip, 1x23, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x23 1.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x23 1.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical +Through hole straight socket strip, 1x24, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x24 1.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x24 1.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical +Through hole straight socket strip, 1x25, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x25 1.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x25 1.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical +Through hole straight socket strip, 1x26, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x26 1.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x26 1.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical +Through hole straight socket strip, 1x27, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x27 1.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x27 1.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical +Through hole straight socket strip, 1x28, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x28 1.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x28 1.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical +Through hole straight socket strip, 1x29, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x29 1.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x29 1.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical +Through hole straight socket strip, 1x30, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x30 1.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x30 1.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical +Through hole straight socket strip, 1x31, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x31 1.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x31 1.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical +Through hole straight socket strip, 1x32, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x32 1.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x32 1.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical +Through hole straight socket strip, 1x33, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x33 1.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x33 1.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical +Through hole straight socket strip, 1x34, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x34 1.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x34 1.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical +Through hole straight socket strip, 1x35, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x35 1.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x35 1.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical +Through hole straight socket strip, 1x36, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x36 1.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x36 1.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical +Through hole straight socket strip, 1x37, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x37 1.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x37 1.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical +Through hole straight socket strip, 1x38, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x38 1.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x38 1.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical +Through hole straight socket strip, 1x39, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x39 1.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x39 1.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical +Through hole straight socket strip, 1x40, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x40 1.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x40 1.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_2x02_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x02 1.00mm double row +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_2x03_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x03 1.00mm double row +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_2x04_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x04 1.00mm double row +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_2x05_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x05 1.00mm double row +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_2x06_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x06 1.00mm double row +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_2x07_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x07 1.00mm double row +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_2x08_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x08 1.00mm double row +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_2x09_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x09 1.00mm double row +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_2x10_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x10 1.00mm double row +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_2x11_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x11 1.00mm double row +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_2x12_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x12 1.00mm double row +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_2x13_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x13 1.00mm double row +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_2x14_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x14 1.00mm double row +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_2x15_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x15 1.00mm double row +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_2x16_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x16 1.00mm double row +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_2x17_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x17 1.00mm double row +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_2x18_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x18 1.00mm double row +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_2x19_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x19 1.00mm double row +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_2x20_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x20 1.00mm double row +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_2x21_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x21 1.00mm double row +0 +42 +42 +Connector_PinSocket_1.00mm +PinSocket_2x22_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x22 1.00mm double row +0 +44 +44 +Connector_PinSocket_1.00mm +PinSocket_2x23_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x23 1.00mm double row +0 +46 +46 +Connector_PinSocket_1.00mm +PinSocket_2x24_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x24 1.00mm double row +0 +48 +48 +Connector_PinSocket_1.00mm +PinSocket_2x25_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x25 1.00mm double row +0 +50 +50 +Connector_PinSocket_1.00mm +PinSocket_2x26_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x26 1.00mm double row +0 +52 +52 +Connector_PinSocket_1.00mm +PinSocket_2x27_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x27 1.00mm double row +0 +54 +54 +Connector_PinSocket_1.00mm +PinSocket_2x28_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x28 1.00mm double row +0 +56 +56 +Connector_PinSocket_1.00mm +PinSocket_2x29_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x29 1.00mm double row +0 +58 +58 +Connector_PinSocket_1.00mm +PinSocket_2x30_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x30 1.00mm double row +0 +60 +60 +Connector_PinSocket_1.00mm +PinSocket_2x31_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x31 1.00mm double row +0 +62 +62 +Connector_PinSocket_1.00mm +PinSocket_2x32_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x32 1.00mm double row +0 +64 +64 +Connector_PinSocket_1.00mm +PinSocket_2x33_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x33 1.00mm double row +0 +66 +66 +Connector_PinSocket_1.00mm +PinSocket_2x34_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x34 1.00mm double row +0 +68 +68 +Connector_PinSocket_1.00mm +PinSocket_2x35_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x35 1.00mm double row +0 +70 +70 +Connector_PinSocket_1.00mm +PinSocket_2x36_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x36 1.00mm double row +0 +72 +72 +Connector_PinSocket_1.00mm +PinSocket_2x37_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x37 1.00mm double row +0 +74 +74 +Connector_PinSocket_1.00mm +PinSocket_2x38_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x38 1.00mm double row +0 +76 +76 +Connector_PinSocket_1.00mm +PinSocket_2x39_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x39 1.00mm double row +0 +78 +78 +Connector_PinSocket_1.00mm +PinSocket_2x40_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x40 1.00mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_1x01_P1.27mm_Vertical +Through hole straight socket strip, 1x01, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x01 1.27mm single row +0 +1 +1 +Connector_PinSocket_1.27mm +PinSocket_1x02_P1.27mm_Vertical +Through hole straight socket strip, 1x02, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x02 1.27mm single row +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_1x02_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x02 1.27mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_1x02_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x02 1.27mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_1x03_P1.27mm_Vertical +Through hole straight socket strip, 1x03, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x03 1.27mm single row +0 +3 +3 +Connector_PinSocket_1.27mm +PinSocket_1x03_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x03 1.27mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_1.27mm +PinSocket_1x03_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x03 1.27mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_1.27mm +PinSocket_1x04_P1.27mm_Vertical +Through hole straight socket strip, 1x04, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x04 1.27mm single row +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_1x04_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x04 1.27mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_1x04_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x04 1.27mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_1x05_P1.27mm_Vertical +Through hole straight socket strip, 1x05, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x05 1.27mm single row +0 +5 +5 +Connector_PinSocket_1.27mm +PinSocket_1x05_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x05 1.27mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_1.27mm +PinSocket_1x05_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x05 1.27mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_1.27mm +PinSocket_1x06_P1.27mm_Vertical +Through hole straight socket strip, 1x06, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x06 1.27mm single row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_1x06_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x06 1.27mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_1x06_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x06 1.27mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_1x07_P1.27mm_Vertical +Through hole straight socket strip, 1x07, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x07 1.27mm single row +0 +7 +7 +Connector_PinSocket_1.27mm +PinSocket_1x07_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x07 1.27mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_1.27mm +PinSocket_1x07_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x07 1.27mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_1.27mm +PinSocket_1x08_P1.27mm_Vertical +Through hole straight socket strip, 1x08, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x08 1.27mm single row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_1x08_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x08 1.27mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_1x08_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x08 1.27mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_1x09_P1.27mm_Vertical +Through hole straight socket strip, 1x09, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x09 1.27mm single row +0 +9 +9 +Connector_PinSocket_1.27mm +PinSocket_1x09_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x09 1.27mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_1.27mm +PinSocket_1x09_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x09 1.27mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_1.27mm +PinSocket_1x10_P1.27mm_Vertical +Through hole straight socket strip, 1x10, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x10 1.27mm single row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_1x10_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x10 1.27mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_1x10_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x10 1.27mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_1x11_P1.27mm_Vertical +Through hole straight socket strip, 1x11, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x11 1.27mm single row +0 +11 +11 +Connector_PinSocket_1.27mm +PinSocket_1x11_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x11 1.27mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_1.27mm +PinSocket_1x11_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x11 1.27mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_1.27mm +PinSocket_1x12_P1.27mm_Vertical +Through hole straight socket strip, 1x12, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x12 1.27mm single row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_1x12_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x12 1.27mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_1x12_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x12 1.27mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_1x13_P1.27mm_Vertical +Through hole straight socket strip, 1x13, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x13 1.27mm single row +0 +13 +13 +Connector_PinSocket_1.27mm +PinSocket_1x13_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x13 1.27mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_1.27mm +PinSocket_1x13_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x13 1.27mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_1.27mm +PinSocket_1x14_P1.27mm_Vertical +Through hole straight socket strip, 1x14, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x14 1.27mm single row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_1x14_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x14 1.27mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_1x14_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x14 1.27mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_1x15_P1.27mm_Vertical +Through hole straight socket strip, 1x15, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x15 1.27mm single row +0 +15 +15 +Connector_PinSocket_1.27mm +PinSocket_1x15_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x15 1.27mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_1.27mm +PinSocket_1x15_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x15 1.27mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_1.27mm +PinSocket_1x16_P1.27mm_Vertical +Through hole straight socket strip, 1x16, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x16 1.27mm single row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_1x16_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x16 1.27mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_1x16_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x16 1.27mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_1x17_P1.27mm_Vertical +Through hole straight socket strip, 1x17, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x17 1.27mm single row +0 +17 +17 +Connector_PinSocket_1.27mm +PinSocket_1x17_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x17 1.27mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_1.27mm +PinSocket_1x17_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x17 1.27mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_1.27mm +PinSocket_1x18_P1.27mm_Vertical +Through hole straight socket strip, 1x18, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x18 1.27mm single row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_1x18_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x18 1.27mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_1x18_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x18 1.27mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_1x19_P1.27mm_Vertical +Through hole straight socket strip, 1x19, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x19 1.27mm single row +0 +19 +19 +Connector_PinSocket_1.27mm +PinSocket_1x19_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x19 1.27mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_1.27mm +PinSocket_1x19_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x19 1.27mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_1.27mm +PinSocket_1x20_P1.27mm_Vertical +Through hole straight socket strip, 1x20, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x20 1.27mm single row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_1x20_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x20 1.27mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_1x20_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x20 1.27mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_1x21_P1.27mm_Vertical +Through hole straight socket strip, 1x21, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x21 1.27mm single row +0 +21 +21 +Connector_PinSocket_1.27mm +PinSocket_1x21_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x21 1.27mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_1.27mm +PinSocket_1x21_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x21 1.27mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_1.27mm +PinSocket_1x22_P1.27mm_Vertical +Through hole straight socket strip, 1x22, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x22 1.27mm single row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_1x22_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x22 1.27mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_1x22_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x22 1.27mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_1x23_P1.27mm_Vertical +Through hole straight socket strip, 1x23, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x23 1.27mm single row +0 +23 +23 +Connector_PinSocket_1.27mm +PinSocket_1x23_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x23 1.27mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_1.27mm +PinSocket_1x23_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x23 1.27mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_1.27mm +PinSocket_1x24_P1.27mm_Vertical +Through hole straight socket strip, 1x24, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x24 1.27mm single row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_1x24_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x24 1.27mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_1x24_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x24 1.27mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_1x25_P1.27mm_Vertical +Through hole straight socket strip, 1x25, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x25 1.27mm single row +0 +25 +25 +Connector_PinSocket_1.27mm +PinSocket_1x25_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x25 1.27mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_1.27mm +PinSocket_1x25_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x25 1.27mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_1.27mm +PinSocket_1x26_P1.27mm_Vertical +Through hole straight socket strip, 1x26, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x26 1.27mm single row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_1x26_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x26 1.27mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_1x26_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x26 1.27mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_1x27_P1.27mm_Vertical +Through hole straight socket strip, 1x27, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x27 1.27mm single row +0 +27 +27 +Connector_PinSocket_1.27mm +PinSocket_1x27_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x27 1.27mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_1.27mm +PinSocket_1x27_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x27 1.27mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_1.27mm +PinSocket_1x28_P1.27mm_Vertical +Through hole straight socket strip, 1x28, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x28 1.27mm single row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_1x28_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x28 1.27mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_1x28_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x28 1.27mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_1x29_P1.27mm_Vertical +Through hole straight socket strip, 1x29, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x29 1.27mm single row +0 +29 +29 +Connector_PinSocket_1.27mm +PinSocket_1x29_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x29 1.27mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_1.27mm +PinSocket_1x29_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x29 1.27mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_1.27mm +PinSocket_1x30_P1.27mm_Vertical +Through hole straight socket strip, 1x30, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x30 1.27mm single row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_1x30_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x30 1.27mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_1x30_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x30 1.27mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_1x31_P1.27mm_Vertical +Through hole straight socket strip, 1x31, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x31 1.27mm single row +0 +31 +31 +Connector_PinSocket_1.27mm +PinSocket_1x31_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x31 1.27mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_1.27mm +PinSocket_1x31_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x31 1.27mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_1.27mm +PinSocket_1x32_P1.27mm_Vertical +Through hole straight socket strip, 1x32, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x32 1.27mm single row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_1x32_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x32 1.27mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_1x32_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x32 1.27mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_1x33_P1.27mm_Vertical +Through hole straight socket strip, 1x33, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x33 1.27mm single row +0 +33 +33 +Connector_PinSocket_1.27mm +PinSocket_1x33_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x33 1.27mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_1.27mm +PinSocket_1x33_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x33 1.27mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_1.27mm +PinSocket_1x34_P1.27mm_Vertical +Through hole straight socket strip, 1x34, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x34 1.27mm single row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_1x34_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x34 1.27mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_1x34_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x34 1.27mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_1x35_P1.27mm_Vertical +Through hole straight socket strip, 1x35, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x35 1.27mm single row +0 +35 +35 +Connector_PinSocket_1.27mm +PinSocket_1x35_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x35 1.27mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_1.27mm +PinSocket_1x35_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x35 1.27mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_1.27mm +PinSocket_1x36_P1.27mm_Vertical +Through hole straight socket strip, 1x36, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x36 1.27mm single row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_1x36_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x36 1.27mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_1x36_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x36 1.27mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_1x37_P1.27mm_Vertical +Through hole straight socket strip, 1x37, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x37 1.27mm single row +0 +37 +37 +Connector_PinSocket_1.27mm +PinSocket_1x37_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x37 1.27mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_1.27mm +PinSocket_1x37_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x37 1.27mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_1.27mm +PinSocket_1x38_P1.27mm_Vertical +Through hole straight socket strip, 1x38, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x38 1.27mm single row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_1x38_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x38 1.27mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_1x38_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x38 1.27mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_1x39_P1.27mm_Vertical +Through hole straight socket strip, 1x39, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x39 1.27mm single row +0 +39 +39 +Connector_PinSocket_1.27mm +PinSocket_1x39_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x39 1.27mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_1.27mm +PinSocket_1x39_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x39 1.27mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_1.27mm +PinSocket_1x40_P1.27mm_Vertical +Through hole straight socket strip, 1x40, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x40 1.27mm single row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_1x40_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x40 1.27mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_1x40_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x40 1.27mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x01_P1.27mm_Vertical +Through hole straight socket strip, 2x01, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x01 1.27mm double row +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_2x01_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x01, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x01 1.27mm double row +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_2x02_P1.27mm_Vertical +Through hole straight socket strip, 2x02, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x02 1.27mm double row +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_2x02_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x02 1.27mm double row +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_2x03_P1.27mm_Horizontal +Through hole angled socket strip, 2x03, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_2x03_P1.27mm_Vertical +Through hole straight socket strip, 2x03, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_2x03_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x03 1.27mm double row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_2x04_P1.27mm_Horizontal +Through hole angled socket strip, 2x04, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_2x04_P1.27mm_Vertical +Through hole straight socket strip, 2x04, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_2x04_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x04 1.27mm double row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_2x05_P1.27mm_Horizontal +Through hole angled socket strip, 2x05, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_2x05_P1.27mm_Vertical +Through hole straight socket strip, 2x05, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_2x05_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x05 1.27mm double row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_2x06_P1.27mm_Horizontal +Through hole angled socket strip, 2x06, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_2x06_P1.27mm_Vertical +Through hole straight socket strip, 2x06, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_2x06_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x06 1.27mm double row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_2x07_P1.27mm_Horizontal +Through hole angled socket strip, 2x07, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_2x07_P1.27mm_Vertical +Through hole straight socket strip, 2x07, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_2x07_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x07 1.27mm double row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_2x08_P1.27mm_Horizontal +Through hole angled socket strip, 2x08, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_2x08_P1.27mm_Vertical +Through hole straight socket strip, 2x08, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_2x08_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x08 1.27mm double row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_2x09_P1.27mm_Horizontal +Through hole angled socket strip, 2x09, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_2x09_P1.27mm_Vertical +Through hole straight socket strip, 2x09, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_2x09_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x09 1.27mm double row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_2x10_P1.27mm_Horizontal +Through hole angled socket strip, 2x10, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_2x10_P1.27mm_Vertical +Through hole straight socket strip, 2x10, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_2x10_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x10 1.27mm double row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_2x11_P1.27mm_Horizontal +Through hole angled socket strip, 2x11, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_2x11_P1.27mm_Vertical +Through hole straight socket strip, 2x11, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_2x11_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x11 1.27mm double row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_2x12_P1.27mm_Horizontal +Through hole angled socket strip, 2x12, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_2x12_P1.27mm_Vertical +Through hole straight socket strip, 2x12, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_2x12_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x12 1.27mm double row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_2x13_P1.27mm_Horizontal +Through hole angled socket strip, 2x13, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_2x13_P1.27mm_Vertical +Through hole straight socket strip, 2x13, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_2x13_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x13 1.27mm double row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_2x14_P1.27mm_Horizontal +Through hole angled socket strip, 2x14, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_2x14_P1.27mm_Vertical +Through hole straight socket strip, 2x14, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_2x14_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x14 1.27mm double row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_2x15_P1.27mm_Horizontal +Through hole angled socket strip, 2x15, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_2x15_P1.27mm_Vertical +Through hole straight socket strip, 2x15, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_2x15_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x15 1.27mm double row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_2x16_P1.27mm_Horizontal +Through hole angled socket strip, 2x16, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_2x16_P1.27mm_Vertical +Through hole straight socket strip, 2x16, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_2x16_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x16 1.27mm double row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_2x17_P1.27mm_Horizontal +Through hole angled socket strip, 2x17, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_2x17_P1.27mm_Vertical +Through hole straight socket strip, 2x17, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_2x17_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x17 1.27mm double row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_2x18_P1.27mm_Horizontal +Through hole angled socket strip, 2x18, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_2x18_P1.27mm_Vertical +Through hole straight socket strip, 2x18, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_2x18_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x18 1.27mm double row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_2x19_P1.27mm_Horizontal +Through hole angled socket strip, 2x19, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_2x19_P1.27mm_Vertical +Through hole straight socket strip, 2x19, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_2x19_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x19 1.27mm double row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_2x20_P1.27mm_Horizontal +Through hole angled socket strip, 2x20, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x20_P1.27mm_Vertical +Through hole straight socket strip, 2x20, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x20_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x20 1.27mm double row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x21_P1.27mm_Horizontal +Through hole angled socket strip, 2x21, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinSocket_1.27mm +PinSocket_2x21_P1.27mm_Vertical +Through hole straight socket strip, 2x21, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinSocket_1.27mm +PinSocket_2x21_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x21 1.27mm double row +0 +42 +42 +Connector_PinSocket_1.27mm +PinSocket_2x22_P1.27mm_Horizontal +Through hole angled socket strip, 2x22, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinSocket_1.27mm +PinSocket_2x22_P1.27mm_Vertical +Through hole straight socket strip, 2x22, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinSocket_1.27mm +PinSocket_2x22_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x22 1.27mm double row +0 +44 +44 +Connector_PinSocket_1.27mm +PinSocket_2x23_P1.27mm_Horizontal +Through hole angled socket strip, 2x23, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinSocket_1.27mm +PinSocket_2x23_P1.27mm_Vertical +Through hole straight socket strip, 2x23, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinSocket_1.27mm +PinSocket_2x23_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x23 1.27mm double row +0 +46 +46 +Connector_PinSocket_1.27mm +PinSocket_2x24_P1.27mm_Horizontal +Through hole angled socket strip, 2x24, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinSocket_1.27mm +PinSocket_2x24_P1.27mm_Vertical +Through hole straight socket strip, 2x24, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinSocket_1.27mm +PinSocket_2x24_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x24 1.27mm double row +0 +48 +48 +Connector_PinSocket_1.27mm +PinSocket_2x25_P1.27mm_Horizontal +Through hole angled socket strip, 2x25, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinSocket_1.27mm +PinSocket_2x25_P1.27mm_Vertical +Through hole straight socket strip, 2x25, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinSocket_1.27mm +PinSocket_2x25_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x25 1.27mm double row +0 +50 +50 +Connector_PinSocket_1.27mm +PinSocket_2x26_P1.27mm_Horizontal +Through hole angled socket strip, 2x26, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinSocket_1.27mm +PinSocket_2x26_P1.27mm_Vertical +Through hole straight socket strip, 2x26, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinSocket_1.27mm +PinSocket_2x26_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x26 1.27mm double row +0 +52 +52 +Connector_PinSocket_1.27mm +PinSocket_2x27_P1.27mm_Horizontal +Through hole angled socket strip, 2x27, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinSocket_1.27mm +PinSocket_2x27_P1.27mm_Vertical +Through hole straight socket strip, 2x27, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinSocket_1.27mm +PinSocket_2x27_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x27 1.27mm double row +0 +54 +54 +Connector_PinSocket_1.27mm +PinSocket_2x28_P1.27mm_Horizontal +Through hole angled socket strip, 2x28, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinSocket_1.27mm +PinSocket_2x28_P1.27mm_Vertical +Through hole straight socket strip, 2x28, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinSocket_1.27mm +PinSocket_2x28_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x28 1.27mm double row +0 +56 +56 +Connector_PinSocket_1.27mm +PinSocket_2x29_P1.27mm_Horizontal +Through hole angled socket strip, 2x29, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinSocket_1.27mm +PinSocket_2x29_P1.27mm_Vertical +Through hole straight socket strip, 2x29, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinSocket_1.27mm +PinSocket_2x29_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x29 1.27mm double row +0 +58 +58 +Connector_PinSocket_1.27mm +PinSocket_2x30_P1.27mm_Horizontal +Through hole angled socket strip, 2x30, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinSocket_1.27mm +PinSocket_2x30_P1.27mm_Vertical +Through hole straight socket strip, 2x30, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinSocket_1.27mm +PinSocket_2x30_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x30 1.27mm double row +0 +60 +60 +Connector_PinSocket_1.27mm +PinSocket_2x31_P1.27mm_Horizontal +Through hole angled socket strip, 2x31, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinSocket_1.27mm +PinSocket_2x31_P1.27mm_Vertical +Through hole straight socket strip, 2x31, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinSocket_1.27mm +PinSocket_2x31_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x31 1.27mm double row +0 +62 +62 +Connector_PinSocket_1.27mm +PinSocket_2x32_P1.27mm_Horizontal +Through hole angled socket strip, 2x32, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinSocket_1.27mm +PinSocket_2x32_P1.27mm_Vertical +Through hole straight socket strip, 2x32, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinSocket_1.27mm +PinSocket_2x32_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x32 1.27mm double row +0 +64 +64 +Connector_PinSocket_1.27mm +PinSocket_2x33_P1.27mm_Horizontal +Through hole angled socket strip, 2x33, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinSocket_1.27mm +PinSocket_2x33_P1.27mm_Vertical +Through hole straight socket strip, 2x33, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinSocket_1.27mm +PinSocket_2x33_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x33 1.27mm double row +0 +66 +66 +Connector_PinSocket_1.27mm +PinSocket_2x34_P1.27mm_Horizontal +Through hole angled socket strip, 2x34, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinSocket_1.27mm +PinSocket_2x34_P1.27mm_Vertical +Through hole straight socket strip, 2x34, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinSocket_1.27mm +PinSocket_2x34_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x34 1.27mm double row +0 +68 +68 +Connector_PinSocket_1.27mm +PinSocket_2x35_P1.27mm_Horizontal +Through hole angled socket strip, 2x35, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinSocket_1.27mm +PinSocket_2x35_P1.27mm_Vertical +Through hole straight socket strip, 2x35, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinSocket_1.27mm +PinSocket_2x35_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x35 1.27mm double row +0 +70 +70 +Connector_PinSocket_1.27mm +PinSocket_2x36_P1.27mm_Horizontal +Through hole angled socket strip, 2x36, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinSocket_1.27mm +PinSocket_2x36_P1.27mm_Vertical +Through hole straight socket strip, 2x36, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinSocket_1.27mm +PinSocket_2x36_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x36 1.27mm double row +0 +72 +72 +Connector_PinSocket_1.27mm +PinSocket_2x37_P1.27mm_Horizontal +Through hole angled socket strip, 2x37, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinSocket_1.27mm +PinSocket_2x37_P1.27mm_Vertical +Through hole straight socket strip, 2x37, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinSocket_1.27mm +PinSocket_2x37_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x37 1.27mm double row +0 +74 +74 +Connector_PinSocket_1.27mm +PinSocket_2x38_P1.27mm_Horizontal +Through hole angled socket strip, 2x38, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinSocket_1.27mm +PinSocket_2x38_P1.27mm_Vertical +Through hole straight socket strip, 2x38, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinSocket_1.27mm +PinSocket_2x38_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x38 1.27mm double row +0 +76 +76 +Connector_PinSocket_1.27mm +PinSocket_2x39_P1.27mm_Horizontal +Through hole angled socket strip, 2x39, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinSocket_1.27mm +PinSocket_2x39_P1.27mm_Vertical +Through hole straight socket strip, 2x39, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinSocket_1.27mm +PinSocket_2x39_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x39 1.27mm double row +0 +78 +78 +Connector_PinSocket_1.27mm +PinSocket_2x40_P1.27mm_Horizontal +Through hole angled socket strip, 2x40, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_2x40_P1.27mm_Vertical +Through hole straight socket strip, 2x40, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_2x40_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x40 1.27mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_2x41_P1.27mm_Horizontal +Through hole angled socket strip, 2x41, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x41 1.27mm double row +0 +82 +82 +Connector_PinSocket_1.27mm +PinSocket_2x42_P1.27mm_Horizontal +Through hole angled socket strip, 2x42, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x42 1.27mm double row +0 +84 +84 +Connector_PinSocket_1.27mm +PinSocket_2x43_P1.27mm_Horizontal +Through hole angled socket strip, 2x43, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x43 1.27mm double row +0 +86 +86 +Connector_PinSocket_1.27mm +PinSocket_2x44_P1.27mm_Horizontal +Through hole angled socket strip, 2x44, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x44 1.27mm double row +0 +88 +88 +Connector_PinSocket_1.27mm +PinSocket_2x45_P1.27mm_Horizontal +Through hole angled socket strip, 2x45, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x45 1.27mm double row +0 +90 +90 +Connector_PinSocket_1.27mm +PinSocket_2x46_P1.27mm_Horizontal +Through hole angled socket strip, 2x46, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x46 1.27mm double row +0 +92 +92 +Connector_PinSocket_1.27mm +PinSocket_2x47_P1.27mm_Horizontal +Through hole angled socket strip, 2x47, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x47 1.27mm double row +0 +94 +94 +Connector_PinSocket_1.27mm +PinSocket_2x48_P1.27mm_Horizontal +Through hole angled socket strip, 2x48, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x48 1.27mm double row +0 +96 +96 +Connector_PinSocket_1.27mm +PinSocket_2x49_P1.27mm_Horizontal +Through hole angled socket strip, 2x49, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x49 1.27mm double row +0 +98 +98 +Connector_PinSocket_1.27mm +PinSocket_2x50_P1.27mm_Horizontal +Through hole angled socket strip, 2x50, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x50 1.27mm double row +0 +100 +100 +Connector_PinSocket_2.00mm +PinSocket_1x01_P2.00mm_Horizontal +Through hole angled socket strip, 1x01, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinSocket_2.00mm +PinSocket_1x01_P2.00mm_Vertical +Through hole straight socket strip, 1x01, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Horizontal +Through hole angled socket strip, 1x02, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Vertical +Through hole straight socket strip, 1x02, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x02 2.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x02 2.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Horizontal +Through hole angled socket strip, 1x03, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Vertical +Through hole straight socket strip, 1x03, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x03 2.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x03 2.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Horizontal +Through hole angled socket strip, 1x04, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Vertical +Through hole straight socket strip, 1x04, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x04 2.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x04 2.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Horizontal +Through hole angled socket strip, 1x05, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Vertical +Through hole straight socket strip, 1x05, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x05 2.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x05 2.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Horizontal +Through hole angled socket strip, 1x06, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Vertical +Through hole straight socket strip, 1x06, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x06 2.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x06 2.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Horizontal +Through hole angled socket strip, 1x07, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Vertical +Through hole straight socket strip, 1x07, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x07 2.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x07 2.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Horizontal +Through hole angled socket strip, 1x08, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Vertical +Through hole straight socket strip, 1x08, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x08 2.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x08 2.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Horizontal +Through hole angled socket strip, 1x09, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Vertical +Through hole straight socket strip, 1x09, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x09 2.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x09 2.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Horizontal +Through hole angled socket strip, 1x10, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Vertical +Through hole straight socket strip, 1x10, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x10 2.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x10 2.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Horizontal +Through hole angled socket strip, 1x11, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Vertical +Through hole straight socket strip, 1x11, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x11 2.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x11 2.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Horizontal +Through hole angled socket strip, 1x12, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Vertical +Through hole straight socket strip, 1x12, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x12 2.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x12 2.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Horizontal +Through hole angled socket strip, 1x13, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Vertical +Through hole straight socket strip, 1x13, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x13 2.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x13 2.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Horizontal +Through hole angled socket strip, 1x14, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Vertical +Through hole straight socket strip, 1x14, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x14 2.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x14 2.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Horizontal +Through hole angled socket strip, 1x15, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Vertical +Through hole straight socket strip, 1x15, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x15 2.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x15 2.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Horizontal +Through hole angled socket strip, 1x16, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Vertical +Through hole straight socket strip, 1x16, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x16 2.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x16 2.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Horizontal +Through hole angled socket strip, 1x17, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Vertical +Through hole straight socket strip, 1x17, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x17 2.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x17 2.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Horizontal +Through hole angled socket strip, 1x18, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Vertical +Through hole straight socket strip, 1x18, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x18 2.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x18 2.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Horizontal +Through hole angled socket strip, 1x19, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Vertical +Through hole straight socket strip, 1x19, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x19 2.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x19 2.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Horizontal +Through hole angled socket strip, 1x20, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Vertical +Through hole straight socket strip, 1x20, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x20 2.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x20 2.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Horizontal +Through hole angled socket strip, 1x21, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Vertical +Through hole straight socket strip, 1x21, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x21 2.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x21 2.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Horizontal +Through hole angled socket strip, 1x22, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Vertical +Through hole straight socket strip, 1x22, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x22 2.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x22 2.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Horizontal +Through hole angled socket strip, 1x23, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Vertical +Through hole straight socket strip, 1x23, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x23 2.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x23 2.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Horizontal +Through hole angled socket strip, 1x24, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Vertical +Through hole straight socket strip, 1x24, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x24 2.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x24 2.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Horizontal +Through hole angled socket strip, 1x25, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Vertical +Through hole straight socket strip, 1x25, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x25 2.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x25 2.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Horizontal +Through hole angled socket strip, 1x26, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Vertical +Through hole straight socket strip, 1x26, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x26 2.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x26 2.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Horizontal +Through hole angled socket strip, 1x27, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Vertical +Through hole straight socket strip, 1x27, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x27 2.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x27 2.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Horizontal +Through hole angled socket strip, 1x28, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Vertical +Through hole straight socket strip, 1x28, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x28 2.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x28 2.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Horizontal +Through hole angled socket strip, 1x29, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Vertical +Through hole straight socket strip, 1x29, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x29 2.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x29 2.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Horizontal +Through hole angled socket strip, 1x30, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Vertical +Through hole straight socket strip, 1x30, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x30 2.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x30 2.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Horizontal +Through hole angled socket strip, 1x31, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Vertical +Through hole straight socket strip, 1x31, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x31 2.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x31 2.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Horizontal +Through hole angled socket strip, 1x32, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Vertical +Through hole straight socket strip, 1x32, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x32 2.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x32 2.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Horizontal +Through hole angled socket strip, 1x33, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Vertical +Through hole straight socket strip, 1x33, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x33 2.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x33 2.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Horizontal +Through hole angled socket strip, 1x34, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Vertical +Through hole straight socket strip, 1x34, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x34 2.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x34 2.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Horizontal +Through hole angled socket strip, 1x35, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Vertical +Through hole straight socket strip, 1x35, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x35 2.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x35 2.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Horizontal +Through hole angled socket strip, 1x36, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Vertical +Through hole straight socket strip, 1x36, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x36 2.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x36 2.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Horizontal +Through hole angled socket strip, 1x37, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Vertical +Through hole straight socket strip, 1x37, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x37 2.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x37 2.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Horizontal +Through hole angled socket strip, 1x38, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Vertical +Through hole straight socket strip, 1x38, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x38 2.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x38 2.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Horizontal +Through hole angled socket strip, 1x39, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Vertical +Through hole straight socket strip, 1x39, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x39 2.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x39 2.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Horizontal +Through hole angled socket strip, 1x40, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Vertical +Through hole straight socket strip, 1x40, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x40 2.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x40 2.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x01_P2.00mm_Horizontal +Through hole angled socket strip, 2x01, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_2x01_P2.00mm_Vertical +Through hole straight socket strip, 2x01, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_2x01_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x01, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x01 2.00mm double row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_2x02_P2.00mm_Horizontal +Through hole angled socket strip, 2x02, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_2x02_P2.00mm_Vertical +Through hole straight socket strip, 2x02, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_2x02_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x02 2.00mm double row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_2x03_P2.00mm_Horizontal +Through hole angled socket strip, 2x03, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_2x03_P2.00mm_Vertical +Through hole straight socket strip, 2x03, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_2x03_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x03 2.00mm double row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_2x04_P2.00mm_Horizontal +Through hole angled socket strip, 2x04, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_2x04_P2.00mm_Vertical +Through hole straight socket strip, 2x04, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_2x04_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x04 2.00mm double row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_2x05_P2.00mm_Horizontal +Through hole angled socket strip, 2x05, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_2x05_P2.00mm_Vertical +Through hole straight socket strip, 2x05, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_2x05_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x05 2.00mm double row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_2x06_P2.00mm_Horizontal +Through hole angled socket strip, 2x06, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_2x06_P2.00mm_Vertical +Through hole straight socket strip, 2x06, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_2x06_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x06 2.00mm double row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_2x07_P2.00mm_Horizontal +Through hole angled socket strip, 2x07, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_2x07_P2.00mm_Vertical +Through hole straight socket strip, 2x07, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_2x07_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x07 2.00mm double row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_2x08_P2.00mm_Horizontal +Through hole angled socket strip, 2x08, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_2x08_P2.00mm_Vertical +Through hole straight socket strip, 2x08, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_2x08_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x08 2.00mm double row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_2x09_P2.00mm_Horizontal +Through hole angled socket strip, 2x09, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_2x09_P2.00mm_Vertical +Through hole straight socket strip, 2x09, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_2x09_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x09 2.00mm double row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_2x10_P2.00mm_Horizontal +Through hole angled socket strip, 2x10, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_2x10_P2.00mm_Vertical +Through hole straight socket strip, 2x10, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_2x10_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x10 2.00mm double row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_2x11_P2.00mm_Horizontal +Through hole angled socket strip, 2x11, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_2x11_P2.00mm_Vertical +Through hole straight socket strip, 2x11, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_2x11_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x11 2.00mm double row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_2x12_P2.00mm_Horizontal +Through hole angled socket strip, 2x12, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_2x12_P2.00mm_Vertical +Through hole straight socket strip, 2x12, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_2x12_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x12 2.00mm double row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_2x13_P2.00mm_Horizontal +Through hole angled socket strip, 2x13, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_2x13_P2.00mm_Vertical +Through hole straight socket strip, 2x13, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_2x13_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x13 2.00mm double row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_2x14_P2.00mm_Horizontal +Through hole angled socket strip, 2x14, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_2x14_P2.00mm_Vertical +Through hole straight socket strip, 2x14, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_2x14_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x14 2.00mm double row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_2x15_P2.00mm_Horizontal +Through hole angled socket strip, 2x15, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_2x15_P2.00mm_Vertical +Through hole straight socket strip, 2x15, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_2x15_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x15 2.00mm double row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_2x16_P2.00mm_Horizontal +Through hole angled socket strip, 2x16, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_2x16_P2.00mm_Vertical +Through hole straight socket strip, 2x16, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_2x16_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x16 2.00mm double row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_2x17_P2.00mm_Horizontal +Through hole angled socket strip, 2x17, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_2x17_P2.00mm_Vertical +Through hole straight socket strip, 2x17, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_2x17_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x17 2.00mm double row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_2x18_P2.00mm_Horizontal +Through hole angled socket strip, 2x18, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_2x18_P2.00mm_Vertical +Through hole straight socket strip, 2x18, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_2x18_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x18 2.00mm double row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_2x19_P2.00mm_Horizontal +Through hole angled socket strip, 2x19, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_2x19_P2.00mm_Vertical +Through hole straight socket strip, 2x19, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_2x19_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x19 2.00mm double row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_2x20_P2.00mm_Horizontal +Through hole angled socket strip, 2x20, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x20_P2.00mm_Vertical +Through hole straight socket strip, 2x20, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x20_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x20 2.00mm double row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x21_P2.00mm_Horizontal +Through hole angled socket strip, 2x21, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinSocket_2.00mm +PinSocket_2x21_P2.00mm_Vertical +Through hole straight socket strip, 2x21, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinSocket_2.00mm +PinSocket_2x21_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x21 2.00mm double row +0 +42 +42 +Connector_PinSocket_2.00mm +PinSocket_2x22_P2.00mm_Horizontal +Through hole angled socket strip, 2x22, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinSocket_2.00mm +PinSocket_2x22_P2.00mm_Vertical +Through hole straight socket strip, 2x22, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinSocket_2.00mm +PinSocket_2x22_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x22 2.00mm double row +0 +44 +44 +Connector_PinSocket_2.00mm +PinSocket_2x23_P2.00mm_Horizontal +Through hole angled socket strip, 2x23, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinSocket_2.00mm +PinSocket_2x23_P2.00mm_Vertical +Through hole straight socket strip, 2x23, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinSocket_2.00mm +PinSocket_2x23_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x23 2.00mm double row +0 +46 +46 +Connector_PinSocket_2.00mm +PinSocket_2x24_P2.00mm_Horizontal +Through hole angled socket strip, 2x24, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinSocket_2.00mm +PinSocket_2x24_P2.00mm_Vertical +Through hole straight socket strip, 2x24, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinSocket_2.00mm +PinSocket_2x24_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x24 2.00mm double row +0 +48 +48 +Connector_PinSocket_2.00mm +PinSocket_2x25_P2.00mm_Horizontal +Through hole angled socket strip, 2x25, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinSocket_2.00mm +PinSocket_2x25_P2.00mm_Vertical +Through hole straight socket strip, 2x25, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinSocket_2.00mm +PinSocket_2x25_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x25 2.00mm double row +0 +50 +50 +Connector_PinSocket_2.00mm +PinSocket_2x26_P2.00mm_Horizontal +Through hole angled socket strip, 2x26, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinSocket_2.00mm +PinSocket_2x26_P2.00mm_Vertical +Through hole straight socket strip, 2x26, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinSocket_2.00mm +PinSocket_2x26_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x26 2.00mm double row +0 +52 +52 +Connector_PinSocket_2.00mm +PinSocket_2x27_P2.00mm_Horizontal +Through hole angled socket strip, 2x27, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinSocket_2.00mm +PinSocket_2x27_P2.00mm_Vertical +Through hole straight socket strip, 2x27, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinSocket_2.00mm +PinSocket_2x27_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x27 2.00mm double row +0 +54 +54 +Connector_PinSocket_2.00mm +PinSocket_2x28_P2.00mm_Horizontal +Through hole angled socket strip, 2x28, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinSocket_2.00mm +PinSocket_2x28_P2.00mm_Vertical +Through hole straight socket strip, 2x28, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinSocket_2.00mm +PinSocket_2x28_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x28 2.00mm double row +0 +56 +56 +Connector_PinSocket_2.00mm +PinSocket_2x29_P2.00mm_Horizontal +Through hole angled socket strip, 2x29, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinSocket_2.00mm +PinSocket_2x29_P2.00mm_Vertical +Through hole straight socket strip, 2x29, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinSocket_2.00mm +PinSocket_2x29_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x29 2.00mm double row +0 +58 +58 +Connector_PinSocket_2.00mm +PinSocket_2x30_P2.00mm_Horizontal +Through hole angled socket strip, 2x30, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinSocket_2.00mm +PinSocket_2x30_P2.00mm_Vertical +Through hole straight socket strip, 2x30, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinSocket_2.00mm +PinSocket_2x30_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x30 2.00mm double row +0 +60 +60 +Connector_PinSocket_2.00mm +PinSocket_2x31_P2.00mm_Horizontal +Through hole angled socket strip, 2x31, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinSocket_2.00mm +PinSocket_2x31_P2.00mm_Vertical +Through hole straight socket strip, 2x31, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinSocket_2.00mm +PinSocket_2x31_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x31 2.00mm double row +0 +62 +62 +Connector_PinSocket_2.00mm +PinSocket_2x32_P2.00mm_Horizontal +Through hole angled socket strip, 2x32, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinSocket_2.00mm +PinSocket_2x32_P2.00mm_Vertical +Through hole straight socket strip, 2x32, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinSocket_2.00mm +PinSocket_2x32_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x32 2.00mm double row +0 +64 +64 +Connector_PinSocket_2.00mm +PinSocket_2x33_P2.00mm_Horizontal +Through hole angled socket strip, 2x33, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinSocket_2.00mm +PinSocket_2x33_P2.00mm_Vertical +Through hole straight socket strip, 2x33, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinSocket_2.00mm +PinSocket_2x33_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x33 2.00mm double row +0 +66 +66 +Connector_PinSocket_2.00mm +PinSocket_2x34_P2.00mm_Horizontal +Through hole angled socket strip, 2x34, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinSocket_2.00mm +PinSocket_2x34_P2.00mm_Vertical +Through hole straight socket strip, 2x34, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinSocket_2.00mm +PinSocket_2x34_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x34 2.00mm double row +0 +68 +68 +Connector_PinSocket_2.00mm +PinSocket_2x35_P2.00mm_Horizontal +Through hole angled socket strip, 2x35, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinSocket_2.00mm +PinSocket_2x35_P2.00mm_Vertical +Through hole straight socket strip, 2x35, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinSocket_2.00mm +PinSocket_2x35_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x35 2.00mm double row +0 +70 +70 +Connector_PinSocket_2.00mm +PinSocket_2x36_P2.00mm_Horizontal +Through hole angled socket strip, 2x36, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinSocket_2.00mm +PinSocket_2x36_P2.00mm_Vertical +Through hole straight socket strip, 2x36, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinSocket_2.00mm +PinSocket_2x36_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x36 2.00mm double row +0 +72 +72 +Connector_PinSocket_2.00mm +PinSocket_2x37_P2.00mm_Horizontal +Through hole angled socket strip, 2x37, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinSocket_2.00mm +PinSocket_2x37_P2.00mm_Vertical +Through hole straight socket strip, 2x37, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinSocket_2.00mm +PinSocket_2x37_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x37 2.00mm double row +0 +74 +74 +Connector_PinSocket_2.00mm +PinSocket_2x38_P2.00mm_Horizontal +Through hole angled socket strip, 2x38, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinSocket_2.00mm +PinSocket_2x38_P2.00mm_Vertical +Through hole straight socket strip, 2x38, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinSocket_2.00mm +PinSocket_2x38_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x38 2.00mm double row +0 +76 +76 +Connector_PinSocket_2.00mm +PinSocket_2x39_P2.00mm_Horizontal +Through hole angled socket strip, 2x39, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinSocket_2.00mm +PinSocket_2x39_P2.00mm_Vertical +Through hole straight socket strip, 2x39, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinSocket_2.00mm +PinSocket_2x39_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x39 2.00mm double row +0 +78 +78 +Connector_PinSocket_2.00mm +PinSocket_2x40_P2.00mm_Horizontal +Through hole angled socket strip, 2x40, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinSocket_2.00mm +PinSocket_2x40_P2.00mm_Vertical +Through hole straight socket strip, 2x40, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinSocket_2.00mm +PinSocket_2x40_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x40 2.00mm double row +0 +80 +80 +Connector_PinSocket_2.54mm +PinSocket_1x01_P2.54mm_Horizontal +Through hole angled socket strip, 1x01, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinSocket_2.54mm +PinSocket_1x01_P2.54mm_Vertical +Through hole straight socket strip, 1x01, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Horizontal +Through hole angled socket strip, 1x02, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Vertical +Through hole straight socket strip, 1x02, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x02 2.54mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x02 2.54mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Horizontal +Through hole angled socket strip, 1x03, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Vertical +Through hole straight socket strip, 1x03, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x03 2.54mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x03 2.54mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Horizontal +Through hole angled socket strip, 1x04, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Vertical +Through hole straight socket strip, 1x04, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x04 2.54mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x04 2.54mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Horizontal +Through hole angled socket strip, 1x05, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Vertical +Through hole straight socket strip, 1x05, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x05 2.54mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x05 2.54mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Horizontal +Through hole angled socket strip, 1x06, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Vertical +Through hole straight socket strip, 1x06, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x06 2.54mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x06 2.54mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Horizontal +Through hole angled socket strip, 1x07, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Vertical +Through hole straight socket strip, 1x07, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x07 2.54mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x07 2.54mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Horizontal +Through hole angled socket strip, 1x08, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Vertical +Through hole straight socket strip, 1x08, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x08 2.54mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x08 2.54mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Horizontal +Through hole angled socket strip, 1x09, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Vertical +Through hole straight socket strip, 1x09, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x09 2.54mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x09 2.54mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Horizontal +Through hole angled socket strip, 1x10, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Vertical +Through hole straight socket strip, 1x10, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x10 2.54mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x10 2.54mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Horizontal +Through hole angled socket strip, 1x11, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Vertical +Through hole straight socket strip, 1x11, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x11 2.54mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x11 2.54mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Horizontal +Through hole angled socket strip, 1x12, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Vertical +Through hole straight socket strip, 1x12, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x12 2.54mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x12 2.54mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Horizontal +Through hole angled socket strip, 1x13, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Vertical +Through hole straight socket strip, 1x13, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x13 2.54mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x13 2.54mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Horizontal +Through hole angled socket strip, 1x14, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Vertical +Through hole straight socket strip, 1x14, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x14 2.54mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x14 2.54mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Horizontal +Through hole angled socket strip, 1x15, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Vertical +Through hole straight socket strip, 1x15, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x15 2.54mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x15 2.54mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Horizontal +Through hole angled socket strip, 1x16, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Vertical +Through hole straight socket strip, 1x16, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x16 2.54mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x16 2.54mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Horizontal +Through hole angled socket strip, 1x17, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Vertical +Through hole straight socket strip, 1x17, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x17 2.54mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x17 2.54mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Horizontal +Through hole angled socket strip, 1x18, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Vertical +Through hole straight socket strip, 1x18, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x18 2.54mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x18 2.54mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Horizontal +Through hole angled socket strip, 1x19, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Vertical +Through hole straight socket strip, 1x19, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x19 2.54mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x19 2.54mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Horizontal +Through hole angled socket strip, 1x20, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Vertical +Through hole straight socket strip, 1x20, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x20 2.54mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x20 2.54mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Horizontal +Through hole angled socket strip, 1x21, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Vertical +Through hole straight socket strip, 1x21, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x21 2.54mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x21 2.54mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Horizontal +Through hole angled socket strip, 1x22, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Vertical +Through hole straight socket strip, 1x22, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x22 2.54mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x22 2.54mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Horizontal +Through hole angled socket strip, 1x23, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Vertical +Through hole straight socket strip, 1x23, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x23 2.54mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x23 2.54mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Horizontal +Through hole angled socket strip, 1x24, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Vertical +Through hole straight socket strip, 1x24, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x24 2.54mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x24 2.54mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Horizontal +Through hole angled socket strip, 1x25, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Vertical +Through hole straight socket strip, 1x25, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x25 2.54mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x25 2.54mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Horizontal +Through hole angled socket strip, 1x26, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Vertical +Through hole straight socket strip, 1x26, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x26 2.54mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x26 2.54mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Horizontal +Through hole angled socket strip, 1x27, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Vertical +Through hole straight socket strip, 1x27, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x27 2.54mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x27 2.54mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Horizontal +Through hole angled socket strip, 1x28, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Vertical +Through hole straight socket strip, 1x28, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x28 2.54mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x28 2.54mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Horizontal +Through hole angled socket strip, 1x29, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Vertical +Through hole straight socket strip, 1x29, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x29 2.54mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x29 2.54mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Horizontal +Through hole angled socket strip, 1x30, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Vertical +Through hole straight socket strip, 1x30, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x30 2.54mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x30 2.54mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Horizontal +Through hole angled socket strip, 1x31, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Vertical +Through hole straight socket strip, 1x31, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x31 2.54mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x31 2.54mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Horizontal +Through hole angled socket strip, 1x32, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Vertical +Through hole straight socket strip, 1x32, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x32 2.54mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x32 2.54mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Horizontal +Through hole angled socket strip, 1x33, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Vertical +Through hole straight socket strip, 1x33, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x33 2.54mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x33 2.54mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Horizontal +Through hole angled socket strip, 1x34, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Vertical +Through hole straight socket strip, 1x34, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x34 2.54mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x34 2.54mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Horizontal +Through hole angled socket strip, 1x35, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Vertical +Through hole straight socket strip, 1x35, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x35 2.54mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x35 2.54mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Horizontal +Through hole angled socket strip, 1x36, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Vertical +Through hole straight socket strip, 1x36, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x36 2.54mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x36 2.54mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Horizontal +Through hole angled socket strip, 1x37, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Vertical +Through hole straight socket strip, 1x37, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x37 2.54mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x37 2.54mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Horizontal +Through hole angled socket strip, 1x38, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Vertical +Through hole straight socket strip, 1x38, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x38 2.54mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x38 2.54mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Horizontal +Through hole angled socket strip, 1x39, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Vertical +Through hole straight socket strip, 1x39, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x39 2.54mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x39 2.54mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Horizontal +Through hole angled socket strip, 1x40, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Vertical +Through hole straight socket strip, 1x40, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x40 2.54mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x40 2.54mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x01_P2.54mm_Horizontal +Through hole angled socket strip, 2x01, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_2x01_P2.54mm_Vertical +Through hole straight socket strip, 2x01, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_2x01_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x01, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x01 2.54mm double row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_2x02_P2.54mm_Horizontal +Through hole angled socket strip, 2x02, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_2x02_P2.54mm_Vertical +Through hole straight socket strip, 2x02, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_2x02_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x02 2.54mm double row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_2x03_P2.54mm_Horizontal +Through hole angled socket strip, 2x03, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_2x03_P2.54mm_Vertical +Through hole straight socket strip, 2x03, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_2x03_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x03 2.54mm double row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_2x04_P2.54mm_Horizontal +Through hole angled socket strip, 2x04, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_2x04_P2.54mm_Vertical +Through hole straight socket strip, 2x04, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_2x04_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x04 2.54mm double row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_2x05_P2.54mm_Horizontal +Through hole angled socket strip, 2x05, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_2x05_P2.54mm_Vertical +Through hole straight socket strip, 2x05, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_2x05_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x05 2.54mm double row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_2x06_P2.54mm_Horizontal +Through hole angled socket strip, 2x06, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_2x06_P2.54mm_Vertical +Through hole straight socket strip, 2x06, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_2x06_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x06 2.54mm double row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_2x07_P2.54mm_Horizontal +Through hole angled socket strip, 2x07, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_2x07_P2.54mm_Vertical +Through hole straight socket strip, 2x07, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_2x07_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x07 2.54mm double row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_2x08_P2.54mm_Horizontal +Through hole angled socket strip, 2x08, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_2x08_P2.54mm_Vertical +Through hole straight socket strip, 2x08, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_2x08_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x08 2.54mm double row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_2x09_P2.54mm_Horizontal +Through hole angled socket strip, 2x09, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_2x09_P2.54mm_Vertical +Through hole straight socket strip, 2x09, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_2x09_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x09 2.54mm double row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_2x10_P2.54mm_Horizontal +Through hole angled socket strip, 2x10, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_2x10_P2.54mm_Vertical +Through hole straight socket strip, 2x10, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_2x10_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x10 2.54mm double row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_2x11_P2.54mm_Horizontal +Through hole angled socket strip, 2x11, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_2x11_P2.54mm_Vertical +Through hole straight socket strip, 2x11, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_2x11_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x11 2.54mm double row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_2x12_P2.54mm_Horizontal +Through hole angled socket strip, 2x12, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_2x12_P2.54mm_Vertical +Through hole straight socket strip, 2x12, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_2x12_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x12 2.54mm double row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_2x13_P2.54mm_Horizontal +Through hole angled socket strip, 2x13, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_2x13_P2.54mm_Vertical +Through hole straight socket strip, 2x13, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_2x13_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x13 2.54mm double row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_2x14_P2.54mm_Horizontal +Through hole angled socket strip, 2x14, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_2x14_P2.54mm_Vertical +Through hole straight socket strip, 2x14, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_2x14_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x14 2.54mm double row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_2x15_P2.54mm_Horizontal +Through hole angled socket strip, 2x15, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_2x15_P2.54mm_Vertical +Through hole straight socket strip, 2x15, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_2x15_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x15 2.54mm double row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_2x16_P2.54mm_Horizontal +Through hole angled socket strip, 2x16, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_2x16_P2.54mm_Vertical +Through hole straight socket strip, 2x16, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_2x16_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x16 2.54mm double row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_2x17_P2.54mm_Horizontal +Through hole angled socket strip, 2x17, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_2x17_P2.54mm_Vertical +Through hole straight socket strip, 2x17, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_2x17_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x17 2.54mm double row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_2x18_P2.54mm_Horizontal +Through hole angled socket strip, 2x18, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_2x18_P2.54mm_Vertical +Through hole straight socket strip, 2x18, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_2x18_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x18 2.54mm double row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_2x19_P2.54mm_Horizontal +Through hole angled socket strip, 2x19, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_2x19_P2.54mm_Vertical +Through hole straight socket strip, 2x19, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_2x19_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x19 2.54mm double row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_2x20_P2.54mm_Horizontal +Through hole angled socket strip, 2x20, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x20_P2.54mm_Vertical +Through hole straight socket strip, 2x20, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x20_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x20 2.54mm double row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x21_P2.54mm_Horizontal +Through hole angled socket strip, 2x21, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinSocket_2.54mm +PinSocket_2x21_P2.54mm_Vertical +Through hole straight socket strip, 2x21, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinSocket_2.54mm +PinSocket_2x21_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x21 2.54mm double row +0 +42 +42 +Connector_PinSocket_2.54mm +PinSocket_2x22_P2.54mm_Horizontal +Through hole angled socket strip, 2x22, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinSocket_2.54mm +PinSocket_2x22_P2.54mm_Vertical +Through hole straight socket strip, 2x22, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinSocket_2.54mm +PinSocket_2x22_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x22 2.54mm double row +0 +44 +44 +Connector_PinSocket_2.54mm +PinSocket_2x23_P2.54mm_Horizontal +Through hole angled socket strip, 2x23, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinSocket_2.54mm +PinSocket_2x23_P2.54mm_Vertical +Through hole straight socket strip, 2x23, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinSocket_2.54mm +PinSocket_2x23_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x23 2.54mm double row +0 +46 +46 +Connector_PinSocket_2.54mm +PinSocket_2x24_P2.54mm_Horizontal +Through hole angled socket strip, 2x24, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinSocket_2.54mm +PinSocket_2x24_P2.54mm_Vertical +Through hole straight socket strip, 2x24, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinSocket_2.54mm +PinSocket_2x24_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x24 2.54mm double row +0 +48 +48 +Connector_PinSocket_2.54mm +PinSocket_2x25_P2.54mm_Horizontal +Through hole angled socket strip, 2x25, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinSocket_2.54mm +PinSocket_2x25_P2.54mm_Vertical +Through hole straight socket strip, 2x25, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinSocket_2.54mm +PinSocket_2x25_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x25 2.54mm double row +0 +50 +50 +Connector_PinSocket_2.54mm +PinSocket_2x26_P2.54mm_Horizontal +Through hole angled socket strip, 2x26, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinSocket_2.54mm +PinSocket_2x26_P2.54mm_Vertical +Through hole straight socket strip, 2x26, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinSocket_2.54mm +PinSocket_2x26_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x26 2.54mm double row +0 +52 +52 +Connector_PinSocket_2.54mm +PinSocket_2x27_P2.54mm_Horizontal +Through hole angled socket strip, 2x27, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinSocket_2.54mm +PinSocket_2x27_P2.54mm_Vertical +Through hole straight socket strip, 2x27, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinSocket_2.54mm +PinSocket_2x27_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x27 2.54mm double row +0 +54 +54 +Connector_PinSocket_2.54mm +PinSocket_2x28_P2.54mm_Horizontal +Through hole angled socket strip, 2x28, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinSocket_2.54mm +PinSocket_2x28_P2.54mm_Vertical +Through hole straight socket strip, 2x28, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinSocket_2.54mm +PinSocket_2x28_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x28 2.54mm double row +0 +56 +56 +Connector_PinSocket_2.54mm +PinSocket_2x29_P2.54mm_Horizontal +Through hole angled socket strip, 2x29, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinSocket_2.54mm +PinSocket_2x29_P2.54mm_Vertical +Through hole straight socket strip, 2x29, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinSocket_2.54mm +PinSocket_2x29_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x29 2.54mm double row +0 +58 +58 +Connector_PinSocket_2.54mm +PinSocket_2x30_P2.54mm_Horizontal +Through hole angled socket strip, 2x30, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinSocket_2.54mm +PinSocket_2x30_P2.54mm_Vertical +Through hole straight socket strip, 2x30, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinSocket_2.54mm +PinSocket_2x30_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x30 2.54mm double row +0 +60 +60 +Connector_PinSocket_2.54mm +PinSocket_2x31_P2.54mm_Horizontal +Through hole angled socket strip, 2x31, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinSocket_2.54mm +PinSocket_2x31_P2.54mm_Vertical +Through hole straight socket strip, 2x31, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinSocket_2.54mm +PinSocket_2x31_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x31 2.54mm double row +0 +62 +62 +Connector_PinSocket_2.54mm +PinSocket_2x32_P2.54mm_Horizontal +Through hole angled socket strip, 2x32, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinSocket_2.54mm +PinSocket_2x32_P2.54mm_Vertical +Through hole straight socket strip, 2x32, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinSocket_2.54mm +PinSocket_2x32_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x32 2.54mm double row +0 +64 +64 +Connector_PinSocket_2.54mm +PinSocket_2x33_P2.54mm_Horizontal +Through hole angled socket strip, 2x33, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinSocket_2.54mm +PinSocket_2x33_P2.54mm_Vertical +Through hole straight socket strip, 2x33, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinSocket_2.54mm +PinSocket_2x33_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x33 2.54mm double row +0 +66 +66 +Connector_PinSocket_2.54mm +PinSocket_2x34_P2.54mm_Horizontal +Through hole angled socket strip, 2x34, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinSocket_2.54mm +PinSocket_2x34_P2.54mm_Vertical +Through hole straight socket strip, 2x34, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinSocket_2.54mm +PinSocket_2x34_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x34 2.54mm double row +0 +68 +68 +Connector_PinSocket_2.54mm +PinSocket_2x35_P2.54mm_Horizontal +Through hole angled socket strip, 2x35, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinSocket_2.54mm +PinSocket_2x35_P2.54mm_Vertical +Through hole straight socket strip, 2x35, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinSocket_2.54mm +PinSocket_2x35_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x35 2.54mm double row +0 +70 +70 +Connector_PinSocket_2.54mm +PinSocket_2x36_P2.54mm_Horizontal +Through hole angled socket strip, 2x36, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinSocket_2.54mm +PinSocket_2x36_P2.54mm_Vertical +Through hole straight socket strip, 2x36, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinSocket_2.54mm +PinSocket_2x36_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x36 2.54mm double row +0 +72 +72 +Connector_PinSocket_2.54mm +PinSocket_2x37_P2.54mm_Horizontal +Through hole angled socket strip, 2x37, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinSocket_2.54mm +PinSocket_2x37_P2.54mm_Vertical +Through hole straight socket strip, 2x37, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinSocket_2.54mm +PinSocket_2x37_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x37 2.54mm double row +0 +74 +74 +Connector_PinSocket_2.54mm +PinSocket_2x38_P2.54mm_Horizontal +Through hole angled socket strip, 2x38, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinSocket_2.54mm +PinSocket_2x38_P2.54mm_Vertical +Through hole straight socket strip, 2x38, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinSocket_2.54mm +PinSocket_2x38_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x38 2.54mm double row +0 +76 +76 +Connector_PinSocket_2.54mm +PinSocket_2x39_P2.54mm_Horizontal +Through hole angled socket strip, 2x39, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinSocket_2.54mm +PinSocket_2x39_P2.54mm_Vertical +Through hole straight socket strip, 2x39, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinSocket_2.54mm +PinSocket_2x39_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x39 2.54mm double row +0 +78 +78 +Connector_PinSocket_2.54mm +PinSocket_2x40_P2.54mm_Horizontal +Through hole angled socket strip, 2x40, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinSocket_2.54mm +PinSocket_2x40_P2.54mm_Vertical +Through hole straight socket strip, 2x40, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinSocket_2.54mm +PinSocket_2x40_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x40 2.54mm double row +0 +80 +80 +Connector_RJ +RJ12_Amphenol_54601 +RJ12 connector https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/c-bmj-0082.pdf +RJ12 connector +0 +6 +6 +Connector_RJ +RJ14_Connfly_DS1133-S4_Horizontal +RJ14 connector 6P4C Horizontal http://www.connfly.com/userfiles/image/UpLoadFile/File/2012/10/26/DS1133.pdf +RJ14 connector 6P4C Connfly DS1133 +0 +4 +4 +Connector_RJ +RJ25_Wayconn_MJEA-660X1_Horizontal +RJ25 6P6C Socket 90 degrees, https://wayconn.com/wp-content/themes/way/datasheet/MJEA-660X1XXX_RJ25_6P6C_PCB_RA.pdf +RJ12 RJ18 RJ25 jack connector 6P6C +0 +6 +6 +Connector_RJ +RJ45_Abracon_ARJP11A-MA_Horizontal +Shielded RJ45 ethernet connector with transformer and POE (https://abracon.com/Magnetics/lan/ARJP11A.PDF) +ethernet 8p8c transformer poe rj45 +0 +15 +14 +Connector_RJ +RJ45_Amphenol_54602-x08_Horizontal +8 Pol Shallow Latch Connector, Modjack, RJ45 (https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/c-bmj-0102.pdf) +RJ45 +0 +8 +8 +Connector_RJ +RJ45_Amphenol_RJHSE538X +Shielded, 2 LED, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X.pdf +RJ45 8p8c ethernet cat5 +0 +14 +13 +Connector_RJ +RJ45_Amphenol_RJHSE538X-02 +Shielded, 2 LED, 2 Ports, http://www.amphenolinfocom.eu/NavData/Drawings/RJHSE-538X-02-REVC.pdf +RJ45 8p8c dual ethernet cat5 +0 +26 +25 +Connector_RJ +RJ45_Amphenol_RJHSE5380 +Shielded, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X.pdf +RJ45 8p8c ethernet cat5 +0 +10 +9 +Connector_RJ +RJ45_Amphenol_RJHSE5380-08 +Shielded, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X08.pdf +RJ45 8p8c ethernet cat5 +0 +68 +65 +Connector_RJ +RJ45_Amphenol_RJMG1BD3B8K1ANR +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, AutoMDIX, https://www.amphenolcanada.com/ProductSearch/Drawings/AC/RJMG1BD3B8K1ANR.PDF +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_BEL_SS74301-00x_Vertical +https://belfuse.com/resources/drawings/stewartconnector/dr-stw-ss-74301-001-ss-74301-002-ss-74301-005.pdf +RJ45 Vertical Shield LED Green Yellow +0 +14 +13 +Connector_RJ +RJ45_Cetus_J1B1211CCD_Horizontal +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, Cetus, used and distributed by WIZnet (https://wizwiki.net/wiki/lib/exe/fetch.php?media=products:wiz550web:wiz550webds_kr:j1b1211ccd.pdf) +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Hanrun_HR911105A +http://www.kosmodrom.com.ua/pdf/HR911105A.pdf +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Molex_0855135013_Vertical +1 Port, RJ45, Series 85513, vertical, SMD, https://www.molex.com/pdm_docs/sd/855135013_sd.pdf +RJ45 Vertical +0 +9 +9 +Connector_RJ +RJ45_Ninigi_GE +1 port ethernet throughhole connector, https://en.ninigi.com/product/rj45ge/pdf +RJ45 ethernet 8p8c +0 +10 +9 +Connector_RJ +RJ45_OST_PJ012-8P8CX_Vertical +RJ45 vertical connector https://www.on-shore.com/wp-content/uploads/PJ012-8P8CX.pdf +RJ45 PJ012 +0 +8 +8 +Connector_RJ +RJ45_Plug_Metz_AJP92A8813 +plug, ethernet, 8P8C, RJ45 Plug +AJP92A8813 8P8C RJ45 ethernet plug +0 +8 +8 +Connector_RJ +RJ45_Pulse_JK0654219NL_Horizontal +10/100/1000 Base-T RJ45 single port with LEDs https://media.digikey.com/pdf/Data%20Sheets/Pulse%20PDFs/JK%20Series.pdf#page=2 +RJ45 8p8c ethernet +0 +18 +17 +Connector_RJ +RJ45_Pulse_JXD6-0001NL_Horizontal +RJ45 ethernet transformer with magnetics (https://productfinder.pulseeng.com/doc_type/WEB301/doc_num/JXD6-0001NL/doc_part/JXD6-0001NL.pdf) +ethernet 8p8c transformer magjack +0 +12 +11 +Connector_RJ +RJ45_Wuerth_7499010001A_Horizontal +10/100Base-TX RJ45 ethernet magnetic transformer connector horizontal https://katalog.we-online.de/pbs/datasheet/7499010001A.pdf +RJ45 ethernet magnetic +0 +10 +9 +Connector_RJ +RJ45_Wuerth_7499010121A_Horizontal +10/100Base-TX RJ45 ethernet magnetic transformer connector horizontal with green/orange LEDs https://katalog.we-online.de/pbs/datasheet/7499010121A.pdf +RJ45 ethernet magnetic +0 +14 +13 +Connector_RJ +RJ45_Wuerth_7499111446_Horizontal +LAN-Transformer WE-RJ45LAN 10/100/1000 BaseT +ethernet lan connector +0 +16 +15 +Connector_RJ +RJ45_Wuerth_7499151120_Horizontal +Wuerth 7499151120, LAN-Transformer WE-RJ45LAN 10/100/1000 BaseT, Dual Ethernet Jack (http://katalog.we-online.de/pbs/datasheet/7499151120.pdf) +ethernet lan connector +0 +32 +29 +Connector_RJ +RJ45_Wuerth_74980111211_Horizontal +RJ45 LAN Transformer 10/100BaseT (https://katalog.we-online.de/pbs/datasheet/74980111211.pdf) +lan magnetics transformer +0 +14 +13 +Connector_SATA_SAS +SAS-mini_TEConnectivity_1888174_Vertical +36pin mini SAS connector, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=1888174&DocType=Customer+Drawing&DocLang=English +SAS mini connector +0 +44 +44 +Connector_SATA_SAS +SATA_Amphenol_10029364-001LF_Horizontal +https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10029364.pdf +SATA +0 +24 +23 +Connector_Samtec +Samtec_FMC_ASP-134486-01_10x40_P1.27mm_Vertical +http://suddendocs.samtec.com/prints/asp-134486-01-mkt.pdf +FMC HPC +0 +400 +400 +Connector_Samtec +Samtec_FMC_ASP-134602-01_10x40_P1.27mm_Vertical +https://www.marutsu.co.jp/contents/shop/marutsu/ds/asp-134602-01.pdf +FMC HPC +0 +400 +400 +Connector_Samtec +Samtec_FMC_ASP-134604-01_4x40_Vertical +http://www.samtec.com/standards/vita.aspx +FMC LPC VITA +0 +162 +160 +Connector_Samtec +Samtec_LSHM-105-xx.x-x-DV-N_2x05_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-105-xx.x-x-DV-N, 5 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +10 +10 +Connector_Samtec +Samtec_LSHM-105-xx.x-x-DV-S_2x05-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-105-xx.x-x-DV-S, 5 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +12 +11 +Connector_Samtec +Samtec_LSHM-110-xx.x-x-DV-N_2x10_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-110-xx.x-x-DV-N, 10 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +20 +20 +Connector_Samtec +Samtec_LSHM-110-xx.x-x-DV-S_2x10-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-110-xx.x-x-DV-S, 10 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +22 +21 +Connector_Samtec +Samtec_LSHM-120-xx.x-x-DV-N_2x20_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-120-xx.x-x-DV-N, 20 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +40 +40 +Connector_Samtec +Samtec_LSHM-120-xx.x-x-DV-S_2x20-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-120-xx.x-x-DV-S, 20 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +42 +41 +Connector_Samtec +Samtec_LSHM-130-xx.x-x-DV-N_2x30_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-130-xx.x-x-DV-N, 30 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +60 +60 +Connector_Samtec +Samtec_LSHM-130-xx.x-x-DV-S_2x30-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-130-xx.x-x-DV-S, 30 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +62 +61 +Connector_Samtec +Samtec_LSHM-140-xx.x-x-DV-N_2x40_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-140-xx.x-x-DV-N, 40 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +80 +80 +Connector_Samtec +Samtec_LSHM-140-xx.x-x-DV-S_2x40-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-140-xx.x-x-DV-S, 40 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +82 +81 +Connector_Samtec +Samtec_LSHM-150-xx.x-x-DV-N_2x50_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-150-xx.x-x-DV-N, 50 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +100 +100 +Connector_Samtec +Samtec_LSHM-150-xx.x-x-DV-S_2x50-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-150-xx.x-x-DV-S, 50 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +102 +101 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV-BE-LC_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV-BE-LC, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV-BE_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV-BE, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV-LC_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV-LC, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV-BE-LC_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV-BE-LC, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV-BE_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV-BE, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV-LC_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV-LC, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-A_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-A, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-BE-A_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-BE-A, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-BE-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-BE-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-BE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-BE, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-A_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-A, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-BE-A_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-BE-A, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-BE-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-BE-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-BE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-BE, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-A_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-A, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-BE-A_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-BE-A, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-BE-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-BE-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-BE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-BE, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-A_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-A, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-BE-A_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-BE-A, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-BE-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-BE-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-BE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-BE, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-A_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-A, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-BE-A_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-BE-A, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-BE-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-BE-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-BE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-BE, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-A_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-A, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-BE-A_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-BE-A, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-BE-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-BE-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-BE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-BE, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-A_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-A, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-BE-A_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-BE-A, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-BE-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-BE-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-BE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-BE, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-A_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-A, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-BE-A_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-BE-A, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-BE-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-BE-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-BE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-BE, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-A_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-A, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-BE-A_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-BE-A, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-BE-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-BE-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-BE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-BE, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-A_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-A, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-BE-A_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-BE-A, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-BE-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-BE-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-BE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-BE, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-A_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-A, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-BE-A_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-BE-A, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-BE-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-BE-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-BE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-BE, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-A_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-A, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-BE-A_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-BE-A, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-BE-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-BE-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-BE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-BE, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-A_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-A, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-BE-A_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-BE-A, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-BE-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-BE-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-BE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-BE, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-A_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-A, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-BE-A_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-BE-A, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-BE-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-BE-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-BE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-BE, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-A_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-A, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-BE-A_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-BE-A, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-BE-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-BE-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-BE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-BE, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-A_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-A, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-BE-A_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-BE-A, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-BE-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-BE-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-BE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-BE, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-A_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-A, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-BE-A_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-BE-A, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-BE-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-BE-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-BE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-BE, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-A_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-A, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-BE-A_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-BE-A, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-BE-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-BE-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-BE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-BE, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-A_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-A, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-BE-A_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-BE-A, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-BE-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-BE-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-BE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-BE, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-A_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-A, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-BE-A_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-BE-A, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-BE-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-BE-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-BE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-BE, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-A_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-A, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-BE-A_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-BE-A, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-BE-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-BE-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-BE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-BE, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-A_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-A, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-BE-A_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-BE-A, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-BE-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-BE-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-BE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-BE, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-A_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-A, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-BE-A_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-BE-A, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-BE-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-BE-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-BE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-BE, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-A_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-A, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-BE-A_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-BE-A, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-BE-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-BE-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-BE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-BE, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-A_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-A, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-BE-A_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE-A, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-BE-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-BE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-A_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-A, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-BE-A_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-BE-A, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-BE-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-BE-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-BE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-BE, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-A_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-A, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-BE-A_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-BE-A, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-BE-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-BE-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-BE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-BE, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-A_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-A, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-BE-A_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-BE-A, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-BE-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-BE-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-BE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-BE, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-A_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-A, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-BE-A_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-BE-A, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-BE-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-BE-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-BE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-BE, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-A_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-A, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-BE-A_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-BE-A, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-BE-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-BE-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-BE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-BE, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-A_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-A, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-BE-A_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-BE-A, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-BE-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-BE-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-BE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-BE, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-A_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-A, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-BE-A_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-BE-A, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-BE-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-BE-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-BE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-BE, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-A_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-A, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-BE-A_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-BE-A, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-BE-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-BE-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-BE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-BE, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-A_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-A, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-BE-A_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-BE-A, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-BE-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-BE-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-BE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-BE, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-A_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-A, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-BE-A_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-BE-A, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-BE-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-BE-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-BE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-BE, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-A_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-A, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-BE-A_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-BE-A, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-BE-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-BE-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-BE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-BE, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-A_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-A, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-BE-A_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-BE-A, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-BE-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-BE-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-BE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-BE, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-A_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-A, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-BE-A_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-BE-A, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-BE-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-BE-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-BE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-BE, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-A_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-A, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-BE-A_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-BE-A, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-BE-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-BE-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-BE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-BE, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-A_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-A, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-BE-A_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-BE-A, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-BE-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-BE-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-BE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-BE, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-A_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-A, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-BE-A_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-BE-A, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-BE-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-BE-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-BE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-BE, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-A_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-A, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-BE-A_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-BE-A, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-BE-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-BE-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-BE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-BE, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-A_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-A, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-BE-A_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-BE-A, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-BE-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-BE-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-BE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-BE, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-A_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-A, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-BE-A_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-BE-A, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-BE-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-BE-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-BE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-BE, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-A_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-A, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-BE-A_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-BE-A, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-BE-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-BE-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-BE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-BE, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-A_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-A, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-BE-A_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-BE-A, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-BE-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-BE-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-BE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-BE, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-A_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-A, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-BE-A_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-BE-A, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-BE-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-BE-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-BE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-BE, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-PE-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-PE-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-PE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-PE (compatible alternatives: HLE-104-02-xx-DV-PE-BE), 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-TE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-TE, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-PE-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-PE-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-PE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-PE (compatible alternatives: HLE-105-02-xx-DV-PE-BE), 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-TE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-TE, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-PE-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-PE-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-PE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-PE (compatible alternatives: HLE-106-02-xx-DV-PE-BE), 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-TE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-TE, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-PE-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-PE-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-PE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-PE (compatible alternatives: HLE-107-02-xx-DV-PE-BE), 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-TE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-TE, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-PE-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-PE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE (compatible alternatives: HLE-108-02-xx-DV-PE-BE), 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-TE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-TE, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-PE-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-PE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE (compatible alternatives: HLE-109-02-xx-DV-PE-BE), 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-TE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-TE, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-PE-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-PE-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-PE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-PE (compatible alternatives: HLE-110-02-xx-DV-PE-BE), 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-TE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-TE, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-PE-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-PE-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-PE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-PE (compatible alternatives: HLE-111-02-xx-DV-PE-BE), 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-TE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-TE, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-PE-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-PE-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-PE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-PE (compatible alternatives: HLE-112-02-xx-DV-PE-BE), 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-TE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-TE, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-PE-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-PE-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-PE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-PE (compatible alternatives: HLE-113-02-xx-DV-PE-BE), 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-TE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-TE, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-PE-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-PE-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-PE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-PE (compatible alternatives: HLE-114-02-xx-DV-PE-BE), 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-TE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-TE, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-PE-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-PE-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-PE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-PE (compatible alternatives: HLE-115-02-xx-DV-PE-BE), 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-TE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-TE, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-PE-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-PE-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-PE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-PE (compatible alternatives: HLE-116-02-xx-DV-PE-BE), 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-TE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-TE, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-PE-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-PE-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-PE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-PE (compatible alternatives: HLE-117-02-xx-DV-PE-BE), 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-TE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-TE, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-PE-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-PE-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-PE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-PE (compatible alternatives: HLE-118-02-xx-DV-PE-BE), 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-TE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-TE, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-PE-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-PE-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-PE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-PE (compatible alternatives: HLE-119-02-xx-DV-PE-BE), 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-TE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-TE, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-PE-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-PE-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-PE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-PE (compatible alternatives: HLE-120-02-xx-DV-PE-BE), 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-TE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-TE, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-PE-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-PE-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-PE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-PE (compatible alternatives: HLE-121-02-xx-DV-PE-BE), 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-TE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-TE, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-PE-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-PE-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-PE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-PE (compatible alternatives: HLE-122-02-xx-DV-PE-BE), 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-TE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-TE, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-PE-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-PE-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-PE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-PE (compatible alternatives: HLE-123-02-xx-DV-PE-BE), 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-TE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-TE, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-PE-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-PE-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-PE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-PE (compatible alternatives: HLE-124-02-xx-DV-PE-BE), 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-TE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-TE, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-PE-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-PE-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-PE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-PE (compatible alternatives: HLE-125-02-xx-DV-PE-BE), 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-TE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-TE, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-PE-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-PE-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-PE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-PE (compatible alternatives: HLE-126-02-xx-DV-PE-BE), 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-TE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-TE, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-PE-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-PE-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-PE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-PE (compatible alternatives: HLE-127-02-xx-DV-PE-BE), 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-TE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-TE, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-PE-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-PE-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-PE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-PE (compatible alternatives: HLE-128-02-xx-DV-PE-BE), 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-TE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-TE, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-PE-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-PE-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-PE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-PE (compatible alternatives: HLE-129-02-xx-DV-PE-BE), 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-TE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-TE, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-PE-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-PE-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-PE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-PE (compatible alternatives: HLE-130-02-xx-DV-PE-BE), 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-TE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-TE, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-PE-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-PE-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-PE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-PE (compatible alternatives: HLE-131-02-xx-DV-PE-BE), 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-TE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-TE, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-PE-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-PE-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-PE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-PE (compatible alternatives: HLE-132-02-xx-DV-PE-BE), 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-TE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-TE, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-PE-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-PE-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-PE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-PE (compatible alternatives: HLE-133-02-xx-DV-PE-BE), 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-TE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-TE, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-PE-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-PE-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-PE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-PE (compatible alternatives: HLE-134-02-xx-DV-PE-BE), 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-TE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-TE, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-PE-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-PE-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-PE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-PE (compatible alternatives: HLE-135-02-xx-DV-PE-BE), 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-TE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-TE, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-PE-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-PE-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-PE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-PE (compatible alternatives: HLE-136-02-xx-DV-PE-BE), 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-TE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-TE, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-PE-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-PE-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-PE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-PE (compatible alternatives: HLE-137-02-xx-DV-PE-BE), 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-TE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-TE, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-PE-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-PE-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-PE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-PE (compatible alternatives: HLE-138-02-xx-DV-PE-BE), 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-TE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-TE, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-PE-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-PE-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-PE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-PE (compatible alternatives: HLE-139-02-xx-DV-PE-BE), 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-TE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-TE, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-PE-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-PE-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-PE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-PE (compatible alternatives: HLE-140-02-xx-DV-PE-BE), 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-TE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-TE, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-PE-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-PE-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-PE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-PE (compatible alternatives: HLE-141-02-xx-DV-PE-BE), 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-TE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-TE, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-PE-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-PE-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-PE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-PE (compatible alternatives: HLE-142-02-xx-DV-PE-BE), 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-TE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-TE, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-PE-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-PE-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-PE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-PE (compatible alternatives: HLE-143-02-xx-DV-PE-BE), 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-TE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-TE, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-PE-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-PE-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-PE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-PE (compatible alternatives: HLE-144-02-xx-DV-PE-BE), 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-TE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-TE, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-PE-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-PE-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-PE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-PE (compatible alternatives: HLE-145-02-xx-DV-PE-BE), 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-TE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-TE, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-PE-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-PE-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-PE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-PE (compatible alternatives: HLE-146-02-xx-DV-PE-BE), 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-TE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-TE, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-PE-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-PE-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-PE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-PE (compatible alternatives: HLE-147-02-xx-DV-PE-BE), 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-TE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-TE, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-PE-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-PE-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-PE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-PE (compatible alternatives: HLE-148-02-xx-DV-PE-BE), 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-TE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-TE, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-PE-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-PE-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-PE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-PE (compatible alternatives: HLE-149-02-xx-DV-PE-BE), 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-TE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-TE, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-PE-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-PE-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-PE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-PE (compatible alternatives: HLE-150-02-xx-DV-PE-BE), 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-TE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-TE, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Stocko +Stocko_MKS_1651-6-0-202_1x2_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +2 +2 +Connector_Stocko +Stocko_MKS_1652-6-0-202_1x2_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +2 +2 +Connector_Stocko +Stocko_MKS_1653-6-0-303_1x3_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +3 +3 +Connector_Stocko +Stocko_MKS_1654-6-0-404_1x4_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +4 +4 +Connector_Stocko +Stocko_MKS_1655-6-0-505_1x5_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +5 +5 +Connector_Stocko +Stocko_MKS_1656-6-0-606_1x6_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +6 +6 +Connector_Stocko +Stocko_MKS_1657-6-0-707_1x7_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +7 +7 +Connector_Stocko +Stocko_MKS_1658-6-0-808_1x8_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +8 +8 +Connector_Stocko +Stocko_MKS_1659-6-0-909_1x9_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +9 +9 +Connector_Stocko +Stocko_MKS_1660-6-0-1010_1x10_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +10 +10 +Connector_Stocko +Stocko_MKS_1661-6-0-1111_1x11_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +11 +11 +Connector_Stocko +Stocko_MKS_1662-6-0-1212_1x12_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +12 +12 +Connector_Stocko +Stocko_MKS_1663-6-0-1313_1x13_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +13 +13 +Connector_Stocko +Stocko_MKS_1664-6-0-1414_1x14_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +14 +14 +Connector_Stocko +Stocko_MKS_1665-6-0-1515_1x15_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +15 +15 +Connector_Stocko +Stocko_MKS_1666-6-0-1616_1x16_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +16 +16 +Connector_Stocko +Stocko_MKS_1667-6-0-1717_1x17_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +17 +17 +Connector_Stocko +Stocko_MKS_1668-6-0-1818_1x18_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +18 +18 +Connector_Stocko +Stocko_MKS_1669-6-0-1919_1x19_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +19 +19 +Connector_Stocko +Stocko_MKS_1670-6-0-2020_1x20_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +20 +20 +Connector_TE-Connectivity +TE_1-826576-3_1x13_P3.96mm_Vertical +TE, 1-826576-3, 13 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +13 +13 +Connector_TE-Connectivity +TE_1-826576-5_1x15_P3.96mm_Vertical +TE, 1-826576-5, 15 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +15 +15 +Connector_TE-Connectivity +TE_1-826576-6_1x16_P3.96mm_Vertical +TE, 1-826576-6, 16 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +16 +16 +Connector_TE-Connectivity +TE_1-826576-7_1x17_P3.96mm_Vertical +TE, 1-826576-7, 17 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +17 +17 +Connector_TE-Connectivity +TE_1-826576-8_1x18_P3.96mm_Vertical +TE, 1-826576-8, 18 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +18 +18 +Connector_TE-Connectivity +TE_2-826576-0_1x20_P3.96mm_Vertical +TE, 2-826576-0, 20 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +20 +20 +Connector_TE-Connectivity +TE_3-826576-6_1x36_P3.96mm_Vertical +TE, 3-826576-6, 36 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +36 +36 +Connector_TE-Connectivity +TE_826576-2_1x02_P3.96mm_Vertical +TE, 826576-2, 2 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +2 +2 +Connector_TE-Connectivity +TE_826576-3_1x03_P3.96mm_Vertical +TE, 826576-3, 3 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +3 +3 +Connector_TE-Connectivity +TE_826576-5_1x05_P3.96mm_Vertical +TE, 826576-5, 5 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +5 +5 +Connector_TE-Connectivity +TE_826576-6_1x06_P3.96mm_Vertical +TE, 826576-6, 6 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +6 +6 +Connector_TE-Connectivity +TE_826576-7_1x07_P3.96mm_Vertical +TE, 826576-7, 7 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +7 +7 +Connector_TE-Connectivity +TE_826576-8_1x08_P3.96mm_Vertical +TE, 826576-8, 8 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +8 +8 +Connector_TE-Connectivity +TE_826576-9_1x09_P3.96mm_Vertical +TE, 826576-9, 9 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +9 +9 +Connector_TE-Connectivity +TE_5767171-1_2x19_P0.635mm_Vertical +PCB Mount Receptacle, Vertical, Board-to-Board, 38 Position, 24.003mm / .64mm [.945in] Centerline, Header Only, Palladium Nickel (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F5767171%7FB2%7Fpdf%7FEnglish%7FENG_CD_5767171_B2.pdf%7F5767171-1#page=2) +mictor38 receptacle board-to-board +0 +43 +39 +Connector_TE-Connectivity +TE_AMPSEAL_1-776087-x_3Rows_23_P0.4mm_Horizontal +Connector +TE 776087 +0 +23 +23 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770182-x_3x03_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770182-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +9 +9 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770186-x_3x04_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770186-x, 4 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +12 +12 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770190-x_3x05_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770190-x, 5 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +15 +15 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770621-x_2x06_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770621-x, 6 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +12 +12 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770858-x_2x05_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770858-x, 5 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +10 +10 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770866-x_1x02_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770866-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +2 +2 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770870-x_1x03_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770870-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +3 +3 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770874-x_2x02_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770874-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +4 +4 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770875-x_2x03_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770875-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +6 +6 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770966-x_1x02_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770966-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +2 +2 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770967-x_1x03_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770967-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +3 +3 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770968-x_2x02_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770968-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +4 +4 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770969-x_2x03_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770969-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +6 +6 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770970-x_2x04_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770970-x, 4 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +8 +8 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770971-x_2x05_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770971-x, 5 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +10 +10 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770972-x_2x06_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770972-x, 6 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +12 +12 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770973-x_2x07_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770973-x, 7 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +14 +14 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770974-x_2x08_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770974-x, 8 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +16 +16 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794067-x_2x07_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794067-x, 7 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +14 +14 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794068-x_2x08_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794068-x, 8 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +16 +16 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794069-x_2x09_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794069-x, 9 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +18 +18 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794070-x_2x10_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794070-x, 10 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +20 +20 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794071-x_2x11_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794071-x, 11 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +22 +22 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794072-x_2x12_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794072-x, 12 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +24 +24 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794073-x_2x04_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794073-x, 4 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +8 +8 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794105-x_2x09_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794105-x, 9 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +18 +18 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794106-x_2x10_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794106-x, 10 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +20 +20 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794107-x_2x11_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794107-x, 11 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +22 +22 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794108-x_2x12_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794108-x, 12 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +24 +24 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794374-x_1x01_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794374-x, 1 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +1 +1 +Connector_TE-Connectivity +TE_MATE-N-LOK_350211-1_1x04_P5.08mm_Vertical +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F350211%7FU5%7Fpdf%7FEnglish%7FENG_CD_350211_U5.pdf%7F350211-1 +connector TE MATE-N-LOK top entry ATA PATA IDE 5.25 inch floppy drive power +0 +4 +4 +Connector_USB +USB3_A_Molex_48393-001 +USB 3.0, type A, right angle (http://www.molex.com/pdm_docs/sd/483930003_sd.pdf) +USB 3.0 type A right angle +0 +13 +10 +Connector_USB +USB3_A_Plug_Wuerth_692112030100_Horizontal +USB3 type A Plug, Horizontal, http://katalog.we-online.de/em/datasheet/692112030100.pdf +usb A plug horizontal +0 +11 +10 +Connector_USB +USB_A_CNCTech_1001-011-01101_Horizontal +USB type A Plug, Horizontal, http://cnctech.us/pdfs/1001-011-01101.pdf +USB-A +0 +6 +5 +Connector_USB +USB_A_CONNFLY_DS1095-WNR0 +http://www.connfly.com/userfiles/image/UpLoadFile/File/2013/5/6/DS1095.pdf +USB-A receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_A_Molex_67643_Horizontal +USB type A, Horizontal, https://www.molex.com/pdm_docs/sd/676433910_sd.pdf +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_Molex_105057_Vertical +https://www.molex.com/pdm_docs/sd/1050570001_sd.pdf +USB A Vertical +0 +7 +5 +Connector_USB +USB_A_Stewart_SS-52100-001_Horizontal +USB A connector https://belfuse.com/resources/drawings/stewartconnector/dr-stw-ss-52100-001.pdf +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_Wuerth_614004134726_Horizontal +USB A connector https://www.we-online.com/catalog/datasheet/614004134726.pdf +USB_A Female Connector receptacle +0 +8 +5 +Connector_USB +USB_A_Wuerth_61400826021_Horizontal_Stacked +Stacked USB A connector http://katalog.we-online.de/em/datasheet/61400826021.pdf +Wuerth stacked USB_A +0 +12 +9 +Connector_USB +USB_B_Amphenol_MUSB-D511_Vertical_Rugged +A,phenol MUSB_D511, USB B female connector, straight, rugged, https://www.amphenolcanada.com/ProductSearch/drawings/AC/MUSBD511XX.pdf +USB_B_MUSB_Straight female connector straight rugged MUSB D511 +0 +6 +5 +Connector_USB +USB_B_Lumberg_2411_02_Horizontal +USB 2.0 receptacle type B, horizontal version, through-hole, https://downloads.lumberg.com/datenblaetter/en/2411_02.pdf +USB B receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_B_OST_USB-B1HSxx_Horizontal +USB B receptacle, Horizontal, through-hole, http://www.on-shore.com/wp-content/uploads/2015/09/usb-b1hsxx.pdf +USB-B receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_B_TE_5787834_Vertical +http://www.mouser.com/ds/2/418/NG_CD_5787834_A4-669110.pdf +USB_B USB B vertical female connector +0 +6 +5 +Connector_USB +USB_C_Plug_JAE_DX07P024AJ1 +Universal Serial Bus (USB) Shielded I/O Plug, Type C, Right Angle, Surface Mount, https://www.jae.com/en/searchfilter/?topics_keyword=DX07P024AJ1&mainItemSelect=1 +USB Type-C Plug Edge Mount +0 +30 +25 +Connector_USB +USB_C_Plug_Molex_105444 +Universal Serial Bus (USB) Shielded I/O Plug, Type C, Right Angle, Surface Mount, http://www.molex.com/pdm_docs/sd/1054440001_sd.pdf +USB Type-C Plug Edge Mount +0 +24 +23 +Connector_USB +USB_C_Receptacle_Amphenol_12401548E4-2A +USB TYPE C, RA RCPT PCB, Hybrid, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401548E4%7e2A +USB C Type-C Receptacle Hybrid +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401548E4-2A_CircularHoles +USB TYPE C, RA RCPT PCB, Hybrid, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401548E4%7e2A +USB C Type-C Receptacle Hybrid +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401610E4-2A +USB TYPE C, RA RCPT PCB, SMT, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401610E4%7e2A +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401610E4-2A_CircularHoles +USB TYPE C, RA RCPT PCB, SMT, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401610E4%7e2A +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_GCT_USB4085 +USB 2.0 Type C Receptacle, https://gct.co/Files/Drawings/USB4085.pdf +USB Type-C Receptacle Through-hole Right angle +0 +20 +17 +Connector_USB +USB_C_Receptacle_HRO_TYPE-C-31-M-12 +USB Type-C receptacle for USB 2.0 and PD, http://www.krhro.com/uploads/soft/180320/1-1P320120243.pdf +usb usb-c 2.0 pd +0 +20 +17 +Connector_USB +USB_C_Receptacle_JAE_DX07S024WJ1R350 +http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ117219.pdf +USB C Type-C Receptacle SMD +0 +30 +25 +Connector_USB +USB_C_Receptacle_JAE_DX07S024WJ3R400 +USB TYPE C, VERT RCPT PCB, SMT, http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ117928.pdf +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_Palconn_UTC16-G +http://www.palpilot.com/wp-content/uploads/2017/05/UTC027-GKN-OR-Rev-A.pdf +USB C Type-C Receptacle USB2.0 +0 +20 +17 +Connector_USB +USB_C_Receptacle_XKB_U262-16XN-4BVC11 +USB Type C, right-angle, SMT, https://datasheet.lcsc.com/szlcsc/1811141824_XKB-Enterprise-U262-161N-4BVC11_C319148.pdf +USB C Type-C Receptacle SMD +0 +20 +17 +Connector_USB +USB_Micro-AB_Molex_47590-0001 +Micro USB AB receptable, right-angle inverted (https://www.molex.com/pdm_docs/sd/475900001_sd.pdf) +Micro AB USB SMD +0 +14 +6 +Connector_USB +USB_Micro-B_Amphenol_10103594-0001LF_Horizontal +Micro USB Type B 10103594-0001LF, http://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10103594.pdf +USB USB_B USB_micro USB_OTG +0 +17 +6 +Connector_USB +USB_Micro-B_Amphenol_10104110_Horizontal +USB Micro-B, horizontal, https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10104110.pdf +USB Micro B horizontal +0 +9 +6 +Connector_USB +USB_Micro-B_Amphenol_10118194_Horizontal +USB Micro-B receptacle, horizontal, SMD, 10118194, https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10118194.pdf +USB Micro B horizontal SMD +0 +17 +6 +Connector_USB +USB_Micro-B_GCT_USB3076-30-A +GCT Micro USB https://gct.co/files/drawings/usb3076.pdf +Micro-USB SMD Typ-B GCT +0 +11 +6 +Connector_USB +USB_Micro-B_Molex-105017-0001 +http://www.molex.com/pdm_docs/sd/1050170001_sd.pdf +Micro-USB SMD Typ-B +0 +13 +6 +Connector_USB +USB_Micro-B_Molex-105133-0001 +Molex Vertical Micro USB Typ-B (http://www.molex.com/pdm_docs/sd/1051330001_sd.pdf) +Micro-USB SMD Typ-B Vertical +0 +8 +6 +Connector_USB +USB_Micro-B_Molex-105133-0031 +Molex Vertical Micro USB Typ-B (http://www.molex.com/pdm_docs/sd/1051330031_sd.pdf) +Micro-USB SMD Typ-B Vertical +0 +8 +6 +Connector_USB +USB_Micro-B_Molex_47346-0001 +Micro USB B receptable with flange, bottom-mount, SMD, right-angle (http://www.molex.com/pdm_docs/sd/473460001_sd.pdf) +Micro B USB SMD +0 +11 +6 +Connector_USB +USB_Micro-B_Wuerth_614105150721_Vertical +USB Micro-B receptacle, through-hole, vertical, http://katalog.we-online.de/em/datasheet/614105150721.pdf +usb micro receptacle vertical +0 +7 +6 +Connector_USB +USB_Micro-B_Wuerth_614105150721_Vertical_CircularHoles +USB Micro-B receptacle, through-hole, vertical, http://katalog.we-online.de/em/datasheet/614105150721.pdf +usb micro receptacle vertical +0 +7 +6 +Connector_USB +USB_Micro-B_Wuerth_629105150521 +USB Micro-B receptacle, http://www.mouser.com/ds/2/445/629105150521-469306.pdf +usb micro receptacle +0 +9 +6 +Connector_USB +USB_Micro-B_Wuerth_629105150521_CircularHoles +USB Micro-B receptacle, http://www.mouser.com/ds/2/445/629105150521-469306.pdf +usb micro receptacle +0 +9 +6 +Connector_USB +USB_Mini-B_AdamTech_MUSB-B5-S-VT-TSMT-1_SMD_Vertical +http://www.adam-tech.com/upload/MUSB-B5-S-VT-TSMT-1.pdf +USB Mini-B +0 +7 +6 +Connector_USB +USB_Mini-B_Lumberg_2486_01_Horizontal +USB Mini-B 5-pin SMD connector, http://downloads.lumberg.com/datenblaetter/en/2486_01.pdf +USB USB_B USB_Mini connector +0 +9 +6 +Connector_USB +USB_Mini-B_Tensility_54-00023_Vertical +http://www.tensility.com/pdffiles/54-00023.pdf +usb mini receptacle vertical +0 +7 +6 +Connector_USB +USB_Mini-B_Tensility_54-00023_Vertical_CircularHoles +http://www.tensility.com/pdffiles/54-00023.pdf +usb mini receptacle vertical +0 +7 +6 +Connector_USB +USB_Mini-B_Wuerth_65100516121_Horizontal +Mini USB 2.0 Type B SMT Horizontal 5 Contacts (https://katalog.we-online.de/em/datasheet/65100516121.pdf) +Mini USB 2.0 Type B +0 +9 +6 +Connector_Wago +Wago_734-132_1x02_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-132 , 2 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +2 +2 +Connector_Wago +Wago_734-133_1x03_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-133 , 3 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +3 +3 +Connector_Wago +Wago_734-134_1x04_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-134 , 4 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +4 +4 +Connector_Wago +Wago_734-135_1x05_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-135 , 5 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +5 +5 +Connector_Wago +Wago_734-136_1x06_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-136 , 6 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +6 +6 +Connector_Wago +Wago_734-137_1x07_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-137 , 7 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +7 +7 +Connector_Wago +Wago_734-138_1x08_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-138 , 8 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +8 +8 +Connector_Wago +Wago_734-139_1x09_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-139 , 9 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +9 +9 +Connector_Wago +Wago_734-140_1x10_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-140 , 10 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +10 +10 +Connector_Wago +Wago_734-141_1x11_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-141 , 11 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +11 +11 +Connector_Wago +Wago_734-142_1x12_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-142 , 12 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +12 +12 +Connector_Wago +Wago_734-143_1x13_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-143 , 13 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +13 +13 +Connector_Wago +Wago_734-144_1x14_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-144 , 14 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +14 +14 +Connector_Wago +Wago_734-146_1x16_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-146 , 16 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +16 +16 +Connector_Wago +Wago_734-148_1x18_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-148 , 18 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +18 +18 +Connector_Wago +Wago_734-150_1x20_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-150 , 20 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +20 +20 +Connector_Wago +Wago_734-154_1x24_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-154 , 24 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +24 +24 +Connector_Wago +Wago_734-162_1x02_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-162 , 2 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +2 +2 +Connector_Wago +Wago_734-163_1x03_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-163 , 3 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +3 +3 +Connector_Wago +Wago_734-164_1x04_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-164 , 4 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +4 +4 +Connector_Wago +Wago_734-165_1x05_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-165 , 5 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +5 +5 +Connector_Wago +Wago_734-166_1x06_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-166 , 6 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +6 +6 +Connector_Wago +Wago_734-167_1x07_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-167 , 7 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +7 +7 +Connector_Wago +Wago_734-168_1x08_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-168 , 8 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +8 +8 +Connector_Wago +Wago_734-169_1x09_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-169 , 9 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +9 +9 +Connector_Wago +Wago_734-170_1x10_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-170 , 10 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +10 +10 +Connector_Wago +Wago_734-171_1x11_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-171 , 11 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +11 +11 +Connector_Wago +Wago_734-172_1x12_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-172 , 12 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +12 +12 +Connector_Wago +Wago_734-173_1x13_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-173 , 13 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +13 +13 +Connector_Wago +Wago_734-174_1x14_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-174 , 14 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +14 +14 +Connector_Wago +Wago_734-176_1x16_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-176 , 16 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +16 +16 +Connector_Wago +Wago_734-178_1x18_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-178 , 18 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +18 +18 +Connector_Wago +Wago_734-180_1x20_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-180 , 20 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +20 +20 +Connector_Wago +Wago_734-184_1x24_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-184 , 24 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +24 +24 +Connector_Wire +SolderWire-0.1sqmm_1x01_D0.4mm_OD1mm +Soldered wire connection, for a single 0.1 mm² wire, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.1sqmm_1x01_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.1 mm² wire, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.1sqmm_1x01_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.1 mm² wire, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.1sqmm_1x02_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 2 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.1sqmm_1x02_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.1sqmm_1x02_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.1sqmm_1x03_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 3 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.1sqmm_1x03_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.1sqmm_1x03_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.1sqmm_1x04_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 4 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.1sqmm_1x04_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.1sqmm_1x04_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.1sqmm_1x05_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 5 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.1sqmm_1x05_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.1sqmm_1x05_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.1sqmm_1x06_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 6 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.1sqmm_1x06_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.1sqmm_1x06_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.1mm +Soldered wire connection, for a single 0.5 mm² wire, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.5 mm² wire, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.5 mm² wire, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.3mm +Soldered wire connection, for a single 0.5 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.5 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.5 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 2 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 2 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 3 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 3 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 4 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 4 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 5 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 6 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.15sqmm_1x01_D0.5mm_OD1.5mm +Soldered wire connection, for a single 0.15 mm² wire, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.15sqmm_1x01_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.15 mm² wire, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.15sqmm_1x01_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.15 mm² wire, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.15sqmm_1x02_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 2 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.15sqmm_1x02_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.15sqmm_1x02_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.15sqmm_1x03_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 3 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.15sqmm_1x03_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.15sqmm_1x03_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.15sqmm_1x04_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 4 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.15sqmm_1x04_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.15sqmm_1x04_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.15sqmm_1x05_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 5 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.15sqmm_1x05_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.15sqmm_1x05_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.15sqmm_1x06_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 6 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.15sqmm_1x06_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.15sqmm_1x06_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD1.7mm +Soldered wire connection, for a single 0.25 mm² wire, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.25 mm² wire, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.25 mm² wire, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD2mm +Soldered wire connection, for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 2 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 2 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 3 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 3 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 4 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 4 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 5 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 5 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 6 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 6 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD2.3mm +Soldered wire connection, for a single 0.75 mm² wire, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.75 mm² wire, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.75 mm² wire, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD3.5mm +Soldered wire connection, for a single 0.75 mm² wire, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.75 mm² wire, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.75 mm² wire, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x02_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 2 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x03_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 3 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 3 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x04_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 4 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 4 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x05_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 5 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x06_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 6 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 6 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.127sqmm_1x01_D0.48mm_OD1mm +Soldered wire connection, for a single 0.127 mm² wire, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.127sqmm_1x01_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.127 mm² wire, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.127sqmm_1x01_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.127 mm² wire, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.127sqmm_1x02_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 2 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.127sqmm_1x02_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.127sqmm_1x02_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.127sqmm_1x03_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 3 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.127sqmm_1x03_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.127sqmm_1x03_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.127sqmm_1x04_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 4 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.127sqmm_1x04_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.127sqmm_1x04_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.127sqmm_1x05_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 5 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.127sqmm_1x05_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.127sqmm_1x05_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.127sqmm_1x06_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 6 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.127sqmm_1x06_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.127sqmm_1x06_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3.9mm +Soldered wire connection, for a single 1.5 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for a single 1.5 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1.5 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3mm +Soldered wire connection, for a single 1.5 mm² wire, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for a single 1.5 mm² wire, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1.5 mm² wire, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x02_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 2 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 2 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x03_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 3 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 3 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x04_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 4 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 4 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x05_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 5 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 5 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x06_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 6 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 6 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD2.7mm +Soldered wire connection, for a single 1 mm² wire, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for a single 1 mm² wire, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1 mm² wire, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD3.9mm +Soldered wire connection, for a single 1 mm² wire, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for a single 1 mm² wire, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1 mm² wire, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x02_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 2 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 2 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x03_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 3 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 3 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x04_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 4 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 4 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x05_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 5 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 5 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x06_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 6 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 6 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD3.6mm +Soldered wire connection, for a single 2.5 mm² wire, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for a single 2.5 mm² wire, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 2.5 mm² wire, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD4.4mm +Soldered wire connection, for a single 2.5 mm² wire, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for a single 2.5 mm² wire, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 2.5 mm² wire, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x02_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 2 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 2 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x03_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 3 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 3 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x04_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 4 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 4 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x05_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 5 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 5 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x06_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 6 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 6 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2sqmm_1x01_D2mm_OD3.9mm +Soldered wire connection, for a single 2 mm² wire, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +1 +1 +Connector_Wire +SolderWire-2sqmm_1x01_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for a single 2 mm² wire, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2sqmm_1x01_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 2 mm² wire, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2sqmm_1x02_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 2 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +2 +2 +Connector_Wire +SolderWire-2sqmm_1x02_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2sqmm_1x02_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2sqmm_1x03_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 3 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +3 +3 +Connector_Wire +SolderWire-2sqmm_1x03_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2sqmm_1x03_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2sqmm_1x04_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 4 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +4 +4 +Connector_Wire +SolderWire-2sqmm_1x04_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2sqmm_1x04_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2sqmm_1x05_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 5 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +5 +5 +Connector_Wire +SolderWire-2sqmm_1x05_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2sqmm_1x05_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2sqmm_1x06_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 6 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +6 +6 +Connector_Wire +SolderWire-2sqmm_1x06_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2sqmm_1x06_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWirePad_1x01_SMD_1x2mm +Wire Pad, Square, SMD Pad, 5mm x 10mm, +MesurementPoint Square SMDPad 5mmx10mm +0 +1 +1 +Connector_Wire +SolderWirePad_1x01_SMD_5x10mm +Wire Pad, Square, SMD Pad, 5mm x 10mm, +MesurementPoint Square SMDPad 5mmx10mm +0 +1 +1 +Connector_Wuerth +Wuerth_WR-WTB_64800211622_1x02_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800211622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +2 +2 +Connector_Wuerth +Wuerth_WR-WTB_64800311622_1x03_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800311622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +3 +3 +Connector_Wuerth +Wuerth_WR-WTB_64800411622_1x04_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800411622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +4 +4 +Connector_Wuerth +Wuerth_WR-WTB_64800511622_1x05_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800511622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +5 +5 +Connector_Wuerth +Wuerth_WR-WTB_64800611622_1x06_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800611622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +6 +6 +Connector_Wuerth +Wuerth_WR-WTB_64800711622_1x07_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800711622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +7 +7 +Connector_Wuerth +Wuerth_WR-WTB_64800811622_1x08_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800811622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +8 +8 +Connector_Wuerth +Wuerth_WR-WTB_64800911622_1x09_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800911622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +9 +9 +Connector_Wuerth +Wuerth_WR-WTB_64801011622_1x10_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64801011622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +10 +10 +Converter_ACDC +Converter_ACDC_CUI_PBO-3-Sxx_THT_Vertical +ACDC-Converter, 3W, CUI PBO-3, THT https://www.cui.com/product/resource/pbo-3.pdf +Converter AC-DC THT Vertical +0 +6 +6 +Converter_ACDC +Converter_ACDC_Hahn_HS-400xx_THT +ACDC-Converter, 3W, Hahn-HS-400xx, THT https://www.schukat.com/schukat/schukat_cms_de.nsf/index/FrameView?OpenDocument&art=HS40009&wg=M7942 +Hahn ACDC-Converter THT +0 +4 +4 +Converter_ACDC +Converter_ACDC_HiLink_HLK-PMxx +ACDC-Converter, 3W, HiLink, HLK-PMxx, THT, http://www.hlktech.net/product_detail.php?ProId=54 +ACDC-Converter 3W THT HiLink board mount module +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-02-xx_SMD +ACDC-Converter, 3W, Meanwell, IRM-02, SMD, https://www.meanwell.com/Upload/PDF/IRM-02/IRM-02-SPEC.PDF +ACDC-Converter 3W +0 +14 +14 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-02-xx_THT +ACDC-Converter, 2W, Meanwell, IRM-02, THT, https://www.meanwell.co.uk/media/productPDF/IRM-02-spec.pdf +ACDC-Converter 2W THT +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-03-xx_SMD +ACDC-Converter, 3W, Meanwell, IRM-03, SMD, http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-03 +ACDC-Converter 3W +0 +14 +14 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-03-xx_THT +ACDC-Converter, 3W, Meanwell, IRM-03, THT, https://www.meanwell.com/Upload/PDF/IRM-03/IRM-03-SPEC.PDF +ACDC-Converter 3W THT +0 +5 +5 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-05-xx_THT +http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-05 +ACDC-Converter 5W Meanwell IRM-05 +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-10-xx_THT +http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-10 +ACDC-Converter 10W Meanwell IRM-10 +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-20-xx_THT +ACDC-Converter, 20W, Meanwell, IRM-20, THT http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-20 +ACDC-Converter 20W Meanwell IRM-20 +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-60-xx_THT +ACDC-Converter, 50-60W, Meanwell, IRM-60, THT https://www.meanwellusa.com/productPdf.aspx?i=687 +switching power supply +0 +4 +4 +Converter_ACDC +Converter_ACDC_RECOM_RAC01-xxSGB_THT +https://www.recom-power.com/pdf/Powerline-AC-DC/RAC01-GB.pdf +recom power ac dc rac01xxgb rac01-05sgb rac01-12sgb +0 +4 +4 +Converter_ACDC +Converter_ACDC_RECOM_RAC04-xxSGx_THT +https://www.recom-power.com/pdf/Powerline-AC-DC/RAC04-GA.pdf +recom power ac dc +0 +5 +5 +Converter_ACDC +Converter_ACDC_RECOM_RAC05-xxSK_THT +https://www.recom-power.com/pdf/Powerline-AC-DC/RAC05-K.pdf +recom power ac dc +0 +5 +5 +Converter_ACDC +Converter_ACDC_TRACO_TMG-15_THT +ACDC-Converter, TRACO, TMG Series 15 https://www.tracopower.com/products/tmg.pdf +ACDC-Converter TRACO TMG Series 15 +0 +4 +4 +Converter_ACDC +Converter_ACDC_TRACO_TMLM-04_THT +ACDC-Converter, TRACO, TMLM Series 04 https://www.tracopower.com/products/tmlm.pdf +ACDC-Converter TRACO TMLM Series 04 +0 +7 +7 +Converter_ACDC +Converter_ACDC_TRACO_TMLM-05_THT +ACDC-Converter, TRACO TMLM 05,https://www.tracopower.com/products/tmlm.pdf +ACDC-Converter TRACO TMLM 05 +0 +4 +4 +Converter_ACDC +Converter_ACDC_TRACO_TMLM-10-20_THT +ACDC-Converter, TRACO TMLM 10, TRACO TMLM 20, https://www.tracopower.com/products/tmlm.pdf +ACDC-Converter TRACO TMLM 10 and TMLM 20 +0 +4 +4 +Converter_ACDC +Converter_ACDC_Vigortronix_VTX-214-010-xxx_THT +Vigortronix VTX-214-010-xxx serie of ACDC converter, http://www.vigortronix.com/10WattACDCPCBPowerModule.aspx +Vigortronix VTX-214-010-xxx serie of ACDC converter +0 +4 +4 +Converter_ACDC +Converter_ACDC_Vigortronix_VTX-214-015-1xx_THT +Vigortronix VTX-214-010-xxx serie of ACDC converter, http://www.vigortronix.com/10WattACDCPCBPowerModule.aspx +Vigortronix VTX-214-010-xxx serie of ACDC converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_Artesyn_ATA_SMD +DCDC-Converter, Artesyn, ATA Series, 3W Single and Dual Output, 1500VDC Isolation, 24.0x13.7x8.0mm https://www.artesyn.com/power/assets/ata_series_ds_01apr2015_79c25814fd.pdf https://www.artesyn.com/power/assets/trn_dc-dc_ata_3w_series_releas1430412818_techref.pdf +DCDC SMD +0 +7 +7 +Converter_DCDC +Converter_DCDC_Bothhand_CFUDxxxx_THT +DCDC-Converter, BOTHHAND, Type CFxxxx-Serie, (Very dodgy url but was the only at hand), +DCDC-Converter BOTHHAND Type CFxxxx-Serie +0 +10 +10 +Converter_DCDC +Converter_DCDC_Bothhand_CFUSxxxxEH_THT +DCDC-Converter, BOTHHAND, Type CFxxxx-Serie, (Very dodgy url but was the only at hand), +DCDC-Converter BOTHHAND Type CFxxxx-Serie +0 +9 +9 +Converter_DCDC +Converter_DCDC_Bothhand_CFUSxxxx_THT +DCDC-Converter, BOTHHAND, Type CFxxxx-Serie, (Very dodgy url but was the only at hand), +DCDC-Converter BOTHHAND Type CFxxxx-Serie +0 +8 +8 +Converter_DCDC +Converter_DCDC_Cincon_EC5BExx_Dual_THT +DCDC-Converter, CINCON, EC5BExx, 18-36VDC to Dual output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/B%20CASE/SPEC-EC5BE-V24.pdf +DCDC-Converter CINCON EC5BExx 18-36VDC to Dual output +0 +6 +6 +Converter_DCDC +Converter_DCDC_Cincon_EC5BExx_Single_THT +DCDC-Converter, CINCON, EC5BExx, 18-36VDC to dual output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/B%20CASE/SPEC-EC5BE-V24.pdf +DCDC-Converter CINCON EC5BExx 18-36VDC to dual output +0 +4 +4 +Converter_DCDC +Converter_DCDC_Cincon_EC6Cxx_Dual-Triple_THT +DCDC-Converter, CINCON, EC6Cxx, dual or tripple output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/C%20CASE/SPEC-EC6C-V12.pdf +DCDC-Converter CINCON EC6Cxx dual or tripple output +0 +7 +7 +Converter_DCDC +Converter_DCDC_Cincon_EC6Cxx_Single_THT +DCDC-Converter, CINCON, EC6Cxx, single output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/C%20CASE/SPEC-EC6C-V12.pdf +DCDC-Converter CINCON EC6Cxx single output +0 +6 +6 +Converter_DCDC +Converter_DCDC_Cyntec_MUN12AD01-SH +http://www.cyntec.com/upfile/products/download/Cyntec%20MUN12AD01-SH_Datasheet.pdf +Power Module uPOL MUN12AD01 +0 +13 +9 +Converter_DCDC +Converter_DCDC_Cyntec_MUN12AD03-SH +http://www.cyntec.com/upfile/products/download/Cyntec%20MUN12AD03-SH_Datasheet.pdf +Power Module uPOL MUN12AD03 +0 +19 +11 +Converter_DCDC +Converter_DCDC_MeanWell_NID30_THT +Meanwell DCDC non-isolated converter SIP module, http://www.meanwell.com/webapp/product/search.aspx?prod=nid30 +DCDC non-isolated converter +0 +11 +11 +Converter_DCDC +Converter_DCDC_MeanWell_NID60_THT +MeanWell NID60, http://www.meanwell.com/Upload/PDF/NID60/NID60-SPEC.PDF +MeanWell NID60 +0 +11 +11 +Converter_DCDC +Converter_DCDC_Murata_MEE1SxxxxSC_THT +https://power.murata.com/pub/data/power/ncl/kdc_mee1.pdf +murata dc-dc transformer +0 +4 +4 +Converter_DCDC +Converter_DCDC_Murata_MEE3SxxxxSC_THT +https://power.murata.com/pub/data/power/ncl/kdc_mee3.pdf +murata dc-dc transformer +0 +4 +4 +Converter_DCDC +Converter_DCDC_Murata_MGJ2DxxxxxxSC_THT +Murata MGJ2DxxxxxxSC, 19.5x9.8x12.5mm, 5.2kVDC Isolated, 2W, SIP package style, https://power.murata.com/data/power/ncl/kdc_mgj2.pdf +Murata MGJ2DxxxxxxSC +0 +5 +5 +Converter_DCDC +Converter_DCDC_Murata_MGJ3 +Murata MGJ3, 5.2kVDC Isolated 3W Gate Drive, 15V/5V/5V Configurable, 22.61x23.11x14.19mm, https://power.murata.com/datasheet?/data/power/ncl/kdc_mgj3.pdf +DCDC SMD +0 +7 +7 +Converter_DCDC +Converter_DCDC_Murata_NCS1SxxxxSC_THT +Murata NCS1SxxxxSC https://power.murata.com/data/power/ncl/kdc_ncs1.pdf (Script generated with StandardBox.py) (Murata NCS1SxxxxSC https://power.murata.com/data/power/ncl/kdc_ncs1.pdf) +Murata NCS1SxxxxSC +0 +5 +5 +Converter_DCDC +Converter_DCDC_RECOM_R-78B-2.0_THT +DCDC-Converter, RECOM, RECOM_R-78B-2.0, SIP-3, pitch 2.54mm, package size 11.5x8.5x17.5mm^3, https://www.recom-power.com/pdf/Innoline/R-78Bxx-2.0.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78E-0.5_THT +DCDC-Converter, RECOM, RECOM_R-78E-0.5, SIP-3, pitch 2.54mm, package size 11.6x8.5x10.4mm^3, https://www.recom-power.com/pdf/Innoline/R-78Exx-0.5.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78HB-0.5L_THT +DCDC-Converter, RECOM, RECOM_R-78HB-0.5L, SIP-3, Horizontally Mounted, pitch 2.54mm, package size 11.5x8.5x17.5mm^3, https://www.recom-power.com/pdf/Innoline/R-78HBxx-0.5_L.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78HB-0.5_THT +DCDC-Converter, RECOM, RECOM_R-78HB-0.5, SIP-3, pitch 2.54mm, package size 11.5x8.5x17.5mm^3, https://www.recom-power.com/pdf/Innoline/R-78HBxx-0.5_L.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78S-0.1_THT +DCDC-Converter, RECOM, RECOM_R-78S-0.1, SIP-4, pitch 2.54mm, package size 11.6x8.5x10.4mm^3, https://www.recom-power.com/pdf/Innoline/R-78Sxx-0.1.pdf +dc-dc recom buck sip-4 pitch 2.54mm +0 +4 +4 +Converter_DCDC +Converter_DCDC_RECOM_R5xxxDA_THT +DCDC-Converter, RECOM, RECOM_R5xxxDA, SIP-12, Horizontally Mounted, pitch 2.54mm, package size 32.2x9.1x15mm^3, https://www.recom-power.com/pdf/Innoline/R-5xxxPA_DA.pdf +dc-dc recom buck sip-12 pitch 2.54mm +0 +12 +12 +Converter_DCDC +Converter_DCDC_RECOM_R5xxxPA_THT +DCDC-Converter, RECOM, RECOM_R5xxxPA, SIP-12, pitch 2.54mm, package size 32.2x9.1x15mm^3, https://www.recom-power.com/pdf/Innoline/R-5xxxPA_DA.pdf +dc-dc recom buck sip-12 pitch 2.54mm +0 +12 +12 +Converter_DCDC +Converter_DCDC_RECOM_RPA60-xxxxSFW +RPA60-FW 60W Isolated DC to DC Converters +DCDC Regulator Single +0 +6 +6 +Converter_DCDC +Converter_DCDC_RECOM_RPMx.x-x.0 +https://www.recom-power.com/pdf/Innoline/RPM-6.0.pdf +dc-dc recom buck lga-25 pitch 2.29mm +0 +25 +25 +Converter_DCDC +Converter_DCDC_TRACO_TDN_5-xxxxWISM_SMD +Traco TDN 5WISM Series, 5W, SMD (https://assets.tracopower.com/20200225170127/TDN5WISM/documents/tdn5wism-datasheet.pdf#page=3) +dcdc traco 5w smd +0 +6 +6 +Converter_DCDC +Converter_DCDC_TRACO_TEN10-xxxx_Dual_THT +DCDC-Converter, TRACO, TEN10-xxxx, single output, https://assets.tracopower.com/20171102100522/TEN10/documents/ten10-datasheet.pdf +DCDC-Converter TRACO TEN10-xxxx single output +0 +5 +5 +Converter_DCDC +Converter_DCDC_TRACO_TEN10-xxxx_Single_THT +DCDC-Converter, TRACO, TEN10-xxxx, single output, https://assets.tracopower.com/20171102100522/TEN10/documents/ten10-datasheet.pdf +DCDC-Converter TRACO TEN10-xxxx single output +0 +4 +4 +Converter_DCDC +Converter_DCDC_TRACO_TEN10-xxxx_THT +DCDC-Converter, TRACO, TEN10-xxxx, https://assets.tracopower.com/20171102100522/TEN10/documents/ten10-datasheet.pdf +DCDC-Converter TRACO TEN10-xxxx +0 +4 +4 +Converter_DCDC +Converter_DCDC_TRACO_TEN20-xxxx-N4_THT +DCDC-Converter TRACO TEN20 Generic, https://assets.tracopower.com/20171102100522/TEN20/documents/ten20-datasheet.pdf +DCDC-Converter TRACO TEN20 Generic +0 +5 +5 +Converter_DCDC +Converter_DCDC_TRACO_TEN20-xxxx_THT +DCDC-Converter TRACO TEN20 Generic, https://assets.tracopower.com/20171102100522/TEN20/documents/ten20-datasheet.pdf +DCDC-Converter TRACO TEN20 Generic +0 +6 +6 +Converter_DCDC +Converter_DCDC_TRACO_THD_15-xxxxWIN_THT +Traco THD 15WIN, 15W, THT (https://www.tracopower.com/products/thd15win.pdf#page=3) +traco dcdc tht 15w +0 +9 +9 +Converter_DCDC +Converter_DCDC_TRACO_TMR-1-xxxx_Dual_THT +DCDC-Converter, TRACO, TMR 1-xxxx, Dual output, Rev. March 21.2016 +DCDC-Converter TRACO TMR1-xxxx Dual_output +0 +5 +5 +Converter_DCDC +Converter_DCDC_TRACO_TMR-1-xxxx_Single_THT +DCDC-Converter, TRACO, TMR 1-xxxx, Single output, Rev. March 21.2016 +DCDC-Converter TRACO TMR1-xxxx Single_output +0 +4 +4 +Converter_DCDC +Converter_DCDC_TRACO_TMR-1SM_SMD +http://assets.tracopower.com/TMR1SM/documents/tmr1sm-datasheet.pdf +DCDC SMD TRACO TMR-1SM +0 +7 +7 +Converter_DCDC +Converter_DCDC_TRACO_TMR-2xxxxWI_THT +https://www.tracopower.com/products/tmr2wi.pdf +DCDC-Converter TRACO TMRxxxxWI Single/Dual_output +0 +7 +7 +Converter_DCDC +Converter_DCDC_TRACO_TMR-xxxx_THT +DCDC-Converter, TRACO, TMR xxxx, Single/Dual output, http://www.datasheetlib.com/datasheet/135136/tmr-2-2410e_traco-power.html?page=3#datasheet +DCDC-Converter TRACO TMRxxxx Single/Dual_output +0 +7 +7 +Converter_DCDC +Converter_DCDC_TRACO_TSR-1_THT +DCDC-Converter, TRACO, TSR 1-xxxx +DCDC-Converter TRACO TSR-1 +0 +3 +3 +Converter_DCDC +Converter_DCDC_XP_POWER-IA48xxD_THT +XP_POWER IA48xxD, DIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IA48xxD DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IA48xxS_THT +XP_POWER IA48xxS, SIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IA48xxS SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-IAxxxxD_THT +XP_POWER IAxxxxD, DIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IAxxxxD DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IAxxxxS_THT +XP_POWER IAxxxxS, SIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IAxxxxS SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxDH_THT +XP_POWER IHxxxxDH, DIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxDH DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxD_THT +XP_POWER IHxxxxD, DIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxD DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxSH_THT +XP_POWER IHxxxxSH, SIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxSH SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxS_THT +XP_POWER IHxxxxS, SIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxS SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-ISU02_SMD +DCDC-Converter, XP POWER, ISU02 Series, 2W Single and Dual Output, 1500VDC Isolation, 19.0x17.0x8.7mm https://www.xppower.com/Portals/0/pdfs/SF_ISU02.pdf +DCDC SMD XP POWER ISU02 +0 +7 +7 +Converter_DCDC +Converter_DCDC_XP_POWER-ITQxxxxS-H_THT +XP_POWER ITQxxxxS-H, SIP, (https://www.xppower.com/pdfs/SF_ITQ.pdf), generated with kicad-footprint-generator +XP_POWER ITQxxxxS-H SIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-ITXxxxxSA_THT +XP_POWER ITXxxxxSA, SIP, (https://www.xppower.com/pdfs/SF_ITX.pdf), generated with kicad-footprint-generator +XP_POWER ITXxxxxSA SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-ITxxxxxS_THT +XP_POWER ITxxxxxS, SIP, (https://www.xppower.com/portals/0/pdfs/SF_ITX.pdf https://www.xppower.com/portals/0/pdfs/SF_ITQ.pdf), generated with kicad-footprint-generator +XP_POWER ITxxxxxS SIP DCDC-Converter +0 +7 +7 +Converter_DCDC +Converter_DCDC_XP_POWER_JTDxxxxxxx_THT +XP Power JTD Series DC-DC Converter +DCDC Isolated +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER_JTExxxxDxx_THT +DCDC-Converter, XP POWER, Type JTE06 Series, Dual Output +DCDC-Converter XP_POWER JTE06 Dual +0 +8 +8 +Converter_DCDC +Converter_DCDC_muRata_CRE1xxxxxx3C_THT +Isolated 1W single output DC/DC, http://power.murata.com/data/power/ncl/kdc_cre1.pdf +Isolated 1W single output DC/DC +0 +4 +4 +Converter_DCDC +Converter_DCDC_muRata_CRE1xxxxxxDC_THT +Isloated DC-DC, http://power.murata.com/data/power/ncl/kdc_cre1.pdf +Isloated DC-DC +0 +4 +4 +Converter_DCDC +Converter_DCDC_muRata_CRE1xxxxxxSC_THT +http://power.murata.com/data/power/ncl/kdc_cre1.pdf +murata dc-dc transformer +0 +4 +4 +Converter_DCDC +Converter_DCDC_muRata_NMAxxxxDC_THT +Isolated 1W DCDC-Converter, http://power.murata.com/data/power/ncl/kdc_nma.pdf +Isolated 1W DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_muRata_NMAxxxxSC_THT +muRata NMAxxxxSC footprint based on SIP7, http://power.murata.com/data/power/ncl/kdc_nma.pdf +muRata NMAxxxxSC DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_muRata_NXExSxxxxMC_SMD +Isolated 1W or 2W Single Output SM DC/DC Converters http://power.murata.com/data/power/ncl/kdc_nxe1.pdf http://power.murata.com/data/power/ncl/kdc_nxe2.pdf +Isolated 1W or 2W Single Output SM DC/DC Converters +0 +5 +5 +Converter_DCDC +Converter_DCDC_muRata_OKI-78SR_Horizontal +https://power.murata.com/data/power/oki-78sr.pdf +78sr3.3 78sr5 78sr9 78sr12 78srXX +0 +3 +3 +Converter_DCDC +Converter_DCDC_muRata_OKI-78SR_Vertical +https://power.murata.com/data/power/oki-78sr.pdf +78sr3.3 78sr5 78sr9 78sr12 78srXX +0 +3 +3 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Horizontal +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +2 +2 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Horizontal_1EP_style1 +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +3 +3 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Horizontal_1EP_style2 +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +5 +3 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Vertical +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +2 +2 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Horizontal +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +2 +2 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Horizontal_1EP_style1 +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +3 +3 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Horizontal_1EP_style2 +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +5 +3 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Vertical +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +2 +2 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Horizontal +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +2 +2 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Horizontal_1EP_style1 +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +3 +3 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Horizontal_1EP_style2 +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +5 +3 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Vertical +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +2 +2 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Horizontal +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +2 +2 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Horizontal_1EP_style1 +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +3 +3 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Horizontal_1EP_style2 +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +5 +3 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Vertical +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +2 +2 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Horizontal +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +2 +2 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Horizontal_1EP_style1 +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +3 +3 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Horizontal_1EP_style2 +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +5 +3 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Vertical +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +2 +2 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Horizontal +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +2 +2 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Horizontal_1EP_style1 +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +3 +3 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Horizontal_1EP_style2 +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +5 +3 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Vertical +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +2 +2 +Crystal +Crystal_HC18-U_Horizontal +Crystal THT HC-18/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC18-U_Horizontal_1EP_style1 +Crystal THT HC-18/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC18-U_Horizontal_1EP_style2 +Crystal THT HC-18/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC18-U_Vertical +Crystal THT HC-18/U, http://5hertz.com/pdfs/04404_D.pdf +THT crystalHC-18/U +0 +2 +2 +Crystal +Crystal_HC33-U_Horizontal +Crystal THT HC-33/U http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC33-U_Horizontal_1EP_style1 +Crystal THT HC-33/U http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC33-U_Horizontal_1EP_style2 +Crystal THT HC-33/U http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC33-U_Vertical +Crystal THT HC-33/U, http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystalHC-33/U +0 +2 +2 +Crystal +Crystal_HC35-U +Crystal, Quarz, HC35/U, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/TO71xx.pdf +Crystal Quarz HC35/U +0 +3 +3 +Crystal +Crystal_HC49-4H_Vertical +Crystal THT HC-49-4H http://5hertz.com/pdfs/04404_D.pdf +THT crystalHC-49-4H +0 +2 +2 +Crystal +Crystal_HC49-U-3Pin_Vertical +Crystal THT HC-49/U, 3pin-version, http://www.raltron.com/products/pdfspecs/crystal_hc_49_45_51.pdf +THT crystalHC-49/U +0 +3 +3 +Crystal +Crystal_HC49-U_Horizontal +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC49-U_Horizontal_1EP_style1 +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC49-U_Horizontal_1EP_style2 +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC49-U_Vertical +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystalHC-49/U +0 +2 +2 +Crystal +Crystal_HC50_Horizontal +Crystal THT HC-50 http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC50_Horizontal_1EP_style1 +Crystal THT HC-50 http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC50_Horizontal_1EP_style2 +Crystal THT HC-50 http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC50_Vertical +Crystal THT HC-50, http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystalHC-50 +0 +2 +2 +Crystal +Crystal_HC51-U_Vertical +Crystal THT HC-51/U, http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystalHC-51/U +0 +2 +2 +Crystal +Crystal_HC51_Horizontal +Crystal THT HC-51 http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC51_Horizontal_1EP_style1 +Crystal THT HC-51 http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC51_Horizontal_1EP_style2 +Crystal THT HC-51 http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-6mm_Horizontal +Crystal THT HC-51/6mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC52-6mm_Horizontal_1EP_style1 +Crystal THT HC-51/6mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC52-6mm_Horizontal_1EP_style2 +Crystal THT HC-51/6mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-6mm_Vertical +Crystal THT HC-52/6mm, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystalHC-49/U +0 +2 +2 +Crystal +Crystal_HC52-8mm_Horizontal +Crystal THT HC-51/8mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC52-8mm_Horizontal_1EP_style1 +Crystal THT HC-51/8mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC52-8mm_Horizontal_1EP_style2 +Crystal THT HC-51/8mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-8mm_Vertical +Crystal THT HC-52/8mm, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystalHC-49/U +0 +2 +2 +Crystal +Crystal_HC52-U-3Pin_Vertical +Crystal THT HC-52/U, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystalHC-52/U +0 +3 +3 +Crystal +Crystal_HC52-U_Horizontal +Crystal THT HC-51/U http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC52-U_Horizontal_1EP_style1 +Crystal THT HC-51/U http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC52-U_Horizontal_1EP_style2 +Crystal THT HC-51/U http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-U_Vertical +Crystal THT HC-52/U, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal HC-52/U +0 +2 +2 +Crystal +Crystal_Round_D1.0mm_Vertical +Crystal THT DS10 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +2 +2 +Crystal +Crystal_Round_D1.5mm_Vertical +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +2 +2 +Crystal +Crystal_Round_D2.0mm_Vertical +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +2 +2 +Crystal +Crystal_Round_D3.0mm_Vertical +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +2 +2 +Crystal +Crystal_SMD_0603-2Pin_6.0x3.5mm +SMD Crystal SERIES SMD0603/2 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-2.pdf, 6.0x3.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_0603-2Pin_6.0x3.5mm_HandSoldering +SMD Crystal SERIES SMD0603/2 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-2.pdf, hand-soldering, 6.0x3.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_0603-4Pin_6.0x3.5mm +SMD Crystal SERIES SMD0603/4 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-4.pdf, 6.0x3.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_0603-4Pin_6.0x3.5mm_HandSoldering +SMD Crystal SERIES SMD0603/4 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-4.pdf, hand-soldering, 6.0x3.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_2012-2Pin_2.0x1.2mm +SMD Crystal 2012/2 http://txccrystal.com/images/pdf/9ht11.pdf, 2.0x1.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_2012-2Pin_2.0x1.2mm_HandSoldering +SMD Crystal 2012/2 http://txccrystal.com/images/pdf/9ht11.pdf, hand-soldering, 2.0x1.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_2016-4Pin_2.0x1.6mm +SMD Crystal SERIES SMD2016/4 http://www.q-crystal.com/upload/5/2015552223166229.pdf, 2.0x1.6mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_2520-4Pin_2.5x2.0mm +SMD Crystal SERIES SMD2520/4 http://www.newxtal.com/UploadFiles/Images/2012-11-12-09-29-09-776.pdf, 2.5x2.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_3215-2Pin_3.2x1.5mm +SMD Crystal FC-135 https://support.epson.biz/td/api/doc_check.php?dl=brief_FC-135R_en.pdf +SMD SMT Crystal +0 +2 +2 +Crystal +Crystal_SMD_3225-4Pin_3.2x2.5mm +SMD Crystal SERIES SMD3225/4 http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_3225-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal SERIES SMD3225/4 http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_5032-2Pin_5.0x3.2mm +SMD Crystal SERIES SMD2520/2 http://www.icbase.com/File/PDF/HKC/HKC00061008.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_5032-2Pin_5.0x3.2mm_HandSoldering +SMD Crystal SERIES SMD2520/2 http://www.icbase.com/File/PDF/HKC/HKC00061008.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_5032-4Pin_5.0x3.2mm +SMD Crystal SERIES SMD2520/4 http://www.icbase.com/File/PDF/HKC/HKC00061008.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_7050-2Pin_7.0x5.0mm +SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_7050-2Pin_7.0x5.0mm_HandSoldering +SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_7050-4Pin_7.0x5.0mm +SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM3-2Pin_5.0x3.2mm +Abracon Miniature Ceramic Smd Crystal ABM3 http://www.abracon.com/Resonators/abm3.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_Abracon_ABM3-2Pin_5.0x3.2mm_HandSoldering +Abracon Miniature Ceramic Smd Crystal ABM3 http://www.abracon.com/Resonators/abm3.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_Abracon_ABM3B-4Pin_5.0x3.2mm +Abracon Miniature Ceramic Smd Crystal ABM3B http://www.abracon.com/Resonators/abm3b.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM3C-4Pin_5.0x3.2mm +Abracon Miniature Ceramic Smd Crystal ABM3C http://www.abracon.com/Resonators/abm3c.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM7-2Pin_6.0x3.5mm +SMD Crystal Abracon ABM7, https://abracon.com/Resonators/abm7.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_Abracon_ABM8G-4Pin_3.2x2.5mm +Abracon Miniature Ceramic Smd Crystal ABM8G http://www.abracon.com/Resonators/ABM8G.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM10-4Pin_2.5x2.0mm +Abracon Miniature Ceramic Smd Crystal ABM10 http://www.abracon.com/Resonators/ABM10.pdf +SMD SMT crystal Abracon ABM10 +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABS25-4Pin_8.0x3.8mm +Abracon Miniature Ceramic SMD Crystal ABS25 https://abracon.com/Resonators/abs25.pdf, 8.0x3.8mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_ECS_CSM3X-2Pin_7.6x4.1mm +http://www.ecsxtal.com/store/pdf/CSM-3X.pdf +Crystal CSM-3X +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_EQ161-2Pin_3.2x1.5mm +SMD Crystal EuroQuartz EQ161 series http://cdn-reichelt.de/documents/datenblatt/B400/PG32768C.pdf, 3.2x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_EQ161-2Pin_3.2x1.5mm_HandSoldering +SMD Crystal EuroQuartz EQ161 series http://cdn-reichelt.de/documents/datenblatt/B400/PG32768C.pdf, hand-soldering, 3.2x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_MJ-4Pin_5.0x3.2mm +SMD Crystal EuroQuartz MJ series http://cdn-reichelt.de/documents/datenblatt/B400/MJ.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MJ-4Pin_5.0x3.2mm_HandSoldering +SMD Crystal EuroQuartz MJ series http://cdn-reichelt.de/documents/datenblatt/B400/MJ.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MQ-4Pin_7.0x5.0mm +SMD Crystal EuroQuartz MQ series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MQ-4Pin_7.0x5.0mm_HandSoldering +SMD Crystal EuroQuartz MQ series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MQ2-2Pin_7.0x5.0mm +SMD Crystal EuroQuartz MQ2 series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_MQ2-2Pin_7.0x5.0mm_HandSoldering +SMD Crystal EuroQuartz MQ2 series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_MT-4Pin_3.2x2.5mm +SMD Crystal EuroQuartz MT series http://cdn-reichelt.de/documents/datenblatt/B400/MT.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MT-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal EuroQuartz MT series http://cdn-reichelt.de/documents/datenblatt/B400/MT.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_X22-4Pin_2.5x2.0mm +SMD Crystal EuroQuartz X22 series http://cdn-reichelt.de/documents/datenblatt/B400/DS_X22.pdf, 2.5x2.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_X22-4Pin_2.5x2.0mm_HandSoldering +SMD Crystal EuroQuartz X22 series http://cdn-reichelt.de/documents/datenblatt/B400/DS_X22.pdf, hand-soldering, 2.5x2.0mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_FOX_FE-2Pin_7.5x5.0mm +crystal Ceramic Resin Sealed SMD http://www.foxonline.com/pdfs/fe.pdf, 7.5x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_FOX_FE-2Pin_7.5x5.0mm_HandSoldering +crystal Ceramic Resin Sealed SMD http://www.foxonline.com/pdfs/fe.pdf, hand-soldering, 7.5x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_FOX_FQ7050-2Pin_7.0x5.0mm +FOX SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_FOX_FQ7050-2Pin_7.0x5.0mm_HandSoldering +FOX SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_FOX_FQ7050-4Pin_7.0x5.0mm +FOX SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_FrontierElectronics_FM206 +SMD Watch Crystal FrontierElectronics FM206 6.0mm length 1.9mm diameter http://www.chinafronter.com/wp-content/uploads/2013/12/FM206.pdf +['FM206'] +0 +3 +3 +Crystal +Crystal_SMD_G8-2Pin_3.2x1.5mm +SMD Crystal G8, 3.2x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_G8-2Pin_3.2x1.5mm_HandSoldering +SMD Crystal G8, hand-soldering, 3.2x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_HC49-SD +SMD Crystal HC-49-SD http://cdn-reichelt.de/documents/datenblatt/B400/xxx-HC49-SMD.pdf, 11.4x4.7mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_HC49-SD_HandSoldering +SMD Crystal HC-49-SD http://cdn-reichelt.de/documents/datenblatt/B400/xxx-HC49-SMD.pdf, hand-soldering, 11.4x4.7mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC1V-T1A-2Pin_8.0x3.7mm +SMD Crystal MicroCrystal CC1V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC1V-T1A.pdf, 8.0x3.7mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC1V-T1A-2Pin_8.0x3.7mm_HandSoldering +SMD Crystal MicroCrystal CC1V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC1V-T1A.pdf, hand-soldering, 8.0x3.7mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC4V-T1A-2Pin_5.0x1.9mm +SMD Crystal MicroCrystal CC4V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC4V-T1A.pdf, 5.0x1.9mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC4V-T1A-2Pin_5.0x1.9mm_HandSoldering +SMD Crystal MicroCrystal CC4V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC4V-T1A.pdf, hand-soldering, 5.0x1.9mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC5V-T1A-2Pin_4.1x1.5mm +SMD Crystal MicroCrystal CC5V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC5V-T1A.pdf, 4.1x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC5V-T1A-2Pin_4.1x1.5mm_HandSoldering +SMD Crystal MicroCrystal CC5V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC5V-T1A.pdf, hand-soldering, 4.1x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC7V-T1A-2Pin_3.2x1.5mm +SMD Crystal MicroCrystal CC7V-T1A/CM7V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC7V-T1A.pdf, 3.2x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC7V-T1A-2Pin_3.2x1.5mm_HandSoldering +SMD Crystal MicroCrystal CC7V-T1A/CM7V-T1A series http://www.microcrystal.com/images/_Product-Documentation/01_TF_ceramic_Packages/01_Datasheet/CC1V-T1A.pdf, hand-soldering, 3.2x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC8V-T1A-2Pin_2.0x1.2mm +SMD Crystal MicroCrystal CC8V-T1A/CM8V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC8V-T1A.pdf, 2.0x1.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC8V-T1A-2Pin_2.0x1.2mm_HandSoldering +SMD Crystal MicroCrystal CC8V-T1A/CM8V-T1A series http://www.microcrystal.com/images/_Product-Documentation/01_TF_ceramic_Packages/01_Datasheet/CC8V-T1A.pdf, hand-soldering, 2.0x1.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CM9V-T1A-2Pin_1.6x1.0mm +SMD Crystal MicroCrystal CM9V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CM9V-T1A.pdf, 1.6x1.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CM9V-T1A-2Pin_1.6x1.0mm_HandSoldering +SMD Crystal MicroCrystal CM9V-T1A series http://www.microcrystal.com/images/_Product-Documentation/01_TF_ceramic_Packages/01_Datasheet/CM9V-T1A.pdf, hand-soldering, 1.6x1.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_MS1V-T1K +SMD Watch Crystal MicroCrystal MS1V-T1K 6.1mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/MS1V-T1K.pdf +['MS1V-T1K'] +0 +3 +3 +Crystal +Crystal_SMD_MicroCrystal_MS3V-T1R +SMD Watch Crystal MicroCrystal MS3V-T1R 5.2mm length 1.4mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/MS3V-T1R.pdf +['MS3V-T1R'] +0 +3 +3 +Crystal +Crystal_SMD_Qantek_QC5CB-2Pin_5x3.2mm +SMD Crystal Qantek QC5CB, https://www.qantek.com/tl_files/products/crystals/QC5CB.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_FA238-4Pin_3.2x2.5mm +crystal Epson Toyocom FA-238 https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_FA238-4Pin_3.2x2.5mm_HandSoldering +crystal Epson Toyocom FA-238 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_FA238V-4Pin_3.2x2.5mm +crystal Epson Toyocom FA-238 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_FA238V-4Pin_3.2x2.5mm_HandSoldering +crystal Epson Toyocom FA-238 series http://www.mouser.com/ds/2/137/1721499-465440.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA406-4Pin_11.7x4.0mm +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, 11.7x4.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA406-4Pin_11.7x4.0mm_HandSoldering +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, hand-soldering, 11.7x4.0mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA505-2Pin_12.7x5.1mm +SMD Crystal Seiko Epson MC-505 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, 12.7x5.1mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MA505-2Pin_12.7x5.1mm_HandSoldering +SMD Crystal Seiko Epson MC-505 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, hand-soldering, 12.7x5.1mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MA506-4Pin_12.7x5.1mm +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, 12.7x5.1mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA506-4Pin_12.7x5.1mm_HandSoldering +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, hand-soldering, 12.7x5.1mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC146-4Pin_6.7x1.5mm +SMD Crystal Seiko Epson MC-146 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, 6.7x1.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC146-4Pin_6.7x1.5mm_HandSoldering +SMD Crystal Seiko Epson MC-146 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, hand-soldering, 6.7x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC156-4Pin_7.1x2.5mm +SMD Crystal Seiko Epson MC-156 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, 7.1x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC156-4Pin_7.1x2.5mm_HandSoldering +SMD Crystal Seiko Epson MC-156 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, hand-soldering, 7.1x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC306-4Pin_8.0x3.2mm +SMD Crystal Seiko Epson MC-306 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, 8.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC306-4Pin_8.0x3.2mm_HandSoldering +SMD Crystal Seiko Epson MC-306 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, hand-soldering, 8.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC405-2Pin_9.6x4.1mm +SMD Crystal Seiko Epson MC-405 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, 9.6x4.1mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MC405-2Pin_9.6x4.1mm_HandSoldering +SMD Crystal Seiko Epson MC-405 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, hand-soldering, 9.6x4.1mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MC406-4Pin_9.6x4.1mm +SMD Crystal Seiko Epson MC-406 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, 9.6x4.1mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC406-4Pin_9.6x4.1mm_HandSoldering +SMD Crystal Seiko Epson MC-406 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, hand-soldering, 9.6x4.1mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_TSX3225-4Pin_3.2x2.5mm +crystal Epson Toyocom TSX-3225 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_TSX3225-4Pin_3.2x2.5mm_HandSoldering +crystal Epson Toyocom TSX-3225 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_TXC_7A-2Pin_5x3.2mm +SMD Crystal TXC 7A http://txccrystal.com/images/pdf/7a.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_TXC_7M-4Pin_3.2x2.5mm +SMD Crystal TXC 7M http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_TXC_7M-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal TXC 7M http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_TXC_9HT11-2Pin_2.0x1.2mm +SMD Crystal TXC 9HT11 http://txccrystal.com/images/pdf/9ht11.pdf, 2.0x1.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_TXC_9HT11-2Pin_2.0x1.2mm_HandSoldering +SMD Crystal TXC 9HT11 http://txccrystal.com/images/pdf/9ht11.pdf, hand-soldering, 2.0x1.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_TXC_AX_8045-2Pin_8.0x4.5mm +http://www.txccrystal.com/images/pdf/ax-automotive.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Resonator-2Pin_W6.0mm_H3.0mm +Ceramic Resomator/Filter 6.0x3.0mm^2, length*width=6.0x3.0mm^2 package, package length=6.0mm, package width=3.0mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-2Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter 7.0x2.5mm^2, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-2Pin_W8.0mm_H3.5mm +Ceramic Resomator/Filter 8.0x3.5mm^2, length*width=8.0x3.5mm^2 package, package length=8.0mm, package width=3.5mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-2Pin_W10.0mm_H5.0mm +Ceramic Resomator/Filter 10.0x5.0 RedFrequency MG/MT/MX series, http://www.red-frequency.com/download/datenblatt/redfrequency-datenblatt-ir-zta.pdf, length*width=10.0x5.0mm^2 package, package length=10.0mm, package width=5.0mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-3Pin_W6.0mm_H3.0mm +Ceramic Resomator/Filter 6.0x3.0mm^2, length*width=6.0x3.0mm^2 package, package length=6.0mm, package width=3.0mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator-3Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter 7.0x2.5mm^2, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator-3Pin_W8.0mm_H3.5mm +Ceramic Resomator/Filter 8.0x3.5mm^2, length*width=8.0x3.5mm^2 package, package length=8.0mm, package width=3.5mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator-3Pin_W10.0mm_H5.0mm +Ceramic Resomator/Filter 10.0x5.0mm^2 RedFrequency MG/MT/MX series, http://www.red-frequency.com/download/datenblatt/redfrequency-datenblatt-ir-zta.pdf, length*width=10.0x5.0mm^2 package, package length=10.0mm, package width=5.0mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator_SMD-3Pin_7.2x3.0mm +SMD Resomator/Filter 7.2x3.0mm, Murata CSTCC8M00G53-R0; 8MHz resonator, SMD, Farnell (Element 14) #1170435, http://www.farnell.com/datasheets/19296.pdf?_ga=1.247244932.122297557.1475167906, 7.2x3.0mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD-3Pin_7.2x3.0mm_HandSoldering +SMD Resomator/Filter 7.2x3.0mm, Murata CSTCC8M00G53-R0; 8MHz resonator, SMD, Farnell (Element 14) #1170435, http://www.farnell.com/datasheets/19296.pdf?_ga=1.247244932.122297557.1475167906, hand-soldering, 7.2x3.0mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_SMD_muRata_CDSCB-2Pin_4.5x2.0mm +SMD Resomator/Filter Murata CDSCB, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 4.5x2.0mm^2 package +SMD SMT ceramic resonator filter filter +0 +2 +2 +Crystal +Resonator_SMD_muRata_CDSCB-2Pin_4.5x2.0mm_HandSoldering +SMD Resomator/Filter Murata CDSCB, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 4.5x2.0mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +2 +2 +Crystal +Resonator_SMD_muRata_CSTxExxV-3Pin_3.0x1.1mm +SMD Resomator/Filter Murata CSTCE, https://www.murata.com/en-eu/products/productdata/8801162264606/SPEC-CSTNE16M0VH3C000R0.pdf +SMD SMT ceramic resonator filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_CSTxExxV-3Pin_3.0x1.1mm_HandSoldering +SMD Resomator/Filter Murata CSTCE, https://www.murata.com/en-eu/products/productdata/8801162264606/SPEC-CSTNE16M0VH3C000R0.pdf +SMD SMT ceramic resonator filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFECV-3Pin_6.9x2.9mm +SMD Resomator/Filter Murata SFECV, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 6.9x2.9mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFECV-3Pin_6.9x2.9mm_HandSoldering +SMD Resomator/Filter Murata SFECV, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 6.9x2.9mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFSKA-3Pin_7.9x3.8mm +SMD Resomator/Filter Murata SFSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFSKA-3Pin_7.9x3.8mm_HandSoldering +SMD Resomator/Filter Murata SFSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_SMD_muRata_TPSKA-3Pin_7.9x3.8mm +SMD Resomator/Filter Murata TPSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_TPSKA-3Pin_7.9x3.8mm_HandSoldering +SMD Resomator/Filter Murata TPSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_muRata_CSTLSxxxG-3Pin_W8.0mm_H3.0mm +Ceramic Resomator/Filter Murata CSTLSxxxG, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/timingdevice/ceralock/p17e.ashx, length*width=8.0x3.0mm^2 package, package length=8.0mm, package width=3.0mm, 3 pins +THT ceramic resonator filter CSTLSxxxG +0 +3 +3 +Crystal +Resonator_muRata_CSTLSxxxX-3Pin_W5.5mm_H3.0mm +Ceramic Resomator/Filter Murata CSTLSxxxX, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/timingdevice/ceralock/p17e.ashx, length*width=5.5x3.0mm^2 package, package length=5.5mm, package width=3.0mm, 3 pins +THT ceramic resonator filter CSTLSxxxX +0 +3 +3 +Crystal +Resonator_muRata_DSN6-3Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter Murata DSN6, http://cdn-reichelt.de/documents/datenblatt/B400/DSN6NC51H.pdf, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 3 pins +THT ceramic resonator filter DSN6 +0 +3 +3 +Crystal +Resonator_muRata_DSS6-3Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter Murata DSS6, http://cdn-reichelt.de/documents/datenblatt/B400/DSN6NC51H.pdf, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 3 pins +THT ceramic resonator filter DSS6 +0 +3 +3 +Diode_SMD +D_0201_0603Metric +Diode SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +diode +0 +4 +2 +Diode_SMD +D_0201_0603Metric_Castellated +Diode SMD 0201 (0603 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +diode castellated +0 +4 +2 +Diode_SMD +D_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Diode SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +diode handsolder +0 +4 +2 +Diode_SMD +D_0402_1005Metric +Diode SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_0402_1005Metric_Castellated +Diode SMD 0402 (1005 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_0402_1005Metric_Pad0.77x0.64mm_HandSolder +Diode SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_0603_1608Metric +Diode SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_0603_1608Metric_Castellated +Diode SMD 0603 (1608 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_0603_1608Metric_Pad1.05x0.95mm_HandSolder +Diode SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_0805_2012Metric +Diode SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_0805_2012Metric_Castellated +Diode SMD 0805 (2012 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_0805_2012Metric_Pad1.15x1.40mm_HandSolder +Diode SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_01005_0402Metric +Diode SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +diode +0 +4 +2 +Diode_SMD +D_01005_0402Metric_Castellated +Diode SMD 01005 (0402 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +diode castellated +0 +4 +2 +Diode_SMD +D_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Diode SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +diode handsolder +0 +4 +2 +Diode_SMD +D_1206_3216Metric +Diode SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_1206_3216Metric_Castellated +Diode SMD 1206 (3216 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_1206_3216Metric_Pad1.42x1.75mm_HandSolder +Diode SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_1210_3225Metric +Diode SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_1210_3225Metric_Castellated +Diode SMD 1210 (3225 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_1210_3225Metric_Pad1.42x2.65mm_HandSolder +Diode SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_1812_4532Metric +Diode SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_1812_4532Metric_Castellated +Diode SMD 1812 (4532 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Diode SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2010_5025Metric +Diode SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2010_5025Metric_Castellated +Diode SMD 2010 (5025 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2010_5025Metric_Pad1.52x2.65mm_HandSolder +Diode SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2114_3652Metric +Diode SMD 2114 (3652 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2114_3652Metric_Castellated +Diode SMD 2114 (3652 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2114_3652Metric_Pad1.85x3.75mm_HandSolder +Diode SMD 2114 (3652 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2512_6332Metric +Diode SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2512_6332Metric_Castellated +Diode SMD 2512 (6332 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2512_6332Metric_Pad1.52x3.35mm_HandSolder +Diode SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2816_7142Metric +Diode SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2816_7142Metric_Castellated +Diode SMD 2816 (7142 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Diode SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_3220_8050Metric +Diode SMD 3220 (8050 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_3220_8050Metric_Castellated +Diode SMD 3220 (8050 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_3220_8050Metric_Pad2.65x5.15mm_HandSolder +Diode SMD 3220 (8050 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_MELF +Diode, MELF,, +Diode MELF +0 +2 +2 +Diode_SMD +D_MELF-RM10_Universal_Handsoldering +Diode, Universal, MELF, RM10, Handsoldering, SMD, Thruhole, +Diode Universal MELF RM10 Handsoldering SMD Thruhole +0 +2 +2 +Diode_SMD +D_MELF_Handsoldering +Diode MELF Handsoldering +Diode MELF Handsoldering +0 +2 +2 +Diode_SMD +D_MicroMELF +Diode, MicroMELF, Reflow Soldering, http://www.vishay.com/docs/85597/bzm55.pdf +MicroMELF Diode +0 +2 +2 +Diode_SMD +D_MicroMELF_Handsoldering +Diode, MicroMELF, Hand Soldering, http://www.vishay.com/docs/85597/bzm55.pdf +MicroMELF Diode +0 +2 +2 +Diode_SMD +D_MiniMELF +Diode Mini-MELF (SOD-80) +Diode Mini-MELF (SOD-80) +0 +2 +2 +Diode_SMD +D_MiniMELF_Handsoldering +Diode Mini-MELF (SOD-80) Handsoldering +Diode Mini-MELF (SOD-80) Handsoldering +0 +2 +2 +Diode_SMD +D_PowerDI-5 +PowerDI,Diode,Vishay,https://www.diodes.com/assets/Package-Files/PowerDI5.pdf +PowerDI diode vishay +0 +3 +2 +Diode_SMD +D_PowerDI-123 +http://www.diodes.com/_files/datasheets/ds30497.pdf +PowerDI diode vishay +0 +2 +2 +Diode_SMD +D_Powermite2_AK +Microsemi Powermite 2 SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5341) +PowerMite2 +0 +2 +2 +Diode_SMD +D_Powermite2_KA +Microsemi Powermite 2 SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5341) +PowerMite2 +0 +2 +2 +Diode_SMD +D_Powermite3 +Microsemi Powermite 3 SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5340) +PowerMite3 +0 +3 +3 +Diode_SMD +D_Powermite_AK +Microsemi Powermite SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5339, https://www.onsemi.com/pub/Collateral/457-04.PDF) +Powermite +0 +2 +2 +Diode_SMD +D_Powermite_KA +Microsemi Powermite SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5339, https://www.onsemi.com/pub/Collateral/457-04.PDF) +Powermite +0 +2 +2 +Diode_SMD +D_QFN_3.3x3.3mm_P0.65mm +QFN, diode, 3.3x3.3x1mm (https://www.wolfspeed.com/media/downloads/846/C3D1P7060Q.pdf) +diode qfn 3.3 +0 +3 +2 +Diode_SMD +D_SC-80 +JEITA SC-80 +SC-80 +0 +2 +2 +Diode_SMD +D_SC-80_HandSoldering +JEITA SC-80 +SC-80 +0 +2 +2 +Diode_SMD +D_SMA +Diode SMA (DO-214AC) +Diode SMA (DO-214AC) +0 +2 +2 +Diode_SMD +D_SMA-SMB_Universal_Handsoldering +Diode, Universal, SMA (DO-214AC) or SMB (DO-214AA), Handsoldering, +Diode Universal SMA (DO-214AC) SMB (DO-214AA) Handsoldering +0 +2 +2 +Diode_SMD +D_SMA_Handsoldering +Diode SMA (DO-214AC) Handsoldering +Diode SMA (DO-214AC) Handsoldering +0 +2 +2 +Diode_SMD +D_SMB +Diode SMB (DO-214AA) +Diode SMB (DO-214AA) +0 +2 +2 +Diode_SMD +D_SMB-SMC_Universal_Handsoldering +Diode, Universal, SMB(DO-214AA) or SMC (DO-214AB), Handsoldering, +Diode Universal SMB(DO-214AA) SMC (DO-214AB) Handsoldering +0 +2 +2 +Diode_SMD +D_SMB_Handsoldering +Diode SMB (DO-214AA) Handsoldering +Diode SMB (DO-214AA) Handsoldering +0 +2 +2 +Diode_SMD +D_SMB_Modified +Diode SMB (DO-214AA) Modified (http://www.littelfuse.com/~/media/electronics/datasheets/sidactors/littelfuse_sidactor_battrax_positive_negative_modified_do_214_datasheet.pdf.pdf) +Diode SMB (DO-214AA) +0 +3 +3 +Diode_SMD +D_SMC +Diode SMC (DO-214AB) +Diode SMC (DO-214AB) +0 +2 +2 +Diode_SMD +D_SMC-RM10_Universal_Handsoldering +Diode, Universal, SMC (DO-214AB), RM10, Handsoldering, SMD, Thruhole +Diode Universal SMC (DO-214AB) RM10 Handsoldering SMD Thruhole +0 +2 +2 +Diode_SMD +D_SMC_Handsoldering +Diode SMC (DO-214AB) Handsoldering +Diode SMC (DO-214AB) Handsoldering +0 +2 +2 +Diode_SMD +D_SMF +Diode SMF (DO-219AB), http://www.vishay.com/docs/95572/smf_do-219ab.pdf +Diode SMF (DO-214AB) +0 +2 +2 +Diode_SMD +D_SOD-110 +SOD-110 +SOD-110 +0 +2 +2 +Diode_SMD +D_SOD-123 +SOD-123 +SOD-123 +0 +2 +2 +Diode_SMD +D_SOD-123F +D_SOD-123F +D_SOD-123F +0 +2 +2 +Diode_SMD +D_SOD-128 +D_SOD-128 (CFP5 SlimSMAW), https://assets.nexperia.com/documents/outline-drawing/SOD128.pdf +D_SOD-128 +0 +2 +2 +Diode_SMD +D_SOD-323 +SOD-323 +SOD-323 +0 +2 +2 +Diode_SMD +D_SOD-323F +SOD-323F http://www.nxp.com/documents/outline_drawing/SOD323F.pdf +SOD-323F +0 +2 +2 +Diode_SMD +D_SOD-323_HandSoldering +SOD-323 +SOD-323 +0 +2 +2 +Diode_SMD +D_SOD-523 +http://www.diodes.com/datasheets/ap02001.pdf p.144 +Diode SOD523 +0 +2 +2 +Diode_SMD +D_SOD-923 +https://www.onsemi.com/pub/Collateral/ESD9B-D.PDF#page=4 +Diode SOD923 +0 +2 +2 +Diode_SMD +D_SOT-23_ANK +SOT-23, Single Diode +SOT-23 +0 +3 +2 +Diode_SMD +D_SOT-23_NKA +SOT-23, Single Diode +SOT-23 +0 +3 +2 +Diode_SMD +D_TUMD2 +ROHM - TUMD2 +TUMD2 +0 +2 +2 +Diode_SMD +Diode_Bridge_Bourns_CD-DF4xxS +8.1x10.5mm, 4A, single phase bridge rectifier, https://www.bourns.com/docs/Product-Datasheets/CD-DF4xxSL.pdf +Surface Mount Bridge Rectifier Diode +0 +4 +4 +Diode_SMD +Diode_Bridge_Diotec_ABS +SMD diode bridge ABS (Diotec), see https://diotec.com/tl_files/diotec/files/pdf/datasheets/abs2.pdf +ABS MBLS +0 +4 +4 +Diode_SMD +Diode_Bridge_Diotec_MicroDil_3.0x3.0x1.8mm +SMD package Diotec Diotec MicroDil, body 3.0x3.0x1.8mm (e.g. diode bridge), see https://diotec.com/tl_files/diotec/files/pdf/datasheets/mys40.pdf +Diotec MicroDil diode bridge +0 +4 +4 +Diode_SMD +Diode_Bridge_Diotec_SO-DIL-Slim +SMD diode bridge Diotec SO-DIL Slim, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/b40fs.pdf +DFS SO-DIL Slim +0 +4 +4 +Diode_SMD +Diode_Bridge_Vishay_DFS +SMD diode bridge DFS, see http://www.vishay.com/docs/88854/padlayouts.pdf +DFS +0 +4 +4 +Diode_SMD +Diode_Bridge_Vishay_DFSFlat +SMD diode bridge Low Profile DFS "Flat", see http://www.vishay.com/docs/88874/dfl15005.pdf +DFS +0 +4 +4 +Diode_SMD +Diode_Bridge_Vishay_MBLS +SMD diode bridge MBLS, see http://www.vishay.com/docs/89959/mbl104s.pdf http://www.vishay.com/docs/88854/padlayouts.pdf +DFS +0 +4 +4 +Diode_SMD +Littelfuse_PolyZen-LS +http://m.littelfuse.com/~/media/electronics/datasheets/polyzen_devices/littelfuse_polyzen_standard_polyzen_catalog_datasheet.pdf.pdf +Diode Polymer Protected Zener Diode Littelfuse LS +0 +3 +3 +Diode_THT +D_5KPW_P7.62mm_Vertical_AnodeUp +Diode, 5KPW series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9*8mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KPW series Axial Vertical pin pitch 7.62mm length 9mm diameter 8mm +0 +2 +2 +Diode_THT +D_5KPW_P7.62mm_Vertical_KathodeUp +Diode, 5KPW series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9*8mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KPW series Axial Vertical pin pitch 7.62mm length 9mm diameter 8mm +0 +2 +2 +Diode_THT +D_5KPW_P12.70mm_Horizontal +Diode, 5KPW series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9*8mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KPW series Axial Horizontal pin pitch 12.7mm length 9mm diameter 8mm +0 +2 +2 +Diode_THT +D_5KP_P7.62mm_Vertical_AnodeUp +Diode, 5KP series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Vertical pin pitch 7.62mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5KP_P7.62mm_Vertical_KathodeUp +Diode, 5KP series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Vertical pin pitch 7.62mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5KP_P10.16mm_Horizontal +Diode, 5KP series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Horizontal pin pitch 10.16mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5KP_P12.70mm_Horizontal +Diode, 5KP series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Horizontal pin pitch 12.7mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5W_P5.08mm_Vertical_AnodeUp +Diode, 5W series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Vertical pin pitch 5.08mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_5W_P5.08mm_Vertical_KathodeUp +Diode, 5W series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Vertical pin pitch 5.08mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_5W_P10.16mm_Horizontal +Diode, 5W series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Horizontal pin pitch 10.16mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_5W_P12.70mm_Horizontal +Diode, 5W series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Horizontal pin pitch 12.7mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_A-405_P2.54mm_Vertical_AnodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P2.54mm_Vertical_KathodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P5.08mm_Vertical_AnodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P5.08mm_Vertical_KathodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P7.62mm_Horizontal +Diode, A-405 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Horizontal pin pitch 7.62mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P10.16mm_Horizontal +Diode, A-405 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Horizontal pin pitch 10.16mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P12.70mm_Horizontal +Diode, A-405 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Horizontal pin pitch 12.7mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-15_P2.54mm_Vertical_AnodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 2.54mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P2.54mm_Vertical_KathodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 2.54mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P3.81mm_Vertical_AnodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 3.81mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P3.81mm_Vertical_KathodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 3.81mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P5.08mm_Vertical_AnodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 5.08mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P5.08mm_Vertical_KathodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 5.08mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P10.16mm_Horizontal +Diode, DO-15 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Horizontal pin pitch 10.16mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P12.70mm_Horizontal +Diode, DO-15 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Horizontal pin pitch 12.7mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P15.24mm_Horizontal +Diode, DO-15 series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Horizontal pin pitch 15.24mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-27_P5.08mm_Vertical_AnodeUp +Diode, DO-27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Vertical pin pitch 5.08mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-27_P5.08mm_Vertical_KathodeUp +Diode, DO-27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Vertical pin pitch 5.08mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-27_P12.70mm_Horizontal +Diode, DO-27 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Horizontal pin pitch 12.7mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-27_P15.24mm_Horizontal +Diode, DO-27 series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Horizontal pin pitch 15.24mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P2.54mm_Vertical_AnodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 2.54mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P2.54mm_Vertical_KathodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 2.54mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P5.08mm_Vertical_AnodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 5.08mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P5.08mm_Vertical_KathodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 5.08mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P7.62mm_Horizontal +Diode, DO-34_SOD68 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Horizontal pin pitch 7.62mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P10.16mm_Horizontal +Diode, DO-34_SOD68 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Horizontal pin pitch 10.16mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P12.70mm_Horizontal +Diode, DO-34_SOD68 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Horizontal pin pitch 12.7mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P2.54mm_Vertical_AnodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 2.54mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P2.54mm_Vertical_KathodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 2.54mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P3.81mm_Vertical_AnodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 3.81mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P3.81mm_Vertical_KathodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 3.81mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P5.08mm_Vertical_AnodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 5.08mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P5.08mm_Vertical_KathodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 5.08mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P7.62mm_Horizontal +Diode, DO-35_SOD27 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Horizontal pin pitch 7.62mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P10.16mm_Horizontal +Diode, DO-35_SOD27 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Horizontal pin pitch 10.16mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P12.70mm_Horizontal +Diode, DO-35_SOD27 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Horizontal pin pitch 12.7mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P2.54mm_Vertical_AnodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P2.54mm_Vertical_KathodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P3.81mm_Vertical_AnodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=5.2*2.7mm^2, , https://www.diodes.com/assets/Package-Files/DO-41-Plastic.pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 3.81mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P3.81mm_Vertical_KathodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=5.2*2.7mm^2, , https://www.diodes.com/assets/Package-Files/DO-41-Plastic.pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 3.81mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P5.08mm_Vertical_AnodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P5.08mm_Vertical_KathodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P7.62mm_Horizontal +Diode, DO-41_SOD81 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Horizontal pin pitch 7.62mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P10.16mm_Horizontal +Diode, DO-41_SOD81 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Horizontal pin pitch 10.16mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P12.70mm_Horizontal +Diode, DO-41_SOD81 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Horizontal pin pitch 12.7mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-201AD_P3.81mm_Vertical_AnodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 3.81mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P3.81mm_Vertical_KathodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 3.81mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P5.08mm_Vertical_AnodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 5.08mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P5.08mm_Vertical_KathodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 5.08mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P12.70mm_Horizontal +Diode, DO-201AD series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Horizontal pin pitch 12.7mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P15.24mm_Horizontal +Diode, DO-201AD series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Horizontal pin pitch 15.24mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AE_P3.81mm_Vertical_AnodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 3.81mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P3.81mm_Vertical_KathodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 3.81mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P5.08mm_Vertical_AnodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 5.08mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P5.08mm_Vertical_KathodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 5.08mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P12.70mm_Horizontal +Diode, DO-201AE series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Horizontal pin pitch 12.7mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P15.24mm_Horizontal +Diode, DO-201AE series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Horizontal pin pitch 15.24mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201_P3.81mm_Vertical_AnodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 3.81mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P3.81mm_Vertical_KathodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 3.81mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P5.08mm_Vertical_AnodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 5.08mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P5.08mm_Vertical_KathodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 5.08mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P12.70mm_Horizontal +Diode, DO-201 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Horizontal pin pitch 12.7mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P15.24mm_Horizontal +Diode, DO-201 series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Horizontal pin pitch 15.24mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-247_Horizontal_TabDown +Diode, DO-247 series, Horizontal, TabDown, P 10.9mm +diode rectifier +0 +2 +2 +Diode_THT +D_DO-247_Horizontal_TabUp +Diode, DO-247 series, Horizontal, TabUp, P 10.9mm +diode rectifier +0 +2 +2 +Diode_THT +D_DO-247_Vertical +Diode, DO-247 series, Vertical, P 10.9mm +diode rectifier +0 +2 +2 +Diode_THT +D_P600_R-6_P7.62mm_Vertical_AnodeUp +Diode, P600_R-6 series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Vertical pin pitch 7.62mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_P600_R-6_P7.62mm_Vertical_KathodeUp +Diode, P600_R-6 series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Vertical pin pitch 7.62mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_P600_R-6_P12.70mm_Horizontal +Diode, P600_R-6 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Horizontal pin pitch 12.7mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_P600_R-6_P20.00mm_Horizontal +Diode, P600_R-6 series, Axial, Horizontal, pin pitch=20mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Horizontal pin pitch 20mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_T-1_P2.54mm_Vertical_AnodeUp +Diode, T-1 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Vertical pin pitch 2.54mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P2.54mm_Vertical_KathodeUp +Diode, T-1 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Vertical pin pitch 2.54mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P5.08mm_Horizontal +Diode, T-1 series, Axial, Horizontal, pin pitch=5.08mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Horizontal pin pitch 5.08mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P10.16mm_Horizontal +Diode, T-1 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Horizontal pin pitch 10.16mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P12.70mm_Horizontal +Diode, T-1 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Horizontal pin pitch 12.7mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +Diode_Bridge_15.1x15.1x6.3mm_P10.9mm +Single phase bridge rectifier case 15.1x15.1mm, pitch 10.9mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/pb1000.pdf +Diode Bridge PB10xxS +0 +4 +4 +Diode_THT +Diode_Bridge_15.2x15.2x6.3mm_P10.9mm +Single phase bridge rectifier case 15.2x15.2mm, pitch 10.9mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/kbpc600.pdf +Diode Bridge KBPC6xx +0 +4 +4 +Diode_THT +Diode_Bridge_15.7x15.7x6.3mm_P10.8mm +Single phase bridge rectifier case 15.7x15.7 +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_16.7x16.7x6.3mm_P10.8mm +Single phase bridge rectifier case 16.7x16.7 +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_19.0x3.5x10.0mm_P5.0mm +Vishay GBU rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88606/g3sba20.pdf +Vishay GBU rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_19.0x19.0x6.8mm_P12.7mm +Single phase bridge rectifier case 19x19mm, pitch 12.7mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/pb1000.pdf +Diode Bridge PB10xx +0 +4 +4 +Diode_THT +Diode_Bridge_28.6x28.6x7.3mm_P18.0mm_P11.6mm +Single phase bridge rectifier case 28.6x28.6mm, pitch 18.0mm & 11.6mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/kbpc1500fw.pdf +Diode Bridge KBPCxxxxWP +0 +4 +4 +Diode_THT +Diode_Bridge_32.0x5.6x17.0mm_P10.0mm_P7.5mm +Diotec 32x5.6x17mm rectifier package, 7.5mm/10mm pitch, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/b40c3700.pdf +Diotec rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_DIP-4_W5.08mm_P2.54mm +4-lead dip package for diode bridges, row spacing 5.08mm, pin-spacing 2.54mm, see http://www.vishay.com/docs/88898/b2m.pdf +DIL DIP PDIP 5.08mm 2.54 +0 +4 +4 +Diode_THT +Diode_Bridge_DIP-4_W7.62mm_P5.08mm +4-lead dip package for diode bridges, row spacing 7.62 mm (300 mils), see http://cdn-reichelt.de/documents/datenblatt/A400/HDBL101G_20SERIES-TSC.pdf +DIL DIP PDIP 5.08mm 7.62mm 300mil +0 +4 +4 +Diode_THT +Diode_Bridge_IXYS_GUFP +Three phase, Bridge, Rectifier +diode module +0 +5 +5 +Diode_THT +Diode_Bridge_Round_D8.9mm +4-lead round diode bridge package, diameter 8.9mm, pin pitch 5.08mm, see http://cdn-reichelt.de/documents/datenblatt/A400/W005M-W10M_SEP.PDF +diode bridge 8.9mm 8.85mm WOB pitch 5.08mm +0 +4 +4 +Diode_THT +Diode_Bridge_Round_D9.0mm +4-lead round diode bridge package, diameter 9.0mm, pin pitch 5.0mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/b40r.pdf +diode bridge 9.0mm 8.85mm WOB pitch 5.0mm +0 +4 +4 +Diode_THT +Diode_Bridge_Round_D9.8mm +4-lead round diode bridge package, diameter 9.8mm, pin pitch 5.08mm, see http://www.vishay.com/docs/88769/woo5g.pdf +diode bridge 9.8mm WOG pitch 5.08mm +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_GBL +Vishay GBL rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88609/gbl005.pdf +Vishay GBL rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_GBU +Vishay GBU rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88606/g3sba20.pdf +Vishay GBU rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBL +Vishay KBL rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88655/kbl005.pdf +Vishay KBL rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBPC1 +Single phase bridge rectifier case KBPC1, see http://www.vishay.com/docs/93585/vs-kbpc1series.pdf +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBPC6 +Single phase bridge rectifier case KBPC6, see http://www.vishay.com/docs/93585/vs-kbpc1series.pdf +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBPM +Vishay KBM rectifier package, 3.95mm pitch (http://www.farnell.com/datasheets/2238158.pdf, http://www.cdil.com/s/kbp2005_.pdf) +Vishay KBM rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBU +Vishay KBU rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88656/kbu4.pdf +Vishay KBU rectifier diode bridge +0 +4 +4 +Display +AG12864E +STN/FSTN LCD 128x64 dot https://www.digchip.com/datasheets/parts/datasheet/1121/AG-12864E-pdf.php +AG12864E Graphics Display 128x64 Ampire +0 +24 +20 +Display +Adafruit_SSD1306 +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI https://learn.adafruit.com/monochrome-oled-breakouts/downloads +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI +0 +8 +8 +Display +Adafruit_SSD1306_No_Mounting_Holes +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI https://learn.adafruit.com/monochrome-oled-breakouts/downloads +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI +0 +8 +8 +Display +CR2013-MI2120 +CR2013-MI2120 ILI9341 LCD Breakout http://pan.baidu.com/s/11Y990 +CR2013-MI2120 ILI9341 LCD Breakout +0 +18 +14 +Display +EA-eDIP128B-XXX +LCD-graphical display with LED backlight 128x64 RS-232 I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip128-6e.pdf +LCD-graphical display with LED backlight 128x64 RS-232 I2C or SPI +0 +32 +32 +Display +EA_DOGS104X-A +LCD 4x10 character 3.3V VDD I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/doma/dogs104e.pdf +LCD 4x10 character 3.3V VDD I2C or SPI +0 +14 +14 +Display +EA_DOGXL160-7 +Grapchical,Display,LCD,160x104 http://www.lcd-module.com/eng/pdf/grafik/dogxl160-7e.pdf +EA_DOGXL160-7 +0 +22 +22 +Display +EA_DOGXL160-7_Backlight +Grapchical,Display,LCD,160x104 http://www.lcd-module.com/eng/pdf/grafik/dogxl160-7e.pdf +EA_DOGXL160-7_Backlight +0 +22 +22 +Display +EA_T123X-I2C +http://www.lcd-module.de/pdf/doma/t123-i2c.pdf +3 Line 12 character wide alpha numeric LCD +0 +6 +6 +Display +EA_eDIP160-XXX +LCD-graphical display with LED backlight 160x104 RS-232 I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip160-7e.pdf +LCD-graphical display with LED backlight 160x104 RS-232 I2C or SPI +0 +40 +40 +Display +EA_eDIP240-XXX +LCD graphical display LED backlight 240x128 http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip240-7e.pdf +LCD graphical display LED backlight 240x128 +0 +40 +40 +Display +EA_eDIP320X-XXX +LCD display 320x340 RS-232 I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip320-8e.pdf +LCD display 320x340 RS-232 I2C or SPI +0 +48 +48 +Display +EA_eDIPTFT32-XXX +TFT-graphic display 320x240 16 bit colour with led backlight http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft32-ae.pdf +TFT-graphic display 320x240 16 bit colour with led backlight +0 +40 +40 +Display +EA_eDIPTFT43-ATC +http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft43-ae.pdf +TFT graphical display 480x272 16-bit colour with LED backlight +0 +40 +40 +Display +EA_eDIPTFT43-XXX +TFT graphical display 480x272 16-bit colour with LED backlight http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft43-ae.pdf +TFT graphical display 480x272 16-bit colour with LED backlight +0 +40 +40 +Display +EA_eDIPTFT57-XXX +http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft57-ae.pdf +TFT-graphic display 640x480 16 bit colour +0 +48 +48 +Display +EA_eDIPTFT70-ATC +TFT-graphical display 800x480 16-bit colours with capacitive touch panel http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft70-ae.pdf +TFT-graphical display 800x480 16-bit colours with capacitive touch panel +0 +48 +48 +Display +EA_eDIPTFT70-XXX +TFT-graphical display 800x480 16-bit colours http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft70-ae.pdf +TFT-graphical display 800x480 16-bit colours and touch display +0 +48 +48 +Display +HDSM-441B_HDSM-443B +2 Digit 7 segemnt blue LED, right hand decimal, https://docs.broadcom.com/docs/AV02-1589EN +2 Digit 7 segment blue LED +0 +10 +10 +Display +HDSM-541B_HDSM-543B +2 digit 7 segement blue LED with right hand decimal, https://docs.broadcom.com/docs/AV02-1588EN +2 digit 7 segement blue LED with right hand decimal +0 +10 +10 +Display +HDSP-48xx +10-Element Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Bar Graph Array +0 +20 +20 +Display +HDSP-4830 +10-Element Red Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Bar Graph Array +0 +20 +20 +Display +HDSP-4832 +10-Element Red Yellow Green Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Yellow Green Bar Graph Array +0 +20 +20 +Display +HDSP-4836 +10-Element Red Yellow Green Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Yellow Green Bar Graph Array +0 +20 +20 +Display +HDSP-4840 +10-Element Yellow Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Yellow Bar Graph Array +0 +20 +20 +Display +HDSP-4850 +10-Element Green Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Green Bar Graph Array +0 +20 +20 +Display +HLCP-J100 +10-Element Red Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Bar Graph Array +0 +20 +20 +Display +HY1602E +http://www.icbank.com/data/ICBShop/board/HY1602E.pdf +LCD 16x2 Alphanumeric 16pin +0 +20 +16 +Display +LCD-016N002L +16 x 2 Character LCD, http://www.vishay.com/product?docid=37299 +LCD-016N002L 16 x 2 Character LCD +0 +24 +20 +Display +LM16255 +LCD LM16255 16x2 character http://www.datasheetlib.com/datasheet/259542/lm16255_sharp-electronics.html +LCD 12x2 +0 +14 +14 +Display +NHD-0420H1Z +NHD-0420H1Z LCD http://www.newhavendisplay.com/specs/NHD-0420H1Z-FSW-GBW-33V3.pdf +NHD-0420H1Z LCD +0 +16 +16 +Display +NHD-C0220BiZ +NHD-C0220BiZ LCD http://www.newhavendisplay.com/specs/NHD-C0220BiZ-FSW-FBW-3V3M.pdf +NHD-C0220BiZ LCD +0 +10 +10 +Display +OLED-128O064D +128x64 OLED display +display oled +0 +30 +30 +Display +RC1602A +http://www.raystar-optronics.com/down.php?ProID=18 +LCD 16x2 Alphanumeric 16pin +0 +22 +18 +Display +WC1602A +LCD 16x2 http://www.wincomlcd.com/pdf/WC1602A-SFYLYHTC06.pdf +LCD 16x2 Alphanumeric 16pin +0 +20 +16 +Display_7Segment +7SEGMENT-LED__HDSM531_HDSM533_SMD +7-Segment Display, HDSM53x, https://docs.broadcom.com/docs/AV02-0713EN +7segment LED HDSM531 HDSM533 +0 +10 +10 +Display_7Segment +7SegmentLED_LTS6760_LTS6780 +7-Segment Display, LTS67x0, http://optoelectronics.liteon.com/upload/download/DS30-2001-355/S6760jd.pdf +7Segment LED LTS6760 LTS6780 +0 +10 +10 +Display_7Segment +AD-121F2 +Single Digit 7-segment RGB LED Display, 1-inch digit height, common anode, http://usasyck.com/products/AD-121F2_cat_e.pdf +RGB LED digit +0 +22 +22 +Display_7Segment +AFF_2x7SEG-DIGIT_10mm +Afficheur 7 segments 10mm DIGIT +AFFICHEUR +0 +16 +16 +Display_7Segment +CA56-12CGKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12CGKWA(Ver.9A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12EWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CA56-12EWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SEKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12SEKWA(Ver.7A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SRWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CA56-12SRWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SURKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12SURKWA(Ver.8A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SYKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12SYKWA(Ver.6A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CC56-12GWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CA56-11GWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CC56-12YWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CC56-12YWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +DA04-11CGKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11CGKWA(Ver.6A).pdf +Dubble digit green 7 segment LED display +0 +16 +16 +Display_7Segment +DA04-11SEKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11SEKWA(Ver.9A).pdf +Dubble digit super bright orange 7 segment LED display +0 +16 +16 +Display_7Segment +DA04-11SURKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11SURKWA(Ver.10A).pdf +Dubble digit hyper red 7 segment LED display +0 +16 +16 +Display_7Segment +DA04-11SYKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11SYKWA(Ver.6A).pdf +Dubble digit super bright yellow 7 segment LED display +0 +16 +16 +Display_7Segment +DA56-11CGKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11CGKWA(Ver.16A).pdf +Double digit seven segment green LED display +0 +18 +18 +Display_7Segment +DA56-11SEKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11SEKWA(Ver.9A).pdf +Double digit seven segment super bright orange LED display +0 +18 +18 +Display_7Segment +DA56-11SURKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11SURKWA(Ver.11A).pdf +Double digit seven segment hyper red LED display +0 +18 +18 +Display_7Segment +DA56-11SYKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11SYKWA(Ver.11A).pdf +Double digit seven segment super bright yellow LED display +0 +18 +18 +Display_7Segment +DE113-XX-XX +http://www.display-elektronik.de/filter/DE113-RS-20_635.pdf +3 1/5 digit LOW BAT + 7-Segment LCD +0 +40 +40 +Display_7Segment +DE114-RS-20 +http://www.display-elektronik.de/filter/DE113-RS-20_635.pdf +3 1/5 digit reflective LCD LOW-BAT + 7-Segment +0 +40 +40 +Display_7Segment +DE122-XX-XX +http://www.display-elektronik.de/filter/DE122-RS-20_635.pdf +6 digit 7 segment LCD +0 +50 +50 +Display_7Segment +DE170-XX-XX +http://www.display-elektronik.de/filter/DE170-RS-20_75.pdf +3 1/5 digit reflective arrow bat + 7 segment LCD +0 +40 +40 +Display_7Segment +ELD_426XXXX +http://www.everlight.com/file/ProductFile/D426SYGWA-S530-E2.pdf +Double digit 7 segment brilliant yellow green LED +0 +10 +10 +Display_7Segment +HDSP-7401 +One digit 7 segment yellow, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment yellow +0 +10 +10 +Display_7Segment +HDSP-7507 ++-1 overflow 7 segment high efficiency red, https://docs.broadcom.com/docs/AV02-2553EN ++-1 overflow 7 segment high efficiency red +0 +10 +10 +Display_7Segment +HDSP-7801 +One digit 7 segment green, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment green +0 +10 +10 +Display_7Segment +HDSP-7807 ++-1 overflow 7 segment green, https://docs.broadcom.com/docs/AV02-2553EN ++-1 overflow 7 segment green +0 +10 +10 +Display_7Segment +HDSP-A151 +One digit 7 segment red, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment high efficiency red +0 +10 +10 +Display_7Segment +HDSP-A401 +One digit 7 segment orange, common anode, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment orange common anode +0 +10 +10 +Display_7Segment +KCSC02-105 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-105(Ver.9A).pdf +Single digit 7 segement hyper red LED +0 +10 +10 +Display_7Segment +KCSC02-106 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-106(Ver.10A).pdf +Single digit 7 segement super bright orange LED +0 +10 +10 +Display_7Segment +KCSC02-107 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-107(Ver.9A).pdf +Single digit 7 segement super bright yellow LED +0 +10 +10 +Display_7Segment +KCSC02-123 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-123(Ver.10A).pdf +Single digit 7 segement super bright yellow LED +0 +10 +10 +Display_7Segment +KCSC02-136 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-136(Ver.6B).pdf +Single digit 7 segement super bright yellow LED +0 +10 +10 +Display_7Segment +MAN71A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment red LED with right dot +0 +14 +14 +Display_7Segment +MAN72A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment red LED with left dot +0 +14 +14 +Display_7Segment +MAN73A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +Overflow +- 1 red LED +0 +14 +14 +Display_7Segment +MAN3410A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment green LED with dot +0 +14 +14 +Display_7Segment +MAN3420A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment green LED with left dot +0 +14 +14 +Display_7Segment +MAN3610A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment orange LED with right dot +0 +14 +14 +Display_7Segment +MAN3620A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment orange LED with left dot +0 +14 +14 +Display_7Segment +MAN3630A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +Overflow +- 1 orange LED +0 +14 +14 +Display_7Segment +MAN3810A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment yellow LED with right dot +0 +14 +14 +Display_7Segment +MAN3820A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment yellow LED with left dot +0 +14 +14 +Display_7Segment +SA15-11xxx +http://www.kingbrightusa.com/images/catalog/SPEC/SA15-11SRWA.pdf +SA15-11xxx single digit 7 segment display 38.1mm 1.5inch +0 +10 +10 +Display_7Segment +SBC18-11SURKCGKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/SBC18-11SURKCGKWA(Ver.6A).pdf +single digit 7 segemnt red/green LED +0 +10 +10 +Display_7Segment +Sx39-1xxxxx +Single digit 7 segment LED display in red, yellow or green colour http://www.kingbrightusa.com/images/catalog/SPEC/sa39-11ewa.pdf +One digit LED 7 segment SA39-11 SC39-11 SA39-12 SC39-12 +0 +10 +10 +Ferrite_THT +LairdTech_28C0236-0JW-10 +Ferrite, vertical, LairdTech 28C0236-0JW-10, https://assets.lairdtech.com/home/brandworld/files/28C0236-0JW-10.pdf, JW Miller core https://www.bourns.com/products/magnetic-products/j.w.-miller-through-hole-ferrite-beads-emi-filters +Ferrite vertical LairdTech 28C0236-0JW-10 +0 +2 +2 +Fiducial +Fiducial_0.5mm_Mask1.5mm +Circular Fiducial, 0.5mm bare copper, 1.5mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_0.5mm_Mask1mm +Circular Fiducial, 0.5mm bare copper, 1mm soldermask opening (Level C) +fiducial +0 +1 +0 +Fiducial +Fiducial_0.75mm_Mask1.5mm +Circular Fiducial, 0.75mm bare copper, 1.5mm soldermask opening (Level B) +fiducial +0 +1 +0 +Fiducial +Fiducial_0.75mm_Mask2.25mm +Circular Fiducial, 0.75mm bare copper, 2.25mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_1.5mm_Mask3mm +Circular Fiducial, 1.5mm bare copper, 3mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_1.5mm_Mask4.5mm +Circular Fiducial, 1.5mm bare copper, 4.5mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_1mm_Mask2mm +Circular Fiducial, 1mm bare copper, 2mm soldermask opening (Level A) +fiducial +0 +1 +0 +Fiducial +Fiducial_1mm_Mask3mm +Circular Fiducial, 1mm bare copper, 3mm soldermask opening (recommended) +fiducial +0 +1 +0 +Filter +Filter_1109-5_1.1x0.9mm +5-pin SAW filter package - 1.1x0.9 mm Body; (see https://www.murata.com/~/media/webrenewal/support/library/catalog/products/filter/rf/p73e.ashx?la=en-gb) +Filter 5 +0 +5 +5 +Filter +Filter_1411-5_1.4x1.1mm +5-pin filter package - 1.4x1.1 mm Body; (see https://global.kyocera.com/prdct/electro/product/pdf/sf14_tdlte.pdf) +Filter 5 +0 +5 +5 +Filter +Filter_Bourns_SRF0905_6.0x9.2mm +https://www.bourns.com/docs/Product-Datasheets/SRF0905.pdf +Line Filter +0 +4 +4 +Filter +Filter_FILTERCON_1FPxx +0.5A, 250VAC, 50/60Hz line filter (https://filtercon.com.pl/wp-content/uploads/2019/07/Karta-katalogowa-FP-12-1.pdf) +EMI filter +0 +4 +4 +Filter +Filter_Mini-Circuits_FV1206 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206.pdf +Mini-Circuits Filter SMD 1206 +0 +6 +4 +Filter +Filter_Mini-Circuits_FV1206-1 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-1.pdf +Mini-Circuits Filter SMD 1206 +0 +6 +6 +Filter +Filter_Mini-Circuits_FV1206-4 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-4.pdf +Mini-Circuits Filter SMD 1206 +0 +8 +4 +Filter +Filter_Mini-Circuits_FV1206-5 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-5.pdf +Mini-Circuits Filter SMD 1206 +0 +8 +4 +Filter +Filter_Mini-Circuits_FV1206-6 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-6.pdf +Mini-Circuits Filter SMD 1206 +0 +14 +8 +Filter +Filter_Mini-Circuits_FV1206-7 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-7.pdf +Mini-Circuits Filter SMD 1206 +0 +5 +3 +Filter +Filter_Murata_BNX025 +https://www.murata.com/en-us/products/productdata/8796778004510/QNFH9101.pdf?1496719830000 +EMI Filter +0 +6 +4 +Filter +Filter_Murata_BNX025_ThermalVias +https://www.murata.com/en-us/products/productdata/8796778004510/QNFH9101.pdf?1496719830000 +EMI Filter +0 +19 +4 +Filter +Filter_Schaffner_FN405 +Compact PCB mounting EMI filter (https://www.schaffner.com/de/produkte/download/product/datasheet/fn-405-pcb-mounting-filter/) +EMI filter +0 +5 +5 +Filter +Filter_Schaffner_FN406 +Ultra Compact EMC Filter (https://www.schaffner.com/products/download/product/datasheet/fn-406-ultra-compact-emc-filter/) +emi filter +0 +5 +5 +Fuse +Fuse_0402_1005Metric +Fuse SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_0402_1005Metric_Castellated +Fuse SMD 0402 (1005 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_0402_1005Metric_Pad0.77x0.64mm_HandSolder +Fuse SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_0603_1608Metric +Fuse SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_0603_1608Metric_Castellated +Fuse SMD 0603 (1608 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_0603_1608Metric_Pad1.05x0.95mm_HandSolder +Fuse SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_0805_2012Metric +Fuse SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_0805_2012Metric_Castellated +Fuse SMD 0805 (2012 Metric), castellated end terminal, IPC_7351. (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_0805_2012Metric_Pad1.15x1.40mm_HandSolder +Fuse SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_1206_3216Metric +Fuse SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_1206_3216Metric_Castellated +Fuse SMD 1206 (3216 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_1206_3216Metric_Pad1.42x1.75mm_HandSolder +Fuse SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_1210_3225Metric +Fuse SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_1210_3225Metric_Castellated +Fuse SMD 1210 (3225 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_1210_3225Metric_Pad1.42x2.65mm_HandSolder +Fuse SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_1812_4532Metric +Fuse SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_1812_4532Metric_Castellated +Fuse SMD 1812 (4532 Metric), castellated end terminal, IPC_7351. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Fuse SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2010_5025Metric +Fuse SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2010_5025Metric_Castellated +Fuse SMD 2010 (5025 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2010_5025Metric_Pad1.52x2.65mm_HandSolder +Fuse SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2512_6332Metric +Fuse SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2512_6332Metric_Castellated +Fuse SMD 2512 (6332 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2512_6332Metric_Pad1.52x3.35mm_HandSolder +Fuse SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2816_7142Metric +Fuse SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2816_7142Metric_Castellated +Fuse SMD 2816 (7142 Metric), castellated end terminal, IPC_7351. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Fuse SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2920_7451Metric +Fuse SMD 2920 (7451 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://www.megastar.com/products/fusetronic/polyswitch/PDF/smd2920.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2920_7451Metric_Castellated +Fuse SMD 2920 (7451 Metric), castellated end terminal, IPC_7351. (Body size from: http://www.megastar.com/products/fusetronic/polyswitch/PDF/smd2920.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2920_7451Metric_Pad2.10x5.45mm_HandSolder +Fuse SMD 2920 (7451 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://www.megastar.com/products/fusetronic/polyswitch/PDF/smd2920.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0005FF_L8.3mm_W3.8mm +Fuse 0ZRE0005FF, BelFuse, Radial Leaded PTC, https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0008FF_L8.3mm_W3.8mm +Fuse 0ZRE0008FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0012FF_L8.3mm_W3.8mm +Fuse 0ZRE0012FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0016FF_L9.9mm_W3.8mm +Fuse 0ZRE0016FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0025FF_L9.6mm_W3.8mm +Fuse 0ZRE0025FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0033FF_L11.4mm_W3.8mm +Fuse 0ZRE0033FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0040FF_L11.5mm_W3.8mm +Fuse 0ZRE0040FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0055FF_L14.0mm_W4.1mm +Fuse 0ZRE0055FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0075FF_L11.5mm_W4.8mm +Fuse 0ZRE0075FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0100FF_L18.7mm_W5.1mm +Fuse 0ZRE0100FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0125FF_L21.2mm_W5.3mm +Fuse 0ZRE0125FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0150FF_L23.4mm_W5.3mm +Fuse 0ZRE0150FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0200FF_L24.9mm_W6.1mm +Fuse 0ZRE0200FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_Blade_ATO_directSolder +car blade fuse direct solder +car blade fuse +0 +2 +2 +Fuse +Fuse_Blade_Mini_directSolder +car blade fuse mini, direct solder +car blade fuse mini +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG300 +PTC Resettable Fuse, Ihold = 3.0A, Itrip=5.1A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG400 +PTC Resettable Fuse, Ihold = 4.0A, Itrip=6.8A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG500 +PTC Resettable Fuse, Ihold = 5.0A, Itrip=8.5A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG600 +PTC Resettable Fuse, Ihold = 6.0A, Itrip=10.2A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG650 +PTC Resettable Fuse, Ihold = 6.5A, Itrip=11.1A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG700 +PTC Resettable Fuse, Ihold = 7.0A, Itrip=11.9A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG800 +PTC Resettable Fuse, Ihold = 8.0A, Itrip=13.6A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG900 +PTC Resettable Fuse, Ihold = 9.0A, Itrip=15.3A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG1000 +PTC Resettable Fuse, Ihold = 10.0A, Itrip=17.0A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG1100 +PTC Resettable Fuse, Ihold = 11.0A, Itrip=18.7A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT050 +PTC Resettable Fuse, Ihold = 0.5A, Itrip=0.92A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT070 +PTC Resettable Fuse, Ihold = 0.7A, Itrip=1.4A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT100 +PTC Resettable Fuse, Ihold = 1.0A, Itrip=1.8A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT200 +PTC Resettable Fuse, Ihold = 2.0A, Itrip=3.8A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT300 +PTC Resettable Fuse, Ihold = 3.0A, Itrip=6.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT400 +PTC Resettable Fuse, Ihold = 4.0A, Itrip=7.5A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT500 +PTC Resettable Fuse, Ihold = 5.0A, Itrip=9.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT550 +PTC Resettable Fuse, Ihold = 5.5A, Itrip=10.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT600 +PTC Resettable Fuse, Ihold = 6.0A, Itrip=10.8A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT650 +PTC Resettable Fuse, Ihold = 6.5A, Itrip=12.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT700 +PTC Resettable Fuse, Ihold = 7.0A, Itrip=13.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT750 +PTC Resettable Fuse, Ihold = 7.5A, Itrip=13.1A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT800 +PTC Resettable Fuse, Ihold = 8.0A, Itrip=15.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT900 +PTC Resettable Fuse, Ihold = 9.0A, Itrip=16.5A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT1000 +PTC Resettable Fuse, Ihold = 10.0A, Itrip=18.5A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT1100 +PTC Resettable Fuse, Ihold = 11.0A, Itrip=20.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT1300 +PTC Resettable Fuse, Ihold = 13.0A, Itrip=24.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-SM_7.98x5.44mm +https://www.bourns.com/docs/Product-Datasheets/mfsm.pdf +bourns ptc resettable fuse polyfuse MF-SM MF-SMHT +0 +2 +2 +Fuse +Fuse_Bourns_MF-SM_9.5x6.71mm +https://www.bourns.com/docs/Product-Datasheets/mfsm.pdf +bourns ptc resettable fuse polyfuse MF-SM MF-SMHT +0 +2 +2 +Fuse +Fuse_Littelfuse-LVR100 +Littelfuse, resettable fuse, PTC, polyswitch LVR100, Ih 1A http://www.littelfuse.com/~/media/electronics/datasheets/resettable_ptcs/littelfuse_ptc_lvr_catalog_datasheet.pdf.pdf +LVR100 PTC resettable polyswitch +0 +2 +2 +Fuse +Fuse_Littelfuse-LVR125 +Littelfuse, resettable fuse, PTC, polyswitch LVR125, Ih 1.25A, http://www.littelfuse.com/~/media/electronics/datasheets/resettable_ptcs/littelfuse_ptc_lvr_catalog_datasheet.pdf.pdf +LVR125 PTC resettable polyswitch +0 +2 +2 +Fuse +Fuse_Littelfuse-LVR200 +Littelfuse, resettable fuse, PTC, polyswitch LVR200, Ih 2A, http://www.littelfuse.com/~/media/electronics/datasheets/resettable_ptcs/littelfuse_ptc_lvr_catalog_datasheet.pdf.pdf +LVR200 PTC resettable polyswitch +0 +2 +2 +Fuse +Fuse_Littelfuse-NANO2-451_453 +Littelfuse NANO2 https://www.littelfuse.com/~/media/electronics/datasheets/fuses/littelfuse_fuse_451_453_datasheet.pdf.pdf +Fuse Nano2 +0 +2 +2 +Fuse +Fuse_Littelfuse_372_D8.50mm +Fuse, Littelfuse, 372, 8.5x8mm, https://www.littelfuse.com/~/media/electronics/datasheets/fuses/littelfuse_fuse_372_datasheet.pdf.pdf +fuse tht radial +0 +2 +2 +Fuse +Fuse_Littelfuse_395Series +Fuse, TE5, Littelfuse/Wickmann, No. 460, No560, +Fuse TE5 Littelfuse/Wickmann No. 460 No560 +0 +2 +2 +Fuse +Fuse_Schurter_UMT250 +Surface Mount Fuse, 3 x 10.1 mm, Time-Lag T, 250 VAC, 125 VDC (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_UMT_250.pdf) +Schurter fuse smd +0 +2 +2 +Fuse +Fuse_Schurter_UMZ250 +Surface Mount Fuse with Clip, 4.2 x 11.1 mm, Time-Lag T, 250 VAC, 125 VDC (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_UMZ_250.pdf) +fuse smd mount holder +0 +2 +2 +Fuse +Fuse_SunFuse-6HP +SunFuse Ceramic Slow Blow Fuse 6H_6HP.PDF +UL/CSA 6x32mm Ceramic Slow Blow Fuse +0 +2 +2 +Fuse +Fuseholder_Blade_ATO_Littelfuse_Pudenz_2_Pin +Fuseholder ATO Blade littelfuse Pudenz 2 Pin +Fuseholder ATO Blade littelfuse Pudenz 2 Pin +0 +2 +2 +Fuse +Fuseholder_Blade_Mini_Keystone_3568 +fuse holder, car blade fuse mini, http://www.keyelco.com/product-pdf.cfm?p=306 +car blade fuse mini +0 +4 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Bulgin_FX0456_Vertical_Closed +Fuseholder, 5x20, closed, vertical, Bulgin, FX0456, https://www.bulgin.com/products/pub/media/bulgin/data/Fuseholders.pdf +Fuseholder 5x20 closed vertical Bulgin FX0456 Sicherungshalter +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Bulgin_FX0457_Horizontal_Closed +Fuseholder, 5x20, closed, horizontal, Bulgin, FX0457, Sicherungshalter, +Fuseholder 5x20 closed horizontal Bulgin FX0457 Sicherungshalter +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_EATON_H15-V-1_Vertical_Closed +PCB fuse holders for 5 mm x 20 mm fuses; 250V; 10A (http://www.cooperindustries.com/content/dam/public/bussmann/Electronics/Resources/product-datasheets/bus-elx-ds-4426-h15.pdf) +fuse holder vertical 5x20mm +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_EATON_HBV_Vertical_Closed +5 mm x 20 mm fuse holders; Vertical w/ Stability Pins; 250V; 6.3-16A (http://www.cooperindustries.com/content/dam/public/bussmann/Electronics/Resources/product-datasheets/Bus_Elx_DS_2118_HB_PCB_Series.pdf) +fuse holder vertical 5x20mm +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_EATON_HBW_Vertical_Closed +5 mm x 20 mm fuse holders; Vertical w/o Stability Pins; 250V; 6.3-16A (http://www.cooperindustries.com/content/dam/public/bussmann/Electronics/Resources/product-datasheets/Bus_Elx_DS_2118_HB_PCB_Series.pdf) +fuse holder vertical 5x20mm +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_0031_8201_Horizontal_Open +Fuseholder horizontal open, 5x20mm, 500V, 16A, Schurter 0031.8201, https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_OGN.pdf +Fuseholder horizontal open 5x20 Schurter 0031.8201 +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_FAB_0031-355x_Horizontal_Closed +Fuseholder 5x20mm horizontal Shurter model FAB, Suitable for order numbers 0031.3551 and 0031.3558 (https://www.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FAB.pdf) +Fuseholder 5x20mm closed horizontal +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_FPG4_Vertical_Closed +Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap/Fingergrip, vertical, IEC 60335-1; 250VAC/10A VDE; 500V/16A UL/CSA (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FPG4.pdf) +fuse holder vertical 5x20mm +0 +4 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_FUP_0031.2510_Horizontal_Closed +Shock-Safe closed Fuseholder, Schurter FUP Series, 5.0 x 20mm, Slotted Cap, horizontal, 500 VAC 4W/16A (VDE), 600V 30A (UL/CSA), order numbers: 0031.2510 (0031.2500 + 0031.2323), http://www.schurter.ch/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FUP.pdf +Fuseholder 5x20mm horizontal closed +0 +3 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_OGN-SMD_Horizontal_Open +Fuseholder horizontal open, 5x20mm, 500V, 16A (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_OGN-SMD.pdf) +Fuseholder horizontal open 5x20 Schurter 0031.8221 +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Stelvio-Kontek_PTF78_Horizontal_Open +https://www.tme.eu/en/Document/3b48dbe2b9714a62652c97b08fcd464b/PTF78.pdf +Fuseholder horizontal open 5x20 Stelvio-Kontek PTF/78 +0 +2 +2 +Fuse +Fuseholder_Cylinder-6.3x32mm_Schurter_0031-8002_Horizontal_Open +Fuseholder, horizontal, open, 6.3x32, Schurter, 0031.8002, https://www.schurter.com/en/datasheet/typ_OG__Holder__6.3x32.pdf +Fuseholder horizontal open 6.3x32 Schurter 0031.8002 +0 +2 +2 +Fuse +Fuseholder_Cylinder-6.3x32mm_Schurter_FUP_0031.2520_Horizontal_Closed +Shock-Safe closed Fuseholder, Schurter FUP Series, 6.3 x 32 mm, Slotted Cap, horizontal, 500 VAC 4W/16A (VDE), 600V 30A (UL/CSA), order numbers: 0031.2520 (0031.2500 + 0031.2321), http://www.schurter.ch/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FUP.pdf +Fuseholder 6.3x32mm horizontal closed +0 +3 +2 +Fuse +Fuseholder_Littelfuse_Nano2_157x +Littelfuse NANO2 holder, https://www.littelfuse.com/~/media/electronics/datasheets/fuses/littelfuse_fuse_157_datasheet.pdf.pdf +SMD Nano2 holder +0 +2 +2 +Fuse +Fuseholder_TR5_Littelfuse_No560_No460 +Fuse, Fuseholder, TR5, Littelfuse/Wickmann, No. 460, No560, https://www.littelfuse.com/~/media/electronics/datasheets/fuse_holders/littelfuse_fuse_holder_559_560_datasheet.pdf.pdf +Fuse Fuseholder TR5 Littelfuse/Wickmann No. 460 No560 +0 +2 +2 +Heatsink +Heatsink_35x26mm_1xFixation3mm_Fischer-SK486-35 +Heatsink, 35mm x 26mm, 1x Fixation 3mm, Fischer SK486-35 +heatsink +0 +1 +1 +Heatsink +Heatsink_38x38mm_SpringFixation +Heatsink, 38x38mm, Spring Fixation, diagonal, +heatsink +0 +4 +1 +Heatsink +Heatsink_62x40mm_2xFixation3mm +Heatsink, 62 x 40mm, 2x 3mm Drills, +heatsink +0 +2 +1 +Heatsink +Heatsink_125x35x50mm_3xFixationM3 +Heatsink, 125x35x50mm, 3 fixation holes 3.2mm +heatsink +0 +0 +0 +Heatsink +Heatsink_AAVID_573300D00010G_TO-263 +Heatsink, 12.70mm x 26.16mm x 10.16, SMD, 18K/W, TO-263, D2 Pak, https://www.shopaavid.com/Product/573300D00000G +Heatsink AAVID TO-263 D2 Pak +0 +2 +1 +Heatsink +Heatsink_Aavid-TV5G_TO220_Horizontal +Heatsink TV5G TO-220 Horizontal, https://www.shopaavid.com/Product/TV-5G +Heatsink TV5G TO-220 Horizontal +0 +0 +0 +Heatsink +Heatsink_Fischer_FK224xx2201_25x8.3mm +25x8.3mm Heatsink, 18K/W, TO-220, https://www.fischerelektronik.de/web_fischer/en_GB/$catalogue/fischerData/PR/FK224_220_1_/datasheet.xhtml?branch=heatsinks +heatsink TO-220 +0 +2 +1 +Heatsink +Heatsink_Fischer_FK24413D2PAK_26x13mm +26x13 mm SMD heatsink for TO-252 TO-263 TO-268, https://www.fischerelektronik.de/pim/upload/fischerData/cadpdf/base/fk_244_13_d2_pak.pdf +heatsink TO-252 TO-263 TO-268 +0 +2 +1 +Heatsink +Heatsink_Fischer_SK104-STC-STIC_35x13mm_2xDrill2.5mm +Heatsink, 35mm x 13mm, 2x Fixation 2,5mm Drill, Soldering, Fischer SK104-STC-STIC, +Heatsink fischer TO-220 +0 +2 +1 +Heatsink +Heatsink_Fischer_SK104-STCB_35x13mm__2xDrill3.5mm_ScrewM3 +Heatsink, 35mm x 13mm, 2x Fixation 2,5mm Drill, Soldering, Fischer SK104-STC-STIC, +Heatsink fischer TO-220 +0 +2 +1 +Heatsink +Heatsink_Fischer_SK129-STS_42x25mm_2xDrill2.5mm +Heatsink, Fischer SK129 +heatsink fischer +0 +2 +1 +Heatsink +Heatsink_SheetType_50x7mm_2Fixations +Heatsink, Sheet type, 50x7mm, 2 fixations (solder), +Heatsink sheet +0 +2 +1 +Heatsink +Heatsink_Stonecold_HS-132_32x14mm_2xFixation1.5mm +Heatsink, StoneCold HS +heatsink +0 +2 +1 +Inductor_SMD +L_6.3x6.3_H3 +Choke, SMD, 6.3x6.3mm 3mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_7.3x7.3_H3.5 +Choke, SMD, 7.3x7.3mm 3.5mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_7.3x7.3_H4.5 +Choke, SMD, 7.3x7.3mm 4.5mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_10.4x10.4_H4.8 +Choke, SMD, 10.4x10.4mm 4.8mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_12x12mm_H4.5mm +Choke, SMD, 12x12mm 4.5mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_12x12mm_H6mm +Choke, SMD, 12x12mm 6mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_12x12mm_H8mm +Choke, SMD, 12x12mm 8mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_0201_0603Metric +Inductor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +inductor +0 +4 +2 +Inductor_SMD +L_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Inductor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +4 +2 +Inductor_SMD +L_0402_1005Metric +Inductor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_0402_1005Metric_Pad0.77x0.64mm_HandSolder +Inductor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_0603_1608Metric +Inductor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_0603_1608Metric_Pad1.05x0.95mm_HandSolder +Inductor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_0805_2012Metric +Inductor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_0805_2012Metric_Pad1.05x1.20mm_HandSolder +Inductor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_0805_2012Metric_Pad1.15x1.40mm_HandSolder +Inductor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_01005_0402Metric +Inductor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +inductor +0 +4 +2 +Inductor_SMD +L_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Inductor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +4 +2 +Inductor_SMD +L_1008_2520Metric +Inductor SMD 1008 (2520 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://ecsxtal.com/store/pdf/ECS-MPI2520-SMD-POWER-INDUCTOR.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1008_2520Metric_Pad1.43x2.20mm_HandSolder +Inductor SMD 1008 (2520 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://ecsxtal.com/store/pdf/ECS-MPI2520-SMD-POWER-INDUCTOR.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1206_3216Metric +Inductor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1206_3216Metric_Pad1.22x1.90mm_HandSolder +Inductor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1206_3216Metric_Pad1.42x1.75mm_HandSolder +Inductor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1210_3225Metric +Inductor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1210_3225Metric_Pad1.42x2.65mm_HandSolder +Inductor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1806_4516Metric +Inductor SMD 1806 (4516 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.modelithics.com/models/Vendor/MuRata/BLM41P.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1806_4516Metric_Pad1.57x1.80mm_HandSolder +Capacitor SMD 1806 (4516 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.modelithics.com/models/Vendor/MuRata/BLM41P.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1812_4532Metric +Inductor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Inductor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_2010_5025Metric +Inductor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_2010_5025Metric_Pad1.52x2.65mm_HandSolder +Inductor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_2512_6332Metric +Inductor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_2512_6332Metric_Pad1.52x3.35mm_HandSolder +Inductor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_2816_7142Metric +Inductor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Inductor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_Abracon_ASPI-0630LR +smd shielded power inductor https://abracon.com/Magnetics/power/ASPI-0630LR.pdf +inductor abracon smd shielded +0 +2 +2 +Inductor_SMD +L_Abracon_ASPI-3012S +smd shielded power inductor http://www.abracon.com/Magnetics/power/ASPI-3012S.pdf +inductor abracon smd shielded +0 +2 +2 +Inductor_SMD +L_Bourns-SRN1060 +Bourns SRN1060 series SMD inductor https://www.bourns.com/docs/Product-Datasheets/SRN1060.pdf +Bourns SRN1060 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRN4018 +Bourns SRN4018 series SMD inductor, https://www.bourns.com/docs/Product-Datasheets/SRN4018.pdf +Bourns SRN4018 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRN6028 +Bourns SRN6028 series SMD inductor +Bourns SRN6028 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRN8040_8x8.15mm +Bourns SRN8040 series SMD inductor 8x8.15mm, https://www.bourns.com/docs/Product-Datasheets/SRN8040.pdf +Bourns SRN8040 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRR1005 +Bourns SRR1005 series SMD inductor +Bourns SRR1005 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRU1028_10.0x10.0mm +Bourns SRU1028 series SMD inductor, https://www.bourns.com/docs/Product-Datasheets/SRU1028.pdf +Bourns SRU1028 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRU8028_8.0x8.0mm +Bourns SRU8028 series SMD inductor +Bourns SRU8028 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRU8043 +Bourns SRU8043 series SMD inductor +Bourns SRU8043 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SDR1806 +https://www.bourns.com/docs/Product-Datasheets/SDR1806.pdf +Bourns SDR1806 +0 +2 +2 +Inductor_SMD +L_Bourns_SRF1260 +Inductor, Bourns, SRF1260, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://www.bourns.com/docs/Product-Datasheets/SRF1260.pdf) +Inductor Bourns_SRF1260 +0 +4 +4 +Inductor_SMD +L_Bourns_SRN6045TA +http://www.bourns.com/docs/product-datasheets/srn6045ta.pdf +Semi-shielded Power Inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRN8040TA +https://www.bourns.com/docs/product-datasheets/srn8040ta.pdf +Inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRP1245A +Bourns SRP1245A series SMD inductor http://www.bourns.com/docs/Product-Datasheets/SRP1245A.pdf +Bourns SRP1245A SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRP2313AA +Bourns SRR1260 series SMD inductor http://www.bourns.com/docs/product-datasheets/srp2313aa.pdf +Bourns SRR1260 SMD inductor +0 +4 +2 +Inductor_SMD +L_Bourns_SRP5030T +Inductor, Bourns, SRP5030T, 5.7mmx5.2mm (Script generated with StandardBox.py) (https://www.bourns.com/data/global/pdfs/SRP5030T.pdf) +Inductor Bourns_SRP5030T +0 +2 +2 +Inductor_SMD +L_Bourns_SRP7028A_7.3x6.6mm +Shielded Power Inductors (https://www.bourns.com/docs/product-datasheets/srp7028a.pdf) +Shielded Inductors Bourns SMD SRP7028A +0 +2 +2 +Inductor_SMD +L_Bourns_SRR1210A +Bourns SRR1210A series SMD inductor https://www.bourns.com/docs/Product-Datasheets/SRR1210A.pdf +Bourns SRR1210A SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRR1260 +Bourns SRR1260 series SMD inductor http://www.bourns.com/docs/Product-Datasheets/SRR1260.pdf +Bourns SRR1260 SMD inductor +0 +2 +2 +Inductor_SMD +L_Coilcraft_LPS4018 +SMD Inductor Coilcraft LPS4018 https://www.coilcraft.com/pdfs/lps4018.pdf +L Coilcraft LPS4018 +0 +2 +2 +Inductor_SMD +L_Coilcraft_LPS5030 +Shielded Power Inductor SMD, Coilcraft LPS5030, https://www.coilcraft.com/pdfs/lps5030.pdf, StepUp generated footprint +inductor +0 +2 +2 +Inductor_SMD +L_Coilcraft_XAL60xx_6.36x6.56mm +Coilcraft XAL60xx series, https://www.coilcraft.com/pdfs/xal60xx.pdf +L Coilcraft XAL60xx +0 +2 +2 +Inductor_SMD +L_Coilcraft_XAL5030 +L_Coilcraft_XAL5030 +L Coilcraft XAL5030 +0 +2 +2 +Inductor_SMD +L_Coilcraft_XxL4020 +L_Coilcraft_XxL4020 https://www.coilcraft.com/pdfs/xfl4020.pdf +L Coilcraft XxL4020 +0 +2 +2 +Inductor_SMD +L_Coilcraft_XxL4030 +L_Coilcraft_XxL4030 https://www.coilcraft.com/pdfs/xfl4030.pdf +L Coilcraft XxL4030 +0 +2 +2 +Inductor_SMD +L_Coilcraft_XxL4040 +L_Coilcraft_XxL4040 https://www.coilcraft.com/pdfs/xal4000.pdf +L Coilcraft XxL4040 +0 +2 +2 +Inductor_SMD +L_CommonModeChoke_Coilcraft_0603USB +Coilcraft 0603USB Series Common Mode Choke, https://www.coilcraft.com/pdfs/0603usb.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonModeChoke_Coilcraft_0805USB +Coilcraft 0805USB Series Common Mode Choke, https://www.coilcraft.com/pdfs/0805usb.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonModeChoke_Coilcraft_1812CAN +Coilcraft 1812CAN Series Common Mode Choke, https://www.coilcraft.com/pdfs/1812can.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonModeChoke_Wuerth_WE-SL5 +WE-SL5 SMT Common Mode Line Filter, https://www.we-online.de/katalog/en/WE-SL5/, https://www.we-online.de/katalog/datasheet/744272471.pdf +SMT Common Mode Line Filter +0 +4 +4 +Inductor_SMD +L_CommonMode_Delevan_4222 +API Delevan, Surface Mount Common Mode Bead, 4222 4222R, http://www.delevan.com/seriesPDFs/4222.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonMode_Wuerth_WE-SL2 +http://katalog.we-online.de/en/pbs/WE-SL2?sid=5fbec16187#vs_t1:c1_ct:1 +Wuerth WE-SL2 +0 +4 +4 +Inductor_SMD +L_Fastron_PISN +Choke, Drossel, PISN, SMD, Fastron, +Choke Drossel PISN SMD Fastron +0 +2 +2 +Inductor_SMD +L_Fastron_PISN_Handsoldering +Choke, Drossel, PISN, SMD, Fastron, +Choke Drossel PISN SMD Fastron +0 +2 +2 +Inductor_SMD +L_Fastron_PISR +Choke, Drossel, PISR, Fastron, SMD, +Choke Drossel PISR Fastron SMD +0 +2 +2 +Inductor_SMD +L_Fastron_PISR_Handsoldering +Choke, Drossel, PISR, Fastron, SMD, +Choke Drossel PISR Fastron SMD +0 +2 +2 +Inductor_SMD +L_Murata_DEM35xxC +https://www.murata.com/~/media/webrenewal/products/inductor/chip/tokoproducts/wirewoundferritetypeforpl/m_dem3518c.ashx +Inductor SMD DEM35xxC +0 +2 +2 +Inductor_SMD +L_Murata_LQH2MCNxxxx02_2.0x1.6mm +Inductor, Murata, LQH2MCN_02 series, 1.6x2.0x0.9mm (https://search.murata.co.jp/Ceramy/image/img/P02/JELF243A-0053.pdf) +chip coil inductor Murata LQH2MC +0 +2 +2 +Inductor_SMD +L_Murata_LQH55DN_5.7x5.0mm +Inductor, SMD, 5.7x5.0x4.7mm, https://search.murata.co.jp/Ceramy/image/img/P02/JELF243A-0045.pdf +inductor smd +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_1turn_HDM0131A +Neosid, Air-Coil, SML, 1turn, HDM0131A, +Neosid Air-Coil SML 1turn HDM0131A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_2turn_HAM0231A +Neosid, Air-Coil, SML, 2turn, HAM0231A, +Neosid Air-Coil SML 2turn HAM0231A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_2turn_HDM0231A +Neosid, Air-Coil, SML, 2turn, HDM0231A, +Neosid Air-Coil SML 2turn HDM0231A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_3turn_HAM0331A +Neosid, Air-Coil, SML, 2turn, HAM0331A, +Neosid Air-Coil SML 3turn HAM0331A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_3turn_HDM0331A +Neosid, Air-Coil, SML, 3turn, HDM0331A, +Neosid Air-Coil SML 3turn HDM0331A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_4turn_HAM0431A +Neosid, Air-Coil, SML, 4turn, HAM0431A, +Neosid Air-Coil SML 4turn HAM0431A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_4turn_HDM0431A +Neosid, Air-Coil, SML, 4turn, HDM0431A, +Neosid Air-Coil SML 4turn HDM0431A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_5turn_HAM0531A +Neosid, Air-Coil, SML, 5turn, HAM0531A, +Neosid Air-Coil SML 5turn HAM0531A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_5turn_HDM0531A +Neosid, Air-Coil, SML, 5turn, HDM0531A, +Neosid Air-Coil SML 5turn HDM0531A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_6-10turn_HAM0631A-HAM1031A +Neosid, Air-Coil, SML, 6-10turn, HAM0631A-HAM1031A, +Neosid Air-Coil SML 6-10turn HAM0631A-HAM1031A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_6-10turn_HDM0431A-HDM1031A +Neosid, Air-Coil, SML, 6-10turn, HDM0431A-HDM1031A, +Neosid Air-Coil SML 6-10turn HDM0431A-HDM1031A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_6turn_HAM0631A +Neosid, Air-Coil, SML, 6turn, HAM0631A, +Neosid Air-Coil SML 6turn HAM0631A +0 +2 +2 +Inductor_SMD +L_Neosid_MicroCoil_Ms36-L +Neosid, Micro Coil, Inductor, Ms36-L, SMD, Fixed inductor, anti clockwise, https://neosid.de/en/products/inductors/rod-core-chokes/smd-rod-core-chokes/52026/ms-36/7-h?c=94 +Neosid Micro Coil Inductor Ms36-L SMD Fixed inductor anti clockwise +0 +2 +2 +Inductor_SMD +L_Neosid_Ms42 +Neosid, Inductor, SMs42, Fixed inductor, SMD, magneticaly shielded, https://neosid.de/import-data/product-pdf/neoFestind_Ms42.pdf +Neosid Inductor SMs42 Fixed inductor SMD magneticaly shielded +0 +2 +2 +Inductor_SMD +L_Neosid_Ms50 +Neosid, Power Inductor, Ms50, SMD, Fixed inductor, https://neosid.de/import-data/product-pdf/neoFestind_Ms50.pdf +Neosid Power Inductor Ms50 SMD Fixed inductor +0 +2 +2 +Inductor_SMD +L_Neosid_Ms50T +Neosid, Power Inductor, Ms50T, SMD, Fixed inductor, high temperature, https://neosid.de/import-data/product-pdf/neoFestind_Ms50T.pdf +Neosid Power Inductor Ms50T SMD Fixed inductor high temperature +0 +2 +2 +Inductor_SMD +L_Neosid_Ms85 +Neosid, Ms85, Ms85T, SMD Inductor, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms85.pdf +Neosid Ms85 Ms85T SMD Inductor Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms85T +Neosid, Ms85, Ms85T, SMD Inductor, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms85T.pdf +Neosid Ms85 Ms85T SMD Inductor Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms95 +Neosid,Inductor,Ms95, Ms95a, Ms95T, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms95.pdf +NeosidInductorMs95 Ms95a Ms95T Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms95T +Neosid,Inductor,Ms95, Ms95a, Ms95T, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms95T.pdf +NeosidInductorMs95 Ms95a Ms95T Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms95a +Neosid,Inductor,Ms95, Ms95a, Ms95T, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms95a.pdf +NeosidInductorMs95 Ms95a Ms95T Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE95H +Neosid, Inductor,SM-NE95H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE95H.pdf +Neosid Inductor SM-NE95H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE127 +Neosid, Inductor, SM-NE127, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE127.pdf +Neosid Inductor SM-NE127 Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE127_HandSoldering +Neosid, Inductor, SM-NE127, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE127.pdf +Neosid Inductor SM-NE127 Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE150 +Neosid, Inductor, SM-NE150, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE150.pdf +Neosid Inductor SM-NE150 Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC0512H +Neosid, Inductor, PIC0512H, Power Inductor, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC0512H.pdf +Neosid Inductor PIC0512H Power Inductor Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC0602H +Neosid, Power Inductor, SM-PIC0602H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC0602H.pdf +Neosid Power Inductor SM-PIC0602H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC0612H +Neosid, Power Inductor, SM-PIC0612H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC0612H.pdf +Neosid Power Inductor SM-PIC0612H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC1004H +Neosid, Inductor, SM-PIC1004H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC1004H.pdf +Neosid Inductor SM-PIC1004H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SMS-ME3010 +Neosid, Inductor, SMS-ME3010, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_SMSME3010.pdf +Neosid Inductor SMS-ME3010 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMS-ME3015 +Neosid, Power Inductor, SMS-ME3015, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_SMSME3015.pdf +Neosid Power Inductor SMS-ME3015 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs42 +Neosid, Inductor, SMs42, Fixed inductor, SMD, magneticaly shielded, https://neosid.de/import-data/product-pdf/neoFestind_ma_SMs42.pdf +Neosid Inductor SMs42 Fixed inductor SMD magneticaly shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs50 +Neosid, Inductor, SMs50, Fixed inductor, SMD, magneticaly shielded, https://neosid.de/import-data/product-pdf/neoFestind_ma_SMs50.pdf +Neosid Inductor SMs50 Fixed inductor SMD magneticaly shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs85 +Neosid, Inductor, SMs85, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_ma_SMs85.pdf +Neosid Inductor SMs85 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs95_SMs95p +Neosid, Inductor, SMs95, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_SMs95SMs95p.pdf +Neosid Inductor SMs95 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Pulse_PA4320 +Inductor SMD Pulse PA4320 http://productfinder.pulseeng.com/products/datasheets/P787.pdf +Inductor SMD Pulse PA4320 +0 +2 +2 +Inductor_SMD +L_Sagami_CER1242B +Inductor, Sagami, h=4.5mm, http://www.sagami-elec.co.jp/file/CER1242B-CER1257B-CER1277B.pdf +inductor sagami cer12xxb smd +0 +2 +2 +Inductor_SMD +L_Sagami_CER1257B +Inductor, Sagami, h=6.0mm, http://www.sagami-elec.co.jp/file/CER1242B-CER1257B-CER1277B.pdf +inductor sagami cer12xxb smd +0 +2 +2 +Inductor_SMD +L_Sagami_CER1277B +Inductor, Sagami, h=8.0mm, http://www.sagami-elec.co.jp/file/CER1242B-CER1257B-CER1277B.pdf +inductor sagami cer12xxb smd +0 +2 +2 +Inductor_SMD +L_Sagami_CWR1242C +Sagami power inductor, CWR1242C, H=4.5mm (http://www.sagami-elec.co.jp/file/16Car_SMDCwr.pdf) +inductor sagami cwr12xx smd +0 +4 +2 +Inductor_SMD +L_Sagami_CWR1257C +Sagami power inductor, CWR1242C, H=6.0mm (http://www.sagami-elec.co.jp/file/16Car_SMDCwr.pdf) +inductor sagami cwr12xx smd +0 +4 +2 +Inductor_SMD +L_Sagami_CWR1277C +Sagami power inductor, CWR1242C, H=7.7mm (http://www.sagami-elec.co.jp/file/16Car_SMDCwr.pdf) +inductor sagami cwr12xx smd +0 +4 +2 +Inductor_SMD +L_SigTra_SC3316F +http://www.signaltransformer.com/sites/all/pdf/smd/P080_SC3316F.pdf +Choke +0 +2 +2 +Inductor_SMD +L_Sumida_CDMC6D28_7.25x6.5mm +SMD Power Inductor (http://products.sumida.com/products/pdf/CDMC6D28.pdf) +Inductor Sumida SMD CDMC6D28 +0 +2 +2 +Inductor_SMD +L_Sunlord_MWSA0518_5.4x5.2mm +Inductor, Sunlord, MWSA0518, 5.4mmx5.2mm +inductor Sunlord smd +0 +2 +2 +Inductor_SMD +L_TDK_NLV25_2.5x2.0mm +TDK NLV25, 2.5x2.0x1.8mm, https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_standard_nlv25-ef_en.pdf +tdk nlv25 nlcv25 nlfv25 +0 +2 +2 +Inductor_SMD +L_TDK_NLV32_3.2x2.5mm +TDK NLV32, 3.2x2.5x2.2mm, https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_standard_nlv32-ef_en.pdf +tdk nlv32 nlcv32 nlfv32 +0 +2 +2 +Inductor_SMD +L_TDK_SLF6025 +Inductor, TDK, SLF6025, 6.0mmx6.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf6025_en.pdf) +Inductor TDK_SLF6025 +0 +2 +2 +Inductor_SMD +L_TDK_SLF6028 +Inductor, TDK, SLF6028, 6.0mmx6.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf6028_en.pdf) +Inductor TDK_SLF6028 +0 +2 +2 +Inductor_SMD +L_TDK_SLF6045 +Inductor, TDK, SLF6045, 6.0mmx6.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf6045_en.pdf) +Inductor TDK_SLF6045 +0 +2 +2 +Inductor_SMD +L_TDK_SLF7032 +Inductor, TDK, SLF7032, 7.0mmx7.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf7032_en.pdf) +Inductor TDK_SLF7032 +0 +2 +2 +Inductor_SMD +L_TDK_SLF7045 +Inductor, TDK, SLF7045, 7.0mmx7.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf7045_en.pdf) +Inductor TDK_SLF7045 +0 +2 +2 +Inductor_SMD +L_TDK_SLF7055 +Inductor, TDK, SLF7055, 7.0mmx7.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf7055_en.pdf) +Inductor TDK_SLF7055 +0 +2 +2 +Inductor_SMD +L_TDK_SLF10145 +Inductor, TDK, SLF10145, 10.1mmx10.1mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_automotive_power_slf10145-h_en.pdf) +Inductor TDK_SLF10145 +0 +2 +2 +Inductor_SMD +L_TDK_SLF10165 +Inductor, TDK, SLF10165, 10.1mmx10.1mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_power_slf10165_en.pdf) +Inductor TDK_SLF10165 +0 +2 +2 +Inductor_SMD +L_TDK_SLF12555 +Inductor, TDK, SLF12555, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_power_slf12555_en.pdf) +Inductor SLF12555 +0 +2 +2 +Inductor_SMD +L_TDK_SLF12565 +Inductor, TDK, SLF12565, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_automotive_power_slf12565-h_en.pdf) +Inductor SLF12565 +0 +2 +2 +Inductor_SMD +L_TDK_SLF12575 +Inductor, TDK, SLF12575, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_automotive_power_slf12575-h_en.pdf) +Inductor SLF12575 +0 +2 +2 +Inductor_SMD +L_TDK_VLF10040 +Inductor,TDK, TDK-VLP-8040, 8.6mmx8.6mm +inductor TDK VLP smd VLF10040 +0 +2 +2 +Inductor_SMD +L_TDK_VLP8040 +Inductor,TDK, TDK-VLP-8040, 8.6mmx8.6mm +inductor TDK VLP smd VLP8040 +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-1616 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-1616, 1.6mmx1.6mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-2020 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-2020, 2.0mmx2.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-3030 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-3030, 3.0mmx3.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-4040 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-4040, 4.0mmx4.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-5050 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-5050, 5.0mmx5.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-20xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-20xx, 2.0mmx2.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-20xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-20xx, 2.0mmx2.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-24xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-24xx, 2.4mmx2.4mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-24xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-24xx, 2.4mmx2.4mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-30xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-30xx, 3.0mmx3.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-30xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-30xx, 3.0mmx3.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-40xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-40xx, 4.0mmx4.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-40xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-40xx, 4.0mmx4.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-50xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-50xx, 4.9mmx4.9mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-50xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-50xx, 4.9mmx4.9mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-60xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-60xx, 6.0mmx6.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-60xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-60xx, 6.0mmx6.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-80xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-80xx, 8.0mmx8.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-80xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-80xx, 8.0mmx8.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-10050_9.8x10.0mm +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-10050, 9.8mmx10.0mm, https://ds.yuden.co.jp/TYCOMPAS/or/specSheet?pn=NR10050T1R3N +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-10050_9.8x10.0mm_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-10050, 9.8mmx10.0mm, https://ds.yuden.co.jp/TYCOMPAS/or/specSheet?pn=NR10050T1R3N +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_TracoPower_TCK-047_5.2x5.8mm +Inductor, Traco, TCK-047, 5.2x5.8mm, https://www.tracopower.com/products/tck047.pdf +inductor smd traco +0 +2 +2 +Inductor_SMD +L_TracoPower_TCK-141 +Choke, SMD, 4.0x4.0mm 2.1mm height, https://www.tracopower.com/products/tck141.pdf +Choke SMD +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-1212 +Inductor, Vishay, IHLP series, 3.0mmx3.0mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-1616 +Inductor, Vishay, IHLP series, 4.1mmx4.1mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-2020 +Inductor, Vishay, IHLP series, 5.1mmx5.1mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-2525 +Inductor, Vishay, IHLP series, 6.3mmx6.3mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-4040 +Inductor, Vishay, IHLP series, 10.2mmx10.2mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-5050 +Inductor, Vishay, IHLP series, 12.7mmx12.7mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-6767 +Inductor, Vishay, IHLP series, 17.0mmx17.0mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-3825 +Inductor, Vishay, Vishay_IHSM-3825, http://www.vishay.com/docs/34018/ihsm3825.pdf, 11.2mmx6.3mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-4825 +Inductor, Vishay, Vishay_IHSM-4825, http://www.vishay.com/docs/34019/ihsm4825.pdf, 13.7mmx6.3mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-5832 +Inductor, Vishay, Vishay_IHSM-5832, http://www.vishay.com/docs/34020/ihsm5832.pdf, 16.3mmx8.1mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-7832 +Inductor, Vishay, Vishay_IHSM-7832, http://www.vishay.com/docs/34021/ihsm7832.pdf, 19.8mmx8.1mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1030 +Inductor, Wuerth Elektronik, Wuerth_HCI-1030, 10.6mmx10.6mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1040 +Inductor, Wuerth Elektronik, Wuerth_HCI-1040, 10.2mmx10.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1050 +Inductor, Wuerth Elektronik, Wuerth_HCI-1050, 10.2mmx10.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1335 +Inductor, Wuerth Elektronik, Wuerth_HCI-1335, 12.8mmx12.8mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1350 +Inductor, Wuerth Elektronik, Wuerth_HCI-1350, 12.8mmx12.8mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1365 +Inductor, Wuerth Elektronik, Wuerth_HCI-1365, 12.8mmx12.8mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1890 +Inductor, Wuerth Elektronik, Wuerth_HCI-1890, 18.2mmx18.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-2212 +Inductor, Wuerth Elektronik, Wuerth_HCI-2212, 22.5mmx22.0mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-5040 +Inductor, Wuerth Elektronik, Wuerth_HCI-5040, 5.5mmx5.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-7030 +Inductor, Wuerth Elektronik, Wuerth_HCI-7030, 6.9mmx6.9mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-7040 +Inductor, Wuerth Elektronik, Wuerth_HCI-7040, 6.9mmx6.9mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-7050 +Inductor, Wuerth Elektronik, Wuerth_HCI-7050, 6.9mmx6.9mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1050 +Inductor, Wuerth Elektronik, Wuerth_HCM-1050, 10.2mmx7.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1052 +Inductor, Wuerth Elektronik, Wuerth_HCM-1052, 10.5mmx10.3mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1070 +Inductor, Wuerth Elektronik, Wuerth_HCM-1070, 10.1mmx7.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1078 +Inductor, Wuerth Elektronik, Wuerth_HCM-1078, 9.4mmx6.2mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1190 +Inductor, Wuerth Elektronik, Wuerth_HCM-1190, 10.5mmx11.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1240 +Inductor, Wuerth Elektronik, Wuerth_HCM-1240, 10.0mmx11.8mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1350 +Inductor, Wuerth Elektronik, Wuerth_HCM-1350, 13.5mmx13.3mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1390 +Inductor, Wuerth Elektronik, Wuerth_HCM-1390, 12.5mmx13.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-7050 +Inductor, Wuerth Elektronik, Wuerth_HCM-7050, 7.2mmx7.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-7070 +Inductor, Wuerth Elektronik, Wuerth_HCM-7070, 7.4mmx7.2mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-1610 +Inductor, Wuerth Elektronik, Wuerth_MAPI-1610, 1.6mmx1.6mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2010 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2010, 2.0mmx1.6mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2506 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2506, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2508 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2508, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2510 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2510, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2512 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2512, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3010 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3010, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3012 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3012, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3015 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3015, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3020 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3020, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-4020 +Inductor, Wuerth Elektronik, Wuerth_MAPI-4020, 4.0mmx4.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-4030 +Inductor, Wuerth Elektronik, Wuerth_MAPI-4030, 4.0mmx4.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-DD-Typ-L-Typ-XL-Typ-XXL +Shielded Coupled Inductor, Wuerth Elektronik, WE-DD, SMD, Typ L, Typ XL, Typ XXL, https://katalog.we-online.com/pbs/datasheet/744874001.pdf +Choke Coupled Double Inductor SMD Wuerth WE-DD TypL TypXL TypXXL +0 +4 +4 +Inductor_SMD +L_Wuerth_WE-DD-Typ-M-Typ-S +Shielded Coupled Inductor, Wuerth Elektronik, WE-DD, SMD, Typ M, Typ S, https://katalog.we-online.com/pbs/datasheet/744878001.pdf, https://katalog.we-online.de/pbs/datasheet/744877001.pdf +Choke Coupled Double Inductor SMD Wuerth WE-DD TypM TypS +0 +4 +4 +Inductor_SMD +L_Wuerth_WE-GF-1210 +Unshielded Inductor, Wuerth Elektronik, WE-GF, SMD, 1210, https://www.we-online.de/katalog/datasheet/74476401.pdf +Unshielded Inductor WE-GF 1210 Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-7345 +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMD, 7345, https://katalog.we-online.com/pbs/datasheet/744777001.pdf +Choke Shielded Power Inductor WE-PD 7345 Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-LS +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMD, Typ LS, https://katalog.we-online.com/pbs/datasheet/7447715906.pdf +Choke Shielded Power Inductor WE-PD TypLS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-LS_Handsoldering +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMD, Typ LS, Handsoldering, https://katalog.we-online.com/pbs/datasheet/7447715906.pdf +Choke Shielded Power Inductor WE-PD TypLS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-M-Typ-S +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMT, Typ M, Typ S, https://katalog.we-online.com/pbs/datasheet/744778005.pdf +Choke Shielded Power Inductor WE-PD TypM TypS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-M-Typ-S_Handsoldering +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMT, Typ M, Typ S, Handsoldering, https://katalog.we-online.com/pbs/datasheet/744778005.pdf +Choke Shielded Power Inductor WE-PD TypM TypS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD2-Typ-L +Power Inductor, Wuerth Elektronik, WE-PD2, SMD, Typ L, , https://katalog.we-online.com/pbs/datasheet/74477510.pdf +Choke Power Inductor WE-PD2 TypL Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD2-Typ-MS +Power Inductor, Wuerth Elektronik, WE-PD2, SMD, Typ MS, https://katalog.we-online.com/pbs/datasheet/744774022.pdf +Choke Power Inductor WE-PD2 TypMS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD2-Typ-XL +Power Inductor, Wuerth Elektronik, WE-PD2, SMT, Typ XL, https://katalog.we-online.com/pbs/datasheet/744776012.pdf +Choke Power Inductor WE-PD2 TypXL Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD4-Typ-X +Power Inductor, Wuerth Elektronik, WE-PD4, SMT, Typ X, https://katalog.we-online.de/pbs/datasheet/74458001.pdf +Choke Power Inductor WE-PD4 TypX Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PDF +Shielded Power Inductor, Wuerth Elektronik, WE-PDF, SMD, https://katalog.we-online.de/pbs/datasheet/7447797022.pdf +Choke Shielded Power Inductor WE-PDF Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PDF_Handsoldering +Shielded Power Inductor, Wuerth Elektronik, WE-PDF, SMD, Handsoldering, https://katalog.we-online.de/pbs/datasheet/7447797022.pdf +Choke Shielded Power Inductor WE-PDF Wuerth Handsoldering +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-TPC-3816 +L_Wuerth_WE-TPC-3816 StepUp generated footprint, http://katalog.we-online.de/pbs/datasheet/7440310047.pdf +wurth wuerth smd inductor +0 +2 +2 +Inductor_THT +Choke_EPCOS_B82722A +Current-Compensated Ring Core Double Chokes, EPCOS, B82722A, 22.3mmx22.7mm, https://en.tdk.eu/inf/30/db/ind_2008/b82722a_j.pdf +chokes epcos tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN102-04-14.0x14.0mm +Current-compensated Chokes, Schaffner, RN102-04, 14.0mmx14.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN112-04-17.7x17.1mm +Current-compensated Chokes, Schaffner, RN112-04, 17.7mmx17.1mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN114-04-22.5x21.5mm +Current-compensated Chokes, Schaffner, RN114-04, 22.5mmx21.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN116-04-22.5x21.5mm +Current-compensated Chokes, Schaffner, RN116-04, 22.5mmx21.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN122-04-28.0x27.0mm +Current-compensated Chokes, Schaffner, RN122-04, 28.0mmx27.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN142-04-33.1x32.5mm +Current-compensated Chokes, Schaffner, RN142-04, 33.1mmx32.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN143-04-33.1x32.5mm +Current-compensated Chokes, Schaffner, RN143-04, 33.1mmx32.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN152-04-43.0x41.8mm +Current-compensated Chokes, Schaffner, RN152-04, 43.0mmx41.8mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN202-04-8.8x18.2mm +Current-compensated Chokes, Schaffner, RN202-04, 8.8mmx18.2mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN204-04-9.0x14.0mm +Current-compensated Chokes, Schaffner, RN204-04, 9.0mmx14.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN212-04-12.5x18.0mm +Current-compensated Chokes, Schaffner, RN212-04, 12.5mmx18.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN214-04-15.5x23.0mm +Current-compensated Chokes, Schaffner, RN214-04, 15.5mmx23.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN216-04-15.5x23.0mm +Current-compensated Chokes, Schaffner, RN216-04, 15.5mmx23.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN218-04-12.5x18.0mm +Current-compensated Chokes, Schaffner, RN218-04, 12.5mmx18.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN222-04-18.0x31.0mm +Current-compensated Chokes, Schaffner, RN222-04, 18.0mmx31.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN232-04-18.0x31.0mm +Current-compensated Chokes, Schaffner, RN232-04, 18.0mmx31.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN242-04-18.0x31.0mm +Current-compensated Chokes, Schaffner, RN242-04, 18.0mmx31.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +L_Axial_L5.0mm_D3.6mm_P10.00mm_Horizontal_Murata_BL01RN1A2A2 +Inductor, Murata BL01RN1A2A2, Axial, Horizontal, pin pitch=10.00mm, length*diameter=5*3.6mm, https://www.murata.com/en-global/products/productdetail?partno=BL01RN1A2A2%23 +inductor axial horizontal +0 +2 +2 +Inductor_THT +L_Axial_L5.3mm_D2.2mm_P2.54mm_Vertical_Vishay_IM-1 +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.3*2.2mm^2, Vishay, IM-1, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Vertical pin pitch 2.54mm length 5.3mm diameter 2.2mm Vishay IM-1 +0 +2 +2 +Inductor_THT +L_Axial_L5.3mm_D2.2mm_P7.62mm_Horizontal_Vishay_IM-1 +Inductor, Axial series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=5.3*2.2mm^2, Vishay, IM-1, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Horizontal pin pitch 7.62mm length 5.3mm diameter 2.2mm Vishay IM-1 +0 +2 +2 +Inductor_THT +L_Axial_L5.3mm_D2.2mm_P10.16mm_Horizontal_Vishay_IM-1 +Inductor, Axial series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=5.3*2.2mm^2, Vishay, IM-1, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Horizontal pin pitch 10.16mm length 5.3mm diameter 2.2mm Vishay IM-1 +0 +2 +2 +Inductor_THT +L_Axial_L6.6mm_D2.7mm_P2.54mm_Vertical_Vishay_IM-2 +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=6.6*2.7mm^2, Vishay, IM-2, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Vertical pin pitch 2.54mm length 6.6mm diameter 2.7mm Vishay IM-2 +0 +2 +2 +Inductor_THT +L_Axial_L6.6mm_D2.7mm_P10.16mm_Horizontal_Vishay_IM-2 +Inductor, Axial series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=6.6*2.7mm^2, Vishay, IM-2, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Horizontal pin pitch 10.16mm length 6.6mm diameter 2.7mm Vishay IM-2 +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P2.54mm_Vertical_Fastron_MICC +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 2.54mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P5.08mm_Vertical_Fastron_MICC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P10.16mm_Horizontal_Fastron_MICC +Inductor, Axial series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 10.16mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P12.70mm_Horizontal_Fastron_MICC +Inductor, Axial series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 12.7mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P2.54mm_Vertical_Fastron_SMCC +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Vertical pin pitch 2.54mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P5.08mm_Vertical_Fastron_SMCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P12.70mm_Horizontal_Fastron_SMCC +Inductor, Axial series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Horizontal pin pitch 12.7mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P15.24mm_Horizontal_Fastron_SMCC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L11.0mm_D4.5mm_P5.08mm_Vertical_Fastron_MECC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=11*4.5mm^2, Fastron, MECC, http://www.fastrongroup.com/image-show/21/MECC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 11mm diameter 4.5mm Fastron MECC +0 +2 +2 +Inductor_THT +L_Axial_L11.0mm_D4.5mm_P7.62mm_Vertical_Fastron_MECC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=11*4.5mm^2, Fastron, MECC, http://www.fastrongroup.com/image-show/21/MECC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 11mm diameter 4.5mm Fastron MECC +0 +2 +2 +Inductor_THT +L_Axial_L11.0mm_D4.5mm_P15.24mm_Horizontal_Fastron_MECC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=11*4.5mm^2, Fastron, MECC, http://www.fastrongroup.com/image-show/21/MECC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 11mm diameter 4.5mm Fastron MECC +0 +2 +2 +Inductor_THT +L_Axial_L12.0mm_D5.0mm_P5.08mm_Vertical_Fastron_MISC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=12*5mm^2, Fastron, MISC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MISC.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 12mm diameter 5mm Fastron MISC +0 +2 +2 +Inductor_THT +L_Axial_L12.0mm_D5.0mm_P7.62mm_Vertical_Fastron_MISC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=12*5mm^2, Fastron, MISC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MISC.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 12mm diameter 5mm Fastron MISC +0 +2 +2 +Inductor_THT +L_Axial_L12.0mm_D5.0mm_P15.24mm_Horizontal_Fastron_MISC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=12*5mm^2, Fastron, MISC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MISC.pdf +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 12mm diameter 5mm Fastron MISC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P5.08mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P7.62mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P20.32mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P25.40mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L13.0mm_D4.5mm_P5.08mm_Vertical_Fastron_HCCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=13*4.5mm^2, Fastron, HCCC, http://www.fastrongroup.com/image-show/19/HCCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 13mm diameter 4.5mm Fastron HCCC +0 +2 +2 +Inductor_THT +L_Axial_L13.0mm_D4.5mm_P7.62mm_Vertical_Fastron_HCCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=13*4.5mm^2, Fastron, HCCC, http://www.fastrongroup.com/image-show/19/HCCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 13mm diameter 4.5mm Fastron HCCC +0 +2 +2 +Inductor_THT +L_Axial_L13.0mm_D4.5mm_P15.24mm_Horizontal_Fastron_HCCC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=13*4.5mm^2, Fastron, HCCC, http://www.fastrongroup.com/image-show/19/HCCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 13mm diameter 4.5mm Fastron HCCC +0 +2 +2 +Inductor_THT +L_Axial_L14.0mm_D4.5mm_P5.08mm_Vertical_Fastron_LACC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=14*4.5mm^2, Fastron, LACC, http://www.fastrongroup.com/image-show/20/LACC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 14mm diameter 4.5mm Fastron LACC +0 +2 +2 +Inductor_THT +L_Axial_L14.0mm_D4.5mm_P7.62mm_Vertical_Fastron_LACC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=14*4.5mm^2, Fastron, LACC, http://www.fastrongroup.com/image-show/20/LACC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 14mm diameter 4.5mm Fastron LACC +0 +2 +2 +Inductor_THT +L_Axial_L14.0mm_D4.5mm_P15.24mm_Horizontal_Fastron_LACC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=14*4.5mm^2, Fastron, LACC, http://www.fastrongroup.com/image-show/20/LACC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 14mm diameter 4.5mm Fastron LACC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P5.08mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P7.62mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P20.32mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P25.40mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P5.08mm_Vertical_Fastron_VHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P7.62mm_Vertical_Fastron_VHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P20.32mm_Horizontal_Fastron_VHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P25.40mm_Horizontal_Fastron_VHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P5.08mm_Vertical_Fastron_XHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P7.62mm_Vertical_Fastron_XHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P20.32mm_Horizontal_Fastron_XHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P25.40mm_Horizontal_Fastron_XHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D9.5mm_P5.08mm_Vertical_Vishay_IM-10-37 +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=16*9.5mm^2, Vishay, IM-10-37, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 16mm diameter 9.5mm Vishay IM-10-37 +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D9.5mm_P20.32mm_Horizontal_Vishay_IM-10-37 +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=16*9.5mm^2, Vishay, IM-10-37, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 16mm diameter 9.5mm Vishay IM-10-37 +0 +2 +2 +Inductor_THT +L_Axial_L17.5mm_D12.0mm_P7.62mm_Vertical_Vishay_IM-10-46 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=17.5*12mm^2, Vishay, IM-10-46, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 17.5mm diameter 12mm Vishay IM-10-46 +0 +2 +2 +Inductor_THT +L_Axial_L17.5mm_D12.0mm_P20.32mm_Horizontal_Vishay_IM-10-46 +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=17.5*12mm^2, Vishay, IM-10-46, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 17.5mm diameter 12mm Vishay IM-10-46 +0 +2 +2 +Inductor_THT +L_Axial_L20.0mm_D8.0mm_P5.08mm_Vertical +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=20*8mm^2 +Inductor Axial series Axial Vertical pin pitch 5.08mm length 20mm diameter 8mm +0 +2 +2 +Inductor_THT +L_Axial_L20.0mm_D8.0mm_P7.62mm_Vertical +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=20*8mm^2 +Inductor Axial series Axial Vertical pin pitch 7.62mm length 20mm diameter 8mm +0 +2 +2 +Inductor_THT +L_Axial_L20.0mm_D8.0mm_P25.40mm_Horizontal +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=20*8mm^2 +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 20mm diameter 8mm +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.1mm_P7.62mm_Vertical_Vishay_IHA-101 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=20.32*12.07mm^2, Vishay, IHA-101, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 20.32mm diameter 12.07mm Vishay IHA-101 +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.1mm_P28.50mm_Horizontal_Vishay_IHA-101 +Inductor, Axial series, Axial, Horizontal, pin pitch=28.5mm, , length*diameter=20.32*12.07mm^2, Vishay, IHA-101, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 28.5mm length 20.32mm diameter 12.07mm Vishay IHA-101 +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.7mm_P7.62mm_Vertical_Vishay_IHA-201 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=20.32*12.7mm^2, Vishay, IHA-201, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 20.32mm diameter 12.7mm Vishay IHA-201 +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.7mm_P25.40mm_Horizontal_Vishay_IHA-201 +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=20.32*12.7mm^2, Vishay, IHA-201, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 20.32mm diameter 12.7mm Vishay IHA-201 +0 +2 +2 +Inductor_THT +L_Axial_L23.4mm_D12.7mm_P7.62mm_Vertical_Vishay_IHA-203 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=23.37*12.7mm^2, Vishay, IHA-203, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 23.37mm diameter 12.7mm Vishay IHA-203 +0 +2 +2 +Inductor_THT +L_Axial_L23.4mm_D12.7mm_P32.00mm_Horizontal_Vishay_IHA-203 +Inductor, Axial series, Axial, Horizontal, pin pitch=32mm, , length*diameter=23.37*12.7mm^2, Vishay, IHA-203, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 32mm length 23.37mm diameter 12.7mm Vishay IHA-203 +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.1mm_P5.08mm_Vertical_Vishay_IM-10-28 +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=24*7.1mm^2, Vishay, IM-10-28, http://www.vishay.com/docs/34035/im10.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 24mm diameter 7.1mm Vishay IM-10-28 +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.1mm_P30.48mm_Horizontal_Vishay_IM-10-28 +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=24*7.1mm^2, Vishay, IM-10-28, http://www.vishay.com/docs/34035/im10.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 24mm diameter 7.1mm Vishay IM-10-28 +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.5mm_P5.08mm_Vertical_Fastron_MESC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=24*7.5mm^2, Fastron, MESC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MESC.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 24mm diameter 7.5mm Fastron MESC +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.5mm_P7.62mm_Vertical_Fastron_MESC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=24*7.5mm^2, Fastron, MESC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MESC.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 24mm diameter 7.5mm Fastron MESC +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.5mm_P27.94mm_Horizontal_Fastron_MESC +Inductor, Axial series, Axial, Horizontal, pin pitch=27.94mm, , length*diameter=24*7.5mm^2, Fastron, MESC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MESC.pdf +Inductor Axial series Axial Horizontal pin pitch 27.94mm length 24mm diameter 7.5mm Fastron MESC +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D9.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=26*9mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 26mm diameter 9mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D9.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26*9mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26mm diameter 9mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D9.0mm_P30.48mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=26*9mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 26mm diameter 9mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D10.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=26*10mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 26mm diameter 10mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D10.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26*10mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26mm diameter 10mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D10.0mm_P30.48mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=26*10mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 26mm diameter 10mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D11.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=26*11mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 26mm diameter 11mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D11.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26*11mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26mm diameter 11mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D11.0mm_P30.48mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=26*11mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 26mm diameter 11mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D12.1mm_P7.62mm_Vertical_Vishay_IHA-103 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26.67*12.07mm^2, Vishay, IHA-103, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26.67mm diameter 12.07mm Vishay IHA-103 +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D12.1mm_P35.00mm_Horizontal_Vishay_IHA-103 +Inductor, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=26.67*12.07mm^2, Vishay, IHA-103, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 35mm length 26.67mm diameter 12.07mm Vishay IHA-103 +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D14.0mm_P7.62mm_Vertical_Vishay_IHA-104 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26.67*13.97mm^2, Vishay, IHA-104, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26.67mm diameter 13.97mm Vishay IHA-104 +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D14.0mm_P35.00mm_Horizontal_Vishay_IHA-104 +Inductor, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=26.67*13.97mm^2, Vishay, IHA-104, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 35mm length 26.67mm diameter 13.97mm Vishay IHA-104 +0 +2 +2 +Inductor_THT +L_Axial_L29.9mm_D14.0mm_P7.62mm_Vertical_Vishay_IHA-105 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=29.85*13.97mm^2, Vishay, IHA-105, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 29.85mm diameter 13.97mm Vishay IHA-105 +0 +2 +2 +Inductor_THT +L_Axial_L29.9mm_D14.0mm_P38.00mm_Horizontal_Vishay_IHA-105 +Inductor, Axial series, Axial, Horizontal, pin pitch=38mm, , length*diameter=29.85*13.97mm^2, Vishay, IHA-105, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 38mm length 29.85mm diameter 13.97mm Vishay IHA-105 +0 +2 +2 +Inductor_THT +L_Axial_L30.0mm_D8.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=30*8mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 30mm diameter 8mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L30.0mm_D8.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=30*8mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 30mm diameter 8mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L30.0mm_D8.0mm_P35.56mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=35.56mm, , length*diameter=30*8mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 35.56mm length 30mm diameter 8mm Fastron 77A +0 +2 +2 +Inductor_THT +L_CommonMode_Toroid_Vertical_L19.3mm_W10.8mm_Px6.35mm_Py15.24mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=6.35*15.24mm^2, , length*width=19.304*10.795mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 6.35*15.24mm^2 length 19.304mm width 10.795mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L21.0mm_W10.0mm_Px5.08mm_Py12.70mm_muRATA_5100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=5.08*12.70mm^2, , length*width=21*10mm^2, muRATA, 5100, http://www.murata-ps.com/data/magnetics/kmp_5100.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 5.08*12.70mm^2 length 21mm width 10mm muRATA 5100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L24.0mm_W16.3mm_Px10.16mm_Py20.32mm_muRATA_5200 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=10.16*20.32mm^2, , length*width=24*16.3mm^2, muRATA, 5200, http://www.murata-ps.com/data/magnetics/kmp_5200.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 10.16*20.32mm^2 length 24mm width 16.3mm muRATA 5200 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L30.5mm_W15.2mm_Px10.16mm_Py20.32mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=10.16*20.32mm^2, , length*width=30.479999999999997*15.239999999999998mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 10.16*20.32mm^2 length 30.479999999999997mm width 15.239999999999998mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L34.3mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=34.29*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 34.29mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L36.8mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=36.83*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 36.83mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L38.1mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=38.099999999999994*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 38.099999999999994mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L39.4mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=39.37*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 39.37mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L41.9mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=41.91*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 41.91mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L43.2mm_W22.9mm_Px17.78mm_Py30.48mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=17.78*30.48mm^2, , length*width=43.18*22.86mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 17.78*30.48mm^2 length 43.18mm width 22.86mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-L +Wuerth, WE-CMB, Bauform L, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-M +Wuerth, WE-CMB, Bauform M, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-S +Wuerth, WE-CMB, Bauform S, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-XL +Wuerth, WE-CMB, Bauform XL, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-XS +Wuerth, WE-CMB, Bauform XS, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-XXL +Wuerth, WE-CMB, Bauform XXL, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM120 +Lodestone Pacific, 30.48mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM160 +Lodestone Pacific, 40.64mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM254 +Lodestone Pacific, 64.51mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM280 +Lodestone Pacific, 71.12mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM950-6 +Lodestone Pacific, vertical toroid mount, 11x19mm, 6 pins, http://www.lodestonepacific.com/CatKpdf/VTM950-6.pdf +vertical inductor toroid mount +0 +6 +6 +Inductor_THT +L_Radial_D6.0mm_P4.00mm +Inductor, Radial series, Radial, pin pitch=4.00mm, , diameter=6.0mm, http://www.abracon.com/Magnetics/radial/AIUR-07.pdf +Inductor Radial series Radial pin pitch 4.00mm diameter 6.0mm +0 +2 +2 +Inductor_THT +L_Radial_D7.0mm_P3.00mm +Inductor, Radial series, Radial, pin pitch=3.00mm, , diameter=7mm, http://www.abracon.com/Magnetics/radial/AIUR-16.pdf +Inductor Radial series Radial pin pitch 3.00mm diameter 7mm +0 +2 +2 +Inductor_THT +L_Radial_D7.2mm_P3.00mm_MuRATA_1700 +Inductor, Radial series, Radial, pin pitch=3.00mm, , diameter=7.2mm, MuRATA, 1700, http://www.murata-ps.com/data/magnetics/kmp_1700.pdf +Inductor Radial series Radial pin pitch 3.00mm diameter 7.2mm MuRATA 1700 +0 +2 +2 +Inductor_THT +L_Radial_D7.5mm_P3.50mm_Fastron_07P +Inductor, Radial series, Radial, pin pitch=3.50mm, , diameter=7.5mm, Fastron, 07P, http://www.fastrongroup.com/image-show/39/07P.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 3.50mm diameter 7.5mm Fastron 07P +0 +2 +2 +Inductor_THT +L_Radial_D7.5mm_P5.00mm_Fastron_07P +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=7.5mm, Fastron, 07P, http://www.fastrongroup.com/image-show/39/07P.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 7.5mm Fastron 07P +0 +2 +2 +Inductor_THT +L_Radial_D7.8mm_P5.00mm_Fastron_07HCP +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=7.8mm, Fastron, 07HCP, http://www.abracon.com/Magnetics/radial/AISR875.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 7.8mm Fastron 07HCP +0 +2 +2 +Inductor_THT +L_Radial_D8.7mm_P5.00mm_Fastron_07HCP +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=8.7mm, Fastron, 07HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_07HCP.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 8.7mm Fastron 07HCP +0 +2 +2 +Inductor_THT +L_Radial_D9.5mm_P5.00mm_Fastron_07HVP +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=9.5mm, Fastron, 07HVP, http://www.fastrongroup.com/image-show/107/07HVP%2007HVP_T.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 9.5mm Fastron 07HVP +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Fastron_07M +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Fastron, 07M, http://www.fastrongroup.com/image-show/37/07M.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 10mm Fastron 07M +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Fastron_07P +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Fastron, 07P, http://www.fastrongroup.com/image-show/37/07M.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 10mm Fastron 07P +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Neosid_SD12_style3 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10.0mm, Neosid, SD12, style3, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 10.0mm Neosid SD12 style3 +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Neosid_SD12k_style3 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10.0mm, Neosid, SD12k, style3, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12k.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 10.0mm Neosid SD12k style3 +0 +2 +2 +Inductor_THT +L_Radial_D10.5mm_P4.00x5.00mm_Murata_1200RS +Inductor, Radial, Pitch=4.00x5.00mm, Diameter=10.5mm, Murata 1200RS, http://www.murata-ps.com/data/magnetics/kmp_1200rs.pdf +Inductor Radial Murata 1200RS +0 +4 +2 +Inductor_THT +L_Radial_D10.5mm_P5.00mm_Abacron_AISR-01 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10.5mm, Abacron, AISR-01, http://www.abracon.com/Magnetics/radial/AISR-01.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 10.5mm Abacron AISR-01 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P5.00mm_Fastron_11P +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=12.0mm, Fastron, 11P, http://cdn-reichelt.de/documents/datenblatt/B400/DS_11P.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 12.0mm Fastron 11P +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P5.00mm_Neosid_SD12_style2 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=12.0mm, Neosid, SD12, style2, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 12.0mm Neosid SD12 style2 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P5.00mm_Neosid_SD12k_style2 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=12.0mm, Neosid, SD12k, style2, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12k.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 12.0mm Neosid SD12k style2 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P6.00mm_MuRATA_1900R +Inductor, Radial series, Radial, pin pitch=6.00mm, , diameter=12.0mm, MuRATA, 1900R, http://www.murata-ps.com/data/magnetics/kmp_1900r.pdf +Inductor Radial series Radial pin pitch 6.00mm diameter 12.0mm MuRATA 1900R +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P10.00mm_Neosid_SD12_style1 +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=12.0mm, Neosid, SD12, style1, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 12.0mm Neosid SD12 style1 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P10.00mm_Neosid_SD12k_style1 +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=12.0mm, Neosid, SD12k, style1, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12k.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 12.0mm Neosid SD12k style1 +0 +2 +2 +Inductor_THT +L_Radial_D12.5mm_P7.00mm_Fastron_09HCP +Inductor, Radial series, Radial, pin pitch=7.00mm, , diameter=12.5mm, Fastron, 09HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_09HCP.pdf +Inductor Radial series Radial pin pitch 7.00mm diameter 12.5mm Fastron 09HCP +0 +2 +2 +Inductor_THT +L_Radial_D12.5mm_P9.00mm_Fastron_09HCP +Inductor, Radial series, Radial, pin pitch=9.00mm, , diameter=12.5mm, Fastron, 09HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_09HCP.pdf +Inductor Radial series Radial pin pitch 9.00mm diameter 12.5mm Fastron 09HCP +0 +2 +2 +Inductor_THT +L_Radial_D13.5mm_P7.00mm_Fastron_09HCP +Inductor, Radial series, Radial, pin pitch=7.00mm, , diameter=13.5mm, Fastron, 09HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_09HCP.pdf +Inductor Radial series Radial pin pitch 7.00mm diameter 13.5mm Fastron 09HCP +0 +2 +2 +Inductor_THT +L_Radial_D14.2mm_P10.00mm_Neosid_SD14 +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=14.2mm, Neosid, SD14, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd14.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 14.2mm Neosid SD14 +0 +2 +2 +Inductor_THT +L_Radial_D16.8mm_P11.43mm_Vishay_IHB-1 +Inductor, Radial series, Radial, pin pitch=11.43mm, , diameter=16.8mm, Vishay, IHB-1, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 11.43mm diameter 16.8mm Vishay IHB-1 +0 +2 +2 +Inductor_THT +L_Radial_D16.8mm_P12.07mm_Vishay_IHB-1 +Inductor, Radial series, Radial, pin pitch=12.07mm, , diameter=16.8mm, Vishay, IHB-1, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 12.07mm diameter 16.8mm Vishay IHB-1 +0 +2 +2 +Inductor_THT +L_Radial_D16.8mm_P12.70mm_Vishay_IHB-1 +Inductor, Radial series, Radial, pin pitch=12.70mm, , diameter=16.8mm, Vishay, IHB-1, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 12.70mm diameter 16.8mm Vishay IHB-1 +0 +2 +2 +Inductor_THT +L_Radial_D18.0mm_P10.00mm +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=18mm, http://www.abracon.com/Magnetics/radial/AIUR-15.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 18mm +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P14.61mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=14.61mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 14.61mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P15.00mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=15.00mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 15.00mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P15.24mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=15.24mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 15.24mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P15.75mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=15.75mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 15.75mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P19.00mm +Inductor, Radial series, Radial, pin pitch=19.00mm, , diameter=21mm, http://www.abracon.com/Magnetics/radial/AIRD02.pdf +Inductor Radial series Radial pin pitch 19.00mm diameter 21mm +0 +2 +2 +Inductor_THT +L_Radial_D24.0mm_P24.00mm +Inductor, Radial series, Radial, pin pitch=24.00mm, , diameter=24mm +Inductor Radial series Radial pin pitch 24.00mm diameter 24mm +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P22.90mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=22.90mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 22.90mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.10mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.10mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.10mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.40mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.40mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.40mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.70mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.70mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.70mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.90mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.90mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.90mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D27.9mm_P18.29mm_Vishay_IHB-3 +Inductor, Radial series, Radial, pin pitch=18.29mm, , diameter=27.9mm, Vishay, IHB-3, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 18.29mm diameter 27.9mm Vishay IHB-3 +0 +2 +2 +Inductor_THT +L_Radial_D27.9mm_P19.05mm_Vishay_IHB-3 +Inductor, Radial series, Radial, pin pitch=19.05mm, , diameter=27.9mm, Vishay, IHB-3, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 19.05mm diameter 27.9mm Vishay IHB-3 +0 +2 +2 +Inductor_THT +L_Radial_D27.9mm_P20.07mm_Vishay_IHB-3 +Inductor, Radial series, Radial, pin pitch=20.07mm, , diameter=27.9mm, Vishay, IHB-3, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 20.07mm diameter 27.9mm Vishay IHB-3 +0 +2 +2 +Inductor_THT +L_Radial_D28.0mm_P29.20mm +Inductor, Radial series, Radial, pin pitch=29.20mm, , diameter=28mm +Inductor Radial series Radial pin pitch 29.20mm diameter 28mm +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P28.30mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=28.30mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 28.30mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P28.50mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=28.50mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 28.50mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P28.80mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=28.80mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 28.80mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P29.00mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=29.00mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 29.00mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P29.30mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=29.30mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 29.30mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P26.16mm_Vishay_IHB-5 +Inductor, Radial series, Radial, pin pitch=26.16mm, , diameter=40.64mm, Vishay, IHB-5, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 26.16mm diameter 40.64mm Vishay IHB-5 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P27.18mm_Vishay_IHB-4 +Inductor, Radial series, Radial, pin pitch=27.18mm, , diameter=40.64mm, Vishay, IHB-4, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 27.18mm diameter 40.64mm Vishay IHB-4 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P27.94mm_Vishay_IHB-4 +Inductor, Radial series, Radial, pin pitch=27.94mm, , diameter=40.64mm, Vishay, IHB-4, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 27.94mm diameter 40.64mm Vishay IHB-4 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P27.94mm_Vishay_IHB-5 +Inductor, Radial series, Radial, pin pitch=27.94mm, , diameter=40.64mm, Vishay, IHB-5, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 27.94mm diameter 40.64mm Vishay IHB-5 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P28.70mm_Vishay_IHB-5 +Inductor, Radial series, Radial, pin pitch=28.70mm, , diameter=40.64mm, Vishay, IHB-5, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 28.70mm diameter 40.64mm Vishay IHB-5 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P33.27mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=33.27mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 33.27mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P34.29mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=34.29mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 34.29mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P35.81mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=35.81mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 35.81mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P36.32mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=36.32mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 36.32mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P38.86mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=38.86mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 38.86mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_L7.5mm_W4.6mm_P5.00mm_Neosid_SD75 +Inductor, Radial series, Radial, pin pitch=5.00mm, , length*width=7.5*4.6mm^2, Neosid, SD75, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd75.pdf +Inductor Radial series Radial pin pitch 5.00mm length 7.5mm width 4.6mm Neosid SD75 +0 +2 +2 +Inductor_THT +L_Radial_L8.0mm_W8.0mm_P5.00mm_Neosid_NE-CPB-07E +Inductor, Radial series, Radial, pin pitch=5.00mm, , length*width=8*8mm^2, Neosid, NE-CPB-07E, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB07E.pdf +Inductor Radial series Radial pin pitch 5.00mm length 8mm width 8mm Neosid NE-CPB-07E +0 +2 +2 +Inductor_THT +L_Radial_L8.0mm_W8.0mm_P5.00mm_Neosid_SD8 +Inductor, Radial series, Radial, pin pitch=5.00mm, , length*width=8*8mm^2, Neosid, SD8, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd8.pdf +Inductor Radial series Radial pin pitch 5.00mm length 8mm width 8mm Neosid SD8 +0 +2 +2 +Inductor_THT +L_Radial_L9.1mm_W9.1mm_Px6.35mm_Py6.35mm_Pulse_LP-25 +Inductor, Radial series, Radial, pin pitch=6.35*6.35mm^2, , length*width=9.14*9.14mm^2, Pulse, LP-25, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 6.35*6.35mm^2 length 9.14mm width 9.14mm Pulse LP-25 +0 +2 +2 +Inductor_THT +L_Radial_L10.2mm_W10.2mm_Px7.62mm_Py7.62mm_Pulse_LP-30 +Inductor, Radial series, Radial, pin pitch=7.62*7.62mm^2, , length*width=10.16*10.16mm^2, Pulse, LP-30, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 7.62*7.62mm^2 length 10.16mm width 10.16mm Pulse LP-30 +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.3mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.3mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.3mm +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.5mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.5mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.5mm +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.7mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.7mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.7mm +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.8mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.8mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.8mm +0 +2 +2 +Inductor_THT +L_Radial_L12.6mm_W12.6mm_Px9.52mm_Py9.52mm_Pulse_LP-37 +Inductor, Radial series, Radial, pin pitch=9.52*9.52mm^2, , length*width=12.57*12.57mm^2, Pulse, LP-37, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 9.52*9.52mm^2 length 12.57mm width 12.57mm Pulse LP-37 +0 +2 +2 +Inductor_THT +L_Radial_L16.1mm_W16.1mm_Px7.62mm_Py12.70mm_Pulse_LP-44 +Inductor, Radial series, Radial, pin pitch=7.62*12.70mm^2, , length*width=16.13*16.13mm^2, Pulse, LP-44, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 7.62*12.70mm^2 length 16.13mm width 16.13mm Pulse LP-44 +0 +2 +2 +Inductor_THT +L_SELF1408 +Self Ferrite 14 - 08 +SELF +0 +7 +3 +Inductor_THT +L_SELF1418 +Self Ferrite 14 - 18 +SELF +0 +10 +4 +Inductor_THT +L_Toroid_Horizontal_D3.2mm_P6.40mm_Diameter3-5mm_Amidon-T12 +L_Toroid, Horizontal series, Radial, pin pitch=6.40mm, , diameter=3.175mm, Diameter3-5mm, Amidon-T12 +L_Toroid Horizontal series Radial pin pitch 6.40mm diameter 3.175mm Diameter3-5mm Amidon-T12 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D4.1mm_P8.00mm_Diameter4-5mm_Amidon-T16 +L_Toroid, Horizontal series, Radial, pin pitch=8.00mm, , diameter=4.064mm, Diameter4-5mm, Amidon-T16 +L_Toroid Horizontal series Radial pin pitch 8.00mm diameter 4.064mm Diameter4-5mm Amidon-T16 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D5.1mm_P9.00mm_Diameter6-5mm_Amidon-T20 +L_Toroid, Horizontal series, Radial, pin pitch=9.00mm, , diameter=5.08mm, Diameter6-5mm, Amidon-T20 +L_Toroid Horizontal series Radial pin pitch 9.00mm diameter 5.08mm Diameter6-5mm Amidon-T20 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D6.5mm_P10.00mm_Diameter7-5mm_Amidon-T25 +L_Toroid, Horizontal series, Radial, pin pitch=10.00mm, , diameter=6.476999999999999mm, Diameter7-5mm, Amidon-T25 +L_Toroid Horizontal series Radial pin pitch 10.00mm diameter 6.476999999999999mm Diameter7-5mm Amidon-T25 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D7.8mm_P13.00mm_Diameter9-5mm_Amidon-T30 +L_Toroid, Horizontal series, Radial, pin pitch=13.00mm, , diameter=7.7978mm, Diameter9-5mm, Amidon-T30 +L_Toroid Horizontal series Radial pin pitch 13.00mm diameter 7.7978mm Diameter9-5mm Amidon-T30 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D9.5mm_P15.00mm_Diameter10-5mm_Amidon-T37 +L_Toroid, Horizontal series, Radial, pin pitch=15.00mm, , diameter=9.524999999999999mm, Diameter10-5mm, Amidon-T37 +L_Toroid Horizontal series Radial pin pitch 15.00mm diameter 9.524999999999999mm Diameter10-5mm Amidon-T37 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D11.2mm_P17.00mm_Diameter12-5mm_Amidon-T44 +L_Toroid, Horizontal series, Radial, pin pitch=17.00mm, , diameter=11.176mm, Diameter12-5mm, Amidon-T44 +L_Toroid Horizontal series Radial pin pitch 17.00mm diameter 11.176mm Diameter12-5mm Amidon-T44 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D12.7mm_P20.00mm_Diameter14-5mm_Amidon-T50 +L_Toroid, Horizontal series, Radial, pin pitch=20.00mm, , diameter=12.7mm, Diameter14-5mm, Amidon-T50 +L_Toroid Horizontal series Radial pin pitch 20.00mm diameter 12.7mm Diameter14-5mm Amidon-T50 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D16.8mm_P14.70mm_Vishay_TJ3 +L_Toroid, Horizontal series, Radial, pin pitch=14.70mm, , diameter=16.8mm, Vishay, TJ3, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 14.70mm diameter 16.8mm Vishay TJ3 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D16.8mm_P14.70mm_Vishay_TJ3_BigPads +L_Toroid, Horizontal series, Radial, pin pitch=14.70mm, , diameter=16.8mm, Vishay, TJ3, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 14.70mm diameter 16.8mm Vishay TJ3 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D17.3mm_P15.24mm_Bourns_2000 +L_Toroid, Horizontal series, Radial, pin pitch=15.24mm, , diameter=17.3mm, Bourns, 2000, http://www.bourns.com/docs/Product-Datasheets/2000_series.pdf?sfvrsn=5 +L_Toroid Horizontal series Radial pin pitch 15.24mm diameter 17.3mm Bourns 2000 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D21.8mm_P19.10mm_Bourns_2100 +L_Toroid, Horizontal series, Radial, pin pitch=19.10mm, , diameter=21.8mm, Bourns, 2100, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 19.10mm diameter 21.8mm Bourns 2100 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D21.8mm_P19.60mm_Bourns_2100 +L_Toroid, Horizontal series, Radial, pin pitch=19.60mm, , diameter=21.8mm, Bourns, 2100, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 19.60mm diameter 21.8mm Bourns 2100 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D22.4mm_P19.80mm_Vishay_TJ4 +L_Toroid, Horizontal series, Radial, pin pitch=19.80mm, , diameter=22.4mm, Vishay, TJ4, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 19.80mm diameter 22.4mm Vishay TJ4 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D24.1mm_P21.80mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=21.80mm, , diameter=24.1mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 21.80mm diameter 24.1mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D24.1mm_P23.10mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=23.10mm, , diameter=24.1mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 23.10mm diameter 24.1mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D25.4mm_P22.90mm_Vishay_TJ5 +L_Toroid, Horizontal series, Radial, pin pitch=22.90mm, , diameter=25.4mm, Vishay, TJ5, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 22.90mm diameter 25.4mm Vishay TJ5 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D25.4mm_P22.90mm_Vishay_TJ5_BigPads +L_Toroid, Horizontal series, Radial, pin pitch=22.90mm, , diameter=25.4mm, Vishay, TJ5, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 22.90mm diameter 25.4mm Vishay TJ5 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D26.0mm_P5.08mm +inductor 26mm diameter toroid +SELF INDUCTOR +0 +3 +2 +Inductor_THT +L_Toroid_Horizontal_D28.0mm_P25.10mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=25.10mm, , diameter=28mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 25.10mm diameter 28mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D28.0mm_P26.67mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=26.67mm, , diameter=28mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 26.67mm diameter 28mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D32.5mm_P28.90mm_Bourns_2300 +L_Toroid, Horizontal series, Radial, pin pitch=28.90mm, , diameter=32.5mm, Bourns, 2300, http://www.bourns.com/docs/Product-Datasheets/2300_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 28.90mm diameter 32.5mm Bourns 2300 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D32.5mm_P30.00mm_Bourns_2300 +L_Toroid, Horizontal series, Radial, pin pitch=30.00mm, , diameter=32.5mm, Bourns, 2300, http://www.bourns.com/docs/Product-Datasheets/2300_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 30.00mm diameter 32.5mm Bourns 2300 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D35.1mm_P31.00mm_Vishay_TJ6 +L_Toroid, Horizontal series, Radial, pin pitch=31.00mm, , diameter=35.1mm, Vishay, TJ6, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 31.00mm diameter 35.1mm Vishay TJ6 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D40.0mm_P48.26mm +L_Toroid, Horizontal series, Radial, pin pitch=48.26mm, , diameter=40mm +L_Toroid Horizontal series Radial pin pitch 48.26mm diameter 40mm +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D41.9mm_P37.60mm_Vishay_TJ7 +L_Toroid, Horizontal series, Radial, pin pitch=37.60mm, , diameter=41.9mm, Vishay, TJ7, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 37.60mm diameter 41.9mm Vishay TJ7 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D49.3mm_P44.60mm_Vishay_TJ8 +L_Toroid, Horizontal series, Radial, pin pitch=44.60mm, , diameter=49.3mm, Vishay, TJ8, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 44.60mm diameter 49.3mm Vishay TJ8 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D69.1mm_P63.20mm_Vishay_TJ9 +L_Toroid, Horizontal series, Radial, pin pitch=63.20mm, , diameter=69.1mm, Vishay, TJ9, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 63.20mm diameter 69.1mm Vishay TJ9 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L10.0mm_W5.0mm_P5.08mm +L_Toroid, Vertical series, Radial, pin pitch=5.08mm, , length*width=10*5mm^2 +L_Toroid Vertical series Radial pin pitch 5.08mm length 10mm width 5mm +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L13.0mm_W6.5mm_P5.60mm +L_Toroid, Vertical series, Radial, pin pitch=5.60mm, , length*width=13*6.5mm^2 +L_Toroid Vertical series Radial pin pitch 5.60mm length 13mm width 6.5mm +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L14.0mm_W5.6mm_P5.30mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=5.30mm, , length*width=14*5.6mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 5.30mm length 14mm width 5.6mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L14.0mm_W6.3mm_P4.57mm_Pulse_A +L_Toroid, Vertical series, Radial, pin pitch=4.57mm, , length*width=13.97*6.35mm^2, Pulse, A, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 4.57mm length 13.97mm width 6.35mm Pulse A +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L14.7mm_W8.6mm_P5.58mm_Pulse_KM-1 +L_Toroid, Vertical series, Radial, pin pitch=5.58mm, , length*width=14.73*8.64mm^2, Pulse, KM-1, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 5.58mm length 14.73mm width 8.64mm Pulse KM-1 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.0mm_W8.0mm_P7.62mm +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=16*8mm^2 +L_Toroid Vertical series Radial pin pitch 7.62mm length 16mm width 8mm +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.3mm_W7.1mm_P7.11mm_Pulse_H +L_Toroid, Vertical series, Radial, pin pitch=7.11mm, , length*width=16.26*7.11mm^2, Pulse, H, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.11mm length 16.26mm width 7.11mm Pulse H +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.4mm_W7.6mm_P6.60mm_Vishay_TJ3 +L_Toroid, Vertical series, Radial, pin pitch=6.60mm, , length*width=16.4*7.6mm^2, Vishay, TJ3, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 6.60mm length 16.4mm width 7.6mm Vishay TJ3 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.5mm_W11.4mm_P7.62mm_Pulse_KM-2 +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=16.51*11.43mm^2, Pulse, KM-2, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.62mm length 16.51mm width 11.43mm Pulse KM-2 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.8mm_W9.2mm_P7.10mm_Vishay_TJ3 +L_Toroid, Vertical series, Radial, pin pitch=7.10mm, , length*width=16.8*9.2mm^2, Vishay, TJ3, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 7.10mm length 16.8mm width 9.2mm Vishay TJ3 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.8mm_W9.2mm_P7.10mm_Vishay_TJ3_BigPads +L_Toroid, Vertical series, Radial, pin pitch=7.10mm, , length*width=16.8*9.2mm^2, Vishay, TJ3, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 7.10mm length 16.8mm width 9.2mm Vishay TJ3 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L17.8mm_W8.1mm_P7.62mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=17.8*8.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 7.62mm length 17.8mm width 8.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L17.8mm_W9.7mm_P7.11mm_Pulse_B +L_Toroid, Vertical series, Radial, pin pitch=7.11mm, , length*width=17.78*9.65mm^2, Pulse, B, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.11mm length 17.78mm width 9.65mm Pulse B +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L19.1mm_W8.1mm_P7.10mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=7.10mm, , length*width=19.1*8.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 7.10mm length 19.1mm width 8.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W8.4mm_P8.38mm_Pulse_G +L_Toroid, Vertical series, Radial, pin pitch=8.38mm, , length*width=21.59*8.38mm^2, Pulse, G, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 8.38mm length 21.59mm width 8.38mm Pulse G +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W9.1mm_P8.40mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=8.40mm, , length*width=21.6*9.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 8.40mm length 21.6mm width 9.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W9.5mm_P7.11mm_Pulse_C +L_Toroid, Vertical series, Radial, pin pitch=7.11mm, , length*width=21.59*9.53mm^2, Pulse, C, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.11mm length 21.59mm width 9.53mm Pulse C +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W11.4mm_P7.62mm_Pulse_KM-3 +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=21.59*11.43mm^2, Pulse, KM-3, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.62mm length 21.59mm width 11.43mm Pulse KM-3 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L22.4mm_W10.2mm_P7.90mm_Vishay_TJ4 +L_Toroid, Vertical series, Radial, pin pitch=7.90mm, , length*width=22.4*10.2mm^2, Vishay, TJ4, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 7.90mm length 22.4mm width 10.2mm Vishay TJ4 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L24.6mm_W15.5mm_P11.44mm_Pulse_KM-4 +L_Toroid, Vertical series, Radial, pin pitch=11.44mm, , length*width=24.64*15.5mm^2, Pulse, KM-4, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 11.44mm length 24.64mm width 15.5mm Pulse KM-4 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L25.4mm_W14.7mm_P12.20mm_Vishay_TJ5 +L_Toroid, Vertical series, Radial, pin pitch=12.20mm, , length*width=25.4*14.7mm^2, Vishay, TJ5, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 12.20mm length 25.4mm width 14.7mm Vishay TJ5 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L25.4mm_W14.7mm_P12.20mm_Vishay_TJ5_BigPads +L_Toroid, Vertical series, Radial, pin pitch=12.20mm, , length*width=25.4*14.7mm^2, Vishay, TJ5, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 12.20mm length 25.4mm width 14.7mm Vishay TJ5 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L26.7mm_W14.0mm_P10.16mm_Pulse_D +L_Toroid, Vertical series, Radial, pin pitch=10.16mm, , length*width=26.67*13.97mm^2, Pulse, D, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 10.16mm length 26.67mm width 13.97mm Pulse D +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L28.6mm_W14.3mm_P11.43mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=11.43mm, , length*width=28.6*14.3mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 11.43mm length 28.6mm width 14.3mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L31.8mm_W15.9mm_P13.50mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=13.50mm, , length*width=31.8*15.9mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 13.50mm length 31.8mm width 15.9mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L33.0mm_W17.8mm_P12.70mm_Pulse_KM-5 +L_Toroid, Vertical series, Radial, pin pitch=12.70mm, , length*width=33.02*17.78mm^2, Pulse, KM-5, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 12.70mm length 33.02mm width 17.78mm Pulse KM-5 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L35.1mm_W21.1mm_P18.50mm_Vishay_TJ6 +L_Toroid, Vertical series, Radial, pin pitch=18.50mm, , length*width=35.1*21.1mm^2, Vishay, TJ6, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 18.50mm length 35.1mm width 21.1mm Vishay TJ6 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L35.6mm_W17.8mm_P12.70mm_Pulse_E +L_Toroid, Vertical series, Radial, pin pitch=12.70mm, , length*width=35.56*17.78mm^2, Pulse, E, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 12.70mm length 35.56mm width 17.78mm Pulse E +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L41.9mm_W17.8mm_P12.70mm_Pulse_F +L_Toroid, Vertical series, Radial, pin pitch=12.70mm, , length*width=41.91*17.78mm^2, Pulse, F, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 12.70mm length 41.91mm width 17.78mm Pulse F +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L41.9mm_W19.1mm_P15.80mm_Vishay_TJ7 +L_Toroid, Vertical series, Radial, pin pitch=15.80mm, , length*width=41.9*19.1mm^2, Vishay, TJ7, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 15.80mm length 41.9mm width 19.1mm Vishay TJ7 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L46.0mm_W19.1mm_P21.80mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=21.80mm, , length*width=46*19.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 21.80mm length 46mm width 19.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L48.8mm_W25.4mm_P20.80mm_Vishay_TJ8 +L_Toroid, Vertical series, Radial, pin pitch=20.80mm, , length*width=48.8*25.4mm^2, Vishay, TJ8, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 20.80mm length 48.8mm width 25.4mm Vishay TJ8 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L54.0mm_W23.8mm_P20.10mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=20.10mm, , length*width=54*23.8mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 20.10mm length 54mm width 23.8mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L67.6mm_W36.1mm_P31.80mm_Vishay_TJ9 +L_Toroid, Vertical series, Radial, pin pitch=31.80mm, , length*width=67.6*36.1mm^2, Vishay, TJ9, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 31.80mm length 67.6mm width 36.1mm Vishay TJ9 +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged2Bar_Pad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, bridged with 2 copper strips +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged2Bar_RoundedPad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm, rounded Pads, 0.3mm gap, bridged with 2 copper strips +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged_Pad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, bridged with 1 copper strip +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged_RoundedPad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm, rounded Pads, 0.3mm gap, bridged with 1 copper strip +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Open_Pad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, open +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Open_RoundedPad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm, rounded Pads, 0.3mm gap, open +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Open_TrianglePad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Triangular Pads, 0.3mm gap, open +solder jumper open +0 +2 +2 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_Pad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_Pad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_RoundedPad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_RoundedPad1.0x1.5mm_NumberLabels +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_Pad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_Pad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_RoundedPad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_RoundedPad1.0x1.5mm_NumberLabels +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_Pad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm Pads, 0.3mm gap, open +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_Pad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, open, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_RoundedPad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, open +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_RoundedPad1.0x1.5mm_NumberLabels +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, open, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P2.0mm_Open_TrianglePad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Triangular Pads, 0.3mm gap, open +solder jumper open +0 +5 +3 +Jumper +SolderJumper-3_P2.0mm_Open_TrianglePad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Triangular Pads, 0.3mm gap, open, labeled with numbers +solder jumper open +0 +5 +3 +LED_SMD +LED-APA102-2020 +http://www.led-color.com/upload/201604/APA102-2020%20SMD%20LED.pdf +LED RGB SPI +0 +8 +6 +LED_SMD +LED-L1T2_LUMILEDS +http://www.lumileds.com/uploads/438/DS133-pdf +LUMILEDS LUXEON TX L1T2 LED +0 +3 +3 +LED_SMD +LED_1W_3W_R8 +https://www.gme.cz/data/attachments/dsh.518-234.1.pdf +LED 1W 3W 5W +0 +3 +3 +LED_SMD +LED_0201_0603Metric +LED SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +LED +0 +4 +2 +LED_SMD +LED_0201_0603Metric_Castellated +LED SMD 0201 (0603 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +LED castellated +0 +4 +2 +LED_SMD +LED_0201_0603Metric_Pad0.64x0.40mm_HandSolder +LED SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +LED handsolder +0 +4 +2 +LED_SMD +LED_0402_1005Metric +LED SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_0402_1005Metric_Castellated +LED SMD 0402 (1005 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_0402_1005Metric_Pad0.77x0.64mm_HandSolder +LED SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_0603_1608Metric +LED SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_0603_1608Metric_Castellated +LED SMD 0603 (1608 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_0603_1608Metric_Pad1.05x0.95mm_HandSolder +LED SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_0805_2012Metric +LED SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_0805_2012Metric_Castellated +LED SMD 0805 (2012 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_0805_2012Metric_Pad1.15x1.40mm_HandSolder +LED SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_1206_3216Metric +LED SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_1206_3216Metric_Castellated +LED SMD 1206 (3216 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_1206_3216Metric_Pad1.42x1.75mm_HandSolder +LED SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_1206_3216Metric_ReverseMount_Hole1.8x2.4mm +LED SMD 1206 (3216 Metric), reverse mount, square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode reverse +0 +2 +2 +LED_SMD +LED_1210_3225Metric +LED SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_1210_3225Metric_Castellated +LED SMD 1210 (3225 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_1210_3225Metric_Pad1.42x2.65mm_HandSolder +LED SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_1812_4532Metric +LED SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_1812_4532Metric_Castellated +LED SMD 1812 (4532 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_1812_4532Metric_Pad1.30x3.40mm_HandSolder +LED SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_2010_5025Metric +LED SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_2010_5025Metric_Castellated +LED SMD 2010 (5025 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_2010_5025Metric_Pad1.52x2.65mm_HandSolder +LED SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_2512_6332Metric +LED SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_2512_6332Metric_Castellated +LED SMD 2512 (6332 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_2512_6332Metric_Pad1.52x3.35mm_HandSolder +LED SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_2816_7142Metric +LED SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_2816_7142Metric_Castellated +LED SMD 2816 (7142 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_2816_7142Metric_Pad3.20x4.45mm_HandSolder +LED SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_ASMB-KTF0-0A306 +2220 Tricolor PLCC-4 LED, https://docs.broadcom.com/docs/ASMB-KTF0-0A306-DS100 +Tricolor LED +0 +4 +4 +LED_SMD +LED_Avago_PLCC4_3.2x2.8mm_CW +https://docs.broadcom.com/docs/AV02-4186EN +LED Avago PLCC-4 ASMB-MTB0-0A3A2 +0 +4 +4 +LED_SMD +LED_Avago_PLCC6_3x2.8mm +https://docs.broadcom.com/docs/AV02-3793EN +LED Avago PLCC-6 ASMT-YTB7-0AA02 +0 +6 +6 +LED_SMD +LED_Cree-PLCC4_2x2mm_CW +2.0mm x 2.0mm PLCC4 LED, http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/HB/Data-Sheets/CLMVBFKA.pdf +LED Cree PLCC-4 +0 +4 +4 +LED_SMD +LED_Cree-PLCC4_3.2x2.8mm_CCW +3.2mm x 2.8mm PLCC4 LED, http://www.cree.com/led-components/media/documents/CLV1AFKB(874).pdf +LED Cree PLCC-4 +0 +4 +4 +LED_SMD +LED_Cree-PLCC4_5x5mm_CW +5.0mm x 5.0mm PLCC4 LED +LED Cree PLCC-4 +0 +4 +4 +LED_SMD +LED_Cree-PLCC6_4.7x1.5mm +4.7mm x 1.5mm PLCC6 LED, http://www.cree.com/led-components/media/documents/1381-QLS6AFKW.pdf +LED Cree PLCC-6 +0 +6 +6 +LED_SMD +LED_Cree-XB +http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/XLampXBD.pdf +LED Cree XB +0 +5 +3 +LED_SMD +LED_Cree-XH +http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds-XHB.pdf +LED Cree XH +0 +8 +2 +LED_SMD +LED_Cree-XHP35 +http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds--XHP35.pdf +LED Cree XHP35 +0 +6 +3 +LED_SMD +LED_Cree-XHP50_6V +Cree XHP50, 6V footprint, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP50.pdf +LED Cree XHP50 +0 +15 +3 +LED_SMD +LED_Cree-XHP50_12V +Cree XHP50, 12V footprint, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP50.pdf +LED XHP50 Cree +0 +15 +3 +LED_SMD +LED_Cree-XHP70_6V +Cree XHP70 LED, 6V version, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP70.pdf +LED Cree XHP70 +0 +15 +3 +LED_SMD +LED_Cree-XHP70_12V +Cree XHP70 LED, 12V version, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP70.pdf +LED Cree XHP70 +0 +15 +3 +LED_SMD +LED_Cree-XP +LED Cree-XP http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/XLampXPE2.pdf +LED Cree XP +0 +6 +3 +LED_SMD +LED_Cree-XP-G +LED Cree-XP-G http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/XLampXPG.pdf +LED Cree XP-G +0 +6 +3 +LED_SMD +LED_Cree-XQ +LED Cree-XQ http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds-XQB.pdf +LED Cree XQ +0 +2 +2 +LED_SMD +LED_Cree-XQ_HandSoldering +LED Cree-XQ handsoldering pads http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds-XQB.pdf +LED Cree XQ +0 +2 +2 +LED_SMD +LED_Dialight_591 +LED SMD 3mm Right Angle series (http://www.dialightsignalsandcomponents.com/Assets/Drawings/2D_Drawings_DrawingDetailedSpec/C17354.pdf) +LED Dialight 591 +0 +2 +2 +LED_SMD +LED_Inolux_IN-PI554FCH_PLCC4_5.0x5.0mm_P3.2mm +http://www.inolux-corp.com/datasheet/SMDLED/Addressable%20LED/IN-PI554FCH.pdf +RGB LED NeoPixel addressable +0 +4 +4 +LED_SMD +LED_Kingbright_AAA3528ESGCT +Kingbright, dual LED, 3.5 x 2.8 mm Surface Mount LED Lamp (http://www.kingbrightusa.com/images/catalog/SPEC/AAA3528ESGCT.pdf) +dual led smd +0 +4 +4 +LED_SMD +LED_Kingbright_APFA3010_3x1.5mm_Horizontal +LED RGB, APFA3010, http://www.kingbrightusa.com/images/catalog/SPEC/APFA3010LSEEZGKQBKC.pdf +LED RGB APFA3010 KINGBRIGHT 3x1.5mm +0 +4 +4 +LED_SMD +LED_LiteOn_LTST-C19HE1WT +LiteOn RGB LED; https://optoelectronics.liteon.com/upload/download/DS22-2008-0044/LTST-C19HE1WT.pdf +LED RGB Chip SMD +0 +4 +4 +LED_SMD +LED_LiteOn_LTST-S326 +http://optoelectronics.liteon.com/upload/download/DS22-2000-287/LTST-S326KGJRKT.PDF +LED SMD right angle CCA +0 +3 +3 +LED_SMD +LED_Lumex_SML-LX0303SIUPGUSB +Lumex RGB LED, clear, SMD, https://www.lumex.com/spec/SML-LX0303SIUPGUSB.pdf +LED RGB +0 +4 +4 +LED_SMD +LED_Osram_Lx_P47F_D2mm_ReverseMount +OSRAM, reverse-mount LED, SMD, 2mm diameter, http://www.farnell.com/datasheets/2711587.pdf +LED ReverseMount Reverse +0 +4 +2 +LED_SMD +LED_PLCC-2 +LED PLCC-2 SMD package +LED PLCC-2 SMD +0 +2 +2 +LED_SMD +LED_PLCC_2835 +https://www.luckylight.cn/media/component/data-sheet/R2835BC-B2M-M10.pdf +LED +0 +2 +2 +LED_SMD +LED_PLCC_2835_Handsoldering +https://www.luckylight.cn/media/component/data-sheet/R2835BC-B2M-M10.pdf +LED +0 +2 +2 +LED_SMD +LED_RGB_1210 +RGB LED 3.2x2.7mm http://www.avagotech.com/docs/AV02-0610EN +LED 3227 +0 +4 +4 +LED_SMD +LED_RGB_5050-6 +http://cdn.sparkfun.com/datasheets/Components/LED/5060BRG4.pdf +RGB LED 5050-6 +0 +6 +6 +LED_SMD +LED_RGB_Cree-PLCC-6_6x5mm_P2.1mm +http://www.farnell.com/datasheets/2003905.pdf +LED RGB PLCC-6 CLP6C-FBK +0 +6 +6 +LED_SMD +LED_RGB_Getian_GT-P6PRGB4303 +https://www.gme.sk/img/cache/doc/518/177/vykonova-led-getian-gt-p6prgb4303-datasheet-1.pdf +LED RGB +0 +7 +7 +LED_SMD +LED_RGB_PLCC-6 +RGB LED PLCC-6 +RGB LED PLCC-6 +0 +6 +6 +LED_SMD +LED_ROHM_SMLVN6 +https://www.rohm.com/datasheet/SMLVN6RGB1U +LED ROHM SMLVN6 +0 +6 +6 +LED_SMD +LED_SK6805_PLCC4_2.4x2.7mm_P1.3mm +https://cdn-shop.adafruit.com/product-files/3484/3484_Datasheet.pdf +LED RGB NeoPixel Nano +0 +4 +4 +LED_SMD +LED_SK6812MINI_PLCC4_3.5x3.5mm_P1.75mm +https://cdn-shop.adafruit.com/product-files/2686/SK6812MINI_REV.01-1-2.pdf +LED RGB NeoPixel Mini +0 +4 +4 +LED_SMD +LED_SK6812_EC15_1.5x1.5mm +http://www.newstar-ledstrip.com/product/20181119172602110.pdf +LED RGB NeoPixel +0 +4 +4 +LED_SMD +LED_SK6812_PLCC4_5.0x5.0mm_P3.2mm +https://cdn-shop.adafruit.com/product-files/1138/SK6812+LED+datasheet+.pdf +LED RGB NeoPixel +0 +4 +4 +LED_SMD +LED_WS2812B_PLCC4_5.0x5.0mm_P3.2mm +https://cdn-shop.adafruit.com/datasheets/WS2812B.pdf +LED RGB NeoPixel +0 +4 +4 +LED_SMD +LED_WS2812_PLCC6_5.0x5.0mm_P1.6mm +https://cdn-shop.adafruit.com/datasheets/WS2812.pdf +LED RGB NeoPixel +0 +6 +6 +LED_SMD +LED_Yuji_5730 +LED,Yuji,5730,https://cdn.shopify.com/s/files/1/0344/6401/files/YJWJ014-1.1_YJ-BC-5730L-G02.pdf +LED Yuji 5730 +0 +3 +2 +LED_SMD +LED_miniPLCC_2315 +https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DAV02-2205EN_DS_ASMT-TxBM_2014-05-09.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430858274704&ssbinary=true +LED +0 +2 +2 +LED_SMD +LED_miniPLCC_2315_Handsoldering +https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DAV02-2205EN_DS_ASMT-TxBM_2014-05-09.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430858274704&ssbinary=true +LED +0 +2 +2 +LED_THT +LED_BL-FL7680RGB +'Piranha' RGB LED, through hole, common anode, 7.62x7.62mm, BGRA pin order, https://cdn-shop.adafruit.com/datasheets/BL-FL7680RGB.pdf +RGB LED Piranha Super-Flux BetLux +0 +4 +4 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O1.27mm_Z1.6mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O1.27mm_Z4.9mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O1.27mm_Z8.2mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O3.81mm_Z1.6mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O3.81mm_Z4.9mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O3.81mm_Z8.2mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O6.35mm_Z1.6mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O6.35mm_Z4.9mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O6.35mm_Z8.2mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W3.3mm_H2.4mm +LED, Round, Rectangular size 3.3x2.4mm^2 diameter 1.8mm, 2 pins +LED Round Rectangular size 3.3x2.4mm^2 diameter 1.8mm 2 pins +0 +2 +2 +LED_THT +LED_D2.0mm_W4.0mm_H2.8mm_FlatTop +LED, Round, FlatTop, Rectangular size 4.0x2.8mm^2 diameter 2.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-1034IDT(Ver.9A).pdf +LED Round FlatTop Rectangular size 4.0x2.8mm^2 diameter 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D2.0mm_W4.8mm_H2.5mm_FlatTop +LED, Round, FlatTop, Rectangular size 4.8x2.5mm^2 diameter 2.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-13GD(Ver.11B).pdf +LED Round FlatTop Rectangular size 4.8x2.5mm^2 diameter 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm +LED, diameter 3.0mm, 2 pins +LED diameter 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm-3 +LED, diameter 3.0mm, 2 pins, diameter 3.0mm, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-3VSURKCGKC(Ver.8A).pdf +LED diameter 3.0mm 2 pins diameter 3.0mm 3 pins +0 +3 +3 +LED_THT +LED_D3.0mm_Clear +IR-LED, diameter 3.0mm, 2 pins, color: clear +IR infrared LED diameter 3.0mm 2 pins clear +0 +2 +2 +LED_THT +LED_D3.0mm_FlatTop +LED, Round, FlatTop, diameter 3.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-47XEC(Ver.9A).pdf +LED Round FlatTop diameter 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm_Clear +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm_IRBlack +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm_IRGrey +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z6.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z10.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O3.81mm_Z2.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O3.81mm_Z6.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O3.81mm_Z10.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O6.35mm_Z2.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O6.35mm_Z6.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O6.35mm_Z10.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_IRBlack +IR-ED, diameter 3.0mm, 2 pins, color: black +IR infrared LED diameter 3.0mm 2 pins black +0 +2 +2 +LED_THT +LED_D3.0mm_IRGrey +IR-LED, diameter 3.0mm, 2 pins, color: grey +IR infrared LED diameter 3.0mm 2 pins grey +0 +2 +2 +LED_THT +LED_D4.0mm +LED, diameter 4.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-43GD(Ver.12B).pdf +LED diameter 4.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm-3 +LED, diameter 5.0mm, 2 pins, diameter 5.0mm, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-59EGC(Ver.17A).pdf +LED diameter 5.0mm 2 pins diameter 5.0mm 3 pins +0 +3 +3 +LED_THT +LED_D5.0mm-3_Horizontal_O3.81mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 3 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 3 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +3 +3 +LED_THT +LED_D5.0mm-4_RGB +LED, diameter 5.0mm, 2 pins, diameter 5.0mm, 3 pins, diameter 5.0mm, 4 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-154A4SUREQBFZGEW(Ver.9A).pdf +LED diameter 5.0mm 2 pins diameter 5.0mm 3 pins diameter 5.0mm 4 pins RGB RGBLED +0 +4 +4 +LED_THT +LED_D5.0mm-4_RGB_Staggered_Pins +LED, diameter 5.0mm, 4 pins, WP154A4, http://webtest4.kingbright.com/attachments/file/psearch/000/00/00/L-154A4SUREQBFZGEW(Ver.9A).pdf +rgb led +0 +4 +4 +LED_THT +LED_D5.0mm-4_RGB_Wide_Pins +LED, diameter 5.0mm, 2 pins, diameter 5.0mm, 3 pins, diameter 5.0mm, 4 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-154A4SUREQBFZGEW(Ver.9A).pdf +LED diameter 5.0mm 2 pins diameter 5.0mm 3 pins diameter 5.0mm 4 pins RGB RGBLED +0 +4 +4 +LED_THT +LED_D5.0mm_Clear +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_FlatTop +LED, Round, FlatTop, diameter 5.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-483GDT(Ver.15B).pdf +LED Round FlatTop diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm_Clear +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm_IRBlack +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm_IRGrey +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z9.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z15.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O3.81mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O3.81mm_Z9.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O3.81mm_Z15.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O6.35mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O6.35mm_Z9.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O6.35mm_Z15.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_IRBlack +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_IRGrey +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D8.0mm +LED, diameter 8.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LED8MMGE_LED8MMGN_LED8MMRT%23KIN.pdf +LED diameter 8.0mm 2 pins +0 +2 +2 +LED_THT +LED_D8.0mm-3 +LED, diameter 8.0mm, 2 pins, diameter 8.0mm, 3 pins +LED diameter 8.0mm 2 pins diameter 8.0mm 3 pins +0 +3 +3 +LED_THT +LED_D10.0mm +LED, diameter 10.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LED10-4500RT%23KIN.pdf +LED diameter 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D10.0mm-3 +LED, diameter 10.0mm, 2 pins, diameter 10.0mm, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-819EGW(Ver.14A).pdf +LED diameter 10.0mm 2 pins diameter 10.0mm 3 pins +0 +3 +3 +LED_THT +LED_D20.0mm +LED, diameter 20.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/DLC2-6GD%28V6%29.pdf +LED diameter 20.0mm 2 pins +0 +2 +2 +LED_THT +LED_Oval_W5.2mm_H3.8mm +LED_Oval, Oval, Oval size 5.2x3.8mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-5603QBC-D(Ver.12B).pdf +LED_Oval Oval Oval size 5.2x3.8mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.0mm_H2.0mm +LED_Rectangular, Rectangular, Rectangular size 3.0x2.0mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 3.0x2.0mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.9mm_H1.8mm +LED_Rectangular, Rectangular, Rectangular size 3.9x1.8mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-2774GD(Ver.7B).pdf +LED_Rectangular Rectangular Rectangular size 3.9x1.8mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.9mm_H1.8mm_FlatTop +LED_Rectangular, Rectangular, Rectangular size 3.9x1.8mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-2774GD(Ver.7B).pdf +LED_Rectangular Rectangular Rectangular size 3.9x1.8mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.9mm_H1.9mm +LED_Rectangular, Rectangular, Rectangular size 3.9x1.9mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-144GDT(Ver.14B).pdf +LED_Rectangular Rectangular Rectangular size 3.9x1.9mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm-3Pins +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 3 pins +0 +3 +3 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O1.27mm_Z1.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O1.27mm_Z3.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O1.27mm_Z5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O3.81mm_Z1.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O3.81mm_Z3.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O3.81mm_Z5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O6.35mm_Z1.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O6.35mm_Z3.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O6.35mm_Z5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x5.0mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 5.0x5.0mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W7.62mm_H4.55mm_P5.08mm_R3 +Datasheet can be found at https://www.gme.cz/data/attachments/dsh.511-795.1.pdf +LED automotive super flux 7.62mm +0 +4 +2 +LED_THT +LED_SideEmitter_Rectangular_W4.5mm_H1.6mm +LED_SideEmitter_Rectangular, Rectangular, SideEmitter, Rectangular size 4.5x1.6mm^2, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LED15MMGE_LED15MMGN%23KIN.pdf +LED_SideEmitter_Rectangular Rectangular SideEmitter Rectangular size 4.5x1.6mm^2 2 pins +0 +2 +2 +LED_THT +LED_VCCLite_5381H1_6.35x6.35mm +Red 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Red 5381 Series LED +0 +2 +2 +LED_THT +LED_VCCLite_5381H3_6.35x6.35mm +Amber 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Amber 5381 Series LED +0 +2 +2 +LED_THT +LED_VCCLite_5381H5_6.35x6.35mm +Green 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Green 5381 Series LED +0 +2 +2 +LED_THT +LED_VCCLite_5381H7_6.35x6.35mm +Yellow 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Yellow 5381 Series LED +0 +2 +2 +Module +A20_OLINUXINO_LIME2 +A20 Olinuxino LIME2, 1.2GHz, 512-1024MB RAM, Micro-SD, NAND or eMMC, 1000Mbit Ethernet +A20 Olimex Olinuxino LIME2 development board +0 +180 +180 +Module +Adafruit_HUZZAH_ESP8266_breakout +32-bit microcontroller module with WiFi, https://www.adafruit.com/product/2471 +ESP8266 WiFi microcontroller +0 +20 +20 +Module +Adafruit_HUZZAH_ESP8266_breakout_WithMountingHoles +32-bit microcontroller module with WiFi, https://www.adafruit.com/product/2471 +ESP8266 WiFi microcontroller +0 +20 +20 +Module +Arduino_Nano +Arduino Nano, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino Nano +0 +30 +30 +Module +Arduino_Nano_WithMountingHoles +Arduino Nano, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino Nano +0 +30 +30 +Module +Arduino_UNO_R2 +Arduino UNO R2, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R2 +0 +30 +30 +Module +Arduino_UNO_R2_WithMountingHoles +Arduino UNO R2, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R2 +0 +30 +30 +Module +Arduino_UNO_R3 +Arduino UNO R3, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R3 +0 +32 +32 +Module +Arduino_UNO_R3_WithMountingHoles +Arduino UNO R3, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R3 +0 +32 +32 +Module +BeagleBoard_PocketBeagle +PocketBeagle, https://github.com/beagleboard/pocketbeagle/wiki/System-Reference-Manual#71_Expansion_Header_Connectors +PocketBeagle +0 +72 +72 +Module +Maple_Mini +Maple Mini, http://docs.leaflabs.com/static.leaflabs.com/pub/leaflabs/maple-docs/0.0.12/hardware/maple-mini.html +Maple Mini +0 +40 +40 +Module +Onion_Omega2+ +https://onion.io/omega2/ +Omega Onion module +0 +32 +32 +Module +Onion_Omega2S +https://github.com/OnionIoT/Omega2/raw/master/Documents/Omega2S%20Datasheet.pdf +onion omega module +0 +89 +64 +Module +Pololu_Breakout-16_15.2x20.3mm +Pololu Breakout 16-pin 15.2x20.3mm 0.6x0.8\ +Pololu Breakout +0 +16 +16 +Module +Raspberry_Pi_Zero_Socketed_THT_FaceDown_MountingHoles +Raspberry Pi Zero using through hole straight pin socket, 2x20, 2.54mm pitch, https://www.raspberrypi.org/documentation/hardware/raspberrypi/mechanical/rpi_MECH_Zero_1p2.pdf +raspberry pi zero through hole +0 +40 +40 +Module +ST_Morpho_Connector_144_STLink +ST Morpho Connector 144 With STLink +ST Morpho Connector 144 STLink +0 +148 +148 +Module +ST_Morpho_Connector_144_STLink_MountingHoles +ST Morpho Connector 144 With STLink +ST Morpho Connector 144 STLink +0 +148 +148 +Module +Texas_EUK_R-PDSS-T7_THT +Texas Instruments EUK 7 Pin Double Sided Module +module pcb +0 +7 +7 +Module +Texas_EUS_R-PDSS-T5_THT +Texas Instruments EUS 5 Pin Double Sided Module +module pcb +0 +5 +5 +Module +Texas_EUW_R-PDSS-T7_THT +Texas Instruments EUW 7 Pin Double Sided Module +module pcb +0 +7 +7 +Module +WEMOS_D1_mini_light +16-pin module, column spacing 22.86 mm (900 mils), https://wiki.wemos.cc/products:d1:d1_mini, https://c1.staticflickr.com/1/734/31400410271_f278b087db_z.jpg +ESP8266 WiFi microcontroller +0 +16 +16 +MountingEquipment +DINRailAdapter_3xM3_PhoenixContact_1201578 +https://www.phoenixcontact.com/online/portal/us?uri=pxc-oc-itemdetail:pid=1201578&library=usen&tab=1 +DIN rail adapter universal three M3 clearance holes +0 +0 +0 +MountingHole +MountingHole_2.1mm +Mounting Hole 2.1mm, no annular +mounting hole 2.1mm no annular +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2 +Mounting Hole 2.2mm, no annular, M2 +mounting hole 2.2mm no annular m2 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_DIN965 +Mounting Hole 2.2mm, no annular, M2, DIN965 +mounting hole 2.2mm no annular m2 din965 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_DIN965_Pad +Mounting Hole 2.2mm, M2, DIN965 +mounting hole 2.2mm m2 din965 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_DIN965_Pad_TopBottom +Mounting Hole 2.2mm, M2, DIN965 +mounting hole 2.2mm m2 din965 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_DIN965_Pad_TopOnly +Mounting Hole 2.2mm, M2, DIN965 +mounting hole 2.2mm m2 din965 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_ISO7380 +Mounting Hole 2.2mm, no annular, M2, ISO7380 +mounting hole 2.2mm no annular m2 iso7380 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_ISO7380_Pad +Mounting Hole 2.2mm, M2, ISO7380 +mounting hole 2.2mm m2 iso7380 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_ISO7380_Pad_TopBottom +Mounting Hole 2.2mm, M2, ISO7380 +mounting hole 2.2mm m2 iso7380 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_ISO7380_Pad_TopOnly +Mounting Hole 2.2mm, M2, ISO7380 +mounting hole 2.2mm m2 iso7380 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_ISO14580 +Mounting Hole 2.2mm, no annular, M2, ISO14580 +mounting hole 2.2mm no annular m2 iso14580 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_ISO14580_Pad +Mounting Hole 2.2mm, M2, ISO14580 +mounting hole 2.2mm m2 iso14580 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_ISO14580_Pad_TopBottom +Mounting Hole 2.2mm, M2, ISO14580 +mounting hole 2.2mm m2 iso14580 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_ISO14580_Pad_TopOnly +Mounting Hole 2.2mm, M2, ISO14580 +mounting hole 2.2mm m2 iso14580 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_Pad +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_Pad_TopBottom +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_Pad_TopOnly +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_Pad_Via +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +9 +1 +MountingHole +MountingHole_2.5mm +Mounting Hole 2.5mm, no annular +mounting hole 2.5mm no annular +0 +0 +0 +MountingHole +MountingHole_2.5mm_Pad +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +1 +1 +MountingHole +MountingHole_2.5mm_Pad_TopBottom +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +3 +1 +MountingHole +MountingHole_2.5mm_Pad_TopOnly +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +2 +1 +MountingHole +MountingHole_2.5mm_Pad_Via +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +9 +1 +MountingHole +MountingHole_2.7mm +Mounting Hole 2.7mm, no annular +mounting hole 2.7mm no annular +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5 +Mounting Hole 2.7mm, no annular, M2.5 +mounting hole 2.7mm no annular m2.5 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_DIN965 +Mounting Hole 2.7mm, no annular, M2.5, DIN965 +mounting hole 2.7mm no annular m2.5 din965 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_DIN965_Pad +Mounting Hole 2.7mm, M2.5, DIN965 +mounting hole 2.7mm m2.5 din965 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_DIN965_Pad_TopBottom +Mounting Hole 2.7mm, M2.5, DIN965 +mounting hole 2.7mm m2.5 din965 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_DIN965_Pad_TopOnly +Mounting Hole 2.7mm, M2.5, DIN965 +mounting hole 2.7mm m2.5 din965 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380 +Mounting Hole 2.7mm, no annular, M2.5, ISO7380 +mounting hole 2.7mm no annular m2.5 iso7380 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380_Pad +Mounting Hole 2.7mm, M2.5, ISO7380 +mounting hole 2.7mm m2.5 iso7380 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380_Pad_TopBottom +Mounting Hole 2.7mm, M2.5, ISO7380 +mounting hole 2.7mm m2.5 iso7380 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380_Pad_TopOnly +Mounting Hole 2.7mm, M2.5, ISO7380 +mounting hole 2.7mm m2.5 iso7380 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580 +Mounting Hole 2.7mm, no annular, M2.5, ISO14580 +mounting hole 2.7mm no annular m2.5 iso14580 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580_Pad +Mounting Hole 2.7mm, M2.5, ISO14580 +mounting hole 2.7mm m2.5 iso14580 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580_Pad_TopBottom +Mounting Hole 2.7mm, M2.5, ISO14580 +mounting hole 2.7mm m2.5 iso14580 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580_Pad_TopOnly +Mounting Hole 2.7mm, M2.5, ISO14580 +mounting hole 2.7mm m2.5 iso14580 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad +Mounting Hole 2.7mm, M2.5 +mounting hole 2.7mm m2.5 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad_TopBottom +Mounting Hole 2.7mm, M2.5 +mounting hole 2.7mm m2.5 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad_TopOnly +Mounting Hole 2.7mm, M2.5 +mounting hole 2.7mm m2.5 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad_Via +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +9 +1 +MountingHole +MountingHole_2.7mm_Pad +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +1 +1 +MountingHole +MountingHole_2.7mm_Pad_TopBottom +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +3 +1 +MountingHole +MountingHole_2.7mm_Pad_TopOnly +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +2 +1 +MountingHole +MountingHole_2.7mm_Pad_Via +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +9 +1 +MountingHole +MountingHole_2mm +Mounting Hole 2mm, no annular +mounting hole 2mm no annular +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3 +Mounting Hole 3.2mm, no annular, M3 +mounting hole 3.2mm no annular m3 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_DIN965 +Mounting Hole 3.2mm, no annular, M3, DIN965 +mounting hole 3.2mm no annular m3 din965 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_DIN965_Pad +Mounting Hole 3.2mm, M3, DIN965 +mounting hole 3.2mm m3 din965 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_DIN965_Pad_TopBottom +Mounting Hole 3.2mm, M3, DIN965 +mounting hole 3.2mm m3 din965 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_DIN965_Pad_TopOnly +Mounting Hole 3.2mm, M3, DIN965 +mounting hole 3.2mm m3 din965 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_ISO7380 +Mounting Hole 3.2mm, no annular, M3, ISO7380 +mounting hole 3.2mm no annular m3 iso7380 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_ISO7380_Pad +Mounting Hole 3.2mm, M3, ISO7380 +mounting hole 3.2mm m3 iso7380 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_ISO7380_Pad_TopBottom +Mounting Hole 3.2mm, M3, ISO7380 +mounting hole 3.2mm m3 iso7380 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_ISO7380_Pad_TopOnly +Mounting Hole 3.2mm, M3, ISO7380 +mounting hole 3.2mm m3 iso7380 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_ISO14580 +Mounting Hole 3.2mm, no annular, M3, ISO14580 +mounting hole 3.2mm no annular m3 iso14580 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_ISO14580_Pad +Mounting Hole 3.2mm, M3, ISO14580 +mounting hole 3.2mm m3 iso14580 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_ISO14580_Pad_TopBottom +Mounting Hole 3.2mm, M3, ISO14580 +mounting hole 3.2mm m3 iso14580 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_ISO14580_Pad_TopOnly +Mounting Hole 3.2mm, M3, ISO14580 +mounting hole 3.2mm m3 iso14580 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_Pad +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_Pad_TopBottom +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_Pad_TopOnly +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_Pad_Via +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +9 +1 +MountingHole +MountingHole_3.5mm +Mounting Hole 3.5mm, no annular +mounting hole 3.5mm no annular +0 +0 +0 +MountingHole +MountingHole_3.5mm_Pad +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +1 +1 +MountingHole +MountingHole_3.5mm_Pad_TopBottom +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +3 +1 +MountingHole +MountingHole_3.5mm_Pad_TopOnly +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +2 +1 +MountingHole +MountingHole_3.5mm_Pad_Via +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +9 +1 +MountingHole +MountingHole_3.7mm +Mounting Hole 3.7mm, no annular +mounting hole 3.7mm no annular +0 +0 +0 +MountingHole +MountingHole_3.7mm_Pad +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +1 +1 +MountingHole +MountingHole_3.7mm_Pad_TopBottom +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +3 +1 +MountingHole +MountingHole_3.7mm_Pad_TopOnly +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +2 +1 +MountingHole +MountingHole_3.7mm_Pad_Via +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +9 +1 +MountingHole +MountingHole_3mm +Mounting Hole 3mm, no annular +mounting hole 3mm no annular +0 +0 +0 +MountingHole +MountingHole_3mm_Pad +Mounting Hole 3mm +mounting hole 3mm +0 +1 +1 +MountingHole +MountingHole_3mm_Pad_TopBottom +Mounting Hole 3mm +mounting hole 3mm +0 +3 +1 +MountingHole +MountingHole_3mm_Pad_TopOnly +Mounting Hole 3mm +mounting hole 3mm +0 +2 +1 +MountingHole +MountingHole_3mm_Pad_Via +Mounting Hole 3mm +mounting hole 3mm +0 +9 +1 +MountingHole +MountingHole_4.3mm_M4 +Mounting Hole 4.3mm, no annular, M4 +mounting hole 4.3mm no annular m4 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_DIN965 +Mounting Hole 4.3mm, no annular, M4, DIN965 +mounting hole 4.3mm no annular m4 din965 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_DIN965_Pad +Mounting Hole 4.3mm, M4, DIN965 +mounting hole 4.3mm m4 din965 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_DIN965_Pad_TopBottom +Mounting Hole 4.3mm, M4, DIN965 +mounting hole 4.3mm m4 din965 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_DIN965_Pad_TopOnly +Mounting Hole 4.3mm, M4, DIN965 +mounting hole 4.3mm m4 din965 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_ISO7380 +Mounting Hole 4.3mm, no annular, M4, ISO7380 +mounting hole 4.3mm no annular m4 iso7380 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_ISO7380_Pad +Mounting Hole 4.3mm, M4, ISO7380 +mounting hole 4.3mm m4 iso7380 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_ISO7380_Pad_TopBottom +Mounting Hole 4.3mm, M4, ISO7380 +mounting hole 4.3mm m4 iso7380 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_ISO7380_Pad_TopOnly +Mounting Hole 4.3mm, M4, ISO7380 +mounting hole 4.3mm m4 iso7380 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_ISO14580 +Mounting Hole 4.3mm, no annular, M4, ISO14580 +mounting hole 4.3mm no annular m4 iso14580 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_ISO14580_Pad +Mounting Hole 4.3mm, M4, ISO14580 +mounting hole 4.3mm m4 iso14580 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_ISO14580_Pad_TopBottom +Mounting Hole 4.3mm, M4, ISO14580 +mounting hole 4.3mm m4 iso14580 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_ISO14580_Pad_TopOnly +Mounting Hole 4.3mm, M4, ISO14580 +mounting hole 4.3mm m4 iso14580 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_Pad +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_Pad_TopBottom +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_Pad_TopOnly +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_Pad_Via +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +9 +1 +MountingHole +MountingHole_4.3x6.2mm_M4_Pad +Mounting Hole 4.3x6.2mm, M4 +mounting hole 4.3x6.2mm m4 +0 +1 +1 +MountingHole +MountingHole_4.3x6.2mm_M4_Pad_Via +Mounting Hole 4.3x6.2mm, M4 +mounting hole 4.3x6.2mm m4 +0 +17 +1 +MountingHole +MountingHole_4.5mm +Mounting Hole 4.5mm, no annular +mounting hole 4.5mm no annular +0 +0 +0 +MountingHole +MountingHole_4.5mm_Pad +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +1 +1 +MountingHole +MountingHole_4.5mm_Pad_TopBottom +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +3 +1 +MountingHole +MountingHole_4.5mm_Pad_TopOnly +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +2 +1 +MountingHole +MountingHole_4.5mm_Pad_Via +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +9 +1 +MountingHole +MountingHole_4mm +Mounting Hole 4mm, no annular +mounting hole 4mm no annular +0 +0 +0 +MountingHole +MountingHole_4mm_Pad +Mounting Hole 4mm +mounting hole 4mm +0 +1 +1 +MountingHole +MountingHole_4mm_Pad_TopBottom +Mounting Hole 4mm +mounting hole 4mm +0 +3 +1 +MountingHole +MountingHole_4mm_Pad_TopOnly +Mounting Hole 4mm +mounting hole 4mm +0 +2 +1 +MountingHole +MountingHole_4mm_Pad_Via +Mounting Hole 4mm +mounting hole 4mm +0 +9 +1 +MountingHole +MountingHole_5.3mm_M5 +Mounting Hole 5.3mm, no annular, M5 +mounting hole 5.3mm no annular m5 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_DIN965 +Mounting Hole 5.3mm, no annular, M5, DIN965 +mounting hole 5.3mm no annular m5 din965 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_DIN965_Pad +Mounting Hole 5.3mm, M5, DIN965 +mounting hole 5.3mm m5 din965 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_DIN965_Pad_TopBottom +Mounting Hole 5.3mm, M5, DIN965 +mounting hole 5.3mm m5 din965 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_DIN965_Pad_TopOnly +Mounting Hole 5.3mm, M5, DIN965 +mounting hole 5.3mm m5 din965 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_ISO7380 +Mounting Hole 5.3mm, no annular, M5, ISO7380 +mounting hole 5.3mm no annular m5 iso7380 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_ISO7380_Pad +Mounting Hole 5.3mm, M5, ISO7380 +mounting hole 5.3mm m5 iso7380 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_ISO7380_Pad_TopBottom +Mounting Hole 5.3mm, M5, ISO7380 +mounting hole 5.3mm m5 iso7380 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_ISO7380_Pad_TopOnly +Mounting Hole 5.3mm, M5, ISO7380 +mounting hole 5.3mm m5 iso7380 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_ISO14580 +Mounting Hole 5.3mm, no annular, M5, ISO14580 +mounting hole 5.3mm no annular m5 iso14580 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_ISO14580_Pad +Mounting Hole 5.3mm, M5, ISO14580 +mounting hole 5.3mm m5 iso14580 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_ISO14580_Pad_TopBottom +Mounting Hole 5.3mm, M5, ISO14580 +mounting hole 5.3mm m5 iso14580 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_ISO14580_Pad_TopOnly +Mounting Hole 5.3mm, M5, ISO14580 +mounting hole 5.3mm m5 iso14580 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_Pad +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_Pad_TopBottom +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_Pad_TopOnly +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_Pad_Via +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +9 +1 +MountingHole +MountingHole_5.5mm +Mounting Hole 5.5mm, no annular +mounting hole 5.5mm no annular +0 +0 +0 +MountingHole +MountingHole_5.5mm_Pad +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +1 +1 +MountingHole +MountingHole_5.5mm_Pad_TopBottom +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +3 +1 +MountingHole +MountingHole_5.5mm_Pad_TopOnly +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +2 +1 +MountingHole +MountingHole_5.5mm_Pad_Via +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +9 +1 +MountingHole +MountingHole_5mm +Mounting Hole 5mm, no annular +mounting hole 5mm no annular +0 +0 +0 +MountingHole +MountingHole_5mm_Pad +Mounting Hole 5mm +mounting hole 5mm +0 +1 +1 +MountingHole +MountingHole_5mm_Pad_TopBottom +Mounting Hole 5mm +mounting hole 5mm +0 +3 +1 +MountingHole +MountingHole_5mm_Pad_TopOnly +Mounting Hole 5mm +mounting hole 5mm +0 +2 +1 +MountingHole +MountingHole_5mm_Pad_Via +Mounting Hole 5mm +mounting hole 5mm +0 +9 +1 +MountingHole +MountingHole_6.4mm_M6 +Mounting Hole 6.4mm, no annular, M6 +mounting hole 6.4mm no annular m6 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_DIN965 +Mounting Hole 6.4mm, no annular, M6, DIN965 +mounting hole 6.4mm no annular m6 din965 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_DIN965_Pad +Mounting Hole 6.4mm, M6, DIN965 +mounting hole 6.4mm m6 din965 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_DIN965_Pad_TopBottom +Mounting Hole 6.4mm, M6, DIN965 +mounting hole 6.4mm m6 din965 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_DIN965_Pad_TopOnly +Mounting Hole 6.4mm, M6, DIN965 +mounting hole 6.4mm m6 din965 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_ISO7380 +Mounting Hole 6.4mm, no annular, M6, ISO7380 +mounting hole 6.4mm no annular m6 iso7380 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_ISO7380_Pad +Mounting Hole 6.4mm, M6, ISO7380 +mounting hole 6.4mm m6 iso7380 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_ISO7380_Pad_TopBottom +Mounting Hole 6.4mm, M6, ISO7380 +mounting hole 6.4mm m6 iso7380 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_ISO7380_Pad_TopOnly +Mounting Hole 6.4mm, M6, ISO7380 +mounting hole 6.4mm m6 iso7380 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_ISO14580 +Mounting Hole 6.4mm, no annular, M6, ISO14580 +mounting hole 6.4mm no annular m6 iso14580 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_ISO14580_Pad +Mounting Hole 6.4mm, M6, ISO14580 +mounting hole 6.4mm m6 iso14580 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_ISO14580_Pad_TopBottom +Mounting Hole 6.4mm, M6, ISO14580 +mounting hole 6.4mm m6 iso14580 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_ISO14580_Pad_TopOnly +Mounting Hole 6.4mm, M6, ISO14580 +mounting hole 6.4mm m6 iso14580 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_Pad +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_Pad_TopBottom +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_Pad_TopOnly +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_Pad_Via +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +9 +1 +MountingHole +MountingHole_6.5mm +Mounting Hole 6.5mm, no annular +mounting hole 6.5mm no annular +0 +0 +0 +MountingHole +MountingHole_6.5mm_Pad +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +1 +1 +MountingHole +MountingHole_6.5mm_Pad_TopBottom +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +3 +1 +MountingHole +MountingHole_6.5mm_Pad_TopOnly +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +2 +1 +MountingHole +MountingHole_6.5mm_Pad_Via +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +9 +1 +MountingHole +MountingHole_6mm +Mounting Hole 6mm, no annular +mounting hole 6mm no annular +0 +0 +0 +MountingHole +MountingHole_6mm_Pad +Mounting Hole 6mm +mounting hole 6mm +0 +1 +1 +MountingHole +MountingHole_6mm_Pad_TopBottom +Mounting Hole 6mm +mounting hole 6mm +0 +3 +1 +MountingHole +MountingHole_6mm_Pad_TopOnly +Mounting Hole 6mm +mounting hole 6mm +0 +2 +1 +MountingHole +MountingHole_6mm_Pad_Via +Mounting Hole 6mm +mounting hole 6mm +0 +9 +1 +MountingHole +MountingHole_8.4mm_M8 +Mounting Hole 8.4mm, no annular, M8 +mounting hole 8.4mm no annular m8 +0 +0 +0 +MountingHole +MountingHole_8.4mm_M8_Pad +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +1 +1 +MountingHole +MountingHole_8.4mm_M8_Pad_TopBottom +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +3 +1 +MountingHole +MountingHole_8.4mm_M8_Pad_TopOnly +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +2 +1 +MountingHole +MountingHole_8.4mm_M8_Pad_Via +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +9 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H5mm_9771050360 +Mounting Hardware, external M3, height 5, Wuerth electronics 9771050360 (https://katalog.we-online.com/em/datasheet/9771050360.pdf), generated with kicad-footprint-generator +Mounting M3 9771050360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H6mm_9771060360 +Mounting Hardware, external M3, height 6, Wuerth electronics 9771060360 (https://katalog.we-online.com/em/datasheet/9771060360.pdf), generated with kicad-footprint-generator +Mounting M3 9771060360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H7mm_9771070360 +Mounting Hardware, external M3, height 7, Wuerth electronics 9771070360 (https://katalog.we-online.com/em/datasheet/9771070360.pdf), generated with kicad-footprint-generator +Mounting M3 9771070360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H8mm_9771080360 +Mounting Hardware, external M3, height 8, Wuerth electronics 9771080360 (https://katalog.we-online.com/em/datasheet/9771080360.pdf), generated with kicad-footprint-generator +Mounting M3 9771080360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H9mm_9771090360 +Mounting Hardware, external M3, height 9, Wuerth electronics 9771090360 (https://katalog.we-online.com/em/datasheet/9771090360.pdf), generated with kicad-footprint-generator +Mounting M3 9771090360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H10mm_9771100360 +Mounting Hardware, external M3, height 10, Wuerth electronics 9771100360 (https://katalog.we-online.com/em/datasheet/9771100360.pdf), generated with kicad-footprint-generator +Mounting M3 9771100360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H11mm_9771110360 +Mounting Hardware, external M3, height 11, Wuerth electronics 9771110360 (https://katalog.we-online.com/em/datasheet/9771110360.pdf), generated with kicad-footprint-generator +Mounting M3 9771110360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H12mm_9771120360 +Mounting Hardware, external M3, height 12, Wuerth electronics 9771120360 (https://katalog.we-online.com/em/datasheet/9771120360.pdf), generated with kicad-footprint-generator +Mounting M3 9771120360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H13mm_9771130360 +Mounting Hardware, external M3, height 13, Wuerth electronics 9771130360 (https://katalog.we-online.com/em/datasheet/9771130360.pdf), generated with kicad-footprint-generator +Mounting M3 9771130360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H14mm_9771140360 +Mounting Hardware, external M3, height 14, Wuerth electronics 9771140360 (https://katalog.we-online.com/em/datasheet/9771140360.pdf), generated with kicad-footprint-generator +Mounting M3 9771140360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H15mm_9771150360 +Mounting Hardware, external M3, height 15, Wuerth electronics 9771150360 (https://katalog.we-online.com/em/datasheet/9771150360.pdf), generated with kicad-footprint-generator +Mounting M3 9771150360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H1mm_9774010482 +Mounting Hardware, inside through hole 4.5mm, height 1, Wuerth electronics 9774010482 (https://katalog.we-online.de/em/datasheet/9774010482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774010482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H2mm_9774020482 +Mounting Hardware, inside through hole 4.5mm, height 2, Wuerth electronics 9774020482 (https://katalog.we-online.de/em/datasheet/9774020482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774020482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H3mm_9774030482 +Mounting Hardware, inside through hole 4.5mm, height 3, Wuerth electronics 9774030482 (https://katalog.we-online.de/em/datasheet/9774030482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774030482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H4mm_9774040482 +Mounting Hardware, inside through hole 4.5mm, height 4, Wuerth electronics 9774040482 (https://katalog.we-online.de/em/datasheet/9774040482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774040482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H5mm_9774050482 +Mounting Hardware, inside through hole 4.5mm, height 5, Wuerth electronics 9774050482 (https://katalog.we-online.de/em/datasheet/9774050482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774050482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H6mm_9774060482 +Mounting Hardware, inside through hole 4.5mm, height 6, Wuerth electronics 9774060482 (https://katalog.we-online.de/em/datasheet/9774060482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774060482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H7mm_9774070482 +Mounting Hardware, inside through hole 4.5mm, height 7, Wuerth electronics 9774070482 (https://katalog.we-online.de/em/datasheet/9774070482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774070482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H8mm_9774080482 +Mounting Hardware, inside through hole 4.5mm, height 8, Wuerth electronics 9774080482 (https://katalog.we-online.de/em/datasheet/9774080482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774080482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H9mm_9774090482 +Mounting Hardware, inside through hole 4.5mm, height 9, Wuerth electronics 9774090482 (https://katalog.we-online.de/em/datasheet/9774090482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774090482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H10mm_9774100482 +Mounting Hardware, inside through hole 4.5mm, height 10, Wuerth electronics 9774100482 (https://katalog.we-online.de/em/datasheet/9774100482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774100482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H1.5mm_9774015633 +Mounting Hardware, inside through hole M1.6, height 1.5, Wuerth electronics 9774015633 (https://katalog.we-online.com/em/datasheet/9774015633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774015633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H1mm_9774010633 +Mounting Hardware, inside through hole M1.6, height 1, Wuerth electronics 9774010633 (https://katalog.we-online.com/em/datasheet/9774010633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774010633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2.5mm_9774025633 +Mounting Hardware, inside through hole M1.6, height 2.5, Wuerth electronics 9774025633 (https://katalog.we-online.com/em/datasheet/9774025633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774025633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2.5mm_ThreadDepth1.5mm_97730256332 +Mounting Hardware, inside blind hole M1.6, height 2.5, Wuerth electronics 97730256332 (https://katalog.we-online.com/em/datasheet/97730256332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730256332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2.5mm_ThreadDepth1.5mm_NoNPTH_97730256330 +Mounting Hardware, inside blind hole M1.6, height 2.5, Wuerth electronics 97730256330 (https://katalog.we-online.com/em/datasheet/97730256330R.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730256330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2mm_9774020633 +Mounting Hardware, inside through hole M1.6, height 2, Wuerth electronics 9774020633 (https://katalog.we-online.com/em/datasheet/9774020633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774020633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3.5mm_ThreadDepth2mm_97730356332 +Mounting Hardware, inside blind hole M1.6, height 3.5, Wuerth electronics 97730356332 (https://katalog.we-online.com/em/datasheet/97730356332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730356332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3.5mm_ThreadDepth2mm_97730356334 +Mounting Hardware, inside blind hole M1.6, height 3.5, Wuerth electronics 97730356334 (https://katalog.we-online.com/em/datasheet/97730356334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730356334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3.5mm_ThreadDepth2mm_NoNPTH_97730356330 +Mounting Hardware, inside blind hole M1.6, height 3.5, Wuerth electronics 97730356330 (https://katalog.we-online.com/em/datasheet/97730356330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730356330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3mm_9774030633 +Mounting Hardware, inside through hole M1.6, height 3, Wuerth electronics 9774030633 (https://katalog.we-online.com/em/datasheet/9774030633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774030633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3mm_ThreadDepth1.8mm_97730306332 +Mounting Hardware, inside blind hole M1.6, height 3, Wuerth electronics 97730306332 (https://katalog.we-online.com/em/datasheet/97730306332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730306332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3mm_ThreadDepth1.8mm_NoNPTH_97730306330 +Mounting Hardware, inside blind hole M1.6, height 3, Wuerth electronics 97730306330 (https://katalog.we-online.com/em/datasheet/97730306330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730306330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4.5mm_ThreadDepth2mm_97730456332 +Mounting Hardware, inside blind hole M1.6, height 4.5, Wuerth electronics 97730456332 (https://katalog.we-online.com/em/datasheet/97730456332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730456332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4.5mm_ThreadDepth2mm_97730456334 +Mounting Hardware, inside blind hole M1.6, height 4.5, Wuerth electronics 97730456334 (https://katalog.we-online.com/em/datasheet/97730456334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730456334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4.5mm_ThreadDepth2mm_NoNPTH_97730456330 +Mounting Hardware, inside blind hole M1.6, height 4.5, Wuerth electronics 97730456330 (https://katalog.we-online.com/em/datasheet/97730456330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730456330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4mm_ThreadDepth2mm_97730406332 +Mounting Hardware, inside blind hole M1.6, height 4, Wuerth electronics 97730406332 (https://katalog.we-online.com/em/datasheet/97730406332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730406332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4mm_ThreadDepth2mm_97730406334 +Mounting Hardware, inside blind hole M1.6, height 4, Wuerth electronics 97730406334 (https://katalog.we-online.com/em/datasheet/97730406334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730406334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4mm_ThreadDepth2mm_NoNPTH_97730406330 +Mounting Hardware, inside blind hole M1.6, height 4, Wuerth electronics 97730406330 (https://katalog.we-online.com/em/datasheet/97730406330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730406330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H5mm_ThreadDepth2mm_97730506332 +Mounting Hardware, inside blind hole M1.6, height 5, Wuerth electronics 97730506332 (https://katalog.we-online.com/em/datasheet/97730506332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730506332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H5mm_ThreadDepth2mm_97730506334 +Mounting Hardware, inside blind hole M1.6, height 5, Wuerth electronics 97730506334 (https://katalog.we-online.com/em/datasheet/97730506334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730506334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H5mm_ThreadDepth2mm_NoNPTH_97730506330 +Mounting Hardware, inside blind hole M1.6, height 5, Wuerth electronics 97730506330 (https://katalog.we-online.com/em/datasheet/97730506330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730506330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H6mm_ThreadDepth2mm_97730606332 +Mounting Hardware, inside blind hole M1.6, height 6, Wuerth electronics 97730606332 (https://katalog.we-online.com/em/datasheet/97730606332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730606332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H6mm_ThreadDepth2mm_97730606334 +Mounting Hardware, inside blind hole M1.6, height 6, Wuerth electronics 97730606334 (https://katalog.we-online.com/em/datasheet/97730606334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730606334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H6mm_ThreadDepth2mm_NoNPTH_97730606330 +Mounting Hardware, inside blind hole M1.6, height 6, Wuerth electronics 97730606330 (https://katalog.we-online.com/em/datasheet/97730606330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730606330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H1.5mm_9774015243 +Mounting Hardware, inside through hole M2, height 1.5, Wuerth electronics 9774015243 (https://katalog.we-online.de/em/datasheet/9774015243.pdf), generated with kicad-footprint-generator +Mounting M2 9774015243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H1mm_9774010243 +Mounting Hardware, inside through hole M2, height 1, Wuerth electronics 9774010243 (https://katalog.we-online.de/em/datasheet/9774010243.pdf), generated with kicad-footprint-generator +Mounting M2 9774010243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H2.5mm_9774025243 +Mounting Hardware, inside through hole M2, height 2.5, Wuerth electronics 9774025243 (https://katalog.we-online.de/em/datasheet/9774025243.pdf), generated with kicad-footprint-generator +Mounting M2 9774025243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H2mm_9774020243 +Mounting Hardware, inside through hole M2, height 2, Wuerth electronics 9774020243 (https://katalog.we-online.de/em/datasheet/9774020243.pdf), generated with kicad-footprint-generator +Mounting M2 9774020243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H3.5mm_9774035243 +Mounting Hardware, inside through hole M2, height 3.5, Wuerth electronics 9774035243 (https://katalog.we-online.de/em/datasheet/9774035243.pdf), generated with kicad-footprint-generator +Mounting M2 9774035243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H3mm_9774030243 +Mounting Hardware, inside through hole M2, height 3, Wuerth electronics 9774030243 (https://katalog.we-online.de/em/datasheet/9774030243.pdf), generated with kicad-footprint-generator +Mounting M2 9774030243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H4.5mm_9774045243 +Mounting Hardware, inside through hole M2, height 4.5, Wuerth electronics 9774045243 (https://katalog.we-online.de/em/datasheet/9774045243.pdf), generated with kicad-footprint-generator +Mounting M2 9774045243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H4mm_9774040243 +Mounting Hardware, inside through hole M2, height 4, Wuerth electronics 9774040243 (https://katalog.we-online.de/em/datasheet/9774040243.pdf), generated with kicad-footprint-generator +Mounting M2 9774040243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H5mm_9774050243 +Mounting Hardware, inside through hole M2, height 5, Wuerth electronics 9774050243 (https://katalog.we-online.de/em/datasheet/9774050243.pdf), generated with kicad-footprint-generator +Mounting M2 9774050243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H6mm_9774060243 +Mounting Hardware, inside through hole M2, height 6, Wuerth electronics 9774060243 (https://katalog.we-online.de/em/datasheet/9774060243.pdf), generated with kicad-footprint-generator +Mounting M2 9774060243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H7mm_9774070243 +Mounting Hardware, inside through hole M2, height 7, Wuerth electronics 9774070243 (https://katalog.we-online.de/em/datasheet/9774070243.pdf), generated with kicad-footprint-generator +Mounting M2 9774070243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H8mm_9774080243 +Mounting Hardware, inside through hole M2, height 8, Wuerth electronics 9774080243 (https://katalog.we-online.de/em/datasheet/9774080243.pdf), generated with kicad-footprint-generator +Mounting M2 9774080243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H1.5mm_9774015360 +Mounting Hardware, inside through hole M3, height 1.5, Wuerth electronics 9774015360 (https://katalog.we-online.de/em/datasheet/9774015360.pdf), generated with kicad-footprint-generator +Mounting M3 9774015360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H1mm_9774010360 +Mounting Hardware, inside through hole M3, height 1, Wuerth electronics 9774010360 (https://katalog.we-online.de/em/datasheet/9774010360.pdf), generated with kicad-footprint-generator +Mounting M3 9774010360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H2.5mm_9774025360 +Mounting Hardware, inside through hole M3, height 2.5, Wuerth electronics 9774025360 (https://katalog.we-online.de/em/datasheet/9774025360.pdf), generated with kicad-footprint-generator +Mounting M3 9774025360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H2mm_9774020360 +Mounting Hardware, inside through hole M3, height 2, Wuerth electronics 9774020360 (https://katalog.we-online.de/em/datasheet/9774020360.pdf), generated with kicad-footprint-generator +Mounting M3 9774020360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H3mm_9774030360 +Mounting Hardware, inside through hole M3, height 3, Wuerth electronics 9774030360 (https://katalog.we-online.de/em/datasheet/9774030360R.pdf), generated with kicad-footprint-generator +Mounting M3 9774030360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H4mm_9774040360 +Mounting Hardware, inside through hole M3, height 4, Wuerth electronics 9774040360 (https://katalog.we-online.de/em/datasheet/9774040360.pdf), generated with kicad-footprint-generator +Mounting M3 9774040360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H5mm_9774050360 +Mounting Hardware, inside through hole M3, height 5, Wuerth electronics 9774050360 (https://katalog.we-online.de/em/datasheet/9774050360.pdf), generated with kicad-footprint-generator +Mounting M3 9774050360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H6mm_9774060360 +Mounting Hardware, inside through hole M3, height 6, Wuerth electronics 9774060360 (https://katalog.we-online.de/em/datasheet/9774060360.pdf), generated with kicad-footprint-generator +Mounting M3 9774060360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H7mm_9774070360 +Mounting Hardware, inside through hole M3, height 7, Wuerth electronics 9774070360 (https://katalog.we-online.de/em/datasheet/9774070360.pdf), generated with kicad-footprint-generator +Mounting M3 9774070360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H8mm_9774080360 +Mounting Hardware, inside through hole M3, height 8, Wuerth electronics 9774080360 (https://katalog.we-online.de/em/datasheet/9774080360.pdf), generated with kicad-footprint-generator +Mounting M3 9774080360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H9mm_9774090360 +Mounting Hardware, inside through hole M3, height 9, Wuerth electronics 9774090360 (https://katalog.we-online.de/em/datasheet/9774090360.pdf), generated with kicad-footprint-generator +Mounting M3 9774090360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H10mm_9774100360 +Mounting Hardware, inside through hole M3, height 10, Wuerth electronics 9774100360 (https://katalog.we-online.de/em/datasheet/9774100360.pdf), generated with kicad-footprint-generator +Mounting M3 9774100360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H11mm_9774110360 +Mounting Hardware, inside through hole M3, height 11, Wuerth electronics 9774110360 (https://katalog.we-online.de/em/datasheet/9774110360.pdf), generated with kicad-footprint-generator +Mounting M3 9774110360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H12mm_9774120360 +Mounting Hardware, inside through hole M3, height 12, Wuerth electronics 9774120360 (https://katalog.we-online.de/em/datasheet/9774120360.pdf), generated with kicad-footprint-generator +Mounting M3 9774120360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H13mm_9774130360 +Mounting Hardware, inside through hole M3, height 13, Wuerth electronics 9774130360 (https://katalog.we-online.de/em/datasheet/9774130360.pdf), generated with kicad-footprint-generator +Mounting M3 9774130360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H14mm_9774140360 +Mounting Hardware, inside through hole M3, height 14, Wuerth electronics 9774140360 (https://katalog.we-online.de/em/datasheet/9774140360.pdf), generated with kicad-footprint-generator +Mounting M3 9774140360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H15mm_9774150360 +Mounting Hardware, inside through hole M3, height 15, Wuerth electronics 9774150360 (https://katalog.we-online.de/em/datasheet/9774150360.pdf), generated with kicad-footprint-generator +Mounting M3 9774150360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H2.6mm_ReverseMount_9775026960 +Mounting Hardware, inside through hole 3.2mm, height 2.6, Wuerth electronics 9775026960 (https://katalog.we-online.com/em/datasheet/9775026960R.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775026960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H3.1mm_ReverseMount_9775031960 +Mounting Hardware, inside through hole 3.2mm, height 3.1, Wuerth electronics 9775031960 (https://katalog.we-online.com/em/datasheet/9775031960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775031960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H3.6mm_ReverseMount_9775036960 +Mounting Hardware, inside through hole 3.2mm, height 3.6, Wuerth electronics 9775036960 (https://katalog.we-online.com/em/datasheet/9775036960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775036960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H4.1mm_ReverseMount_9775041960 +Mounting Hardware, inside through hole 3.2mm, height 4.1, Wuerth electronics 9775041960 (https://katalog.we-online.com/em/datasheet/9775041960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775041960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H4.6mm_ReverseMount_9775046960 +Mounting Hardware, inside through hole 3.2mm, height 4.6, Wuerth electronics 9775046960 (https://katalog.we-online.com/em/datasheet/9775046960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775046960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H5.1mm_ReverseMount_9775051960 +Mounting Hardware, inside through hole 3.2mm, height 5.1, Wuerth electronics 9775051960 (https://katalog.we-online.com/em/datasheet/9775051960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775051960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H5.6mm_ReverseMount_9775056960 +Mounting Hardware, inside through hole 3.2mm, height 5.6, Wuerth electronics 9775056960 (https://katalog.we-online.com/em/datasheet/9775056960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775056960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H6.6mm_ReverseMount_9775066960 +Mounting Hardware, inside through hole 3.2mm, height 6.6, Wuerth electronics 9775066960 (https://katalog.we-online.com/em/datasheet/9775066960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775066960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H7.6mm_ReverseMount_9775076960 +Mounting Hardware, inside through hole 3.2mm, height 7.6, Wuerth electronics 9775076960 (https://katalog.we-online.com/em/datasheet/9775076960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775076960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H8.6mm_ReverseMount_9775086960 +Mounting Hardware, inside through hole 3.2mm, height 8.6, Wuerth electronics 9775086960 (https://katalog.we-online.com/em/datasheet/9775086960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775086960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H9.6mm_ReverseMount_9775096960 +Mounting Hardware, inside through hole 3.2mm, height 9.6, Wuerth electronics 9775096960 (https://katalog.we-online.com/em/datasheet/9775096960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775096960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H10.6mm_ReverseMount_9775106960 +Mounting Hardware, inside through hole 3.2mm, height 10.6, Wuerth electronics 9775106960 (https://katalog.we-online.com/em/datasheet/9775106960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775106960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H11.6mm_ReverseMount_9775116960 +Mounting Hardware, inside through hole 3.2mm, height 11.6, Wuerth electronics 9775116960 (https://katalog.we-online.com/em/datasheet/9775116960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775116960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H2.6mm_ReverseMount_9775026360 +Mounting Hardware, inside through hole M3, height 2.6, Wuerth electronics 9775026360 (https://katalog.we-online.com/em/datasheet/9775026360.pdf), generated with kicad-footprint-generator +Mounting M3 9775026360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H3.1mm_ReverseMount_9775031360 +Mounting Hardware, inside through hole M3, height 3.1, Wuerth electronics 9775031360 (https://katalog.we-online.com/em/datasheet/9775031360.pdf), generated with kicad-footprint-generator +Mounting M3 9775031360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H3.6mm_ReverseMount_9775036360 +Mounting Hardware, inside through hole M3, height 3.6, Wuerth electronics 9775036360 (https://katalog.we-online.com/em/datasheet/9775036360.pdf), generated with kicad-footprint-generator +Mounting M3 9775036360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H4.1mm_ReverseMount_9775041360 +Mounting Hardware, inside through hole M3, height 4.1, Wuerth electronics 9775041360 (https://katalog.we-online.com/em/datasheet/9775041360.pdf), generated with kicad-footprint-generator +Mounting M3 9775041360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H4.6mm_ReverseMount_9775046360 +Mounting Hardware, inside through hole M3, height 4.6, Wuerth electronics 9775046360 (https://katalog.we-online.com/em/datasheet/9775046360.pdf), generated with kicad-footprint-generator +Mounting M3 9775046360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H5.1mm_ReverseMount_9775051360 +Mounting Hardware, inside through hole M3, height 5.1, Wuerth electronics 9775051360 (https://katalog.we-online.com/em/datasheet/9775051360.pdf), generated with kicad-footprint-generator +Mounting M3 9775051360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H5.6mm_ReverseMount_9775056360 +Mounting Hardware, inside through hole M3, height 5.6, Wuerth electronics 9775056360 (https://katalog.we-online.com/em/datasheet/9775056360.pdf), generated with kicad-footprint-generator +Mounting M3 9775056360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H6.6mm_ReverseMount_9775066360 +Mounting Hardware, inside through hole M3, height 6.6, Wuerth electronics 9775066360 (https://katalog.we-online.com/em/datasheet/9775066360.pdf), generated with kicad-footprint-generator +Mounting M3 9775066360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H7.6mm_ReverseMount_9775076360 +Mounting Hardware, inside through hole M3, height 7.6, Wuerth electronics 9775076360 (https://katalog.we-online.com/em/datasheet/9775076360.pdf), generated with kicad-footprint-generator +Mounting M3 9775076360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H8.6mm_ReverseMount_9775086360 +Mounting Hardware, inside through hole M3, height 8.6, Wuerth electronics 9775086360 (https://katalog.we-online.com/em/datasheet/9775086360.pdf), generated with kicad-footprint-generator +Mounting M3 9775086360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H9.6mm_ReverseMount_9775096360 +Mounting Hardware, inside through hole M3, height 9.6, Wuerth electronics 9775096360 (https://katalog.we-online.com/em/datasheet/9775096360.pdf), generated with kicad-footprint-generator +Mounting M3 9775096360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H10.6mm_ReverseMount_9775106360 +Mounting Hardware, inside through hole M3, height 10.6, Wuerth electronics 9775106360 (https://katalog.we-online.com/em/datasheet/9775106360.pdf), generated with kicad-footprint-generator +Mounting M3 9775106360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H11.6mm_ReverseMount_9775116360 +Mounting Hardware, inside through hole M3, height 11.6, Wuerth electronics 9775116360 (https://katalog.we-online.com/em/datasheet/9775116360.pdf), generated with kicad-footprint-generator +Mounting M3 9775116360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H2.5mm_SnapRivet_9776025960 +Mounting Hardware, inside through hole 3.3mm, height 2.5, Wuerth electronics 9776025960 (https://katalog.we-online.com/em/datasheet/9776025960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776025960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H2mm_SnapRivet_9776020960 +Mounting Hardware, inside through hole 3.3mm, height 2, Wuerth electronics 9776020960 (https://katalog.we-online.com/em/datasheet/9776020960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776020960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H3mm_SnapRivet_9776030960 +Mounting Hardware, inside through hole 3.3mm, height 3, Wuerth electronics 9776030960 (https://katalog.we-online.com/em/datasheet/9776030960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776030960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H4mm_SnapRivet_9776040960 +Mounting Hardware, inside through hole 3.3mm, height 4, Wuerth electronics 9776040960 (https://katalog.we-online.com/em/datasheet/9776040960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776040960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H5mm_SnapRivet_9776050960 +Mounting Hardware, inside through hole 3.3mm, height 5, Wuerth electronics 9776050960 (https://katalog.we-online.com/em/datasheet/9776050960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776050960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H6mm_SnapRivet_9776060960 +Mounting Hardware, inside through hole 3.3mm, height 6, Wuerth electronics 9776060960 (https://katalog.we-online.com/em/datasheet/9776060960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776060960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H7mm_SnapRivet_9776070960 +Mounting Hardware, inside through hole 3.3mm, height 7, Wuerth electronics 9776070960 (https://katalog.we-online.com/em/datasheet/9776070960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776070960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H8mm_SnapRivet_9776080960 +Mounting Hardware, inside through hole 3.3mm, height 8, Wuerth electronics 9776080960 (https://katalog.we-online.com/em/datasheet/9776080960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776080960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H9mm_SnapRivet_9776090960 +Mounting Hardware, inside through hole 3.3mm, height 9, Wuerth electronics 9776090960 (https://katalog.we-online.com/em/datasheet/9776090960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776090960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H10mm_SnapRivet_9776100960 +Mounting Hardware, inside through hole 3.3mm, height 10, Wuerth electronics 9776100960 (https://katalog.we-online.com/em/datasheet/9776100960R.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776100960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H1.5mm_9774015951 +Mounting Hardware, inside through hole 2.7mm, height 1.5, Wuerth electronics 9774015951 (https://katalog.we-online.de/em/datasheet/9774015951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774015951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H1mm_9774010951 +Mounting Hardware, inside through hole 2.7mm, height 1, Wuerth electronics 9774010951 (https://katalog.we-online.de/em/datasheet/9774010951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774010951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H2.5mm_9774025951 +Mounting Hardware, inside through hole 2.7mm, height 2.5, Wuerth electronics 9774025951 (https://katalog.we-online.de/em/datasheet/9774025951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774025951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H2mm_9774020951 +Mounting Hardware, inside through hole 2.7mm, height 2, Wuerth electronics 9774020951 (https://katalog.we-online.de/em/datasheet/9774020951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774020951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H3mm_9774030951 +Mounting Hardware, inside through hole 2.7mm, height 3, Wuerth electronics 9774030951 (https://katalog.we-online.de/em/datasheet/9774030951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774030951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H4mm_9774040951 +Mounting Hardware, inside through hole 2.7mm, height 4, Wuerth electronics 9774040951 (https://katalog.we-online.de/em/datasheet/9774040951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774040951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H5.5mm_9774055951 +Mounting Hardware, inside through hole 2.7mm, height 5.5, Wuerth electronics 9774055951 (https://katalog.we-online.de/em/datasheet/9774055951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774055951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H5mm_9774050951 +Mounting Hardware, inside through hole 2.7mm, height 5, Wuerth electronics 9774050951 (https://katalog.we-online.de/em/datasheet/9774050951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774050951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H6.5mm_9774065951 +Mounting Hardware, inside through hole 2.7mm, height 6.5, Wuerth electronics 9774065951 (https://katalog.we-online.de/em/datasheet/9774065951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774065951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H6mm_9774060951 +Mounting Hardware, inside through hole 2.7mm, height 6, Wuerth electronics 9774060951 (https://katalog.we-online.de/em/datasheet/9774060951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774060951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H7mm_9774070951 +Mounting Hardware, inside through hole 2.7mm, height 7, Wuerth electronics 9774070951 (https://katalog.we-online.de/em/datasheet/9774070951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774070951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H8mm_9774080951 +Mounting Hardware, inside through hole 2.7mm, height 8, Wuerth electronics 9774080951 (https://katalog.we-online.de/em/datasheet/9774080951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774080951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H9mm_9774090951 +Mounting Hardware, inside through hole 2.7mm, height 9, Wuerth electronics 9774090951 (https://katalog.we-online.de/em/datasheet/9774090951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774090951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H10mm_9774100951 +Mounting Hardware, inside through hole 2.7mm, height 10, Wuerth electronics 9774100951 (https://katalog.we-online.de/em/datasheet/9774100951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774100951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H1.5mm_9774015943 +Mounting Hardware, inside through hole 2.25mm, height 1.5, Wuerth electronics 9774015943 (https://katalog.we-online.de/em/datasheet/9774015943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774015943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H1mm_9774010943 +Mounting Hardware, inside through hole 2.25mm, height 1, Wuerth electronics 9774010943 (https://katalog.we-online.de/em/datasheet/9774010943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774010943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H2.5mm_9774025943 +Mounting Hardware, inside through hole 2.25mm, height 2.5, Wuerth electronics 9774025943 (https://katalog.we-online.de/em/datasheet/9774025943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774025943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H2mm_9774020943 +Mounting Hardware, inside through hole 2.25mm, height 2, Wuerth electronics 9774020943 (https://katalog.we-online.de/em/datasheet/9774020943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774020943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H3.5mm_9774035943 +Mounting Hardware, inside through hole 2.25mm, height 3.5, Wuerth electronics 9774035943 (https://katalog.we-online.de/em/datasheet/9774035943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774035943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H3mm_9774030943 +Mounting Hardware, inside through hole 2.25mm, height 3, Wuerth electronics 9774030943 (https://katalog.we-online.de/em/datasheet/9774030943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774030943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H4.5mm_9774045943 +Mounting Hardware, inside through hole 2.25mm, height 4.5, Wuerth electronics 9774045943 (https://katalog.we-online.de/em/datasheet/9774045943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774045943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H4mm_9774040943 +Mounting Hardware, inside through hole 2.25mm, height 4, Wuerth electronics 9774040943 (https://katalog.we-online.de/em/datasheet/9774040943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774040943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H5mm_9774050943 +Mounting Hardware, inside through hole 2.25mm, height 5, Wuerth electronics 9774050943 (https://katalog.we-online.de/em/datasheet/9774050943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774050943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H6mm_9774060943 +Mounting Hardware, inside through hole 2.25mm, height 6, Wuerth electronics 9774060943 (https://katalog.we-online.de/em/datasheet/9774060943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774060943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H7mm_9774070943 +Mounting Hardware, inside through hole 2.25mm, height 7, Wuerth electronics 9774070943 (https://katalog.we-online.de/em/datasheet/9774070943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774070943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H8mm_9774080943 +Mounting Hardware, inside through hole 2.25mm, height 8, Wuerth electronics 9774080943 (https://katalog.we-online.de/em/datasheet/9774080943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774080943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H1.5mm_9774015960 +Mounting Hardware, inside through hole 3.3mm, height 1.5, Wuerth electronics 9774015960 (https://katalog.we-online.de/em/datasheet/9774015960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774015960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H1mm_9774010960 +Mounting Hardware, inside through hole 3.3mm, height 1, Wuerth electronics 9774010960 (https://katalog.we-online.de/em/datasheet/9774010960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774010960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H2.5mm_9774025960 +Mounting Hardware, inside through hole 3.3mm, height 2.5, Wuerth electronics 9774025960 (https://katalog.we-online.de/em/datasheet/9774025960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774025960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H2mm_9774020960 +Mounting Hardware, inside through hole 3.3mm, height 2, Wuerth electronics 9774020960 (https://katalog.we-online.de/em/datasheet/9774020960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774020960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H3mm_9774030960 +Mounting Hardware, inside through hole 3.3mm, height 3, Wuerth electronics 9774030960 (https://katalog.we-online.de/em/datasheet/9774030960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774030960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H4mm_9774040960 +Mounting Hardware, inside through hole 3.3mm, height 4, Wuerth electronics 9774040960 (https://katalog.we-online.de/em/datasheet/9774040960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774040960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H5mm_9774050960 +Mounting Hardware, inside through hole 3.3mm, height 5, Wuerth electronics 9774050960 (https://katalog.we-online.de/em/datasheet/9774050960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774050960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H6mm_9774060960 +Mounting Hardware, inside through hole 3.3mm, height 6, Wuerth electronics 9774060960 (https://katalog.we-online.de/em/datasheet/9774060960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774060960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H7mm_9774070960 +Mounting Hardware, inside through hole 3.3mm, height 7, Wuerth electronics 9774070960 (https://katalog.we-online.de/em/datasheet/9774070960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774070960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H8mm_9774080960 +Mounting Hardware, inside through hole 3.3mm, height 8, Wuerth electronics 9774080960 (https://katalog.we-online.de/em/datasheet/9774080960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774080960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H9mm_9774090960 +Mounting Hardware, inside through hole 3.3mm, height 9, Wuerth electronics 9774090960 (https://katalog.we-online.de/em/datasheet/9774090960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774090960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H10mm_9774100960 +Mounting Hardware, inside through hole 3.3mm, height 10, Wuerth electronics 9774100960 (https://katalog.we-online.de/em/datasheet/9774100960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774100960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H11mm_9774110960 +Mounting Hardware, inside through hole 3.3mm, height 11, Wuerth electronics 9774110960 (https://katalog.we-online.de/em/datasheet/9774110960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774110960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H12mm_9774120960 +Mounting Hardware, inside through hole 3.3mm, height 12, Wuerth electronics 9774120960 (https://katalog.we-online.de/em/datasheet/9774120960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774120960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H13mm_9774130960 +Mounting Hardware, inside through hole 3.3mm, height 13, Wuerth electronics 9774130960 (https://katalog.we-online.de/em/datasheet/9774130960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774130960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H14mm_9774140960 +Mounting Hardware, inside through hole 3.3mm, height 14, Wuerth electronics 9774140960 (https://katalog.we-online.de/em/datasheet/9774140960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774140960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H15mm_9774150960 +Mounting Hardware, inside through hole 3.3mm, height 15, Wuerth electronics 9774150960 (https://katalog.we-online.de/em/datasheet/9774150960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774150960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H1mm_9774010982 +Mounting Hardware, inside through hole 4.5mm, height 1, Wuerth electronics 9774010982 (https://katalog.we-online.de/em/datasheet/9774010982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774010982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H2mm_9774020982 +Mounting Hardware, inside through hole 4.5mm, height 2, Wuerth electronics 9774020982 (https://katalog.we-online.de/em/datasheet/9774020982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774020982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H3mm_9774030982 +Mounting Hardware, inside through hole 4.5mm, height 3, Wuerth electronics 9774030982 (https://katalog.we-online.de/em/datasheet/9774030982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774030982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H4mm_9774040982 +Mounting Hardware, inside through hole 4.5mm, height 4, Wuerth electronics 9774040982 (https://katalog.we-online.de/em/datasheet/9774040982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774040982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H5mm_9774050982 +Mounting Hardware, inside through hole 4.5mm, height 5, Wuerth electronics 9774050982 (https://katalog.we-online.de/em/datasheet/9774050982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774050982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H6mm_9774060982 +Mounting Hardware, inside through hole 4.5mm, height 6, Wuerth electronics 9774060982 (https://katalog.we-online.de/em/datasheet/9774060982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774060982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H7mm_9774070982 +Mounting Hardware, inside through hole 4.5mm, height 7, Wuerth electronics 9774070982 (https://katalog.we-online.de/em/datasheet/9774070982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774070982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H8mm_9774080982 +Mounting Hardware, inside through hole 4.5mm, height 8, Wuerth electronics 9774080982 (https://katalog.we-online.de/em/datasheet/9774080982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774080982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H9mm_9774090982 +Mounting Hardware, inside through hole 4.5mm, height 9, Wuerth electronics 9774090982 (https://katalog.we-online.de/em/datasheet/9774090982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774090982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H10mm_9774100982 +Mounting Hardware, inside through hole 4.5mm, height 10, Wuerth electronics 9774100982 (https://katalog.we-online.de/em/datasheet/9774100982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774100982 +0 +8 +1 +NetTie +NetTie-2_SMD_Pad0.5mm +Net tie, 2 pin, 0.5mm square SMD pads +net tie +0 +2 +2 +NetTie +NetTie-2_SMD_Pad2.0mm +Net tie, 2 pin, 2.0mm square SMD pads +net tie +0 +2 +2 +NetTie +NetTie-2_THT_Pad0.3mm +Net tie, 2 pin, 0.3mm round THT pads +net tie +0 +2 +2 +NetTie +NetTie-2_THT_Pad1.0mm +Net tie, 2 pin, 1.0mm round THT pads +net tie +0 +2 +2 +NetTie +NetTie-3_SMD_Pad0.5mm +Net tie, 3 pin, 0.5mm square SMD pads +net tie +0 +3 +3 +NetTie +NetTie-3_SMD_Pad2.0mm +Net tie, 3 pin, 2.0mm square SMD pads +net tie +0 +3 +3 +NetTie +NetTie-3_THT_Pad0.3mm +Net tie, 3 pin, 0.3mm round THT pads +net tie +0 +3 +3 +NetTie +NetTie-3_THT_Pad1.0mm +Net tie, 3 pin, 1.0mm round THT pads +net tie +0 +3 +3 +NetTie +NetTie-4_SMD_Pad0.5mm +Net tie, 4 pin, 0.5mm square SMD pads +net tie +0 +4 +4 +NetTie +NetTie-4_SMD_Pad2.0mm +Net tie, 4 pin, 2.0mm square SMD pads +net tie +0 +4 +4 +NetTie +NetTie-4_THT_Pad0.3mm +Net tie, 4 pin, 0.3mm round THT pads +net tie +0 +4 +4 +NetTie +NetTie-4_THT_Pad1.0mm +Net tie, 4 pin, 1.0mm round THT pads +net tie +0 +4 +4 +OptoDevice +ADNS-9800 +Laser Gaming Sensor ADNS-9800 +MOUSE MOUSE_SENSOR LASER_GAMING_SENSOR +0 +16 +16 +OptoDevice +AGILENT_HFBR-152x +Fiberoptic Transmitter TX, HFBR series (https://docs.broadcom.com/docs/AV02-3283EN) +Fiberoptic Transmitter +0 +6 +6 +OptoDevice +AGILENT_HFBR-252x +Fiberoptic Receiver RX, HFBR series (https://docs.broadcom.com/docs/AV02-3283EN) +Fiberoptic Transmitter +0 +6 +6 +OptoDevice +AMS_TSL2550_SMD +http://ams.com/eng/content/download/250130/975613/142977 +TSL2550 ambient light sensor +0 +4 +4 +OptoDevice +Broadcom_AFBR-16xxZ_Horizontal +Fiber Optic Transmitter and Receiver, https://docs.broadcom.com/docs/AV02-4369EN +Fiber Optic Transmitter and Receiver +0 +6 +6 +OptoDevice +Broadcom_AFBR-16xxZ_Tilted +Fiber Optic Transmitter and Receiver, https://docs.broadcom.com/docs/AV02-4369EN +Fiber Optic Transmitter and Receiver +0 +6 +6 +OptoDevice +Broadcom_AFBR-16xxZ_Vertical +Fiber Optic Transmitter and Receiver, https://docs.broadcom.com/docs/AV02-4369EN +Fiber Optic Transmitter and Receiver +0 +6 +6 +OptoDevice +Broadcom_APDS-9301 +ambient light sensor, i2c interface, 6-pin chipled package, https://docs.broadcom.com/docs/AV02-2315EN +ambient light sensor chipled +0 +6 +6 +OptoDevice +Broadcom_DFN-6_2x2mm_P0.65mm +Broadcom DFN, 6 Pin (https://docs.broadcom.com/docs/AV02-4755EN), generated with kicad-footprint-generator ipc_noLead_generator.py +Broadcom DFN NoLead +0 +6 +6 +OptoDevice +Broadcom_LGA-8_2x2mm_P0.53mm +Broadcom LGA, 8 Pin (https://docs.broadcom.com/docs/AV02-4755EN), generated with kicad-footprint-generator ipc_noLead_generator.py +Broadcom LGA NoLead +0 +8 +8 +OptoDevice +Everlight_ITR1201SR10AR +package for Everlight ITR1201SR10AR, light-direction upwards, see https://www.everlight.com/file/ProductFile/ITR1201SR10AR-TR.pdf +reflective opto couple photo coupler +0 +4 +4 +OptoDevice +Everlight_ITR8307 +package for Everlight ITR8307 with PCB cutout, light-direction upwards, see http://www.everlight.com/file/ProductFile/ITR8307.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Everlight_ITR8307F43 +package for Everlight ITR8307/F43, see https://everlighteurope.com/index.php?controller=attachment&id_attachment=5385 +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Everlight_ITR8307_Reverse +package for Everlight ITR8307 with PCB cutout, light-direction downwards, see http://www.everlight.com/file/ProductFile/ITR8307.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Finder_34.81 +Relay SPST, Finder Type 34.81 (opto relays/coupler), vertical/standing form, see https://gfinder.findernet.com/public/attachments/34/EN/S34USAEN.pdf +Relay SPST Finder +0 +4 +4 +OptoDevice +Hamamatsu_C12880 +Hamamatsu spectrometer, see http://www.hamamatsu.com/resources/pdf/ssd/c12880ma_kacc1226e.pdf +opto spectrometer Hamamatsu +0 +10 +10 +OptoDevice +Hamamatsu_S13360-30CS +SiPM, 2pin +Hamamatsu SiPM +0 +2 +2 +OptoDevice +Kingbright_KPS-5130 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KPS-5130PD7C(Ver.14).pdf +KPS-5130 photodiode RGB sensor +0 +4 +4 +OptoDevice +Kingbright_KRC011_Horizontal +Subminiature Reflective Optical Sensor, http://www.kingbright.com/attachments/file/psearch/000/00/00/KRC011(Ver.15).pdf +Subminiature Reflective Optical Sensor +0 +4 +4 +OptoDevice +Kingbright_KRC011_Vertical +Subminiature Reflective Optical Sensor, http://www.kingbright.com/attachments/file/psearch/000/00/00/KRC011(Ver.15).pdf +Subminiature Reflective Optical Sensor +0 +4 +4 +OptoDevice +Kodenshi_LG206D +http://kodenshi.co.jp/products/pdf/sensor/photointerrupter_ic/LG206D.pdf +Photointerrupter infrared LED with photo IC +0 +5 +5 +OptoDevice +Kodenshi_LG206L +http://kodenshi.co.jp/products/pdf/sensor/photointerrupter_ic/LG205L.pdf +Photointerrupter infrared LED with photo IC +0 +5 +5 +OptoDevice +Kodenshi_SG105 +package for Kodenshi SG-105 with PCB cutout, light-direction upwards, see http://www.kodenshi.co.jp/products/pdf/sensor/photointerrupter_ref/SG-105.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Kodenshi_SG105F +package for Kodenshi SG-105F, see http://www.kodenshi.co.jp/products/pdf/sensor/photointerrupter_ref/SG-105F.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Kodenshi_SG105_Reverse +package for Kodenshi SG-105 with PCB cutout, light-direction downwards, see http://www.kodenshi.co.jp/products/pdf/sensor/photointerrupter_ref/SG-105.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +LaserDiode_TO3.3-D3.3-3 +Laser Diode, TO-3.3mm, 3pin +Laser Diode TO3.3 +0 +3 +3 +OptoDevice +LaserDiode_TO5-D9-3 +Laser Diode, TO5-like (D=9mm), 3pin +Laser Diode TO5-like +0 +3 +3 +OptoDevice +LaserDiode_TO18-D5.6-3 +Laser Diode, TO18-like (D=5.6mm), 3pin +Laser Diode TO18-like +0 +3 +3 +OptoDevice +LaserDiode_TO38ICut-3 +Laser Diode, TO-38-ICut, 3pin +Laser Diode TO38-ICut +0 +3 +3 +OptoDevice +LaserDiode_TO56-3 +Laser Diode, TO-56, 3pin +Laser Diode TO56 +0 +3 +3 +OptoDevice +Lightpipe_LPF-C012303S +https://www.lumex.com/spec/LPF-C012303S.pdf +lightpipe dual tower right angle 3mm +0 +0 +0 +OptoDevice +Lightpipe_Mentor_1275.x00x +https://www.mentor-bauelemente.de/katalog/ll/MENTOR-LL.pdf +spherical light pipe 4 way 3mm PLCC-2 PLCC-4 +0 +0 +0 +OptoDevice +Lightpipe_Mentor_1276.1004 +https://www.mentor-bauelemente.de/katalog/ll/MENTOR-LL.pdf +spherical light pipe 4 way 3mm PLCC-2 PLCC-4 +0 +0 +0 +OptoDevice +Lightpipe_Mentor_1276.2004 +https://www.mentor-bauelemente.de/katalog/ll/MENTOR-LL.pdf +planar light pipe 4 way 3mm PLCC-2 PLCC-4 +0 +0 +0 +OptoDevice +Lite-On_LTR-303ALS-01 +ambient light sensor, i2c interface, 6-pin chipled package, http://optoelectronics.liteon.com/upload/download/DS86-2013-0004/LTR-303ALS-01_DS_V1.pdf +ambient light sensor chipled +0 +6 +6 +OptoDevice +Luna_NSL-32 +Optoisolator with LED and photoresistor +optoisolator +0 +4 +4 +OptoDevice +Maxim_OLGA-14_3.3x5.6mm_P0.8mm +https://pdfserv.maximintegrated.com/land_patterns/90-0602.PDF +OLGA-14 OESIP-14 +0 +14 +14 +OptoDevice +ONSemi_QSE15x +3 Lead Plastic Package +ONSemi QSE158 QSE159 +0 +3 +3 +OptoDevice +OnSemi_CASE100AQ +OnSemi CASE 100AQ for QRE1113, see https://www.onsemi.com/pub/Collateral/QRE1113-D.PDF +reflective opto couple photo coupler +0 +4 +4 +OptoDevice +OnSemi_CASE100CY +OnSemi CASE 100CY, light-direction upwards, see http://www.onsemi.com/pub/Collateral/QRE1113-D.PDF +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Osram_BPW82 +PhotoDiode, BPW82, RM2.54 +PhotoDiode BPW82 RM2.54 +0 +2 +2 +OptoDevice +Osram_DIL2_4.3x4.65mm_P5.08mm +PhotoDiode, plastic DIL, 4.3x4.65mm², RM5.08 +PhotoDiode plastic DIL RM5.08 +0 +2 +2 +OptoDevice +Osram_LPT80A +PhotoTransistor, sidelooker package, RM2.54 +PhotoTransistor sidelooker package RM2.54 +0 +2 +2 +OptoDevice +Osram_SFH9x0x +package for Osram SFH9x0x series of reflective photo interrupters/couplers, see http://www.osram-os.com/Graphics/XPic6/00200860_0.pdf +reflective photo interrupter SMD +0 +6 +6 +OptoDevice +Osram_SFH205 +PhotoDiode, SFH205, RM2.54 +PhotoDiode SFH205 RM2.54 +0 +2 +2 +OptoDevice +Osram_SFH225 +PhotoDiode, SFH225, RM2.54 +PhotoDiode SFH225 RM2.54 +0 +2 +2 +OptoDevice +Osram_SMD-DIL2_4.5x4.0mm +PhotoDiode, plastic SMD DIL, 4.5x4mm² +PhotoDiode plastic SMD DIL +0 +2 +2 +OptoDevice +Osram_SMD-SmartDIL +PhotoDiode, plastic SMD SmatDIL +PhotoDiode plastic SMD SmatDIL +0 +3 +3 +OptoDevice +Panasonic_APV-AQY_SSOP-4_4.45x2.65mm_P1.27mm +https://www.panasonic-electric-works.com/cps/rde/xbcr/pew_eu_en/technical_information_photomos_en.pdf +SSOP4 APV21 AQY22 +0 +4 +4 +OptoDevice +PerkinElmer_VTL5C +Axial Vactrol (http://www.qsl.net/wa1ion/vactrol/vactrol.pdf) +vactrol +0 +4 +4 +OptoDevice +PerkinElmer_VTL5Cx2 +Axial Vactrol (http://www.qsl.net/wa1ion/vactrol/vactrol.pdf) +vactrol +0 +5 +5 +OptoDevice +R_LDR_4.9x4.2mm_P2.54mm_Vertical +Resistor, LDR 4.9x4.2mm +Resistor LDR4.9x4.2 +0 +2 +2 +OptoDevice +R_LDR_5.0x4.1mm_P3mm_Vertical +Resistor, LDR 5x4.1mm, see http://cdn-reichelt.de/documents/datenblatt/A500/A90xxxx%23PE.pdf +Resistor LDR5x4.1mm +0 +2 +2 +OptoDevice +R_LDR_5.1x4.3mm_P3.4mm_Vertical +Resistor, LDR 5.1x3.4mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR5.1x3.4mm +0 +2 +2 +OptoDevice +R_LDR_5.2x5.2mm_P3.5mm_Horizontal +Resistor, LDR 5.2x5.2, upright, see http://cdn-reichelt.de/documents/datenblatt/A500/M996011A.pdf +Resistor LDR5.2x5.2 +0 +2 +2 +OptoDevice +R_LDR_7x6mm_P5.1mm_Vertical +Resistor, LDR 7x6mm +Resistor LDR7x6mm +0 +2 +2 +OptoDevice +R_LDR_10x8.5mm_P7.6mm_Vertical +Resistor, LDR 10x8.5mm +Resistor LDR10.8.5mm +0 +2 +2 +OptoDevice +R_LDR_11x9.4mm_P8.2mm_Vertical +Resistor, LDR 11x9.4mm +Resistor LDR11x9.4mm +0 +2 +2 +OptoDevice +R_LDR_12x10.8mm_P9.0mm_Vertical +Resistor, LDR 12x10.8mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR12x10.8mm +0 +2 +2 +OptoDevice +R_LDR_D6.4mm_P3.4mm_Vertical +Resistor, LDR D=6.4mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDRD=6.4mm +0 +2 +2 +OptoDevice +R_LDR_D13.8mm_P9.0mm_Vertical +Resistor, diameter 13.8mm pitch 9mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR +0 +2 +2 +OptoDevice +R_LDR_D20mm_P17.5mm_Vertical +Resistor, LDR 20mm diameter, pin pitch 17.5mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR +0 +2 +2 +OptoDevice +ST_VL53L0X +https://www.st.com/resource/en/datasheet/vl53l1x.pdf +laser-ranging sensor +0 +12 +12 +OptoDevice +ST_VL53L1X +https://www.st.com/resource/en/datasheet/vl53l1x.pdf +laser-ranging sensor +0 +12 +12 +OptoDevice +Sharp_GP2Y0A41SK0F +http://www.sharp-world.com/products/device/lineup/data/pdf/datasheet/gp2y0a41sk_e.pdf +Distance Sensor Sharp +0 +2 +2 +OptoDevice +Sharp_IS471F +Sharp OPIC IS471F, see http://pdf.datasheetcatalog.com/datasheet/Sharp/mXvrzty.pdf +Sharp OPIC IS471F +0 +4 +4 +OptoDevice +Sharp_IS485 +Sharp OPIC, IS485, IS486, see http://microrato.ua.pt/main/Actividades/Estagios/Docs/IS485_6.pdf +Sharp OPIC IS485 IS486 +0 +3 +3 +OptoDevice +Siemens_SFH900 +package for Siemens SFH900 reflex photo interrupter/coupler/object detector, see https://www.batronix.com/pdf/sfh900.pdf +Siemens SFH900 reflex photo interrupter coupler object detector +0 +3 +3 +OptoDevice +Toshiba_TORX170_TORX173_TORX193_TORX194 +Fiberoptic Reciver, RX, Toshiba, Toslink, TORX170, TORX173, TORX193, TORX194 +Fiberoptic Reciver RX Toshiba Toslink TORX170 TORX173 TORX193 TORX194 +0 +6 +6 +OptoDevice +Toshiba_TOTX170_TOTX173_TOTX193_TOTX194 +Fiberoptic Reciver, RX, Toshiba, Toslink, TORX170, TORX173, TORX193, TORX194 +Fiberoptic Reciver RX Toshiba Toslink TORX170 TORX173 TORX193 TORX194 +0 +6 +6 +OptoDevice +Vishay_CAST-3Pin +IR Receiver Vishay TSOP-xxxx, CAST package, see https://www.vishay.com/docs/82493/tsop311.pdf +IRReceiverVishayTSOP-xxxx CAST +0 +3 +3 +OptoDevice +Vishay_CNY70 +package for Vishay CNY70 refective photo coupler/interrupter +Vishay CNY70 refective photo coupler +0 +4 +4 +OptoDevice +Vishay_MINICAST-3Pin +IR Receiver Vishay TSOP-xxxx, MINICAST package, see https://www.vishay.com/docs/82669/tsop32s40f.pdf +IR Receiver Vishay TSOP-xxxx MINICAST +0 +3 +3 +OptoDevice +Vishay_MINIMOLD-3Pin +IR Receiver Vishay TSOP-xxxx, MINIMOLD package, see https://www.vishay.com/docs/82742/tsop331.pdf +IR Receiver Vishay TSOP-xxxx MINIMOLD +0 +3 +3 +OptoDevice +Vishay_MOLD-3Pin +IR Receiver Vishay TSOP-xxxx, MOLD package, see https://www.vishay.com/docs/82669/tsop32s40f.pdf +IR Receiver Vishay TSOP-xxxx MOLD +0 +3 +3 +Oscillator +Oscillator_DIP-8 +Oscillator, DIP8,http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_DIP-8_LargePads +Oscillator, DIP8, Large Pads, http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_DIP-14 +Oscillator, DIP14, http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_DIP-14_LargePads +Oscillator, DIP14, Large Pads, http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_OCXO_Morion_MV267 +http://www.morion.com.ru/catalog_pdf/MV267.pdf +OCXO +0 +5 +5 +Oscillator +Oscillator_OCXO_Morion_MV317 +https://www.morion-us.com/catalog_pdf/mv317.pdf +OCXO +0 +5 +5 +Oscillator +Oscillator_SMD_Abracon_ABLNO +https://abracon.com/Precisiontiming/ABLNO.pdf +VCXO XO +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASCO-4Pin_1.6x1.2mm +Miniature Crystal Clock Oscillator Abracon ASCO series, https://abracon.com/Oscillators/ASCO.pdf, 1.6x1.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASDMB-4Pin_2.5x2.0mm +Miniature Crystal Clock Oscillator Abracon ASDMB series, 2.5x2.0mm package, http://www.abracon.com/Oscillators/ASDMB.pdf +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASE-4Pin_3.2x2.5mm +Miniature Crystal Clock Oscillator Abracon ASE series, http://www.abracon.com/Oscillators/ASEseries.pdf, 3.2x2.5mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASE-4Pin_3.2x2.5mm_HandSoldering +Miniature Crystal Clock Oscillator Abracon ASE series, http://www.abracon.com/Oscillators/ASEseries.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASV-4Pin_7.0x5.1mm +Miniature Crystal Clock Oscillator Abracon ASV series, http://www.abracon.com/Oscillators/ASV.pdf, 7.0x5.1mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASV-4Pin_7.0x5.1mm_HandSoldering +Miniature Crystal Clock Oscillator Abracon ASV series, http://www.abracon.com/Oscillators/ASV.pdf, hand-soldering, 7.0x5.1mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Diodes_FN-4Pin_7.0x5.0mm +FN Series Crystal Clock Oscillator (XO) (https://www.diodes.com/assets/Datasheets/FN_3-3V.pdf) +Oscillator Crystal SMD SMT +0 +4 +4 +Oscillator +Oscillator_SMD_ECS_2520MV-xxx-xx-4Pin_2.5x2.0mm +Miniature Crystal Clock Oscillator ECS 2520MV series, https://www.ecsxtal.com/store/pdf/ECS-2520MV.pdf +Miniature Crystal Clock Oscillator ECS 2520MV series SMD SMT HCMOS +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO32-4Pin_3.2x2.5mm +Miniature Crystal Clock Oscillator EuroQuartz XO32 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO32.pdf, 3.2x2.5mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO32-4Pin_3.2x2.5mm_HandSoldering +Miniature Crystal Clock Oscillator EuroQuartz XO32 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO32.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO53-4Pin_5.0x3.2mm +Miniature Crystal Clock Oscillator EuroQuartz XO53 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO53.pdf, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO53-4Pin_5.0x3.2mm_HandSoldering +Miniature Crystal Clock Oscillator EuroQuartz XO53 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO53.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO91-4Pin_7.0x5.0mm +Miniature Crystal Clock Oscillator EuroQuartz XO91 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO91.pdf, 7.0x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO91-4Pin_7.0x5.0mm_HandSoldering +Miniature Crystal Clock Oscillator EuroQuartz XO91 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO91.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS1-6Pin_14.8x9.1mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S1-KHZ/LHZ, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 14.8x9.1mm^2 package +SMD SMT crystal oscillator +0 +6 +6 +Oscillator +Oscillator_SMD_Fordahl_DFAS2-4Pin_7.3x5.1mm +Mminiature Crystal Clock Oscillator TXCO Fordahl DFA S2-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 7.3x5.1mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS2-4Pin_7.3x5.1mm_HandSoldering +Mminiature Crystal Clock Oscillator TXCO Fordahl DFA S2-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 7.3x5.1mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS3-4Pin_9.1x7.2mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S3-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 9.1x7.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS3-4Pin_9.1x7.2mm_HandSoldering +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S3-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 9.1x7.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS7-4Pin_19.9x12.9mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S7-K/L, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 19.9x12.9mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS7-4Pin_19.9x12.9mm_HandSoldering +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S7-K/L, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 19.9x12.9mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS11-4Pin_7.0x5.0mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S11-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 7.0x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS11-4Pin_7.0x5.0mm_HandSoldering +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S11-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS15-4Pin_5.0x3.2mm +Ultraminiature Crystal Clock Oscillator TXCO Fordahl DFA S15-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS15-4Pin_5.0x3.2mm_HandSoldering +Ultraminiature Crystal Clock Oscillator TXCO Fordahl DFA S15-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_IDT_JS6-6_5.0x3.2mm_P1.27mm +SMD Crystal Oscillator IDT https://www.idt.com/document/dst/xu-family-datasheet#page=15, 5.0x3.2mm +SMD SMT crystal oscillator +0 +6 +6 +Oscillator +Oscillator_SMD_IDT_JU6-6_7.0x5.0mm_P2.54mm +SMD Crystal Oscillator IDT https://www.idt.com/document/dst/xu-family-datasheet#page=17, 7.0x5.0mm +SMD SMT crystal oscillator +0 +6 +6 +Oscillator +Oscillator_SMD_IQD_IQXO70-4Pin_7.5x5.0mm +IQD Crystal Clock Oscillator IQXO-70, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 7.5x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_IQD_IQXO70-4Pin_7.5x5.0mm_HandSoldering +IQD Crystal Clock Oscillator IQXO-70, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 7.5x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Kyocera_2520-6Pin_2.5x2.0mm +https://global.kyocera.com/prdct/electro/product/pdf/kt2520_e.pdf +2.5mm 2mm SMD +0 +6 +6 +Oscillator +Oscillator_SMD_Kyocera_KC2520Z-4Pin_2.5x2.0mm +https://global.kyocera.com/prdct/electro/product/pdf/clock_z_xz_e.pdf +2.5mm 2mm SMD +0 +4 +4 +Oscillator +Oscillator_SMD_OCXO_ConnorWinfield_OH300 +http://www.conwin.com/datasheets/cx/cx282.pdf +OCXO +0 +7 +7 +Oscillator +Oscillator_SMD_SI570_SI571_HandSoldering +SI570, SI571, Programmable oscillator, Standard +SI570 SI571 Programmable oscillator Standard +0 +8 +8 +Oscillator +Oscillator_SMD_SI570_SI571_Standard +SI570, SI571, Programmable oscillator, Standard +SI570 SI571 Programmable oscillator Standard +0 +8 +8 +Oscillator +Oscillator_SMD_SeikoEpson_SG210-4Pin_2.5x2.0mm +SMD Crystal Oscillator Seiko Epson SG-210 https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-210SED, 2.5x2.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG210-4Pin_2.5x2.0mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-210 https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-210SED, hand-soldering, 2.5x2.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG3030CM +SMD Crystal Oscillator Seiko Epson SG-3030CM package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CA-4Pin_7.0x5.0mm +SMD Crystal Oscillator Seiko Epson SG-8002CA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 7.0x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CA-4Pin_7.0x5.0mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002CA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CE-4Pin_3.2x2.5mm +SMD Crystal Oscillator Seiko Epson SG-8002CE https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 3.2x2.5mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CE-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002CE https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JA-4Pin_14.0x8.7mm +SMD Crystal Oscillator Seiko Epson SG-8002JA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 14.0x8.7mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JA-4Pin_14.0x8.7mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002JA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 14.0x8.7mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JC-4Pin_10.5x5.0mm +SMD Crystal Oscillator Seiko Epson SG-8002JC https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 10.5x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JC-4Pin_10.5x5.0mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002JC https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 10.5x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002LB-4Pin_5.0x3.2mm +SMD Crystal Oscillator Seiko Epson SG-8002LB https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002LB-4Pin_5.0x3.2mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002LB https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Silicon_Labs_LGA-6_2.5x3.2mm_P1.25mm +Silicon_Labs LGA, 6 Pin (https://www.silabs.com/documents/public/data-sheets/si512-13.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Silicon_Labs LGA NoLead +0 +6 +6 +Oscillator +Oscillator_SMD_TCXO_G158 +TCXO +TCXO +0 +4 +4 +Oscillator +Oscillator_SMD_TXC_7C-4Pin_5.0x3.2mm +Miniature Crystal Clock Oscillator TXC 7C series, http://www.txccorp.com/download/products/osc/7C_o.pdf, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_TXC_7C-4Pin_5.0x3.2mm_HandSoldering +Miniature Crystal Clock Oscillator TXC 7C series, http://www.txccorp.com/download/products/osc/7C_o.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SeikoEpson_SG-8002DB +14-lead dip package, row spacing 7.62 mm (300 mils) +DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Oscillator +Oscillator_SeikoEpson_SG-8002DC +8-lead dip package, row spacing 7.62 mm (300 mils) +DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Package_BGA +Analog_BGA-28_4.0x6.25mm_Layout4x7_P0.8mm_Ball0.45mm_Pad0.4 +Analog BGA-28 4.0mm x 6.25mm package, pitch 0.4mm pad, based on https://www.analog.com/media/en/technical-documentation/data-sheets/8063fa.pdf +BGA 28 0.8 +0 +28 +28 +Package_BGA +BGA-9_1.6x1.6mm_Layout3x3_P0.5mm +BGA-9, http://www.ti.com/lit/ds/symlink/bq27421-g1.pdf +BGA-9 +0 +9 +9 +Package_BGA +BGA-16_1.92x1.92mm_Layout4x4_P0.5mm +BGA-16, http://www.st.com/content/ccc/resource/technical/document/datasheet/group2/bc/cd/62/9e/8f/30/47/69/CD00151267/files/CD00151267.pdf/jcr:content/translations/en.CD00151267.pdf +BGA-16 +0 +16 +16 +Package_BGA +BGA-25_6.35x6.35mm_Layout5x5_P1.27mm +BGA-25, http://cds.linear.com/docs/en/datasheet/4624fc.pdf +BGA-25 uModule +0 +25 +25 +Package_BGA +BGA-36_3.396x3.466mm_Layout6x6_P0.4mm_Ball0.25mm_Pad0.2mm_NSMD +Altera V36, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00486-00.pdf +Altera BGA-36 V36 VBGA +0 +36 +36 +Package_BGA +BGA-48_8.0x9.0mm_Layout6x8_P0.8mm +BGA-48 - pitch 0.8 mm +BGA-48 +0 +48 +48 +Package_BGA +BGA-64_9.0x9.0mm_Layout10x10_P0.8mm +BGA-64, 10x10 raster, 9x9mm package, pitch 0.8mm +BGA-64 +0 +64 +64 +Package_BGA +BGA-68_5.0x5.0mm_Layout9x9_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-68, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00344-01.pdf +Altera BGA-68 M68 MBGA +0 +68 +68 +Package_BGA +BGA-81_4.496x4.377mm_Layout9x9_P0.4mm_Ball0.25mm_Pad0.2mm_NSMD +Altera V81, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00478-01.pdf +Altera VBGA V81 BGA-81 +0 +81 +81 +Package_BGA +BGA-90_8.0x13.0mm_Layout2x3x15_P0.8mm +BGA-90, http://www.issi.com/WW/pdf/42-45S32800J.pdf +BGA-90 +0 +90 +90 +Package_BGA +BGA-96_9.0x13.0mm_Layout2x3x16_P0.8mm +BGA-96, http://www.mouser.com/ds/2/198/43-46TR16640B-81280BL-706483.pdf +BGA-96 +0 +96 +96 +Package_BGA +BGA-100_6.0x6.0mm_Layout11x11_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-100, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00345-01.pdf +Altera BGA-100 M100 MBGA +0 +100 +100 +Package_BGA +BGA-100_11.0x11.0mm_Layout10x10_P1.0mm_Ball0.5mm_Pad0.4mm_NSMD +BGA-100, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00223-02.pdf +BGA-100 +0 +100 +100 +Package_BGA +BGA-121_9.0x9.0mm_Layout11x11_P0.8mm_Ball0.4mm_Pad0.35mm_NSMD +121-ball, 0.8mm BGA (based on http://www.latticesemi.com/view_document?document_id=213) +BGA 0.8mm 9mm 121 +0 +121 +121 +Package_BGA +BGA-121_12.0x12.0mm_Layout11x11_P1.0mm +BGA-121, http://cds.linear.com/docs/en/packaging/05081891_A_bga121.pdf +BGA-121 +0 +121 +121 +Package_BGA +BGA-132_12x18mm_Layout11x17_P0.5mm +BGA-132 11x17 12x18mm 0.5pitch +BGA-132 +0 +132 +132 +Package_BGA +BGA-144_7.0x7.0mm_Layout13x13_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-144, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00346-00.pdf +Altera BGA-144 M144 MBGA +0 +144 +144 +Package_BGA +BGA-144_13.0x13.0mm_Layout12x12_P1.0mm +BGA-144, http://www.topline.tv/drawings/pdf/BGA%201,0mm%20pitch/LBGA144T1.0-DC128.pdf +BGA-144 +0 +144 +144 +Package_BGA +BGA-152_14x18mm_Layout13x17_P0.5mm +BGA-152_14x18mm_Layout13x17_P0.5mm +VBGA-152 +0 +152 +152 +Package_BGA +BGA-153_8.0x8.0mm_Layout15x15_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-153, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00471-00.pdf +Altera BGA-153 M153 MBGA +0 +153 +153 +Package_BGA +BGA-169_11.0x11.0mm_Layout13x13_P0.8mm_Ball0.5mm_Pad0.4mm_NSMD +Altera U169, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00470-01.pdf +Altera UBGA U169 BGA-169 +0 +169 +169 +Package_BGA +BGA-256_11.0x11.0mm_Layout20x20_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-256, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00348-01.pdf +Altera BGA-256 M256 MBGA +0 +256 +256 +Package_BGA +BGA-256_14.0x14.0mm_Layout16x16_P0.8mm_Ball0.45mm_Pad0.32mm_NSMD +BGA-256, dimensions: https://www.xilinx.com/support/documentation/package_specs/ft256.pdf, design rules: https://www.xilinx.com/support/documentation/user_guides/ug1099-bga-device-design-rules.pdf +BGA-256 +0 +256 +256 +Package_BGA +BGA-256_17.0x17.0mm_Layout16x16_P1.0mm_Ball0.5mm_Pad0.4mm_NSMD +BGA-256, dimensions: https://www.xilinx.com/support/documentation/package_specs/ft256.pdf, design rules: https://www.xilinx.com/support/documentation/user_guides/ug1099-bga-device-design-rules.pdf +BGA-256 +0 +256 +256 +Package_BGA +BGA-324_15.0x15.0mm_Layout18x18_P0.8mm_Ball0.5mm_Pad0.4mm_NSMD +Altera U324, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00474-02.pdf +Altera UBGA U324 BGA-324 +0 +324 +324 +Package_BGA +BGA-324_19.0x19.0mm_Layout18x18_P1.0mm_Ball0.5mm_Pad0.4mm_NSMD +BGA-324, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00233-03.pdf +BGA-324 +0 +324 +324 +Package_BGA +BGA-352_35.0x35.0mm_Layout26x26_P1.27mm +BGA-352, https://www.fujitsu.com/downloads/MICRO/fma/pdfmcu/b352p05.pdf +BGA-352 +0 +352 +352 +Package_BGA +BGA-400_21.0x21.0mm_Layout20x20_P1.0mm +BGA-400, https://www.xilinx.com/support/documentation/package_specs/fg400.pdf +BGA-400 +0 +400 +400 +Package_BGA +BGA-484_23.0x23.0mm_Layout22x22_P1.0mm +BGA-484, https://www.xilinx.com/support/documentation/package_specs/fg484.pdf +BGA-484 +0 +484 +484 +Package_BGA +BGA-624_21.0x21.0mm_Layout25x25_P0.8mm +BGA-624, 25x25 grid, 21x21mm package, pitch 0.8mm; https://www.nxp.com/docs/en/package-information/SOT1529-1.pdf +BGA 624 0.8 +0 +624 +624 +Package_BGA +BGA-625_21.0x21.0mm_Layout25x25_P0.8mm +BGA-625 +BGA-625 +0 +625 +625 +Package_BGA +BGA-672_27.0x27.0mm_Layout26x26_P1.0mm_Ball0.6mm_Pad0.5mm_NSMD +Altera BGA-672, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00472-00.pdf +Altera BGA-672 F672 FBGA +0 +672 +672 +Package_BGA +BGA-676_27.0x27.0mm_Layout26x26_P1.0mm_Ball0.6mm_Pad0.5mm_NSMD +XILINX BGA-676, https://www.xilinx.com/support/documentation/package_specs/fg676.pdf +XILINX BGA-676 FG676/FGG676 +0 +676 +676 +Package_BGA +BGA-1023_33.0x33.0mm_Layout32x32_P1.0mm +BGA-1023 +BGA-1023 +0 +1023 +1023 +Package_BGA +BGA-1156_35.0x35.0mm_Layout34x34_P1.0mm +BGA-1156 +BGA-1156 +0 +1156 +1156 +Package_BGA +BGA-1295_37.5x37.5mm_Layout36x36_P1.0mm +BGA-1295 +BGA-1295 +0 +1295 +1295 +Package_BGA +FB-BGA-484_23.0x23.0mm_Layout22x22_P1.0mm +Xilinx FB-484, https://www.xilinx.com/support/documentation/user_guides/ug1099-bga-device-design-rules.pdf +FB-BGA-484 +0 +484 +484 +Package_BGA +FBGA-78_7.5x11mm_Layout2x3x13_P0.8mm +FBGA-78, https://www.skhynix.com/product/filedata/fileDownload.do?seq=7687 +FBGA-78 +0 +78 +78 +Package_BGA +Fujitsu_WLP-15_2.28x3.092mm_Layout3x5_P0.4mm +WLP-15, 3x5 raster, 2.28x3.092mm package, pitch 0.4mm; http://www.fujitsu.com/global/documents/products/devices/semiconductor/fram/lineup/MB85RS1MT-DS501-00022-7v0-E.pdf +BGA 8 0.4 +0 +8 +8 +Package_BGA +LFBGA-100_10x10mm_Layout10x10_P0.8mm +LFBGA-100, 10x10 raster, 10x10mm package, pitch 0.8mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f103tb.pdf +BGA 100 0.8 +0 +100 +100 +Package_BGA +LFBGA-144_10x10mm_Layout12x12_P0.8mm +LFBGA-144, 12x12 raster, 10x10mm package, pitch 0.8mm; see section 6.1 of http://www.st.com/resource/en/datasheet/stm32f103ze.pdf +BGA 144 0.8 +0 +144 +144 +Package_BGA +LFBGA-169_16x12mm_Layout28x14_P0.5mm_Ball0.3_Pad0.3mm_NSMD +https://4donline.ihs.com/images/VipMasterIC/IC/SGST/SGSTS20279/SGSTS20279-1.pdf?hkey=EF798316E3902B6ED9A73243A3159BB0 +eMMC Flash LFBGA169 +0 +169 +169 +Package_BGA +Lattice_caBGA-381_17.0x17.0mm_Layout20x20_P0.8mm_Ball0.4mm_Pad0.4mm_NSMD +Lattice caBGA-381 footprint for ECP5 FPGAs, based on http://www.latticesemi.com/view_document?document_id=213 +BGA 381 0.8 +0 +381 +381 +Package_BGA +Lattice_caBGA-381_17.0x17.0mm_Layout20x20_P0.8mm_Ball0.4mm_Pad0.6mm_SMD +Lattice caBGA-381 footprint for ECP5 FPGAs, based on http://www.latticesemi.com/view_document?document_id=213 +BGA 381 0.8 +0 +381 +381 +Package_BGA +Linear_BGA-133_15.0x15.0mm_Layout12x12_P1.27mm +Analog Devices (Linear Tech), 133-pin BGA uModule, 15.0x15.0x4.92mm, https://www.analog.com/media/en/technical-documentation/data-sheets/4637fc.pdf +133 pin bga +0 +134 +134 +Package_BGA +Maxim_WLP-9_1.595x1.415_Layout3x3_P0.4mm_Ball0.27mm_Pad0.25mm_NSMD +Maxim_WLP-9 W91C1+1 https://pdfserv.maximintegrated.com/package_dwgs/21-0459.PDF +Maxim_WLP-9 +0 +9 +9 +Package_BGA +Maxim_WLP-12 +Maxim_WLP-12 W121B2+1 http://pdfserv.maximintegrated.com/package_dwgs/21-0009.PDF +Maxim_WLP-12 +0 +12 +12 +Package_BGA +Microchip_TFBGA-196_11x11mm_Layout14x14_P0.75mm_SMD +TFBGA-196, 11.0x11.0mm, 196 Ball, 14x14 Layout, 0.75mm Pitch, http://ww1.microchip.com/downloads/en/DeviceDoc/SAMA5D2-Series-Data-Sheet-DS60001476C.pdf#page=2956 +BGA 196 0.75 +0 +196 +196 +Package_BGA +ST_uTFBGA-36_3.6x3.6mm_Layout6x6_P0.5mm +ST uTFBGA-36, 0.25mm pad, 3.6x3.6mm, 36 Ball, 6x6 Layout, 0.5mm Pitch, https://www.st.com/resource/en/datasheet/stulpi01a.pdf +BGA 36 0.5 +0 +36 +36 +Package_BGA +TFBGA-64_5x5mm_Layout8x8_P0.5mm +TFBGA-64, 8x8 raster, 5x5mm package, pitch 0.5mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f100v8.pdf +BGA 64 0.5 +0 +64 +64 +Package_BGA +TFBGA-100_8x8mm_Layout10x10_P0.8mm +TFBGA-100, 10x10 raster, 8x8mm package, pitch 0.8mm; see section 6.2 of http://www.st.com/resource/en/datasheet/stm32f746zg.pdf +BGA 100 0.8 +0 +100 +100 +Package_BGA +TFBGA-100_9.0x9.0mm_Layout10x10_P0.8mm +TFBGA-100, 10x10, 9x9mm package, pitch 0.8mm +TFBGA-100 +0 +100 +100 +Package_BGA +TFBGA-121_10x10mm_Layout11x11_P0.8mm +TFBGA-121, 11x11 raster, 10x10mm package, pitch 0.8mm; http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#p495 +BGA 121 0.8 +0 +121 +121 +Package_BGA +TFBGA-216_13x13mm_Layout15x15_P0.8mm +TFBGA-216, 15x15 raster, 13x13mm package, pitch 0.8mm; see section 6.8 of http://www.st.com/resource/en/datasheet/stm32f746zg.pdf +BGA 216 0.8 +0 +216 +216 +Package_BGA +TFBGA-265_14x14mm_Layout17x17_P0.8mm +TFBGA-265, 17x17 raster, 14x14mm package, pitch 0.8mm; see section 7.8 of http://www.st.com/resource/en/datasheet/DM00387108.pdf +BGA 265 0.8 +0 +265 +265 +Package_BGA +Texas_DSBGA-5_0.822x1.116mm_Layout2x1x2_P0.4mm +Texas Instruments, DSBGA, 0.822x1.116mm, 5 bump 2x1x2 array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/opa330.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YFF S-XBGA-N5 +0 +10 +5 +Package_BGA +Texas_DSBGA-6_0.9x1.4mm_Layout2x3_P0.5mm +Texas Instruments, DSBGA, 0.9x1.4mm, 6 bump 2x3 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/ts5a3159a.pdf) +Texas Instruments DSBGA BGA YZP R-XBGA-N6 +0 +12 +6 +Package_BGA +Texas_DSBGA-8_0.9x1.9mm_Layout2x4_P0.5mm +Texas Instruments, DSBGA, 0.9x1.9mm, 8 bump 2x4 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txb0102.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YZP R-XBGA-N8 +0 +16 +8 +Package_BGA +Texas_DSBGA-8_1.43x1.41mm_Layout3x3_P0.5mm +Texas Instruments, DSBGA, 1.43x1.41mm, 8 bump 3x3 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/lmc555.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YZP R-XBGA-N8 +0 +16 +8 +Package_BGA +Texas_DSBGA-8_1.5195x1.5195mm_Layout3x3_P0.5mm +Texas Instruments, DSBGA, 1.5195x1.5195x0.600mm, 8 ball 3x3 area grid, YZR pad definition (http://www.ti.com/lit/ml/mxbg270/mxbg270.pdf) +BGA 8 0.5 +0 +8 +8 +Package_BGA +Texas_DSBGA-9_1.4715x1.4715mm_Layout3x3_P0.5mm +Texas Instruments, DSBGA, 1.4715x1.4715mm, 9 bump 3x3 array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/lm4990.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YZR0009 +0 +18 +9 +Package_BGA +Texas_DSBGA-10_1.36x1.86mm_Layout3x4_P0.5mm +Texas Instruments, DSBGA, 1.36x1.86mm, 10 bump 3x4 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txs0104e.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA +0 +20 +10 +Package_BGA +Texas_DSBGA-12_1.36x1.86mm_Layout3x4_P0.5mm +Texas Instruments, DSBGA, 1.36x1.86mm, 12 bump 3x4 (area) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txs0104e.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA +0 +24 +12 +Package_BGA +Texas_DSBGA-28_1.9x3.0mm_Layout4x7_P0.4mm +Texas Instruments, DSBGA, 3.0x1.9x0.625mm, 28 ball 7x4 area grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/bq51050b.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +BGA 28 0.4 +0 +28 +28 +Package_BGA +Texas_DSBGA-49_3.33x3.488mm_Layout7x7_P0.4mm +Texas Instruments, DSBGA, 3.33x3.488x0.625mm, 49 ball 7x7 area grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/msp430f2234.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +texas dsbga 49 +0 +49 +49 +Package_BGA +Texas_DSBGA-64_3.415x3.535mm_Layout8x8_P0.4mm +Texas Instruments, DSBGA, 3.415x3.535x0.625mm, 64 ball 8x8 area grid, NSMD pad definition (http://www.ti.com/lit/ds/slas718g/slas718g.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +texas dsbga 64 +0 +64 +64 +Package_BGA +Texas_MicroStar_Junior_BGA-12_2.0x2.5mm_Layout4x3_P0.5mm +Texas Instruments, BGA Microstar Junior, 2x2.5mm, 12 bump 4x3 grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txb0104.pdf, http://www.ti.com/lit/wp/ssyz015b/ssyz015b.pdf) +Texas_Junior_BGA-12 +0 +12 +12 +Package_BGA +Texas_MicroStar_Junior_BGA-80_5.0x5.0mm_Layout9x9_P0.5mm +Texas Instruments, BGA Microstar Junior, 5x5mm, 80 ball 9x9 grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/tlv320aic23b.pdf, http://www.ti.com/lit/wp/ssyz015b/ssyz015b.pdf) +Texas_Junior_BGA-80 +0 +80 +80 +Package_BGA +Texas_MicroStar_Junior_BGA-113_7.0x7.0mm_Layout12x12_P0.5mm +Texas Instruments, BGA Microstar Junior, 7x7mm, 113 ball 12x12 grid, NSMD pad definition (http://www.ti.com/lit/ml/mpbg674/mpbg674.pdf, http://www.ti.com/lit/wp/ssyz015b/ssyz015b.pdf) +Texas_Junior_BGA-113 +0 +113 +113 +Package_BGA +UCBGA-36_2.5x2.5mm_Layout6x6_P0.4mm +UCBGA-36, 6x6 raster, 2.5x2.5mm package, pitch 0.4mm; https://www.latticesemi.com/view_document?document_id=213 +BGA 36 0.4 +0 +36 +36 +Package_BGA +UCBGA-49_3x3mm_Layout7x7_P0.4mm +UCBGA-49, 7x7 raster, 3x3mm package, pitch 0.4mm; https://www.latticesemi.com/view_document?document_id=213 +BGA 49 0.4 +0 +49 +49 +Package_BGA +UCBGA-81_4x4mm_Layout9x9_P0.4mm +UCBGA-81, 9x9 raster, 4x4mm package, pitch 0.4mm; https://www.latticesemi.com/view_document?document_id=213 +BGA 81 0.4 +0 +81 +81 +Package_BGA +UFBGA-15_3.0x3.0mm_Layout4x4_P0.65mm +UFBGA-15, 4x4, 3x3mm package, pitch 0.65mm +UFBGA-15 +0 +15 +15 +Package_BGA +UFBGA-32_4.0x4.0mm_Layout6x6_P0.5mm +UFBGA-32, 6x6, 4x4mm package, pitch 0.5mm +UFBGA-32 +0 +32 +32 +Package_BGA +UFBGA-64_5x5mm_Layout8x8_P0.5mm +UFBGA-64, 8x8 raster, 5x5mm package, pitch 0.5mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f051t8.pdf +BGA 64 0.5 +0 +64 +64 +Package_BGA +UFBGA-100_7x7mm_Layout12x12_P0.5mm +UFBGA-100, 12x12 raster, 7x7mm package, pitch 0.5mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f103tb.pdf +BGA 100 0.5 +0 +100 +100 +Package_BGA +UFBGA-132_7x7mm_Layout12x12_P0.5mm +UFBGA-132, 12x12 raster, 7x7mm package, pitch 0.5mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32l152zc.pdf +BGA 132 0.5 +0 +132 +132 +Package_BGA +UFBGA-132_7x7mm_P0.5mm +UFBGA 132 Pins, 0.5mm Pitch, 0.3mm Ball, http://www.st.com/resource/en/datasheet/stm32l486qg.pdf +ufbga bga small-pitch +0 +132 +132 +Package_BGA +UFBGA-144_7x7mm_Layout12x12_P0.5mm +UFBGA-144, 12x12 raster, 7x7mm package, pitch 0.5mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f446ze.pdf +BGA 144 0.5 +0 +144 +144 +Package_BGA +UFBGA-144_10x10mm_Layout12x12_P0.8mm +UFBGA-144, 12x12 raster, 10x10mm package, pitch 0.8mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f446ze.pdf +BGA 144 0.8 +0 +144 +144 +Package_BGA +UFBGA-169_7x7mm_Layout13x13_P0.5mm +UFBGA-169, 13x13 raster, 7x7mm package, pitch 0.5mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32f429ng.pdf +BGA 169 0.5 +0 +169 +169 +Package_BGA +UFBGA-201_10x10mm_Layout15x15_P0.65mm +UFBGA-201, 15x15 raster, 10x10mm package, pitch 0.65mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32f207vg.pdf +BGA 201 0.65 +0 +201 +201 +Package_BGA +VFBGA-49_5.0x5.0mm_Layout7x7_P0.65mm +VFBGA-49, 7x7, 5x5mm package, pitch 0.65mm +VFBGA-49 +0 +49 +49 +Package_BGA +VFBGA-100_7.0x7.0mm_Layout10x10_P0.65mm +VFBGA-100, 10x10, 7x7mm package, pitch 0.65mm +VFBGA-100 +0 +100 +100 +Package_BGA +WLP-4_0.73x0.73mm_Layout2x2_P0.35mm_Ball0.22mm_Pad0.2mm_NSMD +WLP-4, 2x2 raster, 0.73x0.73mm package, pitch 0.35mm; https://datasheets.maximintegrated.com/en/ds/MAX40200.pdf +BGA 4 0.35 +0 +4 +4 +Package_BGA +WLP-4_0.83x0.83mm_P0.4mm +WLP-4_0.83x0.83mm_P0.4mm https://pdfserv.maximintegrated.com/package_dwgs/21-100107.PDF, https://www.maximintegrated.com/en/app-notes/index.mvp/id/1891 +WLP-4 +0 +4 +4 +Package_BGA +WLP-4_0.86x0.86mm_P0.4mm +WLP-4_0.86x0.86mm_P0.4mm https://pdfserv.maximintegrated.com/package_dwgs/21-0612.PDF, https://www.maximintegrated.com/en/app-notes/index.mvp/id/1891 +WLP-4 +0 +4 +4 +Package_BGA +WLP-9_1.448x1.468mm_Layout3x3_P0.4mm_Ball0.27mm_Pad0.25mm +WLP-9, 1.448x1.468mm, 9 Ball, 3x3 Layout, 0.4mm Pitch, https://pdfserv.maximintegrated.com/package_dwgs/21-100168.PDF +BGA 9 0.4 +0 +9 +9 +Package_BGA +XBGA-121_10x10mm_Layout11x11_P0.8mm +XBGA-121, 11x11 raster, 10x10mm package, pitch 0.6mm; http://ww1.microchip.com/downloads/en/DeviceDoc/39969b.pdf +BGA 121 0.8 +0 +121 +121 +Package_BGA +XFBGA-36_3.5x3.5mm_Layout6x6_P0.5mm +XFBGA-36, https://www.nxp.com/docs/en/package-information/SOT1555-1.pdf +XFBGA-36 +0 +36 +36 +Package_BGA +XFBGA-64_5.0x5.0mm_Layout8x8_P0.5mm +XFBGA-64, https://www.nxp.com/docs/en/package-information/SOT1555-1.pdf +XFBGA-64 +0 +64 +64 +Package_BGA +XFBGA-121_8x8mm_Layout11x11_P0.65mm +XFBGA-121, https://www.nxp.com/docs/en/package-information/SOT1533-1.pdf +XFBGA-121 +0 +121 +121 +Package_BGA +Xilinx_CLG225 +Zynq-7000 BGA, 15x15 grid, 13x13mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=77, NSMD pad definition Appendix A +BGA 225 0.8 CLG225 +0 +225 +225 +Package_BGA +Xilinx_CLG400 +Zynq-7000 BGA, 20x20 grid, 17x17mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=78, NSMD pad definition Appendix A +BGA 400 0.8 CLG400 CL400 +0 +400 +400 +Package_BGA +Xilinx_CLG484_CLG485 +Zynq-7000 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=79, NSMD pad definition Appendix A +BGA 484 0.8 CLG484 CL484 CLG485 CL485 +0 +484 +484 +Package_BGA +Xilinx_CPG236 +Artix-7 BGA, 19x19 grid, 10x10mm package, 0.5mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=266, NSMD pad definition Appendix A +BGA 238 0.5 CP236 CPG236 +0 +238 +238 +Package_BGA +Xilinx_CPG238 +Artix-7 BGA, 19x19 grid, 10x10mm package, 0.5mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=267, NSMD pad definition Appendix A +BGA 238 0.5 CPG238 +0 +238 +238 +Package_BGA +Xilinx_CPGA196 +Spartan-7 BGA, 14x14 grid, 8x8mm package, 0.5mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=260, NSMD pad definition Appendix A +BGA 196 0.5 CPGA196 +0 +196 +196 +Package_BGA +Xilinx_CSG324 +Artix-7 BGA, 18x18 grid, 15x15mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=268, NSMD pad definition Appendix A +BGA 324 0.8 CS324 CSG324 +0 +324 +324 +Package_BGA +Xilinx_CSG325 +Artix-7 BGA, 18x18 grid, 15x15mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=268, NSMD pad definition Appendix A +BGA 324 0.8 CS325 CSG235 +0 +324 +324 +Package_BGA +Xilinx_CSGA225 +Spartan-7 BGA, 15x15 grid, 13x13mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=262, NSMD pad definition Appendix A +BGA 225 0.8 CSGA225 +0 +225 +225 +Package_BGA +Xilinx_CSGA324 +Spartan-7 BGA, 18x18 grid, 15x15mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=263, NSMD pad definition Appendix A +BGA 324 0.8 CSGA324 +0 +324 +324 +Package_BGA +Xilinx_FBG484 +Artix-7, Kintex-7 and Zynq-7000 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=271, ttps://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=281, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=82, NSMD pad definition Appendix A +BGA 484 1 FB484 FBG484 FBV484 +0 +484 +484 +Package_BGA +Xilinx_FBG676 +Artix-7, Kintex-7 and Zynq-7000 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=273, https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=284, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=84, NSMD pad definition Appendix A +BGA 676 1 FB676 FBG676 FBV676 +0 +676 +676 +Package_BGA +Xilinx_FBG900 +Kintex-7 BGA, 30x30 grid, 31x31mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=289, NSMD pad definition Appendix A +BGA 900 1 FB900 FBG900 FBV900 +0 +900 +900 +Package_BGA +Xilinx_FFG676 +Kintex-7 and Zynq-7000 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=292, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=88, NSMD pad definition Appendix A +BGA 676 1 FF676 FFG676 FFV676 +0 +676 +676 +Package_BGA +Xilinx_FFG900_FFG901 +Kintex-7 and Zynq-7000 BGA, 30x30 grid, 31x31mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=294, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=90, NSMD pad definition Appendix A +BGA 900 1 FF900 FFG900 FFV900 FF901 FFG901 FFV901 +0 +900 +900 +Package_BGA +Xilinx_FFG1156 +Artix-7, Kintex-7 and Zynq-7000 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=277, https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=296, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=91, NSMD pad definition Appendix A +BGA 1156 1 FF1156 FFG1156 FFV1156 +0 +1156 +1156 +Package_BGA +Xilinx_FFG1157_FFG1158 +Virtex-7 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=299, NSMD pad definition Appendix A +BGA 1156 1 FF1157 FFG1157 FFV1157 FF1158 FFG1158 FFV1158 +0 +1156 +1156 +Package_BGA +Xilinx_FFG1761 +Virtex-7 BGA, 42x42 grid, 42.5x42.5mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=300, NSMD pad definition Appendix A +BGA 1760 1 FF1761 FFG1761 +0 +1760 +1760 +Package_BGA +Xilinx_FFG1926_FFG1927_FFG1928_FFG1930 +Virtex-7 BGA, 44x44 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=303, NSMD pad definition Appendix A +BGA 1924 1 FF1926 FFG1926 FF1927 FFG1927 FFV1927 FF1928 FFG1928 FF1930 FFG1930 +0 +1924 +1924 +Package_BGA +Xilinx_FFV1761 +Virtex-7 BGA, 42x42 grid, 42.5x42.5mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=301, NSMD pad definition Appendix A +BGA 1760 1 FFV1761 +0 +1760 +1760 +Package_BGA +Xilinx_FGG484 +Artix-7 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=275, NSMD pad definition Appendix A +BGA 484 1 FG484 FGG484 +0 +484 +484 +Package_BGA +Xilinx_FGG676 +Artix-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=276, NSMD pad definition Appendix A +BGA 676 1 FG676 FGG676 +0 +676 +676 +Package_BGA +Xilinx_FGGA484 +Spartan-7 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=264, NSMD pad definition Appendix A +BGA 484 1 FGGA484 +0 +484 +484 +Package_BGA +Xilinx_FGGA676 +Spartan-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=265, NSMD pad definition Appendix A +BGA 676 1 FGGA676 +0 +676 +676 +Package_BGA +Xilinx_FHG1761 +Virtex-7 BGA, 42x42 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=302, NSMD pad definition Appendix A +BGA 1760 1 FH1761 FHG1761 +0 +1760 +1760 +Package_BGA +Xilinx_FLG1925_FLG1926_FLG1928_FLG1930 +Virtex-7 BGA, 44x44 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=304, NSMD pad definition Appendix A +BGA 1924 1 FL1925 FLG1925 FL1926 FLG1926 FL1928 FLG1928 FL1930 FLG1930 +0 +1924 +1924 +Package_BGA +Xilinx_FTG256 +Artix-7 BGA, 16x16 grid, 17x17mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=269, NSMD pad definition Appendix A +BGA 256 1 FT256 FTG256 +0 +256 +256 +Package_BGA +Xilinx_FTGB196 +Spartan-7 BGA, 14x14 grid, 15x15mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=261, NSMD pad definition Appendix A +BGA 196 1 FTGB196 +0 +196 +196 +Package_BGA +Xilinx_RB484 +Artix-7 and Zynq-7000 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=278, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=92, NSMD pad definition Appendix A +BGA 484 1 RB484 +0 +484 +484 +Package_BGA +Xilinx_RB676 +Artix-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=280, NSMD pad definition Appendix A +BGA 676 1 RB676 +0 +676 +676 +Package_BGA +Xilinx_RF676 +Kintex-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=297, NSMD pad definition Appendix A +BGA 676 1 RF676 +0 +676 +676 +Package_BGA +Xilinx_RF900 +Kintex-7 and Zynq-7000 BGA, 30x30 grid, 31x31mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=298, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=94, NSMD pad definition Appendix A +BGA 900 1 RF900 +0 +900 +900 +Package_BGA +Xilinx_RF1156 +Zynq-7000 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=95, NSMD pad definition Appendix A +BGA 1156 1 RF1156 +0 +1156 +1156 +Package_BGA +Xilinx_RF1157_RF1158 +Virtex-7 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=305, NSMD pad definition Appendix A +BGA 1156 1 RF1157 RF1158 +0 +1156 +1156 +Package_BGA +Xilinx_RF1761 +Virtex-7 BGA, 42x42 grid, 42.5x42.5mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=306, NSMD pad definition Appendix A +BGA 1760 1 RF1761 +0 +1760 +1760 +Package_BGA +Xilinx_RF1930 +Virtex-7 BGA, 44x44 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=307, NSMD pad definition Appendix A +BGA 1924 1 RF1930 +0 +1924 +1924 +Package_BGA +Xilinx_RFG676 +Zynq-7000 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=93, NSMD pad definition Appendix A +BGA 676 1 RF676 RFG676 +0 +676 +676 +Package_BGA +Xilinx_RS484 +Artix-7 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=279, NSMD pad definition Appendix A +BGA 484 0.8 RS484 +0 +484 +484 +Package_BGA +Xilinx_SBG484 +Artix-7 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=270, NSMD pad definition Appendix A +BGA 484 0.8 SB484 SBG484 SBV484 +0 +484 +484 +Package_BGA +Xilinx_SBG485 +Zynq-7000 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=80, NSMD pad definition Appendix A +BGA 484 0.8 SBG485 SBV485 +0 +484 +484 +Package_CSP +Analog_LFCSP-8-1EP_3x3mm_P0.5mm_EP1.53x1.85mm +LFCSP, exposed pad, Analog Devices (http://www.analog.com/media/en/technical-documentation/data-sheets/ADL5542.pdf) +LFCSP 8 0.5 +0 +12 +5 +Package_CSP +LFCSP-8-1EP_3x2mm_P0.5mm_EP1.6x1.65mm +LFCSP 8pin Pitch 0.5mm, http://www.analog.com/media/en/package-pcb-resources/package/57080735642908cp_8_4.pdf +LFCSP 8pin thermal pad 3x2mm Pitch 0.5mm +0 +9 +9 +Package_CSP +LFCSP-8-1EP_3x3mm_P0.5mm_EP1.45x1.74mm +LFCSP, 8 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-8/CP_8_13.pdf), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +LFCSP DFN_QFN +0 +13 +9 +Package_CSP +LFCSP-8_2x2mm_P0.5mm +LFCSP 8pin Pitch 0.5mm, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_8_6.pdf +LFCSP 8pin 2x2mm Pitch 0.5mm +0 +8 +8 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.3x1.3mm +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_21.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.3x1.3mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_21.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +26 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_22.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_22.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +26 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm +LFCSP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/HMC7992.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/HMC7992.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +26 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.854x1.854mm +16-Lead Lead Frame Chip Scale Package, 3x3mm, 0.5mm pitch, 1.854mm thermal pad (CP-16-22, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_16_22.pdf) +LFCSP 16 0.5 +0 +21 +17 +Package_CSP +LFCSP-16-1EP_4x4mm_P0.65mm_EP2.1x2.1mm +LFCSP, 16 pin, 4x4mm, 2.1mm sq pad (http://www.analog.com/media/en/technical-documentation/data-sheets/ADG633.pdf) +LFCSP 16 0.65 +0 +21 +17 +Package_CSP +LFCSP-16-1EP_4x4mm_P0.65mm_EP2.4x2.4mm +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/cp-16-40.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_4x4mm_P0.65mm_EP2.4x2.4mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/cp-16-40.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +31 +17 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.1x2.1mm +20-Lead Frame Chip Scale Package - 4x4x0.9 mm Body [LFCSP], (see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_20_6.pdf) +LFCSP 0.5 +0 +25 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +LFCSP, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/AD7682_7689.pdf), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +LFCSP DFN_QFN +0 +25 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +LFCSP, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/AD7682_7689.pdf), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +LFCSP DFN_QFN +0 +35 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +LFCSP, 20 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-20/CP_20_8.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +25 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +LFCSP, 20 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-20/CP_20_8.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +35 +21 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.3x2.3mm +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_14.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +29 +25 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.3x2.3mm_ThermalVias +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_14.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +39 +25 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +29 +25 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +39 +25 +Package_CSP +LFCSP-28-1EP_5x5mm_P0.5mm_EP3.14x3.14mm +LFCSP, 28 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-28/CP_28_10.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +33 +29 +Package_CSP +LFCSP-28-1EP_5x5mm_P0.5mm_EP3.14x3.14mm_ThermalVias +LFCSP, 28 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-28/CP_28_10.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +43 +29 +Package_CSP +LFCSP-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +LFCSP, 32 Pin (https://www.analog.com/media/en/package-pcb-resources/package/414143737956480539664569cp_32_2.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +42 +33 +Package_CSP +LFCSP-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +LFCSP, 32 Pin (https://www.analog.com/media/en/package-pcb-resources/package/414143737956480539664569cp_32_2.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +59 +33 +Package_CSP +LFCSP-32-1EP_5x5mm_P0.5mm_EP3.25x3.25mm +32-Lead Frame Chip Scale Package LFCSP (5mm x 5mm); (see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-32/CP_32_27.pdf +LFCSP 0.5 +0 +37 +33 +Package_CSP +LFCSP-48-1EP_7x7mm_P0.5mm_EP4.1x4.1mm +LFCSP, 48 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_48_5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +58 +49 +Package_CSP +LFCSP-48-1EP_7x7mm_P0.5mm_EP4.1x4.1mm_ThermalVias +LFCSP, 48 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_48_5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +75 +49 +Package_CSP +LFCSP-64-1EP_9x9mm_P0.5mm_EP5.21x5.21mm +LFCSP, 64 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_64_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +69 +65 +Package_CSP +LFCSP-64-1EP_9x9mm_P0.5mm_EP5.21x5.21mm_ThermalVias +LFCSP, 64 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_64_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +86 +65 +Package_CSP +LFCSP-72-1EP_10x10mm_P0.5mm_EP5.3x5.3mm +LFCSP, 72 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/ADAU1452_1451_1450.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +82 +73 +Package_CSP +LFCSP-72-1EP_10x10mm_P0.5mm_EP5.3x5.3mm_ThermalVias +LFCSP, 72 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/ADAU1452_1451_1450.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +99 +73 +Package_CSP +LFCSP-72-1EP_10x10mm_P0.5mm_EP6.15x6.15mm +72-Lead Frame Chip Scale Package - 10x10x0.9 mm Body [LFCSP]; (see https://www.intersil.com/content/dam/Intersil/documents/l72_/l72.10x10c.pdf) +LFCSP 0.5 +0 +77 +73 +Package_CSP +LFCSP-VQ-24-1EP_4x4mm_P0.5mm_EP2.642x2.642mm +LFCSP VQ, 24 pin, exposed pad, 4x4mm body, pitch 0.5mm (http://www.analog.com/media/en/package-pcb-resources/package/56702234806764cp_24_3.pdf, http://www.analog.com/media/en/technical-documentation/data-sheets/ADL5801.pdf) +LFCSP 0.5 +0 +29 +25 +Package_CSP +LFCSP-VQ-48-1EP_7x7mm_P0.5mm +LFCSP VQ, 48 pin, exposed pad, 7x7mm body (http://www.analog.com/media/en/technical-documentation/data-sheets/AD7951.pdf, http://www.analog.com/en/design-center/packaging-quality-symbols-footprints/symbols-and-footprints/AD7951.html) +LFCSP 48 +0 +49 +49 +Package_CSP +LFCSP-WD-8-1EP_3x3mm_P0.65mm_EP1.6x2.44mm +LFCSP-WD, 8 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/CP_8_19.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +15 +9 +Package_CSP +LFCSP-WD-8-1EP_3x3mm_P0.65mm_EP1.6x2.44mm_ThermalVias +LFCSP-WD, 8 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/CP_8_19.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +22 +9 +Package_CSP +LFCSP-WD-10-1EP_3x3mm_P0.5mm_EP1.64x2.38mm +LFCSP-WD, 10 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-10/CP_10_9.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +17 +11 +Package_CSP +LFCSP-WD-10-1EP_3x3mm_P0.5mm_EP1.64x2.38mm_ThermalVias +LFCSP-WD, 10 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-10/CP_10_9.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +24 +11 +Package_CSP +ST_WLCSP-25_Die425 +WLCSP-25, 5x5 raster, 2.097x2.493mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32l031f6.pdf +BGA 25 0.4 +0 +25 +25 +Package_CSP +ST_WLCSP-25_Die444 +WLCSP-25, 5x5 raster, 2.423x2.325mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f031k6.pdf +BGA 25 0.4 +0 +25 +25 +Package_CSP +ST_WLCSP-25_Die457 +WLCSP-25, 5x5 raster, 2.133x2.070mm package, pitch 0.4mm; see section 7.3 of http://www.st.com/resource/en/datasheet/stm32l011k3.pdf +BGA 25 0.4 +0 +25 +25 +Package_CSP +ST_WLCSP-36_Die417 +WLCSP-36, 6x6 raster, 2.61x2.88mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32l052t8.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-36_Die440 +WLCSP-36, 6x6 raster, 2.605x2.703mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f051t8.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-36_Die445 +WLCSP-36, 6x6 raster, 2.605x2.703mm package, pitch 0.4mm; see section 7.3 of http://www.st.com/resource/en/datasheet/stm32f042k6.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-36_Die458 +WLCSP-36, 6x6 raster, 2.553x2.579mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f410t8.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-49_Die423 +WLCSP-49, 7x7 raster, 2.965x2.965mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f401vc.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die431 +WLCSP-49, 7x7 raster, 2.999x3.185mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f411vc.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die433 +WLCSP-49, 7x7 raster, 3.029x3.029mm package, pitch 0.4mm; see section 7.1.1 of http://www.st.com/resource/en/datasheet/stm32f401ce.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die435 +WLCSP-49, 7x7 raster, 3.141x3.127mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/DM00257211.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die438 +WLCSP-49, 7x7 raster, 3.89x3.74mm package, pitch 0.5mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f303r8.pdf +BGA 49 0.5 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die439 +WLCSP-49, 7x7 raster, 3.417x3.151mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f301r8.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die447 +WLCSP-49, 7x7 raster, 3.294x3.258mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32l072kz.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die448 +WLCSP-49, 7x7 raster, 3.277x3.109mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f071v8.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-63_Die427 +WLCSP-63, 7x9 raster, 3.228x4.164mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32l151cc.pdf +BGA 63 0.4 +0 +63 +63 +Package_CSP +ST_WLCSP-64_Die414 +WLCSP-64, 8x8 raster, 4.466x4.395mm package, pitch 0.5mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f103ze.pdf +BGA 64 0.5 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die427 +WLCSP-64, 8x8 raster, 4.539x4.911mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l152zc.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die435 +WLCSP-64, 8x8 raster, 3.141x3.127mm package, pitch 0.35mm; see section 7.5 of http://www.st.com/resource/en/datasheet/DM00257211.pdf +BGA 64 0.35 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die436 +WLCSP-64, 8x8 raster, 4.539x4.911mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l152zd.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die441 +WLCSP-64, 8x8 raster, 3.623x3.651mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/DM00213872.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die442 +WLCSP-64, 8x8 raster, 3.347x3.585mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f091vb.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die462 +WLCSP-64, 8x8 raster, 3.357x3.657mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/DM00340475.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-66_Die411 +WLCSP-66, 9x9 raster, 3.639x3.971mm package, pitch 0.4mm; see section 7.2 of http://www.st.com/resource/en/datasheet/stm32f207vg.pdf +BGA 66 0.4 +0 +66 +66 +Package_CSP +ST_WLCSP-66_Die432 +WLCSP-66, 8x9 raster, 3.767x4.229mm package, pitch 0.4mm; see section 7.2 of http://www.st.com/resource/en/datasheet/stm32f378vc.pdf +BGA 66 0.4 +0 +66 +66 +Package_CSP +ST_WLCSP-72_Die415 +WLCSP-72, 9x9 raster, 4.4084x3.7594mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l476me.pdf +BGA 72 0.4 +0 +72 +72 +Package_CSP +ST_WLCSP-81_Die415 +WLCSP-81, 9x9 raster, 4.4084x3.7594mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32l476me.pdf +BGA 81 0.4 +0 +81 +81 +Package_CSP +ST_WLCSP-81_Die421 +WLCSP-81, 9x9 raster, 3.693x3.815mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32f446ze.pdf +BGA 81 0.4 +0 +81 +81 +Package_CSP +ST_WLCSP-81_Die463 +WLCSP-81, 9x9 raster, 4.039x3.951mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/DM00282249.pdf +BGA 81 0.4 +0 +81 +81 +Package_CSP +ST_WLCSP-90_Die413 +WLCSP-90, 10x9 raster, 4.223x3.969mm package, pitch 0.4mm; see section 6.1 of http://www.st.com/resource/en/datasheet/stm32f405og.pdf +BGA 90 0.4 +0 +90 +90 +Package_CSP +ST_WLCSP-100_Die422 +WLCSP-100, 10x10 raster, 4.201x4.663mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f302vc.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-100_Die446 +WLCSP-100, 10x10 raster, 4.775x5.041mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f303zd.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-100_Die452 +WLCSP-100, 10x10 raster, 4.201x4.663mm package, pitch 0.4mm; see section 7.7 of http://www.st.com/resource/en/datasheet/DM00330506.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-100_Die461 +WLCSP-100, 10x10 raster, 4.618x4.142mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/DM00284211.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-104_Die437 +WLCSP-104, 9x12 raster, 4.095x5.094mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l152ze.pdf +BGA 104 0.4 +0 +104 +104 +Package_CSP +ST_WLCSP-143_Die419 +WLCSP-143, 11x13 raster, 4.521x5.547mm package, pitch 0.4mm; see section 7.2 of http://www.st.com/resource/en/datasheet/stm32f429ng.pdf +BGA 143 0.4 +0 +143 +143 +Package_CSP +ST_WLCSP-143_Die449 +WLCSP-143, 11x13 raster, 4.539x5.849mm package, pitch 0.4mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f746zg.pdf +BGA 143 0.4 +0 +143 +143 +Package_CSP +ST_WLCSP-144_Die470 +WLCSP-144, 12x12 raster, 5.24x5.24mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/DM00366448.pdf +BGA 144 0.4 +0 +144 +144 +Package_CSP +ST_WLCSP-168_Die434 +WLCSP-168, 12x14 raster, 4.891x5.692mm package, pitch 0.4mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f469ni.pdf +BGA 168 0.4 +0 +168 +168 +Package_CSP +ST_WLCSP-180_Die451 +WLCSP-180, 13x14 raster, 5.537x6.095mm package, pitch 0.4mm; see section 6.6 of http://www.st.com/resource/en/datasheet/DM00273119.pdf +BGA 180 0.4 +0 +180 +180 +Package_CSP +WLCSP-6_1.4x1.0mm_P0.4mm +6pin Pitch 0.4mm +6pin Pitch 0.4mm WLCSP +0 +6 +6 +Package_CSP +WLCSP-8_1.58x1.63x0.35mm_Layout3x5_P0.35x0.4mm_Ball0.25mm_Pad0.25mm_NSMD +WLCSP/XFBGA 8-pin package, staggered pins, http://www.adestotech.com/wp-content/uploads/DS-AT25DF041B_040.pdf +WLCSP WLCSP-8 XFBGA XFBGA-8 CSP BGA Chip-Scale Glass-Top +0 +8 +8 +Package_CSP +WLCSP-12_1.56x1.56mm_P0.4mm +WLCSP 12 1.56x1.56 https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMM150-DS001-01.pdf +BMM150 WLCSP +0 +12 +12 +Package_CSP +WLCSP-12_1.403x1.555mm_P0.4mm_Stagger +WLCSP-12, 6x4 raster staggered array, 1.403x1.555mm package, pitch 0.4mm; http://ww1.microchip.com/downloads/en/devicedoc/atmel-8235-8-bit-avr-microcontroller-attiny20_datasheet.pdf#page=208 +CSP 12 0.2x0.346333 +0 +12 +12 +Package_CSP +WLCSP-16_4x4_B2.17x2.32mm_P0.5mm +WLCSP-16, http://www.nxp.com/documents/data_sheet/LPC1102_1104.pdf, http://www.nxp.com/assets/documents/data/en/application-notes/AN3846.pdf +WLCSP-16 NXP +0 +16 +16 +Package_CSP +WLCSP-20_1.934x2.434mm_Layout4x5_P0.4mm +WLCSP-20, 4x5 raster, 1.934x2.434mm package, pitch 0.4mm; see section 36.2.3 of http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-42363-SAM-D11_Datasheet.pdf +BGA 20 0.4 +0 +20 +20 +Package_CSP +WLCSP-20_1.994x1.94mm_Layout4x5_P0.4mm +WLCSP-20, https://www.nxp.com/docs/en/package-information/98ASA00539D.pdf +WLCSP-20 +0 +20 +20 +Package_CSP +WLCSP-20_1.994x1.609mm_Layout5x4_P0.4mm +WLCSP-20, https://www.nxp.com/docs/en/package-information/98ASA00676D.pdf +WLCSP-20 +0 +20 +20 +Package_CSP +WLCSP-36_2.82x2.67mm_Layout6x6_P0.4mm +WLCSP-36, https://www.nxp.com/docs/en/package-information/98ASA00949D.pdf +WLCSP-36 +0 +36 +36 +Package_CSP +WLCSP-36_2.374x2.459mm_Layout6x6_P0.35mm +WLCSP-36, https://www.nxp.com/docs/en/package-information/98ASA00604D.pdf +WLCSP-36 +0 +36 +36 +Package_CSP +WLCSP-56_3.170x3.444mm_Layout7x8_P0.4mm +WLCSP-56, 7x8 raster, 3.170x3.444mm package, pitch 0.4mm; see section 48.2.4 of http://ww1.microchip.com/downloads/en/DeviceDoc/DS60001479B.pdf +BGA 56 0.4 +0 +56 +56 +Package_CSP +WLCSP-81_4.41x3.76mm_P0.4mm +WLCSP-81, 9x9, 0.4mm Pitch, http://www.st.com/content/ccc/resource/technical/document/technical_note/92/30/3c/a1/4c/bb/43/6f/DM00103228.pdf/files/DM00103228.pdf/jcr:content/translations/en.DM00103228.pdf +WLCSP ST +0 +81 +81 +Package_CSP +pSemi_CSP-16_1.64x2.04mm_P0.4mm +pSemi CSP-16 1.64x2.04x0.285mm (http://www.psemi.com/pdf/datasheets/pe29101ds.pdf, http://www.psemi.com/pdf/app_notes/an77.pdf) +psemi csp 16 +0 +16 +16 +Package_CSP +pSemi_CSP-16_1.64x2.04mm_P0.4mm_Pad0.18mm +pSemi CSP-16 1.64x2.04x0.285mm (http://www.psemi.com/pdf/datasheets/pe29101ds.pdf, http://www.psemi.com/pdf/app_notes/an77.pdf) +psemi csp 16 +0 +16 +16 +Package_DFN_QFN +AMS_QFN-4-1EP_2x2mm_P0.95mm_EP0.7x1.6mm +UFD Package, 4-Lead Plastic QFN (2mm x 2mm), http://ams.com/eng/content/download/950231/2267959/483138 +QFN 0.95 +0 +6 +5 +Package_DFN_QFN +Cypress_QFN-56-1EP_8x8mm_P0.5mm_EP6.22x6.22mm_ThermalVias +56-Lead Plastic Quad Flat, No Lead Package (ML) - 8x8x0.9 mm Body [QFN] (see datasheet at http://www.cypress.com/file/138911/download and app note at http://www.cypress.com/file/140006/download) +QFN 0.5 +0 +87 +57 +Package_DFN_QFN +DFN-6-1EP_1.2x1.2mm_P0.4mm_EP0.3x0.94mm_PullBack +DFN, 6 Pin (http://www.onsemi.com/pub/Collateral/NCP133-D.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_2x1.8mm_P0.5mm_EP1.2x1.6mm +DFN, 6 Pin (https://www.diodes.com/assets/Package-Files/U-DFN2018-6.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +7 +Package_DFN_QFN +DFN-6-1EP_2x2mm_P0.5mm_EP0.6x1.37mm +DFN, 6 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-dfn/05081703_C_DC6.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_2x2mm_P0.5mm_EP0.61x1.42mm +DC6 Package; 6-Lead Plastic DFN (2mm x 2mm) (see Linear Technology DFN_6_05-08-1703.pdf) +DFN 0.5 +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_2x2mm_P0.65mm_EP1x1.6mm +6-Lead Plastic Dual Flat, No Lead Package (MA) - 2x2x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.65 +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_3x2mm_P0.5mm_EP1.65x1.35mm +DFN, 6 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-dfn/(DCB6)%20DFN%2005-08-1715%20Rev%20A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +7 +Package_DFN_QFN +DFN-6-1EP_3x3mm_P0.95mm_EP1.7x2.6mm +DFN6 3*3 MM, 0.95 PITCH; CASE 506AH-01 (see ON Semiconductor 506AH.PDF) +DFN 0.95 +0 +13 +7 +Package_DFN_QFN +DFN-6-1EP_3x3mm_P1mm_EP1.5x2.4mm +DFN, 6 Pin (https://www.silabs.com/documents/public/data-sheets/Si7020-A20.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +7 +Package_DFN_QFN +DFN-6_1.3x1.2mm_P0.4mm +6-Lead Plastic DFN (1.3mm x 1.2mm) +DFN 0.4 +0 +6 +6 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.6x1.2mm +DFN, 8 Pin (https://www.qorvo.com/products/d/da001879), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.7x1.3mm +DFN, 8 Pin (https://www.onsemi.com/pub/Collateral/NUF4401MN-D.PDF#page=6), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.3mm +DFN, 8 Pin (https://www.onsemi.com/pub/Collateral/NB3N551-D.PDF#page=7), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.5mm +DFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-8127-AVR-8-bit-Microcontroller-ATtiny4-ATtiny5-ATtiny9-ATtiny10_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.6mm +DFN, 8 Pin (https://www.st.com/resource/en/datasheet/lm2903.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +10 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP1.05x1.75mm +DFN8 2x2, 0.5P; CASE 506CN (see ON Semiconductor 506CN.PDF) +DFN 0.5 +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.45mm_EP0.64x1.38mm +DC8 Package 8-Lead Plastic DFN (2mm x 2mm) (see Linear Technology DFN_8_05-08-1719.pdf) +DFN 0.45 +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x3mm_P0.5mm_EP0.56x2.15mm +DFN, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/2451fg.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x3mm_P0.5mm_EP0.61x2.2mm +DDB Package; 8-Lead Plastic DFN (3mm x 2mm) (see Linear Technology DFN_8_05-08-1702.pdf) +DFN 0.5 +0 +12 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.3x1.5mm +8-Lead Plastic Dual Flat, No Lead Package (8MA2) - 2x3x0.6 mm Body [UDFN] (see Atmel-8815-SEEPROM-AT24CS01-02-Datasheet.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.7x1.4mm +DFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_DFN_2x3x0_9_MC_C04-123C.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.36x1.46mm +8-Lead Plastic Dual Flat, No Lead Package (8MA2) - 2x3x0.6 mm Body (http://ww1.microchip.com/downloads/en/DeviceDoc/20005010F.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.75x1.45mm +8-Lead Plastic Dual Flat, No Lead Package (MC) - 2x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.45mm_EP1.66x1.36mm +DCB Package 8-Lead Plastic DFN (2mm x 3mm) (see Linear Technology DFN_8_05-08-1718.pdf) +DFN 0.45 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x3mm_P0.5mm_EP1.66x2.38mm +DD Package; 8-Lead Plastic DFN (3mm x 3mm) (see Linear Technology DFN_8_05-08-1698.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x3mm_P0.65mm_EP1.7x2.05mm +DFN, 8 Pin (http://www.ixysic.com/home/pdfs.nsf/www/IX4426-27-28.pdf/$file/IX4426-27-28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x3mm_P0.65mm_EP1.55x2.4mm +8-Lead Plastic Dual Flat, No Lead Package (MF) - 3x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.65 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_4x4mm_P0.8mm_EP2.3x3.24mm +DFN, 8 Pin (https://www.st.com/resource/en/datasheet/ld1086.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_4x4mm_P0.8mm_EP2.5x3.6mm +8-Lead Plastic Dual Flat, No Lead Package (MD) - 4x4x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.8 +0 +15 +9 +Package_DFN_QFN +DFN-8-1EP_4x4mm_P0.8mm_EP2.39x2.21mm +8-Lead Plastic Dual Flat, No Lead Package (MD) - 4x4x0.9 mm Body [DFN] (http://www.onsemi.com/pub/Collateral/NCP4308-D.PDF) +DFN 0.8 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_6x5mm_P1.27mm_EP2x2mm +DD Package; 8-Lead Plastic DFN (6mm x 5mm) (see http://www.everspin.com/file/236/download) +dfn +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_6x5mm_P1.27mm_EP4x4mm +DD Package; 8-Lead Plastic DFN (6mm x 5mm) (see http://www.everspin.com/file/236/download) +dfn +0 +25 +9 +Package_DFN_QFN +DFN-8_2x2mm_P0.5mm +DFN8 2x2, 0.5P; No exposed pad - Ref http://pdfserv.maximintegrated.com/land_patterns/90-0349.PDF +DFN 0.5 +0 +8 +8 +Package_DFN_QFN +DFN-10-1EP_2x3mm_P0.5mm_EP0.64x2.4mm +DDB Package; 10-Lead Plastic DFN (3mm x 2mm) (see Linear Technology DFN_10_05-08-1722.pdf) +DFN 0.5 +0 +13 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.7x2.5mm +DFN, 10 Pin (https://www.monolithicpower.com/pub/media/document/MPQ2483_r1.05.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +15 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.55x2.48mm +10-Lead Plastic Dual Flat, No Lead Package (MF) - 3x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +15 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.65x2.38mm +DFN, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3471fb.pdf#page=15), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +15 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.65x2.38mm_ThermalVias +DFN, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3471fb.pdf#page=15), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +22 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.75x2.7mm +10-Lead Plastic Dual Flat No-Lead Package, 3x3mm Body (see Atmel Appnote 8826) +DFN 0.5 +0 +15 +11 +Package_DFN_QFN +DFN-10_2x2mm_P0.4mm +10-Lead Plastic DFN (2mm x 2mm) 0.40mm pitch +DFN 10 0.4mm +0 +10 +10 +Package_DFN_QFN +DFN-12-1EP_2x3mm_P0.45mm_EP0.64x2.4mm +DDB Package; 12-Lead Plastic DFN (3mm x 2mm) (see Linear Technology DFN_12_05-08-1723.pdf) +DFN 0.45 +0 +15 +13 +Package_DFN_QFN +DFN-12-1EP_3x3mm_P0.5mm_EP2.05x2.86mm +10-Lead Plastic Dual Flat, No Lead Package (MF) - 3x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +17 +13 +Package_DFN_QFN +DFN-12-1EP_3x3mm_P0.45mm_EP1.66x2.38mm +DD Package; 12-Lead Plastic DFN (3mm x 3mm) (see Linear Technology DFN_12_05-08-1725.pdf) +DFN 0.45 +0 +17 +13 +Package_DFN_QFN +DFN-12-1EP_3x4mm_P0.5mm_EP1.7x3.3mm +DE/UE Package; 12-Lead Plastic DFN (4mm x 3mm) (see Linear Technology DFN_12_05-08-1695.pdf) +DFN 0.5 +0 +21 +13 +Package_DFN_QFN +DFN-12-1EP_4x4mm_P0.5mm_EP2.66x3.38mm +DF Package; 12-Lead Plastic DFN (4mm x 4mm) (see Linear Technology 05081733_A_DF12.pdf) +DFN 0.5 +0 +21 +13 +Package_DFN_QFN +DFN-12-1EP_4x4mm_P0.65mm_EP2.64x3.54mm +DFN12, 4x4, 0.65P; CASE 506CE (see ON Semiconductor 506CE.PDF) +DFN 0.65 +0 +21 +13 +Package_DFN_QFN +DFN-14-1EP_3x3mm_P0.4mm_EP1.78x2.35mm +DD Package; 14-Lead Plastic DFN (3mm x 3mm) (http://pdfserv.maximintegrated.com/land_patterns/90-0063.PDF) +DFN 0.40 +0 +19 +15 +Package_DFN_QFN +DFN-14-1EP_3x4.5mm_P0.65mm_EP1.65x4.25mm +14-lead very thin plastic quad flat, 3.0x4.5mm size, 0.65mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/14L_VDFN_4_5x3_0mm_JHA_C041198A.pdf) +VDFN DFN 0.65mm +0 +23 +15 +Package_DFN_QFN +DFN-14-1EP_3x4.5mm_P0.65mm_EP1.65x4.25mm_ThermalVias +14-lead very thin plastic quad flat, 3.0x4.5mm size, 0.65mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/14L_VDFN_4_5x3_0mm_JHA_C041198A.pdf) +VDFN DFN 0.65mm +0 +33 +15 +Package_DFN_QFN +DFN-14-1EP_3x4mm_P0.5mm_EP1.7x3.3mm +DE Package; 14-Lead Plastic DFN (4mm x 3mm) (see Linear Technology DFN_14_05-08-1708.pdf) +DFN 0.5 +0 +23 +15 +Package_DFN_QFN +DFN-14-1EP_4x4mm_P0.5mm_EP2.86x3.6mm +DFN14, 4x4, 0.5P; CASE 506CM (see ON Semiconductor 506CM.PDF) +DFN 0.5 +0 +23 +15 +Package_DFN_QFN +DFN-16-1EP_3x4mm_P0.45mm_EP1.7x3.3mm +DE Package; 16-Lead Plastic DFN (4mm x 3mm) (see Linear Technology DFN_16_05-08-1732.pdf) +DFN 0.45 +0 +25 +17 +Package_DFN_QFN +DFN-16-1EP_3x5mm_P0.5mm_EP1.66x4.4mm +DHC Package; 16-Lead Plastic DFN (5mm x 3mm) (see Linear Technology DFN_16_05-08-1706.pdf) +DFN 0.5 +0 +27 +17 +Package_DFN_QFN +DFN-16-1EP_4x5mm_P0.5mm_EP2.44x4.34mm +DHD Package; 16-Lead Plastic DFN (5mm x 4mm) (see Linear Technology 05081707_A_DHD16.pdf) +DFN 0.5 +0 +25 +17 +Package_DFN_QFN +DFN-16-1EP_5x5mm_P0.5mm_EP3.46x4mm +DH Package; 16-Lead Plastic DFN (5mm x 5mm) (see Linear Technology DFN_16_05-08-1709.pdf) +DFN 0.5 +0 +26 +17 +Package_DFN_QFN +DFN-18-1EP_3x5mm_P0.5mm_EP1.66x4.4mm +DHC Package; 18-Lead Plastic DFN (5mm x 3mm) (see Linear Technology 05081955_0_DHC18.pdf) +DFN 0.5 +0 +29 +19 +Package_DFN_QFN +DFN-18-1EP_4x5mm_P0.5mm_EP2.44x4.34mm +DHD Package; 18-Lead Plastic DFN (5mm x 4mm) (see Linear Technology DFN_18_05-08-1778.pdf) +DFN 0.5 +0 +27 +19 +Package_DFN_QFN +DFN-20-1EP_5x6mm_P0.5mm_EP3.24x4.24mm +DFN20, 6x5, 0.5P; CASE 505AB (see ON Semiconductor 505AB.PDF) +DFN 0.5 +0 +33 +21 +Package_DFN_QFN +DFN-22-1EP_5x6mm_P0.5mm_EP3.14x4.3mm +DFN22 6*5*0.9 MM, 0.5 P; CASE 506AF\xe2\x88\x9201 (see ON Semiconductor 506AF.PDF) +DFN 0.5 +0 +35 +23 +Package_DFN_QFN +DFN-24-1EP_4x7mm_P0.5mm_EP2.64x6.44mm +DKD Package; 24-Lead Plastic DFN (7mm x 4mm) (see Linear Technology DFN_24_05-08-1864.pdf) +DFN 0.5 +0 +35 +25 +Package_DFN_QFN +DFN-32-1EP_4x7mm_P0.4mm_EP2.64x6.44mm +DKD Package; 32-Lead Plastic DFN (7mm x 4mm) (see Linear Technology DFN_32_05-08-1734.pdf) +DFN 0.4 +0 +43 +33 +Package_DFN_QFN +DFN-44-1EP_5x8.9mm_P0.4mm_EP3.7x8.4mm +DFN44 8.9x5, 0.4P; CASE 506BU-01 (see ON Semiconductor 506BU.PDF) +DFN 0.4 +0 +63 +45 +Package_DFN_QFN +DFN-S-8-1EP_6x5mm_P1.27mm +8-Lead Plastic Dual Flat, No Lead Package (MF) - 6x5 mm Body [DFN-S] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 1.27 +0 +16 +9 +Package_DFN_QFN +Diodes_DFN1006-3 +DFN package size 1006 3 pins +DFN package size 1006 3 pins +0 +3 +3 +Package_DFN_QFN +Diodes_UDFN-10_1.0x2.5mm_P0.5mm +U-DFN2510-10 package used by Diodes Incorporated (https://www.diodes.com/assets/Package-Files/U-DFN2510-10-Type-CJ.pdf) +UDFN-10 U-DFN2510-10 Diodes +0 +10 +10 +Package_DFN_QFN +Diodes_UDFN2020-6_Type-F +U-DFN2020-6 (Type F) (https://www.diodes.com/assets/Package-Files/U-DFN2020-6-Type-F.pdf) +U-DFN2020-6 (Type F) +0 +8 +8 +Package_DFN_QFN +HVQFN-16-1EP_3x3mm_P0.5mm_EP1.5x1.5mm +HVQFN, 16 Pin (https://www.nxp.com/docs/en/package-information/SOT758-1.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +21 +17 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +29 +25 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +39 +25 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +34 +25 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +39 +25 +Package_DFN_QFN +Infineon_MLPQ-16-14-1EP_4x4mm_P0.5mm +MLPQ 32 leads, 7x7mm, 0.127mm stencil (https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +mlpq 32 7x7mm +0 +19 +15 +Package_DFN_QFN +Infineon_MLPQ-40-32-1EP_7x7mm_P0.5mm +MLPQ 32 leads, 7x7mm, 0.127mm stencil (https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +mlpq 32 7x7mm +0 +76 +33 +Package_DFN_QFN +Infineon_MLPQ-48-1EP_7x7mm_P0.5mm_EP5.55x5.55mm +MLPQ 48 leads, 7x7mm (https://www.infineon.com/dgdl/irs2093mpbf.pdf?fileId=5546d462533600a401535675fb892793) +mlpq 32 7x7mm +0 +113 +49 +Package_DFN_QFN +Infineon_MLPQ-48-1EP_7x7mm_P0.5mm_Pad5.15x5.15mm +MLPQ 48 leads, 7x7mm (https://www.infineon.com/dgdl/irs2052mpbf.pdf?fileId=5546d462533600a401535675d3b32788) +mlpq 32 7x7mm +0 +117 +49 +Package_DFN_QFN +Infineon_MLPQ-48-1EP_7x7mm_P0.5mm_Pad5.55x5.55mm +MLPQ 48 leads, 7x7mm (https://www.infineon.com/dgdl/irs2093mpbf.pdf?fileId=5546d462533600a401535675fb892793) +mlpq 32 7x7mm +0 +117 +49 +Package_DFN_QFN +Infineon_PQFN-22-15-4EP_6x5mm_P0.65mm +PQFN 22 leads, 5x6mm, 0.127mm stencil (https://www.infineon.com/dgdl/ir4301.pdf?fileId=5546d462533600a4015355d5fc691819, https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +pqfn 22 5x6mm +0 +56 +15 +Package_DFN_QFN +Infineon_PQFN-44-31-5EP_7x7mm_P0.5mm +PQFN 44 leads, 7x7mm, 0.127mm stencil (https://www.infineon.com/dgdl/ir4302.pdf?fileId=5546d462533600a4015355d602a9181d, https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +pqfn 44 7x7mm +0 +125 +27 +Package_DFN_QFN +Linear_DE14MA +14-Lead Plastic DFN, 4mm x 3mm (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-dfn/05081731_C_DE14MA.pdf) +DFN 0.5 +0 +14 +14 +Package_DFN_QFN +Linear_UGK52_QFN-46-52 +Linear UKG52(46) package, QFN-52-1EP variant (see http://cds.linear.com/docs/en/datasheet/3886fe.pdf) +QFN 0.5 +0 +62 +47 +Package_DFN_QFN +MLF-6-1EP_1.6x1.6mm_P0.5mm_EP0.5x1.26mm +MLF, 6 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/mic5353.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +MLF NoLead +0 +9 +7 +Package_DFN_QFN +MLF-8-1EP_3x3mm_P0.65mm_EP1.55x2.3mm +8-Pin ePad 3mm x 3mm MLF - 3x3x0.85 mm Body (see Microchip datasheet http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf) +DFN MLF 0.65 +0 +12 +9 +Package_DFN_QFN +MLF-8-1EP_3x3mm_P0.65mm_EP1.55x2.3mm_ThermalVias +8-Pin ePad 3mm x 3mm MLF - 3x3x0.85 mm Body (see Microchip datasheet http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf) +DFN MLF 0.65 +0 +15 +9 +Package_DFN_QFN +MLF-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +MLF, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=263), generated with kicad-footprint-generator ipc_noLead_generator.py +MLF NoLead +0 +25 +21 +Package_DFN_QFN +MLF-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +MLF, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=263), generated with kicad-footprint-generator ipc_noLead_generator.py +MLF NoLead +0 +30 +21 +Package_DFN_QFN +MLPQ-16-1EP_4x4mm_P0.65mm_EP2.8x2.8mm +Micro Leadframe Package, 16 pin with exposed pad +MLPQ- 0.65 +0 +21 +17 +Package_DFN_QFN +Micrel_MLF-8-1EP_2x2mm_P0.5mm_EP0.8x1.3mm_ThermalVias +http://ww1.microchip.com/downloads/en/DeviceDoc/mic2290.pdf +mlf 8 2x2 mm +0 +14 +9 +Package_DFN_QFN +Microchip_8E-16 +16-Lead Quad Flat, No Lead Package (8E) - 4x4x0.9 mm Body [UQFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN Microchip 8E 16 +0 +20 +17 +Package_DFN_QFN +Microchip_DRQFN-44-1EP_5x5mm_P0.7mm_EP2.65x2.65mm +QFN, 44 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/44L_VQFN_5x5mm_Dual_Row_%5BS3B%5D_C04-21399a.pdf) +QFN dual row +0 +49 +45 +Package_DFN_QFN +Microchip_DRQFN-44-1EP_5x5mm_P0.7mm_EP2.65x2.65mm_ThermalVias +QFN, 44 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/44L_VQFN_5x5mm_Dual_Row_%5BS3B%5D_C04-21399a.pdf) +QFN dual row +0 +59 +45 +Package_DFN_QFN +Microchip_DRQFN-64-1EP_7x7mm_P0.65mm_EP4.1x4.1mm +QFN, 64 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_7x7_Dual_Row_%5BSVB%5D_C04-21420a.pdf) +QFN dual row +0 +74 +65 +Package_DFN_QFN +Microchip_DRQFN-64-1EP_7x7mm_P0.65mm_EP4.1x4.1mm_ThermalVias +QFN, 64 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_7x7_Dual_Row_%5BSVB%5D_C04-21420a.pdf) +QFN dual row +0 +91 +65 +Package_DFN_QFN +Microsemi_QFN-40-32-2EP_6x8mm_P0.5mm +40-Lead (32-Lead Populated) Plastic Quad Flat, No Lead Package - 6x8x0.9mm Body (https://www.microsemi.com/document-portal/doc_download/131677-pd70224-data-sheet) +QFN 0.5 +0 +92 +34 +Package_DFN_QFN +Mini-Circuits_DL805 +https://ww2.minicircuits.com/case_style/DL805.pdf +RF Switch +0 +11 +9 +Package_DFN_QFN +Mini-Circuits_FG873-4_3x3mm +Mini Circuits Case style FG (https://ww2.minicircuits.com/case_style/FG873.pdf) +FG873 +0 +4 +4 +Package_DFN_QFN +Nordic_AQFN-73-1EP_7x7mm_P0.5mm +http://infocenter.nordicsemi.com/index.jsp?topic=%2Fcom.nordic.infocenter.nrf52%2Fdita%2Fnrf52%2Fchips%2Fnrf52840.html +AQFN 7mm +0 +78 +74 +Package_DFN_QFN +OnSemi_DFN-8_2x2mm_P0.5mm +DFN8 2x2, 0.5P (https://www.onsemi.com/pub/Collateral/511AT.PDF) +DFN 0.5 +0 +8 +8 +Package_DFN_QFN +OnSemi_UDFN-8_1.2x1.8mm_P0.4mm +8-Lead Plastic Dual Flat, No Lead Package, 1.2x1.8x1.55 mm Body [UDFN] (See http://www.onsemi.com/pub/Collateral/NLSV2T244-D.PDF) +dfn udfn dual flat +0 +8 +8 +Package_DFN_QFN +OnSemi_VCT-28_3.5x3.5mm_P0.4mm +OnSemi VCT, 28 Pin (http://www.onsemi.com/pub/Collateral/601AE.PDF), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +OnSemi VCT DFN_QFN +0 +28 +28 +Package_DFN_QFN +Panasonic_HQFN-16-1EP_4x4mm_P0.65mm_EP2.9x2.9mm +Panasonic HQFN-16, 4x4x0.85mm (https://industrial.panasonic.com/content/data/SC/ds/ds7/c0/PKG_HQFN016-A-0404XZL_EN.pdf) +panasonic hqfn +0 +37 +17 +Package_DFN_QFN +Panasonic_HSON-8_8x8mm_P2.00mm +Panasonic HSON-8, 8x8x1.25mm (https://industrial.panasonic.com/content/data/SC/ds/ds7/c0/PKG_HSON008-A-0808XXI_EN.pdf) +panasonic hson +0 +27 +9 +Package_DFN_QFN +QFN-12-1EP_3x3mm_P0.5mm_EP1.65x1.65mm +QFN, 12 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_12_%2005-08-1855.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +17 +13 +Package_DFN_QFN +QFN-12-1EP_3x3mm_P0.5mm_EP1.65x1.65mm_ThermalVias +QFN, 12 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_12_%2005-08-1855.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +22 +13 +Package_DFN_QFN +QFN-12-1EP_3x3mm_P0.51mm_EP1.45x1.45mm +QFN, 12 Pin (https://ww2.minicircuits.com/case_style/DQ1225.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +17 +13 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm +QFN, 16 Pin (https://www.st.com/resource/en/datasheet/tsv521.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm_ThermalVias +QFN, 16 Pin (http://www.cypress.com/file/46236/download), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +QFN DFN_QFN +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.9x1.9mm +QFN, 16 Pin (https://www.nxp.com/docs/en/package-information/98ASA00525D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.9x1.9mm_ThermalVias +QFN, 16 Pin (https://www.nxp.com/docs/en/package-information/98ASA00525D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm +QFN, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm_ThermalVias +QFN, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm +QFN, 16 Pin (https://www.onsemi.com/pub/Collateral/NCN4555-D.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm_ThermalVias +QFN, 16 Pin (https://www.onsemi.com/pub/Collateral/NCN4555-D.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.5mm_EP2.45x2.45mm +QFN, 16 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/isl8117.pdf#page=22), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.5mm_EP2.45x2.45mm_ThermalVias +QFN, 16 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/isl8117.pdf#page=22), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.1x2.1mm +QFN, 16 Pin (http://www.thatcorp.com/datashts/THAT_1580_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.1x2.1mm_ThermalVias +QFN, 16 Pin (http://www.thatcorp.com/datashts/THAT_1580_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.5x2.5mm +QFN, 16 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=266), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.5x2.5mm_ThermalVias +QFN, 16 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=266), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm +QFN, 16 Pin (https://www.allegromicro.com/~/media/Files/Datasheets/A4403-Datasheet.ashx), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm_PullBack +QFN, 16 Pin (https://ams.com/documents/20143/36005/AS5055A_DS000304_2-00.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm_PullBack_ThermalVias +QFN, 16 Pin (https://ams.com/documents/20143/36005/AS5055A_DS000304_2-00.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm_ThermalVias +QFN, 16 Pin (https://www.allegromicro.com/~/media/Files/Datasheets/A4403-Datasheet.ashx), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.15x2.15mm +QFN, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4001f.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.15x2.15mm_ThermalVias +QFN, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4001f.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_5x5mm_P0.8mm_EP2.7x2.7mm +QFN, 16 Pin (http://www.intersil.com/content/dam/Intersil/documents/l16_/l16.5x5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_5x5mm_P0.8mm_EP2.7x2.7mm_ThermalVias +QFN, 16 Pin (http://www.intersil.com/content/dam/Intersil/documents/l16_/l16.5x5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-20-1EP_3.5x3.5mm_P0.5mm_EP2x2mm +QFN, 20 Pin (http://www.ti.com/lit/ml/mpqf239/mpqf239.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3.5x3.5mm_P0.5mm_EP2x2mm_ThermalVias +QFN, 20 Pin (http://www.ti.com/lit/ml/mpqf239/mpqf239.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.4mm_EP1.65x1.65mm +QFN, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3553fc.pdf#page=34), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.4mm_EP1.65x1.65mm_ThermalVias +QFN, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3553fc.pdf#page=34), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.45mm_EP1.6x1.6mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8235-8-bit-avr-microcontroller-attiny20_datasheet.pdf#page=212), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.45mm_EP1.6x1.6mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8235-8-bit-avr-microcontroller-attiny20_datasheet.pdf#page=212), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_3x4mm_P0.5mm_EP1.65x2.65mm +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3x4mm_P0.5mm_EP1.65x2.65mm_ThermalVias +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +32 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=274), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=274), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc2535.pdf#page=164), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc2535.pdf#page=164), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.7x2.7mm +QFN, 20 Pin (https://www.silabs.com/documents/public/data-sheets/Si5351-B.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.7x2.7mm_ThermalVias +QFN, 20 Pin (https://www.silabs.com/documents/public/data-sheets/Si5351-B.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_4x5mm_P0.5mm_EP2.65x3.65mm +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1711.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +27 +21 +Package_DFN_QFN +QFN-20-1EP_4x5mm_P0.5mm_EP2.65x3.65mm_ThermalVias +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1711.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +40 +21 +Package_DFN_QFN +QFN-20-1EP_5x5mm_P0.65mm_EP3.35x3.35mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=276), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_5x5mm_P0.65mm_EP3.35x3.35mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=276), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +21 +Package_DFN_QFN +QFN-24-1EP_3x3mm_P0.4mm_EP1.75x1.6mm +QFN, 24 Pin (https://www.invensense.com/wp-content/uploads/2015/02/PS-MPU-9250A-01-v1.1.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_3x3mm_P0.4mm_EP1.75x1.6mm_ThermalVias +QFN, 24 Pin (https://www.invensense.com/wp-content/uploads/2015/02/PS-MPU-9250A-01-v1.1.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +34 +25 +Package_DFN_QFN +QFN-24-1EP_3x4mm_P0.4mm_EP1.65x2.65mm +QFN, 24 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +25 +Package_DFN_QFN +QFN-24-1EP_3x4mm_P0.4mm_EP1.65x2.65mm_ThermalVias +QFN, 24 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +QFN, 24 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=278), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +QFN, 24 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=278), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.6mm +QFN, 24 Pin (https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.6mm_ThermalVias +QFN, 24 Pin (https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.7mm +QFN, 24 Pin (http://www.alfarzpp.lv/eng/sc/AS3330.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.7mm_ThermalVias +QFN, 24 Pin (http://www.alfarzpp.lv/eng/sc/AS3330.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm +QFN, 24 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/hmc431.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_ThermalVias +QFN, 24 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/hmc431.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.65x2.65mm +QFN, 24 Pin (http://www.cypress.com/file/46236/download), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.65x2.65mm_ThermalVias +QFN, 24 Pin (http://www.cypress.com/file/46236/download), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x5mm_P0.5mm_EP2.65x3.65mm +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_24_05-08-1696.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +25 +Package_DFN_QFN +QFN-24-1EP_4x5mm_P0.5mm_EP2.65x3.65mm_ThermalVias +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_24_05-08-1696.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +44 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.2x3.2mm +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UH24)%20QFN%2005-08-1747%20Rev%20A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.2x3.2mm_ThermalVias +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UH24)%20QFN%2005-08-1747%20Rev%20A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +51 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.4x3.4mm +QFN, 24 Pin (http://www.thatcorp.com/datashts/THAT_5173_Datasheet.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.4x3.4mm_ThermalVias +QFN, 24 Pin (http://www.thatcorp.com/datashts/THAT_5173_Datasheet.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.6x3.6mm +QFN, 24 Pin (https://www.nxp.com/docs/en/package-information/98ASA00734D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +34 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.6x3.6mm_ThermalVias +QFN, 24 Pin (https://www.nxp.com/docs/en/package-information/98ASA00734D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +67 +25 +Package_DFN_QFN +QFN-28-1EP_3x6mm_P0.5mm_EP1.7x4.75mm +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081926_0_UDE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +29 +Package_DFN_QFN +QFN-28-1EP_3x6mm_P0.5mm_EP1.7x4.75mm_ThermalVias +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081926_0_UDE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +53 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.3x2.3mm +QFN, 28 Pin (http://www.issi.com/WW/pdf/31FL3731.pdf#page=21), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.3x2.3mm_ThermalVias +QFN, 28 Pin (http://www.issi.com/WW/pdf/31FL3731.pdf#page=21), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.4x2.4mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=280), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.4x2.4mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=280), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.6x2.6mm +QFN, 28 Pin (package code T2844-1; https://pdfserv.maximintegrated.com/package_dwgs/21-0139.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.6x2.6mm_ThermalVias +QFN, 28 Pin (package code T2844-1; https://pdfserv.maximintegrated.com/package_dwgs/21-0139.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x5mm_P0.5mm_EP2.65x3.65mm +QFN, 28 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/3555fe.pdf#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +29 +Package_DFN_QFN +QFN-28-1EP_4x5mm_P0.5mm_EP2.65x3.65mm_ThermalVias +QFN, 28 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/3555fe.pdf#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +48 +29 +Package_DFN_QFN +QFN-28-1EP_5x5mm_P0.5mm_EP3.35x3.35mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=283), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +29 +Package_DFN_QFN +QFN-28-1EP_5x5mm_P0.5mm_EP3.35x3.35mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=283), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +55 +29 +Package_DFN_QFN +QFN-28-1EP_5x6mm_P0.5mm_EP3.65x4.65mm +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081932_0_UHE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +41 +29 +Package_DFN_QFN +QFN-28-1EP_5x6mm_P0.5mm_EP3.65x4.65mm_ThermalVias +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081932_0_UHE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +62 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.8x4.8mm +QFN, 28 Pin (https://www.semtech.com/uploads/documents/sx1272.pdf#page=125), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.8x4.8mm_ThermalVias +QFN, 28 Pin (https://www.semtech.com/uploads/documents/sx1272.pdf#page=125), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +71 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.25x4.25mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=289), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.25x4.25mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=289), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +71 +29 +Package_DFN_QFN +QFN-28_4x4mm_P0.5mm +QFN, 28 Pin (http://www.st.com/resource/en/datasheet/stm32f031k6.pdf#page=90), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +28 +28 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.9x2.9mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8153-8-and-16-bit-avr-microcontroller-xmega-e-atxmega8e5-atxmega16e5-atxmega32e5_datasheet.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.9x2.9mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8153-8-and-16-bit-avr-microcontroller-xmega-e-atxmega8e5-atxmega16e5-atxmega32e5_datasheet.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +33 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.65x2.65mm +QFN, 32 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/l32.4x4a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.65x2.65mm_ThermalVias +QFN, 32 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/l32.4x4a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.3x3.3mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002164B.pdf#page=68), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.3x3.3mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002164B.pdf#page=68), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.6x3.6mm +QFN, 32 Pin (http://infocenter.nordicsemi.com/pdf/nRF52810_PS_v1.1.pdf#page=468), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.6x3.6mm_ThermalVias +QFN, 32 Pin (http://infocenter.nordicsemi.com/pdf/nRF52810_PS_v1.1.pdf#page=468), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.7x3.7mm +QFN, 32 Pin (https://www.espressif.com/sites/default/files/documentation/0a-esp8285_datasheet_en.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.7x3.7mm_ThermalVias +QFN, 32 Pin (https://www.espressif.com/sites/default/files/documentation/0a-esp8285_datasheet_en.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.45x3.45mm +QFN, 32 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_32_05-08-1693.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.45x3.45mm_ThermalVias +QFN, 32 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_32_05-08-1693.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.65x3.65mm +QFN, 32 Pin (https://www.exar.com/ds/mxl7704.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.65x3.65mm_ThermalVias +QFN, 32 Pin (https://www.exar.com/ds/mxl7704.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.7x4.7mm +QFN, 32 Pin (https://www.nxp.com/docs/en/data-sheet/LPC111X.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.7x4.7mm_ThermalVias +QFN, 32 Pin (https://www.nxp.com/docs/en/data-sheet/LPC111X.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.65x4.65mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-8209-8-bit%20AVR%20ATmega16M1-32M1-64M1_Datasheet.pdf#page=426), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.65x4.65mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-8209-8-bit%20AVR%20ATmega16M1-32M1-64M1_Datasheet.pdf#page=426), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP5.4x5.4mm +QFN, 32 Pin (http://www.thatcorp.com/datashts/THAT_5171_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP5.4x5.4mm_ThermalVias +QFN, 32 Pin (http://www.thatcorp.com/datashts/THAT_5171_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +33 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.1mm +QFN, 36 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.1mm_ThermalVias +QFN, 36 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +56 +37 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.6mm +QFN, 36 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UHE36)%20QFN%2005-08-1876%20Rev%20%C3%98.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +37 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.6mm_ThermalVias +QFN, 36 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UHE36)%20QFN%2005-08-1876%20Rev%20%C3%98.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +56 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP3.7x3.7mm +QFN, 36 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/36L_QFN_6x6_with_3_7x3_7_EP_Punch_Dimpled_4E_C04-0241A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP3.7x3.7mm_ThermalVias +QFN, 36 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/36L_QFN_6x6_with_3_7x3_7_EP_Punch_Dimpled_4E_C04-0241A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +63 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP4.1x4.1mm +QFN, 36 Pin (www.st.com/resource/en/datasheet/stm32f101t6.pdf#page=72), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP4.1x4.1mm_ThermalVias +QFN, 36 Pin (www.st.com/resource/en/datasheet/stm32f101t6.pdf#page=72), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +63 +37 +Package_DFN_QFN +QFN-38-1EP_4x6mm_P0.4mm_EP2.65x4.65mm +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1750.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +39 +Package_DFN_QFN +QFN-38-1EP_4x6mm_P0.4mm_EP2.65x4.65mm_ThermalVias +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1750.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +56 +39 +Package_DFN_QFN +QFN-38-1EP_5x7mm_P0.5mm_EP3.15x5.15mm +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1701.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +54 +39 +Package_DFN_QFN +QFN-38-1EP_5x7mm_P0.5mm_EP3.15x5.15mm_ThermalVias +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1701.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +63 +39 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.6x3.6mm +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=297), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.6x3.6mm_ThermalVias +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=297), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +67 +41 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm +QFN, 40 Pin (http://www.issi.com/WW/pdf/31FL3736.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm_ThermalVias +QFN, 40 Pin (http://www.issi.com/WW/pdf/31FL3736.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +67 +41 +Package_DFN_QFN +QFN-40-1EP_6x6mm_P0.5mm_EP4.6x4.6mm +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=295), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +57 +41 +Package_DFN_QFN +QFN-40-1EP_6x6mm_P0.5mm_EP4.6x4.6mm_ThermalVias +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=295), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +83 +41 +Package_DFN_QFN +QFN-42-1EP_5x6mm_P0.4mm_EP3.7x4.7mm +QFN, 42 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081875_0_UHE42.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +55 +43 +Package_DFN_QFN +QFN-42-1EP_5x6mm_P0.4mm_EP3.7x4.7mm_ThermalVias +QFN, 42 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081875_0_UHE42.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +76 +43 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.2x5.2mm +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/2512S.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +61 +45 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.2x5.2mm_ThermalVias +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/2512S.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +87 +45 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.15x5.15mm +QFN, 44 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_44_05-08-1763.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +61 +45 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.15x5.15mm_ThermalVias +QFN, 44 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_44_05-08-1763.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +87 +45 +Package_DFN_QFN +QFN-44-1EP_8x8mm_P0.65mm_EP6.45x6.45mm +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/39935c.pdf#page=152), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +70 +45 +Package_DFN_QFN +QFN-44-1EP_8x8mm_P0.65mm_EP6.45x6.45mm_ThermalVias +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/39935c.pdf#page=152), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +45 +Package_DFN_QFN +QFN-44-1EP_9x9mm_P0.65mm_EP7.5x7.5mm +44-Lead Plastic Quad Flat, No Lead Package - 9x9 mm Body [QFN]; see section 10.3 of https://www.parallax.com/sites/default/files/downloads/P8X32A-Propeller-Datasheet-v1.4.0_0.pdf +QFN 0.65 +0 +49 +45 +Package_DFN_QFN +QFN-44-1EP_9x9mm_P0.65mm_EP7.5x7.5mm_ThermalVias +44-Lead Plastic Quad Flat, No Lead Package - 9x9 mm Body [QFN] with thermal vias; see section 10.3 of https://www.parallax.com/sites/default/files/downloads/P8X32A-Propeller-Datasheet-v1.4.0_0.pdf +QFN 0.65 +0 +55 +45 +Package_DFN_QFN +QFN-48-1EP_5x5mm_P0.35mm_EP3.7x3.7mm +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_5x5mm_P0.35mm_EP3.7x3.7mm_ThermalVias +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.2x4.2mm +QFN, 48 Pin (https://static.dev.sifive.com/SiFive-FE310-G000-datasheet-v1p5.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.2x4.2mm_ThermalVias +QFN, 48 Pin (https://static.dev.sifive.com/SiFive-FE310-G000-datasheet-v1p5.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.3x4.3mm +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.3x4.3mm_ThermalVias +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.6x4.6mm +QFN, 48 Pin (http://infocenter.nordicsemi.com/pdf/nRF51822_PS_v3.3.pdf#page=67), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.6x4.6mm_ThermalVias +QFN, 48 Pin (http://infocenter.nordicsemi.com/pdf/nRF51822_PS_v3.3.pdf#page=67), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.66x4.66mm +QFN, 48 Pin (https://www.onsemi.com/pub/Collateral/485BA.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.66x4.66mm_ThermalVias +QFN, 48 Pin (https://www.onsemi.com/pub/Collateral/485BA.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.3x5.3mm +QFN, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2041_datasheet.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.3x5.3mm_ThermalVias +QFN, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2041_datasheet.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.6x5.6mm +QFN, 48 Pin (http://www.st.com/resource/en/datasheet/stm32f042k6.pdf#page=94), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.6x5.6mm_ThermalVias +QFN, 48 Pin (http://www.st.com/resource/en/datasheet/stm32f042k6.pdf#page=94), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm +QFN, 48 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_48_05-08-1704.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm_ThermalVias +QFN, 48 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_48_05-08-1704.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.45x5.45mm +QFN, 48 Pin (http://www.thatcorp.com/datashts/THAT_626x_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.45x5.45mm_ThermalVias +QFN, 48 Pin (http://www.thatcorp.com/datashts/THAT_626x_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_8x8mm_P0.5mm_EP6.2x6.2mm +QFN, 48 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT232H.pdf#page=49), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +49 +Package_DFN_QFN +QFN-48-1EP_8x8mm_P0.5mm_EP6.2x6.2mm_ThermalVias +QFN, 48 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT232H.pdf#page=49), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +111 +49 +Package_DFN_QFN +QFN-52-1EP_7x8mm_P0.5mm_EP5.41x6.45mm +QFN, 52 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_52_05-08-1729.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +53 +Package_DFN_QFN +QFN-52-1EP_7x8mm_P0.5mm_EP5.41x6.45mm_ThermalVias +QFN, 52 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_52_05-08-1729.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +104 +53 +Package_DFN_QFN +QFN-56-1EP_7x7mm_P0.4mm_EP5.6x5.6mm +QFN, 56 Pin (http://www.cypress.com/file/416486/download#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_7x7mm_P0.4mm_EP5.6x5.6mm_ThermalVias +QFN, 56 Pin (http://www.cypress.com/file/416486/download#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.3x4.3mm +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002142A.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.3x4.3mm_ThermalVias +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002142A.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.5x5.2mm +QFN, 56 Pin (http://www.ti.com/lit/an/scea032/scea032.pdf#page=4), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.5x5.2mm_ThermalVias +QFN, 56 Pin (http://www.ti.com/lit/an/scea032/scea032.pdf#page=4), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.5x5.2mm_ThermalVias_TopTented +QFN, 56 Pin top tented version (manually modified). For information see: http://www.cypress.com/file/138911/download +QFN DFN_QFN +0 +115 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.6x5.6mm +QFN, 56 Pin (http://www.ti.com/lit/ds/symlink/tlc5957.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.6x5.6mm_ThermalVias +QFN, 56 Pin (http://www.ti.com/lit/ds/symlink/tlc5957.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.9x5.9mm +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001734B.pdf#page=50), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.9x5.9mm_ThermalVias +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001734B.pdf#page=50), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-64-1EP_8x8mm_P0.4mm_EP6.5x6.5mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_8x8_with%206_5x6_5%20EP_JXX_C04-0437A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_8x8mm_P0.4mm_EP6.5x6.5mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_8x8_with%206_5x6_5%20EP_JXX_C04-0437A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP3.8x3.8mm +QFN, 64 Pin (https://datasheet.lcsc.com/szlcsc/Realtek-Semicon-RTL8211EG-VB-CG_C69264.pdf#page=77), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP3.8x3.8mm_ThermalVias +QFN, 64 Pin (https://datasheet.lcsc.com/szlcsc/Realtek-Semicon-RTL8211EG-VB-CG_C69264.pdf#page=77), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +79 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.7x4.7mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/60001477A.pdf (page 1083)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.7x4.7mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/60001477A.pdf (page 1083)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.35x4.35mm +QFN, 64 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT2232H.pdf#page=57), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.35x4.35mm_ThermalVias +QFN, 64 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT2232H.pdf#page=57), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.4x5.4mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/70593d.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +81 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.4x5.4mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/70593d.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.45x5.45mm +QFN, 64 Pin (https://www.infineon.com/dgdl/Infineon-MA12040-DS-v01_00-EN.pdf?fileId=5546d46264a8de7e0164b7467a3d617c#page=81), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +81 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.45x5.45mm_ThermalVias +QFN, 64 Pin (https://www.infineon.com/dgdl/Infineon-MA12040-DS-v01_00-EN.pdf?fileId=5546d46264a8de7e0164b7467a3d617c#page=81), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP6x6mm +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/tusb8041.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +81 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP6x6mm_ThermalVias +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/tusb8041.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.3x7.3mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002304A.pdf (page 43)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.3x7.3mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002304A.pdf (page 43)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.5x7.5mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc7593.pdf (page 432)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +101 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.5x7.5mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc7593.pdf (page 432)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +151 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.15x7.15mm +QFN, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/229321fa.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.15x7.15mm_ThermalVias +QFN, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/229321fa.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.25x7.25mm +64-Lead Plastic Quad Flat No-Lead Package, 9x9mm Body (see Atmel Appnote 8826) +QFN 0.5 +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.35x7.35mm +64-Lead Plastic Quad Flat, No Lead Package (MR) - 9x9x0.9 mm Body [QFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN 0.5 +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.65x7.65mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-2549-8-bit-AVR-Microcontroller-ATmega640-1280-1281-2560-2561_datasheet.pdf (page 415)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +101 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.65x7.65mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-2549-8-bit-AVR-Microcontroller-ATmega640-1280-1281-2560-2561_datasheet.pdf (page 415)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +151 +65 +Package_DFN_QFN +QFN-68-1EP_8x8mm_P0.4mm_EP5.2x5.2mm +QFN, 68 Pin (https://cdn.microsemi.com/documents/1bf6886f-5919-4508-a50b-b1dbf3fdf0f4/download/#page=98), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +85 +69 +Package_DFN_QFN +QFN-68-1EP_8x8mm_P0.4mm_EP5.2x5.2mm_ThermalVias +QFN, 68 Pin (https://cdn.microsemi.com/documents/1bf6886f-5919-4508-a50b-b1dbf3fdf0f4/download/#page=98), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +111 +69 +Package_DFN_QFN +QFN-72-1EP_10x10mm_P0.5mm_EP6x6mm +QFN, 72 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001682C.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +82 +73 +Package_DFN_QFN +QFN-72-1EP_10x10mm_P0.5mm_EP6x6mm_ThermalVias +QFN, 72 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001682C.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +135 +73 +Package_DFN_QFN +QFN-76-1EP_9x9mm_P0.4mm_EP3.8x3.8mm +QFN, 76 Pin (https://www.marvell.com/documents/bqcwxsoiqfjkcjdjhkvc/#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +86 +77 +Package_DFN_QFN +QFN-76-1EP_9x9mm_P0.4mm_EP3.8x3.8mm_ThermalVias +QFN, 76 Pin (https://www.marvell.com/documents/bqcwxsoiqfjkcjdjhkvc/#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +103 +77 +Package_DFN_QFN +Qorvo_DFN-8-1EP_2x2mm_P0.5mm +DFN 8 2x2mm, 0.5mm http://www.qorvo.com/products/d/da000896 +DFN 0.5 Qorvo 2x2mm +0 +9 +9 +Package_DFN_QFN +ROHM_DFN0604-3 +DFN package size 0604 3 pins +DFN package size 0604 3 pins +0 +3 +3 +Package_DFN_QFN +ST_UFQFPN-20_3x3mm_P0.5mm +UFQFPN 20-lead, 3 x 3 mm, 0.5 mm pitch, ultra thin fine pitch quad flat package (http://www.st.com/resource/en/datasheet/stm8s003f3.pdf) +UFQFPN 0.5 +0 +20 +20 +Package_DFN_QFN +ST_UQFN-6L_1.5x1.7mm_Pitch0.5mm +ST UQFN 6 pin 0.5mm Pitch http://www.st.com/resource/en/datasheet/ecmf02-2amx6.pdf +UQFN DFN 0.5 ST +0 +6 +6 +Package_DFN_QFN +SiliconLabs_QFN-20-1EP_3x3mm_P0.5mm_EP1.8x1.8mm +20-Lead Plastic Quad Flat, No Lead Package - 3x3 mm Body [QFN] with corner pads; see figure 8.2 of https://www.silabs.com/documents/public/data-sheets/efm8bb1-datasheet.pdf +QFN 0.5 +0 +25 +21 +Package_DFN_QFN +SiliconLabs_QFN-20-1EP_3x3mm_P0.5mm_EP1.8x1.8mm_ThermalVias +20-Lead Plastic Quad Flat, No Lead Package - 3x3 mm Body [QFN] with corner pads and thermal vias; see figure 8.2 of https://www.silabs.com/documents/public/data-sheets/efm8bb1-datasheet.pdf +QFN 0.5 +0 +31 +21 +Package_DFN_QFN +TDFN-6-1EP_2.5x2.5mm_P0.65mm_EP1.3x2mm +TDFN, 6 Pin (http://www.nve.com/Downloads/ab3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +11 +7 +Package_DFN_QFN +TDFN-6-1EP_2.5x2.5mm_P0.65mm_EP1.3x2mm_ThermalVias +TDFN, 6 Pin (http://www.nve.com/Downloads/ab3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +18 +7 +Package_DFN_QFN +TDFN-8-1EP_2x2mm_P0.5mm_EP0.8x1.2mm +TDFN, 8 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0168.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +13 +9 +Package_DFN_QFN +TDFN-8-1EP_3x2mm_P0.5mm_EP1.3x1.4mm +TDFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/MCP6V66-Family-Data-Sheet-DS20006266A.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +13 +9 +Package_DFN_QFN +TDFN-8-1EP_3x2mm_P0.5mm_EP1.80x1.65mm +8-lead plastic dual flat, 2x3x0.75mm size, 0.5mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_TDFN_2x3_MN_C04-0129E-MN.pdf) +TDFN DFN 0.5mm +0 +12 +9 +Package_DFN_QFN +TDFN-8-1EP_3x2mm_P0.5mm_EP1.80x1.65mm_ThermalVias +8-lead plastic dual flat, 2x3x0.75mm size, 0.5mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_TDFN_2x3_MN_C04-0129E-MN.pdf) +TDFN DFN 0.5mm +0 +17 +9 +Package_DFN_QFN +TDFN-10-1EP_2x3mm_P0.5mm_EP0.9x2mm +TDFN, 10 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0429.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +13 +11 +Package_DFN_QFN +TDFN-10-1EP_2x3mm_P0.5mm_EP0.9x2mm_ThermalVias +TDFN, 10 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0429.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +16 +11 +Package_DFN_QFN +TDFN-12_2x3mm_P0.5mm +TDFN, 12 Pads, No exposed, http://www.st.com/resource/en/datasheet/stm6600.pdf +DFN +0 +12 +12 +Package_DFN_QFN +TDFN-14-1EP_3x3mm_P0.4mm_EP1.78x2.35mm +TDFN, 14 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0137.PDF (T1433-2C)), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +19 +15 +Package_DFN_QFN +TDFN-14-1EP_3x3mm_P0.4mm_EP1.78x2.35mm_ThermalVias +TDFN, 14 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0137.PDF (T1433-2C)), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +26 +15 +Package_DFN_QFN +TQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +TQFN, 16 Pin (https://www.diodes.com/assets/Datasheets/PI6C5946002.pdf#page=12), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_3x3mm_P0.5mm_EP1.23x1.23mm +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0136.PDF (T1633-5), https://pdfserv.maximintegrated.com/land_patterns/90-0032.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_3x3mm_P0.5mm_EP1.23x1.23mm_ThermalVias +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0136.PDF (T1633-5), https://pdfserv.maximintegrated.com/land_patterns/90-0032.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +26 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP2.29x2.29mm +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP2.29x2.29mm_ThermalVias +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +26 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP3.1x3.1mm +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-2)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP3.1x3.1mm_ThermalVias +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-2)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +31 +17 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.1x3.1mm +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +25 +21 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.1x3.1mm_ThermalVias +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +35 +21 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.25x3.25mm +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-5)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +25 +21 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.25x3.25mm_ThermalVias +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-5)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +35 +21 +Package_DFN_QFN +TQFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_PullBack +TQFN, 24 Pin (https://ams.com/documents/20143/36005/AS1115_DS000206_1-00.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +29 +25 +Package_DFN_QFN +TQFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_PullBack_ThermalVias +TQFN, 24 Pin (https://ams.com/documents/20143/36005/AS1115_DS000206_1-00.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +39 +25 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP2.7x2.7mm +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +33 +29 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP2.7x2.7mm_ThermalVias +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +38 +29 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP3.25x3.25mm +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +33 +29 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP3.25x3.25mm_ThermalVias +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +43 +29 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP2.1x2.1mm +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-6)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +37 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP2.1x2.1mm_ThermalVias +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-6)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +42 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +37 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +47 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.4x3.4mm +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-9)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +37 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.4x3.4mm_ThermalVias +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-9)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +47 +33 +Package_DFN_QFN +TQFN-40-1EP_5x5mm_P0.4mm_EP3.5x3.5mm +TQFN, 40 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T4055-1)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +45 +41 +Package_DFN_QFN +TQFN-40-1EP_5x5mm_P0.4mm_EP3.5x3.5mm_ThermalVias +TQFN, 40 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T4055-1)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +55 +41 +Package_DFN_QFN +TQFN-48-1EP_7x7mm_P0.5mm_EP5.1x5.1mm +TQFN, 48 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0144.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +58 +49 +Package_DFN_QFN +TQFN-48-1EP_7x7mm_P0.5mm_EP5.1x5.1mm_ThermalVias +TQFN, 48 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0144.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +75 +49 +Package_DFN_QFN +Texas_DRB0008A +DFN-8, 3x3x1mm, http://www.ti.com/lit/ds/symlink/ucc24610.pdf +DRB0008A +0 +23 +9 +Package_DFN_QFN +Texas_MOF0009A +Texas Instruments, QFM MOF0009A, 6x8x2mm (http://www.ti.com/lit/ml/mpsi063a/mpsi063a.pdf) +ti qfm mof0009a +0 +24 +9 +Package_DFN_QFN +Texas_QFN-41_10x16mm +QFN, 41 Pin (http://www.ti.com/lit/ml/mpqf506/mpqf506.pdf) +QFN DFN_QFN +0 +65 +41 +Package_DFN_QFN +Texas_R-PUQFN-N10 +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=MPQF186&fileType=pdf +Texas_R-PUQFN-N10 +0 +10 +10 +Package_DFN_QFN +Texas_R-PWQFN-N28_EP2.1x3.1mm +QFN, 28 Pin (http://www.ti.com/lit/ds/symlink/tps51363.pdf#page=29), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +Texas_R-PWQFN-N28_EP2.1x3.1mm_ThermalVias +QFN, 28 Pin (http://www.ti.com/lit/ds/symlink/tps51363.pdf#page=29), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +Texas_RGE0024C_EP2.1x2.1mm +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/pca9548a.pdf#page=37), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_RGE0024C_EP2.1x2.1mm_ThermalVias +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/pca9548a.pdf#page=37), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_RGE0024H_EP2.7x2.7mm +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_RGE0024H_EP2.7x2.7mm_ThermalVias +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_RGV_S-PVQFN-N16_EP2.1x2.1mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ina3221.pdf#page=44), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +Texas_RGV_S-PVQFN-N16_EP2.1x2.1mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ina3221.pdf#page=44), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_RGY_R-PVQFN-N24_EP2.05x3.1mm +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq24133.pdf#page=40) +QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_RGY_R-PVQFN-N24_EP2.05x3.1mm_ThermalVias +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq24133.pdf#page=40) +QFN NoLead +0 +36 +25 +Package_DFN_QFN +Texas_RNN0018A +Texas Instruments, VQFN-HR RNN0018A (http://www.ti.com/lit/ds/symlink/tps568215.pdf) +ti vqfn-hr rnn0018a +0 +26 +18 +Package_DFN_QFN +Texas_RUM0016A_EP2.6x2.6mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/lmh0074.pdf#page=13), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +Texas_RUM0016A_EP2.6x2.6mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/lmh0074.pdf#page=13), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_RWH0032A +Texas Instruments, RWH0032A, 8x8x0.9mm (http://www.ti.com/lit/ds/snosd10c/snosd10c.pdf) +ti rwh0032a +0 +71 +33 +Package_DFN_QFN +Texas_RWH0032A_ThermalVias +Texas Instruments, RWH0032A, 8x8x0.9mm (http://www.ti.com/lit/ds/snosd10c/snosd10c.pdf) +ti rwh0032a +0 +94 +33 +Package_DFN_QFN +Texas_R_PUQFN-N12 +Texas_R_PUQFN-N12 http://www.ti.com/lit/ds/symlink/txb0104.pdf +Texas_R_PUQFN-N12 +0 +13 +12 +Package_DFN_QFN +Texas_S-PDSO-N10_EP1.2x2mm +DFN, 10 Pin (http://www.ti.com/lit/ds/symlink/tps7a91.pdf#page=30), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +15 +11 +Package_DFN_QFN +Texas_S-PDSO-N10_EP1.2x2mm_ThermalVias +DFN, 10 Pin (http://www.ti.com/lit/ds/symlink/tps7a91.pdf#page=30), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +22 +11 +Package_DFN_QFN +Texas_S-PVQFN-N14 +Texas_S-PVQFN-N14 http://www.ti.com/lit/ds/symlink/txb0104.pdf +Texas_S-PVQFN-N14_4.3x4.3_Pitch0.5mm_ThermalPad +0 +19 +15 +Package_DFN_QFN +Texas_S-PVQFN-N14_ThermalVias +Texas_S-PVQFN-N14_ThermalVias http://www.ti.com/lit/ds/symlink/txb0104.pdf +Texas_S-PVQFN-N14_ThermalVias +0 +24 +15 +Package_DFN_QFN +Texas_S-PVQFN-N16_EP2.7x2.7mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/msp430g2001.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +Texas_S-PVQFN-N16_EP2.7x2.7mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/msp430g2001.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.4x2.4mm +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/cc1101.pdf#page=101), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.4x2.4mm_ThermalVias +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/cc1101.pdf#page=101), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.7x2.7mm +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/drv8662.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.7x2.7mm_ThermalVias +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/drv8662.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP3.15x3.15mm +QFN, 20 Pin (www.ti.com/lit/ds/symlink/tps7a7200.pdf#page=36), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP3.15x3.15mm_ThermalVias +QFN, 20 Pin (www.ti.com/lit/ds/symlink/tps7a7200.pdf#page=36), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +21 +Package_DFN_QFN +Texas_S-PVQFN-N24_EP2.1x2.1mm +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5720.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_S-PVQFN-N24_EP2.1x2.1mm_ThermalVias +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5720.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_S-PVQFN-N32_EP3.45x3.45mm +QFN, 32 Pin (http://www.ti.com/lit/ds/symlink/msp430f1122.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +Texas_S-PVQFN-N32_EP3.45x3.45mm_ThermalVias +QFN, 32 Pin (http://www.ti.com/lit/ds/symlink/msp430f1122.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +Texas_S-PVQFN-N36_EP4.4x4.4mm +QFN, 36 Pin (http://www.ti.com/lit/ds/slvsba5d/slvsba5d.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +Texas_S-PVQFN-N36_EP4.4x4.4mm_ThermalVias +QFN, 36 Pin (http://www.ti.com/lit/ds/slvsba5d/slvsba5d.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +79 +37 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP2.9x2.9mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5731.pdf#page=111 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +45 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP2.9x2.9mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5731.pdf#page=111 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +55 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP3.52x2.62mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/drv8308.pdf#page=56 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP3.52x2.62mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/drv8308.pdf#page=56 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +60 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.6x4.6mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/dac7750.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.6x4.6mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/dac7750.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +83 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.15x4.15mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430g2755.pdf#page=70 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.15x4.15mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430g2755.pdf#page=70 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +83 +41 +Package_DFN_QFN +Texas_S-PVQFN-N48_EP5.15x5.15mm +QFN, 48 Pin (http://www.ti.com/lit/ds/symlink/msp430f5232.pdf#page=111), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +Texas_S-PVQFN-N48_EP5.15x5.15mm_ThermalVias +QFN, 48 Pin (http://www.ti.com/lit/ds/symlink/msp430f5232.pdf#page=111), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +111 +49 +Package_DFN_QFN +Texas_S-PVQFN-N64_EP4.25x4.25mm +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/msp430f5217.pdf#page=120), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +69 +65 +Package_DFN_QFN +Texas_S-PVQFN-N64_EP4.25x4.25mm_ThermalVias +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/msp430f5217.pdf#page=120), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +Texas_S-PWQFN-N16_EP2.1x2.1mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/drv8801.pdf#page=31 MO-220 variation VGGC), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +Texas_S-PWQFN-N16_EP2.1x2.1mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/drv8801.pdf#page=31 MO-220 variation VGGC), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_S-PWQFN-N20 +20-Pin Plastic Quad Flatpack No-Lead Package, Body 3.0x3.0x0.8mm, Texas Instruments (http://www.ti.com/lit/ds/symlink/tps22993.pdf) +QFN 0.4 +0 +24 +20 +Package_DFN_QFN +Texas_S-PWQFN-N24_EP2.7x2.7mm +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq25601.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_S-PWQFN-N24_EP2.7x2.7mm_ThermalVias +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq25601.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_S-PWQFN-N32_EP2.8x2.8mm +QFN, 32 Pin (https://www.ti.com/lit/ds/symlink/bq25703a.pdf#page=90), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +Texas_S-PWQFN-N32_EP2.8x2.8mm_ThermalVias +QFN, 32 Pin (https://www.ti.com/lit/ds/symlink/bq25703a.pdf#page=90), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +33 +Package_DFN_QFN +Texas_S-PWQFN-N100_EP5.5x5.5mm +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/lit/ds/sllse76m/sllse76m.pdf +MultiRow QFN +0 +114 +105 +Package_DFN_QFN +Texas_S-PWQFN-N100_EP5.5x5.5mm_ThermalVias +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/lit/ds/sllse76m/sllse76m.pdf +MultiRow QFN +0 +131 +105 +Package_DFN_QFN +Texas_S-PX2QFN-14 +Texas QFN, 14 Pin (http://www.ti.com/lit/ds/symlink/tlv9004.pdf#page=64), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +14 +14 +Package_DFN_QFN +Texas_VQFN-RHL-20 +http://www.ti.com/lit/ds/symlink/bq51050b.pdf +RHL0020A +0 +33 +21 +Package_DFN_QFN +Texas_VQFN-RHL-20_ThermalVias +http://www.ti.com/lit/ds/symlink/bq51050b.pdf +RHL0020A +0 +41 +21 +Package_DFN_QFN +Texas_VSON-HR-8_1.5x2mm_P0.5mm +Texas VSON-HR, 8 Pin (http://www.ti.com/lit/ds/symlink/tps62823.pdf#page=29), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas VSON-HR NoLead +0 +8 +8 +Package_DFN_QFN +Texas_WQFN-MR-100_3x3-DapStencil +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=mpqf258&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=LPPD235&fileType=pdf +MultiRow QFN +0 +113 +105 +Package_DFN_QFN +Texas_WQFN-MR-100_ThermalVias_3x3-DapStencil +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=mpqf258&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=LPPD235&fileType=pdf +MultiRow QFN +0 +126 +105 +Package_DFN_QFN +Texas_X2QFN-12_1.6x1.6mm_P0.4mm +Texas X2QFN, 12 Pin (http://www.ti.com/lit/ml/mpqf391c/mpqf391c.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas X2QFN NoLead +0 +12 +12 +Package_DFN_QFN +UDFN-4-1EP_1x1mm_P0.65mm_EP0.48x0.48mm +UDFN-4_1x1mm_P0.65mm, http://ww1.microchip.com/downloads/en/DeviceDoc/MIC550x-300mA-Single-Output-LDO-in-Small-Packages-DS20006006A.pdf +UDFN-4_1x1mm_P0.65mm +0 +5 +5 +Package_DFN_QFN +UDFN-9_1.0x3.8mm_P0.5mm +9-pin UDFN package, 1.0x3.8mm, (Ref: https://katalog.we-online.de/pbs/datasheet/824014881.pdf) +UDFN SMD +0 +9 +9 +Package_DFN_QFN +UDFN-10_1.35x2.6mm_P0.5mm +http://www.st.com/content/ccc/resource/technical/document/datasheet/f2/11/8a/ed/40/31/40/56/DM00088292.pdf/files/DM00088292.pdf/jcr:content/translations/en.DM00088292.pdf +UDFN 0.5 uQFN +0 +10 +10 +Package_DFN_QFN +UQFN-10_1.3x1.8mm_P0.4mm +UQFN, 10 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001725D.pdf (Page 9)), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +10 +10 +Package_DFN_QFN +UQFN-10_1.4x1.8mm_P0.4mm +UQFN 10pin, https://www.onsemi.com/pub/Collateral/488AT.PDF +UQFN-10_1.4x1.8mm_P0.4mm +0 +10 +10 +Package_DFN_QFN +UQFN-10_1.6x2.1mm_P0.5mm +UQFN, 10 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001725D.pdf (Page 12)), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +10 +10 +Package_DFN_QFN +UQFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm +16-Lead Ultra Thin Quad Flat, No Lead Package (UC) - 3x3x0.5 mm Body [UQFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN 0.5 +0 +21 +17 +Package_DFN_QFN +UQFN-16-1EP_4x4mm_P0.65mm_EP2.6x2.6mm +UQFN, 16 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/16L_UQFN_4x4x0_5mm_JQ_C04257A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +21 +17 +Package_DFN_QFN +UQFN-16-1EP_4x4mm_P0.65mm_EP2.6x2.6mm_ThermalVias +UQFN, 16 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/16L_UQFN_4x4x0_5mm_JQ_C04257A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +31 +17 +Package_DFN_QFN +UQFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm +16-Lead Ultra Thin Plastic Quad Flat, No Lead Package (JQ) - 4x4x0.5 mm Body [UQFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN 0.65 +0 +21 +17 +Package_DFN_QFN +UQFN-20-1EP_3x3mm_P0.4mm_EP1.85x1.85mm +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=332), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +25 +21 +Package_DFN_QFN +UQFN-20-1EP_3x3mm_P0.4mm_EP1.85x1.85mm_ThermalVias +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=332), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +30 +21 +Package_DFN_QFN +UQFN-20-1EP_4x4mm_P0.5mm_EP2.8x2.8mm +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/40001839B.pdf#page=464), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +25 +21 +Package_DFN_QFN +UQFN-20-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_ThermalVias +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/40001839B.pdf#page=464), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +35 +21 +Package_DFN_QFN +UQFN-28-1EP_4x4mm_P0.4mm_EP2.35x2.35mm +UQFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=338), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +33 +29 +Package_DFN_QFN +UQFN-28-1EP_4x4mm_P0.4mm_EP2.35x2.35mm_ThermalVias +UQFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=338), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +43 +29 +Package_DFN_QFN +UQFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm +UQFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=345), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +50 +41 +Package_DFN_QFN +UQFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm_ThermalVias +UQFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=345), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +67 +41 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.45x4.45mm +UQFN, 48 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=347), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +58 +49 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.45x4.45mm_ThermalVias +UQFN, 48 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=347), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +75 +49 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.62x4.62mm +UQFN, 48 Pin (https://github.com/KiCad/kicad-symbols/pull/1189#issuecomment-449506354), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +53 +49 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.62x4.62mm_ThermalVias +UQFN, 48 Pin (https://github.com/KiCad/kicad-symbols/pull/1189#issuecomment-449506354), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +75 +49 +Package_DFN_QFN +VDFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.7mm +8-Lead Very Thin Dual Flatpack No-Lead (LZ) - 2x3x0.9 mm Body [VDFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +11 +9 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/cdclvp1102.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm_ThermalVias +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/cdclvp1102.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.8x1.8mm +VQFN, 16 Pin (https://www.st.com/resource/en/datasheet/stspin220.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.8x1.8mm_ThermalVias +VQFN, 16 Pin (https://www.st.com/resource/en/datasheet/stspin220.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm +VQFN, 16 Pin (http://www.ti.com/lit/ds/sbos354a/sbos354a.pdf, JEDEC MO-220 variant VEED-6), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm_ThermalVias +VQFN, 16 Pin (http://www.ti.com/lit/ds/sbos354a/sbos354a.pdf, JEDEC MO-220 variant VEED-6), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.68x1.68mm +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/tlv62095.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.68x1.68mm_ThermalVias +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/tlv62095.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.4mm_EP1.7x1.7mm +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/20%20Lead%20VQFN%203x3x0_9mm_1_7EP%20U2B%20C04-21496a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +25 +21 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.4mm_EP1.7x1.7mm_ThermalVias +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/20%20Lead%20VQFN%203x3x0_9mm_1_7EP%20U2B%20C04-21496a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +30 +21 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.45mm_EP1.55x1.55mm +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=264), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +25 +21 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.45mm_EP1.55x1.55mm_ThermalVias +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=264), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +30 +21 +Package_DFN_QFN +VQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm +VQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430f1101a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +34 +25 +Package_DFN_QFN +VQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm_ThermalVias +VQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430f1101a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +39 +25 +Package_DFN_QFN +VQFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm +VQFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-9505-AT42-QTouch-BSW-AT42QT1060_Datasheet.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +33 +29 +Package_DFN_QFN +VQFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm_ThermalVias +VQFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-9505-AT42-QTouch-BSW-AT42QT1060_Datasheet.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +43 +29 +Package_DFN_QFN +VQFN-28-1EP_4x5mm_P0.5mm_EP2.55x3.55mm +VQFN, 28 Pin (http://www.ti.com/lit/ds/symlink/lm5175.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +35 +29 +Package_DFN_QFN +VQFN-28-1EP_4x5mm_P0.5mm_EP2.55x3.55mm_ThermalVias +VQFN, 28 Pin (http://www.ti.com/lit/ds/symlink/lm5175.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +48 +29 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +VQFN, 32 Pin (http://ww1.microchip.com/downloads/en/devicedoc/atmel-9520-at42-qtouch-bsw-at42qt1110_datasheet.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +37 +33 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +VQFN, 32 Pin (http://ww1.microchip.com/downloads/en/devicedoc/atmel-9520-at42-qtouch-bsw-at42qt1110_datasheet.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +47 +33 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.5x3.5mm +VQFN, 32 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT4222H.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +37 +33 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.5x3.5mm_ThermalVias +VQFN, 32 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT4222H.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +47 +33 +Package_DFN_QFN +VQFN-46-1EP_5x6mm_P0.4mm_EP2.8x3.8mm +VQFN, 46 Pin (http://www.ti.com/lit/ds/symlink/lp5036.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +53 +47 +Package_DFN_QFN +VQFN-46-1EP_5x6mm_P0.4mm_EP2.8x3.8mm_ThermalVias +VQFN, 46 Pin (http://www.ti.com/lit/ds/symlink/lp5036.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +66 +47 +Package_DFN_QFN +VQFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm +VQFN, 48 Pin (http://www.ti.com/lit/ds/symlink/cc1312r.pdf#page=48), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +53 +49 +Package_DFN_QFN +VQFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm_ThermalVias +VQFN, 48 Pin (http://www.ti.com/lit/ds/symlink/cc1312r.pdf#page=48), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +79 +49 +Package_DFN_QFN +WDFN-8-1EP_2x2.2mm_P0.5mm_EP0.80x0.54 +https://www.onsemi.com/pub/Collateral/511BN.PDF +WDFN-8 1EP 2.2X2.0 0.5P +0 +9 +9 +Package_DFN_QFN +WDFN-8-1EP_3x2mm_P0.5mm_EP1.3x1.4mm +WDFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_TDFN_2x3_MNY_C04-0129E-MNY.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +13 +9 +Package_DFN_QFN +WDFN-8-1EP_4x3mm_P0.65mm_EP2.4x1.8mm +WDFN, 8 Pin (https://www.onsemi.com/pub/Collateral/509AF.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +13 +9 +Package_DFN_QFN +WDFN-8-1EP_4x3mm_P0.65mm_EP2.4x1.8mm_ThermalVias +WDFN, 8 Pin (https://www.onsemi.com/pub/Collateral/509AF.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +20 +9 +Package_DFN_QFN +WDFN-8_2x2mm_P0.5mm +DFN8 2x2, 0.5P; No exposed pad (http://www.onsemi.com/pub/Collateral/NCP4308-D.PDF) +DFN 0.5 +0 +8 +8 +Package_DFN_QFN +WDFN-12-1EP_3x3mm_P0.45mm_EP1.7x2.5mm +WDFN, 12 Pin (https://www.diodes.com/assets/Datasheets/PAM2306.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +17 +13 +Package_DFN_QFN +WQFN-14-1EP_2.5x2.5mm_P0.5mm_EP1.45x1.45mm +WQFN, 14 Pin (https://www.onsemi.com/pub/Collateral/FUSB302B-D.PDF#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +19 +15 +Package_DFN_QFN +WQFN-14-1EP_2.5x2.5mm_P0.5mm_EP1.45x1.45mm_ThermalVias +WQFN, 14 Pin (https://www.onsemi.com/pub/Collateral/FUSB302B-D.PDF#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +24 +15 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +WQFN, 16 Pin (https://www.ti.com/lit/ds/symlink/tpa6132a2.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +21 +17 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm_ThermalVias +WQFN, 16 Pin (https://www.ti.com/lit/ds/symlink/tpa6132a2.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +26 +17 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm +WQFN, 16 Pin (https://www.onsemi.com/pub/Collateral/FUSB307B-D.PDF#page=56), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +21 +17 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm_ThermalVias +WQFN, 16 Pin (https://www.onsemi.com/pub/Collateral/FUSB307B-D.PDF#page=56), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +26 +17 +Package_DFN_QFN +WQFN-16-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +WQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +21 +17 +Package_DFN_QFN +WQFN-16-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +WQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +31 +17 +Package_DFN_QFN +WQFN-20-1EP_2.5x4.5mm_P0.5mm_EP1x2.9mm +http://www.onsemi.com/pub/Collateral/510CD.PDF +WQFN-20 4.5mm 2.5mm 0.5mm +0 +24 +21 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/lm26480.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +29 +25 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/lm26480.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +39 +25 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/ts3a27518e.pdf#page=33), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +29 +25 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm_ThermalVias +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/ts3a27518e.pdf#page=33), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +39 +25 +Package_DFN_QFN +WQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +QFN, 32-Leads, Body 5x5x0.8mm, Pitch 0.5mm, Thermal Pad 3.1x3.1mm; (see Texas Instruments LM25119 http://www.ti.com/lit/ds/symlink/lm25119.pdf) +WQFN 0.5 +0 +37 +33 +Package_DFN_QFN +WQFN-42-1EP_3.5x9mm_P0.5mm_EP2.05x7.55mm +WQFN, 42 Pin (http://www.ti.com/lit/ds/symlink/ts3l501e.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +57 +43 +Package_DFN_QFN +WQFN-42-1EP_3.5x9mm_P0.5mm_EP2.05x7.55mm_ThermalVias +WQFN, 42 Pin (http://www.ti.com/lit/ds/symlink/ts3l501e.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +82 +43 +Package_DIP +DIP-4_W7.62mm +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_LongPads +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_SMDSocket_SmallPads +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_Socket +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_Socket_LongPads +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +4 +4 +Package_DIP +DIP-4_W8.89mm_SMDSocket_LongPads +4-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +4 +4 +Package_DIP +DIP-4_W10.16mm +4-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +4 +4 +Package_DIP +DIP-4_W10.16mm_LongPads +4-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +4 +4 +Package_DIP +DIP-5-6_W7.62mm +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_LongPads +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_SMDSocket_SmallPads +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_Socket +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_Socket_LongPads +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +5 +5 +Package_DIP +DIP-5-6_W8.89mm_SMDSocket_LongPads +5-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +5 +5 +Package_DIP +DIP-5-6_W10.16mm +5-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +5 +5 +Package_DIP +DIP-5-6_W10.16mm_LongPads +5-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +5 +5 +Package_DIP +DIP-6_W7.62mm +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_LongPads +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_SMDSocket_SmallPads +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_Socket +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_Socket_LongPads +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +6 +6 +Package_DIP +DIP-6_W8.89mm_SMDSocket_LongPads +6-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +6 +6 +Package_DIP +DIP-6_W10.16mm +6-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +6 +6 +Package_DIP +DIP-6_W10.16mm_LongPads +6-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +6 +6 +Package_DIP +DIP-8-16_W7.62mm +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +DIP-8-16_W7.62mm_Socket +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +8 +8 +Package_DIP +DIP-8-16_W7.62mm_Socket_LongPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +8 +8 +Package_DIP +DIP-8-N6_W7.62mm +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), missing pin 6 +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +DIP-8-N7_W7.62mm +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), missing pin 7 +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +DIP-8_W7.62mm +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_LongPads +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_SMDSocket_SmallPads +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_Socket +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_Socket_LongPads +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +8 +8 +Package_DIP +DIP-8_W8.89mm_SMDSocket_LongPads +8-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +8 +8 +Package_DIP +DIP-8_W10.16mm +8-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +8 +8 +Package_DIP +DIP-8_W10.16mm_LongPads +8-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +8 +8 +Package_DIP +DIP-10_W7.62mm +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_LongPads +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_SMDSocket_SmallPads +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_Socket +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_Socket_LongPads +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +10 +10 +Package_DIP +DIP-10_W8.89mm_SMDSocket_LongPads +10-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +10 +10 +Package_DIP +DIP-10_W10.16mm +10-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +10 +10 +Package_DIP +DIP-10_W10.16mm_LongPads +10-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +10 +10 +Package_DIP +DIP-12_W7.62mm +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_LongPads +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_SMDSocket_SmallPads +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_Socket +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_Socket_LongPads +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +12 +12 +Package_DIP +DIP-12_W8.89mm_SMDSocket_LongPads +12-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +12 +12 +Package_DIP +DIP-12_W10.16mm +12-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +12 +12 +Package_DIP +DIP-12_W10.16mm_LongPads +12-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +12 +12 +Package_DIP +DIP-14_W7.62mm +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_LongPads +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_SMDSocket_SmallPads +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_Socket +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_Socket_LongPads +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +14 +14 +Package_DIP +DIP-14_W8.89mm_SMDSocket_LongPads +14-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +14 +14 +Package_DIP +DIP-14_W10.16mm +14-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +14 +14 +Package_DIP +DIP-14_W10.16mm_LongPads +14-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +14 +14 +Package_DIP +DIP-16_W7.62mm +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_LongPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_SMDSocket_SmallPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_Socket +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_Socket_LongPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +16 +16 +Package_DIP +DIP-16_W8.89mm_SMDSocket_LongPads +16-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +16 +16 +Package_DIP +DIP-16_W10.16mm +16-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +16 +16 +Package_DIP +DIP-16_W10.16mm_LongPads +16-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +16 +16 +Package_DIP +DIP-18_W7.62mm +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_LongPads +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_SMDSocket_SmallPads +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_Socket +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_Socket_LongPads +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +18 +18 +Package_DIP +DIP-18_W8.89mm_SMDSocket_LongPads +18-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +18 +18 +Package_DIP +DIP-20_W7.62mm +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_LongPads +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_SMDSocket_SmallPads +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_Socket +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_Socket_LongPads +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +20 +20 +Package_DIP +DIP-20_W8.89mm_SMDSocket_LongPads +20-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +20 +20 +Package_DIP +DIP-22_W7.62mm +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_LongPads +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_SMDSocket_SmallPads +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_Socket +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_Socket_LongPads +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +22 +22 +Package_DIP +DIP-22_W8.89mm_SMDSocket_LongPads +22-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +22 +22 +Package_DIP +DIP-22_W10.16mm +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_LongPads +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_SMDSocket_SmallPads +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil SMDSocket SmallPads +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_Socket +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_Socket_LongPads +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket LongPads +0 +22 +22 +Package_DIP +DIP-22_W11.43mm_SMDSocket_LongPads +22-lead though-hole mounted DIP package, row spacing 11.43 mm (450 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 11.43mm 450mil SMDSocket LongPads +0 +22 +22 +Package_DIP +DIP-24_W7.62mm +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_LongPads +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_SMDSocket_SmallPads +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_Socket +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_Socket_LongPads +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +24 +24 +Package_DIP +DIP-24_W8.89mm_SMDSocket_LongPads +24-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +24 +24 +Package_DIP +DIP-24_W10.16mm +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_LongPads +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_SMDSocket_SmallPads +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil SMDSocket SmallPads +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_Socket +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_Socket_LongPads +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket LongPads +0 +24 +24 +Package_DIP +DIP-24_W11.43mm_SMDSocket_LongPads +24-lead though-hole mounted DIP package, row spacing 11.43 mm (450 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 11.43mm 450mil SMDSocket LongPads +0 +24 +24 +Package_DIP +DIP-24_W15.24mm +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_LongPads +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_SMDSocket_SmallPads +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_Socket +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_Socket_LongPads +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +24 +24 +Package_DIP +DIP-24_W16.51mm_SMDSocket_LongPads +24-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +24 +24 +Package_DIP +DIP-28_W7.62mm +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_LongPads +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_SMDSocket_SmallPads +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_Socket +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_Socket_LongPads +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +28 +28 +Package_DIP +DIP-28_W8.89mm_SMDSocket_LongPads +28-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +28 +28 +Package_DIP +DIP-28_W15.24mm +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_LongPads +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_SMDSocket_SmallPads +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_Socket +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_Socket_LongPads +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +28 +28 +Package_DIP +DIP-28_W16.51mm_SMDSocket_LongPads +28-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +28 +28 +Package_DIP +DIP-32_W7.62mm +32-lead dip package, row spacing 7.62 mm (300 mils) +DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +32 +32 +Package_DIP +DIP-32_W15.24mm +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_LongPads +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_SMDSocket_SmallPads +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_Socket +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_Socket_LongPads +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +32 +32 +Package_DIP +DIP-32_W16.51mm_SMDSocket_LongPads +32-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +32 +32 +Package_DIP +DIP-40_W15.24mm +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_LongPads +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_SMDSocket_SmallPads +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_Socket +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_Socket_LongPads +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +40 +40 +Package_DIP +DIP-40_W16.51mm_SMDSocket_LongPads +40-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +40 +40 +Package_DIP +DIP-40_W25.4mm +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils) +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_LongPads +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil LongPads +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_SMDSocket_SmallPads +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil SMDSocket SmallPads +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_Socket +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_Socket_LongPads +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket LongPads +0 +40 +40 +Package_DIP +DIP-40_W26.67mm_SMDSocket_LongPads +40-lead though-hole mounted DIP package, row spacing 26.67 mm (1050 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 26.669999999999998mm 1050mil SMDSocket LongPads +0 +40 +40 +Package_DIP +DIP-42_W15.24mm +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_LongPads +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_SMDSocket_SmallPads +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_Socket +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_Socket_LongPads +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +42 +42 +Package_DIP +DIP-42_W16.51mm_SMDSocket_LongPads +42-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +42 +42 +Package_DIP +DIP-48_W15.24mm +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_LongPads +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_SMDSocket_SmallPads +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_Socket +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_Socket_LongPads +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +48 +48 +Package_DIP +DIP-48_W16.51mm_SMDSocket_LongPads +48-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +48 +48 +Package_DIP +DIP-64_W15.24mm +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_LongPads +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_SMDSocket_SmallPads +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_Socket +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_Socket_LongPads +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +64 +64 +Package_DIP +DIP-64_W16.51mm_SMDSocket_LongPads +64-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +64 +64 +Package_DIP +DIP-64_W22.86mm +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils) +THT DIP DIL PDIP 2.54mm 22.86mm 900mil +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_LongPads +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), LongPads +THT DIP DIL PDIP 2.54mm 22.86mm 900mil LongPads +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_SMDSocket_SmallPads +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 22.86mm 900mil SMDSocket SmallPads +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_Socket +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), Socket +THT DIP DIL PDIP 2.54mm 22.86mm 900mil Socket +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_Socket_LongPads +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 22.86mm 900mil Socket LongPads +0 +64 +64 +Package_DIP +DIP-64_W24.13mm_SMDSocket_LongPads +64-lead though-hole mounted DIP package, row spacing 24.13 mm (950 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 24.13mm 950mil SMDSocket LongPads +0 +64 +64 +Package_DIP +DIP-64_W25.4mm +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils) +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_LongPads +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil LongPads +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_SMDSocket_SmallPads +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil SMDSocket SmallPads +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_Socket +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_Socket_LongPads +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket LongPads +0 +64 +64 +Package_DIP +DIP-64_W26.67mm_SMDSocket_LongPads +64-lead though-hole mounted DIP package, row spacing 26.67 mm (1050 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 26.669999999999998mm 1050mil SMDSocket LongPads +0 +64 +64 +Package_DIP +Fairchild_LSOP-8 +8-Lead, 300\" Wide, Surface Mount Package (https://www.fairchildsemi.com/package-drawings/ML/MLSOP08A.pdf) +LSOP 2.54mm 300mil +0 +8 +8 +Package_DIP +PowerIntegrations_PDIP-8B +Power Integrations variant of 8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads, see https://www.power.com/sites/default/files/product-docs/lnk520.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +7 +7 +Package_DIP +PowerIntegrations_PDIP-8C +Power Integrations variant of 8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads, see https://ac-dc.power.com/sites/default/files/product-docs/tinyswitch-iii_family_datasheet.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +7 +7 +Package_DIP +PowerIntegrations_SDIP-10C +PowerIntegrations variant of 10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads, see https://www.power.com/sites/default/files/product-docs/tophx_family_datasheet.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +9 +9 +Package_DIP +PowerIntegrations_SMD-8 +PowerIntegrations variant of 8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils), see https://www.power.com/sites/default/files/product-docs/lnk520.pdf +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +PowerIntegrations_SMD-8B +PowerIntegrations variant of 8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils), see https://www.power.com/sites/default/files/product-docs/lnk520.pdf +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +PowerIntegrations_SMD-8C +PowerIntegrations variant of 8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils), see https://ac-dc.power.com/sites/default/files/product-docs/tinyswitch-iii_family_datasheet.pdf +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +PowerIntegrations_eDIP-12B +Power Integrations eDIP-12B, see https://www.power.com/sites/default/files/product-docs/linkswitch-pl_family_datasheet.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +11 +11 +Package_DIP +SMDIP-4_W7.62mm +4-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Package_DIP +SMDIP-4_W9.53mm +4-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +4 +4 +Package_DIP +SMDIP-4_W9.53mm_Clearance8mm +4-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +4 +4 +Package_DIP +SMDIP-4_W11.48mm +4-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +4 +4 +Package_DIP +SMDIP-6_W7.62mm +6-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +6 +6 +Package_DIP +SMDIP-6_W9.53mm +6-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +6 +6 +Package_DIP +SMDIP-6_W9.53mm_Clearance8mm +6-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +6 +6 +Package_DIP +SMDIP-6_W11.48mm +6-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +6 +6 +Package_DIP +SMDIP-8_W7.62mm +8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +SMDIP-8_W9.53mm +8-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +8 +8 +Package_DIP +SMDIP-8_W9.53mm_Clearance8mm +8-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +8 +8 +Package_DIP +SMDIP-8_W11.48mm +8-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +8 +8 +Package_DIP +SMDIP-10_W7.62mm +10-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +10 +10 +Package_DIP +SMDIP-10_W9.53mm +10-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +10 +10 +Package_DIP +SMDIP-10_W9.53mm_Clearance8mm +10-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +10 +10 +Package_DIP +SMDIP-10_W11.48mm +10-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +10 +10 +Package_DIP +SMDIP-12_W7.62mm +12-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +12 +12 +Package_DIP +SMDIP-12_W9.53mm +12-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +12 +12 +Package_DIP +SMDIP-12_W9.53mm_Clearance8mm +12-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +12 +12 +Package_DIP +SMDIP-12_W11.48mm +12-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +12 +12 +Package_DIP +SMDIP-14_W7.62mm +14-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +14 +14 +Package_DIP +SMDIP-14_W9.53mm +14-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +14 +14 +Package_DIP +SMDIP-14_W9.53mm_Clearance8mm +14-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +14 +14 +Package_DIP +SMDIP-14_W11.48mm +14-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +14 +14 +Package_DIP +SMDIP-16_W7.62mm +16-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +16 +16 +Package_DIP +SMDIP-16_W9.53mm +16-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +16 +16 +Package_DIP +SMDIP-16_W9.53mm_Clearance8mm +16-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +16 +16 +Package_DIP +SMDIP-16_W11.48mm +16-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +16 +16 +Package_DIP +SMDIP-18_W7.62mm +18-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +18 +18 +Package_DIP +SMDIP-18_W9.53mm +18-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +18 +18 +Package_DIP +SMDIP-18_W9.53mm_Clearance8mm +18-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +18 +18 +Package_DIP +SMDIP-18_W11.48mm +18-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +18 +18 +Package_DIP +SMDIP-20_W7.62mm +20-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +20 +20 +Package_DIP +SMDIP-20_W9.53mm +20-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +20 +20 +Package_DIP +SMDIP-20_W9.53mm_Clearance8mm +20-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +20 +20 +Package_DIP +SMDIP-20_W11.48mm +20-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +20 +20 +Package_DIP +SMDIP-22_W7.62mm +22-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +22 +22 +Package_DIP +SMDIP-22_W9.53mm +22-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +22 +22 +Package_DIP +SMDIP-22_W9.53mm_Clearance8mm +22-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +22 +22 +Package_DIP +SMDIP-22_W11.48mm +22-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +22 +22 +Package_DIP +SMDIP-24_W7.62mm +24-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +24 +24 +Package_DIP +SMDIP-24_W9.53mm +24-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +24 +24 +Package_DIP +SMDIP-24_W11.48mm +24-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +24 +24 +Package_DIP +SMDIP-24_W15.24mm +24-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +24 +24 +Package_DIP +SMDIP-28_W15.24mm +28-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +28 +28 +Package_DIP +SMDIP-32_W7.62mm +32-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +32 +32 +Package_DIP +SMDIP-32_W9.53mm +32-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +32 +32 +Package_DIP +SMDIP-32_W11.48mm +32-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +32 +32 +Package_DIP +SMDIP-32_W15.24mm +32-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +32 +32 +Package_DIP +SMDIP-40_W15.24mm +40-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +40 +40 +Package_DIP +SMDIP-40_W25.24mm +40-lead surface-mounted (SMD) DIP package, row spacing 25.24 mm (993 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 25.24mm 993mil +0 +40 +40 +Package_DIP +SMDIP-42_W15.24mm +42-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +42 +42 +Package_DIP +SMDIP-48_W15.24mm +48-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +48 +48 +Package_DIP +SMDIP-64_W15.24mm +64-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +64 +64 +Package_DIP +Toshiba_11-7A9 +Toshiba 11-7A9 package, like 6-lead dip package with missing pin 5, row spacing 7.62 mm (300 mils), https://toshiba.semicon-storage.com/info/docget.jsp?did=1421&prodName=TLP3021(S) +Toshiba 11-7A9 DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +5 +5 +Package_DIP +Vishay_HVM-DIP-3_W7.62mm +3-lead though-hole mounted high-volatge DIP package (based on standard DIP-4), row spacing 7.62 mm (300 mils), see https://www.vishay.com/docs/91361/hexdip.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Vishay HVMDIP HEXDIP +0 +4 +3 +Package_DirectFET +DirectFET_L4 +DirectFET L4 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=41 +DirectFET L4 MOSFET Infineon +0 +11 +3 +Package_DirectFET +DirectFET_L6 +DirectFET L6 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=42 +DirectFET L6 MOSFET Infineon +0 +13 +3 +Package_DirectFET +DirectFET_L8 +DirectFET L8 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=43 +DirectFET L8 MOSFET Infineon +0 +15 +3 +Package_DirectFET +DirectFET_LA +DirectFET LA https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=44 +DirectFET LA MOSFET Infineon +0 +15 +3 +Package_DirectFET +DirectFET_M2 +DirectFET M2 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=33 +DirectFET M2 MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_M4 +DirectFET M4 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=34 +DirectFET M4 MOSFET Infineon +0 +9 +3 +Package_DirectFET +DirectFET_MA +DirectFET MA https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=35 +DirectFET MA MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_MB +DirectFET MB https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=36 +DirectFET MB MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_MC +DirectFET MC https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=37 +DirectFET MC MOSFET Infineon +0 +10 +3 +Package_DirectFET +DirectFET_MD +DirectFET MD https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=38 +DirectFET MD MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_ME +DirectFET ME https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=39 +DirectFET ME MOSFET Infineon +0 +10 +3 +Package_DirectFET +DirectFET_MF +DirectFET MF https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=40 +DirectFET MF MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_MN +DirectFET MN https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=30 +DirectFET MN MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MP +DirectFET MP https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=28 +DirectFET MP MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MQ +DirectFET MQ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=29 +DirectFET MQ MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MT +DirectFET MT https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=26 +DirectFET MT MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MU +DirectFET MU https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=32 +DirectFET MU MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MX +DirectFET MX https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=27 +DirectFET MX MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MZ +DirectFET MZ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=31 +DirectFET MZ MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_S1 +DirectFET S1 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=20 +DirectFET S1 MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_S2 +DirectFET S2 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=21 +DirectFET S2 MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_S3C +DirectFET S3C https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=25 +DirectFET S3C MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_SA +DirectFET SA https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=22 +DirectFET SA MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_SB +DirectFET SB https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=23 +DirectFET SB MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_SC +DirectFET SC https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=24 +DirectFET SC MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_SH +DirectFET SH https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=19 +DirectFET SH MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_SJ +DirectFET SJ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=18 +DirectFET SJ MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_SQ +DirectFET SQ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=17 +DirectFET SQ MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_ST +DirectFET ST https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=16 +DirectFET ST MOSFET Infineon +0 +7 +3 +Package_LCC +PLCC-20 +PLCC, 20 pins, surface mount +plcc smt +0 +20 +20 +Package_LCC +PLCC-20_SMD-Socket +PLCC, 20 pins, surface mount +plcc smt +0 +20 +20 +Package_LCC +PLCC-20_THT-Socket +PLCC, 20 pins, through hole +plcc leaded +0 +20 +20 +Package_LCC +PLCC-28 +PLCC, 28 pins, surface mount +plcc smt +0 +28 +28 +Package_LCC +PLCC-28_SMD-Socket +PLCC, 28 pins, surface mount +plcc smt +0 +28 +28 +Package_LCC +PLCC-28_THT-Socket +PLCC, 28 pins, through hole +plcc leaded +0 +28 +28 +Package_LCC +PLCC-32_11.4x14.0mm_P1.27mm +PLCC, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc0015.pdf), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +32 +32 +Package_LCC +PLCC-32_THT-Socket +PLCC, 32 pins, through hole, http://www.assmann-wsw.com/fileadmin/datasheets/ASS_0981_CO.pdf +plcc leaded +0 +32 +32 +Package_LCC +PLCC-44 +PLCC, 44 pins, surface mount +plcc smt +0 +44 +44 +Package_LCC +PLCC-44_16.6x16.6mm_P1.27mm +PLCC, 44 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +44 +44 +Package_LCC +PLCC-44_SMD-Socket +PLCC, 44 pins, surface mount +plcc smt +0 +44 +44 +Package_LCC +PLCC-44_THT-Socket +PLCC, 44 pins, through hole +plcc leaded +0 +44 +44 +Package_LCC +PLCC-52 +PLCC, 52 pins, surface mount +plcc smt +0 +52 +52 +Package_LCC +PLCC-52_SMD-Socket +PLCC, 52 pins, surface mount +plcc smt +0 +52 +52 +Package_LCC +PLCC-52_THT-Socket +PLCC, 52 pins, through hole +plcc leaded +0 +52 +52 +Package_LCC +PLCC-68 +PLCC, 68 pins, surface mount +plcc smt +0 +68 +68 +Package_LCC +PLCC-68_24.2x24.2mm_P1.27mm +PLCC, 68 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +68 +68 +Package_LCC +PLCC-68_SMD-Socket +PLCC, 68 pins, surface mount +plcc smt +0 +68 +68 +Package_LCC +PLCC-68_THT-Socket +PLCC, 68 pins, through hole +plcc leaded +0 +68 +68 +Package_LCC +PLCC-84 +PLCC, 84 pins, surface mount +plcc smt +0 +84 +84 +Package_LCC +PLCC-84_29.3x29.3mm_P1.27mm +PLCC, 84 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +84 +84 +Package_LCC +PLCC-84_SMD-Socket +PLCC, 84 pins, surface mount +plcc smt +0 +84 +84 +Package_LCC +PLCC-84_THT-Socket +PLCC, 84 pins, through hole +plcc leaded +0 +84 +84 +Package_LGA +AMS_LGA-10-1EP_2.7x4mm_P0.6mm +LGA-10, http://ams.com/eng/content/download/951091/2269479/471718 +lga land grid array +0 +13 +11 +Package_LGA +AMS_LGA-20_4.7x4.5mm_P0.65mm +http://ams.com/eng/content/download/1008631/2361759/498838 +AMS LGA +0 +20 +20 +Package_LGA +Bosch_LGA-8_2.5x2.5mm_P0.65mm_ClockwisePinNumbering +LGA-8 +lga land grid array +0 +8 +8 +Package_LGA +Bosch_LGA-8_2x2.5mm_P0.65mm_ClockwisePinNumbering +LGA-8, https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-18.pdf +lga land grid array +0 +8 +8 +Package_LGA +Bosch_LGA-8_3x3mm_P0.8mm_ClockwisePinNumbering +Bosch LGA, 8 Pin (https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BME680-DS001-00.pdf#page=44), generated with kicad-footprint-generator ipc_noLead_generator.py +Bosch LGA NoLead +0 +8 +8 +Package_LGA +Bosch_LGA-14_3x2.5mm_P0.5mm +LGA-14 Bosch https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMI160-DS000-07.pdf +lga land grid array +0 +14 +14 +Package_LGA +LGA-8_3x5mm_P1.25mm +LGA-8 +lga land grid array +0 +8 +8 +Package_LGA +LGA-12_2x2mm_P0.5mm +LGA12 +lga land grid array +0 +12 +12 +Package_LGA +LGA-14_2x2mm_P0.35mm_LayoutBorder3x4y +LGA, 14 Pin (http://www.st.com/resource/en/datasheet/lis2dh.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +14 +14 +Package_LGA +LGA-14_3x2.5mm_P0.5mm_LayoutBorder3x4y +LGA, 14 Pin (http://www.st.com/resource/en/datasheet/lsm6ds3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +14 +14 +Package_LGA +LGA-14_3x5mm_P0.8mm_LayoutBorder1x6y +LGA, 14 Pin (http://www.st.com/resource/en/datasheet/lsm303dlhc.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +14 +14 +Package_LGA +LGA-16_3x3mm_P0.5mm +http://www.memsic.com/userfiles/files/DataSheets/Magnetic-Sensors-Datasheets/MMC5883MA-RevC.pdf +lga land grid array +0 +16 +16 +Package_LGA +LGA-16_3x3mm_P0.5mm_LayoutBorder3x5y +LGA, 16 Pin (http://www.st.com/resource/en/datasheet/lis331hh.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +16 +16 +Package_LGA +LGA-16_4x4mm_P0.65mm_LayoutBorder4x4y +LGA, 16 Pin (http://www.st.com/resource/en/datasheet/l3gd20.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +16 +16 +Package_LGA +LGA-24L_3x3.5mm_P0.43mm +LGA 24L 3x3.5mm Pitch 0.43mm +LGA 24L 3x3.5mm Pitch 0.43mm +0 +24 +24 +Package_LGA +LGA-28_5.2x3.8mm_P0.5mm +LGA 28 5.2x3.8mm Pitch 0.5mm +LGA 28 5.2x3.8mm Pitch 0.5mm +0 +28 +28 +Package_LGA +Linear_LGA-133_15.0x15.0mm_Layout12x12_P1.27mm +Analog Devices (Linear Tech), 133-pin LGA uModule, 15.0x15.0x4.32mm, https://www.analog.com/media/en/technical-documentation/data-sheets/4637fc.pdf +133 pin lga +0 +133 +133 +Package_LGA +NXP_LGA-8_3x5mm_P1.25mm_H1.1mm +NXP LGA, 8 Pin (https://www.nxp.com/docs/en/data-sheet/MPL3115A2.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +NXP LGA NoLead +0 +8 +8 +Package_LGA +NXP_LGA-8_3x5mm_P1.25mm_H1.2mm +NXP LGA, 8 Pin (https://www.nxp.com/docs/en/data-sheet/MPL115A1.pdf#page=15), generated with kicad-footprint-generator ipc_noLead_generator.py +NXP LGA NoLead +0 +8 +8 +Package_LGA +ST_HLGA-10_2.5x2.5mm_P0.6mm_LayoutBorder3x2y +ST HLGA, 10 Pin (https://www.st.com/resource/en/datasheet/lps25hb.pdf#page=46), generated with kicad-footprint-generator ipc_noLead_generator.py +ST HLGA NoLead +0 +10 +10 +Package_LGA +Texas_SIL0008D_MicroSiP-8-1EP_2.8x3mm_P0.65mm_EP1.1x1.9mm +Texas SIL0008D MicroSiP, 8 Pin (http://www.ti.com/lit/ds/symlink/tps82130.pdf#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +12 +9 +Package_LGA +Texas_SIL0008D_MicroSiP-8-1EP_2.8x3mm_P0.65mm_EP1.1x1.9mm_ThermalVias +Texas SIL0008D MicroSiP, 8 Pin (http://www.ti.com/lit/ds/symlink/tps82130.pdf#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +16 +9 +Package_LGA +Texas_SIL0010A_MicroSiP-10-1EP_3.8x3mm_P0.6mm_EP0.7x2.9mm +Texas SIL0010A MicroSiP, 10 Pin (http://www.ti.com/lit/ml/mpds579b/mpds579b.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +14 +11 +Package_LGA +Texas_SIL0010A_MicroSiP-10-1EP_3.8x3mm_P0.6mm_EP0.7x2.9mm_ThermalVias +Texas SIL0010A MicroSiP, 10 Pin (http://www.ti.com/lit/ml/mpds579b/mpds579b.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +18 +11 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP4x4mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00482-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +154 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP4x4mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00482-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +171 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP5x5mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00476-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +161 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP5x5mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00476-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +187 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP6.61x5.615mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00485-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +165 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP6.61x5.615mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00485-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +196 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP7.2x6.35mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00487-01.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +175 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP7.2x6.35mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00487-01.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +218 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP8.93x8.7mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00479-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +194 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP8.93x8.7mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00479-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +259 +145 +Package_QFP +HTQFP-64-1EP_10x10mm_P0.5mm_EP8x8mm +64-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1 mm Body, 2.00 mm Footprint [HTQFP] thermal pad +HTQFP-64 Pitch 0.5 +0 +69 +65 +Package_QFP +HTQFP-64-1EP_10x10mm_P0.5mm_EP8x8mm_Mask4.4x4.4mm_ThermalVias +64-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1 mm Body, 2.00 mm Footprint [HTQFP] thermal pad +HTQFP-64 Pitch 0.5 +0 +135 +65 +Package_QFP +LQFP-32_5x5mm_P0.5mm +LQFP, 32 Pin (https://www.nxp.com/docs/en/package-information/SOT401-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +32 +32 +Package_QFP +LQFP-32_7x7mm_P0.8mm +LQFP, 32 Pin (https://www.nxp.com/docs/en/package-information/SOT358-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +32 +32 +Package_QFP +LQFP-36_7x7mm_P0.65mm +LQFP, 36 Pin (https://www.onsemi.com/pub/Collateral/561AV.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +36 +36 +Package_QFP +LQFP-44_10x10mm_P0.8mm +LQFP, 44 Pin (https://www.nxp.com/files-static/shared/doc/package_info/98ASS23225W.pdf?&fsrch=1), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +44 +44 +Package_QFP +LQFP-48-1EP_7x7mm_P0.5mm_EP3.6x3.6mm +LQFP, 48 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +58 +49 +Package_QFP +LQFP-48-1EP_7x7mm_P0.5mm_EP3.6x3.6mm_ThermalVias +LQFP, 48 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +75 +49 +Package_QFP +LQFP-48_7x7mm_P0.5mm +LQFP, 48 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ltc2358-16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +48 +48 +Package_QFP +LQFP-52-1EP_10x10mm_P0.65mm_EP4.8x4.8mm +LQFP, 52 Pin (https://www.onsemi.com/pub/Collateral/848H-01.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +62 +53 +Package_QFP +LQFP-52-1EP_10x10mm_P0.65mm_EP4.8x4.8mm_ThermalVias +LQFP, 52 Pin (https://www.onsemi.com/pub/Collateral/848H-01.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +95 +53 +Package_QFP +LQFP-52_10x10mm_P0.65mm +LQFP, 52 Pin (https://www.nxp.com/docs/en/package-information/98ARL10526D.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +52 +52 +Package_QFP +LQFP-52_14x14mm_P1mm +LQFP, 52 Pin (http://www.holtek.com/documents/10179/116711/HT1632Cv170.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +52 +52 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP5x5mm +LQFP, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/adv7611.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +90 +65 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP5x5mm_ThermalVias +LQFP, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/adv7611.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +107 +65 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP6.5x6.5mm +LQFP, 64 Pin (https://www.nxp.com/files-static/shared/doc/package_info/98ARH98426A.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +90 +65 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP6.5x6.5mm_ThermalVias +LQFP, 64 Pin (https://www.nxp.com/files-static/shared/doc/package_info/98ARH98426A.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +127 +65 +Package_QFP +LQFP-64_7x7mm_P0.4mm +LQFP, 64 Pin (https://www.nxp.com/docs/en/package-information/SOT414-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +64 +64 +Package_QFP +LQFP-64_10x10mm_P0.5mm +LQFP, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ad7606_7606-6_7606-4.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +64 +64 +Package_QFP +LQFP-64_14x14mm_P0.8mm +LQFP, 64 Pin (https://www.nxp.com/docs/en/package-information/SOT791-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +64 +64 +Package_QFP +LQFP-80_10x10mm_P0.4mm +LQFP, 80 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/q80.10x10.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +80 +80 +Package_QFP +LQFP-80_12x12mm_P0.5mm +LQFP, 80 Pin (https://www.nxp.com/docs/en/package-information/SOT315-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +80 +80 +Package_QFP +LQFP-80_14x14mm_P0.65mm +LQFP, 80 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/AD9852.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +80 +80 +Package_QFP +LQFP-100_14x14mm_P0.5mm +LQFP, 100 Pin (https://www.nxp.com/docs/en/package-information/SOT407-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +100 +100 +Package_QFP +LQFP-128_14x14mm_P0.4mm +LQFP, 128 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/q128.14x14.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +128 +128 +Package_QFP +LQFP-128_14x20mm_P0.5mm +LQFP, 128 Pin (https://www.nxp.com/docs/en/package-information/SOT425-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +128 +128 +Package_QFP +LQFP-144_20x20mm_P0.5mm +LQFP, 144 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=425), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +144 +144 +Package_QFP +LQFP-160_24x24mm_P0.5mm +LQFP, 160 Pin (https://www.nxp.com/docs/en/package-information/SOT435-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +160 +160 +Package_QFP +LQFP-176_20x20mm_P0.4mm +LQFP, 176 Pin (https://www.onsemi.com/pub/Collateral/566DB.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +176 +176 +Package_QFP +LQFP-176_24x24mm_P0.5mm +LQFP, 176 Pin (https://www.st.com/resource/en/datasheet/stm32f207vg.pdf#page=163), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +176 +176 +Package_QFP +LQFP-208_28x28mm_P0.5mm +LQFP, 208 Pin (https://www.nxp.com/docs/en/package-information/SOT459-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +208 +208 +Package_QFP +LQFP-216_24x24mm_P0.4mm +LQFP, 216 Pin (https://www.onsemi.com/pub/Collateral/561BE.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +216 +216 +Package_QFP +MQFP-44_10x10mm_P0.8mm +MQFP, 44 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ad7722.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MQFP QFP +0 +44 +44 +Package_QFP +PQFP-44_10x10mm_P0.8mm +44-Lead Plastic Quad Flatpack - 10x10x2.5mm Body (http://www.onsemi.com/pub/Collateral/122BK.PDF) +PQFP 0.8 +0 +44 +44 +Package_QFP +PQFP-80_14x20mm_P0.8mm +PQFP80 14x20 / QIP80E CASE 122BS (see ON Semiconductor 122BS.PDF) +QFP 0.8 +0 +80 +80 +Package_QFP +PQFP-100_14x20mm_P0.65mm +PQFP, 100 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +100 +100 +Package_QFP +PQFP-112_20x20mm_P0.65mm +PQFP, 112 pins, 20mm sq body, 0.65mm pitch (http://cache.freescale.com/files/shared/doc/package_info/98ASS23330W.pdf, http://www.nxp.com/docs/en/application-note/AN4388.pdf) +PQFP 112 +0 +112 +112 +Package_QFP +PQFP-132_24x24mm_P0.635mm +PQFP, 132 pins, 24mm sq body, 0.635mm pitch (https://www.intel.com/content/dam/www/public/us/en/documents/packaging-databooks/packaging-chapter-02-databook.pdf, http://www.nxp.com/docs/en/application-note/AN4388.pdf) +PQFP 132 +0 +132 +132 +Package_QFP +PQFP-132_24x24mm_P0.635mm_i386 +PQFP, 132 pins, 24mm sq body, 0.635mm pitch, Intel 386EX (https://www.intel.com/content/dam/www/public/us/en/documents/packaging-databooks/packaging-chapter-02-databook.pdf, http://www.nxp.com/docs/en/application-note/AN4388.pdf) +PQFP 132 Intel 386EX +0 +132 +132 +Package_QFP +PQFP-144_28x28mm_P0.65mm +PQFP, 144 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +144 +144 +Package_QFP +PQFP-160_28x28mm_P0.65mm +PQFP, 160 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +160 +160 +Package_QFP +PQFP-208_28x28mm_P0.5mm +PQFP, 208 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +208 +208 +Package_QFP +PQFP-240_32.1x32.1mm_P0.5mm +PQFP, 240 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +240 +240 +Package_QFP +PQFP-256_28x28mm_P0.4mm +PQFP256 28x28 / QFP256J CASE 122BX (see ON Semiconductor 122BX.PDF) +QFP 0.4 +0 +256 +256 +Package_QFP +TQFP-32_7x7mm_P0.8mm +32-Lead Plastic Thin Quad Flatpack (PT) - 7x7x1.0 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +32 +32 +Package_QFP +TQFP-44-1EP_10x10mm_P0.8mm_EP4.5x4.5mm +44-Lead Plastic Thin Quad Flatpack (MW) - 10x10x1.0 mm Body [TQFP] With 4.5x4.5 mm Exposed Pad (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +54 +45 +Package_QFP +TQFP-44_10x10mm_P0.8mm +44-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1.0 mm Body [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +44 +44 +Package_QFP +TQFP-48-1EP_7x7mm_P0.5mm_EP3.5x3.5mm +48-Lead Thin Quad Flatpack (PT) - 7x7x1.0 mm Body [TQFP] With Exposed Pad (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.5 +0 +53 +49 +Package_QFP +TQFP-48-1EP_7x7mm_P0.5mm_EP5x5mm +TQFP, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf (page 45)), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +65 +49 +Package_QFP +TQFP-48-1EP_7x7mm_P0.5mm_EP5x5mm_ThermalVias +TQFP, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf (page 45)), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +91 +49 +Package_QFP +TQFP-48_7x7mm_P0.5mm +48 LEAD TQFP 7x7mm (see MICREL TQFP7x7-48LD-PL-1.pdf) +QFP 0.5 +0 +48 +48 +Package_QFP +TQFP-52-1EP_10x10mm_P0.65mm_EP6.5x6.5mm +TQFP, 52 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_52_1.pdf), generated with kicad-footprint-generator ipc_qfp_generator.py +TQFP QFP +0 +78 +53 +Package_QFP +TQFP-52-1EP_10x10mm_P0.65mm_EP6.5x6.5mm_ThermalVias +TQFP, 52 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_52_1.pdf), generated with kicad-footprint-generator ipc_qfp_generator.py +TQFP QFP +0 +79 +53 +Package_QFP +TQFP-64-1EP_10x10mm_P0.5mm_EP8x8mm +64-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1 mm Body, 2.00 mm Footprint [TQFP] thermal pad +QFP 0.5 +0 +90 +65 +Package_QFP +TQFP-64_7x7mm_P0.4mm +TQFP64 7x7, 0.4P CASE 932BH (see ON Semiconductor 932BH.PDF) +QFP 0.4 +0 +64 +64 +Package_QFP +TQFP-64_10x10mm_P0.5mm +TQFP, 64 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +64 +64 +Package_QFP +TQFP-64_14x14mm_P0.8mm +64-Lead Plastic Thin Quad Flatpack (PF) - 14x14x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +64 +64 +Package_QFP +TQFP-80-1EP_14x14mm_P0.65mm_EP9.5x9.5mm +80-Lead Plastic Thin Quad Flatpack (PF) - 14x14mm body, 9.5mm sq thermal pad (http://www.analog.com/media/en/technical-documentation/data-sheets/AD9852.pdf) +QFP 0.65 +0 +85 +81 +Package_QFP +TQFP-80_12x12mm_P0.5mm +80-Lead Plastic Thin Quad Flatpack (PT) - 12x12x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.5 +0 +80 +80 +Package_QFP +TQFP-80_14x14mm_P0.65mm +80-Lead Plastic Thin Quad Flatpack (PF) - 14x14x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.65 +0 +80 +80 +Package_QFP +TQFP-100-1EP_14x14mm_P0.5mm_EP5x5mm +TQFP, 100 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_100_4.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +117 +101 +Package_QFP +TQFP-100-1EP_14x14mm_P0.5mm_EP5x5mm_ThermalVias +TQFP, 100 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_100_4.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +143 +101 +Package_QFP +TQFP-100_12x12mm_P0.4mm +100-Lead Plastic Thin Quad Flatpack (PT) - 12x12x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.4 +0 +100 +100 +Package_QFP +TQFP-100_14x14mm_P0.5mm +TQFP, 100 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +100 +100 +Package_QFP +TQFP-120_14x14mm_P0.4mm +TQFP120 14x14 / TQFP120 CASE 932AZ (see ON Semiconductor 932AZ.PDF) +QFP 0.4 +0 +120 +120 +Package_QFP +TQFP-128_14x14mm_P0.4mm +TQFP128 14x14 / TQFP128 CASE 932BB (see ON Semiconductor 932BB.PDF) +QFP 0.4 +0 +128 +128 +Package_QFP +TQFP-144_16x16mm_P0.4mm +144-Lead Plastic Thin Quad Flatpack (PH) - 16x16x1 mm Body, 2.00 mm Footprint [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.4 +0 +144 +144 +Package_QFP +TQFP-144_20x20mm_P0.5mm +TQFP, 144 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +144 +144 +Package_QFP +TQFP-176_24x24mm_P0.5mm +TQFP, 176 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +176 +176 +Package_QFP +VQFP-80_14x14mm_P0.65mm +VQFP, 80 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +80 +80 +Package_QFP +VQFP-100_14x14mm_P0.5mm +VQFP, 100 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +100 +100 +Package_QFP +VQFP-128_14x14mm_P0.4mm +VQFP, 128 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +128 +128 +Package_QFP +VQFP-176_20x20mm_P0.4mm +VQFP, 176 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +176 +176 +Package_SIP +PowerIntegrations_eSIP-7C +eSIP-7C Vertical Flat Package with Heatsink Tab, https://ac-dc.power.com/sites/default/files/product-docs/topswitch-jx_family_datasheet.pdf +Power Integrations E Package +0 +6 +6 +Package_SIP +PowerIntegrations_eSIP-7F +eSIP-7F Flat Package with Heatsink Tab https://ac-dc.power.com/sites/default/files/product-docs/linkswitch-ph_family_datasheet.pdf +Power Integrations L Package +0 +6 +6 +Package_SIP +SIP-8_19x3mm_P2.54mm +SIP 8-pin (http://www.njr.com/semicon/PDF/package/SIP8_E.pdf) +SIP8 +0 +8 +8 +Package_SIP +SIP-9_21.54x3mm_P2.54mm +SIP 9-pin () +SIP8 +0 +9 +9 +Package_SIP +SIP-9_22.3x3mm_P2.54mm +SIP 9-pin () +SIP8 +0 +9 +9 +Package_SIP +SIP3_11.6x8.5mm +RECOM,R78EXX,https://www.recom-power.com/pdf/Innoline/R-78Exx-0.5.pdf +SIP3 Regulator Module +0 +3 +3 +Package_SIP +SIP4_Sharp-SSR_P7.62mm_Angled +SIP4 Footprint for SSR made by Sharp +Solid State relais SSR Sharp +0 +4 +4 +Package_SIP +SIP4_Sharp-SSR_P7.62mm_Angled_NoHole +SIP4 Footprint for SSR made by Sharp +Solid State relais SSR Sharp +0 +4 +4 +Package_SIP +SIP4_Sharp-SSR_P7.62mm_Straight +SIP4 Footprint for SSR made by Sharp +Solid State relais SSR Sharp +0 +4 +4 +Package_SIP +SIP9_Housing +SIP9 +SIP9 +0 +9 +9 +Package_SIP +SIP9_Housing_BigPads +SIP9, large pads +SIP9 +0 +9 +9 +Package_SIP +SLA704XM +SIP SLA704XM (http://www.sumzi.com/upload/files/2007/07/2007073114282034189.PDF) +SIP +0 +18 +18 +Package_SIP +STK672-040-E +SIP-22 (http://www.onsemi.com/pub_link/Collateral/EN5227-D.PDF) +SIP-22 +0 +22 +22 +Package_SIP +STK672-080-E +SIP-15 (http://www.onsemi.com/pub_link/Collateral/EN6507-D.PDF) +SIP-15 +0 +15 +15 +Package_SIP +Sanyo_STK4xx-15_59.2x8.0mm_P2.54mm +Sanyo SIP-15, 59.2mm x 8.0mm bosy size, STK-433E STK-435E STK-436E (http://datasheet.octopart.com/STK430-Sanyo-datasheet-107060.pdf) +Sanyo SIP-15 +0 +15 +15 +Package_SIP +Sanyo_STK4xx-15_78.0x8.0mm_P2.54mm +Sanyo SIP-15, 78.0mm x 8.0mm bosy size, STK-437E STK-439E STK-441E STK-443E (http://datasheet.octopart.com/STK430-Sanyo-datasheet-107060.pdf) +Sanyo SIP-15 +0 +15 +15 +Package_SO +Diodes_PSOP-8 +8-Lead Plastic PSOP, Exposed Die Pad (see https://www.diodes.com/assets/Datasheets/AP2204.pdf) +SSOP 0.50 exposed pad +0 +12 +9 +Package_SO +Diodes_SO-8EP +8-Lead Plastic SO, Exposed Die Pad (see https://www.diodes.com/assets/Package-Files/SO-8EP.pdf) +SO exposed pad +0 +9 +9 +Package_SO +ETSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3x4.2mm +20-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body with Exposed Pad [eTSSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.65 +0 +27 +21 +Package_SO +HSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.1mm +HSOP, 8 Pin (https://www.st.com/resource/en/datasheet/l5973d.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOP SO +0 +13 +9 +Package_SO +HSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.1mm_ThermalVias +HSOP, 8 Pin (https://www.st.com/resource/en/datasheet/l5973d.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOP SO +0 +20 +9 +Package_SO +HSOP-20-1EP_11.0x15.9mm_P1.27mm_SlugDown +HSOP 11.0x15.9mm Pitch 1.27mm Slug Down (PowerSO-20) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/tda7266d.pdf, www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 1.27mm +0 +23 +21 +Package_SO +HSOP-20-1EP_11.0x15.9mm_P1.27mm_SlugDown_ThermalVias +HSOP 11.0x15.9mm Pitch 1.27mm Slug Down Thermal Vias (PowerSO-20) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/tda7266d.pdf, www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 1.27mm +0 +45 +21 +Package_SO +HSOP-20-1EP_11.0x15.9mm_P1.27mm_SlugUp +HSOP 11.0x15.9mm Pitch 1.27mm Slug Up (PowerSO-20) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/tda7266d.pdf, www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 1.27mm +0 +20 +20 +Package_SO +HSOP-36-1EP_11.0x15.9mm_P0.65mm_SlugDown +HSOP 11.0x15.9mm Pitch 0.65mm Slug Down (PowerSO-36) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/vn808cm-32-e.pdf, http://www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 0.65mm +0 +39 +37 +Package_SO +HSOP-36-1EP_11.0x15.9mm_P0.65mm_SlugDown_ThermalVias +HSOP 11.0x15.9mm Pitch 0.65mm Slug Down Thermal Vias (PowerSO-36) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/vn808cm-32-e.pdf, http://www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 0.65mm +0 +61 +37 +Package_SO +HSOP-36-1EP_11.0x15.9mm_P0.65mm_SlugUp +HSOP 11.0x15.9mm Pitch 0.65mm Slug Up (PowerSO-36) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/vn808cm-32-e.pdf, http://www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 0.65mm +0 +36 +36 +Package_SO +HTSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.4x3.2mm +HTSOP, 8 Pin (https://media.digikey.com/pdf/Data%20Sheets/Rohm%20PDFs/BD9G341EFJ.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSOP SO +0 +13 +9 +Package_SO +HTSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.4x3.2mm_ThermalVias +HTSOP, 8 Pin (https://media.digikey.com/pdf/Data%20Sheets/Rohm%20PDFs/BD9G341EFJ.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSOP SO +0 +20 +9 +Package_SO +HTSSOP-14-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask3x3.1mm +HTSSOP, 14 Pin (http://www.ti.com/lit/ds/symlink/lm5161.pdf#page=34), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +20 +15 +Package_SO +HTSSOP-14-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask3x3.1mm_ThermalVias +HTSSOP, 14 Pin (http://www.ti.com/lit/ds/symlink/lm5161.pdf#page=34), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +36 +15 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm +16-Lead Plastic HTSSOP (4.4x5x1.2mm); Thermal pad; (http://www.ti.com/lit/ds/symlink/drv8833.pdf) +SSOP 0.65 +0 +29 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask2.46x2.31mm +HTSSOP, 16 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +20 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask2.46x2.31mm_ThermalVias +HTSSOP, 16 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +27 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask3x3mm_ThermalVias +16-Lead Plastic HTSSOP (4.4x5x1.2mm); Thermal pad with vias; (http://www.ti.com/lit/ds/symlink/drv8800.pdf) +SSOP 0.65 +0 +46 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3x3mm +HTSSOP, 16 Pin (https://www.st.com/resource/en/datasheet/stp08cp05.pdf#page=20), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +21 +17 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP2.85x4mm +HTSSOP, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0108.PDF U20E-1), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +23 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm +20-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body [HTSSOP], with thermal pad with vias +HTSSOP 0.65 +0 +29 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.4x3.7mm +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/bq24006.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +24 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.75x3.43mm +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=37&zoom=160,-90,3), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +26 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.75x3.43mm_ThermalVias +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=37&zoom=160,-90,3), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +42 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.75x3.43mm_ThermalVias_HandSolder +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=37&zoom=160,-90,3), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +42 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.96x2.96mm +HTSSOP, 20 Pin (https://www.ti.com/lit/ds/symlink/tps2663.pdf#page=49), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +23 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.96x2.96mm_ThermalVias +HTSSOP, 20 Pin (https://www.ti.com/lit/ds/symlink/tps2663.pdf#page=49), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +42 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_ThermalVias +20-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body [HTSSOP], with thermal pad with vias +HTSSOP 0.65 +0 +45 +21 +Package_SO +HTSSOP-24-1EP_4.4x7.8mm_P0.65mm_EP3.2x5mm +HTSSOP, 24 Pin (https://www.st.com/resource/en/datasheet/stp16cp05.pdf#page=25), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +31 +25 +Package_SO +HTSSOP-24-1EP_4.4x7.8mm_P0.65mm_EP3.4x7.8mm_Mask2.4x4.68mm +HTSSOP, 24 Pin (http://www.ti.com/lit/ds/symlink/tps703.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +28 +25 +Package_SO +HTSSOP-24-1EP_4.4x7.8mm_P0.65mm_EP3.4x7.8mm_Mask2.4x4.68mm_ThermalVias +HTSSOP, 24 Pin (http://www.ti.com/lit/ds/symlink/tps703.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +47 +25 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP2.85x5.4mm +HTSSOP, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0108.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +30 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP2.85x5.4mm_ThermalVias +HTSSOP, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0108.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +41 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +39 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm_Mask2.4x6.17mm +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +40 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm_Mask2.4x6.17mm_ThermalVias +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +55 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm_ThermalVias +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +58 +29 +Package_SO +HTSSOP-32-1EP_6.1x11mm_P0.65mm_EP5.2x11mm_Mask4.11x4.36mm +HTSSOP32: plastic thin shrink small outline package; 32 leads; body width 6.1 mm; lead pitch 0.65 mm (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot487-1_po.pdf) +SSOP 0.65 PowerPAD +0 +43 +33 +Package_SO +HTSSOP-32-1EP_6.1x11mm_P0.65mm_EP5.2x11mm_Mask4.11x4.36mm_ThermalVias +HTSSOP32: plastic thin shrink small outline package; 32 leads; body width 6.1 mm; lead pitch 0.65 mm (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot487-1_po.pdf) +SSOP 0.65 PowerPAD +0 +83 +33 +Package_SO +HTSSOP-38-1EP_6.1x12.5mm_P0.65mm_EP5.2x12.5mm_Mask3.39x6.35mm +HTSSOP, 38 Pin (http://www.ti.com/lit/ds/symlink/tlc5951.pdf#page=47&zoom=140,-67,15), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +46 +39 +Package_SO +HTSSOP-38-1EP_6.1x12.5mm_P0.65mm_EP5.2x12.5mm_Mask3.39x6.35mm_ThermalVias +HTSSOP, 38 Pin (http://www.ti.com/lit/ds/symlink/tlc5951.pdf#page=47&zoom=140,-67,15), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +87 +39 +Package_SO +HTSSOP-56-1EP_6.1x14mm_P0.5mm_EP3.61x6.35mm +HTSSOP56: plastic thin shrink small outline package http://www.ti.com/lit/ds/symlink/drv8301.pdf +HTSSOP 0.5 +0 +72 +57 +Package_SO +Infineon_PG-DSO-8-27_3.9x4.9mm_EP2.65x3mm +Infineon PG-DSO, 8 Pin (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-8-27), generated with kicad-footprint-generator ipc_gullwing_generator.py +Infineon PG-DSO SO +0 +13 +9 +Package_SO +Infineon_PG-DSO-8-27_3.9x4.9mm_EP2.65x3mm_ThermalVias +Infineon PG-DSO, 8 Pin (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-8-27), generated with kicad-footprint-generator ipc_gullwing_generator.py +Infineon PG-DSO SO +0 +23 +9 +Package_SO +Infineon_PG-DSO-8-43 +Infineon_PG-DSO-8-43 +DSO DSO-8 SOIC SOIC-8 +0 +12 +9 +Package_SO +Infineon_PG-DSO-12-9 +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-9/) +PG-DSO +0 +23 +13 +Package_SO +Infineon_PG-DSO-12-9_ThermalVias +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-9/) +PG-DSO +0 +42 +13 +Package_SO +Infineon_PG-DSO-12-11 +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-11/) +PG-DSO +0 +23 +13 +Package_SO +Infineon_PG-DSO-12-11_ThermalVias +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-11/) +PG-DSO +0 +42 +13 +Package_SO +Infineon_PG-DSO-20-30 +Infineon SO package 20pin, exposed pad 4.5x7mm (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-71/) +DSO-20 +0 +31 +21 +Package_SO +Infineon_PG-DSO-20-30_ThermalVias +Infineon SO package 20pin, exposed pad 4.5x7mm (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-71/) +DSO-20 +0 +45 +21 +Package_SO +Infineon_PG-DSO-20-32 +Infineon SO package 20pin without exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-32/) +DSO-20 +0 +20 +20 +Package_SO +Infineon_PG-DSO-20-85 +Infineon SO package 20pin with exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-85/) +DSO-20 +0 +31 +21 +Package_SO +Infineon_PG-DSO-20-85_ThermalVias +Infineon SO package 20pin with exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-85/) +DSO-20 +0 +113 +21 +Package_SO +Infineon_PG-DSO-20-87 +Infineon SO package 20pin without exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-87/) +DSO-20 +0 +20 +20 +Package_SO +Infineon_PG-TSDSO-14-22 +Infineon_PG-TSDSO-14-22 +Infineon TSDSO 14-22 +0 +17 +15 +Package_SO +Linear_MSOP-12-16-1EP_3x4mm_P0.5mm +12-Lead Plastic Micro Small Outline Package (MS) [MSOP], variant of MSOP-16 (see http://cds.linear.com/docs/en/datasheet/3630fd.pdf) +SSOP 0.5 +0 +15 +13 +Package_SO +Linear_MSOP-12-16_3x4mm_P0.5mm +12-Lead Plastic Micro Small Outline Package (MS) [MSOP], variant of MSOP-16 (see https://www.analog.com/media/en/technical-documentation/data-sheets/3748fb.pdf) +SSOP 0.5 +0 +12 +12 +Package_SO +MFSOP6-4_4.4x3.6mm_P1.27mm +https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.4pin%20MFSOP6.html +MFSOP 4 pin SMD +0 +4 +4 +Package_SO +MFSOP6-5_4.4x3.6mm_P1.27mm +https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.5pin%20MFSOP6.html +MFSOP 4 pin SMD +0 +5 +5 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.68x1.88mm +MSOP, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4440fb.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +13 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.68x1.88mm_ThermalVias +MSOP, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4440fb.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +18 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.73x1.85mm +MSOP, 8 Pin (http://www.ti.com/lit/ds/symlink/lm25085.pdf#page=32), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +13 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.73x1.85mm_ThermalVias +MSOP, 8 Pin (http://www.ti.com/lit/ds/symlink/lm25085.pdf#page=32), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +18 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.95x2.15mm +MSOP, 8 Pin (http://www.st.com/resource/en/datasheet/pm8834.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +13 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.95x2.15mm_ThermalVias +MSOP, 8 Pin (http://www.st.com/resource/en/datasheet/pm8834.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +18 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP2.5x3mm_Mask1.73x2.36mm +MSOP, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf#page=15), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +14 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP2.5x3mm_Mask1.73x2.36mm_ThermalVias +MSOP, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf#page=15), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +19 +9 +Package_SO +MSOP-8_3x3mm_P0.65mm +MSOP, 8 Pin (https://www.jedec.org/system/files/docs/mo-187F.pdf variant AA), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +8 +8 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.68x1.88mm +MSOP, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3805fg.pdf#page=18), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +15 +11 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.68x1.88mm_ThermalVias +MSOP, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3805fg.pdf#page=18), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +20 +11 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.73x1.98mm +MSOP, 10 Pin (www.allegromicro.com/~/media/Files/Datasheets/A4952-3-Datasheet.ashx?la=en#page=10), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +15 +11 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.73x1.98mm_ThermalVias +MSOP, 10 Pin (www.allegromicro.com/~/media/Files/Datasheets/A4952-3-Datasheet.ashx?la=en#page=10), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +20 +11 +Package_SO +MSOP-10_3x3mm_P0.5mm +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +10 +10 +Package_SO +MSOP-12-1EP_3x4mm_P0.65mm_EP1.65x2.85mm +MSOP, 12 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3652fe.pdf#page=24), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +17 +13 +Package_SO +MSOP-12-1EP_3x4mm_P0.65mm_EP1.65x2.85mm_ThermalVias +MSOP, 12 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3652fe.pdf#page=24), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +24 +13 +Package_SO +MSOP-12-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +19 +13 +Package_SO +MSOP-12-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm_ThermalVias +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +25 +13 +Package_SO +MSOP-12-16_3x4mm_P0.5mm +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +12 +12 +Package_SO +MSOP-12_3x4mm_P0.65mm +MSOP, 12 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/6957fb.pdf#page=36), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +12 +12 +Package_SO +MSOP-16-1EP_3x4.039mm_P0.5mm_EP1.651x2.845mm +MSOP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-msop/05081667_F_MSE16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +21 +17 +Package_SO +MSOP-16-1EP_3x4.039mm_P0.5mm_EP1.651x2.845mm_ThermalVias +MSOP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-msop/05081667_F_MSE16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +28 +17 +Package_SO +MSOP-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm +MSOP, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +21 +17 +Package_SO +MSOP-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm_ThermalVias +MSOP, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +28 +17 +Package_SO +MSOP-16_3x4.039mm_P0.5mm +MSOP, 16 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-msop/05081669_A_MS16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +16 +16 +Package_SO +MSOP-16_3x4mm_P0.5mm +MSOP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/436412f.pdf#page=22), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +16 +16 +Package_SO +ONSemi_SO-8FL_488AA +ON Semi DFN5 5x6mm 1.27P SO-8FL CASE 488A https://www.onsemi.com/pub/Collateral/488AA.PDF +ON Semi DFN5 5x6mm 1.27P SO-8FL CASE 488A +0 +5 +5 +Package_SO +OnSemi_Micro8 +ON Semiconductor Micro8 (Case846A-02): https://www.onsemi.com/pub/Collateral/846A-02.PDF +micro8 +0 +8 +8 +Package_SO +PSOP-44_16.9x27.17mm_P1.27mm +PSOP44: plastic thin shrink small outline package; 44 leads; body width 16.90 mm +PSOP 1.27 +0 +44 +44 +Package_SO +PowerIntegrations_SO-8 +Power-Integrations variant of 8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], see https://ac-dc.power.com/sites/default/files/product-docs/senzero_family_datasheet.pdf +SOIC 1.27 +0 +8 +8 +Package_SO +PowerIntegrations_SO-8B +Power-Integrations variant of 8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], see https://www.mouser.com/ds/2/328/linkswitch-pl_family_datasheet-12517.pdf +SOIC 1.27 +0 +7 +7 +Package_SO +PowerIntegrations_SO-8C +Power-Integrations variant of 8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], see https://www.mouser.com/ds/2/328/linkswitch-pl_family_datasheet-12517.pdf +SOIC 1.27 +0 +7 +7 +Package_SO +PowerIntegrations_eSOP-12B +eSOP-12B SMT Flat Package with Heatsink Tab, see https://ac-dc.power.com/sites/default/files/product-docs/topswitch-jx_family_datasheet.pdf +Power Integrations K Package +0 +12 +12 +Package_SO +PowerPAK_SO-8_Dual +PowerPAK SO-8 Dual (https://www.vishay.com/docs/71655/powerpak.pdf, https://www.vishay.com/docs/72600/72600.pdf) +PowerPAK SO-8 Dual +0 +10 +6 +Package_SO +PowerPAK_SO-8_Single +PowerPAK SO-8 Single (https://www.vishay.com/docs/71655/powerpak.pdf, https://www.vishay.com/docs/72599/72599.pdf) +PowerPAK SO-8 Single +0 +9 +5 +Package_SO +QSOP-16_3.9x4.9mm_P0.635mm +16-Lead Plastic Shrink Small Outline Narrow Body (QR)-.150" Body [QSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.635 +0 +16 +16 +Package_SO +QSOP-20_3.9x8.7mm_P0.635mm +20-Lead Plastic Shrink Small Outline Narrow Body (http://www.analog.com/media/en/technical-documentation/data-sheets/ADuM7640_7641_7642_7643.pdf) +QSOP 0.635 +0 +20 +20 +Package_SO +QSOP-24_3.9x8.7mm_P0.635mm +24-Lead Plastic Shrink Small Outline Narrow Body (QR)-.150" Body [QSOP] (see Microchip Packaging Specification 00000049CH.pdf) +QSOP 0.635 +0 +24 +24 +Package_SO +SC-74-6_1.5x2.9mm_P0.95mm +SC-74, 6 Pin (https://www.nxp.com/docs/en/package-information/SOT457.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SC-74 SO +0 +6 +6 +Package_SO +SO-4_4.4x2.3mm_P1.27mm +4-Lead Plastic Small Outline (SO), see http://datasheet.octopart.com/OPIA403BTRE-Optek-datasheet-5328560.pdf +SO SOIC 1.27 +0 +4 +4 +Package_SO +SO-4_4.4x3.6mm_P2.54mm +4-Lead Plastic Small Outline (SO), see https://www.elpro.org/de/index.php?controller=attachment&id_attachment=339 +SO SOIC 2.54 +0 +4 +4 +Package_SO +SO-4_4.4x3.9mm_P2.54mm +SO, 4 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=10047&prodName=TLP3123), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +4 +4 +Package_SO +SO-4_4.4x4.3mm_P2.54mm +4-Lead Plastic Small Outline (SO), see https://docs.broadcom.com/docs/AV02-0173EN +SO SOIC 2.54 +0 +4 +4 +Package_SO +SO-4_7.6x3.6mm_P2.54mm +4-Lead Plastic Small Outline (SO) (http://www.everlight.com/file/ProductFile/201407061745083848.pdf) +SO SOIC 2.54 +0 +4 +4 +Package_SO +SO-5_4.4x3.6mm_P1.27mm +5-Lead Plastic Small Outline (SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SO SOIC 1.27 +0 +5 +5 +Package_SO +SO-6L_10x3.84mm_P1.27mm +6-pin plasic small outline 7,5mm long https://toshiba.semicon-storage.com/info/docget.jsp?did=53548&prodName=TLP2770 +SO-6L +0 +6 +6 +Package_SO +SO-6_4.4x3.6mm_P1.27mm +6-Lead Plastic Small Outline (SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SO SOIC 1.27 +0 +6 +6 +Package_SO +SO-8_3.9x4.9mm_P1.27mm +SO, 8 Pin (https://www.nxp.com/docs/en/data-sheet/PCF8523.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +8 +8 +Package_SO +SO-8_5.3x6.2mm_P1.27mm +SO, 8 Pin (https://www.ti.com/lit/ml/msop001a/msop001a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +8 +8 +Package_SO +SO-14_3.9x8.65mm_P1.27mm +SO, 14 Pin (https://www.st.com/resource/en/datasheet/l6491.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +14 +14 +Package_SO +SO-14_5.3x10.2mm_P1.27mm +SO, 14 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +14 +14 +Package_SO +SO-16_3.9x9.9mm_P1.27mm +SO, 16 Pin (https://www.nxp.com/docs/en/package-information/SOT109-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +16 +16 +Package_SO +SO-16_5.3x10.2mm_P1.27mm +SO, 16 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +16 +16 +Package_SO +SO-20-1EP_7.52x12.825mm_P1.27mm_EP6.045x12.09mm_Mask3.56x4.47mm +SO, 20 Pin (http://www.ti.com/lit/ds/symlink/opa569.pdf, http://www.ti.com/lit/an/slma004b/slma004b.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +23 +21 +Package_SO +SO-20-1EP_7.52x12.825mm_P1.27mm_EP6.045x12.09mm_Mask3.56x4.47mm_ThermalVias +SO, 20 Pin (http://www.ti.com/lit/ds/symlink/opa569.pdf, http://www.ti.com/lit/an/slma004b/slma004b.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +51 +21 +Package_SO +SO-20_5.3x12.6mm_P1.27mm +SO, 20 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +20 +20 +Package_SO +SO-20_12.8x7.5mm_P1.27mm +SO-20, 12.8x7.5mm, https://www.nxp.com/docs/en/data-sheet/SA605.pdf +S0-20 +0 +20 +20 +Package_SO +SO-24_5.3x15mm_P1.27mm +SO, 24 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +24 +24 +Package_SO +SOIC-4_4.55x2.6mm_P1.27mm +SOIC, 4 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=12884&prodName=TLP291), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +4 +4 +Package_SO +SOIC-4_4.55x3.7mm_P2.54mm +SOIC, 6 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=11791&prodName=TLP185), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +4 +4 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.29x3mm +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.29x3mm_ThermalVias +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.3mm +SOIC, 8 Pin (http://www.allegromicro.com/~/media/Files/Datasheets/A4950-Datasheet.ashx#page=8), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.3mm_ThermalVias +SOIC, 8 Pin (http://www.allegromicro.com/~/media/Files/Datasheets/A4950-Datasheet.ashx#page=8), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.81mm +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.81mm_ThermalVias +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.95x4.9mm_Mask2.71x3.4mm +SOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lm5017.pdf#page=31), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +14 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.95x4.9mm_Mask2.71x3.4mm_ThermalVias +SOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lm5017.pdf#page=31), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +23 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.514x3.2mm +SOIC, 8 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/hip2100.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.514x3.2mm_ThermalVias +SOIC, 8 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/hip2100.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-N7_3.9x4.9mm_P1.27mm +8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], pin 7 removed (Microchip Packaging Specification 00000049BS.pdf, http://www.onsemi.com/pub/Collateral/NCP1207B.PDF) +SOIC 1.27 +0 +7 +7 +Package_SO +SOIC-8_3.9x4.9mm_P1.27mm +SOIC, 8 Pin (JEDEC MS-012AA, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_narrow-r/r_8.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-8_5.23x5.23mm_P1.27mm +SOIC, 8 Pin (http://www.winbond.com/resource-files/w25q32jv%20revg%2003272018%20plus.pdf#page=68), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-8_5.275x5.275mm_P1.27mm +SOIC, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/20005045C.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-8_7.5x5.85mm_P1.27mm +SOIC, 8 Pin (http://www.ti.com/lit/ml/mpds382b/mpds382b.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-14-16_3.9x9.9mm_P1.27mm +SOIC, 16 Pin package with pin 2 and 13 removed for voltage clearance (UCC256301, https://www.ti.com/lit/ds/symlink/ucc256301.pdf) +SOIC SO +0 +14 +14 +Package_SO +SOIC-14W_7.5x9mm_P1.27mm +SOIC, 14 Pin (JEDEC MS-013AF, https://www.analog.com/media/en/package-pcb-resources/package/54614177245586rw_14.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +14 +14 +Package_SO +SOIC-14_3.9x8.7mm_P1.27mm +SOIC, 14 Pin (JEDEC MS-012AB, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_narrow-r/r_14.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +14 +14 +Package_SO +SOIC-16W-12_7.5x10.3mm_P1.27mm +SOIC-16 With 12 Pin Placed - Wide, 7.50 mm Body [SOIC] (https://docs.broadcom.com/docs/AV02-0169EN) +SOIC 1.27 16 12 Wide +0 +12 +12 +Package_SO +SOIC-16W_5.3x10.2mm_P1.27mm +16-Lead Plastic Small Outline (SO) - Wide, 5.3 mm Body (http://www.ti.com/lit/ml/msop002a/msop002a.pdf) +SOIC 1.27 +0 +16 +16 +Package_SO +SOIC-16W_7.5x10.3mm_P1.27mm +SOIC, 16 Pin (JEDEC MS-013AA, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_wide-rw/rw_16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-16W_7.5x12.8mm_P1.27mm +SOIC, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ri_soic_ic/ri_16_1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-16_3.9x9.9mm_P1.27mm +SOIC, 16 Pin (JEDEC MS-012AC, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_narrow-r/r_16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-16_4.55x10.3mm_P1.27mm +SOIC, 16 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=12858&prodName=TLP291-4), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-18W_7.5x11.6mm_P1.27mm +SOIC, 18 Pin (JEDEC MS-013AB, https://www.analog.com/media/en/package-pcb-resources/package/33254132129439rw_18.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +18 +18 +Package_SO +SOIC-20W_7.5x12.8mm_P1.27mm +SOIC, 20 Pin (JEDEC MS-013AC, https://www.analog.com/media/en/package-pcb-resources/package/233848rw_20.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +20 +Package_SO +SOIC-24W_7.5x15.4mm_P1.27mm +SOIC, 24 Pin (JEDEC MS-013AD, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_wide-rw/RW_24.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +24 +24 +Package_SO +SOIC-28W_7.5x17.9mm_P1.27mm +SOIC, 28 Pin (JEDEC MS-013AE, https://www.analog.com/media/en/package-pcb-resources/package/35833120341221rw_28.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +28 +28 +Package_SO +SOIC-28W_7.5x18.7mm_P1.27mm +SOIC, 28 Pin (https://www.akm.com/akm/en/file/datasheet/AK5394AVS.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +28 +28 +Package_SO +SOIJ-8_5.3x5.3mm_P1.27mm +8-Lead Plastic Small Outline (SM) - Medium, 5.28 mm Body [SOIC] (see Microchip Packaging Specification 00000049BS.pdf) +SOIC 1.27 +0 +8 +8 +Package_SO +SOJ-36_10.16x23.49mm_P1.27mm +SOJ, 36 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOJ SO +0 +36 +36 +Package_SO +SOP-4_3.8x4.1mm_P2.54mm +SOP, 4 Pin (http://www.ixysic.com/home/pdfs.nsf/www/CPC1017N.pdf/$file/CPC1017N.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +4 +4 +Package_SO +SOP-4_4.4x2.6mm_P1.27mm +SOP, 4 Pin (http://www.vishay.com/docs/83510/tcmt1100.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +4 +4 +Package_SO +SOP-8-1EP_4.57x4.57mm_P1.27mm_EP4.57x4.45mm +SOP, 8 Pin (https://ww2.minicircuits.com/case_style/XX112.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +13 +9 +Package_SO +SOP-8-1EP_4.57x4.57mm_P1.27mm_EP4.57x4.45mm_ThermalVias +SOP, 8 Pin (https://ww2.minicircuits.com/case_style/XX112.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +20 +9 +Package_SO +SOP-8_3.9x4.9mm_P1.27mm +SOP, 8 Pin (http://www.macronix.com/Lists/Datasheet/Attachments/7534/MX25R3235F,%20Wide%20Range,%2032Mb,%20v1.6.pdf#page=79), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-8_3.76x4.96mm_P1.27mm +SOP, 8 Pin (https://ww2.minicircuits.com/case_style/XX211.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-8_5.28x5.23mm_P1.27mm +SOP, 8 Pin (http://www.macronix.com/Lists/Datasheet/Attachments/7534/MX25R3235F,%20Wide%20Range,%2032Mb,%20v1.6.pdf#page=80), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-8_6.62x9.15mm_P2.54mm +SOP, 8 Pin (http://www.ti.com/lit/ds/symlink/iso1050.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-16_3.9x9.9mm_P1.27mm +SOP, 16 Pin (https://www.diodes.com/assets/Datasheets/PAM8403.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +16 +16 +Package_SO +SOP-16_4.4x10.4mm_P1.27mm +16-Lead Plastic Small Outline http://www.vishay.com/docs/49633/sg2098.pdf +SOP 1.27 +0 +16 +16 +Package_SO +SOP-16_4.55x10.3mm_P1.27mm +SOP, 16 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=12855&prodName=TLP290-4), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +16 +16 +Package_SO +SOP-18_7x12.5mm_P1.27mm +SOP, 18 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=30523), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +18 +18 +Package_SO +SOP-20_7.5x12.8mm_P1.27mm +SOP, 20 Pin (https://www.holtek.com/documents/10179/116723/sop20-300.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +20 +20 +Package_SO +SOP-24_7.5x15.4mm_P1.27mm +SOP, 24 Pin (http://www.issi.com/WW/pdf/31FL3218.pdf#page=14), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +24 +24 +Package_SO +SSO-4_6.7x5.1mm_P2.54mm_Clearance8mm +4-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://www.vishay.com/docs/84299/vor1142b4.pdf +SSO Stretched SO SOIC 2.54 +0 +4 +4 +Package_SO +SSO-6_6.8x4.6mm_P1.27mm_Clearance7mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC 1.27 +0 +6 +6 +Package_SO +SSO-6_6.8x4.6mm_P1.27mm_Clearance8mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC 1.27 +0 +6 +6 +Package_SO +SSO-8_6.7x9.8mm_P2.54mm_Clearance8mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://www.vishay.com/docs/83831/lh1533ab.pdf +SSO Stretched SO SOIC Pitch 2.54 +0 +8 +8 +Package_SO +SSO-8_6.8x5.9mm_P1.27mm_Clearance7mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSO-8_6.8x5.9mm_P1.27mm_Clearance8mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSO-8_9.6x6.3mm_P1.27mm_Clearance10.5mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSO-8_13.6x6.3mm_P1.27mm_Clearance14.2mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSOP-8_2.95x2.8mm_P0.65mm +SSOP-8 2.9 x2.8mm Pitch 0.65mm +SSOP-8 2.95x2.8mm Pitch 0.65mm +0 +8 +8 +Package_SO +SSOP-8_3.9x5.05mm_P1.27mm +SSOP, 8 Pin (http://www.fujitsu.com/downloads/MICRO/fsa/pdf/products/memory/fram/MB85RS16-DS501-00014-6v0-E.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +8 +8 +Package_SO +SSOP-8_3.95x5.21x3.27mm_P1.27mm +SSOP-8 3.95x5.21x3.27mm Pitch 1.27mm +SSOP-8 3.95x5.21x3.27mm 1.27mm +0 +8 +8 +Package_SO +SSOP-8_5.25x5.24mm_P1.27mm +SSOP, 8 Pin (http://www.fujitsu.com/ca/en/Images/MB85RS2MT-DS501-00023-1v0-E.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +8 +8 +Package_SO +SSOP-10_3.9x4.9mm_P1.00mm +10-Lead SSOP, 3.9 x 4.9mm body, 1.00mm pitch (http://www.st.com/resource/en/datasheet/viper01.pdf) +SSOP 3.9 4.9 1.00 +0 +10 +10 +Package_SO +SSOP-14_5.3x6.2mm_P0.65mm +SSOP14: plastic shrink small outline package; 14 leads; body width 5.3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot337-1_po.pdf) +SSOP 0.65 +0 +14 +14 +Package_SO +SSOP-16_3.9x4.9mm_P0.635mm +SSOP16: plastic shrink small outline package; 16 leads; body width 3.9 mm; lead pitch 0.635; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot519-1_po.pdf) +SSOP 0.635 +0 +16 +16 +Package_SO +SSOP-16_4.4x5.2mm_P0.65mm +SSOP16: plastic shrink small outline package; 16 leads; body width 4.4 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot369-1_po.pdf) +SSOP 0.65 +0 +16 +16 +Package_SO +SSOP-16_5.3x6.2mm_P0.65mm +SSOP16: plastic shrink small outline package; 16 leads; body width 5.3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot338-1_po.pdf) +SSOP 0.65 +0 +16 +16 +Package_SO +SSOP-18_4.4x6.5mm_P0.65mm +SSOP18: plastic shrink small outline package; 18 leads; body width 4.4 mm (http://toshiba.semicon-storage.com/info/docget.jsp?did=30523&prodName=TBD62783APG) +SSOP 0.65 +0 +18 +18 +Package_SO +SSOP-20_3.9x8.7mm_P0.635mm +SSOP20: plastic shrink small outline package; 24 leads; body width 3.9 mm; lead pitch 0.635; (see http://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT231X.pdf) +SSOP 0.635 +0 +20 +20 +Package_SO +SSOP-20_4.4x6.5mm_P0.65mm +SSOP20: plastic shrink small outline package; 20 leads; body width 4.4 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot266-1_po.pdf) +SSOP 0.65 +0 +20 +20 +Package_SO +SSOP-20_5.3x7.2mm_P0.65mm +SSOP, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/40001800C.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +20 +20 +Package_SO +SSOP-24_3.9x8.7mm_P0.635mm +SSOP24: plastic shrink small outline package; 24 leads; body width 3.9 mm; lead pitch 0.635; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot556-1_po.pdf) +SSOP 0.635 +0 +24 +24 +Package_SO +SSOP-24_5.3x8.2mm_P0.65mm +24-Lead Plastic Shrink Small Outline (SS)-5.30 mm Body [SSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.65 +0 +24 +24 +Package_SO +SSOP-28_3.9x9.9mm_P0.635mm +SSOP28: plastic shrink small outline package; 28 leads; body width 3.9 mm; lead pitch 0.635; (see http://cds.linear.com/docs/en/datasheet/38901fb.pdf) +SSOP 0.635 +0 +28 +28 +Package_SO +SSOP-28_5.3x10.2mm_P0.65mm +28-Lead Plastic Shrink Small Outline (SS)-5.30 mm Body [SSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.65 +0 +28 +28 +Package_SO +SSOP-32_11.305x20.495mm_P1.27mm +SSOP, 32 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +32 +32 +Package_SO +SSOP-44_5.3x12.8mm_P0.5mm +44-Lead Plastic Shrink Small Outline (SS)-5.30 mm Body [SSOP] (http://cds.linear.com/docs/en/datasheet/680313fa.pdf) +SSOP 0.5 +0 +44 +44 +Package_SO +SSOP-48_7.5x15.9mm_P0.635mm +SSOP48: plastic shrink small outline package; 48 leads; body width 7.5 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot370-1_po.pdf) +SSOP 0.635 +0 +48 +48 +Package_SO +SSOP-56_7.5x18.5mm_P0.635mm +SSOP56: plastic shrink small outline package; 56 leads; body width 7.5 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot371-1_po.pdf) +SSOP 0.635 +0 +56 +56 +Package_SO +STC_SOP-16_3.9x9.9mm_P1.27mm +STC SOP, 16 Pin (https://www.stcmicro.com/datasheet/STC15F2K60S2-en.pdf#page=156), generated with kicad-footprint-generator ipc_gullwing_generator.py +STC SOP SO +0 +16 +16 +Package_SO +ST_MultiPowerSO-30 +MultiPowerSO-30 3EP 16.0x17.2mm Pitch 1mm (http://www.st.com/resource/en/datasheet/vnh2sp30-e.pdf) +MultiPowerSO-30 3EP 16.0x17.2mm Pitch 1mm +0 +33 +33 +Package_SO +ST_PowerSSO-24_SlugDown +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7266p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm +0 +25 +25 +Package_SO +ST_PowerSSO-24_SlugDown_ThermalVias +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7266p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm +0 +38 +25 +Package_SO +ST_PowerSSO-24_SlugUp +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7266p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm +0 +24 +24 +Package_SO +ST_PowerSSO-36_SlugDown +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7492p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm +0 +37 +37 +Package_SO +ST_PowerSSO-36_SlugDown_ThermalVias +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7492p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm +0 +50 +37 +Package_SO +ST_PowerSSO-36_SlugUp +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7492p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm +0 +36 +36 +Package_SO +TI_SO-PowerPAD-8 +8-Lead Plastic PSOP, Exposed Die Pad (TI DDA0008B, see http://www.ti.com/lit/ds/symlink/lm3404.pdf) +SSOP 0.50 exposed pad +0 +12 +9 +Package_SO +TI_SO-PowerPAD-8_ThermalVias +8-pin HTSOP package with 1.27mm pin pitch, compatible with SOIC-8, 3.9x4.9mm² body, exposed pad, thermal vias with large copper area, as proposed in http://www.ti.com/lit/ds/symlink/tps5430.pdf +HTSOP 1.27 +0 +19 +9 +Package_SO +TSOP-5_1.65x3.05mm_P0.95mm +TSOP-5 package (comparable to TSOT-23), https://www.vishay.com/docs/71200/71200.pdf +Jedec MO-193C TSOP-5L +0 +5 +5 +Package_SO +TSOP-6_1.65x3.05mm_P0.95mm +TSOP-6 package (comparable to TSOT-23), https://www.vishay.com/docs/71200/71200.pdf +Jedec MO-193C TSOP-6L +0 +6 +6 +Package_SO +TSOP-I-28_11.8x8mm_P0.55mm +TSOP I, 28 pins, 18.8x8mm body, 0.55mm pitch, IPC-calculated pads (http://ww1.microchip.com/downloads/en/devicedoc/doc0807.pdf) +TSOP I 28 pins +0 +28 +28 +Package_SO +TSOP-I-32_11.8x8mm_P0.5mm +TSOP-I, 32 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSOP-I SO +0 +32 +32 +Package_SO +TSOP-I-32_18.4x8mm_P0.5mm +TSOP I, 32 pins, 18.4x8mm body (https://www.micron.com/~/media/documents/products/technical-note/nor-flash/tn1225_land_pad_design.pdf, http://www.fujitsu.com/downloads/MICRO/fma/pdfmcu/f32pm25.pdf) +TSOP I 32 +0 +32 +32 +Package_SO +TSOP-I-32_18.4x8mm_P0.5mm_Reverse +TSOP I, 32 pins, 18.4x8mm body (http://www.futurlec.com/Datasheet/Memory/628128.pdf), reverse mount +TSOP I 32 reverse +0 +32 +32 +Package_SO +TSOP-I-48_18.4x12mm_P0.5mm +TSOP I, 32 pins, 18.4x8mm body (https://www.micron.com/~/media/documents/products/technical-note/nor-flash/tn1225_land_pad_design.pdf) +TSOP I 32 +0 +48 +48 +Package_SO +TSOP-I-56_18.4x14mm_P0.5mm +TSOP I, 32 pins, 18.4x8mm body (https://www.micron.com/~/media/documents/products/technical-note/nor-flash/tn1225_land_pad_design.pdf) +TSOP I 32 +0 +56 +56 +Package_SO +TSOP-II-32_21.0x10.2mm_P1.27mm +32-lead plastic TSOP; Type II +TSOP-II 32 +0 +32 +32 +Package_SO +TSOP-II-44_10.16x18.41mm_P0.8mm +TSOP-II, 44 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSOP-II SO +0 +44 +44 +Package_SO +TSOP-II-54_22.2x10.16mm_P0.8mm +54-lead TSOP typ II package +TSOPII TSOP2 +0 +54 +54 +Package_SO +TSSOP-4_4.4x5mm_P4mm +TSSOP, 4 Pin (https://www.onsemi.com/pub/Collateral/MDB8S-D.PDF#page=4), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +4 +4 +Package_SO +TSSOP-8_3x3mm_P0.65mm +TSSOP8: plastic thin shrink small outline package; 8 leads; body width 3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot505-1_po.pdf) +SSOP 0.65 +0 +8 +8 +Package_SO +TSSOP-8_4.4x3mm_P0.65mm +TSSOP, 8 Pin (JEDEC MO-153 Var AA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +8 +8 +Package_SO +TSSOP-10_3x3mm_P0.5mm +TSSOP10: plastic thin shrink small outline package; 10 leads; body width 3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot552-1_po.pdf) +SSOP 0.5 +0 +10 +10 +Package_SO +TSSOP-14-1EP_4.4x5mm_P0.65mm +14-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body [TSSOP] with exposed pad (http://cds.linear.com/docs/en/datasheet/34301fa.pdf) +SSOP 0.65 exposed pad +0 +18 +15 +Package_SO +TSSOP-14_4.4x5mm_P0.65mm +TSSOP, 14 Pin (JEDEC MO-153 Var AB-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +14 +14 +Package_SO +TSSOP-16-1EP_4.4x5mm_P0.65mm +FE Package; 16-Lead Plastic TSSOP (4.4mm); Exposed Pad Variation BB; (see Linear Technology 1956f.pdf) +SSOP 0.65 +0 +24 +17 +Package_SO +TSSOP-16_4.4x5mm_P0.65mm +TSSOP, 16 Pin (JEDEC MO-153 Var AB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +16 +16 +Package_SO +TSSOP-20_4.4x5mm_P0.5mm +TSSOP, 20 Pin (JEDEC MO-153 Var BA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +20 +20 +Package_SO +TSSOP-20_4.4x6.5mm_P0.65mm +TSSOP, 20 Pin (JEDEC MO-153 Var AC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +20 +20 +Package_SO +TSSOP-24_4.4x5mm_P0.4mm +TSSOP, 24 Pin (JEDEC MO-153 Var CA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-24_4.4x6.5mm_P0.5mm +TSSOP, 24 Pin (JEDEC MO-153 Var BB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-24_4.4x7.8mm_P0.65mm +TSSOP, 24 Pin (JEDEC MO-153 Var AD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-24_6.1x7.8mm_P0.65mm +TSSOP, 24 Pin (JEDEC MO-153 Var DA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-28-1EP_4.4x9.7mm_P0.65mm +TSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; Exposed Pad Variation; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot361-1_po.pdf) +SSOP 0.65 +0 +36 +29 +Package_SO +TSSOP-28_4.4x7.8mm_P0.5mm +TSSOP, 28 Pin (JEDEC MO-153 Var BC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_4.4x9.7mm_P0.65mm +TSSOP, 28 Pin (JEDEC MO-153 Var AE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_6.1x7.8mm_P0.5mm +TSSOP, 28 Pin (JEDEC MO-153 Var EA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_6.1x9.7mm_P0.65mm +TSSOP, 28 Pin (JEDEC MO-153 Var DB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_8x9.7mm_P0.65mm +TSSOP, 28 Pin (JEDEC MO-153 Var GA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-30_4.4x7.8mm_P0.5mm +TSSOP, 30 Pin (JEDEC MO-153 Var BC-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +30 +30 +Package_SO +TSSOP-30_6.1x9.7mm_P0.65mm +TSSOP, 30 Pin (JEDEC MO-153 Var DB-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +30 +30 +Package_SO +TSSOP-32_4.4x6.5mm_P0.4mm +TSSOP, 32 Pin (JEDEC MO-153 Var CB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +32 +32 +Package_SO +TSSOP-32_6.1x11mm_P0.65mm +TSSOP, 32 Pin (JEDEC MO-153 Var DC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +32 +32 +Package_SO +TSSOP-32_8x11mm_P0.65mm +TSSOP, 32 Pin (JEDEC MO-153 Var GB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +32 +32 +Package_SO +TSSOP-36_4.4x7.8mm_P0.4mm +TSSOP, 36 Pin (JEDEC MO-153 Var CC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_4.4x9.7mm_P0.5mm +TSSOP, 36 Pin (JEDEC MO-153 Var BD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_6.1x7.8mm_P0.4mm +TSSOP, 36 Pin (JEDEC MO-153 Var FA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_6.1x9.7mm_P0.5mm +TSSOP, 36 Pin (JEDEC MO-153 Var EB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_6.1x12.5mm_P0.65mm +TSSOP, 36 Pin (JEDEC MO-153 Var DD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_8x9.7mm_P0.5mm +TSSOP, 36 Pin (JEDEC MO-153 Var HA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_8x12.5mm_P0.65mm +TSSOP, 36 Pin (JEDEC MO-153 Var GC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-38_4.4x9.7mm_P0.5mm +TSSOP, 38 Pin (JEDEC MO-153 Var BD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +38 +38 +Package_SO +TSSOP-38_6.1x12.5mm_P0.65mm +TSSOP, 38 Pin (JEDEC MO-153 Var DD-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +38 +38 +Package_SO +TSSOP-40_6.1x11mm_P0.5mm +TSSOP, 40 Pin (JEDEC MO-153 Var EC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-40_6.1x14mm_P0.65mm +TSSOP, 40 Pin (JEDEC MO-153 Var DE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-40_8x11mm_P0.5mm +TSSOP, 40 Pin (JEDEC MO-153 Var HB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-40_8x14mm_P0.65mm +TSSOP, 40 Pin (JEDEC MO-153 Var GD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-44_4.4x11.2mm_P0.5mm +TSSOP44: plastic thin shrink small outline package; 44 leads; body width 4.4 mm (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot510-1_po.pdf) +SSOP 0.5 +0 +44 +44 +Package_SO +TSSOP-44_4.4x11mm_P0.5mm +TSSOP, 44 Pin (JEDEC MO-153 Var BE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +44 +44 +Package_SO +TSSOP-44_6.1x11mm_P0.5mm +TSSOP, 44 Pin (JEDEC MO-153 Var EC-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +44 +44 +Package_SO +TSSOP-48_4.4x9.7mm_P0.4mm +TSSOP, 48 Pin (JEDEC MO-153 Var CD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_6.1x9.7mm_P0.4mm +TSSOP, 48 Pin (JEDEC MO-153 Var FB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_6.1x12.5mm_P0.5mm +TSSOP, 48 Pin (JEDEC MO-153 Var ED https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_8x9.7mm_P0.4mm +TSSOP, 48 Pin (JEDEC MO-153 Var JA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_8x12.5mm_P0.5mm +TSSOP, 48 Pin (JEDEC MO-153 Var HC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-50_4.4x12.5mm_P0.5mm +TSSOP, 50 Pin (JEDEC MO-153 Var BF https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +50 +50 +Package_SO +TSSOP-52_6.1x11mm_P0.4mm +TSSOP, 52 Pin (JEDEC MO-153 Var FC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +52 +52 +Package_SO +TSSOP-52_8x11mm_P0.4mm +TSSOP, 52 Pin (JEDEC MO-153 Var JB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +52 +52 +Package_SO +TSSOP-56_6.1x12.5mm_P0.4mm +TSSOP, 56 Pin (JEDEC MO-153 Var FD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-56_6.1x14mm_P0.5mm +TSSOP, 56 Pin (JEDEC MO-153 Var EE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-56_8x12.5mm_P0.4mm +TSSOP, 56 Pin (JEDEC MO-153 Var JC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-56_8x14mm_P0.5mm +TSSOP, 56 Pin (JEDEC MO-153 Var HD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-60_8x12.5mm_P0.4mm +TSSOP, 60 Pin (JEDEC MO-153 Var JC-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +60 +60 +Package_SO +TSSOP-64_6.1x14mm_P0.4mm +TSSOP, 64 Pin (JEDEC MO-153 Var FE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +64 +64 +Package_SO +TSSOP-64_6.1x17mm_P0.5mm +TSSOP, 64 Pin (JEDEC MO-153 Var EF https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +64 +64 +Package_SO +TSSOP-64_8x14mm_P0.4mm +TSSOP, 64 Pin (JEDEC MO-153 Var JD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +64 +64 +Package_SO +TSSOP-68_8x14mm_P0.4mm +TSSOP, 68 Pin (JEDEC MO-153 Var JD-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +68 +68 +Package_SO +TSSOP-80_6.1x17mm_P0.4mm +TSSOP, 80 Pin (JEDEC MO-153 Var FF https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +80 +80 +Package_SO +Texas_HSOP-8-1EP_3.9x4.9mm_P1.27mm +Texas Instruments HSOP 9, 1.27mm pitch, 3.9x4.9mm body, exposed pad, DDA0008J (http://www.ti.com/lit/ds/symlink/tps5430.pdf) +HSOP 1.27 +0 +11 +9 +Package_SO +Texas_HSOP-8-1EP_3.9x4.9mm_P1.27mm_ThermalVias +Texas Instruments HSOP 9, 1.27mm pitch, 3.9x4.9mm body, exposed pad, thermal vias, DDA0008J (http://www.ti.com/lit/ds/symlink/tps5430.pdf) +HSOP 1.27 +0 +20 +9 +Package_SO +Texas_HTSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.95x4.9mm_Mask2.4x3.1mm_ThermalVias +8-pin HTSOP package with 1.27mm pin pitch, compatible with SOIC-8, 3.9x4.9mm body, exposed pad, thermal vias, http://www.ti.com/lit/ds/symlink/drv8870.pdf +HTSOP 1.27 +0 +18 +9 +Package_SO +Texas_PWP0020A +20-Pin Thermally Enhanced Thin Shrink Small-Outline Package, Body 4.4x6.5x1.1mm, Pad 3.0x4.2mm, Texas Instruments (see http://www.ti.com/lit/ds/symlink/lm5118.pdf) +PWP HTSSOP 0.65mm +0 +25 +21 +Package_SO +Texas_R-PDSO-G8_EP2.95x4.9mm_Mask2.4x3.1mm +HSOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lmr14030.pdf#page=28, http://www.ti.com/lit/ml/msoi002j/msoi002j.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOIC SO +0 +16 +9 +Package_SO +Texas_R-PDSO-G8_EP2.95x4.9mm_Mask2.4x3.1mm_ThermalVias +HSOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lmr14030.pdf#page=28, http://www.ti.com/lit/ml/msoi002j/msoi002j.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOIC SO +0 +23 +9 +Package_SO +Texas_R-PDSO-N5 +Plastic Small outline http://www.ti.com/lit/ml/mpds158c/mpds158c.pdf +SOT23 R-PDSO-N5 +0 +5 +5 +Package_SO +VSO-40_7.6x15.4mm_P0.762mm +VSO40: plastic very small outline package; 40 leads (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot158-1_po.pdf) +SSOP 0.762 +0 +40 +40 +Package_SO +VSO-56_11.1x21.5mm_P0.75mm +VSO56: plastic very small outline package; 56 leads (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot190-1_po.pdf) +SSOP 0.75 +0 +56 +56 +Package_SO +VSSOP-8_2.3x2mm_P0.5mm +VSSOP-8 2.3x2mm Pitch 0.5mm +VSSOP-8 2.3x2mm Pitch 0.5mm +0 +8 +8 +Package_SO +VSSOP-8_2.4x2.1mm_P0.5mm +http://www.ti.com/lit/ml/mpds050d/mpds050d.pdf +VSSOP DCU R-PDSO-G8 Pitch0.5mm +0 +8 +8 +Package_SO +VSSOP-8_3.0x3.0mm_P0.65mm +VSSOP-8 3.0 x 3.0, http://www.ti.com/lit/ds/symlink/lm75b.pdf +VSSOP-8 3.0 x 3.0 +0 +8 +8 +Package_SO +VSSOP-10_3x3mm_P0.5mm +VSSOP, 10 Pin (http://www.ti.com/lit/ds/symlink/ads1115.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +VSSOP SO +0 +10 +10 +Package_SO +Vishay_PowerPAK_1212-8_Dual +PowerPAK 1212-8 Dual (https://www.vishay.com/docs/71656/ppak12128.pdf, https://www.vishay.com/docs/72598/72598.pdf) +Vishay_PowerPAK_1212-8_Dual +0 +6 +6 +Package_SO +Vishay_PowerPAK_1212-8_Single +PowerPAK 1212-8 Single (https://www.vishay.com/docs/71656/ppak12128.pdf, https://www.vishay.com/docs/72597/72597.pdf) +Vishay PowerPAK 1212-8 Single +0 +5 +5 +Package_SO +Zetex_SM8 +Zetex, SMD, 8 pin package (http://datasheet.octopart.com/ZDT6758TA-Zetex-datasheet-68057.pdf) +Zetex SM8 +0 +8 +8 +Package_SON +Diodes_PowerDI3333-8 +Diodes Incorporated PowerDI3333-8, Plastic Dual Flat No Lead Package, 3.3x3.3x0.8mm Body, https://www.diodes.com/assets/Package-Files/PowerDI3333-8.pdf +PowerDI 0.65 +0 +13 +5 +Package_SON +Fairchild_DualPower33-6_3x3mm +Fairchild Power33 MOSFET package, 3x3mm (see https://www.fairchildsemi.com/datasheets/FD/FDMC8032L.pdf) +mosfet +0 +18 +6 +Package_SON +Fairchild_MicroPak-6_1.0x1.45mm_P0.5mm +Fairchild-specific MicroPak-6 1.0x1.45mm Pitch 0.5mm https://www.nxp.com/docs/en/application-note/AN10343.pdff +Fairchild-specific MicroPak-6 1.0x1.45mm Pitch 0.5mm +0 +6 +6 +Package_SON +Fairchild_MicroPak2-6_1.0x1.0mm_P0.35mm +Fairchild-specific MicroPak2-6 1.0x1.0mm Pitch 0.35mm https://www.nxp.com/docs/en/application-note/AN10343.pdff +Fairchild-specific MicroPak2-6 1.0x1.0mm Pitch 0.35mm +0 +6 +6 +Package_SON +HUSON-3-1EP_2x2mm_P1.3mm_EP1.1x1.6mm +HUSON, 3 Pin, SOT1061 (Ref: https://assets.nexperia.com/documents/data-sheet/PMEG2020CPA.pdf) +huson nolead SOT1061 +0 +4 +3 +Package_SON +HVSON-8-1EP_3x3mm_P0.65mm_EP1.6x2.4mm +HVSON, 8 Pin (https://www.nxp.com/docs/en/data-sheet/TJA1051.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +HVSON NoLead +0 +13 +9 +Package_SON +HVSON-8-1EP_4x4mm_P0.8mm_EP2.2x3.1mm +HVSON, 8 Pin (https://www.nxp.com/docs/en/data-sheet/PCF8523.pdf (page 57)), generated with kicad-footprint-generator ipc_noLead_generator.py +HVSON NoLead +0 +13 +9 +Package_SON +Infineon_PG-LSON-8-1 +https://www.infineon.com/cms/en/product/packages/PG-LSON/PG-LSON-8-1/ +PG-LSON-8-1 +0 +17 +9 +Package_SON +Infineon_PG-TISON-8-2 +Infineon, PG-TISON-8-2, 5x6x1.15mm, 1.27mm Pitch, Exposed Paddle, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-2/ +tison +0 +23 +7 +Package_SON +Infineon_PG-TISON-8-3 +Infineon, PG-TISON-8-2, 5x6x1.15mm, 1.27mm Pitch, Exposed Paddle, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-2/ +tison +0 +23 +7 +Package_SON +Infineon_PG-TISON-8-4 +Infineon, PG-TISON-8-4, 5x6x1.15mm, 1.27mm Pitch, Exposed Paddle, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-4/ +tison +0 +26 +8 +Package_SON +Infineon_PG-TISON-8-5 +Infineon, PG-TISON-8-5, 8x8x1.1mm, 1mm Pitch, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-5/ +tison +0 +34 +8 +Package_SON +NXP_XSON-16 +http://www.nxp.com/documents/outline_drawing/SOT1341-1.pdf +NXP XSON SOT-1341 +0 +16 +16 +Package_SON +ROHM_VML0806 +VML0806, Rohm (http://rohmfs.rohm.com/en/techdata_basic/transistor/soldering_condition/VML0806_Soldering_Condition.pdf, http://rohmfs.rohm.com/en/products/databook/package/spec/discrete/vml0806_tr-e.pdf) +ROHM VML0806 +0 +3 +3 +Package_SON +RTC_SMD_MicroCrystal_C3_2.5x3.7mm +MicroCrystal C3 2.5x3.7mm, https://www.microcrystal.com/fileadmin/Media/Products/RTC/Datasheet/RV-1805-C3.pdf +RTC C3 +0 +10 +10 +Package_SON +SON-8-1EP_3x2mm_P0.5mm_EP1.4x1.6mm +SON, 8 Pin (http://www.fujitsu.com/downloads/MICRO/fsa/pdf/products/memory/fram/MB85RS16-DS501-00014-6v0-E.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +SON NoLead +0 +13 +9 +Package_SON +Texas_DQK +Texas WSON-6 DQK, http://www.ti.com/lit/ds/symlink/csd16301q2.pdf +Texas WSON6 2x2mm +0 +10 +8 +Package_SON +Texas_DRC0010J +Texas DRC0010J, VSON10 3x3mm Body, 0.5mm Pitch, http://www.ti.com/lit/ds/symlink/tps63000.pdf +Texas VSON10 3x3mm +0 +17 +11 +Package_SON +Texas_DRC0010J_ThermalVias +Texas DRC0010J, VSON10 3x3mm Body, 0.5mm Pitch, http://www.ti.com/lit/ds/symlink/tps63000.pdf +Texas VSON10 3x3mm +0 +21 +11 +Package_SON +Texas_DSC0010J +3x3mm Body, 0.5mm Pitch, DSC0010J, WSON, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 DSC0010J WSON +0 +33 +11 +Package_SON +Texas_DSC0010J_ThermalVias +3x3mm Body, 0.5mm Pitch, DSC0010J, WSON, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 DSC0010J WSON +0 +39 +11 +Package_SON +Texas_PWSON-N6 +Plastic Small Outline No-Lead http://www.ti.com/lit/ml/mpds176e/mpds176e.pdf +Plastic Small Outline No-Lead +0 +7 +7 +Package_SON +Texas_R-PWSON-N12_EP0.4x2mm +http://www.ti.com/lit/ds/symlink/tpd6f003.pdf +WSON SMD +0 +16 +13 +Package_SON +Texas_S-PDSO-N12 +http://www.ti.com/lit/ds/symlink/bq27441-g1.pdf +SON thermal pads +0 +44 +13 +Package_SON +Texas_S-PVSON-N8 +8-Lead Plastic VSON, 3x3mm Body, 0.65mm Pitch, S-PVSON-N8, http://www.ti.com/lit/ds/symlink/opa2333.pdf +DFN 0.65 S-PVSON-N8 +0 +21 +9 +Package_SON +Texas_S-PVSON-N8_ThermalVias +8-Lead Plastic VSON, 3x3mm Body, 0.65mm Pitch, S-PVSON-N8, http://www.ti.com/lit/ds/symlink/opa2333.pdf +DFN 0.65 S-PVSON-N8 +0 +27 +9 +Package_SON +Texas_S-PVSON-N10 +3x3mm Body, 0.5mm Pitch, S-PVSON-N10, DRC, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 S-PVSON-N10 DRC +0 +33 +11 +Package_SON +Texas_S-PVSON-N10_ThermalVias +3x3mm Body, 0.5mm Pitch, S-PVSON-N10, DRC, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 S-PVSON-N10 DRC +0 +39 +11 +Package_SON +Texas_S-PWSON-N8_EP1.2x2mm +WSON, 8 Pin (http://www.ti.com/lit/ds/symlink/lp2951.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +11 +9 +Package_SON +Texas_S-PWSON-N8_EP1.2x2mm_ThermalVias +WSON, 8 Pin (http://www.ti.com/lit/ds/symlink/lp2951.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +18 +9 +Package_SON +Texas_S-PWSON-N10 +3x3mm Body, 0.5mm Pitch, S-PWSON-N10, DSC, http://www.ti.com/lit/ds/symlink/tps63060.pdf +0.5 S-PWSON-N10 DSC +0 +41 +11 +Package_SON +Texas_S-PWSON-N10_ThermalVias +3x3mm Body, 0.5mm Pitch, S-PWSON-N10, DSC, http://www.ti.com/lit/ds/symlink/tps63060.pdf +0.5 S-PWSON-N10 DSC +0 +47 +11 +Package_SON +Texas_X2SON-4_1x1mm_P0.65mm +X2SON 5 pin 1x1mm package (Reference Datasheet: http://www.ti.com/lit/ds/sbvs193d/sbvs193d.pdf Reference part: TPS383x) [StepUp generated footprint] +X2SON +0 +13 +5 +Package_SON +USON-10_2.5x1.0mm_P0.5mm +USON-10 2.5x1.0mm_ Pitch 0.5mm http://www.ti.com/lit/ds/symlink/tpd4e02b04.pdf +USON-10 2.5x1.0mm Pitch 0.5mm +0 +10 +10 +Package_SON +USON-20_2x4mm_P0.4mm +USON-20 2x4mm Pitch 0.4mm http://www.ti.com/lit/ds/symlink/txb0108.pdf +USON-20 2x4mm Pitch 0.4mm +0 +20 +20 +Package_SON +VSON-8_3.3x3.3mm_P0.65mm_NexFET +8-Lead Plastic Dual Flat, No Lead Package (MF) - 3.3x3.3x1 mm Body [VSON] http://www.ti.com/lit/ds/symlink/csd87334q3d.pdf +VSON 0.65 +0 +12 +5 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.2x2mm +VSON, 10 Pin (http://rohmfs.rohm.com/en/products/databook/datasheet/ic/power/switching_regulator/bd8314nuv-e.pdf (Page 20)), generated with kicad-footprint-generator ipc_noLead_generator.py +VSON NoLead +0 +15 +11 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.2x2mm_ThermalVias +VSON, 10 Pin (http://rohmfs.rohm.com/en/products/databook/datasheet/ic/power/switching_regulator/bd8314nuv-e.pdf (Page 20)), generated with kicad-footprint-generator ipc_noLead_generator.py +VSON NoLead +0 +18 +11 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.65x2.4mm +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm http://chip.tomsk.ru/chip/chipdoc.nsf/Package/D8A64DD165C2AAD9472579400024FC41!OpenDocument +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm +0 +21 +11 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.65x2.4mm_ThermalVias +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm http://chip.tomsk.ru/chip/chipdoc.nsf/Package/D8A64DD165C2AAD9472579400024FC41!OpenDocument +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm +0 +27 +11 +Package_SON +VSONP-8-1EP_5x6_P1.27mm +SON, 8-Leads, Body 5x6x1mm, Pitch 1.27mm; (see Texas Instruments CSD18531Q5A http://www.ti.com/lit/ds/symlink/csd18531q5a.pdf) +VSONP 1.27 +0 +13 +3 +Package_SON +WSON-6-1EP_2x2mm_P0.65mm_EP1x1.6mm +WSON, 6 Pin (http://www.ti.com/lit/ds/symlink/tps61040.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +9 +7 +Package_SON +WSON-6-1EP_2x2mm_P0.65mm_EP1x1.6mm_ThermalVias +WSON, 6 Pin (http://www.ti.com/lit/ds/symlink/tps61040.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +12 +7 +Package_SON +WSON-6-1EP_3x3mm_P0.95mm +WSON6 3*3 MM, 0.95 PITCH; http://www.ti.com/lit/ds/symlink/lmr62421.pdf +WSON6 0.95 +0 +10 +7 +Package_SON +WSON-6_1.5x1.5mm_P0.5mm +WSON6, http://www.ti.com/lit/ds/symlink/tlv702.pdf +WSON6_1.5x1.5mm_P0.5mm +0 +6 +6 +Package_SON +WSON-8-1EP_2x2mm_P0.5mm_EP0.9x1.6mm +8-Lead Plastic WSON, 2x2mm Body, 0.5mm Pitch, WSON-8, http://www.ti.com/lit/ds/symlink/lm27761.pdf +WSON 8 1EP +0 +11 +9 +Package_SON +WSON-8-1EP_2x2mm_P0.5mm_EP0.9x1.6mm_ThermalVias +8-Lead Plastic WSON, 2x2mm Body, 0.5mm Pitch, WSON-8, http://www.ti.com/lit/ds/symlink/lm27761.pdf +WSON 8 1EP ThermalVias +0 +14 +9 +Package_SON +WSON-8-1EP_3x2.5mm_P0.5mm_EP1.2x1.5mm_PullBack +WSON, 8 Pin (http://www.ti.com/lit/ml/mpds400/mpds400.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +13 +9 +Package_SON +WSON-8-1EP_3x2.5mm_P0.5mm_EP1.2x1.5mm_PullBack_ThermalVias +WSON, 8 Pin (http://www.ti.com/lit/ml/mpds400/mpds400.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +18 +9 +Package_SON +WSON-8-1EP_3x3mm_P0.5mm_EP1.6x2.0mm +8-Lead Plastic WSON, 2x2mm Body, 0.5mm Pitch, WSON-8, http://www.ti.com/lit/ds/symlink/lm27761.pdf +WSON 8 1EP +0 +13 +9 +Package_SON +WSON-8-1EP_6x5mm_P1.27mm_EP3.4x4.3mm +WSON, 8 Pin (http://www.winbond.com/resource-files/w25q32jv%20revg%2003272018%20plus.pdf (page 68)), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +13 +9 +Package_SON +WSON-8-1EP_6x5mm_P1.27mm_EP3.4x4mm +WSON, 8 Pin (http://ww1.microchip.com/downloads/en/AppNotes/S72030.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +13 +9 +Package_SON +WSON-8_4x4mm_P0.8mm +http://www.ti.com/lit/ml/mpds406/mpds406.pdf +WSON8_4x4mm_P0.8mm +0 +9 +9 +Package_SON +WSON-10-1EP_2.5x2.5mm_P0.5mm_EP1.2x2mm +WSON, 10 Pin (http://www.ti.com/lit/gpn/tps63030#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +15 +11 +Package_SON +WSON-10-1EP_2.5x2.5mm_P0.5mm_EP1.2x2mm_ThermalVias +WSON, 10 Pin (http://www.ti.com/lit/gpn/tps63030#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +22 +11 +Package_SON +WSON-10-1EP_2x3mm_P0.5mm_EP0.84x2.4mm +WSON-10 package 2x3mm body, pitch 0.5mm, see http://www.ti.com/lit/ds/symlink/tps62177.pdf +WSON 0.5 +0 +14 +11 +Package_SON +WSON-10-1EP_2x3mm_P0.5mm_EP0.84x2.4mm_ThermalVias +WSON-10 package 2x3mm body, pitch 0.5mm, thermal vias and counter-pad, see http://www.ti.com/lit/ds/symlink/tps62177.pdf +WSON 0.5 thermal vias +0 +17 +11 +Package_SON +WSON-10-1EP_4x3mm_P0.5mm_EP2.2x2mm +10-Lead Plastic WSON, 4x3mm Body, 0.5mm Pitch (http://www.ti.com/lit/ds/symlink/lm4990.pdf) +WSON 0.5 +0 +15 +11 +Package_SON +WSON-12-1EP_3x2mm_P0.5mm_EP1x2.65 +WSON-12 http://www.ti.com/lit/ds/symlink/lm27762.pdf +WSON-12 +0 +15 +13 +Package_SON +WSON-12-1EP_3x2mm_P0.5mm_EP1x2.65_ThermalVias +WSON-12 http://www.ti.com/lit/ds/symlink/lm27762.pdf +WSON-12 +0 +19 +13 +Package_SON +WSON-12-1EP_4x4mm_P0.5mm_EP2.6x3mm +WSON, 12 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +17 +13 +Package_SON +WSON-12-1EP_4x4mm_P0.5mm_EP2.6x3mm_ThermalVias +WSON, 12 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +27 +13 +Package_SON +WSON-14-1EP_4.0x4.0mm_P0.5mm_EP2.6x2.6mm +14-Lead Plastic Dual Flat, No Lead Package - 4.0x4.0x0.8 mm Body [WSON], http://www.ti.com/lit/ml/mpds421/mpds421.pdf +NHL014B +0 +19 +15 +Package_SON +WSON-16_3.3x1.35_P0.4mm +WSON-16 3.3 x 1.35mm Pitch 0.4mm http://www.chip.tomsk.ru/chip/chipdoc.nsf/Package/C67E729A4D6C883A4725793E004C8739!OpenDocument +WSON-16 3.3 x 1.35mm Pitch 0.4mm +0 +20 +17 +Package_SON +X2SON-8_1.4x1mm_P0.35mm +X2SON-8 1.4x1mm Pitch0.35mm http://www.ti.com/lit/ds/symlink/pca9306.pdf +X2SON-8 1.4x1mm Pitch0.35mm +0 +8 +8 +Package_SO_J-Lead +TSOC-6_3.76x3.94mm_P1.27mm +Maxim Integrated TSOC-6 D6+1,https://datasheets.maximintegrated.com/en/ds/DS2401.pdf, https://pdfserv.maximintegrated.com/land_patterns/90-0321.PDF +TSOC-6 +0 +6 +6 +Package_TO_SOT_SMD +ATPAK-2 +ATPAK SMD package, http://www.onsemi.com/pub/Collateral/ENA2192-D.PDF +ATPAK +0 +7 +3 +Package_TO_SOT_SMD +Analog_KS-4 +Analog Devices KS-4, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/sc70ks/ks_4.pdf +Analog Devices KS-4 (like EIAJ SC-82) +0 +4 +4 +Package_TO_SOT_SMD +Diodes_SOT-553 +Diodes SOT-553, https://www.diodes.com/assets/Package-Files/SOT553.pdf +SOT-553 +0 +5 +5 +Package_TO_SOT_SMD +HVSOF5 +HVSOF5, http://rohmfs.rohm.com/en/techdata_basic/ic/package/hvsof5_1-e.pdf, http://rohmfs.rohm.com/en/products/databook/datasheet/ic/sensor/hall/bu52001gul-e.pdf +HVSOF5 +0 +5 +5 +Package_TO_SOT_SMD +HVSOF6 +HVSOF6, http://rohmfs.rohm.com/en/techdata_basic/ic/package/hvsof6_1-e.pdf, http://rohmfs.rohm.com/en/products/databook/datasheet/ic/audio_video/video_amplifier/bh76106hfv-e.pdf +HVSOF6 +0 +7 +7 +Package_TO_SOT_SMD +Infineon_PG-HDSOP-10-1 +Infineon PG-HDSOP-10-1 (DDPAK), 20.96x6.5x2.3mm, slug up (https://www.infineon.com/cms/en/product/packages/PG-HDSOP/PG-HDSOP-10-1/) +hdsop 10 ddpak +0 +10 +10 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-1 +HSOF-8-1 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-1/) +mosfet hsof toll +0 +53 +3 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-1_ThermalVias +HSOF-8-1 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-1/) +mosfet hsof toll thermal vias +0 +96 +3 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-2 +HSOF-8-2 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-2/) +mosfet hsof toll +0 +12 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-2_ThermalVias +HSOF-8-2 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-2/) +mosfet hsof toll thermal vias +0 +97 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-2_ThermalVias2 +HSOF-8-2 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-2/, https://www.infineon.com/dgdl/Infineon-ApplicationNote_600V_CoolMOS_C7_Gold_TOLL-AN-v01_00-EN.pdf?fileId=5546d4625b10283a015b144a1af70df6) +mosfet hsof toll thermal vias +0 +159 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-3 +HSOF-8-3 power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-3/) +mosfet hsof +0 +25 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-3_ThermalVias +HSOF-8-3 power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-3/) +mosfet hsof +0 +64 +4 +Package_TO_SOT_SMD +Infineon_PG-TO-220-7Lead_TabPin8 +Infineon PG-TO-220-7, Tab as Pin 8, see e.g. https://www.infineon.com/dgdl/Infineon-BTS50055-1TMC-DS-v01_00-EN.pdf?fileId=5546d4625a888733015aa9b0007235e9 +Infineon PG-TO-220-7 +0 +12 +8 +Package_TO_SOT_SMD +LFPAK33 +LFPAK33 SOT-1210 https://assets.nexperia.com/documents/outline-drawing/SOT1210.pdf +LFPAK33 SOT-1210 +0 +17 +5 +Package_TO_SOT_SMD +LFPAK56 +LFPAK56 https://assets.nexperia.com/documents/outline-drawing/SOT669.pdf +LFPAK56 SOT-669 Power-SO8 +0 +18 +5 +Package_TO_SOT_SMD +OnSemi_ECH8 +On Semiconductor ECH8, https://www.onsemi.com/pub/Collateral/318BF.PDF +ECH8 SOT28-FL SOT-28-FL +0 +8 +8 +Package_TO_SOT_SMD +PQFN_8x8 +Low Profile 8x8mm PQFN, Dual Cool 88, https://www.onsemi.com/pub/Collateral/FDMT80080DC-D.pdf +pqfn vdfn mosfet +0 +9 +3 +Package_TO_SOT_SMD +PowerMacro_M234_NoHole +TO-50-4 Power Macro Package Style M234 +TO-50-4 Power Macro Package Style M234 +0 +4 +4 +Package_TO_SOT_SMD +PowerMacro_M234_WithHole +TO-50-4 Power Macro Package Style M234 +TO-50-4 Power Macro Package Style M234 +0 +4 +4 +Package_TO_SOT_SMD +Rohm_HRP7 +Rohm HRP7 SMD package, http://rohmfs.rohm.com/en/techdata_basic/ic/package/hrp7_1-e.pdf, http://rohmfs.rohm.com/en/products/databook/datasheet/ic/motor/dc/bd621x-e.pdf +Rohm HRP7 SMD +0 +69 +7 +Package_TO_SOT_SMD +SC-59 +SC-59, https://lib.chipdip.ru/images/import_diod/original/SOT-23_SC-59.jpg +SC-59 +0 +3 +3 +Package_TO_SOT_SMD +SC-59_Handsoldering +SC-59, hand-soldering varaint, https://lib.chipdip.ru/images/import_diod/original/SOT-23_SC-59.jpg +SC-59 hand-soldering +0 +3 +3 +Package_TO_SOT_SMD +SC-70-8 +SC70-8 +SC70-8 +0 +8 +8 +Package_TO_SOT_SMD +SC-70-8_Handsoldering +SC70-8, Handsoldering +SC70-8 Handsoldering +0 +8 +8 +Package_TO_SOT_SMD +SC-82AA +SC-82AA +SC-82AA +0 +4 +4 +Package_TO_SOT_SMD +SC-82AA_Handsoldering +SC-82AA +SC-82AA +0 +4 +4 +Package_TO_SOT_SMD +SC-82AB +SC-82AB +SC-82AB +0 +4 +4 +Package_TO_SOT_SMD +SC-82AB_Handsoldering +SC-82AB +SC-82AB +0 +4 +4 +Package_TO_SOT_SMD +SOT-23 +SOT-23, Standard +SOT-23 +0 +3 +3 +Package_TO_SOT_SMD +SOT-23-5 +5-pin SOT23 package +SOT-23-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-23-5_HandSoldering +5-pin SOT23 package +SOT-23-5 hand-soldering +0 +5 +5 +Package_TO_SOT_SMD +SOT-23-6 +6-pin SOT-23 package +SOT-23-6 +0 +6 +6 +Package_TO_SOT_SMD +SOT-23-6_Handsoldering +6-pin SOT-23 package, Handsoldering +SOT-23-6 Handsoldering +0 +6 +6 +Package_TO_SOT_SMD +SOT-23-8 +8-pin SOT-23 package, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/sot-23rj/rj_8.pdf +SOT-23-8 +0 +8 +8 +Package_TO_SOT_SMD +SOT-23-8_Handsoldering +8-pin SOT-23 package, Handsoldering, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/sot-23rj/rj_8.pdf +SOT-23-8 Handsoldering +0 +8 +8 +Package_TO_SOT_SMD +SOT-23W +SOT-23W http://www.allegromicro.com/~/media/Files/Datasheets/A112x-Datasheet.ashx?la=en&hash=7BC461E058CC246E0BAB62433B2F1ECA104CA9D3 +SOT-23W +0 +3 +3 +Package_TO_SOT_SMD +SOT-23W_Handsoldering +SOT-23W http://www.allegromicro.com/~/media/Files/Datasheets/A112x-Datasheet.ashx?la=en&hash=7BC461E058CC246E0BAB62433B2F1ECA104CA9D3 +SOT-23W for handsoldering +0 +3 +3 +Package_TO_SOT_SMD +SOT-23_Handsoldering +SOT-23, Handsoldering +SOT-23 +0 +3 +3 +Package_TO_SOT_SMD +SOT-89-3 +SOT-89-3, http://ww1.microchip.com/downloads/en/DeviceDoc/3L_SOT-89_MB_C04-029C.pdf +SOT-89-3 +0 +3 +3 +Package_TO_SOT_SMD +SOT-89-3_Handsoldering +SOT-89-3 Handsoldering +SOT-89-3 Handsoldering +0 +3 +3 +Package_TO_SOT_SMD +SOT-89-5 +SOT-89-5, http://www.e-devices.ricoh.co.jp/en/products/product_power/pkg/sot-89-5.pdf +SOT-89-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-89-5_Handsoldering +SOT-89-5, http://www.e-devices.ricoh.co.jp/en/products/product_power/pkg/sot-89-5.pdf +SOT-89-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-143 +SOT-143 +SOT-143 +0 +4 +4 +Package_TO_SOT_SMD +SOT-143R_Reverse +SOT-143R Reverse +SOT-143R Reverse +0 +4 +4 +Package_TO_SOT_SMD +SOT-143R_Reverse_Handsoldering +SOT-143R Reverse Handsoldering +SOT-143 Reverse Handsoldering +0 +4 +4 +Package_TO_SOT_SMD +SOT-143_Handsoldering +SOT-143 Handsoldering +SOT-143 Handsoldering +0 +4 +4 +Package_TO_SOT_SMD +SOT-223 +module CMS SOT223 4 pins +CMS SOT +0 +4 +4 +Package_TO_SOT_SMD +SOT-223-3_TabPin2 +module CMS SOT223 4 pins +CMS SOT +0 +4 +3 +Package_TO_SOT_SMD +SOT-223-5 +module CMS SOT223 5 pins, http://ww1.microchip.com/downloads/en/DeviceDoc/51751a.pdf +CMS SOT +0 +5 +5 +Package_TO_SOT_SMD +SOT-223-6 +module CMS SOT223 6 pins, http://www.ti.com/lit/ds/symlink/tps737.pdf +CMS SOT +0 +6 +6 +Package_TO_SOT_SMD +SOT-223-6_TabPin3 +module CMS SOT223 6 pins, http://www.ti.com/lit/ds/symlink/tps737.pdf +CMS SOT +0 +6 +5 +Package_TO_SOT_SMD +SOT-223-8 +module CMS SOT223 8 pins, https://www.diodes.com/assets/Datasheets/ZXSBMR16PT8.pdf +CMS SOT +0 +8 +8 +Package_TO_SOT_SMD +SOT-323_SC-70 +SOT-323, SC-70 +SOT-323 SC-70 +0 +3 +3 +Package_TO_SOT_SMD +SOT-323_SC-70_Handsoldering +SOT-323, SC-70 Handsoldering +SOT-323 SC-70 Handsoldering +0 +3 +3 +Package_TO_SOT_SMD +SOT-343_SC-70-4 +SOT-343, SC-70-4 +SOT-343 SC-70-4 +0 +4 +4 +Package_TO_SOT_SMD +SOT-343_SC-70-4_Handsoldering +SOT-343, SC-70-4, Handsoldering +SOT-343 SC-70-4 Handsoldering +0 +4 +4 +Package_TO_SOT_SMD +SOT-353_SC-70-5 +SOT-353, SC-70-5 +SOT-353 SC-70-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-353_SC-70-5_Handsoldering +SOT-353, SC-70-5, Handsoldering +SOT-353 SC-70-5 Handsoldering +0 +5 +5 +Package_TO_SOT_SMD +SOT-363_SC-70-6 +SOT-363, SC-70-6 +SOT-363 SC-70-6 +0 +6 +6 +Package_TO_SOT_SMD +SOT-363_SC-70-6_Handsoldering +SOT-363, SC-70-6, Handsoldering +SOT-363 SC-70-6 Handsoldering +0 +6 +6 +Package_TO_SOT_SMD +SOT-383F +8-pin SOT-383F, http://www.mouser.com/ds/2/80/CPDVR085V0C-HF-RevB-10783.pdf +SOT-383F +0 +9 +9 +Package_TO_SOT_SMD +SOT-383FL +8-pin SOT-383FL package, http://www.onsemi.com/pub_link/Collateral/ENA2267-D.PDF +SOT-383FL +0 +8 +8 +Package_TO_SOT_SMD +SOT-416 +SOT-416, https://www.nxp.com/docs/en/package-information/SOT416.pdf +SOT-416 +0 +3 +3 +Package_TO_SOT_SMD +SOT-523 +SOT523, https://www.diodes.com/assets/Package-Files/SOT523.pdf +SOT-523 +0 +3 +3 +Package_TO_SOT_SMD +SOT-543 +SOT-543 4 lead surface package +SOT-543 SC-107A EMD4 +0 +4 +4 +Package_TO_SOT_SMD +SOT-553 +SOT553 +SOT-553 +0 +5 +5 +Package_TO_SOT_SMD +SOT-563 +SOT563 +SOT-563 +0 +6 +6 +Package_TO_SOT_SMD +SOT-665 +SOT665 +SOT-665 +0 +5 +5 +Package_TO_SOT_SMD +SOT-666 +SOT666 +SOT-666 +0 +6 +6 +Package_TO_SOT_SMD +SOT-723 +http://toshiba.semicon-storage.com/info/docget.jsp?did=5879&prodName=RN1104MFV +sot 723 +0 +3 +3 +Package_TO_SOT_SMD +SOT-883 +SOT-883, https://assets.nexperia.com/documents/outline-drawing/SOT883.pdf +SOT-883 +0 +3 +3 +Package_TO_SOT_SMD +SOT-886 +SOT-886 +SOT-886 +0 +6 +6 +Package_TO_SOT_SMD +SOT-963 +SOT 963 6 pins package 1x0.8mm pitch 0.35mm +SOT 963 6 pins package 1x0.8mm pitch 0.35mm +0 +6 +6 +Package_TO_SOT_SMD +SOT-1123 +SOT-1123 small outline transistor (see http://www.onsemi.com/pub/Collateral/NST3906F3-D.PDF) +SOT-1123 transistor +0 +3 +3 +Package_TO_SOT_SMD +SOT-1333-1 +SOT-1333-1 +SOT-1333-1 +0 +9 +9 +Package_TO_SOT_SMD +SOT-1334-1 +SOT-1334-1 +SOT-1334-1 +0 +14 +14 +Package_TO_SOT_SMD +SuperSOT-3 +3-pin SuperSOT package https://www.fairchildsemi.com/package-drawings/MA/MA03B.pdf +SuperSOT-3 SSOT-3 +0 +3 +3 +Package_TO_SOT_SMD +SuperSOT-6 +6-pin SuperSOT package http://www.mouser.com/ds/2/149/FMB5551-889214.pdf +SuperSOT-6 SSOT-6 +0 +6 +6 +Package_TO_SOT_SMD +SuperSOT-8 +8-pin SuperSOT package, http://www.icbank.com/icbank_data/semi_package/ssot8_dim.pdf +SuperSOT-8 SSOT-8 +0 +8 +8 +Package_TO_SOT_SMD +TDSON-8-1 +Power MOSFET package, TDSON-8-1, 5.15x5.9mm (https://www.infineon.com/cms/en/product/packages/PG-TDSON/PG-TDSON-8-1/) +tdson +0 +14 +5 +Package_TO_SOT_SMD +TO-50-3_LongPad-NoHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-3_LongPad-WithHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-3_ShortPad-NoHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-3_ShortPad-WithHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-4_LongPad-NoHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-50-4_LongPad-WithHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-50-4_ShortPad-NoHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-50-4_ShortPad-WithHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-252-2 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-3-1/ +DPAK TO-252 DPAK-3 TO-252-3 SOT-428 +0 +7 +3 +Package_TO_SOT_SMD +TO-252-2_TabPin1 +TO-252-2, tab to pin 1 https://www.wolfspeed.com/media/downloads/87/CSD01060.pdf +TO-252-2 diode +0 +7 +2 +Package_TO_SOT_SMD +TO-252-3_TabPin2 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-3-1/ +DPAK TO-252 DPAK-3 TO-252-3 SOT-428 +0 +8 +3 +Package_TO_SOT_SMD +TO-252-3_TabPin4 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-3-1/ +DPAK TO-252 DPAK-3 TO-252-3 SOT-428 +0 +8 +4 +Package_TO_SOT_SMD +TO-252-4 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-5-11/ +DPAK TO-252 DPAK-5 TO-252-5 +0 +9 +5 +Package_TO_SOT_SMD +TO-252-5_TabPin3 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-5-11/ +DPAK TO-252 DPAK-5 TO-252-5 +0 +10 +5 +Package_TO_SOT_SMD +TO-252-5_TabPin6 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-5-11/ +DPAK TO-252 DPAK-5 TO-252-5 +0 +10 +6 +Package_TO_SOT_SMD +TO-263-2 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-3-1/ +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 +0 +7 +3 +Package_TO_SOT_SMD +TO-263-2_TabPin1 +TO-263 / D2PAK / DDPAK SMD package, tab to pin 1, https://www.wolfspeed.com/media/downloads/137/C3D06060G.pdf +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 diode +0 +7 +2 +Package_TO_SOT_SMD +TO-263-3_TabPin2 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-3-1/ +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 +0 +8 +3 +Package_TO_SOT_SMD +TO-263-3_TabPin4 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-3-1/ +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 +0 +8 +4 +Package_TO_SOT_SMD +TO-263-4 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-5-1/ +D2PAK DDPAK TO-263 D2PAK-5 TO-263-5 SOT-426 +0 +9 +5 +Package_TO_SOT_SMD +TO-263-5_TabPin3 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-5-1/ +D2PAK DDPAK TO-263 D2PAK-5 TO-263-5 SOT-426 +0 +10 +5 +Package_TO_SOT_SMD +TO-263-5_TabPin6 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-5-1/ +D2PAK DDPAK TO-263 D2PAK-5 TO-263-5 SOT-426 +0 +10 +6 +Package_TO_SOT_SMD +TO-263-6 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-7-1/ +D2PAK DDPAK TO-263 D2PAK-7 TO-263-7 SOT-427 +0 +11 +7 +Package_TO_SOT_SMD +TO-263-7_TabPin4 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-7-1/ +D2PAK DDPAK TO-263 D2PAK-7 TO-263-7 SOT-427 +0 +12 +7 +Package_TO_SOT_SMD +TO-263-7_TabPin8 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-7-1/ +D2PAK DDPAK TO-263 D2PAK-7 TO-263-7 SOT-427 +0 +12 +8 +Package_TO_SOT_SMD +TO-263-9_TabPin5 +TO-263 / D2PAK / DDPAK SMD package, http://www.ti.com/lit/ds/symlink/lm4755.pdf +D2PAK DDPAK TO-263 D2PAK-9 TO-263-9 +0 +14 +9 +Package_TO_SOT_SMD +TO-263-9_TabPin10 +TO-263 / D2PAK / DDPAK SMD package, http://www.ti.com/lit/ds/symlink/lm4755.pdf +D2PAK DDPAK TO-263 D2PAK-9 TO-263-9 +0 +14 +10 +Package_TO_SOT_SMD +TO-268-2 +TO-268/D3PAK SMD package, http://www.icbank.com/icbank_data/semi_package/to268aa_dim.pdf +D3PAK TO-268 D3PAK-3 TO-268-3 +0 +7 +3 +Package_TO_SOT_SMD +TO-269AA +SMD package TO-269AA (e.g. diode bridge), see http://www.vishay.com/docs/88854/padlayouts.pdf +TO-269AA MBS diode bridge +0 +4 +4 +Package_TO_SOT_SMD +TO-277A +Thermal enhanced ultra thin SMD package; 3 leads; body: 4.3x6.1x0.43mm, https://www.vishay.com/docs/95570/to-277asmpc.pdf +TO-277A SMPC +0 +12 +3 +Package_TO_SOT_SMD +TO-277B +TO-227B https://media.digikey.com/pdf/Data%20Sheets/Littelfuse%20PDFs/DST2050S.pdf +TO-277B +0 +9 +3 +Package_TO_SOT_SMD +TSOT-23 +3-pin TSOT23 package, http://www.analog.com.tw/pdf/All_In_One.pdf +TSOT-23 +0 +3 +3 +Package_TO_SOT_SMD +TSOT-23-5 +5-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_5_05-08-1635.pdf +TSOT-23-5 +0 +5 +5 +Package_TO_SOT_SMD +TSOT-23-5_HandSoldering +5-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_5_05-08-1635.pdf +TSOT-23-5 Hand-soldering +0 +5 +5 +Package_TO_SOT_SMD +TSOT-23-6 +6-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_6_05-08-1636.pdf +TSOT-23-6 MK06A TSOT-6 +0 +6 +6 +Package_TO_SOT_SMD +TSOT-23-6_HandSoldering +6-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_6_05-08-1636.pdf +TSOT-23-6 MK06A TSOT-6 Hand-soldering +0 +6 +6 +Package_TO_SOT_SMD +TSOT-23-8 +8-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_8_05-08-1637.pdf +TSOT-23-8 +0 +8 +8 +Package_TO_SOT_SMD +TSOT-23-8_HandSoldering +8-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_8_05-08-1637.pdf +TSOT-23-8 Hand-soldering +0 +8 +8 +Package_TO_SOT_SMD +TSOT-23_HandSoldering +5-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_5_05-08-1635.pdf +TSOT-23 Hand-soldering +0 +3 +3 +Package_TO_SOT_SMD +Texas_DRT-3 +Texas Instrument DRT-3 1x0.8mm Pitch 0.7mm http://www.ti.com/lit/ds/symlink/tpd2eusb30.pdf +DRT-3 1x0.8mm Pitch 0.7mm +0 +3 +3 +Package_TO_SOT_SMD +Texas_NDQ +Texas Instruments, NDQ, 5 pin (https://www.ti.com/lit/ml/mmsf022/mmsf022.pdf) +ti pfm dap +0 +6 +6 +Package_TO_SOT_SMD +Texas_NDY0011A +TO-PMOD-11 11-pin switching regulator package, http://www.ti.com/lit/ml/mmsf025/mmsf025.pdf +Texas TO-PMOD NDY00011A +0 +12 +12 +Package_TO_SOT_SMD +Texas_R-PDSO-G6 +R-PDSO-G6, http://www.ti.com/lit/ds/slis144b/slis144b.pdf +R-PDSO-G6 SC-70-6 +0 +6 +6 +Package_TO_SOT_SMD +VSOF5 +VSOF5 +VSOF5 +0 +5 +5 +Package_TO_SOT_SMD +Vishay_PowerPAK_SC70-6L_Dual +Vishay PowerPAK SC70 dual transistor package http://www.vishay.com/docs/70487/70487.pdf +powerpak sc70 sc-70 dual +0 +8 +6 +Package_TO_SOT_SMD +Vishay_PowerPAK_SC70-6L_Single +Vishay PowerPAK SC70 single transistor package http://www.vishay.com/docs/70486/70486.pdf +powerpak sc70 sc-70 +0 +6 +3 +Package_TO_SOT_THT +Fairchild_TO-220F-6L +Fairchild TO-220F-6L, http://www.mouser.com/ds/2/149/FSL136MRT-113334.pdf +Fairchild TO-220F-6L +0 +6 +6 +Package_TO_SOT_THT +Heraeus_TO-92-2 +TO-92 2-pin variant by Heraeus, drill 0.75mm (http://www.produktinfo.conrad.com/datenblaetter/175000-199999/181293-da-01-de-TO92_Temperatursensor_PT1000_32209225.pdf) +to-92 +0 +2 +2 +Package_TO_SOT_THT +NEC_Molded_7x4x9mm +Molded Japan Transistor Package 7x4x9mm^3, http://rtellason.com/transdata/2sb734.pdf +Japan transistor +0 +3 +3 +Package_TO_SOT_THT +PowerIntegrations_TO-220-7C +Non Isolated Modified TO-220 7pin Package, see http://www.farnell.com/datasheets/5793.pdf +Power Integration Y Package +0 +6 +6 +Package_TO_SOT_THT +SIPAK-1EP_Horizontal_TabDown +SIPAK, Horizontal, RM 2.286mm +SIPAK Horizontal RM 2.286mm +0 +4 +4 +Package_TO_SOT_THT +SIPAK_Vertical +SIPAK, Vertical, RM 2.286mm +SIPAK Vertical RM 2.286mm +0 +3 +3 +Package_TO_SOT_THT +SOD-70_P2.54mm +Plastic near cylindrical package Sod-70 see: https://www.nxp.com/docs/en/data-sheet/KTY81_SER.pdf [StepUp generated footprint] +Sod-70 +0 +2 +2 +Package_TO_SOT_THT +SOD-70_P5.08mm +Plastic near cylindrical package Sod-70 see: https://www.nxp.com/docs/en/data-sheet/KTY81_SER.pdf [StepUp generated footprint] +Sod-70 +0 +2 +2 +Package_TO_SOT_THT +SOT-227 +SOT-227 / SOT-227B / ISOTOP, M4 mounting screws (https://www.vishay.com/docs/95423/sot227g2.pdf, https://www.vishay.com/docs/95793/vs-fc420sa10.pdf) +sot 227 isotop +0 +8 +4 +Package_TO_SOT_THT +TO-3 +Transistor TO-3 +TR TO-3 TO3 TO-204 +0 +4 +3 +Package_TO_SOT_THT +TO-3P-3_Horizontal_TabDown +TO-3P-3, Horizontal, RM 5.45mm, , see https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.TO-3P(N).html +TO-3P-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3P-3_Horizontal_TabUp +TO-3P-3, Horizontal, RM 5.45mm, , see https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.TO-3P(N).html +TO-3P-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3P-3_Vertical +TO-3P-3, Vertical, RM 5.45mm, , see https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.TO-3P(N).html +TO-3P-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3PB-3_Horizontal_TabDown +TO-3PB-3, Horizontal, RM 5.45mm, , see http://www.onsemi.com/pub/Collateral/340AC.PDF +TO-3PB-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3PB-3_Horizontal_TabUp +TO-3PB-3, Horizontal, RM 5.45mm, , see http://www.onsemi.com/pub/Collateral/340AC.PDF +TO-3PB-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3PB-3_Vertical +TO-3PB-3, Vertical, RM 5.45mm, , see http://www.onsemi.com/pub/Collateral/340AC.PDF +TO-3PB-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-5-2 +TO-5-2 +TO-5-2 +0 +2 +2 +Package_TO_SOT_THT +TO-5-2_Window +TO-5-2_Window, Window +TO-5-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-5-3 +TO-5-3 +TO-5-3 +0 +3 +3 +Package_TO_SOT_THT +TO-5-3_Window +TO-5-3_Window, Window +TO-5-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-5-4 +TO-5-4 +TO-5-4 +0 +4 +4 +Package_TO_SOT_THT +TO-5-4_Window +TO-5-4_Window, Window +TO-5-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-5-6 +TO-5-6 +TO-5-6 +0 +6 +6 +Package_TO_SOT_THT +TO-5-6_Window +TO-5-6_Window, Window +TO-5-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-5-8 +TO-5-8 +TO-5-8 +0 +8 +8 +Package_TO_SOT_THT +TO-5-8_PD5.08 +TO-5-8_PD5.08 +TO-5-8_PD5.08 +0 +8 +8 +Package_TO_SOT_THT +TO-5-8_PD5.08_Window +TO-5-8_PD5.08_Window, Window +TO-5-8_PD5.08_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-5-8_Window +TO-5-8_Window, Window +TO-5-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-5-10 +TO-5-10 +TO-5-10 +0 +10 +10 +Package_TO_SOT_THT +TO-5-10_Window +TO-5-10_Window, Window +TO-5-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-8-2 +TO-8-2 +TO-8-2 +0 +2 +2 +Package_TO_SOT_THT +TO-8-2_Window +TO-8-2_Window, Window +TO-8-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-8-3 +TO-8-3 +TO-8-3 +0 +3 +3 +Package_TO_SOT_THT +TO-8-3_Window +TO-8-3_Window, Window +TO-8-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-11-2 +TO-11-2 +TO-11-2 +0 +2 +2 +Package_TO_SOT_THT +TO-11-2_Window +TO-11-2_Window, Window +TO-11-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-11-3 +TO-11-3 +TO-11-3 +0 +3 +3 +Package_TO_SOT_THT +TO-11-3_Window +TO-11-3_Window, Window +TO-11-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-12-4 +TO-12-4 +TO-12-4 +0 +4 +4 +Package_TO_SOT_THT +TO-12-4_Window +TO-12-4_Window, Window +TO-12-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-17-4 +TO-17-4 +TO-17-4 +0 +4 +4 +Package_TO_SOT_THT +TO-17-4_Window +TO-17-4_Window, Window +TO-17-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-18-2 +TO-18-2 +TO-18-2 +0 +2 +2 +Package_TO_SOT_THT +TO-18-2_Lens +TO-18-2_Lens, Lens +TO-18-2_Lens Lens +0 +2 +2 +Package_TO_SOT_THT +TO-18-2_Window +TO-18-2_Window, Window +TO-18-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-18-3 +TO-18-3 +TO-18-3 +0 +3 +3 +Package_TO_SOT_THT +TO-18-3_Lens +TO-18-3_Lens, Lens +TO-18-3_Lens Lens +0 +3 +3 +Package_TO_SOT_THT +TO-18-3_Window +TO-18-3_Window, Window +TO-18-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-18-4 +TO-18-4 +TO-18-4 +0 +4 +4 +Package_TO_SOT_THT +TO-18-4_Lens +TO-18-4_Lens, Lens +TO-18-4_Lens Lens +0 +4 +4 +Package_TO_SOT_THT +TO-18-4_Window +TO-18-4_Window, Window +TO-18-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-33-4 +TO-33-4 +TO-33-4 +0 +4 +4 +Package_TO_SOT_THT +TO-33-4_Window +TO-33-4_Window, Window +TO-33-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-38-2 +TO-38-2 +TO-38-2 +0 +2 +2 +Package_TO_SOT_THT +TO-38-2_Window +TO-38-2_Window, Window +TO-38-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-38-3 +TO-38-3 +TO-38-3 +0 +3 +3 +Package_TO_SOT_THT +TO-38-3_Window +TO-38-3_Window, Window +TO-38-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-39-2 +TO-39-2 +TO-39-2 +0 +2 +2 +Package_TO_SOT_THT +TO-39-2_Window +TO-39-2_Window, Window +TO-39-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-39-3 +TO-39-3 +TO-39-3 +0 +3 +3 +Package_TO_SOT_THT +TO-39-3_Window +TO-39-3_Window, Window +TO-39-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-39-4 +TO-39-4 +TO-39-4 +0 +4 +4 +Package_TO_SOT_THT +TO-39-4_Window +TO-39-4_Window, Window +TO-39-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-39-6 +TO-39-6 +TO-39-6 +0 +6 +6 +Package_TO_SOT_THT +TO-39-6_Window +TO-39-6_Window, Window +TO-39-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-39-8 +TO-39-8 +TO-39-8 +0 +8 +8 +Package_TO_SOT_THT +TO-39-8_Window +TO-39-8_Window, Window +TO-39-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-39-10 +TO-39-10 +TO-39-10 +0 +10 +10 +Package_TO_SOT_THT +TO-39-10_Window +TO-39-10_Window, Window +TO-39-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-46-2 +TO-46-2 +TO-46-2 +0 +2 +2 +Package_TO_SOT_THT +TO-46-2_Pin2Center +TO-46-2, Pin2 at center of package, Thorlabs photodiodes +TO-46-2 Thorlabs +0 +2 +2 +Package_TO_SOT_THT +TO-46-2_Pin2Center_Window +TO-46-2, Pin2 at center of package, Thorlabs photodiodes +TO-46-2 Thorlabs +0 +2 +2 +Package_TO_SOT_THT +TO-46-2_Window +TO-46-2_Window, Window +TO-46-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-46-3 +TO-46-3 +TO-46-3 +0 +3 +3 +Package_TO_SOT_THT +TO-46-3_Pin2Center +TO-46-3, Pin2 at center of package, Thorlabs photodiodes, https://www.thorlabs.de/drawings/374b6862eb3b5a04-9360B5F6-5056-2306-D912111C06C3F830/FDGA05-SpecSheet.pdf +TO-46-3 Thorlabs +0 +3 +3 +Package_TO_SOT_THT +TO-46-3_Pin2Center_Window +TO-46-3, Pin2 at center of package, Thorlabs photodiodes, https://www.thorlabs.de/drawings/374b6862eb3b5a04-9360B5F6-5056-2306-D912111C06C3F830/FDGA05-SpecSheet.pdf +TO-46-3 Thorlabs +0 +3 +3 +Package_TO_SOT_THT +TO-46-3_Window +TO-46-3_Window, Window +TO-46-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-46-4 +TO-46-4 +TO-46-4 +0 +4 +4 +Package_TO_SOT_THT +TO-46-4_Window +TO-46-4_Window, Window +TO-46-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-52-2 +TO-52-2 +TO-52-2 +0 +2 +2 +Package_TO_SOT_THT +TO-52-2_Window +TO-52-2_Window, Window +TO-52-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-52-3 +TO-52-3 +TO-52-3 +0 +3 +3 +Package_TO_SOT_THT +TO-52-3_Window +TO-52-3_Window, Window +TO-52-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-72-4 +TO-72-4 +TO-72-4 +0 +4 +4 +Package_TO_SOT_THT +TO-72-4_Window +TO-72-4_Window, Window +TO-72-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-75-6 +TO-75-6 +TO-75-6 +0 +6 +6 +Package_TO_SOT_THT +TO-75-6_Window +TO-75-6_Window, Window +TO-75-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-78-6 +TO-78-6 +TO-78-6 +0 +6 +6 +Package_TO_SOT_THT +TO-78-6_Window +TO-78-6_Window, Window +TO-78-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-78-8 +TO-78-8 +TO-78-8 +0 +8 +8 +Package_TO_SOT_THT +TO-78-8_Window +TO-78-8_Window, Window +TO-78-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-78-10 +TO-78-10 +TO-78-10 +0 +10 +10 +Package_TO_SOT_THT +TO-78-10_Window +TO-78-10_Window, Window +TO-78-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-92 +TO-92 leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92-2 +TO-92 2-pin leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 diode SOD70 +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_Horizontal1 +2-pin TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 temperature sensor diode +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_Horizontal2 +2-pin TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 temperature sensor diode +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_W4.0mm_Horizontal_FlatSideDown +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_W4.0mm_Horizontal_FlatSideUp +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_Wide +TO-92 2-pin leads in-line, wide, drill 0.75mm +to-92 sc-43 sc-43a sot54 PA33 diode SOD70 +0 +2 +2 +Package_TO_SOT_THT +TO-92Flat +TO-92Flat package, often used for hall sensors, drill 0.75mm (see e.g. http://www.ti.com/lit/ds/symlink/drv5023.pdf) +to-92Flat hall sensor +0 +3 +3 +Package_TO_SOT_THT +TO-92L +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Molded Narrow transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_HandSolder +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm, hand-soldering variant with enlarged pads (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_Inline +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Inline Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_Inline_Wide +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Inline Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_Wide +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Molded Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92Mini-2 +TO-92Mini package, drill 0.6mm (https://media.digikey.com/pdf/Data%20Sheets/Infineon%20PDFs/KT,KTY.pdf) +to-92Mini transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92S +TO-92S package, drill 0.75mm (https://www.diodes.com/assets/Package-Files/TO92S%20(Type%20B).pdf) +to-92S transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92S-2 +TO-92S package, 2-pin, drill 0.75mm (https://www.diodes.com/assets/Package-Files/TO92S%20(Type%20B).pdf) +to-92S transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92S_Wide +TO-92S_Wide package, drill 0.75mm (https://www.diodes.com/assets/Package-Files/TO92S%20(Type%20B).pdf) +TO-92S_Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_HandSolder +TO-92 leads molded, narrow, drill 0.75mm, handsoldering variant with enlarged pads (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Horizontal1 +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Horizontal2 +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline +TO-92 leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_Horizontal1 +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_Horizontal2 +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_W4.0mm_Horizontal_FlatSideDown +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_W4.0mm_Horizontal_FlatSideUp +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_Wide +TO-92 leads in-line, wide, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_W4.0mm_StaggerEven_Horizontal_FlatSideDown +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_W4.0mm_StaggerEven_Horizontal_FlatSideUp +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Wide +TO-92 leads molded, wide, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-99-6 +TO-99-6 +TO-99-6 +0 +6 +6 +Package_TO_SOT_THT +TO-99-6_Window +TO-99-6_Window, Window +TO-99-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-99-8 +TO-99-8 +TO-99-8 +0 +8 +8 +Package_TO_SOT_THT +TO-99-8_Window +TO-99-8_Window, Window +TO-99-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-100-10 +TO-100-10 +TO-100-10 +0 +10 +10 +Package_TO_SOT_THT +TO-100-10_Window +TO-100-10_Window, Window +TO-100-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-126-2_Horizontal_TabDown +TO-126-2, Horizontal, RM 5.08mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-126-2_Horizontal_TabUp +TO-126-2, Horizontal, RM 5.08mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-126-2_Vertical +TO-126-2, Vertical, RM 5.08mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-2 Vertical RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-126-3_Horizontal_TabDown +TO-126-3, Horizontal, RM 2.54mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-126-3_Horizontal_TabUp +TO-126-3, Horizontal, RM 2.54mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-126-3_Vertical +TO-126-3, Vertical, RM 2.54mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-3 Vertical RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-218-2_Horizontal_TabDown +TO-218-2, Horizontal, RM 10.95mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-2 Horizontal RM 10.95mm SOT-93 +0 +2 +2 +Package_TO_SOT_THT +TO-218-2_Horizontal_TabUp +TO-218-2, Horizontal, RM 10.95mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-2 Horizontal RM 10.95mm SOT-93 +0 +2 +2 +Package_TO_SOT_THT +TO-218-2_Vertical +TO-218-2, Vertical, RM 10.95mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-2 Vertical RM 10.95mm SOT-93 +0 +2 +2 +Package_TO_SOT_THT +TO-218-3_Horizontal_TabDown +TO-218-3, Horizontal, RM 5.475mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-3 Horizontal RM 5.475mm SOT-93 +0 +3 +3 +Package_TO_SOT_THT +TO-218-3_Horizontal_TabUp +TO-218-3, Horizontal, RM 5.475mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-3 Horizontal RM 5.475mm SOT-93 +0 +3 +3 +Package_TO_SOT_THT +TO-218-3_Vertical +TO-218-3, Vertical, RM 5.475mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-3 Vertical RM 5.475mm SOT-93 +0 +3 +3 +Package_TO_SOT_THT +TO-220-2_Horizontal_TabDown +TO-220-2, Horizontal, RM 5.08mm, see https://www.centralsemi.com/PDFS/CASE/TO-220-2PD.PDF +TO-220-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220-2_Horizontal_TabUp +TO-220-2, Horizontal, RM 5.08mm, see https://www.centralsemi.com/PDFS/CASE/TO-220-2PD.PDF +TO-220-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220-2_Vertical +TO-220-2, Vertical, RM 5.08mm, see https://www.centralsemi.com/PDFS/CASE/TO-220-2PD.PDF +TO-220-2 Vertical RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220-3_Horizontal_TabDown +TO-220-3, Horizontal, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf +TO-220-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220-3_Horizontal_TabUp +TO-220-3, Horizontal, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf +TO-220-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220-3_Vertical +TO-220-3, Vertical, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf +TO-220-3 Vertical RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220-4_Horizontal_TabDown +TO-220-4, Horizontal, RM 2.54mm +TO-220-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_Horizontal_TabUp +TO-220-4, Horizontal, RM 2.54mm +TO-220-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerEven_Lead3.8mm_Vertical +TO-220-4, Vertical, RM 2.54mm, staggered type-2 +TO-220-4 Vertical RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerEven_Lead5.84mm_TabDown +TO-220-4, Horizontal, RM 2.54mm, staggered type-2 +TO-220-4 Horizontal RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-4, Vertical, RM 2.54mm, staggered type-1 +TO-220-4 Vertical RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerOdd_Lead5.84mm_TabDown +TO-220-4, Horizontal, RM 2.54mm, staggered type-1 +TO-220-4 Horizontal RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_Vertical +TO-220-4, Vertical, RM 2.54mm +TO-220-4 Vertical RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220-5_Horizontal_TabDown +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421_straight_lead.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_Horizontal_TabUp +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421_straight_lead.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.7mm_StaggerEven_Lead3.8mm_Vertical +TO-220-5, Vertical, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-2, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Vertical RM 1.7mm Pentawatt Multiwatt-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.7mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-5, Vertical, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-1, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Vertical RM 1.7mm Pentawatt Multiwatt-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.8mm_StaggerEven_Lead7.13mm_TabDown +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-2, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.8mm_StaggerOdd_Lead7.13mm_TabDown +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-1, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_Vertical +TO-220-5, Vertical, RM 1.7mm, Pentawatt, Multiwatt-5, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421_straight_lead.pdf +TO-220-5 Vertical RM 1.7mm Pentawatt Multiwatt-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220-7_P2.54x3.7mm_StaggerEven_Lead3.8mm_Vertical +TO-220-7, Vertical, RM 1.27mm, Multiwatt-7, staggered type-2 +TO-220-7 Vertical RM 1.27mm Multiwatt-7 staggered type-2 +0 +7 +7 +Package_TO_SOT_THT +TO-220-7_P2.54x3.7mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-7, Vertical, RM 1.27mm, Multiwatt-7, staggered type-1 +TO-220-7 Vertical RM 1.27mm Multiwatt-7 staggered type-1 +0 +7 +7 +Package_TO_SOT_THT +TO-220-7_P2.54x3.8mm_StaggerEven_Lead5.85mm_TabDown +TO-220-7, Horizontal, RM 1.27mm, Multiwatt-7, staggered type-2 +TO-220-7 Horizontal RM 1.27mm Multiwatt-7 staggered type-2 +0 +7 +7 +Package_TO_SOT_THT +TO-220-7_P2.54x3.8mm_StaggerOdd_Lead5.85mm_TabDown +TO-220-7, Horizontal, RM 1.27mm, Multiwatt-7, staggered type-1 +TO-220-7 Horizontal RM 1.27mm Multiwatt-7 staggered type-1 +0 +7 +7 +Package_TO_SOT_THT +TO-220-8_Vertical +TO-220-8 (Multiwatt8), Vertical, 2.54mm Pitch (http://www.st.com/resource/en/datasheet/tda7264.pdf) +TO-220-9 Vertical 2.54mm Pitch Multiwatt 8 +0 +8 +8 +Package_TO_SOT_THT +TO-220-9_P1.94x3.7mm_StaggerEven_Lead3.8mm_Vertical +TO-220-9, Vertical, RM 0.97mm, Multiwatt-9, staggered type-2 +TO-220-9 Vertical RM 0.97mm Multiwatt-9 staggered type-2 +0 +9 +9 +Package_TO_SOT_THT +TO-220-9_P1.94x3.7mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-9, Vertical, RM 0.97mm, Multiwatt-9, staggered type-1 +TO-220-9 Vertical RM 0.97mm Multiwatt-9 staggered type-1 +0 +9 +9 +Package_TO_SOT_THT +TO-220-9_P1.94x3.8mm_StaggerEven_Lead5.85mm_TabDown +TO-220-9, Horizontal, RM 0.97mm, Multiwatt-9, staggered type-2 +TO-220-9 Horizontal RM 0.97mm Multiwatt-9 staggered type-2 +0 +9 +9 +Package_TO_SOT_THT +TO-220-9_P1.94x3.8mm_StaggerOdd_Lead5.85mm_TabDown +TO-220-9, Horizontal, RM 0.97mm, Multiwatt-9, staggered type-1 +TO-220-9 Horizontal RM 0.97mm Multiwatt-9 staggered type-1 +0 +9 +9 +Package_TO_SOT_THT +TO-220-11_P3.4x2.54mm_StaggerEven_Lead5.84mm_TabDown +TO-220-11, Horizontal, RM 1.7mm, staggered type-2, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Horizontal RM 1.7mm staggered type-2 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x2.54mm_StaggerOdd_Lead5.84mm_TabDown +TO-220-11, Horizontal, RM 1.7mm, staggered type-1, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Horizontal RM 1.7mm staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x5.08mm_StaggerEven_Lead4.58mm_Vertical +TO-220-11, Vertical, RM 1.7mm, staggered type-2, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Vertical RM 1.7mm staggered type-2 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x5.08mm_StaggerOdd_Lead4.85mm_Vertical +TO-220-11, Vertical, RM 1.7mm, staggered type-1, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Vertical RM 1.7mm staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x5.08mm_StaggerOdd_Lead8.45mm_TabDown +TO-220-11, Horizontal, RM 1.7mm, staggered type-1, see http://www.ti.com/lit/ds/symlink/lmd18200.pdf +TO-220-11 Horizontal RM 1.7mm staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerEven_Lead4.58mm_Vertical +TO-220-15, Vertical, RM 1.27mm, staggered type-2, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Vertical RM 1.27mm staggered type-2 +0 +15 +15 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerEven_Lead5.84mm_TabDown +TO-220-15, Horizontal, RM 1.27mm, staggered type-2, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Horizontal RM 1.27mm staggered type-2 +0 +15 +15 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerOdd_Lead4.58mm_Vertical +TO-220-15, Vertical, RM 1.27mm, staggered type-1, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Vertical RM 1.27mm staggered type-1 +0 +15 +15 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerOdd_Lead5.84mm_TabDown +TO-220-15, Horizontal, RM 1.27mm, staggered type-1, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Horizontal RM 1.27mm staggered type-1 +0 +15 +15 +Package_TO_SOT_THT +TO-220F-2_Horizontal_TabDown +TO-220F-2, Horizontal, RM 5.08mm, see http://www.onsemi.com/pub/Collateral/FFPF10F150S-D.pdf +TO-220F-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220F-2_Horizontal_TabUp +TO-220F-2, Horizontal, RM 5.08mm, see http://www.onsemi.com/pub/Collateral/FFPF10F150S-D.pdf +TO-220F-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220F-2_Vertical +TO-220F-2, Vertical, RM 5.08mm, see http://www.onsemi.com/pub/Collateral/FFPF10F150S-D.pdf +TO-220F-2 Vertical RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220F-3_Horizontal_TabDown +TO-220F-3, Horizontal, RM 2.54mm, see http://www.st.com/resource/en/datasheet/stp20nm60.pdf +TO-220F-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220F-3_Horizontal_TabUp +TO-220F-3, Horizontal, RM 2.54mm, see http://www.st.com/resource/en/datasheet/stp20nm60.pdf +TO-220F-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220F-3_Vertical +TO-220F-3, Vertical, RM 2.54mm, see http://www.st.com/resource/en/datasheet/stp20nm60.pdf +TO-220F-3 Vertical RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220F-4_Horizontal_TabDown +TO-220F-4, Horizontal, RM 2.54mm, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_Horizontal_TabUp +TO-220F-4, Horizontal, RM 2.54mm, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x2.05mm_StaggerEven_Lead1.85mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-2, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x2.05mm_StaggerOdd_Lead1.85mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-1, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-2, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-1, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_Vertical +TO-220F-4, Vertical, RM 2.54mm, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220F-5_Horizontal_TabDown +TO-220F-5, Horizontal, RM 1.7mm, PentawattF-, MultiwattF-5 +TO-220F-5 Horizontal RM 1.7mm PentawattF- MultiwattF-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_Horizontal_TabUp +TO-220F-5, Horizontal, RM 1.7mm, PentawattF-, MultiwattF-5 +TO-220F-5 Horizontal RM 1.7mm PentawattF- MultiwattF-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x2.06mm_StaggerEven_Lead1.86mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-2 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x2.06mm_StaggerOdd_Lead1.86mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-1 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-2 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-1 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-7_P2.54x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-7, Vertical, RM 1.27mm, staggered type-2 +TO-220F-7 Vertical RM 1.27mm staggered type-2 +0 +7 +7 +Package_TO_SOT_THT +TO-220F-7_P2.54x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-7, Vertical, RM 1.27mm, staggered type-1 +TO-220F-7 Vertical RM 1.27mm staggered type-1 +0 +7 +7 +Package_TO_SOT_THT +TO-220F-9_P1.8x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-9, Vertical, RM 0.9mm, staggered type-2 +TO-220F-9 Vertical RM 0.9mm staggered type-2 +0 +9 +9 +Package_TO_SOT_THT +TO-220F-9_P1.8x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-9, Vertical, RM 0.9mm, staggered type-1 +TO-220F-9 Vertical RM 0.9mm staggered type-1 +0 +9 +9 +Package_TO_SOT_THT +TO-220F-11_P3.4x5.08mm_StaggerEven_Lead5.08mm_Vertical +TO-220F-11, Vertical, RM 1.7mm, MultiwattF-11, staggered type-2, see http://www.ti.com/lit/ds/symlink/lm3886.pdf +TO-220F-11 Vertical RM 1.7mm MultiwattF-11 staggered type-2 +0 +11 +11 +Package_TO_SOT_THT +TO-220F-11_P3.4x5.08mm_StaggerOdd_Lead5.08mm_Vertical +TO-220F-11, Vertical, RM 1.7mm, MultiwattF-11, staggered type-1, see http://www.ti.com/lit/ds/symlink/lm3886.pdf +TO-220F-11 Vertical RM 1.7mm MultiwattF-11 staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220F-15_P2.54x5.08mm_StaggerEven_Lead5.08mm_Vertical +TO-220F-15, Vertical, RM 1.27mm, MultiwattF-15, staggered type-2 +TO-220F-15 Vertical RM 1.27mm MultiwattF-15 staggered type-2 +0 +15 +15 +Package_TO_SOT_THT +TO-220F-15_P2.54x5.08mm_StaggerOdd_Lead5.08mm_Vertical +TO-220F-15, Vertical, RM 1.27mm, MultiwattF-15, staggered type-1 +TO-220F-15 Vertical RM 1.27mm MultiwattF-15 staggered type-1 +0 +15 +15 +Package_TO_SOT_THT +TO-247-2_Horizontal_TabDown +TO-247-2, Horizontal, RM 10.9mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-247-2_Horizontal_TabUp +TO-247-2, Horizontal, RM 10.9mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-247-2_Vertical +TO-247-2, Vertical, RM 10.9mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-2 Vertical RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-247-3_Horizontal_TabDown +TO-247-3, Horizontal, RM 5.45mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-247-3_Horizontal_TabUp +TO-247-3, Horizontal, RM 5.45mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-247-3_Vertical +TO-247-3, Vertical, RM 5.45mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-247-4_Horizontal_TabDown +TO-247-4, Horizontal, RM 2.54mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-247-4_Horizontal_TabUp +TO-247-4, Horizontal, RM 2.54mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-247-4_Vertical +TO-247-4, Vertical, RM 2.54mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-4 Vertical RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-247-5_Horizontal_TabDown +TO-247-5, Horizontal, RM 2.54mm, see http://ww1.microchip.com/downloads/en/DeviceDoc/20005685A.pdf +TO-247-5 Horizontal RM 2.54mm +0 +5 +5 +Package_TO_SOT_THT +TO-247-5_Horizontal_TabUp +TO-247-5, Horizontal, RM 2.54mm, see http://ww1.microchip.com/downloads/en/DeviceDoc/20005685A.pdf +TO-247-5 Horizontal RM 2.54mm +0 +5 +5 +Package_TO_SOT_THT +TO-247-5_Vertical +TO-247-5, Vertical, RM 2.54mm, see http://ww1.microchip.com/downloads/en/DeviceDoc/20005685A.pdf +TO-247-5 Vertical RM 2.54mm +0 +5 +5 +Package_TO_SOT_THT +TO-251-2-1EP_Horizontal_TabDown +TO-251-2, Horizontal, RM 4.58mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-2 Horizontal RM 4.58mm IPAK +0 +3 +3 +Package_TO_SOT_THT +TO-251-2_Vertical +TO-251-2, Vertical, RM 4.58mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-2 Vertical RM 4.58mm IPAK +0 +2 +2 +Package_TO_SOT_THT +TO-251-3-1EP_Horizontal_TabDown +TO-251-3, Horizontal, RM 2.29mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-3 Horizontal RM 2.29mm IPAK +0 +4 +4 +Package_TO_SOT_THT +TO-251-3_Vertical +TO-251-3, Vertical, RM 2.29mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-3 Vertical RM 2.29mm IPAK +0 +3 +3 +Package_TO_SOT_THT +TO-262-3-1EP_Horizontal_TabDown +TO-262-3, Horizontal, RM 2.54mm, IIPAK, I2PAK, see http://www.onsemi.com/pub/Collateral/EN8586-D.PDF +TO-262-3 Horizontal RM 2.54mm IIPAK I2PAK +0 +4 +4 +Package_TO_SOT_THT +TO-262-3_Vertical +TO-262-3, Vertical, RM 2.54mm, IIPAK, I2PAK, see http://www.onsemi.com/pub/Collateral/EN8586-D.PDF +TO-262-3 Vertical RM 2.54mm IIPAK I2PAK +0 +3 +3 +Package_TO_SOT_THT +TO-262-5-1EP_Horizontal_TabDown +TO-262-5, Horizontal, RM 1.7mm, IIPAK, I2PAK, see http://pdf.datasheetcatalog.com/datasheet/irf/iris4011.pdf +TO-262-5 Horizontal RM 1.7mm IIPAK I2PAK +0 +6 +6 +Package_TO_SOT_THT +TO-262-5_Vertical +TO-262-5, Vertical, RM 1.7mm, IIPAK, I2PAK, see http://pdf.datasheetcatalog.com/datasheet/irf/iris4011.pdf +TO-262-5 Vertical RM 1.7mm IIPAK I2PAK +0 +5 +5 +Package_TO_SOT_THT +TO-264-2_Horizontal_TabDown +TO-264-2, Horizontal, RM 10.9mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-264-2_Horizontal_TabUp +TO-264-2, Horizontal, RM 10.9mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-264-2_Vertical +TO-264-2, Vertical, RM 10.9mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-2 Vertical RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-264-3_Horizontal_TabDown +TO-264-3, Horizontal, RM 5.45mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-264-3_Horizontal_TabUp +TO-264-3, Horizontal, RM 5.45mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-264-3_Vertical +TO-264-3, Vertical, RM 5.45mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-264-5_Horizontal_TabDown +TO-264-5, Horizontal, RM 3.81mm, see https://www.onsemi.com/pub/Collateral/NJL3281D-D.PDF +TO-264-5 Horizontal RM 3.81mm +0 +5 +5 +Package_TO_SOT_THT +TO-264-5_Horizontal_TabUp +TO-264-5, Horizontal, RM 3.81mm, see https://www.onsemi.com/pub/Collateral/NJL3281D-D.PDF +TO-264-5 Horizontal RM 3.81mm +0 +5 +5 +Package_TO_SOT_THT +TO-264-5_Vertical +TO-264-5, Vertical, RM 3.81mm, see https://www.onsemi.com/pub/Collateral/NJL3281D-D.PDF +TO-264-5 Vertical RM 3.81mm +0 +5 +5 +Potentiometer_SMD +Potentiometer_ACP_CA6-VSMD_Vertical +Potentiometer, vertical, ACP CA6-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/06/01-ACP-CA6.pdf +Potentiometer vertical ACP CA6-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA6-VSMD_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA6-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/06/01-ACP-CA6.pdf +Potentiometer vertical hole ACP CA6-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA9-VSMD_Vertical +Potentiometer, vertical, ACP CA9-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical ACP CA9-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA9-VSMD_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA9-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical hole ACP CA9-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA14-VSMD_Vertical +Potentiometer, vertical, ACP CA14-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical ACP CA14-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA14-VSMD_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA14-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical hole ACP CA14-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214G_Horizontal +Potentiometer, horizontal, Bourns 3214G, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer horizontal Bourns 3214G +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214J_Horizontal +Potentiometer, horizontal, Bourns 3214J, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer horizontal Bourns 3214J +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214W_Vertical +Potentiometer, vertical, Bourns 3214W, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer vertical Bourns 3214W +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214X_Vertical +Potentiometer, vertical, Bourns 3214X, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer vertical Bourns 3214X +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224G_Horizontal +Potentiometer, horizontal, Bourns 3224G, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer horizontal Bourns 3224G +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224J_Horizontal +Potentiometer, horizontal, Bourns 3224J, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer horizontal Bourns 3224J +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224W_Vertical +Potentiometer, vertical, Bourns 3224W, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer vertical Bourns 3224W +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224X_Vertical +Potentiometer, vertical, Bourns 3224X, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer vertical Bourns 3224X +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3269P_Horizontal +Potentiometer, horizontal, Bourns 3269P, https://www.bourns.com/docs/Product-Datasheets/3269.pdf +Potentiometer horizontal Bourns 3269P +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3269W_Vertical +Potentiometer, vertical, Bourns 3269W, https://www.bourns.com/docs/Product-Datasheets/3269.pdf +Potentiometer vertical Bourns 3269W +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3269X_Horizontal +Potentiometer, horizontal, Bourns 3269X, https://www.bourns.com/docs/Product-Datasheets/3269.pdf +Potentiometer horizontal Bourns 3269X +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314G_Vertical +Potentiometer, vertical, Bourns 3314G, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical Bourns 3314G +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314J_Vertical +Potentiometer, vertical, Bourns 3314J, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical Bourns 3314J +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314R-1_Vertical_Hole +Potentiometer, vertical, shaft hole, Bourns 3314R-1, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical hole Bourns 3314R-1 +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314R-GM5_Vertical +Potentiometer, vertical, Bourns 3314R-GM5, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical Bourns 3314R-GM5 +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314S_Horizontal +Potentiometer, horizontal, Bourns 3314S, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer horizontal Bourns 3314S +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_PRS11S_Vertical +Potentiometer, vertical, Bourns PRS11S, http://www.bourns.com/docs/Product-Datasheets/PRS11S.pdf +Potentiometer vertical Bourns PRS11S +0 +5 +5 +Potentiometer_SMD +Potentiometer_Bourns_TC33X_Vertical +Potentiometer, Bourns, TC33X, Vertical, https://www.bourns.com/pdfs/TC33.pdf +Potentiometer Bourns TC33X Vertical +0 +3 +3 +Potentiometer_SMD +Potentiometer_Vishay_TS53YJ_Vertical +Potentiometer, vertical, Vishay TS53YJ, https://www.vishay.com/docs/51008/ts53.pdf +Potentiometer vertical Vishay TS53YJ +0 +3 +3 +Potentiometer_SMD +Potentiometer_Vishay_TS53YL_Vertical +Potentiometer, vertical, Vishay TS53YL, https://www.vishay.com/docs/51008/ts53.pdf +Potentiometer vertical Vishay TS53YL +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA6-H2,5_Horizontal +Potentiometer, horizontal, ACP CA6-H2,5, http://www.acptechnologies.com/wp-content/uploads/2017/06/01-ACP-CA6.pdf +Potentiometer horizontal ACP CA6-H2,5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-H2,5_Horizontal +Potentiometer, horizontal, ACP CA9-H2,5, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer horizontal ACP CA9-H2,5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-H3,8_Horizontal +Potentiometer, horizontal, ACP CA9-H3,8, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer horizontal ACP CA9-H3,8 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-H5_Horizontal +Potentiometer, horizontal, ACP CA9-H5, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer horizontal ACP CA9-H5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-V10_Vertical +Potentiometer, vertical, ACP CA9-V10, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical ACP CA9-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-V10_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA9-V10, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical hole ACP CA9-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14-H2,5_Horizontal +Potentiometer, horizontal, ACP CA14-H2,5, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer horizontal ACP CA14-H2,5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14-H4_Horizontal +Potentiometer, horizontal, ACP CA14-H4, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer horizontal ACP CA14-H4 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14-H5_Horizontal +Potentiometer, horizontal, ACP CA14-H5, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer horizontal ACP CA14-H5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14V-15_Vertical +Potentiometer, vertical, ACP CA14V-15, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical ACP CA14V-15 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14V-15_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA14V-15, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical hole ACP CA14V-15 +0 +3 +3 +Potentiometer_THT +Potentiometer_Alpha_RD901F-40-00D_Single_Vertical +Potentiometer, vertical, 9mm, single, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alpha_RD901F-40-00D_Single_Vertical_CircularHoles +Potentiometer, vertical, 9mm, single, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alpha_RD902F-40-00D_Dual_Vertical +Potentiometer, vertical, 9mm, dual, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm dual +0 +8 +6 +Potentiometer_THT +Potentiometer_Alpha_RD902F-40-00D_Dual_Vertical_CircularHoles +Potentiometer, vertical, 9mm, dual, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm dual +0 +8 +6 +Potentiometer_THT +Potentiometer_Alps_RK09K_Single_Horizontal +Potentiometer, horizontal, Alps RK09K Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09K/RK09K_list.html +Potentiometer horizontal Alps RK09K Single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alps_RK09K_Single_Vertical +Potentiometer, vertical, Alps RK09K Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09K/RK09K_list.html +Potentiometer vertical Alps RK09K Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK09L_Double_Horizontal +Potentiometer, horizontal, Alps RK09L Double, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer horizontal Alps RK09L Double +0 +8 +6 +Potentiometer_THT +Potentiometer_Alps_RK09L_Double_Vertical +Potentiometer, vertical, Alps RK09L Double, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer vertical Alps RK09L Double +0 +6 +6 +Potentiometer_THT +Potentiometer_Alps_RK09L_Single_Horizontal +Potentiometer, horizontal, Alps RK09L Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer horizontal Alps RK09L Single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alps_RK09L_Single_Vertical +Potentiometer, vertical, Alps RK09L Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer vertical Alps RK09L Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK09Y11_Single_Horizontal +Potentiometer, horizontal, Alps RK09Y11 Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09Y11/RK09Y11_list.html +Potentiometer horizontal Alps RK09Y11 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK097_Dual_Horizontal +Potentiometer, horizontal, Alps RK097 Dual, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK097/RK097_list.html +Potentiometer horizontal Alps RK097 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Alps_RK097_Single_Horizontal +Potentiometer, horizontal, Alps RK097 Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK097/RK097_list.html +Potentiometer horizontal Alps RK097 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK163_Dual_Horizontal +Potentiometer, horizontal, Alps RK163 Dual, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK16/RK16_list.html +Potentiometer horizontal Alps RK163 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Alps_RK163_Single_Horizontal +Potentiometer, horizontal, Alps RK163 Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK16/RK16_list.html +Potentiometer horizontal Alps RK163 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3005_Horizontal +Potentiometer, horizontal, Bourns 3005, http://www.bourns.com/docs/Product-Datasheets/3005.pdf +Potentiometer horizontal Bourns 3005 +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3006P_Horizontal +Potentiometer, horizontal, Bourns 3006P, https://www.bourns.com/docs/Product-Datasheets/3006.pdf +Potentiometer horizontal Bourns 3006P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3006W_Horizontal +Potentiometer, horizontal, Bourns 3006W, https://www.bourns.com/docs/Product-Datasheets/3006.pdf +Potentiometer horizontal Bourns 3006W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3006Y_Horizontal +Potentiometer, horizontal, Bourns 3006Y, https://www.bourns.com/docs/Product-Datasheets/3006.pdf +Potentiometer horizontal Bourns 3006Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3009P_Horizontal +Potentiometer, horizontal, Bourns 3009P, http://www.bourns.com/docs/Product-Datasheets/3009.pdf +Potentiometer horizontal Bourns 3009P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3009Y_Horizontal +Potentiometer, horizontal, Bourns 3009Y, http://www.bourns.com/docs/Product-Datasheets/3009.pdf +Potentiometer horizontal Bourns 3009Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266P_Horizontal +Potentiometer, horizontal, Bourns 3266P, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer horizontal Bourns 3266P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266W_Vertical +Potentiometer, vertical, Bourns 3266W, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer vertical Bourns 3266W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266X_Horizontal +Potentiometer, horizontal, Bourns 3266X, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer horizontal Bourns 3266X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266Y_Vertical +Potentiometer, vertical, Bourns 3266Y, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer vertical Bourns 3266Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266Z_Horizontal +Potentiometer, horizontal, Bourns 3266Z, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer horizontal Bourns 3266Z +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296P_Horizontal +Potentiometer, horizontal, Bourns 3296P, https://www.bourns.com/pdfs/3296.pdf +Potentiometer horizontal Bourns 3296P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296W_Vertical +Potentiometer, vertical, Bourns 3296W, https://www.bourns.com/pdfs/3296.pdf +Potentiometer vertical Bourns 3296W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296X_Horizontal +Potentiometer, horizontal, Bourns 3296X, https://www.bourns.com/pdfs/3296.pdf +Potentiometer horizontal Bourns 3296X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296Y_Vertical +Potentiometer, vertical, Bourns 3296Y, https://www.bourns.com/pdfs/3296.pdf +Potentiometer vertical Bourns 3296Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296Z_Horizontal +Potentiometer, horizontal, Bourns 3296Z, https://www.bourns.com/pdfs/3296.pdf +Potentiometer horizontal Bourns 3296Z +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299P_Horizontal +Potentiometer, horizontal, Bourns 3299P, https://www.bourns.com/pdfs/3299.pdf +Potentiometer horizontal Bourns 3299P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299W_Vertical +Potentiometer, vertical, Bourns 3299W, https://www.bourns.com/pdfs/3299.pdf +Potentiometer vertical Bourns 3299W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299X_Horizontal +Potentiometer, horizontal, Bourns 3299X, https://www.bourns.com/pdfs/3299.pdf +Potentiometer horizontal Bourns 3299X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299Y_Vertical +Potentiometer, vertical, Bourns 3299Y, https://www.bourns.com/pdfs/3299.pdf +Potentiometer vertical Bourns 3299Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299Z_Horizontal +Potentiometer, horizontal, Bourns 3299Z, https://www.bourns.com/pdfs/3299.pdf +Potentiometer horizontal Bourns 3299Z +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339H_Vertical +Potentiometer, vertical, Bourns 3339H, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer vertical Bourns 3339H +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339P_Vertical +Potentiometer, vertical, Bourns 3339P, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer vertical Bourns 3339P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339P_Vertical_HandSoldering +Potentiometer, vertical, Bourns 3339P, hand-soldering, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer vertical Bourns 3339P hand-soldering +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339S_Horizontal +Potentiometer, horizontal, Bourns 3339S, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer horizontal Bourns 3339S +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339W_Horizontal +Potentiometer, horizontal, Bourns 3339W, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer horizontal Bourns 3339W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386C_Horizontal +Potentiometer, horizontal, Bourns 3386C, https://www.bourns.com/pdfs/3386.pdf +Potentiometer horizontal Bourns 3386C +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386F_Vertical +Potentiometer, vertical, Bourns 3386F, https://www.bourns.com/pdfs/3386.pdf +Potentiometer vertical Bourns 3386F +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386P_Vertical +Potentiometer, vertical, Bourns 3386P, https://www.bourns.com/pdfs/3386.pdf +Potentiometer vertical Bourns 3386P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386X_Horizontal +Potentiometer, horizontal, Bourns 3386X, https://www.bourns.com/pdfs/3386.pdf +Potentiometer horizontal Bourns 3386X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_PTA1543_Single_Slide +Bourns single-gang slide potentiometer, 15.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 15.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA2043_Single_Slide +Bourns single-gang slide potentiometer, 20.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 20.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA3043_Single_Slide +Bourns single-gang slide potentiometer, 30.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 30.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA4543_Single_Slide +Bourns single-gang slide potentiometer, 45.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 45.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA6043_Single_Slide +Bourns single-gang slide potentiometer, 60.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 60.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTV09A-1_Single_Vertical +Potentiometer, vertical, Bourns PTV09A-1 Single, http://www.bourns.com/docs/Product-Datasheets/ptv09.pdf +Potentiometer vertical Bourns PTV09A-1 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_PTV09A-2_Single_Horizontal +Potentiometer, horizontal, Bourns PTV09A-2 Single, http://www.bourns.com/docs/Product-Datasheets/ptv09.pdf +Potentiometer horizontal Bourns PTV09A-2 Single +0 +5 +3 +Potentiometer_THT +Potentiometer_Omeg_PC16BU_Horizontal +Potentiometer, horizontal, Omeg PC16BU, http://www.omeg.co.uk/pc6bubrc.htm +Potentiometer horizontal Omeg PC16BU +0 +3 +3 +Potentiometer_THT +Potentiometer_Omeg_PC16BU_Vertical +Potentiometer, vertical, Omeg PC16BU, http://www.omeg.co.uk/pc6bubrc.htm +Potentiometer vertical Omeg PC16BU +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PC-16_Dual_Horizontal +Potentiometer, horizontal, Piher PC-16 Dual, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer horizontal Piher PC-16 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Piher_PC-16_Single_Horizontal +Potentiometer, horizontal, Piher PC-16 Single, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer horizontal Piher PC-16 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PC-16_Single_Vertical +Potentiometer, vertical, Piher PC-16 Single, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer vertical Piher PC-16 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PC-16_Triple_Horizontal +Potentiometer, horizontal, Piher PC-16 Triple, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer horizontal Piher PC-16 Triple +0 +9 +9 +Potentiometer_THT +Potentiometer_Piher_PT-6-H_Horizontal +Potentiometer, horizontal, Piher PT-6-H, http://www.piher-nacesa.com/pdf/11-PT6v03.pdf +Potentiometer horizontal Piher PT-6-H +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-6-V_Vertical +Potentiometer, vertical, Piher PT-6-V, http://www.piher-nacesa.com/pdf/11-PT6v03.pdf +Potentiometer vertical Piher PT-6-V +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-6-V_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-6-V, http://www.piher-nacesa.com/pdf/11-PT6v03.pdf +Potentiometer vertical hole Piher PT-6-V +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-H01_Horizontal +Potentiometer, horizontal, Piher PT-10-H01, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer horizontal Piher PT-10-H01 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-H05_Horizontal +Potentiometer, horizontal, Piher PT-10-H05, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer horizontal Piher PT-10-H05 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-V05_Vertical +Potentiometer, vertical, Piher PT-10-V05, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer vertical Piher PT-10-V05 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-V10_Vertical +Potentiometer, vertical, Piher PT-10-V10, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer vertical Piher PT-10-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-V10_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-10-V10, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer vertical hole Piher PT-10-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H01_Horizontal +Potentiometer, horizontal, Piher PT-15-H01, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H01 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H05_Horizontal +Potentiometer, horizontal, Piher PT-15-H05, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H05 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H06_Horizontal +Potentiometer, horizontal, Piher PT-15-H06, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H06 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H25_Horizontal +Potentiometer, horizontal, Piher PT-15-H25, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H25 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V02_Vertical +Potentiometer, vertical, Piher PT-15-V02, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical Piher PT-15-V02 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V02_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-15-V02, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical hole Piher PT-15-V02 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V15_Vertical +Potentiometer, vertical, Piher PT-15-V15, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical Piher PT-15-V15 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V15_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-15-V15, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical hole Piher PT-15-V15 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_T-16H_Double_Horizontal +Potentiometer, horizontal, Piher T-16H Double, http://www.piher-nacesa.com/pdf/22-T16v03.pdf +Potentiometer horizontal Piher T-16H Double +0 +6 +6 +Potentiometer_THT +Potentiometer_Piher_T-16H_Single_Horizontal +Potentiometer, horizontal, Piher T-16H Single, http://www.piher-nacesa.com/pdf/22-T16v03.pdf +Potentiometer horizontal Piher T-16H Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_T-16L_Single_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher T-16L Single, http://www.piher-nacesa.com/pdf/22-T16v03.pdf +Potentiometer vertical hole Piher T-16L Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Runtron_RM-063_Horizontal +Potentiometer, horizontal, Trimmer, RM-063 http://www.runtron.com/down/PDF%20Datasheet/Carbon%20Film%20Potentiometer/RM065%20RM063.pdf +Potentiometer Trimmer RM-063 +0 +3 +3 +Potentiometer_THT +Potentiometer_Runtron_RM-065_Vertical +Potentiometer, vertical, Trimmer, RM-065 http://www.runtron.com/down/PDF%20Datasheet/Carbon%20Film%20Potentiometer/RM065%20RM063.pdf +Potentiometer Trimmer RM-065 +0 +3 +3 +Potentiometer_THT +Potentiometer_TT_P0915N +http://www.ttelectronics.com/sites/default/files/download-files/Datasheet_PanelPot_P09xSeries.pdf +potentiometer vertical TT P0915N single +0 +5 +3 +Potentiometer_THT +Potentiometer_Vishay_43_Horizontal +Potentiometer, horizontal, Vishay 43, http://www.vishay.com/docs/57026/43.pdf +Potentiometer horizontal Vishay 43 +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_148-149_Dual_Horizontal +Potentiometer, horizontal, Vishay 148-149 Dual, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148-149 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Vishay_148-149_Single_Horizontal +Potentiometer, horizontal, Vishay 148-149 Single, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148-149 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_148-149_Single_Vertical +Potentiometer, vertical, Vishay 148-149 Single, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer vertical Vishay 148-149 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_148E-149E_Dual_Horizontal +Potentiometer, horizontal, Vishay 148E-149E Dual, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148E-149E Dual +0 +10 +6 +Potentiometer_THT +Potentiometer_Vishay_148E-149E_Single_Horizontal +Potentiometer, horizontal, Vishay 148E-149E Single, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148E-149E Single +0 +7 +3 +Potentiometer_THT +Potentiometer_Vishay_248BH-249BH_Single_Horizontal +Potentiometer, horizontal, Vishay 248BH-249BH Single, http://www.vishay.com/docs/57054/248249.pdf +Potentiometer horizontal Vishay 248BH-249BH Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_248GJ-249GJ_Single_Horizontal +Potentiometer, horizontal, Vishay 248GJ-249GJ Single, http://www.vishay.com/docs/57054/248249.pdf +Potentiometer horizontal Vishay 248GJ-249GJ Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_248GJ-249GJ_Single_Vertical +Potentiometer, vertical, Vishay 248GJ-249GJ Single, http://www.vishay.com/docs/57054/248249.pdf +Potentiometer vertical Vishay 248GJ-249GJ Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T7-YA_Single_Vertical +Potentiometer, vertical, Vishay T7-YA Single, http://www.vishay.com/docs/51015/t7.pdf +Potentiometer vertical Vishay T7-YA Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T73XW_Horizontal +Potentiometer, horizontal, Vishay T73XW, http://www.vishay.com/docs/51016/t73.pdf +Potentiometer horizontal Vishay T73XW +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T73XX_Horizontal +Potentiometer, horizontal, Vishay T73XX, http://www.vishay.com/docs/51016/t73.pdf +Potentiometer horizontal Vishay T73XX +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T73YP_Vertical +Potentiometer, vertical, Vishay T73YP, http://www.vishay.com/docs/51016/t73.pdf +Potentiometer vertical Vishay T73YP +0 +3 +3 +RF +Skyworks_SKY13575_639LF +http://www.skyworksinc.com/uploads/documents/SKY13575_639LF_203270D.pdf +Skyworks +0 +19 +15 +RF +Skyworks_SKY65404-31 +http://www.skyworksinc.com/uploads/documents/SKY65404_31_201512K.pdf +Skyworks +0 +7 +7 +RF_Antenna +Abracon_APAES868R8060C16-T +Abracon RHCP ceramic patch antenna 854-882Mhz, 5dBi +APAES patch antenna +0 +1 +1 +RF_Antenna +Coilcraft_MA5532-AE_RFID +RFID Transponder Coil +antenna rfid coilcraft +0 +2 +2 +RF_Antenna +Johanson_2450AT18x100 +Johanson 2450AT43F0100 SMD antenna 2400-2500Mhz, -0.5dBi, https://www.johansontechnology.com/datasheets/2450AT18A100/2450AT18A100.pdf +antenna +0 +2 +2 +RF_Antenna +Johanson_2450AT43F0100 +Johanson 2450AT43F0100 SMD antenna 2400-2500Mhz, 1dBi, https://www.johansontechnology.com/datasheets/2450AT43F0100/2450AT43F0100.pdf +antenna +0 +2 +2 +RF_Antenna +Pulse_W3011 +Pulse RF Antenna, 4mm Clearance +antenna rf +0 +3 +2 +RF_Antenna +Texas_SWRA117D_2.4GHz_Left +http://www.ti.com/lit/an/swra117d/swra117d.pdf +PCB antenna +0 +2 +2 +RF_Antenna +Texas_SWRA117D_2.4GHz_Right +http://www.ti.com/lit/an/swra117d/swra117d.pdf +PCB antenna +0 +2 +2 +RF_Antenna +Texas_SWRA416_868MHz_915MHz +http://www.ti.com/lit/an/swra416/swra416.pdf +PCB antenna +0 +20 +1 +RF_Converter +Anaren_0805_2012Metric-6 +https://cdn.anaren.com/product-documents/Xinger/DirectionalCouplers/DC4759J5020AHF/DC4759J5020AHF_DataSheet(Rev_E).pdf +coupler rf +0 +6 +6 +RF_Converter +Balun_Johanson_1.6x0.8mm +6-pin 1.6x0.8 mm balun footprint +Johanson balun filter +0 +6 +6 +RF_Converter +Balun_Johanson_5400BL15B050E +https://www.johansontechnology.com/datasheets/5400BL15B050/5400BL15B050.pdf +balun RF +0 +6 +6 +RF_Converter +RF_Attenuator_Susumu_PAT1220 +http://www.susumu-usa.com/pdf/Foot_Print_38.pdf, https://www.susumu.co.jp/common/pdf/n_catalog_partition16_en.pdf +2mm 1.2mm +0 +3 +3 +RF_GPS +Linx_RXM-GPS +GPS Module, Linx +gps linx +0 +22 +22 +RF_GPS +SIM28ML +https://simcom.ee/documents/SIM28ML/SIM28ML_Hardware%20Design_V1.01.pdf +SIM28ML GPS +0 +18 +18 +RF_GPS +Sierra_XA11X0 +QFN-24, Pitch 1.20 no EP, https://source.sierrawireless.com/resources/airprime/hardware_specs_user_guides/airprime_xm1100_product_technical_specification +QFN-24 P1.20 +0 +24 +24 +RF_GPS +Sierra_XM11X0 +QFN-20, Pitch 1.20 no EP, https://source.sierrawireless.com/resources/airprime/hardware_specs_user_guides/airprime_xm1100_product_technical_specification +QFN-20 P1.20 +0 +20 +20 +RF_GPS +ublox_LEA +ublox LEA 6/7/8, (https://www.u-blox.com/sites/default/files/LEA-M8S-M8T-FW3_HardwareIntegrationManual_%28UBX-15030060%29.pdf) +GPS ublox LEA 6/7/8 +0 +28 +28 +RF_GPS +ublox_MAX +ublox MAX 6/7/8, (https://www.u-blox.com/sites/default/files/MAX-8-M8-FW3_HardwareIntegrationManual_%28UBX-15030059%29.pdf) +GPS ublox MAX 6/7/8 +0 +18 +18 +RF_GPS +ublox_NEO +ublox NEO 6/7/8, (https://www.u-blox.com/sites/default/files/NEO-8Q-NEO-M8-FW3_HardwareIntegrationManual_%28UBX-15029985%29_0.pdf) +GPS ublox NEO 6/7/8 +0 +24 +24 +RF_GPS +ublox_SAM-M8Q +GPS Module, 15.5x15.5x6.3mm, https://www.u-blox.com/sites/default/files/SAM-M8Q_HardwareIntegrationManual_%28UBX-16018358%29.pdf +ublox SAM-M8Q +0 +100 +20 +RF_GPS +ublox_SAM-M8Q_HandSolder +GPS Module, 15.5x15.5x6.3mm, https://www.u-blox.com/sites/default/files/SAM-M8Q_HardwareIntegrationManual_%28UBX-16018358%29.pdf +ublox SAM-M8Q +0 +20 +20 +RF_GPS +ublox_ZED +ublox ZED-F9, https://www.u-blox.com/sites/default/files/ZED-F9P_DataSheet_%28UBX-17051259%29.pdf +GPS GNSS ublox ZED +0 +102 +55 +RF_GSM +Quectel_BC66 +GSM NB-IoT module, 15.8x17.7x2mm, https://www.quectel.com/UploadImage/Downlad/Quectel_BC66_Hardware_Design_V1.1.pdf +GSM NB-IoT Module BC66 M66 +0 +116 +58 +RF_GSM +SIMCom_SIM800C +Quad-Band GSM/GPRS module, 17.6x15.7x2.3mm, http://simcom.ee/documents/SIM800C/SIM800C_Hardware_Design_V1.05.pdf +GSM Module SIM800C +0 +84 +42 +RF_GSM +SIMCom_SIM900 +Quad-Band GSM/GPRS module, 24x24x3mm, http://simcom.ee/documents/SIM900/SIM900_Hardware%20Design_V2.05.pdf +GSM Module SIM900 +0 +68 +68 +RF_GSM +Telit_xL865 +Telit xL865 familly footprint, http://www.telit.com/fileadmin/user_upload/products/Downloads/3G/Telit_UL865_Hardware_User_Guide_r8.pdf +xL865 gsm umts +0 +52 +48 +RF_GSM +ublox_SARA-G3_LGA-96 +ublox Sara GSM/HSPA modem, https://www.u-blox.com/sites/default/files/SARA-G3-U2_SysIntegrManual_%28UBX-13000995%29.pdf, pag.162 +ublox SARA-G3 SARA-U2 GSM HSPA +0 +192 +96 +RF_Mini-Circuits +Mini-Circuits_BK377 +Footprint for Mini-Circuits case BK377 (https://ww2.minicircuits.com/case_style/BK276.pdf) +Mini-circuits BK377 +0 +14 +14 +RF_Mini-Circuits +Mini-Circuits_BK377_LandPatternPL-005 +Footprint for Mini-Circuits case BK377 (https://ww2.minicircuits.com/case_style/BK276.pdf) according to land-pattern PL-005, including GND vias (https://ww2.minicircuits.com/pcb/98-pl005.pdf) +Mini-circuits VCXO JTOS PL-005 +0 +50 +14 +RF_Mini-Circuits +Mini-Circuits_CD541_H2.08mm +https://ww2.minicircuits.com/case_style/CD541.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CD542_H2.84mm +https://ww2.minicircuits.com/case_style/CD542.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CD542_LandPatternPL-052 +Footprint for Mini-Circuits case CD542 (https://ww2.minicircuits.com/case_style/CD542.pdf) using land-pattern PL-052, including GND-vias (https://ww2.minicircuits.com/pcb/98-pl052.pdf) +MiniCircuits PL-052 CD542 +0 +17 +6 +RF_Mini-Circuits +Mini-Circuits_CD542_LandPatternPL-094 +Footprint for mini circuit case CD542, Land pattern PL-094, pads 5 and 2 connected via insulated copper area below body, vias included (case drawing: https://ww2.minicircuits.com/case_style/CD542.pdf, land pattern drawing: https://ww2.minicircuits.com/pcb/98-pl094.pdf) +mini-circuits CD542 pl-094 +0 +18 +6 +RF_Mini-Circuits +Mini-Circuits_CD636_H4.11mm +https://ww2.minicircuits.com/case_style/CD636.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CD636_LandPatternPL-035 +Footprint for Mini-Circuits case CD636 (https://ww2.minicircuits.com/case_style/CD636.pdf) following land pattern PL-035, including GND-vias (https://ww2.minicircuits.com/pcb/98-pl035.pdf) +mini-circuits pl-035 CD636 +0 +13 +6 +RF_Mini-Circuits +Mini-Circuits_CD637_H5.23mm +https://ww2.minicircuits.com/case_style/CD637.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CK605 +Footprint for Mini-Circuits case CK605 (https://ww2.minicircuits.com/case_style/CK605.pdf) +Mini-Circuits CK605 +0 +16 +16 +RF_Mini-Circuits +Mini-Circuits_CK605_LandPatternPL-012 +Footprint for Mini-Circuits case CK605 (https://ww2.minicircuits.com/case_style/CK605.pdf) following land pattern PL-012, including GND vias (https://ww2.minicircuits.com/pcb/98-pl012.pdf) +Mini-Circuits PL-012 +0 +53 +16 +RF_Mini-Circuits +Mini-Circuits_DB1627 +Mini-Circuits top-hat case DB1627 (https://ww2.minicircuits.com/case_style/DB1627.pdf) +Mini-Circuits DB1627 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_GP731 +Footprint for Mini-Circuits case GP731 (https://ww2.minicircuits.com/case_style/GP731.pdf) +Mini-Circuits GP731 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_GP731_LandPatternPL-176 +Footprint for Mini-Circuits case GP731 (https://ww2.minicircuits.com/case_style/GP731.pdf) following land pattern PL-176, including GND vias (https://www.minicircuits.com/pcb/98-pl176.pdf) +mini-circuits PL-176 +0 +21 +8 +RF_Mini-Circuits +Mini-Circuits_GP1212 +Footprint for Mini-Circuits case GP1212 (https://ww2.minicircuits.com/case_style/GP731.pdf) +mini-circuits GP1212 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_GP1212_LandPatternPL-176 +Footprint for Mini-Circuits case GP1212 (https://ww2.minicircuits.com/case_style/GP731.pdf) following land pattern PL-176, including GND vias (https://www.minicircuits.com/pcb/98-pl176.pdf) +mini-circuits PL-176 +0 +21 +8 +RF_Mini-Circuits +Mini-Circuits_HF1139 +Footprint for Mini-Circuits case HF1139 (https://ww2.minicircuits.com/case_style/HF1139.pdf) +Mini-Circuits HF1139 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_HF1139_LandPatternPL-230 +Footprint for Mini-Circuits case HF1139 (https://ww2.minicircuits.com/case_style/HF1139.pdf) following land pattern PL-230, including GND vias (https://ww2.minicircuits.com/pcb/98-pl230.pdf) +Mini-Circuits PL-230 +0 +37 +8 +RF_Mini-Circuits +Mini-Circuits_HQ1157 +Footprint for Mini-Circuits case HQ1157 (https://www.minicircuits.com/case_style/HQ1157.pdf) +Mini-Circuits HQ1157 +0 +14 +14 +RF_Mini-Circuits +Mini-Circuits_HZ1198 +Footprint for Mini-Circuits case HZ1198 (https://ww2.minicircuits.com/case_style/HZ1198.pdf) +Mini-Circuits HZ1198 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_HZ1198_LandPatternPL-247 +Footprint for Mini-Circuits cas HZ1198 (https://ww2.minicircuits.com/case_style/HZ1198.pdf) following land pattern PL-247, including GND-vias (https://www.minicircuits.com/pcb/98-pl247.pdf) +Mini-Circuits PL-247 HZ1198 +0 +40 +6 +RF_Mini-Circuits +Mini-Circuits_MMM168 +Footprint for Mini-Circuits case MMM168 (https://ww2.minicircuits.com/case_style/MMM168.pdf) +Mini-Circuits MMM168 +0 +4 +4 +RF_Mini-Circuits +Mini-Circuits_MMM168_LandPatternPL-225 +Footprint for Mini-Circuits case MMM168, Land pattern PL-225, vias included, (case drawing: https://ww2.minicircuits.com/case_style/MMM168.pdf, land pattern drawing: https://ww2.minicircuits.com/pcb/98-pl225.pdf) +pl-225 +0 +10 +4 +RF_Mini-Circuits +Mini-Circuits_QQQ130_ClockwisePinNumbering +Footprint for Mini-Circuits case QQQ130 (https://ww2.minicircuits.com/case_style/QQQ130.pdf) +Mini-Circuits QQQ130 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_QQQ130_LandPattern_PL-236_ClockwisePinNumbering +Footprint for Mini-Circuits case QQQ130 (https://ww2.minicircuits.com/case_style/QQQ130.pdf) following land pattern PL-236, including GND vias (https://ww2.minicircuits.com/pcb/98-pl236.pdf) +Mini-Circuits PL-236 +0 +14 +6 +RF_Mini-Circuits +Mini-Circuits_TT1224_ClockwisePinNumbering +Footprint for Mini-Circuits case TT1224 (https://ww2.minicircuits.com/case_style/TT1224.pdf) following land-pattern PL-258, including GND-vias (https://www.minicircuits.com/pcb/98-pl258.pdf) +Mini-Circuits TT1224 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_TT1224_LandPatternPL-258_ClockwisePinNumbering +Footprint for Mini-Circuits case TT1224 (https://ww2.minicircuits.com/case_style/TT1224.pdf) following land-pattern PL-258, including GND-vias (https://www.minicircuits.com/pcb/98-pl258.pdf) +PL-258 Mini-Circuits +0 +26 +6 +RF_Mini-Circuits +Mini-Circuits_TTT167 +Footprint for Mini-Circuits case TTT167 (https://ww2.minicircuits.com/case_style/TTT167.pdf) +Mini-Circuits TTT167 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_TTT167_LandPatternPL-079 +Footprint for Mini-Circuits case TTT167 (Mini-Circuits_TTT167_LandPatternPL-079) following land pattern PL-079, including GND vias (https://ww2.minicircuits.com/pcb/98-pl079.pdf) +Mini-Circuits PL-079 +0 +36 +6 +RF_Mini-Circuits +Mini-Circuits_YY161 +Footprint for Mini-Circuits case YY161 (https://ww2.minicircuits.com/case_style/YY161.pdf) +Mini-Circuits YY161 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_YY161_LandPatternPL-049 +Footprint for Mini-Circuits case YY161 (https://ww2.minicircuits.com/case_style/YY161.pdf) using land-pattern PL-049, including GND-connections and vias (https://ww2.minicircuits.com/pcb/98-pl049.pdf) +mini-circuits pl-049 +0 +36 +8 +RF_Module +Ai-Thinker-Ra-01-LoRa +Ai Thinker Ra-01 LoRa +LoRa Ra-01 +0 +16 +16 +RF_Module +Atmel_ATSAMR21G18-MR210UA_NoRFPads +http://ww1.microchip.com/downloads/en/devicedoc/atmel-42475-atsamr21g18-mr210ua_datasheet.pdf +module wireless zigbee 802.15.4 flash crypto ATSAMR21G18 AT45DB041E TECC508A U.Fi +0 +42 +42 +RF_Module +BLE112-A +Class 4 Bluetooth Module with on-board antenna +Bluetooth Module +0 +30 +30 +RF_Module +CMWX1ZZABZ +https://wireless.murata.com/RFM/data/type_abz.pdf +iot lora sigfox +0 +57 +57 +RF_Module +CYBLE-21Pin-10x10mm +Cypress EZ-BLE PRoC Module (Bluetooth Smart) 21 Pin Module +Cypress BT Bluetooth +0 +21 +21 +RF_Module +DWM1000 +IEEE802.15.4-2011 UWB +UWB Module +0 +24 +24 +RF_Module +DecaWave_DWM1001 +https://www.decawave.com/sites/default/files/dwm1001_datasheet.pdf +UWB module +0 +34 +34 +RF_Module +Digi_XBee_SMT +http://www.digi.com/resources/documentation/digidocs/pdfs/90002126.pdf http://ftp1.digi.com/support/documentation/90001020_F.pdf +Digi XBee SMT RF +0 +37 +37 +RF_Module +E18-MS1-PCB +http://www.cdebyte.com/en/downpdf.aspx?id=122 +Zigbee +0 +24 +24 +RF_Module +E73-2G4M04S +http://www.cdebyte.com/en/downpdf.aspx?id=243 +BLE BLE5 nRF52832 +0 +44 +44 +RF_Module +ESP-07 +Wi-Fi Module, http://wiki.ai-thinker.com/_media/esp8266/docs/a007ps01a2_esp-07_product_specification_v1.2.pdf +Wi-Fi Module +0 +16 +16 +RF_Module +ESP-12E +Wi-Fi Module, http://wiki.ai-thinker.com/_media/esp8266/docs/aithinker_esp_12f_datasheet_en.pdf +Wi-Fi Module +0 +22 +22 +RF_Module +ESP-WROOM-02 +http://espressif.com/sites/default/files/documentation/0c-esp-wroom-02_datasheet_en.pdf +ESP WROOM-02 espressif esp8266ex +0 +19 +19 +RF_Module +ESP32-S2-WROVER +ESP32-S2-WROVER(-I) 2.4 GHz Wi-Fi https://www.espressif.com/sites/default/files/documentation/esp32-s2-wroom_esp32-s2-wroom-i_datasheet_en.pdf +ESP32-S2 ESP32 WIFI +0 +43 +43 +RF_Module +ESP32-WROOM-32 +Single 2.4 GHz Wi-Fi and Bluetooth combo chip https://www.espressif.com/sites/default/files/documentation/esp32-wroom-32_datasheet_en.pdf +Single 2.4 GHz Wi-Fi and Bluetooth combo chip +0 +39 +39 +RF_Module +ESP32-WROOM-32U +Single 2.4 GHz Wi-Fi and Bluetooth combo chip with U.FL connector, https://www.espressif.com/sites/default/files/documentation/esp32-wroom-32d_esp32-wroom-32u_datasheet_en.pdf +Single 2.4 GHz Wi-Fi and Bluetooth combo chip +0 +39 +39 +RF_Module +Garmin_M8-35_9.8x14.0mm_Layout6x6_P1.5mm +D52M ANT SoC Module https://www.thisisant.com/assets/resources/D00001687_D52_Module_Datasheet.v.2.3_(Garmin).pdf +RF SoC Radio ANT Bluetooth BLE D52 nRF52 Garmin Canada Dynastream Nordic +0 +35 +35 +RF_Module +HOPERF_RFM9XW_SMD +Low Power Long Range Transceiver Module SMD-16 (https://www.hoperf.com/data/upload/portal/20181127/5bfcbea20e9ef.pdf) +LoRa Low Power Long Range Transceiver Module +0 +16 +16 +RF_Module +HOPERF_RFM9XW_THT +Low Power Long Range Transceiver Module THT-16 (https://www.hoperf.com/data/upload/portal/20181127/5bfcbea20e9ef.pdf) +Low Power Long Range Transceiver Module LoRa +0 +16 +16 +RF_Module +HOPERF_RFM69HW +Radio, RF, Module, http://www.hoperf.com/upload/rf/RFM69HW-V1.3.pdf +Radio RF Module +0 +16 +16 +RF_Module +IQRF_TRx2DA_KON-SIM-01 +8 pin SIM connector for IQRF TR-x2DA(T) modules, http://iqrf.org/weben/downloads.php?id=104 +IQRF_KON-SIM-01 IQRF_TRx2DA +0 +10 +8 +RF_Module +IQRF_TRx2D_KON-SIM-01 +8 pin SIM connector for IQRF TR-x2D(C)(T) modules, http://iqrf.org/weben/downloads.php?id=104 +IQRF_KON-SIM-01 IQRF_TRx2D IQRF_TRx2DC +0 +10 +8 +RF_Module +Laird_BL652 +Bluetooth v4.2 + NFC module +Bluetooth BLE NFC +0 +39 +39 +RF_Module +MOD-nRF8001 +BLE module, https://www.olimex.com/Products/Modules/RF/MOD-nRF8001/ +BLE module +0 +11 +11 +RF_Module +Microchip_RN4871 +Microchip RN4871 footprint +RN4871 BLE +0 +16 +16 +RF_Module +Modtronix_inAir9 +Modtronix Wireless SX1276 LoRa Module (http://modtronix.com/img/prod/imod/inair9/inair_dimensions.gif) +Modtronix LoRa inAir inAir9 SX1276 RF 915MHz 868MHz Wireless +0 +14 +14 +RF_Module +MonoWireless_TWE-L-WX +https://www.mono-wireless.com/jp/products/TWE-LITE/MW-PDS-TWELITE-JP.pdf +TWE-L-WX +0 +32 +32 +RF_Module +Particle_P1 +https://docs.particle.io/datasheets/p1-datasheet/ +Particle P1 +0 +75 +75 +RF_Module +RFDigital_RFD77101 +RFDigital RFD77101 Simblee +RFDigital RFD77101 Simblee +0 +48 +45 +RF_Module +RN42 +Class 2 Bluetooth Module with on-board antenna +Bluetooth Module +0 +36 +33 +RF_Module +RN42N +Class 2 Bluetooth Module without antenna +Bluetooth Module +0 +39 +36 +RF_Module +RN2483 +Low-Power Long Range LoRa Transceiver Module +rf module lora lorawan +0 +47 +47 +RF_Module +ST_SPBTLE +Bluetooth Low Energy Module +ble module st bluetooth +0 +11 +11 +RF_Module +TD1205 +https://github.com/Telecom-Design/Documentation_TD_RF_Module/blob/master/TD1205%20Datasheet.pdf +SIGFOX Module +0 +9 +9 +RF_Module +TD1208 +https://github.com/Telecom-Design/Documentation_TD_RF_Module/blob/master/TD1208%20Datasheet.pdf +SIGFOX Module +0 +25 +25 +RF_Module +Taiyo-Yuden_EYSGJNZWY +Taiyo Yuden NRF51822 Module Bluetooth https://www.yuden.co.jp/wireless_module/document/datareport2/en/TY_BLE_EYSGJNZ_DataReport_V1_9_20180530E.pdf +Taiyo Yuden NRF51822 Module Bluetooth +0 +30 +28 +RF_Module +ZETA-433-SO_SMD +RF transceiver SMD style https://www.rfsolutions.co.uk/downloads/1456219226DS-ZETA.pdf +RF transceiver SMD style +0 +12 +12 +RF_Module +ZETA-433-SO_THT +RF transceiver THT style https://www.rfsolutions.co.uk/downloads/1456219226DS-ZETA.pdf +RF transceiver SMD style +0 +12 +12 +RF_Module +nRF24L01_Breakout +nRF24L01 breakout board +nRF24L01 adapter breakout +0 +8 +8 +RF_Shielding +Laird_Technologies_97-2002_25.40x25.40mm +Laird Technologies 97-2002 EZ PEEL Shielding Cabinet One Piece SMD 25.40x25.40mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +8 +1 +RF_Shielding +Laird_Technologies_97-2003_12.70x13.37mm +Laird Technologies 97-2003 EZ PEEL Shielding Cabinet One Piece SMD 12.70x13.37mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +8 +1 +RF_Shielding +Laird_Technologies_BMI-S-101_13.66x12.70mm +Laird Technologies BMI-S-101 Shielding Cabinet One Piece SMD 13.66x12.70mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-102_16.50x16.50mm +Laird Technologies BMI-S-102 Shielding Cabinet One Piece SMD 16.50x16.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-103_26.21x26.21mm +Laird Technologies BMI-S-103 Shielding Cabinet One Piece SMD 26.21x26.21mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +24 +1 +RF_Shielding +Laird_Technologies_BMI-S-104_32.00x32.00mm +Laird Technologies BMI-S-104 Shielding Cabinet One Piece SMD 32.00x32.00mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-105_38.10x25.40mm +Laird Technologies BMI-S-105 Shielding Cabinet One Piece SMD 38.10x25.40mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-106_36.83x33.68mm +Laird Technologies BMI-S-106 Shielding Cabinet One Piece SMD 36.83x33.68mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-107_44.37x44.37mm +Laird Technologies BMI-S-107 Shielding Cabinet One Piece SMD 44.37x44.37mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +36 +1 +RF_Shielding +Laird_Technologies_BMI-S-201-F_13.66x12.70mm +Laird Technologies BMI-S-201-F Shielding Cabinet Two Piece SMD 13.66x12.70mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-202-F_16.50x16.50mm +Laird Technologies BMI-S-202-F Shielding Cabinet Two Piece SMD 16.50x16.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-203-F_26.21x26.21mm +Laird Technologies BMI-S-203-F Shielding Cabinet Two Piece SMD 26.21x26.21mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +24 +1 +RF_Shielding +Laird_Technologies_BMI-S-204-F_32.00x32.00mm +Laird Technologies BMI-S-204-F Shielding Cabinet Two Piece SMD 32.00x32.00mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-205-F_38.10x25.40mm +Laird Technologies BMI-S-205-F Shielding Cabinet Two Piece SMD 38.10x25.40mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-206-F_36.83x33.68mm +Laird Technologies BMI-S-206-F Shielding Cabinet Two Piece SMD 36.83x33.68mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-207-F_44.37x44.37mm +Laird Technologies BMI-S-207-F Shielding Cabinet Two Piece SMD 44.37x44.37mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +36 +1 +RF_Shielding +Laird_Technologies_BMI-S-208-F_39.60x39.60mm +Laird Technologies BMI-S-208-F Shielding Cabinet Two Piece SMD 39.60x39.60mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +32 +1 +RF_Shielding +Laird_Technologies_BMI-S-209-F_29.36x18.50mm +Laird Technologies BMI-S-209-F Shielding Cabinet Two Piece SMD 29.36x18.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +20 +1 +RF_Shielding +Laird_Technologies_BMI-S-210-F_44.00x30.50mm +Laird Technologies BMI-S-210-F Shielding Cabinet Two Piece SMD 44.00x30.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +32 +1 +RF_Shielding +Laird_Technologies_BMI-S-230-F_50.8x38.1mm +Laird Technologies BMI-S-230-F Shielding Cabinet Two Piece SMD 50.8x38.1mm +Shielding Cabinet +0 +36 +1 +RF_Shielding +Wuerth_36103205_20x20mm +WE-SHC Shielding Cabinet SMD 20x20mm +Shielding Cabinet +0 +20 +1 +RF_Shielding +Wuerth_36103255_25x25mm +WE-SHC Shielding Cabinet SMD 25x25mm +Shielding Cabinet +0 +24 +1 +RF_Shielding +Wuerth_36103305_30x30mm +WE-SHC Shielding Cabinet SMD 30x30mm +Shielding Cabinet +0 +28 +1 +RF_Shielding +Wuerth_36103505_50x50mm +WE-SHC Shielding Cabinet SMD 50x50mm +Shielding Cabinet +0 +44 +1 +RF_Shielding +Wuerth_36103605_60x60mm +WE-SHC Shielding Cabinet SMD 60x60mm +Shielding Cabinet +0 +52 +1 +RF_Shielding +Wuerth_36503205_20x20mm +WE-SHC Shielding Cabinet THT 21x21mm +Shielding Cabinet +0 +16 +1 +RF_Shielding +Wuerth_36503255_25x25mm +WE-SHC Shielding Cabinet THT 26x26mm +Shielding Cabinet +0 +20 +1 +RF_Shielding +Wuerth_36503305_30x30mm +WE-SHC Shielding Cabinet THT 31x31mm +Shielding Cabinet +0 +24 +1 +RF_Shielding +Wuerth_36503505_50x50mm +WE-SHC Shielding Cabinet THT 51x51mm +Shielding Cabinet +0 +40 +1 +RF_Shielding +Wuerth_36503605_60x60mm +WE-SHC Shielding Cabinet THT 61x61mm +Shielding Cabinet +0 +48 +1 +RF_WiFi +USR-C322 +https://www.usriot.com/download/WIFI/USR-C322-Hardware-Manual_V1.2.01.pdf +WiFi IEEE802.11 b/g/n +0 +44 +44 +Relay_SMD +Relay_DPDT_AXICOM_IMSeries_JLeg +http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7F108-98001%7FW5%7Fpdf%7FEnglish%7FENG_SS_108-98001_W5.pdf +AXICOM IM-Series Relay J JLeg +0 +8 +8 +Relay_SMD +Relay_DPDT_FRT5_SMD +IM Signal Relay DPDT FRT5 narrow footprint, SMD version of package +Relay DPDT IM-relay FRT5 +0 +10 +10 +Relay_SMD +Relay_DPDT_Kemet_EE2_NU +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double coil latching surface mount SMD +0 +8 +8 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUH +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double coil latching surface mount SMD +0 +8 +8 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUH_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching surface mount SMD +0 +10 +10 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUX_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching surface mount SMD +0 +10 +10 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUX_NKX +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double coil latching surface mount SMD +0 +8 +8 +Relay_SMD +Relay_DPDT_Kemet_EE2_NU_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching surface mount SMD +0 +10 +10 +Relay_SMD +Relay_DPDT_Omron_G6H-2F +package for Omron G6H-2F relais, see http://cdn-reichelt.de/documents/datenblatt/C300/G6H%23OMR.pdf +Omron G6H-2F relais +0 +10 +10 +Relay_SMD +Relay_DPDT_Omron_G6K-2F +Omron G6K-2F relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2F relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6K-2F-Y +Omron G6K-2F-Y relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2F-Y relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6K-2G +Omron G6K-2G relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2G relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6K-2G-Y +Omron G6K-2G-Y relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2G-Y relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6S-2F +Relay Omron G6S-2F, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6S-2F +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6S-2G +Relay Omron G6S-2G, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6S-2G +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6SK-2F +Relay Omron G6SK-2F, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6SK-2F +0 +10 +10 +Relay_SMD +Relay_DPDT_Omron_G6SK-2G +Relay Omron G6SK-2G, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6SK-2G +0 +10 +10 +Relay_SMD +Relay_Fujitsu_FTR-B3S +https://www.fujitsu.com/downloads/MICRO/fcai/relays/ftr-b3.pdf +Fujitsh FTR B3S B3SA Relay J JLeg +0 +8 +8 +Relay_SMD +Relay_SPDT_AXICOM_HF3Series_50ohms_Pitch1.27mm +hiqsdr.com/images/3/3e/Axicom-HF3.pdf +AXICOM HF3-Series Relay Pitch 1.27mm 50ohms +0 +16 +16 +Relay_SMD +Relay_SPDT_AXICOM_HF3Series_75ohms_Pitch1.27mm +hiqsdr.com/images/3/3e/Axicom-HF3.pdf +AXICOM HF3-Series Relay Pitch 1.27mm 75ohm +0 +16 +16 +Relay_THT +Relay_1-Form-A_Schrack-RYII_RM5mm +Relay, 1-Form-A, Schrack-RYII, RM5mm, SPST-NO +Relay 1-Form-A Schrack-RYII RM5mm SPST-NO +0 +4 +4 +Relay_THT +Relay_1-Form-B_Schrack-RYII_RM5mm +Relay, 1-Form-B, Schrack-RYII, RM5mm, SPST-NC +Relay 1-Form-B Schrack-RYII RM5mm SPST-NC +0 +4 +4 +Relay_THT +Relay_1-Form-C_Schrack-RYII_RM3.2mm +Relay, 1-Form-C, Schrack-RYII, RM3.2mm, SPDT +Relay 1-Form-C Schrack-RYII RM3.2mm SPDT +0 +5 +5 +Relay_THT +Relay_1P1T_NO_10x24x18.8mm_Panasonic_ADW11xxxxW_THT +Panasonic Relay SPST 10mm 24mm, https://www.panasonic-electric-works.com/pew/es/downloads/ds_dw_hl_en.pdf +Panasonic Relay SPST +0 +4 +4 +Relay_THT +Relay_DPDT_AXICOM_IMSeries_Pitch3.2mm +AXICOM IM-Series Relays, DPDR, Pitch 3.2mm, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7F108-98001%7FV%7Fpdf%7FEnglish%7FENG_SS_108-98001_V_IM_0614_v1.pdf%7F4-1462039-1 +AXICOM IM-Series Relay DPDR Pitch 3.2mm +0 +8 +8 +Relay_THT +Relay_DPDT_AXICOM_IMSeries_Pitch5.08mm +AXICOM IM-Series Relays, DPDR, Pitch 5.08 +AXICOM IM-Series Relay DPDR Pitch 5.08 +0 +8 +8 +Relay_THT +Relay_DPDT_FRT5 +IM Signal Relay DPDT FRT5 narrow footprint +Relay DPDT IM-relay FRT5 +0 +10 +10 +Relay_THT +Relay_DPDT_Finder_30.22 +Finder 32.21-x000 Relay, DPDT, https://gfinder.findernet.com/public/attachments/30/EN/S30EN.pdf +AXICOM IM-Series Relay SPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Finder_40.52 +Relay DPDT Finder 40.52, Pitch 5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.52 Pitch 5mm +0 +8 +8 +Relay_THT +Relay_DPDT_Fujitsu_FTR-F1C +https://www.fujitsu.com/downloads/MICRO/fcai/relays/ftr-f1.pdf +relay dpdt fujitsu tht +0 +8 +8 +Relay_THT +Relay_DPDT_Kemet_EC2 +Kemet signal relay, DPDT, non-latching, single coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT non single coil latching through hole THT +0 +8 +8 +Relay_THT +Relay_DPDT_Kemet_EC2_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching through hole THT +0 +10 +10 +Relay_THT +Relay_DPDT_Omron_G2RL +Omron Relay DPDT, https://omronfs.omron.com/en_US/ecb/products/pdf/en-g2rl.pdf +Omron Relay DPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G5V-2 +http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5v2.pdf +Omron G5V-2 Relay DPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6H-2 +Omron relay G6H-2, see http://cdn-reichelt.de/documents/datenblatt/C300/G6H%23OMR.pdf +Omron relay G6H-2 +0 +10 +10 +Relay_THT +Relay_DPDT_Omron_G6K-2P +Omron G6K-2P relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2P relay +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6K-2P-Y +Omron G6K-2P-Y relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2P-Y relay +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6S-2 +Relay Omron G6S-2, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6S-2 +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6SK-2 +Relay Omron G6SK-2, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6SK-2 +0 +10 +10 +Relay_THT +Relay_DPDT_Panasonic_JW2 +Panasonic Relay DPDT, http://www3.panasonic.biz/ac/e_download/control/relay/power/catalog/mech_eng_jw.pdf?via=ok +Panasonic Relay DPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Schrack-RT2-FormC-Dual-Coil_RM5mm +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Form C http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FRT2_bistable%7F1116%7Fpdf%7FEnglish%7FENG_DS_RT2_bistable_1116.pdf%7F1-1415537-8 +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Relay +0 +9 +9 +Relay_THT +Relay_DPDT_Schrack-RT2-FormC_RM5mm +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Form C http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=RT2_reflow&DocType=DS&DocLang=EN +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Relay +0 +8 +8 +Relay_THT +Relay_DPST_Fujitsu_FTR-F1A +https://www.fujitsu.com/downloads/MICRO/fcai/relays/ftr-f1.pdf +relay dpst fujitsu tht +0 +6 +6 +Relay_THT +Relay_DPST_Schrack-RT2-FormA_RM5mm +Relay DPST Schrack-RT2 RM5mm 16A 250V AC Form A http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=RT2_reflow&DocType=DS&DocLang=EN +Relay DPST Schrack-RT2 RM5mm 16A 250V AC Relay +0 +6 +6 +Relay_THT +Relay_SPDT_Finder_32.21-x000 +Finder 32.21-x000 Relay, SPDT, https://gfinder.findernet.com/assets/Series/355/S32EN.pdf +AXICOM IM-Series Relay SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_34.51_Horizontal +Relay SPDT, Finder Type34.51, horizontal form, see https://gfinder.findernet.com/public/attachments/34/EN/S34USAEN.pdf +Relay SPDT Finder +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_34.51_Vertical +Relay SPDT, Finder Type34.51, vertical/standing form, see https://gfinder.findernet.com/public/attachments/34/EN/S34USAEN.pdf +Relay SPDT Finder +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_36.11 +FINDER 36.11, SPDT relay, 10A, https://gfinder.findernet.com/public/attachments/36/EN/S36EN.pdf +spdt relay +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.11 +Relay SPDT Finder 40.11, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay SPDT Finder 40.11 +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.31 +Relay DPDT Finder 40.31, Pitch 3.5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.31 Pitch 3.5mm +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.41 +Relay DPDT Finder 40.41, Pitch 3.5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.41 Pitch 3.5mm +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.51 +Relay DPDT Finder 40.51, Pitch 5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.51 Pitch 5mm +0 +5 +5 +Relay_THT +Relay_SPDT_HJR-4102 +IM Signal Relay SPDT HJR-4102 +Relay SPDT IM-relay HJR-4102 +0 +6 +6 +Relay_THT +Relay_SPDT_HsinDa_Y14 +http://www.hsinda.com.cn/en/ProductShow.asp?ID=208 +Relay Y14 +0 +6 +6 +Relay_THT +Relay_SPDT_Omron-G5LE-1 +Omron Relay SPDT, http://www.omron.com/ecb/products/pdf/en-g5le.pdf +Omron Relay SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_Omron-G5Q-1 +Relay SPDT Omron Serie G5Q, http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5q.pdf +Relay SPDT Omron Serie G5Q +0 +5 +5 +Relay_THT +Relay_SPDT_Omron_G5V-1 +Relay Omron G5V-1, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5v_1.pdf +Relay Omron G5V-1 +0 +6 +6 +Relay_THT +Relay_SPDT_Omron_G6E +Relay SPDT Omron Serie G6E +Relay SPDT Omron Serie G6E 1x um +0 +5 +5 +Relay_THT +Relay_SPDT_Omron_G6EK +Relay SPDT Omron Serie G6EK, see http://www.logosfoundation.org/instrum_gwr/pi/Omron_G6E_134P.pdf +Relay SPDT Omron Serie G6EK +0 +6 +6 +Relay_THT +Relay_SPDT_Panasonic_JW1_FormC +Panasonic Relay SPDT, http://www3.panasonic.biz/ac/e_download/control/relay/power/catalog/mech_eng_jw.pdf?via=ok +Panasonic Relay SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_PotterBrumfield_T9AP5D52_12V30A +Relay SPDT Potter&Brumfield T9AP5D52 12V 30A 1xUn Connector Fast ON Only Dummy for Space NO Pads +Relay SPDT Potter&Brumfield T9AP5D52 12V 30A 1xUm Connector Fast ON Flachsteckeranschluss Only Dummy for Space NO Pads +0 +0 +0 +Relay_THT +Relay_SPDT_RAYEX-L90 +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90 SPDT +0 +6 +6 +Relay_THT +Relay_SPDT_RAYEX-L90S +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90S SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_SANYOU_SRD_Series_Form_C +relay Sanyou SRD series Form C http://www.sanyourelay.ca/public/products/pdf/SRD.pdf +relay Sanyu SRD form C +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RP-II-1-16A-FormC_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Form C http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Relay +0 +8 +5 +Relay_THT +Relay_SPDT_Schrack-RP-II-1-FormC_RM3.5mm +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RP-II-1-FormC_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RT1-16A-FormC_RM5mm +Relay SPST Schrack-RT1 RM5mm 16A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM5mm 16A 250V AC Relay +0 +8 +5 +Relay_THT +Relay_SPDT_Schrack-RT1-FormC_RM3.5mm +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RT1-FormC_RM5mm +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_StandexMeder_SIL_Form1C +Standex-Meder SIL-relais, Form 1C, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_SIL.pdf +Standex Meder SIL reed relais +0 +5 +5 +Relay_THT +Relay_SPST_Finder_32.21-x300 +Finder 32.21-x300 Relay, SPST, https://gfinder.findernet.com/assets/Series/355/S32EN.pdf +Finder 32.21-x300 Relay SPST +0 +4 +4 +Relay_THT +Relay_SPST_Omron-G5Q-1A +Relay SPST-NO Omron Serie G5Q, http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5q.pdf +Relay SPST-NO Omron Serie G5Q +0 +4 +4 +Relay_THT +Relay_SPST_Panasonic_JW1_FormA +Panasonic Relay SPST, http://www3.panasonic.biz/ac/e_download/control/relay/power/catalog/mech_eng_jw.pdf?via=ok +Panasonic Relay SPST +0 +4 +4 +Relay_THT +Relay_SPST_PotterBrumfield_T9AP1D52_12V30A +Relay SPST Potter&Brumfield T9AP1D52 12V 30A 1xEin Connector Fast ON Only Dummy for Space NO Pads +Relau SPST Potter&Brumfield T9AP1D52 12V 30A 1xEin Connector Fast ON Flachsteckeranschluss Only Dummy for Space NO Pads +0 +0 +0 +Relay_THT +Relay_SPST_RAYEX-L90A +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90A SPST NO +0 +5 +5 +Relay_THT +Relay_SPST_RAYEX-L90AS +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90AS SPST NO +0 +4 +4 +Relay_THT +Relay_SPST_RAYEX-L90B +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90B SPST NC +0 +5 +5 +Relay_THT +Relay_SPST_RAYEX-L90BS +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90BS SPST NC +0 +4 +4 +Relay_THT +Relay_SPST_SANYOU_SRD_Series_Form_A +relay Sanyou SRD series Form A http://www.sanyourelay.ca/public/products/pdf/SRD.pdf +relay Sanyu SRD form A +0 +4 +4 +Relay_THT +Relay_SPST_SANYOU_SRD_Series_Form_B +relay Sanyou SRD series Form B opener http://www.sanyourelay.ca/public/products/pdf/SRD.pdf +relay Sanyu SRD form B opener +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RP-II-1-16A-FormA_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Form A http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Relay +0 +6 +4 +Relay_THT +Relay_SPST_Schrack-RP-II-1-FormA_RM3.5mm +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Form A +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RP-II-1-FormA_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Form A http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RP3SL-1coil_RM5mm +Relay SPST Schrack-RP3SL, 1-coil-version, RM5mm 16A 250V AC Form A http://www.alliedelec.com/m/d/543c6bed18bf23a83ae5238947033ee0.pdf +Relay SPST Schrack-RP3SL RM5mm 16A 250V AC Relay +0 +6 +4 +Relay_THT +Relay_SPST_Schrack-RP3SL_RM5mm +Relay SPST Schrack-RP3SL RM5mm 16A 250V AC Form A http://www.alliedelec.com/m/d/543c6bed18bf23a83ae5238947033ee0.pdf +Relay SPST Schrack-RP3SL RM5mm 16A 250V AC Relay +0 +7 +5 +Relay_THT +Relay_SPST_Schrack-RT1-16A-FormA_RM5mm +Relay SPST Schrack-RT2 RM5mm 16A 250V AC Form C http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=RT2_reflow&DocType=DS&DocLang=EN +Relay SPST Schrack-RT2 RM5mm 16A 250V AC Relay +0 +6 +4 +Relay_THT +Relay_SPST_Schrack-RT1-FormA_RM3.5mm +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Form A +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RT1-FormA_RM5mm +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_StandexMeder_MS_Form1AB +Standex-Meder MS SIL-relais, Form 1A/1B, see https://standexelectronics.com/de/produkte/ms-reed-relais/ +Standex Meder MS SIL reed relais +0 +4 +4 +Relay_THT +Relay_SPST_StandexMeder_SIL_Form1A +Standex-Meder SIL-relais, Form 1A, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_SIL.pdf +Standex Meder SIL reed relais +0 +4 +4 +Relay_THT +Relay_SPST_StandexMeder_SIL_Form1B +Standex-Meder SIL-relais, Form 1B, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_SIL.pdf +Standex Meder SIL reed relais +0 +4 +4 +Relay_THT +Relay_SPST_TE_PCH-1xxx2M +Miniature PCB Relay, PCH Series, 1 Form A (NO), SPST http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FPCH_series_relay_data_sheet_E%7F1215%7Fpdf%7FEnglish%7FENG_DS_PCH_series_relay_data_sheet_E_1215.pdf +Relay SPST NO +0 +4 +4 +Relay_THT +Relay_SPST_TE_PCN-1xxD3MHZ +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1461491%7FG2%7Fpdf%7FEnglish%7FENG_CD_1461491_G2.pdf%7F3-1461491-0 +SPST relay slim +0 +4 +4 +Relay_THT +Relay_Socket_DPDT_Finder_96.12 +https://gfinder.findernet.com/public/attachments/56/DE/S56DE.pdf +Relay socket DPDT Finder 96.12 56.32 +0 +8 +8 +Relay_THT +Relay_StandexMeder_DIP_HighProfile +package for Standex Meder DIP reed relay series, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_DIP.pdf +DIL DIP PDIP 2.54mm 7.62mm 300mil reed relay +0 +8 +8 +Relay_THT +Relay_StandexMeder_DIP_LowProfile +package for Standex Meder DIP reed relay series, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_DIP.pdf +DIL DIP PDIP 2.54mm 7.62mm 300mil reed relay +0 +8 +8 +Relay_THT +Relay_StandexMeder_UMS +Standex-Meder SIL-relais, UMS, see http://cdn-reichelt.de/documents/datenblatt/C300/UMS05_1A80_75L_DB.pdf +Standex Meder SIL reed relais +0 +4 +4 +Resistor_SMD +R_0201_0603Metric +Resistor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +resistor +0 +4 +2 +Resistor_SMD +R_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Resistor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +4 +2 +Resistor_SMD +R_0402_1005Metric +Resistor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0402_1005Metric_Pad0.72x0.64mm_HandSolder +Resistor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0603_1608Metric +Resistor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0603_1608Metric_Pad0.98x0.95mm_HandSolder +Resistor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0612_1632Metric +Resistor SMD 0612 (1632 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0612_1632Metric_Pad1.18x3.40mm_HandSolder +Resistor SMD 0612 (1632 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0805_2012Metric +Resistor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0805_2012Metric_Pad1.20x1.40mm_HandSolder +Resistor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0815_2038Metric +Resistor SMD 0815 (2038 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.susumu.co.jp/common/pdf/n_catalog_partition07_en.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0815_2038Metric_Pad1.20x4.05mm_HandSolder +Resistor SMD 0815 (2038 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.susumu.co.jp/common/pdf/n_catalog_partition07_en.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_01005_0402Metric +Resistor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +resistor +0 +4 +2 +Resistor_SMD +R_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Resistor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +4 +2 +Resistor_SMD +R_1020_2550Metric +Resistor SMD 1020 (2550 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1020_2550Metric_Pad1.33x5.20mm_HandSolder +Resistor SMD 1020 (2550 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1206_3216Metric +Resistor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1206_3216Metric_Pad1.30x1.75mm_HandSolder +Resistor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1210_3225Metric +Resistor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1210_3225Metric_Pad1.30x2.65mm_HandSolder +Resistor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1218_3246Metric +Resistor SMD 1218 (3246 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20035/dcrcwe3.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1218_3246Metric_Pad1.22x4.75mm_HandSolder +Resistor SMD 1218 (3246 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20035/dcrcwe3.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1812_4532Metric +Resistor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Resistor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_2010_5025Metric +Resistor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_2010_5025Metric_Pad1.40x2.65mm_HandSolder +Resistor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_2512_6332Metric +Resistor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_2512_6332Metric_Pad1.40x3.35mm_HandSolder +Resistor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_2816_7142Metric +Resistor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Resistor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_4020_10251Metric +Resistor SMD 4020 (10251 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://datasheet.octopart.com/HVC0603T5004FET-Ohmite-datasheet-26699797.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_4020_10251Metric_Pad1.65x5.30mm_HandSolder +Resistor SMD 4020 (10251 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://datasheet.octopart.com/HVC0603T5004FET-Ohmite-datasheet-26699797.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_Array_Concave_2x0603 +Thick Film Chip Resistor Array, Wave soldering, Vishay CRA06P (see cra06p.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Concave_4x0402 +Thick Film Chip Resistor Array, Wave soldering, Vishay CRA04P (see cra04p.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Concave_4x0603 +Thick Film Chip Resistor Array, Wave soldering, Vishay CRA06P (see cra06p.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_2x0402 +Chip Resistor Network, ROHM MNR02 (see mnr_g.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_2x0603 +Chip Resistor Network, ROHM MNR12 (see mnr_g.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_2x0606 +Precision Thin Film Chip Resistor Array, VISHAY (see http://www.vishay.com/docs/28770/acasat.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_2x1206 +Chip Resistor Network, ROHM MNR32 (see mnr_g.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_4x0402 +Chip Resistor Network, ROHM MNR04 (see mnr_g.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_4x0603 +Chip Resistor Network, ROHM MNR14 (see mnr_g.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_4x0612 +Precision Thin Film Chip Resistor Array, VISHAY (see http://www.vishay.com/docs/28770/acasat.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_4x1206 +Chip Resistor Network, ROHM MNR34 (see mnr_g.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_5x0603 +Chip Resistor Network, ROHM MNR15 (see mnr_g.pdf) +resistor array +0 +10 +10 +Resistor_SMD +R_Array_Convex_5x1206 +Chip Resistor Network, ROHM MNR35 (see mnr_g.pdf) +resistor array +0 +10 +10 +Resistor_SMD +R_Array_Convex_8x0602 +Chip Resistor Network, ROHM MNR18 (see mnr_g.pdf) +resistor array +0 +16 +16 +Resistor_SMD +R_Cat16-2 +SMT resistor net, Bourns CAT16 series, 2 way +SMT resistor net Bourns CAT16 series 2 way +0 +4 +4 +Resistor_SMD +R_Cat16-4 +SMT resistor net, Bourns CAT16 series, 4 way +SMT resistor net Bourns CAT16 series 4 way +0 +8 +8 +Resistor_SMD +R_Cat16-8 +SMT resistor net, Bourns CAT16 series, 8 way +SMT resistor net Bourns CAT16 series 8 way +0 +16 +16 +Resistor_SMD +R_MELF_MMB-0207 +Resistor, MELF, MMB-0207, http://www.vishay.com/docs/28713/melfprof.pdf +MELF Resistor +0 +2 +2 +Resistor_SMD +R_MicroMELF_MMU-0102 +Resistor, MicroMELF, MMU-0102, http://www.vishay.com/docs/28713/melfprof.pdf +MicroMELF Resistor +0 +2 +2 +Resistor_SMD +R_MiniMELF_MMA-0204 +Resistor, MiniMELF, MMA-0204, http://www.vishay.com/docs/28713/melfprof.pdf +MiniMELF Resistor +0 +2 +2 +Resistor_SMD +R_Shunt_Ohmite_LVK12 +4 contact shunt resistor +shunt resistor 4 contacts +0 +4 +4 +Resistor_SMD +R_Shunt_Ohmite_LVK20 +4 contacts shunt resistor, https://www.ohmite.com/assets/docs/res_lvk.pdf +4 contacts resistor smd +0 +4 +4 +Resistor_SMD +R_Shunt_Ohmite_LVK24 +4 contacts shunt resistor,https://www.ohmite.com/assets/docs/res_lvk.pdf +4 contacts resistor smd +0 +4 +4 +Resistor_SMD +R_Shunt_Ohmite_LVK25 +4 contacts shunt resistor,https://www.ohmite.com/assets/docs/res_lvk.pdf +4 contacts resistor smd +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSK2512_6332Metric_T1.19mm +Shunt Resistor SMD 2512 (6332 Metric), 2.6mm thick, Vishay WKS2512, Terminal length (T) 1.19mm, 5 to 200 milli Ohm (http://http://www.vishay.com/docs/30108/wsk.pdf) +resistor shunt WSK2512 +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSK2512_6332Metric_T2.21mm +Shunt Resistor SMD 2512 (6332 Metric), 2.6mm thick, Vishay WKS2512, Terminal length (T) 2.21mm, 1 to 4.9 milli Ohm (http://http://www.vishay.com/docs/30108/wsk.pdf) +resistor shunt WSK2512 +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSK2512_6332Metric_T2.66mm +Shunt Resistor SMD 2512 (6332 Metric), 2.6mm thick, Vishay WKS2512, Terminal length (T) 2.66mm, 0.5 to 0.99 milli Ohm (http://http://www.vishay.com/docs/30108/wsk.pdf) +resistor shunt WSK2512 +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSKW0612 +https://www.vishay.com/docs/30332/wskw0612.pdf +4-Terminal SMD Shunt +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSR2_WSR3 +Power Metal Strip Resistors 0.005 to 0.2, https://www.vishay.com/docs/30101/wsr.pdf +SMD Shunt Resistor +0 +2 +2 +Resistor_SMD +R_Shunt_Vishay_WSR2_WSR3_KelvinConnection +Power Metal Strip Resistors 0.005 to 0.2, https://www.vishay.com/docs/30101/wsr.pdf +SMD Shunt Resistor +0 +4 +2 +Resistor_THT +R_Array_SIP4 +4-pin Resistor SIP pack +R +0 +4 +4 +Resistor_THT +R_Array_SIP5 +5-pin Resistor SIP pack +R +0 +5 +5 +Resistor_THT +R_Array_SIP6 +6-pin Resistor SIP pack +R +0 +6 +6 +Resistor_THT +R_Array_SIP7 +7-pin Resistor SIP pack +R +0 +7 +7 +Resistor_THT +R_Array_SIP8 +8-pin Resistor SIP pack +R +0 +8 +8 +Resistor_THT +R_Array_SIP9 +9-pin Resistor SIP pack +R +0 +9 +9 +Resistor_THT +R_Array_SIP10 +10-pin Resistor SIP pack +R +0 +10 +10 +Resistor_THT +R_Array_SIP11 +11-pin Resistor SIP pack +R +0 +11 +11 +Resistor_THT +R_Array_SIP12 +12-pin Resistor SIP pack +R +0 +12 +12 +Resistor_THT +R_Array_SIP13 +13-pin Resistor SIP pack +R +0 +13 +13 +Resistor_THT +R_Array_SIP14 +14-pin Resistor SIP pack +R +0 +14 +14 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P1.90mm_Vertical +Resistor, Axial_DIN0204 series, Axial, Vertical, pin pitch=1.9mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Vertical pin pitch 1.9mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P2.54mm_Vertical +Resistor, Axial_DIN0204 series, Axial, Vertical, pin pitch=2.54mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Vertical pin pitch 2.54mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P5.08mm_Horizontal +Resistor, Axial_DIN0204 series, Axial, Horizontal, pin pitch=5.08mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Horizontal pin pitch 5.08mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P5.08mm_Vertical +Resistor, Axial_DIN0204 series, Axial, Vertical, pin pitch=5.08mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Vertical pin pitch 5.08mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P7.62mm_Horizontal +Resistor, Axial_DIN0204 series, Axial, Horizontal, pin pitch=7.62mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Horizontal pin pitch 7.62mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P2.54mm_Vertical +Resistor, Axial_DIN0207 series, Axial, Vertical, pin pitch=2.54mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Vertical pin pitch 2.54mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P5.08mm_Vertical +Resistor, Axial_DIN0207 series, Axial, Vertical, pin pitch=5.08mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Vertical pin pitch 5.08mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P7.62mm_Horizontal +Resistor, Axial_DIN0207 series, Axial, Horizontal, pin pitch=7.62mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Horizontal pin pitch 7.62mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal +Resistor, Axial_DIN0207 series, Axial, Horizontal, pin pitch=10.16mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Horizontal pin pitch 10.16mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P15.24mm_Horizontal +Resistor, Axial_DIN0207 series, Axial, Horizontal, pin pitch=15.24mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Horizontal pin pitch 15.24mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P2.54mm_Vertical +Resistor, Axial_DIN0309 series, Axial, Vertical, pin pitch=2.54mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Vertical pin pitch 2.54mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P5.08mm_Vertical +Resistor, Axial_DIN0309 series, Axial, Vertical, pin pitch=5.08mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Vertical pin pitch 5.08mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P12.70mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=12.7mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 12.7mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P15.24mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=15.24mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 15.24mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P20.32mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=20.32mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 20.32mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P25.40mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=25.4mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 25.4mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P5.08mm_Vertical +Resistor, Axial_DIN0411 series, Axial, Vertical, pin pitch=5.08mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Vertical pin pitch 5.08mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P7.62mm_Vertical +Resistor, Axial_DIN0411 series, Axial, Vertical, pin pitch=7.62mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Vertical pin pitch 7.62mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P12.70mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=12.7mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 12.7mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P15.24mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=15.24mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 15.24mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P20.32mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=20.32mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 20.32mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P25.40mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=25.4mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 25.4mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P5.08mm_Vertical +Resistor, Axial_DIN0414 series, Axial, Vertical, pin pitch=5.08mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Vertical pin pitch 5.08mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P7.62mm_Vertical +Resistor, Axial_DIN0414 series, Axial, Vertical, pin pitch=7.62mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Vertical pin pitch 7.62mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P15.24mm_Horizontal +Resistor, Axial_DIN0414 series, Axial, Horizontal, pin pitch=15.24mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Horizontal pin pitch 15.24mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P20.32mm_Horizontal +Resistor, Axial_DIN0414 series, Axial, Horizontal, pin pitch=20.32mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Horizontal pin pitch 20.32mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P25.40mm_Horizontal +Resistor, Axial_DIN0414 series, Axial, Horizontal, pin pitch=25.4mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Horizontal pin pitch 25.4mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P5.08mm_Vertical +Resistor, Axial_DIN0516 series, Axial, Vertical, pin pitch=5.08mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Vertical pin pitch 5.08mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0516 series, Axial, Vertical, pin pitch=7.62mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Vertical pin pitch 7.62mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P20.32mm_Horizontal +Resistor, Axial_DIN0516 series, Axial, Horizontal, pin pitch=20.32mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Horizontal pin pitch 20.32mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0516 series, Axial, Horizontal, pin pitch=25.4mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Horizontal pin pitch 25.4mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0516 series, Axial, Horizontal, pin pitch=30.48mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Horizontal pin pitch 30.48mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P5.08mm_Vertical +Resistor, Axial_DIN0614 series, Axial, Vertical, pin pitch=5.08mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Vertical pin pitch 5.08mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P7.62mm_Vertical +Resistor, Axial_DIN0614 series, Axial, Vertical, pin pitch=7.62mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Vertical pin pitch 7.62mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P15.24mm_Horizontal +Resistor, Axial_DIN0614 series, Axial, Horizontal, pin pitch=15.24mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Horizontal pin pitch 15.24mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P20.32mm_Horizontal +Resistor, Axial_DIN0614 series, Axial, Horizontal, pin pitch=20.32mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Horizontal pin pitch 20.32mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P25.40mm_Horizontal +Resistor, Axial_DIN0614 series, Axial, Horizontal, pin pitch=25.4mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Horizontal pin pitch 25.4mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P5.08mm_Vertical +Resistor, Axial_DIN0617 series, Axial, Vertical, pin pitch=5.08mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Vertical pin pitch 5.08mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0617 series, Axial, Vertical, pin pitch=7.62mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Vertical pin pitch 7.62mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P20.32mm_Horizontal +Resistor, Axial_DIN0617 series, Axial, Horizontal, pin pitch=20.32mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Horizontal pin pitch 20.32mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0617 series, Axial, Horizontal, pin pitch=25.4mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Horizontal pin pitch 25.4mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0617 series, Axial, Horizontal, pin pitch=30.48mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Horizontal pin pitch 30.48mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0918 series, Axial, Vertical, pin pitch=7.62mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Vertical pin pitch 7.62mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P22.86mm_Horizontal +Resistor, Axial_DIN0918 series, Axial, Horizontal, pin pitch=22.86mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Horizontal pin pitch 22.86mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0918 series, Axial, Horizontal, pin pitch=25.4mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Horizontal pin pitch 25.4mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0918 series, Axial, Horizontal, pin pitch=30.48mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Horizontal pin pitch 30.48mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0922_L20.0mm_D9.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0922 series, Axial, Vertical, pin pitch=7.62mm, 5W, length*diameter=20*9mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0922 series Axial Vertical pin pitch 7.62mm 5W length 20mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0922_L20.0mm_D9.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0922 series, Axial, Horizontal, pin pitch=25.4mm, 5W, length*diameter=20*9mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0922 series Axial Horizontal pin pitch 25.4mm 5W length 20mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0922_L20.0mm_D9.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0922 series, Axial, Horizontal, pin pitch=30.48mm, 5W, length*diameter=20*9mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0922 series Axial Horizontal pin pitch 30.48mm 5W length 20mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P5.08mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=5.08mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 5.08mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P7.62mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=7.62mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 7.62mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P22.40mm +Resistor, Axial_Power series, Box, pin pitch=22.4mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 22.4mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P25.40mm +Resistor, Axial_Power series, Box, pin pitch=25.4mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 25.4mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P30.48mm +Resistor, Axial_Power series, Box, pin pitch=30.48mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 30.48mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W6.4mm_P27.94mm +Resistor, Axial_Power series, Box, pin pitch=27.94mm, 5W, length*width*height=25*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 27.94mm 5W length 25mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W6.4mm_P30.48mm +Resistor, Axial_Power series, Box, pin pitch=30.48mm, 5W, length*width*height=25*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 30.48mm 5W length 25mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P7.62mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=7.62mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 7.62mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P10.16mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=10.16mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 10.16mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P27.94mm +Resistor, Axial_Power series, Box, pin pitch=27.94mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 27.94mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P30.48mm +Resistor, Axial_Power series, Box, pin pitch=30.48mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 30.48mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W6.4mm_P40.64mm +Resistor, Axial_Power series, Box, pin pitch=40.64mm, 7W, length*width*height=38*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 40.64mm 7W length 38mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W6.4mm_P45.72mm +Resistor, Axial_Power series, Box, pin pitch=45.72mm, 7W, length*width*height=38*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 45.72mm 7W length 38mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W9.0mm_P40.64mm +Resistor, Axial_Power series, Box, pin pitch=40.64mm, 9W, length*width*height=38*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 40.64mm 9W length 38mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W9.0mm_P45.72mm +Resistor, Axial_Power series, Box, pin pitch=45.72mm, 9W, length*width*height=38*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 45.72mm 9W length 38mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P7.62mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=7.62mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 7.62mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P10.16mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=10.16mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 10.16mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P55.88mm +Resistor, Axial_Power series, Box, pin pitch=55.88mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 55.88mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P60.96mm +Resistor, Axial_Power series, Box, pin pitch=60.96mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 60.96mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L50.0mm_W9.0mm_P55.88mm +Resistor, Axial_Power series, Box, pin pitch=55.88mm, 11W, length*width*height=50*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 55.88mm 11W length 50mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L50.0mm_W9.0mm_P60.96mm +Resistor, Axial_Power series, Box, pin pitch=60.96mm, 11W, length*width*height=50*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 60.96mm 11W length 50mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L60.0mm_W14.0mm_P10.16mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=10.16mm, 25W, length*width*height=60*14*14mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 10.16mm 25W length 60mm width 14mm height 14mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L60.0mm_W14.0mm_P66.04mm +Resistor, Axial_Power series, Box, pin pitch=66.04mm, 25W, length*width*height=60*14*14mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 66.04mm 25W length 60mm width 14mm height 14mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L60.0mm_W14.0mm_P71.12mm +Resistor, Axial_Power series, Box, pin pitch=71.12mm, 25W, length*width*height=60*14*14mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 71.12mm 25W length 60mm width 14mm height 14mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L75.0mm_W9.0mm_P81.28mm +Resistor, Axial_Power series, Box, pin pitch=81.28mm, 17W, length*width*height=75*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 81.28mm 17W length 75mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L75.0mm_W9.0mm_P86.36mm +Resistor, Axial_Power series, Box, pin pitch=86.36mm, 17W, length*width*height=75*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 86.36mm 17W length 75mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Shunt_L22.2mm_W8.0mm_PS14.30mm_P25.40mm +Resistor, Axial_Shunt series, Box, pin pitch=25.4mm, 3W, length*width*height=22.2*8*8mm^3, shunt pin pitch = 14.30mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 25.4mm 3W length 22.2mm width 8mm height 8mm shunt pin pitch 14.30mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L22.2mm_W9.5mm_PS14.30mm_P25.40mm +Resistor, Axial_Shunt series, Box, pin pitch=25.4mm, 5W, length*width*height=22.2*9.5*9.5mm^3, shunt pin pitch = 14.30mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 25.4mm 5W length 22.2mm width 9.5mm height 9.5mm shunt pin pitch 14.30mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L35.3mm_W9.5mm_PS25.40mm_P38.10mm +Resistor, Axial_Shunt series, Box, pin pitch=38.1mm, 7W, length*width*height=35.3*9.5*9.5mm^3, shunt pin pitch = 25.40mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 38.1mm 7W length 35.3mm width 9.5mm height 9.5mm shunt pin pitch 25.40mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L47.6mm_W9.5mm_PS34.93mm_P50.80mm +Resistor, Axial_Shunt series, Box, pin pitch=50.8mm, 10W, length*width*height=47.6*9.5*9.5mm^3, shunt pin pitch = 34.93mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 50.8mm 10W length 47.6mm width 9.5mm height 9.5mm shunt pin pitch 34.93mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L47.6mm_W12.7mm_PS34.93mm_P50.80mm +Resistor, Axial_Shunt series, Box, pin pitch=50.8mm, 15W, length*width*height=47.6*12.7*12.7mm^3, shunt pin pitch = 34.93mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 50.8mm 15W length 47.6mm width 12.7mm height 12.7mm shunt pin pitch 34.93mm +0 +4 +4 +Resistor_THT +R_Bare_Metal_Element_L12.4mm_W4.8mm_P11.40mm +Resistor, Bare_Metal_Element series, Bare Metal Strip/Wire, Horizontal, pin pitch=11.4mm, 1W, length*width=12.4*4.8mm^2, https://www.bourns.com/pdfs/PWR4412-2S.pdf +Resistor Bare_Metal_Element series Bare Metal Strip Wire Horizontal pin pitch 11.4mm 1W length 12.4mm width 4.8mm +0 +2 +2 +Resistor_THT +R_Bare_Metal_Element_L16.3mm_W4.8mm_P15.30mm +Resistor, Bare_Metal_Element series, Bare Metal Strip/Wire, Horizontal, pin pitch=15.3mm, 3W, length*width=16.3*4.8mm^2, https://www.bourns.com/pdfs/PWR4412-2S.pdf +Resistor Bare_Metal_Element series Bare Metal Strip Wire Horizontal pin pitch 15.3mm 3W length 16.3mm width 4.8mm +0 +2 +2 +Resistor_THT +R_Bare_Metal_Element_L21.3mm_W4.8mm_P20.30mm +Resistor, Bare_Metal_Element series, Bare Metal Strip/Wire, Horizontal, pin pitch=20.3mm, 5W, length*width=21.3*4.8mm^2, https://www.bourns.com/pdfs/PWR4412-2S.pdf +Resistor Bare_Metal_Element series Bare Metal Strip Wire Horizontal pin pitch 20.3mm 5W length 21.3mm width 4.8mm +0 +2 +2 +Resistor_THT +R_Box_L8.4mm_W2.5mm_P5.08mm +Resistor, Box series, Radial, pin pitch=5.08mm, 0.5W = 1/2W, length*width=8.38*2.54mm^2, http://www.vishay.com/docs/60051/cns020.pdf +Resistor Box series Radial pin pitch 5.08mm 0.5W = 1/2W length 8.38mm width 2.54mm +0 +2 +2 +Resistor_THT +R_Box_L13.0mm_W4.0mm_P9.00mm +Resistor, Box series, Radial, pin pitch=9.00mm, 2W, length*width=13.0*4.0mm^2, http://www.produktinfo.conrad.com/datenblaetter/425000-449999/443860-da-01-de-METALLBAND_WIDERSTAND_0_1_OHM_5W_5Pr.pdf +Resistor Box series Radial pin pitch 9.00mm 2W length 13.0mm width 4.0mm +0 +2 +2 +Resistor_THT +R_Box_L14.0mm_W5.0mm_P9.00mm +Resistor, Box series, Radial, pin pitch=9.00mm, 5W, length*width=14.0*5.0mm^2, http://www.produktinfo.conrad.com/datenblaetter/425000-449999/443860-da-01-de-METALLBAND_WIDERSTAND_0_1_OHM_5W_5Pr.pdf +Resistor Box series Radial pin pitch 9.00mm 5W length 14.0mm width 5.0mm +0 +2 +2 +Resistor_THT +R_Box_L26.0mm_W5.0mm_P20.00mm +Resistor, Box series, Radial, pin pitch=20.00mm, 10W, length*width=26.0*5.0mm^2, http://www.produktinfo.conrad.com/datenblaetter/425000-449999/443860-da-01-de-METALLBAND_WIDERSTAND_0_1_OHM_5W_5Pr.pdf +Resistor Box series Radial pin pitch 20.00mm 10W length 26.0mm width 5.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L7.0mm_W8.0mm_Px2.40mm_Py2.30mm +Resistor, Radial_Power series, Radial, pin pitch=2.40*2.30mm^2, 7W, length*width=7*8mm^2, http://www.vitrohm.com/content/files/vitrohm_series_kv_-_201601.pdf +Resistor Radial_Power series Radial pin pitch 2.40*2.30mm^2 7W length 7mm width 8mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L9.0mm_W10.0mm_Px2.70mm_Py2.30mm +Resistor, Radial_Power series, Radial, pin pitch=2.70*2.30mm^2, 17W, length*width=9*10mm^2, http://www.vitrohm.com/content/files/vitrohm_series_kv_-_201601.pdf +Resistor Radial_Power series Radial pin pitch 2.70*2.30mm^2 17W length 9mm width 10mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L11.0mm_W7.0mm_P5.00mm +Resistor, Radial_Power series, Radial, pin pitch=5.00mm, 2W, length*width=11.0*7.0mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 5.00mm 2W length 11.0mm width 7.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L12.0mm_W8.0mm_P5.00mm +Resistor, Radial_Power series, Radial, pin pitch=5.00mm, 3W, length*width=12.0*8.0mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 5.00mm 3W length 12.0mm width 8.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L13.0mm_W9.0mm_P5.00mm +Resistor, Radial_Power series, Radial, pin pitch=5.00mm, 7W, length*width=13.0*9.0mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 5.00mm 7W length 13.0mm width 9.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L16.1mm_W9.0mm_P7.37mm +Resistor, Radial_Power series, Radial, pin pitch=7.37mm, 10W, length*width=16.1*9mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 7.37mm 10W length 16.1mm width 9mm +0 +2 +2 +Rotary_Encoder +RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm +Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E... with switch, vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC11E_Vertical_H20mm +Alps rotary encoder, EC12E... without switch (pins are dummy), vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +4 +Rotary_Encoder +RotaryEncoder_Alps_EC11E_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E... without switch (pins are dummy), vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +4 +Rotary_Encoder +RotaryEncoder_Alps_EC12E-Switch_Vertical_H20mm +Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html & http://cdn-reichelt.de/documents/datenblatt/F100/402097STEC12E08.PDF +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC12E-Switch_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E... with switch, vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html & http://cdn-reichelt.de/documents/datenblatt/F100/402097STEC12E08.PDF +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC12E_Vertical_H20mm +Alps rotary encoder, EC12E..., vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html +rotary encoder +0 +5 +4 +Rotary_Encoder +RotaryEncoder_Alps_EC12E_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E..., vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html +rotary encoder +0 +5 +4 +Sensor +Aosong_DHT11_5.5x12.0_P2.54mm +Temperature and humidity module, http://akizukidenshi.com/download/ds/aosong/DHT11.pdf +Temperature and humidity module +0 +4 +4 +Sensor +MQ-6 +Gas Sensor, 6 pin, https://www.winsen-sensor.com/d/files/semiconductor/mq-6.pdf +gas sensor +0 +6 +6 +Sensor +SHT1x +SHT1x +SHT1x +0 +8 +8 +Sensor_Audio +CUI_CMC-4013-SMT +Omnidirectional, -42dB, reflowable, electret condenser microphone https://www.cuidevices.com/product/resource/cmc-4013-smt-tr.pdf +Microphone CUI +0 +2 +2 +Sensor_Audio +Infineon_PG-LLGA-5-1 +Infineon_PG-LLGA-5-1 StepUp generated footprint, https://www.infineon.com/cms/en/product/packages/PG-LLGA/PG-LLGA-5-1/ +infineon mems microphone +0 +15 +5 +Sensor_Audio +ST_HLGA-6_3.76x4.72mm_P1.65mm +http://www.st.com/content/ccc/resource/technical/document/datasheet/group3/27/62/48/98/44/54/4d/36/DM00303211/files/DM00303211.pdf/jcr:content/translations/en.DM00303211.pdf +HLGA Sensor Audio +0 +6 +6 +Sensor_Current +AKM_CQ_7 +AKM Current Sensor, 7 pin, THT (http://www.akm.com/akm/en/file/datasheet/CQ-236B.pdf) +akm current sensor tht +0 +39 +7 +Sensor_Current +AKM_CQ_7S +AKM Current Sensor, 7 pin, SMD (http://www.akm.com/akm/en/file/datasheet/CQ-236B.pdf) +akm current sensor smd +0 +19 +7 +Sensor_Current +AKM_CQ_VSOP-24_5.6x7.9mm_P0.65mm +AKM VSOP-24 current sensor, 5.6x7.9mm body, 0.65mm pitch (http://www.akm.com/akm/en/file/datasheet/CQ-330J.pdf) +akm vsop 24 +0 +10 +10 +Sensor_Current +AKM_CZ_SSOP-10_6.5x8.1mm_P0.95mm +AKM CZ-381x current sensor, 6.5x8.1mm body, 0.95mm pitch (http://www.akm.com/akm/en/product/detail/0009/) +akm cz-381x 10 +0 +10 +10 +Sensor_Current +Allegro_CB_PFF +Allegro MicroSystems, CB-PFF Package (http://www.allegromicro.com/en/Products/Current-Sensor-ICs/Fifty-To-Two-Hundred-Amp-Integrated-Conductor-Sensor-ICs/ACS758.aspx) !PADS 4-5 DO NOT MATCH DATASHEET! +Allegro CB-PFF +0 +37 +5 +Sensor_Current +Allegro_CB_PSF +Allegro MicroSystems, CB-PSF Package (http://www.allegromicro.com/en/Products/Current-Sensor-ICs/Fifty-To-Two-Hundred-Amp-Integrated-Conductor-Sensor-ICs/ACS758.aspx) +Allegro CB-PSF +0 +5 +5 +Sensor_Current +Allegro_CB_PSS +Allegro MicroSystems, CB-PSS Package (http://www.allegromicro.com/en/Products/Current-Sensor-ICs/Fifty-To-Two-Hundred-Amp-Integrated-Conductor-Sensor-ICs/ACS758.aspx) +Allegro CB-PSS +0 +5 +5 +Sensor_Current +Allegro_PSOF-7_4.8x6.4mm_P1.60mm +Allegro Microsystems PSOF-7, 4.8x6.4mm Body, 1.60mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/ACS780-Datasheet.ashx) +Allegro PSOF-7 +0 +7 +7 +Sensor_Current +Allegro_QFN-12-10-1EP_3x3mm_P0.5mm +Allegro Microsystems 12-Lead (10-Lead Populated) Quad Flat Pack, 3x3mm Body, 0.5mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/ACS711-Datasheet.ashx) +Allegro QFN 0.5 +0 +14 +10 +Sensor_Current +Allegro_QSOP-24_3.9x8.7mm_P0.635mm +Allegro Microsystems 24-Lead Plastic Shrink Small Outline Narrow Body Body [QSOP] (http://www.allegromicro.com/~/media/Files/Datasheets/ACS726-Datasheet.ashx?la=en) +Allegro QSOP 0.635 +0 +24 +24 +Sensor_Current +Allegro_SIP-3 +Allegro Microsystems SIP-3, 1.27mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/A1369-Datasheet.ashx) +Allegro SIP-3 +0 +3 +3 +Sensor_Current +Allegro_SIP-4 +Allegro Microsystems SIP-4, 1.27mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/A1363-Datasheet.ashx) +Allegro SIP-4 +0 +4 +4 +Sensor_Current +Diodes_SIP-3_4.1x1.5mm_P1.27mm +Diodes SIP-3 Bulk Pack, 1.27mm Pitch (https://www.diodes.com/assets/Package-Files/SIP-3-Bulk-Pack.pdf) +Diodes SIP-3 Bulk Pack +0 +3 +3 +Sensor_Current +Diodes_SIP-3_4.1x1.5mm_P2.65mm +Diodes SIP-3 Ammo Pack, 2.65mm Pitch (https://www.diodes.com/assets/Package-Files/SIP-3-Ammo-Pack.pdf) +Diodes SIP-3 Ammo Pack +0 +3 +3 +Sensor_Current +Honeywell_CSLW +https://sensing.honeywell.com/honeywell-sensing-cslw-series-product-sheet-005861-1-en.pdf +Miniature Wired Open-Loop Current Sensor +0 +5 +5 +Sensor_Current +LEM_CKSR +LEM CKSR 6/15/25/50/75-NP Current Transducer, https://www.lem.com/sites/default/files/products_datasheets/cksr_75-np.pdf +current transducer LEM +0 +14 +14 +Sensor_Current +LEM_HO8-NP +LEM HO 8/15/25-NP Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-np-0000_series.pdf) +current transducer +0 +13 +13 +Sensor_Current +LEM_HO8-NSM +LEM HO 8/15/25-NSM Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-nsm-0000_series.pdf) +current transducer +0 +13 +13 +Sensor_Current +LEM_HO40-NP +LEM HO 40/60/120/150-NP Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-np_0100__1100_series.pdf) +current transducer +0 +13 +13 +Sensor_Current +LEM_HTFS +LEM HTFS x00-P current transducer (https://www.lem.com/sites/default/files/products_datasheets/htfs_200_800-p.pdf) +HTFS current transducer +0 +4 +4 +Sensor_Current +LEM_HX02-P +LEM HX02-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX03-P-SP2 +LEM HX03-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX04-P +LEM HX04-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX05-NP +LEM HX05-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf) +hall current +0 +8 +8 +Sensor_Current +LEM_HX05-P-SP2 +LEM HX05-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX06-P +LEM HX06-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX10-NP +LEM HX10-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf) +hall current +0 +8 +8 +Sensor_Current +LEM_HX10-P-SP2 +LEM HX10-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX15-NP +LEM HX15-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf) +hall current +0 +8 +8 +Sensor_Current +LEM_HX15-P-SP2 +LEM HX15-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX20-P-SP2 +LEM HX20-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX25-P-SP2 +LEM HX25-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX50-P-SP2 +LEM HX50-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_LA25-P +LEM Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/la_25-p.pdf) +current transducer +0 +3 +3 +Sensor_Current +LEM_LTSR-NP +LEM current transducer LEM_LTSR-NP 5V supply voltage series https://www.lem.com/sites/default/files/products_datasheets/ltsr_6-np.pdf +Current transducer +0 +10 +10 +Sensor_Distance +ST_VL53L1x +VL53L1x distance sensor +VL53L1CXV0FY1 VL53L1x +0 +13 +12 +Sensor_Humidity +Sensirion_DFN-4-1EP_2x2mm_P1mm_EP0.7x1.6mm +DFN, 4 Pin (https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/0_Datasheets/Humidity/Sensirion_Humidity_Sensors_SHTC3_Datasheet.pdf) +Sensirion DFN NoLead +0 +10 +5 +Sensor_Humidity +Sensirion_DFN-8-1EP_2.5x2.5mm_P0.5mm_EP1.1x1.7mm +Sensirion DFN-8 SHT3x-DIS (https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/2_Humidity_Sensors/Datasheets/Sensirion_Humidity_Sensors_SHT3x_Datasheet_digital.pdf) +sensirion dfn nolead +0 +10 +9 +Sensor_Motion +InvenSense_QFN-24_3x3mm_P0.4mm +24-Lead Plastic QFN (3mm x 3mm); Pitch 0.4mm; EP 1.7x1.54mm; for InvenSense motion sensors; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU9250REV1.0.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.4 +0 +24 +24 +Sensor_Motion +InvenSense_QFN-24_3x3mm_P0.4mm_NoMask +24-Lead Plastic QFN (3mm x 3mm); Pitch 0.4mm; EP 1.7x1.54mm; for InvenSense motion sensors; Mask removed below exposed pad; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU9250REV1.0.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.4 +0 +25 +24 +Sensor_Motion +InvenSense_QFN-24_4x4mm_P0.5mm +24-Lead Plastic QFN (4mm x 4mm); Pitch 0.5mm; EP 2.7x2.6mm; for InvenSense motion sensors; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.5 +0 +24 +24 +Sensor_Motion +InvenSense_QFN-24_4x4mm_P0.5mm_NoMask +24-Lead Plastic QFN (4mm x 4mm); Pitch 0.5mm; EP 2.7x2.6mm; for InvenSense motion sensors; Mask removed below exposed pad; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.5 +0 +25 +24 +Sensor_Pressure +Freescale_98ARH99066A +https://www.nxp.com/docs/en/data-sheet/MPXH6250A.pdf +sensor pressure ssop 98ARH99066A +0 +8 +8 +Sensor_Pressure +Freescale_98ARH99089A +https://www.nxp.com/docs/en/data-sheet/MPXH6250A.pdf +sensor pressure ssop 98ARH99089A +0 +8 +8 +Sensor_Pressure +Honeywell_40PCxxxG1A +https://www.honeywellscportal.com/index.php?ci_id=138832 +pressure sensor automotive honeywell +0 +3 +3 +Sensor_Voltage +LEM_LV25-P +LEM LV25-P Voltage transducer, https://www.lem.com/sites/default/files/products_datasheets/lv_25-p.pdf +LEM Hall Effect Voltage transducer +0 +5 +5 +Socket +3M_Textool_240-1288-00-0602J_2x20_P2.54mm +3M 40-pin zero insertion force socket, though-hole, row spacing 25.4 mm (1000 mils) +THT DIP DIL ZIF 25.4mm 1000mil Socket +0 +40 +40 +Socket +DIP_Socket-14_W4.3_W5.08_W7.62_W10.16_W10.9_3M_214-3339-00-0602J +3M 14-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +14 +14 +Socket +DIP_Socket-16_W4.3_W5.08_W7.62_W10.16_W10.9_3M_216-3340-00-0602J +3M 16-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +16 +16 +Socket +DIP_Socket-18_W4.3_W5.08_W7.62_W10.16_W10.9_3M_218-3341-00-0602J +3M 18-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +18 +18 +Socket +DIP_Socket-20_W4.3_W5.08_W7.62_W10.16_W10.9_3M_220-3342-00-0602J +3M 20-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +20 +20 +Socket +DIP_Socket-22_W6.9_W7.62_W10.16_W12.7_W13.5_3M_222-3343-00-0602J +3M 22-pin zero insertion force socket, through-hole, row spacing 10.16 mm (400 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 10.16mm 400mil Socket +0 +22 +22 +Socket +DIP_Socket-24_W4.3_W5.08_W7.62_W10.16_W10.9_3M_224-5248-00-0602J +3M 24-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +24 +24 +Socket +DIP_Socket-24_W11.9_W12.7_W15.24_W17.78_W18.5_3M_224-1275-00-0602J +3M 24-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +24 +24 +Socket +DIP_Socket-28_W6.9_W7.62_W10.16_W12.7_W13.5_3M_228-4817-00-0602J +3M 28-pin zero insertion force socket, through-hole, row spacing 10.16 mm (400 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 10.16mm 400mil Socket +0 +28 +28 +Socket +DIP_Socket-28_W11.9_W12.7_W15.24_W17.78_W18.5_3M_228-1277-00-0602J +3M 28-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +28 +28 +Socket +DIP_Socket-32_W11.9_W12.7_W15.24_W17.78_W18.5_3M_232-1285-00-0602J +3M 32-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +32 +32 +Socket +DIP_Socket-40_W11.9_W12.7_W15.24_W17.78_W18.5_3M_240-1280-00-0602J +3M 40-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +40 +40 +Socket +DIP_Socket-40_W22.1_W22.86_W25.4_W27.94_W28.7_3M_240-3639-00-0602J +3M 40-pin zero insertion force socket, through-hole, row spacing 25.4 mm (1000 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 25.4mm 1000mil Socket +0 +40 +40 +Socket +DIP_Socket-42_W11.9_W12.7_W15.24_W17.78_W18.5_3M_242-1281-00-0602J +3M 42-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +42 +42 +Socket +Wells_648-0482211SA01 +https://www.farnell.com/cad/316865.pdf?_ga=2.37208032.177107060.1530611323-249019997.1498114824 +48pin TSOP Socket +0 +48 +48 +SofleChocTop +ChocCutout + + +0 +0 +0 +SofleChocTop +SW_Hole + + +0 +0 +0 +Symbol +CE-Logo_8.5x6mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_11.2x8mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_16.8x12mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_28x20mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_42x30mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_56.1x40mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +ESD-Logo_6.6x6mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_8.9x8mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_13.2x12mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_22x20mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_33x30mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_44.1x40mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +FCC-Logo_7.3x6mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_9.6x8mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_14.6x12mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_24.2x20mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_36.3x30mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_48.3x40mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +KiCad-Logo2_5mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_5mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_6mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_6mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_8mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_8mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_12mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_12mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_20mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_20mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_30mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_30mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_40mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_40mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_5mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_5mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_6mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_6mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_8mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_8mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_12mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_12mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_20mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_20mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_30mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_30mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_40mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_40mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +OSHW-Logo2_7.3x6mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_7.3x6mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_9.8x8mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_9.8x8mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_14.6x12mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_14.6x12mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_24.3x20mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_24.3x20mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_36.5x30mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_36.5x30mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_48.7x40mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_48.7x40mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo_5.7x6mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_5.7x6mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_7.5x8mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_7.5x8mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_11.4x12mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_11.4x12mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_19x20mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_19x20mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_28.5x30mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_28.5x30mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_38.1x40mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_38.1x40mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Symbol_6.7x6mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_6.7x6mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_8.9x8mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_8.9x8mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_13.4x12mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_13.4x12mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_22.3x20mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_22.3x20mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_33.5x30mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_33.5x30mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_44.5x40mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_44.5x40mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +Polarity_Center_Negative_6mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_8mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_12mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_20mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_30mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_40mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Positive_6mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_8mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_12mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_20mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_30mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_40mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +RoHS-Logo_6mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_8mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_12mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_20mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_30mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_40mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +Symbol_Attention_CopperTop_Big +Symbol, Attention, Copper Top, Big, +Symbol, Attention, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_Attention_CopperTop_Small +Symbol, Attention, Copper Top, Small, +Symbol, Attention, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_Barrel_Polarity +Barrel connector polarity indicator +barrel polarity +0 +0 +0 +Symbol +Symbol_CC-Attribution_CopperTop_Big +Symbol, CC-Attribution, Copper Top, Big, +Symbol, CC-Attribution, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-Attribution_CopperTop_Small +Symbol, CC-Share Alike, Copper Top, Small, +Symbol, CC-Share Alike, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CC-Noncommercial_CopperTop_Big +Symbol, CC-Noncommercial, Copper Top, Big, +Symbol, CC-Noncommercial, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-Noncommercial_CopperTop_Small +Symbol, CC-Noncommercial Alike, Copper Top, Small, +Symbol, CC-Noncommercial Alike, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CC-PublicDomain_CopperTop_Big +Symbol, CC-PublicDomain, Copper Top, Big, +Symbol, CC-PublicDomain, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-PublicDomain_CopperTop_Small +Symbol, CC-Public Domain, Copper Top, Small, +Symbol, CC-Public Domain, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CC-PublicDomain_SilkScreenTop_Big +Symbol, CC-PublicDomain, SilkScreen Top, Big, +Symbol, CC-PublicDomain, SilkScreen Top, Big, +0 +0 +0 +Symbol +Symbol_CC-ShareAlike_CopperTop_Big +Symbol, CC-Share Alike, Copper Top, Big, +Symbol, CC-Share Alike, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-ShareAlike_CopperTop_Small +Symbol, CC-Share Alike, Copper Top, Small, +Symbol, CC-Share Alike, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommonsPublicDomain_CopperTop_Small +Symbol, Creative Commons Public Domain, CopperTop, Small, +Symbol, Creative Commons Public Domain, CopperTop, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommonsPublicDomain_SilkScreenTop_Small +Symbol, Creative Commons Public Domain, SilkScreenTop, Small, +Symbol, Creative Commons Public Domain, SilkScreen Top, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommons_CopperTop_Type1_Big +Symbol, Creative Commons, CopperTop, Type 1, Big, +Symbol, Creative Commons, CopperTop, Type 1, Big, +0 +0 +0 +Symbol +Symbol_CreativeCommons_CopperTop_Type2_Big +Symbol, Creative Commons, CopperTop, Type 2, Big, +Symbol, Creative Commons, CopperTop, Type 2, Big, +0 +0 +0 +Symbol +Symbol_CreativeCommons_CopperTop_Type2_Small +Symbol, Creative Commons, CopperTop, Type 2, Small, +Symbol, Creative Commons, CopperTop, Type 2, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommons_SilkScreenTop_Type2_Big +Symbol, Creative Commons, SilkScreen Top, Type 2, Big, +Symbol, Creative Commons, SilkScreen Top, Type 2, Big, +0 +0 +0 +Symbol +Symbol_Danger_CopperTop_Big +Symbol, Danger, CopperTop, Big, +Symbol, Danger, CopperTop, Big, +0 +0 +0 +Symbol +Symbol_Danger_CopperTop_Small +Symbol, Danger, Copper Top, Small, +Symbol, Danger, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_ESD-Logo-Text_CopperTop + + +0 +0 +0 +Symbol +Symbol_ESD-Logo_CopperTop +ESD-Logo, similar JEDEC-14, without text, ohne Text, Copper Top, +ESD-Logo, similar JEDEC-14, without text, ohne Text, Copper Top, +0 +0 +0 +Symbol +Symbol_GNU-GPL_CopperTop_Big +Symbol, GNU-GPL, Copper Top, Big, +Symbol, GNU-GPL, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_GNU-GPL_CopperTop_Small +Symbol, GNU-GPL, Copper Top, Small, +Symbol, GNU-GPL, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_GNU-Logo_CopperTop +GNU-Logo, GNU-Head, GNU-Kopf, Copper Top, +GNU-Logo, GNU-Head, GNU-Kopf, Copper Top, +0 +0 +0 +Symbol +Symbol_GNU-Logo_SilkscreenTop +GNU-Logo, GNU-Head, GNU-Kopf, Silkscreen, +GNU-Logo, GNU-Head, GNU-Kopf, Silkscreen, +0 +0 +0 +Symbol +Symbol_HighVoltage_Type1_CopperTop_Big +Symbol, HighVoltage, Type1, Copper Top, Big, +Symbol, HighVoltage, Type1, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_HighVoltage_Type2_CopperTop_Big +Symbol, HighVoltage, Type2, Copper Top, Big, +Symbol, HighVoltage, Type2, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_HighVoltage_Type2_CopperTop_VerySmall +Symbol, High Voltage, Type 2, Copper Top, Very Small, +Symbol, High Voltage, Type 2, Copper Top, Very Small, +0 +0 +0 +Symbol +Symbol_Highvoltage_Type1_CopperTop_Small +Symbol, Highvoltage, Type 1, Copper Top, Small, +Symbol, Highvoltage, Type 1, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_Highvoltage_Type2_CopperTop_Small +Symbol, Highvoltage, Type 2, Copper Top, Small, +Symbol, Highvoltage, Type 2, Copper Top, Small, +0 +0 +0 +Symbol +WEEE-Logo_4.2x6mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_5.6x8mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_8.4x12mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_14x20mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_21x30mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_28.1x40mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +TerminalBlock +TerminalBlock_Altech_AK300-2_P5.00mm +Altech AK300 terminal block, pitch 5.0mm, 45 degree angled, see http://www.mouser.com/ds/2/16/PCBMETRC-24178.pdf +Altech AK300 terminal block pitch 5.0mm +0 +2 +2 +TerminalBlock +TerminalBlock_Altech_AK300-3_P5.00mm +Altech AK300 terminal block, pitch 5.0mm, 45 degree angled, see http://www.mouser.com/ds/2/16/PCBMETRC-24178.pdf +Altech AK300 terminal block pitch 5.0mm +0 +3 +3 +TerminalBlock +TerminalBlock_Altech_AK300-4_P5.00mm +Altech AK300 terminal block, pitch 5.0mm, 45 degree angled, see http://www.mouser.com/ds/2/16/PCBMETRC-24178.pdf +Altech AK300 terminal block pitch 5.0mm +0 +4 +4 +TerminalBlock +TerminalBlock_Wuerth_691311400102_P7.62mm +https://katalog.we-online.de/em/datasheet/6913114001xx.pdf +Wuerth WR-TBL Series 3114 terminal block pitch 7.62mm +0 +2 +2 +TerminalBlock +TerminalBlock_bornier-2_P5.08mm +simple 2-pin terminal block, pitch 5.08mm, revamped version of bornier2 +terminal block bornier2 +0 +2 +2 +TerminalBlock +TerminalBlock_bornier-3_P5.08mm +simple 3-pin terminal block, pitch 5.08mm, revamped version of bornier3 +terminal block bornier3 +0 +3 +3 +TerminalBlock +TerminalBlock_bornier-4_P5.08mm +simple 4-pin terminal block, pitch 5.08mm, revamped version of bornier4 +terminal block bornier4 +0 +4 +4 +TerminalBlock +TerminalBlock_bornier-5_P5.08mm +simple 5-pin terminal block, pitch 5.08mm, revamped version of bornier5 +terminal block bornier5 +0 +5 +5 +TerminalBlock +TerminalBlock_bornier-6_P5.08mm +simple 6pin terminal block, pitch 5.08mm, revamped version of bornier6 +terminal block bornier6 +0 +6 +6 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x02_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 19963, 2 pins, pitch 3.5mm, size 7.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/19963.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 19963 pitch 3.5mm size 7.7x7mm^2 drill 1.2mm pad 2.4mm +0 +2 +2 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x02_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10693, vertical (cable from top), 2 pins, pitch 3.5mm, size 8x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10693.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10693 vertical pitch 3.5mm size 8x8.3mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x03_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 20193, 3 pins, pitch 3.5mm, size 11.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/20193.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 20193 pitch 3.5mm size 11.2x7mm^2 drill 1.2mm pad 2.4mm +0 +3 +3 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x03_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10694, vertical (cable from top), 3 pins, pitch 3.5mm, size 11.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10694.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10694 vertical pitch 3.5mm size 11.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x04_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 20001, 4 pins, pitch 3.5mm, size 14.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/20001.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 20001 pitch 3.5mm size 14.7x7mm^2 drill 1.2mm pad 2.4mm +0 +4 +4 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x04_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10695, vertical (cable from top), 4 pins, pitch 3.5mm, size 15x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10695.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10695 vertical pitch 3.5mm size 15x8.3mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x05_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 20223, 5 pins, pitch 3.5mm, size 18.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/20223.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 20223 pitch 3.5mm size 18.2x7mm^2 drill 1.2mm pad 2.4mm +0 +5 +5 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x05_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10696, vertical (cable from top), 5 pins, pitch 3.5mm, size 18.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10696.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10696 vertical pitch 3.5mm size 18.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x06_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 19964, 6 pins, pitch 3.5mm, size 21.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/19964.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 19964 pitch 3.5mm size 21.7x7mm^2 drill 1.2mm pad 2.4mm +0 +6 +6 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x06_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10697, vertical (cable from top), 6 pins, pitch 3.5mm, size 22x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10697.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10697 vertical pitch 3.5mm size 22x8.3mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x07_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10684, 7 pins, pitch 3.5mm, size 25.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10684.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10684 pitch 3.5mm size 25.2x7mm^2 drill 1.2mm pad 2.4mm +0 +7 +7 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x07_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10698, vertical (cable from top), 7 pins, pitch 3.5mm, size 25.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10698.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10698 vertical pitch 3.5mm size 25.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x08_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 19965, 8 pins, pitch 3.5mm, size 28.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/19965.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 19965 pitch 3.5mm size 28.7x7mm^2 drill 1.2mm pad 2.4mm +0 +8 +8 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x08_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10699, vertical (cable from top), 8 pins, pitch 3.5mm, size 29x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10699.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10699 vertical pitch 3.5mm size 29x8.3mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x09_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10686, 9 pins, pitch 3.5mm, size 32.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10686.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10686 pitch 3.5mm size 32.2x7mm^2 drill 1.2mm pad 2.4mm +0 +9 +9 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x09_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10700, vertical (cable from top), 9 pins, pitch 3.5mm, size 32.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10700.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10700 vertical pitch 3.5mm size 32.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x10_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10687, 10 pins, pitch 3.5mm, size 35.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10687.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10687 pitch 3.5mm size 35.7x7mm^2 drill 1.2mm pad 2.4mm +0 +10 +10 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x10_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10701, vertical (cable from top), 10 pins, pitch 3.5mm, size 36x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10701.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10701 vertical pitch 3.5mm size 36x8.3mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x11_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10688, 11 pins, pitch 3.5mm, size 39.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10688.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10688 pitch 3.5mm size 39.2x7mm^2 drill 1.2mm pad 2.4mm +0 +11 +11 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x11_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10702, vertical (cable from top), 11 pins, pitch 3.5mm, size 39.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10702.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10702 vertical pitch 3.5mm size 39.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x12_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10689, 12 pins, pitch 3.5mm, size 42.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10689.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10689 pitch 3.5mm size 42.7x7mm^2 drill 1.2mm pad 2.4mm +0 +12 +12 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x12_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10703, vertical (cable from top), 12 pins, pitch 3.5mm, size 43x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10703.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10703 vertical pitch 3.5mm size 43x8.3mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x13_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10690, 13 pins, pitch 3.5mm, size 46.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10690.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10690 pitch 3.5mm size 46.2x7mm^2 drill 1.2mm pad 2.4mm +0 +13 +13 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x13_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10704, vertical (cable from top), 13 pins, pitch 3.5mm, size 46.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10704.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10704 vertical pitch 3.5mm size 46.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x14_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10691, 14 pins, pitch 3.5mm, size 49.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10691.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10691 pitch 3.5mm size 49.7x7mm^2 drill 1.2mm pad 2.4mm +0 +14 +14 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x14_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10705, vertical (cable from top), 14 pins, pitch 3.5mm, size 50x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10705.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10705 vertical pitch 3.5mm size 50x8.3mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x15_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10692, 15 pins, pitch 3.5mm, size 53.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10692.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10692 pitch 3.5mm size 53.2x7mm^2 drill 1.2mm pad 2.4mm +0 +15 +15 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x15_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10706, vertical (cable from top), 15 pins, pitch 3.5mm, size 53.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10706.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10706 vertical pitch 3.5mm size 53.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Altech +Altech_AK300_1x02_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +2 +2 +TerminalBlock_Altech +Altech_AK300_1x03_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +3 +3 +TerminalBlock_Altech +Altech_AK300_1x04_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +4 +4 +TerminalBlock_Altech +Altech_AK300_1x05_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +5 +5 +TerminalBlock_Altech +Altech_AK300_1x06_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +6 +6 +TerminalBlock_Altech +Altech_AK300_1x07_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +7 +7 +TerminalBlock_Altech +Altech_AK300_1x08_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +8 +8 +TerminalBlock_Altech +Altech_AK300_1x09_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +9 +9 +TerminalBlock_Altech +Altech_AK300_1x10_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +10 +10 +TerminalBlock_Altech +Altech_AK300_1x11_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +11 +11 +TerminalBlock_Altech +Altech_AK300_1x12_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +12 +12 +TerminalBlock_Altech +Altech_AK300_1x13_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +13 +13 +TerminalBlock_Altech +Altech_AK300_1x14_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +14 +14 +TerminalBlock_Altech +Altech_AK300_1x15_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +15 +15 +TerminalBlock_Altech +Altech_AK300_1x16_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +16 +16 +TerminalBlock_Altech +Altech_AK300_1x17_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +17 +17 +TerminalBlock_Altech +Altech_AK300_1x18_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +18 +18 +TerminalBlock_Altech +Altech_AK300_1x19_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +19 +19 +TerminalBlock_Altech +Altech_AK300_1x20_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +20 +20 +TerminalBlock_Altech +Altech_AK300_1x21_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +21 +21 +TerminalBlock_Altech +Altech_AK300_1x22_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +22 +22 +TerminalBlock_Altech +Altech_AK300_1x23_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +23 +23 +TerminalBlock_Altech +Altech_AK300_1x24_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +24 +24 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-02_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +2 +2 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-03_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +3 +3 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-04_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +4 +4 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-05_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +5 +5 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-06_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +6 +6 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-07_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +7 +7 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-08_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +8 +8 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-09_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +9 +9 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-10_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +10 +10 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-11_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +11 +11 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-12_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +12 +12 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-13_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +13 +13 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-14_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +14 +14 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-15_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +15 +15 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-16_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +16 +16 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-17_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +17 +17 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-18_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +18 +18 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-19_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +19 +19 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-20_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +20 +20 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-21_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +21 +21 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-22_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +22 +22 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-23_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +23 +23 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-24_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +24 +24 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-25_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +25 +25 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-26_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +26 +26 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-27_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +27 +27 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-28_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +28 +28 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-29_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +29 +29 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-30_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +30 +30 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360271_1x01_Horizontal_ScrewM3.0_Boxed +single screw terminal block Metz Connect 360271, block size 9x7.3mm^2, drill diamater 1.5mm, 1 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 134, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360271 size 9x7.3mm^2 drill 1.5mm pad 3mm +0 +1 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360272_1x01_Horizontal_ScrewM2.6 +single screw terminal block Metz Connect 360272, block size 4x4mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 131, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360272 size 4x4mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360273_1x01_Horizontal_ScrewM2.6_WireProtection +single screw terminal block Metz Connect 360273, block size 5x4mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 131, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360273 size 5x4mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360291_1x01_Horizontal_ScrewM3.0_Boxed +single screw terminal block Metz Connect 360291, block size 9x7.3mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 133, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360291 size 9x7.3mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360322_1x01_Horizontal_ScrewM3.0_WireProtection +single screw terminal block Metz Connect 360322, block size 6x4mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 133, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360322 size 6x4mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360381_1x01_Horizontal_ScrewM3.0 +single screw terminal block Metz Connect 360381, block size 5x5mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 133, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360381 size 5x5mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360410_1x01_Horizontal_ScrewM3.0 +single screw terminal block Metz Connect 360410, block size 5x5mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 132, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360410 size 5x5mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360425_1x01_Horizontal_ScrewM4.0_Boxed +single screw terminal block Metz Connect 360425, block size 9x9mm^2, drill diamater 1.6mm, 4 pads, pad diameter 3.2mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 134, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360425 size 9x9mm^2 drill 1.6mm pad 3.2mm +0 +4 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05502HBWC_1x02_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05502HBWC, 2 pins, pitch 5mm, size 10x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05502HBWC pitch 5mm size 10x10.5mm^2 drill 1.4mm pad 2.8mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05503HBWC_1x03_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05503HBWC, 3 pins, pitch 5mm, size 15x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05503HBWC pitch 5mm size 15x10.5mm^2 drill 1.4mm pad 2.8mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05504HBWC_1x04_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05504HBWC, 4 pins, pitch 5mm, size 20x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05504HBWC pitch 5mm size 20x10.5mm^2 drill 1.4mm pad 2.8mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05505HBWC_1x05_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05505HBWC, 5 pins, pitch 5mm, size 25x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05505HBWC pitch 5mm size 25x10.5mm^2 drill 1.4mm pad 2.8mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05506HBWC_1x06_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05506HBWC, 6 pins, pitch 5mm, size 30x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05506HBWC pitch 5mm size 30x10.5mm^2 drill 1.4mm pad 2.8mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type055_RT01502HDWU_1x02_P5.00mm_Horizontal +terminal block Metz Connect Type055_RT01502HDWU, 2 pins, pitch 5mm, size 10x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310551_RT015xxHDWU_OFF-022723S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type055_RT01502HDWU pitch 5mm size 10x8mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type055_RT01503HDWU_1x03_P5.00mm_Horizontal +terminal block Metz Connect Type055_RT01503HDWU, 3 pins, pitch 5mm, size 15x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310551_RT015xxHDWU_OFF-022723S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type055_RT01503HDWU pitch 5mm size 15x8mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type055_RT01504HDWU_1x04_P5.00mm_Horizontal +terminal block Metz Connect Type055_RT01504HDWU, 4 pins, pitch 5mm, size 20x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310551_RT015xxHDWU_OFF-022723S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type055_RT01504HDWU pitch 5mm size 20x8mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06302HBWC_1x02_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06302HBWC, 2 pins, pitch 3.5mm, size 7x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06302HBWC pitch 3.5mm size 7x6.5mm^2 drill 1.2mm pad 2.3mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06303HBWC_1x03_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06303HBWC, 3 pins, pitch 3.5mm, size 10.5x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06303HBWC pitch 3.5mm size 10.5x6.5mm^2 drill 1.2mm pad 2.3mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06304HBWC_1x04_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06304HBWC, 4 pins, pitch 3.5mm, size 14x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06304HBWC pitch 3.5mm size 14x6.5mm^2 drill 1.2mm pad 2.3mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06305HBWC_1x05_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06305HBWC, 5 pins, pitch 3.5mm, size 17.5x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06305HBWC pitch 3.5mm size 17.5x6.5mm^2 drill 1.2mm pad 2.3mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06306HBWC_1x06_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06306HBWC, 6 pins, pitch 3.5mm, size 21x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06306HBWC pitch 3.5mm size 21x6.5mm^2 drill 1.2mm pad 2.3mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01902HDWC_1x02_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01902HDWC, 2 pins, pitch 10mm, size 15.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01902HDWC pitch 10mm size 15.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01903HDWC_1x03_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01903HDWC, 3 pins, pitch 10mm, size 25.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01903HDWC pitch 10mm size 25.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01904HDWC_1x04_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01904HDWC, 4 pins, pitch 10mm, size 35.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01904HDWC pitch 10mm size 35.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01905HDWC_1x05_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01905HDWC, 5 pins, pitch 10mm, size 45.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01905HDWC pitch 10mm size 45.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type073_RT02602HBLU_1x02_P5.08mm_Horizontal +terminal block Metz Connect Type073_RT02602HBLU, 2 pins, pitch 5.08mm, size 10.2x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310731_RT026xxHBLU_OFF-022792U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type073_RT02602HBLU pitch 5.08mm size 10.2x11mm^2 drill 1.4mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type073_RT02603HBLU_1x03_P5.08mm_Horizontal +terminal block Metz Connect Type073_RT02603HBLU, 3 pins, pitch 5.08mm, size 15.2x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310731_RT026xxHBLU_OFF-022792U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type073_RT02603HBLU pitch 5.08mm size 15.2x11mm^2 drill 1.4mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03402HBLC_1x02_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03402HBLC, 2 pins, pitch 3.81mm, size 7.51x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03402HBLC pitch 3.81mm size 7.51x7.3mm^2 drill 0.7mm pad 1.4mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03403HBLC_1x03_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03403HBLC, 3 pins, pitch 3.81mm, size 11.3x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03403HBLC pitch 3.81mm size 11.3x7.3mm^2 drill 0.7mm pad 1.4mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03404HBLC_1x04_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03404HBLC, 4 pins, pitch 3.81mm, size 15.1x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03404HBLC pitch 3.81mm size 15.1x7.3mm^2 drill 0.7mm pad 1.4mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03405HBLC_1x05_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03405HBLC, 5 pins, pitch 3.81mm, size 18.9x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03405HBLC pitch 3.81mm size 18.9x7.3mm^2 drill 0.7mm pad 1.4mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03406HBLC_1x06_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03406HBLC, 6 pins, pitch 3.81mm, size 22.8x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03406HBLC pitch 3.81mm size 22.8x7.3mm^2 drill 0.7mm pad 1.4mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03502HBLU_1x02_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03502HBLU, 2 pins, pitch 5mm, size 10x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03502HBLU pitch 5mm size 10x8.3mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03503HBLU_1x03_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03503HBLU, 3 pins, pitch 5mm, size 15x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03503HBLU pitch 5mm size 15x8.3mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03504HBLU_1x04_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03504HBLU, 4 pins, pitch 5mm, size 20x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03504HBLU pitch 5mm size 20x8.3mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03505HBLU_1x05_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03505HBLU, 5 pins, pitch 5mm, size 25x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03505HBLU pitch 5mm size 25x8.3mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03506HBLU_1x06_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03506HBLU, 6 pins, pitch 5mm, size 30x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03506HBLU pitch 5mm size 30x8.3mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01602HBWC_1x02_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01602HBWC, 2 pins, pitch 5.08mm, size 10.2x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01602HBWC pitch 5.08mm size 10.2x8mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01603HBWC_1x03_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01603HBWC, 3 pins, pitch 5.08mm, size 15.2x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01603HBWC pitch 5.08mm size 15.2x8mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01604HBWC_1x04_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01604HBWC, 4 pins, pitch 5.08mm, size 20.3x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01604HBWC pitch 5.08mm size 20.3x8mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01605HBWC_1x05_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01605HBWC, 5 pins, pitch 5.08mm, size 25.4x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01605HBWC pitch 5.08mm size 25.4x8mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01606HBWC_1x06_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01606HBWC, 6 pins, pitch 5.08mm, size 30.5x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01606HBWC pitch 5.08mm size 30.5x8mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13702HBWC_1x02_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13702HBWC, 2 pins, pitch 7.5mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13702HBWC pitch 7.5mm size 15x9mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13703HBWC_1x03_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13703HBWC, 3 pins, pitch 7.5mm, size 22.5x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13703HBWC pitch 7.5mm size 22.5x9mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13704HBWC_1x04_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13704HBWC, 4 pins, pitch 7.5mm, size 30x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13704HBWC pitch 7.5mm size 30x9mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13705HBWC_1x05_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13705HBWC, 5 pins, pitch 7.5mm, size 37.5x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13705HBWC pitch 7.5mm size 37.5x9mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13706HBWC_1x06_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13706HBWC, 6 pins, pitch 7.5mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13706HBWC pitch 7.5mm size 45x9mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02702HBLC_1x02_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02702HBLC, 2 pins, pitch 7.5mm, size 15x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02702HBLC pitch 7.5mm size 15x11mm^2 drill 1.4mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02703HBLC_1x03_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02703HBLC, 3 pins, pitch 7.5mm, size 22.5x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02703HBLC pitch 7.5mm size 22.5x11mm^2 drill 1.4mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02704HBLC_1x04_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02704HBLC, 4 pins, pitch 7.5mm, size 30x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02704HBLC pitch 7.5mm size 30x11mm^2 drill 1.4mm pad 2.6mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02705HBLC_1x05_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02705HBLC, 5 pins, pitch 7.5mm, size 37.5x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02705HBLC pitch 7.5mm size 37.5x11mm^2 drill 1.4mm pad 2.6mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02706HBLC_1x06_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02706HBLC, 6 pins, pitch 7.5mm, size 45x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02706HBLC pitch 7.5mm size 45x11mm^2 drill 1.4mm pad 2.6mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04502UBLC_1x02_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04502UBLC, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 10x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04502UBLC 45Degree pitch 5mm size 10x12.5mm^2 drill 1.4mm pad 2.7mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04503UBLC_1x03_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04503UBLC, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 15x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04503UBLC 45Degree pitch 5mm size 15x12.5mm^2 drill 1.4mm pad 2.7mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04504UBLC_1x04_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04504UBLC, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 20x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04504UBLC 45Degree pitch 5mm size 20x12.5mm^2 drill 1.4mm pad 2.7mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04505UBLC_1x05_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04505UBLC, 45Degree (cable under 45degree), 5 pins, pitch 5mm, size 25x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04505UBLC 45Degree pitch 5mm size 25x12.5mm^2 drill 1.4mm pad 2.7mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04506UBLC_1x06_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04506UBLC, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 30x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04506UBLC 45Degree pitch 5mm size 30x12.5mm^2 drill 1.4mm pad 2.7mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type701_RT11L02HGLU_1x02_P6.35mm_Horizontal +terminal block Metz Connect Type701_RT11L02HGLU, 2 pins, pitch 6.35mm, size 12.7x12.5mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317011_RT11LxxHGLU_OFF-022798U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type701_RT11L02HGLU pitch 6.35mm size 12.7x12.5mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type701_RT11L03HGLU_1x03_P6.35mm_Horizontal +terminal block Metz Connect Type701_RT11L03HGLU, 3 pins, pitch 6.35mm, size 19x12.5mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317011_RT11LxxHGLU_OFF-022798U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type701_RT11L03HGLU pitch 6.35mm size 19x12.5mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type703_RT10N02HGLU_1x02_P9.52mm_Horizontal +terminal block Metz Connect Type703_RT10N02HGLU, 2 pins, pitch 9.52mm, size 19x12.5mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317031_RT10NxxHGLU_OFF-022897S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type703_RT10N02HGLU pitch 9.52mm size 19x12.5mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type703_RT10N03HGLU_1x03_P9.52mm_Horizontal +terminal block Metz Connect Type703_RT10N03HGLU, 3 pins, pitch 9.52mm, size 28.6x12.5mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317031_RT10NxxHGLU_OFF-022897S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type703_RT10N03HGLU pitch 9.52mm size 28.6x12.5mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Philmore +TerminalBlock_Philmore_TB132_1x02_P5.00mm_Horizontal +Terminal Block Philmore , 2 pins, pitch 5mm, size 10x10.2mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.philmore-datak.com/mc/Page%20197.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Philmore +THT Terminal Block Philmore pitch 5mm size 10x10.2mm^2 drill 1.2mm pad 2.4mm +0 +2 +2 +TerminalBlock_Philmore +TerminalBlock_Philmore_TB133_1x03_P5.00mm_Horizontal +Terminal Block Philmore , 3 pins, pitch 5mm, size 15x10.2mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.philmore-datak.com/mc/Page%20197.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Philmore +THT Terminal Block Philmore pitch 5mm size 15x10.2mm^2 drill 1.2mm pad 2.4mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-2-5.08_1x02_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-2-5.08, 2 pins, pitch 5.08mm, size 10.2x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-2-5.08 pitch 5.08mm size 10.2x9.8mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-2_1x02_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-2, 2 pins, pitch 5mm, size 10x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-2 pitch 5mm size 10x9.8mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-3-5.08_1x03_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-3-5.08, 3 pins, pitch 5.08mm, size 15.2x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-3-5.08 pitch 5.08mm size 15.2x9.8mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-3_1x03_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-3, 3 pins, pitch 5mm, size 15x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-3 pitch 5mm size 15x9.8mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-4-5.08_1x04_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-4-5.08, 4 pins, pitch 5.08mm, size 20.3x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-4-5.08 pitch 5.08mm size 20.3x9.8mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-4_1x04_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-4, 4 pins, pitch 5mm, size 20x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-4 pitch 5mm size 20x9.8mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-5-5.08_1x05_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-5-5.08, 5 pins, pitch 5.08mm, size 25.4x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-5-5.08 pitch 5.08mm size 25.4x9.8mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-5_1x05_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-5, 5 pins, pitch 5mm, size 25x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-5 pitch 5mm size 25x9.8mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-6-5.08_1x06_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-6-5.08, 6 pins, pitch 5.08mm, size 30.5x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-6-5.08 pitch 5.08mm size 30.5x9.8mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-6_1x06_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-6, 6 pins, pitch 5mm, size 30x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-6 pitch 5mm size 30x9.8mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-7-5.08_1x07_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-7-5.08, 7 pins, pitch 5.08mm, size 35.6x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-7-5.08 pitch 5.08mm size 35.6x9.8mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-7_1x07_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-7, 7 pins, pitch 5mm, size 35x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-7 pitch 5mm size 35x9.8mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-8-5.08_1x08_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-8-5.08, 8 pins, pitch 5.08mm, size 40.6x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-8-5.08 pitch 5.08mm size 40.6x9.8mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-8_1x08_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-8, 8 pins, pitch 5mm, size 40x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-8 pitch 5mm size 40x9.8mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-9-5.08_1x09_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-9-5.08, 9 pins, pitch 5.08mm, size 45.7x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-9-5.08 pitch 5.08mm size 45.7x9.8mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-9_1x09_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-9, 9 pins, pitch 5mm, size 45x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-9 pitch 5mm size 45x9.8mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-10-5.08_1x10_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-10-5.08, 10 pins, pitch 5.08mm, size 50.8x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-10-5.08 pitch 5.08mm size 50.8x9.8mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-10_1x10_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-10, 10 pins, pitch 5mm, size 50x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-10 pitch 5mm size 50x9.8mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-11-5.08_1x11_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-11-5.08, 11 pins, pitch 5.08mm, size 55.9x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-11-5.08 pitch 5.08mm size 55.9x9.8mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-11_1x11_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-11, 11 pins, pitch 5mm, size 55x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-11 pitch 5mm size 55x9.8mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-12-5.08_1x12_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-12-5.08, 12 pins, pitch 5.08mm, size 61x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-12-5.08 pitch 5.08mm size 61x9.8mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-12_1x12_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-12, 12 pins, pitch 5mm, size 60x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-12 pitch 5mm size 60x9.8mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-13-5.08_1x13_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-13-5.08, 13 pins, pitch 5.08mm, size 66x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-13-5.08 pitch 5.08mm size 66x9.8mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-13_1x13_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-13, 13 pins, pitch 5mm, size 65x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-13 pitch 5mm size 65x9.8mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-14-5.08_1x14_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-14-5.08, 14 pins, pitch 5.08mm, size 71.1x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-14-5.08 pitch 5.08mm size 71.1x9.8mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-14_1x14_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-14, 14 pins, pitch 5mm, size 70x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-14 pitch 5mm size 70x9.8mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-15-5.08_1x15_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-15-5.08, 15 pins, pitch 5.08mm, size 76.2x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-15-5.08 pitch 5.08mm size 76.2x9.8mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-15_1x15_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-15, 15 pins, pitch 5mm, size 75x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-15 pitch 5mm size 75x9.8mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-16-5.08_1x16_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-16-5.08, 16 pins, pitch 5.08mm, size 81.3x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-16-5.08 pitch 5.08mm size 81.3x9.8mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-16_1x16_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-16, 16 pins, pitch 5mm, size 80x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-16 pitch 5mm size 80x9.8mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-2-5.08_1x02_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-2-5.08, 2 pins, pitch 5.08mm, size 10.2x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-2-5.08 pitch 5.08mm size 10.2x11.2mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-3-5.08_1x03_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-3-5.08, 3 pins, pitch 5.08mm, size 15.2x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-3-5.08 pitch 5.08mm size 15.2x11.2mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-4-5.08_1x04_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-4-5.08, 4 pins, pitch 5.08mm, size 20.3x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-4-5.08 pitch 5.08mm size 20.3x11.2mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-5-5.08_1x05_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-5-5.08, 5 pins, pitch 5.08mm, size 25.4x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-5-5.08 pitch 5.08mm size 25.4x11.2mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-6-5.08_1x06_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-6-5.08, 6 pins, pitch 5.08mm, size 30.5x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-6-5.08 pitch 5.08mm size 30.5x11.2mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-7-5.08_1x07_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-7-5.08, 7 pins, pitch 5.08mm, size 35.6x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-7-5.08 pitch 5.08mm size 35.6x11.2mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-8-5.08_1x08_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-8-5.08, 8 pins, pitch 5.08mm, size 40.6x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-8-5.08 pitch 5.08mm size 40.6x11.2mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-9-5.08_1x09_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-9-5.08, 9 pins, pitch 5.08mm, size 45.7x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-9-5.08 pitch 5.08mm size 45.7x11.2mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-10-5.08_1x10_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-10-5.08, 10 pins, pitch 5.08mm, size 50.8x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-10-5.08 pitch 5.08mm size 50.8x11.2mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-11-5.08_1x11_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-11-5.08, 11 pins, pitch 5.08mm, size 55.9x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-11-5.08 pitch 5.08mm size 55.9x11.2mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-12-5.08_1x12_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-12-5.08, 12 pins, pitch 5.08mm, size 61x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-12-5.08 pitch 5.08mm size 61x11.2mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-13-5.08_1x13_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-13-5.08, 13 pins, pitch 5.08mm, size 66x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-13-5.08 pitch 5.08mm size 66x11.2mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-14-5.08_1x14_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-14-5.08, 14 pins, pitch 5.08mm, size 71.1x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-14-5.08 pitch 5.08mm size 71.1x11.2mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-15-5.08_1x15_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-15-5.08, 15 pins, pitch 5.08mm, size 76.2x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-15-5.08 pitch 5.08mm size 76.2x11.2mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-16-5.08_1x16_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-16-5.08, 16 pins, pitch 5.08mm, size 81.3x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-16-5.08 pitch 5.08mm size 81.3x11.2mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-2-2.54_1x02_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-2-2.54, 2 pins, pitch 2.54mm, size 5.54x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725656-920552.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-2-2.54 pitch 2.54mm size 5.54x6.2mm^2 drill 1.1mm pad 2.2mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-3-2.54_1x03_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-3-2.54, 3 pins, pitch 2.54mm, size 8.08x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725656-920552.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-3-2.54 pitch 2.54mm size 8.08x6.2mm^2 drill 1.1mm pad 2.2mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-4-2.54_1x04_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-4-2.54, 4 pins, pitch 2.54mm, size 10.6x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-4-2.54 pitch 2.54mm size 10.6x6.2mm^2 drill 1.1mm pad 2.2mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-5-2.54_1x05_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-5-2.54, 5 pins, pitch 2.54mm, size 13.2x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-5-2.54 pitch 2.54mm size 13.2x6.2mm^2 drill 1.1mm pad 2.2mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-6-2.54_1x06_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-6-2.54, 6 pins, pitch 2.54mm, size 15.7x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-6-2.54 pitch 2.54mm size 15.7x6.2mm^2 drill 1.1mm pad 2.2mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-7-2.54_1x07_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-7-2.54, 7 pins, pitch 2.54mm, size 18.2x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-7-2.54 pitch 2.54mm size 18.2x6.2mm^2 drill 1.1mm pad 2.2mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-8-2.54_1x08_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-8-2.54, 8 pins, pitch 2.54mm, size 20.8x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-8-2.54 pitch 2.54mm size 20.8x6.2mm^2 drill 1.1mm pad 2.2mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-9-2.54_1x09_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-9-2.54, 9 pins, pitch 2.54mm, size 23.3x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-9-2.54 pitch 2.54mm size 23.3x6.2mm^2 drill 1.1mm pad 2.2mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-10-2.54_1x10_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-10-2.54, 10 pins, pitch 2.54mm, size 25.9x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-10-2.54 pitch 2.54mm size 25.9x6.2mm^2 drill 1.1mm pad 2.2mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-11-2.54_1x11_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-11-2.54, 11 pins, pitch 2.54mm, size 28.4x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-11-2.54 pitch 2.54mm size 28.4x6.2mm^2 drill 1.1mm pad 2.2mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-12-2.54_1x12_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-12-2.54, 12 pins, pitch 2.54mm, size 30.9x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-12-2.54 pitch 2.54mm size 30.9x6.2mm^2 drill 1.1mm pad 2.2mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-2-3.5-H_1x02_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-2-3.5-H, 2 pins, pitch 3.5mm, size 7x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-2-3.5-H pitch 3.5mm size 7x7.6mm^2 drill 1.2mm pad 2.4mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-2-5.0-H_1x02_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-2-5.0-H, 2 pins, pitch 5mm, size 10x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-2-5.0-H pitch 5mm size 10x9mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-3-3.5-H_1x03_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-3-3.5-H, 3 pins, pitch 3.5mm, size 10.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-3-3.5-H pitch 3.5mm size 10.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-3-5.0-H_1x03_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-3-5.0-H, 3 pins, pitch 5mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-3-5.0-H pitch 5mm size 15x9mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-4-3.5-H_1x04_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-4-3.5-H, 4 pins, pitch 3.5mm, size 14x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-4-3.5-H pitch 3.5mm size 14x7.6mm^2 drill 1.2mm pad 2.4mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-4-5.0-H_1x04_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-4-5.0-H, 4 pins, pitch 5mm, size 20x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-4-5.0-H pitch 5mm size 20x9mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-5-3.5-H_1x05_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-5-3.5-H, 5 pins, pitch 3.5mm, size 17.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-5-3.5-H pitch 3.5mm size 17.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-5-5.0-H_1x05_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-5-5.0-H, 5 pins, pitch 5mm, size 25x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-5-5.0-H pitch 5mm size 25x9mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-6-3.5-H_1x06_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-6-3.5-H, 6 pins, pitch 3.5mm, size 21x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-6-3.5-H pitch 3.5mm size 21x7.6mm^2 drill 1.2mm pad 2.4mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-6-5.0-H_1x06_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-6-5.0-H, 6 pins, pitch 5mm, size 30x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-6-5.0-H pitch 5mm size 30x9mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-7-3.5-H_1x07_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-7-3.5-H, 7 pins, pitch 3.5mm, size 24.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-7-3.5-H pitch 3.5mm size 24.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-7-5.0-H_1x07_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-7-5.0-H, 7 pins, pitch 5mm, size 35x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-7-5.0-H pitch 5mm size 35x9mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-8-3.5-H_1x08_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-8-3.5-H, 8 pins, pitch 3.5mm, size 28x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-8-3.5-H pitch 3.5mm size 28x7.6mm^2 drill 1.2mm pad 2.4mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-8-5.0-H_1x08_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-8-5.0-H, 8 pins, pitch 5mm, size 40x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-8-5.0-H pitch 5mm size 40x9mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-9-3.5-H_1x09_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-9-3.5-H, 9 pins, pitch 3.5mm, size 31.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-9-3.5-H pitch 3.5mm size 31.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-9-5.0-H_1x09_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-9-5.0-H, 9 pins, pitch 5mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-9-5.0-H pitch 5mm size 45x9mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-10-3.5-H_1x10_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-10-3.5-H, 10 pins, pitch 3.5mm, size 35x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-10-3.5-H pitch 3.5mm size 35x7.6mm^2 drill 1.2mm pad 2.4mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-10-5.0-H_1x10_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-10-5.0-H, 10 pins, pitch 5mm, size 50x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-10-5.0-H pitch 5mm size 50x9mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-11-3.5-H_1x11_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-11-3.5-H, 11 pins, pitch 3.5mm, size 38.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-11-3.5-H pitch 3.5mm size 38.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-11-5.0-H_1x11_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-11-5.0-H, 11 pins, pitch 5mm, size 55x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-11-5.0-H pitch 5mm size 55x9mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-12-3.5-H_1x12_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-12-3.5-H, 12 pins, pitch 3.5mm, size 42x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-12-3.5-H pitch 3.5mm size 42x7.6mm^2 drill 1.2mm pad 2.4mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-12-5.0-H_1x12_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-12-5.0-H, 12 pins, pitch 5mm, size 60x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-12-5.0-H pitch 5mm size 60x9mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-13-3.5-H_1x13_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-13-3.5-H, 13 pins, pitch 3.5mm, size 45.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-13-3.5-H pitch 3.5mm size 45.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-13-5.0-H_1x13_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-13-5.0-H, 13 pins, pitch 5mm, size 65x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-13-5.0-H pitch 5mm size 65x9mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-14-3.5-H_1x14_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-14-3.5-H, 14 pins, pitch 3.5mm, size 49x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-14-3.5-H pitch 3.5mm size 49x7.6mm^2 drill 1.2mm pad 2.4mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-14-5.0-H_1x14_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-14-5.0-H, 14 pins, pitch 5mm, size 70x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-14-5.0-H pitch 5mm size 70x9mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-15-3.5-H_1x15_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-15-3.5-H, 15 pins, pitch 3.5mm, size 52.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-15-3.5-H pitch 3.5mm size 52.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-15-5.0-H_1x15_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-15-5.0-H, 15 pins, pitch 5mm, size 75x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-15-5.0-H pitch 5mm size 75x9mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-16-3.5-H_1x16_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-16-3.5-H, 16 pins, pitch 3.5mm, size 56x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-16-3.5-H pitch 3.5mm size 56x7.6mm^2 drill 1.2mm pad 2.4mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-16-5.0-H_1x16_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-16-5.0-H, 16 pins, pitch 5mm, size 80x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-16-5.0-H pitch 5mm size 80x9mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-2,5-V-SMD_1x02-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 2 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814702/pdf +PhoenixContact PTSM0.5 2 2.5mm vertical SMD spring clamp terminal block connector +0 +4 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-2.5-H-THR_1x02_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-2-2.5-H-THR, 2 pins, pitch 2.5mm, size 7.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-2-2.5-H-THR pitch 2.5mm size 7.2x10mm^2 drill 1.2mm pad 3mm +0 +4 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-2.5-V-THR_1x02_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-2-2.5-V-THR, vertical (cable from top), 2 pins, pitch 2.5mm, size 5.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-2-2.5-V-THR vertical pitch 2.5mm size 5.5x5mm^2 drill 1.2mm pad 2mm +0 +4 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-HV-2.5-SMD_1x02-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 2 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778696/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +4 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-2,5-V-SMD_1x03-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 3 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814715/pdf +PhoenixContact PTSM0.5 3 2.5mm vertical SMD spring clamp terminal block connector +0 +5 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-2.5-H-THR_1x03_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-3-2.5-H-THR, 3 pins, pitch 2.5mm, size 9.7x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-3-2.5-H-THR pitch 2.5mm size 9.7x10mm^2 drill 1.2mm pad 3mm +0 +6 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-2.5-V-THR_1x03_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-3-2.5-V-THR, vertical (cable from top), 3 pins, pitch 2.5mm, size 8x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-3-2.5-V-THR vertical pitch 2.5mm size 8x5mm^2 drill 1.2mm pad 2mm +0 +6 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-HV-2.5-SMD_1x03-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 3 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778706/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +5 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-2,5-V-SMD_1x04-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 4 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814728/pdf +PhoenixContact PTSM0.5 4 2.5mm vertical SMD spring clamp terminal block connector +0 +6 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-2.5-H-THR_1x04_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-4-2.5-H-THR, 4 pins, pitch 2.5mm, size 12.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-4-2.5-H-THR pitch 2.5mm size 12.2x10mm^2 drill 1.2mm pad 3mm +0 +8 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-2.5-V-THR_1x04_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-4-2.5-V-THR, vertical (cable from top), 4 pins, pitch 2.5mm, size 10.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-4-2.5-V-THR vertical pitch 2.5mm size 10.5x5mm^2 drill 1.2mm pad 2mm +0 +8 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-HV-2.5-SMD_1x04-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 4 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778719/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +4 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-2,5-V-SMD_1x05-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 5 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814731/pdf +PhoenixContact PTSM0.5 5 2.5mm vertical SMD spring clamp terminal block connector +0 +7 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-2.5-H-THR_1x05_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-5-2.5-H-THR, 5 pins, pitch 2.5mm, size 14.7x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-5-2.5-H-THR pitch 2.5mm size 14.7x10mm^2 drill 1.2mm pad 3mm +0 +10 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-2.5-V-THR_1x05_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-5-2.5-V-THR, vertical (cable from top), 5 pins, pitch 2.5mm, size 13x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-5-2.5-V-THR vertical pitch 2.5mm size 13x5mm^2 drill 1.2mm pad 2mm +0 +10 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-HV-2.5-SMD_1x05-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 5 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778722/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +7 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-2,5-V-SMD_1x06-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 6 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814744/pdf +PhoenixContact PTSM0.5 6 2.5mm vertical SMD spring clamp terminal block connector +0 +8 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-2.5-H-THR_1x06_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-6-2.5-H-THR, 6 pins, pitch 2.5mm, size 17.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-6-2.5-H-THR pitch 2.5mm size 17.2x10mm^2 drill 1.2mm pad 3mm +0 +12 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-2.5-V-THR_1x06_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-6-2.5-V-THR, vertical (cable from top), 6 pins, pitch 2.5mm, size 15.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-6-2.5-V-THR vertical pitch 2.5mm size 15.5x5mm^2 drill 1.2mm pad 2mm +0 +12 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-HV-2.5-SMD_1x06-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 6 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778735/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +8 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-2,5-V-SMD_1x07-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 7 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814757/pdf +PhoenixContact PTSM0.5 7 2.5mm vertical SMD spring clamp terminal block connector +0 +9 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-2.5-H-THR_1x07_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-7-2.5-H-THR, 7 pins, pitch 2.5mm, size 19.7x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-7-2.5-H-THR pitch 2.5mm size 19.7x10mm^2 drill 1.2mm pad 3mm +0 +14 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-2.5-V-THR_1x07_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-7-2.5-V-THR, vertical (cable from top), 7 pins, pitch 2.5mm, size 18x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-7-2.5-V-THR vertical pitch 2.5mm size 18x5mm^2 drill 1.2mm pad 2mm +0 +14 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-HV-2.5-SMD_1x07-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 7 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778748/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +9 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-2,5-V-SMD_1x08-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 8 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814760/pdf +PhoenixContact PTSM0.5 8 2.5mm vertical SMD spring clamp terminal block connector +0 +10 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-2.5-H-THR_1x08_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-8-2.5-H-THR, 8 pins, pitch 2.5mm, size 22.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-8-2.5-H-THR pitch 2.5mm size 22.2x10mm^2 drill 1.2mm pad 3mm +0 +16 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-2.5-V-THR_1x08_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-8-2.5-V-THR, vertical (cable from top), 8 pins, pitch 2.5mm, size 20.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-8-2.5-V-THR vertical pitch 2.5mm size 20.5x5mm^2 drill 1.2mm pad 2mm +0 +16 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-HV-2.5-SMD_1x08-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 8 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778751/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +10 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00001_1x02_P5.00mm_Horizontal +terminal block RND 205-00001, 2 pins, pitch 5mm, size 10x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00001 pitch 5mm size 10x9mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00002_1x03_P5.00mm_Horizontal +terminal block RND 205-00002, 3 pins, pitch 5mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00002 pitch 5mm size 15x9mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00003_1x04_P5.00mm_Horizontal +terminal block RND 205-00003, 4 pins, pitch 5mm, size 20x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00003 pitch 5mm size 20x9mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00004_1x05_P5.00mm_Horizontal +terminal block RND 205-00004, 5 pins, pitch 5mm, size 25x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00004 pitch 5mm size 25x9mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00005_1x06_P5.00mm_Horizontal +terminal block RND 205-00005, 6 pins, pitch 5mm, size 30x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00005 pitch 5mm size 30x9mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00006_1x07_P5.00mm_Horizontal +terminal block RND 205-00006, 7 pins, pitch 5mm, size 35x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00006 pitch 5mm size 35x9mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00007_1x08_P5.00mm_Horizontal +terminal block RND 205-00007, 8 pins, pitch 5mm, size 40x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00007 pitch 5mm size 40x9mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00008_1x09_P5.00mm_Horizontal +terminal block RND 205-00008, 9 pins, pitch 5mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00008 pitch 5mm size 45x9mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00009_1x10_P5.00mm_Horizontal +terminal block RND 205-00009, 10 pins, pitch 5mm, size 50x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00009 pitch 5mm size 50x9mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00010_1x11_P5.00mm_Horizontal +terminal block RND 205-00010, 11 pins, pitch 5mm, size 55x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00010 pitch 5mm size 55x9mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00011_1x12_P5.00mm_Horizontal +terminal block RND 205-00011, 12 pins, pitch 5mm, size 60x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00011 pitch 5mm size 60x9mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00012_1x02_P5.00mm_Horizontal +terminal block RND 205-00012, 2 pins, pitch 5mm, size 10x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00012 pitch 5mm size 10x7.6mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00013_1x03_P5.00mm_Horizontal +terminal block RND 205-00013, 3 pins, pitch 5mm, size 15x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00013 pitch 5mm size 15x7.6mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00014_1x04_P5.00mm_Horizontal +terminal block RND 205-00014, 4 pins, pitch 5mm, size 20x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00014 pitch 5mm size 20x7.6mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00015_1x05_P5.00mm_Horizontal +terminal block RND 205-00015, 5 pins, pitch 5mm, size 25x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00015 pitch 5mm size 25x7.6mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00016_1x06_P5.00mm_Horizontal +terminal block RND 205-00016, 6 pins, pitch 5mm, size 30x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00016 pitch 5mm size 30x7.6mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00017_1x07_P5.00mm_Horizontal +terminal block RND 205-00017, 7 pins, pitch 5mm, size 35x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00017 pitch 5mm size 35x7.6mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00018_1x08_P5.00mm_Horizontal +terminal block RND 205-00018, 8 pins, pitch 5mm, size 40x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00018 pitch 5mm size 40x7.6mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00019_1x09_P5.00mm_Horizontal +terminal block RND 205-00019, 9 pins, pitch 5mm, size 45x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00019 pitch 5mm size 45x7.6mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00020_1x10_P5.00mm_Horizontal +terminal block RND 205-00020, 10 pins, pitch 5mm, size 50x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00020 pitch 5mm size 50x7.6mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00021_1x11_P5.00mm_Horizontal +terminal block RND 205-00021, 11 pins, pitch 5mm, size 55x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00021 pitch 5mm size 55x7.6mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00022_1x12_P5.00mm_Horizontal +terminal block RND 205-00022, 12 pins, pitch 5mm, size 60x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00022 pitch 5mm size 60x7.6mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00023_1x02_P10.00mm_Horizontal +terminal block RND 205-00023, 2 pins, pitch 10mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00023 pitch 10mm size 15x9mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00024_1x03_P10.00mm_Horizontal +terminal block RND 205-00024, 3 pins, pitch 10mm, size 25x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00024 pitch 10mm size 25x9mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00025_1x04_P10.00mm_Horizontal +terminal block RND 205-00025, 4 pins, pitch 10mm, size 35x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00025 pitch 10mm size 35x9mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00026_1x05_P10.00mm_Horizontal +terminal block RND 205-00026, 5 pins, pitch 10mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00026 pitch 10mm size 45x9mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00027_1x06_P10.00mm_Horizontal +terminal block RND 205-00027, 6 pins, pitch 10mm, size 55x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00027 pitch 10mm size 55x9mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00028_1x07_P10.00mm_Horizontal +terminal block RND 205-00028, 7 pins, pitch 10mm, size 65x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00028 pitch 10mm size 65x9mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00029_1x08_P10.00mm_Horizontal +terminal block RND 205-00029, 8 pins, pitch 10mm, size 75x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00029 pitch 10mm size 75x9mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00030_1x09_P10.00mm_Horizontal +terminal block RND 205-00030, 9 pins, pitch 10mm, size 85x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00030 pitch 10mm size 85x9mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00031_1x10_P10.00mm_Horizontal +terminal block RND 205-00031, 10 pins, pitch 10mm, size 95x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00031 pitch 10mm size 95x9mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00032_1x11_P10.00mm_Horizontal +terminal block RND 205-00032, 11 pins, pitch 10mm, size 105x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00032 pitch 10mm size 105x9mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00033_1x12_P10.00mm_Horizontal +terminal block RND 205-00033, 12 pins, pitch 10mm, size 115x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00033 pitch 10mm size 115x9mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00045_1x02_P5.00mm_Horizontal +terminal block RND 205-00045, 2 pins, pitch 5mm, size 10x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00045 pitch 5mm size 10x8.1mm^2 drill 1.1mm pad 2.1mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00046_1x03_P5.00mm_Horizontal +terminal block RND 205-00046, 3 pins, pitch 5mm, size 15x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00046 pitch 5mm size 15x8.1mm^2 drill 1.1mm pad 2.1mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00047_1x04_P5.00mm_Horizontal +terminal block RND 205-00047, 4 pins, pitch 5mm, size 20x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00047 pitch 5mm size 20x8.1mm^2 drill 1.1mm pad 2.1mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00048_1x05_P5.00mm_Horizontal +terminal block RND 205-00048, 5 pins, pitch 5mm, size 25x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00048 pitch 5mm size 25x8.1mm^2 drill 1.1mm pad 2.1mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00049_1x06_P5.00mm_Horizontal +terminal block RND 205-00049, 6 pins, pitch 5mm, size 30x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00049 pitch 5mm size 30x8.1mm^2 drill 1.1mm pad 2.1mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00050_1x07_P5.00mm_Horizontal +terminal block RND 205-00050, 7 pins, pitch 5mm, size 35x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00050 pitch 5mm size 35x8.1mm^2 drill 1.1mm pad 2.1mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00051_1x08_P5.00mm_Horizontal +terminal block RND 205-00051, 8 pins, pitch 5mm, size 40x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00051 pitch 5mm size 40x8.1mm^2 drill 1.1mm pad 2.1mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00052_1x09_P5.00mm_Horizontal +terminal block RND 205-00052, 9 pins, pitch 5mm, size 45x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00052 pitch 5mm size 45x8.1mm^2 drill 1.1mm pad 2.1mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00053_1x10_P5.00mm_Horizontal +terminal block RND 205-00053, 10 pins, pitch 5mm, size 50x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00053 pitch 5mm size 50x8.1mm^2 drill 1.1mm pad 2.1mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00054_1x11_P5.00mm_Horizontal +terminal block RND 205-00054, 11 pins, pitch 5mm, size 55x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00054 pitch 5mm size 55x8.1mm^2 drill 1.1mm pad 2.1mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00055_1x12_P5.00mm_Horizontal +terminal block RND 205-00055, 12 pins, pitch 5mm, size 60x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00055 pitch 5mm size 60x8.1mm^2 drill 1.1mm pad 2.1mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00056_1x02_P5.00mm_45Degree +terminal block RND 205-00056, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 10x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00056 45Degree pitch 5mm size 10x12.6mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00057_1x03_P5.00mm_45Degree +terminal block RND 205-00057, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 15x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00057 45Degree pitch 5mm size 15x12.6mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00058_1x04_P5.00mm_45Degree +terminal block RND 205-00058, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 20x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00058 45Degree pitch 5mm size 20x12.6mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00059_1x05_P5.00mm_45Degree +terminal block RND 205-00059, 45Degree (cable under 45degree), 5 pins, pitch 5mm, size 25x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00059 45Degree pitch 5mm size 25x12.6mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00060_1x06_P5.00mm_45Degree +terminal block RND 205-00060, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 30x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00060 45Degree pitch 5mm size 30x12.6mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00061_1x07_P5.00mm_45Degree +terminal block RND 205-00061, 45Degree (cable under 45degree), 7 pins, pitch 5mm, size 35x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00061 45Degree pitch 5mm size 35x12.6mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00062_1x08_P5.00mm_45Degree +terminal block RND 205-00062, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 40x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00062 45Degree pitch 5mm size 40x12.6mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00063_1x09_P5.00mm_45Degree +terminal block RND 205-00063, 45Degree (cable under 45degree), 9 pins, pitch 5mm, size 45x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00063 45Degree pitch 5mm size 45x12.6mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00064_1x10_P5.00mm_45Degree +terminal block RND 205-00064, 45Degree (cable under 45degree), 10 pins, pitch 5mm, size 50x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00064 45Degree pitch 5mm size 50x12.6mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00065_1x11_P5.00mm_45Degree +terminal block RND 205-00065, 45Degree (cable under 45degree), 11 pins, pitch 5mm, size 55x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00065 45Degree pitch 5mm size 55x12.6mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00066_1x12_P5.00mm_45Degree +terminal block RND 205-00066, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 60x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00066 45Degree pitch 5mm size 60x12.6mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00067_1x02_P7.50mm_Horizontal +terminal block RND 205-00067, 2 pins, pitch 7.5mm, size 15x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00067 pitch 7.5mm size 15x10.3mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00068_1x03_P7.50mm_Horizontal +terminal block RND 205-00068, 3 pins, pitch 7.5mm, size 22.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00068 pitch 7.5mm size 22.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00069_1x04_P7.50mm_Horizontal +terminal block RND 205-00069, 4 pins, pitch 7.5mm, size 30x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00069 pitch 7.5mm size 30x10.3mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00070_1x05_P7.50mm_Horizontal +terminal block RND 205-00070, 5 pins, pitch 7.5mm, size 37.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00070 pitch 7.5mm size 37.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00071_1x06_P7.50mm_Horizontal +terminal block RND 205-00071, 6 pins, pitch 7.5mm, size 45x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00071 pitch 7.5mm size 45x10.3mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00072_1x07_P7.50mm_Horizontal +terminal block RND 205-00072, 7 pins, pitch 7.5mm, size 52.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00072 pitch 7.5mm size 52.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00073_1x08_P7.50mm_Horizontal +terminal block RND 205-00073, 8 pins, pitch 7.5mm, size 60x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00073 pitch 7.5mm size 60x10.3mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00074_1x09_P7.50mm_Horizontal +terminal block RND 205-00074, 9 pins, pitch 7.5mm, size 67.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00074 pitch 7.5mm size 67.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00075_1x10_P7.50mm_Horizontal +terminal block RND 205-00075, 10 pins, pitch 7.5mm, size 75x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00075 pitch 7.5mm size 75x10.3mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00076_1x11_P7.50mm_Horizontal +terminal block RND 205-00076, 11 pins, pitch 7.5mm, size 82.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00076 pitch 7.5mm size 82.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00077_1x12_P7.50mm_Horizontal +terminal block RND 205-00077, 12 pins, pitch 7.5mm, size 90x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00077 pitch 7.5mm size 90x10.3mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00078_1x02_P10.00mm_Horizontal +terminal block RND 205-00078, 2 pins, pitch 10mm, size 15x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00078 pitch 10mm size 15x10.3mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00079_1x03_P10.00mm_Horizontal +terminal block RND 205-00079, 3 pins, pitch 10mm, size 25x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00079 pitch 10mm size 25x10.3mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00080_1x04_P10.00mm_Horizontal +terminal block RND 205-00080, 4 pins, pitch 10mm, size 35x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00080 pitch 10mm size 35x10.3mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00081_1x05_P10.00mm_Horizontal +terminal block RND 205-00081, 5 pins, pitch 10mm, size 45x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00081 pitch 10mm size 45x10.3mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00082_1x06_P10.00mm_Horizontal +terminal block RND 205-00082, 6 pins, pitch 10mm, size 55x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00082 pitch 10mm size 55x10.3mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00083_1x07_P10.00mm_Horizontal +terminal block RND 205-00083, 7 pins, pitch 10mm, size 65x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00083 pitch 10mm size 65x10.3mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00084_1x08_P10.00mm_Horizontal +terminal block RND 205-00084, 8 pins, pitch 10mm, size 75x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00084 pitch 10mm size 75x10.3mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00085_1x09_P10.00mm_Horizontal +terminal block RND 205-00085, 9 pins, pitch 10mm, size 85x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00085 pitch 10mm size 85x10.3mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00086_1x10_P10.00mm_Horizontal +terminal block RND 205-00086, 10 pins, pitch 10mm, size 95x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00086 pitch 10mm size 95x10.3mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00087_1x11_P10.00mm_Horizontal +terminal block RND 205-00087, 11 pins, pitch 10mm, size 105x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00087 pitch 10mm size 105x10.3mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00088_1x12_P10.00mm_Horizontal +terminal block RND 205-00088, 12 pins, pitch 10mm, size 115x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00088 pitch 10mm size 115x10.3mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00232_1x02_P5.08mm_Horizontal +terminal block RND 205-00232, 2 pins, pitch 5.08mm, size 10.2x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00232 pitch 5.08mm size 10.2x8.45mm^2 drill 1.1mm pad 2.1mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00233_1x03_P5.08mm_Horizontal +terminal block RND 205-00233, 3 pins, pitch 5.08mm, size 15.2x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00233 pitch 5.08mm size 15.2x8.45mm^2 drill 1.1mm pad 2.1mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00234_1x04_P5.08mm_Horizontal +terminal block RND 205-00234, 4 pins, pitch 5.08mm, size 20.3x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00234 pitch 5.08mm size 20.3x8.45mm^2 drill 1.1mm pad 2.1mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00235_1x05_P5.08mm_Horizontal +terminal block RND 205-00235, 5 pins, pitch 5.08mm, size 25.4x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00235 pitch 5.08mm size 25.4x8.45mm^2 drill 1.1mm pad 2.1mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00236_1x06_P5.08mm_Horizontal +terminal block RND 205-00236, 6 pins, pitch 5.08mm, size 30.5x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00236 pitch 5.08mm size 30.5x8.45mm^2 drill 1.1mm pad 2.1mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00237_1x07_P5.08mm_Horizontal +terminal block RND 205-00237, 7 pins, pitch 5.08mm, size 35.6x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00237 pitch 5.08mm size 35.6x8.45mm^2 drill 1.1mm pad 2.1mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00238_1x08_P5.08mm_Horizontal +terminal block RND 205-00238, 8 pins, pitch 5.08mm, size 40.6x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00238 pitch 5.08mm size 40.6x8.45mm^2 drill 1.1mm pad 2.1mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00239_1x09_P5.08mm_Horizontal +terminal block RND 205-00239, 9 pins, pitch 5.08mm, size 45.7x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00239 pitch 5.08mm size 45.7x8.45mm^2 drill 1.1mm pad 2.1mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00240_1x10_P5.08mm_Horizontal +terminal block RND 205-00240, 10 pins, pitch 5.08mm, size 50.8x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00240 pitch 5.08mm size 50.8x8.45mm^2 drill 1.1mm pad 2.1mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00241_1x02_P10.16mm_Horizontal +terminal block RND 205-00241, 2 pins, pitch 10.2mm, size 15.2x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00241 pitch 10.2mm size 15.2x8.3mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00242_1x03_P10.16mm_Horizontal +terminal block RND 205-00242, 3 pins, pitch 10.2mm, size 25.4x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00242 pitch 10.2mm size 25.4x8.3mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00243_1x04_P10.16mm_Horizontal +terminal block RND 205-00243, 4 pins, pitch 10.2mm, size 35.6x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00243 pitch 10.2mm size 35.6x8.3mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00244_1x05_P10.16mm_Horizontal +terminal block RND 205-00244, 5 pins, pitch 10.2mm, size 45.7x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00244 pitch 10.2mm size 45.7x8.3mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00245_1x06_P10.16mm_Horizontal +terminal block RND 205-00245, 6 pins, pitch 10.2mm, size 55.9x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00245 pitch 10.2mm size 55.9x8.3mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00246_1x07_P10.16mm_Horizontal +terminal block RND 205-00246, 7 pins, pitch 10.2mm, size 66x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00246 pitch 10.2mm size 66x8.3mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00247_1x08_P10.16mm_Horizontal +terminal block RND 205-00247, 8 pins, pitch 10.2mm, size 76.2x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00247 pitch 10.2mm size 76.2x8.3mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00248_1x09_P10.16mm_Horizontal +terminal block RND 205-00248, 9 pins, pitch 10.2mm, size 86.4x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00248 pitch 10.2mm size 86.4x8.3mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00249_1x10_P10.16mm_Horizontal +terminal block RND 205-00249, 10 pins, pitch 10.2mm, size 96.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00249 pitch 10.2mm size 96.5x8.3mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00250_1x11_P10.16mm_Horizontal +terminal block RND 205-00250, 11 pins, pitch 10.2mm, size 107x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00250 pitch 10.2mm size 107x8.3mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00251_1x12_P10.16mm_Horizontal +terminal block RND 205-00251, 12 pins, pitch 10.2mm, size 117x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00251 pitch 10.2mm size 117x8.3mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00276_1x02_P5.00mm_Vertical +terminal block RND 205-00078, vertical (cable from top), 2 pins, pitch 5mm, size 10x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00078 vertical pitch 5mm size 10x10mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00277_1x03_P5.00mm_Vertical +terminal block RND 205-00079, vertical (cable from top), 3 pins, pitch 5mm, size 15x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00079 vertical pitch 5mm size 15x10mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00278_1x04_P5.00mm_Vertical +terminal block RND 205-00080, vertical (cable from top), 4 pins, pitch 5mm, size 20x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00080 vertical pitch 5mm size 20x10mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00279_1x05_P5.00mm_Vertical +terminal block RND 205-00081, vertical (cable from top), 5 pins, pitch 5mm, size 25x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00081 vertical pitch 5mm size 25x10mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00280_1x06_P5.00mm_Vertical +terminal block RND 205-00082, vertical (cable from top), 6 pins, pitch 5mm, size 30x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00082 vertical pitch 5mm size 30x10mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00281_1x07_P5.00mm_Vertical +terminal block RND 205-00083, vertical (cable from top), 7 pins, pitch 5mm, size 35x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00083 vertical pitch 5mm size 35x10mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00282_1x08_P5.00mm_Vertical +terminal block RND 205-00084, vertical (cable from top), 8 pins, pitch 5mm, size 40x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00084 vertical pitch 5mm size 40x10mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00283_1x09_P5.00mm_Vertical +terminal block RND 205-00085, vertical (cable from top), 9 pins, pitch 5mm, size 45x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00085 vertical pitch 5mm size 45x10mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00284_1x10_P5.00mm_Vertical +terminal block RND 205-00086, vertical (cable from top), 10 pins, pitch 5mm, size 50x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00086 vertical pitch 5mm size 50x10mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00285_1x11_P5.00mm_Vertical +terminal block RND 205-00087, vertical (cable from top), 11 pins, pitch 5mm, size 55x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00087 vertical pitch 5mm size 55x10mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00286_1x12_P5.00mm_Vertical +terminal block RND 205-00088, vertical (cable from top), 12 pins, pitch 5mm, size 60x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00088 vertical pitch 5mm size 60x10mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00287_1x02_P5.08mm_Horizontal +terminal block RND 205-00287, 2 pins, pitch 5.08mm, size 10.2x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00287 pitch 5.08mm size 10.2x10.6mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00288_1x03_P5.08mm_Horizontal +terminal block RND 205-00288, 3 pins, pitch 5.08mm, size 15.2x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00288 pitch 5.08mm size 15.2x10.6mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00289_1x04_P5.08mm_Horizontal +terminal block RND 205-00289, 4 pins, pitch 5.08mm, size 20.3x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00289 pitch 5.08mm size 20.3x10.6mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00290_1x05_P5.08mm_Horizontal +terminal block RND 205-00290, 5 pins, pitch 5.08mm, size 25.4x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00290 pitch 5.08mm size 25.4x10.6mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00291_1x06_P5.08mm_Horizontal +terminal block RND 205-00291, 6 pins, pitch 5.08mm, size 30.5x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00291 pitch 5.08mm size 30.5x10.6mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00292_1x07_P5.08mm_Horizontal +terminal block RND 205-00292, 7 pins, pitch 5.08mm, size 35.6x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00292 pitch 5.08mm size 35.6x10.6mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00293_1x08_P5.08mm_Horizontal +terminal block RND 205-00293, 8 pins, pitch 5.08mm, size 40.6x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00293 pitch 5.08mm size 40.6x10.6mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00294_1x09_P5.08mm_Horizontal +terminal block RND 205-00294, 9 pins, pitch 5.08mm, size 45.7x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00294 pitch 5.08mm size 45.7x10.6mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00295_1x10_P5.08mm_Horizontal +terminal block RND 205-00295, 10 pins, pitch 5.08mm, size 50.8x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00295 pitch 5.08mm size 50.8x10.6mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00296_1x11_P5.08mm_Horizontal +terminal block RND 205-00296, 11 pins, pitch 5.08mm, size 55.9x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00296 pitch 5.08mm size 55.9x10.6mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00297_1x12_P5.08mm_Horizontal +terminal block RND 205-00297, 12 pins, pitch 5.08mm, size 61x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00297 pitch 5.08mm size 61x10.6mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00298_1x02_P10.00mm_Horizontal +terminal block RND 205-00298, 2 pins, pitch 10mm, size 15x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00298 pitch 10mm size 15x8.1mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00299_1x03_P10.00mm_Horizontal +terminal block RND 205-00299, 3 pins, pitch 10mm, size 25x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00299 pitch 10mm size 25x8.1mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00300_1x04_P10.00mm_Horizontal +terminal block RND 205-00300, 4 pins, pitch 10mm, size 35x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00300 pitch 10mm size 35x8.1mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00301_1x05_P10.00mm_Horizontal +terminal block RND 205-00301, 5 pins, pitch 10mm, size 45x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00301 pitch 10mm size 45x8.1mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00302_1x06_P10.00mm_Horizontal +terminal block RND 205-00302, 6 pins, pitch 10mm, size 55x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00302 pitch 10mm size 55x8.1mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00303_1x07_P10.00mm_Horizontal +terminal block RND 205-00303, 7 pins, pitch 10mm, size 65x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00303 pitch 10mm size 65x8.1mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00304_1x08_P10.00mm_Horizontal +terminal block RND 205-00304, 8 pins, pitch 10mm, size 75x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00304 pitch 10mm size 75x8.1mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00305_1x09_P10.00mm_Horizontal +terminal block RND 205-00305, 9 pins, pitch 10mm, size 85x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00305 pitch 10mm size 85x8.1mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00306_1x10_P10.00mm_Horizontal +terminal block RND 205-00306, 10 pins, pitch 10mm, size 95x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00306 pitch 10mm size 95x8.1mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00307_1x11_P10.00mm_Horizontal +terminal block RND 205-00307, 11 pins, pitch 10mm, size 105x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00307 pitch 10mm size 105x8.1mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00308_1x12_P10.00mm_Horizontal +terminal block RND 205-00308, 12 pins, pitch 10mm, size 115x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00308 pitch 10mm size 115x8.1mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_1-282834-0_1x10_P2.54mm_Horizontal +Terminal Block TE 1-282834-0, 10 pins, pitch 2.54mm, size 25.86x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 1-282834-0 pitch 2.54mm size 25.86x6.5mm^2 drill 1.1mm pad 2.1mm +0 +10 +10 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_1-282834-1_1x11_P2.54mm_Horizontal +Terminal Block TE 1-282834-1, 11 pins, pitch 2.54mm, size 28.4x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 1-282834-1 pitch 2.54mm size 28.4x6.5mm^2 drill 1.1mm pad 2.1mm +0 +11 +11 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_1-282834-2_1x12_P2.54mm_Horizontal +Terminal Block TE 1-282834-2, 12 pins, pitch 2.54mm, size 30.94x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 1-282834-2 pitch 2.54mm size 30.94x6.5mm^2 drill 1.1mm pad 2.1mm +0 +12 +12 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-2_1x02_P2.54mm_Horizontal +Terminal Block TE 282834-2, 2 pins, pitch 2.54mm, size 5.54x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-2 pitch 2.54mm size 5.54x6.5mm^2 drill 1.1mm pad 2.1mm +0 +2 +2 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-3_1x03_P2.54mm_Horizontal +Terminal Block TE 282834-3, 3 pins, pitch 2.54mm, size 8.08x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-3 pitch 2.54mm size 8.08x6.5mm^2 drill 1.1mm pad 2.1mm +0 +3 +3 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-4_1x04_P2.54mm_Horizontal +Terminal Block TE 282834-4, 4 pins, pitch 2.54mm, size 10.620000000000001x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-4 pitch 2.54mm size 10.620000000000001x6.5mm^2 drill 1.1mm pad 2.1mm +0 +4 +4 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-5_1x05_P2.54mm_Horizontal +Terminal Block TE 282834-5, 5 pins, pitch 2.54mm, size 13.16x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-5 pitch 2.54mm size 13.16x6.5mm^2 drill 1.1mm pad 2.1mm +0 +5 +5 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-6_1x06_P2.54mm_Horizontal +Terminal Block TE 282834-6, 6 pins, pitch 2.54mm, size 15.7x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-6 pitch 2.54mm size 15.7x6.5mm^2 drill 1.1mm pad 2.1mm +0 +6 +6 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-7_1x07_P2.54mm_Horizontal +Terminal Block TE 282834-7, 7 pins, pitch 2.54mm, size 18.240000000000002x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-7 pitch 2.54mm size 18.240000000000002x6.5mm^2 drill 1.1mm pad 2.1mm +0 +7 +7 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-8_1x08_P2.54mm_Horizontal +Terminal Block TE 282834-8, 8 pins, pitch 2.54mm, size 20.78x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-8 pitch 2.54mm size 20.78x6.5mm^2 drill 1.1mm pad 2.1mm +0 +8 +8 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-9_1x09_P2.54mm_Horizontal +Terminal Block TE 282834-9, 9 pins, pitch 2.54mm, size 23.32x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-9 pitch 2.54mm size 23.32x6.5mm^2 drill 1.1mm pad 2.1mm +0 +9 +9 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-101_1x01_P5.00mm_45Degree +Terminal Block WAGO 236-101, 45Degree (cable under 45degree), 1 pins, pitch 5mm, size 7.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-101 45Degree pitch 5mm size 7.3x14mm^2 drill 1.15mm pad 3mm +0 +1 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-102_1x02_P5.00mm_45Degree +Terminal Block WAGO 236-102, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-102 45Degree pitch 5mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-103_1x03_P5.00mm_45Degree +Terminal Block WAGO 236-103, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-103 45Degree pitch 5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +3 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-104_1x04_P5.00mm_45Degree +Terminal Block WAGO 236-104, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-104 45Degree pitch 5mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-106_1x06_P5.00mm_45Degree +Terminal Block WAGO 236-106, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-106 45Degree pitch 5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-108_1x08_P5.00mm_45Degree +Terminal Block WAGO 236-108, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-108 45Degree pitch 5mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-112_1x12_P5.00mm_45Degree +Terminal Block WAGO 236-112, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-112 45Degree pitch 5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-116_1x16_P5.00mm_45Degree +Terminal Block WAGO 236-116, 45Degree (cable under 45degree), 16 pins, pitch 5mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-116 45Degree pitch 5mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-124_1x24_P5.00mm_45Degree +Terminal Block WAGO 236-124, 45Degree (cable under 45degree), 24 pins, pitch 5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-124 45Degree pitch 5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +24 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-136_1x36_P5.00mm_45Degree +Terminal Block WAGO 236-136, 45Degree (cable under 45degree), 36 pins, pitch 5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-136 45Degree pitch 5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +36 +36 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-148_1x48_P5.00mm_45Degree +Terminal Block WAGO 236-148, 45Degree (cable under 45degree), 48 pins, pitch 5mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-148 45Degree pitch 5mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +48 +48 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-201_1x01_P7.50mm_45Degree +Terminal Block WAGO 236-201, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 9.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-201 45Degree pitch 7.5mm size 9.8x14mm^2 drill 1.15mm pad 3mm +0 +1 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-202_1x02_P7.50mm_45Degree +Terminal Block WAGO 236-202, 45Degree (cable under 45degree), 2 pins, pitch 7.5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-202 45Degree pitch 7.5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-203_1x03_P7.50mm_45Degree +Terminal Block WAGO 236-203, 45Degree (cable under 45degree), 3 pins, pitch 7.5mm, size 24.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-203 45Degree pitch 7.5mm size 24.8x14mm^2 drill 1.15mm pad 3mm +0 +3 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-204_1x04_P7.50mm_45Degree +Terminal Block WAGO 236-204, 45Degree (cable under 45degree), 4 pins, pitch 7.5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-204 45Degree pitch 7.5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-206_1x06_P7.50mm_45Degree +Terminal Block WAGO 236-206, 45Degree (cable under 45degree), 6 pins, pitch 7.5mm, size 47.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-206 45Degree pitch 7.5mm size 47.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-208_1x08_P7.50mm_45Degree +Terminal Block WAGO 236-208, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-208 45Degree pitch 7.5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-212_1x12_P7.50mm_45Degree +Terminal Block WAGO 236-212, 45Degree (cable under 45degree), 12 pins, pitch 7.5mm, size 92.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-212 45Degree pitch 7.5mm size 92.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-216_1x16_P7.50mm_45Degree +Terminal Block WAGO 236-216, 45Degree (cable under 45degree), 16 pins, pitch 7.5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-216 45Degree pitch 7.5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +16 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-224_1x24_P7.50mm_45Degree +Terminal Block WAGO 236-224, 45Degree (cable under 45degree), 24 pins, pitch 7.5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-224 45Degree pitch 7.5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +24 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-301_1x01_P10.00mm_45Degree +Terminal Block WAGO 236-301, 45Degree (cable under 45degree), 1 pins, pitch 10mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-301 45Degree pitch 10mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +1 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-302_1x02_P10.00mm_45Degree +Terminal Block WAGO 236-302, 45Degree (cable under 45degree), 2 pins, pitch 10mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-302 45Degree pitch 10mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-303_1x03_P10.00mm_45Degree +Terminal Block WAGO 236-303, 45Degree (cable under 45degree), 3 pins, pitch 10mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-303 45Degree pitch 10mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +3 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-304_1x04_P10.00mm_45Degree +Terminal Block WAGO 236-304, 45Degree (cable under 45degree), 4 pins, pitch 10mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-304 45Degree pitch 10mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-306_1x06_P10.00mm_45Degree +Terminal Block WAGO 236-306, 45Degree (cable under 45degree), 6 pins, pitch 10mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-306 45Degree pitch 10mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-308_1x08_P10.00mm_45Degree +Terminal Block WAGO 236-308, 45Degree (cable under 45degree), 8 pins, pitch 10mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-308 45Degree pitch 10mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-312_1x12_P10.00mm_45Degree +Terminal Block WAGO 236-312, 45Degree (cable under 45degree), 12 pins, pitch 10mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-312 45Degree pitch 10mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +12 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-316_1x16_P10.00mm_45Degree +Terminal Block WAGO 236-316, 45Degree (cable under 45degree), 16 pins, pitch 10mm, size 162x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-316 45Degree pitch 10mm size 162x14mm^2 drill 1.15mm pad 3mm +0 +16 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-324_1x24_P10.00mm_45Degree +Terminal Block WAGO 236-324, 45Degree (cable under 45degree), 24 pins, pitch 10mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-324 45Degree pitch 10mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +24 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-401_1x01_P5.00mm_45Degree +Terminal Block WAGO 236-401, 45Degree (cable under 45degree), 1 pins, pitch 5mm, size 7.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-401 45Degree pitch 5mm size 7.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-402_1x02_P5.00mm_45Degree +Terminal Block WAGO 236-402, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-402 45Degree pitch 5mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-403_1x03_P5.00mm_45Degree +Terminal Block WAGO 236-403, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-403 45Degree pitch 5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-404_1x04_P5.00mm_45Degree +Terminal Block WAGO 236-404, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-404 45Degree pitch 5mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-406_1x06_P5.00mm_45Degree +Terminal Block WAGO 236-406, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-406 45Degree pitch 5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-408_1x08_P5.00mm_45Degree +Terminal Block WAGO 236-408, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-408 45Degree pitch 5mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-412_1x12_P5.00mm_45Degree +Terminal Block WAGO 236-412, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-412 45Degree pitch 5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-416_1x16_P5.00mm_45Degree +Terminal Block WAGO 236-416, 45Degree (cable under 45degree), 16 pins, pitch 5mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-416 45Degree pitch 5mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-424_1x24_P5.00mm_45Degree +Terminal Block WAGO 236-424, 45Degree (cable under 45degree), 24 pins, pitch 5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-424 45Degree pitch 5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-436_1x36_P5.00mm_45Degree +Terminal Block WAGO 236-436, 45Degree (cable under 45degree), 36 pins, pitch 5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-436 45Degree pitch 5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +72 +36 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-448_1x48_P5.00mm_45Degree +Terminal Block WAGO 236-448, 45Degree (cable under 45degree), 48 pins, pitch 5mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-448 45Degree pitch 5mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +96 +48 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-501_1x01_P7.50mm_45Degree +Terminal Block WAGO 236-501, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 9.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-501 45Degree pitch 7.5mm size 9.8x14mm^2 drill 1.15mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-502_1x02_P7.50mm_45Degree +Terminal Block WAGO 236-502, 45Degree (cable under 45degree), 2 pins, pitch 7.5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-502 45Degree pitch 7.5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-503_1x03_P7.50mm_45Degree +Terminal Block WAGO 236-503, 45Degree (cable under 45degree), 3 pins, pitch 7.5mm, size 24.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-503 45Degree pitch 7.5mm size 24.8x14mm^2 drill 1.15mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-504_1x04_P7.50mm_45Degree +Terminal Block WAGO 236-504, 45Degree (cable under 45degree), 4 pins, pitch 7.5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-504 45Degree pitch 7.5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-506_1x06_P7.50mm_45Degree +Terminal Block WAGO 236-506, 45Degree (cable under 45degree), 6 pins, pitch 7.5mm, size 47.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-506 45Degree pitch 7.5mm size 47.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-508_1x08_P7.50mm_45Degree +Terminal Block WAGO 236-508, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-508 45Degree pitch 7.5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-512_1x12_P7.50mm_45Degree +Terminal Block WAGO 236-512, 45Degree (cable under 45degree), 12 pins, pitch 7.5mm, size 92.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-512 45Degree pitch 7.5mm size 92.3x14mm^2 drill 1.15mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-516_1x16_P7.50mm_45Degree +Terminal Block WAGO 236-516, 45Degree (cable under 45degree), 16 pins, pitch 7.5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-516 45Degree pitch 7.5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-524_1x24_P7.50mm_45Degree +Terminal Block WAGO 236-524, 45Degree (cable under 45degree), 24 pins, pitch 7.5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-524 45Degree pitch 7.5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-601_1x01_P10.00mm_45Degree +Terminal Block WAGO 236-601, 45Degree (cable under 45degree), 1 pins, pitch 10mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-601 45Degree pitch 10mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-602_1x02_P10.00mm_45Degree +Terminal Block WAGO 236-602, 45Degree (cable under 45degree), 2 pins, pitch 10mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-602 45Degree pitch 10mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-603_1x03_P10.00mm_45Degree +Terminal Block WAGO 236-603, 45Degree (cable under 45degree), 3 pins, pitch 10mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-603 45Degree pitch 10mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-604_1x04_P10.00mm_45Degree +Terminal Block WAGO 236-604, 45Degree (cable under 45degree), 4 pins, pitch 10mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-604 45Degree pitch 10mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-606_1x06_P10.00mm_45Degree +Terminal Block WAGO 236-606, 45Degree (cable under 45degree), 6 pins, pitch 10mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-606 45Degree pitch 10mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-608_1x08_P10.00mm_45Degree +Terminal Block WAGO 236-608, 45Degree (cable under 45degree), 8 pins, pitch 10mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-608 45Degree pitch 10mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-612_1x12_P10.00mm_45Degree +Terminal Block WAGO 236-612, 45Degree (cable under 45degree), 12 pins, pitch 10mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-612 45Degree pitch 10mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-616_1x16_P10.00mm_45Degree +Terminal Block WAGO 236-616, 45Degree (cable under 45degree), 16 pins, pitch 10mm, size 162x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-616 45Degree pitch 10mm size 162x14mm^2 drill 1.15mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-624_1x24_P10.00mm_45Degree +Terminal Block WAGO 236-624, 45Degree (cable under 45degree), 24 pins, pitch 10mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-624 45Degree pitch 10mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-101_1x01_P5.00mm_45Degree +Terminal Block WAGO 804-101, 45Degree (cable under 45degree), 1 pins, pitch 5mm, size 6.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-101 45Degree pitch 5mm size 6.5x15mm^2 drill 1.2mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-102_1x02_P5.00mm_45Degree +Terminal Block WAGO 804-102, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 11.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-102 45Degree pitch 5mm size 11.5x15mm^2 drill 1.2mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-103_1x03_P5.00mm_45Degree +Terminal Block WAGO 804-103, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 16.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-103 45Degree pitch 5mm size 16.5x15mm^2 drill 1.2mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-104_1x04_P5.00mm_45Degree +Terminal Block WAGO 804-104, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 21.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-104 45Degree pitch 5mm size 21.5x15mm^2 drill 1.2mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-105_1x05_P5.00mm_45Degree +Terminal Block WAGO 804-105, 45Degree (cable under 45degree), 5 pins, pitch 5mm, size 26.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-105 45Degree pitch 5mm size 26.5x15mm^2 drill 1.2mm pad 3mm +0 +10 +5 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-106_1x06_P5.00mm_45Degree +Terminal Block WAGO 804-106, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 31.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-106 45Degree pitch 5mm size 31.5x15mm^2 drill 1.2mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-107_1x07_P5.00mm_45Degree +Terminal Block WAGO 804-107, 45Degree (cable under 45degree), 7 pins, pitch 5mm, size 36.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-107 45Degree pitch 5mm size 36.5x15mm^2 drill 1.2mm pad 3mm +0 +14 +7 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-108_1x08_P5.00mm_45Degree +Terminal Block WAGO 804-108, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 41.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-108 45Degree pitch 5mm size 41.5x15mm^2 drill 1.2mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-109_1x09_P5.00mm_45Degree +Terminal Block WAGO 804-109, 45Degree (cable under 45degree), 9 pins, pitch 5mm, size 46.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-109 45Degree pitch 5mm size 46.5x15mm^2 drill 1.2mm pad 3mm +0 +18 +9 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-110_1x10_P5.00mm_45Degree +Terminal Block WAGO 804-110, 45Degree (cable under 45degree), 10 pins, pitch 5mm, size 51.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-110 45Degree pitch 5mm size 51.5x15mm^2 drill 1.2mm pad 3mm +0 +20 +10 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-112_1x12_P5.00mm_45Degree +Terminal Block WAGO 804-112, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 61.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-112 45Degree pitch 5mm size 61.5x15mm^2 drill 1.2mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-116_1x16_P5.00mm_45Degree +Terminal Block WAGO 804-116, 45Degree (cable under 45degree), 16 pins, pitch 5mm, size 81.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-116 45Degree pitch 5mm size 81.5x15mm^2 drill 1.2mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-124_1x24_P5.00mm_45Degree +Terminal Block WAGO 804-124, 45Degree (cable under 45degree), 24 pins, pitch 5mm, size 122x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-124 45Degree pitch 5mm size 122x15mm^2 drill 1.2mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-301_1x01_P7.50mm_45Degree +Terminal Block WAGO 804-301, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 6.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-301 45Degree pitch 7.5mm size 6.5x15mm^2 drill 1.2mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-302_1x02_P7.50mm_45Degree +Terminal Block WAGO 804-302, 45Degree (cable under 45degree), 2 pins, pitch 7.5mm, size 14x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-302 45Degree pitch 7.5mm size 14x15mm^2 drill 1.2mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-303_1x03_P7.50mm_45Degree +Terminal Block WAGO 804-303, 45Degree (cable under 45degree), 3 pins, pitch 7.5mm, size 21.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-303 45Degree pitch 7.5mm size 21.5x15mm^2 drill 1.2mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-304_1x04_P7.50mm_45Degree +Terminal Block WAGO 804-304, 45Degree (cable under 45degree), 4 pins, pitch 7.5mm, size 29x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-304 45Degree pitch 7.5mm size 29x15mm^2 drill 1.2mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-305_1x05_P7.50mm_45Degree +Terminal Block WAGO 804-305, 45Degree (cable under 45degree), 5 pins, pitch 7.5mm, size 36.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-305 45Degree pitch 7.5mm size 36.5x15mm^2 drill 1.2mm pad 3mm +0 +10 +5 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-306_1x06_P7.50mm_45Degree +Terminal Block WAGO 804-306, 45Degree (cable under 45degree), 6 pins, pitch 7.5mm, size 44x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-306 45Degree pitch 7.5mm size 44x15mm^2 drill 1.2mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-307_1x07_P7.50mm_45Degree +Terminal Block WAGO 804-307, 45Degree (cable under 45degree), 7 pins, pitch 7.5mm, size 51.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-307 45Degree pitch 7.5mm size 51.5x15mm^2 drill 1.2mm pad 3mm +0 +14 +7 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-308_1x08_P7.50mm_45Degree +Terminal Block WAGO 804-308, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 59x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-308 45Degree pitch 7.5mm size 59x15mm^2 drill 1.2mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-309_1x09_P7.50mm_45Degree +Terminal Block WAGO 804-309, 45Degree (cable under 45degree), 9 pins, pitch 7.5mm, size 66.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-309 45Degree pitch 7.5mm size 66.5x15mm^2 drill 1.2mm pad 3mm +0 +18 +9 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-310_1x10_P7.50mm_45Degree +Terminal Block WAGO 804-310, 45Degree (cable under 45degree), 10 pins, pitch 7.5mm, size 74x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-310 45Degree pitch 7.5mm size 74x15mm^2 drill 1.2mm pad 3mm +0 +20 +10 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-312_1x12_P7.50mm_45Degree +Terminal Block WAGO 804-312, 45Degree (cable under 45degree), 12 pins, pitch 7.5mm, size 89x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-312 45Degree pitch 7.5mm size 89x15mm^2 drill 1.2mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-316_1x16_P7.50mm_45Degree +Terminal Block WAGO 804-316, 45Degree (cable under 45degree), 16 pins, pitch 7.5mm, size 119x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-316 45Degree pitch 7.5mm size 119x15mm^2 drill 1.2mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-324_1x24_P7.50mm_45Degree +Terminal Block WAGO 804-324, 45Degree (cable under 45degree), 24 pins, pitch 7.5mm, size 179x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-324 45Degree pitch 7.5mm size 179x15mm^2 drill 1.2mm pad 3mm +0 +48 +24 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650073_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650073.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650074_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650074.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650094_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650094.pdf) +screw terminal thread redcube thr power connector +0 +16 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650173_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650173.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650174_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650174.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650194_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650194.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650195_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650195.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74655095_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74655095.pdf) +screw terminal thread redcube thr power connector +0 +16 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651173_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651173.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651174_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651174.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651175_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651175.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651194_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651194.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651195_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651195.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TestPoint +TestPoint_2Pads_Pitch2.54mm_Drill0.8mm +Test point with 2 pins, pitch 2.54mm, drill diameter 0.8mm +CONN DEV +0 +2 +2 +TestPoint +TestPoint_2Pads_Pitch5.08mm_Drill1.3mm +Test point with 2 pads, pitch 5.08mm, hole diameter 1.3mm, wire diameter 1.0mm +CONN DEV +0 +2 +2 +TestPoint +TestPoint_Bridge_Pitch2.0mm_Drill0.7mm +wire loop as test point, pitch 2.0mm, hole diameter 0.7mm, wire diameter 0.5mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch2.54mm_Drill0.7mm +wire loop as test point, pitch 2.0mm, hole diameter 0.7mm, wire diameter 0.5mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch2.54mm_Drill1.0mm +wire loop as test point, pitch 2.54mm, hole diameter 1.0mm, wire diameter 0.8mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch2.54mm_Drill1.3mm +wire loop as test point, pitch 2.54mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch3.81mm_Drill1.3mm +wire loop as test point, pitch 3.81mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch5.08mm_Drill0.7mm +wire loop as test point, pitch 5.08mm, hole diameter 0.7mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch5.08mm_Drill1.3mm +wire loop as test point, pitch 5.08mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch6.35mm_Drill1.3mm +wire loop as test point, pitch 6.35mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch7.62mm_Drill1.3mm +wire loop as test point, pitch 7.62mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Keystone_5000-5004_Miniature +Keystone Miniature THM Test Point 5000-5004, http://www.keyelco.com/product-pdf.cfm?p=1309 +Through Hole Mount Test Points +0 +1 +1 +TestPoint +TestPoint_Keystone_5005-5009_Compact +Keystone Miniature THM Test Point 5005-5009, http://www.keyelco.com/product-pdf.cfm?p=1314 +Through Hole Mount Test Points +0 +1 +1 +TestPoint +TestPoint_Keystone_5010-5014_Multipurpose +Keystone Miniature THM Test Point 5010-5014, http://www.keyelco.com/product-pdf.cfm?p=1319 +Through Hole Mount Test Points +0 +1 +1 +TestPoint +TestPoint_Keystone_5015_Micro-Minature +SMT Test Point- Micro Miniature 5015, http://www.keyelco.com/product-pdf.cfm?p=1353 +Test Point +0 +1 +1 +TestPoint +TestPoint_Keystone_5019_Minature +SMT Test Point- Micro Miniature 5019, http://www.keyelco.com/product-pdf.cfm?p=1357 +Test Point +0 +1 +1 +TestPoint +TestPoint_Loop_D1.80mm_Drill1.0mm_Beaded +wire loop with bead as test point, loop diameter 1.8mm, hole diameter 1.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.50mm_Drill1.0mm +wire loop as test point, loop diameter 2.5mm, hole diameter 1.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.50mm_Drill1.0mm_LowProfile +low profile wire loop as test point, loop diameter 2.5mm, hole diameter 1.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.50mm_Drill1.85mm +wire loop as test point, loop diameter 2.5mm, hole diameter 1.85mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.54mm_Drill1.5mm_Beaded +wire loop with bead as test point, loop diameter2.548mm, hole diameter 1.5mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.60mm_Drill0.9mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 0.9mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.60mm_Drill1.4mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 1.4mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.60mm_Drill1.6mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 1.6mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.50mm_Drill0.9mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 0.9mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.50mm_Drill1.4mm_Beaded +wire loop with bead as test point, loop diameter 3.5mm, hole diameter 1.4mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.80mm_Drill2.0mm +wire loop as test point, loop diameter 3.8mm, hole diameter 2.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.80mm_Drill2.5mm +wire loop as test point, loop diameter 3.8mm, hole diameter 2.5mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.80mm_Drill2.8mm +wire loop as test point, loop diameter 3.8mm, hole diameter 2.8mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Pad_1.0x1.0mm +SMD rectangular pad as test Point, square 1.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_1.5x1.5mm +SMD rectangular pad as test Point, square 1.5mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_2.0x2.0mm +SMD rectangular pad as test Point, square 2.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_2.5x2.5mm +SMD rectangular pad as test Point, square 2.5mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_3.0x3.0mm +SMD rectangular pad as test Point, square 3.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_4.0x4.0mm +SMD rectangular pad as test Point, square 4.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_D1.0mm +SMD pad as test Point, diameter 1.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D1.5mm +SMD pad as test Point, diameter 1.5mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D2.0mm +SMD pad as test Point, diameter 2.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D2.5mm +SMD pad as test Point, diameter 2.5mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D3.0mm +SMD pad as test Point, diameter 3.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D4.0mm +SMD pad as test Point, diameter 4.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D2.0mm +Plated Hole as test Point, diameter 2.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D3.0mm +Plated Hole as test Point, diameter 3.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D4.0mm +Plated Hole as test Point, diameter 4.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D5.0mm +Plated Hole as test Point, diameter 5.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_THTPad_1.0x1.0mm_Drill0.5mm +THT rectangular pad as test Point, square 1.0mm side length, hole diameter 0.5mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_1.5x1.5mm_Drill0.7mm +THT rectangular pad as test Point, square 1.5mm side length, hole diameter 0.7mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_2.0x2.0mm_Drill1.0mm +THT rectangular pad as test Point, square 2.0mm_Drill1.0mm side length, hole diameter 1.0mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_2.5x2.5mm_Drill1.2mm +THT rectangular pad as test Point, square 2.5mm side length, hole diameter 1.2mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_3.0x3.0mm_Drill1.5mm +THT rectangular pad as test Point, square 3.0mm side length, hole diameter 1.5mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_4.0x4.0mm_Drill2.0mm +THT rectangular pad as test Point, square 4.0mm side length, hole diameter 2.0mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_D1.0mm_Drill0.5mm +THT pad as test Point, diameter 1.0mm, hole diameter 0.5mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D1.5mm_Drill0.7mm +THT pad as test Point, diameter 1.5mm, hole diameter 0.7mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D2.0mm_Drill1.0mm +THT pad as test Point, diameter 2.0mm, hole diameter 1.0mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D2.5mm_Drill1.2mm +THT pad as test Point, diameter 2.5mm, hole diameter 1.2mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D3.0mm_Drill1.5mm +THT pad as test Point, diameter 3.0mm, hole diameter 1.5mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D4.0mm_Drill2.0mm +THT pad as test Point, diameter 4.0mm, hole diameter 2.0mm +test point THT pad +0 +1 +1 +Transformer_SMD +Pulse_P0926NL +SMT Gate Drive Transformer, 1:1:1, 8.0x6.3x5.3mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa0926nl +0 +6 +6 +Transformer_SMD +Pulse_PA1323NL +SMT Gate Drive Transformer, 1:1, 9.5x7.1x5.3mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa1323nl +0 +6 +6 +Transformer_SMD +Pulse_PA2001NL +SMT Gate Drive Transformer, 1:1, 8.6x6.7x2.5mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2001nl pe-68386nl +0 +4 +4 +Transformer_SMD +Pulse_PA2002NL-PA2008NL-PA2009NL +SMT Gate Drive Transformer, 1:1:1 or 2:1:1 or 2.5:1:1 or 1:1, 9.0x8.6x7.6mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2002nl pa2008nl pa2009nl p0544nl pa0184nl pa0297nl pa0510nl +0 +6 +6 +Transformer_SMD +Pulse_PA2004NL +SMT Gate Drive Transformer, 1:1:1, 8.6x6.7x3.6mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2004nl pa0264nl +0 +6 +6 +Transformer_SMD +Pulse_PA2005NL +SMT Gate Drive Transformer, 1:1:1, 11.8x8.8x4.0mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2005nl pa0173nl +0 +6 +6 +Transformer_SMD +Pulse_PA2006NL +SMT Gate Drive Transformer, 1:1, 11.8x8.8x4.0mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2006nl pa0186nl +0 +4 +4 +Transformer_SMD +Pulse_PA2007NL +SMT Gate Drive Transformer, 1:1, 9.0x8.6x7.6mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2007nl +0 +4 +4 +Transformer_SMD +Pulse_PA2777NL +SMT Gate Drive Transformer, 1:1, 7.1x6.1x5.5mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa2777nl +0 +8 +8 +Transformer_SMD +Pulse_PA3493NL +SMT Gate Drive Transformer, 1.25:1, 10.9x9.7x2.7mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa3493nl +0 +4 +4 +Transformer_SMD +Transformer_Coilcraft_CST1 +Current sense transformer, SMD, 8.0x8.13x5.3mm (https://www.coilcraft.com/pdfs/cst.pdf) +Transformer current sense SMD +0 +8 +8 +Transformer_SMD +Transformer_Coilcraft_CST2 +Current sense transformer, SMD, 8.0x8.13x5.3mm (https://www.coilcraft.com/pdfs/cst.pdf) +Transformer current sense SMD +0 +8 +8 +Transformer_SMD +Transformer_Coilcraft_CST2010 +Current sense transformer, SMD, 14.55x19.91x10.50mm (https://www.coilcraft.com/pdfs/cst2010.pdf) +Transformer current sense SMD +0 +12 +12 +Transformer_SMD +Transformer_CurrentSense_8.4x7.2mm +Transformer current sense SMD 8.4x7.2mm +Transformer current sense SMD +0 +8 +8 +Transformer_SMD +Transformer_Ethernet_Bel_S558-5999-T7-F +Ethernet Transformer, Bel S558-5999-T7-F, https://www.belfuse.com/resources/ICMs/lan-/S558-5999-T7-F.pdf +Ethernet Transformer +0 +16 +16 +Transformer_SMD +Transformer_Ethernet_Bourns_PT61017PEL +https://www.bourns.com/docs/Product-Datasheets/PT61017PEL.pdf +Transformer Ethernet Single Center-Tap +0 +16 +16 +Transformer_SMD +Transformer_Ethernet_HALO_TG111-MSC13 +Transformer Ethernet SMD, https://www.haloelectronics.com/pdf/discrete-genesus.pdf +Transformer Ethernet SMD +0 +24 +24 +Transformer_SMD +Transformer_MACOM_SM-22 +https://cdn.macom.com/datasheets/ETC1-1-13.pdf +RF Transformer +0 +5 +5 +Transformer_SMD +Transformer_Murata_78250JC +Murata 78250JC https://www.murata-ps.com/datasheet?/data/magnetics/kmp_78250j.pdf +Murata transformer +0 +6 +6 +Transformer_SMD +Transformer_NF_ETAL_P2781 +NF-Transformer, ETAL, P2781, SMD, +NF-Transformer ETAL P2781 SMD +0 +8 +7 +Transformer_SMD +Transformer_NF_ETAL_P2781_HandSoldering +NF-Transformer, ETAL, P2781, SMD, Handsoldering +NF-Transformer ETAL P2781 SMD Handsoldering +0 +8 +7 +Transformer_SMD +Transformer_NF_ETAL_P3000 +NF-Reansformer, ETAL, P3000, SMD, +NF-Reansformer ETAL P3000 SMD +0 +15 +13 +Transformer_SMD +Transformer_NF_ETAL_P3000_HandSoldering +NF-Reansformer, ETAL, P3000, SMD, Handsoldering, +NF-Reansformer ETAL P3000 SMD Handsoldering +0 +15 +13 +Transformer_SMD +Transformer_NF_ETAL_P3181 +NF-Transformer, ETAL, P3181, SMD, +NF-Transformer ETAL P3181 SMD +0 +7 +6 +Transformer_SMD +Transformer_NF_ETAL_P3181_HandSoldering +NF-Transformer, ETAL, P3181, SMD, Hand Soldering, +NF-Transformer ETAL P3181 SMD Hand Soldering +0 +7 +6 +Transformer_SMD +Transformer_NF_ETAL_P3188 +NF-Transformer, ETAL, P3188, SMD, +NF-Transformer ETAL P3188 SMD +0 +8 +6 +Transformer_SMD +Transformer_NF_ETAL_P3188_HandSoldering +NF-Transformer, ETAL, P3188, SMD, Handsoldering, +NF-Transformer ETAL P3188 SMD Handsoldering +0 +8 +6 +Transformer_SMD +Transformer_NF_ETAL_P3191 +NF-Transformer, ETAL, P3191, SMD, +NF-Transformer ETAL P3191 SMD +0 +8 +6 +Transformer_SMD +Transformer_NF_ETAL_P3191_HandSoldering +NF-Transformer, ETAL, P3191, SMD, Handsoldering, +NF-Transformer ETAL P3191 SMD Handsoldering +0 +8 +6 +Transformer_SMD +Transformer_Pulse_H1100NL +For H1100NL, H1101NL, H1102NL, H1121NL, H1183NL, H1199NL, HX1188NL, HX1198NL and H1302NL. https://productfinder.pulseeng.com/doc_type/WEB301/doc_num/H1102NL/doc_part/H1102NL.pdf +H1100NL H1101NL H1102NL H1121NL H1183NL H1199NL HX1188NL HX1198NL H1302N +0 +16 +16 +Transformer_SMD +Transformer_Wuerth_750315371 +Power Transformer, horizontal core with bobbin, 6 pin, 2.54mm pitch, 11.24mm row spacing, 12.6x8.3x4.1mm +transformer flyback +0 +6 +6 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D9.0mm_Amidon-T30 +Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 9mm, Amidon T30, +Autotransformer Toroid horizontal laying 1 Tap Diameter 9mm Amidon T30 +0 +3 +3 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D10.5mm_Amidon-T37 +Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 10,5mm, Amidon T37, +Autotransformer Toroid horizontal laying 1 Tap Diameter 10 5mm Amidon T37 +0 +3 +3 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D12.5mm_Amidon-T44 +Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 12,5mm, Amidon T44, +Autotransformer Toroid horizontal laying 1 Tap Diameter 12 5mm Amidon T44 +0 +3 +3 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D14.0mm_Amidon-T50 +Choke, Inductance, Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 14mm, Amidon T50, +Choke Inductance Autotransformer Toroid horizontal laying 1 Tap Diameter 14mm Amidon T50 +0 +3 +3 +Transformer_THT +Autotransformer_ZS1052-AC +Ignition coil for xenon flash, http://www.excelitas.com/downloads/ZS1052ACH.pdf +ignition coil autotransformer +0 +3 +3 +Transformer_THT +Transformer_37x44 +transformer 37x44mm² +transformer 37x44mm² +0 +12 +4 +Transformer_THT +Transformer_Breve_TEZ-22x24 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +7 +7 +Transformer_THT +Transformer_Breve_TEZ-28x33 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +9 +9 +Transformer_THT +Transformer_Breve_TEZ-35x42 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +9 +9 +Transformer_THT +Transformer_Breve_TEZ-38x45 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +9 +9 +Transformer_THT +Transformer_Breve_TEZ-44x52 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +10 +10 +Transformer_THT +Transformer_Breve_TEZ-47x57 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +13 +13 +Transformer_THT +Transformer_CHK_EI30-2VA_1xSec +Trafo, Printtrafo, CHK, EI30, 2VA, 1x Sec,http://www.eratransformers.com/downloads/030-7585.0.pdf +Trafo Printtrafo CHK EI30 2VA 1x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI30-2VA_2xSec +Trafo, Printtrafo, CHK, EI30, 2VA, 2x Sec, +Trafo Printtrafo CHK EI30 2VA 2x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI30-2VA_Neutral +Trafo, Printtrafo, CHK, EI30, 2VA, neutral, +Trafo Printtrafo CHK EI30 2VA neutral +0 +10 +10 +Transformer_THT +Transformer_CHK_EI38-3VA_1xSec +Trafo, Printtrafo, CHK, EI38, 3VA, 1x Sec, http://www.eratransformers.com/product-detail/20 +Trafo Printtrafo CHK EI38 3VA 1x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI38-3VA_2xSec +Trafo, Printtrafo, CHK, EI38, 3VA, 2x Sec, http://www.eratransformers.com/product-detail/20 +Trafo Printtrafo CHK EI38 3VA 2x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI38-3VA_Neutral +Trafo, Printtrafo, CHK, EI38, 3VA, neutral, http://www.eratransformers.com/product-detail/20 +Trafo Printtrafo CHK EI42 3VA neutral +0 +10 +10 +Transformer_THT +Transformer_CHK_EI42-5VA_1xSec +Trafo, Printtrafo, CHK, EI42, 5VA, 1x Sec, +Trafo Printtrafo CHK EI42 5VA 1x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI42-5VA_2xSec +Trafo, Printtrafo, CHK, EI42, 5VA, 2x Sec, +Trafo Printtrafo CHK EI42 5VA 2x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI42-5VA_Neutral +Trafo, Printtrafo, CHK, EI42, 5VA, neutral, +Trafo Printtrafo CHK EI42 5VA neutral +0 +10 +10 +Transformer_THT +Transformer_CHK_EI48-8VA_1xSec +Trafo, Printtrafo, CHK, EI48, 8VA, 1x Sec, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 8VA 1x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-8VA_2xSec +Trafo, Printtrafo, CHK, EI48, 8VA, 2x Sec, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 8VA 2x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-8VA_Neutral +Trafo, Printtrafo, CHK, EI48, 8VA, neutral, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 8VA neutral +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-10VA_1xSec +Trafo, Printtrafo, CHK, EI48, 10VA, 1x Sec, +Trafo Printtrafo CHK EI48 10VA 1x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-10VA_2xSec +Trafo, Printtrafo, CHK, EI48, 10VA, 2x Sec, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 10VA 2x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-10VA_Neutral +Trafo, Printtrafo, CHK, EI48, 10VA, neutral, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 10VA neutral +0 +12 +12 +Transformer_THT +Transformer_CHK_EI54-12VA_1xSec +Trafo, Printtrafo, CHK, EI54, 12VA, 1x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 12VA 1x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-12VA_2xSec +Trafo, Printtrafo, CHK, EI54, 12VA, 2x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 12VA 2x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-12VA_Neutral +Trafo, Printtrafo, CHK, EI54, 12VA, neutral,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 12VA neutral +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-16VA_1xSec +Trafo, Printtrafo, CHK, EI54, 16VA, 1x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 16VA 1x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-16VA_2xSec +Trafo, Printtrafo, CHK, EI54, 16VA, 2x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 16VA 2x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-16VA_Neutral +Trafo, Printtrafo, CHK, EI54, 16VA, neutral,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 16VA neutral +0 +14 +14 +Transformer_THT +Transformer_CHK_UI30-4VA_Flat +Trafo, Flattrafo, CHK, UI30, 4VA, +Trafo Flattrafo CHK UI30 4VA +0 +16 +16 +Transformer_THT +Transformer_CHK_UI39-10VA_Flat +Trafo, Flattrafo, CHK, UI39, 10VA, +Trafo Flattrafo CHK UI39 10VA +0 +20 +20 +Transformer_THT +Transformer_Coilcraft_Q4434-B_Rhombus-T1311 +Transformator, Transformer, Flyback, Coilcraft Q4434-B, Rgombus T1311, +Transformator Transformer Flyback Coilcraft Q4434-B Rgombus T1311 +0 +8 +8 +Transformer_THT +Transformer_EPCOS_B66359A1013T_Horizontal +Transformer, Transformator, ETD29, 13 Pin, Horizontal, EPCOS-B66359A1013T, +Transformer Transformator ETD29 13 Pin Horizontal EPCOS-B66359A1013T +0 +13 +13 +Transformer_THT +Transformer_EPCOS_B66359J1014T_Vertical +Transformer, Transformator, ETD29, 14 Pin, Vertical, EPCOS-B66359J1014T, +Transformer Transformator ETD29 14 Pin Vertical EPCOS-B66359J1014T +0 +14 +14 +Transformer_THT +Transformer_Microphone_Lundahl_LL1538 +AUDIO TRAFO LUNDAHL, https://www.lundahltransformers.com/wp-content/uploads/datasheets/1538_8xl.pdf +AUDIO TRAFO LUNDAHL +0 +7 +7 +Transformer_THT +Transformer_Microphone_Lundahl_LL1587 +AUDIO TRAFO LUNDAHL, https://www.lundahltransformers.com/wp-content/uploads/datasheets/1587.pdf +AUDIO TRAFO LUNDAHL +0 +7 +7 +Transformer_THT +Transformer_Myrra_74040_Horizontal +Transformer, Transformator, ETD29, 13 Pin, Horizontal, Myrra-74040, +Transformer Transformator ETD29 13 Pin Horizontal Myrra-74040 +0 +13 +13 +Transformer_THT +Transformer_Myrra_EF20_7408x +EF20 flyback transformer,http://myrra.com/wp-content/uploads/2017/09/Datasheet-74087-74088-74089-rev-A.pdf +transformer flyback SMPS +0 +9 +9 +Transformer_THT +Transformer_NF_ETAL_1-1_P1200 +NF-Transformer, 1:1, ETAL P1200,http://www.etalgroup.com/sites/default/files/products/P1200_April_2005.pdf +NF-Transformer 1to1 ETAL P1200 +0 +4 +4 +Transformer_THT +Transformer_NF_ETAL_P1165 +NF-Transformer, ETAL, P1165,http://www.etalgroup.com/sites/default/files/products/P1165_February_2006.pdf +NF-Transformer ETAL P1165 +0 +4 +4 +Transformer_THT +Transformer_NF_ETAL_P3324 +NF-Transformer, ETAL P3324,http://www.etalgroup.com/sites/default/files/products/P3324_April_2005.pdf +NF-Transformer ETAL P3324 +0 +4 +4 +Transformer_THT +Transformer_NF_ETAL_P3356 +NF-Transformer, ETAL P3356, http://www.etalgroup.com/sites/default/files/products/P3356_December_2005.pdf +NF-Transformer ETAL P3356 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D9.0mm_Amidon-T30 +Transformer, Toroid, horizontal, laying, Diameter 9mm, Amidon, T30, +Transformer Toroid horizontal laying Diameter 9mm Amidon T30 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D10.5mm_Amidon-T37 +Transformer, Toroid, horizontal, laying, Diameter 10,5mm, Amidon T37, +Transformer Toroid horizontal laying Diameter 10 5mm Amidon T37 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D12.5mm_Amidon-T44 +Transformer, Toroid, horizontal, laying, Diameter 12,5mm, Amidon T44, +Transformer Toroid horizontal laying Diameter 12 5mm Amidon T44 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D14.0mm_Amidon-T50 +Transformer, Toroid, horizontal, laying, Diameter 14mm, Amidon T50, +Transformer Toroid horizontal laying Diameter 14mm Amidon T50 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D18.0mm +Transformer, Toroid, tapped, horizontal, laying, Diameter 18mm, +Transformer Toroid tapped horizontal laying Diameter 18mm +0 +5 +4 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D9.0mm_Amidon-T30 +Transformer, Toroid, tapped, horizontal, laying, Diameter 9mm, Amidon, T30, +Transformer Toroid tapped horizontal laying Diameter 9mm Amidon T30 +0 +6 +6 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D10.5mm_Amidon-T37 +Transformer, Toroid, tapped, horizontal, laying, Diameter 10,5mm, Amidon, T37, +Transformer Toroid tapped horizontal laying Diameter 10 5mm Amidon T37 +0 +6 +6 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D12.5mm_Amidon-T44 +Transformer, Toroid, tapped, horizontal, laying, Diameter 12,5mm, Amidon, T44, +Transformer Toroid tapped horizontal laying Diameter 12 5mm Amidon T44 +0 +6 +6 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D14.0mm_Amidon-T50 +Transformer, Toroid, tapped, horizontal, laying, Diameter 14mm, Amidon T50, +Transformer Toroid tapped horizontal laying Diameter 14mm Amidon T50 +0 +6 +6 +Transformer_THT +Transformer_Wuerth_750343373 +Transformer, horizontal core with bobbin, 10 pin, 3.81mm pitch, 15.24mm row spacing, 22x23x17.53mm (https://katalog.we-online.com/ctm/datasheet/750343373.pdf) +transformer flyback +0 +10 +10 +Valve +Valve_ECC-83-1 +Valve ECC-83-1 round pins +Valve ECC-83-1 round pins +0 +9 +9 +Valve +Valve_ECC-83-2 +Valve ECC-83-2 flat pins +Valve ECC-83-2 flat pins +0 +10 +9 +Valve +Valve_EURO +Valve Euro +Valve Euro +0 +7 +5 +Valve +Valve_Glimm +Valve Glimm +Valve Glimm +0 +2 +2 +Valve +Valve_Mini_G +Valve mini G +Valve mini G +0 +9 +7 +Valve +Valve_Mini_P +Valve mini P +Valve mini P +0 +7 +7 +Valve +Valve_Mini_Pentode_Linear +Mini-Pentode, 5-pin, e.g. JAN6418 +Valve Mini-Pentode 5-pin JAN6418 +0 +5 +5 +Valve +Valve_Noval_G +Valve NOVAL G +Valve NOVAL G +0 +11 +9 +Valve +Valve_Noval_P +Valve NOVAL P +Valve NOVAL P +0 +9 +9 +Valve +Valve_Octal +8-pin round valve +valve +0 +9 +8 +Varistor +RV_Disc_D7mm_W3.4mm_P5mm +Varistor, diameter 7mm, width 3.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.5mm_P5mm +Varistor, diameter 7mm, width 3.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.6mm_P5mm +Varistor, diameter 7mm, width 3.6mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.7mm_P5mm +Varistor, diameter 7mm, width 3.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.8mm_P5mm +Varistor, diameter 7mm, width 3.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.9mm_P5mm +Varistor, diameter 7mm, width 3.9mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.2mm_P5mm +Varistor, diameter 7mm, width 4.2mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.3mm_P5mm +Varistor, diameter 7mm, width 4.3mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.5mm_P5mm +Varistor, diameter 7mm, width 4.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.8mm_P5mm +Varistor, diameter 7mm, width 4.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.9mm_P5mm +Varistor, diameter 7mm, width 4.9mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4mm_P5mm +Varistor, diameter 7mm, width 4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.1mm_P5mm +Varistor, diameter 7mm, width 5.1mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.4mm_P5mm +Varistor, diameter 7mm, width 5.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.5mm_P5mm +Varistor, diameter 7mm, width 5.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.7mm_P5mm +Varistor, diameter 7mm, width 5.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.3mm_P5mm +Varistor, diameter 9mm, width 3.3mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.4mm_P5mm +Varistor, diameter 9mm, width 3.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.5mm_P5mm +Varistor, diameter 9mm, width 3.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.6mm_P5mm +Varistor, diameter 9mm, width 3.6mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.7mm_P5mm +Varistor, diameter 9mm, width 3.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.8mm_P5mm +Varistor, diameter 9mm, width 3.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.9mm_P5mm +Varistor, diameter 9mm, width 3.9mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.1mm_P5mm +Varistor, diameter 9mm, width 4.1mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.2mm_P5mm +Varistor, diameter 9mm, width 4.2mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.4mm_P5mm +Varistor, diameter 9mm, width 4.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.5mm_P5mm +Varistor, diameter 9mm, width 4.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.8mm_P5mm +Varistor, diameter 9mm, width 4.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4mm_P5mm +Varistor, diameter 9mm, width 4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.2mm_P5mm +Varistor, diameter 9mm, width 5.2mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.4mm_P5mm +Varistor, diameter 9mm, width 5.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.5mm_P5mm +Varistor, diameter 9mm, width 5.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.7mm_P5mm +Varistor, diameter 9mm, width 5.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W6.1mm_P5mm +Varistor, diameter 9mm, width 6.1mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W3.9mm_P7.5mm +Varistor, diameter 12mm, width 3.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.2mm_P7.5mm +Varistor, diameter 12mm, width 4.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.3mm_P7.5mm +Varistor, diameter 12mm, width 4.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.4mm_P7.5mm +Varistor, diameter 12mm, width 4.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.5mm_P7.5mm +Varistor, diameter 12mm, width 4.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.6mm_P7.5mm +Varistor, diameter 12mm, width 4.6mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.7mm_P7.5mm +Varistor, diameter 12mm, width 4.7mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.8mm_P7.5mm +Varistor, diameter 12mm, width 4.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4mm_P7.5mm +Varistor, diameter 12mm, width 4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5.1mm_P7.5mm +Varistor, diameter 12mm, width 5.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5.4mm_P7.5mm +Varistor, diameter 12mm, width 5.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5.8mm_P7.5mm +Varistor, diameter 12mm, width 5.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5mm_P7.5mm +Varistor, diameter 12mm, width 5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.1mm_P7.5mm +Varistor, diameter 12mm, width 6.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.2mm_P7.5mm +Varistor, diameter 12mm, width 6.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.3mm_P7.5mm +Varistor, diameter 12mm, width 6.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.7mm_P7.5mm +Varistor, diameter 12mm, width 6.7mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W7.1mm_P7.5mm +Varistor, diameter 12mm, width 7.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W7.5mm_P7.5mm +Varistor, diameter 12mm, width 7.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W7.9mm_P7.5mm +Varistor, diameter 12mm, width 7.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W3.9mm_P7.5mm +Varistor, diameter 15.5mm, width 3.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.2mm_P7.5mm +Varistor, diameter 15.5mm, width 4.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.3mm_P7.5mm +Varistor, diameter 15.5mm, width 4.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.4mm_P7.5mm +Varistor, diameter 15.5mm, width 4.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.5mm_P7.5mm +Varistor, diameter 15.5mm, width 4.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.6mm_P7.5mm +Varistor, diameter 15.5mm, width 4.6mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.7mm_P7.5mm +Varistor, diameter 15.5mm, width 4.7mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.8mm_P7.5mm +Varistor, diameter 15.5mm, width 4.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.9mm_P7.5mm +Varistor, diameter 15.5mm, width 4.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4mm_P7.5mm +Varistor, diameter 15.5mm, width 4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5.2mm_P7.5mm +Varistor, diameter 15.5mm, width 5.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5.4mm_P7.5mm +Varistor, diameter 15.5mm, width 5.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5.9mm_P7.5mm +Varistor, diameter 15.5mm, width 5.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5mm_P7.5mm +Varistor, diameter 15.5mm, width 5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.1mm_P7.5mm +Varistor, diameter 15.5mm, width 6.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.3mm_P7.5mm +Varistor, diameter 15.5mm, width 6.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.4mm_P7.5mm +Varistor, diameter 15.5mm, width 6.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.8mm_P7.5mm +Varistor, diameter 15.5mm, width 6.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W7.2mm_P7.5mm +Varistor, diameter 15.5mm, width 7.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W7.5mm_P7.5mm +Varistor, diameter 15.5mm, width 7.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W8mm_P7.5mm +Varistor, diameter 15.5mm, width 8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W11mm_P7.5mm +Varistor, diameter 15.5mm, width 11mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D16.5mm_W6.7mm_P7.5mm +Varistor, diameter 16.5mm, width 6.7mm, pitch 5mm, https://katalog.we-online.de/pbs/datasheet/820542711.pdf +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.3mm_P10mm +Varistor, diameter 21.5mm, width 4.3mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.4mm_P10mm +Varistor, diameter 21.5mm, width 4.4mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.5mm_P10mm +Varistor, diameter 21.5mm, width 4.5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.6mm_P10mm +Varistor, diameter 21.5mm, width 4.6mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.7mm_P10mm +Varistor, diameter 21.5mm, width 4.7mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.8mm_P10mm +Varistor, diameter 21.5mm, width 4.8mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.9mm_P10mm +Varistor, diameter 21.5mm, width 4.9mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.1mm_P10mm +Varistor, diameter 21.5mm, width 5.1mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.3mm_P10mm +Varistor, diameter 21.5mm, width 5.3mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.4mm_P10mm +Varistor, diameter 21.5mm, width 5.4mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.6mm_P10mm +Varistor, diameter 21.5mm, width 5.6mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.8mm_P10mm +Varistor, diameter 21.5mm, width 5.8mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5mm_P10mm +Varistor, diameter 21.5mm, width 5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.1mm_P7.5mm +varistor +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.3mm_P10mm +Varistor, diameter 21.5mm, width 6.3mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.5mm_P10mm +Varistor, diameter 21.5mm, width 6.5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.7mm_P10mm +Varistor, diameter 21.5mm, width 6.7mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.8mm_P10mm +Varistor, diameter 21.5mm, width 6.8mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W7.1mm_P10mm +Varistor, diameter 21.5mm, width 7.1mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W7.5mm_P10mm +Varistor, diameter 21.5mm, width 7.5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W7.9mm_P10mm +Varistor, diameter 21.5mm, width 7.9mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W8.4mm_P10mm +Varistor, diameter 21.5mm, width 8.4mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W11.4mm_P10mm +Varistor, diameter 21.5mm, width 11.4mm, pitch 10mm +varistor SIOV +0 +2 +2 diff --git a/Sofle_RGB_v3/Case/Sofle-RGB-tenting.svg b/Sofle_RGB_v3/Case/Sofle-RGB-tenting.svg new file mode 100644 index 00000000..38c2cc02 --- /dev/null +++ b/Sofle_RGB_v3/Case/Sofle-RGB-tenting.svg @@ -0,0 +1,868 @@ + + + + + SVG Picture created as SofleKeyboardTopPlate-brd.svg date 2021/06/29 14:41:24 + Picture generated by PCBNEW + + + + + + + SVG Picture created as SofleKeyboardTopPlate-brd.svg date 2021/06/29 14:41:24 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/Sofle_RGB_v3/Case/Sofle_RGB.svg b/Sofle_RGB_v3/Case/Sofle_RGB.svg new file mode 100644 index 00000000..4652dc8f --- /dev/null +++ b/Sofle_RGB_v3/Case/Sofle_RGB.svg @@ -0,0 +1,708 @@ + + + + + SVG Picture created as SofleKeyboardTopPlate-brd.svg date 2021/06/29 14:41:24 + Picture generated by PCBNEW + + + + + + + SVG Picture created as SofleKeyboardTopPlate-brd.svg date 2021/06/29 14:41:24 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/Sofle_RGB_v3/Case/oled_cover.svg b/Sofle_RGB_v3/Case/oled_cover.svg new file mode 100644 index 00000000..f623ac7f --- /dev/null +++ b/Sofle_RGB_v3/Case/oled_cover.svg @@ -0,0 +1,153 @@ + + + + + + + + + + + image/svg+xml + + + + + + + + + + + + + + + + + + + + + + + + + diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard-cache.lib b/Sofle_RGB_v3/PCB/SofleKeyboard-cache.lib new file mode 100644 index 00000000..3223be75 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard-cache.lib @@ -0,0 +1,387 @@ +EESchema-LIBRARY Version 2.4 +#encoding utf-8 +# +# SofleKeyboard-rescue_D-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_D-Lily58-cache-Lily58_Pro-rescue D 0 40 N N 1 F N +F0 "D" 0 100 50 H V C CNN +F1 "SofleKeyboard-rescue_D-Lily58-cache-Lily58_Pro-rescue" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + TO-???* + *_Diode_* + *SingleDiode* + D_* +$ENDFPLIST +DRAW +P 2 0 1 8 -50 50 -50 -50 N +P 2 0 1 0 50 0 -50 0 N +P 4 0 1 8 50 50 50 -50 -50 0 50 50 N +X K 1 -150 0 100 R 50 50 1 1 P +X A 2 150 0 100 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_GND-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_GND-Lily58-cache-Lily58_Pro-rescue #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -250 50 H I C CNN +F1 "SofleKeyboard-rescue_GND-Lily58-cache-Lily58_Pro-rescue" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 1 1 0 0 0 0 -50 50 -50 0 -100 -50 -50 0 -50 N +X GND 1 0 0 0 R 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_GND-power +# +DEF SofleKeyboard-rescue_GND-power #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -250 50 H I C CNN +F1 "SofleKeyboard-rescue_GND-power" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 0 1 0 0 0 0 -50 50 -50 0 -100 -50 -50 0 -50 N +X GND 1 0 0 0 D 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_HOLE-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_HOLE-Lily58-cache-Lily58_Pro-rescue U 0 40 Y Y 1 F N +F0 "U" 0 0 60 H V C CNN +F1 "SofleKeyboard-rescue_HOLE-Lily58-cache-Lily58_Pro-rescue" 0 -200 60 H V C CNN +F2 "" 0 0 60 H V C CNN +F3 "" 0 0 60 H V C CNN +DRAW +T 0 0 150 60 0 0 0 HOLE Normal 0 C C +S 150 200 -150 -150 0 1 0 N +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_Jumper-Device +# +DEF SofleKeyboard-rescue_Jumper-Device JP 0 30 Y N 1 F N +F0 "JP" 0 150 50 H V C CNN +F1 "SofleKeyboard-rescue_Jumper-Device" 0 -80 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + SolderJumper* +$ENDFPLIST +DRAW +A 0 -26 125 1426 373 0 1 0 N -98 50 99 50 +C -100 0 35 0 1 0 N +C 100 0 35 0 1 0 N +X 1 1 -300 0 165 R 50 50 0 1 P +X 2 2 300 0 165 L 50 50 0 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_Jumper_NO_Small-Device +# +DEF SofleKeyboard-rescue_Jumper_NO_Small-Device JP 0 30 N N 1 F N +F0 "JP" 0 80 50 H V C CNN +F1 "SofleKeyboard-rescue_Jumper_NO_Small-Device" 10 -60 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + SolderJumper*Open* +$ENDFPLIST +DRAW +C -40 0 20 0 1 0 N +C 40 0 20 0 1 0 N +X 1 1 -100 0 40 R 50 50 0 1 P +X 2 2 100 0 40 L 50 50 0 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_LED-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_LED-Lily58-cache-Lily58_Pro-rescue J 0 40 Y N 1 F N +F0 "J" 0 200 50 H V C CNN +F1 "SofleKeyboard-rescue_LED-Lily58-cache-Lily58_Pro-rescue" 0 -200 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + Connector*:*_??x*mm* + Connector*:*1x??x*mm* + Pin?Header?Straight?1X* + Pin?Header?Angled?1X* + Socket?Strip?Straight?1X* + Socket?Strip?Angled?1X* +$ENDFPLIST +DRAW +S -50 150 50 -150 1 1 10 f +S 0 -95 50 -105 1 1 6 N +S 0 5 50 -5 1 1 6 N +S 0 105 50 95 1 1 6 N +P 2 1 1 10 -50 -50 50 -50 N +P 2 1 1 10 -50 50 50 50 N +X Pin_1 1 200 100 150 L 50 50 1 1 P +X Pin_2 2 200 0 150 L 50 50 1 1 P +X Pin_3 3 200 -100 150 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue J 0 40 Y Y 1 F N +F0 "J" -350 -300 60 H V C CNN +F1 "SofleKeyboard-rescue_MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue" -150 250 60 H V C CNN +F2 "" 0 0 60 H V C CNN +F3 "" 0 0 60 H V C CNN +DRAW +S -300 100 -350 -150 0 1 0 N +S 300 -250 -400 200 0 1 0 N +P 2 0 1 0 100 0 300 0 N +P 3 0 1 0 -100 -200 300 -200 300 -200 N +P 3 0 1 0 0 -100 -50 -50 -100 -100 N +P 3 0 1 0 0 0 50 50 100 0 N +P 3 0 1 0 300 150 -300 150 -300 100 N +P 4 0 1 0 -100 -200 -150 -150 -200 -200 -200 -200 N +P 4 0 1 0 0 -100 300 -100 300 -100 300 -100 N +X ~ 1 450 0 150 L 50 50 1 1 P +X ~ 2 450 -100 150 L 50 50 1 1 P +X ~ 3 450 -200 150 L 50 50 1 1 P +X ~ 4 450 150 150 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_OLED-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_OLED-Lily58-cache-Lily58_Pro-rescue J 0 40 Y N 1 F N +F0 "J" 0 250 50 H V C CNN +F1 "SofleKeyboard-rescue_OLED-Lily58-cache-Lily58_Pro-rescue" 100 0 50 V V C CNN +F2 "" 0 0 50 H V C CNN +F3 "" 0 0 50 H V C CNN +$FPLIST + Pin_Header_Straight_1X04 + Pin_Header_Angled_1X04 + Socket_Strip_Straight_1X04 + Socket_Strip_Angled_1X04 +$ENDFPLIST +DRAW +S -50 -145 10 -155 0 1 0 N +S -50 -45 10 -55 0 1 0 N +S -50 55 10 45 0 1 0 N +S -50 155 10 145 0 1 0 N +S -50 200 50 -200 0 1 0 N +X P1 1 -200 150 150 R 50 50 1 1 P +X P2 2 -200 50 150 R 50 50 1 1 P +X P3 3 -200 -50 150 R 50 50 1 1 P +X P4 4 -200 -150 150 R 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_PWR_FLAG-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_PWR_FLAG-Lily58-cache-Lily58_Pro-rescue #FLG 0 0 N N 1 F P +F0 "#FLG" 0 0 50 H I C CNN +F1 "SofleKeyboard-rescue_PWR_FLAG-Lily58-cache-Lily58_Pro-rescue" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 0 1 0 0 0 0 50 -40 75 0 100 40 75 0 50 N +X pwr 1 0 0 0 U 50 50 0 0 w +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_ProMicro_2-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_ProMicro_2-Lily58-cache-Lily58_Pro-rescue U 0 40 Y Y 1 F N +F0 "U" 0 700 50 H V C CNN +F1 "SofleKeyboard-rescue_ProMicro_2-Lily58-cache-Lily58_Pro-rescue" 0 -700 50 H V C CNN +F2 "" -50 100 50 H I C CNN +F3 "" -50 100 50 H I C CNN +DRAW +S -450 650 450 -650 0 1 0 N +X TX(PD3) 1 -650 550 200 R 50 50 1 1 I +X D7(PE6) 10 -650 -350 200 R 50 50 1 1 I +X D8(PB4) 11 -650 -450 200 R 50 50 1 1 I +X D9(PB5) 12 -650 -550 200 R 50 50 1 1 I +X D10(PB6) 13 650 -550 200 L 50 50 1 1 I +X D16(PB2) 14 650 -450 200 L 50 50 1 1 I +X D14(PB3) 15 650 -350 200 L 50 50 1 1 I +X D15(PB1) 16 650 -250 200 L 50 50 1 1 I +X A0(PF7) 17 650 -150 200 L 50 50 1 1 I +X A1(PF6) 18 650 -50 200 L 50 50 1 1 I +X A2(PF5) 19 650 50 200 L 50 50 1 1 I +X RX(PD2) 2 -650 450 200 R 50 50 1 1 I +X A3(PF4) 20 650 150 200 L 50 50 1 1 I +X VCC 21 650 250 200 L 50 50 1 1 I +X RST 22 650 350 200 L 50 50 1 1 I +X GND 23 650 450 200 L 50 50 1 1 I +X RAW 24 650 550 200 L 50 50 1 1 I +X GND 3 -650 350 200 R 50 50 1 1 I +X GND 4 -650 250 200 R 50 50 1 1 I +X SDA(PD1) 5 -650 150 200 R 50 50 1 1 I +X SCL(PD0) 6 -650 50 200 R 50 50 1 1 I +X D4(PD4) 7 -650 -50 200 R 50 50 1 1 I +X D5(PC6) 8 -650 -150 200 R 50 50 1 1 I +X D6(PD7) 9 -650 -250 200 R 50 50 1 1 I +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_R-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_R-Lily58-cache-Lily58_Pro-rescue R 0 0 N Y 1 F N +F0 "R" 0 0 50 V V C CNN +F1 "SofleKeyboard-rescue_R-Lily58-cache-Lily58_Pro-rescue" -100 0 50 V V C CNN +F2 "" -70 0 50 V I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + R_* +$ENDFPLIST +DRAW +S -40 -100 40 100 0 1 10 N +X ~ 1 0 150 50 D 50 50 1 1 P +X ~ 2 0 -150 50 U 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_Rotary_Encoder_Switch-Device +# +DEF SofleKeyboard-rescue_Rotary_Encoder_Switch-Device SW 0 10 Y N 1 F N +F0 "SW" 0 260 50 H V C CNN +F1 "SofleKeyboard-rescue_Rotary_Encoder_Switch-Device" 0 -260 50 H V C CNN +F2 "" -150 160 50 H I C CNN +F3 "" 0 260 50 H I C CNN +$FPLIST + RotaryEncoder*Switch* +$ENDFPLIST +DRAW +A -15 -2 108 -899 899 0 1 10 N -15 -110 -15 105 +C -150 0 10 0 1 0 F +C -15 0 75 0 1 10 N +C 170 -40 5 0 1 10 N +C 170 40 5 0 1 10 N +S -200 200 200 -200 0 1 10 f +P 2 0 1 10 -25 -70 -25 70 N +P 2 0 1 10 -15 -70 -15 70 N +P 2 0 1 10 -5 70 -5 -70 N +P 2 0 1 10 150 0 135 0 N +P 2 0 1 10 150 40 150 -40 N +P 3 0 1 0 -200 -100 -150 -100 -150 -80 N +P 3 0 1 0 -200 100 -150 100 -150 80 N +P 3 0 1 10 10 -120 -20 -110 5 -95 N +P 3 0 1 10 10 115 -20 105 5 90 N +P 3 0 1 10 200 -100 170 -100 170 -40 N +P 3 0 1 10 200 100 170 100 170 40 N +P 4 0 1 0 -200 0 -150 0 -150 -40 -130 -80 N +P 4 0 1 0 -170 0 -150 0 -150 40 -130 80 N +X A A -300 100 100 R 50 50 1 1 P +X B B -300 -100 100 R 50 50 1 1 P +X C C -300 0 100 R 50 50 1 1 P +X S1 S1 300 100 100 L 50 50 1 1 P +X S2 S2 300 -100 100 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_SW_RST-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_SW_RST-Lily58-cache-Lily58_Pro-rescue RSW 0 40 N N 1 F N +F0 "RSW" 100 100 40 H V C CNN +F1 "SofleKeyboard-rescue_SW_RST-Lily58-cache-Lily58_Pro-rescue" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 2 0 1 0 -100 50 100 50 N +P 2 0 1 0 0 100 0 50 N +X 1 1 -150 0 100 R 50 50 0 1 P I +X 2 2 150 0 100 L 50 50 0 1 P I +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_VCC-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_VCC-Lily58-cache-Lily58_Pro-rescue #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -150 50 H I C CNN +F1 "SofleKeyboard-rescue_VCC-Lily58-cache-Lily58_Pro-rescue" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +C 0 75 25 0 1 0 N +P 2 0 1 0 0 0 0 50 N +X VCC 1 0 0 0 U 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_VCC-power +# +DEF SofleKeyboard-rescue_VCC-power #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -150 50 H I C CNN +F1 "SofleKeyboard-rescue_VCC-power" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +C 0 75 25 0 1 0 N +P 2 0 1 0 0 0 0 50 N +X VCC 1 0 0 0 U 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# SofleKeyboard-rescue_i2c_pin-Lily58-cache-Lily58_Pro-rescue +# +DEF SofleKeyboard-rescue_i2c_pin-Lily58-cache-Lily58_Pro-rescue J 0 40 Y N 1 F N +F0 "J" 0 100 50 H V C CNN +F1 "SofleKeyboard-rescue_i2c_pin-Lily58-cache-Lily58_Pro-rescue" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + Connector*:*_??x*mm* + Connector*:*1x??x*mm* + Pin?Header?Straight?1X* + Pin?Header?Angled?1X* + Socket?Strip?Straight?1X* + Socket?Strip?Angled?1X* +$ENDFPLIST +DRAW +S -50 5 0 -5 1 1 6 N +S -50 50 50 -50 1 1 10 f +X Pin_1 1 -200 0 150 R 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SofleKeyboard_LED_sk2812_SM +# +DEF SofleKeyboard_LED_sk2812_SM D 0 40 Y Y 1 F N +F0 "D" 0 150 50 H V C CNN +F1 "SofleKeyboard_LED_sk2812_SM" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +T 0 0 0 31 0 1 1 SK6812mini Normal 0 C C +S 150 -100 -150 100 1 1 0 f +X DOUT 1 -200 50 50 R 25 25 1 1 O +X VSS 2 -200 -50 50 R 25 25 1 1 W +X DIN 3 200 -50 50 L 25 25 1 1 I +X VDD 4 200 50 50 L 25 25 1 1 W +ENDDRAW +ENDDEF +# +# SofleKeyboard_SW_PUSH-MX_W_LED +# +DEF SofleKeyboard_SW_PUSH-MX_W_LED SW? 0 40 Y Y 2 L N +F0 "SW?" 0 150 50 H V C CNN +F1 "SofleKeyboard_SW_PUSH-MX_W_LED" 50 -150 25 H V C CNN +F2 "Button_Switch_Keyboard:SK6812MINI_and_cherry" 0 150 50 H I C CNN +F3 "" 0 150 50 H I C CNN +DRAW +T 0 0 0 31 0 2 0 SK6812mini Normal 0 C C +S -170 50 170 60 1 1 0 N +S 150 -100 -150 100 2 1 0 f +P 4 1 1 0 -40 60 -30 90 30 90 40 60 N +X ~ 5 300 0 200 L 25 24 1 1 P I +X ~ 6 -300 0 200 R 25 24 1 1 P I +X DOUT 1 -200 50 50 R 25 25 2 1 O +X VSS 2 -200 -50 50 R 25 25 2 1 W +X DIN 3 200 -50 50 L 25 25 2 1 I +X VDD 4 200 50 50 L 25 25 2 1 W +ENDDRAW +ENDDEF +# +#End Library diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard-rescue.lib b/Sofle_RGB_v3/PCB/SofleKeyboard-rescue.lib new file mode 100644 index 00000000..1ed838cd --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard-rescue.lib @@ -0,0 +1,642 @@ +EESchema-LIBRARY Version 2.4 +#encoding utf-8 +# +# D-Lily58-cache +# +DEF D-Lily58-cache D 0 40 N N 1 F N +F0 "D" 0 100 50 H V C CNN +F1 "D-Lily58-cache" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + TO-???* + *_Diode_* + *SingleDiode* + D_* +$ENDFPLIST +DRAW +P 2 0 1 8 -50 50 -50 -50 N +P 2 0 1 0 50 0 -50 0 N +P 4 0 1 8 50 50 50 -50 -50 0 50 50 N +X K 1 -150 0 100 R 50 50 1 1 P +X A 2 150 0 100 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# D-Lily58-cache-Lily58_Pro-rescue +# +DEF D-Lily58-cache-Lily58_Pro-rescue D 0 40 N N 1 F N +F0 "D" 0 100 50 H V C CNN +F1 "D-Lily58-cache-Lily58_Pro-rescue" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + TO-???* + *_Diode_* + *SingleDiode* + D_* +$ENDFPLIST +DRAW +P 2 0 1 8 -50 50 -50 -50 N +P 2 0 1 0 50 0 -50 0 N +P 4 0 1 8 50 50 50 -50 -50 0 50 50 N +X K 1 -150 0 100 R 50 50 1 1 P +X A 2 150 0 100 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# GND-Lily58-cache +# +DEF GND-Lily58-cache #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -250 50 H I C CNN +F1 "GND-Lily58-cache" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 1 1 0 0 0 0 -50 50 -50 0 -100 -50 -50 0 -50 N +X GND 1 0 0 0 R 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# GND-Lily58-cache-Lily58_Pro-rescue +# +DEF GND-Lily58-cache-Lily58_Pro-rescue #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -250 50 H I C CNN +F1 "GND-Lily58-cache-Lily58_Pro-rescue" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 1 1 0 0 0 0 -50 50 -50 0 -100 -50 -50 0 -50 N +X GND 1 0 0 0 R 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# GND-power +# +DEF GND-power #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -250 50 H I C CNN +F1 "GND-power" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 0 1 0 0 0 0 -50 50 -50 0 -100 -50 -50 0 -50 N +X GND 1 0 0 0 D 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# HOLE-Lily58-cache +# +DEF HOLE-Lily58-cache U 0 40 Y Y 1 F N +F0 "U" 0 0 60 H V C CNN +F1 "HOLE-Lily58-cache" 0 -200 60 H V C CNN +F2 "" 0 0 60 H V C CNN +F3 "" 0 0 60 H V C CNN +DRAW +T 0 0 150 60 0 0 0 HOLE Normal 0 C C +S 150 200 -150 -150 0 1 0 N +ENDDRAW +ENDDEF +# +# HOLE-Lily58-cache-Lily58_Pro-rescue +# +DEF HOLE-Lily58-cache-Lily58_Pro-rescue U 0 40 Y Y 1 F N +F0 "U" 0 0 60 H V C CNN +F1 "HOLE-Lily58-cache-Lily58_Pro-rescue" 0 -200 60 H V C CNN +F2 "" 0 0 60 H V C CNN +F3 "" 0 0 60 H V C CNN +DRAW +T 0 0 150 60 0 0 0 HOLE Normal 0 C C +S 150 200 -150 -150 0 1 0 N +ENDDRAW +ENDDEF +# +# Jumper-Device +# +DEF Jumper-Device JP 0 30 Y N 1 F N +F0 "JP" 0 150 50 H V C CNN +F1 "Jumper-Device" 0 -80 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + SolderJumper* +$ENDFPLIST +DRAW +A 0 -26 125 1426 373 0 1 0 N -98 50 99 50 +C -100 0 35 0 1 0 N +C 100 0 35 0 1 0 N +X 1 1 -300 0 165 R 50 50 0 1 P +X 2 2 300 0 165 L 50 50 0 1 P +ENDDRAW +ENDDEF +# +# Jumper_NO_Small-Device +# +DEF Jumper_NO_Small-Device JP 0 30 N N 1 F N +F0 "JP" 0 80 50 H V C CNN +F1 "Jumper_NO_Small-Device" 10 -60 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + SolderJumper*Open* +$ENDFPLIST +DRAW +C -40 0 20 0 1 0 N +C 40 0 20 0 1 0 N +X 1 1 -100 0 40 R 50 50 0 1 P +X 2 2 100 0 40 L 50 50 0 1 P +ENDDRAW +ENDDEF +# +# LED-Lily58-cache +# +DEF LED-Lily58-cache J 0 40 Y N 1 F N +F0 "J" 0 200 50 H V C CNN +F1 "LED-Lily58-cache" 0 -200 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + Connector*:*_??x*mm* + Connector*:*1x??x*mm* + Pin?Header?Straight?1X* + Pin?Header?Angled?1X* + Socket?Strip?Straight?1X* + Socket?Strip?Angled?1X* +$ENDFPLIST +DRAW +S -50 150 50 -150 1 1 10 f +S 0 -95 50 -105 1 1 6 N +S 0 5 50 -5 1 1 6 N +S 0 105 50 95 1 1 6 N +P 2 1 1 10 -50 -50 50 -50 N +P 2 1 1 10 -50 50 50 50 N +X Pin_1 1 200 100 150 L 50 50 1 1 P +X Pin_2 2 200 0 150 L 50 50 1 1 P +X Pin_3 3 200 -100 150 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# LED-Lily58-cache-Lily58_Pro-rescue +# +DEF LED-Lily58-cache-Lily58_Pro-rescue J 0 40 Y N 1 F N +F0 "J" 0 200 50 H V C CNN +F1 "LED-Lily58-cache-Lily58_Pro-rescue" 0 -200 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + Connector*:*_??x*mm* + Connector*:*1x??x*mm* + Pin?Header?Straight?1X* + Pin?Header?Angled?1X* + Socket?Strip?Straight?1X* + Socket?Strip?Angled?1X* +$ENDFPLIST +DRAW +S -50 150 50 -150 1 1 10 f +S 0 -95 50 -105 1 1 6 N +S 0 5 50 -5 1 1 6 N +S 0 105 50 95 1 1 6 N +P 2 1 1 10 -50 -50 50 -50 N +P 2 1 1 10 -50 50 50 50 N +X Pin_1 1 200 100 150 L 50 50 1 1 P +X Pin_2 2 200 0 150 L 50 50 1 1 P +X Pin_3 3 200 -100 150 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# MJ-4PP-9-Lily58-cache +# +DEF MJ-4PP-9-Lily58-cache J 0 40 Y Y 1 F N +F0 "J" -350 -300 60 H V C CNN +F1 "MJ-4PP-9-Lily58-cache" -150 250 60 H V C CNN +F2 "" 0 0 60 H V C CNN +F3 "" 0 0 60 H V C CNN +DRAW +S -300 100 -350 -150 0 1 0 N +S 300 -250 -400 200 0 1 0 N +P 2 0 1 0 100 0 300 0 N +P 3 0 1 0 -100 -200 300 -200 300 -200 N +P 3 0 1 0 0 -100 -50 -50 -100 -100 N +P 3 0 1 0 0 0 50 50 100 0 N +P 3 0 1 0 300 150 -300 150 -300 100 N +P 4 0 1 0 -100 -200 -150 -150 -200 -200 -200 -200 N +P 4 0 1 0 0 -100 300 -100 300 -100 300 -100 N +X ~ 1 450 0 150 L 50 50 1 1 P +X ~ 2 450 -100 150 L 50 50 1 1 P +X ~ 3 450 -200 150 L 50 50 1 1 P +X ~ 4 450 150 150 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue +# +DEF MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue J 0 40 Y Y 1 F N +F0 "J" -350 -300 60 H V C CNN +F1 "MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue" -150 250 60 H V C CNN +F2 "" 0 0 60 H V C CNN +F3 "" 0 0 60 H V C CNN +DRAW +S -300 100 -350 -150 0 1 0 N +S 300 -250 -400 200 0 1 0 N +P 2 0 1 0 100 0 300 0 N +P 3 0 1 0 -100 -200 300 -200 300 -200 N +P 3 0 1 0 0 -100 -50 -50 -100 -100 N +P 3 0 1 0 0 0 50 50 100 0 N +P 3 0 1 0 300 150 -300 150 -300 100 N +P 4 0 1 0 -100 -200 -150 -150 -200 -200 -200 -200 N +P 4 0 1 0 0 -100 300 -100 300 -100 300 -100 N +X ~ 1 450 0 150 L 50 50 1 1 P +X ~ 2 450 -100 150 L 50 50 1 1 P +X ~ 3 450 -200 150 L 50 50 1 1 P +X ~ 4 450 150 150 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# OLED-Lily58-cache +# +DEF OLED-Lily58-cache J 0 40 Y N 1 F N +F0 "J" 0 250 50 H V C CNN +F1 "OLED-Lily58-cache" 100 0 50 V V C CNN +F2 "" 0 0 50 H V C CNN +F3 "" 0 0 50 H V C CNN +$FPLIST + Pin_Header_Straight_1X04 + Pin_Header_Angled_1X04 + Socket_Strip_Straight_1X04 + Socket_Strip_Angled_1X04 +$ENDFPLIST +DRAW +S -50 -145 10 -155 0 1 0 N +S -50 -45 10 -55 0 1 0 N +S -50 55 10 45 0 1 0 N +S -50 155 10 145 0 1 0 N +S -50 200 50 -200 0 1 0 N +X P1 1 -200 150 150 R 50 50 1 1 P +X P2 2 -200 50 150 R 50 50 1 1 P +X P3 3 -200 -50 150 R 50 50 1 1 P +X P4 4 -200 -150 150 R 50 50 1 1 P +ENDDRAW +ENDDEF +# +# OLED-Lily58-cache-Lily58_Pro-rescue +# +DEF OLED-Lily58-cache-Lily58_Pro-rescue J 0 40 Y N 1 F N +F0 "J" 0 250 50 H V C CNN +F1 "OLED-Lily58-cache-Lily58_Pro-rescue" 100 0 50 V V C CNN +F2 "" 0 0 50 H V C CNN +F3 "" 0 0 50 H V C CNN +$FPLIST + Pin_Header_Straight_1X04 + Pin_Header_Angled_1X04 + Socket_Strip_Straight_1X04 + Socket_Strip_Angled_1X04 +$ENDFPLIST +DRAW +S -50 -145 10 -155 0 1 0 N +S -50 -45 10 -55 0 1 0 N +S -50 55 10 45 0 1 0 N +S -50 155 10 145 0 1 0 N +S -50 200 50 -200 0 1 0 N +X P1 1 -200 150 150 R 50 50 1 1 P +X P2 2 -200 50 150 R 50 50 1 1 P +X P3 3 -200 -50 150 R 50 50 1 1 P +X P4 4 -200 -150 150 R 50 50 1 1 P +ENDDRAW +ENDDEF +# +# PWR_FLAG-Lily58-cache +# +DEF PWR_FLAG-Lily58-cache #FLG 0 0 N N 1 F P +F0 "#FLG" 0 0 50 H I C CNN +F1 "PWR_FLAG-Lily58-cache" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 0 1 0 0 0 0 50 -40 75 0 100 40 75 0 50 N +X pwr 1 0 0 0 U 50 50 0 0 w +ENDDRAW +ENDDEF +# +# PWR_FLAG-Lily58-cache-Lily58_Pro-rescue +# +DEF PWR_FLAG-Lily58-cache-Lily58_Pro-rescue #FLG 0 0 N N 1 F P +F0 "#FLG" 0 0 50 H I C CNN +F1 "PWR_FLAG-Lily58-cache-Lily58_Pro-rescue" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 6 0 1 0 0 0 0 50 -40 75 0 100 40 75 0 50 N +X pwr 1 0 0 0 U 50 50 0 0 w +ENDDRAW +ENDDEF +# +# ProMicro_2-Lily58-cache +# +DEF ProMicro_2-Lily58-cache U 0 40 Y Y 1 F N +F0 "U" 0 700 50 H V C CNN +F1 "ProMicro_2-Lily58-cache" 0 -700 50 H V C CNN +F2 "" -50 100 50 H I C CNN +F3 "" -50 100 50 H I C CNN +DRAW +S -450 650 450 -650 0 1 0 N +X TX(PD3) 1 -650 550 200 R 50 50 1 1 I +X D7(PE6) 10 -650 -350 200 R 50 50 1 1 I +X D8(PB4) 11 -650 -450 200 R 50 50 1 1 I +X D9(PB5) 12 -650 -550 200 R 50 50 1 1 I +X D10(PB6) 13 650 -550 200 L 50 50 1 1 I +X D16(PB2) 14 650 -450 200 L 50 50 1 1 I +X D14(PB3) 15 650 -350 200 L 50 50 1 1 I +X D15(PB1) 16 650 -250 200 L 50 50 1 1 I +X A0(PF7) 17 650 -150 200 L 50 50 1 1 I +X A1(PF6) 18 650 -50 200 L 50 50 1 1 I +X A2(PF5) 19 650 50 200 L 50 50 1 1 I +X RX(PD2) 2 -650 450 200 R 50 50 1 1 I +X A3(PF4) 20 650 150 200 L 50 50 1 1 I +X VCC 21 650 250 200 L 50 50 1 1 I +X RST 22 650 350 200 L 50 50 1 1 I +X GND 23 650 450 200 L 50 50 1 1 I +X RAW 24 650 550 200 L 50 50 1 1 I +X GND 3 -650 350 200 R 50 50 1 1 I +X GND 4 -650 250 200 R 50 50 1 1 I +X SDA(PD1) 5 -650 150 200 R 50 50 1 1 I +X SCL(PD0) 6 -650 50 200 R 50 50 1 1 I +X D4(PD4) 7 -650 -50 200 R 50 50 1 1 I +X D5(PC6) 8 -650 -150 200 R 50 50 1 1 I +X D6(PD7) 9 -650 -250 200 R 50 50 1 1 I +ENDDRAW +ENDDEF +# +# ProMicro_2-Lily58-cache-Lily58_Pro-rescue +# +DEF ProMicro_2-Lily58-cache-Lily58_Pro-rescue U 0 40 Y Y 1 F N +F0 "U" 0 700 50 H V C CNN +F1 "ProMicro_2-Lily58-cache-Lily58_Pro-rescue" 0 -700 50 H V C CNN +F2 "" -50 100 50 H I C CNN +F3 "" -50 100 50 H I C CNN +DRAW +S -450 650 450 -650 0 1 0 N +X TX(PD3) 1 -650 550 200 R 50 50 1 1 I +X D7(PE6) 10 -650 -350 200 R 50 50 1 1 I +X D8(PB4) 11 -650 -450 200 R 50 50 1 1 I +X D9(PB5) 12 -650 -550 200 R 50 50 1 1 I +X D10(PB6) 13 650 -550 200 L 50 50 1 1 I +X D16(PB2) 14 650 -450 200 L 50 50 1 1 I +X D14(PB3) 15 650 -350 200 L 50 50 1 1 I +X D15(PB1) 16 650 -250 200 L 50 50 1 1 I +X A0(PF7) 17 650 -150 200 L 50 50 1 1 I +X A1(PF6) 18 650 -50 200 L 50 50 1 1 I +X A2(PF5) 19 650 50 200 L 50 50 1 1 I +X RX(PD2) 2 -650 450 200 R 50 50 1 1 I +X A3(PF4) 20 650 150 200 L 50 50 1 1 I +X VCC 21 650 250 200 L 50 50 1 1 I +X RST 22 650 350 200 L 50 50 1 1 I +X GND 23 650 450 200 L 50 50 1 1 I +X RAW 24 650 550 200 L 50 50 1 1 I +X GND 3 -650 350 200 R 50 50 1 1 I +X GND 4 -650 250 200 R 50 50 1 1 I +X SDA(PD1) 5 -650 150 200 R 50 50 1 1 I +X SCL(PD0) 6 -650 50 200 R 50 50 1 1 I +X D4(PD4) 7 -650 -50 200 R 50 50 1 1 I +X D5(PC6) 8 -650 -150 200 R 50 50 1 1 I +X D6(PD7) 9 -650 -250 200 R 50 50 1 1 I +ENDDRAW +ENDDEF +# +# R-Lily58-cache +# +DEF R-Lily58-cache R 0 0 N Y 1 F N +F0 "R" 0 0 50 V V C CNN +F1 "R-Lily58-cache" -100 0 50 V V C CNN +F2 "" -70 0 50 V I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + R_* +$ENDFPLIST +DRAW +S -40 -100 40 100 0 1 10 N +X ~ 1 0 150 50 D 50 50 1 1 P +X ~ 2 0 -150 50 U 50 50 1 1 P +ENDDRAW +ENDDEF +# +# R-Lily58-cache-Lily58_Pro-rescue +# +DEF R-Lily58-cache-Lily58_Pro-rescue R 0 0 N Y 1 F N +F0 "R" 0 0 50 V V C CNN +F1 "R-Lily58-cache-Lily58_Pro-rescue" -100 0 50 V V C CNN +F2 "" -70 0 50 V I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + R_* +$ENDFPLIST +DRAW +S -40 -100 40 100 0 1 10 N +X ~ 1 0 150 50 D 50 50 1 1 P +X ~ 2 0 -150 50 U 50 50 1 1 P +ENDDRAW +ENDDEF +# +# Rotary_Encoder_Switch-Device +# +DEF Rotary_Encoder_Switch-Device SW 0 10 Y N 1 F N +F0 "SW" 0 260 50 H V C CNN +F1 "Rotary_Encoder_Switch-Device" 0 -260 50 H V C CNN +F2 "" -150 160 50 H I C CNN +F3 "" 0 260 50 H I C CNN +$FPLIST + RotaryEncoder*Switch* +$ENDFPLIST +DRAW +A -15 -2 108 -899 899 0 1 10 N -15 -110 -15 105 +C -150 0 10 0 1 0 F +C -15 0 75 0 1 10 N +C 170 -40 5 0 1 10 N +C 170 40 5 0 1 10 N +S -200 200 200 -200 0 1 10 f +P 2 0 1 10 -25 -70 -25 70 N +P 2 0 1 10 -15 -70 -15 70 N +P 2 0 1 10 -5 70 -5 -70 N +P 2 0 1 10 150 0 135 0 N +P 2 0 1 10 150 40 150 -40 N +P 3 0 1 0 -200 -100 -150 -100 -150 -80 N +P 3 0 1 0 -200 100 -150 100 -150 80 N +P 3 0 1 10 10 -120 -20 -110 5 -95 N +P 3 0 1 10 10 115 -20 105 5 90 N +P 3 0 1 10 200 -100 170 -100 170 -40 N +P 3 0 1 10 200 100 170 100 170 40 N +P 4 0 1 0 -200 0 -150 0 -150 -40 -130 -80 N +P 4 0 1 0 -170 0 -150 0 -150 40 -130 80 N +X A A -300 100 100 R 50 50 1 1 P +X B B -300 -100 100 R 50 50 1 1 P +X C C -300 0 100 R 50 50 1 1 P +X S1 S1 300 100 100 L 50 50 1 1 P +X S2 S2 300 -100 100 L 50 50 1 1 P +ENDDRAW +ENDDEF +# +# SW_PUSH-Lily58-cache +# +DEF SW_PUSH-Lily58-cache SW 0 40 N N 1 F N +F0 "SW" 150 110 50 H V C CNN +F1 "SW_PUSH-Lily58-cache" 0 -80 50 H V C CNN +F2 "" 0 0 50 H V C CNN +F3 "" 0 0 50 H V C CNN +DRAW +S -170 50 170 60 0 1 0 N +P 4 0 1 0 -40 60 -30 90 30 90 40 60 N +X 1 1 -300 0 200 R 50 50 0 1 P I +X 2 2 300 0 200 L 50 50 0 1 P I +ENDDRAW +ENDDEF +# +# SW_PUSH-Lily58-cache-Lily58_Pro-rescue +# +DEF SW_PUSH-Lily58-cache-Lily58_Pro-rescue SW 0 40 N N 1 F N +F0 "SW" 150 110 50 H V C CNN +F1 "SW_PUSH-Lily58-cache-Lily58_Pro-rescue" 0 -80 50 H V C CNN +F2 "" 0 0 50 H V C CNN +F3 "" 0 0 50 H V C CNN +DRAW +S -170 50 170 60 0 1 0 N +P 4 0 1 0 -40 60 -30 90 30 90 40 60 N +X 1 1 -300 0 200 R 50 50 0 1 P I +X 2 2 300 0 200 L 50 50 0 1 P I +ENDDRAW +ENDDEF +# +# SW_PUSH-Lily58-cache-Lily58_Pro-withLED +# +DEF SW_PUSH-Lily58-cache-Lily58_Pro-withLED SW 0 40 N N 1 F N +F0 "SW" 150 110 50 H V C CNN +F1 "SW_PUSH-Lily58-cache-Lily58_Pro-withLED" 0 -80 50 H V C CNN +F2 "" 0 0 50 H V C CNN +F3 "" 0 0 50 H V C CNN +DRAW +T 0 -50 -300 50 0 0 0 "sk6012 mini" Normal 0 C C +S -170 50 170 60 0 1 0 N +P 4 0 1 0 -40 60 -30 90 30 90 40 60 N +X 1 1 -300 0 200 R 50 50 0 1 P I +X 2 2 300 0 200 L 50 50 0 1 P I +X DOUT 1B -300 -350 100 R 50 50 1 1 O +X VSS 2B -300 -500 100 R 50 50 1 1 W +X DIN 3B 250 -500 100 L 50 50 1 1 I +X VDD 4B 250 -350 100 L 50 50 1 1 W +ENDDRAW +ENDDEF +# +# SW_RST-Lily58-cache +# +DEF SW_RST-Lily58-cache RSW 0 40 N N 1 F N +F0 "RSW" 100 100 40 H V C CNN +F1 "SW_RST-Lily58-cache" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 2 0 1 0 -100 50 100 50 N +P 2 0 1 0 0 100 0 50 N +X 1 1 -150 0 100 R 50 50 0 1 P I +X 2 2 150 0 100 L 50 50 0 1 P I +ENDDRAW +ENDDEF +# +# SW_RST-Lily58-cache-Lily58_Pro-rescue +# +DEF SW_RST-Lily58-cache-Lily58_Pro-rescue RSW 0 40 N N 1 F N +F0 "RSW" 100 100 40 H V C CNN +F1 "SW_RST-Lily58-cache-Lily58_Pro-rescue" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +P 2 0 1 0 -100 50 100 50 N +P 2 0 1 0 0 100 0 50 N +X 1 1 -150 0 100 R 50 50 0 1 P I +X 2 2 150 0 100 L 50 50 0 1 P I +ENDDRAW +ENDDEF +# +# VCC-Lily58-cache +# +DEF VCC-Lily58-cache #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -150 50 H I C CNN +F1 "VCC-Lily58-cache" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +C 0 75 25 0 1 0 N +P 2 0 1 0 0 0 0 50 N +X VCC 1 0 0 0 U 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# VCC-Lily58-cache-Lily58_Pro-rescue +# +DEF VCC-Lily58-cache-Lily58_Pro-rescue #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -150 50 H I C CNN +F1 "VCC-Lily58-cache-Lily58_Pro-rescue" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +C 0 75 25 0 1 0 N +P 2 0 1 0 0 0 0 50 N +X VCC 1 0 0 0 U 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# VCC-power +# +DEF VCC-power #PWR 0 0 Y Y 1 F P +F0 "#PWR" 0 -150 50 H I C CNN +F1 "VCC-power" 0 150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +C 0 75 25 0 1 0 N +P 2 0 1 0 0 0 0 50 N +X VCC 1 0 0 0 U 50 50 1 1 W N +ENDDRAW +ENDDEF +# +# i2c_pin-Lily58-cache +# +DEF i2c_pin-Lily58-cache J 0 40 Y N 1 F N +F0 "J" 0 100 50 H V C CNN +F1 "i2c_pin-Lily58-cache" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + Connector*:*_??x*mm* + Connector*:*1x??x*mm* + Pin?Header?Straight?1X* + Pin?Header?Angled?1X* + Socket?Strip?Straight?1X* + Socket?Strip?Angled?1X* +$ENDFPLIST +DRAW +S -50 5 0 -5 1 1 6 N +S -50 50 50 -50 1 1 10 f +X Pin_1 1 -200 0 150 R 50 50 1 1 P +ENDDRAW +ENDDEF +# +# i2c_pin-Lily58-cache-Lily58_Pro-rescue +# +DEF i2c_pin-Lily58-cache-Lily58_Pro-rescue J 0 40 Y N 1 F N +F0 "J" 0 100 50 H V C CNN +F1 "i2c_pin-Lily58-cache-Lily58_Pro-rescue" 0 -100 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +$FPLIST + Connector*:*_??x*mm* + Connector*:*1x??x*mm* + Pin?Header?Straight?1X* + Pin?Header?Angled?1X* + Socket?Strip?Straight?1X* + Socket?Strip?Angled?1X* +$ENDFPLIST +DRAW +S -50 5 0 -5 1 1 6 N +S -50 50 50 -50 1 1 10 f +X Pin_1 1 -200 0 150 R 50 50 1 1 P +ENDDRAW +ENDDEF +# +#End Library diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.dcm b/Sofle_RGB_v3/PCB/SofleKeyboard.dcm new file mode 100644 index 00000000..5f3ed79b --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.dcm @@ -0,0 +1,3 @@ +EESchema-DOCLIB Version 2.0 +# +#End Doc Library diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb new file mode 100644 index 00000000..cf46c6f4 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb @@ -0,0 +1,16436 @@ +(kicad_pcb (version 20171130) (host pcbnew "(5.1.12-1-10_14)") + + (general + (thickness 1.6) + (drawings 350) + (tracks 3564) + (zones 0) + (modules 96) + (nets 95) + ) + + (page A4) + (layers + (0 F.Cu signal) + (31 B.Cu signal) + (32 B.Adhes user hide) + (33 F.Adhes user hide) + (34 B.Paste user) + (35 F.Paste user) + (36 B.SilkS user) + (37 F.SilkS user) + (38 B.Mask user) + (39 F.Mask user) + (40 Dwgs.User user hide) + (41 Cmts.User user hide) + (42 Eco1.User user hide) + (43 Eco2.User user hide) + (44 Edge.Cuts user) + (45 Margin user hide) + (46 B.CrtYd user hide) + (47 F.CrtYd user hide) + (48 B.Fab user hide) + (49 F.Fab user hide) + ) + + (setup + (last_trace_width 0.25) + (user_trace_width 0.25) + (user_trace_width 0.5) + (trace_clearance 0.2) + (zone_clearance 0.5) + (zone_45_only no) + (trace_min 0.2) + (via_size 0.4) + (via_drill 0.3) + (via_min_size 0.4) + (via_min_drill 0.3) + (uvia_size 0.3) + (uvia_drill 0.1) + (uvias_allowed no) + (uvia_min_size 0.2) + (uvia_min_drill 0.1) + (edge_width 0.15) + (segment_width 0.2) + (pcb_text_width 0.3) + (pcb_text_size 1.5 1.5) + (mod_edge_width 0.15) + (mod_text_size 1 1) + (mod_text_width 0.15) + (pad_size 0.635 1.143) + (pad_drill 0) + (pad_to_mask_clearance 0.2) + (aux_axis_origin 0 0) + (visible_elements 7FFFF7FF) + (pcbplotparams + (layerselection 0x010f0_ffffffff) + (usegerberextensions true) + (usegerberattributes false) + (usegerberadvancedattributes false) + (creategerberjobfile false) + (excludeedgelayer true) + (linewidth 0.100000) + (plotframeref false) + (viasonmask false) + (mode 1) + (useauxorigin false) + (hpglpennumber 1) + (hpglpenspeed 20) + (hpglpendiameter 15.000000) + (psnegative false) + (psa4output false) + (plotreference true) + (plotvalue true) + (plotinvisibletext false) + (padsonsilk false) + (subtractmaskfromsilk false) + (outputformat 1) + (mirror false) + (drillshape 0) + (scaleselection 1) + (outputdirectory "gerber/")) + ) + + (net 0 "") + (net 1 "Net-(D1-Pad2)") + (net 2 row4) + (net 3 "Net-(D2-Pad2)") + (net 4 "Net-(D3-Pad2)") + (net 5 row0) + (net 6 "Net-(D4-Pad2)") + (net 7 row1) + (net 8 "Net-(D5-Pad2)") + (net 9 row2) + (net 10 "Net-(D6-Pad2)") + (net 11 row3) + (net 12 "Net-(D7-Pad2)") + (net 13 "Net-(D8-Pad2)") + (net 14 "Net-(D9-Pad2)") + (net 15 "Net-(D10-Pad2)") + (net 16 "Net-(D11-Pad2)") + (net 17 "Net-(D12-Pad2)") + (net 18 "Net-(D13-Pad2)") + (net 19 "Net-(D14-Pad2)") + (net 20 "Net-(D15-Pad2)") + (net 21 "Net-(D16-Pad2)") + (net 22 "Net-(D17-Pad2)") + (net 23 "Net-(D18-Pad2)") + (net 24 "Net-(D19-Pad2)") + (net 25 "Net-(D20-Pad2)") + (net 26 "Net-(D21-Pad2)") + (net 27 "Net-(D22-Pad2)") + (net 28 "Net-(D23-Pad2)") + (net 29 "Net-(D24-Pad2)") + (net 30 "Net-(D26-Pad2)") + (net 31 "Net-(D27-Pad2)") + (net 32 "Net-(D28-Pad2)") + (net 33 VCC) + (net 34 GND) + (net 35 col0) + (net 36 col1) + (net 37 col2) + (net 38 col3) + (net 39 col4) + (net 40 SDA) + (net 41 LED) + (net 42 SCL) + (net 43 RESET) + (net 44 "Net-(D29-Pad2)") + (net 45 "Net-(U1-Pad24)") + (net 46 "Net-(U1-Pad7)") + (net 47 DATA) + (net 48 "Net-(J3-Pad1)") + (net 49 "Net-(J3-Pad2)") + (net 50 "Net-(J3-Pad3)") + (net 51 "Net-(J3-Pad4)") + (net 52 "Net-(D30-Pad2)") + (net 53 SW25B) + (net 54 SW25A) + (net 55 ENCB) + (net 56 ENCA) + (net 57 /i2c_c) + (net 58 /i2c_d) + (net 59 "Net-(D31-Pad1)") + (net 60 "Net-(D31-Pad3)") + (net 61 "Net-(D32-Pad3)") + (net 62 "Net-(D34-Pad1)") + (net 63 "Net-(D35-Pad1)") + (net 64 lights) + (net 65 "Net-(SW1-Pad3)") + (net 66 "Net-(SW1-Pad1)") + (net 67 "Net-(SW2-Pad3)") + (net 68 "Net-(SW3-Pad3)") + (net 69 "Net-(SW3-Pad1)") + (net 70 "Net-(SW10-Pad1)") + (net 71 "Net-(SW5-Pad3)") + (net 72 "Net-(SW11-Pad3)") + (net 73 "Net-(SW12-Pad1)") + (net 74 "Net-(SW13-Pad3)") + (net 75 "Net-(SW14-Pad1)") + (net 76 "Net-(SW15-Pad3)") + (net 77 "Net-(SW10-Pad3)") + (net 78 "Net-(SW11-Pad1)") + (net 79 "Net-(SW12-Pad3)") + (net 80 "Net-(SW13-Pad1)") + (net 81 "Net-(SW14-Pad3)") + (net 82 "Net-(SW15-Pad1)") + (net 83 "Net-(SW16-Pad3)") + (net 84 "Net-(SW17-Pad1)") + (net 85 "Net-(SW18-Pad3)") + (net 86 "Net-(SW19-Pad1)") + (net 87 "Net-(SW20-Pad3)") + (net 88 "Net-(SW21-Pad1)") + (net 89 "Net-(SW22-Pad3)") + (net 90 "Net-(SW23-Pad1)") + (net 91 "Net-(SW24-Pad3)") + (net 92 "Net-(SW26-Pad3)") + (net 93 "Net-(SW28-Pad3)") + (net 94 BL) + + (net_class Default "これは標準のネット クラスです。" + (clearance 0.2) + (trace_width 0.25) + (via_dia 0.4) + (via_drill 0.3) + (uvia_dia 0.3) + (uvia_drill 0.1) + (add_net /i2c_c) + (add_net /i2c_d) + (add_net BL) + (add_net DATA) + (add_net ENCA) + (add_net ENCB) + (add_net LED) + (add_net "Net-(D1-Pad2)") + (add_net "Net-(D10-Pad2)") + (add_net "Net-(D11-Pad2)") + (add_net "Net-(D12-Pad2)") + (add_net "Net-(D13-Pad2)") + (add_net "Net-(D14-Pad2)") + (add_net "Net-(D15-Pad2)") + (add_net "Net-(D16-Pad2)") + (add_net "Net-(D17-Pad2)") + (add_net "Net-(D18-Pad2)") + (add_net "Net-(D19-Pad2)") + (add_net "Net-(D2-Pad2)") + (add_net "Net-(D20-Pad2)") + (add_net "Net-(D21-Pad2)") + (add_net "Net-(D22-Pad2)") + (add_net "Net-(D23-Pad2)") + (add_net "Net-(D24-Pad2)") + (add_net "Net-(D26-Pad2)") + (add_net "Net-(D27-Pad2)") + (add_net "Net-(D28-Pad2)") + (add_net "Net-(D29-Pad2)") + (add_net "Net-(D3-Pad2)") + (add_net "Net-(D30-Pad2)") + (add_net "Net-(D31-Pad1)") + (add_net "Net-(D31-Pad3)") + (add_net "Net-(D32-Pad3)") + (add_net "Net-(D34-Pad1)") + (add_net "Net-(D35-Pad1)") + (add_net "Net-(D4-Pad2)") + (add_net "Net-(D5-Pad2)") + (add_net "Net-(D6-Pad2)") + (add_net "Net-(D7-Pad2)") + (add_net "Net-(D8-Pad2)") + (add_net "Net-(D9-Pad2)") + (add_net "Net-(J3-Pad1)") + (add_net "Net-(J3-Pad2)") + (add_net "Net-(J3-Pad3)") + (add_net "Net-(J3-Pad4)") + (add_net "Net-(SW1-Pad1)") + (add_net "Net-(SW1-Pad3)") + (add_net "Net-(SW10-Pad1)") + (add_net "Net-(SW10-Pad3)") + (add_net "Net-(SW11-Pad1)") + (add_net "Net-(SW11-Pad3)") + (add_net "Net-(SW12-Pad1)") + (add_net "Net-(SW12-Pad3)") + (add_net "Net-(SW13-Pad1)") + (add_net "Net-(SW13-Pad3)") + (add_net "Net-(SW14-Pad1)") + (add_net "Net-(SW14-Pad3)") + (add_net "Net-(SW15-Pad1)") + (add_net "Net-(SW15-Pad3)") + (add_net "Net-(SW16-Pad3)") + (add_net "Net-(SW17-Pad1)") + (add_net "Net-(SW18-Pad3)") + (add_net "Net-(SW19-Pad1)") + (add_net "Net-(SW2-Pad3)") + (add_net "Net-(SW20-Pad3)") + (add_net "Net-(SW21-Pad1)") + (add_net "Net-(SW22-Pad3)") + (add_net "Net-(SW23-Pad1)") + (add_net "Net-(SW24-Pad3)") + (add_net "Net-(SW26-Pad3)") + (add_net "Net-(SW28-Pad3)") + (add_net "Net-(SW3-Pad1)") + (add_net "Net-(SW3-Pad3)") + (add_net "Net-(SW5-Pad3)") + (add_net "Net-(U1-Pad24)") + (add_net "Net-(U1-Pad7)") + (add_net RESET) + (add_net SCL) + (add_net SDA) + (add_net SW25A) + (add_net SW25B) + (add_net col0) + (add_net col1) + (add_net col2) + (add_net col3) + (add_net col4) + (add_net lights) + (add_net row0) + (add_net row1) + (add_net row2) + (add_net row3) + (add_net row4) + ) + + (net_class GND "" + (clearance 0.2) + (trace_width 0.5) + (via_dia 0.4) + (via_drill 0.3) + (uvia_dia 0.3) + (uvia_drill 0.1) + (add_net GND) + ) + + (net_class VCC "" + (clearance 0.2) + (trace_width 0.5) + (via_dia 0.4) + (via_drill 0.3) + (uvia_dia 0.3) + (uvia_drill 0.1) + (add_net VCC) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9724D) + (at 128.75 45.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7226E7) + (autoplace_cost180 10) + (fp_text reference D1 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 1 "Net-(D1-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 1 "Net-(D1-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9725A) + (at 131 45.7805 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722847) + (autoplace_cost180 10) + (fp_text reference D2 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 3 "Net-(D2-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 3 "Net-(D2-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97267) + (at 150.5 43.04 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722950) + (autoplace_cost180 10) + (fp_text reference D3 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 4 "Net-(D3-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 4 "Net-(D3-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97274) + (at 169.25 45.425 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722A8F) + (autoplace_cost180 10) + (fp_text reference D4 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 6 "Net-(D4-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 6 "Net-(D4-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97281) + (at 188 50.25 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722BAD) + (autoplace_cost180 10) + (fp_text reference D5 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 8 "Net-(D5-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 8 "Net-(D5-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9728E) + (at 207.75 50.025 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722FE1) + (autoplace_cost180 10) + (fp_text reference D6 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 10 "Net-(D6-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 10 "Net-(D6-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9729B) + (at 126.8 63.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723D94) + (autoplace_cost180 10) + (fp_text reference D7 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972A8) + (at 129.8 63.8 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723E5F) + (autoplace_cost180 10) + (fp_text reference D8 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 13 "Net-(D8-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 13 "Net-(D8-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972B5) + (at 150.25 61.065 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723FA1) + (autoplace_cost180 10) + (fp_text reference D9 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 14 "Net-(D9-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 14 "Net-(D9-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972C2) + (at 169.5 63.65 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7240EA) + (autoplace_cost180 10) + (fp_text reference D10 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 15 "Net-(D10-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 15 "Net-(D10-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972CF) + (at 188.25 66.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72424D) + (autoplace_cost180 10) + (fp_text reference D11 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 16 "Net-(D11-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 16 "Net-(D11-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972DC) + (at 207.75 67.275 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7243C0) + (autoplace_cost180 10) + (fp_text reference D12 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 17 "Net-(D12-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 17 "Net-(D12-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972E9) + (at 128.5 83.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7254EE) + (autoplace_cost180 10) + (fp_text reference D13 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972F6) + (at 131.25 83.675 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7255FF) + (autoplace_cost180 10) + (fp_text reference D14 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 19 "Net-(D14-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 19 "Net-(D14-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97303) + (at 149.75 81.565 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72571C) + (autoplace_cost180 10) + (fp_text reference D15 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 20 "Net-(D15-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 20 "Net-(D15-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97310) + (at 169.725 83.425 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B725841) + (autoplace_cost180 10) + (fp_text reference D16 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 21 "Net-(D16-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 21 "Net-(D16-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9731D) + (at 188.5 88.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72596D) + (autoplace_cost180 10) + (fp_text reference D17 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 22 "Net-(D17-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 22 "Net-(D17-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9732A) + (at 207.75 86.275 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B725AA2) + (autoplace_cost180 10) + (fp_text reference D18 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 23 "Net-(D18-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 23 "Net-(D18-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97337) + (at 112 102.75 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72767A) + (autoplace_cost180 10) + (fp_text reference D19 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97344) + (at 131 103.175 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7277CE) + (autoplace_cost180 10) + (fp_text reference D20 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 25 "Net-(D20-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 25 "Net-(D20-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97351) + (at 150 98.565 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727929) + (autoplace_cost180 10) + (fp_text reference D21 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 26 "Net-(D21-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 26 "Net-(D21-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9735E) + (at 169.25 102.15 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727A89) + (autoplace_cost180 10) + (fp_text reference D22 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 27 "Net-(D22-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 27 "Net-(D22-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9736B) + (at 188.5 106.75 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727BFE) + (autoplace_cost180 10) + (fp_text reference D23 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 28 "Net-(D23-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 28 "Net-(D23-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97378) + (at 208.2 105.175 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727D79) + (autoplace_cost180 10) + (fp_text reference D24 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 29 "Net-(D24-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 29 "Net-(D24-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97385) + (at 107 97) + (descr "Resitance 3 pas") + (tags R) + (path /5B734844) + (autoplace_cost180 10) + (fp_text reference D25 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 53 SW25B)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 53 SW25B)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F7EDC95) (tstamp 5BE97392) + (at 100.8 123.6) + (descr "Resitance 3 pas") + (tags R) + (path /5B7349D1) + (autoplace_cost180 10) + (fp_text reference D26 (at 0.7222 -1.1752) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 30 "Net-(D26-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 30 "Net-(D26-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9739F) + (at 110.4248 120.6248) + (descr "Resitance 3 pas") + (tags R) + (path /5B734B62) + (autoplace_cost180 10) + (fp_text reference D27 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 31 "Net-(D27-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 31 "Net-(D27-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973AC) + (at 125.775 124.2) + (descr "Resitance 3 pas") + (tags R) + (path /5B734CF9) + (autoplace_cost180 10) + (fp_text reference D28 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973B9) + (at 125.775 121.6) + (descr "Resitance 3 pas") + (tags R) + (path /5B734F9E) + (autoplace_cost180 10) + (fp_text reference D29 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5D8B2928) + (at 125.805 119.02) + (descr "Resitance 3 pas") + (tags R) + (path /5D956FE1) + (autoplace_cost180 10) + (fp_text reference D30 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5FDCA436) (tstamp 5BEDDC08) + (at 107.9 81.1 180) + (path /5B74AE32) + (fp_text reference J1 (at 0 6.9 180) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED (at 0 7.62 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_text user GND (at -2.1836 5.0524 180) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user LED (at -2.2 2.5 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user GND (at -2.1836 5.0524 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user VCC (at -2.2 0.1 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user J1 (at 0 6.9 180) (layer B.SilkS) + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole rect (at 0 0 270) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 33 VCC)) + (pad 2 thru_hole rect (at 0 2.5 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 41 LED)) + (pad 3 thru_hole rect (at 0 5.1 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 34 GND)) + ) + + (module SofleKeyboard-footprint:MJ-4PP-9 (layer F.Cu) (tedit 5D8BAE3B) (tstamp 5B8BE8A5) + (at 88 85.65 90) + (path /5B742D8C) + (fp_text reference J2 (at -0.889 6.4135 90) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value 4PIN (at 0 14 90) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) + (pad 4 thru_hole oval (at -2.1 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c) (clearance 0.15)) + (pad 1 thru_hole oval (at 2.1 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC) (clearance 0.15)) + (pad 2 thru_hole oval (at 2.1 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 3 thru_hole oval (at 2.1 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (pad "" np_thru_hole circle (at 0 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at 0 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad 2 thru_hole oval (at -3.85 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 3 thru_hole oval (at -3.85 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (pad 4 thru_hole oval (at 0.35 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c) (clearance 0.15)) + (pad 1 thru_hole oval (at -3.85 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC) (clearance 0.15)) + (pad "" np_thru_hole circle (at -1.75 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at -1.75 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (model "../../../../../../Users/pluis/Documents/Magic Briefcase/Documents/KiCad/3d/AB2_TRS_3p5MM_PTH.wrl" + (at (xyz 0 0 0)) + (scale (xyz 0.42 0.42 0.42)) + (rotate (xyz 0 0 90)) + ) + ) + + (module SofleKeyboard-footprint:OLED_4Pin (layer F.Cu) (tedit 59FC8837) (tstamp 5BEDDC3B) + (at 96.7 74.6) + (descr "Connecteur 6 pins") + (tags "CONN DEV") + (path /5B91007B) + (fp_text reference J3 (at -1.915 1.93 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value OLED (at 3.81 1.27) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer B.SilkS) (width 0.15)) + (pad 4 thru_hole circle (at 7.62 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 51 "Net-(J3-Pad4)")) + (pad 3 thru_hole circle (at 5.08 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 50 "Net-(J3-Pad3)")) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 49 "Net-(J3-Pad2)")) + (pad 1 thru_hole circle (at 0 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 48 "Net-(J3-Pad1)")) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95811) + (at 104.3 69.3 90) + (path /5B911E74) + (attr smd) + (fp_text reference JP1 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 34 GND) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE9581B) + (at 101.7 69.3 90) + (path /5B9120CE) + (attr smd) + (fp_text reference JP2 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 33 VCC) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95825) + (at 99.2 69.3 90) + (path /5B913646) + (attr smd) + (fp_text reference JP3 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 42 SCL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE98C76) + (at 96.7 69.3 90) + (path /5B913C11) + (attr smd) + (fp_text reference JP4 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 40 SDA) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE98BB2) + (at 104.3 69.3 90) + (path /5B9141F4) + (attr smd) + (fp_text reference JP5 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 40 SDA) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95843) + (at 101.7 69.3 90) + (path /5B9141FA) + (attr smd) + (fp_text reference JP6 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 42 SCL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE9584D) + (at 99.2 69.3 90) + (path /5B914200) + (attr smd) + (fp_text reference JP7 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 33 VCC) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95857) + (at 96.7 69.3 90) + (path /5B914206) + (attr smd) + (fp_text reference JP8 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 34 GND) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FD12) (tstamp 61CC20B4) + (at 185.4454 99.3394 270) + (path /620925F6) + (attr smd) + (fp_text reference JP10 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 64 lights) (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 94 BL) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FB9E) (tstamp 61CA7193) + (at 112.522 82.804 90) + (path /61D5D1D0) + (attr smd) + (fp_text reference JP9 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 41 LED) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 64 lights) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE931) + (at 102.7 80.3 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B8F6780) + (autoplace_cost180 10) + (fp_text reference P1 (at 0 -1.671944 270) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_text user P1 (at 0.2 -1.7 270) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE93F) + (at 102.7 78.1 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B8F6980) + (autoplace_cost180 10) + (fp_text reference P2 (at 0 -1.671944 270) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_text user P1 (at -0.1 1.7 270) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_text user P2 (at 0 -1.7 270) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B7351FC) + (at 98.039272 80.311965) + (descr "Resitance 3 pas") + (tags R) + (path /5B739F4A) + (autoplace_cost180 10) + (fp_text reference R1 (at -0.039272 -0.011965 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_text user R1 (at 0 -0.011965 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 40 SDA)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B735209) + (at 98.039272 78.061965) + (descr "Resitance 3 pas") + (tags R) + (path /5B73A034) + (autoplace_cost180 10) + (fp_text reference R2 (at -0.039272 0.038035 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_text user R2 (at 0 0 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 42 SCL)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:TACT_SWITCH_TVBP06 (layer F.Cu) (tedit 5B8CD44F) (tstamp 5BE9586C) + (at 90 77.5 270) + (path /5B8CE7E7) + (fp_text reference RSW1 (at 0 -1.7 90) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_RST (at 0 2 90) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 2.9 -1.8) (layer B.SilkS) (width 0.15)) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (pad 2 thru_hole circle (at 3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) + (net 43 RESET)) + (pad 1 thru_hole circle (at -3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) + (net 34 GND)) + ) + + (module SofleKeyboard-footprint:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified (layer F.Cu) (tedit 5D5C0C22) (tstamp 5D8CBBBB) + (at 100 104.5) + (descr "Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html") + (tags "rotary encoder") + (path /5DA04574) + (fp_text reference SW25 (at 4.24 4.6) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value Rotary_Encoder_Switch (at 0 7.9) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) + (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) + (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) + (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer B.SilkS) (width 0.12)) + (pad A thru_hole circle (at -7.5 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 56 ENCA)) + (pad C thru_hole circle (at -7.5 0) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 34 GND)) + (pad B thru_hole circle (at -7.5 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 55 ENCB)) + (pad MP thru_hole rect (at 0 -5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad MP thru_hole rect (at 0 5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad S2 thru_hole circle (at 7 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 53 SW25B)) + (pad S1 thru_hole circle (at 7 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 54 SW25A)) + (model ${KISYS3DMOD}/Rotary_Encoder.3dshapes/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 1 1 1)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5BE98A92) + (at 91.5 93.5) + (path /5B74CE27) + (fp_text reference TH1 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5D8BB010) + (at 107 93.5) + (path /5B74D0C7) + (fp_text reference TH2 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5B8BE94E) + (at 129.975 57.075) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805C11) (tstamp 5B8BE953) + (at 206.225 61.775) + (path /5B74D1C0) + (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BD0) (tstamp 5B8BE958) + (at 130.025 97.575) + (path /5B74D78B) + (fp_text reference TH5 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BFE) (tstamp 5B8BE95D) + (at 206.175 100.025) + (path /5B74D88C) + (fp_text reference TH6 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.175 -0.025 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F8059EF) (tstamp 5B8BE962) + (at 103 119 90) + (path /5B74D98F) + (fp_text reference TH7 (at 0 -2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0 0 180) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:ProMicro (layer F.Cu) (tedit 5B8BDEB4) (tstamp 5B8BE963) + (at 101 56) + (path /5B722440) + (fp_text reference U1 (at 0 1.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value ProMicro (at 0 -0.8) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -16.04) (layer B.SilkS) (width 0.15)) + (pad 22 thru_hole circle (at -7.521185 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 43 RESET)) + (pad 10 thru_hole circle (at 7.718815 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 9 row2)) + (pad 18 thru_hole circle (at -7.521185 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 35 col0)) + (pad 6 thru_hole circle (at 7.718815 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 42 SCL)) + (pad 4 thru_hole circle (at 7.718815 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 14 thru_hole circle (at -7.521185 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 39 col4)) + (pad 3 thru_hole circle (at 7.718815 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 1 thru_hole circle (at 7.718815 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 41 LED)) + (pad 16 thru_hole circle (at -7.521185 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 37 col2)) + (pad 12 thru_hole circle (at 7.718815 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 2 row4)) + (pad 19 thru_hole circle (at -7.521185 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 55 ENCB)) + (pad 23 thru_hole circle (at -7.521185 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 21 thru_hole circle (at -7.521185 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 33 VCC)) + (pad 20 thru_hole circle (at -7.521185 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 56 ENCA)) + (pad 15 thru_hole circle (at -7.521185 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 38 col3)) + (pad 17 thru_hole circle (at -7.521185 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 36 col1)) + (pad 9 thru_hole circle (at 7.718815 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 7 row1)) + (pad 8 thru_hole circle (at 7.718815 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 5 row0)) + (pad 13 thru_hole circle (at -7.521185 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 54 SW25A)) + (pad 11 thru_hole circle (at 7.718815 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 11 row3)) + (pad 2 thru_hole circle (at 7.718815 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 47 DATA)) + (pad 24 thru_hole circle (at -7.521185 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 45 "Net-(U1-Pad24)")) + (pad 7 thru_hole circle (at 7.718815 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 46 "Net-(U1-Pad7)")) + (pad 5 thru_hole circle (at 7.718815 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 40 SDA)) + (pad 1 thru_hole circle (at -8.82 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 41 LED)) + (pad 2 thru_hole circle (at -8.82 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 47 DATA)) + (pad 3 thru_hole circle (at -8.82 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 4 thru_hole circle (at -8.82 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 5 thru_hole circle (at -8.82 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 40 SDA)) + (pad 6 thru_hole circle (at -8.82 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 42 SCL)) + (pad 7 thru_hole circle (at -8.82 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 46 "Net-(U1-Pad7)")) + (pad 8 thru_hole circle (at -8.82 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 5 row0)) + (pad 9 thru_hole circle (at -8.82 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 7 row1)) + (pad 10 thru_hole circle (at -8.82 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 9 row2)) + (pad 11 thru_hole circle (at -8.82 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 11 row3)) + (pad 12 thru_hole circle (at -8.82 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 2 row4)) + (pad 13 thru_hole circle (at 6.42 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 54 SW25A)) + (pad 14 thru_hole circle (at 6.42 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 39 col4)) + (pad 15 thru_hole circle (at 6.42 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 38 col3)) + (pad 16 thru_hole circle (at 6.42 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 37 col2)) + (pad 17 thru_hole circle (at 6.42 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 36 col1)) + (pad 18 thru_hole circle (at 6.42 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 35 col0)) + (pad 19 thru_hole circle (at 6.42 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 55 ENCB)) + (pad 20 thru_hole circle (at 6.42 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 56 ENCA)) + (pad 21 thru_hole circle (at 6.42 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (pad 22 thru_hole circle (at 6.42 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 43 RESET)) + (pad 23 thru_hole circle (at 6.42 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 24 thru_hole circle (at 6.42 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 45 "Net-(U1-Pad24)")) + ) + + (module SofleKeyboard-footprint:jumper_data (layer F.Cu) (tedit 5D87BC97) (tstamp 5BE95B4C) + (at 94 75 270) + (path /5B900157) + (attr smd) + (fp_text reference W1 (at -1.8 0) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value jumper (at 0 1.524 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 47 DATA) (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 58 /i2c_d) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9E1) + (at 108.85 124.13) + (path /5F7EC8B3) + (fp_text reference D34 (at 0.95 -0.735) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C999) + (at 120.5 59.5 180) + (path /5F7E6561) + (fp_text reference D31 (at -4.94 -0.76) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9B1) + (at 158.5 53.79) + (path /5F7E9258) + (fp_text reference D32 (at -5.21 -1.04) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9C9) + (at 197.5 61.25 180) + (path /5F7EC8AD) + (fp_text reference D33 (at -4.84 1.41) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 64 lights)) + (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 64 lights)) + (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9F9) + (at 149.0836 118.2626) + (path /5F7EF5F2) + (fp_text reference D35 (at 0.88 -0.76) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA11) + (at 185.05 120.32) + (path /5F7EF5F8) + (fp_text reference D36 (at 0.87 -0.62) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA29) + (at 105.75 86.5) + (path /5F918D28) + (fp_text reference D37 (at 0 -2.5) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 41 LED)) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 64 lights)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 41 LED)) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 64 lights)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9874A) + (at 215.7 90.5 180) + (path /5F7D0195) + (fp_text reference SW18 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 23 "Net-(D18-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 23 "Net-(D18-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988EE) + (at 215.75 109.5 180) + (path /5F7D0171) + (fp_text reference SW24 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 29 "Net-(D24-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 29 "Net-(D24-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988A8) + (at 196.7 109.5 180) + (path /5F7D0177) + (fp_text reference SW23 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 180) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 28 "Net-(D23-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 28 "Net-(D23-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5FB24B70) + (at 215.8 52.4 180) + (path /5B722CA9) + (fp_text reference SW6 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 10 "Net-(D6-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 10 "Net-(D6-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9881C) + (at 158.6 102.19 180) + (path /5F7D0183) + (fp_text reference SW21 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 26 "Net-(D21-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 26 "Net-(D21-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985A6) + (at 215.7 71.3 180) + (path /5B723AD3) + (fp_text reference SW12 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 17 "Net-(D12-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 17 "Net-(D12-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98560) + (at 196.7 71.3 180) + (path /5B72387D) + (fp_text reference SW11 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 16 "Net-(D11-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 16 "Net-(D11-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98704) + (at 196.7 90.5 180) + (path /5F7D019B) + (fp_text reference SW17 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 22 "Net-(D17-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 22 "Net-(D17-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982EA) + (at 139.5 47.5 180) + (path /5F74DC46) + (fp_text reference SW2 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 3 "Net-(D2-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 3 "Net-(D2-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F7EF4F0) + (at 177.6 123.8 180) + (path /5F7D72C1) + (fp_text reference SW30 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A4C) + (at 158.6 121.29 180) + (path /5F7D72A9) + (fp_text reference SW29 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A06) + (at 139.5 123.7 180) + (path /5F7D72AF) + (fp_text reference SW28 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F806503) + (at 117.6 128.4 195) + (path /5F7D72B5) + (fp_text reference SW27 (at 0 3 15 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.199999 15) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 15) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 15) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 285) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 15) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 31 "Net-(D27-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 15) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 31 "Net-(D27-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9897A) + (at 96.71 133.4 120) + (path /5F7D72BB) + (fp_text reference SW26 (at 0 3 300 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 120) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 210) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 300) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 30 "Net-(D26-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 300) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 30 "Net-(D26-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98862) + (at 177.6 104.7 180) + (path /5F7D017D) + (fp_text reference SW22 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 27 "Net-(D22-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 27 "Net-(D22-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE987D6) + (at 139.5 104.7 180) + (path /5F7D0189) + (fp_text reference SW20 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 25 "Net-(D20-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 25 "Net-(D20-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98790) + (at 120.5 107.1 180) + (path /5F7D018F) + (fp_text reference SW19 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE986BE) + (at 177.6 85.6 180) + (path /5F7D01A1) + (fp_text reference SW16 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 21 "Net-(D16-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 21 "Net-(D16-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98678) + (at 158.6 83.19 180) + (path /5F7D01A7) + (fp_text reference SW15 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 20 "Net-(D15-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 20 "Net-(D15-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98632) + (at 139.5 85.6 180) + (path /5F7D01AD) + (fp_text reference SW14 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_text user SW15 (at 7.1 8.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 19 "Net-(D14-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 19 "Net-(D14-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985EC) + (at 120.5 88.1 180) + (path /5F7D01B3) + (fp_text reference SW13 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9851A) + (at 177.6 66.5 180) + (path /5B7237A6) + (fp_text reference SW10 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 15 "Net-(D10-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 15 "Net-(D10-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE984D4) + (at 158.6 64.09 180) + (path /5B723731) + (fp_text reference SW9 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 14 "Net-(D9-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 14 "Net-(D9-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9848E) + (at 139.5 66.6 180) + (path /5B723388) + (fp_text reference SW8 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 13 "Net-(D8-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 13 "Net-(D8-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98448) + (at 120.5 69.1 180) + (path /5B723C9D) + (fp_text reference SW7 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE983BC) + (at 196.7 52.4 180) + (path /5B722B51) + (fp_text reference SW5 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 8 "Net-(D5-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 8 "Net-(D5-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98376) + (at 177.6 47.5 180) + (path /5F74FBCC) + (fp_text reference SW4 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 6 "Net-(D4-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 6 "Net-(D4-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98330) + (at 158.6 45 180) + (path /5F74EA54) + (fp_text reference SW3 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 4 "Net-(D3-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 4 "Net-(D3-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982A4) + (at 120.5 50 180) + (path /5B7225DA) + (fp_text reference SW1 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 1 "Net-(D1-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 1 "Net-(D1-Pad2)")) + ) + + (module dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F8097A2) + (at 201 122.75 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) + (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) + (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) + (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) + (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) + (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) + (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) + (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) + (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) + (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) + (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) + (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) + (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) + (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) + (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) + (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) + (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) + (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) + (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) + (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) + (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) + (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) + (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) + (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) + (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) + (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) + (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) + (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) + (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) + (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) + (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) + (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) + (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) + (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) + (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) + (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) + (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) + (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) + (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) + (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) + (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) + (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) + (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) + (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) + (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) + (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) + (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) + (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) + (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) + (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) + (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) + (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) + (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) + (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) + (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) + (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) + (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) + (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) + (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) + (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) + (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) + (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) + (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) + (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) + (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) + (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) + (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) + (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) + (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) + (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) + (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) + (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) + (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) + (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) + (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) + (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) + (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) + (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) + (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) + (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) + (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) + (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) + (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) + (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) + (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) + (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) + (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) + (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) + (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) + (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) + (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) + (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) + (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) + (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) + (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) + (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) + (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) + (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) + (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) + (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) + (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) + (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) + (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) + (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) + (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) + (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) + (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) + (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) + (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) + (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) + (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) + (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) + (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) + (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) + (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) + (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) + (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) + (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) + (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) + (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) + (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) + (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) + (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) + (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) + (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) + (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) + (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) + (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) + (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) + (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) + (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) + (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) + (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) + (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) + (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) + (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) + (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) + (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) + (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) + (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) + (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) + (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) + (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) + (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) + (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) + (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) + (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) + (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) + (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) + (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) + (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) + (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) + ) + + (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F809028) + (at 200.25 122.75) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) + ) + + (gr_text "Sofle RGB by Dane Evans, original by Josef Adamacik" (at 113.75 39) (layer F.SilkS) (tstamp 5FDB143C) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_text s6 (at 215.5 47) (layer Eco1.User) (tstamp 5FB24AE6) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s5 (at 196.5 47) (layer Eco1.User) (tstamp 5FB24AE6) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s16 (at 177.5 80) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s15 (at 158.5 77.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s14 (at 139.5 80) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s12 (at 215.5 65.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s11 (at 196.5 65.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s10 (at 178 61) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s9 (at 158.5 58.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s8 (at 139.5 61) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s4 (at 177.5 42) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s3 (at 158.5 39.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s2 (at 139.5 41.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s1 (at 120.5 44.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s7 (at 120.5 63) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s13 (at 120.5 82.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s18 (at 215.5 85) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s17 (at 196.5 85) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s22 (at 177.5 99) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s21\n" (at 158.5 97) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s20\n" (at 139.5 99) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s19\n" (at 120.5 101.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s24 (at 215.5 104) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s23\n" (at 196.5 104) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s30\n" (at 177.5 118) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s29\n" (at 158.5 116) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s28\n" (at 139.5 118.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s27 (at 116 123.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s26\n" (at 96 133) (layer Eco1.User) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_circle (center 206 100) (end 208 100) (layer Eco2.User) (width 0.15) (tstamp 5F80A7FB)) + (gr_circle (center 103 119) (end 105 119) (layer Eco2.User) (width 0.15) (tstamp 5F80A7FB)) + (gr_circle (center 206 61.5) (end 208 61.5) (layer Eco2.User) (width 0.15) (tstamp 5F809B7A)) + (gr_circle (center 130 57) (end 132 57) (layer Eco2.User) (width 0.15)) + (gr_circle (center 130 97.5) (end 132 97.5) (layer Eco2.User) (width 0.15)) + (gr_line (start 179.3488 116.0352) (end 179.3488 120.5352) (layer Edge.Cuts) (width 0.15) (tstamp 5F80961C)) + (gr_line (start 179.35 97.05) (end 179.35 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F80961B)) + (gr_line (start 160.3504 113.5362) (end 160.3504 118.0362) (layer Edge.Cuts) (width 0.15) (tstamp 5F80961A)) + (gr_line (start 194.95 82.75) (end 198.45 82.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F809619)) + (gr_line (start 141.2504 120.4492) (end 137.7504 120.4492) (layer Edge.Cuts) (width 0.15) (tstamp 5F809618)) + (gr_line (start 160.35 98.9308) (end 156.85 98.9308) (layer Edge.Cuts) (width 0.15) (tstamp 5F809617)) + (gr_line (start 118.75 99.35) (end 122.25 99.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F809616)) + (gr_line (start 137.7504 115.9492) (end 141.2504 115.9492) (layer Edge.Cuts) (width 0.15) (tstamp 5F809615)) + (gr_line (start 156.85 75.4562) (end 160.35 75.4562) (layer Edge.Cuts) (width 0.15) (tstamp 5F809614)) + (gr_line (start 194.95 101.75) (end 198.45 101.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F809613)) + (gr_line (start 156.85 79.9562) (end 156.85 75.4562) (layer Edge.Cuts) (width 0.15) (tstamp 5F809612)) + (gr_line (start 137.7504 120.4492) (end 137.7504 115.9492) (layer Edge.Cuts) (width 0.15) (tstamp 5F809611)) + (gr_line (start 118.75 103.85) (end 118.75 99.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F809610)) + (gr_line (start 137.75 97.05) (end 141.25 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960F)) + (gr_line (start 175.85 97.05) (end 179.35 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960E)) + (gr_line (start 160.35 75.4562) (end 160.35 79.9562) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960D)) + (gr_line (start 179.3488 120.5352) (end 175.8488 120.5352) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960C)) + (gr_line (start 217.5 101.726) (end 217.5 106.226) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960B)) + (gr_line (start 214 106.226) (end 214 101.726) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960A)) + (gr_line (start 217.5 106.226) (end 214 106.226) (layer Edge.Cuts) (width 0.15) (tstamp 5F809609)) + (gr_line (start 198.45 106.25) (end 194.95 106.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F809608)) + (gr_line (start 175.8488 116.0352) (end 179.3488 116.0352) (layer Edge.Cuts) (width 0.15) (tstamp 5F809607)) + (gr_line (start 175.8488 120.5352) (end 175.8488 116.0352) (layer Edge.Cuts) (width 0.15) (tstamp 5F809606)) + (gr_line (start 156.8504 113.5362) (end 160.3504 113.5362) (layer Edge.Cuts) (width 0.15) (tstamp 5F809605)) + (gr_line (start 141.25 97.05) (end 141.25 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F809604)) + (gr_line (start 198.45 87.25) (end 194.95 87.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F809603)) + (gr_line (start 175.85 77.95) (end 179.35 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F809602)) + (gr_line (start 156.85 94.4308) (end 160.35 94.4308) (layer Edge.Cuts) (width 0.15) (tstamp 5F809601)) + (gr_line (start 160.35 94.4308) (end 160.35 98.9308) (layer Edge.Cuts) (width 0.15) (tstamp 5F809600)) + (gr_line (start 179.35 77.95) (end 179.35 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FF)) + (gr_line (start 194.95 87.25) (end 194.95 82.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FE)) + (gr_line (start 156.8504 118.0362) (end 156.8504 113.5362) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FD)) + (gr_line (start 160.3504 118.0362) (end 156.8504 118.0362) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FC)) + (gr_line (start 141.2504 115.9492) (end 141.2504 120.4492) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FB)) + (gr_line (start 122.25 99.35) (end 122.25 103.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FA)) + (gr_line (start 198.45 101.75) (end 198.45 106.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F9)) + (gr_line (start 175.85 101.55) (end 175.85 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F8)) + (gr_line (start 122.25 103.85) (end 118.75 103.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F7)) + (gr_line (start 137.75 101.55) (end 137.75 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F6)) + (gr_line (start 156.85 98.9308) (end 156.85 94.4308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F5)) + (gr_line (start 175.85 82.45) (end 175.85 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F4)) + (gr_line (start 179.35 101.55) (end 175.85 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F3)) + (gr_line (start 198.45 82.75) (end 198.45 87.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F2)) + (gr_line (start 194.95 106.25) (end 194.95 101.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F1)) + (gr_line (start 179.35 82.45) (end 175.85 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F0)) + (gr_line (start 141.25 101.55) (end 137.75 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095EF)) + (gr_line (start 138.154128 134) (end 93.9 146.75) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095EE)) + (gr_line (start 217.45 82.7895) (end 217.45 87.2895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095ED)) + (gr_line (start 225.026621 43.6956) (end 225.168321 43.835582) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095EC)) + (gr_line (start 122.25 46.75) (end 118.75 46.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095EB)) + (gr_line (start 175.85 39.85) (end 179.35 39.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095EA)) + (gr_line (start 179.35 44.35) (end 175.85 44.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E9)) + (gr_line (start 213.95 63.526) (end 217.45 63.526) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E8)) + (gr_line (start 156.85 41.7308) (end 156.85 37.2308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E7)) + (gr_line (start 89.19368 37.348815) (end 89.425853 37.325405) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095E6)) + (gr_line (start 88.977436 37.415945) (end 89.19368 37.348815) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095E5)) + (gr_line (start 149 35) (end 170.95 35) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095E4)) + (gr_line (start 118.75 42.25) (end 122.25 42.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E3)) + (gr_line (start 137.75 39.7484) (end 141.25 39.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E2)) + (gr_line (start 160.35 37.2308) (end 160.35 41.7308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E1)) + (gr_line (start 194.95 49.15) (end 194.95 44.65) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E0)) + (gr_line (start 198.45 68.05) (end 194.95 68.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DF)) + (gr_line (start 122.25 42.25) (end 122.25 46.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DE)) + (gr_line (start 118.75 46.75) (end 118.75 42.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DD)) + (gr_line (start 213.95 49.1514) (end 213.95 44.6514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DC)) + (gr_line (start 194.95 63.55) (end 198.45 63.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DB)) + (gr_line (start 160.35 41.7308) (end 156.85 41.7308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DA)) + (gr_line (start 213.95 82.7895) (end 217.45 82.7895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D9)) + (gr_line (start 214 101.726) (end 217.5 101.726) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D8)) + (gr_line (start 141.25 44.2484) (end 137.75 44.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D7)) + (gr_line (start 198.45 63.55) (end 198.45 68.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D6)) + (gr_line (start 198.45 49.15) (end 194.95 49.15) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D5)) + (gr_line (start 224.861871 43.581466) (end 225.026621 43.6956) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095D4)) + (gr_line (start 137.75 44.2484) (end 137.75 39.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D3)) + (gr_line (start 213.95 44.6514) (end 217.45 44.6514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D2)) + (gr_line (start 225.168321 43.835582) (end 225.283881 43.997807) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095D1)) + (gr_line (start 179.35 39.85) (end 179.35 44.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D0)) + (gr_line (start 198.45 44.65) (end 198.45 49.15) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CF)) + (gr_line (start 217.45 44.6514) (end 217.45 49.1514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CE)) + (gr_line (start 213.95 68.026) (end 213.95 63.526) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CD)) + (gr_line (start 194.95 44.65) (end 198.45 44.65) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CC)) + (gr_line (start 217.45 63.526) (end 217.45 68.026) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CB)) + (gr_line (start 88.275257 114.4) (end 88.273857 38.477435) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095CA)) + (gr_line (start 175.85 44.35) (end 175.85 39.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C9)) + (gr_line (start 217.45 49.1514) (end 213.95 49.1514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C8)) + (gr_line (start 194.95 68.05) (end 194.95 63.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C7)) + (gr_line (start 217.45 87.2895) (end 213.95 87.2895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C6)) + (gr_line (start 217.45 68.026) (end 213.95 68.026) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C5)) + (gr_line (start 141.25 39.7484) (end 141.25 44.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C4)) + (gr_line (start 213.95 87.2895) (end 213.95 82.7895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C3)) + (gr_line (start 156.85 37.2308) (end 160.35 37.2308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C2)) + (gr_line (start 137.75 82.45) (end 137.75 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C1)) + (gr_line (start 118.75 80.35) (end 122.25 80.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C0)) + (gr_line (start 179.35 58.7484) (end 179.35 63.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BF)) + (gr_line (start 160.35 60.8308) (end 156.85 60.8308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BE)) + (gr_line (start 118.75 84.85) (end 118.75 80.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BD)) + (gr_line (start 118.75 65.85) (end 118.75 61.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BC)) + (gr_line (start 175.85 58.7484) (end 179.35 58.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BB)) + (gr_line (start 137.75 63.45) (end 137.75 58.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BA)) + (gr_line (start 122.25 84.85) (end 118.75 84.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B9)) + (gr_line (start 141.25 63.45) (end 137.75 63.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B8)) + (gr_line (start 122.25 80.35) (end 122.25 84.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B7)) + (gr_line (start 118.75 61.35) (end 122.25 61.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B6)) + (gr_line (start 156.85 56.3308) (end 160.35 56.3308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B5)) + (gr_line (start 156.85 60.8308) (end 156.85 56.3308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B4)) + (gr_line (start 122.25 61.35) (end 122.25 65.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B3)) + (gr_line (start 141.25 58.95) (end 141.25 63.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B2)) + (gr_line (start 160.35 79.9562) (end 156.85 79.9562) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B1)) + (gr_line (start 141.25 82.45) (end 137.75 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B0)) + (gr_line (start 122.25 65.85) (end 118.75 65.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AF)) + (gr_line (start 160.35 56.3308) (end 160.35 60.8308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AE)) + (gr_line (start 137.75 58.95) (end 141.25 58.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AD)) + (gr_line (start 137.75 77.95) (end 141.25 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AC)) + (gr_line (start 141.25 77.95) (end 141.25 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AB)) + (gr_line (start 113.952287 121.332) (end 117.333027 120.426134) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AA)) + (gr_line (start 225.470181 119.5) (end 187.5 134) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A9)) + (gr_line (start 92.9 146.5) (end 93.35 146.65) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A8)) + (gr_line (start 102.5164 128.0486) (end 104.2664 131.079688) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A7)) + (gr_line (start 100.369286 133.329688) (end 98.619286 130.2986) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A6)) + (gr_line (start 82.15 127.9) (end 82.1 127.3) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A5)) + (gr_line (start 93.35 146.65) (end 93.9 146.75) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A4)) + (gr_line (start 175.85 63.2484) (end 175.85 58.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A3)) + (gr_line (start 88.2 115.05) (end 88 115.65) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A2)) + (gr_line (start 117.333027 120.426134) (end 118.497713 124.7728) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A1)) + (gr_line (start 179.35 63.2484) (end 175.85 63.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A0)) + (gr_line (start 82.1 127.3) (end 82.1 126.9) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959F)) + (gr_line (start 115.116973 125.678666) (end 113.952287 121.332) (layer Edge.Cuts) (width 0.15) (tstamp 5F80959E)) + (gr_line (start 82.1 126.9) (end 82.2 126.4) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959D)) + (gr_line (start 82.3 128.4) (end 82.15 127.9) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959C)) + (gr_line (start 88.275257 114.4) (end 88.2 115.05) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959B)) + (gr_line (start 149 35) (end 89.425853 37.325405) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959A)) + (gr_line (start 138.154128 134) (end 187.5 134) (layer Edge.Cuts) (width 0.1) (tstamp 5F809599)) + (gr_line (start 92.55 146.2) (end 92.9 146.5) (layer Edge.Cuts) (width 0.1) (tstamp 5F809598)) + (gr_line (start 98.619286 130.2986) (end 102.5164 128.0486) (layer Edge.Cuts) (width 0.15) (tstamp 5F809597)) + (gr_line (start 118.497713 124.7728) (end 115.116973 125.678666) (layer Edge.Cuts) (width 0.15) (tstamp 5F809596)) + (gr_line (start 104.2664 131.079688) (end 100.369286 133.329688) (layer Edge.Cuts) (width 0.15) (tstamp 5F809595)) + (gr_line (start 88.47059 37.833327) (end 88.611259 37.662831) (layer Edge.Cuts) (width 0.1) (tstamp 5F809594)) + (gr_line (start 224.475441 43.445146) (end 224.677111 43.496776) (layer Edge.Cuts) (width 0.1) (tstamp 5F809593)) + (gr_line (start 224.677111 43.496776) (end 224.861871 43.581466) (layer Edge.Cuts) (width 0.1) (tstamp 5F809592)) + (gr_line (start 88.273857 38.477435) (end 88.297257 38.245261) (layer Edge.Cuts) (width 0.1) (tstamp 5F809591)) + (gr_line (start 88.364377 38.029014) (end 88.47059 37.833327) (layer Edge.Cuts) (width 0.1) (tstamp 5F809590)) + (gr_line (start 82.2 126.4) (end 88 115.65) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958F)) + (gr_line (start 225.370281 44.178672) (end 225.424381 44.374571) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958E)) + (gr_line (start 88.781752 37.52216) (end 88.977436 37.415945) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958D)) + (gr_line (start 225.424381 44.374571) (end 225.443181 44.581902) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958C)) + (gr_line (start 88.611259 37.662831) (end 88.781752 37.52216) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958B)) + (gr_line (start 225.443181 44.581902) (end 225.470181 119.5) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958A)) + (gr_line (start 88.297257 38.245261) (end 88.364377 38.029014) (layer Edge.Cuts) (width 0.1) (tstamp 5F809589)) + (gr_line (start 170.95 35) (end 224.475441 43.445146) (layer Edge.Cuts) (width 0.1) (tstamp 5F809588)) + (gr_line (start 92.55 146.2) (end 82.3 128.4) (layer Edge.Cuts) (width 0.1) (tstamp 5F809587)) + (gr_line (start 225.283881 43.997807) (end 225.370281 44.178672) (layer Edge.Cuts) (width 0.1) (tstamp 5F809586)) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 155.75 132.5) (layer F.SilkS) (tstamp 5F80515B) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 156.9182 132.4021) (layer B.SilkS) (tstamp 5F80515B) + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (gr_text "Sofle RGB by Dane Evans, original by Josef Adamacik" (at 113.75 39) (layer B.SilkS) (tstamp 5F8089F3) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Sofle RGB v3, Dane Evans, JCliment\n" (at 201.4474 127.0762 21) (layer B.Cu) (tstamp 5F80858D) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Sofle RGB v3, Dane Evans, JCliment" (at 201.3458 127.1016 21) (layer F.Cu) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_line (start 93.35 146.65) (end 93.9 146.75) (layer Cmts.User) (width 0.1) (tstamp 5F809492)) + (gr_line (start 92.9 146.5) (end 93.35 146.65) (layer Cmts.User) (width 0.1) (tstamp 5F809486)) + (gr_line (start 92.55 146.2) (end 92.9 146.5) (layer Cmts.User) (width 0.1) (tstamp 5F8094B6)) + (gr_line (start 88.2 115.05) (end 88 115.65) (layer Cmts.User) (width 0.1) (tstamp 5F809498)) + (gr_line (start 88.275257 114.4) (end 88.2 115.05) (layer Cmts.User) (width 0.1) (tstamp 5F8094AD)) + (gr_line (start 82.1 126.9) (end 82.2 126.4) (layer Cmts.User) (width 0.1) (tstamp 5F8094A7)) + (gr_line (start 82.1 127.3) (end 82.1 126.9) (layer Cmts.User) (width 0.1) (tstamp 5F8094A1)) + (gr_line (start 82.15 127.9) (end 82.1 127.3) (layer Cmts.User) (width 0.1) (tstamp 5F80948F)) + (gr_line (start 82.3 128.4) (end 82.15 127.9) (layer Cmts.User) (width 0.1) (tstamp 5F8094AA)) + (gr_line (start 149 35) (end 89.19368 37.348815) (layer Cmts.User) (width 0.1) (tstamp 5F8094B0)) + (gr_line (start 225.5 119.5) (end 187.5 134) (layer Cmts.User) (width 0.15) (tstamp 5F809483)) + (gr_line (start 138.154128 134) (end 187.5 134) (layer Cmts.User) (width 0.1) (tstamp 5F8094B3)) + (gr_text "Ind bypass" (at 114.173 82.804 90) (layer F.SilkS) (tstamp 5F77E038) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_text "BL bypass" (at 187.2234 99.3648 90) (layer F.SilkS) (tstamp 5F77D431) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_text "Ind bypass" (at 114.173 82.804 90) (layer B.SilkS) (tstamp 5F77CE5F) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (gr_text VCC (at 110.109 81.026) (layer F.SilkS) (tstamp 5F77CE5F) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_text LED (at 110.0582 78.613) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_line (start 104.2664 131.079688) (end 100.369286 133.329688) (layer Cmts.User) (width 0.15) (tstamp 5F8094BF)) + (gr_line (start 98.619286 130.2986) (end 102.5164 128.0486) (layer Cmts.User) (width 0.15) (tstamp 5F8094B9)) + (gr_line (start 100.369286 133.329688) (end 98.619286 130.2986) (layer Cmts.User) (width 0.15) (tstamp 5F80948C)) + (gr_line (start 102.5164 128.0486) (end 104.2664 131.079688) (layer Cmts.User) (width 0.15) (tstamp 5F809489)) + (gr_line (start 113.952287 121.332) (end 117.333027 120.426134) (layer Cmts.User) (width 0.15) (tstamp 5F809480)) + (gr_line (start 118.497713 124.7728) (end 115.116973 125.678666) (layer Cmts.User) (width 0.15) (tstamp 5F8094BC)) + (gr_line (start 115.116973 125.678666) (end 113.952287 121.332) (layer Cmts.User) (width 0.15) (tstamp 5F8094A4)) + (gr_line (start 117.333027 120.426134) (end 118.497713 124.7728) (layer Cmts.User) (width 0.15) (tstamp 5F80949B)) + (gr_line (start 179.35 63.2484) (end 175.85 63.2484) (layer Cmts.User) (width 0.15) (tstamp 5F80949E)) + (gr_line (start 175.85 63.2484) (end 175.85 58.7484) (layer Cmts.User) (width 0.15) (tstamp 5F809495)) + (gr_line (start 179.35 58.7484) (end 179.35 63.2484) (layer Cmts.User) (width 0.15) (tstamp 5F809441)) + (gr_line (start 175.85 58.7484) (end 179.35 58.7484) (layer Cmts.User) (width 0.15) (tstamp 5F80944D)) + (gr_line (start 160.35 60.8308) (end 156.85 60.8308) (layer Cmts.User) (width 0.15) (tstamp 5F809444)) + (gr_line (start 156.85 60.8308) (end 156.85 56.3308) (layer Cmts.User) (width 0.15) (tstamp 5F809462)) + (gr_line (start 160.35 56.3308) (end 160.35 60.8308) (layer Cmts.User) (width 0.15) (tstamp 5F809474)) + (gr_line (start 156.85 56.3308) (end 160.35 56.3308) (layer Cmts.User) (width 0.15) (tstamp 5F80945F)) + (gr_line (start 141.25 63.45) (end 137.75 63.45) (layer Cmts.User) (width 0.15) (tstamp 5F809456)) + (gr_line (start 137.75 63.45) (end 137.75 58.95) (layer Cmts.User) (width 0.15) (tstamp 5F809450)) + (gr_line (start 141.25 58.95) (end 141.25 63.45) (layer Cmts.User) (width 0.15) (tstamp 5F809468)) + (gr_line (start 137.75 58.95) (end 141.25 58.95) (layer Cmts.User) (width 0.15) (tstamp 5F809477)) + (gr_line (start 122.25 65.85) (end 118.75 65.85) (layer Cmts.User) (width 0.15) (tstamp 5F809471)) + (gr_line (start 118.75 65.85) (end 118.75 61.35) (layer Cmts.User) (width 0.15) (tstamp 5F80944A)) + (gr_line (start 122.25 61.35) (end 122.25 65.85) (layer Cmts.User) (width 0.15) (tstamp 5F809465)) + (gr_line (start 118.75 61.35) (end 122.25 61.35) (layer Cmts.User) (width 0.15) (tstamp 5F80945C)) + (gr_line (start 122.25 84.85) (end 118.75 84.85) (layer Cmts.User) (width 0.15) (tstamp 5F809453)) + (gr_line (start 118.75 84.85) (end 118.75 80.35) (layer Cmts.User) (width 0.15) (tstamp 5F809447)) + (gr_line (start 122.25 80.35) (end 122.25 84.85) (layer Cmts.User) (width 0.15) (tstamp 5F809459)) + (gr_line (start 118.75 80.35) (end 122.25 80.35) (layer Cmts.User) (width 0.15) (tstamp 5F80943E)) + (gr_line (start 141.25 82.45) (end 137.75 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F80946E)) + (gr_line (start 137.75 82.45) (end 137.75 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F80943B)) + (gr_line (start 141.25 77.95) (end 141.25 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F80947D)) + (gr_line (start 137.75 77.95) (end 141.25 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F80947A)) + (gr_line (start 160.35 79.9562) (end 156.85 79.9562) (layer Cmts.User) (width 0.15) (tstamp 5F80946B)) + (gr_line (start 156.85 79.9562) (end 156.85 75.4562) (layer Cmts.User) (width 0.15) (tstamp 5F809348)) + (gr_line (start 160.35 75.4562) (end 160.35 79.9562) (layer Cmts.User) (width 0.15) (tstamp 5F809357)) + (gr_line (start 156.85 75.4562) (end 160.35 75.4562) (layer Cmts.User) (width 0.15) (tstamp 5F809342)) + (gr_line (start 179.35 82.45) (end 175.85 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F8093AE)) + (gr_line (start 175.85 82.45) (end 175.85 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F8093A2)) + (gr_line (start 179.35 77.95) (end 179.35 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F809381)) + (gr_line (start 175.85 77.95) (end 179.35 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F809378)) + (gr_line (start 198.45 87.25) (end 194.95 87.25) (layer Cmts.User) (width 0.15) (tstamp 5F809375)) + (gr_line (start 194.95 87.25) (end 194.95 82.75) (layer Cmts.User) (width 0.15) (tstamp 5F809384)) + (gr_line (start 198.45 82.75) (end 198.45 87.25) (layer Cmts.User) (width 0.15) (tstamp 5F8093A8)) + (gr_line (start 194.95 82.75) (end 198.45 82.75) (layer Cmts.User) (width 0.15) (tstamp 5F809333)) + (gr_line (start 198.45 106.25) (end 194.95 106.25) (layer Cmts.User) (width 0.15) (tstamp 5F809366)) + (gr_line (start 194.95 106.25) (end 194.95 101.75) (layer Cmts.User) (width 0.15) (tstamp 5F8093AB)) + (gr_line (start 198.45 101.75) (end 198.45 106.25) (layer Cmts.User) (width 0.15) (tstamp 5F809393)) + (gr_line (start 194.95 101.75) (end 198.45 101.75) (layer Cmts.User) (width 0.15) (tstamp 5F809345)) + (gr_line (start 179.35 101.55) (end 175.85 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F8093A5)) + (gr_line (start 175.85 101.55) (end 175.85 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F809396)) + (gr_line (start 179.35 97.05) (end 179.35 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F80932D)) + (gr_line (start 175.85 97.05) (end 179.35 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F809354)) + (gr_line (start 160.35 98.9308) (end 156.85 98.9308) (layer Cmts.User) (width 0.15) (tstamp 5F809339)) + (gr_line (start 156.85 98.9308) (end 156.85 94.4308) (layer Cmts.User) (width 0.15) (tstamp 5F80939F)) + (gr_line (start 160.35 94.4308) (end 160.35 98.9308) (layer Cmts.User) (width 0.15) (tstamp 5F80937E)) + (gr_line (start 156.85 94.4308) (end 160.35 94.4308) (layer Cmts.User) (width 0.15) (tstamp 5F80937B)) + (gr_line (start 141.25 101.55) (end 137.75 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F8093B1)) + (gr_line (start 137.75 101.55) (end 137.75 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F80939C)) + (gr_line (start 141.25 97.05) (end 141.25 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F809372)) + (gr_line (start 137.75 97.05) (end 141.25 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F809351)) + (gr_line (start 122.25 103.85) (end 118.75 103.85) (layer Cmts.User) (width 0.15) (tstamp 5F809399)) + (gr_line (start 118.75 103.85) (end 118.75 99.35) (layer Cmts.User) (width 0.15) (tstamp 5F80934E)) + (gr_line (start 122.25 99.35) (end 122.25 103.85) (layer Cmts.User) (width 0.15) (tstamp 5F809390)) + (gr_line (start 118.75 99.35) (end 122.25 99.35) (layer Cmts.User) (width 0.15) (tstamp 5F80933C)) + (gr_line (start 141.2504 120.4492) (end 137.7504 120.4492) (layer Cmts.User) (width 0.15) (tstamp 5F809336)) + (gr_line (start 137.7504 120.4492) (end 137.7504 115.9492) (layer Cmts.User) (width 0.15) (tstamp 5F80934B)) + (gr_line (start 141.2504 115.9492) (end 141.2504 120.4492) (layer Cmts.User) (width 0.15) (tstamp 5F80938D)) + (gr_line (start 137.7504 115.9492) (end 141.2504 115.9492) (layer Cmts.User) (width 0.15) (tstamp 5F80933F)) + (gr_line (start 160.3504 118.0362) (end 156.8504 118.0362) (layer Cmts.User) (width 0.15) (tstamp 5F80938A)) + (gr_line (start 156.8504 118.0362) (end 156.8504 113.5362) (layer Cmts.User) (width 0.15) (tstamp 5F809387)) + (gr_line (start 160.3504 113.5362) (end 160.3504 118.0362) (layer Cmts.User) (width 0.15) (tstamp 5F809330)) + (gr_line (start 156.8504 113.5362) (end 160.3504 113.5362) (layer Cmts.User) (width 0.15) (tstamp 5F80936F)) + (gr_line (start 179.3488 120.5352) (end 175.8488 120.5352) (layer Cmts.User) (width 0.15) (tstamp 5F80935A)) + (gr_line (start 175.8488 120.5352) (end 175.8488 116.0352) (layer Cmts.User) (width 0.15) (tstamp 5F80936C)) + (gr_line (start 179.3488 116.0352) (end 179.3488 120.5352) (layer Cmts.User) (width 0.15) (tstamp 5F80932A)) + (gr_line (start 175.8488 116.0352) (end 179.3488 116.0352) (layer Cmts.User) (width 0.15) (tstamp 5F809369)) + (gr_line (start 217.5 106.226) (end 214 106.226) (layer Cmts.User) (width 0.15) (tstamp 5F809363)) + (gr_line (start 214 106.226) (end 214 101.726) (layer Cmts.User) (width 0.15) (tstamp 5F809360)) + (gr_line (start 217.5 101.726) (end 217.5 106.226) (layer Cmts.User) (width 0.15) (tstamp 5F80935D)) + (gr_line (start 214 101.726) (end 217.5 101.726) (layer Cmts.User) (width 0.15) (tstamp 5F8093F6)) + (gr_line (start 217.45 87.2895) (end 213.95 87.2895) (layer Cmts.User) (width 0.15) (tstamp 5F80942C)) + (gr_line (start 213.95 87.2895) (end 213.95 82.7895) (layer Cmts.User) (width 0.15) (tstamp 5F809435)) + (gr_line (start 217.45 82.7895) (end 217.45 87.2895) (layer Cmts.User) (width 0.15) (tstamp 5F8093B7)) + (gr_line (start 213.95 82.7895) (end 217.45 82.7895) (layer Cmts.User) (width 0.15) (tstamp 5F8093F3)) + (gr_line (start 198.45 68.05) (end 194.95 68.05) (layer Cmts.User) (width 0.15) (tstamp 5F8093E1)) + (gr_line (start 194.95 68.05) (end 194.95 63.55) (layer Cmts.User) (width 0.15) (tstamp 5F809429)) + (gr_line (start 198.45 63.55) (end 198.45 68.05) (layer Cmts.User) (width 0.15) (tstamp 5F8093FC)) + (gr_line (start 194.95 63.55) (end 198.45 63.55) (layer Cmts.User) (width 0.15) (tstamp 5F8093ED)) + (gr_line (start 217.45 68.026) (end 213.95 68.026) (layer Cmts.User) (width 0.15) (tstamp 5F80942F)) + (gr_line (start 213.95 68.026) (end 213.95 63.526) (layer Cmts.User) (width 0.15) (tstamp 5F809417)) + (gr_line (start 217.45 63.526) (end 217.45 68.026) (layer Cmts.User) (width 0.15) (tstamp 5F80941D)) + (gr_line (start 213.95 63.526) (end 217.45 63.526) (layer Cmts.User) (width 0.15) (tstamp 5F8093C6)) + (gr_line (start 217.45 49.1514) (end 213.95 49.1514) (layer Cmts.User) (width 0.15) (tstamp 5F809426)) + (gr_line (start 213.95 49.1514) (end 213.95 44.6514) (layer Cmts.User) (width 0.15) (tstamp 5F8093EA)) + (gr_line (start 217.45 44.6514) (end 217.45 49.1514) (layer Cmts.User) (width 0.15) (tstamp 5F809414)) + (gr_line (start 213.95 44.6514) (end 217.45 44.6514) (layer Cmts.User) (width 0.15) (tstamp 5F809408)) + (gr_line (start 198.45 49.15) (end 194.95 49.15) (layer Cmts.User) (width 0.15) (tstamp 5F8093FF)) + (gr_line (start 194.95 49.15) (end 194.95 44.65) (layer Cmts.User) (width 0.15) (tstamp 5F8093DE)) + (gr_line (start 198.45 44.65) (end 198.45 49.15) (layer Cmts.User) (width 0.15) (tstamp 5F809411)) + (gr_line (start 194.95 44.65) (end 198.45 44.65) (layer Cmts.User) (width 0.15) (tstamp 5F80941A)) + (gr_line (start 179.35 44.35) (end 175.85 44.35) (layer Cmts.User) (width 0.15) (tstamp 5F8093C3)) + (gr_line (start 175.85 44.35) (end 175.85 39.85) (layer Cmts.User) (width 0.15) (tstamp 5F809423)) + (gr_line (start 179.35 39.85) (end 179.35 44.35) (layer Cmts.User) (width 0.15) (tstamp 5F80940E)) + (gr_line (start 175.85 39.85) (end 179.35 39.85) (layer Cmts.User) (width 0.15) (tstamp 5F8093C0)) + (gr_line (start 156.85 41.7308) (end 156.85 37.2308) (layer Cmts.User) (width 0.15) (tstamp 5F8093C9)) + (gr_line (start 160.35 41.7308) (end 156.85 41.7308) (layer Cmts.User) (width 0.15) (tstamp 5F8093F0)) + (gr_line (start 160.35 37.2308) (end 160.35 41.7308) (layer Cmts.User) (width 0.15) (tstamp 5F8093DB)) + (gr_line (start 156.85 37.2308) (end 160.35 37.2308) (layer Cmts.User) (width 0.15) (tstamp 5F809438)) + (gr_line (start 141.25 39.7484) (end 141.25 44.2484) (layer Cmts.User) (width 0.15) (tstamp 5F809432)) + (gr_line (start 137.75 39.7484) (end 141.25 39.7484) (layer Cmts.User) (width 0.15) (tstamp 5F8093D8)) + (gr_line (start 137.75 44.2484) (end 137.75 39.7484) (layer Cmts.User) (width 0.15) (tstamp 5F809405)) + (gr_line (start 141.25 44.2484) (end 137.75 44.2484) (layer Cmts.User) (width 0.15) (tstamp 5F8093F9)) + (gr_line (start 118.75 46.75) (end 118.75 42.25) (layer Cmts.User) (width 0.15) (tstamp 5F8093E7)) + (gr_line (start 122.25 46.75) (end 118.75 46.75) (layer Cmts.User) (width 0.15) (tstamp 5F8093BD)) + (gr_line (start 122.25 42.25) (end 122.25 46.75) (layer Cmts.User) (width 0.15) (tstamp 5F8093E4)) + (gr_line (start 118.75 42.25) (end 122.25 42.25) (layer Cmts.User) (width 0.15) (tstamp 5F8093D5)) + (gr_circle (center 100.01 104.49) (end 109.96 103.16) (layer Eco1.User) (width 0.15)) + (gr_line (start 225.026621 43.6956) (end 225.168321 43.835582) (layer Cmts.User) (width 0.1) (tstamp 5F8093BA)) + (gr_line (start 149 35) (end 170.95 35) (layer Cmts.User) (width 0.1) (tstamp 5F8093D2)) + (gr_line (start 88.977436 37.415945) (end 89.19368 37.348815) (layer Cmts.User) (width 0.1) (tstamp 5F8093CF)) + (gr_line (start 89.19368 37.348815) (end 89.425853 37.325405) (layer Cmts.User) (width 0.1) (tstamp 5F8093CC)) + (gr_line (start 138.154128 134) (end 93.9 146.75) (layer Cmts.User) (width 0.1) (tstamp 5F8093B4)) + (gr_line (start 88.275257 114.4) (end 88.273857 38.477435) (layer Cmts.User) (width 0.1) (tstamp 5F809420)) + (gr_line (start 225.168321 43.835582) (end 225.283881 43.997807) (layer Cmts.User) (width 0.1) (tstamp 5F80940B)) + (gr_line (start 224.861871 43.581466) (end 225.026621 43.6956) (layer Cmts.User) (width 0.1) (tstamp 5F809402)) + (gr_line (start 88.781752 37.52216) (end 88.977436 37.415945) (layer Cmts.User) (width 0.1) (tstamp 5F8094D7)) + (gr_line (start 225.370281 44.178672) (end 225.424381 44.374571) (layer Cmts.User) (width 0.1) (tstamp 5F8094D4)) + (gr_line (start 88.273857 38.477435) (end 88.297257 38.245261) (layer Cmts.User) (width 0.1) (tstamp 5F8094CB)) + (gr_line (start 170.95 35) (end 224.475441 43.445146) (layer Cmts.User) (width 0.1) (tstamp 5F8094E6)) + (gr_line (start 88.297257 38.245261) (end 88.364377 38.029014) (layer Cmts.User) (width 0.1) (tstamp 5F8094E3)) + (gr_line (start 92.55 146.2) (end 82.3 128.4) (layer Cmts.User) (width 0.1) (tstamp 5F8094E9)) + (gr_line (start 225.424381 44.374571) (end 225.443181 44.581902) (layer Cmts.User) (width 0.1) (tstamp 5F8094DA)) + (gr_line (start 224.677111 43.496776) (end 224.861871 43.581466) (layer Cmts.User) (width 0.1) (tstamp 5F8094C8)) + (gr_line (start 88.47059 37.833327) (end 88.611259 37.662831) (layer Cmts.User) (width 0.1) (tstamp 5F8094C2)) + (gr_line (start 224.475441 43.445146) (end 224.677111 43.496776) (layer Cmts.User) (width 0.1) (tstamp 5F8094C5)) + (gr_line (start 225.283881 43.997807) (end 225.370281 44.178672) (layer Cmts.User) (width 0.1) (tstamp 5F8094EC)) + (gr_line (start 225.443181 44.581902) (end 225.470181 119.5) (layer Cmts.User) (width 0.1) (tstamp 5F8094E0)) + (gr_line (start 88.364377 38.029014) (end 88.47059 37.833327) (layer Cmts.User) (width 0.1) (tstamp 5F8094CE)) + (gr_line (start 88.611259 37.662831) (end 88.781752 37.52216) (layer Cmts.User) (width 0.1) (tstamp 5F8094DD)) + (gr_line (start 82.2 126.4) (end 88 115.65) (layer Cmts.User) (width 0.1) (tstamp 5F8094D1)) + (gr_line (start 49.676679 -38.227998) (end 49.676679 -38.227998) (layer Cmts.User) (width 0.1)) + (gr_line (start 45.503294 -44.952764) (end 45.503294 -44.952764) (layer Eco2.User) (width 0.1)) + + (segment (start 112.55 53.28) (end 113.25 52.58) (width 0.25) (layer F.Cu) (net 1) (tstamp 5F754BC1)) + (via (at 128.75 46.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 1)) + (segment (start 128.75 47.675) (end 128.75 46.4) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 128.75 46.4) (end 128.75 47.675) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 127.5 49.025) (end 128.75 47.775) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 127.5 52.58) (end 127.5 49.025) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 127.5 49.05) (end 127.45 49) (width 0.25) (layer B.Cu) (net 1)) + (via (at 127.45 49) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 1)) + (segment (start 127.5 52.58) (end 127.5 49.05) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 118.684987 48.300011) (end 119.359999 47.624999) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 119.359999 47.624999) (end 121.640001 47.624999) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 122.315013 48.300011) (end 126.750011 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 121.640001 47.624999) (end 122.315013 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 126.750011 48.300011) (end 127.45 49) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 115.167147 48.300011) (end 118.684987 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 113.5 49.967158) (end 115.167147 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 113.5 52.58) (end 113.5 49.967158) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 105.300001 67.100001) (end 105.300001 67.100001) (width 0.25) (layer F.Cu) (net 2) (tstamp 5BEDFB6F)) + (via (at 105.327833 67.072169) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 104.255686 66.000022) (end 105.127834 66.87217) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 94.8 67.14097) (end 95.940948 66.000022) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.127834 66.87217) (end 105.327833 67.072169) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 93.83 69.17) (end 94.8 68.2) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 94.8 68.2) (end 94.8 67.14097) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 92.18 69.17) (end 93.83 69.17) (width 0.25) (layer F.Cu) (net 2) (status 10)) + (segment (start 95.940948 66.000022) (end 104.255686 66.000022) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 106.2 69.8) (end 106.2 67.944336) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 106.77 70.37) (end 106.2 69.8) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 106.2 67.944336) (end 105.527832 67.272168) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 105.527832 67.272168) (end 105.327833 67.072169) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 108.77 70.37) (end 106.77 70.37) (width 0.25) (layer B.Cu) (net 2) (status 10)) + (segment (start 105.3 97) (end 106.25 97) (width 0.25) (layer F.Cu) (net 2)) + (via (at 106.25 97) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 105.225 97) (end 106.25 97) (width 0.25) (layer B.Cu) (net 2)) + (via (at 105.1894 122.6248) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (via (at 122.7738 119.02) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 106.25 97) (end 106.25 98.25) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 106.25 98.25) (end 110 102) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 110 119.2746) (end 108.6498 120.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 110 102) (end 110 119.2746) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.1894 122.6248) (end 105.1894 121.8106) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 106.3752 120.6248) (end 108.6498 120.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.1894 121.8106) (end 106.3752 120.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 124.03 119.02) (end 122.7738 119.02) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 122.7738 119.02) (end 124.03 119.02) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 119.0612) (end 122.7738 119.02) (width 0.25) (layer F.Cu) (net 2)) + (via (at 109.5123 119.7623) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 108.6498 120.6248) (end 109.5123 119.7623) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 108.325001 95.924999) (end 107.325001 95.924999) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.925002 86.247998) (end 109.925002 88.052002) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 107.325001 95.924999) (end 106.25 97) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.925002 88.052002) (end 109.75 88.227004) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.75 88.227004) (end 109.75 94.5) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 108.718815 70.365745) (end 109.750003 71.396933) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.750003 71.396933) (end 109.750003 86.072999) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.750003 86.072999) (end 109.925002 86.247998) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.75 94.5) (end 108.325001 95.924999) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.1894 122.6248) (end 100.8248 122.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 100.8248 122.6248) (end 100.8 122.6) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 100.025 122.6) (end 99.025 123.6) (width 0.25) (layer F.Cu) (net 2)) + (via (at 100.2 122.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 99.2 123.6) (end 100.2 122.6) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 99.025 123.6) (end 99.2 123.6) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 100.8 122.6) (end 100.2 122.6) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 100.2 122.6) (end 100.025 122.6) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 121.02) (end 122.7326 120.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 120.7326) (end 122.7326 119.0612) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.8652 121.6) (end 122.7326 121.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 123.3326) (end 122.7326 121.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 121.7326) (end 122.7326 120.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 124 121.6) (end 122.8652 121.6) (width 0.25) (layer F.Cu) (net 2)) + (via (at 122.7326 121.7326) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 124 121.6) (end 122.8652 121.6) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 122.8652 121.6) (end 122.7326 121.7326) (width 0.25) (layer B.Cu) (net 2)) + (via (at 122.7326 123.3326) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 122.7326 123.9326) (end 122.7326 123.3326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 124 124.2) (end 123 124.2) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 123 124.2) (end 122.7326 123.9326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 123.9326) (end 122.7326 123.3326) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 124 124.2) (end 123 124.2) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 123 124.2) (end 122.7326 123.9326) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 111.0746 118.2) (end 109.5123 119.7623) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 122.7738 119.02) (end 121.9538 118.2) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 121.9538 118.2) (end 111.0746 118.2) (width 0.25) (layer B.Cu) (net 2)) + (via (at 131 46.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 3)) + (segment (start 131 47.425) (end 131 46.15) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 131 46.15) (end 131 47.425) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 131 48.58) (end 132.5 50.08) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 131 47.5555) (end 131 48.58) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 146.5 50.13) (end 146.5 53.45) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 132.5 51.364014) (end 136.388497 55.252511) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 146.5 53.45) (end 144.49749 55.45251) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 144.49749 55.45251) (end 136.588496 55.45251) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 136.388497 55.252511) (end 136.588496 55.45251) (width 0.25) (layer F.Cu) (net 3)) + (via (at 136.588496 55.45251) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 3)) + (segment (start 132.5 50.13) (end 132.5 51.364014) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 165.25 47.87) (end 165.25 52.19) (width 0.25) (layer B.Cu) (net 4) (tstamp 5F754BBC)) + (segment (start 150.55 49.64) (end 150.55 48.57) (width 0.25) (layer F.Cu) (net 4) (tstamp 5F754BBD)) + (segment (start 150.55 48.57) (end 151.25 47.87) (width 0.25) (layer F.Cu) (net 4) (tstamp 5F754BC1)) + (via (at 150.55 49.64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 4) (tstamp 5F754BC7)) + (segment (start 151.6 47.58) (end 151.6 45.915) (width 0.25) (layer F.Cu) (net 4)) + (via (at 151.3625 45.6775) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 4)) + (segment (start 150.5 44.815) (end 151.3625 45.6775) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 151.6 45.915) (end 151.3625 45.6775) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 151.3625 45.6775) (end 150.5 44.815) (width 0.25) (layer B.Cu) (net 4)) + (via (at 165.25 52.19) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 4)) + (segment (start 165.25 54.54) (end 165.25 52.19) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 164.3 55.49) (end 165.25 54.54) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 154.424812 55.49) (end 164.3 55.49) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 150.55 49.64) (end 150.55 51.615188) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 150.55 51.615188) (end 154.424812 55.49) (width 0.25) (layer F.Cu) (net 4)) + (via (at 105.7 59) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 92.18 59.01) (end 105.69 59.01) (width 0.25) (layer F.Cu) (net 5) (status 10)) + (segment (start 105.69 59.01) (end 105.7 59) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 106.91 60.21) (end 105.899999 59.199999) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 105.899999 59.199999) (end 105.7 59) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 108.77 60.21) (end 106.91 60.21) (width 0.25) (layer B.Cu) (net 5) (status 10)) + (via (at 188 49.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 188 48.475) (end 188 49.75) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 188 49.75) (end 188 48.475) (width 0.25) (layer B.Cu) (net 5)) + (via (at 169.25 45.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 169.25 43.875) (end 169.25 45.15) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 169.25 45.15) (end 169.25 43.875) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 184.749999 45.224999) (end 188 48.475) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130.75 44.125) (end 131 43.875) (width 0.25) (layer F.Cu) (net 5)) + (via (at 130 43.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 129.975 43.875) (end 130 43.9) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 131 43.875) (end 129.975 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 169.109999 43.734999) (end 169.25 43.875) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130.975 43.9) (end 131 43.875) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130 43.9) (end 130.975 43.9) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 128.975 43.9) (end 128.75 44.125) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130 43.9) (end 128.975 43.9) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 207.75 48.25) (end 206.75 48.25) (width 0.25) (layer B.Cu) (net 5)) + (via (at 206.75 48.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 207.75 48.25) (end 206.75 48.25) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 129.975 43.975) (end 127.375 43.975) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 127.375 43.975) (end 126.75 44.6) (width 0.25) (layer B.Cu) (net 5)) + (via (at 126.75 44.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (via (at 137.45 45.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 206.5 48.5) (end 206.75 48.25) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 123.55 47.8) (end 126.75 44.6) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 119.173599 47.174988) (end 121.826401 47.174988) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 118.548588 47.8) (end 119.173599 47.174988) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 110.457443 60.205745) (end 111.9 58.763188) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 121.826401 47.174988) (end 122.451412 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 114.922998 47.8) (end 118.548588 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 108.718815 60.205745) (end 110.457443 60.205745) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 111.9 58.763188) (end 111.9 50.822998) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 122.451412 47.8) (end 123.55 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 111.9 50.822998) (end 114.922998 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.15 43.75) (end 169.25 43.65) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 132.188589 43.875) (end 131 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 132.323113 43.875) (end 132.188589 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 137.45 45.6) (end 134.048113 45.6) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 134.048113 45.6) (end 132.323113 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 204.646 50) (end 204.6588 50.0128) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 188 49.75) (end 188.25 50) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 188.25 50) (end 204.646 50) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 205 50) (end 206.5 48.5) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 204.646 50) (end 205 50) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.892499 42.624999) (end 153.534999 42.624999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 159.740001 47.375001) (end 161.544 45.571002) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 153.534999 42.624999) (end 156 45.09) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 156 45.09) (end 156 45.915002) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 157.459999 47.375001) (end 159.740001 47.375001) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 41.265) (end 150.5 42.2325) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 42.2325) (end 150.892499 42.624999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 156 45.915002) (end 157.459999 47.375001) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 161.544 45.571002) (end 161.544 44.5262) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.1356 43.5356) (end 169.25 43.65) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 161.544 44.5262) (end 162.5346 43.5356) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 162.5346 43.5356) (end 169.1356 43.5356) (width 0.25) (layer F.Cu) (net 5)) + (via (at 150.500004 42.222496) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 150.5 42.222492) (end 150.500004 42.222496) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 138.049992 45.000008) (end 147.722492 45.000008) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 147.722492 45.000008) (end 150.500004 42.222496) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 41.265) (end 150.5 42.222492) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 150.5 41.265) (end 150.5 42.222492) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 137.45 45.6) (end 138.049992 45.000008) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 42.222492) (end 150.500004 42.222496) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 173.852004 45.124999) (end 184.749999 45.124999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 173.380763 45.59624) (end 173.852004 45.124999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.69624 45.59624) (end 173.380763 45.59624) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.25 45.15) (end 169.69624 45.59624) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 184.6 54.4) (end 183.624999 55.375001) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBB)) + (segment (start 184.6 50.08) (end 184.6 54.4) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBC)) + (segment (start 169.9 51.85) (end 169.9 50.78) (width 0.25) (layer F.Cu) (net 6) (tstamp 5F754BBD)) + (segment (start 183.624999 55.375001) (end 170.624999 55.375001) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBE)) + (segment (start 170.624999 55.375001) (end 169.9 54.650002) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBF)) + (segment (start 169.9 54.650002) (end 169.9 51.85) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BC0)) + (segment (start 169.9 50.78) (end 170.6 50.08) (width 0.25) (layer F.Cu) (net 6) (tstamp 5F754BC1)) + (via (at 169.9 51.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 6) (tstamp 5F754BC7)) + (segment (start 169.25 48.73) (end 170.6 50.08) (width 0.25) (layer F.Cu) (net 6)) + (segment (start 169.25 47.425) (end 169.25 48.73) (width 0.25) (layer F.Cu) (net 6)) + (via (at 169.25 46.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 6)) + (segment (start 169.25 47.425) (end 169.25 46.15) (width 0.25) (layer F.Cu) (net 6)) + (segment (start 169.25 46.15) (end 169.25 47.425) (width 0.25) (layer B.Cu) (net 6)) + (segment (start 92.23 61.45) (end 105.25 61.45) (width 0.25) (layer F.Cu) (net 7) (status 10)) + (segment (start 105.25 61.45) (end 105.500001 61.700001) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 105.500001 61.700001) (end 105.7 61.9) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 106.55 62.75) (end 105.899999 62.099999) (width 0.25) (layer B.Cu) (net 7)) + (via (at 105.7 61.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 105.899999 62.099999) (end 105.7 61.9) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 108.77 62.75) (end 106.55 62.75) (width 0.25) (layer B.Cu) (net 7) (status 10)) + (segment (start 150.25 59.29) (end 151.25 59.29) (width 0.25) (layer B.Cu) (net 7)) + (via (at 151.5 59.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 151.25 59.29) (end 151.5 59.54) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 150.25 59.29) (end 151.25 59.29) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 151.25 59.29) (end 151.5 59.54) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 183.724999 64.124999) (end 184.5 64.9) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 184.5 65) (end 188.25 65) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 171.725 61.875) (end 173.974999 64.124999) (width 0.25) (layer F.Cu) (net 7)) + (via (at 170.775 61.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 169.5 61.875) (end 170.775 61.875) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 169.5 61.875) (end 170.775 61.875) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 170.775 61.875) (end 171.725 61.875) (width 0.25) (layer F.Cu) (net 7)) + (via (at 146.5326 61.0616) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 188.25 65) (end 189.5 65) (width 0.25) (layer B.Cu) (net 7)) + (via (at 189.5 65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 188.25 65) (end 189.5 65) (width 0.25) (layer F.Cu) (net 7)) + (via (at 206.5 65.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 207.75 65.5) (end 206.5 65.5) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 207.75 65.5) (end 206.5 65.5) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 206.5 65.5) (end 206.25 65.5) (width 0.25) (layer B.Cu) (net 7)) + (via (at 189.5 67.55) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 189.5 67.55) (end 189.5 65) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 108.718815 62.745745) (end 111.520735 62.745745) (width 0.25) (layer F.Cu) (net 7)) + (via (at 111.57499 62.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 111.520735 62.745745) (end 111.57499 62.8) (width 0.25) (layer F.Cu) (net 7)) + (via (at 200.65 68.35) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 153.428 61.468) (end 151.5 59.54) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 169.5 61.875) (end 169.093 61.468) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 169.093 61.468) (end 153.428 61.468) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 183.724999 64.124999) (end 173.974999 64.124999) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 146.2384 61.0616) (end 146.5326 61.0616) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 133.422 63.75) (end 133.722 64.05) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 133.722 64.05) (end 143.25 64.05) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 143.25 64.05) (end 146.2384 61.0616) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 147 60.5942) (end 146.5326 61.0616) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 147 60.2894) (end 147 60.5942) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 150.25 59.29) (end 147.9994 59.29) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 147.9994 59.29) (end 147 60.2894) (width 0.25) (layer F.Cu) (net 7)) + (via (at 202.565 67.31) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 201.525 68.35) (end 202.565 67.31) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 206.5 65.5) (end 204.375 65.5) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 204.375 65.5) (end 202.565 67.31) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 200.65 68.35) (end 201.525 68.35) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 200.525012 68.474988) (end 200.65 68.35) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 189.5 67.55) (end 190.424988 68.474988) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 190.424988 68.474988) (end 200.525012 68.474988) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 129.8 62.025) (end 129.8 62.4) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 129.8 62.4) (end 128.239998 62.4) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 127.839998 62) (end 128.239998 62.4) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 126.8 62) (end 127.839998 62) (width 0.25) (layer B.Cu) (net 7)) + (via (at 128.239998 62.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 126.8 62) (end 127.839998 62) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 127.839998 62) (end 128.239998 62.4) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 129.425 62.4) (end 129.8 62.025) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 128.239998 62.4) (end 129.425 62.4) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 115.499989 66.724999) (end 111.57499 62.8) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 121.915002 67) (end 121.640001 66.724999) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 121.640001 66.724999) (end 115.499989 66.724999) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 128.239998 62.4) (end 123.639998 67) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 123.639998 67) (end 121.915002 67) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 133.422 63.75) (end 132.55 63.75) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 130.825 62.025) (end 129.8 62.025) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 132.55 63.75) (end 130.825 62.025) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 188.8 55.78) (end 189.5 55.08) (width 0.25) (layer F.Cu) (net 8) (tstamp 5F754BC1)) + (via (at 188 50.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 8)) + (segment (start 188 52.025) (end 188 50.75) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 188 50.75) (end 188 52.025) (width 0.25) (layer B.Cu) (net 8)) + (segment (start 188.75 55.93) (end 189.7 54.98) (width 0.25) (layer F.Cu) (net 8)) + (via (at 203.8 53.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 8)) + (segment (start 203.8 54.88) (end 203.7 54.98) (width 0.25) (layer B.Cu) (net 8)) + (segment (start 203.8 53.2) (end 203.8 54.88) (width 0.25) (layer B.Cu) (net 8)) + (segment (start 189.7 54.98) (end 189.7 52) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 188.025 52) (end 188 52.025) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 189.7 52) (end 188.025 52) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 203.8 52.532998) (end 203.8 53.2) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 200.858501 50.791499) (end 202.058501 50.791499) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 202.058501 50.791499) (end 203.8 52.532998) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 192.449978 50.9) (end 193.766001 52.216023) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 193.766001 52.216023) (end 193.766001 52.981003) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 189.7 52) (end 190.8 50.9) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 190.8 50.9) (end 192.449978 50.9) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 193.766001 52.981003) (end 195.559999 54.775001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 198.074999 54.775001) (end 200.024999 52.825001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 195.559999 54.775001) (end 198.074999 54.775001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 200.024999 51.625001) (end 200.858501 50.791499) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 200.024999 52.825001) (end 200.024999 51.625001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 93.905755 64.09) (end 93.995755 64) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 92.18 64.09) (end 93.905755 64.09) (width 0.25) (layer F.Cu) (net 9) (status 10)) + (segment (start 93.995755 64) (end 105.417158 64) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 106.985745 65.285745) (end 105.899999 64.199999) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 105.417158 64) (end 105.7 64) (width 0.25) (layer F.Cu) (net 9)) + (via (at 105.7 64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 108.718815 65.285745) (end 106.985745 65.285745) (width 0.25) (layer B.Cu) (net 9) (status 10)) + (segment (start 105.899999 64.199999) (end 105.7 64) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 131.25 81.9) (end 128.75 81.9) (width 0.25) (layer F.Cu) (net 9)) + (via (at 149.75 80.94) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 149.75 79.69) (end 149.75 80.94) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 149.75 80.94) (end 149.75 79.69) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 188.5 87) (end 188.5 88.25) (width 0.25) (layer B.Cu) (net 9)) + (via (at 188.5 88.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 188.5 87) (end 188.5 88.25) (width 0.25) (layer F.Cu) (net 9)) + (via (at 113.25 77.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (via (at 147.500012 82.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (via (at 206.825 84.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 207.75 84.5) (end 206.825 84.5) (width 0.25) (layer B.Cu) (net 9)) + (via (at 130 81.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 131.25 81.9) (end 130 81.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 128.5 81.9) (end 130 81.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 109.908328 66.475258) (end 109.908328 69.310086) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 108.718815 65.285745) (end 109.908328 66.475258) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 109.908328 69.310086) (end 112.000022 71.40178) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 112.000022 71.40178) (end 112.000022 76.500022) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 112.000022 76.500022) (end 113.050001 77.550001) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 113.050001 77.550001) (end 113.25 77.75) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 146.750012 82.8) (end 147.500012 82.05) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 131.25 81.9) (end 132.25 82.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 132.25 82.8) (end 146.750012 82.8) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 173.25 82.9) (end 172 81.65) (width 0.25) (layer B.Cu) (net 9)) + (via (at 170.48 81.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 169.725 81.65) (end 170.48 81.65) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 172 81.65) (end 170.48 81.65) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 170.48 81.65) (end 169.725 81.65) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 127.489 81.839) (end 128.408 81.839) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 113.25 77.75) (end 123.4 77.75) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 128.408 81.839) (end 128.5 81.931) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 123.4 77.75) (end 127.489 81.839) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 207.75 84.5) (end 206.825 84.5) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 148.610012 80.94) (end 147.500012 82.05) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 149.75 80.94) (end 148.610012 80.94) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 169.725 81.65) (end 166.8162 81.65) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 160.92342 81.01502) (end 160.92341 81.01501) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 166.8162 81.65) (end 166.18122 81.01502) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 166.18122 81.01502) (end 160.92342 81.01502) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 160.92342 81.01502) (end 159.946834 81.01502) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 159.288024 80.35621) (end 156.684311 80.35621) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 150.2748 80.3148) (end 149.75 79.79) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 159.946834 81.01502) (end 159.288024 80.35621) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 156.684311 80.35621) (end 156.642901 80.3148) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 156.642901 80.3148) (end 150.2748 80.3148) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 204.922996 84.5) (end 206.825 84.5) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 202.618496 86.8045) (end 204.922996 84.5) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 189.003 87.503) (end 194.637301 87.503) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 199.461199 86.8045) (end 202.618496 86.8045) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 188.5 87) (end 189.003 87.503) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 194.637301 87.503) (end 194.784311 87.65001) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 194.784311 87.65001) (end 198.615689 87.65001) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 198.615689 87.65001) (end 199.461199 86.8045) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 176.45 82.9) (end 176.1292 82.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 176.1292 82.9) (end 173.25 82.9) (width 0.25) (layer B.Cu) (net 9)) + (via (at 184.15 82.9056) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 184.1444 82.9) (end 184.15 82.9056) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 176.45 82.9) (end 184.1444 82.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 184.15 82.9056) (end 186.0296 82.9056) (width 0.25) (layer F.Cu) (net 9)) + (via (at 186.0296 82.9056) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 188.5 85.376) (end 188.5 87) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 186.0296 82.9056) (end 188.5 85.376) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 208 55.68) (end 208.7 54.98) (width 0.25) (layer F.Cu) (net 10) (tstamp 5F754BC1)) + (segment (start 209 54.68) (end 208.7 54.98) (width 0.25) (layer F.Cu) (net 10)) + (via (at 207.75 53) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 10)) + (segment (start 207.75 51.8) (end 207.75 53) (width 0.25) (layer B.Cu) (net 10)) + (segment (start 207.75 53) (end 207.75 51.8) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 220.70879 60.29121) (end 214.6554 60.29121) (width 0.25) (layer B.Cu) (net 10)) + (via (at 214.6554 60.29121) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 10)) + (segment (start 222.7 58.3) (end 220.70879 60.29121) (width 0.25) (layer B.Cu) (net 10)) + (segment (start 222.7 54.98) (end 222.7 58.3) (width 0.25) (layer B.Cu) (net 10)) + (segment (start 212.79281 60.29121) (end 214.6554 60.29121) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 208.7 54.98) (end 208.7 56.1984) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 208.7 56.1984) (end 212.79281 60.29121) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 207.75 54.03) (end 207.75 53) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 208.7 54.98) (end 207.75 54.03) (width 0.25) (layer F.Cu) (net 10)) + (via (at 105.6 65.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 105.5 65.1) (end 105.6 65.2) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 95.5 65.1) (end 105.5 65.1) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 93.97 66.63) (end 95.5 65.1) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 92.18 66.63) (end 93.97 66.63) (width 0.25) (layer F.Cu) (net 11) (status 10)) + (segment (start 106.887507 67.83) (end 106.2 67.142493) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 106.2 67.142493) (end 106.2 65.8) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 106.2 65.8) (end 105.799999 65.399999) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 105.799999 65.399999) (end 105.6 65.2) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 108.77 67.83) (end 106.887507 67.83) (width 0.25) (layer B.Cu) (net 11) (status 10)) + (via (at 112 102.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 112 100.975) (end 112 102.25) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 112 102.25) (end 112 100.975) (width 0.25) (layer B.Cu) (net 11)) + (via (at 150 97.94) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 150 96.69) (end 150 97.94) (width 0.25) (layer F.Cu) (net 11)) + (via (at 111.350001 97.825012) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 112 100.975) (end 112 98.475011) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112 98.475011) (end 111.350001 97.825012) (width 0.25) (layer B.Cu) (net 11)) + (via (at 189.3875 105.8625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 188.5 104.975) (end 189.3875 105.8625) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 189.3875 105.8625) (end 188.5 104.975) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 169.25 94.15) (end 182.5 94.15) (width 0.25) (layer B.Cu) (net 11)) + (via (at 169.25 98.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 169.25 100.375) (end 169.25 98.9) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 169.25 100.375) (end 169.25 98.9) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 169.25 98.9) (end 169.25 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 183 94.15) (end 183.25 94.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 182.5 94.15) (end 183 94.15) (width 0.25) (layer B.Cu) (net 11)) + (via (at 186 94.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 183.25 94.4) (end 186 94.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 188.5 97) (end 188.5 104.975) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 186 94.5) (end 188.5 97) (width 0.25) (layer F.Cu) (net 11)) + (via (at 129.75 101.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 131 101.4) (end 129.75 101.4) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 129.392998 101.4) (end 129.75 101.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 129.75 101.4) (end 131 101.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 164.249977 92.289977) (end 166.110001 94.150001) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 150 97.94) (end 150 94.1708) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 155.147998 92.289977) (end 164.249977 92.289977) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 149.987 94.1578) (end 151.2316 92.9132) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 166.110001 94.150001) (end 169.249999 94.150001) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 151.2316 92.9132) (end 154.524775 92.9132) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 169.249999 94.150001) (end 169.25 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 150 94.1708) (end 149.987 94.1578) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 154.524775 92.9132) (end 155.147998 92.289977) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 189.3875 105.8625) (end 190.17501 106.65001) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 190.17501 106.65001) (end 202.87601 106.65001) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 129.289998 101.397) (end 129.424 101.397) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 126.571998 98.679) (end 129.289998 101.397) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 114.071 98.679) (end 126.571998 98.679) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112 100.975) (end 112 100.75) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112 100.75) (end 114.071 98.679) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 131 101.4) (end 131.625 101.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 133.5 99.525) (end 133.5 96.3) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 131.625 101.4) (end 133.5 99.525) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 110.25 88.363415) (end 110.25 96.8) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 108.718815 68.815588) (end 110.25 70.346773) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.25 70.346773) (end 110.25 85.936585) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.375013 86.061598) (end 110.375013 88.238402) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.25 96.8) (end 111.275012 97.825012) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.375013 88.238402) (end 110.25 88.363415) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.25 85.936585) (end 110.375013 86.061598) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 108.718815 67.825745) (end 108.718815 68.815588) (width 0.25) (layer F.Cu) (net 11)) + (via (at 207.057999 103.273747) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 208.2 103.4) (end 207.184252 103.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 208.2 103.4) (end 207.184252 103.4) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 207.184252 103.4) (end 207.057999 103.273747) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 207.184252 103.4) (end 207.057999 103.273747) (width 0.25) (layer F.Cu) (net 11)) + (via (at 205.8 104) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 206.526253 103.273747) (end 207.057999 103.273747) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 205.8 104) (end 206.526253 103.273747) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 202.87601 106.65001) (end 203.14999 106.65001) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 204.6 105.2) (end 205.8 104) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 203.14999 106.65001) (end 204.6 105.2) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 135.65 94.15) (end 135.2962 94.5038) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 133.5 96.3) (end 135.2962 94.5038) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 136.0248 94.15) (end 150 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 136.0248 94.15) (end 135.65 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 135.75 94.15) (end 136.0248 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112.75 72.58) (end 112.75 75.65) (width 0.25) (layer F.Cu) (net 12)) + (via (at 112.75 75.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 12)) + (segment (start 113.5 71.83) (end 112.75 72.58) (width 0.25) (layer F.Cu) (net 12)) + (segment (start 114.225001 77.125001) (end 112.75 75.65) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 125.824999 77.125001) (end 114.225001 77.125001) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 127.5 71.83) (end 127.5 75.45) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 127.5 75.45) (end 125.824999 77.125001) (width 0.25) (layer B.Cu) (net 12)) + (via (at 126.8 66.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 12)) + (segment (start 126.8 65.55) (end 126.8 66.6) (width 0.25) (layer F.Cu) (net 12)) + (segment (start 126.8 66.6) (end 126.8 65.55) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 127.5 67.3) (end 127.5 71.68) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 126.8 66.6) (end 127.5 67.3) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 146.5 73.45) (end 145.524999 74.425001) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBB)) + (segment (start 146.5 69.13) (end 146.5 73.45) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBC)) + (segment (start 131.8 70.9) (end 131.8 69.83) (width 0.25) (layer F.Cu) (net 13) (tstamp 5F754BBD)) + (segment (start 145.524999 74.425001) (end 132.524999 74.425001) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBE)) + (segment (start 132.524999 74.425001) (end 131.8 73.700002) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBF)) + (segment (start 131.8 73.700002) (end 131.8 70.9) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BC0)) + (segment (start 131.8 69.83) (end 132.5 69.13) (width 0.25) (layer F.Cu) (net 13) (tstamp 5F754BC1)) + (via (at 131.8 70.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 13) (tstamp 5F754BC7)) + (via (at 131 65.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 13)) + (segment (start 129.8 65.575) (end 130.975 65.575) (width 0.25) (layer B.Cu) (net 13)) + (segment (start 130.975 65.575) (end 131 65.6) (width 0.25) (layer B.Cu) (net 13)) + (segment (start 129.825 65.6) (end 129.8 65.575) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 131 65.6) (end 129.825 65.6) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 131 65.6) (end 132.5 67.1) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 132.5 69.08) (end 132.5 67.1) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 165.6 70.99) (end 164.624999 71.965001) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBB)) + (segment (start 165.6 66.67) (end 165.6 70.99) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBC)) + (segment (start 150.9 68.44) (end 150.9 67.37) (width 0.25) (layer F.Cu) (net 14) (tstamp 5F754BBD)) + (segment (start 164.624999 71.965001) (end 151.624999 71.965001) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBE)) + (segment (start 151.624999 71.965001) (end 150.9 71.240002) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBF)) + (segment (start 150.9 71.240002) (end 150.9 68.44) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BC0)) + (segment (start 150.9 67.37) (end 151.6 66.67) (width 0.25) (layer F.Cu) (net 14) (tstamp 5F754BC1)) + (via (at 150.9 68.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 14) (tstamp 5F754BC7)) + (segment (start 151.6 66.67) (end 151.6 65.89) (width 0.25) (layer F.Cu) (net 14)) + (segment (start 150.25 64.54) (end 150.25 62.84) (width 0.25) (layer F.Cu) (net 14)) + (segment (start 151.6 65.89) (end 150.25 64.54) (width 0.25) (layer F.Cu) (net 14)) + (via (at 150.25 61.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 14)) + (segment (start 150.25 62.84) (end 150.25 61.54) (width 0.25) (layer F.Cu) (net 14)) + (segment (start 150.25 61.54) (end 150.25 62.84) (width 0.25) (layer B.Cu) (net 14)) + (segment (start 184.6 73.4) (end 183.624999 74.375001) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBB)) + (segment (start 184.6 69.08) (end 184.6 73.4) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBC)) + (segment (start 169.9 70.85) (end 169.9 69.78) (width 0.25) (layer F.Cu) (net 15) (tstamp 5F754BBD)) + (segment (start 183.624999 74.375001) (end 170.624999 74.375001) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBE)) + (segment (start 170.624999 74.375001) (end 169.9 73.650002) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBF)) + (segment (start 169.9 73.650002) (end 169.9 70.85) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BC0)) + (segment (start 169.9 69.78) (end 170.6 69.08) (width 0.25) (layer F.Cu) (net 15) (tstamp 5F754BC1)) + (via (at 169.9 70.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 15) (tstamp 5F754BC7)) + (segment (start 170.6 69.08) (end 170.6 66.525) (width 0.25) (layer F.Cu) (net 15)) + (via (at 170.4875 66.4125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 15)) + (segment (start 169.5 65.425) (end 170.4875 66.4125) (width 0.25) (layer B.Cu) (net 15)) + (segment (start 170.6 66.525) (end 170.4875 66.4125) (width 0.25) (layer F.Cu) (net 15)) + (segment (start 170.4875 66.4125) (end 169.5 65.425) (width 0.25) (layer F.Cu) (net 15)) + (segment (start 189 74.58) (end 189.7 73.88) (width 0.25) (layer F.Cu) (net 16) (tstamp 5F754BC1)) + (segment (start 189.7 73.88) (end 189.7 69.8) (width 0.25) (layer F.Cu) (net 16)) + (via (at 204 71.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 16)) + (segment (start 204 73.58) (end 203.7 73.88) (width 0.25) (layer B.Cu) (net 16)) + (segment (start 204 71.75) (end 204 73.58) (width 0.25) (layer B.Cu) (net 16)) + (via (at 188.25 67.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 16)) + (segment (start 188.25 68.55) (end 188.25 67.5) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 188.25 67.5) (end 188.25 68.55) (width 0.25) (layer B.Cu) (net 16)) + (segment (start 189.7 69.8) (end 189.7 68.924999) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 189.325001 68.55) (end 189.7 68.924999) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 188.25 68.55) (end 189.325001 68.55) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 204 71.467158) (end 204 71.75) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 189.7 68.924999) (end 201.457841 68.924999) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 201.457841 68.924999) (end 204 71.467158) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 223.5 73.08) (end 222.7 73.88) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 208.7 73.88) (end 208.7 72.2) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.7 72.2) (end 207.75 71.25) (width 0.25) (layer F.Cu) (net 17)) + (via (at 207.75 70.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 17)) + (segment (start 207.75 71.25) (end 207.75 70.5) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 207.75 69.05) (end 207.75 70.5) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 207.75 70.5) (end 207.75 69.05) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.75 74.08) (end 208.25 74.58) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 222.75 74.08) (end 222.75 77.45) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 208.7 73.88) (end 208.7 75.13) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.7 75.13) (end 211.322 77.752) (width 0.25) (layer F.Cu) (net 17)) + (via (at 216.027 79.074989) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 17)) + (segment (start 212.644989 79.074989) (end 216.027 79.074989) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.7 75.13) (end 212.644989 79.074989) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 221.125011 79.074989) (end 222.75 77.45) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 216.027 79.074989) (end 221.125011 79.074989) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 113.05 92.6) (end 113.05 91.53) (width 0.25) (layer F.Cu) (net 18) (tstamp 5F754BBD)) + (segment (start 113.05 91.53) (end 113.75 90.83) (width 0.25) (layer F.Cu) (net 18) (tstamp 5F754BC1)) + (via (at 113.05 92.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 18) (tstamp 5F754BC7)) + (segment (start 128.5 89.68) (end 127.5 90.68) (width 0.25) (layer B.Cu) (net 18)) + (via (at 128.5 86.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 18)) + (segment (start 128.5 85.7) (end 128.5 86.9) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 128.5 86.9) (end 128.5 89.58) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 128.5 85.7) (end 128.5 86.9) (width 0.25) (layer F.Cu) (net 18)) + (segment (start 113.05 94.254) (end 113.05 92.6) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 125.997999 96.125001) (end 114.921001 96.125001) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 127.75 90.83) (end 127.75 94.373) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 114.921001 96.125001) (end 113.05 94.254) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 127.75 94.373) (end 125.997999 96.125001) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 131.55 89.9) (end 131.55 88.83) (width 0.25) (layer F.Cu) (net 19) (tstamp 5F754BBD)) + (segment (start 131.55 88.83) (end 132.25 88.13) (width 0.25) (layer F.Cu) (net 19) (tstamp 5F754BC1)) + (via (at 131.55 89.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 19) (tstamp 5F754BC7)) + (segment (start 131.25 86.93) (end 132.5 88.18) (width 0.25) (layer F.Cu) (net 19)) + (segment (start 131.25 85.45) (end 131.25 86.93) (width 0.25) (layer F.Cu) (net 19)) + (segment (start 131.25 89.7) (end 131.55 90) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 131.25 85.45) (end 131.25 89.7) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 146.25 88.13) (end 146.25 92.45) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 146.25 92.45) (end 145.650001 93.049999) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 145.650001 93.049999) (end 133.386409 93.049999) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 131.55 91.21359) (end 131.55 89.9) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 133.386409 93.049999) (end 131.55 91.21359) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 150.8 87.64) (end 150.8 86.57) (width 0.25) (layer F.Cu) (net 20) (tstamp 5F754BBD)) + (segment (start 150.8 86.57) (end 151.5 85.87) (width 0.25) (layer F.Cu) (net 20) (tstamp 5F754BC1)) + (via (at 150.8 87.64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 20) (tstamp 5F754BC7)) + (segment (start 149.75 83.92) (end 151.6 85.77) (width 0.25) (layer F.Cu) (net 20)) + (segment (start 149.75 83.24) (end 149.75 83.82) (width 0.25) (layer F.Cu) (net 20)) + (segment (start 149.75 86.59) (end 150.8 87.64) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 149.75 83.24) (end 149.75 86.49) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 150.8 89.0145) (end 150.8 87.64) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 152.950501 91.165001) (end 150.8 89.0145) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 165.5 85.87) (end 165.5 90.19) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 164.524999 91.165001) (end 152.950501 91.165001) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 165.5 90.19) (end 164.524999 91.165001) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 184.6 92.5) (end 183.624999 93.475001) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBB)) + (segment (start 184.6 88.18) (end 184.6 92.5) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBC)) + (segment (start 169.9 89.95) (end 169.9 88.88) (width 0.25) (layer F.Cu) (net 21) (tstamp 5F754BBD)) + (segment (start 183.624999 93.475001) (end 170.624999 93.475001) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBE)) + (segment (start 170.624999 93.475001) (end 169.9 92.750002) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBF)) + (segment (start 169.9 92.750002) (end 169.9 89.95) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BC0)) + (segment (start 169.9 88.88) (end 170.6 88.18) (width 0.25) (layer F.Cu) (net 21) (tstamp 5F754BC1)) + (via (at 169.9 89.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 21) (tstamp 5F754BC7)) + (segment (start 169.725 87.305) (end 170.6 88.18) (width 0.25) (layer F.Cu) (net 21)) + (segment (start 169.725 85.2) (end 169.725 87.305) (width 0.25) (layer F.Cu) (net 21)) + (via (at 169.75 86.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 21)) + (segment (start 169.725 85.2) (end 169.725 86.625) (width 0.25) (layer B.Cu) (net 21)) + (segment (start 169.725 86.625) (end 169.75 86.65) (width 0.25) (layer B.Cu) (net 21)) + (segment (start 188.5 91.88) (end 189.7 93.08) (width 0.25) (layer F.Cu) (net 22)) + (via (at 188.5 91.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 22)) + (segment (start 188.5 90.55) (end 188.5 91.75) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 188.5 91.75) (end 188.5 91.88) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 188.5 90.55) (end 188.5 91.75) (width 0.25) (layer B.Cu) (net 22)) + (via (at 201.797467 97.158879) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 22)) + (segment (start 203.7 95.256346) (end 201.797467 97.158879) (width 0.25) (layer B.Cu) (net 22)) + (segment (start 201.06537 98.6) (end 201.797467 97.867903) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 189.7 93.13) (end 189.7 94.5135) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 201.797467 97.867903) (end 201.797467 97.158879) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 193.7865 98.6) (end 201.06537 98.6) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 203.7 93.08) (end 203.7 95.256346) (width 0.25) (layer B.Cu) (net 22)) + (segment (start 189.75 93.08) (end 189.7 93.13) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 189.7 94.5135) (end 193.7865 98.6) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 222.7 93.08) (end 222.83 93.08) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 222.83 93.08) (end 223.5 93.75) (width 0.25) (layer B.Cu) (net 23)) + (via (at 209.75 97.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 23)) + (segment (start 221.002001 98.275001) (end 210.525001 98.275001) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 210.525001 98.275001) (end 209.75 97.5) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 222.7 93.08) (end 222.7 96.577002) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 222.7 96.577002) (end 221.002001 98.275001) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 208.7 96.45) (end 208.7 93.08) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 209.75 97.5) (end 208.7 96.45) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 208.7 93.08) (end 208.7 91.7) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 208.7 91.7) (end 207.75 90.75) (width 0.25) (layer F.Cu) (net 23)) + (via (at 207.75 89.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 23)) + (segment (start 207.75 88.05) (end 207.75 89.25) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 207.75 90.75) (end 207.75 89.25) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 207.75 89.25) (end 207.75 88.05) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 127.5 114) (end 126.524999 114.975001) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBB)) + (segment (start 127.5 109.68) (end 127.5 114) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBC)) + (segment (start 112.8 111.45) (end 112.8 110.38) (width 0.25) (layer F.Cu) (net 24) (tstamp 5F754BBD)) + (segment (start 126.524999 114.975001) (end 113.524999 114.975001) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBE)) + (segment (start 113.524999 114.975001) (end 112.8 114.250002) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBF)) + (segment (start 112.8 114.250002) (end 112.8 111.45) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BC0)) + (segment (start 112.8 110.38) (end 113.5 109.68) (width 0.25) (layer F.Cu) (net 24) (tstamp 5F754BC1)) + (via (at 112.8 111.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 24) (tstamp 5F754BC7)) + (segment (start 112.8 105.325) (end 112 104.525) (width 0.25) (layer B.Cu) (net 24)) + (segment (start 112.8 111.45) (end 112.8 105.325) (width 0.25) (layer B.Cu) (net 24)) + (via (at 112 103.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 24)) + (segment (start 112 104.525) (end 112 103.25) (width 0.25) (layer B.Cu) (net 24)) + (segment (start 112 103.25) (end 112 104.525) (width 0.25) (layer F.Cu) (net 24)) + (segment (start 146.5 111.5) (end 145.524999 112.475001) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBB)) + (segment (start 146.5 107.18) (end 146.5 111.5) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBC)) + (segment (start 131.8 108.95) (end 131.8 107.88) (width 0.25) (layer F.Cu) (net 25) (tstamp 5F754BBD)) + (segment (start 145.524999 112.475001) (end 132.524999 112.475001) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBE)) + (segment (start 132.524999 112.475001) (end 131.8 111.750002) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBF)) + (segment (start 131.8 111.750002) (end 131.8 108.95) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BC0)) + (segment (start 131.8 107.88) (end 132.5 107.18) (width 0.25) (layer F.Cu) (net 25) (tstamp 5F754BC1)) + (via (at 131.8 108.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 25) (tstamp 5F754BC7)) + (segment (start 131.8 105.75) (end 131 104.95) (width 0.25) (layer B.Cu) (net 25)) + (segment (start 131.8 108.95) (end 131.8 105.65) (width 0.25) (layer B.Cu) (net 25)) + (segment (start 131 105.78) (end 132.5 107.28) (width 0.25) (layer F.Cu) (net 25)) + (segment (start 131 104.95) (end 131 105.78) (width 0.25) (layer F.Cu) (net 25)) + (segment (start 165.6 109.09) (end 164.624999 110.065001) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBB)) + (segment (start 165.6 104.77) (end 165.6 109.09) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBC)) + (segment (start 150.9 106.54) (end 150.9 105.47) (width 0.25) (layer F.Cu) (net 26) (tstamp 5F754BBD)) + (segment (start 164.624999 110.065001) (end 151.624999 110.065001) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBE)) + (segment (start 151.624999 110.065001) (end 150.9 109.340002) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBF)) + (segment (start 150.9 109.340002) (end 150.9 106.54) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BC0)) + (segment (start 150.9 105.47) (end 151.6 104.77) (width 0.25) (layer F.Cu) (net 26) (tstamp 5F754BC1)) + (via (at 150.9 106.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 26) (tstamp 5F754BC7)) + (segment (start 150.9 101.24) (end 150 100.34) (width 0.25) (layer B.Cu) (net 26)) + (segment (start 150.9 106.54) (end 150.9 101.24) (width 0.25) (layer B.Cu) (net 26)) + (segment (start 151.6 101.94) (end 150 100.34) (width 0.25) (layer F.Cu) (net 26)) + (segment (start 151.6 104.77) (end 151.6 101.94) (width 0.25) (layer F.Cu) (net 26)) + (segment (start 169.9 109.05) (end 169.9 107.98) (width 0.25) (layer F.Cu) (net 27) (tstamp 5F754BBD)) + (segment (start 169.9 107.98) (end 170.6 107.28) (width 0.25) (layer F.Cu) (net 27) (tstamp 5F754BC1)) + (via (at 169.9 109.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 27) (tstamp 5F754BC7)) + (segment (start 169.25 108.4) (end 169.9 109.05) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 169.25 103.925) (end 169.25 108.4) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 170.6 105.275) (end 169.25 103.925) (width 0.25) (layer F.Cu) (net 27)) + (segment (start 170.6 107.28) (end 170.6 105.275) (width 0.25) (layer F.Cu) (net 27)) + (segment (start 184.6 109.05) (end 181.5 112.15) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 169.9 110.522996) (end 169.9 109.05) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 181.5 112.15) (end 172.277004 112.15) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 172.252002 112.124998) (end 171.502002 112.124998) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 171.502002 112.124998) (end 169.9 110.522996) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 172.277004 112.15) (end 172.252002 112.124998) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 184.6 107.28) (end 184.6 109.05) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 189 113.85) (end 189 112.78) (width 0.25) (layer F.Cu) (net 28) (tstamp 5F754BBD)) + (segment (start 189 112.78) (end 189.7 112.08) (width 0.25) (layer F.Cu) (net 28) (tstamp 5F754BC1)) + (via (at 189 113.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 28) (tstamp 5F754BC7)) + (segment (start 188.5 110.88) (end 189.7 112.08) (width 0.25) (layer F.Cu) (net 28)) + (segment (start 188.5 108.525) (end 188.5 110.88) (width 0.25) (layer F.Cu) (net 28)) + (segment (start 189 115.25) (end 189 113.85) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 191.784 118.034) (end 189 115.25) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 200.6725 118.034) (end 191.784 118.034) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 203.7 112.08) (end 203.7 115.0065) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 203.7 115.0065) (end 200.6725 118.034) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 188.5315 108.5565) (end 188.5 108.525) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 189 113.85) (end 188.5315 113.3815) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 188.5315 113.3815) (end 188.5315 108.5565) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 208.05 113.85) (end 208.05 112.78) (width 0.25) (layer F.Cu) (net 29) (tstamp 5F754BBD)) + (segment (start 208.05 112.78) (end 208.75 112.08) (width 0.25) (layer F.Cu) (net 29) (tstamp 5F754BC1)) + (via (at 208.05 113.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 29) (tstamp 5F754BC7)) + (segment (start 223.6 111.23) (end 222.75 112.08) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 210.252002 117.02501) (end 209.465472 117.02501) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 222.75 115.25) (end 221 117) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 221 117) (end 210.277012 117) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 210.277012 117) (end 210.252002 117.02501) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208.05 115.609538) (end 208.05 113.85) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 222.75 112.08) (end 222.75 115.25) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 209.465472 117.02501) (end 208.05 115.609538) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208.2 106.95) (end 207.85 106.95) (width 0.25) (layer F.Cu) (net 29)) + (segment (start 207.85 106.95) (end 208 107.1) (width 0.25) (layer F.Cu) (net 29)) + (via (at 208 108.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 29)) + (segment (start 208 107.1) (end 208 108.6) (width 0.25) (layer F.Cu) (net 29)) + (segment (start 208 107.15) (end 208.2 106.95) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208 108.6) (end 208 107.15) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208 113.8) (end 208.05 113.85) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208 108.6) (end 208 113.8) (width 0.25) (layer B.Cu) (net 29)) + (via (at 98.687 139.889) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 30)) + (segment (start 97.975654 140.600346) (end 98.687 139.889) (width 0.25) (layer B.Cu) (net 30)) + (segment (start 97.975654 140.752178) (end 97.975654 140.600346) (width 0.25) (layer B.Cu) (net 30)) + (segment (start 95.44641 127.72559) (end 96.086 127.086) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 91.877886 127.72559) (end 95.44641 127.72559) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 90.975654 128.627822) (end 91.877886 127.72559) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 96.086 127.086) (end 96.914 127.086) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 96.914 127.086) (end 99 125) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 101.175 125) (end 102.575 123.6) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 99 125) (end 101.175 125) (width 0.25) (layer F.Cu) (net 30)) + (via (at 101.175 125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 30)) + (segment (start 102.575 123.6) (end 101.175 125) (width 0.25) (layer B.Cu) (net 30)) + (segment (start 99.047411 139.889) (end 98.687 139.889) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 95 136) (end 101 136) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 101 136) (end 101 137.936411) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 94.334999 135.334999) (end 95 136) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 94.334999 132.229999) (end 94.334999 135.334999) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 95.635001 127.536999) (end 95.635001 130.929997) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 95.635001 130.929997) (end 94.334999 132.229999) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 101 137.936411) (end 99.047411 139.889) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 96.086 127.086) (end 95.635001 127.536999) (width 0.25) (layer F.Cu) (net 30)) + (via (at 122.75 135) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 31)) + (segment (start 125.029234 129.080355) (end 125.029234 132.720766) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 125.029234 132.720766) (end 122.75 135) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 114.591755 135.789305) (end 111.506272 132.703822) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 121.960695 135.789305) (end 114.591755 135.789305) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 122.75 135) (end 121.960695 135.789305) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.595198 120.6248) (end 112.1998 120.6248) (width 0.25) (layer F.Cu) (net 31)) + (via (at 110.984999 121.234999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 31)) + (segment (start 112.1998 120.6248) (end 111.595198 120.6248) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 111.595198 120.6248) (end 110.984999 121.234999) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 110.984999 121.234999) (end 111.595198 120.6248) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.506272 132.703822) (end 111.506272 131.668546) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.506272 131.668546) (end 108.474998 128.637272) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.474998 124.952002) (end 108.074998 124.552002) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.074998 124.552002) (end 108.074998 123.828319) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 110.668318 121.234999) (end 110.984999 121.234999) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.474998 128.637272) (end 108.474998 124.952002) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.074998 123.828319) (end 110.668318 121.234999) (width 0.25) (layer F.Cu) (net 31)) + (via (at 141.108 131.259) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 32)) + (segment (start 142.771 131.259) (end 141.108 131.259) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 146.5 126.28) (end 146.5 127.53) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 146.5 127.53) (end 142.771 131.259) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 132.5 126.28) (end 132.4122 126.28) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 136.254401 131.284401) (end 132.5 127.53) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 141.108 131.259) (end 141.082599 131.284401) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 141.082599 131.284401) (end 136.254401 131.284401) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 132.5 127.53) (end 132.5 126.28) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 132.5 126.28) (end 131.955 126.28) (width 0.25) (layer F.Cu) (net 32)) + (via (at 129 124.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 32)) + (segment (start 127.55 124.2) (end 129 124.2) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 129.875 124.2) (end 130.1375 124.4625) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 129 124.2) (end 129.875 124.2) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 131.955 126.28) (end 130.1375 124.4625) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 129 124.2) (end 127.55 124.2) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 107.42 48.85) (end 106.224255 50.045745) (width 0.5) (layer F.Cu) (net 33) (status 10)) + (segment (start 93.42456 50.1) (end 93.478815 50.045745) (width 0.5) (layer F.Cu) (net 33) (status 30)) + (via (at 100.400008 68.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 100.399628 68.79962) (end 100.400008 68.8) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 99.2 68.79962) (end 100.399628 68.79962) (width 0.5) (layer B.Cu) (net 33) (status 10)) + (segment (start 100.400388 68.79962) (end 100.400008 68.8) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.4 50.045745) (end 93.478815 50.045745) (width 0.5) (layer F.Cu) (net 33) (status 20)) + (segment (start 106.224255 50.045745) (end 100.4 50.045745) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 98.09999 89.29999) (end 98.3 89.5) (width 0.5) (layer F.Cu) (net 33) (status 30)) + (segment (start 100.400008 50.045753) (end 100.4 50.045745) (width 0.5) (layer B.Cu) (net 33)) + (via (at 100.4 50.045745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 100.400008 68.8) (end 100.400008 50.045753) (width 0.5) (layer B.Cu) (net 33) (tstamp 5C028D9F)) + (segment (start 100.400008 68.8) (end 100.5 68.899992) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 97.477817 78.061965) (end 96.4871 78.061965) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 96.4871 78.061965) (end 95.499272 78.061965) (width 0.5) (layer F.Cu) (net 33) (status 20)) + (segment (start 100.400008 75.139774) (end 97.477817 78.061965) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.400008 68.8) (end 100.400008 75.139774) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 97.9 83.55) (end 98.3 83.55) (width 0.5) (layer B.Cu) (net 33) (status 30)) + (segment (start 95.499272 81.149272) (end 97.9 83.55) (width 0.5) (layer B.Cu) (net 33) (status 20)) + (segment (start 95.499272 78.061965) (end 95.499272 81.149272) (width 0.5) (layer B.Cu) (net 33) (status 10)) + (segment (start 98.09999 89.29999) (end 98.3 89.5) (width 0.5) (layer B.Cu) (net 33) (status 30)) + (segment (start 107.5 80.7) (end 107.9 81.1) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156 37.54) (end 156 38.425) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156 38.425) (end 156.2 38.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206.225 85.875) (end 206.175 85.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 85.925) (end 206.175 86.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 66.675) (end 206.175 67.175) (width 0.5) (layer B.Cu) (net 33)) + (via (at 211.625 104.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 211.625 104.875) (end 213.35 104.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 116 44.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 116.875 45.375) (end 118.1 45.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116 44.5) (end 116.875 45.375) (width 0.5) (layer B.Cu) (net 33)) + (via (at 110.25 48) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 109.416256 48.833744) (end 110.25 48) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 107.42 48.85) (end 107.436256 48.833744) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 107.436256 48.833744) (end 109.416256 48.833744) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 113.75 44.5) (end 116 44.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.2 38.625) (end 155.665 38.625) (width 0.5) (layer F.Cu) (net 33)) + (via (at 193.0125 44.7375) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 153.75 96.29) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 153.75 96.502002) (end 153.75 96.29) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 97.565) (end 154.812998 97.565) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.812998 97.565) (end 153.75 96.502002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.225 95.815) (end 156.2 95.815) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 153.75 96.29) (end 154.225 95.815) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.849999 99.749999) (end 173 99.9) (width 0.5) (layer F.Cu) (net 33)) + (via (at 173 99.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 172.849999 98.837999) (end 172.849999 99.749999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 98.325) (end 173.362998 98.325) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.362998 98.325) (end 172.849999 98.837999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.025 99.9) (end 175.2 100.075) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173 99.9) (end 175.025 99.9) (width 0.5) (layer B.Cu) (net 33)) + (via (at 210.875 85.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 213.3 84.125) (end 211.912998 84.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.912998 84.125) (end 210.875 85.162998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 210.875 85.875) (end 206.225 85.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.3 85.875) (end 210.875 85.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 210.875 85.162998) (end 210.875 85.875) (width 0.5) (layer F.Cu) (net 33)) + (via (at 135.325 60.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 137.1 60.125) (end 135.325 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 130.414999 84.349999) (end 130 84.764998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 79.125) (end 133.075 82.187002) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 82.287002) (end 131.012003 84.349999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 131.012003 84.349999) (end 130.414999 84.349999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 130 84.764998) (end 130 93.607998) (width 0.5) (layer F.Cu) (net 33)) + (via (at 167.75 38.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.75 54.69) (end 167.75 56.677998) (width 0.5) (layer B.Cu) (net 33)) + (via (at 173.475 61.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 175.2 61.875) (end 173.475 61.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 167.325 78.115) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 175.2 79.225) (end 173.675 79.225) (width 0.5) (layer F.Cu) (net 33)) + (via (at 162.25 53.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 160.7 52.915) (end 161.375 52.915) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 161.375 52.915) (end 162.25 53.79) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 161.375 54.665) (end 160.7 54.665) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 162.25 53.79) (end 161.375 54.665) (width 0.5) (layer B.Cu) (net 33)) + (via (at 135.5 40.57501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 137.1 41.025) (end 136.65001 40.57501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 136.65001 40.57501) (end 135.5 40.57501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 104.5 79) (end 106.2 80.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 104.5 76.5) (end 104.5 79) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.400008 75.139774) (end 101.760234 76.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.760234 76.5) (end 104.5 76.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 106.6 81.1) (end 106.2 80.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 107.9 81.1) (end 106.6 81.1) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 167.325 78.115) (end 167.325 91.715) (width 0.5) (layer B.Cu) (net 33)) + (via (at 167.325 91.715) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.325 91.715) (end 166.42499 92.61501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 166.42499 97.42499) (end 171.33699 97.42499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 166.42499 92.61501) (end 166.42499 96.21499) (width 0.5) (layer F.Cu) (net 33)) + (via (at 166.42499 98.71499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 166.42499 96.21499) (end 166.42499 98.71499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 166.42499 98.71499) (end 166.42499 111.86501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 162.25 53.79) (end 167.75 53.79) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.75 38.44) (end 167.75 53.69) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.75 53.69) (end 167.75 54.69) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.3 64.925) (end 212.824996 64.925) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.2375 44.7375) (end 194.3 44.8) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.0125 44.7375) (end 194.2375 44.7375) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 44.8) (end 194.3 46.025) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.185 40.39) (end 156.2 40.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.15 101.825) (end 116.15 100.4) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 117.075 99.7) (end 116.85 99.7) (width 0.5) (layer F.Cu) (net 33)) + (via (at 116.85 99.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 118.1 100.725) (end 117.075 99.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 102.475) (end 116.8 102.475) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.8 102.475) (end 116.15 101.825) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.15 100.4) (end 116.85 99.7) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 104.875) (end 192.975 104.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 192.1 104) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 192.975 104.875) (end 192.1 104) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 103.125) (end 192.825 103.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.1 103.85) (end 192.1 104) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.825 103.125) (end 192.1 103.85) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 137.1 99.975) (end 135.774996 99.975) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135.317159 98.099999) (end 135 98.417158) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.774996 99.975) (end 135 99.200004) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135 98.507998) (end 135 99.200004) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135 98.417158) (end 135 99.200004) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 137.1 98.225) (end 136.974999 98.099999) (width 0.5) (layer F.Cu) (net 33)) + (via (at 135 99.200004) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 136.974999 98.099999) (end 135.317159 98.099999) (width 0.5) (layer F.Cu) (net 33)) + (via (at 134.375 79.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 137.1 79.125) (end 134.375 79.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 79.125) (end 134.375 79.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.375 80.325) (end 134.375 79.125) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 80.875) (end 134.925 80.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.925 80.875) (end 134.375 80.325) (width 0.5) (layer B.Cu) (net 33)) + (via (at 154.300002 77.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.325 78.115) (end 165 80.44) (width 0.5) (layer F.Cu) (net 33)) + (via (at 160.475 80.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 165 80.44) (end 160.475 80.44) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.300002 77.79) (end 154.300002 79.640002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.300002 79.640002) (end 155.3 80.64) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 160.42499 80.49001) (end 160.42499 80.44) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 155.3 80.64) (end 160.275 80.64) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 160.275 80.64) (end 160.42499 80.49001) (width 0.5) (layer B.Cu) (net 33)) + (via (at 173.1 81.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 172.475 80.625) (end 173.1 81.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.475 79.225) (end 172.475 80.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.675 79.225) (end 172.475 79.225) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 174.925 81.25) (end 175.2 80.975) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.1 81.25) (end 174.925 81.25) (width 0.5) (layer B.Cu) (net 33)) + (via (at 192.7 84.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 193.625 85.875) (end 192.706593 84.956593) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 85.875) (end 193.625 85.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 211.65 66.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 213.3 66.675) (end 212.225 66.675) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 212.225 66.675) (end 211.65 66.1) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 212.825 64.925) (end 213.3 64.925) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.65 66.1) (end 212.825 64.925) (width 0.5) (layer F.Cu) (net 33)) + (via (at 206.175 66.675) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.362996 42.775) (end 134.749998 42.162002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.749998 42.162002) (end 134.749998 41.325012) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 42.775) (end 135.362996 42.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.749998 41.325012) (end 135.5 40.57501) (width 0.5) (layer B.Cu) (net 33)) + (via (at 153.8 39.29) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 173.806234 42.08623) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 174.595004 42.875) (end 173.841595 42.121591) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 175.2 42.875) (end 174.595004 42.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.785002 42.064998) (end 173.806234 42.08623) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 83.475) (end 116.425 83.475) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 114.662001 81.712001) (end 116.35 83.4) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.425 83.475) (end 116.35 83.4) (width 0.5) (layer B.Cu) (net 33)) + (via (at 116.35 83.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 107.9 81.1) (end 108.512001 81.712001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 108.512001 81.712001) (end 114.662001 81.712001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 115.625011 82.675011) (end 116.35 83.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.625011 81.893733) (end 115.625011 82.675011) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 81.725) (end 117.980745 81.605745) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.980745 81.605745) (end 115.912999 81.605745) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.912999 81.605745) (end 115.625011 81.893733) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.999998 61.262002) (end 134.999998 60.450002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.999998 60.450002) (end 135.325 60.125) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135.612996 61.875) (end 134.999998 61.262002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 61.875) (end 135.612996 61.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173 61.4) (end 173.475 61.875) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173 60.5) (end 173 61.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 60.125) (end 173.375 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.375 60.125) (end 173 60.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 116.512998 64.475) (end 115.8 63.762002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 118.1 64.475) (end 116.512998 64.475) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.275 58.625) (end 118.3 58.625) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 115.8 59.1) (end 116.275 58.625) (width 0.5) (layer B.Cu) (net 33)) + (via (at 115.8 61.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 118.3 60.375) (end 116.925 60.375) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 116.925 60.375) (end 115.8 61.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.8 63.762002) (end 115.8 61.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 115.8 61.5) (end 115.8 59.1) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 117.025 62.725) (end 115.8 61.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 62.725) (end 117.025 62.725) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.8 61.5) (end 114.7 61.5) (width 0.5) (layer F.Cu) (net 33)) + (via (at 113 59.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 114.7 61.5) (end 113 59.8) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 113 59.8) (end 111.65 58.45) (width 0.5) (layer B.Cu) (net 33)) + (via (at 111.725 46.525) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 111.65 58.45) (end 111.65 46.6) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 110.25 48) (end 111.725 46.525) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 111.65 46.6) (end 111.725 46.525) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 111.725 46.525) (end 113.75 44.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.325 60.125) (end 134.617002 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.2 57.715) (end 154.625 57.715) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.099999 58.240001) (end 154.099999 60.539999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.625 57.715) (end 154.099999 58.240001) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.099999 60.539999) (end 155.1 61.54) (width 0.5) (layer F.Cu) (net 33)) + (via (at 161.65 60.89) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 155.1 61.54) (end 161 61.54) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 161 61.54) (end 161.65 60.89) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 163.637998 60.89) (end 167.75 56.777998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 161.65 60.89) (end 163.637998 60.89) (width 0.5) (layer B.Cu) (net 33)) + (via (at 154.099999 60.539999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 156.2 59.465) (end 155.174998 59.465) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 155.174998 59.465) (end 154.099999 60.539999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 165.825479 36.615479) (end 167.75 38.54) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.474521 36.615479) (end 165.825479 36.615479) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156 37.54) (end 156 37.09) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156 37.09) (end 156.474521 36.615479) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 195.175 62.25) (end 195.3 62.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 195.3 62.125) (end 194.475002 62.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.3 63.925) (end 194.3 64.925) (width 0.5) (layer F.Cu) (net 33)) + (via (at 193.3 63.925) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 197.92499 68.75) (end 198.87499 69.7) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 66.675) (end 194.3 68.75) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 68.75) (end 197.92499 68.75) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.65 66.1) (end 209.85 66.1) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 209.275 66.675) (end 206.175 66.675) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 209.85 66.1) (end 209.275 66.675) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 198.87499 69.7) (end 198.87499 69.7) (width 0.5) (layer B.Cu) (net 33) (tstamp 5F77CAAB)) + (via (at 198.87499 69.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 200.95 69.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 206.1 69.7) (end 206.175 69.625) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 67.175) (end 206.175 68.125) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 200.95 69.7) (end 206.1 69.7) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 68.125) (end 206.175 85.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 168.946 39.636) (end 168.946 39.65) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 135.225 60.125) (end 135.325 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.569998 63.4) (end 131.95 63.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 132.652 79.225) (end 129.45 76.023) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.849999 64.119999) (end 129.569998 63.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.849999 68.462001) (end 128.849999 64.119999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 79.225) (end 132.652 79.225) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.45 76.023) (end 129.45 69.062002) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 131.95 63.4) (end 135.225 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.45 69.062002) (end 128.849999 68.462001) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 187.25 119.445) (end 189.1 119.445) (width 0.25) (layer F.Cu) (net 33)) + (via (at 189.95 118.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 189.1 119.445) (end 189.895 118.65) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 189.895 118.65) (end 189.95 118.65) (width 0.25) (layer F.Cu) (net 33)) + (via (at 98.9664 127.6462) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 104.5036 128.3144) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 189.95 119.745) (end 189.95 118.65) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 188.5 121.195) (end 189.95 119.745) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 187.25 121.195) (end 188.5 121.195) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 175.2 119.175) (end 173.618 119.175) (width 0.25) (layer B.Cu) (net 33)) + (via (at 172.7818 117.399) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 173.618 119.175) (end 172.7818 118.3388) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 172.7818 118.3388) (end 172.7818 117.399) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 175.174 117.399) (end 175.2 117.425) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 172.7818 117.399) (end 175.174 117.399) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 172.7818 117.399) (end 167.8288 112.446) (width 0.25) (layer F.Cu) (net 33)) + (via (at 167.8034 111.8618) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.8288 112.446) (end 167.8288 111.8872) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 167.8288 111.8872) (end 167.8034 111.8618) (width 0.25) (layer F.Cu) (net 33)) + (via (at 166.42499 111.86501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.8034 111.8618) (end 166.4282 111.8618) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 166.4282 111.8618) (end 166.42499 111.86501) (width 0.25) (layer B.Cu) (net 33)) + (via (at 135.669468 118.748132) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.096599 118.175263) (end 135.669468 118.748132) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 135.096599 117.705799) (end 135.096599 118.175263) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 137.1 117.325) (end 135.477398 117.325) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 135.477398 117.325) (end 135.096599 117.705799) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 136.773132 118.748132) (end 137.1 119.075) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 135.669468 118.748132) (end 136.773132 118.748132) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 151.2836 116.2658) (end 151.2836 117.3876) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.6344 114.915) (end 151.2836 116.2658) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.7972 114.915) (end 152.6344 114.915) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 151.2836 119.1376) (end 153.7274 119.1376) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 154.4084 118.4566) (end 154.4084 117.8724) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 153.7274 119.1376) (end 154.4084 118.4566) (width 0.25) (layer B.Cu) (net 33)) + (via (at 153.2948 114.915) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 154.4084 117.8724) (end 153.2948 116.7588) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 153.2948 116.7588) (end 153.2948 114.915) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 156.2 114.915) (end 153.2948 114.915) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 153.2948 114.915) (end 152.7972 114.915) (width 0.5) (layer F.Cu) (net 33)) + (via (at 128.025 113.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 128 113.25) (end 128.025 113.25) (width 0.25) (layer F.Cu) (net 33)) + (via (at 130.1606 115.4178) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.096599 117.705799) (end 132.8086 115.4178) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 130.443442 115.4178) (end 130.1606 115.4178) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 130.1606 115.3856) (end 130.1606 115.4178) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 132.8086 115.4178) (end 130.443442 115.4178) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 128.025 113.25) (end 130.1606 115.3856) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 153.782 39.272) (end 153.8 39.29) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 153.782 38.75) (end 153.782 39.272) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 171.265 78.115) (end 167.325 78.115) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.475 79.325) (end 171.265 78.115) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.602158 40.375) (end 156.2 40.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.8 39.29) (end 153.8 39.572842) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.8 39.572842) (end 154.602158 40.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 44.45) (end 194.3 44.8) (width 0.5) (layer F.Cu) (net 33)) + (via (at 205.994 44.3738) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 206 44.3798) (end 205.994 44.3738) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 100.42262 68.79962) (end 100.42262 68.822612) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 100.42262 68.79962) (end 100.400388 68.79962) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.7 68.79962) (end 100.42262 68.79962) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128 113.25) (end 125.883 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 172.749999 98.837999) (end 172.849999 98.837999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 171.33699 97.42499) (end 172.749999 98.837999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.808 62.125) (end 192.532 61.849) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 195.3 62.125) (end 192.808 62.125) (width 0.5) (layer F.Cu) (net 33)) + (via (at 192.532 61.849) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 193.3 63.925) (end 192.4685 63.0935) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.4685 61.9125) (end 192.532 61.849) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.4685 63.0935) (end 192.4685 61.9125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 198.87499 69.7) (end 200.95 69.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206.132001 87.999999) (end 206.175 87.957) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 86.925) (end 206.175 87.957) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 87.45) (end 194.849999 87.999999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 85.875) (end 194.3 87.45) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 87.957) (end 206.175 93.832998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.849999 87.999999) (end 206.132001 87.999999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 171.425001 62.889999) (end 171.425001 61.562999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.25 78.04) (end 167.25 65.0965) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 168.8465 63.5) (end 170.815 63.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.325 78.115) (end 167.25 78.04) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.25 65.0965) (end 168.8465 63.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 170.815 63.5) (end 171.425001 62.889999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 171.425001 60.427001) (end 171.425001 61.562999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.7272 56.7438) (end 167.7418 56.7438) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.7418 56.7438) (end 171.425001 60.427001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 171.476 61.875) (end 171.45 61.849) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.475 61.875) (end 171.476 61.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 118.432842 98.4) (end 117.132842 99.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 122.1355 98.4) (end 118.432842 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.132842 99.7) (end 116.85 99.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 122.1355 98.4) (end 124.15 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128 101.9015) (end 128 113.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 124.15 98.4) (end 124.4985 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 124.4985 98.4) (end 128 101.9015) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 136.3326 120.904) (end 135.669468 120.240868) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 135.669468 120.240868) (end 135.669468 118.748132) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 150.241 120.904) (end 136.3326 120.904) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 151.2836 119.1376) (end 151.2836 119.8614) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 151.2836 119.8614) (end 150.241 120.904) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 154.83499 111.86501) (end 166.42499 111.86501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.7972 114.915) (end 152.7972 113.9028) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.7972 113.9028) (end 154.83499 111.86501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.8965 76.815) (end 154.300002 77.411498) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.300002 77.411498) (end 154.300002 77.79) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.2 76.815) (end 154.8965 76.815) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.7 84.6045) (end 192.7 84.95) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 84.125) (end 193.1795 84.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.1795 84.125) (end 192.7 84.6045) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 191.77 45.98) (end 193.0125 44.7375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.405 47.8155) (end 191.77 47.1805) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 191.77 47.1805) (end 191.77 45.98) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 47.775) (end 194.2595 47.8155) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.2595 47.8155) (end 192.405 47.8155) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.532 61.214) (end 192.532 61.849) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 195.3 60.375) (end 193.371 60.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 193.371 60.375) (end 192.532 61.214) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.0875 66.04) (end 192.0875 65.1375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.0875 65.1375) (end 193.3 63.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 66.675) (end 192.7225 66.675) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.7225 66.675) (end 192.0875 66.04) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 117.5485) (end 156.2 116.665) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 154.4084 118.4566) (end 155.2919 118.4566) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 155.2919 118.4566) (end 156.2 117.5485) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 101.030912 128.134039) (end 100.196873 127.3) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 99.3126 127.3) (end 98.9664 127.6462) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 100.196873 127.3) (end 99.3126 127.3) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 99.515367 129.009039) (end 98.6 128.093672) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 98.6 128.0126) (end 98.9664 127.6462) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 98.6 128.093672) (end 98.6 128.0126) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 101.545613 127.619338) (end 103.719338 127.619338) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 101.030912 128.134039) (end 101.545613 127.619338) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 104.4144 128.3144) (end 104.5036 128.3144) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 103.719338 127.619338) (end 104.4144 128.3144) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 104.5036 128.3144) (end 109.9856 128.3144) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.05 127.25) (end 111.05 125.005) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 109.9856 128.3144) (end 111.05 127.25) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.813828 122.863389) (end 113.631807 122.863389) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 111.422217 123.255) (end 111.813828 122.863389) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 111.05 123.255) (end 111.422217 123.255) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.523025 121.275487) (end 113.523025 120.676975) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.631807 122.863389) (end 113.631807 121.681468) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.631807 121.681468) (end 113.523025 121.275487) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 118.833 115.367) (end 119.667 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.523025 120.676975) (end 118.833 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 125.883 115.367) (end 119.667 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.633499 125.005) (end 114.08474 124.553759) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.05 125.005) (end 113.633499 125.005) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.05 125.005) (end 109.305 125.005) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 109.305 125.005) (end 108.6 124.3) (width 0.25) (layer B.Cu) (net 33)) + (via (at 108.6 124.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 109.284728 123.255) (end 108.6 123.939728) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 108.6 123.939728) (end 108.6 124.3) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 111.05 123.255) (end 109.284728 123.255) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 130 93.607998) (end 131.607998 93.607998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135 97) (end 135 98.607998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 131.607998 93.607998) (end 135 97) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.617002 56.867002) (end 129.25 51.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.25 51.5) (end 129.25 49.837998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 127.5 41.5) (end 127.6 41.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.25 49.837998) (end 127.5 48.087998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.617002 60.225) (end 134.617002 56.867002) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 127.5 48.087998) (end 127.5 41.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206 47.5) (end 206 44.3798) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.820511 58.929489) (end 206 55.75) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206 55.75) (end 206 47.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 68.175) (end 202.820511 64.820511) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.820511 64.820511) (end 202.820511 58.929489) (width 0.5) (layer B.Cu) (net 33)) + (via (at 202.25 100.999998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 202.050001 101.199997) (end 202.25 100.999998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 103.125) (end 194.3 101.657524) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.757527 101.199997) (end 202.050001 101.199997) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 101.657524) (end 194.757527 101.199997) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206.175 93.7006) (end 202.25 97.6256) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.25 97.6256) (end 202.25 100.999998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 124.507998 98.4) (end 124.15 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 130 93.607998) (end 129.3 93.607998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.3 93.607998) (end 124.507998 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.749999 44.249999) (end 116 44.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.749999 43.137999) (end 115.749999 44.249999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 116.087999 42.799999) (end 115.749999 43.137999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.799999) (end 116.087999 42.799999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.799999) (end 118.1 43.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.87501 41.2) (end 135.5 40.57501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.6 41.4) (end 134.67501 41.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.799999) (end 117.274999 42.725001) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.67501 41.4) (end 134.87501 41.2) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.725001) (end 118.6 41.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.300002 78.544502) (end 154.300002 77.79) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 78.565) (end 154.3205 78.565) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.3205 78.565) (end 154.300002 78.544502) (width 0.5) (layer B.Cu) (net 33)) + (via (at 106.624999 82.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 106.624999 81.124999) (end 106.6 81.1) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 106.624999 82.8) (end 106.624999 81.124999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 106.4 83.024999) (end 106.624999 82.8) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.4 87.350002) (end 106.4 83.024999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.575 87.375) (end 106.4 87.2) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.4 87.350002) (end 106.4 87.2) (width 0.25) (layer B.Cu) (net 33)) + (via (at 106.4 87.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 107.95 87.375) (end 106.575 87.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.4 85.925) (end 106.4 87.2) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 106.7 85.625) (end 106.4 85.925) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 107.95 85.625) (end 106.7 85.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 213.3 47.775) (end 212.939998 47.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.3 47.775) (end 213.025 47.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.4 46.025) (end 211.775 46.025) (width 0.5) (layer F.Cu) (net 33)) + (via (at 211.4 46.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 211.775 46.025) (end 211.4 46.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 213.4 47.775) (end 211.775 47.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.349999 47.349999) (end 211.349999 46.450001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.349999 46.450001) (end 211.4 46.4) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.775 47.775) (end 211.349999 47.349999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 165.59998 99.54) (end 166.42499 98.71499) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.595 99.54) (end 165.59998 99.54) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 97.565) (end 156.2 99.145) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 99.145) (end 156.595 99.54) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 205.75 113.909) (end 205.75 105) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 189.95 118.65) (end 201.009 118.65) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 201.009 118.65) (end 205.75 113.909) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.25 101.45) (end 202.25 100.999998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.625 104.875) (end 205.675 104.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 205.675 104.875) (end 202.25 101.45) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.6 103.5) (end 211.6 104.85) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 213.35 103.125) (end 211.975 103.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.6 104.85) (end 211.625 104.875) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.975 103.125) (end 211.6 103.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 98.3 84.453) (end 98.09999 84.65301) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.3 83.55) (end 98.3 84.453) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.09999 88.288481) (end 98.09999 84.65301) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.3 88.488491) (end 98.09999 88.288481) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.3 89.5) (end 98.3 88.488491) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135.5 40.57501) (end 137.32501 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 137.32501 38.75) (end 139.588 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 139.334 38.75) (end 139.588 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 139.588 38.75) (end 156 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 174.767464 41.125) (end 175.2 41.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.806234 42.08623) (end 174.767464 41.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 187.739 39.464) (end 187.525 39.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.0125 44.7375) (end 187.739 39.464) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.707525 39.249999) (end 187.524999 39.249999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.319314 39.63821) (end 175.707525 39.249999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 187.524999 39.249999) (end 187.739 39.464) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 167.75 38.44) (end 168.94821 39.63821) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 168.94821 39.63821) (end 175.319314 39.63821) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 39.757524) (end 175.319314 39.63821) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 41.125) (end 175.2 39.757524) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 209.7738 44.3738) (end 211.4 46) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.4 46) (end 211.4 46.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 205.994 44.3738) (end 209.7738 44.3738) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.62501 44.12499) (end 194.3 44.45) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 205.74519 44.12499) (end 194.62501 44.12499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 205.994 44.3738) (end 205.74519 44.12499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 218.1 47.775) (end 218.475 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.325 46.25) (end 218.1 46.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.1 47.775) (end 218.125012 47.800012) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.1 47.775) (end 218.3916 47.775) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 218.1 46.025) (end 218.4148 46.025) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 92.18 46.26456) (end 93.478815 44.965745) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 92.18 46.31) (end 92.18 46.26456) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 91.67 45.8) (end 92.18 46.31) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 106.224255 44.965745) (end 107.42 43.77) (width 0.5) (layer F.Cu) (net 34) (status 20)) + (segment (start 106.876238 47.6) (end 108.7 47.6) (width 0.5) (layer F.Cu) (net 34) (status 20)) + (segment (start 105.676238 48.8) (end 106.876238 47.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 92.18 48.85) (end 92.23 48.8) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (via (at 96.7 67.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 96.7 68.79962) (end 96.7 67.8) (width 0.5) (layer B.Cu) (net 34) (status 10)) + (segment (start 97.474956 67.025044) (end 103.225042 67.025044) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.3 68.100002) (end 104.3 68.79962) (width 0.5) (layer F.Cu) (net 34) (status 20)) + (segment (start 96.7 67.8) (end 97.474956 67.025044) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.225042 67.025044) (end 104.3 68.100002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 96.9 51.552002) (end 96.9 48.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 96.7 67.8) (end 96.9 67.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 96.9 67.6) (end 96.9 51.552002) (width 0.5) (layer B.Cu) (net 34)) + (via (at 96.9 48.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 92.23 48.8) (end 96.9 48.8) (width 0.5) (layer F.Cu) (net 34) (status 10)) + (via (at 96.9 44.965745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 96.9 48.8) (end 96.9 44.965745) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 93.478815 44.965745) (end 96.9 44.965745) (width 0.5) (layer F.Cu) (net 34) (status 10)) + (segment (start 96.9 44.965745) (end 106.224255 44.965745) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.676238 48.8) (end 96.9 48.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.3 68.79962) (end 104.998242 68.79962) (width 0.5) (layer F.Cu) (net 34) (status 10)) + (segment (start 94.3 78.55) (end 94.3 83.55) (width 0.5) (layer B.Cu) (net 34) (status 20)) + (segment (start 90 74.25) (end 94.3 78.55) (width 0.5) (layer B.Cu) (net 34) (status 10)) + (segment (start 94.3 84.9) (end 94.3 89.5) (width 0.5) (layer B.Cu) (net 34) (status 20)) + (segment (start 94.3 83.55) (end 94.3 84.9) (width 0.5) (layer B.Cu) (net 34) (status 10)) + (segment (start 94.3 89.5) (end 93.538491 89.5) (width 0.5) (layer B.Cu) (net 34) (status 30)) + (segment (start 92.18 48.85) (end 92.18 46.31) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 108.718815 47.505745) (end 108.718815 50.045745) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 91.500001 103.500001) (end 92.5 104.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 91.049999 103.049999) (end 91.500001 103.500001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 94.3 98.053998) (end 93.176999 99.176999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 91.049999 101.303999) (end 91.049999 103.049999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 94.3 89.5) (end 94.3 98.053998) (width 0.5) (layer B.Cu) (net 34)) + (via (at 106.7 74.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 93.176999 99.176999) (end 91.049999 101.303999) (width 0.5) (layer B.Cu) (net 34) (tstamp 5D905040)) + (via (at 93.176999 99.176999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 107.6 76.3) (end 107.9 76) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.7 70.501378) (end 106.7 74.7) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.998242 68.79962) (end 106.7 70.501378) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 106.7 74.8) (end 107.9 76) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 106.7 74.7) (end 106.7 74.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.7 60.375) (end 122.625 60.375) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.7 62.125) (end 199.375 62.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 95.5 71.438176) (end 95.5 69.05311) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 95.5 69.05311) (end 95.6285 68.92461) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 94.738177 72.199999) (end 95.5 71.438176) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 90 74.25) (end 92.050001 72.199999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 92.050001 72.199999) (end 94.738177 72.199999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 96.57501 68.92461) (end 96.7 68.79962) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 95.6285 68.92461) (end 96.57501 68.92461) (width 0.5) (layer B.Cu) (net 34)) + (via (at 148.5 95.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 95.4) (end 149 95.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 142.125 40.8) (end 141.9 41.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.425 60.225) (end 148.5 60.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 160.000011 73.750011) (end 148.749989 73.750011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 79.65) (end 148.5 73.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.749989 73.650011) (end 148.5 73.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 73.9) (end 148.5 64.7) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 57.65) (end 148.5 53.9) (width 0.5) (layer B.Cu) (net 34)) + (via (at 124.5 44.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 144 40.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 144 40.8) (end 142.125 40.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 40.9) (end 144 40.9) (width 0.5) (layer B.Cu) (net 34)) + (via (at 153.625 52.915) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 156.3 54.665) (end 154.412998 54.665) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 156.3 52.915) (end 153.625 52.915) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 154.412998 54.665) (end 153.625 53.877002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 153.625 53.877002) (end 153.625 52.915) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 146 113.9) (end 147.15 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 59.949999) (end 186.025 60.125) (width 0.5) (layer B.Cu) (net 34)) + (via (at 182 79.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 200.75 85.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 199.225 85.75) (end 199.1 85.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 200.75 85.75) (end 199.225 85.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 186.924999 105.574999) (end 182.75 101.4) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.562001 98.249999) (end 180.075001 98.249999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180.075001 98.249999) (end 180 98.325) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.75 101.4) (end 182.75 99.437998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 113.574999) (end 186.924999 110.225001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 106.574999) (end 186.924999 105.574999) (width 0.5) (layer B.Cu) (net 34)) + (via (at 144.175 60.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 141.9 60.125) (end 144.175 60.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144.175 60.225) (end 148.425 60.225) (width 0.5) (layer B.Cu) (net 34)) + (via (at 181.975 60.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.025 60.125) (end 181.975 60.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.975 60.125) (end 180 60.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 62.725) (end 123.475 62.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 123.175 82) (end 122.9 81.725) (width 0.5) (layer B.Cu) (net 34)) + (via (at 111.75 88.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 111.75 88.5) (end 109.075 88.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 57.9) (end 148.5 57.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 60.15) (end 148.5 57.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 79.65) (end 148.5 91.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 67.499998) (end 186.5 72.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 59.949999) (end 186.5 60.249998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 60.249998) (end 186.5 67.499998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.2 59.949998) (end 186.200001 59.949999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 45.350001) (end 186.2 45.350002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.2 45.350002) (end 186.2 59.949998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144 41.95) (end 144 40.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 42.775) (end 143.175 42.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 143.175 42.775) (end 144 41.95) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 142.6 113.9) (end 146 113.9) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F76BAE9)) + (segment (start 186.5 72.15) (end 186.5 79.65) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F76BAED)) + (segment (start 124.675 100.725) (end 125.45 101.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 100.725) (end 124.675 100.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.149999 107.199999) (end 125.45 101.5) (width 0.5) (layer B.Cu) (net 34)) + (via (at 125.45 101.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 124.762001 102.550001) (end 125.45 101.862002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.45 101.862002) (end 125.45 101.5) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.9 102.475) (end 122.975001 102.550001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.975001 102.550001) (end 124.762001 102.550001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.175 104.875) (end 220.175021 104.874979) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.15 104.875) (end 220.175 104.875) (width 0.5) (layer F.Cu) (net 34)) + (via (at 220.175021 104.874979) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.924999 106.574999) (end 186.95 106.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 100.924999) (end 192.374999 100.924999) (width 0.5) (layer B.Cu) (net 34)) + (via (at 192.374999 100.924999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 192.374999 100.924999) (end 192.899998 100.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 192.899998 100.4) (end 200.1 100.4) (width 0.5) (layer F.Cu) (net 34)) + (via (at 200.1 100.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 200.1 102.125) (end 199.1 103.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 200.1 100.4) (end 200.1 102.125) (width 0.5) (layer B.Cu) (net 34)) + (via (at 201.5 104.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 201.062001 103.099999) (end 201.5 103.537998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.5 103.537998) (end 201.5 104.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.1 103.125) (end 199.125001 103.099999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.125001 103.099999) (end 201.062001 103.099999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 200.875 104.875) (end 199.1 104.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.5 104.25) (end 200.875 104.875) (width 0.5) (layer F.Cu) (net 34)) + (via (at 182.381001 99.068999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 181.375 100.075) (end 182.381001 99.068999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 100.075) (end 181.375 100.075) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.75 99.437998) (end 182.381001 99.068999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.381001 99.068999) (end 181.562001 98.249999) (width 0.5) (layer B.Cu) (net 34)) + (via (at 162.7 96.49) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 162.025 95.815) (end 162.7 96.49) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 95.815) (end 162.025 95.815) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161.625 97.565) (end 162.7 96.49) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 97.565) (end 161.625 97.565) (width 0.5) (layer F.Cu) (net 34)) + (via (at 144.9 98.900004) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 141.9 98.225) (end 144.224996 98.225) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 143.825004 99.975) (end 144.9 98.900004) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.9 98.9) (end 144.9 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144.224996 98.225) (end 144.9 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 99.975) (end 143.825004 99.975) (width 0.5) (layer F.Cu) (net 34)) + (via (at 144.95 79.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 144.925 79.125) (end 144.95 79.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 79.65) (end 148.1 79.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.1 79.25) (end 144.95 79.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 79.125) (end 144.925 79.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 80.875) (end 144.425 80.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.95 80.35) (end 144.95 79.15) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.425 80.875) (end 144.95 80.35) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.775 76.815) (end 163.2 77.24) (width 0.5) (layer B.Cu) (net 34)) + (via (at 163.2 77.24) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 161 76.815) (end 162.775 76.815) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.2 77.665) (end 163.2 77.24) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.3 78.565) (end 163.2 77.665) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 78.565) (end 162.3 78.565) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.300001 80.612001) (end 182.300001 79.950001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 181.575 79.225) (end 180 79.225) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.937002 80.975) (end 182.300001 80.612001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182 79.65) (end 181.575 79.225) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.300001 79.950001) (end 182 79.65) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 80.975) (end 181.937002 80.975) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 84.125) (end 199.225001 83.999999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.225001 83.999999) (end 201.162001 83.999999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.500001 84.337999) (end 201.500001 84.999999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.500001 84.999999) (end 200.75 85.75) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.162001 83.999999) (end 201.500001 84.337999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.1 82.05) (end 199.1 84.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 198.3 81.25) (end 199.1 82.05) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 79.75) (end 188 81.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 188 81.25) (end 198.3 81.25) (width 0.5) (layer B.Cu) (net 34)) + (via (at 212.5 81) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 216.85 81) (end 212.5 81) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.587002 85.875) (end 220.562002 84.9) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.1 85.875) (end 219.587002 85.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.562002 84.9) (end 220.562002 83.212002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.1 84.125) (end 219.025 83.2) (width 0.5) (layer B.Cu) (net 34)) + (via (at 220.562002 83.212002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 219.025 83.2) (end 220.55 83.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.55 83.2) (end 220.562002 83.212002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.562002 83.212002) (end 220.562002 82.662002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.9 81) (end 217 81) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.562002 82.662002) (end 218.9 81) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.175 66.675) (end 220.2 66.65) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.223789 64.801211) (end 219.584053 64.801211) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.2 65.417158) (end 220.2 66.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.584053 64.801211) (end 220.2 65.417158) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.1 64.925) (end 218.223789 64.801211) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.1 66.675) (end 220.175 66.675) (width 0.5) (layer F.Cu) (net 34)) + (via (at 220.2 66.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 124.2 43.625) (end 124.5 43.925) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 43.625) (end 124.2 43.625) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.5 43.925) (end 124.5 44.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.5 44.25) (end 124.5 44.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 123.925 45.375) (end 122.9 45.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.5 44.8) (end 123.925 45.375) (width 0.5) (layer F.Cu) (net 34)) + (via (at 117.15 47.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 123 46.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 123 45.475) (end 122.9 45.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 123 46.95) (end 123 45.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.65 47.3) (end 123 46.95) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 117.15 47.1) (end 117.35 47.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 117.35 47.3) (end 122.65 47.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 38.625) (end 162.685 38.625) (width 0.5) (layer B.Cu) (net 34)) + (via (at 163.85 39.89) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 162.685 38.625) (end 163.85 39.79) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.85 39.79) (end 163.85 39.89) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.365 40.375) (end 161 40.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 163.85 39.89) (end 163.365 40.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 40.375) (end 161 41.375) (width 0.5) (layer F.Cu) (net 34)) + (via (at 181.7 43.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.200001 45.350001) (end 184.05 43.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 41.125) (end 181.3 41.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.3 41.125) (end 181.7 41.525) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.7 41.525) (end 181.7 43.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.375 42.875) (end 181.7 43.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 42.875) (end 181.375 42.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 184.05 43.2) (end 181.7 43.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.1 46.025) (end 201.525 46.025) (width 0.5) (layer B.Cu) (net 34)) + (via (at 201.75 47.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 201.525 46.025) (end 201.75 46.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.75 46.25) (end 201.75 47.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.125 47.8) (end 199.1 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.75 47.8) (end 199.125 47.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 47.775) (end 199.1 48.825) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 111.75 88.5) (end 114.7 85.55) (width 0.5) (layer F.Cu) (net 34)) + (via (at 123.95 85.55) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 114.7 85.55) (end 117.3198 85.55) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.637002 81.725) (end 126.25 83.337998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 81.725) (end 124.637002 81.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.362002 85.55) (end 123.95 85.55) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.25 83.662002) (end 124.362002 85.55) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.25 83.337998) (end 126.25 83.662002) (width 0.5) (layer B.Cu) (net 34)) + (via (at 215.8 101.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 144.374999 61.337005) (end 144.374999 60.324999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 143.837004 61.875) (end 144.374999 61.337005) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 61.875) (end 143.837004 61.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.374999 60.324999) (end 144.175 60.125) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 61.875) (end 181.787004 61.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.300001 61.362003) (end 182.300001 60.450001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.300001 60.450001) (end 181.975 60.125) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 181.787004 61.875) (end 182.300001 61.362003) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.537002 64.475) (end 122.9 64.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 63.762001) (end 124.537002 64.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.687002 58.625) (end 125.250001 59.187999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.7 58.625) (end 124.687002 58.625) (width 0.5) (layer F.Cu) (net 34)) + (via (at 125.250001 60.399999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 125.225002 60.375) (end 125.250001 60.399999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 125.250001 59.187999) (end 125.250001 60.399999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.7 60.375) (end 125.225002 60.375) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 117.14965 47.09965) (end 117.15 47.1) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 114.34965 47.09965) (end 117.14965 47.09965) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 108.718815 50.045745) (end 111.403555 50.045745) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 111.403555 50.045745) (end 114.34965 47.09965) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 63.300001) (end 125.250001 63.762001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 60.399999) (end 125.250001 63.300001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.95 58.365) (end 162.95 59.590002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 57.715) (end 162.3 57.715) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 162.3 57.715) (end 162.95 58.365) (width 0.5) (layer B.Cu) (net 34)) + (via (at 162.95 59.590002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 161 59.465) (end 162.824998 59.465) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.824998 59.465) (end 162.95 59.590002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 66.675) (end 200.287002 66.675) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 64.925) (end 200.825 64.925) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.300005 65.400005) (end 201.300005 67.199995) (width 0.5) (layer B.Cu) (net 34)) + (via (at 201.056001 67.443999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 200.287002 66.675) (end 201.056001 67.443999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 200.825 64.925) (end 201.300005 65.400005) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.300005 67.199995) (end 201.056001 67.443999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.9 63.85) (end 200.825 64.925) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.7 62.125) (end 201.9 62.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.9 62.125) (end 201.9 63.85) (width 0.5) (layer B.Cu) (net 34)) + (via (at 204.5 52.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 209.45 64.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 209.45 67.5) (end 209.35 67.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 209.45 64.25) (end 209.45 67.5) (width 0.5) (layer B.Cu) (net 34)) + (via (at 209.35 67.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 213.264998 68.75) (end 218.1 68.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.35 67.6) (end 212.114998 67.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 212.114998 67.6) (end 213.264998 68.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 186.924999 110.225001) (end 186.924999 106.574999) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F77CAB5)) + (via (at 186.924999 110.225001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 52.3) (end 148.5 46.1) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F77CAB9)) + (via (at 124.598 80.950008) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 124.637002 80.98901) (end 124.598 80.950008) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.935003 63.300001) (end 127.800001 64.164999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.637002 81.725) (end 124.637002 80.98901) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 127.800001 77.748007) (end 124.598 80.950008) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 63.300001) (end 126.935003 63.300001) (width 0.5) (layer F.Cu) (net 34)) + (via (at 104.6 125.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 185.828198 117.3736) (end 186.924999 116.276799) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 113.674999) (end 186.924999 116.276799) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.992 117.425) (end 183.0434 117.3736) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 117.425) (end 182.992 117.425) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 120.3754) (end 180 119.175) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180.8196 121.195) (end 180 120.3754) (width 0.5) (layer F.Cu) (net 34)) + (via (at 181.200002 117.425) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 181.3022 121.195) (end 180.8196 121.195) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.85 121.195) (end 181.3022 121.195) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 184.4912 119.0538) (end 184.1 119.445) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.4912 117.3736) (end 184.4912 119.0538) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.4912 117.3736) (end 185.828198 117.3736) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.1 119.445) (end 182.85 119.445) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 183.0434 117.3736) (end 184.4912 117.3736) (width 0.5) (layer B.Cu) (net 34)) + (via (at 146.8836 115.7832) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 146.8836 115.7832) (end 146.8836 114.1664) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 146.8836 117.3876) (end 146.8836 115.7832) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 53.2138) (end 148.5 52.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 153.3262 53.2138) (end 153.625 52.915) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 53.9) (end 148.5 53.2138) (width 0.5) (layer B.Cu) (net 34)) + (via (at 163.5108 112.5814) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 163.481389 112.551989) (end 163.5108 112.5814) (width 0.5) (layer B.Cu) (net 34)) + (via (at 120.909801 123.820001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 105.418 130.194) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 154.7368 93.46499) (end 161.32499 93.46499) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.7 94.84) (end 162.7 96.49) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161.32499 93.46499) (end 162.7 94.84) (width 0.5) (layer F.Cu) (net 34)) + (via (at 148.1328 91.9988) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 149.0472 95.3528) (end 149 95.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 149.07961 93.46499) (end 149.0472 93.4974) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 154.7368 93.46499) (end 149.07961 93.46499) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 149.0472 92.1258) (end 149.0472 93.4974) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 149.0472 93.4974) (end 149.0472 95.3528) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 74.7924) (end 159.9438 73.7362) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 76.815) (end 161 74.7924) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.162004 85.75) (end 200.75 85.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 204.412004 82.5) (end 201.162004 85.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 212.5 81) (end 211 82.5) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 211 82.5) (end 204.8375 82.5) (width 0.5) (layer F.Cu) (net 34)) + (via (at 172.7708 38.9382) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 172.7708 38.9382) (end 169.8244 38.9382) (width 0.5) (layer F.Cu) (net 34)) + (via (at 167.894 37.4396) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 169.8244 38.9382) (end 169.2431 38.3569) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 168.3258 37.4396) (end 167.894 37.4396) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 166.3004 37.4396) (end 165.37 38.37) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 167.894 37.4396) (end 166.3004 37.4396) (width 0.5) (layer B.Cu) (net 34)) + (via (at 211.378787 48.652217) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 218.1 68.75) (end 219.3368 68.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.2 67.8868) (end 220.2 66.65) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 219.3368 68.75) (end 220.2 67.8868) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.684002 68.072) (end 203.454 68.072) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.056001 67.443999) (end 201.684002 68.072) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 203.926 67.6) (end 209.35 67.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 203.454 68.072) (end 203.926 67.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 131.149999 113.052403) (end 131.149999 107.099999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.997596 113.9) (end 131.149999 113.052403) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.7805 118.4907) (end 148.7805 116.974498) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 146.8836 119.1376) (end 148.1336 119.1376) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 148.1336 119.1376) (end 148.7805 118.4907) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 142.1535 117.325) (end 143.383 118.5545) (width 0.5) (layer B.Cu) (net 34)) + (via (at 143.383 118.5545) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 142.4205 118.5545) (end 143.383 118.5545) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 119.075) (end 142.4205 118.5545) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 117.325) (end 142.1535 117.325) (width 0.5) (layer B.Cu) (net 34)) + (via (at 199.099994 48.824994) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 201.75 47.8) (end 201.75 49.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 203.95 51.5) (end 204.5 52.05) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.75 49.3) (end 203.95 51.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 202.025 62.125) (end 202.1205 62.0295) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 202.1205 62.0295) (end 202.1205 60.959998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.535502 60.375) (end 202.1205 60.959998) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.7 62.125) (end 202.025 62.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.7 60.375) (end 201.535502 60.375) (width 0.5) (layer F.Cu) (net 34)) + (via (at 202.1205 60.959998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 161.000002 41.375002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 122.9 62.725) (end 124.4095 62.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 125.250001 61.884499) (end 125.250001 60.399999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.4095 62.725) (end 125.250001 61.884499) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144.999996 98.900004) (end 144.9 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 95.4) (end 144.999996 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 142.6 113.9) (end 141.967 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.967 113.9) (end 131.997596 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.182399 112.252999) (end 163.310801 112.381401) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.310801 112.381401) (end 163.5108 112.5814) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 149.8902 113.9) (end 151.537201 112.252999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 147.15 113.9) (end 149.8902 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 151.537201 112.252999) (end 163.182399 112.252999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 113.9) (end 148.5 112.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 146.8836 113.9744) (end 146.958 113.9) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 146.8836 114.1664) (end 146.8836 113.9744) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 146 113.9) (end 146.958 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 146.958 113.9) (end 148.5 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 83.475) (end 123.1625 83.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 198.6915 49.7205) (end 199.099994 49.312006) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.099994 49.312006) (end 199.099994 48.824994) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 45.450001) (end 187.948034 45.450001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 192.218533 49.7205) (end 198.6915 49.7205) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 187.948034 45.450001) (end 191.549016 49.050984) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 101.946161 133.165961) (end 102.878 134.0978) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 101.915367 133.165961) (end 101.946161 133.165961) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 106.65 125.005) (end 104.681 125.005) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 120 120.2) (end 120 121.1) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 119.478943 121.621057) (end 118.268251 121.621057) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 120 121.1) (end 119.478943 121.621057) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 120.401227 123.311427) (end 120.909801 123.820001) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 118.721184 123.311427) (end 120.401227 123.311427) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 120.909801 123.820001) (end 120.909801 121.109801) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 120.909801 121.109801) (end 119.9 120.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 119.9 120.1) (end 120 120.2) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 161 116.665) (end 161.635 116.665) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 163.5108 112.5814) (end 163.5108 114.7892) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 163.5108 114.7892) (end 162.6 115.7) (width 0.5) (layer F.Cu) (net 34)) + (via (at 162.6 115.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 161.635 116.665) (end 162.6 115.7) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.115 114.915) (end 162.6 115.4) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 114.915) (end 162.115 114.915) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 162.6 115.4) (end 162.6 115.7) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 79.225) (end 141.9 77.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.82499 77.42499) (end 141.82499 77.12499) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 77.5) (end 141.82499 77.42499) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.82499 77.12499) (end 140.8 76.1) (width 0.5) (layer B.Cu) (net 34)) + (via (at 127.800001 76.100001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 127.800002 76.1) (end 127.800001 76.100001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 140.8 76.1) (end 139.4 76.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 127.800001 64.164999) (end 127.800001 76.100001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 127.800001 76.100001) (end 127.800001 77.748007) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 181.200002 118.299998) (end 181.200002 117.425) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 180 119.175) (end 180.325 119.175) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 180.325 119.175) (end 181.200002 118.299998) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 141.9 116.2) (end 142.5 115.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 117.325) (end 141.9 116.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 142.5 114) (end 142.6 113.9) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 142.5 115.6) (end 142.5 114) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 208.6 50) (end 209.947783 48.652217) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.947783 48.652217) (end 211.378787 48.652217) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 207.2 50) (end 208.6 50) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 204.5 52.05) (end 205.15 52.05) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 205.15 52.05) (end 207.2 50) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 169.2431 38.3569) (end 168.3258 37.4396) (width 0.5) (layer F.Cu) (net 34) (tstamp 5F808024)) + (segment (start 139.4 76.1) (end 127.800002 76.1) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F808028)) + (via (at 139.4 76.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 101.7) (end 148.5 95.4) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F80802A)) + (via (at 148.5 101.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 112.3) (end 148.5 101.7) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F80802C)) + (via (at 148.5 112.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 151.899698 40.525011) (end 153.814687 42.44) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 160.401831 42.44) (end 161.000002 41.841829) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 151.749698 40.525011) (end 151.899698 40.525011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 149.362989 40.137011) (end 151.361698 40.137011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 151.361698 40.137011) (end 151.749698 40.525011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161.000002 41.841829) (end 161.000002 41.375002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 153.814687 42.44) (end 160.401831 42.44) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 41) (end 149.362989 40.137011) (width 0.5) (layer B.Cu) (net 34)) + (via (at 156.8069 132.2705) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 206.629 96.1009) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 99.9998 104.4956) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 204.8375 82.5) (end 204.412004 82.5) (width 0.5) (layer F.Cu) (net 34) (tstamp 5F885627)) + (via (at 204.8375 82.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 102 87.325) (end 102 86) (width 0.5) (layer F.Cu) (net 34)) + (via (at 102 86) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 103.55 87.375) (end 102.05 87.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 102.05 87.375) (end 102 87.325) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.175 86) (end 103.55 85.625) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 102 86) (end 103.175 86) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.638 76) (end 105.4 77.238) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.4 87.025) (end 105.4 84) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.4 77.238) (end 105.4 84) (width 0.5) (layer B.Cu) (net 34)) + (via (at 105.4 84) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 103.55 87.375) (end 105.05 87.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.05 87.375) (end 105.4 87.025) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 107.9 76) (end 106.638 76) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 211.378787 48.652217) (end 211.378787 49.178787) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 211.378787 49.178787) (end 212 49.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.2 49.143876) (end 218.2 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 217.543876 49.8) (end 218.2 49.143876) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 212 49.8) (end 217.543876 49.8) (width 0.5) (layer F.Cu) (net 34)) + (via (at 220.4 47.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 218.2 47.775) (end 220.375 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.375 47.775) (end 220.4 47.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.4 47.8) (end 220.4 46.4) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.4 46.4) (end 220 46) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.975 46.025) (end 218.2 46.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220 46) (end 219.975 46.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.15 101.35) (end 218.15 103.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218 101.2) (end 218.15 101.35) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 217.8 101.2) (end 217.7 101.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.262002 101.2) (end 217.8 101.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.175021 104.874979) (end 220.175021 102.113019) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 217.7 101.1) (end 215.8 101.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.175021 102.113019) (end 219.262002 101.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 172.909 38.8) (end 172.7708 38.9382) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.945 38.8) (end 172.909 38.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.05 43.2) (end 184.05 39.905) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.05 39.905) (end 182.945 38.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 212.906 101.1) (end 215.8 101.1) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 202.55 103.2) (end 206.064998 103.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.5 104.25) (end 202.55 103.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 206.064998 103.2) (end 207.364999 104.500001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 207.364999 104.500001) (end 209.505999 104.500001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.505999 104.500001) (end 212.906 101.1) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.418 132.182) (end 105.418 130.194) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.418 132.182) (end 105.418 132.768814) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.418 132.768814) (end 104.236815 133.949999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 104.236815 133.949999) (end 104.236815 133.963185) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 104.236815 133.963185) (end 103.8 134.4) (width 0.5) (layer B.Cu) (net 34)) + (via (at 103.8 134.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 103.149406 134.4) (end 101.915367 133.165961) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.8 134.4) (end 103.149406 134.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.8 132.660049) (end 103.430912 132.290961) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 103.8 134.4) (end 103.8 132.660049) (width 0.5) (layer B.Cu) (net 34)) + (via (at 140.8 132.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 170.4 132.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 217 81) (end 216.85 81) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0731)) + (via (at 217 81) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 191.549016 49.050984) (end 192.218533 49.7205) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0733)) + (via (at 191.549016 49.050984) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 64.7) (end 148.5 61.5) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0735)) + (segment (start 148.5 61.5) (end 148.5 60.15) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0737)) + (via (at 133 78) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 46.1) (end 148.5 40.9) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0739)) + (segment (start 165.37 38.37) (end 163.85 39.89) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC073B)) + (via (at 165.37 38.37) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 125.67499 125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 125.67499 118.990008) (end 125.67499 125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.935798 117.7292) (end 125.67499 118.990008) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 125.07499 125.6) (end 125.67499 125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 130.3638 117.7292) (end 126.935798 117.7292) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.75 116.343) (end 130.3638 117.7292) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.75 114) (end 131.75 116.343) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.6898 125.6) (end 125.07499 125.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 120.909801 123.820001) (end 122.6898 125.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.65 123.255) (end 108.15 123.255) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 109.884988 120.401826) (end 111.411803 118.875011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 111.411803 118.875011) (end 118.675011 118.875011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 109.884988 121.520012) (end 109.884988 120.401826) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 108.15 123.255) (end 109.884988 121.520012) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 118.675011 118.875011) (end 119.9 120.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 104.6 124.055) (end 104.6 125.086) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.4 123.255) (end 104.6 124.055) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.65 123.255) (end 105.4 123.255) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.418 127.018) (end 105.418 130.194) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.6 125.2) (end 104.6 126.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.6 126.2) (end 105.418 127.018) (width 0.5) (layer F.Cu) (net 34)) + (via (at 169.7228 56.1848) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 167.0304 56.1848) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 169.7228 56.1848) (end 167.0304 56.1848) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 165.137002 58.365) (end 162.95 58.365) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 167.0304 56.471602) (end 165.137002 58.365) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 167.0304 56.1848) (end 167.0304 56.471602) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 169.7076 56.2) (end 169.7228 56.1848) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 177.544076 56.2) (end 169.7076 56.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 58.655924) (end 177.544076 56.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 60.125) (end 180 58.655924) (width 0.5) (layer B.Cu) (net 34)) + (via (at 209.45 64.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 209.45 64.25) (end 209.45 59.7) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 206.6756 53.5756) (end 205.15 52.05) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 206.6756 56.9256) (end 206.6756 53.5756) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.45 59.7) (end 206.6756 56.9256) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 186.5 85.662) (end 185.187 84.349) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 91.574999) (end 186.5 91.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 105.574999) (end 186.924999 102.152401) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 91.15) (end 186.5 85.662) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 185.187 79.65) (end 182 79.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 185.187 84.349) (end 185.187 79.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 79.65) (end 185.187 79.65) (width 0.5) (layer B.Cu) (net 34)) + (via (at 189.992 80.4418) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 172.7708 76.3778) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.924999 102.152401) (end 186.924999 91.574999) (width 0.5) (layer B.Cu) (net 34) (tstamp 61CC37ED)) + (via (at 186.924999 102.152401) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 168.021 95.7834) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 171.4246 100.3046) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 173.8376 102.4636) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 173.6344 115.7224) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 168.4274 110.0836) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 185.5978 85.5472) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 185.0644 77.4446) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 167.8686 121.158) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 131.9784 118.3894) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 111.4806 114.6556) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 128.6764 92.6592) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 114.0714 102.3874) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 113.792 63.1444) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 113.1062 69.0118) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 117.3198 85.55) (end 123.95 85.55) (width 0.5) (layer F.Cu) (net 34) (tstamp 61CC3F51)) + (via (at 117.3198 85.55) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 136.3218 96.0628) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.3446 63.246) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.37 60.1472) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.7256 50.165) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.243 45.339) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 185.5978 123.6472) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 149.0218 127.2032) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 96.7232 125.5522) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 150.0632 36.8808) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 174.371 36.8808) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 133.8072 101.8794) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 130.3782 110.1344) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 131.8768 122.7074) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 152.6032 98.8822) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 117.729 104.5718) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 122.5804 97.282) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 135.1026 115.9256) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.7805 116.974498) (end 147.589202 115.7832) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 147.589202 115.7832) (end 146.8836 115.7832) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 152.196 53.2138) (end 148.5 53.2138) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 153.3262 53.2138) (end 152.196 53.2138) (width 0.5) (layer B.Cu) (net 34)) + (via (at 146.939 46.2788) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 220.5 59.75) (end 220.5 58.42) (width 0.25) (layer F.Cu) (net 35) (tstamp 5F754BC2)) + (segment (start 220.5 58.42) (end 221.4 57.52) (width 0.25) (layer F.Cu) (net 35) (tstamp 5F754BC3)) + (via (at 220.5 59.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35) (tstamp 5F754BC8)) + (segment (start 106.17 57.67) (end 107.47 56.37) (width 0.25) (layer F.Cu) (net 35) (tstamp 5AB4FE5D) (status 20)) + (segment (start 106.165745 57.665745) (end 106.17 57.67) (width 0.25) (layer F.Cu) (net 35)) + (via (at 102.675 57.665745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 102.675 57.665745) (end 93.478815 57.665745) (width 0.25) (layer F.Cu) (net 35) (status 20)) + (segment (start 106.165745 57.665745) (end 102.675 57.665745) (width 0.25) (layer F.Cu) (net 35)) + (via (at 220.75 97.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 210 95.62) (end 212.13 97.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 212.13 97.75) (end 220.75 97.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 220.75 97.75) (end 220.75 96.27) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 61.305001) (end 220.5 59.75) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.4 72.567002) (end 222.055001 71.912001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 71.912001) (end 222.055001 61.305001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.4 76.42) (end 221.4 72.567002) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 81.305001) (end 222.055001 81.055001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 210.05 76.62) (end 211.979989 78.549989) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 222.055001 79.979991) (end 220.55 78.47499) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.55 77.52) (end 220.55 78.47499) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.475001 78.549989) (end 220.55 78.47499) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 221.45 76.62) (end 220.55 77.52) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 211.979989 78.549989) (end 220.475001 78.549989) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 222.055001 81.055001) (end 222.055001 79.979991) (width 0.25) (layer F.Cu) (net 35)) + (via (at 220.55 78.47499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 222.055001 87.805001) (end 222.055001 81.055001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.4 95.62) (end 222.055001 94.964999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 94.964999) (end 222.055001 87.805001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.75 96.27) (end 221.4 95.62) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 114.62) (end 220.75 113.92) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 210.05 114.62) (end 210.05 116.47499) (width 0.25) (layer B.Cu) (net 35)) + (via (at 210 116.49999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 210.05 114.62) (end 210.05 116.44999) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 210.05 116.44999) (end 210 116.49999) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 210.025 116.47499) (end 210 116.49999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 114.62) (end 221.45 116.132842) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.107852 116.47499) (end 210.025 116.47499) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 116.132842) (end 221.107852 116.47499) (width 0.25) (layer F.Cu) (net 35)) + (via (at 177.303 130.988) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 171.9 128.92) (end 173.968 130.988) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 173.968 130.988) (end 177.303 130.988) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 181.232 130.988) (end 183.3 128.92) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 177.303 130.988) (end 181.232 130.988) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.75 100.71359) (end 220.75 96.27) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.275009 101.238599) (end 220.75 100.71359) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.85 113.37) (end 222.85 107.35) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.6 114.62) (end 222.85 113.37) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 114.62) (end 221.6 114.62) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.85 107.35) (end 221.275009 105.775009) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.275009 105.775009) (end 221.275009 101.238599) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 202.929 118) (end 204.42901 116.49999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 204.42901 116.49999) (end 210 116.49999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 194.3565 118) (end 202.929 118) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 183.3 128.92) (end 183.4365 128.92) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 183.4365 128.92) (end 194.3565 118) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 188.825423 38.2) (end 188.854605 38.204605) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 169.90858 36.38078) (end 171.7278 38.2) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 153 37.75) (end 154.36922 36.38078) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 171.7278 38.2) (end 188.825423 38.2) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 102.675 41.054355) (end 105.964678 37.764678) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 188.854605 38.204605) (end 189.05 38.4) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 154.36922 36.38078) (end 169.90858 36.38078) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 152.214678 37.764678) (end 152.229356 37.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 102.675 57.665745) (end 102.675 41.054355) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 105.964678 37.764678) (end 152.214678 37.764678) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 152.229356 37.75) (end 153 37.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 194.2364 43.5864) (end 189.054628 38.404628) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 208.0006 43.5864) (end 194.2364 43.5864) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 212.2462 59.7662) (end 209.25 56.77) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 209.25 44.8358) (end 208.0006 43.5864) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 209.25 56.77) (end 209.25 44.8358) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 220.5162 59.7662) (end 212.2462 59.7662) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 220.5 59.75) (end 220.5162 59.7662) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 201.3 58.52) (end 202.2 57.62) (width 0.25) (layer F.Cu) (net 36) (tstamp 5F754BC3)) + (segment (start 190.8 57.62) (end 190.82 57.62) (width 0.25) (layer B.Cu) (net 36) (tstamp 5F754BC4)) + (segment (start 201.5 78.65) (end 201.5 77.32) (width 0.25) (layer F.Cu) (net 36) (tstamp 5F754BC2)) + (segment (start 201.5 77.32) (end 202.4 76.42) (width 0.25) (layer F.Cu) (net 36) (tstamp 5F754BC3)) + (segment (start 191 76.42) (end 191.02 76.42) (width 0.25) (layer B.Cu) (net 36) (tstamp 5F754BC4)) + (via (at 201.5 78.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36) (tstamp 5F754BC8)) + (segment (start 106.224255 60.205745) (end 107.42 59.01) (width 0.25) (layer F.Cu) (net 36) (status 20)) + (via (at 103.175 60.205745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 103.175 60.205745) (end 106.224255 60.205745) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 93.478815 60.205745) (end 103.175 60.205745) (width 0.25) (layer F.Cu) (net 36) (status 10)) + (via (at 189.275 57.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 190.73 57.25) (end 191 57.52) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.275 57.25) (end 190.73 57.25) (width 0.25) (layer B.Cu) (net 36)) + (via (at 188 46.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 189.275 57.25) (end 189.275 47.775) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.275 47.775) (end 188 46.5) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 188 46.5) (end 181.5 40) (width 0.25) (layer F.Cu) (net 36)) + (via (at 181.5 39.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (via (at 190.85 77.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 201.5 78.65) (end 191.6 78.65) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 191.6 78.65) (end 190.85 77.9) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 190.85 76.57) (end 191 76.42) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.85 77.9) (end 190.85 76.57) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.275 58.312502) (end 189.275 57.25) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 190.199998 59.2375) (end 189.275 58.312502) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 190.05 64.4) (end 190.15 64.3) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.199998 64.250002) (end 190.15 64.3) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 191 76.42) (end 191 75.17) (width 0.25) (layer B.Cu) (net 36)) + (via (at 190.15 64.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 191 75.17) (end 190.05 74.22) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.05 74.22) (end 190.05 64.4) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.199998 59.2375) (end 190.199998 64.250002) (width 0.25) (layer F.Cu) (net 36)) + (via (at 191.2984 119.9136) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 172.67459 120.93521) (end 179.514489 120.93521) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.191999 122.020001) (end 191.2984 119.9136) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 179.514489 120.93521) (end 180.59928 122.020001) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 180.59928 122.020001) (end 189.191999 122.020001) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 191 114.62) (end 193.276189 116.896189) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 193.276189 116.896189) (end 201.008609 116.896189) (width 0.25) (layer B.Cu) (net 36)) + (via (at 193.276189 116.9842) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 191.2984 119.9136) (end 191.2984 118.961989) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 191.2984 118.961989) (end 193.276189 116.9842) (width 0.25) (layer F.Cu) (net 36)) + (via (at 202.005399 115.899399) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 201.008609 116.896189) (end 202.005399 115.899399) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.267499 59.305001) (end 190.199998 59.2375) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 202.4 57.52) (end 200.614999 59.305001) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 200.614999 59.305001) (end 190.267499 59.305001) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 203.2 93.57) (end 203.2 87.1855) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 202.4 94.37) (end 203.2 93.57) (width 0.25) (layer F.Cu) (net 36)) + (via (at 203.2 87.1855) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 201.5 78.65) (end 203.2 80.35) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 203.2 80.35) (end 203.2 87.1855) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.4 95.62) (end 202.4 94.37) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 167.177 126.41) (end 167.1884 126.4214) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 164.3 126.41) (end 167.177 126.41) (width 0.25) (layer F.Cu) (net 36)) + (via (at 167.1884 126.4214) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 167.1884 126.4214) (end 172.67459 120.93521) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 164.3 126.41) (end 164.3 127.66) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 163.6265 128.3335) (end 158.6865 128.3335) (width 0.25) (layer F.Cu) (net 36)) + (via (at 158.6865 128.3335) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 164.3 127.66) (end 163.6265 128.3335) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 152.9 126.41) (end 154.793988 128.303988) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 158.656988 128.303988) (end 158.6865 128.3335) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 154.793988 128.303988) (end 158.656988 128.303988) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 191.05 95.62) (end 192.89285 97.46285) (width 0.25) (layer B.Cu) (net 36)) + (via (at 201.272457 97.46285) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 192.89285 97.46285) (end 201.272457 97.46285) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.45 95.62) (end 201.272457 96.797543) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 201.272457 96.797543) (end 201.272457 97.46285) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 201.272457 101.972457) (end 201.272457 97.46285) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.005399 115.014601) (end 202.005399 115.899399) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 202.4 114.62) (end 202.005399 115.014601) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 175 39.6) (end 175.15001 39.44999) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 172.4742 39.6) (end 175 39.6) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 169.70499 36.83079) (end 172.4742 39.6) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 155.01921 36.83079) (end 169.70499 36.83079) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 181.04999 39.44999) (end 181.5 39.9) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 153.55 38.3) (end 155.01921 36.83079) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 103.2 60.180745) (end 103.2 41.165767) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 103.175 60.205745) (end 103.2 60.180745) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 103.2 41.165767) (end 106.065768 38.3) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 175.15001 39.44999) (end 181.04999 39.44999) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 106.065768 38.3) (end 153.55 38.3) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 201.272457 101.972457) (end 201.272457 102.272457) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 201.272457 102.272457) (end 202.8 103.8) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.8 103.8) (end 203.6 104.6) (width 0.25) (layer B.Cu) (net 36)) + (via (at 203.6 110) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 203.6 104.6) (end 203.6 110) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 203.6 113.42) (end 202.4 114.62) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 203.6 110) (end 203.6 113.42) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 182.4 92.95) (end 182.4 91.62) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC2)) + (segment (start 182.4 91.62) (end 183.3 90.72) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC3)) + (segment (start 171.9 90.72) (end 171.92 90.72) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC4)) + (segment (start 171.92 90.72) (end 174.15 92.95) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC5)) + (segment (start 174.15 92.95) (end 182.4 92.95) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC6)) + (via (at 182.4 92.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37) (tstamp 5F754BC8)) + (segment (start 182.4 54.85) (end 182.4 53.52) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC2)) + (segment (start 182.4 53.52) (end 183.3 52.62) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC3)) + (segment (start 171.9 52.62) (end 171.92 52.62) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC4)) + (segment (start 171.92 52.62) (end 174.15 54.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC5)) + (segment (start 174.15 54.85) (end 182.4 54.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC6)) + (via (at 182.4 54.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37) (tstamp 5F754BC8)) + (segment (start 182.4 73.85) (end 182.4 72.52) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC2)) + (segment (start 182.4 72.52) (end 183.3 71.62) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC3)) + (segment (start 171.9 71.62) (end 171.92 71.62) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC4)) + (segment (start 171.92 71.62) (end 174.15 73.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC5)) + (segment (start 174.15 73.85) (end 182.4 73.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC6)) + (via (at 182.4 73.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37) (tstamp 5F754BC8)) + (segment (start 107.42 61.55) (end 106.224255 62.745745) (width 0.25) (layer F.Cu) (net 37) (status 10)) + (segment (start 103.7 62.745745) (end 93.478815 62.745745) (width 0.25) (layer F.Cu) (net 37) (status 20)) + (via (at 103.7 62.745745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 106.224255 62.745745) (end 103.7 62.745745) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 86.212001) (end 183.955001 84.105001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 90.72) (end 183.3 86.867002) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 86.867002) (end 183.955001 86.212001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 74.7) (end 182.4 73.85) (width 0.25) (layer F.Cu) (net 37)) + (via (at 183.25 64.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 183.955001 65.605001) (end 183.25 64.9) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 71.62) (end 183.955001 70.964999) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 70.964999) (end 183.955001 65.605001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 105.312001) (end 183.955001 94.505001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 105.967002) (end 183.955001 105.312001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 94.505001) (end 182.4 92.95) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 109.82) (end 183.3 105.967002) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 173.779989 111.699989) (end 181.207533 111.699989) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 182.091239 111.028761) (end 181.878761 111.028761) (width 0.25) (layer F.Cu) (net 37)) + (via (at 181.878761 111.028761) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 171.9 109.82) (end 173.779989 111.699989) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 183.3 109.82) (end 182.091239 111.028761) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 181.207533 111.699989) (end 181.878761 111.028761) (width 0.25) (layer B.Cu) (net 37)) + (via (at 173.779989 111.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 182.4 54.85) (end 182.950011 55.400011) (width 0.25) (layer F.Cu) (net 37)) + (via (at 182.950011 61.131673) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 182.950011 55.400011) (end 182.950011 61.131673) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 182.950011 64.600011) (end 182.950011 61.131673) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 183.25 64.9) (end 182.950011 64.600011) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 173.779989 111.625) (end 173.779989 113.454411) (width 0.25) (layer F.Cu) (net 37)) + (via (at 171.969 115.2654) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 173.779989 113.454411) (end 171.969 115.2654) (width 0.25) (layer F.Cu) (net 37)) + (via (at 147.7882 129.354) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 145.734 129.354) (end 145.2 128.82) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 147.7882 129.354) (end 145.734 129.354) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 138.565323 130.933999) (end 138.831761 130.667561) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 133.8 130.07) (end 134.663999 130.933999) (width 0.25) (layer B.Cu) (net 37)) + (via (at 138.831761 130.667561) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 138.8728 130.7086) (end 138.831761 130.667561) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 144.5614 130.7086) (end 138.8728 130.7086) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 145.2 130.07) (end 144.5614 130.7086) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 145.2 128.82) (end 145.2 130.07) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 134.663999 130.933999) (end 138.565323 130.933999) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 133.8 128.82) (end 133.8 130.07) (width 0.25) (layer B.Cu) (net 37)) + (via (at 162.6362 42.5958) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 162.6362 42.5958) (end 166.9034 42.5958) (width 0.25) (layer B.Cu) (net 37)) + (via (at 166.9288 42.5704) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 166.9034 42.5958) (end 166.9288 42.5704) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 168.9354 42.5704) (end 169.0116 42.4942) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 171.9 52.62) (end 170.694399 51.414399) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 166.9288 42.5704) (end 168.9354 42.5704) (width 0.25) (layer F.Cu) (net 37)) + (via (at 169.0116 42.4942) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 170.694399 43.436957) (end 169.751642 42.4942) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 170.694399 51.414399) (end 170.694399 43.436957) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 169.751642 42.4942) (end 169.0116 42.4942) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 155.544253 42.624999) (end 152.723174 39.80392) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 162.6362 42.5958) (end 162.665001 42.624601) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 162.665001 42.624999) (end 155.544253 42.624999) (width 0.25) (layer F.Cu) (net 37)) + (via (at 152.723174 39.80392) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 162.665001 42.624601) (end 162.665001 42.624999) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 157.833011 129.354) (end 147.7882 129.354) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 171.969 115.2654) (end 171.969 120.236002) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 171.969 120.236002) (end 162.851002 129.354) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 162.851002 129.354) (end 157.833011 129.354) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 152.723174 39.315661) (end 152.723174 39.80392) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 152.607513 39.2) (end 152.723174 39.315661) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 141.90371 39.2) (end 148.850403 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 137.09629 39.2) (end 137.397911 38.898379) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 105.802177 39.2) (end 137.09629 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 137.397911 38.898379) (end 141.602089 38.898379) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 103.7 41.302177) (end 105.802177 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 151.786274 39.11199) (end 151.874284 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 148.938413 39.11199) (end 151.786274 39.11199) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 148.850403 39.2) (end 148.938413 39.11199) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 151.874284 39.2) (end 152.607513 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 141.602089 38.898379) (end 141.90371 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 103.7 62.745745) (end 103.7 41.302177) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 183.25 83.4) (end 183.6814 83.8314) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.6814 83.8314) (end 183.5 83.65) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 81.4942) (end 183.25 83.4) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 81.4942) (end 183.25 74.7) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 81.65) (end 183.25 81.4942) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 84.105001) (end 183.6814 83.8314) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 152.55 50.41) (end 152.57 50.41) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 163.3 90.64) (end 163.3 89.31) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC2)) + (segment (start 163.3 89.31) (end 164.2 88.41) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC3)) + (segment (start 152.8 88.41) (end 152.82 88.41) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 152.82 88.41) (end 155.05 90.64) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC5)) + (segment (start 155.05 90.64) (end 163.3 90.64) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC6)) + (via (at 163.3 90.64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38) (tstamp 5F754BC8)) + (segment (start 163.4 71.44) (end 163.4 70.11) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC2)) + (segment (start 163.4 70.11) (end 164.3 69.21) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC3)) + (segment (start 152.9 69.21) (end 152.92 69.21) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 152.92 69.21) (end 155.15 71.44) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC5)) + (segment (start 155.15 71.44) (end 163.4 71.44) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC6)) + (via (at 163.4 71.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38) (tstamp 5F754BC8)) + (segment (start 163.4 109.54) (end 163.4 108.21) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC2)) + (segment (start 163.4 108.21) (end 164.3 107.31) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC3)) + (segment (start 152.9 107.31) (end 152.92 107.31) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 155.15 109.54) (end 163.4 109.54) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC6)) + (via (at 163.4 109.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38) (tstamp 5F754BC8)) + (via (at 104.3 64.575) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 106.935 64.575) (end 107.42 64.09) (width 0.25) (layer F.Cu) (net 38) (status 30)) + (segment (start 104.3 64.575) (end 106.935 64.575) (width 0.25) (layer F.Cu) (net 38) (status 20)) + (segment (start 94.18956 64.575) (end 93.478815 65.285745) (width 0.25) (layer F.Cu) (net 38) (status 20)) + (segment (start 104.3 64.575) (end 94.18956 64.575) (width 0.25) (layer F.Cu) (net 38)) + (via (at 150.25 52.265) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 152.395 50.12) (end 152.9 50.12) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 150.25 52.265) (end 152.395 50.12) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 164.955001 106.654999) (end 164.3 107.31) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.955001 92.295001) (end 164.955001 106.654999) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 163.3 90.64) (end 164.955001 92.295001) (width 0.25) (layer F.Cu) (net 38)) + (via (at 165 78.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 165 73.04) (end 163.4 71.44) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165 78.54) (end 165 73.04) (width 0.25) (layer F.Cu) (net 38)) + (via (at 151.75 63.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 152.9 69.21) (end 151.75 68.06) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 151.75 68.06) (end 151.75 63.54) (width 0.25) (layer B.Cu) (net 38)) + (via (at 153 109.04) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 153 107.41) (end 152.9 107.31) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 153 109.04) (end 153 107.41) (width 0.25) (layer B.Cu) (net 38)) + (via (at 165 81.540021) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 165 87.61) (end 165 81.540021) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.3 88.31) (end 165 87.61) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165 78.54) (end 165 81.540021) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.25 63.04) (end 151.75 63.54) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.25 56.64) (end 152.25 63.04) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.64999 56.24001) (end 152.25 56.64) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.9 55.99) (end 152.64999 56.24001) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.55 55.99) (end 152.9 55.99) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165.775001 54.764999) (end 164.55 55.99) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.3 50.12) (end 165.775001 51.595001) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165.775001 51.595001) (end 165.775001 54.764999) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.9 54.915) (end 150.25 52.265) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.9 55.99) (end 152.9 54.915) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 151.99998 41.690505) (end 152.070275 41.62021) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 151.99998 47.96998) (end 151.99998 41.690505) (width 0.25) (layer B.Cu) (net 38)) + (via (at 152.070275 41.62021) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 152.9 50.12) (end 152.9 48.87) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.9 48.87) (end 151.99998 47.96998) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 153 109.04) (end 153.4975 109.5375) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 155.1475 109.5375) (end 155.15 109.54) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 153.4975 109.5375) (end 155.1475 109.5375) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 114.387872 135.789305) (end 119.960695 135.789305) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 113.419376 134.820809) (end 114.387872 135.789305) (width 0.25) (layer B.Cu) (net 38)) + (via (at 123.5 133.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 119.960695 135.789305) (end 121.210695 135.789305) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 121.210695 135.789305) (end 123.5 133.5) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 123.5 132.801203) (end 124.430931 131.870272) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 123.5 133.5) (end 123.5 132.801203) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 141.71731 39.650011) (end 149.036803 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 137.28269 39.650011) (end 137.584311 39.34839) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 151.912883 39.87501) (end 152.061699 39.87501) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.070275 41.62021) (end 152.070275 39.883586) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 104.3 64.575) (end 104.3 41.388592) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 149.124813 39.562001) (end 151.599874 39.562001) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 104.3 41.388592) (end 106.038581 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 149.036803 39.650011) (end 149.124813 39.562001) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 137.584311 39.34839) (end 141.415689 39.34839) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 141.415689 39.34839) (end 141.71731 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 106.038581 39.650011) (end 137.28269 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (via (at 152.061699 39.87501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 151.599874 39.562001) (end 151.912883 39.87501) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.070275 39.883586) (end 152.061699 39.87501) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 126.2 130.101203) (end 124.430931 131.870272) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 129.635595 114.892799) (end 126.2 118.328394) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 135.537001 114.892799) (end 129.635595 114.892799) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 135.9772 114.4526) (end 135.537001 114.892799) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 150.1519 114.4526) (end 135.9772 114.4526) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 153 111.6045) (end 150.1519 114.4526) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 126.2 118.328394) (end 126.2 130.101203) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 153 109.04) (end 153 111.6045) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 144.3 54.9) (end 144.3 53.57) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC2)) + (segment (start 144.3 53.57) (end 145.2 52.67) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC3)) + (via (at 144.3 54.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39) (tstamp 5F754BC8)) + (segment (start 144.3 73.9) (end 144.3 72.57) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC2)) + (segment (start 144.3 72.57) (end 145.2 71.67) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC3)) + (segment (start 133.8 71.67) (end 133.82 71.67) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC4)) + (segment (start 133.82 71.67) (end 136.05 73.9) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC5)) + (segment (start 136.05 73.9) (end 144.3 73.9) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC6)) + (via (at 144.3 73.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39) (tstamp 5F754BC8)) + (segment (start 144.3 111.95) (end 144.3 110.62) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC2)) + (segment (start 144.3 110.62) (end 145.2 109.72) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC3)) + (segment (start 133.8 109.72) (end 133.82 109.72) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC4)) + (segment (start 133.82 109.72) (end 136.05 111.95) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC5)) + (segment (start 136.05 111.95) (end 144.3 111.95) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC6)) + (via (at 144.3 111.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39) (tstamp 5F754BC8)) + (segment (start 105.199999 66.199999) (end 105 66) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 107.42 66.63) (end 105.63 66.63) (width 0.25) (layer F.Cu) (net 39) (status 10)) + (segment (start 105.63 66.63) (end 105.199999 66.199999) (width 0.25) (layer F.Cu) (net 39)) + (via (at 105 66) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 95.754549 65.550011) (end 104.550011 65.550011) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 93.478815 67.825745) (end 95.754549 65.550011) (width 0.25) (layer F.Cu) (net 39) (status 10)) + (segment (start 104.800001 65.800001) (end 105 66) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 104.550011 65.550011) (end 104.800001 65.800001) (width 0.25) (layer F.Cu) (net 39)) + (via (at 133.25 111.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 133.25 110.27) (end 133.8 109.72) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.25 111.3) (end 133.25 110.27) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 145.855001 89.964999) (end 145.2 90.62) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 75.455001) (end 145.855001 89.964999) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 144.3 73.9) (end 145.855001 75.455001) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 70.964999) (end 145.2 71.62) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 56.455001) (end 145.855001 70.964999) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 144.3 54.9) (end 145.855001 56.455001) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 143.767158 92.52499) (end 144.05 92.52499) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 135.40499 92.52499) (end 143.767158 92.52499) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.55 90.67) (end 135.40499 92.52499) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 144.95 90.67) (end 144.05 91.57) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 109.064999) (end 145.855001 94.329991) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 144.05 91.57) (end 144.05 92.52499) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.2 109.72) (end 145.855001 109.064999) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 94.329991) (end 144.05 92.52499) (width 0.25) (layer F.Cu) (net 39)) + (via (at 144.05 92.52499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 132.775355 50.245355) (end 132.775355 45.504242) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 132.775355 45.504242) (end 132.975354 45.304243) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.8 51.27) (end 132.775355 50.245355) (width 0.25) (layer B.Cu) (net 39)) + (via (at 132.975354 45.304243) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 133.8 52.52) (end 133.8 51.27) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133 45.279597) (end 132.975354 45.304243) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 132.975354 42.874646) (end 133.154739 42.695261) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 132.975354 45.304243) (end 132.975354 42.874646) (width 0.25) (layer F.Cu) (net 39)) + (via (at 133.154739 42.695261) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (via (at 88.273 133.285) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 132.75 111.4) (end 130.773547 113.376453) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 130.773547 113.376453) (end 130.773547 113.628547) (width 0.25) (layer F.Cu) (net 39)) + (via (at 130.773547 113.628547) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 144.2725 54.9275) (end 144.3 54.9) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 136.0575 54.9275) (end 144.2725 54.9275) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.8 52.67) (end 136.0575 54.9275) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 93.636229 140.896345) (end 91 138.260116) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 95.12595 140.896345) (end 93.636229 140.896345) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 91 138.260116) (end 91 137) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 88.273 134.273) (end 88.273 133.285) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 91 137) (end 88.273 134.273) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 88.273 132.176605) (end 89.42595 131.023655) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 88.273 133.285) (end 88.273 132.176605) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 132.85 111.3) (end 133.25 111.3) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 132.75 111.4) (end 132.85 111.3) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 105 41.325002) (end 106.174991 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 107.948773 40.150011) (end 130.609489 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.609489 40.150011) (end 133.154739 42.695261) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 106.898239 40.142999) (end 107.941761 40.142999) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 107.941761 40.142999) (end 107.948773 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 106.891227 40.150011) (end 106.898239 40.142999) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 105 66) (end 105 41.325002) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 106.174991 40.150011) (end 106.891227 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 97.918502 122.531102) (end 89.42595 131.023655) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 98.624805 121.824799) (end 97.918502 122.531102) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 105.175201 121.824799) (end 98.624805 121.824799) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 111.901602 116.501602) (end 109.403204 119) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 109.403204 119) (end 108 119) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.031602 116.501602) (end 111.901602 116.501602) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.773547 115.759657) (end 130.031602 116.501602) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 108 119) (end 105.175201 121.824799) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.773547 113.628547) (end 130.773547 115.759657) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 91.877307 51.39) (end 92.18 51.39) (width 0.25) (layer F.Cu) (net 40) (status 30)) + (via (at 105.6 51.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 98.153565 67.600055) (end 102.800055 67.600055) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.7 68.79962) (end 96.954 68.79962) (width 0.25) (layer F.Cu) (net 40) (status 30)) + (segment (start 96.954 68.79962) (end 98.153565 67.600055) (width 0.25) (layer F.Cu) (net 40) (status 10)) + (segment (start 102.800055 67.600055) (end 102.900001 67.700001) (width 0.25) (layer F.Cu) (net 40)) + (via (at 96.1 51.39) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 92.18 51.39) (end 96.1 51.39) (width 0.25) (layer F.Cu) (net 40) (status 10)) + (segment (start 105.59 51.39) (end 105.6 51.4) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.1 51.39) (end 105.59 51.39) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.05 51.44) (end 96.1 51.39) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 102.900001 67.700001) (end 103.1 67.9) (width 0.25) (layer F.Cu) (net 40)) + (via (at 96.05 67.805847) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 96.05 67.805847) (end 96.05 51.44) (width 0.25) (layer B.Cu) (net 40)) + (via (at 103.1 67.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 105.6 51.4) (end 106.785745 52.585745) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 106.785745 52.585745) (end 108.718815 52.585745) (width 0.25) (layer B.Cu) (net 40) (status 20)) + (segment (start 96.05 68.364) (end 96.05 67.805847) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.7 68.79962) (end 96.48562 68.79962) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.48562 68.79962) (end 96.05 68.364) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 101.277771 79.613466) (end 100.579272 80.311965) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 101.602773 77.682445) (end 101.602773 79.288464) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 102.803501 69.535499) (end 102.803501 76.481717) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 103.53938 68.79962) (end 102.803501 69.535499) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 102.803501 76.481717) (end 101.602773 77.682445) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 104.3 68.79962) (end 103.53938 68.79962) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 101.602773 79.288464) (end 101.277771 79.613466) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 103.1 68.302) (end 103.1 67.9) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 103.59762 68.79962) (end 103.1 68.302) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 104.3 68.79962) (end 103.59762 68.79962) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 92.18 41.23) (end 105.330006 41.23) (width 0.25) (layer F.Cu) (net 41) (status 10)) + (segment (start 105.330006 41.23) (end 105.500007 41.400001) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 105.500007 41.400001) (end 105.700006 41.6) (width 0.25) (layer F.Cu) (net 41)) + (via (at 105.700006 41.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 108.718815 42.425745) (end 106.525751 42.425745) (width 0.25) (layer B.Cu) (net 41) (status 10)) + (segment (start 106.525751 42.425745) (end 105.900005 41.799999) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 105.900005 41.799999) (end 105.700006 41.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 107.9 78.6) (end 108.35 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 113.35 78.6) (end 114 79.25) (width 0.25) (layer B.Cu) (net 41)) + (via (at 114 79.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 107.9 78.6) (end 113.35 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.5 78.6) (end 107.9 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.5 73.95) (end 110.5 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 108.718815 42.425745) (end 110.970095 44.677025) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.970095 73.479905) (end 110.5 73.95) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.970095 44.677025) (end 110.970095 73.479905) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 107.95 85.625) (end 109.125 85.625) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 109.125 85.625) (end 112.475 85.625) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 109.374996 87.375) (end 109.4 87.400004) (width 0.25) (layer F.Cu) (net 41)) + (via (at 109.4 87.400004) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 107.95 87.375) (end 109.374996 87.375) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 109.4 85.625) (end 109.4 87.400004) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 109.125 85.625) (end 109.4 85.625) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 113.3435 83.30438) (end 112.522 83.30438) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 114 82.64788) (end 113.3435 83.30438) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 114 79.25) (end 114 82.64788) (width 0.25) (layer F.Cu) (net 41)) + (via (at 112.475 85.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 112.522 85.578) (end 112.475 85.625) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 112.522 83.30438) (end 112.522 85.578) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 91.587307 53.93) (end 92.18 53.93) (width 0.25) (layer F.Cu) (net 42) (status 30)) + (segment (start 101.6 68.69962) (end 101.7 68.79962) (width 0.25) (layer B.Cu) (net 42) (status 30)) + (segment (start 92.18 53.93) (end 101.7 53.93) (width 0.25) (layer F.Cu) (net 42) (status 10)) + (via (at 101.2 53.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 42)) + (segment (start 105.430018 53.93) (end 101.7 53.93) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 105.700018 54.2) (end 105.430018 53.93) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 106.625763 55.125745) (end 105.900017 54.399999) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 101.2 68.79962) (end 101.2 53.93) (width 0.25) (layer B.Cu) (net 42) (status 10)) + (segment (start 108.718815 55.125745) (end 106.625763 55.125745) (width 0.25) (layer B.Cu) (net 42) (status 10)) + (segment (start 105.900017 54.399999) (end 105.700018 54.2) (width 0.25) (layer B.Cu) (net 42)) + (via (at 105.700018 54.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 42)) + (segment (start 102.796902 68.79962) (end 102.826022 68.7705) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 101.7 68.79962) (end 102.796902 68.79962) (width 0.25) (layer B.Cu) (net 42)) + (via (at 102.826022 68.7705) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 42)) + (segment (start 101.346 68.7705) (end 102.826022 68.7705) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 100.579272 78.061965) (end 100.579272 69.537228) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 100.579272 69.537228) (end 101.346 68.7705) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 99.413 68.1) (end 102.438364 68.1) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 102.826022 68.487658) (end 102.826022 68.7705) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 102.438364 68.1) (end 102.826022 68.487658) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 99.2 68.79962) (end 99.2 68.313) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 99.2 68.313) (end 99.413 68.1) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 107.46 46.2) (end 107.47 46.21) (width 0.25) (layer F.Cu) (net 43) (status 30)) + (segment (start 105.7 46.2) (end 107.46 46.2) (width 0.25) (layer F.Cu) (net 43) (status 20)) + (segment (start 104.394255 47.505745) (end 105.7 46.2) (width 0.25) (layer F.Cu) (net 43)) + (segment (start 93.478815 47.505745) (end 104.394255 47.505745) (width 0.25) (layer F.Cu) (net 43) (status 10)) + (segment (start 89.000001 79.750001) (end 90 80.75) (width 0.25) (layer B.Cu) (net 43) (status 20)) + (segment (start 88.674999 79.424999) (end 89.000001 79.750001) (width 0.25) (layer B.Cu) (net 43)) + (segment (start 88.674999 50.746239) (end 88.674999 79.424999) (width 0.25) (layer B.Cu) (net 43)) + (segment (start 91.658239 47.762999) (end 88.674999 50.746239) (width 0.25) (layer B.Cu) (net 43)) + (segment (start 93.221561 47.762999) (end 91.658239 47.762999) (width 0.25) (layer B.Cu) (net 43) (status 10)) + (segment (start 93.478815 47.505745) (end 93.221561 47.762999) (width 0.25) (layer B.Cu) (net 43) (status 30)) + (via (at 143.3178 131.8262) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 129.7796 122.098) (end 129.7796 127.4828) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 143.3178 131.8262) (end 134.123 131.8262) (width 0.25) (layer F.Cu) (net 44)) + (via (at 132.6244 130.3276) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 134.123 131.8262) (end 132.6244 130.3276) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 129.7796 127.4828) (end 132.6244 130.3276) (width 0.25) (layer B.Cu) (net 44)) + (via (at 157.491 128.82899) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 165.6 125.12) (end 161.86149 128.85851) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 157.52052 128.85851) (end 157.491 128.82899) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 146.31501 128.82899) (end 157.491 128.82899) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 143.3178 131.8262) (end 146.31501 128.82899) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 154.86399 128.82899) (end 157.491 128.82899) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 151.6 125.565) (end 154.86399 128.82899) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 151.6 123.87) (end 151.6 125.565) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 165.6 123.87) (end 165.6 125.12) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 161.86149 128.85851) (end 157.52052 128.85851) (width 0.25) (layer B.Cu) (net 44)) + (via (at 129.7796 122.098) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 127.55 121.6) (end 129.2816 121.6) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 129.2816 121.6) (end 129.7796 122.098) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 129.7796 122.098) (end 129.2816 121.6) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 129.2816 121.6) (end 127.55 121.6) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 106.224255 42.425745) (end 107.42 41.23) (width 0.25) (layer F.Cu) (net 45) (status 20)) + (segment (start 93.478815 42.425745) (end 106.224255 42.425745) (width 0.25) (layer F.Cu) (net 45) (status 10)) + (segment (start 92.18 56.47) (end 105.469992 56.47) (width 0.25) (layer F.Cu) (net 46) (status 10)) + (segment (start 105.469992 56.47) (end 105.499993 56.500001) (width 0.25) (layer F.Cu) (net 46)) + (segment (start 106.665737 57.665745) (end 105.899991 56.899999) (width 0.25) (layer B.Cu) (net 46)) + (segment (start 105.499993 56.500001) (end 105.699992 56.7) (width 0.25) (layer F.Cu) (net 46)) + (segment (start 105.899991 56.899999) (end 105.699992 56.7) (width 0.25) (layer B.Cu) (net 46)) + (segment (start 108.718815 57.665745) (end 106.665737 57.665745) (width 0.25) (layer B.Cu) (net 46) (status 10)) + (via (at 105.699992 56.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 46)) + (via (at 94.8 70.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 47)) + (segment (start 92.18 43.77) (end 94.7 43.77) (width 0.25) (layer F.Cu) (net 47) (status 10)) + (segment (start 94.7 43.77) (end 94.97 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 105.47 43.77) (end 105.500001 43.800001) (width 0.25) (layer F.Cu) (net 47)) + (via (at 95.1 44.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 47)) + (segment (start 106.665745 44.965745) (end 105.899999 44.199999) (width 0.25) (layer B.Cu) (net 47)) + (segment (start 105.500001 43.800001) (end 105.7 44) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.1 44.2) (end 94.8 44.5) (width 0.25) (layer B.Cu) (net 47)) + (via (at 105.7 44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 47)) + (segment (start 105.899999 44.199999) (end 105.7 44) (width 0.25) (layer B.Cu) (net 47)) + (segment (start 108.718815 44.965745) (end 106.665745 44.965745) (width 0.25) (layer B.Cu) (net 47) (status 10)) + (segment (start 94.8 44.5) (end 94.8 70.6) (width 0.25) (layer B.Cu) (net 47)) + (segment (start 94.254 74.49962) (end 94 74.49962) (width 0.25) (layer F.Cu) (net 47) (status 30)) + (segment (start 94.8215 73.93212) (end 94.254 74.49962) (width 0.25) (layer F.Cu) (net 47) (status 20)) + (segment (start 94.8215 73.72112) (end 94.8215 73.93212) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 94.8 73.69962) (end 94.8215 73.72112) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 94.8 70.6) (end 94.8 73.69962) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.1 43.792) (end 95.078 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.1 44.2) (end 95.1 43.792) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 94.7 43.77) (end 95.078 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.078 43.77) (end 105.47 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 96.7 69.80038) (end 96.7 74.6) (width 0.25) (layer F.Cu) (net 48) (status 30)) + (segment (start 96.7 69.80038) (end 96.7 74.6) (width 0.25) (layer B.Cu) (net 48) (status 30)) + (segment (start 99.2 74.56) (end 99.24 74.6) (width 0.25) (layer F.Cu) (net 49) (status 30)) + (segment (start 99.2 69.80038) (end 99.2 74.56) (width 0.25) (layer F.Cu) (net 49) (status 30)) + (segment (start 99.2 74.56) (end 99.24 74.6) (width 0.25) (layer B.Cu) (net 49) (status 30)) + (segment (start 99.2 69.80038) (end 99.2 74.56) (width 0.25) (layer B.Cu) (net 49) (status 30)) + (segment (start 101.7 74.52) (end 101.78 74.6) (width 0.25) (layer F.Cu) (net 50) (status 30)) + (segment (start 101.7 69.80038) (end 101.7 74.52) (width 0.25) (layer F.Cu) (net 50) (status 30)) + (segment (start 101.7 74.52) (end 101.78 74.6) (width 0.25) (layer B.Cu) (net 50) (status 30)) + (segment (start 101.7 69.80038) (end 101.7 74.52) (width 0.25) (layer B.Cu) (net 50) (status 30)) + (segment (start 104.3 74.58) (end 104.32 74.6) (width 0.25) (layer F.Cu) (net 51) (status 30)) + (segment (start 104.3 69.80038) (end 104.3 74.58) (width 0.25) (layer F.Cu) (net 51) (status 30)) + (segment (start 104.3 74.58) (end 104.32 74.6) (width 0.25) (layer B.Cu) (net 51) (status 30)) + (segment (start 104.3 69.80038) (end 104.3 74.58) (width 0.25) (layer B.Cu) (net 51) (status 30)) + (segment (start 180.607 131.623) (end 178.065 131.623) (width 0.25) (layer B.Cu) (net 52)) + (via (at 178.065 131.623) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 52)) + (segment (start 184.6 126.38) (end 184.6 127.63) (width 0.25) (layer B.Cu) (net 52)) + (segment (start 184.6 127.63) (end 180.607 131.623) (width 0.25) (layer B.Cu) (net 52)) + (via (at 128.6828 119.02) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 52)) + (segment (start 170.6 128.4995) (end 170.6 126.38) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 178.065 131.623) (end 173.7235 131.623) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 173.7235 131.623) (end 170.6 128.4995) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 170.6 128.5485) (end 169.794499 129.354001) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 170.6 126.38) (end 170.6 128.5485) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 169.794499 129.354001) (end 154.064003 129.354001) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 154.064003 129.354001) (end 145.614202 120.9042) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 145.614202 120.9042) (end 130.567 120.9042) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 130.567 120.9042) (end 128.6828 119.02) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 127.58 119.02) (end 128.6828 119.02) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 128.6828 119.02) (end 127.58 119.02) (width 0.25) (layer B.Cu) (net 52)) + (segment (start 108.55 97) (end 108.7 97) (width 0.25) (layer B.Cu) (net 53) (status 30)) + (segment (start 107 98.55) (end 107 102) (width 0.25) (layer B.Cu) (net 53) (status 20)) + (segment (start 108.55 97) (end 107.775 97.775) (width 0.25) (layer F.Cu) (net 53)) + (segment (start 108.775 97) (end 108.55 97) (width 0.25) (layer F.Cu) (net 53)) + (segment (start 107 98.55) (end 107.775 97.775) (width 0.25) (layer B.Cu) (net 53)) + (via (at 107.775 97.775) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 53)) + (segment (start 107.775 97.775) (end 108.55 97) (width 0.25) (layer B.Cu) (net 53)) + (segment (start 114.55 55.12) (end 114.57 55.12) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 125.55 95.6) (end 125.55 94.27) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC2)) + (segment (start 125.55 94.27) (end 126.45 93.37) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC3)) + (segment (start 115.05 93.37) (end 115.07 93.37) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 115.07 93.37) (end 117.3 95.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC5)) + (segment (start 117.3 95.6) (end 125.55 95.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC6)) + (via (at 125.55 95.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54) (tstamp 5F754BC8)) + (segment (start 125.3 76.6) (end 125.3 75.27) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC2)) + (segment (start 125.3 75.27) (end 126.2 74.37) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC3)) + (segment (start 114.8 74.37) (end 114.82 74.37) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 114.82 74.37) (end 117.05 76.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC5)) + (segment (start 117.05 76.6) (end 125.3 76.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC6)) + (via (at 125.3 76.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54) (tstamp 5F754BC8)) + (segment (start 125.3 114.45) (end 125.3 113.12) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC2)) + (segment (start 125.3 113.12) (end 126.2 112.22) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC3)) + (segment (start 114.8 112.22) (end 114.82 112.22) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 114.82 112.22) (end 117.05 114.45) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC5)) + (segment (start 117.05 114.45) (end 125.3 114.45) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC6)) + (via (at 125.3 114.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54) (tstamp 5F754BC8)) + (segment (start 95.3 67.280659) (end 96.130626 66.450033) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 106.658001 68.408001) (end 107.42 69.17) (width 0.25) (layer F.Cu) (net 54) (status 20)) + (segment (start 93.478815 70.365745) (end 95.3 68.54456) (width 0.25) (layer F.Cu) (net 54) (status 10)) + (segment (start 95.3 68.54456) (end 95.3 67.280659) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 96.130626 66.450033) (end 103.963219 66.450033) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 103.963219 66.450033) (end 105.921187 68.408001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 105.921187 68.408001) (end 106.658001 68.408001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.825 110.325) (end 111 110.5) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 107 107) (end 109.5 107) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 109.5 107) (end 110.825 105.675) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 105.675) (end 110.825 110.325) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 112.405 90.825) (end 110.825 90.825) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.8 93.22) (end 112.405 90.825) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 90.825) (end 110.825 105.675) (width 0.25) (layer B.Cu) (net 54)) + (via (at 114.75 56.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 114.75 55.17) (end 114.8 55.12) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.75 56.5) (end 114.75 55.17) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 89.79999) (end 110.77501 89.75) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 90.825) (end 110.825 89.79999) (width 0.25) (layer B.Cu) (net 54)) + (via (at 110.77501 89.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (via (at 111.75 112.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111 110.5) (end 111 111.5) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 111 111.5) (end 111.75 112.25) (width 0.25) (layer B.Cu) (net 54)) + (via (at 114.25 113.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.75 112.25) (end 113.25 113.75) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 113.25 113.75) (end 114.25 113.75) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 114.25 112.77) (end 114.8 112.22) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.25 113.75) (end 114.25 112.77) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 111.644437 71.064437) (end 111.644437 69.155563) (width 0.25) (layer B.Cu) (net 54)) + (via (at 111.649995 69.150005) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.644437 69.155563) (end 111.649995 69.150005) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.490724 69.150005) (end 110.445094 69.104375) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 111.649995 69.150005) (end 110.490724 69.150005) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 107.42 69.17) (end 110.379469 69.17) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.379469 69.17) (end 110.445094 69.104375) (width 0.25) (layer B.Cu) (net 54)) + (via (at 110.445094 69.104375) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.644437 74.22) (end 111.644437 71.064437) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.8 74.22) (end 111.644437 74.22) (width 0.25) (layer B.Cu) (net 54)) + (via (at 111.2 74.35) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.33 74.22) (end 111.2 74.35) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 111.644437 74.22) (end 111.33 74.22) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.75 56.905001) (end 114.75 56.5) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 126.2 55.12) (end 124.414999 56.905001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 124.414999 56.905001) (end 114.75 56.905001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 114.75 56.9) (end 114.75 56.5) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 112.1 59.55) (end 114.75 56.9) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 111.649995 69.150005) (end 111.649995 64.550005) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 111.649995 64.550005) (end 112.1 64.1) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 112.1 64.1) (end 112.1 59.55) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.77501 89.75) (end 110.975009 89.550001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.77501 74.77499) (end 111.2 74.35) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.77501 85.825184) (end 110.77501 74.77499) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.975009 86.025183) (end 110.77501 85.825184) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.975009 89.550001) (end 110.975009 86.025183) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 106.224255 55.125745) (end 107.42 53.93) (width 0.25) (layer F.Cu) (net 55) (status 20)) + (segment (start 93.478815 55.125745) (end 98.374255 55.125745) (width 0.25) (layer F.Cu) (net 55) (status 10)) + (segment (start 98.874255 55.125745) (end 101.874255 55.125745) (width 0.25) (layer F.Cu) (net 55) (tstamp 5D8DA161)) + (segment (start 101.874255 55.125745) (end 106.224255 55.125745) (width 0.25) (layer F.Cu) (net 55) (tstamp 5D8DA17D)) + (via (at 101.874255 55.125745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 55)) + (segment (start 98.374255 55.125745) (end 98.874255 55.125745) (width 0.25) (layer F.Cu) (net 55) (tstamp 5D8DA43A)) + (segment (start 104.82499 75.609792) (end 104.82499 84.838178) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.2 73.965218) (end 105.343501 74.108719) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.2 68.225618) (end 105.2 73.965218) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.29999 89.83642) (end 93.825001 101.311409) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 101.874255 55.125745) (end 101.874255 64.899873) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 93.825001 101.311409) (end 93.825001 105.674999) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 93.499999 106.000001) (end 92.5 107) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.343501 74.108719) (end 105.343501 75.091281) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.29999 85.313178) (end 105.29999 89.83642) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.343501 75.091281) (end 104.82499 75.609792) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 101.874255 64.899873) (end 105.2 68.225618) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 104.82499 84.838178) (end 105.29999 85.313178) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 93.825001 105.674999) (end 93.499999 106.000001) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 106.224255 52.585745) (end 107.42 51.39) (width 0.25) (layer F.Cu) (net 56) (status 20)) + (segment (start 93.478815 52.585745) (end 98.514255 52.585745) (width 0.25) (layer F.Cu) (net 56) (status 10)) + (segment (start 98.514255 52.585745) (end 106.224255 52.585745) (width 0.25) (layer F.Cu) (net 56) (tstamp 5D8DA43D)) + (via (at 98.514255 52.585745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 56)) + (segment (start 93.499999 101.000001) (end 92.5 102) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 101.37501 93.12499) (end 93.499999 101.000001) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.514255 52.868587) (end 98.216499 53.166343) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.514255 52.585745) (end 98.514255 52.868587) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.216499 53.166343) (end 98.216499 81.404784) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 101.37501 84.563295) (end 101.37501 93.12499) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.216499 81.404784) (end 101.37501 84.563295) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 102.3 80.7) (end 102.7 80.3) (width 0.25) (layer F.Cu) (net 57) (status 30)) + (segment (start 100.2 85.3) (end 99.8 85.3) (width 0.25) (layer B.Cu) (net 57) (status 30)) + (segment (start 100.2 85.3) (end 99.8 85.3) (width 0.25) (layer F.Cu) (net 57) (status 30)) + (segment (start 102.7 82.8) (end 100.2 85.3) (width 0.25) (layer F.Cu) (net 57) (status 20)) + (segment (start 102.7 80.3) (end 102.7 82.8) (width 0.25) (layer F.Cu) (net 57) (status 10)) + (segment (start 99.8 85.3) (end 99.8 87.75) (width 0.25) (layer F.Cu) (net 57) (status 30)) + (segment (start 94 81.25) (end 91.7 83.55) (width 0.25) (layer F.Cu) (net 58) (status 20)) + (segment (start 94 75.50038) (end 94 81.25) (width 0.25) (layer F.Cu) (net 58) (status 10)) + (segment (start 91.3 83.55) (end 91.3 89.5) (width 0.25) (layer F.Cu) (net 58) (status 30)) + (segment (start 91.7 83.55) (end 91.3 83.55) (width 0.25) (layer F.Cu) (net 58) (status 30)) + (segment (start 92.87501 82.37499) (end 91.7 83.55) (width 0.25) (layer F.Cu) (net 58) (status 20)) + (segment (start 100.031029 82.37499) (end 92.87501 82.37499) (width 0.25) (layer F.Cu) (net 58)) + (segment (start 101.602773 80.803246) (end 100.031029 82.37499) (width 0.25) (layer F.Cu) (net 58)) + (segment (start 101.602773 79.197227) (end 101.602773 80.803246) (width 0.25) (layer F.Cu) (net 58)) + (segment (start 102.7 78.1) (end 101.602773 79.197227) (width 0.25) (layer F.Cu) (net 58) (status 10)) + (via (at 117.5 87.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 117.5 87.5) (end 114.999994 84.999994) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 114.999994 84.999994) (end 114.999994 83.8) (width 0.25) (layer B.Cu) (net 59)) + (via (at 114.999994 83.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 122.7 60.375) (end 122.125 60.375) (width 0.25) (layer F.Cu) (net 59)) + (via (at 124.6 59.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 122.7 60.375) (end 123.725 60.375) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 123.725 60.375) (end 124.6 59.5) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 124.6 59.5) (end 124.15 59.05) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 123.125 59.05) (end 122.7 58.625) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 124.15 59.05) (end 123.125 59.05) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 118 67.7) (end 119.25 66.45) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 114.999994 81.667164) (end 120.25 76.417158) (width 0.25) (layer F.Cu) (net 59)) + (via (at 122.25 66.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 114.999994 83.8) (end 114.999994 81.667164) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 120.25 72.365002) (end 118 70.115002) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 119.25 66.45) (end 122.25 66.45) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 118 70.115002) (end 118 67.7) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 120.25 76.417158) (end 120.25 72.365002) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.05 123.255) (end 111.245 123.255) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 110.261732 123.255) (end 109.4 124.116732) (width 0.25) (layer B.Cu) (net 59)) + (via (at 109.4 124.116732) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 111.05 123.255) (end 110.261732 123.255) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 109.616732 124.116732) (end 109.4 124.116732) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.05 125.005) (end 110.505 125.005) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 110.505 125.005) (end 109.616732 124.116732) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 125.163188 59.5) (end 124.6 59.5) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 125.9 60.236812) (end 125.163188 59.5) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 122.25 66.45) (end 123.339998 66.45) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 125.9 63.889998) (end 125.9 60.236812) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 123.339998 66.45) (end 125.9 63.889998) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 119.785001 94.414997) (end 115.7605 98.439498) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 117.645024 114.779997) (end 112.9 119.525021) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.05 123.255) (end 110.459998 122.664998) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 117.5 88.815) (end 119.785001 91.100001) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 117.175001 107.424) (end 119.785001 110.034) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 119.785001 114.779997) (end 117.645024 114.779997) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 117.175001 105.4746) (end 117.175001 107.424) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.574979 119.525021) (end 112.9 119.525021) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 119.785001 91.100001) (end 119.785001 94.414997) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 115.7605 104.060099) (end 117.175001 105.4746) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 110.459998 120.640002) (end 111.574979 119.525021) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 119.785001 110.034) (end 119.785001 114.779997) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 110.459998 122.664998) (end 110.459998 120.640002) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 115.7605 98.439498) (end 115.7605 104.060099) (width 0.25) (layer F.Cu) (net 59)) + (via (at 112.9 119.525021) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 117.5 87.5) (end 117.5 88.815) (width 0.25) (layer F.Cu) (net 59)) + (via (at 154.5 53.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (segment (start 154.5 53.79) (end 151.5 53.79) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 151.5 53.79) (end 149.25 56.04) (width 0.25) (layer B.Cu) (net 60)) + (via (at 149.25 55.94) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (via (at 146.5 57.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (via (at 116.6 59.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (segment (start 118.3 58.625) (end 117.675 58.625) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 117.675 58.625) (end 116.6 59.7) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 147.89 57.3) (end 149.25 55.94) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 146.5 57.3) (end 147.89 57.3) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 154.94 54.6735) (end 156.2915 54.6735) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 154.5 53.79) (end 154.5 54.2335) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 156.2915 54.6735) (end 156.3 54.665) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 154.5 54.2335) (end 154.94 54.6735) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 156.3 52.915) (end 154.984 52.915) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 154.5 53.399) (end 154.5 53.79) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 154.984 52.915) (end 154.5 53.399) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 118.25 60.325) (end 118.3 60.375) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 116.967 60.325) (end 118.25 60.325) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 116.6 59.7) (end 116.6 59.958) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 116.6 59.958) (end 116.967 60.325) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 118.864998 60.375) (end 118.3 60.375) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 126 57) (end 125.4 57.6) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 126 56) (end 126 57) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 131.5 54) (end 128 54) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 121.639998 57.6) (end 118.864998 60.375) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 134.8 57.3) (end 131.5 54) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 128 54) (end 126 56) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 125.4 57.6) (end 121.639998 57.6) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 146.5 57.3) (end 134.8 57.3) (width 0.25) (layer B.Cu) (net 60)) + (via (at 159 53.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (via (at 165.750003 56.789997) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 160.7 54.665) (end 162.575 54.665) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 162.575 54.665) (end 162.65 54.59) (width 0.25) (layer F.Cu) (net 61)) + (via (at 162.65 54.59) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 199.7 60.375) (end 199.025 60.375) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 199.7 62.125) (end 199.225 62.125) (width 0.25) (layer F.Cu) (net 61)) + (via (at 201.4 61.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 201.4 60.7475) (end 201.4 61.25) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 199.7 60.375) (end 201.0275 60.375) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 201.0275 60.375) (end 201.4 60.7475) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 199.7 62.125) (end 198.015 62.125) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 168.421606 59.4616) (end 165.750003 56.789997) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 174.436814 63.65) (end 170.248414 59.4616) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 170.248414 59.4616) (end 168.421606 59.4616) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 189.336812 63.65) (end 174.436814 63.65) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 163.550006 54.59) (end 162.65 54.59) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 165.750003 56.789997) (end 163.550006 54.59) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 160.6915 54.6735) (end 160.7 54.665) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159.4485 54.6735) (end 160.6915 54.6735) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159 53.79) (end 159 54.225) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159 54.225) (end 159.4485 54.6735) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159 53.344) (end 159 53.79) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 160.7 52.915) (end 159.429 52.915) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 159.429 52.915) (end 159 53.344) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 200.892 62.125) (end 199.7 62.125) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 201.4 61.25) (end 201.4 61.617) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 201.4 61.617) (end 200.892 62.125) (width 0.25) (layer F.Cu) (net 61)) + (via (at 189.336812 63.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 189.3086 63.65) (end 189.336812 63.65) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 189.336812 63.65) (end 189.334 63.65) (width 0.25) (layer B.Cu) (net 61)) + (via (at 191.475 63.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 189.359 63.625) (end 191.475 63.625) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 189.334 63.65) (end 189.359 63.625) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 192.293822 61.273992) (end 197.163992 61.273992) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 197.163992 61.273992) (end 198.015 62.125) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 191.475 62.092814) (end 192.293822 61.273992) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 191.475 63.625) (end 191.475 62.092814) (width 0.25) (layer F.Cu) (net 61)) + (via (at 102.74 125.6775) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 151.2836 119.1376) (end 151.8154 119.1376) (width 0.25) (layer F.Cu) (net 62)) + (via (at 152.8174 118.1356) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 151.8154 119.1376) (end 152.8174 118.1356) (width 0.25) (layer F.Cu) (net 62)) + (via (at 148.347 122.121502) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 141.875001 124.840001) (end 141.875001 123.870999) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 143.624498 122.121502) (end 148.347 122.121502) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 140.214999 130.026801) (end 140.214999 126.500003) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 149.896896 119.1376) (end 148.347 120.687496) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 140.214999 126.500003) (end 141.875001 124.840001) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 151.2836 119.1376) (end 149.896896 119.1376) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 141.875001 123.870999) (end 143.624498 122.121502) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 148.347 120.687496) (end 148.347 122.121502) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 152.5031 117.3876) (end 151.2836 117.3876) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 152.8174 118.1356) (end 152.8174 117.7019) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 152.8174 117.7019) (end 152.5031 117.3876) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 140.214999 130.026801) (end 137.7418 132.5) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 137.7418 132.5) (end 131.024079 132.5) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 131.024079 132.5) (end 126.9 132.5) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 122.990613 136.409387) (end 111.690613 136.409387) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 126.9 132.5) (end 122.990613 136.409387) (width 0.25) (layer B.Cu) (net 62)) + (via (at 108.3 132) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 111.690613 136.409387) (end 108.3 133.018774) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 108.3 133.018774) (end 108.3 132) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 104.945 123.255) (end 106.65 123.255) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 102.74 125.6775) (end 102.74 125.46) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 102.74 125.46) (end 104.945 123.255) (width 0.25) (layer F.Cu) (net 62)) + (via (at 106.06801 126.351315) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 106.06801 129.76801) (end 106.06801 126.351315) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 108.3 132) (end 106.06801 129.76801) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 102.74 125.74) (end 102.74 125.6775) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 103.4 126.4) (end 102.74 125.74) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 105.255 126.4) (end 103.4 126.4) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 106.06801 125.58699) (end 106.65 125.005) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 106.65 125.005) (end 105.6675 125.9875) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 105.704195 125.9875) (end 105.6675 125.9875) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 105.6675 125.9875) (end 105.255 126.4) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 106.06801 126.351315) (end 105.704195 125.9875) (width 0.25) (layer B.Cu) (net 62)) + (via (at 188.822468 120.130068) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 63)) + (segment (start 187.25 121.195) (end 187.757536 121.195) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 187.757536 121.195) (end 188.822468 120.130068) (width 0.25) (layer F.Cu) (net 63)) + (via (at 145.2228 118.2118) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 63)) + (segment (start 146.8836 119.1376) (end 146.1486 119.1376) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 146.1486 119.1376) (end 145.2228 118.2118) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 145.2228 118.2118) (end 145.2228 117.653) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 145.4882 117.3876) (end 146.8836 117.3876) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 145.2228 117.653) (end 145.4882 117.3876) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 188.5315 119.4435) (end 187.2515 119.4435) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 187.2515 119.4435) (end 187.25 119.445) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 188.822468 120.130068) (end 188.822468 119.734468) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 188.822468 119.734468) (end 188.5315 119.4435) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 188.822468 120.130068) (end 186.427537 122.524999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 186.427537 122.524999) (end 179.840001 122.524999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 173.5692 121.3868) (end 171.097399 118.914999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 146.8836 119.1376) (end 148.9191 119.1376) (width 0.25) (layer B.Cu) (net 63)) + (via (at 149.7965 120.015) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 63)) + (segment (start 178.701802 121.3868) (end 173.5692 121.3868) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 148.9191 119.1376) (end 149.7965 120.015) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 153.5034 120.015) (end 149.7965 120.015) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 171.097399 118.914999) (end 154.603401 118.914999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 179.840001 122.524999) (end 178.701802 121.3868) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 154.603401 118.914999) (end 153.5034 120.015) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 195.3 60.375) (end 195.19999 60.27499) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 195.3 62.125) (end 195.875001 62.125) (width 0.25) (layer B.Cu) (net 64)) + (via (at 190.95 61.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 195.3 60.375) (end 191.975 60.375) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 191.975 60.375) (end 190.95 61.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 190.95 64.427002) (end 190.95 61.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.25 67.722998) (end 187.997999 66.974999) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 188.402003 66.974999) (end 190.95 64.427002) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.997999 66.974999) (end 188.402003 66.974999) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 192.034 62.484) (end 190.95 61.4) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 195.3 62.125) (end 194.941 62.484) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 194.941 62.484) (end 192.034 62.484) (width 0.25) (layer B.Cu) (net 64)) + (via (at 111.403027 84.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 111.412999 84.240028) (end 111.403027 84.25) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 112.5 80.5) (end 111.412999 81.587001) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 111.403027 84.25) (end 108.55 84.25) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 181.5 94.65) (end 172.75 94.65) (width 0.25) (layer B.Cu) (net 64)) + (via (at 170 94.675) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 172.75 94.65) (end 170.025 94.65) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 170.025 94.65) (end 170 94.675) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 170 94.675) (end 168.975 93.65) (width 0.25) (layer F.Cu) (net 64)) + (via (at 168.75 93.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 168.975 93.65) (end 168.775 93.65) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 168.775 93.65) (end 168.75 93.625) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 168.725 93.65) (end 168.75 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 103.67005 86.50495) (end 104.704243 86.50495) (width 0.25) (layer B.Cu) (net 64)) + (via (at 104.704243 86.50495) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 103.55 87.375) (end 103.55 86.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 103.55 86.625) (end 103.67005 86.50495) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 108.55 84.25) (end 108.5 84.25) (width 0.25) (layer B.Cu) (net 64) (tstamp 5FDB7154)) + (via (at 108.55 84.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 103.55 85.625) (end 103.55 84.8375) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 107.65 83.4) (end 108.5 84.25) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 104.9875 83.4) (end 107.65 83.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 103.55 84.8375) (end 104.9875 83.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 104.704243 86.304243) (end 104.704243 86.50495) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 103.55 85.625) (end 104.025 85.625) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 104.025 85.625) (end 104.704243 86.304243) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 111.412999 81.587001) (end 111.412999 82.389001) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 111.412999 82.389001) (end 111.412999 84.240028) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 112.522 80.522) (end 112.5 80.5) (width 0.25) (layer F.Cu) (net 64)) + (via (at 112.5 80.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 112.522 82.30362) (end 112.522 80.522) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 185.474999 98.809421) (end 185.4454 98.83902) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.25 86.65) (end 185.474999 88.425001) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.25 67.622998) (end 187.25 86.65) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 183.213401 96.363401) (end 185.474999 96.363401) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 181.5 94.65) (end 183.213401 96.363401) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 185.474999 96.363401) (end 185.474999 98.809421) (width 0.25) (layer F.Cu) (net 64)) + (via (at 185.474999 96.363401) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 185.474999 88.425001) (end 185.474999 96.363401) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 168.467158 93.625) (end 168.75 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 166.285 93.625) (end 168.467158 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 164.45 91.79) (end 166.285 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 129.95 90.35) (end 133.20001 93.60001) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 133.20001 93.60001) (end 148.70358 93.60001) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 153.42789 92.36791) (end 154.0058 91.79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 153.43978 92.3798) (end 153.42789 92.36791) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 112.5 80.5) (end 113.512 80.5) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 129.95 85.286) (end 129.95 90.35) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 148.70358 93.60001) (end 149.92379 92.3798) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 154.0058 91.79) (end 164.45 91.79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 123.664 79) (end 129.95 85.286) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 115.012 79) (end 123.664 79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 113.512 80.5) (end 115.012 79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 149.92379 92.3798) (end 153.43978 92.3798) (width 0.25) (layer B.Cu) (net 64)) + (via (at 143.240373 41.790373) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 65)) + (segment (start 117.8 45.375) (end 116.4 43.975) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 116.4 43.975) (end 116.4 43.45) (width 0.25) (layer F.Cu) (net 65)) + (via (at 116.4 43.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 65)) + (segment (start 118.1 45.375) (end 117.8 45.375) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 142.255746 42.775) (end 143.240373 41.790373) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 141.9 42.775) (end 142.255746 42.775) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 141.9 44.55) (end 141.9 42.775) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 141.45 45) (end 141.9 44.55) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 134.717 45) (end 141.45 45) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 118.2 41.65) (end 131.367 41.65) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 116.4 43.45) (end 118.2 41.65) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 131.367 41.65) (end 134.717 45) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 143.240373 41.360973) (end 143.240373 41.790373) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 141.9 41.025) (end 142.9044 41.025) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 142.9044 41.025) (end 143.240373 41.360973) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 118.1 43.625) (end 117.91 43.815) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 116.765 43.815) (end 116.4 43.45) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 117.91 43.815) (end 116.765 43.815) (width 0.25) (layer B.Cu) (net 65)) + (via (at 116.75 63.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 66)) + (segment (start 118.1 62.725) (end 117.775 62.725) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 117.775 62.725) (end 116.75 63.75) (width 0.25) (layer B.Cu) (net 66)) + (via (at 125.45 44.300002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 66)) + (segment (start 124.774998 43.625) (end 125.45 44.300002) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 122.9 45.375) (end 124.375002 45.375) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 124.375002 45.375) (end 125.45 44.300002) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 122.9 43.625) (end 124.774998 43.625) (width 0.25) (layer F.Cu) (net 66)) + (via (at 116.2 65.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 66)) + (segment (start 116.6905 64.475) (end 118.1 64.475) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.2 65.45) (end 116.2 64.9655) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.2 64.9655) (end 116.6905 64.475) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.75 64.4155) (end 116.6905 64.475) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.75 63.75) (end 116.75 64.4155) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 123.1879 45.375) (end 122.9 45.375) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 115.600001 57.799999) (end 118.450001 57.799999) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 118.450001 57.799999) (end 120 56.25) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 116.2 65.45) (end 115.22499 64.47499) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.85 46.0371) (end 123.1879 45.375) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 115.22499 58.17501) (end 115.600001 57.799999) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.824999 49.435999) (end 123.85 49.410998) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 115.22499 64.47499) (end 115.22499 58.17501) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.824999 50.190003) (end 123.824999 49.435999) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.85 49.410998) (end 123.85 46.0371) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 120 56.25) (end 120 54.015002) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 120 54.015002) (end 123.824999 50.190003) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 137.1 41.025) (end 136.425 41.025) (width 0.25) (layer B.Cu) (net 67)) + (via (at 135.55 41.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 67)) + (segment (start 136.425 41.025) (end 135.55 41.9) (width 0.25) (layer B.Cu) (net 67)) + (via (at 143.35 60.949994) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 67)) + (segment (start 142.424994 61.875) (end 143.35 60.949994) (width 0.25) (layer B.Cu) (net 67)) + (segment (start 141.9 61.875) (end 142.424994 61.875) (width 0.25) (layer B.Cu) (net 67)) + (segment (start 143.35 60.4825) (end 143.35 60.949994) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 142.9925 60.125) (end 143.35 60.4825) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 141.9 60.125) (end 142.9925 60.125) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 138.785001 50.200003) (end 138.785001 55.085001) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 136.425 42.775) (end 137.1 42.775) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 135.55 41.9) (end 136.425 42.775) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 137.1 42.775) (end 136.524998 43.350002) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 138.785001 55.085001) (end 141.9 58.2) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 136.524998 43.350002) (end 136.524998 47.94) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 141.9 58.2) (end 141.9 60.125) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 136.524998 47.94) (end 138.785001 50.200003) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 180 41.125) (end 179.775 41.125) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 180 42.875) (end 179.725 42.875) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 181.05 41.125) (end 182.75 42.825) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 180 41.125) (end 181.05 41.125) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 182.75 42.963186) (end 181.113186 44.6) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 182.75 42.825) (end 182.75 42.963186) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 181.113186 44.6) (end 180.25 44.6) (width 0.25) (layer F.Cu) (net 68)) + (via (at 180.25 44.599999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 68)) + (segment (start 180.25 44.6) (end 180.25 44.599999) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 180.25 43.125) (end 180 42.875) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 180.25 44.599999) (end 180.25 43.125) (width 0.25) (layer B.Cu) (net 68)) + (via (at 154.71924 39.40001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 68)) + (segment (start 154.71924 39.84774) (end 154.71924 39.40001) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.2 40.375) (end 155.2465 40.375) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 155.2465 40.375) (end 154.71924 39.84774) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 154.71924 39.01926) (end 154.71924 39.40001) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 156.2 38.625) (end 155.1135 38.625) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 155.1135 38.625) (end 154.71924 39.01926) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 162.415999 41.969199) (end 170.026722 41.969199) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 162.210209 42.174989) (end 162.415999 41.969199) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.4 42.174989) (end 162.210209 42.174989) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.2 41.974989) (end 156.4 42.174989) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.2 40.375) (end 156.2 41.974989) (width 0.25) (layer F.Cu) (net 68)) + (via (at 174.6 44.599999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 68)) + (segment (start 174.37124 44.371239) (end 174.6 44.599999) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 172.428761 44.371239) (end 174.37124 44.371239) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 170.026722 41.969199) (end 172.428761 44.371239) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 174.6 44.599999) (end 175.000001 45) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 179.849999 45) (end 180.25 44.599999) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 175.000001 45) (end 179.849999 45) (width 0.25) (layer B.Cu) (net 68)) + (via (at 154.75 58.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 69)) + (segment (start 156.2 57.715) (end 155.825 57.715) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 155.825 57.715) (end 154.75 58.79) (width 0.25) (layer B.Cu) (net 69)) + (via (at 162.500016 39.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 69)) + (segment (start 162.5 39.54) (end 162.500016 39.54) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 162 40.04) (end 162.5 39.54) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161 40.375) (end 161.335 40.04) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.335 40.04) (end 162 40.04) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.9 40.9325) (end 161.3425 40.375) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.9 45.215002) (end 161.9 40.9325) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 158.474999 48.640003) (end 161.9 45.215002) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.3425 40.375) (end 161 40.375) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 156.2 56.165) (end 156.575 55.79) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 156.2 57.715) (end 156.2 56.165) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 157.260002 55.79) (end 158.474999 54.575003) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 156.575 55.79) (end 157.260002 55.79) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 158.474999 54.575003) (end 158.474999 48.640003) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161 38.625) (end 162.0055 38.625) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 162.500016 39.119516) (end 162.500016 39.54) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 162.0055 38.625) (end 162.500016 39.119516) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 156.175 59.44) (end 156.2 59.465) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 155.1345 59.44) (end 156.175 59.44) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 154.75 58.79) (end 154.75 59.0555) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 154.75 59.0555) (end 155.1345 59.44) (width 0.25) (layer F.Cu) (net 69)) + (via (at 173 42.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 70)) + (segment (start 175.2 42.875) (end 173.725 42.875) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 173.725 42.875) (end 173 42.15) (width 0.25) (layer F.Cu) (net 70)) + (via (at 176.8005 50.3495) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 70)) + (segment (start 173.525 41.125) (end 175.2 41.125) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173 42.15) (end 173 41.65) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173 41.65) (end 173.525 41.125) (width 0.25) (layer B.Cu) (net 70)) + (via (at 181.549998 61.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 70)) + (segment (start 181.05 61.75) (end 181.549998 61.250002) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 181.549998 61.250002) (end 181.549998 61.1) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 180 61.875) (end 180.125 61.75) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 180.125 61.75) (end 181.05 61.75) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 180 58) (end 180 60.125) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 176.8005 50.3495) (end 178.314999 51.863999) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 178.314999 56.314999) (end 180 58) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 178.314999 51.863999) (end 178.314999 56.314999) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 181.242 61.1) (end 181.549998 61.1) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 180 60.125) (end 180.267 60.125) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 180.267 60.125) (end 181.242 61.1) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 175.224999 48.773998) (end 176.8005 50.3495) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 175.224999 46.024999) (end 175.224999 48.773998) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173.8 44.6) (end 175.224999 46.024999) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173 42.15) (end 173.8 42.95) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173.8 42.95) (end 173.8 44.6) (width 0.25) (layer B.Cu) (net 70)) + (via (at 192.8 46.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 193.054 46.75) (end 192.8 46.75) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 194.3 47.775) (end 194.079 47.775) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 194.079 47.775) (end 193.054 46.75) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.659 46.891) (end 192.659 47.909) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.8 46.75) (end 192.659 46.891) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.659 47.909) (end 194.3 49.55) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 194.3 49.55) (end 204.63641 49.55) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 204.63641 49.55) (end 206.91701 47.2694) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.8 46.341) (end 192.8 46.75) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 194.3 46.025) (end 193.116 46.025) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 193.116 46.025) (end 192.8 46.341) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 218.1 46.025) (end 218.62499 46.025) (width 0.25) (layer F.Cu) (net 71)) + (via (at 219.4 47) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 218.2 46.025) (end 218.425 46.025) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 218.425 46.025) (end 219.4 47) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 206.922609 47.274999) (end 206.91701 47.2694) (width 0.25) (layer F.Cu) (net 71)) + (via (at 218.4 44.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 218.4 45.825) (end 218.2 46.025) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 218.4 44.4) (end 218.4 45.825) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 218.425 47.775) (end 218.2 47.775) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 219.4 47) (end 219.2 47) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 219.2 47) (end 218.425 47.775) (width 0.25) (layer B.Cu) (net 71)) + (via (at 209.8 46.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 207.515708 46.6819) (end 206.922609 47.274999) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 209.3181 46.6819) (end 207.515708 46.6819) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 209.3181 46.6819) (end 209.8 46.2) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 211.799999 44.200001) (end 211.4898 44.5102) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 218.200001 44.200001) (end 211.799999 44.200001) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 218.4 44.4) (end 218.200001 44.200001) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 209.8 46.2) (end 211.4898 44.5102) (width 0.25) (layer B.Cu) (net 71)) + (via (at 200.75 47) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 72)) + (segment (start 194.3 64.925) (end 194.075 64.925) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 193 66.35) (end 193.25 66.6) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 193 66) (end 193 66.35) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 193.25 66.6) (end 194.225 66.6) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 194.225 66.6) (end 194.3 66.675) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 194.075 64.925) (end 193 66) (width 0.25) (layer B.Cu) (net 72)) + (via (at 193 66) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 72)) + (segment (start 200.75 46.445) (end 200.75 47) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 199.1 46.025) (end 200.33 46.025) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 200.33 46.025) (end 200.75 46.445) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 199.25 47.625) (end 199.1 47.775) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200.279 47.625) (end 199.25 47.625) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200.75 47) (end 200.75 47.154) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200.75 47.154) (end 200.279 47.625) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 197.275001 62.503499) (end 196.67849 63.10001) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200 48.362) (end 200 52.748998) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 197.275001 55.473997) (end 197.275001 62.503499) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 199.1 47.775) (end 199.413 47.775) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 199.413 47.775) (end 200 48.362) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200 52.748998) (end 197.275001 55.473997) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 194.834291 63.10001) (end 196.67849 63.10001) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 194.3 63.634301) (end 194.834291 63.10001) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 194.3 64.925) (end 194.3 63.634301) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 213.3 46.025) (end 212.974996 46.025) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 213.3 47.775) (end 212.775004 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.3 47.775) (end 213.3 47.8994) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.3 46.025) (end 212.9788 46.025) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 213.272 47.803) (end 213.3 47.775) (width 0.25) (layer F.Cu) (net 73)) + (via (at 219.5195 65.8495) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (segment (start 219.5195 66.2305) (end 219.5195 65.8495) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 218.1 66.675) (end 219.075 66.675) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 219.075 66.675) (end 219.5195 66.2305) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 219.5195 65.2145) (end 219.5195 65.8495) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 218.1 64.925) (end 219.23 64.925) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 219.23 64.925) (end 219.5195 65.2145) (width 0.25) (layer F.Cu) (net 73)) + (via (at 212 47) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (segment (start 213.4 46.025) (end 212.975 46.025) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 212.975 46.025) (end 212 47) (width 0.25) (layer B.Cu) (net 73)) + (via (at 212.8 50.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (via (at 212.8 49) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (segment (start 212.8 50.8) (end 212.8 49) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 212.8 49) (end 213.2 48.6) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.2 47.975) (end 213.4 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.2 48.6) (end 213.2 47.975) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.975 47.775) (end 213.4 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212 47) (end 212.2 47) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.2 47) (end 212.975 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 216.0888 57.5962) (end 216.0888 61.2888) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 214.659999 56.167399) (end 216.0888 57.5962) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 218.1 63.3) (end 218.1 64.925) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 216.0888 61.2888) (end 218.1 63.3) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 214.659999 54.775001) (end 214.659999 56.167399) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.8 52.915002) (end 214.659999 54.775001) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.8 50.8) (end 212.8 52.915002) (width 0.25) (layer F.Cu) (net 73)) + (via (at 116.275021 82.255755) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 116.275021 82.255755) (end 116.275021 81.174979) (width 0.25) (layer B.Cu) (net 74)) + (via (at 120.800002 79.525) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 116.275021 81.174979) (end 117.925 79.525) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 117.925 79.525) (end 120.800002 79.525) (width 0.25) (layer B.Cu) (net 74)) + (via (at 124.6 63.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 122.9 64.475) (end 123.575 64.475) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 123.575 64.475) (end 124.6 63.45) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 124.6 63.45) (end 123.95 62.8) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 122.975 62.8) (end 122.9 62.725) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 123.95 62.8) (end 122.975 62.8) (width 0.25) (layer F.Cu) (net 74)) + (via (at 122.923621 65.881628) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 122.9 65.858007) (end 122.923621 65.881628) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 122.9 64.475) (end 122.9 65.858007) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 122.875001 70.373997) (end 122.875001 65.930248) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 122.875001 65.930248) (end 122.923621 65.881628) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 120.800002 72.448996) (end 122.875001 70.373997) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 120.85 79.5) (end 120.800002 79.450002) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 120.800002 79.450002) (end 120.800002 72.448996) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 116.298276 82.2325) (end 116.275021 82.255755) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 118.1 81.725) (end 117.5925 82.2325) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 117.5925 82.2325) (end 116.298276 82.2325) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 118.1 83.475) (end 117.8285 83.475) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 116.609255 82.255755) (end 116.275021 82.255755) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 117.8285 83.475) (end 116.609255 82.255755) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 141.9 80.875) (end 142.675 80.875) (width 0.25) (layer B.Cu) (net 75)) + (segment (start 142.675 80.875) (end 143.65 79.9) (width 0.25) (layer B.Cu) (net 75)) + (via (at 143.65 79.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 75)) + (via (at 135.65 60.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 75)) + (segment (start 137.1 60.125) (end 136.475 60.125) (width 0.25) (layer B.Cu) (net 75)) + (segment (start 136.475 60.125) (end 135.65 60.95) (width 0.25) (layer B.Cu) (net 75)) + (segment (start 143.65 79.642) (end 143.65 79.9) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 141.9 76.65) (end 141.9 79.125) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 140.214999 74.964999) (end 141.9 76.65) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 136.575 61.875) (end 137.1 61.875) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 143.133 79.125) (end 143.65 79.642) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 135.65 60.95) (end 136.575 61.875) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 137.1 61.875) (end 137.1 67.615002) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 141.9 79.125) (end 143.133 79.125) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 137.1 67.615002) (end 140.214999 70.730001) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 140.214999 70.730001) (end 140.214999 74.964999) (width 0.25) (layer F.Cu) (net 75)) + (via (at 153.6 78.04) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 76)) + (segment (start 154.125 78.565) (end 153.6 78.04) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 156.2 78.565) (end 154.125 78.565) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 153.6 77.626812) (end 153.6 78.04) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 156.2 76.815) (end 154.411812 76.815) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 154.411812 76.815) (end 153.6 77.626812) (width 0.25) (layer B.Cu) (net 76)) + (via (at 162.3 58.74) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 76)) + (segment (start 161.275 57.715) (end 161 57.715) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 162.3 58.74) (end 161.275 57.715) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 163.55 60.14) (end 161.533999 62.156001) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 161.533999 64.756001) (end 159.314999 66.975001) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 161.533999 62.156001) (end 161.533999 64.756001) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 153.6 77.298312) (end 153.6 78.04) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 163.55 59.14) (end 163.55 60.14) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 162.3 58.74) (end 163.15 58.74) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 159.314999 71.583313) (end 153.6 77.298312) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 159.314999 66.975001) (end 159.314999 71.583313) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 163.15 58.74) (end 163.55 59.14) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 162.3 59.1372) (end 162.3 58.74) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 161 59.465) (end 161.9722 59.465) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 161.9722 59.465) (end 162.3 59.1372) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 175.2 61.875) (end 175.525 61.875) (width 0.25) (layer F.Cu) (net 77)) + (via (at 175 64.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 180 80.975) (end 180.925 80.975) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 180.925 80.975) (end 181.6 80.3) (width 0.25) (layer B.Cu) (net 77)) + (via (at 181.6 80.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 178.314999 70.730001) (end 175 67.415002) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 178.314999 75.564999) (end 178.314999 70.730001) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180 79.225) (end 180 77.25) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 175 67.415002) (end 175 64.65) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180 77.25) (end 178.314999 75.564999) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 175.2 60.125) (end 174.625 60.125) (width 0.25) (layer B.Cu) (net 77)) + (via (at 173.7 61.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 174.625 60.125) (end 173.7 61.05) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 173.7 61.05) (end 173.7 61.1) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 175.2 61.875) (end 175.2 63) (width 0.25) (layer F.Cu) (net 77)) + (via (at 175.15 63.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 175.2 63) (end 175.15 63.05) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 175.15 64.5) (end 175 64.65) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 175.15 63.05) (end 175.15 64.5) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 174.905 61.875) (end 175.2 61.875) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 173.7 61.1) (end 174.13 61.1) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 174.13 61.1) (end 174.905 61.875) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 181.392 80.3) (end 181.6 80.3) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180 79.225) (end 180.317 79.225) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180.317 79.225) (end 181.392 80.3) (width 0.25) (layer F.Cu) (net 77)) + (via (at 193.6 79.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 78)) + (segment (start 192.525 85.875) (end 191.75 85.1) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 191.75 81.65) (end 191.75 85.1) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 193.6 79.8) (end 191.75 81.65) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 194.3 85.875) (end 192.525 85.875) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 194.3 84.125) (end 192.725 84.125) (width 0.25) (layer B.Cu) (net 78)) + (via (at 191.75 85.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 78)) + (segment (start 192.725 84.125) (end 191.75 85.1) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.550014 64.925) (end 200.650004 66.02499) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 199.1 64.925) (end 199.550014 64.925) (width 0.25) (layer F.Cu) (net 78)) + (via (at 200.650004 66.02499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 78)) + (segment (start 195.985001 77.414999) (end 195.985001 75.663997) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 193.6 79.8) (end 195.985001 77.414999) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.1 67.7185) (end 199.1 66.675) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.9 68.5185) (end 199.1 67.7185) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.9 71.748998) (end 199.9 68.5185) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 195.985001 75.663997) (end 199.9 71.748998) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 200.650004 66.240496) (end 200.650004 66.02499) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.1 66.675) (end 200.2155 66.675) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 200.2155 66.675) (end 200.650004 66.240496) (width 0.25) (layer B.Cu) (net 78)) + (via (at 219.75 84.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 79)) + (segment (start 213.3 66.675) (end 212.675 66.675) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 218.1 84.125) (end 218.1 80.07499) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 218.1 80.07499) (end 216 77.97499) (width 0.25) (layer F.Cu) (net 79)) + (via (at 216 77.97499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 79)) + (via (at 210.951402 66.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 79)) + (segment (start 211.226402 66.675) (end 210.951402 66.95) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 213.3 64.925) (end 211.725 64.925) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 210.951402 65.698598) (end 210.951402 66.95) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 213 72.248999) (end 213 68.998598) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 213 68.998598) (end 210.951402 66.95) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 216 75.248999) (end 213 72.248999) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 216 77.97499) (end 216 75.248999) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 211.725 64.925) (end 210.951402 65.698598) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 213.3 66.675) (end 211.226402 66.675) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.202 84.201) (end 218.176 84.201) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 218.176 84.201) (end 218.1 84.125) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.75 84.75) (end 219.75 84.749) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.75 84.749) (end 219.202 84.201) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.75 85.304) (end 219.75 84.75) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 218.1 85.875) (end 219.179 85.875) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 219.179 85.875) (end 219.75 85.304) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 123.125 81.5) (end 122.9 81.725) (width 0.25) (layer F.Cu) (net 80)) + (via (at 116.975317 101.458646) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 80)) + (segment (start 117.366354 101.458646) (end 116.975317 101.458646) (width 0.25) (layer B.Cu) (net 80)) + (segment (start 118.1 100.725) (end 117.366354 101.458646) (width 0.25) (layer B.Cu) (net 80)) + (segment (start 125.425 83.475) (end 125.45 83.5) (width 0.25) (layer B.Cu) (net 80)) + (segment (start 122.9 83.475) (end 125.425 83.475) (width 0.25) (layer B.Cu) (net 80)) + (via (at 125.45 83.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 80)) + (segment (start 125.45 82.865188) (end 125.45 83.5) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 124.309812 81.725) (end 125.45 82.865188) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 122.9 81.725) (end 124.309812 81.725) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.210511 100.69384) (end 116.210511 99.326301) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.975317 101.458646) (end 116.210511 100.69384) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 123.824999 86.588189) (end 125.45 84.963188) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.210511 99.326301) (end 121.214999 94.321813) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 121.214999 90.900003) (end 123.824999 88.290003) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 125.45 84.963188) (end 125.45 83.5) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 121.214999 94.321813) (end 121.214999 90.900003) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 123.824999 88.290003) (end 123.824999 86.588189) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.975317 101.608317) (end 116.975317 101.458646) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 118.1 102.475) (end 117.842 102.475) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 117.842 102.475) (end 116.975317 101.608317) (width 0.25) (layer F.Cu) (net 80)) + (via (at 143.6 99.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 81)) + (segment (start 137.1 79.125) (end 136.325 79.125) (width 0.25) (layer B.Cu) (net 81)) + (via (at 135.35 80.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 81)) + (segment (start 136.325 79.125) (end 135.35 80.1) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 141.9 99.975) (end 142.976 99.975) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 143.6 99.351) (end 143.6 99.05) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 142.976 99.975) (end 143.6 99.351) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 142.9925 98.225) (end 143.6 98.8325) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 141.9 98.225) (end 142.9925 98.225) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 141.95 98.175) (end 141.9 98.225) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 141.95 96.55) (end 141.95 98.175) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 140.214999 94.814999) (end 141.95 96.55) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 136.125 80.875) (end 137.1 80.875) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 140.214999 89.863998) (end 140.214999 94.814999) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 143.6 98.8325) (end 143.6 99.05) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 135.35 80.1) (end 136.125 80.875) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 137.1 80.875) (end 137.1 86.748999) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 137.1 86.748999) (end 140.214999 89.863998) (width 0.25) (layer F.Cu) (net 81)) + (via (at 154.75 96.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 156.2 97.565) (end 155.775 97.565) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 155.775 97.565) (end 154.75 96.54) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 158.75 86.688998) (end 158.75 90.04) (width 0.25) (layer B.Cu) (net 82)) + (via (at 158.75 90.04) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 161 78.565) (end 161 84.438998) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 161 84.438998) (end 158.75 86.688998) (width 0.25) (layer B.Cu) (net 82)) + (via (at 155.4 92.814979) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 158.75 90.04) (end 155.975021 92.814979) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 156.2 93.614979) (end 155.4 92.814979) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 155.975021 92.814979) (end 155.4 92.814979) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 156.2 95.815) (end 156.2 93.614979) (width 0.25) (layer B.Cu) (net 82)) + (via (at 162.169493 77.468245) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 161.986745 77.468245) (end 162.169493 77.468245) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 161 76.815) (end 161.3335 76.815) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 161.3335 76.815) (end 161.986745 77.468245) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 155.702 96.0755) (end 155.9395 96.0755) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 154.75 96.54) (end 155.2375 96.54) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 155.9395 96.0755) (end 156.2 95.815) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 155.2375 96.54) (end 155.702 96.0755) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 161 78.565) (end 161.3253 78.565) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 162.169493 77.720807) (end 162.169493 77.468245) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 161.3253 78.565) (end 162.169493 77.720807) (width 0.25) (layer B.Cu) (net 82)) + (via (at 181.25 98.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 83)) + (via (at 175.25 83.425) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 83)) + (segment (start 175.224999 83.450001) (end 175.25 83.425) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 180 96.5) (end 178.314999 94.814999) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 178.314999 89.964999) (end 175.224999 86.874999) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 180 98.325) (end 180 96.5) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 178.314999 94.814999) (end 178.314999 89.964999) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 175.224999 86.874999) (end 175.224999 83.450001) (width 0.25) (layer F.Cu) (net 83)) + (via (at 173.5 80.349998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 83)) + (segment (start 175.2 80.975) (end 174.125002 80.975) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 174.125002 80.975) (end 173.5 80.349998) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 175.25 81.025) (end 175.2 80.975) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 175.25 83.425) (end 175.25 81.025) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 180 100.075) (end 180.214 100.075) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 181.25 99.039) (end 181.25 98.9) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 180.214 100.075) (end 181.25 99.039) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 180.0365 98.3615) (end 180 98.325) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 181.0385 98.3615) (end 180.0365 98.3615) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 181.25 98.9) (end 181.25 98.573) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 181.25 98.573) (end 181.0385 98.3615) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 173.5 79.738) (end 173.5 80.349998) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 175.2 79.225) (end 174.013 79.225) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 174.013 79.225) (end 173.5 79.738) (width 0.25) (layer B.Cu) (net 83)) + (via (at 193.034627 103.965373) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 193.875 103.125) (end 193.034627 103.965373) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 194.3 103.125) (end 193.875 103.125) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.4 85.875) (end 200.6 84.675) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.1 84.125) (end 200.075 84.125) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 200.075 84.125) (end 200.6 84.65) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 200.6 84.675) (end 200.6 84.65) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.1 85.875) (end 199.4 85.875) (width 0.25) (layer B.Cu) (net 84)) + (via (at 200.6 84.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 194.3 103.125) (end 194.3 100.149998) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 194.3 100.149998) (end 196.4 98.049998) (width 0.25) (layer B.Cu) (net 84)) + (via (at 196.4 98.049998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 193.034627 104.579127) (end 193.034627 103.965373) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 194.3 104.875) (end 194.275 104.85) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 193.3055 104.85) (end 193.034627 104.579127) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 194.275 104.85) (end 193.3055 104.85) (width 0.25) (layer F.Cu) (net 84)) + (via (at 199.771 87.349989) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 199.1 85.875) (end 199.1 86.678989) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.771 90.944002) (end 199.771 87.349989) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 199.1 86.678989) (end 199.771 87.349989) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 196.4 98.049998) (end 196.399999 94.315003) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 196.399999 94.315003) (end 199.771 90.944002) (width 0.25) (layer F.Cu) (net 84)) + (via (at 212 85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 85)) + (segment (start 213.3 85.875) (end 212.875 85.875) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 212.875 85.875) (end 212 85) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 219.2 104.875) (end 219.425 104.65) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 218.15 103.125) (end 219.425 103.125) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 218.15 104.875) (end 219.2 104.875) (width 0.25) (layer B.Cu) (net 85)) + (via (at 219.425 103.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 85)) + (segment (start 219.425 104.65) (end 219.425 103.125) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 219.525 103.125) (end 218.15 103.125) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 213.3 91.615002) (end 216.414999 94.730001) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 219.85 102.8) (end 219.525 103.125) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 213.3 85.875) (end 213.3 91.615002) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 216.414999 94.730001) (end 216.414999 97.014999) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 219.85 100.45) (end 219.85 102.8) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 216.414999 97.014999) (end 219.85 100.45) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 213.2875 84.1375) (end 213.3 84.125) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 212.9155 84.1375) (end 213.2875 84.1375) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 212 85) (end 212.053 85) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 212.053 85) (end 212.9155 84.1375) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 123.475 102.475) (end 124.45 101.5) (width 0.25) (layer B.Cu) (net 86)) + (segment (start 122.9 102.475) (end 123.475 102.475) (width 0.25) (layer B.Cu) (net 86)) + (via (at 124.45 101.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 86)) + (segment (start 122.9 100.725) (end 123.966 100.725) (width 0.25) (layer F.Cu) (net 86)) + (segment (start 124.45 101.209) (end 124.45 101.5) (width 0.25) (layer F.Cu) (net 86)) + (segment (start 123.966 100.725) (end 124.45 101.209) (width 0.25) (layer F.Cu) (net 86)) + (via (at 135.70001 98.757169) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (via (at 125.2076 117.128) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (via (at 125.2584 118.415) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (segment (start 129.0044 105.1456) (end 129.0044 113.3312) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 134.693093 103.368407) (end 130.781593 103.368407) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 130.781593 103.368407) (end 129.0044 105.1456) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 135.70001 99.63201) (end 136.043 99.975) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 135.70001 98.757169) (end 135.70001 99.63201) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 136.043 99.975) (end 137.1 99.975) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 137.033 101.0285) (end 134.693093 103.368407) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 137.1 99.975) (end 137.033 100.042) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 137.033 100.042) (end 137.033 101.0285) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 135.70001 98.48799) (end 135.70001 98.757169) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 137.1 98.225) (end 135.963 98.225) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 135.963 98.225) (end 135.70001 98.48799) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 129.0044 113.3312) (end 125.2076 117.128) (width 0.25) (layer F.Cu) (net 87)) + (via (at 120 125.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (segment (start 125.2076 118.3642) (end 125.2584 118.415) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 125.2076 117.128) (end 125.2076 118.3642) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 120 125.9) (end 116.584998 125.9) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 114.095313 128.389685) (end 110.610315 128.389685) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 116.584998 125.9) (end 114.095313 128.389685) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 110.610315 128.389685) (end 105.079507 133.920493) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 105.079507 133.933679) (end 105.079507 133.920493) (width 0.25) (layer B.Cu) (net 87)) + (via (at 105.132534 133.97352) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (segment (start 105.079507 133.933679) (end 105.092693 133.933679) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 105.092693 133.933679) (end 105.132534 133.97352) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 105.113471 133.97352) (end 103.430912 132.290961) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 105.132534 133.97352) (end 105.113471 133.97352) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 104.013186 135) (end 105.079507 133.933679) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 103.2 135) (end 104.013186 135) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 101.915367 133.165961) (end 101.915367 133.715367) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 101.915367 133.715367) (end 103.2 135) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 125.2584 118.415) (end 125.2584 124.639588) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 120.199999 125.700001) (end 120 125.9) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 124.197987 125.700001) (end 120.199999 125.700001) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 125.2584 124.639588) (end 124.197987 125.700001) (width 0.25) (layer F.Cu) (net 87)) + (via (at 161.45 94.69) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) + (segment (start 161.45 95.365) (end 161 95.815) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 161.45 94.69) (end 161.45 95.365) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 163.3 95.976812) (end 162.013188 94.69) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 163.3 96.99) (end 163.3 95.976812) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 162.013188 94.69) (end 161.45 94.69) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 161 97.565) (end 162.725 97.565) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 162.725 97.565) (end 163.3 96.99) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 129.508404 114.442789) (end 129.449194 114.44279) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 129.508404 114.366588) (end 129.508404 114.442789) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 129.508404 114.366588) (end 126 117.874992) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 126 117.874992) (end 117.125008 117.874992) (width 0.25) (layer F.Cu) (net 88)) + (via (at 112.5 124) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) + (segment (start 113.631807 122.863389) (end 113.631807 122.868193) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 113.631807 122.868193) (end 112.5 124) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 112.5 124) (end 112.5 124.3) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 112.753759 124.553759) (end 114.08474 124.553759) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 112.5 124.3) (end 112.753759 124.553759) (width 0.25) (layer F.Cu) (net 88)) + (via (at 116.1 119.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) + (segment (start 113.631807 122.863389) (end 113.223559 122.455141) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 114.877217 119.8) (end 116.1 119.8) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 113.223559 121.453658) (end 114.877217 119.8) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 113.223559 122.455141) (end 113.223559 121.453658) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 116.1 118.9) (end 116.65 118.35) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 116.1 119.8) (end 116.1 118.9) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 117.125008 117.874992) (end 116.65 118.35) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 116.65 118.35) (end 116.33227 118.66773) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 160.8 94.04) (end 161.45 94.69) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 147.9355 100.54) (end 148 100.54) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 148 100.54) (end 149.974999 98.565001) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 146.812 101.6635) (end 147.9355 100.54) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 149.974999 98.565001) (end 150.252001 98.565001) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 146.812 111.41918) (end 146.812 101.6635) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 154.777002 94.04) (end 160.8 94.04) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 150.252001 98.565001) (end 154.777002 94.04) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 135.326612 114.366588) (end 135.69061 114.00259) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 144.22859 114.00259) (end 146.812 111.41918) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 135.69061 114.00259) (end 144.22859 114.00259) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 129.508404 114.366588) (end 135.326612 114.366588) (width 0.25) (layer F.Cu) (net 88)) + (via (at 173.5 99.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (via (at 143.4702 117.4498) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (segment (start 142.0248 117.4498) (end 141.9 117.325) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 143.4702 117.4498) (end 142.0248 117.4498) (width 0.25) (layer F.Cu) (net 89)) + (via (at 165.949996 113.63141) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (segment (start 143.95801 117.93761) (end 143.4702 117.4498) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 141.9 119.075) (end 141.95451 119.12951) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 143.621178 119.12951) (end 143.95801 118.792678) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 141.95451 119.12951) (end 143.621178 119.12951) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 143.95801 118.792678) (end 143.95801 117.93761) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 173.5 98.915) (end 173.5 99.15) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 175.2 98.325) (end 174.09 98.325) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 174.09 98.325) (end 173.5 98.915) (width 0.25) (layer B.Cu) (net 89)) + (via (at 147.1222 121.4828) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (segment (start 143.4702 117.4498) (end 143.894511 117.874111) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 143.894511 118.255111) (end 147.1222 121.4828) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 143.894511 117.874111) (end 143.894511 118.255111) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 160.949249 118.914999) (end 154.586411 118.914999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 154.586411 118.914999) (end 153.486411 120.014999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 153.486411 120.014999) (end 152.529214 120.014999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 147.405042 121.4828) (end 147.1222 121.4828) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 152.529214 120.014999) (end 151.061413 121.4828) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 151.061413 121.4828) (end 147.405042 121.4828) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 165.949996 113.914252) (end 160.949249 118.914999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 165.949996 113.63141) (end 165.949996 113.914252) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 173.699999 99.349999) (end 173.5 99.15) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 173.699999 100.013187) (end 173.699999 99.349999) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 167 112.581406) (end 167 104.464998) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 165.949996 113.63141) (end 167 112.581406) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 170.813186 102.9) (end 173.699999 100.013187) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 167 104.464998) (end 168.564998 102.9) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 168.564998 102.9) (end 170.813186 102.9) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 173.761812 100.075) (end 173.699999 100.013187) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 175.2 100.075) (end 173.761812 100.075) (width 0.25) (layer F.Cu) (net 89)) + (via (at 200.75 103.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 200.125 103.125) (end 199.1 103.125) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 200.75 103.75) (end 200.125 103.125) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 199.1 106.325008) (end 198.249998 107.17501) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 188.214987 107.100011) (end 198.174999 107.100011) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 198.174999 107.100011) (end 198.249998 107.17501) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 199.1 104.875) (end 199.1 106.325008) (width 0.25) (layer B.Cu) (net 90)) + (via (at 198.249998 107.17501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 185.95001 109.364988) (end 188.214987 107.100011) (width 0.25) (layer F.Cu) (net 90)) + (via (at 154.7986 116.0782) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 154.7986 115.3162) (end 154.7986 116.0782) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.2 114.915) (end 155.1998 114.915) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 155.1998 114.915) (end 154.7986 115.3162) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.172 116.637) (end 156.2 116.665) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 155.0018 116.637) (end 156.172 116.637) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 154.7986 116.0782) (end 154.7986 116.4338) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 154.7986 116.4338) (end 155.0018 116.637) (width 0.25) (layer F.Cu) (net 90)) + (via (at 184.633532 112.308932) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 200.75 104.3675) (end 200.75 103.75) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 199.1 104.875) (end 200.2425 104.875) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 200.2425 104.875) (end 200.75 104.3675) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.2 113.620901) (end 156.714501 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.272622 113.15641) (end 163.748978 113.15641) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.748978 113.15641) (end 163.798988 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 183.836064 113.1064) (end 184.633532 112.308932) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.714501 113.1064) (end 163.222612 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.798988 113.1064) (end 183.836064 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.2 114.915) (end 156.2 113.620901) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.222612 113.1064) (end 163.272622 113.15641) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 185.95001 109.364988) (end 185.95001 110.992454) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 185.95001 110.992454) (end 185.847332 111.095132) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 184.633532 112.308932) (end 185.847332 111.095132) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 180 117.425) (end 180.5594 116.8656) (width 0.25) (layer F.Cu) (net 91)) + (via (at 181.7734 118.2626) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 91)) + (segment (start 181.7734 117.221396) (end 181.7734 118.2626) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 180.5594 116.8656) (end 181.417604 116.8656) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 181.417604 116.8656) (end 181.7734 117.221396) (width 0.25) (layer F.Cu) (net 91)) + (via (at 183.5768 118.1102) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 91)) + (segment (start 183.4244 118.2626) (end 183.5768 118.1102) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.7734 118.2626) (end 183.4244 118.2626) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.1165 119.175) (end 180 119.175) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.7734 118.2626) (end 181.7734 118.5181) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.7734 118.5181) (end 181.1165 119.175) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 183.5768 117.986002) (end 183.5768 118.1102) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 212.925 104.875) (end 206.502 111.298) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 185.103602 116.4592) (end 183.5768 117.986002) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.35 104.875) (end 212.925 104.875) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 206.502 113.3475) (end 203.3903 116.4592) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 206.502 111.298) (end 206.502 113.3475) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 203.3903 116.4592) (end 185.103602 116.4592) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.35 104.875) (end 213.07501 104.875) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.35 103.125) (end 213.17501 103.125) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 213.07501 104.875) (end 212.25001 104.05) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.17501 103.125) (end 212.25001 104.05) (width 0.25) (layer B.Cu) (net 91)) + (via (at 212.25001 104.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 91)) + (via (at 98.5092 126.9858) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 99.882673 126.9858) (end 98.5092 126.9858) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 101.030912 128.134039) (end 99.882673 126.9858) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 98.5092 126.9858) (end 98.2 127.295) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 98.2 127.693672) (end 99.515367 129.009039) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 98.2 127.295) (end 98.2 127.693672) (width 0.25) (layer F.Cu) (net 92)) + (via (at 110.3 127.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 116.858981 125.626017) (end 116.95608 125.6) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 110.3 127.1) (end 115.384998 127.1) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 115.384998 127.1) (end 116.858981 125.626017) (width 0.25) (layer F.Cu) (net 92)) + (via (at 119.8 124.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 116.95608 125.6) (end 119 125.6) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 119 125.6) (end 119.8 124.8) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 119.8 124.390243) (end 118.721184 123.311427) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 119.8 124.8) (end 119.8 124.390243) (width 0.25) (layer B.Cu) (net 92)) + (via (at 120 122.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 118.721184 123.311427) (end 118.888573 123.311427) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 118.888573 123.311427) (end 120 122.2) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 118.847194 122.2) (end 118.268251 121.621057) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 120 122.2) (end 118.847194 122.2) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 107.1 127.1) (end 110.3 127.1) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 106.580662 127.619338) (end 107.1 127.1) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 101.030912 128.134039) (end 101.545613 127.619338) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 101.545613 127.619338) (end 106.580662 127.619338) (width 0.25) (layer B.Cu) (net 92)) + (via (at 135.6216 117.9578) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 137.1 119.075) (end 136.7388 119.075) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 136.7388 119.075) (end 135.6216 117.9578) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 136.4672 117.9578) (end 137.1 117.325) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 135.6216 117.9578) (end 136.4672 117.9578) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 137.1 116.033901) (end 137.584711 115.54919) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 137.1 117.325) (end 137.1 116.033901) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 137.584711 115.54919) (end 137.64921 115.54919) (width 0.25) (layer B.Cu) (net 93)) + (via (at 141.3112 115.0114) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 137.64921 115.54919) (end 138.187 115.0114) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 138.187 115.0114) (end 141.3112 115.0114) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 161 113.1864) (end 160.8438 113.0302) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 160.8438 113.0302) (end 154.6862 113.0302) (width 0.25) (layer F.Cu) (net 93)) + (via (at 154.6862 113.0302) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 161 114.915) (end 161 113.1864) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 152.4633 113.0302) (end 152.4 113.0935) (width 0.25) (layer B.Cu) (net 93)) + (via (at 152.4 113.0935) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 141.3112 115.0114) (end 150.4821 115.0114) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 154.6862 113.0302) (end 152.4633 113.0302) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 150.4821 115.0114) (end 152.4 113.0935) (width 0.25) (layer F.Cu) (net 93)) + (via (at 162.493589 114.386621) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 163.2 116.013188) (end 163.2 115.093032) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 162.548188 116.665) (end 163.2 116.013188) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 163.2 115.093032) (end 162.493589 114.386621) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 161 116.665) (end 162.548188 116.665) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 161.96521 114.915) (end 162.493589 114.386621) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 161 114.915) (end 161.96521 114.915) (width 0.25) (layer F.Cu) (net 93)) + (via (at 181.113 120.2438) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 94)) + (segment (start 181.113 120.788) (end 181.113 120.2438) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 182.85 121.195) (end 181.52 121.195) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 181.52 121.195) (end 181.113 120.788) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 178.9051 114.7066) (end 178.827 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.2435 119.445) (end 182.85 119.445) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 181.113 120.2438) (end 181.4447 120.2438) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 181.4447 120.2438) (end 182.2435 119.445) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 175.2 115.8336) (end 175.2 117.425) (width 0.25) (layer B.Cu) (net 94)) + (via (at 173.8232 118.288) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 94)) + (segment (start 173.8232 118.288) (end 174.041 118.288) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 174.928 119.175) (end 175.2 119.175) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 174.041 118.288) (end 174.928 119.175) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 174.0081 118.288) (end 173.8232 118.288) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 175.2 117.425) (end 174.8711 117.425) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 174.8711 117.425) (end 174.0081 118.288) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 176.327 114.7066) (end 175.2 115.8336) (width 0.25) (layer F.Cu) (net 94)) + (via (at 175.2 115.8336) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 94)) + (segment (start 178.9051 114.7066) (end 176.327 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 185.4454 110.409602) (end 185.4454 100.1522) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 178.9051 114.7066) (end 181.148402 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 183.119201 112.735801) (end 185.4454 110.409602) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 181.148402 114.7066) (end 183.119201 112.735801) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.85 113.005002) (end 183.119201 112.735801) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.85 116.408198) (end 181.148402 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.85 119.445) (end 182.85 116.408198) (width 0.25) (layer F.Cu) (net 94)) + + (zone (net 34) (net_name GND) (layer F.Cu) (tstamp 6039FDAD) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508) (smoothing chamfer)) + (polygon + (pts + (xy 80.95 127.2) (xy 92.9 147.65) (xy 138 134.95) (xy 157.25 135.05) (xy 187.45 134.85) + (xy 225.9 121.5) (xy 226 42.8) (xy 171.7 34.3) (xy 87.45 36.6) (xy 87.8 115) + ) + ) + (filled_polygon + (pts + (xy 224.336807 44.116746) (xy 224.447617 44.145115) (xy 224.521481 44.178972) (xy 224.587585 44.224767) (xy 224.644771 44.281261) + (xy 224.691436 44.346768) (xy 224.726105 44.419343) (xy 224.747732 44.497657) (xy 224.758192 44.613012) (xy 224.785002 119.001646) + (xy 215.240448 122.646508) (xy 214.443004 120.569096) (xy 187.241582 131.010743) (xy 188.020945 133.041054) (xy 187.30358 133.315) + (xy 138.158838 133.315) (xy 138.096265 133.314123) (xy 138.058284 133.321126) (xy 138.019845 133.324912) (xy 137.959927 133.343088) + (xy 93.864605 146.047335) (xy 93.520432 145.984758) (xy 93.243912 145.892584) (xy 93.08499 145.756366) (xy 82.933274 128.127044) + (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583074 116.011918) + (xy 88.59798 115.990873) (xy 88.615021 115.952706) (xy 88.618829 115.945648) (xy 88.62876 115.921935) (xy 88.639207 115.898536) + (xy 88.641735 115.890952) (xy 88.657891 115.852374) (xy 88.663024 115.827087) (xy 88.84031 115.29523) (xy 88.855164 115.261034) + (xy 88.868713 115.198522) (xy 88.882908 115.13609) (xy 88.883923 115.098817) (xy 88.948633 114.539922) (xy 88.950347 114.53427) + (xy 88.956379 114.473019) (xy 88.959581 114.44536) (xy 88.959682 114.439478) (xy 88.960257 114.433634) (xy 88.960256 114.405836) + (xy 88.961309 114.344252) (xy 88.960255 114.338437) (xy 88.96016 109.1) (xy 97.761928 109.1) (xy 97.761928 111.1) + (xy 97.774188 111.224482) (xy 97.810498 111.34418) (xy 97.869463 111.454494) (xy 97.948815 111.551185) (xy 98.045506 111.630537) + (xy 98.15582 111.689502) (xy 98.275518 111.725812) (xy 98.4 111.738072) (xy 101.6 111.738072) (xy 101.724482 111.725812) + (xy 101.84418 111.689502) (xy 101.954494 111.630537) (xy 102.051185 111.551185) (xy 102.130537 111.454494) (xy 102.189502 111.34418) + (xy 102.225812 111.224482) (xy 102.238072 111.1) (xy 102.238072 109.1) (xy 102.225812 108.975518) (xy 102.189502 108.85582) + (xy 102.130537 108.745506) (xy 102.051185 108.648815) (xy 101.954494 108.569463) (xy 101.84418 108.510498) (xy 101.724482 108.474188) + (xy 101.6 108.461928) (xy 98.4 108.461928) (xy 98.275518 108.474188) (xy 98.15582 108.510498) (xy 98.045506 108.569463) + (xy 97.948815 108.648815) (xy 97.869463 108.745506) (xy 97.810498 108.85582) (xy 97.774188 108.975518) (xy 97.761928 109.1) + (xy 88.96016 109.1) (xy 88.960118 106.838967) (xy 90.865 106.838967) (xy 90.865 107.161033) (xy 90.927832 107.476912) + (xy 91.051082 107.774463) (xy 91.230013 108.042252) (xy 91.457748 108.269987) (xy 91.725537 108.448918) (xy 92.023088 108.572168) + (xy 92.338967 108.635) (xy 92.661033 108.635) (xy 92.976912 108.572168) (xy 93.274463 108.448918) (xy 93.542252 108.269987) + (xy 93.769987 108.042252) (xy 93.948918 107.774463) (xy 94.072168 107.476912) (xy 94.135 107.161033) (xy 94.135 106.838967) + (xy 105.365 106.838967) (xy 105.365 107.161033) (xy 105.427832 107.476912) (xy 105.551082 107.774463) (xy 105.730013 108.042252) + (xy 105.957748 108.269987) (xy 106.225537 108.448918) (xy 106.523088 108.572168) (xy 106.838967 108.635) (xy 107.161033 108.635) + (xy 107.476912 108.572168) (xy 107.774463 108.448918) (xy 108.042252 108.269987) (xy 108.269987 108.042252) (xy 108.448918 107.774463) + (xy 108.572168 107.476912) (xy 108.635 107.161033) (xy 108.635 106.838967) (xy 108.572168 106.523088) (xy 108.448918 106.225537) + (xy 108.269987 105.957748) (xy 108.042252 105.730013) (xy 107.774463 105.551082) (xy 107.476912 105.427832) (xy 107.161033 105.365) + (xy 106.838967 105.365) (xy 106.523088 105.427832) (xy 106.225537 105.551082) (xy 105.957748 105.730013) (xy 105.730013 105.957748) + (xy 105.551082 106.225537) (xy 105.427832 106.523088) (xy 105.365 106.838967) (xy 94.135 106.838967) (xy 94.072168 106.523088) + (xy 93.948918 106.225537) (xy 93.769987 105.957748) (xy 93.542252 105.730013) (xy 93.445065 105.665075) (xy 93.455808 105.635413) + (xy 92.5 104.679605) (xy 91.544192 105.635413) (xy 91.554935 105.665075) (xy 91.457748 105.730013) (xy 91.230013 105.957748) + (xy 91.051082 106.225537) (xy 90.927832 106.523088) (xy 90.865 106.838967) (xy 88.960118 106.838967) (xy 88.960076 104.562595) + (xy 90.858282 104.562595) (xy 90.902039 104.881675) (xy 91.007205 105.186088) (xy 91.100186 105.360044) (xy 91.364587 105.455808) + (xy 92.320395 104.5) (xy 92.679605 104.5) (xy 93.635413 105.455808) (xy 93.899814 105.360044) (xy 94.040704 105.070429) + (xy 94.122384 104.758892) (xy 94.141718 104.437405) (xy 94.097961 104.118325) (xy 93.992795 103.813912) (xy 93.899814 103.639956) + (xy 93.635413 103.544192) (xy 92.679605 104.5) (xy 92.320395 104.5) (xy 91.364587 103.544192) (xy 91.100186 103.639956) + (xy 90.959296 103.929571) (xy 90.877616 104.241108) (xy 90.858282 104.562595) (xy 88.960076 104.562595) (xy 88.960026 101.838967) + (xy 90.865 101.838967) (xy 90.865 102.161033) (xy 90.927832 102.476912) (xy 91.051082 102.774463) (xy 91.230013 103.042252) + (xy 91.457748 103.269987) (xy 91.554935 103.334925) (xy 91.544192 103.364587) (xy 92.5 104.320395) (xy 93.455808 103.364587) + (xy 93.445065 103.334925) (xy 93.542252 103.269987) (xy 93.769987 103.042252) (xy 93.948918 102.774463) (xy 94.072168 102.476912) + (xy 94.135 102.161033) (xy 94.135 101.838967) (xy 94.072168 101.523088) (xy 93.948918 101.225537) (xy 93.769987 100.957748) + (xy 93.542252 100.730013) (xy 93.274463 100.551082) (xy 92.976912 100.427832) (xy 92.661033 100.365) (xy 92.338967 100.365) + (xy 92.023088 100.427832) (xy 91.725537 100.551082) (xy 91.457748 100.730013) (xy 91.230013 100.957748) (xy 91.051082 101.225537) + (xy 90.927832 101.523088) (xy 90.865 101.838967) (xy 88.960026 101.838967) (xy 88.959953 97.9) (xy 97.761928 97.9) + (xy 97.761928 99.9) (xy 97.774188 100.024482) (xy 97.810498 100.14418) (xy 97.869463 100.254494) (xy 97.948815 100.351185) + (xy 98.045506 100.430537) (xy 98.15582 100.489502) (xy 98.275518 100.525812) (xy 98.4 100.538072) (xy 101.6 100.538072) + (xy 101.724482 100.525812) (xy 101.84418 100.489502) (xy 101.954494 100.430537) (xy 102.051185 100.351185) (xy 102.130537 100.254494) + (xy 102.189502 100.14418) (xy 102.225812 100.024482) (xy 102.238072 99.9) (xy 102.238072 97.9) (xy 102.225812 97.775518) + (xy 102.189502 97.65582) (xy 102.130537 97.545506) (xy 102.051185 97.448815) (xy 101.954494 97.369463) (xy 101.84418 97.310498) + (xy 101.724482 97.274188) (xy 101.6 97.261928) (xy 98.4 97.261928) (xy 98.275518 97.274188) (xy 98.15582 97.310498) + (xy 98.045506 97.369463) (xy 97.948815 97.448815) (xy 97.869463 97.545506) (xy 97.810498 97.65582) (xy 97.774188 97.775518) + (xy 97.761928 97.9) (xy 88.959953 97.9) (xy 88.959885 94.236545) (xy 88.966261 94.268601) (xy 89.164893 94.748141) + (xy 89.453262 95.179715) (xy 89.820285 95.546738) (xy 90.251859 95.835107) (xy 90.731399 96.033739) (xy 91.240475 96.135) + (xy 91.759525 96.135) (xy 92.268601 96.033739) (xy 92.748141 95.835107) (xy 93.179715 95.546738) (xy 93.546738 95.179715) + (xy 93.835107 94.748141) (xy 94.033739 94.268601) (xy 94.135 93.759525) (xy 94.135 93.240475) (xy 94.033739 92.731399) + (xy 93.835107 92.251859) (xy 93.546738 91.820285) (xy 93.179715 91.453262) (xy 92.748141 91.164893) (xy 92.268601 90.966261) + (xy 92.095535 90.931836) (xy 92.271034 90.878599) (xy 92.529014 90.740706) (xy 92.755134 90.555134) (xy 92.800624 90.499705) + (xy 92.969381 90.664176) (xy 93.214382 90.823361) (xy 93.485731 90.93169) (xy 93.773 90.985) (xy 94.173 90.985) + (xy 94.173 89.627) (xy 94.427 89.627) (xy 94.427 90.985) (xy 94.827 90.985) (xy 95.114269 90.93169) + (xy 95.385618 90.823361) (xy 95.630619 90.664176) (xy 95.839857 90.460252) (xy 96.005291 90.219426) (xy 96.120563 89.950953) + (xy 96.141476 89.85689) (xy 96.020155 89.627) (xy 94.427 89.627) (xy 94.173 89.627) (xy 94.153 89.627) + (xy 94.153 89.373) (xy 94.173 89.373) (xy 94.173 88.015) (xy 94.427 88.015) (xy 94.427 89.373) + (xy 96.020155 89.373) (xy 96.141476 89.14311) (xy 96.120563 89.049047) (xy 96.005291 88.780574) (xy 95.839857 88.539748) + (xy 95.630619 88.335824) (xy 95.385618 88.176639) (xy 95.114269 88.06831) (xy 94.827 88.015) (xy 94.427 88.015) + (xy 94.173 88.015) (xy 93.773 88.015) (xy 93.485731 88.06831) (xy 93.214382 88.176639) (xy 92.969381 88.335824) + (xy 92.800624 88.500295) (xy 92.755134 88.444866) (xy 92.529014 88.259294) (xy 92.271034 88.121401) (xy 92.06 88.057384) + (xy 92.06 84.992616) (xy 92.271034 84.928599) (xy 92.529014 84.790706) (xy 92.755134 84.605134) (xy 92.800624 84.549705) + (xy 92.969381 84.714176) (xy 93.214382 84.873361) (xy 93.485731 84.98169) (xy 93.773 85.035) (xy 94.173 85.035) + (xy 94.173 83.677) (xy 94.427 83.677) (xy 94.427 85.035) (xy 94.827 85.035) (xy 95.114269 84.98169) + (xy 95.385618 84.873361) (xy 95.630619 84.714176) (xy 95.839857 84.510252) (xy 96.005291 84.269426) (xy 96.120563 84.000953) + (xy 96.141476 83.90689) (xy 96.020155 83.677) (xy 94.427 83.677) (xy 94.173 83.677) (xy 94.153 83.677) + (xy 94.153 83.423) (xy 94.173 83.423) (xy 94.173 83.403) (xy 94.427 83.403) (xy 94.427 83.423) + (xy 96.020155 83.423) (xy 96.141476 83.19311) (xy 96.128554 83.13499) (xy 96.474071 83.13499) (xy 96.436487 83.258889) + (xy 96.407815 83.55) (xy 96.436487 83.841111) (xy 96.521401 84.121034) (xy 96.659294 84.379014) (xy 96.701935 84.430972) + (xy 96.621637 84.415) (xy 96.378363 84.415) (xy 96.139764 84.46246) (xy 95.915008 84.555557) (xy 95.712733 84.690713) + (xy 95.540713 84.862733) (xy 95.405557 85.065008) (xy 95.31246 85.289764) (xy 95.265 85.528363) (xy 95.265 85.771637) + (xy 95.31246 86.010236) (xy 95.405557 86.234992) (xy 95.540713 86.437267) (xy 95.628446 86.525) (xy 95.540713 86.612733) + (xy 95.405557 86.815008) (xy 95.31246 87.039764) (xy 95.265 87.278363) (xy 95.265 87.521637) (xy 95.31246 87.760236) + (xy 95.405557 87.984992) (xy 95.540713 88.187267) (xy 95.712733 88.359287) (xy 95.915008 88.494443) (xy 96.139764 88.58754) + (xy 96.378363 88.635) (xy 96.621637 88.635) (xy 96.701935 88.619028) (xy 96.659294 88.670986) (xy 96.521401 88.928966) + (xy 96.436487 89.208889) (xy 96.407815 89.5) (xy 96.436487 89.791111) (xy 96.521401 90.071034) (xy 96.659294 90.329014) + (xy 96.844866 90.555134) (xy 97.070986 90.740706) (xy 97.328966 90.878599) (xy 97.608889 90.963513) (xy 97.82705 90.985) + (xy 98.77295 90.985) (xy 98.991111 90.963513) (xy 99.271034 90.878599) (xy 99.529014 90.740706) (xy 99.755134 90.555134) + (xy 99.940706 90.329014) (xy 100.078599 90.071034) (xy 100.163513 89.791111) (xy 100.192185 89.5) (xy 100.166085 89.235) + (xy 100.27295 89.235) (xy 100.491111 89.213513) (xy 100.771034 89.128599) (xy 101.029014 88.990706) (xy 101.255134 88.805134) + (xy 101.440706 88.579014) (xy 101.578599 88.321034) (xy 101.663513 88.041111) (xy 101.679873 87.875) (xy 101.911928 87.875) + (xy 101.924188 87.999482) (xy 101.960498 88.11918) (xy 102.019463 88.229494) (xy 102.098815 88.326185) (xy 102.195506 88.405537) + (xy 102.30582 88.464502) (xy 102.425518 88.500812) (xy 102.55 88.513072) (xy 103.26425 88.51) (xy 103.423 88.35125) + (xy 103.423 87.502) (xy 103.677 87.502) (xy 103.677 88.35125) (xy 103.83575 88.51) (xy 104.55 88.513072) + (xy 104.674482 88.500812) (xy 104.79418 88.464502) (xy 104.904494 88.405537) (xy 105.001185 88.326185) (xy 105.080537 88.229494) + (xy 105.139502 88.11918) (xy 105.175812 87.999482) (xy 105.188072 87.875) (xy 105.185 87.66075) (xy 105.02625 87.502) + (xy 103.677 87.502) (xy 103.423 87.502) (xy 102.07375 87.502) (xy 101.915 87.66075) (xy 101.911928 87.875) + (xy 101.679873 87.875) (xy 101.692185 87.75) (xy 101.663513 87.458889) (xy 101.578599 87.178966) (xy 101.440706 86.920986) + (xy 101.255134 86.694866) (xy 101.048152 86.525) (xy 101.255134 86.355134) (xy 101.440706 86.129014) (xy 101.578599 85.871034) + (xy 101.663513 85.591111) (xy 101.692185 85.3) (xy 101.663513 85.008889) (xy 101.640797 84.934004) (xy 103.211003 83.363799) + (xy 103.240001 83.340001) (xy 103.277705 83.294059) (xy 103.334974 83.224277) (xy 103.405546 83.092247) (xy 103.415571 83.059197) + (xy 103.449003 82.948986) (xy 103.46 82.837333) (xy 103.46 82.837323) (xy 103.463676 82.8) (xy 103.46 82.762677) + (xy 103.46 81.395971) (xy 103.550057 81.335797) (xy 103.735797 81.150057) (xy 103.881732 80.931649) (xy 103.982254 80.688968) + (xy 104.0335 80.431338) (xy 104.0335 80.168662) (xy 103.982254 79.911032) (xy 103.881732 79.668351) (xy 103.785798 79.524775) + (xy 103.843468 79.595046) (xy 103.843471 79.595049) (xy 103.871184 79.628817) (xy 103.904951 79.656529) (xy 105.604953 81.356532) + (xy 105.604959 81.356537) (xy 105.74 81.491578) (xy 105.739999 82.64) (xy 105.024822 82.64) (xy 104.9875 82.636324) + (xy 104.950177 82.64) (xy 104.950167 82.64) (xy 104.838514 82.650997) (xy 104.709936 82.69) (xy 104.695253 82.694454) + (xy 104.563223 82.765026) (xy 104.492144 82.82336) (xy 104.447499 82.859999) (xy 104.423701 82.888997) (xy 103.038998 84.273701) + (xy 103.01 84.297499) (xy 102.986202 84.326497) (xy 102.986201 84.326498) (xy 102.915026 84.413224) (xy 102.87563 84.486928) + (xy 102.55 84.486928) (xy 102.425518 84.499188) (xy 102.30582 84.535498) (xy 102.195506 84.594463) (xy 102.098815 84.673815) + (xy 102.019463 84.770506) (xy 101.960498 84.88082) (xy 101.924188 85.000518) (xy 101.911928 85.125) (xy 101.911928 86.125) + (xy 101.924188 86.249482) (xy 101.960498 86.36918) (xy 102.019463 86.479494) (xy 102.036292 86.5) (xy 102.019463 86.520506) + (xy 101.960498 86.63082) (xy 101.924188 86.750518) (xy 101.911928 86.875) (xy 101.915 87.08925) (xy 102.07375 87.248) + (xy 103.423 87.248) (xy 103.423 87.228) (xy 103.677 87.228) (xy 103.677 87.248) (xy 104.316165 87.248) + (xy 104.460683 87.307861) (xy 104.622003 87.33995) (xy 104.786483 87.33995) (xy 104.947803 87.307861) (xy 105.099764 87.244917) + (xy 105.236524 87.153537) (xy 105.35283 87.037231) (xy 105.44421 86.900471) (xy 105.507154 86.74851) (xy 105.515001 86.709063) + (xy 105.515001 87.243477) (xy 105.527806 87.37349) (xy 105.578412 87.540313) (xy 105.66059 87.694059) (xy 105.771184 87.828817) + (xy 105.905942 87.939411) (xy 106.059688 88.021589) (xy 106.226511 88.072195) (xy 106.349933 88.084351) (xy 106.360498 88.11918) + (xy 106.419463 88.229494) (xy 106.498815 88.326185) (xy 106.595506 88.405537) (xy 106.70582 88.464502) (xy 106.825518 88.500812) + (xy 106.95 88.513072) (xy 108.95 88.513072) (xy 108.99 88.509132) (xy 108.990001 91.763548) (xy 108.679715 91.453262) + (xy 108.248141 91.164893) (xy 107.768601 90.966261) (xy 107.259525 90.865) (xy 106.740475 90.865) (xy 106.231399 90.966261) + (xy 105.751859 91.164893) (xy 105.320285 91.453262) (xy 104.953262 91.820285) (xy 104.664893 92.251859) (xy 104.466261 92.731399) + (xy 104.365 93.240475) (xy 104.365 93.759525) (xy 104.466261 94.268601) (xy 104.664893 94.748141) (xy 104.953262 95.179715) + (xy 105.320285 95.546738) (xy 105.751859 95.835107) (xy 105.877579 95.887182) (xy 105.875 95.886928) (xy 104.575 95.886928) + (xy 104.450518 95.899188) (xy 104.33082 95.935498) (xy 104.220506 95.994463) (xy 104.123815 96.073815) (xy 104.044463 96.170506) + (xy 103.985498 96.28082) (xy 103.949188 96.400518) (xy 103.936928 96.525) (xy 103.936928 97.475) (xy 103.949188 97.599482) + (xy 103.985498 97.71918) (xy 104.044463 97.829494) (xy 104.123815 97.926185) (xy 104.220506 98.005537) (xy 104.33082 98.064502) + (xy 104.450518 98.100812) (xy 104.575 98.113072) (xy 105.490001 98.113072) (xy 105.490001 98.212668) (xy 105.486324 98.25) + (xy 105.490001 98.287333) (xy 105.500998 98.398986) (xy 105.503801 98.408225) (xy 105.544454 98.542246) (xy 105.615026 98.674276) + (xy 105.683303 98.757471) (xy 105.71 98.790001) (xy 105.738998 98.813799) (xy 107.322271 100.397072) (xy 107.161033 100.365) + (xy 106.838967 100.365) (xy 106.523088 100.427832) (xy 106.225537 100.551082) (xy 105.957748 100.730013) (xy 105.730013 100.957748) + (xy 105.551082 101.225537) (xy 105.427832 101.523088) (xy 105.365 101.838967) (xy 105.365 102.161033) (xy 105.427832 102.476912) + (xy 105.551082 102.774463) (xy 105.730013 103.042252) (xy 105.957748 103.269987) (xy 106.225537 103.448918) (xy 106.523088 103.572168) + (xy 106.838967 103.635) (xy 107.161033 103.635) (xy 107.476912 103.572168) (xy 107.774463 103.448918) (xy 108.042252 103.269987) + (xy 108.269987 103.042252) (xy 108.448918 102.774463) (xy 108.572168 102.476912) (xy 108.635 102.161033) (xy 108.635 101.838967) + (xy 108.602928 101.67773) (xy 109.24 102.314802) (xy 109.240001 118.959797) (xy 109.220376 118.979422) (xy 109.116779 119.022333) + (xy 108.980019 119.113713) (xy 108.863713 119.230019) (xy 108.772333 119.366779) (xy 108.729421 119.470377) (xy 108.688071 119.511728) + (xy 107.9998 119.511728) (xy 107.875318 119.523988) (xy 107.75562 119.560298) (xy 107.645306 119.619263) (xy 107.548615 119.698615) + (xy 107.469263 119.795306) (xy 107.432117 119.8648) (xy 106.412522 119.8648) (xy 106.375199 119.861124) (xy 106.337876 119.8648) + (xy 106.337867 119.8648) (xy 106.226214 119.875797) (xy 106.082953 119.919254) (xy 105.950924 119.989826) (xy 105.934885 120.002989) + (xy 105.864196 120.061001) (xy 105.864192 120.061005) (xy 105.835199 120.084799) (xy 105.811405 120.113792) (xy 105.740027 120.18517) + (xy 105.870288 119.870692) (xy 105.985 119.293997) (xy 105.985 118.706003) (xy 105.870288 118.129308) (xy 105.645273 117.586072) + (xy 105.318601 117.097174) (xy 104.902826 116.681399) (xy 104.413928 116.354727) (xy 103.870692 116.129712) (xy 103.293997 116.015) + (xy 102.706003 116.015) (xy 102.129308 116.129712) (xy 101.586072 116.354727) (xy 101.097174 116.681399) (xy 100.681399 117.097174) + (xy 100.354727 117.586072) (xy 100.129712 118.129308) (xy 100.015 118.706003) (xy 100.015 119.293997) (xy 100.129712 119.870692) + (xy 100.354727 120.413928) (xy 100.681399 120.902826) (xy 101.097174 121.318601) (xy 101.586072 121.645273) (xy 102.116059 121.8648) + (xy 100.994489 121.8648) (xy 100.948986 121.850997) (xy 100.837333 121.84) (xy 100.837322 121.84) (xy 100.8 121.836324) + (xy 100.762678 121.84) (xy 100.547157 121.84) (xy 100.44356 121.797089) (xy 100.28224 121.765) (xy 100.11776 121.765) + (xy 99.95644 121.797089) (xy 99.804479 121.860033) (xy 99.769769 121.883226) (xy 99.732753 121.894454) (xy 99.600724 121.965026) + (xy 99.484999 122.059999) (xy 99.461201 122.088997) (xy 99.06327 122.486928) (xy 98.375 122.486928) (xy 98.250518 122.499188) + (xy 98.13082 122.535498) (xy 98.020506 122.594463) (xy 97.923815 122.673815) (xy 97.844463 122.770506) (xy 97.785498 122.88082) + (xy 97.749188 123.000518) (xy 97.736928 123.125) (xy 97.736928 124.075) (xy 97.749188 124.199482) (xy 97.785498 124.31918) + (xy 97.844463 124.429494) (xy 97.923815 124.526185) (xy 98.020506 124.605537) (xy 98.13082 124.664502) (xy 98.230467 124.69473) + (xy 96.599199 126.326) (xy 96.123323 126.326) (xy 96.086 126.322324) (xy 96.048677 126.326) (xy 96.048667 126.326) + (xy 95.937014 126.336997) (xy 95.816678 126.3735) (xy 95.793753 126.380454) (xy 95.661723 126.451026) (xy 95.625918 126.480411) + (xy 95.545999 126.545999) (xy 95.5222 126.574998) (xy 95.131609 126.96559) (xy 91.915211 126.96559) (xy 91.906978 126.964779) + (xy 91.819266 126.812857) (xy 91.746407 126.711183) (xy 91.655113 126.625676) (xy 91.548891 126.559624) (xy 91.431824 126.515563) + (xy 91.308411 126.495187) (xy 91.183394 126.49928) (xy 91.061577 126.527683) (xy 90.947643 126.579307) (xy 89.215593 127.579307) + (xy 89.113919 127.652165) (xy 89.028412 127.743459) (xy 88.96236 127.849681) (xy 88.918299 127.966748) (xy 88.897923 128.090161) + (xy 88.902016 128.215178) (xy 88.930419 128.336995) (xy 88.982042 128.450929) (xy 90.132042 130.442787) (xy 90.204901 130.544461) + (xy 90.296195 130.629968) (xy 90.402417 130.69602) (xy 90.519484 130.740081) (xy 90.553188 130.745646) (xy 90.552342 130.747688) + (xy 90.470295 131.160165) (xy 90.470295 131.580723) (xy 90.488699 131.673246) (xy 90.417835 131.687342) (xy 90.029289 131.848283) + (xy 89.679608 132.081932) (xy 89.382228 132.379312) (xy 89.148579 132.728993) (xy 89.047535 132.972934) (xy 89.012967 132.889479) + (xy 88.921587 132.752719) (xy 88.805281 132.636413) (xy 88.668521 132.545033) (xy 88.51656 132.482089) (xy 88.35524 132.45) + (xy 88.19076 132.45) (xy 88.02944 132.482089) (xy 87.877479 132.545033) (xy 87.740719 132.636413) (xy 87.624413 132.752719) + (xy 87.533033 132.889479) (xy 87.470089 133.04144) (xy 87.438 133.20276) (xy 87.438 133.36724) (xy 87.470089 133.52856) + (xy 87.513001 133.632158) (xy 87.513 134.235677) (xy 87.509324 134.273) (xy 87.513 134.310322) (xy 87.513 134.310332) + (xy 87.523997 134.421985) (xy 87.563309 134.551582) (xy 87.567454 134.565246) (xy 87.638026 134.697276) (xy 87.658746 134.722523) + (xy 87.732999 134.813001) (xy 87.762003 134.836804) (xy 90.240001 137.314804) (xy 90.24 138.222793) (xy 90.236324 138.260116) + (xy 90.24 138.297438) (xy 90.24 138.297448) (xy 90.250997 138.409101) (xy 90.293795 138.550188) (xy 90.294454 138.552362) + (xy 90.365026 138.684392) (xy 90.377908 138.700088) (xy 90.459999 138.800117) (xy 90.489003 138.82392) (xy 93.07243 141.407348) + (xy 93.096228 141.436346) (xy 93.211953 141.531319) (xy 93.343982 141.601891) (xy 93.487243 141.645348) (xy 93.598896 141.656345) + (xy 93.598906 141.656345) (xy 93.636229 141.660021) (xy 93.67327 141.656373) (xy 94.282338 142.71131) (xy 94.355197 142.812984) + (xy 94.446491 142.898491) (xy 94.552713 142.964543) (xy 94.66978 143.008604) (xy 94.793193 143.02898) (xy 94.91821 143.024887) + (xy 95.040027 142.996484) (xy 95.153961 142.94486) (xy 96.886011 141.94486) (xy 96.987685 141.872002) (xy 97.073192 141.780708) + (xy 97.139244 141.674486) (xy 97.183305 141.557419) (xy 97.203681 141.434006) (xy 97.199588 141.308989) (xy 97.171185 141.187172) + (xy 97.119562 141.073238) (xy 96.560294 140.104557) (xy 96.625574 140.104557) (xy 97.038051 140.02251) (xy 97.426597 139.861569) + (xy 97.776278 139.62792) (xy 98.020157 139.384041) (xy 97.947033 139.493479) (xy 97.884089 139.64544) (xy 97.852 139.80676) + (xy 97.852 139.97124) (xy 97.884089 140.13256) (xy 97.947033 140.284521) (xy 98.038413 140.421281) (xy 98.154719 140.537587) + (xy 98.291479 140.628967) (xy 98.44344 140.691911) (xy 98.60476 140.724) (xy 98.76924 140.724) (xy 98.93056 140.691911) + (xy 99.029533 140.650915) (xy 99.047411 140.652676) (xy 99.084733 140.649) (xy 99.084744 140.649) (xy 99.196397 140.638003) + (xy 99.339658 140.594546) (xy 99.471687 140.523974) (xy 99.587412 140.429001) (xy 99.611215 140.399997) (xy 101.511003 138.50021) + (xy 101.540001 138.476412) (xy 101.634974 138.360687) (xy 101.705546 138.228658) (xy 101.749003 138.085397) (xy 101.76 137.973744) + (xy 101.76 137.973734) (xy 101.763676 137.936411) (xy 101.76 137.899088) (xy 101.76 136.037333) (xy 101.763677 136) + (xy 101.751395 135.875295) (xy 101.749003 135.851014) (xy 101.705546 135.707753) (xy 101.634974 135.575724) (xy 101.540001 135.459999) + (xy 101.496472 135.424276) (xy 101.424276 135.365026) (xy 101.292247 135.294454) (xy 101.148986 135.250997) (xy 101.037333 135.24) + (xy 101 135.236323) (xy 100.962667 135.24) (xy 98.667164 135.24) (xy 98.795576 135.111588) (xy 99.089417 134.671825) + (xy 99.291817 134.183186) (xy 99.395 133.664449) (xy 99.395 133.135551) (xy 99.372733 133.023608) (xy 99.736975 133.654493) + (xy 99.751434 133.686405) (xy 99.771841 133.714883) (xy 99.771846 133.714892) (xy 99.832896 133.800088) (xy 99.934974 133.895694) + (xy 100.053741 133.969548) (xy 100.184635 134.018813) (xy 100.322625 134.041595) (xy 100.322626 134.041595) (xy 100.462407 134.037019) + (xy 100.598612 134.005261) (xy 100.694081 133.962004) (xy 100.694082 133.962004) (xy 100.726003 133.94754) (xy 100.754489 133.927127) + (xy 100.971803 133.801661) (xy 100.995929 133.843448) (xy 101.133409 133.764074) (xy 101.075303 133.980928) (xy 101.329768 134.427817) + (xy 101.402626 134.529492) (xy 101.493921 134.614998) (xy 101.600143 134.681051) (xy 101.717209 134.725111) (xy 101.840622 134.745487) + (xy 101.965639 134.741395) (xy 102.087456 134.712991) (xy 102.20139 134.661368) (xy 102.3854 134.551582) (xy 102.443507 134.334726) + (xy 101.868882 133.339446) (xy 101.851561 133.349446) (xy 101.827436 133.307661) (xy 102.082048 133.160661) (xy 102.106173 133.202446) + (xy 102.088852 133.212446) (xy 102.663477 134.207726) (xy 102.880334 134.265832) (xy 103.067416 134.161368) (xy 103.16909 134.088509) + (xy 103.254597 133.997215) (xy 103.320649 133.890993) (xy 103.329993 133.866166) (xy 103.356167 133.870487) (xy 103.481184 133.866394) + (xy 103.603 133.837991) (xy 103.716935 133.786368) (xy 103.802257 133.737107) (xy 104.363135 134.297986) (xy 104.392567 134.369041) + (xy 104.483947 134.505801) (xy 104.600253 134.622107) (xy 104.737013 134.713487) (xy 104.888974 134.776431) (xy 105.050294 134.80852) + (xy 105.214774 134.80852) (xy 105.376094 134.776431) (xy 105.528055 134.713487) (xy 105.664815 134.622107) (xy 105.781121 134.505801) + (xy 105.872501 134.369041) (xy 105.935445 134.21708) (xy 105.967534 134.05576) (xy 105.967534 133.89128) (xy 105.935445 133.72996) + (xy 105.872501 133.577999) (xy 105.781121 133.441239) (xy 105.664815 133.324933) (xy 105.528055 133.233553) (xy 105.391915 133.177162) + (xy 104.897597 132.682845) (xy 104.896538 132.650496) (xy 104.868135 132.528679) (xy 104.816511 132.414745) (xy 104.455887 131.790125) + (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) (xy 104.651604 131.677128) (xy 104.7368 131.616078) + (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) (xy 104.978308 131.126349) (xy 104.973731 130.986567) + (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.911452 130.783002) (xy 104.884253 130.722971) (xy 104.863839 130.694483) + (xy 103.694735 128.669537) (xy 103.82105 128.795852) (xy 103.855013 128.846681) (xy 103.971319 128.962987) (xy 104.108079 129.054367) + (xy 104.26004 129.117311) (xy 104.42136 129.1494) (xy 104.58584 129.1494) (xy 104.74716 129.117311) (xy 104.899121 129.054367) + (xy 105.035881 128.962987) (xy 105.152187 128.846681) (xy 105.243567 128.709921) (xy 105.306511 128.55796) (xy 105.30801 128.550422) + (xy 105.30801 129.730687) (xy 105.304334 129.76801) (xy 105.30801 129.805332) (xy 105.30801 129.805342) (xy 105.319007 129.916995) + (xy 105.354071 130.032587) (xy 105.362464 130.060256) (xy 105.433036 130.192286) (xy 105.462346 130.228) (xy 105.528009 130.308011) + (xy 105.557013 130.331814) (xy 107.517122 132.291924) (xy 107.560033 132.395521) (xy 107.651413 132.532281) (xy 107.767719 132.648587) + (xy 107.904479 132.739967) (xy 108.05644 132.802911) (xy 108.21776 132.835) (xy 108.38224 132.835) (xy 108.54356 132.802911) + (xy 108.695521 132.739967) (xy 108.832281 132.648587) (xy 108.948587 132.532281) (xy 109.039967 132.395521) (xy 109.102911 132.24356) + (xy 109.135 132.08224) (xy 109.135 131.91776) (xy 109.102911 131.75644) (xy 109.039967 131.604479) (xy 108.948587 131.467719) + (xy 108.832281 131.351413) (xy 108.695521 131.260033) (xy 108.591924 131.217122) (xy 106.82801 129.453209) (xy 106.82801 126.698472) + (xy 106.870921 126.594875) (xy 106.90301 126.433555) (xy 106.90301 126.269075) (xy 106.870921 126.107755) (xy 106.847881 126.052131) + (xy 106.93575 126.14) (xy 107.65 126.143072) (xy 107.714999 126.13667) (xy 107.714998 128.599949) (xy 107.711322 128.637272) + (xy 107.714998 128.674594) (xy 107.714998 128.674604) (xy 107.725995 128.786257) (xy 107.766155 128.918649) (xy 107.769452 128.929518) + (xy 107.840024 129.061548) (xy 107.879869 129.110098) (xy 107.934997 129.177273) (xy 107.964001 129.201076) (xy 110.137619 131.374695) + (xy 109.971493 131.419208) (xy 109.854426 131.463269) (xy 109.748204 131.529321) (xy 109.65691 131.614828) (xy 109.584051 131.716502) + (xy 109.532428 131.830436) (xy 109.504025 131.952253) (xy 109.499932 132.07727) (xy 109.520308 132.200683) (xy 110.037946 134.132535) + (xy 110.082007 134.249602) (xy 110.148059 134.355824) (xy 110.233566 134.447118) (xy 110.33524 134.519977) (xy 110.449174 134.5716) + (xy 110.570991 134.600003) (xy 110.696008 134.604096) (xy 110.819421 134.58372) (xy 111.996083 134.268434) (xy 114.027956 136.300308) + (xy 114.051754 136.329306) (xy 114.080752 136.353104) (xy 114.167478 136.424279) (xy 114.234305 136.459999) (xy 114.299508 136.494851) + (xy 114.442769 136.538308) (xy 114.554422 136.549305) (xy 114.554432 136.549305) (xy 114.591755 136.552981) (xy 114.629078 136.549305) + (xy 121.923373 136.549305) (xy 121.960695 136.552981) (xy 121.998017 136.549305) (xy 121.998028 136.549305) (xy 122.109681 136.538308) + (xy 122.252942 136.494851) (xy 122.384971 136.424279) (xy 122.500696 136.329306) (xy 122.524498 136.300303) (xy 123.041923 135.782878) + (xy 123.145521 135.739967) (xy 123.282281 135.648587) (xy 123.398587 135.532281) (xy 123.489967 135.395521) (xy 123.552911 135.24356) + (xy 123.585 135.08224) (xy 123.585 134.91776) (xy 123.552911 134.75644) (xy 123.489967 134.604479) (xy 123.398587 134.467719) + (xy 123.282281 134.351413) (xy 123.145521 134.260033) (xy 122.99356 134.197089) (xy 122.865488 134.171613) (xy 122.928117 134.108985) + (xy 122.967719 134.148587) (xy 123.104479 134.239967) (xy 123.25644 134.302911) (xy 123.41776 134.335) (xy 123.58224 134.335) + (xy 123.74356 134.302911) (xy 123.895521 134.239967) (xy 124.032281 134.148587) (xy 124.148587 134.032281) (xy 124.239967 133.895521) + (xy 124.302911 133.74356) (xy 124.332984 133.592374) (xy 125.96571 133.154886) (xy 126.082777 133.110825) (xy 126.188999 133.044773) + (xy 126.280293 132.959266) (xy 126.353152 132.857592) (xy 126.404775 132.743658) (xy 126.433178 132.621841) (xy 126.437271 132.496824) + (xy 126.416895 132.373411) (xy 126.118018 131.257987) (xy 126.711003 130.665002) (xy 126.740001 130.641204) (xy 126.834974 130.525479) + (xy 126.905546 130.39345) (xy 126.949003 130.250189) (xy 126.96 130.138536) (xy 126.96 130.138527) (xy 126.963676 130.101204) + (xy 126.96 130.063881) (xy 126.96 125.313072) (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) + (xy 128.554494 125.205537) (xy 128.651185 125.126185) (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) + (xy 128.91776 125.035) (xy 129.08224 125.035) (xy 129.24356 125.002911) (xy 129.347157 124.96) (xy 129.560199 124.96) + (xy 129.573701 124.973502) (xy 130.711928 126.11173) (xy 130.711928 127.28) (xy 130.724188 127.404482) (xy 130.760498 127.52418) + (xy 130.819463 127.634494) (xy 130.898815 127.731185) (xy 130.995506 127.810537) (xy 131.10582 127.869502) (xy 131.225518 127.905812) + (xy 131.35 127.918072) (xy 131.845674 127.918072) (xy 131.865026 127.954276) (xy 131.902142 127.999502) (xy 131.959999 128.070001) + (xy 131.989003 128.093804) (xy 134.961398 131.0662) (xy 134.437803 131.0662) (xy 133.407279 130.035677) (xy 133.364367 129.932079) + (xy 133.272987 129.795319) (xy 133.156681 129.679013) (xy 133.019921 129.587633) (xy 132.86796 129.524689) (xy 132.70664 129.4926) + (xy 132.54216 129.4926) (xy 132.38084 129.524689) (xy 132.228879 129.587633) (xy 132.092119 129.679013) (xy 131.975813 129.795319) + (xy 131.884433 129.932079) (xy 131.821489 130.08404) (xy 131.7894 130.24536) (xy 131.7894 130.40984) (xy 131.821489 130.57116) + (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) (xy 132.228879 131.067567) (xy 132.332477 131.110479) + (xy 133.559205 132.337208) (xy 133.582999 132.366201) (xy 133.611992 132.389995) (xy 133.611996 132.389999) (xy 133.674055 132.440929) + (xy 133.698724 132.461174) (xy 133.830753 132.531746) (xy 133.974014 132.575203) (xy 134.085667 132.5862) (xy 134.085676 132.5862) + (xy 134.122999 132.589876) (xy 134.160322 132.5862) (xy 142.970643 132.5862) (xy 143.07424 132.629111) (xy 143.23556 132.6612) + (xy 143.40004 132.6612) (xy 143.56136 132.629111) (xy 143.713321 132.566167) (xy 143.850081 132.474787) (xy 143.966387 132.358481) + (xy 144.057767 132.221721) (xy 144.120711 132.06976) (xy 144.1528 131.90844) (xy 144.1528 131.74396) (xy 144.120711 131.58264) + (xy 144.073474 131.4686) (xy 144.524078 131.4686) (xy 144.5614 131.472276) (xy 144.598722 131.4686) (xy 144.598733 131.4686) + (xy 144.710386 131.457603) (xy 144.853647 131.414146) (xy 144.985676 131.343574) (xy 145.101401 131.248601) (xy 145.125203 131.219598) + (xy 145.711002 130.6338) (xy 145.740001 130.610001) (xy 145.834974 130.494276) (xy 145.854326 130.458072) (xy 146.35 130.458072) + (xy 146.474482 130.445812) (xy 146.59418 130.409502) (xy 146.704494 130.350537) (xy 146.801185 130.271185) (xy 146.880537 130.174494) + (xy 146.912872 130.114) (xy 147.441043 130.114) (xy 147.54464 130.156911) (xy 147.70596 130.189) (xy 147.87044 130.189) + (xy 148.03176 130.156911) (xy 148.183721 130.093967) (xy 148.320481 130.002587) (xy 148.436787 129.886281) (xy 148.528167 129.749521) + (xy 148.591111 129.59756) (xy 148.6232 129.43624) (xy 148.6232 129.27176) (xy 148.591111 129.11044) (xy 148.528167 128.958479) + (xy 148.436787 128.821719) (xy 148.320481 128.705413) (xy 148.183721 128.614033) (xy 148.03176 128.551089) (xy 147.87044 128.519) + (xy 147.70596 128.519) (xy 147.54464 128.551089) (xy 147.441043 128.594) (xy 146.988072 128.594) (xy 146.988072 127.82) + (xy 146.975812 127.695518) (xy 146.939502 127.57582) (xy 146.880537 127.465506) (xy 146.801185 127.368815) (xy 146.704494 127.289463) + (xy 146.59418 127.230498) (xy 146.474482 127.194188) (xy 146.35 127.181928) (xy 145.230748 127.181928) (xy 145.362953 126.862756) + (xy 145.445 126.450279) (xy 145.445 126.029721) (xy 145.362953 125.617244) (xy 145.202012 125.228698) (xy 145.164985 125.173283) + (xy 145.330779 125.104609) (xy 145.590379 124.93115) (xy 145.81115 124.710379) (xy 145.984609 124.450779) (xy 146.104089 124.162327) + (xy 146.165 123.856109) (xy 146.165 123.543891) (xy 146.104089 123.237673) (xy 145.984609 122.949221) (xy 145.81115 122.689621) + (xy 145.590379 122.46885) (xy 145.330779 122.295391) (xy 145.042327 122.175911) (xy 144.736109 122.115) (xy 144.423891 122.115) + (xy 144.117673 122.175911) (xy 144.023303 122.215) (xy 143.85374 122.215) (xy 143.566842 122.272068) (xy 143.296589 122.38401) + (xy 143.053368 122.546525) (xy 142.846525 122.753368) (xy 142.68401 122.996589) (xy 142.572068 123.266842) (xy 142.515 123.55374) + (xy 142.515 123.84626) (xy 142.572068 124.133158) (xy 142.607988 124.219876) (xy 142.298698 124.347988) (xy 142.076252 124.496622) + (xy 142.081817 124.483186) (xy 142.185 123.964449) (xy 142.185 123.435551) (xy 142.081817 122.916814) (xy 141.879417 122.428175) + (xy 141.585576 121.988412) (xy 141.261364 121.6642) (xy 145.299401 121.6642) (xy 153.500204 129.865004) (xy 153.524002 129.894002) + (xy 153.639727 129.988975) (xy 153.771756 130.059547) (xy 153.915017 130.103004) (xy 154.02667 130.114001) (xy 154.026679 130.114001) + (xy 154.064002 130.117677) (xy 154.101325 130.114001) (xy 169.757177 130.114001) (xy 169.794499 130.117677) (xy 169.831821 130.114001) + (xy 169.831832 130.114001) (xy 169.943485 130.103004) (xy 170.086746 130.059547) (xy 170.218775 129.988975) (xy 170.3345 129.894002) + (xy 170.358302 129.864999) (xy 170.6245 129.598801) (xy 173.159701 132.134003) (xy 173.183499 132.163001) (xy 173.212497 132.186799) + (xy 173.299223 132.257974) (xy 173.431253 132.328546) (xy 173.574514 132.372003) (xy 173.686167 132.383) (xy 173.686176 132.383) + (xy 173.723499 132.386676) (xy 173.760822 132.383) (xy 177.717843 132.383) (xy 177.82144 132.425911) (xy 177.98276 132.458) + (xy 178.14724 132.458) (xy 178.30856 132.425911) (xy 178.460521 132.362967) (xy 178.597281 132.271587) (xy 178.713587 132.155281) + (xy 178.804967 132.018521) (xy 178.867911 131.86656) (xy 178.891494 131.748) (xy 181.194678 131.748) (xy 181.232 131.751676) + (xy 181.269322 131.748) (xy 181.269333 131.748) (xy 181.380986 131.737003) (xy 181.524247 131.693546) (xy 181.656276 131.622974) + (xy 181.772001 131.528001) (xy 181.795804 131.498997) (xy 182.736729 130.558072) (xy 184.45 130.558072) (xy 184.574482 130.545812) + (xy 184.69418 130.509502) (xy 184.804494 130.450537) (xy 184.901185 130.371185) (xy 184.980537 130.274494) (xy 185.039502 130.16418) + (xy 185.075812 130.044482) (xy 185.088072 129.92) (xy 185.088072 128.343229) (xy 194.671302 118.76) (xy 202.891678 118.76) + (xy 202.929 118.763676) (xy 202.966322 118.76) (xy 202.966333 118.76) (xy 203.077986 118.749003) (xy 203.221247 118.705546) + (xy 203.353276 118.634974) (xy 203.469001 118.540001) (xy 203.492803 118.510998) (xy 204.743813 117.25999) (xy 209.652843 117.25999) + (xy 209.75644 117.302901) (xy 209.91776 117.33499) (xy 210.08224 117.33499) (xy 210.24356 117.302901) (xy 210.395521 117.239957) + (xy 210.402955 117.23499) (xy 221.07053 117.23499) (xy 221.107852 117.238666) (xy 221.145174 117.23499) (xy 221.145185 117.23499) + (xy 221.256838 117.223993) (xy 221.400099 117.180536) (xy 221.532128 117.109964) (xy 221.647853 117.014991) (xy 221.671656 116.985987) + (xy 221.960997 116.696646) (xy 221.990001 116.672843) (xy 222.084974 116.557118) (xy 222.155546 116.425089) (xy 222.199003 116.281828) + (xy 222.201343 116.258072) (xy 222.6 116.258072) (xy 222.724482 116.245812) (xy 222.84418 116.209502) (xy 222.954494 116.150537) + (xy 223.051185 116.071185) (xy 223.130537 115.974494) (xy 223.189502 115.86418) (xy 223.225812 115.744482) (xy 223.238072 115.62) + (xy 223.238072 114.05673) (xy 223.361004 113.933798) (xy 223.390001 113.910001) (xy 223.416332 113.877917) (xy 223.484974 113.794277) + (xy 223.555546 113.662247) (xy 223.566009 113.627754) (xy 223.599003 113.518986) (xy 223.61 113.407333) (xy 223.61 113.407323) + (xy 223.613676 113.37) (xy 223.61 113.332677) (xy 223.61 107.387325) (xy 223.613676 107.35) (xy 223.61 107.312675) + (xy 223.61 107.312667) (xy 223.599003 107.201014) (xy 223.555546 107.057753) (xy 223.484974 106.925724) (xy 223.390001 106.809999) + (xy 223.361003 106.786201) (xy 222.035009 105.460208) (xy 222.035009 101.275922) (xy 222.038685 101.238599) (xy 222.035009 101.201276) + (xy 222.035009 101.201266) (xy 222.024012 101.089613) (xy 221.980555 100.946352) (xy 221.909983 100.814323) (xy 221.81501 100.698598) + (xy 221.786011 100.674799) (xy 221.51 100.398789) (xy 221.51 98.097157) (xy 221.552911 97.99356) (xy 221.585 97.83224) + (xy 221.585 97.66776) (xy 221.552911 97.50644) (xy 221.51 97.402843) (xy 221.51 97.258072) (xy 222.55 97.258072) + (xy 222.674482 97.245812) (xy 222.79418 97.209502) (xy 222.904494 97.150537) (xy 223.001185 97.071185) (xy 223.080537 96.974494) + (xy 223.139502 96.86418) (xy 223.175812 96.744482) (xy 223.188072 96.62) (xy 223.188072 94.62) (xy 223.175812 94.495518) + (xy 223.139502 94.37582) (xy 223.080537 94.265506) (xy 223.001185 94.168815) (xy 222.904494 94.089463) (xy 222.815001 94.041627) + (xy 222.815001 80.017314) (xy 222.818677 79.979991) (xy 222.815001 79.942668) (xy 222.815001 79.942658) (xy 222.804004 79.831005) + (xy 222.760547 79.687744) (xy 222.689975 79.555715) (xy 222.595002 79.43999) (xy 222.566004 79.416192) (xy 221.332879 78.183068) + (xy 221.31 78.127833) (xy 221.31 78.058072) (xy 222.55 78.058072) (xy 222.674482 78.045812) (xy 222.79418 78.009502) + (xy 222.904494 77.950537) (xy 223.001185 77.871185) (xy 223.080537 77.774494) (xy 223.139502 77.66418) (xy 223.175812 77.544482) + (xy 223.188072 77.42) (xy 223.188072 75.42) (xy 223.175812 75.295518) (xy 223.139502 75.17582) (xy 223.080537 75.065506) + (xy 223.001185 74.968815) (xy 222.904494 74.889463) (xy 222.79418 74.830498) (xy 222.674482 74.794188) (xy 222.55 74.781928) + (xy 222.16 74.781928) (xy 222.16 72.881803) (xy 222.566005 72.475799) (xy 222.595002 72.452002) (xy 222.689975 72.336277) + (xy 222.760547 72.204248) (xy 222.804004 72.060987) (xy 222.815001 71.949334) (xy 222.815001 71.949325) (xy 222.818677 71.912002) + (xy 222.815001 71.874679) (xy 222.815001 61.342334) (xy 222.818678 61.305001) (xy 222.804004 61.156015) (xy 222.760547 61.012754) + (xy 222.689975 60.880725) (xy 222.648794 60.830546) (xy 222.595002 60.765) (xy 222.566004 60.741202) (xy 221.282879 59.458078) + (xy 221.26 59.402843) (xy 221.26 59.158072) (xy 222.65 59.158072) (xy 222.774482 59.145812) (xy 222.89418 59.109502) + (xy 223.004494 59.050537) (xy 223.101185 58.971185) (xy 223.180537 58.874494) (xy 223.239502 58.76418) (xy 223.275812 58.644482) + (xy 223.288072 58.52) (xy 223.288072 56.52) (xy 223.275812 56.395518) (xy 223.239502 56.27582) (xy 223.180537 56.165506) + (xy 223.101185 56.068815) (xy 223.004494 55.989463) (xy 222.89418 55.930498) (xy 222.774482 55.894188) (xy 222.65 55.881928) + (xy 221.530748 55.881928) (xy 221.662953 55.562756) (xy 221.745 55.150279) (xy 221.745 54.729721) (xy 221.662953 54.317244) + (xy 221.502012 53.928698) (xy 221.464985 53.873283) (xy 221.630779 53.804609) (xy 221.890379 53.63115) (xy 222.11115 53.410379) + (xy 222.284609 53.150779) (xy 222.404089 52.862327) (xy 222.465 52.556109) (xy 222.465 52.243891) (xy 222.404089 51.937673) + (xy 222.284609 51.649221) (xy 222.11115 51.389621) (xy 221.890379 51.16885) (xy 221.630779 50.995391) (xy 221.342327 50.875911) + (xy 221.036109 50.815) (xy 220.723891 50.815) (xy 220.417673 50.875911) (xy 220.323303 50.915) (xy 220.15374 50.915) + (xy 219.866842 50.972068) (xy 219.596589 51.08401) (xy 219.353368 51.246525) (xy 219.146525 51.453368) (xy 218.98401 51.696589) + (xy 218.872068 51.966842) (xy 218.815 52.25374) (xy 218.815 52.54626) (xy 218.872068 52.833158) (xy 218.907988 52.919876) + (xy 218.598698 53.047988) (xy 218.376252 53.196622) (xy 218.381817 53.183186) (xy 218.485 52.664449) (xy 218.485 52.135551) + (xy 218.381817 51.616814) (xy 218.179417 51.128175) (xy 217.885576 50.688412) (xy 217.511588 50.314424) (xy 217.071825 50.020583) + (xy 216.687522 49.8614) (xy 217.415123 49.8614) (xy 217.45 49.864835) (xy 217.484877 49.8614) (xy 217.589184 49.851127) + (xy 217.72302 49.810528) (xy 217.846363 49.7446) (xy 217.954475 49.655875) (xy 218.0432 49.547763) (xy 218.109128 49.42442) + (xy 218.149727 49.290584) (xy 218.163435 49.1514) (xy 218.16 49.116523) (xy 218.16 47.628) (xy 218.327 47.628) + (xy 218.327 47.648) (xy 218.347 47.648) (xy 218.347 47.902) (xy 218.327 47.902) (xy 218.327 48.75125) + (xy 218.48575 48.91) (xy 219 48.913072) (xy 219.124482 48.900812) (xy 219.24418 48.864502) (xy 219.354494 48.805537) + (xy 219.451185 48.726185) (xy 219.530537 48.629494) (xy 219.589502 48.51918) (xy 219.625812 48.399482) (xy 219.638072 48.275) + (xy 219.635 48.06075) (xy 219.476252 47.902002) (xy 219.635 47.902002) (xy 219.635 47.804614) (xy 219.64356 47.802911) + (xy 219.795521 47.739967) (xy 219.932281 47.648587) (xy 220.048587 47.532281) (xy 220.139967 47.395521) (xy 220.202911 47.24356) + (xy 220.235 47.08224) (xy 220.235 46.91776) (xy 220.202911 46.75644) (xy 220.139967 46.604479) (xy 220.048587 46.467719) + (xy 219.932281 46.351413) (xy 219.795521 46.260033) (xy 219.691923 46.217122) (xy 219.638072 46.16327) (xy 219.638072 45.525) + (xy 219.625812 45.400518) (xy 219.589502 45.28082) (xy 219.530537 45.170506) (xy 219.451185 45.073815) (xy 219.354494 44.994463) + (xy 219.24418 44.935498) (xy 219.16 44.909962) (xy 219.16 44.747157) (xy 219.202911 44.64356) (xy 219.235 44.48224) + (xy 219.235 44.31776) (xy 219.202911 44.15644) (xy 219.139967 44.004479) (xy 219.048587 43.867719) (xy 218.932281 43.751413) + (xy 218.795521 43.660033) (xy 218.64356 43.597089) (xy 218.48224 43.565) (xy 218.31776 43.565) (xy 218.15644 43.597089) + (xy 218.004479 43.660033) (xy 217.867719 43.751413) (xy 217.751413 43.867719) (xy 217.67743 43.978442) (xy 217.589184 43.951673) + (xy 217.484877 43.9414) (xy 217.45 43.937965) (xy 217.415123 43.9414) (xy 213.984877 43.9414) (xy 213.95 43.937965) + (xy 213.915123 43.9414) (xy 213.810816 43.951673) (xy 213.67698 43.992272) (xy 213.553637 44.0582) (xy 213.445525 44.146925) + (xy 213.3568 44.255037) (xy 213.290872 44.37838) (xy 213.250273 44.512216) (xy 213.236565 44.6514) (xy 213.240001 44.686287) + (xy 213.240001 44.886928) (xy 212.6 44.886928) (xy 212.475518 44.899188) (xy 212.35582 44.935498) (xy 212.245506 44.994463) + (xy 212.148815 45.073815) (xy 212.094499 45.14) (xy 211.818466 45.14) (xy 211.788641 45.137063) (xy 210.430332 43.778754) + (xy 210.402617 43.744983) (xy 210.267859 43.634389) (xy 210.114113 43.552211) (xy 209.94729 43.501605) (xy 209.817277 43.4888) + (xy 209.817269 43.4888) (xy 209.7738 43.484519) (xy 209.730331 43.4888) (xy 206.365023 43.4888) (xy 206.239249 43.385579) + (xy 206.085503 43.303401) (xy 205.91868 43.252795) (xy 205.788667 43.23999) (xy 205.788659 43.23999) (xy 205.74519 43.235709) + (xy 205.701721 43.23999) (xy 194.668479 43.23999) (xy 194.62501 43.235709) (xy 194.581541 43.23999) (xy 194.581533 43.23999) + (xy 194.45152 43.252795) (xy 194.284697 43.303401) (xy 194.130951 43.385579) (xy 193.996193 43.496173) (xy 193.968476 43.529946) + (xy 193.704956 43.793466) (xy 193.671183 43.821183) (xy 193.645482 43.8525) (xy 193.379079 43.8525) (xy 188.334046 38.807468) + (xy 188.181533 38.654955) (xy 188.153816 38.621182) (xy 188.019058 38.510588) (xy 187.865312 38.42841) (xy 187.698489 38.377804) + (xy 187.568476 38.364999) (xy 187.568468 38.364999) (xy 187.524999 38.360718) (xy 187.48153 38.364999) (xy 175.75099 38.364999) + (xy 175.707524 38.360718) (xy 175.664058 38.364999) (xy 175.664048 38.364999) (xy 175.534035 38.377804) (xy 175.367212 38.42841) + (xy 175.213466 38.510588) (xy 175.078708 38.621182) (xy 175.050991 38.654955) (xy 174.952736 38.75321) (xy 169.314789 38.75321) + (xy 168.345046 37.783468) (xy 168.244059 37.70059) (xy 168.090313 37.618412) (xy 168.075496 37.613917) (xy 166.482013 36.020435) + (xy 166.454296 35.986662) (xy 166.319538 35.876068) (xy 166.165792 35.79389) (xy 165.998969 35.743284) (xy 165.868956 35.730479) + (xy 165.868948 35.730479) (xy 165.825479 35.726198) (xy 165.78201 35.730479) (xy 156.517987 35.730479) (xy 156.47452 35.726198) + (xy 156.431054 35.730479) (xy 156.431044 35.730479) (xy 156.301031 35.743284) (xy 156.134208 35.79389) (xy 155.980462 35.876068) + (xy 155.845704 35.986662) (xy 155.817987 36.020435) (xy 155.404952 36.43347) (xy 155.371184 36.461183) (xy 155.260589 36.595941) + (xy 155.178411 36.749687) (xy 155.127805 36.91651) (xy 155.115 37.046523) (xy 155.115 37.046531) (xy 155.110719 37.09) + (xy 155.115 37.133469) (xy 155.115 37.557317) (xy 155.045506 37.594463) (xy 154.948815 37.673815) (xy 154.869463 37.770506) + (xy 154.818954 37.865) (xy 153.825476 37.865) (xy 153.782 37.860718) (xy 153.738523 37.865) (xy 137.368479 37.865) + (xy 137.32501 37.860719) (xy 137.281541 37.865) (xy 137.281533 37.865) (xy 137.15152 37.877805) (xy 136.984697 37.928411) + (xy 136.857903 37.996183) (xy 136.830951 38.010589) (xy 136.729963 38.093468) (xy 136.729961 38.09347) (xy 136.696193 38.121183) + (xy 136.66848 38.154951) (xy 134.904958 39.918474) (xy 134.904953 39.918478) (xy 134.904951 39.91848) (xy 134.871183 39.946193) + (xy 134.84347 39.979961) (xy 134.308432 40.515) (xy 127.643465 40.515) (xy 127.599999 40.510719) (xy 127.556533 40.515) + (xy 118.643465 40.515) (xy 118.599999 40.510719) (xy 118.556533 40.515) (xy 118.556523 40.515) (xy 118.42651 40.527805) + (xy 118.259687 40.578411) (xy 118.105941 40.660589) (xy 118.097828 40.667247) (xy 118.004953 40.743468) (xy 118.004951 40.74347) + (xy 117.971183 40.771183) (xy 117.94347 40.804951) (xy 116.833423 41.914999) (xy 116.131464 41.914999) (xy 116.087998 41.910718) + (xy 116.044532 41.914999) (xy 116.044522 41.914999) (xy 115.914509 41.927804) (xy 115.747686 41.97841) (xy 115.59394 42.060588) + (xy 115.459182 42.171182) (xy 115.431465 42.204955) (xy 115.154955 42.481465) (xy 115.121182 42.509182) (xy 115.010588 42.643941) + (xy 114.92841 42.797687) (xy 114.896094 42.904217) (xy 114.877804 42.964509) (xy 114.876211 42.980685) (xy 114.864999 43.094523) + (xy 114.864999 43.09453) (xy 114.860718 43.137999) (xy 114.864999 43.181469) (xy 114.864999 43.615) (xy 113.793465 43.615) + (xy 113.749999 43.610719) (xy 113.706533 43.615) (xy 113.706523 43.615) (xy 113.57651 43.627805) (xy 113.409687 43.678411) + (xy 113.255941 43.760589) (xy 113.244474 43.77) (xy 113.154953 43.843468) (xy 113.154951 43.84347) (xy 113.121183 43.871183) + (xy 113.09347 43.904951) (xy 111.129958 45.868464) (xy 111.129953 45.868468) (xy 110.015389 46.983032) (xy 109.986451 46.902722) + (xy 109.924471 46.786765) (xy 109.68438 46.719785) (xy 108.89842 47.505745) (xy 108.912563 47.519888) (xy 108.732958 47.699493) + (xy 108.718815 47.68535) (xy 108.704673 47.699493) (xy 108.525068 47.519888) (xy 108.53921 47.505745) (xy 108.525068 47.491603) + (xy 108.704673 47.311998) (xy 108.718815 47.32614) (xy 109.504775 46.54018) (xy 109.437795 46.300089) (xy 109.302055 46.23626) + (xy 109.380542 46.20375) (xy 109.60935 46.050865) (xy 109.803935 45.85628) (xy 109.95682 45.627472) (xy 110.062129 45.373235) + (xy 110.115815 45.103337) (xy 110.115815 44.828153) (xy 110.062129 44.558255) (xy 109.95682 44.304018) (xy 109.803935 44.07521) + (xy 109.60935 43.880625) (xy 109.380542 43.72774) (xy 109.3033 43.695745) (xy 109.380542 43.66375) (xy 109.60935 43.510865) + (xy 109.803935 43.31628) (xy 109.95682 43.087472) (xy 110.062129 42.833235) (xy 110.115815 42.563337) (xy 110.115815 42.288153) + (xy 110.062129 42.018255) (xy 109.95682 41.764018) (xy 109.803935 41.53521) (xy 109.60935 41.340625) (xy 109.380542 41.18774) + (xy 109.126305 41.082431) (xy 108.856407 41.028745) (xy 108.804337 41.028745) (xy 108.763314 40.82251) (xy 108.658005 40.568273) + (xy 108.50512 40.339465) (xy 108.310535 40.14488) (xy 108.081727 39.991995) (xy 107.82749 39.886686) (xy 107.557592 39.833) + (xy 107.282408 39.833) (xy 107.01251 39.886686) (xy 106.758273 39.991995) (xy 106.529465 40.14488) (xy 106.33488 40.339465) + (xy 106.181995 40.568273) (xy 106.076686 40.82251) (xy 106.071225 40.849967) (xy 105.991928 40.817121) (xy 105.89381 40.719003) + (xy 105.870007 40.689999) (xy 105.754282 40.595026) (xy 105.622253 40.524454) (xy 105.478992 40.480997) (xy 105.367339 40.47) + (xy 105.367328 40.47) (xy 105.330006 40.466324) (xy 105.292684 40.47) (xy 93.352341 40.47) (xy 93.26512 40.339465) + (xy 93.070535 40.14488) (xy 92.841727 39.991995) (xy 92.58749 39.886686) (xy 92.317592 39.833) (xy 92.042408 39.833) + (xy 91.77251 39.886686) (xy 91.518273 39.991995) (xy 91.289465 40.14488) (xy 91.09488 40.339465) (xy 90.941995 40.568273) + (xy 90.836686 40.82251) (xy 90.783 41.092408) (xy 90.783 41.367592) (xy 90.836686 41.63749) (xy 90.941995 41.891727) + (xy 91.09488 42.120535) (xy 91.289465 42.31512) (xy 91.518273 42.468005) (xy 91.595515 42.5) (xy 91.518273 42.531995) + (xy 91.289465 42.68488) (xy 91.09488 42.879465) (xy 90.941995 43.108273) (xy 90.836686 43.36251) (xy 90.783 43.632408) + (xy 90.783 43.907592) (xy 90.836686 44.17749) (xy 90.941995 44.431727) (xy 91.09488 44.660535) (xy 91.289465 44.85512) + (xy 91.518273 45.008005) (xy 91.589943 45.037692) (xy 91.576977 45.042364) (xy 91.46102 45.104344) (xy 91.39404 45.344435) + (xy 92.18 46.130395) (xy 92.96596 45.344435) (xy 92.956048 45.308907) (xy 93.29921 44.965745) (xy 93.285068 44.951603) + (xy 93.464673 44.771998) (xy 93.478815 44.78614) (xy 93.492958 44.771998) (xy 93.672563 44.951603) (xy 93.65842 44.965745) + (xy 94.44438 45.751705) (xy 94.684471 45.684725) (xy 94.801571 45.435697) (xy 94.867838 45.16861) (xy 94.875429 45.006688) + (xy 95.01776 45.035) (xy 95.18224 45.035) (xy 95.34356 45.002911) (xy 95.495521 44.939967) (xy 95.632281 44.848587) + (xy 95.748587 44.732281) (xy 95.839967 44.595521) (xy 95.867107 44.53) (xy 105.049889 44.53) (xy 105.051413 44.532281) + (xy 105.167719 44.648587) (xy 105.304479 44.739967) (xy 105.45644 44.802911) (xy 105.61776 44.835) (xy 105.78224 44.835) + (xy 105.94356 44.802911) (xy 106.095521 44.739967) (xy 106.232281 44.648587) (xy 106.348587 44.532281) (xy 106.351882 44.52735) + (xy 106.454435 44.55596) (xy 107.240395 43.77) (xy 107.226253 43.755858) (xy 107.405858 43.576253) (xy 107.42 43.590395) + (xy 107.434143 43.576253) (xy 107.613748 43.755858) (xy 107.599605 43.77) (xy 107.613748 43.784143) (xy 107.434143 43.963748) + (xy 107.42 43.949605) (xy 106.63404 44.735565) (xy 106.70102 44.975656) (xy 106.83676 45.039485) (xy 106.758273 45.071995) + (xy 106.529465 45.22488) (xy 106.33488 45.419465) (xy 106.321159 45.44) (xy 105.737322 45.44) (xy 105.699999 45.436324) + (xy 105.662676 45.44) (xy 105.662667 45.44) (xy 105.551014 45.450997) (xy 105.407753 45.494454) (xy 105.275724 45.565026) + (xy 105.159999 45.659999) (xy 105.136201 45.688997) (xy 104.079454 46.745745) (xy 94.651156 46.745745) (xy 94.563935 46.61521) + (xy 94.36935 46.420625) (xy 94.140542 46.26774) (xy 94.068872 46.238053) (xy 94.081838 46.233381) (xy 94.197795 46.171401) + (xy 94.264775 45.93131) (xy 93.478815 45.14535) (xy 92.692855 45.93131) (xy 92.702767 45.966838) (xy 92.359605 46.31) + (xy 92.373748 46.324143) (xy 92.194143 46.503748) (xy 92.18 46.489605) (xy 91.39404 47.275565) (xy 91.46102 47.515656) + (xy 91.591644 47.577079) (xy 91.576977 47.582364) (xy 91.46102 47.644344) (xy 91.39404 47.884435) (xy 92.18 48.670395) + (xy 92.194143 48.656253) (xy 92.373748 48.835858) (xy 92.359605 48.85) (xy 92.373748 48.864143) (xy 92.194143 49.043748) + (xy 92.18 49.029605) (xy 91.39404 49.815565) (xy 91.46102 50.055656) (xy 91.59676 50.119485) (xy 91.518273 50.151995) + (xy 91.289465 50.30488) (xy 91.09488 50.499465) (xy 90.941995 50.728273) (xy 90.836686 50.98251) (xy 90.783 51.252408) + (xy 90.783 51.527592) (xy 90.836686 51.79749) (xy 90.941995 52.051727) (xy 91.09488 52.280535) (xy 91.289465 52.47512) + (xy 91.518273 52.628005) (xy 91.595515 52.66) (xy 91.518273 52.691995) (xy 91.289465 52.84488) (xy 91.09488 53.039465) + (xy 90.941995 53.268273) (xy 90.836686 53.52251) (xy 90.783 53.792408) (xy 90.783 54.067592) (xy 90.836686 54.33749) + (xy 90.941995 54.591727) (xy 91.09488 54.820535) (xy 91.289465 55.01512) (xy 91.518273 55.168005) (xy 91.595515 55.2) + (xy 91.518273 55.231995) (xy 91.289465 55.38488) (xy 91.09488 55.579465) (xy 90.941995 55.808273) (xy 90.836686 56.06251) + (xy 90.783 56.332408) (xy 90.783 56.607592) (xy 90.836686 56.87749) (xy 90.941995 57.131727) (xy 91.09488 57.360535) + (xy 91.289465 57.55512) (xy 91.518273 57.708005) (xy 91.595515 57.74) (xy 91.518273 57.771995) (xy 91.289465 57.92488) + (xy 91.09488 58.119465) (xy 90.941995 58.348273) (xy 90.836686 58.60251) (xy 90.783 58.872408) (xy 90.783 59.147592) + (xy 90.836686 59.41749) (xy 90.941995 59.671727) (xy 91.09488 59.900535) (xy 91.289465 60.09512) (xy 91.518273 60.248005) + (xy 91.595515 60.28) (xy 91.518273 60.311995) (xy 91.289465 60.46488) (xy 91.09488 60.659465) (xy 90.941995 60.888273) + (xy 90.836686 61.14251) (xy 90.783 61.412408) (xy 90.783 61.687592) (xy 90.836686 61.95749) (xy 90.941995 62.211727) + (xy 91.09488 62.440535) (xy 91.289465 62.63512) (xy 91.518273 62.788005) (xy 91.595515 62.82) (xy 91.518273 62.851995) + (xy 91.289465 63.00488) (xy 91.09488 63.199465) (xy 90.941995 63.428273) (xy 90.836686 63.68251) (xy 90.783 63.952408) + (xy 90.783 64.227592) (xy 90.836686 64.49749) (xy 90.941995 64.751727) (xy 91.09488 64.980535) (xy 91.289465 65.17512) + (xy 91.518273 65.328005) (xy 91.595515 65.36) (xy 91.518273 65.391995) (xy 91.289465 65.54488) (xy 91.09488 65.739465) + (xy 90.941995 65.968273) (xy 90.836686 66.22251) (xy 90.783 66.492408) (xy 90.783 66.767592) (xy 90.836686 67.03749) + (xy 90.941995 67.291727) (xy 91.09488 67.520535) (xy 91.289465 67.71512) (xy 91.518273 67.868005) (xy 91.595515 67.9) + (xy 91.518273 67.931995) (xy 91.289465 68.08488) (xy 91.09488 68.279465) (xy 90.941995 68.508273) (xy 90.836686 68.76251) + (xy 90.783 69.032408) (xy 90.783 69.307592) (xy 90.836686 69.57749) (xy 90.941995 69.831727) (xy 91.09488 70.060535) + (xy 91.289465 70.25512) (xy 91.518273 70.408005) (xy 91.77251 70.513314) (xy 92.042408 70.567) (xy 92.094478 70.567) + (xy 92.135501 70.773235) (xy 92.24081 71.027472) (xy 92.393695 71.25628) (xy 92.58828 71.450865) (xy 92.817088 71.60375) + (xy 93.071325 71.709059) (xy 93.341223 71.762745) (xy 93.616407 71.762745) (xy 93.886305 71.709059) (xy 94.04 71.645396) + (xy 94.040001 73.544048) (xy 93.4285 73.544048) (xy 93.304018 73.556308) (xy 93.18432 73.592618) (xy 93.074006 73.651583) + (xy 92.977315 73.730935) (xy 92.897963 73.827626) (xy 92.838998 73.93794) (xy 92.802688 74.057638) (xy 92.790428 74.18212) + (xy 92.790428 74.81712) (xy 92.802688 74.941602) (xy 92.820403 75) (xy 92.802688 75.058398) (xy 92.790428 75.18288) + (xy 92.790428 75.81788) (xy 92.802688 75.942362) (xy 92.838998 76.06206) (xy 92.897963 76.172374) (xy 92.977315 76.269065) + (xy 93.074006 76.348417) (xy 93.18432 76.407382) (xy 93.24 76.424272) (xy 93.240001 80.935197) (xy 92.36401 81.811189) + (xy 92.335009 81.834989) (xy 92.311211 81.863987) (xy 92.065995 82.109203) (xy 91.991111 82.086487) (xy 91.77295 82.065) + (xy 90.974885 82.065) (xy 91.042252 82.019987) (xy 91.269987 81.792252) (xy 91.448918 81.524463) (xy 91.572168 81.226912) + (xy 91.635 80.911033) (xy 91.635 80.588967) (xy 91.572168 80.273088) (xy 91.448918 79.975537) (xy 91.269987 79.707748) + (xy 91.042252 79.480013) (xy 90.774463 79.301082) (xy 90.476912 79.177832) (xy 90.161033 79.115) (xy 89.838967 79.115) + (xy 89.523088 79.177832) (xy 89.225537 79.301082) (xy 88.959613 79.478767) (xy 88.959539 75.470069) (xy 89.044193 75.385415) + (xy 89.139956 75.649814) (xy 89.429571 75.790704) (xy 89.741108 75.872384) (xy 90.062595 75.891718) (xy 90.381675 75.847961) + (xy 90.686088 75.742795) (xy 90.860044 75.649814) (xy 90.955808 75.385413) (xy 90 74.429605) (xy 89.985858 74.443748) + (xy 89.806253 74.264143) (xy 89.820395 74.25) (xy 90.179605 74.25) (xy 91.135413 75.205808) (xy 91.399814 75.110044) + (xy 91.540704 74.820429) (xy 91.622384 74.508892) (xy 91.641718 74.187405) (xy 91.597961 73.868325) (xy 91.492795 73.563912) + (xy 91.399814 73.389956) (xy 91.135413 73.294192) (xy 90.179605 74.25) (xy 89.820395 74.25) (xy 89.806253 74.235858) + (xy 89.985858 74.056253) (xy 90 74.070395) (xy 90.955808 73.114587) (xy 90.860044 72.850186) (xy 90.570429 72.709296) + (xy 90.258892 72.627616) (xy 89.937405 72.608282) (xy 89.618325 72.652039) (xy 89.313912 72.757205) (xy 89.139956 72.850186) + (xy 89.044193 73.114585) (xy 88.959493 73.029885) (xy 88.959049 48.922017) (xy 90.77809 48.922017) (xy 90.819078 49.194133) + (xy 90.912364 49.453023) (xy 90.974344 49.56898) (xy 91.214435 49.63596) (xy 92.000395 48.85) (xy 91.214435 48.06404) + (xy 90.974344 48.13102) (xy 90.857244 48.380048) (xy 90.790977 48.647135) (xy 90.77809 48.922017) (xy 88.959049 48.922017) + (xy 88.959003 46.382017) (xy 90.77809 46.382017) (xy 90.819078 46.654133) (xy 90.912364 46.913023) (xy 90.974344 47.02898) + (xy 91.214435 47.09596) (xy 92.000395 46.31) (xy 91.214435 45.52404) (xy 90.974344 45.59102) (xy 90.857244 45.840048) + (xy 90.790977 46.107135) (xy 90.77809 46.382017) (xy 88.959003 46.382017) (xy 88.958857 38.511863) (xy 88.971894 38.382509) + (xy 88.998593 38.296493) (xy 89.041067 38.218238) (xy 89.097851 38.149414) (xy 89.16667 38.092633) (xy 89.244936 38.05015) + (xy 89.33096 38.023445) (xy 89.473606 38.009063) (xy 149.013379 35.685) (xy 170.896299 35.685) + ) + ) + (filled_polygon + (pts + (xy 173.005405 121.897808) (xy 173.029199 121.926801) (xy 173.058192 121.950595) (xy 173.058196 121.950599) (xy 173.116778 121.998675) + (xy 173.144924 122.021774) (xy 173.276953 122.092346) (xy 173.420214 122.135803) (xy 173.531867 122.1468) (xy 173.531876 122.1468) + (xy 173.569199 122.150476) (xy 173.606522 122.1468) (xy 175.47541 122.1468) (xy 175.220583 122.528175) (xy 175.018183 123.016814) + (xy 174.915 123.535551) (xy 174.915 124.064449) (xy 175.018183 124.583186) (xy 175.023749 124.596623) (xy 174.801302 124.447989) + (xy 174.492012 124.319877) (xy 174.527932 124.233158) (xy 174.585 123.94626) (xy 174.585 123.65374) (xy 174.527932 123.366842) + (xy 174.41599 123.096589) (xy 174.253475 122.853368) (xy 174.046632 122.646525) (xy 173.803411 122.48401) (xy 173.533158 122.372068) + (xy 173.24626 122.315) (xy 173.076697 122.315) (xy 172.982327 122.275911) (xy 172.676109 122.215) (xy 172.363891 122.215) + (xy 172.057673 122.275911) (xy 171.769221 122.395391) (xy 171.509621 122.56885) (xy 171.28885 122.789621) (xy 171.115391 123.049221) + (xy 170.995911 123.337673) (xy 170.935 123.643891) (xy 170.935 123.956109) (xy 170.995911 124.262327) (xy 171.115391 124.550779) + (xy 171.243113 124.741928) (xy 169.45 124.741928) (xy 169.325518 124.754188) (xy 169.20582 124.790498) (xy 169.095506 124.849463) + (xy 168.998815 124.928815) (xy 168.919463 125.025506) (xy 168.860498 125.13582) (xy 168.824188 125.255518) (xy 168.811928 125.38) + (xy 168.811928 127.38) (xy 168.824188 127.504482) (xy 168.860498 127.62418) (xy 168.919463 127.734494) (xy 168.998815 127.831185) + (xy 169.095506 127.910537) (xy 169.20582 127.969502) (xy 169.325518 128.005812) (xy 169.45 128.018072) (xy 169.84 128.018072) + (xy 169.84 128.233697) (xy 169.479697 128.594001) (xy 164.4408 128.594001) (xy 164.811002 128.2238) (xy 164.840001 128.200001) + (xy 164.934974 128.084276) (xy 164.954326 128.048072) (xy 165.45 128.048072) (xy 165.574482 128.035812) (xy 165.69418 127.999502) + (xy 165.804494 127.940537) (xy 165.901185 127.861185) (xy 165.980537 127.764494) (xy 166.039502 127.65418) (xy 166.075812 127.534482) + (xy 166.088072 127.41) (xy 166.088072 127.17) (xy 166.813721 127.17) (xy 166.94484 127.224311) (xy 167.10616 127.2564) + (xy 167.27064 127.2564) (xy 167.43196 127.224311) (xy 167.583921 127.161367) (xy 167.720681 127.069987) (xy 167.836987 126.953681) + (xy 167.928367 126.816921) (xy 167.991311 126.66496) (xy 168.0234 126.50364) (xy 168.0234 126.33916) (xy 167.991311 126.17784) + (xy 167.928367 126.025879) (xy 167.836987 125.889119) (xy 167.720681 125.772813) (xy 167.583921 125.681433) (xy 167.43196 125.618489) + (xy 167.27064 125.5864) (xy 167.10616 125.5864) (xy 166.94484 125.618489) (xy 166.868765 125.65) (xy 166.088072 125.65) + (xy 166.088072 125.41) (xy 166.075812 125.285518) (xy 166.039502 125.16582) (xy 165.980537 125.055506) (xy 165.901185 124.958815) + (xy 165.804494 124.879463) (xy 165.69418 124.820498) (xy 165.574482 124.784188) (xy 165.45 124.771928) (xy 164.330748 124.771928) + (xy 164.462953 124.452756) (xy 164.545 124.040279) (xy 164.545 123.619721) (xy 164.462953 123.207244) (xy 164.302012 122.818698) + (xy 164.264985 122.763283) (xy 164.430779 122.694609) (xy 164.690379 122.52115) (xy 164.91115 122.300379) (xy 165.084609 122.040779) + (xy 165.204089 121.752327) (xy 165.265 121.446109) (xy 165.265 121.133891) (xy 165.204089 120.827673) (xy 165.084609 120.539221) + (xy 164.91115 120.279621) (xy 164.690379 120.05885) (xy 164.430779 119.885391) (xy 164.142327 119.765911) (xy 163.836109 119.705) + (xy 163.523891 119.705) (xy 163.217673 119.765911) (xy 163.123303 119.805) (xy 162.95374 119.805) (xy 162.666842 119.862068) + (xy 162.396589 119.97401) (xy 162.153368 120.136525) (xy 161.946525 120.343368) (xy 161.78401 120.586589) (xy 161.672068 120.856842) + (xy 161.615 121.14374) (xy 161.615 121.43626) (xy 161.672068 121.723158) (xy 161.707988 121.809876) (xy 161.398698 121.937988) + (xy 161.176252 122.086622) (xy 161.181817 122.073186) (xy 161.285 121.554449) (xy 161.285 121.025551) (xy 161.181817 120.506814) + (xy 160.979417 120.018175) (xy 160.750114 119.674999) (xy 170.782598 119.674999) + ) + ) + (filled_polygon + (pts + (xy 105.060498 124.26082) (xy 105.024188 124.380518) (xy 105.011928 124.505) (xy 105.015 124.71925) (xy 105.17375 124.878) + (xy 106.523 124.878) (xy 106.523 124.858) (xy 106.777 124.858) (xy 106.777 124.878) (xy 106.797 124.878) + (xy 106.797 125.132) (xy 106.777 125.132) (xy 106.777 125.152) (xy 106.523 125.152) (xy 106.523 125.132) + (xy 105.17375 125.132) (xy 105.015 125.29075) (xy 105.011928 125.505) (xy 105.024188 125.629482) (xy 105.060498 125.74918) + (xy 105.119463 125.859494) (xy 105.198815 125.956185) (xy 105.295138 126.035235) (xy 105.265099 126.107755) (xy 105.23301 126.269075) + (xy 105.23301 126.433555) (xy 105.265099 126.594875) (xy 105.308011 126.698474) (xy 105.30801 128.078378) (xy 105.306511 128.07084) + (xy 105.243567 127.918879) (xy 105.152187 127.782119) (xy 105.035881 127.665813) (xy 104.899121 127.574433) (xy 104.74716 127.511489) + (xy 104.671176 127.496375) (xy 104.283141 127.10834) (xy 104.259339 127.079337) (xy 104.143614 126.984364) (xy 104.011585 126.913792) + (xy 103.868324 126.870335) (xy 103.756671 126.859338) (xy 103.75666 126.859338) (xy 103.719338 126.855662) (xy 103.682016 126.859338) + (xy 101.607306 126.859338) (xy 101.543653 126.770509) (xy 101.452359 126.685003) (xy 101.346137 126.61895) (xy 101.22907 126.574889) + (xy 101.105657 126.554513) (xy 100.98064 126.558606) (xy 100.858824 126.587009) (xy 100.744889 126.638632) (xy 100.653371 126.69147) + (xy 100.621149 126.665026) (xy 100.48912 126.594454) (xy 100.345859 126.550997) (xy 100.234206 126.54) (xy 100.234195 126.54) + (xy 100.196873 126.536324) (xy 100.159551 126.54) (xy 99.349925 126.54) (xy 99.3126 126.536324) (xy 99.275275 126.54) + (xy 99.275267 126.54) (xy 99.219258 126.545517) (xy 99.157787 126.453519) (xy 99.041481 126.337213) (xy 98.904721 126.245833) + (xy 98.851156 126.223646) (xy 99.314803 125.76) (xy 100.827843 125.76) (xy 100.93144 125.802911) (xy 101.09276 125.835) + (xy 101.25724 125.835) (xy 101.41856 125.802911) (xy 101.570521 125.739967) (xy 101.707281 125.648587) (xy 101.823587 125.532281) + (xy 101.914967 125.395521) (xy 101.957879 125.291922) (xy 102.01373 125.236071) (xy 101.999179 125.28404) (xy 101.937089 125.43394) + (xy 101.905 125.59526) (xy 101.905 125.75974) (xy 101.937089 125.92106) (xy 102.000033 126.073021) (xy 102.091413 126.209781) + (xy 102.207719 126.326087) (xy 102.344479 126.417467) (xy 102.49644 126.480411) (xy 102.65776 126.5125) (xy 102.82224 126.5125) + (xy 102.98356 126.480411) (xy 103.135521 126.417467) (xy 103.272281 126.326087) (xy 103.388587 126.209781) (xy 103.479967 126.073021) + (xy 103.542911 125.92106) (xy 103.575 125.75974) (xy 103.575 125.699801) (xy 105.113913 124.160888) + ) + ) + (filled_polygon + (pts + (xy 190.5384 119.566442) (xy 190.495489 119.67004) (xy 190.4634 119.83136) (xy 190.4634 119.99584) (xy 190.495489 120.15716) + (xy 190.558433 120.309121) (xy 190.649813 120.445881) (xy 190.742815 120.538883) (xy 183.999771 127.281928) (xy 183.330748 127.281928) + (xy 183.462953 126.962756) (xy 183.545 126.550279) (xy 183.545 126.129721) (xy 183.462953 125.717244) (xy 183.302012 125.328698) + (xy 183.264985 125.273283) (xy 183.430779 125.204609) (xy 183.690379 125.03115) (xy 183.91115 124.810379) (xy 184.084609 124.550779) + (xy 184.204089 124.262327) (xy 184.265 123.956109) (xy 184.265 123.643891) (xy 184.204089 123.337673) (xy 184.182271 123.284999) + (xy 186.390215 123.284999) (xy 186.427537 123.288675) (xy 186.464859 123.284999) (xy 186.46487 123.284999) (xy 186.576523 123.274002) + (xy 186.719784 123.230545) (xy 186.851813 123.159973) (xy 186.967538 123.065) (xy 186.991341 123.035996) (xy 187.694265 122.333072) + (xy 188.25 122.333072) (xy 188.374482 122.320812) (xy 188.49418 122.284502) (xy 188.604494 122.225537) (xy 188.701185 122.146185) + (xy 188.780537 122.049494) (xy 188.839502 121.93918) (xy 188.875812 121.819482) (xy 188.888072 121.695) (xy 188.888072 121.139266) + (xy 189.114392 120.912946) (xy 189.217989 120.870035) (xy 189.354749 120.778655) (xy 189.471055 120.662349) (xy 189.562435 120.525589) + (xy 189.625379 120.373628) (xy 189.657468 120.212308) (xy 189.657468 120.047828) (xy 189.644001 119.980127) (xy 189.663803 119.955998) + (xy 190.160268 119.459533) (xy 190.19356 119.452911) (xy 190.345521 119.389967) (xy 190.482281 119.298587) (xy 190.538401 119.242467) + ) + ) + (filled_polygon + (pts + (xy 121.970889 118.77644) (xy 121.9388 118.93776) (xy 121.9388 119.10224) (xy 121.970889 119.26356) (xy 121.972601 119.267693) + (xy 121.9726 120.695267) (xy 121.9726 121.057332) (xy 121.972601 121.057339) (xy 121.9726 121.385442) (xy 121.929689 121.48904) + (xy 121.8976 121.65036) (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.972601 122.079759) (xy 121.9726 122.985443) + (xy 121.929689 123.08904) (xy 121.8976 123.25036) (xy 121.8976 123.41484) (xy 121.929689 123.57616) (xy 121.9726 123.679757) + (xy 121.9726 123.895278) (xy 121.968924 123.9326) (xy 121.9726 123.969922) (xy 121.9726 123.969932) (xy 121.983597 124.081585) + (xy 122.01936 124.199482) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.135493 124.403017) (xy 122.192599 124.472601) + (xy 122.221603 124.496404) (xy 122.436196 124.710997) (xy 122.459999 124.740001) (xy 122.575724 124.834974) (xy 122.707753 124.905546) + (xy 122.762007 124.922004) (xy 122.771627 124.940001) (xy 120.62351 124.940001) (xy 120.635 124.88224) (xy 120.635 124.71776) + (xy 120.602911 124.55644) (xy 120.539967 124.404479) (xy 120.448587 124.267719) (xy 120.332281 124.151413) (xy 120.195521 124.060033) + (xy 120.092926 124.017537) (xy 120.103062 124.008044) (xy 120.175921 123.906371) (xy 120.227543 123.792437) (xy 120.255948 123.67062) + (xy 120.26004 123.545603) (xy 120.239664 123.422189) (xy 120.181245 123.216035) (xy 119.986819 123.103783) (xy 120.140158 123.062696) + (xy 120.130182 123.025464) (xy 120.24356 123.002911) (xy 120.395521 122.939967) (xy 120.532281 122.848587) (xy 120.648587 122.732281) + (xy 120.739967 122.595521) (xy 120.802911 122.44356) (xy 120.835 122.28224) (xy 120.835 122.11776) (xy 120.802911 121.95644) + (xy 120.739967 121.804479) (xy 120.648587 121.667719) (xy 120.532281 121.551413) (xy 120.395521 121.460033) (xy 120.24356 121.397089) + (xy 120.08224 121.365) (xy 119.91776 121.365) (xy 119.75644 121.397089) (xy 119.702974 121.419235) (xy 119.527912 120.765894) + (xy 119.483851 120.648827) (xy 119.417799 120.542605) (xy 119.332292 120.451311) (xy 119.230618 120.378453) (xy 119.116684 120.326829) + (xy 118.994867 120.298426) (xy 118.86985 120.294333) (xy 118.746437 120.314709) (xy 118.085658 120.491764) (xy 118.027859 120.276054) + (xy 118.022151 120.241484) (xy 118.009809 120.208692) (xy 118.009807 120.208684) (xy 117.972887 120.11059) (xy 117.899032 119.991823) + (xy 117.803427 119.889746) (xy 117.689744 119.808281) (xy 117.562352 119.750561) (xy 117.426149 119.718803) (xy 117.286366 119.714227) + (xy 117.286365 119.714227) (xy 117.182953 119.7313) (xy 117.182948 119.731301) (xy 117.148377 119.737009) (xy 117.115583 119.749352) + (xy 116.935 119.797739) (xy 116.935 119.71776) (xy 116.902911 119.55644) (xy 116.86 119.452843) (xy 116.86 119.214802) + (xy 117.213799 118.861004) (xy 117.213808 118.860993) (xy 117.439809 118.634992) (xy 122.029478 118.634992) + ) + ) + (filled_polygon + (pts + (xy 130.529667 121.6642) (xy 130.529676 121.6642) (xy 130.566999 121.667876) (xy 130.604322 121.6642) (xy 137.738636 121.6642) + (xy 137.414424 121.988412) (xy 137.120583 122.428175) (xy 136.918183 122.916814) (xy 136.815 123.435551) (xy 136.815 123.964449) + (xy 136.918183 124.483186) (xy 136.923749 124.496623) (xy 136.701302 124.347989) (xy 136.392012 124.219877) (xy 136.427932 124.133158) + (xy 136.485 123.84626) (xy 136.485 123.55374) (xy 136.427932 123.266842) (xy 136.31599 122.996589) (xy 136.153475 122.753368) + (xy 135.946632 122.546525) (xy 135.703411 122.38401) (xy 135.433158 122.272068) (xy 135.14626 122.215) (xy 134.976697 122.215) + (xy 134.882327 122.175911) (xy 134.576109 122.115) (xy 134.263891 122.115) (xy 133.957673 122.175911) (xy 133.669221 122.295391) + (xy 133.409621 122.46885) (xy 133.18885 122.689621) (xy 133.015391 122.949221) (xy 132.895911 123.237673) (xy 132.835 123.543891) + (xy 132.835 123.856109) (xy 132.895911 124.162327) (xy 133.015391 124.450779) (xy 133.143113 124.641928) (xy 131.391729 124.641928) + (xy 130.438804 123.689003) (xy 130.415001 123.659999) (xy 130.299276 123.565026) (xy 130.167247 123.494454) (xy 130.023986 123.450997) + (xy 129.912333 123.44) (xy 129.912322 123.44) (xy 129.875 123.436324) (xy 129.837678 123.44) (xy 129.347157 123.44) + (xy 129.24356 123.397089) (xy 129.08224 123.365) (xy 128.91776 123.365) (xy 128.75644 123.397089) (xy 128.746866 123.401055) + (xy 128.730537 123.370506) (xy 128.651185 123.273815) (xy 128.554494 123.194463) (xy 128.44418 123.135498) (xy 128.324482 123.099188) + (xy 128.2 123.086928) (xy 126.96 123.086928) (xy 126.96 122.713072) (xy 128.2 122.713072) (xy 128.324482 122.700812) + (xy 128.44418 122.664502) (xy 128.554494 122.605537) (xy 128.651185 122.526185) (xy 128.730537 122.429494) (xy 128.767683 122.36) + (xy 128.966799 122.36) (xy 128.996721 122.389922) (xy 129.039633 122.493521) (xy 129.131013 122.630281) (xy 129.247319 122.746587) + (xy 129.384079 122.837967) (xy 129.53604 122.900911) (xy 129.69736 122.933) (xy 129.86184 122.933) (xy 130.02316 122.900911) + (xy 130.175121 122.837967) (xy 130.311881 122.746587) (xy 130.428187 122.630281) (xy 130.519567 122.493521) (xy 130.582511 122.34156) + (xy 130.6146 122.18024) (xy 130.6146 122.01576) (xy 130.582511 121.85444) (xy 130.519567 121.702479) (xy 130.491476 121.660439) + ) + ) + (filled_polygon + (pts + (xy 118.810987 123.155884) (xy 118.830305 123.150708) (xy 118.896046 123.396054) (xy 118.876727 123.40123) (xy 118.881903 123.420548) + (xy 118.871193 123.423418) (xy 118.7951 123.139435) (xy 118.805811 123.136565) + ) + ) + (filled_polygon + (pts + (xy 190.787398 118.39819) (xy 190.7584 118.421988) (xy 190.756471 118.424338) (xy 190.752911 118.40644) (xy 190.689967 118.254479) + (xy 190.598587 118.117719) (xy 190.482281 118.001413) (xy 190.345521 117.910033) (xy 190.19356 117.847089) (xy 190.03224 117.815) + (xy 189.86776 117.815) (xy 189.70644 117.847089) (xy 189.554479 117.910033) (xy 189.417719 118.001413) (xy 189.301413 118.117719) + (xy 189.210033 118.254479) (xy 189.206012 118.264186) (xy 188.815076 118.655123) (xy 188.780537 118.590506) (xy 188.701185 118.493815) + (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) (xy 188.25 118.306928) (xy 186.25 118.306928) + (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) (xy 185.798815 118.493815) (xy 185.719463 118.590506) + (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) (xy 185.611928 119.945) (xy 185.624188 120.069482) + (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) (xy 185.719463 120.340506) (xy 185.660498 120.45082) + (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.695) (xy 185.618822 121.764999) (xy 184.481178 121.764999) + (xy 184.488072 121.695) (xy 184.485 121.48075) (xy 184.32625 121.322) (xy 182.977 121.322) (xy 182.977 121.342) + (xy 182.723 121.342) (xy 182.723 121.322) (xy 181.37375 121.322) (xy 181.215 121.48075) (xy 181.211928 121.695) + (xy 181.218822 121.764999) (xy 180.154804 121.764999) (xy 179.592903 121.2031) (xy 179.62182 121.194328) (xy 179.745163 121.1284) + (xy 179.853275 121.039675) (xy 179.942 120.931563) (xy 180.007928 120.80822) (xy 180.048527 120.674384) (xy 180.0588 120.570077) + (xy 180.0588 120.570076) (xy 180.062235 120.5352) (xy 180.0588 120.500323) (xy 180.0588 120.31) (xy 180.127002 120.31) + (xy 180.127002 120.151252) (xy 180.278 120.30225) (xy 180.278 120.32604) (xy 180.310089 120.48736) (xy 180.373033 120.639321) + (xy 180.464413 120.776081) (xy 180.580719 120.892387) (xy 180.717479 120.983767) (xy 180.86944 121.046711) (xy 181.03076 121.0788) + (xy 181.19524 121.0788) (xy 181.353141 121.047391) (xy 181.37375 121.068) (xy 182.723 121.068) (xy 182.723 121.048) + (xy 182.977 121.048) (xy 182.977 121.068) (xy 184.32625 121.068) (xy 184.485 120.90925) (xy 184.488072 120.695) + (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) (xy 184.363708 120.32) (xy 184.380537 120.299494) + (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) (xy 184.488072 118.945) (xy 184.475812 118.820518) + (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) (xy 184.379711 118.35376) + (xy 184.403516 118.234088) (xy 185.418404 117.2192) (xy 191.966387 117.2192) + ) + ) + (filled_polygon + (pts + (xy 111.711928 91.68) (xy 111.724188 91.804482) (xy 111.760498 91.92418) (xy 111.819463 92.034494) (xy 111.898815 92.131185) + (xy 111.995506 92.210537) (xy 112.10582 92.269502) (xy 112.225518 92.305812) (xy 112.266392 92.309838) (xy 112.247089 92.35644) + (xy 112.215 92.51776) (xy 112.215 92.68224) (xy 112.247089 92.84356) (xy 112.310033 92.995521) (xy 112.401413 93.132281) + (xy 112.517719 93.248587) (xy 112.654479 93.339967) (xy 112.80644 93.402911) (xy 112.96776 93.435) (xy 113.13224 93.435) + (xy 113.29356 93.402911) (xy 113.445521 93.339967) (xy 113.582281 93.248587) (xy 113.698587 93.132281) (xy 113.789967 92.995521) + (xy 113.852911 92.84356) (xy 113.885 92.68224) (xy 113.885 92.51776) (xy 113.852911 92.35644) (xy 113.837019 92.318072) + (xy 114.65 92.318072) (xy 114.774482 92.305812) (xy 114.89418 92.269502) (xy 115.004494 92.210537) (xy 115.101185 92.131185) + (xy 115.128525 92.097872) (xy 115.329017 92.298364) (xy 115.678698 92.532013) (xy 115.894302 92.621319) (xy 115.825 92.969721) + (xy 115.825 93.390279) (xy 115.907047 93.802756) (xy 116.067988 94.191302) (xy 116.301637 94.540983) (xy 116.599017 94.838363) + (xy 116.948698 95.072012) (xy 117.337244 95.232953) (xy 117.749721 95.315) (xy 117.810196 95.315) (xy 115.249503 97.875694) + (xy 115.220499 97.899497) (xy 115.175558 97.954258) (xy 115.125526 98.015222) (xy 115.078139 98.103876) (xy 115.054954 98.147252) + (xy 115.011497 98.290513) (xy 115.0005 98.402166) (xy 115.0005 98.402176) (xy 114.996824 98.439498) (xy 115.0005 98.476821) + (xy 115.000501 104.022767) (xy 114.996824 104.060099) (xy 115.000501 104.097432) (xy 115.011498 104.209085) (xy 115.02017 104.237673) + (xy 115.054954 104.352345) (xy 115.125526 104.484375) (xy 115.195319 104.569417) (xy 115.2205 104.6001) (xy 115.249498 104.623898) + (xy 116.264023 105.638425) (xy 116.14626 105.615) (xy 115.976697 105.615) (xy 115.882327 105.575911) (xy 115.576109 105.515) + (xy 115.263891 105.515) (xy 114.957673 105.575911) (xy 114.669221 105.695391) (xy 114.409621 105.86885) (xy 114.18885 106.089621) + (xy 114.015391 106.349221) (xy 113.895911 106.637673) (xy 113.835 106.943891) (xy 113.835 107.256109) (xy 113.895911 107.562327) + (xy 114.015391 107.850779) (xy 114.143113 108.041928) (xy 112.35 108.041928) (xy 112.225518 108.054188) (xy 112.10582 108.090498) + (xy 111.995506 108.149463) (xy 111.898815 108.228815) (xy 111.819463 108.325506) (xy 111.760498 108.43582) (xy 111.724188 108.555518) + (xy 111.711928 108.68) (xy 111.711928 110.68) (xy 111.724188 110.804482) (xy 111.760498 110.92418) (xy 111.819463 111.034494) + (xy 111.898815 111.131185) (xy 111.995506 111.210537) (xy 111.9962 111.210908) (xy 111.965 111.36776) (xy 111.965 111.441408) + (xy 111.83224 111.415) (xy 111.66776 111.415) (xy 111.50644 111.447089) (xy 111.354479 111.510033) (xy 111.217719 111.601413) + (xy 111.101413 111.717719) (xy 111.010033 111.854479) (xy 110.947089 112.00644) (xy 110.915 112.16776) (xy 110.915 112.33224) + (xy 110.947089 112.49356) (xy 111.010033 112.645521) (xy 111.101413 112.782281) (xy 111.217719 112.898587) (xy 111.354479 112.989967) + (xy 111.458078 113.032879) (xy 112.686201 114.261003) (xy 112.709999 114.290001) (xy 112.825724 114.384974) (xy 112.957753 114.455546) + (xy 113.101014 114.499003) (xy 113.212667 114.51) (xy 113.212676 114.51) (xy 113.249999 114.513676) (xy 113.287322 114.51) + (xy 113.902843 114.51) (xy 114.00644 114.552911) (xy 114.16776 114.585) (xy 114.33224 114.585) (xy 114.49356 114.552911) + (xy 114.645521 114.489967) (xy 114.782281 114.398587) (xy 114.898587 114.282281) (xy 114.989967 114.145521) (xy 115.052911 113.99356) + (xy 115.085 113.83224) (xy 115.085 113.66776) (xy 115.052911 113.50644) (xy 114.989967 113.354479) (xy 114.898587 113.217719) + (xy 114.782281 113.101413) (xy 114.645521 113.010033) (xy 114.49356 112.947089) (xy 114.33224 112.915) (xy 114.16776 112.915) + (xy 114.00644 112.947089) (xy 113.902843 112.99) (xy 113.564802 112.99) (xy 112.859801 112.285) (xy 112.88224 112.285) + (xy 113.04356 112.252911) (xy 113.195521 112.189967) (xy 113.332281 112.098587) (xy 113.448587 111.982281) (xy 113.539967 111.845521) + (xy 113.602911 111.69356) (xy 113.635 111.53224) (xy 113.635 111.36776) (xy 113.625116 111.318072) (xy 114.65 111.318072) + (xy 114.774482 111.305812) (xy 114.89418 111.269502) (xy 115.004494 111.210537) (xy 115.101185 111.131185) (xy 115.128525 111.097872) + (xy 115.329017 111.298364) (xy 115.678698 111.532013) (xy 115.894302 111.621319) (xy 115.825 111.969721) (xy 115.825 112.390279) + (xy 115.907047 112.802756) (xy 116.067988 113.191302) (xy 116.301637 113.540983) (xy 116.599017 113.838363) (xy 116.948698 114.072012) + (xy 117.188619 114.171391) (xy 117.105023 114.239996) (xy 117.081225 114.268994) (xy 112.608078 118.742142) (xy 112.504479 118.785054) + (xy 112.367719 118.876434) (xy 112.251413 118.99274) (xy 112.160033 119.1295) (xy 112.097089 119.281461) (xy 112.065 119.442781) + (xy 112.065 119.511728) (xy 111.5498 119.511728) (xy 111.425318 119.523988) (xy 111.30562 119.560298) (xy 111.195306 119.619263) + (xy 111.098615 119.698615) (xy 111.019263 119.795306) (xy 110.960298 119.90562) (xy 110.923988 120.025318) (xy 110.911728 120.1498) + (xy 110.911728 120.233468) (xy 110.693076 120.45212) (xy 110.639978 120.474114) (xy 110.630994 120.474999) (xy 110.630985 120.474999) + (xy 110.519332 120.485996) (xy 110.376071 120.529453) (xy 110.244042 120.600025) (xy 110.128317 120.694998) (xy 110.104519 120.723996) + (xy 109.937872 120.890643) (xy 109.937872 120.482188) (xy 110.044581 120.410887) (xy 110.160887 120.294581) (xy 110.252267 120.157821) + (xy 110.295178 120.054224) (xy 110.511003 119.838399) (xy 110.540001 119.814601) (xy 110.581828 119.763635) (xy 110.634974 119.698877) + (xy 110.705546 119.566847) (xy 110.718001 119.525788) (xy 110.749003 119.423586) (xy 110.76 119.311933) (xy 110.76 119.311924) + (xy 110.763676 119.274601) (xy 110.76 119.237278) (xy 110.76 102.037323) (xy 110.763676 102) (xy 110.76 101.962677) + (xy 110.76 101.962667) (xy 110.749003 101.851014) (xy 110.705546 101.707753) (xy 110.634974 101.575724) (xy 110.540001 101.459999) + (xy 110.511004 101.436202) (xy 109.399802 100.325) (xy 110.886928 100.325) (xy 110.886928 101.625) (xy 110.899188 101.749482) + (xy 110.935498 101.86918) (xy 110.994463 101.979494) (xy 111.073815 102.076185) (xy 111.167863 102.153368) (xy 111.165 102.16776) + (xy 111.165 102.33224) (xy 111.197089 102.49356) (xy 111.260033 102.645521) (xy 111.329844 102.75) (xy 111.260033 102.854479) + (xy 111.197089 103.00644) (xy 111.165 103.16776) (xy 111.165 103.33224) (xy 111.167863 103.346632) (xy 111.073815 103.423815) + (xy 110.994463 103.520506) (xy 110.935498 103.63082) (xy 110.899188 103.750518) (xy 110.886928 103.875) (xy 110.886928 105.175) + (xy 110.899188 105.299482) (xy 110.935498 105.41918) (xy 110.994463 105.529494) (xy 111.073815 105.626185) (xy 111.170506 105.705537) + (xy 111.28082 105.764502) (xy 111.400518 105.800812) (xy 111.525 105.813072) (xy 112.475 105.813072) (xy 112.599482 105.800812) + (xy 112.71918 105.764502) (xy 112.829494 105.705537) (xy 112.926185 105.626185) (xy 113.005537 105.529494) (xy 113.064502 105.41918) + (xy 113.100812 105.299482) (xy 113.113072 105.175) (xy 113.113072 103.875) (xy 113.100812 103.750518) (xy 113.064502 103.63082) + (xy 113.005537 103.520506) (xy 112.926185 103.423815) (xy 112.832137 103.346632) (xy 112.835 103.33224) (xy 112.835 103.16776) + (xy 112.802911 103.00644) (xy 112.739967 102.854479) (xy 112.670156 102.75) (xy 112.739967 102.645521) (xy 112.802911 102.49356) + (xy 112.835 102.33224) (xy 112.835 102.16776) (xy 112.832137 102.153368) (xy 112.926185 102.076185) (xy 113.005537 101.979494) + (xy 113.064502 101.86918) (xy 113.100812 101.749482) (xy 113.113072 101.625) (xy 113.113072 100.325) (xy 113.100812 100.200518) + (xy 113.064502 100.08082) (xy 113.005537 99.970506) (xy 112.926185 99.873815) (xy 112.829494 99.794463) (xy 112.71918 99.735498) + (xy 112.599482 99.699188) (xy 112.475 99.686928) (xy 111.525 99.686928) (xy 111.400518 99.699188) (xy 111.28082 99.735498) + (xy 111.170506 99.794463) (xy 111.073815 99.873815) (xy 110.994463 99.970506) (xy 110.935498 100.08082) (xy 110.899188 100.200518) + (xy 110.886928 100.325) (xy 109.399802 100.325) (xy 107.682825 98.608024) (xy 107.69276 98.61) (xy 107.85724 98.61) + (xy 108.01856 98.577911) (xy 108.170521 98.514967) (xy 108.307281 98.423587) (xy 108.423587 98.307281) (xy 108.514967 98.170521) + (xy 108.538763 98.113072) (xy 109.425 98.113072) (xy 109.549482 98.100812) (xy 109.66918 98.064502) (xy 109.779494 98.005537) + (xy 109.876185 97.926185) (xy 109.955537 97.829494) (xy 110.014502 97.71918) (xy 110.033093 97.657894) (xy 110.638835 98.263637) + (xy 110.701414 98.357293) (xy 110.81772 98.473599) (xy 110.95448 98.564979) (xy 111.106441 98.627923) (xy 111.267761 98.660012) + (xy 111.432241 98.660012) (xy 111.593561 98.627923) (xy 111.745522 98.564979) (xy 111.882282 98.473599) (xy 111.998588 98.357293) + (xy 112.089968 98.220533) (xy 112.152912 98.068572) (xy 112.185001 97.907252) (xy 112.185001 97.742772) (xy 112.152912 97.581452) + (xy 112.089968 97.429491) (xy 111.998588 97.292731) (xy 111.882282 97.176425) (xy 111.745522 97.085045) (xy 111.593561 97.022101) + (xy 111.535317 97.010515) (xy 111.01 96.485199) (xy 111.01 90.554616) (xy 111.01857 90.552911) (xy 111.170531 90.489967) + (xy 111.307291 90.398587) (xy 111.423597 90.282281) (xy 111.514977 90.145521) (xy 111.561375 90.033506) (xy 111.609983 89.974277) + (xy 111.680555 89.842248) (xy 111.711928 89.738823) + ) + ) + (filled_polygon + (pts + (xy 165.658073 112.848531) (xy 165.554475 112.891443) (xy 165.417715 112.982823) (xy 165.301409 113.099129) (xy 165.210029 113.235889) + (xy 165.147085 113.38785) (xy 165.114996 113.54917) (xy 165.114996 113.71365) (xy 165.147085 113.87497) (xy 165.210029 114.026931) + (xy 165.301409 114.163691) (xy 165.417715 114.279997) (xy 165.554475 114.371377) (xy 165.706436 114.434321) (xy 165.867756 114.46641) + (xy 166.032236 114.46641) (xy 166.193556 114.434321) (xy 166.345517 114.371377) (xy 166.482277 114.279997) (xy 166.598583 114.163691) + (xy 166.689963 114.026931) (xy 166.732875 113.923333) (xy 167.482103 113.174104) (xy 171.998922 117.690924) (xy 172.041833 117.794521) + (xy 172.133213 117.931281) (xy 172.249519 118.047587) (xy 172.386279 118.138967) (xy 172.53824 118.201911) (xy 172.69956 118.234) + (xy 172.86404 118.234) (xy 172.9882 118.209303) (xy 172.9882 118.37024) (xy 173.020289 118.53156) (xy 173.083233 118.683521) + (xy 173.174613 118.820281) (xy 173.290919 118.936587) (xy 173.427679 119.027967) (xy 173.57964 119.090911) (xy 173.74096 119.123) + (xy 173.761928 119.123) (xy 173.761928 119.675) (xy 173.774188 119.799482) (xy 173.810498 119.91918) (xy 173.869463 120.029494) + (xy 173.948815 120.126185) (xy 174.045506 120.205537) (xy 174.15582 120.264502) (xy 174.275518 120.300812) (xy 174.4 120.313072) + (xy 175.1388 120.313072) (xy 175.1388 120.500323) (xy 175.135365 120.5352) (xy 175.144387 120.6268) (xy 173.884003 120.6268) + (xy 171.661203 118.404002) (xy 171.6374 118.374998) (xy 171.521675 118.280025) (xy 171.389646 118.209453) (xy 171.246385 118.165996) + (xy 171.134732 118.154999) (xy 171.134721 118.154999) (xy 171.097399 118.151323) (xy 171.060077 118.154999) (xy 161.052135 118.154999) + (xy 161.063835 118.0362) (xy 161.0604 118.001323) (xy 161.0604 117.8) (xy 161.127002 117.8) (xy 161.127002 117.641252) + (xy 161.28575 117.8) (xy 161.8 117.803072) (xy 161.924482 117.790812) (xy 162.04418 117.754502) (xy 162.154494 117.695537) + (xy 162.251185 117.616185) (xy 162.330537 117.519494) (xy 162.389502 117.40918) (xy 162.425812 117.289482) (xy 162.438072 117.165) + (xy 162.435 116.95075) (xy 162.27625 116.792) (xy 161.127 116.792) (xy 161.127 116.812) (xy 161.0604 116.812) + (xy 161.0604 116.518) (xy 161.127 116.518) (xy 161.127 116.538) (xy 162.27625 116.538) (xy 162.435 116.37925) + (xy 162.438072 116.165) (xy 162.425812 116.040518) (xy 162.389502 115.92082) (xy 162.330537 115.810506) (xy 162.313708 115.79) + (xy 162.330537 115.769494) (xy 162.389502 115.65918) (xy 162.425812 115.539482) (xy 162.427882 115.518463) (xy 162.505211 115.455001) + (xy 162.529013 115.425998) (xy 162.785512 115.169499) (xy 162.88911 115.126588) (xy 163.02587 115.035208) (xy 163.142176 114.918902) + (xy 163.233556 114.782142) (xy 163.2965 114.630181) (xy 163.328589 114.468861) (xy 163.328589 114.304381) (xy 163.2965 114.143061) + (xy 163.233556 113.9911) (xy 163.142176 113.85434) (xy 163.02587 113.738034) (xy 162.88911 113.646654) (xy 162.737149 113.58371) + (xy 162.575829 113.551621) (xy 162.411349 113.551621) (xy 162.250029 113.58371) (xy 162.098068 113.646654) (xy 161.961308 113.738034) + (xy 161.911439 113.787903) (xy 161.8 113.776928) (xy 161.76 113.776928) (xy 161.76 113.223722) (xy 161.763676 113.186399) + (xy 161.76 113.149076) (xy 161.76 113.149067) (xy 161.749003 113.037414) (xy 161.705546 112.894153) (xy 161.634974 112.762124) + (xy 161.625032 112.75001) (xy 165.756595 112.75001) + ) + ) + (filled_polygon + (pts + (xy 143.35451 118.795112) (xy 143.383513 118.818914) (xy 144.708799 120.1442) (xy 142.982162 120.1442) (xy 143.054494 120.105537) + (xy 143.151185 120.026185) (xy 143.230537 119.929494) (xy 143.289502 119.81918) (xy 143.325812 119.699482) (xy 143.338072 119.575) + (xy 143.335 119.36075) (xy 143.17625 119.202) (xy 142.027 119.202) (xy 142.027 119.222) (xy 141.9604 119.222) + (xy 141.9604 118.928) (xy 142.027 118.928) (xy 142.027 118.948) (xy 143.17625 118.948) (xy 143.335 118.78925) + (xy 143.335252 118.771647) + ) + ) + (filled_polygon + (pts + (xy 129.628319 116.066387) (xy 129.765079 116.157767) (xy 129.91704 116.220711) (xy 130.07836 116.2528) (xy 130.24284 116.2528) + (xy 130.40416 116.220711) (xy 130.507757 116.1778) (xy 132.493799 116.1778) (xy 134.336599 118.020601) (xy 134.336599 118.137941) + (xy 134.332923 118.175263) (xy 134.336599 118.212585) (xy 134.336599 118.212596) (xy 134.347596 118.324249) (xy 134.391053 118.46751) + (xy 134.461625 118.599539) (xy 134.556599 118.715264) (xy 134.585597 118.739062) (xy 134.88659 119.040055) (xy 134.929501 119.143653) + (xy 135.020881 119.280413) (xy 135.137187 119.396719) (xy 135.273947 119.488099) (xy 135.425908 119.551043) (xy 135.587228 119.583132) + (xy 135.662729 119.583132) (xy 135.674188 119.699482) (xy 135.710498 119.81918) (xy 135.769463 119.929494) (xy 135.848815 120.026185) + (xy 135.945506 120.105537) (xy 136.017838 120.1442) (xy 130.881802 120.1442) (xy 129.465679 118.728078) (xy 129.422767 118.624479) + (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) (xy 128.92636 118.217089) (xy 128.76504 118.185) + (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) (xy 128.47418 117.955498) (xy 128.354482 117.919188) + (xy 128.23 117.906928) (xy 127.696267 117.906928) (xy 129.582564 116.020632) + ) + ) + (filled_polygon + (pts + (xy 150.544189 115.771742) (xy 150.462011 115.925488) (xy 150.428813 116.034924) (xy 150.417814 116.071185) (xy 150.411405 116.092311) + (xy 150.3986 116.222324) (xy 150.3986 116.222331) (xy 150.395922 116.249528) (xy 150.2836 116.249528) (xy 150.159118 116.261788) + (xy 150.03942 116.298098) (xy 149.929106 116.357063) (xy 149.832415 116.436415) (xy 149.753063 116.533106) (xy 149.694098 116.64342) + (xy 149.657788 116.763118) (xy 149.645528 116.8876) (xy 149.645528 117.8876) (xy 149.657788 118.012082) (xy 149.694098 118.13178) + (xy 149.753063 118.242094) (xy 149.769892 118.2626) (xy 149.753063 118.283106) (xy 149.694098 118.39342) (xy 149.690256 118.406086) + (xy 149.630287 118.424277) (xy 149.604649 118.432054) (xy 149.472619 118.502626) (xy 149.426258 118.540674) (xy 149.356895 118.597599) + (xy 149.333097 118.626597) (xy 148.518851 119.440844) (xy 148.5186 119.42335) (xy 148.35985 119.2646) (xy 147.0106 119.2646) + (xy 147.0106 119.2846) (xy 146.7566 119.2846) (xy 146.7566 119.2646) (xy 146.7366 119.2646) (xy 146.7366 119.0106) + (xy 146.7566 119.0106) (xy 146.7566 118.9906) (xy 147.0106 118.9906) (xy 147.0106 119.0106) (xy 148.35985 119.0106) + (xy 148.5186 118.85185) (xy 148.521672 118.6376) (xy 148.509412 118.513118) (xy 148.473102 118.39342) (xy 148.414137 118.283106) + (xy 148.397308 118.2626) (xy 148.414137 118.242094) (xy 148.473102 118.13178) (xy 148.509412 118.012082) (xy 148.521672 117.8876) + (xy 148.521672 116.8876) (xy 148.509412 116.763118) (xy 148.473102 116.64342) (xy 148.414137 116.533106) (xy 148.334785 116.436415) + (xy 148.238094 116.357063) (xy 148.12778 116.298098) (xy 148.008082 116.261788) (xy 147.8836 116.249528) (xy 145.8836 116.249528) + (xy 145.759118 116.261788) (xy 145.63942 116.298098) (xy 145.529106 116.357063) (xy 145.432415 116.436415) (xy 145.353063 116.533106) + (xy 145.294098 116.64342) (xy 145.291137 116.653181) (xy 145.195953 116.682054) (xy 145.063924 116.752626) (xy 144.948199 116.847599) + (xy 144.924396 116.876603) (xy 144.711798 117.089201) (xy 144.6828 117.112999) (xy 144.659002 117.141997) (xy 144.659001 117.141998) + (xy 144.587826 117.228724) (xy 144.549742 117.299974) (xy 144.517254 117.360753) (xy 144.500825 117.414913) (xy 144.434512 117.33411) + (xy 144.405509 117.310308) (xy 144.253079 117.157878) (xy 144.210167 117.054279) (xy 144.118787 116.917519) (xy 144.002481 116.801213) + (xy 143.865721 116.709833) (xy 143.71376 116.646889) (xy 143.55244 116.6148) (xy 143.38796 116.6148) (xy 143.304826 116.631337) + (xy 143.289502 116.58082) (xy 143.230537 116.470506) (xy 143.151185 116.373815) (xy 143.054494 116.294463) (xy 142.94418 116.235498) + (xy 142.824482 116.199188) (xy 142.7 116.186928) (xy 141.9604 116.186928) (xy 141.9604 115.984077) (xy 141.963835 115.9492) + (xy 141.950127 115.810016) (xy 141.938413 115.7714) (xy 150.444778 115.7714) (xy 150.4821 115.775076) (xy 150.519422 115.7714) + (xy 150.519433 115.7714) (xy 150.546671 115.768717) + ) + ) + (filled_polygon + (pts + (xy 180.127 119.048) (xy 180.147 119.048) (xy 180.147 119.302) (xy 180.127 119.302) (xy 180.127 119.322) + (xy 180.0588 119.322) (xy 180.0588 119.028) (xy 180.127 119.028) + ) + ) + (filled_polygon + (pts + (xy 187.386928 109.175) (xy 187.399188 109.299482) (xy 187.435498 109.41918) (xy 187.494463 109.529494) (xy 187.573815 109.626185) + (xy 187.670506 109.705537) (xy 187.740001 109.742683) (xy 187.740001 110.842668) (xy 187.736324 110.88) (xy 187.740001 110.917333) + (xy 187.747436 110.992815) (xy 187.750998 111.028985) (xy 187.794454 111.172246) (xy 187.865026 111.304276) (xy 187.911928 111.361426) + (xy 187.911928 113.08) (xy 187.924188 113.204482) (xy 187.960498 113.32418) (xy 188.019463 113.434494) (xy 188.098815 113.531185) + (xy 188.195506 113.610537) (xy 188.1962 113.610908) (xy 188.165 113.76776) (xy 188.165 113.93224) (xy 188.197089 114.09356) + (xy 188.260033 114.245521) (xy 188.351413 114.382281) (xy 188.467719 114.498587) (xy 188.604479 114.589967) (xy 188.75644 114.652911) + (xy 188.91776 114.685) (xy 189.08224 114.685) (xy 189.24356 114.652911) (xy 189.395521 114.589967) (xy 189.532281 114.498587) + (xy 189.648587 114.382281) (xy 189.739967 114.245521) (xy 189.802911 114.09356) (xy 189.835 113.93224) (xy 189.835 113.76776) + (xy 189.825116 113.718072) (xy 190.85 113.718072) (xy 190.974482 113.705812) (xy 191.09418 113.669502) (xy 191.204494 113.610537) + (xy 191.301185 113.531185) (xy 191.328525 113.497872) (xy 191.529017 113.698364) (xy 191.878698 113.932013) (xy 192.094302 114.021319) + (xy 192.025 114.369721) (xy 192.025 114.790279) (xy 192.107047 115.202756) (xy 192.267988 115.591302) (xy 192.340083 115.6992) + (xy 185.140924 115.6992) (xy 185.103601 115.695524) (xy 185.066278 115.6992) (xy 185.066269 115.6992) (xy 184.954616 115.710197) + (xy 184.818894 115.751367) (xy 184.811355 115.753654) (xy 184.679325 115.824226) (xy 184.595685 115.892868) (xy 184.563601 115.919199) + (xy 184.539803 115.948197) (xy 183.61 116.878001) (xy 183.61 116.445521) (xy 183.613676 116.408198) (xy 183.61 116.370875) + (xy 183.61 116.370865) (xy 183.599003 116.259212) (xy 183.555546 116.115951) (xy 183.54291 116.092311) (xy 183.484974 115.983921) + (xy 183.413799 115.897195) (xy 183.390001 115.868197) (xy 183.361003 115.844399) (xy 182.223203 114.7066) (xy 183.683 113.246804) + (xy 183.683004 113.246799) (xy 184.036768 112.893036) (xy 184.101251 112.957519) (xy 184.238011 113.048899) (xy 184.389972 113.111843) + (xy 184.551292 113.143932) (xy 184.715772 113.143932) (xy 184.877092 113.111843) (xy 185.029053 113.048899) (xy 185.165813 112.957519) + (xy 185.282119 112.841213) (xy 185.373499 112.704453) (xy 185.416411 112.600855) (xy 186.411131 111.606136) (xy 186.41114 111.606125) + (xy 186.461007 111.556258) (xy 186.490011 111.532455) (xy 186.584984 111.41673) (xy 186.655556 111.284701) (xy 186.699013 111.14144) + (xy 186.71001 111.029787) (xy 186.713687 110.992454) (xy 186.71001 110.955121) (xy 186.71001 109.679789) (xy 187.386928 109.002871) + ) + ) + (filled_polygon + (pts + (xy 140.505154 115.2392) (xy 137.785277 115.2392) (xy 137.7504 115.235765) (xy 137.715523 115.2392) (xy 137.611216 115.249473) + (xy 137.47738 115.290072) (xy 137.354037 115.356) (xy 137.245925 115.444725) (xy 137.1572 115.552837) (xy 137.091272 115.67618) + (xy 137.050673 115.810016) (xy 137.036965 115.9492) (xy 137.040401 115.984087) (xy 137.040401 116.186928) (xy 136.3 116.186928) + (xy 136.175518 116.199188) (xy 136.05582 116.235498) (xy 135.945506 116.294463) (xy 135.848815 116.373815) (xy 135.769463 116.470506) + (xy 135.718954 116.565) (xy 135.51472 116.565) (xy 135.477397 116.561324) (xy 135.440074 116.565) (xy 135.440065 116.565) + (xy 135.328412 116.575997) (xy 135.185151 116.619454) (xy 135.119922 116.65432) (xy 134.1184 115.652799) (xy 135.499679 115.652799) + (xy 135.537001 115.656475) (xy 135.574323 115.652799) (xy 135.574334 115.652799) (xy 135.685987 115.641802) (xy 135.829248 115.598345) + (xy 135.961277 115.527773) (xy 136.077002 115.4328) (xy 136.100804 115.403797) (xy 136.292001 115.2126) (xy 140.499863 115.2126) + ) + ) + (filled_polygon + (pts + (xy 179.275 107.029721) (xy 179.275 107.450279) (xy 179.344302 107.798682) (xy 179.128698 107.887988) (xy 178.779017 108.121637) + (xy 178.481637 108.419017) (xy 178.247988 108.768698) (xy 178.087047 109.157244) (xy 178.005 109.569721) (xy 178.005 109.990279) + (xy 178.087047 110.402756) (xy 178.247988 110.791302) (xy 178.481637 111.140983) (xy 178.779017 111.438363) (xy 179.128698 111.672012) + (xy 179.517244 111.832953) (xy 179.929721 111.915) (xy 180.350279 111.915) (xy 180.762756 111.832953) (xy 181.151302 111.672012) + (xy 181.265104 111.595972) (xy 181.34648 111.677348) (xy 181.48324 111.768728) (xy 181.635201 111.831672) (xy 181.796521 111.863761) + (xy 181.961001 111.863761) (xy 182.122321 111.831672) (xy 182.274282 111.768728) (xy 182.277831 111.766356) (xy 182.383486 111.734307) + (xy 182.515515 111.663735) (xy 182.63124 111.568762) (xy 182.655043 111.539758) (xy 182.736729 111.458072) (xy 183.322129 111.458072) + (xy 182.608203 112.171998) (xy 182.608198 112.172002) (xy 180.833601 113.9466) (xy 176.364325 113.9466) (xy 176.327 113.942924) + (xy 176.289675 113.9466) (xy 176.289667 113.9466) (xy 176.178014 113.957597) (xy 176.034753 114.001054) (xy 175.902724 114.071626) + (xy 175.786999 114.166599) (xy 175.763201 114.195597) (xy 174.908077 115.050721) (xy 174.804479 115.093633) (xy 174.667719 115.185013) + (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) (xy 174.365 115.75136) (xy 174.365 115.91584) + (xy 174.397089 116.07716) (xy 174.460033 116.229121) (xy 174.498658 116.286928) (xy 174.4 116.286928) (xy 174.275518 116.299188) + (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.869463 116.570506) (xy 173.832852 116.639) + (xy 173.128957 116.639) (xy 173.073724 116.616122) (xy 172.423536 115.965934) (xy 172.501281 115.913987) (xy 172.617587 115.797681) + (xy 172.708967 115.660921) (xy 172.751879 115.557322) (xy 174.290992 114.01821) (xy 174.31999 113.994412) (xy 174.414963 113.878687) + (xy 174.485535 113.746658) (xy 174.528992 113.603397) (xy 174.539989 113.491744) (xy 174.539989 113.491735) (xy 174.543665 113.454412) + (xy 174.539989 113.417089) (xy 174.539989 111.972157) (xy 174.5829 111.86856) (xy 174.584169 111.862178) (xy 174.849721 111.915) + (xy 175.270279 111.915) (xy 175.682756 111.832953) (xy 176.071302 111.672012) (xy 176.420983 111.438363) (xy 176.718363 111.140983) + (xy 176.952012 110.791302) (xy 177.112953 110.402756) (xy 177.195 109.990279) (xy 177.195 109.569721) (xy 177.112953 109.157244) + (xy 176.952012 108.768698) (xy 176.718363 108.419017) (xy 176.420983 108.121637) (xy 176.071302 107.887988) (xy 175.855698 107.798682) + (xy 175.925 107.45028) (xy 175.925 107.029722) (xy 175.873463 106.770627) (xy 175.888412 106.785576) (xy 176.328175 107.079417) + (xy 176.816814 107.281817) (xy 177.335551 107.385) (xy 177.864449 107.385) (xy 178.383186 107.281817) (xy 178.871825 107.079417) + (xy 179.311588 106.785576) (xy 179.326537 106.770627) + ) + ) + (filled_polygon + (pts + (xy 168.136928 104.575) (xy 168.149188 104.699482) (xy 168.185498 104.81918) (xy 168.244463 104.929494) (xy 168.323815 105.026185) + (xy 168.420506 105.105537) (xy 168.53082 105.164502) (xy 168.650518 105.200812) (xy 168.775 105.213072) (xy 169.46327 105.213072) + (xy 169.840001 105.589803) (xy 169.840001 105.641928) (xy 169.45 105.641928) (xy 169.325518 105.654188) (xy 169.20582 105.690498) + (xy 169.095506 105.749463) (xy 168.998815 105.828815) (xy 168.919463 105.925506) (xy 168.860498 106.03582) (xy 168.824188 106.155518) + (xy 168.811928 106.28) (xy 168.811928 108.28) (xy 168.824188 108.404482) (xy 168.860498 108.52418) (xy 168.919463 108.634494) + (xy 168.998815 108.731185) (xy 169.095506 108.810537) (xy 169.0962 108.810908) (xy 169.065 108.96776) (xy 169.065 109.13224) + (xy 169.097089 109.29356) (xy 169.160033 109.445521) (xy 169.251413 109.582281) (xy 169.367719 109.698587) (xy 169.504479 109.789967) + (xy 169.65644 109.852911) (xy 169.81776 109.885) (xy 169.98224 109.885) (xy 170.14356 109.852911) (xy 170.295521 109.789967) + (xy 170.432281 109.698587) (xy 170.548587 109.582281) (xy 170.639967 109.445521) (xy 170.702911 109.29356) (xy 170.735 109.13224) + (xy 170.735 108.96776) (xy 170.725116 108.918072) (xy 171.75 108.918072) (xy 171.874482 108.905812) (xy 171.99418 108.869502) + (xy 172.104494 108.810537) (xy 172.201185 108.731185) (xy 172.228525 108.697872) (xy 172.429017 108.898364) (xy 172.778698 109.132013) + (xy 172.994302 109.221319) (xy 172.925 109.569721) (xy 172.925 109.990279) (xy 173.007047 110.402756) (xy 173.167988 110.791302) + (xy 173.278104 110.956103) (xy 173.247708 110.976413) (xy 173.131402 111.092719) (xy 173.040022 111.229479) (xy 172.977078 111.38144) + (xy 172.944989 111.54276) (xy 172.944989 111.70724) (xy 172.977078 111.86856) (xy 173.019989 111.972157) (xy 173.01999 113.139608) + (xy 171.677078 114.482521) (xy 171.573479 114.525433) (xy 171.436719 114.616813) (xy 171.320413 114.733119) (xy 171.268466 114.810864) + (xy 168.593614 112.136013) (xy 168.606311 112.10536) (xy 168.6384 111.94404) (xy 168.6384 111.77956) (xy 168.606311 111.61824) + (xy 168.543367 111.466279) (xy 168.451987 111.329519) (xy 168.335681 111.213213) (xy 168.198921 111.121833) (xy 168.04696 111.058889) + (xy 167.88564 111.0268) (xy 167.76 111.0268) (xy 167.76 104.779799) (xy 168.136928 104.402872) + ) + ) + (filled_polygon + (pts + (xy 210.578411 46.740313) (xy 210.660589 46.894059) (xy 210.713887 46.959002) (xy 210.771183 47.028817) (xy 210.865445 47.106176) + (xy 210.905942 47.139411) (xy 211.059688 47.221589) (xy 211.168094 47.254474) (xy 211.206426 47.266102) (xy 211.260033 47.395521) + (xy 211.351413 47.532281) (xy 211.467719 47.648587) (xy 211.604479 47.739967) (xy 211.75644 47.802911) (xy 211.91776 47.835) + (xy 211.960199 47.835) (xy 211.961928 47.836729) (xy 211.961928 48.275) (xy 211.974188 48.399482) (xy 212.010498 48.51918) + (xy 212.058312 48.608633) (xy 211.997089 48.75644) (xy 211.965 48.91776) (xy 211.965 49.08224) (xy 211.997089 49.24356) + (xy 212.060033 49.395521) (xy 212.151413 49.532281) (xy 212.267719 49.648587) (xy 212.404479 49.739967) (xy 212.55644 49.802911) + (xy 212.71776 49.835) (xy 212.88224 49.835) (xy 213.04356 49.802911) (xy 213.195521 49.739967) (xy 213.332281 49.648587) + (xy 213.391195 49.589673) (xy 213.445525 49.655875) (xy 213.524337 49.720554) (xy 213.553637 49.7446) (xy 213.67698 49.810528) + (xy 213.810816 49.851127) (xy 213.95 49.864835) (xy 213.984877 49.8614) (xy 214.912478 49.8614) (xy 214.528175 50.020583) + (xy 214.088412 50.314424) (xy 213.714424 50.688412) (xy 213.635 50.807278) (xy 213.635 50.71776) (xy 213.602911 50.55644) + (xy 213.539967 50.404479) (xy 213.448587 50.267719) (xy 213.332281 50.151413) (xy 213.195521 50.060033) (xy 213.04356 49.997089) + (xy 212.88224 49.965) (xy 212.71776 49.965) (xy 212.55644 49.997089) (xy 212.404479 50.060033) (xy 212.267719 50.151413) + (xy 212.151413 50.267719) (xy 212.060033 50.404479) (xy 211.997089 50.55644) (xy 211.965 50.71776) (xy 211.965 50.88224) + (xy 211.997089 51.04356) (xy 212.017836 51.093649) (xy 212.003411 51.08401) (xy 211.733158 50.972068) (xy 211.44626 50.915) + (xy 211.276697 50.915) (xy 211.182327 50.875911) (xy 210.876109 50.815) (xy 210.563891 50.815) (xy 210.257673 50.875911) + (xy 209.969221 50.995391) (xy 209.709621 51.16885) (xy 209.48885 51.389621) (xy 209.315391 51.649221) (xy 209.195911 51.937673) + (xy 209.135 52.243891) (xy 209.135 52.556109) (xy 209.195911 52.862327) (xy 209.315391 53.150779) (xy 209.443113 53.341928) + (xy 208.512166 53.341928) (xy 208.552911 53.24356) (xy 208.585 53.08224) (xy 208.585 52.976018) (xy 208.676185 52.901185) + (xy 208.755537 52.804494) (xy 208.814502 52.69418) (xy 208.850812 52.574482) (xy 208.863072 52.45) (xy 208.863072 51.15) + (xy 208.850812 51.025518) (xy 208.814502 50.90582) (xy 208.755537 50.795506) (xy 208.676185 50.698815) (xy 208.579494 50.619463) + (xy 208.46918 50.560498) (xy 208.349482 50.524188) (xy 208.225 50.511928) (xy 207.275 50.511928) (xy 207.150518 50.524188) + (xy 207.03082 50.560498) (xy 206.920506 50.619463) (xy 206.823815 50.698815) (xy 206.744463 50.795506) (xy 206.685498 50.90582) + (xy 206.649188 51.025518) (xy 206.636928 51.15) (xy 206.636928 52.45) (xy 206.649188 52.574482) (xy 206.685498 52.69418) + (xy 206.744463 52.804494) (xy 206.823815 52.901185) (xy 206.915 52.976018) (xy 206.915 53.08224) (xy 206.947089 53.24356) + (xy 206.990001 53.347158) (xy 206.99 53.992677) (xy 206.986324 54.03) (xy 206.99 54.067322) (xy 206.99 54.067332) + (xy 207.000997 54.178985) (xy 207.011928 54.21502) (xy 207.011928 55.98) (xy 207.024188 56.104482) (xy 207.060498 56.22418) + (xy 207.119463 56.334494) (xy 207.198815 56.431185) (xy 207.295506 56.510537) (xy 207.40582 56.569502) (xy 207.525518 56.605812) + (xy 207.65 56.618072) (xy 208.062565 56.618072) (xy 208.065026 56.622676) (xy 208.134558 56.7074) (xy 208.16 56.738401) + (xy 208.188998 56.762199) (xy 212.229015 60.802218) (xy 212.252809 60.831211) (xy 212.281802 60.855005) (xy 212.281806 60.855009) + (xy 212.350255 60.911183) (xy 212.368534 60.926184) (xy 212.500563 60.996756) (xy 212.643824 61.040213) (xy 212.755477 61.05121) + (xy 212.755486 61.05121) (xy 212.792809 61.054886) (xy 212.830132 61.05121) (xy 214.308243 61.05121) (xy 214.41184 61.094121) + (xy 214.57316 61.12621) (xy 214.73764 61.12621) (xy 214.89896 61.094121) (xy 215.050921 61.031177) (xy 215.187681 60.939797) + (xy 215.303987 60.823491) (xy 215.328801 60.786354) (xy 215.328801 61.251468) (xy 215.325124 61.2888) (xy 215.328801 61.326133) + (xy 215.339798 61.437786) (xy 215.346901 61.461201) (xy 215.383254 61.581046) (xy 215.453826 61.713076) (xy 215.512849 61.784995) + (xy 215.5488 61.828801) (xy 215.577798 61.852599) (xy 216.541199 62.816) (xy 213.984877 62.816) (xy 213.95 62.812565) + (xy 213.915123 62.816) (xy 213.810816 62.826273) (xy 213.67698 62.866872) (xy 213.553637 62.9328) (xy 213.445525 63.021525) + (xy 213.3568 63.129637) (xy 213.290872 63.25298) (xy 213.250273 63.386816) (xy 213.236565 63.526) (xy 213.240001 63.560887) + (xy 213.240001 63.786928) (xy 212.5 63.786928) (xy 212.375518 63.799188) (xy 212.25582 63.835498) (xy 212.145506 63.894463) + (xy 212.048815 63.973815) (xy 211.969463 64.070506) (xy 211.910498 64.18082) (xy 211.874188 64.300518) (xy 211.861928 64.425) + (xy 211.861928 64.636493) (xy 211.283422 65.215) (xy 209.893469 65.215) (xy 209.85 65.210719) (xy 209.806531 65.215) + (xy 209.806523 65.215) (xy 209.67651 65.227805) (xy 209.509687 65.278411) (xy 209.355941 65.360589) (xy 209.221183 65.471183) + (xy 209.193468 65.504954) (xy 208.908422 65.79) (xy 208.863072 65.79) (xy 208.863072 64.85) (xy 208.850812 64.725518) + (xy 208.814502 64.60582) (xy 208.755537 64.495506) (xy 208.676185 64.398815) (xy 208.579494 64.319463) (xy 208.46918 64.260498) + (xy 208.349482 64.224188) (xy 208.225 64.211928) (xy 207.275 64.211928) (xy 207.246148 64.21477) (xy 207.413928 64.145273) + (xy 207.902826 63.818601) (xy 208.318601 63.402826) (xy 208.645273 62.913928) (xy 208.870288 62.370692) (xy 208.985 61.793997) + (xy 208.985 61.206003) (xy 208.870288 60.629308) (xy 208.645273 60.086072) (xy 208.318601 59.597174) (xy 207.902826 59.181399) + (xy 207.413928 58.854727) (xy 206.870692 58.629712) (xy 206.293997 58.515) (xy 205.706003 58.515) (xy 205.129308 58.629712) + (xy 204.586072 58.854727) (xy 204.097174 59.181399) (xy 203.681399 59.597174) (xy 203.354727 60.086072) (xy 203.129712 60.629308) + (xy 203.015 61.206003) (xy 203.015 61.793997) (xy 203.129712 62.370692) (xy 203.354727 62.913928) (xy 203.681399 63.402826) + (xy 204.097174 63.818601) (xy 204.586072 64.145273) (xy 205.129308 64.370288) (xy 205.706003 64.485) (xy 206.293997 64.485) + (xy 206.854699 64.373469) (xy 206.823815 64.398815) (xy 206.744463 64.495506) (xy 206.685498 64.60582) (xy 206.662691 64.681003) + (xy 206.58224 64.665) (xy 206.41776 64.665) (xy 206.25644 64.697089) (xy 206.152843 64.74) (xy 204.412333 64.74) + (xy 204.375 64.736323) (xy 204.337667 64.74) (xy 204.226014 64.750997) (xy 204.082753 64.794454) (xy 203.950724 64.865026) + (xy 203.834999 64.959999) (xy 203.811201 64.988997) (xy 202.273078 66.527121) (xy 202.169479 66.570033) (xy 202.032719 66.661413) + (xy 201.916413 66.777719) (xy 201.825033 66.914479) (xy 201.762089 67.06644) (xy 201.73 67.22776) (xy 201.73 67.39224) + (xy 201.762089 67.55356) (xy 201.825033 67.705521) (xy 201.916413 67.842281) (xy 202.032719 67.958587) (xy 202.169479 68.049967) + (xy 202.32144 68.112911) (xy 202.48276 68.145) (xy 202.64724 68.145) (xy 202.80856 68.112911) (xy 202.960521 68.049967) + (xy 203.097281 67.958587) (xy 203.213587 67.842281) (xy 203.304967 67.705521) (xy 203.347879 67.601922) (xy 204.689802 66.26) + (xy 205.393332 66.26) (xy 205.353411 66.334687) (xy 205.302805 66.50151) (xy 205.285718 66.675) (xy 205.302805 66.84849) + (xy 205.353411 67.015313) (xy 205.435589 67.169059) (xy 205.546183 67.303817) (xy 205.680941 67.414411) (xy 205.834687 67.496589) + (xy 206.00151 67.547195) (xy 206.131523 67.56) (xy 209.231531 67.56) (xy 209.275 67.564281) (xy 209.318469 67.56) + (xy 209.318477 67.56) (xy 209.44849 67.547195) (xy 209.615313 67.496589) (xy 209.769059 67.414411) (xy 209.903817 67.303817) + (xy 209.931534 67.270044) (xy 210.125185 67.076393) (xy 210.148491 67.19356) (xy 210.211435 67.345521) (xy 210.302815 67.482281) + (xy 210.419121 67.598587) (xy 210.555881 67.689967) (xy 210.707842 67.752911) (xy 210.869162 67.785) (xy 211.033642 67.785) + (xy 211.194962 67.752911) (xy 211.346923 67.689967) (xy 211.483683 67.598587) (xy 211.599989 67.482281) (xy 211.631581 67.435) + (xy 211.918954 67.435) (xy 211.969463 67.529494) (xy 212.048815 67.626185) (xy 212.145506 67.705537) (xy 212.25582 67.764502) + (xy 212.375518 67.800812) (xy 212.5 67.813072) (xy 213.24 67.813072) (xy 213.24 67.991123) (xy 213.236565 68.026) + (xy 213.250273 68.165184) (xy 213.290872 68.29902) (xy 213.3568 68.422363) (xy 213.445525 68.530475) (xy 213.553637 68.6192) + (xy 213.67698 68.685128) (xy 213.810816 68.725727) (xy 213.95 68.739435) (xy 213.984877 68.736) (xy 214.8738 68.736) + (xy 214.428175 68.920583) (xy 213.988412 69.214424) (xy 213.614424 69.588412) (xy 213.320583 70.028175) (xy 213.118183 70.516814) + (xy 213.015 71.035551) (xy 213.015 71.564449) (xy 213.118183 72.083186) (xy 213.123749 72.096623) (xy 212.901302 71.947989) + (xy 212.592012 71.819877) (xy 212.627932 71.733158) (xy 212.685 71.44626) (xy 212.685 71.15374) (xy 212.627932 70.866842) + (xy 212.51599 70.596589) (xy 212.353475 70.353368) (xy 212.146632 70.146525) (xy 211.903411 69.98401) (xy 211.633158 69.872068) + (xy 211.34626 69.815) (xy 211.176697 69.815) (xy 211.082327 69.775911) (xy 210.776109 69.715) (xy 210.463891 69.715) + (xy 210.157673 69.775911) (xy 209.869221 69.895391) (xy 209.609621 70.06885) (xy 209.38885 70.289621) (xy 209.215391 70.549221) + (xy 209.095911 70.837673) (xy 209.035 71.143891) (xy 209.035 71.456109) (xy 209.036015 71.461214) (xy 208.51 70.935199) + (xy 208.51 70.847157) (xy 208.552911 70.74356) (xy 208.585 70.58224) (xy 208.585 70.41776) (xy 208.552911 70.25644) + (xy 208.548945 70.246866) (xy 208.579494 70.230537) (xy 208.676185 70.151185) (xy 208.755537 70.054494) (xy 208.814502 69.94418) + (xy 208.850812 69.824482) (xy 208.863072 69.7) (xy 208.863072 68.4) (xy 208.850812 68.275518) (xy 208.814502 68.15582) + (xy 208.755537 68.045506) (xy 208.676185 67.948815) (xy 208.579494 67.869463) (xy 208.46918 67.810498) (xy 208.349482 67.774188) + (xy 208.225 67.761928) (xy 207.275 67.761928) (xy 207.150518 67.774188) (xy 207.03082 67.810498) (xy 206.920506 67.869463) + (xy 206.823815 67.948815) (xy 206.744463 68.045506) (xy 206.685498 68.15582) (xy 206.649188 68.275518) (xy 206.636928 68.4) + (xy 206.636928 69.7) (xy 206.649188 69.824482) (xy 206.685498 69.94418) (xy 206.744463 70.054494) (xy 206.823815 70.151185) + (xy 206.920506 70.230537) (xy 206.951055 70.246866) (xy 206.947089 70.25644) (xy 206.915 70.41776) (xy 206.915 70.58224) + (xy 206.947089 70.74356) (xy 206.99 70.847157) (xy 206.99 71.212678) (xy 206.986324 71.25) (xy 206.99 71.287322) + (xy 206.99 71.287332) (xy 207.000997 71.398985) (xy 207.033156 71.505) (xy 207.044454 71.542246) (xy 207.115026 71.674276) + (xy 207.140241 71.705) (xy 207.209999 71.790001) (xy 207.239002 71.813804) (xy 207.667127 72.241928) (xy 207.55 72.241928) + (xy 207.425518 72.254188) (xy 207.30582 72.290498) (xy 207.195506 72.349463) (xy 207.098815 72.428815) (xy 207.019463 72.525506) + (xy 206.960498 72.63582) (xy 206.924188 72.755518) (xy 206.911928 72.88) (xy 206.911928 74.88) (xy 206.924188 75.004482) + (xy 206.960498 75.12418) (xy 207.019463 75.234494) (xy 207.098815 75.331185) (xy 207.195506 75.410537) (xy 207.30582 75.469502) + (xy 207.425518 75.505812) (xy 207.55 75.518072) (xy 208.045674 75.518072) (xy 208.065026 75.554276) (xy 208.136201 75.641002) + (xy 208.16 75.670001) (xy 208.188998 75.693799) (xy 210.131788 77.636589) (xy 212.08119 79.585992) (xy 212.104988 79.61499) + (xy 212.133986 79.638788) (xy 212.220712 79.709963) (xy 212.339743 79.773587) (xy 212.352742 79.780535) (xy 212.496003 79.823992) + (xy 212.607656 79.834989) (xy 212.607666 79.834989) (xy 212.644989 79.838665) (xy 212.682312 79.834989) (xy 215.679843 79.834989) + (xy 215.78344 79.8779) (xy 215.94476 79.909989) (xy 216.10924 79.909989) (xy 216.27056 79.8779) (xy 216.422521 79.814956) + (xy 216.559281 79.723576) (xy 216.616532 79.666325) (xy 217.340001 80.389794) (xy 217.340001 82.0795) (xy 213.984877 82.0795) + (xy 213.95 82.076065) (xy 213.915123 82.0795) (xy 213.810816 82.089773) (xy 213.67698 82.130372) (xy 213.553637 82.1963) + (xy 213.445525 82.285025) (xy 213.3568 82.393137) (xy 213.290872 82.51648) (xy 213.250273 82.650316) (xy 213.236565 82.7895) + (xy 213.240001 82.824387) (xy 213.240001 82.986928) (xy 212.5 82.986928) (xy 212.375518 82.999188) (xy 212.25582 83.035498) + (xy 212.145506 83.094463) (xy 212.048815 83.173815) (xy 211.994499 83.24) (xy 211.956467 83.24) (xy 211.912998 83.235719) + (xy 211.869529 83.24) (xy 211.869521 83.24) (xy 211.739508 83.252805) (xy 211.572685 83.303411) (xy 211.464336 83.361324) + (xy 211.418939 83.385589) (xy 211.317951 83.468468) (xy 211.317949 83.46847) (xy 211.284181 83.496183) (xy 211.256468 83.529951) + (xy 210.279956 84.506464) (xy 210.246183 84.534181) (xy 210.135589 84.66894) (xy 210.053411 84.822686) (xy 210.02457 84.91776) + (xy 210.002805 84.989508) (xy 210.00172 85.000521) (xy 209.99 85.119522) (xy 209.99 85.119529) (xy 209.985719 85.162998) + (xy 209.99 85.206467) (xy 209.99 85.918477) (xy 210.002805 86.04849) (xy 210.053412 86.215313) (xy 210.13559 86.369059) + (xy 210.246184 86.503817) (xy 210.380942 86.614411) (xy 210.534688 86.696589) (xy 210.701511 86.747195) (xy 210.875 86.764282) + (xy 211.04849 86.747195) (xy 211.215313 86.696589) (xy 211.369059 86.614411) (xy 211.503817 86.503817) (xy 211.614411 86.369059) + (xy 211.696589 86.215313) (xy 211.747195 86.04849) (xy 211.76 85.918477) (xy 211.76 85.834801) (xy 211.861928 85.936729) + (xy 211.861928 86.375) (xy 211.874188 86.499482) (xy 211.910498 86.61918) (xy 211.969463 86.729494) (xy 212.048815 86.826185) + (xy 212.145506 86.905537) (xy 212.25582 86.964502) (xy 212.375518 87.000812) (xy 212.5 87.013072) (xy 212.54 87.013072) + (xy 212.540001 89.854556) (xy 212.51599 89.796589) (xy 212.353475 89.553368) (xy 212.146632 89.346525) (xy 211.903411 89.18401) + (xy 211.633158 89.072068) (xy 211.34626 89.015) (xy 211.176697 89.015) (xy 211.082327 88.975911) (xy 210.776109 88.915) + (xy 210.463891 88.915) (xy 210.157673 88.975911) (xy 209.869221 89.095391) (xy 209.609621 89.26885) (xy 209.38885 89.489621) + (xy 209.215391 89.749221) (xy 209.095911 90.037673) (xy 209.035 90.343891) (xy 209.035 90.656109) (xy 209.095911 90.962327) + (xy 209.137476 91.062674) (xy 208.51 90.435199) (xy 208.51 89.597157) (xy 208.552911 89.49356) (xy 208.585 89.33224) + (xy 208.585 89.226018) (xy 208.676185 89.151185) (xy 208.755537 89.054494) (xy 208.814502 88.94418) (xy 208.850812 88.824482) + (xy 208.863072 88.7) (xy 208.863072 87.4) (xy 208.850812 87.275518) (xy 208.814502 87.15582) (xy 208.755537 87.045506) + (xy 208.676185 86.948815) (xy 208.579494 86.869463) (xy 208.46918 86.810498) (xy 208.349482 86.774188) (xy 208.225 86.761928) + (xy 207.275 86.761928) (xy 207.150518 86.774188) (xy 207.03082 86.810498) (xy 206.920506 86.869463) (xy 206.823815 86.948815) + (xy 206.744463 87.045506) (xy 206.685498 87.15582) (xy 206.649188 87.275518) (xy 206.636928 87.4) (xy 206.636928 88.7) + (xy 206.649188 88.824482) (xy 206.685498 88.94418) (xy 206.744463 89.054494) (xy 206.823815 89.151185) (xy 206.915 89.226018) + (xy 206.915 89.33224) (xy 206.947089 89.49356) (xy 206.990001 89.597159) (xy 206.99 90.712677) (xy 206.986324 90.75) + (xy 206.99 90.787322) (xy 206.99 90.787332) (xy 207.000997 90.898985) (xy 207.035354 91.012246) (xy 207.044454 91.042246) + (xy 207.115026 91.174276) (xy 207.150679 91.217719) (xy 207.209999 91.290001) (xy 207.239002 91.313804) (xy 207.390124 91.464925) + (xy 207.30582 91.490498) (xy 207.195506 91.549463) (xy 207.098815 91.628815) (xy 207.019463 91.725506) (xy 206.960498 91.83582) + (xy 206.924188 91.955518) (xy 206.911928 92.08) (xy 206.911928 94.08) (xy 206.924188 94.204482) (xy 206.960498 94.32418) + (xy 207.019463 94.434494) (xy 207.098815 94.531185) (xy 207.195506 94.610537) (xy 207.30582 94.669502) (xy 207.425518 94.705812) + (xy 207.55 94.718072) (xy 207.940001 94.718072) (xy 207.94 96.412677) (xy 207.936324 96.45) (xy 207.94 96.487322) + (xy 207.94 96.487332) (xy 207.950997 96.598985) (xy 207.992136 96.734603) (xy 207.994454 96.742246) (xy 208.065026 96.874276) + (xy 208.095014 96.910816) (xy 208.159999 96.990001) (xy 208.189002 97.013804) (xy 208.967122 97.791923) (xy 209.010033 97.895521) + (xy 209.101413 98.032281) (xy 209.217719 98.148587) (xy 209.354479 98.239967) (xy 209.50644 98.302911) (xy 209.66776 98.335) + (xy 209.83224 98.335) (xy 209.99356 98.302911) (xy 210.145521 98.239967) (xy 210.282281 98.148587) (xy 210.398587 98.032281) + (xy 210.489967 97.895521) (xy 210.552911 97.74356) (xy 210.585 97.58224) (xy 210.585 97.41776) (xy 210.552911 97.25644) + (xy 210.489967 97.104479) (xy 210.398587 96.967719) (xy 210.282281 96.851413) (xy 210.145521 96.760033) (xy 210.041923 96.717122) + (xy 209.46 96.135199) (xy 209.46 94.718072) (xy 209.85 94.718072) (xy 209.974482 94.705812) (xy 210.09418 94.669502) + (xy 210.204494 94.610537) (xy 210.301185 94.531185) (xy 210.328525 94.497872) (xy 210.529017 94.698364) (xy 210.878698 94.932013) + (xy 211.094302 95.021319) (xy 211.025 95.369721) (xy 211.025 95.790279) (xy 211.107047 96.202756) (xy 211.267988 96.591302) + (xy 211.501637 96.940983) (xy 211.799017 97.238363) (xy 212.148698 97.472012) (xy 212.537244 97.632953) (xy 212.949721 97.715) + (xy 213.370279 97.715) (xy 213.782756 97.632953) (xy 214.171302 97.472012) (xy 214.520983 97.238363) (xy 214.818363 96.940983) + (xy 215.052012 96.591302) (xy 215.212953 96.202756) (xy 215.295 95.790279) (xy 215.295 95.369721) (xy 215.212953 94.957244) + (xy 215.052012 94.568698) (xy 214.818363 94.219017) (xy 214.520983 93.921637) (xy 214.171302 93.687988) (xy 213.955698 93.598682) + (xy 213.997704 93.387507) (xy 215.654999 95.044803) (xy 215.655 96.977667) (xy 215.651323 97.014999) (xy 215.655 97.052332) + (xy 215.664673 97.150537) (xy 215.665997 97.163984) (xy 215.709453 97.307245) (xy 215.780025 97.439275) (xy 215.845827 97.519454) + (xy 215.874999 97.555) (xy 215.903997 97.578798) (xy 219.09 100.764802) (xy 219.090001 102.003896) (xy 219.074482 101.999188) + (xy 218.95 101.986928) (xy 218.21 101.986928) (xy 218.21 101.760877) (xy 218.213435 101.726) (xy 218.199727 101.586816) + (xy 218.159128 101.45298) (xy 218.0932 101.329637) (xy 218.004475 101.221525) (xy 217.896363 101.1328) (xy 217.77302 101.066872) + (xy 217.639184 101.026273) (xy 217.534877 101.016) (xy 217.5 101.012565) (xy 217.465123 101.016) (xy 214.034877 101.016) + (xy 214 101.012565) (xy 213.965123 101.016) (xy 213.860816 101.026273) (xy 213.72698 101.066872) (xy 213.603637 101.1328) + (xy 213.495525 101.221525) (xy 213.4068 101.329637) (xy 213.340872 101.45298) (xy 213.300273 101.586816) (xy 213.286565 101.726) + (xy 213.290001 101.760887) (xy 213.290001 101.986928) (xy 212.55 101.986928) (xy 212.425518 101.999188) (xy 212.30582 102.035498) + (xy 212.195506 102.094463) (xy 212.098815 102.173815) (xy 212.044499 102.24) (xy 212.018466 102.24) (xy 211.974999 102.235719) + (xy 211.931533 102.24) (xy 211.931523 102.24) (xy 211.80151 102.252805) (xy 211.634687 102.303411) (xy 211.480941 102.385589) + (xy 211.346183 102.496183) (xy 211.318466 102.529956) (xy 211.004956 102.843466) (xy 210.971183 102.871183) (xy 210.860589 103.005942) + (xy 210.778411 103.159688) (xy 210.75498 103.236928) (xy 210.728483 103.324277) (xy 210.727805 103.326511) (xy 210.715 103.456524) + (xy 210.715 103.456531) (xy 210.710719 103.5) (xy 210.715 103.54347) (xy 210.715001 104.806521) (xy 210.710719 104.85) + (xy 210.727805 105.02349) (xy 210.778412 105.190313) (xy 210.86059 105.344059) (xy 210.943468 105.445046) (xy 210.943471 105.445049) + (xy 210.971184 105.478817) (xy 211.004952 105.50653) (xy 211.029954 105.531532) (xy 211.119872 105.605326) (xy 209.313072 107.412126) + (xy 209.313072 106.3) (xy 209.300812 106.175518) (xy 209.264502 106.05582) (xy 209.205537 105.945506) (xy 209.126185 105.848815) + (xy 209.029494 105.769463) (xy 208.91918 105.710498) (xy 208.799482 105.674188) (xy 208.675 105.661928) (xy 207.725 105.661928) + (xy 207.600518 105.674188) (xy 207.48082 105.710498) (xy 207.370506 105.769463) (xy 207.273815 105.848815) (xy 207.194463 105.945506) + (xy 207.135498 106.05582) (xy 207.099188 106.175518) (xy 207.086928 106.3) (xy 207.086928 106.943857) (xy 207.086323 106.95) + (xy 207.086928 106.956143) (xy 207.086928 107.6) (xy 207.099188 107.724482) (xy 207.135498 107.84418) (xy 207.194463 107.954494) + (xy 207.240001 108.009982) (xy 207.240001 108.252841) (xy 207.197089 108.35644) (xy 207.165 108.51776) (xy 207.165 108.68224) + (xy 207.197089 108.84356) (xy 207.260033 108.995521) (xy 207.351413 109.132281) (xy 207.467719 109.248587) (xy 207.47305 109.252149) + (xy 205.991003 110.734196) (xy 205.961999 110.757999) (xy 205.911923 110.819017) (xy 205.867026 110.873724) (xy 205.812503 110.975729) + (xy 205.796454 111.005754) (xy 205.752997 111.149015) (xy 205.742 111.260668) (xy 205.742 111.260678) (xy 205.738324 111.298) + (xy 205.742 111.335323) (xy 205.742001 113.032697) (xy 204.188072 114.586627) (xy 204.188072 113.901426) (xy 204.234974 113.844276) + (xy 204.305546 113.712247) (xy 204.349003 113.568986) (xy 204.36 113.457333) (xy 204.36 113.457324) (xy 204.363676 113.420001) + (xy 204.36 113.382678) (xy 204.36 110.347157) (xy 204.402911 110.24356) (xy 204.435 110.08224) (xy 204.435 109.91776) + (xy 204.402911 109.75644) (xy 204.339967 109.604479) (xy 204.248587 109.467719) (xy 204.132281 109.351413) (xy 203.995521 109.260033) + (xy 203.84356 109.197089) (xy 203.68224 109.165) (xy 203.51776 109.165) (xy 203.35644 109.197089) (xy 203.33737 109.204988) + (xy 203.304089 109.037673) (xy 203.184609 108.749221) (xy 203.01115 108.489621) (xy 202.790379 108.26885) (xy 202.530779 108.095391) + (xy 202.242327 107.975911) (xy 201.936109 107.915) (xy 201.623891 107.915) (xy 201.317673 107.975911) (xy 201.223303 108.015) + (xy 201.05374 108.015) (xy 200.766842 108.072068) (xy 200.496589 108.18401) (xy 200.253368 108.346525) (xy 200.046525 108.553368) + (xy 199.88401 108.796589) (xy 199.772068 109.066842) (xy 199.715 109.35374) (xy 199.715 109.64626) (xy 199.772068 109.933158) + (xy 199.807988 110.019876) (xy 199.498698 110.147988) (xy 199.276252 110.296622) (xy 199.281817 110.283186) (xy 199.385 109.764449) + (xy 199.385 109.235551) (xy 199.281817 108.716814) (xy 199.079417 108.228175) (xy 198.798349 107.807527) (xy 198.898585 107.707291) + (xy 198.989965 107.570531) (xy 199.052909 107.41857) (xy 199.054612 107.41001) (xy 203.112668 107.41001) (xy 203.14999 107.413686) + (xy 203.187312 107.41001) (xy 203.187323 107.41001) (xy 203.298976 107.399013) (xy 203.442237 107.355556) (xy 203.574266 107.284984) + (xy 203.689991 107.190011) (xy 203.713794 107.161007) (xy 205.163799 105.711003) (xy 205.163803 105.710998) (xy 206.091924 104.782878) + (xy 206.195521 104.739967) (xy 206.332281 104.648587) (xy 206.448587 104.532281) (xy 206.539967 104.395521) (xy 206.602911 104.24356) + (xy 206.635 104.08224) (xy 206.635 103.995354) (xy 206.662478 104.013714) (xy 206.814439 104.076658) (xy 206.851901 104.08411) + (xy 206.892005 104.105546) (xy 207.035266 104.149003) (xy 207.09728 104.155111) (xy 207.099188 104.174482) (xy 207.135498 104.29418) + (xy 207.194463 104.404494) (xy 207.273815 104.501185) (xy 207.370506 104.580537) (xy 207.48082 104.639502) (xy 207.600518 104.675812) + (xy 207.725 104.688072) (xy 208.675 104.688072) (xy 208.799482 104.675812) (xy 208.91918 104.639502) (xy 209.029494 104.580537) + (xy 209.126185 104.501185) (xy 209.205537 104.404494) (xy 209.264502 104.29418) (xy 209.300812 104.174482) (xy 209.313072 104.05) + (xy 209.313072 102.75) (xy 209.300812 102.625518) (xy 209.264502 102.50582) (xy 209.205537 102.395506) (xy 209.126185 102.298815) + (xy 209.029494 102.219463) (xy 208.91918 102.160498) (xy 208.799482 102.124188) (xy 208.675 102.111928) (xy 208.109499 102.111928) + (xy 208.318601 101.902826) (xy 208.645273 101.413928) (xy 208.870288 100.870692) (xy 208.985 100.293997) (xy 208.985 99.706003) + (xy 208.870288 99.129308) (xy 208.645273 98.586072) (xy 208.318601 98.097174) (xy 207.902826 97.681399) (xy 207.413928 97.354727) + (xy 206.870692 97.129712) (xy 206.293997 97.015) (xy 205.706003 97.015) (xy 205.129308 97.129712) (xy 204.586072 97.354727) + (xy 204.097174 97.681399) (xy 203.681399 98.097174) (xy 203.354727 98.586072) (xy 203.129712 99.129308) (xy 203.015 99.706003) + (xy 203.015 100.293997) (xy 203.118503 100.814343) (xy 203.071588 100.659685) (xy 202.98941 100.50594) (xy 202.878817 100.371181) + (xy 202.744058 100.260588) (xy 202.590313 100.17841) (xy 202.423489 100.127804) (xy 202.249999 100.110717) (xy 202.076509 100.127804) + (xy 201.909687 100.17841) (xy 201.755941 100.260588) (xy 201.689644 100.314997) (xy 194.800996 100.314997) (xy 194.757527 100.310716) + (xy 194.714058 100.314997) (xy 194.71405 100.314997) (xy 194.584037 100.327802) (xy 194.417214 100.378408) (xy 194.263468 100.460586) + (xy 194.12871 100.57118) (xy 194.100995 100.604951) (xy 193.704952 101.000994) (xy 193.671184 101.028707) (xy 193.643471 101.062475) + (xy 193.643468 101.062478) (xy 193.56059 101.163465) (xy 193.478412 101.317211) (xy 193.427805 101.484034) (xy 193.410719 101.657524) + (xy 193.415001 101.701003) (xy 193.415001 101.995299) (xy 193.375518 101.999188) (xy 193.25582 102.035498) (xy 193.145506 102.094463) + (xy 193.048815 102.173815) (xy 192.994499 102.24) (xy 192.868469 102.24) (xy 192.825 102.235719) (xy 192.781531 102.24) + (xy 192.781523 102.24) (xy 192.65151 102.252805) (xy 192.484687 102.303411) (xy 192.348887 102.375997) (xy 192.330941 102.385589) + (xy 192.229953 102.468468) (xy 192.229951 102.46847) (xy 192.196183 102.496183) (xy 192.16847 102.529951) (xy 191.504956 103.193466) + (xy 191.471183 103.221183) (xy 191.360589 103.355942) (xy 191.278411 103.509688) (xy 191.249656 103.604479) (xy 191.22851 103.674188) + (xy 191.227805 103.676511) (xy 191.215 103.806524) (xy 191.215 103.806531) (xy 191.210719 103.85) (xy 191.215 103.893469) + (xy 191.215 104.043477) (xy 191.227805 104.17349) (xy 191.278411 104.340313) (xy 191.360589 104.494059) (xy 191.471183 104.628817) + (xy 191.605942 104.739411) (xy 191.759688 104.821589) (xy 191.926511 104.872195) (xy 192.1 104.889282) (xy 192.27349 104.872195) + (xy 192.324625 104.856683) (xy 192.329081 104.871373) (xy 192.399653 105.003403) (xy 192.420494 105.028797) (xy 192.494626 105.119128) + (xy 192.52363 105.142931) (xy 192.741696 105.360997) (xy 192.765499 105.390001) (xy 192.872015 105.477416) (xy 192.874188 105.499482) + (xy 192.910498 105.61918) (xy 192.969463 105.729494) (xy 193.048815 105.826185) (xy 193.126586 105.89001) (xy 190.489812 105.89001) + (xy 190.170379 105.570577) (xy 190.127467 105.466979) (xy 190.036087 105.330219) (xy 189.919781 105.213913) (xy 189.783021 105.122533) + (xy 189.679423 105.079622) (xy 189.613072 105.01327) (xy 189.613072 104.325) (xy 189.600812 104.200518) (xy 189.564502 104.08082) + (xy 189.505537 103.970506) (xy 189.426185 103.873815) (xy 189.329494 103.794463) (xy 189.26 103.757317) (xy 189.26 97.037323) + (xy 189.263676 97) (xy 189.26 96.962677) (xy 189.26 96.962667) (xy 189.249003 96.851014) (xy 189.205546 96.707753) + (xy 189.195514 96.688985) (xy 189.134974 96.575723) (xy 189.063799 96.488997) (xy 189.040001 96.459999) (xy 189.011003 96.436201) + (xy 186.820707 94.245906) (xy 186.802911 94.15644) (xy 186.739967 94.004479) (xy 186.648587 93.867719) (xy 186.532281 93.751413) + (xy 186.395521 93.660033) (xy 186.24356 93.597089) (xy 186.234999 93.595386) (xy 186.234999 88.739802) (xy 187.386928 87.587875) + (xy 187.386928 87.65) (xy 187.399188 87.774482) (xy 187.435498 87.89418) (xy 187.494463 88.004494) (xy 187.573815 88.101185) + (xy 187.665 88.176018) (xy 187.665 88.33224) (xy 187.697089 88.49356) (xy 187.760033 88.645521) (xy 187.851413 88.782281) + (xy 187.967719 88.898587) (xy 188.104479 88.989967) (xy 188.25644 89.052911) (xy 188.41776 89.085) (xy 188.58224 89.085) + (xy 188.74356 89.052911) (xy 188.895521 88.989967) (xy 189.032281 88.898587) (xy 189.148587 88.782281) (xy 189.239967 88.645521) + (xy 189.302911 88.49356) (xy 189.335 88.33224) (xy 189.335 88.263) (xy 194.333247 88.263) (xy 194.360035 88.284984) + (xy 194.492064 88.355556) (xy 194.635325 88.399013) (xy 194.746978 88.41001) (xy 194.784311 88.413687) (xy 194.821644 88.41001) + (xy 194.995018 88.41001) (xy 194.988412 88.414424) (xy 194.614424 88.788412) (xy 194.320583 89.228175) (xy 194.118183 89.716814) + (xy 194.015 90.235551) (xy 194.015 90.764449) (xy 194.118183 91.283186) (xy 194.123749 91.296623) (xy 193.901302 91.147989) + (xy 193.592012 91.019877) (xy 193.627932 90.933158) (xy 193.685 90.64626) (xy 193.685 90.35374) (xy 193.627932 90.066842) + (xy 193.51599 89.796589) (xy 193.353475 89.553368) (xy 193.146632 89.346525) (xy 192.903411 89.18401) (xy 192.633158 89.072068) + (xy 192.34626 89.015) (xy 192.176697 89.015) (xy 192.082327 88.975911) (xy 191.776109 88.915) (xy 191.463891 88.915) + (xy 191.157673 88.975911) (xy 190.869221 89.095391) (xy 190.609621 89.26885) (xy 190.38885 89.489621) (xy 190.215391 89.749221) + (xy 190.095911 90.037673) (xy 190.035 90.343891) (xy 190.035 90.656109) (xy 190.095911 90.962327) (xy 190.215391 91.250779) + (xy 190.343113 91.441928) (xy 189.565185 91.441928) (xy 189.600812 91.324482) (xy 189.613072 91.2) (xy 189.613072 89.9) + (xy 189.600812 89.775518) (xy 189.564502 89.65582) (xy 189.505537 89.545506) (xy 189.426185 89.448815) (xy 189.329494 89.369463) + (xy 189.21918 89.310498) (xy 189.099482 89.274188) (xy 188.975 89.261928) (xy 188.025 89.261928) (xy 187.900518 89.274188) + (xy 187.78082 89.310498) (xy 187.670506 89.369463) (xy 187.573815 89.448815) (xy 187.494463 89.545506) (xy 187.435498 89.65582) + (xy 187.399188 89.775518) (xy 187.386928 89.9) (xy 187.386928 91.2) (xy 187.399188 91.324482) (xy 187.435498 91.44418) + (xy 187.494463 91.554494) (xy 187.573815 91.651185) (xy 187.665 91.726018) (xy 187.665 91.83224) (xy 187.697089 91.99356) + (xy 187.760033 92.145521) (xy 187.851413 92.282281) (xy 187.855401 92.286269) (xy 187.865026 92.304276) (xy 187.911928 92.361426) + (xy 187.911928 94.08) (xy 187.924188 94.204482) (xy 187.960498 94.32418) (xy 188.019463 94.434494) (xy 188.098815 94.531185) + (xy 188.195506 94.610537) (xy 188.30582 94.669502) (xy 188.425518 94.705812) (xy 188.55 94.718072) (xy 188.967859 94.718072) + (xy 188.994454 94.805746) (xy 189.065026 94.937776) (xy 189.135789 95.024) (xy 189.16 95.053501) (xy 189.188998 95.077299) + (xy 193.222701 99.111003) (xy 193.246499 99.140001) (xy 193.362224 99.234974) (xy 193.494253 99.305546) (xy 193.637514 99.349003) + (xy 193.749167 99.36) (xy 193.749175 99.36) (xy 193.7865 99.363676) (xy 193.823825 99.36) (xy 201.028048 99.36) + (xy 201.06537 99.363676) (xy 201.102692 99.36) (xy 201.102703 99.36) (xy 201.214356 99.349003) (xy 201.357617 99.305546) + (xy 201.489646 99.234974) (xy 201.605371 99.140001) (xy 201.629173 99.110998) (xy 202.308471 98.431701) (xy 202.337468 98.407904) + (xy 202.432441 98.292179) (xy 202.503013 98.16015) (xy 202.54647 98.016889) (xy 202.557467 97.905236) (xy 202.557467 97.905235) + (xy 202.561144 97.867903) (xy 202.557467 97.83057) (xy 202.557467 97.506036) (xy 202.600378 97.402439) (xy 202.629095 97.258072) + (xy 203.55 97.258072) (xy 203.674482 97.245812) (xy 203.79418 97.209502) (xy 203.904494 97.150537) (xy 204.001185 97.071185) + (xy 204.080537 96.974494) (xy 204.139502 96.86418) (xy 204.175812 96.744482) (xy 204.188072 96.62) (xy 204.188072 94.62) + (xy 204.175812 94.495518) (xy 204.139502 94.37582) (xy 204.080537 94.265506) (xy 204.001185 94.168815) (xy 203.904494 94.089463) + (xy 203.801873 94.03461) (xy 203.834974 93.994276) (xy 203.905546 93.862247) (xy 203.949003 93.718986) (xy 203.96 93.607333) + (xy 203.96 93.607323) (xy 203.963676 93.57) (xy 203.96 93.532677) (xy 203.96 87.532657) (xy 204.002911 87.42906) + (xy 204.035 87.26774) (xy 204.035 87.10326) (xy 204.002911 86.94194) (xy 203.939967 86.789979) (xy 203.848587 86.653219) + (xy 203.846583 86.651215) (xy 205.237798 85.26) (xy 206.477843 85.26) (xy 206.58144 85.302911) (xy 206.662716 85.319078) + (xy 206.685498 85.39418) (xy 206.744463 85.504494) (xy 206.823815 85.601185) (xy 206.920506 85.680537) (xy 207.03082 85.739502) + (xy 207.150518 85.775812) (xy 207.275 85.788072) (xy 208.225 85.788072) (xy 208.349482 85.775812) (xy 208.46918 85.739502) + (xy 208.579494 85.680537) (xy 208.676185 85.601185) (xy 208.755537 85.504494) (xy 208.814502 85.39418) (xy 208.850812 85.274482) + (xy 208.863072 85.15) (xy 208.863072 83.85) (xy 208.850812 83.725518) (xy 208.814502 83.60582) (xy 208.755537 83.495506) + (xy 208.676185 83.398815) (xy 208.579494 83.319463) (xy 208.46918 83.260498) (xy 208.349482 83.224188) (xy 208.225 83.211928) + (xy 207.275 83.211928) (xy 207.150518 83.224188) (xy 207.03082 83.260498) (xy 206.920506 83.319463) (xy 206.823815 83.398815) + (xy 206.744463 83.495506) (xy 206.685498 83.60582) (xy 206.662716 83.680922) (xy 206.58144 83.697089) (xy 206.477843 83.74) + (xy 204.960318 83.74) (xy 204.922995 83.736324) (xy 204.885672 83.74) (xy 204.885663 83.74) (xy 204.77401 83.750997) + (xy 204.638025 83.792247) (xy 204.630749 83.794454) (xy 204.498719 83.865026) (xy 204.416769 83.932281) (xy 204.382995 83.959999) + (xy 204.359197 83.988997) (xy 202.303695 86.0445) (xy 200.41875 86.0445) (xy 200.37625 86.002) (xy 199.227 86.002) + (xy 199.227 86.022) (xy 199.16 86.022) (xy 199.16 85.728) (xy 199.227 85.728) (xy 199.227 85.748) + (xy 200.37625 85.748) (xy 200.535 85.58925) (xy 200.536495 85.485) (xy 200.68224 85.485) (xy 200.84356 85.452911) + (xy 200.995521 85.389967) (xy 201.132281 85.298587) (xy 201.248587 85.182281) (xy 201.339967 85.045521) (xy 201.402911 84.89356) + (xy 201.435 84.73224) (xy 201.435 84.56776) (xy 201.402911 84.40644) (xy 201.339967 84.254479) (xy 201.248587 84.117719) + (xy 201.132281 84.001413) (xy 200.995521 83.910033) (xy 200.891923 83.867122) (xy 200.638803 83.614002) (xy 200.615001 83.584999) + (xy 200.527021 83.512796) (xy 200.525812 83.500518) (xy 200.489502 83.38082) (xy 200.430537 83.270506) (xy 200.351185 83.173815) + (xy 200.254494 83.094463) (xy 200.14418 83.035498) (xy 200.024482 82.999188) (xy 199.9 82.986928) (xy 199.16 82.986928) + (xy 199.16 82.784877) (xy 199.163435 82.75) (xy 199.149727 82.610816) (xy 199.109128 82.47698) (xy 199.0432 82.353637) + (xy 198.954475 82.245525) (xy 198.846363 82.1568) (xy 198.72302 82.090872) (xy 198.589184 82.050273) (xy 198.484877 82.04) + (xy 198.45 82.036565) (xy 198.415123 82.04) (xy 194.984877 82.04) (xy 194.95 82.036565) (xy 194.915123 82.04) + (xy 194.810816 82.050273) (xy 194.67698 82.090872) (xy 194.553637 82.1568) (xy 194.445525 82.245525) (xy 194.3568 82.353637) + (xy 194.290872 82.47698) (xy 194.250273 82.610816) (xy 194.236565 82.75) (xy 194.240001 82.784887) (xy 194.240001 82.986928) + (xy 193.5 82.986928) (xy 193.375518 82.999188) (xy 193.25582 83.035498) (xy 193.145506 83.094463) (xy 193.048815 83.173815) + (xy 192.976691 83.261699) (xy 192.839187 83.303411) (xy 192.685441 83.385589) (xy 192.550683 83.496183) (xy 192.522966 83.529956) + (xy 192.51 83.542922) (xy 192.51 81.964801) (xy 193.891924 80.582878) (xy 193.995521 80.539967) (xy 194.132281 80.448587) + (xy 194.248587 80.332281) (xy 194.339967 80.195521) (xy 194.402911 80.04356) (xy 194.435 79.88224) (xy 194.435 79.71776) + (xy 194.402911 79.55644) (xy 194.342254 79.41) (xy 201.152843 79.41) (xy 201.25644 79.452911) (xy 201.41776 79.485) + (xy 201.58224 79.485) (xy 201.74356 79.452911) (xy 201.895521 79.389967) (xy 202.032281 79.298587) (xy 202.148587 79.182281) + (xy 202.239967 79.045521) (xy 202.302911 78.89356) (xy 202.335 78.73224) (xy 202.335 78.56776) (xy 202.302911 78.40644) + (xy 202.26 78.302843) (xy 202.26 78.058072) (xy 203.55 78.058072) (xy 203.674482 78.045812) (xy 203.79418 78.009502) + (xy 203.904494 77.950537) (xy 204.001185 77.871185) (xy 204.080537 77.774494) (xy 204.139502 77.66418) (xy 204.175812 77.544482) + (xy 204.188072 77.42) (xy 204.188072 75.42) (xy 204.175812 75.295518) (xy 204.139502 75.17582) (xy 204.080537 75.065506) + (xy 204.001185 74.968815) (xy 203.904494 74.889463) (xy 203.79418 74.830498) (xy 203.674482 74.794188) (xy 203.55 74.781928) + (xy 202.430748 74.781928) (xy 202.562953 74.462756) (xy 202.645 74.050279) (xy 202.645 73.629721) (xy 202.562953 73.217244) + (xy 202.402012 72.828698) (xy 202.364985 72.773283) (xy 202.530779 72.704609) (xy 202.790379 72.53115) (xy 203.01115 72.310379) + (xy 203.184609 72.050779) (xy 203.202699 72.007105) (xy 203.260033 72.145521) (xy 203.351413 72.282281) (xy 203.467719 72.398587) + (xy 203.604479 72.489967) (xy 203.75644 72.552911) (xy 203.91776 72.585) (xy 204.08224 72.585) (xy 204.24356 72.552911) + (xy 204.395521 72.489967) (xy 204.532281 72.398587) (xy 204.648587 72.282281) (xy 204.739967 72.145521) (xy 204.802911 71.99356) + (xy 204.835 71.83224) (xy 204.835 71.66776) (xy 204.802911 71.50644) (xy 204.756513 71.394426) (xy 204.749003 71.318172) + (xy 204.705546 71.174911) (xy 204.634974 71.042882) (xy 204.540001 70.927157) (xy 204.511004 70.90336) (xy 202.021645 68.414002) + (xy 201.997842 68.384998) (xy 201.882117 68.290025) (xy 201.750088 68.219453) (xy 201.606827 68.175996) (xy 201.495174 68.164999) + (xy 201.495163 68.164999) (xy 201.463948 68.161924) (xy 201.452911 68.10644) (xy 201.389967 67.954479) (xy 201.298587 67.817719) + (xy 201.182281 67.701413) (xy 201.045521 67.610033) (xy 200.89356 67.547089) (xy 200.73224 67.515) (xy 200.56776 67.515) + (xy 200.417981 67.544793) (xy 200.430537 67.529494) (xy 200.489502 67.41918) (xy 200.525812 67.299482) (xy 200.538072 67.175) + (xy 200.535 66.96075) (xy 200.399115 66.824865) (xy 200.406444 66.827901) (xy 200.567764 66.85999) (xy 200.732244 66.85999) + (xy 200.893564 66.827901) (xy 201.045525 66.764957) (xy 201.182285 66.673577) (xy 201.298591 66.557271) (xy 201.389971 66.420511) + (xy 201.452915 66.26855) (xy 201.485004 66.10723) (xy 201.485004 65.94275) (xy 201.452915 65.78143) (xy 201.389971 65.629469) + (xy 201.298591 65.492709) (xy 201.182285 65.376403) (xy 201.045525 65.285023) (xy 200.941927 65.242112) (xy 200.538072 64.838257) + (xy 200.538072 64.425) (xy 200.525812 64.300518) (xy 200.489502 64.18082) (xy 200.430537 64.070506) (xy 200.351185 63.973815) + (xy 200.254494 63.894463) (xy 200.14418 63.835498) (xy 200.024482 63.799188) (xy 199.9 63.786928) (xy 199.16 63.786928) + (xy 199.16 63.584877) (xy 199.163435 63.55) (xy 199.149727 63.410816) (xy 199.109128 63.27698) (xy 199.101694 63.263072) + (xy 200.7 63.263072) (xy 200.824482 63.250812) (xy 200.94418 63.214502) (xy 201.054494 63.155537) (xy 201.151185 63.076185) + (xy 201.230537 62.979494) (xy 201.289502 62.86918) (xy 201.324735 62.753032) (xy 201.432001 62.665001) (xy 201.455803 62.635998) + (xy 201.911002 62.1808) (xy 201.940001 62.157001) (xy 202.034974 62.041276) (xy 202.105546 61.909247) (xy 202.149003 61.765985) + (xy 202.16 61.654332) (xy 202.16 61.654324) (xy 202.163676 61.617001) (xy 202.161391 61.593799) (xy 202.202911 61.49356) + (xy 202.235 61.33224) (xy 202.235 61.16776) (xy 202.202911 61.00644) (xy 202.139967 60.854479) (xy 202.048587 60.717719) + (xy 201.932281 60.601413) (xy 201.795521 60.510033) (xy 201.64356 60.447089) (xy 201.48224 60.415) (xy 201.31776 60.415) + (xy 201.15644 60.447089) (xy 201.023872 60.502) (xy 199.827 60.502) (xy 199.827 60.522) (xy 199.573 60.522) + (xy 199.573 60.502) (xy 198.22375 60.502) (xy 198.065 60.66075) (xy 198.061928 60.875) (xy 198.074188 60.999482) + (xy 198.110498 61.11918) (xy 198.140947 61.176146) (xy 197.727795 60.762994) (xy 197.703993 60.733991) (xy 197.588268 60.639018) + (xy 197.456239 60.568446) (xy 197.312978 60.524989) (xy 197.201325 60.513992) (xy 197.201314 60.513992) (xy 197.163992 60.510316) + (xy 197.12667 60.513992) (xy 196.938072 60.513992) (xy 196.938072 60.065001) (xy 198.064652 60.065001) (xy 198.065 60.08925) + (xy 198.22375 60.248) (xy 199.573 60.248) (xy 199.573 60.228) (xy 199.827 60.228) (xy 199.827 60.248) + (xy 201.17625 60.248) (xy 201.335 60.08925) (xy 201.338072 59.875) (xy 201.325812 59.750518) (xy 201.306837 59.687964) + (xy 201.836729 59.158072) (xy 203.55 59.158072) (xy 203.674482 59.145812) (xy 203.79418 59.109502) (xy 203.904494 59.050537) + (xy 204.001185 58.971185) (xy 204.080537 58.874494) (xy 204.139502 58.76418) (xy 204.175812 58.644482) (xy 204.188072 58.52) + (xy 204.188072 56.52) (xy 204.175812 56.395518) (xy 204.139502 56.27582) (xy 204.080537 56.165506) (xy 204.001185 56.068815) + (xy 203.904494 55.989463) (xy 203.79418 55.930498) (xy 203.674482 55.894188) (xy 203.55 55.881928) (xy 202.430748 55.881928) + (xy 202.562953 55.562756) (xy 202.645 55.150279) (xy 202.645 54.729721) (xy 202.562953 54.317244) (xy 202.402012 53.928698) + (xy 202.364985 53.873283) (xy 202.530779 53.804609) (xy 202.790379 53.63115) (xy 202.993917 53.427612) (xy 202.997089 53.44356) + (xy 203.060033 53.595521) (xy 203.151413 53.732281) (xy 203.267719 53.848587) (xy 203.404479 53.939967) (xy 203.55644 54.002911) + (xy 203.71776 54.035) (xy 203.88224 54.035) (xy 204.04356 54.002911) (xy 204.195521 53.939967) (xy 204.332281 53.848587) + (xy 204.448587 53.732281) (xy 204.539967 53.595521) (xy 204.602911 53.44356) (xy 204.635 53.28224) (xy 204.635 53.11776) + (xy 204.602911 52.95644) (xy 204.56 52.852843) (xy 204.56 52.570331) (xy 204.563677 52.532998) (xy 204.556491 52.460033) + (xy 204.549003 52.384012) (xy 204.505546 52.240751) (xy 204.434974 52.108722) (xy 204.340001 51.992997) (xy 204.311004 51.9692) + (xy 203.101803 50.76) (xy 204.503874 50.76) (xy 204.509815 50.761802) (xy 204.6588 50.776476) (xy 204.807786 50.761802) + (xy 204.813727 50.76) (xy 204.962678 50.76) (xy 205 50.763676) (xy 205.037322 50.76) (xy 205.037333 50.76) + (xy 205.148986 50.749003) (xy 205.292247 50.705546) (xy 205.424276 50.634974) (xy 205.540001 50.540001) (xy 205.563804 50.510997) + (xy 206.77865 49.296151) (xy 206.823815 49.351185) (xy 206.920506 49.430537) (xy 207.03082 49.489502) (xy 207.150518 49.525812) + (xy 207.275 49.538072) (xy 208.225 49.538072) (xy 208.349482 49.525812) (xy 208.46918 49.489502) (xy 208.579494 49.430537) + (xy 208.676185 49.351185) (xy 208.755537 49.254494) (xy 208.814502 49.14418) (xy 208.850812 49.024482) (xy 208.863072 48.9) + (xy 208.863072 47.6) (xy 208.850812 47.475518) (xy 208.840614 47.4419) (xy 209.280778 47.4419) (xy 209.3181 47.445576) + (xy 209.355422 47.4419) (xy 209.355433 47.4419) (xy 209.467086 47.430903) (xy 209.610347 47.387446) (xy 209.742376 47.316874) + (xy 209.858101 47.221901) (xy 209.881904 47.192897) (xy 210.091922 46.982879) (xy 210.195521 46.939967) (xy 210.332281 46.848587) + (xy 210.448587 46.732281) (xy 210.536199 46.60116) + ) + ) + (filled_polygon + (pts + (xy 148.886928 100.99) (xy 148.899188 101.114482) (xy 148.935498 101.23418) (xy 148.994463 101.344494) (xy 149.073815 101.441185) + (xy 149.170506 101.520537) (xy 149.28082 101.579502) (xy 149.400518 101.615812) (xy 149.525 101.628072) (xy 150.213271 101.628072) + (xy 150.840001 102.254803) (xy 150.840001 103.131928) (xy 150.45 103.131928) (xy 150.325518 103.144188) (xy 150.20582 103.180498) + (xy 150.095506 103.239463) (xy 149.998815 103.318815) (xy 149.919463 103.415506) (xy 149.860498 103.52582) (xy 149.824188 103.645518) + (xy 149.811928 103.77) (xy 149.811928 105.77) (xy 149.824188 105.894482) (xy 149.860498 106.01418) (xy 149.919463 106.124494) + (xy 149.998815 106.221185) (xy 150.095506 106.300537) (xy 150.0962 106.300908) (xy 150.065 106.45776) (xy 150.065 106.62224) + (xy 150.097089 106.78356) (xy 150.160033 106.935521) (xy 150.251413 107.072281) (xy 150.367719 107.188587) (xy 150.504479 107.279967) + (xy 150.65644 107.342911) (xy 150.81776 107.375) (xy 150.98224 107.375) (xy 151.14356 107.342911) (xy 151.295521 107.279967) + (xy 151.432281 107.188587) (xy 151.548587 107.072281) (xy 151.639967 106.935521) (xy 151.702911 106.78356) (xy 151.735 106.62224) + (xy 151.735 106.45776) (xy 151.725116 106.408072) (xy 152.75 106.408072) (xy 152.874482 106.395812) (xy 152.99418 106.359502) + (xy 153.104494 106.300537) (xy 153.201185 106.221185) (xy 153.228525 106.187872) (xy 153.429017 106.388364) (xy 153.778698 106.622013) + (xy 153.994302 106.711319) (xy 153.925 107.059721) (xy 153.925 107.480279) (xy 154.007047 107.892756) (xy 154.167988 108.281302) + (xy 154.401637 108.630983) (xy 154.699017 108.928363) (xy 155.048698 109.162012) (xy 155.437244 109.322953) (xy 155.849721 109.405) + (xy 156.270279 109.405) (xy 156.682756 109.322953) (xy 157.071302 109.162012) (xy 157.420983 108.928363) (xy 157.718363 108.630983) + (xy 157.952012 108.281302) (xy 158.112953 107.892756) (xy 158.195 107.480279) (xy 158.195 107.059721) (xy 158.112953 106.647244) + (xy 157.952012 106.258698) (xy 157.718363 105.909017) (xy 157.420983 105.611637) (xy 157.071302 105.377988) (xy 156.855698 105.288682) + (xy 156.925 104.94028) (xy 156.925 104.519722) (xy 156.873463 104.260627) (xy 156.888412 104.275576) (xy 157.328175 104.569417) + (xy 157.816814 104.771817) (xy 158.335551 104.875) (xy 158.864449 104.875) (xy 159.383186 104.771817) (xy 159.871825 104.569417) + (xy 160.311588 104.275576) (xy 160.326537 104.260627) (xy 160.275 104.519721) (xy 160.275 104.940279) (xy 160.344302 105.288682) + (xy 160.128698 105.377988) (xy 159.779017 105.611637) (xy 159.481637 105.909017) (xy 159.247988 106.258698) (xy 159.087047 106.647244) + (xy 159.005 107.059721) (xy 159.005 107.480279) (xy 159.087047 107.892756) (xy 159.247988 108.281302) (xy 159.481637 108.630983) + (xy 159.779017 108.928363) (xy 160.128698 109.162012) (xy 160.517244 109.322953) (xy 160.929721 109.405) (xy 161.350279 109.405) + (xy 161.762756 109.322953) (xy 162.151302 109.162012) (xy 162.500983 108.928363) (xy 162.640001 108.789345) (xy 162.64 109.192843) + (xy 162.597089 109.29644) (xy 162.565 109.45776) (xy 162.565 109.62224) (xy 162.597089 109.78356) (xy 162.660033 109.935521) + (xy 162.751413 110.072281) (xy 162.867719 110.188587) (xy 163.004479 110.279967) (xy 163.15644 110.342911) (xy 163.31776 110.375) + (xy 163.48224 110.375) (xy 163.64356 110.342911) (xy 163.795521 110.279967) (xy 163.932281 110.188587) (xy 164.048587 110.072281) + (xy 164.139967 109.935521) (xy 164.202911 109.78356) (xy 164.235 109.62224) (xy 164.235 109.45776) (xy 164.202911 109.29644) + (xy 164.16 109.192843) (xy 164.16 108.948072) (xy 165.45 108.948072) (xy 165.539991 108.939209) (xy 165.539991 110.98001) + (xy 154.878455 110.98001) (xy 154.834989 110.975729) (xy 154.791523 110.98001) (xy 154.791513 110.98001) (xy 154.6615 110.992815) + (xy 154.494677 111.043421) (xy 154.340931 111.125599) (xy 154.322186 111.140983) (xy 154.239943 111.208478) (xy 154.239941 111.20848) + (xy 154.206173 111.236193) (xy 154.17846 111.269961) (xy 153.75491 111.693511) (xy 153.76 111.641833) (xy 153.76 111.641825) + (xy 153.763676 111.6045) (xy 153.76 111.567175) (xy 153.76 109.387157) (xy 153.802911 109.28356) (xy 153.835 109.12224) + (xy 153.835 108.95776) (xy 153.802911 108.79644) (xy 153.739967 108.644479) (xy 153.648587 108.507719) (xy 153.532281 108.391413) + (xy 153.395521 108.300033) (xy 153.24356 108.237089) (xy 153.08224 108.205) (xy 152.91776 108.205) (xy 152.75644 108.237089) + (xy 152.604479 108.300033) (xy 152.467719 108.391413) (xy 152.351413 108.507719) (xy 152.260033 108.644479) (xy 152.197089 108.79644) + (xy 152.165 108.95776) (xy 152.165 109.12224) (xy 152.197089 109.28356) (xy 152.24 109.387157) (xy 152.240001 111.289697) + (xy 149.837099 113.6926) (xy 145.613382 113.6926) (xy 147.323009 111.982974) (xy 147.352001 111.959181) (xy 147.375795 111.930188) + (xy 147.375799 111.930184) (xy 147.445279 111.845521) (xy 147.446974 111.843456) (xy 147.517546 111.711427) (xy 147.561003 111.568166) + (xy 147.572 111.456513) (xy 147.572 111.456504) (xy 147.575676 111.419181) (xy 147.572 111.381858) (xy 147.572 101.978301) + (xy 148.31912 101.231182) (xy 148.424276 101.174974) (xy 148.540001 101.080001) (xy 148.563804 101.050997) (xy 148.886928 100.727873) + ) + ) + (filled_polygon + (pts + (xy 129.886928 105.6) (xy 129.899188 105.724482) (xy 129.935498 105.84418) (xy 129.994463 105.954494) (xy 130.073815 106.051185) + (xy 130.170506 106.130537) (xy 130.28082 106.189502) (xy 130.376794 106.218615) (xy 130.431174 106.284877) (xy 130.46 106.320001) + (xy 130.488998 106.343799) (xy 130.711928 106.566729) (xy 130.711928 108.28) (xy 130.724188 108.404482) (xy 130.760498 108.52418) + (xy 130.819463 108.634494) (xy 130.898815 108.731185) (xy 130.979066 108.797045) (xy 130.965 108.86776) (xy 130.965 109.03224) + (xy 130.997089 109.19356) (xy 131.060033 109.345521) (xy 131.151413 109.482281) (xy 131.267719 109.598587) (xy 131.404479 109.689967) + (xy 131.55644 109.752911) (xy 131.71776 109.785) (xy 131.88224 109.785) (xy 132.04356 109.752911) (xy 132.195521 109.689967) + (xy 132.332281 109.598587) (xy 132.448587 109.482281) (xy 132.539967 109.345521) (xy 132.602911 109.19356) (xy 132.635 109.03224) + (xy 132.635 108.918072) (xy 133.65 108.918072) (xy 133.774482 108.905812) (xy 133.89418 108.869502) (xy 134.004494 108.810537) + (xy 134.101185 108.731185) (xy 134.128525 108.697872) (xy 134.329017 108.898364) (xy 134.678698 109.132013) (xy 134.894302 109.221319) + (xy 134.825 109.569721) (xy 134.825 109.990279) (xy 134.907047 110.402756) (xy 135.067988 110.791302) (xy 135.301637 111.140983) + (xy 135.599017 111.438363) (xy 135.948698 111.672012) (xy 136.337244 111.832953) (xy 136.749721 111.915) (xy 137.170279 111.915) + (xy 137.582756 111.832953) (xy 137.971302 111.672012) (xy 138.320983 111.438363) (xy 138.618363 111.140983) (xy 138.852012 110.791302) + (xy 139.012953 110.402756) (xy 139.095 109.990279) (xy 139.095 109.569721) (xy 139.012953 109.157244) (xy 138.852012 108.768698) + (xy 138.618363 108.419017) (xy 138.320983 108.121637) (xy 137.971302 107.887988) (xy 137.755698 107.798682) (xy 137.825 107.45028) + (xy 137.825 107.029722) (xy 137.773463 106.770627) (xy 137.788412 106.785576) (xy 138.228175 107.079417) (xy 138.716814 107.281817) + (xy 139.235551 107.385) (xy 139.764449 107.385) (xy 140.283186 107.281817) (xy 140.771825 107.079417) (xy 141.211588 106.785576) + (xy 141.226537 106.770627) (xy 141.175 107.029721) (xy 141.175 107.450279) (xy 141.244302 107.798682) (xy 141.028698 107.887988) + (xy 140.679017 108.121637) (xy 140.381637 108.419017) (xy 140.147988 108.768698) (xy 139.987047 109.157244) (xy 139.905 109.569721) + (xy 139.905 109.990279) (xy 139.987047 110.402756) (xy 140.147988 110.791302) (xy 140.381637 111.140983) (xy 140.679017 111.438363) + (xy 141.028698 111.672012) (xy 141.417244 111.832953) (xy 141.829721 111.915) (xy 142.250279 111.915) (xy 142.662756 111.832953) + (xy 143.051302 111.672012) (xy 143.400983 111.438363) (xy 143.54 111.299346) (xy 143.54 111.602843) (xy 143.497089 111.70644) + (xy 143.465 111.86776) (xy 143.465 112.03224) (xy 143.497089 112.19356) (xy 143.560033 112.345521) (xy 143.651413 112.482281) + (xy 143.767719 112.598587) (xy 143.904479 112.689967) (xy 144.05644 112.752911) (xy 144.21776 112.785) (xy 144.371378 112.785) + (xy 143.913789 113.24259) (xy 135.727933 113.24259) (xy 135.69061 113.238914) (xy 135.653287 113.24259) (xy 135.653277 113.24259) + (xy 135.541624 113.253587) (xy 135.398363 113.297044) (xy 135.266334 113.367616) (xy 135.150609 113.462589) (xy 135.126806 113.491593) + (xy 135.011811 113.606588) (xy 131.618213 113.606588) (xy 133.102736 112.122066) (xy 133.16776 112.135) (xy 133.33224 112.135) + (xy 133.49356 112.102911) (xy 133.645521 112.039967) (xy 133.782281 111.948587) (xy 133.898587 111.832281) (xy 133.989967 111.695521) + (xy 134.052911 111.54356) (xy 134.085 111.38224) (xy 134.085 111.21776) (xy 134.052911 111.05644) (xy 133.989967 110.904479) + (xy 133.898587 110.767719) (xy 133.782281 110.651413) (xy 133.645521 110.560033) (xy 133.49356 110.497089) (xy 133.33224 110.465) + (xy 133.16776 110.465) (xy 133.00644 110.497089) (xy 132.902843 110.54) (xy 132.887322 110.54) (xy 132.849999 110.536324) + (xy 132.812677 110.54) (xy 132.812667 110.54) (xy 132.701014 110.550997) (xy 132.557753 110.594454) (xy 132.425724 110.665026) + (xy 132.309999 110.759999) (xy 132.286196 110.789003) (xy 132.239003 110.836196) (xy 132.238997 110.836201) (xy 130.26255 112.812649) + (xy 130.233546 112.836452) (xy 130.186192 112.894154) (xy 130.138573 112.952177) (xy 130.08925 113.044454) (xy 130.068001 113.084207) + (xy 130.024544 113.227468) (xy 130.021007 113.26338) (xy 129.970636 113.384987) (xy 129.938547 113.546307) (xy 129.938547 113.606588) + (xy 129.71506 113.606588) (xy 129.715105 113.60644) (xy 129.753403 113.480186) (xy 129.7644 113.368533) (xy 129.7644 113.368524) + (xy 129.768076 113.331201) (xy 129.7644 113.293878) (xy 129.7644 105.460401) (xy 129.886928 105.337873) + ) + ) + (filled_polygon + (pts + (xy 220.515009 105.737686) (xy 220.511333 105.775009) (xy 220.515009 105.812331) (xy 220.515009 105.812341) (xy 220.526006 105.923994) + (xy 220.56071 106.038399) (xy 220.569463 106.067255) (xy 220.640035 106.199285) (xy 220.677105 106.244454) (xy 220.735008 106.31501) + (xy 220.764012 106.338813) (xy 222.090001 107.664803) (xy 222.090001 108.532799) (xy 222.06115 108.489621) (xy 221.840379 108.26885) + (xy 221.580779 108.095391) (xy 221.292327 107.975911) (xy 220.986109 107.915) (xy 220.673891 107.915) (xy 220.367673 107.975911) + (xy 220.273303 108.015) (xy 220.10374 108.015) (xy 219.816842 108.072068) (xy 219.546589 108.18401) (xy 219.303368 108.346525) + (xy 219.096525 108.553368) (xy 218.93401 108.796589) (xy 218.822068 109.066842) (xy 218.765 109.35374) (xy 218.765 109.64626) + (xy 218.822068 109.933158) (xy 218.857988 110.019876) (xy 218.548698 110.147988) (xy 218.326252 110.296622) (xy 218.331817 110.283186) + (xy 218.435 109.764449) (xy 218.435 109.235551) (xy 218.331817 108.716814) (xy 218.129417 108.228175) (xy 217.835576 107.788412) + (xy 217.461588 107.414424) (xy 217.021825 107.120583) (xy 216.5762 106.936) (xy 217.465123 106.936) (xy 217.5 106.939435) + (xy 217.534877 106.936) (xy 217.581076 106.93145) (xy 217.639184 106.925727) (xy 217.77302 106.885128) (xy 217.896363 106.8192) + (xy 218.004475 106.730475) (xy 218.0932 106.622363) (xy 218.159128 106.49902) (xy 218.199727 106.365184) (xy 218.21 106.260877) + (xy 218.21 106.260876) (xy 218.213435 106.226) (xy 218.21 106.191123) (xy 218.21 106.01) (xy 218.277002 106.01) + (xy 218.277002 105.851252) (xy 218.43575 106.01) (xy 218.95 106.013072) (xy 219.074482 106.000812) (xy 219.19418 105.964502) + (xy 219.304494 105.905537) (xy 219.401185 105.826185) (xy 219.480537 105.729494) (xy 219.539502 105.61918) (xy 219.575812 105.499482) + (xy 219.588072 105.375) (xy 219.585 105.16075) (xy 219.42625 105.002) (xy 218.277 105.002) (xy 218.277 105.022) + (xy 218.21 105.022) (xy 218.21 104.728) (xy 218.277 104.728) (xy 218.277 104.748) (xy 219.42625 104.748) + (xy 219.585 104.58925) (xy 219.588072 104.375) (xy 219.575812 104.250518) (xy 219.539502 104.13082) (xy 219.480537 104.020506) + (xy 219.463708 104) (xy 219.480537 103.979494) (xy 219.490957 103.96) (xy 219.50724 103.96) (xy 219.66856 103.927911) + (xy 219.820521 103.864967) (xy 219.957281 103.773587) (xy 220.073587 103.657281) (xy 220.083447 103.642525) (xy 220.088803 103.635998) + (xy 220.361002 103.3638) (xy 220.390001 103.340001) (xy 220.484974 103.224276) (xy 220.51501 103.168084) + ) + ) + (filled_polygon + (pts + (xy 187.74 97.314802) (xy 187.740001 103.757317) (xy 187.670506 103.794463) (xy 187.573815 103.873815) (xy 187.494463 103.970506) + (xy 187.435498 104.08082) (xy 187.399188 104.200518) (xy 187.386928 104.325) (xy 187.386928 105.625) (xy 187.399188 105.749482) + (xy 187.435498 105.86918) (xy 187.494463 105.979494) (xy 187.573815 106.076185) (xy 187.670506 106.155537) (xy 187.78082 106.214502) + (xy 187.900518 106.250812) (xy 188.025 106.263072) (xy 188.650908 106.263072) (xy 188.702317 106.340011) (xy 188.252309 106.340011) + (xy 188.214986 106.336335) (xy 188.177663 106.340011) (xy 188.177654 106.340011) (xy 188.066001 106.351008) (xy 187.92274 106.394465) + (xy 187.790711 106.465037) (xy 187.674986 106.56001) (xy 187.651188 106.589008) (xy 186.2054 108.034797) (xy 186.2054 100.763672) + (xy 186.26108 100.746782) (xy 186.371394 100.687817) (xy 186.468085 100.608465) (xy 186.547437 100.511774) (xy 186.606402 100.40146) + (xy 186.642712 100.281762) (xy 186.654972 100.15728) (xy 186.654972 99.52228) (xy 186.642712 99.397798) (xy 186.624997 99.3394) + (xy 186.642712 99.281002) (xy 186.654972 99.15652) (xy 186.654972 98.52152) (xy 186.642712 98.397038) (xy 186.606402 98.27734) + (xy 186.547437 98.167026) (xy 186.468085 98.070335) (xy 186.371394 97.990983) (xy 186.26108 97.932018) (xy 186.234999 97.924106) + (xy 186.234999 96.710558) (xy 186.27791 96.606961) (xy 186.309999 96.445641) (xy 186.309999 96.281161) (xy 186.27791 96.119841) + (xy 186.234999 96.016244) (xy 186.234999 95.8098) + ) + ) + (filled_polygon + (pts + (xy 127.115 102.268079) (xy 127.115 106.692528) (xy 127.104089 106.637673) (xy 126.984609 106.349221) (xy 126.81115 106.089621) + (xy 126.590379 105.86885) (xy 126.330779 105.695391) (xy 126.042327 105.575911) (xy 125.736109 105.515) (xy 125.423891 105.515) + (xy 125.117673 105.575911) (xy 125.023303 105.615) (xy 124.85374 105.615) (xy 124.566842 105.672068) (xy 124.296589 105.78401) + (xy 124.053368 105.946525) (xy 123.846525 106.153368) (xy 123.68401 106.396589) (xy 123.572068 106.666842) (xy 123.515 106.95374) + (xy 123.515 107.24626) (xy 123.572068 107.533158) (xy 123.607988 107.619876) (xy 123.298698 107.747988) (xy 123.076252 107.896622) + (xy 123.081817 107.883186) (xy 123.185 107.364449) (xy 123.185 106.835551) (xy 123.081817 106.316814) (xy 122.879417 105.828175) + (xy 122.585576 105.388412) (xy 122.211588 105.014424) (xy 121.771825 104.720583) (xy 121.384142 104.56) (xy 122.215123 104.56) + (xy 122.25 104.563435) (xy 122.284877 104.56) (xy 122.389184 104.549727) (xy 122.52302 104.509128) (xy 122.646363 104.4432) + (xy 122.754475 104.354475) (xy 122.8432 104.246363) (xy 122.909128 104.12302) (xy 122.949727 103.989184) (xy 122.963435 103.85) + (xy 122.96 103.815123) (xy 122.96 103.61) (xy 123.027002 103.61) (xy 123.027002 103.451252) (xy 123.18575 103.61) + (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) (xy 124.151185 103.426185) + (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) (xy 124.335 102.76075) + (xy 124.17625 102.602) (xy 123.027 102.602) (xy 123.027 102.622) (xy 122.96 102.622) (xy 122.96 102.328) + (xy 123.027 102.328) (xy 123.027 102.348) (xy 124.17625 102.348) (xy 124.218867 102.305383) (xy 124.36776 102.335) + (xy 124.53224 102.335) (xy 124.69356 102.302911) (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) + (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) + (xy 125.207568 101.146971) (xy 125.199003 101.060014) (xy 125.155546 100.916753) (xy 125.084974 100.784724) (xy 124.990001 100.668999) + (xy 124.960998 100.645197) (xy 124.529804 100.214003) (xy 124.506001 100.184999) (xy 124.390276 100.090026) (xy 124.309538 100.04687) + (xy 124.289502 99.98082) (xy 124.230537 99.870506) (xy 124.151185 99.773815) (xy 124.054494 99.694463) (xy 123.94418 99.635498) + (xy 123.824482 99.599188) (xy 123.7 99.586928) (xy 122.96 99.586928) (xy 122.96 99.384877) (xy 122.963435 99.35) + (xy 122.957033 99.285) (xy 124.131922 99.285) + ) + ) + (filled_polygon + (pts + (xy 116.661928 102.369729) (xy 116.661928 102.975) (xy 116.674188 103.099482) (xy 116.710498 103.21918) (xy 116.769463 103.329494) + (xy 116.848815 103.426185) (xy 116.945506 103.505537) (xy 117.05582 103.564502) (xy 117.175518 103.600812) (xy 117.3 103.613072) + (xy 118.04 103.613072) (xy 118.04 103.815123) (xy 118.036565 103.85) (xy 118.050273 103.989184) (xy 118.090872 104.12302) + (xy 118.1568 104.246363) (xy 118.245525 104.354475) (xy 118.337726 104.430142) (xy 118.353637 104.4432) (xy 118.47698 104.509128) + (xy 118.610816 104.549727) (xy 118.75 104.563435) (xy 118.784877 104.56) (xy 119.615858 104.56) (xy 119.228175 104.720583) + (xy 118.788412 105.014424) (xy 118.414424 105.388412) (xy 118.120583 105.828175) (xy 117.935001 106.276212) (xy 117.935001 105.511922) + (xy 117.938677 105.474599) (xy 117.935001 105.437276) (xy 117.935001 105.437267) (xy 117.924004 105.325614) (xy 117.880547 105.182353) + (xy 117.809975 105.050324) (xy 117.767843 104.998986) (xy 117.7388 104.963596) (xy 117.738796 104.963592) (xy 117.715002 104.934599) + (xy 117.68601 104.910806) (xy 116.5205 103.745298) (xy 116.5205 102.228301) + ) + ) + (filled_polygon + (pts + (xy 203.129712 100.870692) (xy 203.354727 101.413928) (xy 203.681399 101.902826) (xy 204.097174 102.318601) (xy 204.586072 102.645273) + (xy 205.129308 102.870288) (xy 205.706003 102.985) (xy 206.273805 102.985) (xy 206.255088 103.030187) (xy 206.222999 103.191507) + (xy 206.222999 103.278393) (xy 206.195521 103.260033) (xy 206.04356 103.197089) (xy 205.88224 103.165) (xy 205.71776 103.165) + (xy 205.55644 103.197089) (xy 205.404479 103.260033) (xy 205.267719 103.351413) (xy 205.151413 103.467719) (xy 205.060033 103.604479) + (xy 205.017122 103.708076) (xy 204.089002 104.636197) (xy 204.088997 104.636201) (xy 202.835189 105.89001) (xy 200.273414 105.89001) + (xy 200.351185 105.826185) (xy 200.430537 105.729494) (xy 200.489502 105.61918) (xy 200.525812 105.499482) (xy 200.538072 105.375) + (xy 200.535 105.16075) (xy 200.37625 105.002) (xy 199.227 105.002) (xy 199.227 105.022) (xy 199.16 105.022) + (xy 199.16 104.728) (xy 199.227 104.728) (xy 199.227 104.748) (xy 200.37625 104.748) (xy 200.535 104.58925) + (xy 200.535438 104.558679) (xy 200.66776 104.585) (xy 200.83224 104.585) (xy 200.99356 104.552911) (xy 201.145521 104.489967) + (xy 201.282281 104.398587) (xy 201.398587 104.282281) (xy 201.489967 104.145521) (xy 201.552911 103.99356) (xy 201.585 103.83224) + (xy 201.585 103.66776) (xy 201.552911 103.50644) (xy 201.489967 103.354479) (xy 201.398587 103.217719) (xy 201.282281 103.101413) + (xy 201.145521 103.010033) (xy 201.041924 102.967122) (xy 200.688803 102.614002) (xy 200.665001 102.584999) (xy 200.549276 102.490026) + (xy 200.517473 102.473026) (xy 200.489502 102.38082) (xy 200.430537 102.270506) (xy 200.351185 102.173815) (xy 200.254494 102.094463) + (xy 200.236785 102.084997) (xy 202.006532 102.084997) (xy 202.050001 102.089278) (xy 202.09347 102.084997) (xy 202.093478 102.084997) + (xy 202.223491 102.072192) (xy 202.390314 102.021586) (xy 202.54406 101.939408) (xy 202.678818 101.828814) (xy 202.706535 101.795041) + (xy 202.906532 101.595044) (xy 202.98941 101.494057) (xy 203.071588 101.340311) (xy 203.122194 101.173489) (xy 203.139281 100.999999) + (xy 203.12344 100.839161) + ) + ) + (filled_polygon + (pts + (xy 173.869463 100.929494) (xy 173.948815 101.026185) (xy 174.045506 101.105537) (xy 174.15582 101.164502) (xy 174.275518 101.200812) + (xy 174.4 101.213072) (xy 175.14 101.213072) (xy 175.14 101.515123) (xy 175.136565 101.55) (xy 175.150273 101.689184) + (xy 175.190872 101.82302) (xy 175.2568 101.946363) (xy 175.345525 102.054475) (xy 175.409811 102.107233) (xy 175.453637 102.1432) + (xy 175.57698 102.209128) (xy 175.710816 102.249727) (xy 175.85 102.263435) (xy 175.884877 102.26) (xy 176.474436 102.26) + (xy 176.328175 102.320583) (xy 175.888412 102.614424) (xy 175.514424 102.988412) (xy 175.220583 103.428175) (xy 175.018183 103.916814) + (xy 174.915 104.435551) (xy 174.915 104.964449) (xy 175.018183 105.483186) (xy 175.023749 105.496623) (xy 174.801302 105.347989) + (xy 174.492012 105.219877) (xy 174.527932 105.133158) (xy 174.585 104.84626) (xy 174.585 104.55374) (xy 174.527932 104.266842) + (xy 174.41599 103.996589) (xy 174.253475 103.753368) (xy 174.046632 103.546525) (xy 173.803411 103.38401) (xy 173.533158 103.272068) + (xy 173.24626 103.215) (xy 173.076697 103.215) (xy 172.982327 103.175911) (xy 172.676109 103.115) (xy 172.363891 103.115) + (xy 172.057673 103.175911) (xy 171.769221 103.295391) (xy 171.509621 103.46885) (xy 171.28885 103.689621) (xy 171.115391 103.949221) + (xy 170.995911 104.237673) (xy 170.936442 104.53664) (xy 170.363072 103.963271) (xy 170.363072 103.66) (xy 170.775864 103.66) + (xy 170.813186 103.663676) (xy 170.850508 103.66) (xy 170.850519 103.66) (xy 170.962172 103.649003) (xy 171.105433 103.605546) + (xy 171.237462 103.534974) (xy 171.353187 103.440001) (xy 171.37699 103.410997) (xy 173.865642 100.922346) + ) + ) + (filled_polygon + (pts + (xy 181.64 92.602843) (xy 181.597089 92.70644) (xy 181.565 92.86776) (xy 181.565 93.03224) (xy 181.597089 93.19356) + (xy 181.660033 93.345521) (xy 181.751413 93.482281) (xy 181.867719 93.598587) (xy 182.004479 93.689967) (xy 182.108078 93.732879) + (xy 183.195002 94.819804) (xy 183.195001 103.197729) (xy 183.142327 103.175911) (xy 182.836109 103.115) (xy 182.523891 103.115) + (xy 182.217673 103.175911) (xy 182.123303 103.215) (xy 181.95374 103.215) (xy 181.666842 103.272068) (xy 181.396589 103.38401) + (xy 181.153368 103.546525) (xy 180.946525 103.753368) (xy 180.78401 103.996589) (xy 180.672068 104.266842) (xy 180.615 104.55374) + (xy 180.615 104.84626) (xy 180.672068 105.133158) (xy 180.707988 105.219876) (xy 180.398698 105.347988) (xy 180.176252 105.496622) + (xy 180.181817 105.483186) (xy 180.285 104.964449) (xy 180.285 104.435551) (xy 180.181817 103.916814) (xy 179.979417 103.428175) + (xy 179.685576 102.988412) (xy 179.311588 102.614424) (xy 178.871825 102.320583) (xy 178.725564 102.26) (xy 179.315123 102.26) + (xy 179.35 102.263435) (xy 179.384877 102.26) (xy 179.457932 102.252805) (xy 179.489184 102.249727) (xy 179.62302 102.209128) + (xy 179.746363 102.1432) (xy 179.854475 102.054475) (xy 179.9432 101.946363) (xy 180.009128 101.82302) (xy 180.049727 101.689184) + (xy 180.06 101.584877) (xy 180.06 101.584876) (xy 180.063435 101.55) (xy 180.06 101.515123) (xy 180.06 101.21) + (xy 180.127002 101.21) (xy 180.127002 101.051252) (xy 180.28575 101.21) (xy 180.8 101.213072) (xy 180.924482 101.200812) + (xy 181.04418 101.164502) (xy 181.154494 101.105537) (xy 181.251185 101.026185) (xy 181.330537 100.929494) (xy 181.389502 100.81918) + (xy 181.425812 100.699482) (xy 181.438072 100.575) (xy 181.435 100.36075) (xy 181.27625 100.202) (xy 180.127 100.202) + (xy 180.127 100.222) (xy 180.06 100.222) (xy 180.06 99.928) (xy 180.127 99.928) (xy 180.127 99.948) + (xy 181.27625 99.948) (xy 181.435 99.78925) (xy 181.436074 99.714346) (xy 181.49356 99.702911) (xy 181.645521 99.639967) + (xy 181.782281 99.548587) (xy 181.898587 99.432281) (xy 181.989967 99.295521) (xy 182.052911 99.14356) (xy 182.085 98.98224) + (xy 182.085 98.81776) (xy 182.052911 98.65644) (xy 182.012218 98.558199) (xy 182.01 98.535676) (xy 182.01 98.535668) + (xy 181.999003 98.424015) (xy 181.955546 98.280753) (xy 181.884974 98.148724) (xy 181.790001 98.032999) (xy 181.760997 98.009196) + (xy 181.602304 97.850503) (xy 181.578501 97.821499) (xy 181.462776 97.726526) (xy 181.426462 97.707115) (xy 181.425812 97.700518) + (xy 181.389502 97.58082) (xy 181.330537 97.470506) (xy 181.251185 97.373815) (xy 181.154494 97.294463) (xy 181.04418 97.235498) + (xy 180.924482 97.199188) (xy 180.8 97.186928) (xy 180.76 97.186928) (xy 180.76 96.537322) (xy 180.763676 96.499999) + (xy 180.76 96.462676) (xy 180.76 96.462667) (xy 180.749003 96.351014) (xy 180.705546 96.207753) (xy 180.634974 96.075724) + (xy 180.540001 95.959999) (xy 180.511003 95.936201) (xy 179.074999 94.500198) (xy 179.074999 92.536132) (xy 179.128698 92.572012) + (xy 179.517244 92.732953) (xy 179.929721 92.815) (xy 180.350279 92.815) (xy 180.762756 92.732953) (xy 181.151302 92.572012) + (xy 181.500983 92.338363) (xy 181.640001 92.199345) + ) + ) + (filled_polygon + (pts + (xy 143.215 92.60723) (xy 143.247089 92.76855) (xy 143.310033 92.920511) (xy 143.401413 93.057271) (xy 143.517719 93.173577) + (xy 143.654479 93.264957) (xy 143.758078 93.307869) (xy 145.095002 94.644794) (xy 145.095001 103.197729) (xy 145.042327 103.175911) + (xy 144.736109 103.115) (xy 144.423891 103.115) (xy 144.117673 103.175911) (xy 144.023303 103.215) (xy 143.85374 103.215) + (xy 143.566842 103.272068) (xy 143.296589 103.38401) (xy 143.053368 103.546525) (xy 142.846525 103.753368) (xy 142.68401 103.996589) + (xy 142.572068 104.266842) (xy 142.515 104.55374) (xy 142.515 104.84626) (xy 142.572068 105.133158) (xy 142.607988 105.219876) + (xy 142.298698 105.347988) (xy 142.076252 105.496622) (xy 142.081817 105.483186) (xy 142.185 104.964449) (xy 142.185 104.435551) + (xy 142.081817 103.916814) (xy 141.879417 103.428175) (xy 141.585576 102.988412) (xy 141.211588 102.614424) (xy 140.771825 102.320583) + (xy 140.625564 102.26) (xy 141.215123 102.26) (xy 141.25 102.263435) (xy 141.284877 102.26) (xy 141.357932 102.252805) + (xy 141.389184 102.249727) (xy 141.52302 102.209128) (xy 141.646363 102.1432) (xy 141.754475 102.054475) (xy 141.8432 101.946363) + (xy 141.909128 101.82302) (xy 141.949727 101.689184) (xy 141.96 101.584877) (xy 141.96 101.584876) (xy 141.963435 101.55) + (xy 141.96 101.515123) (xy 141.96 101.21) (xy 142.027002 101.21) (xy 142.027002 101.051252) (xy 142.18575 101.21) + (xy 142.7 101.213072) (xy 142.824482 101.200812) (xy 142.94418 101.164502) (xy 143.054494 101.105537) (xy 143.151185 101.026185) + (xy 143.230537 100.929494) (xy 143.289502 100.81918) (xy 143.325812 100.699482) (xy 143.338072 100.575) (xy 143.335 100.36075) + (xy 143.17625 100.202) (xy 142.027 100.202) (xy 142.027 100.222) (xy 141.96 100.222) (xy 141.96 99.928) + (xy 142.027 99.928) (xy 142.027 99.948) (xy 143.17625 99.948) (xy 143.296264 99.827986) (xy 143.35644 99.852911) + (xy 143.51776 99.885) (xy 143.68224 99.885) (xy 143.84356 99.852911) (xy 143.995521 99.789967) (xy 144.132281 99.698587) + (xy 144.248587 99.582281) (xy 144.339967 99.445521) (xy 144.402911 99.29356) (xy 144.435 99.13224) (xy 144.435 98.96776) + (xy 144.402911 98.80644) (xy 144.340821 98.65654) (xy 144.305546 98.540253) (xy 144.234974 98.408224) (xy 144.140001 98.292499) + (xy 144.111004 98.268702) (xy 143.556303 97.714002) (xy 143.532501 97.684999) (xy 143.416776 97.590026) (xy 143.284747 97.519454) + (xy 143.251273 97.5093) (xy 143.230537 97.470506) (xy 143.151185 97.373815) (xy 143.054494 97.294463) (xy 142.94418 97.235498) + (xy 142.824482 97.199188) (xy 142.71 97.187913) (xy 142.71 96.587323) (xy 142.713676 96.55) (xy 142.71 96.512677) + (xy 142.71 96.512667) (xy 142.699003 96.401014) (xy 142.655546 96.257753) (xy 142.616016 96.183799) (xy 142.584974 96.125723) + (xy 142.513799 96.038997) (xy 142.490001 96.009999) (xy 142.461004 95.986202) (xy 140.974999 94.500198) (xy 140.974999 92.536132) + (xy 141.028698 92.572012) (xy 141.417244 92.732953) (xy 141.829721 92.815) (xy 142.250279 92.815) (xy 142.662756 92.732953) + (xy 143.051302 92.572012) (xy 143.215 92.462633) + ) + ) + (filled_polygon + (pts + (xy 168.601413 98.367719) (xy 168.510033 98.504479) (xy 168.447089 98.65644) (xy 168.415 98.81776) (xy 168.415 98.98224) + (xy 168.447089 99.14356) (xy 168.459533 99.173602) (xy 168.420506 99.194463) (xy 168.323815 99.273815) (xy 168.244463 99.370506) + (xy 168.185498 99.48082) (xy 168.149188 99.600518) (xy 168.136928 99.725) (xy 168.136928 101.025) (xy 168.149188 101.149482) + (xy 168.185498 101.26918) (xy 168.244463 101.379494) (xy 168.323815 101.476185) (xy 168.420506 101.555537) (xy 168.53082 101.614502) + (xy 168.650518 101.650812) (xy 168.775 101.663072) (xy 169.725 101.663072) (xy 169.849482 101.650812) (xy 169.96918 101.614502) + (xy 170.079494 101.555537) (xy 170.176185 101.476185) (xy 170.255537 101.379494) (xy 170.314502 101.26918) (xy 170.350812 101.149482) + (xy 170.363072 101.025) (xy 170.363072 99.725) (xy 170.350812 99.600518) (xy 170.314502 99.48082) (xy 170.255537 99.370506) + (xy 170.176185 99.273815) (xy 170.079494 99.194463) (xy 170.040467 99.173602) (xy 170.052911 99.14356) (xy 170.085 98.98224) + (xy 170.085 98.81776) (xy 170.052911 98.65644) (xy 169.989967 98.504479) (xy 169.898587 98.367719) (xy 169.840858 98.30999) + (xy 170.970412 98.30999) (xy 171.965 99.304578) (xy 171.965 99.706521) (xy 171.960718 99.749999) (xy 171.977804 99.923489) + (xy 172.028411 100.090312) (xy 172.110589 100.244058) (xy 172.193467 100.345045) (xy 172.19347 100.345048) (xy 172.221183 100.378816) + (xy 172.242266 100.396118) (xy 170.498385 102.14) (xy 168.60232 102.14) (xy 168.564997 102.136324) (xy 168.527674 102.14) + (xy 168.527665 102.14) (xy 168.416012 102.150997) (xy 168.272751 102.194454) (xy 168.140722 102.265026) (xy 168.14072 102.265027) + (xy 168.140721 102.265027) (xy 168.053994 102.336201) (xy 168.05399 102.336205) (xy 168.024997 102.359999) (xy 168.001203 102.388992) + (xy 167.30999 103.080206) (xy 167.30999 98.30999) (xy 168.659142 98.30999) + ) + ) + (filled_polygon + (pts + (xy 153.121183 96.918817) (xy 153.255941 97.02941) (xy 153.409687 97.111588) (xy 153.57651 97.162195) (xy 153.75 97.179281) + (xy 153.92349 97.162195) (xy 154.090313 97.111588) (xy 154.123162 97.09403) (xy 154.217719 97.188587) (xy 154.354479 97.279967) + (xy 154.458077 97.322879) (xy 154.761928 97.62673) (xy 154.761928 98.065) (xy 154.774188 98.189482) (xy 154.810498 98.30918) + (xy 154.869463 98.419494) (xy 154.948815 98.516185) (xy 155.045506 98.595537) (xy 155.15582 98.654502) (xy 155.275518 98.690812) + (xy 155.4 98.703072) (xy 156.14 98.703072) (xy 156.14 98.895923) (xy 156.136565 98.9308) (xy 156.150273 99.069984) + (xy 156.190872 99.20382) (xy 156.2568 99.327163) (xy 156.345525 99.435275) (xy 156.44263 99.514967) (xy 156.453637 99.524) + (xy 156.57698 99.589928) (xy 156.710816 99.630527) (xy 156.85 99.644235) (xy 156.884877 99.6408) (xy 157.738069 99.6408) + (xy 157.328175 99.810583) (xy 156.888412 100.104424) (xy 156.514424 100.478412) (xy 156.220583 100.918175) (xy 156.018183 101.406814) + (xy 155.915 101.925551) (xy 155.915 102.454449) (xy 156.018183 102.973186) (xy 156.023749 102.986623) (xy 155.801302 102.837989) + (xy 155.492012 102.709877) (xy 155.527932 102.623158) (xy 155.585 102.33626) (xy 155.585 102.04374) (xy 155.527932 101.756842) + (xy 155.41599 101.486589) (xy 155.253475 101.243368) (xy 155.046632 101.036525) (xy 154.803411 100.87401) (xy 154.533158 100.762068) + (xy 154.24626 100.705) (xy 154.076697 100.705) (xy 153.982327 100.665911) (xy 153.676109 100.605) (xy 153.363891 100.605) + (xy 153.057673 100.665911) (xy 152.769221 100.785391) (xy 152.509621 100.95885) (xy 152.28885 101.179621) (xy 152.140881 101.401072) + (xy 152.140001 101.399999) (xy 152.111003 101.376201) (xy 151.113072 100.378271) (xy 151.113072 99.69) (xy 151.100812 99.565518) + (xy 151.064502 99.44582) (xy 151.005537 99.335506) (xy 150.926185 99.238815) (xy 150.829494 99.159463) (xy 150.766603 99.125846) + (xy 150.792002 99.105002) (xy 150.815805 99.075998) (xy 153.054383 96.837421) + ) + ) + (filled_polygon + (pts + (xy 149.149188 60.064482) (xy 149.185498 60.18418) (xy 149.244463 60.294494) (xy 149.323815 60.391185) (xy 149.420506 60.470537) + (xy 149.53082 60.529502) (xy 149.650518 60.565812) (xy 149.775 60.578072) (xy 150.725 60.578072) (xy 150.849482 60.565812) + (xy 150.96918 60.529502) (xy 151.079494 60.470537) (xy 151.176185 60.391185) (xy 151.226112 60.330349) (xy 151.25644 60.342911) + (xy 151.41776 60.375) (xy 151.490001 60.375) (xy 151.490001 62.725198) (xy 151.458078 62.757121) (xy 151.363072 62.796474) + (xy 151.363072 62.19) (xy 151.350812 62.065518) (xy 151.314502 61.94582) (xy 151.255537 61.835506) (xy 151.176185 61.738815) + (xy 151.079494 61.659463) (xy 151.077778 61.658546) (xy 151.085 61.62224) (xy 151.085 61.45776) (xy 151.052911 61.29644) + (xy 150.989967 61.144479) (xy 150.898587 61.007719) (xy 150.782281 60.891413) (xy 150.645521 60.800033) (xy 150.49356 60.737089) + (xy 150.33224 60.705) (xy 150.16776 60.705) (xy 150.00644 60.737089) (xy 149.854479 60.800033) (xy 149.717719 60.891413) + (xy 149.601413 61.007719) (xy 149.510033 61.144479) (xy 149.447089 61.29644) (xy 149.415 61.45776) (xy 149.415 61.62224) + (xy 149.422222 61.658546) (xy 149.420506 61.659463) (xy 149.323815 61.738815) (xy 149.244463 61.835506) (xy 149.185498 61.94582) + (xy 149.149188 62.065518) (xy 149.136928 62.19) (xy 149.136928 63.49) (xy 149.149188 63.614482) (xy 149.185498 63.73418) + (xy 149.244463 63.844494) (xy 149.323815 63.941185) (xy 149.420506 64.020537) (xy 149.49 64.057683) (xy 149.49 64.502677) + (xy 149.486324 64.54) (xy 149.49 64.577322) (xy 149.49 64.577332) (xy 149.500997 64.688985) (xy 149.542559 64.825998) + (xy 149.544454 64.832246) (xy 149.615026 64.964276) (xy 149.648896 65.005546) (xy 149.709999 65.080001) (xy 149.739003 65.103804) + (xy 149.933545 65.298347) (xy 149.919463 65.315506) (xy 149.860498 65.42582) (xy 149.824188 65.545518) (xy 149.811928 65.67) + (xy 149.811928 67.67) (xy 149.824188 67.794482) (xy 149.860498 67.91418) (xy 149.919463 68.024494) (xy 149.998815 68.121185) + (xy 150.095506 68.200537) (xy 150.0962 68.200908) (xy 150.065 68.35776) (xy 150.065 68.52224) (xy 150.097089 68.68356) + (xy 150.160033 68.835521) (xy 150.251413 68.972281) (xy 150.367719 69.088587) (xy 150.504479 69.179967) (xy 150.65644 69.242911) + (xy 150.81776 69.275) (xy 150.98224 69.275) (xy 151.14356 69.242911) (xy 151.295521 69.179967) (xy 151.432281 69.088587) + (xy 151.548587 68.972281) (xy 151.639967 68.835521) (xy 151.702911 68.68356) (xy 151.735 68.52224) (xy 151.735 68.35776) + (xy 151.725116 68.308072) (xy 152.75 68.308072) (xy 152.874482 68.295812) (xy 152.99418 68.259502) (xy 153.104494 68.200537) + (xy 153.201185 68.121185) (xy 153.228525 68.087872) (xy 153.429017 68.288364) (xy 153.778698 68.522013) (xy 153.994302 68.611319) + (xy 153.925 68.959721) (xy 153.925 69.380279) (xy 154.007047 69.792756) (xy 154.167988 70.181302) (xy 154.401637 70.530983) + (xy 154.699017 70.828363) (xy 155.048698 71.062012) (xy 155.437244 71.222953) (xy 155.849721 71.305) (xy 156.270279 71.305) + (xy 156.682756 71.222953) (xy 157.071302 71.062012) (xy 157.420983 70.828363) (xy 157.718363 70.530983) (xy 157.952012 70.181302) + (xy 158.112953 69.792756) (xy 158.195 69.380279) (xy 158.195 68.959721) (xy 158.112953 68.547244) (xy 157.952012 68.158698) + (xy 157.718363 67.809017) (xy 157.420983 67.511637) (xy 157.071302 67.277988) (xy 156.855698 67.188682) (xy 156.925 66.84028) + (xy 156.925 66.419722) (xy 156.873463 66.160627) (xy 156.888412 66.175576) (xy 157.328175 66.469417) (xy 157.816814 66.671817) + (xy 158.335551 66.775) (xy 158.581471 66.775) (xy 158.565996 66.826016) (xy 158.554999 66.937669) (xy 158.554999 66.937679) + (xy 158.551323 66.975001) (xy 158.554999 67.012324) (xy 158.555 71.26851) (xy 153.089003 76.734508) (xy 153.059999 76.758311) + (xy 153.009653 76.819658) (xy 152.965026 76.874036) (xy 152.896223 77.002756) (xy 152.894454 77.006066) (xy 152.850997 77.149327) + (xy 152.84 77.26098) (xy 152.84 77.26099) (xy 152.836324 77.298312) (xy 152.84 77.335634) (xy 152.84 77.692843) + (xy 152.797089 77.79644) (xy 152.765 77.95776) (xy 152.765 78.12224) (xy 152.797089 78.28356) (xy 152.860033 78.435521) + (xy 152.951413 78.572281) (xy 153.067719 78.688587) (xy 153.204479 78.779967) (xy 153.308077 78.822878) (xy 153.5612 79.076002) + (xy 153.584999 79.105001) (xy 153.613997 79.128799) (xy 153.700723 79.199974) (xy 153.813021 79.259999) (xy 153.832753 79.270546) + (xy 153.976014 79.314003) (xy 154.087667 79.325) (xy 154.087676 79.325) (xy 154.124999 79.328676) (xy 154.162322 79.325) + (xy 154.818954 79.325) (xy 154.869463 79.419494) (xy 154.948815 79.516185) (xy 154.995868 79.5548) (xy 150.863072 79.5548) + (xy 150.863072 79.14) (xy 150.850812 79.015518) (xy 150.814502 78.89582) (xy 150.755537 78.785506) (xy 150.676185 78.688815) + (xy 150.579494 78.609463) (xy 150.46918 78.550498) (xy 150.349482 78.514188) (xy 150.225 78.501928) (xy 149.275 78.501928) + (xy 149.150518 78.514188) (xy 149.03082 78.550498) (xy 148.920506 78.609463) (xy 148.823815 78.688815) (xy 148.744463 78.785506) + (xy 148.685498 78.89582) (xy 148.649188 79.015518) (xy 148.636928 79.14) (xy 148.636928 80.178975) (xy 148.610011 80.176324) + (xy 148.572688 80.18) (xy 148.572679 80.18) (xy 148.461026 80.190997) (xy 148.333259 80.229754) (xy 148.317765 80.234454) + (xy 148.185735 80.305026) (xy 148.109933 80.367236) (xy 148.070011 80.399999) (xy 148.046213 80.428997) (xy 147.208089 81.267121) + (xy 147.104491 81.310033) (xy 146.967731 81.401413) (xy 146.851425 81.517719) (xy 146.760045 81.654479) (xy 146.697101 81.80644) + (xy 146.665012 81.96776) (xy 146.665012 82.13224) (xy 146.697101 82.29356) (xy 146.760045 82.445521) (xy 146.851425 82.582281) + (xy 146.967731 82.698587) (xy 147.104491 82.789967) (xy 147.256452 82.852911) (xy 147.417772 82.885) (xy 147.582252 82.885) + (xy 147.743572 82.852911) (xy 147.895533 82.789967) (xy 148.032293 82.698587) (xy 148.148599 82.582281) (xy 148.239979 82.445521) + (xy 148.282891 82.341923) (xy 148.924814 81.7) (xy 149.402843 81.7) (xy 149.50644 81.742911) (xy 149.66776 81.775) + (xy 149.83224 81.775) (xy 149.99356 81.742911) (xy 150.145521 81.679967) (xy 150.282281 81.588587) (xy 150.398587 81.472281) + (xy 150.489967 81.335521) (xy 150.552911 81.18356) (xy 150.574545 81.0748) (xy 156.435065 81.0748) (xy 156.535325 81.105213) + (xy 156.646978 81.11621) (xy 156.684311 81.119887) (xy 156.721644 81.11621) (xy 156.876626 81.11621) (xy 156.514424 81.478412) + (xy 156.220583 81.918175) (xy 156.018183 82.406814) (xy 155.915 82.925551) (xy 155.915 83.454449) (xy 156.018183 83.973186) + (xy 156.023749 83.986623) (xy 155.801302 83.837989) (xy 155.492012 83.709877) (xy 155.527932 83.623158) (xy 155.585 83.33626) + (xy 155.585 83.04374) (xy 155.527932 82.756842) (xy 155.41599 82.486589) (xy 155.253475 82.243368) (xy 155.046632 82.036525) + (xy 154.803411 81.87401) (xy 154.533158 81.762068) (xy 154.24626 81.705) (xy 154.076697 81.705) (xy 153.982327 81.665911) + (xy 153.676109 81.605) (xy 153.363891 81.605) (xy 153.057673 81.665911) (xy 152.769221 81.785391) (xy 152.509621 81.95885) + (xy 152.28885 82.179621) (xy 152.115391 82.439221) (xy 151.995911 82.727673) (xy 151.935 83.033891) (xy 151.935 83.346109) + (xy 151.995911 83.652327) (xy 152.115391 83.940779) (xy 152.243113 84.131928) (xy 151.036729 84.131928) (xy 150.863072 83.958271) + (xy 150.863072 82.69) (xy 150.850812 82.565518) (xy 150.814502 82.44582) (xy 150.755537 82.335506) (xy 150.676185 82.238815) + (xy 150.579494 82.159463) (xy 150.46918 82.100498) (xy 150.349482 82.064188) (xy 150.225 82.051928) (xy 149.275 82.051928) + (xy 149.150518 82.064188) (xy 149.03082 82.100498) (xy 148.920506 82.159463) (xy 148.823815 82.238815) (xy 148.744463 82.335506) + (xy 148.685498 82.44582) (xy 148.649188 82.565518) (xy 148.636928 82.69) (xy 148.636928 83.99) (xy 148.649188 84.114482) + (xy 148.685498 84.23418) (xy 148.744463 84.344494) (xy 148.823815 84.441185) (xy 148.920506 84.520537) (xy 149.03082 84.579502) + (xy 149.150518 84.615812) (xy 149.275 84.628072) (xy 149.383271 84.628072) (xy 149.811928 85.056729) (xy 149.811928 86.77) + (xy 149.824188 86.894482) (xy 149.860498 87.01418) (xy 149.919463 87.124494) (xy 149.998815 87.221185) (xy 150.04 87.254985) + (xy 150.04 87.292842) (xy 149.997089 87.39644) (xy 149.965 87.55776) (xy 149.965 87.72224) (xy 149.997089 87.88356) + (xy 150.060033 88.035521) (xy 150.151413 88.172281) (xy 150.267719 88.288587) (xy 150.404479 88.379967) (xy 150.55644 88.442911) + (xy 150.71776 88.475) (xy 150.88224 88.475) (xy 151.04356 88.442911) (xy 151.195521 88.379967) (xy 151.332281 88.288587) + (xy 151.448587 88.172281) (xy 151.539967 88.035521) (xy 151.602911 87.88356) (xy 151.635 87.72224) (xy 151.635 87.55776) + (xy 151.605225 87.408072) (xy 152.75 87.408072) (xy 152.874482 87.395812) (xy 152.99418 87.359502) (xy 153.104494 87.300537) + (xy 153.201185 87.221185) (xy 153.228525 87.187872) (xy 153.429017 87.388364) (xy 153.778698 87.622013) (xy 153.994302 87.711319) + (xy 153.925 88.059721) (xy 153.925 88.480279) (xy 154.007047 88.892756) (xy 154.167988 89.281302) (xy 154.401637 89.630983) + (xy 154.699017 89.928363) (xy 155.048698 90.162012) (xy 155.437244 90.322953) (xy 155.849721 90.405) (xy 156.270279 90.405) + (xy 156.682756 90.322953) (xy 157.071302 90.162012) (xy 157.420983 89.928363) (xy 157.718363 89.630983) (xy 157.952012 89.281302) + (xy 158.112953 88.892756) (xy 158.195 88.480279) (xy 158.195 88.059721) (xy 158.112953 87.647244) (xy 157.952012 87.258698) + (xy 157.718363 86.909017) (xy 157.420983 86.611637) (xy 157.071302 86.377988) (xy 156.855698 86.288682) (xy 156.925 85.94028) + (xy 156.925 85.519722) (xy 156.873463 85.260627) (xy 156.888412 85.275576) (xy 157.328175 85.569417) (xy 157.816814 85.771817) + (xy 158.335551 85.875) (xy 158.864449 85.875) (xy 159.383186 85.771817) (xy 159.871825 85.569417) (xy 160.311588 85.275576) + (xy 160.326537 85.260627) (xy 160.275 85.519721) (xy 160.275 85.940279) (xy 160.344302 86.288682) (xy 160.128698 86.377988) + (xy 159.779017 86.611637) (xy 159.481637 86.909017) (xy 159.247988 87.258698) (xy 159.087047 87.647244) (xy 159.005 88.059721) + (xy 159.005 88.480279) (xy 159.087047 88.892756) (xy 159.247988 89.281302) (xy 159.481637 89.630983) (xy 159.779017 89.928363) + (xy 160.128698 90.162012) (xy 160.517244 90.322953) (xy 160.929721 90.405) (xy 161.350279 90.405) (xy 161.762756 90.322953) + (xy 162.151302 90.162012) (xy 162.500983 89.928363) (xy 162.540001 89.889345) (xy 162.54 90.292843) (xy 162.497089 90.39644) + (xy 162.465 90.55776) (xy 162.465 90.72224) (xy 162.497089 90.88356) (xy 162.560033 91.035521) (xy 162.651413 91.172281) + (xy 162.767719 91.288587) (xy 162.904479 91.379967) (xy 163.008078 91.422879) (xy 164.195001 92.609803) (xy 164.195002 100.687729) + (xy 164.142327 100.665911) (xy 163.836109 100.605) (xy 163.523891 100.605) (xy 163.217673 100.665911) (xy 163.123303 100.705) + (xy 162.95374 100.705) (xy 162.666842 100.762068) (xy 162.396589 100.87401) (xy 162.153368 101.036525) (xy 161.946525 101.243368) + (xy 161.78401 101.486589) (xy 161.672068 101.756842) (xy 161.615 102.04374) (xy 161.615 102.33626) (xy 161.672068 102.623158) + (xy 161.707988 102.709876) (xy 161.398698 102.837988) (xy 161.176252 102.986622) (xy 161.181817 102.973186) (xy 161.285 102.454449) + (xy 161.285 101.925551) (xy 161.181817 101.406814) (xy 160.979417 100.918175) (xy 160.685576 100.478412) (xy 160.311588 100.104424) + (xy 159.871825 99.810583) (xy 159.461931 99.6408) (xy 160.315123 99.6408) (xy 160.35 99.644235) (xy 160.384877 99.6408) + (xy 160.489184 99.630527) (xy 160.62302 99.589928) (xy 160.746363 99.524) (xy 160.854475 99.435275) (xy 160.9432 99.327163) + (xy 161.009128 99.20382) (xy 161.049727 99.069984) (xy 161.063435 98.9308) (xy 161.06 98.895923) (xy 161.06 98.7) + (xy 161.127002 98.7) (xy 161.127002 98.541252) (xy 161.28575 98.7) (xy 161.8 98.703072) (xy 161.924482 98.690812) + (xy 162.04418 98.654502) (xy 162.154494 98.595537) (xy 162.251185 98.516185) (xy 162.330537 98.419494) (xy 162.389502 98.30918) + (xy 162.425812 98.189482) (xy 162.438072 98.065) (xy 162.435 97.85075) (xy 162.27625 97.692) (xy 161.127 97.692) + (xy 161.127 97.712) (xy 161.06 97.712) (xy 161.06 97.418) (xy 161.127 97.418) (xy 161.127 97.438) + (xy 162.27625 97.438) (xy 162.435 97.27925) (xy 162.438072 97.065) (xy 162.425812 96.940518) (xy 162.389502 96.82082) + (xy 162.330537 96.710506) (xy 162.313708 96.69) (xy 162.330537 96.669494) (xy 162.389502 96.55918) (xy 162.425812 96.439482) + (xy 162.438072 96.315) (xy 162.438072 95.315) (xy 162.425812 95.190518) (xy 162.389502 95.07082) (xy 162.330537 94.960506) + (xy 162.263741 94.879115) (xy 162.285 94.77224) (xy 162.285 94.60776) (xy 162.252911 94.44644) (xy 162.189967 94.294479) + (xy 162.098587 94.157719) (xy 161.982281 94.041413) (xy 161.845521 93.950033) (xy 161.741923 93.907122) (xy 161.363803 93.529002) + (xy 161.340001 93.499999) (xy 161.224276 93.405026) (xy 161.092247 93.334454) (xy 160.948986 93.290997) (xy 160.837333 93.28) + (xy 160.837322 93.28) (xy 160.8 93.276324) (xy 160.762678 93.28) (xy 156.584801 93.28) (xy 159.041924 90.822878) + (xy 159.145521 90.779967) (xy 159.282281 90.688587) (xy 159.398587 90.572281) (xy 159.489967 90.435521) (xy 159.552911 90.28356) + (xy 159.585 90.12224) (xy 159.585 89.95776) (xy 159.552911 89.79644) (xy 159.489967 89.644479) (xy 159.398587 89.507719) + (xy 159.282281 89.391413) (xy 159.145521 89.300033) (xy 158.99356 89.237089) (xy 158.83224 89.205) (xy 158.66776 89.205) + (xy 158.50644 89.237089) (xy 158.354479 89.300033) (xy 158.217719 89.391413) (xy 158.101413 89.507719) (xy 158.010033 89.644479) + (xy 157.967122 89.748076) (xy 155.685683 92.029516) (xy 155.64356 92.012068) (xy 155.48224 91.979979) (xy 155.31776 91.979979) + (xy 155.15644 92.012068) (xy 155.004479 92.075012) (xy 154.867719 92.166392) (xy 154.751413 92.282698) (xy 154.660033 92.419458) + (xy 154.597089 92.571419) (xy 154.565 92.732739) (xy 154.565 92.897219) (xy 154.597089 93.058539) (xy 154.660033 93.2105) + (xy 154.708521 93.283068) (xy 154.628016 93.290997) (xy 154.484755 93.334454) (xy 154.352726 93.405026) (xy 154.237001 93.499999) + (xy 154.213203 93.528997) (xy 151.113072 96.629129) (xy 151.113072 96.14) (xy 151.100812 96.015518) (xy 151.064502 95.89582) + (xy 151.005537 95.785506) (xy 150.926185 95.688815) (xy 150.829494 95.609463) (xy 150.71918 95.550498) (xy 150.599482 95.514188) + (xy 150.475 95.501928) (xy 149.525 95.501928) (xy 149.400518 95.514188) (xy 149.28082 95.550498) (xy 149.170506 95.609463) + (xy 149.073815 95.688815) (xy 148.994463 95.785506) (xy 148.935498 95.89582) (xy 148.899188 96.015518) (xy 148.886928 96.14) + (xy 148.886928 97.44) (xy 148.899188 97.564482) (xy 148.935498 97.68418) (xy 148.994463 97.794494) (xy 149.073815 97.891185) + (xy 149.165 97.966018) (xy 149.165 98.02224) (xy 149.197089 98.18356) (xy 149.221853 98.243345) (xy 147.616382 99.848817) + (xy 147.511223 99.905026) (xy 147.438647 99.964588) (xy 147.395499 99.999999) (xy 147.371701 100.028997) (xy 146.615001 100.785698) + (xy 146.615001 94.367314) (xy 146.618677 94.329991) (xy 146.615001 94.292668) (xy 146.615001 94.292658) (xy 146.604004 94.181005) + (xy 146.560547 94.037744) (xy 146.537312 93.994275) (xy 146.489975 93.905714) (xy 146.4188 93.818988) (xy 146.395002 93.78999) + (xy 146.366004 93.766192) (xy 144.957883 92.358072) (xy 146.35 92.358072) (xy 146.474482 92.345812) (xy 146.59418 92.309502) + (xy 146.704494 92.250537) (xy 146.801185 92.171185) (xy 146.880537 92.074494) (xy 146.939502 91.96418) (xy 146.975812 91.844482) + (xy 146.988072 91.72) (xy 146.988072 89.72) (xy 146.975812 89.595518) (xy 146.939502 89.47582) (xy 146.880537 89.365506) + (xy 146.801185 89.268815) (xy 146.704494 89.189463) (xy 146.615001 89.141627) (xy 146.615001 75.492334) (xy 146.618678 75.455001) + (xy 146.604004 75.306015) (xy 146.560547 75.162754) (xy 146.489975 75.030725) (xy 146.4188 74.943998) (xy 146.395002 74.915) + (xy 146.366005 74.891203) (xy 145.082879 73.608078) (xy 145.06 73.552843) (xy 145.06 73.358072) (xy 146.35 73.358072) + (xy 146.474482 73.345812) (xy 146.59418 73.309502) (xy 146.704494 73.250537) (xy 146.801185 73.171185) (xy 146.880537 73.074494) + (xy 146.939502 72.96418) (xy 146.975812 72.844482) (xy 146.988072 72.72) (xy 146.988072 70.72) (xy 146.975812 70.595518) + (xy 146.939502 70.47582) (xy 146.880537 70.365506) (xy 146.801185 70.268815) (xy 146.704494 70.189463) (xy 146.615001 70.141627) + (xy 146.615001 61.896568) (xy 146.77616 61.864511) (xy 146.928121 61.801567) (xy 147.064881 61.710187) (xy 147.181187 61.593881) + (xy 147.272567 61.457121) (xy 147.315478 61.353523) (xy 147.511002 61.158) (xy 147.540001 61.134201) (xy 147.634974 61.018476) + (xy 147.705546 60.886447) (xy 147.749003 60.743185) (xy 147.76 60.631532) (xy 147.76 60.631524) (xy 147.762985 60.601216) + (xy 148.314202 60.05) (xy 149.147762 60.05) + ) + ) + (filled_polygon + (pts + (xy 130 94.49728) (xy 130.043477 94.492998) (xy 131.24142 94.492998) (xy 134.115 97.366579) (xy 134.115001 98.373674) + (xy 134.115 98.373682) (xy 134.115 98.373689) (xy 134.110719 98.417158) (xy 134.115 98.460627) (xy 134.115 99.243481) + (xy 134.127805 99.373494) (xy 134.169523 99.511014) (xy 134.178412 99.540317) (xy 134.26059 99.694063) (xy 134.371184 99.828821) + (xy 134.505942 99.939415) (xy 134.659688 100.021593) (xy 134.826511 100.072199) (xy 135 100.089286) (xy 135.08523 100.080892) + (xy 135.12373 100.127804) (xy 135.16001 100.172011) (xy 135.189008 100.195809) (xy 135.479196 100.485997) (xy 135.502999 100.515001) + (xy 135.618724 100.609974) (xy 135.667965 100.636294) (xy 135.674188 100.699482) (xy 135.710498 100.81918) (xy 135.769463 100.929494) + (xy 135.848815 101.026185) (xy 135.910165 101.076533) (xy 134.378292 102.608407) (xy 131.777354 102.608407) (xy 131.829494 102.580537) + (xy 131.926185 102.501185) (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) + (xy 132.113072 100.75) (xy 132.100812 100.625518) (xy 132.064502 100.50582) (xy 132.005537 100.395506) (xy 131.926185 100.298815) + (xy 131.829494 100.219463) (xy 131.71918 100.160498) (xy 131.599482 100.124188) (xy 131.475 100.111928) (xy 131.463832 100.111928) + (xy 131.902826 99.818601) (xy 132.318601 99.402826) (xy 132.645273 98.913928) (xy 132.870288 98.370692) (xy 132.985 97.793997) + (xy 132.985 97.206003) (xy 132.870288 96.629308) (xy 132.645273 96.086072) (xy 132.318601 95.597174) (xy 131.902826 95.181399) + (xy 131.413928 94.854727) (xy 130.870692 94.629712) (xy 130.293997 94.515) (xy 129.706003 94.515) (xy 129.629325 94.530252) + (xy 129.666579 94.492998) (xy 129.956524 94.492998) + ) + ) + (filled_polygon + (pts + (xy 171.59 79.691579) (xy 171.590001 80.581521) (xy 171.585719 80.625) (xy 171.602805 80.79849) (xy 171.653412 80.965313) + (xy 171.73559 81.119059) (xy 171.818468 81.220046) (xy 171.818471 81.220049) (xy 171.846184 81.253817) (xy 171.879951 81.281529) + (xy 172.504953 81.906532) (xy 172.60594 81.98941) (xy 172.759686 82.071588) (xy 172.926509 82.122194) (xy 173.099999 82.139281) + (xy 173.273489 82.122194) (xy 173.440313 82.071588) (xy 173.594058 81.98941) (xy 173.728816 81.878816) (xy 173.829954 81.75558) + (xy 173.869463 81.829494) (xy 173.948815 81.926185) (xy 174.045506 82.005537) (xy 174.15582 82.064502) (xy 174.275518 82.100812) + (xy 174.4 82.113072) (xy 174.490001 82.113072) (xy 174.49 83.077843) (xy 174.447089 83.18144) (xy 174.415 83.34276) + (xy 174.415 83.50724) (xy 174.447089 83.66856) (xy 174.465 83.711801) (xy 174.465 85.014909) (xy 174.41599 84.896589) + (xy 174.253475 84.653368) (xy 174.046632 84.446525) (xy 173.803411 84.28401) (xy 173.533158 84.172068) (xy 173.24626 84.115) + (xy 173.076697 84.115) (xy 172.982327 84.075911) (xy 172.676109 84.015) (xy 172.363891 84.015) (xy 172.057673 84.075911) + (xy 171.769221 84.195391) (xy 171.509621 84.36885) (xy 171.28885 84.589621) (xy 171.115391 84.849221) (xy 170.995911 85.137673) + (xy 170.935 85.443891) (xy 170.935 85.756109) (xy 170.995911 86.062327) (xy 171.115391 86.350779) (xy 171.243113 86.541928) + (xy 170.579862 86.541928) (xy 170.552911 86.40644) (xy 170.544414 86.385925) (xy 170.554494 86.380537) (xy 170.651185 86.301185) + (xy 170.730537 86.204494) (xy 170.789502 86.09418) (xy 170.825812 85.974482) (xy 170.838072 85.85) (xy 170.838072 84.55) + (xy 170.825812 84.425518) (xy 170.789502 84.30582) (xy 170.730537 84.195506) (xy 170.651185 84.098815) (xy 170.554494 84.019463) + (xy 170.44418 83.960498) (xy 170.324482 83.924188) (xy 170.2 83.911928) (xy 169.25 83.911928) (xy 169.125518 83.924188) + (xy 169.00582 83.960498) (xy 168.895506 84.019463) (xy 168.798815 84.098815) (xy 168.719463 84.195506) (xy 168.660498 84.30582) + (xy 168.624188 84.425518) (xy 168.611928 84.55) (xy 168.611928 85.85) (xy 168.624188 85.974482) (xy 168.660498 86.09418) + (xy 168.719463 86.204494) (xy 168.798815 86.301185) (xy 168.895506 86.380537) (xy 168.946789 86.407949) (xy 168.915 86.56776) + (xy 168.915 86.73224) (xy 168.930803 86.811688) (xy 168.919463 86.825506) (xy 168.860498 86.93582) (xy 168.824188 87.055518) + (xy 168.811928 87.18) (xy 168.811928 89.18) (xy 168.824188 89.304482) (xy 168.860498 89.42418) (xy 168.919463 89.534494) + (xy 168.998815 89.631185) (xy 169.095506 89.710537) (xy 169.0962 89.710908) (xy 169.065 89.86776) (xy 169.065 90.03224) + (xy 169.097089 90.19356) (xy 169.160033 90.345521) (xy 169.251413 90.482281) (xy 169.367719 90.598587) (xy 169.504479 90.689967) + (xy 169.65644 90.752911) (xy 169.81776 90.785) (xy 169.98224 90.785) (xy 170.14356 90.752911) (xy 170.295521 90.689967) + (xy 170.432281 90.598587) (xy 170.548587 90.482281) (xy 170.639967 90.345521) (xy 170.702911 90.19356) (xy 170.735 90.03224) + (xy 170.735 89.86776) (xy 170.725116 89.818072) (xy 171.75 89.818072) (xy 171.874482 89.805812) (xy 171.99418 89.769502) + (xy 172.104494 89.710537) (xy 172.201185 89.631185) (xy 172.228525 89.597872) (xy 172.429017 89.798364) (xy 172.778698 90.032013) + (xy 172.994302 90.121319) (xy 172.925 90.469721) (xy 172.925 90.890279) (xy 173.007047 91.302756) (xy 173.167988 91.691302) + (xy 173.401637 92.040983) (xy 173.699017 92.338363) (xy 174.048698 92.572012) (xy 174.437244 92.732953) (xy 174.849721 92.815) + (xy 175.270279 92.815) (xy 175.682756 92.732953) (xy 176.071302 92.572012) (xy 176.420983 92.338363) (xy 176.718363 92.040983) + (xy 176.952012 91.691302) (xy 177.112953 91.302756) (xy 177.195 90.890279) (xy 177.195 90.469721) (xy 177.112953 90.057244) + (xy 176.957751 89.682552) (xy 177.555 90.279802) (xy 177.554999 94.777676) (xy 177.551323 94.814999) (xy 177.554999 94.852321) + (xy 177.554999 94.852331) (xy 177.565996 94.963984) (xy 177.602854 95.08549) (xy 177.609453 95.107245) (xy 177.680025 95.239275) + (xy 177.711131 95.277177) (xy 177.774998 95.355) (xy 177.804002 95.378803) (xy 178.765198 96.34) (xy 175.884877 96.34) + (xy 175.85 96.336565) (xy 175.815123 96.34) (xy 175.710816 96.350273) (xy 175.57698 96.390872) (xy 175.453637 96.4568) + (xy 175.345525 96.545525) (xy 175.2568 96.653637) (xy 175.190872 96.77698) (xy 175.150273 96.910816) (xy 175.136565 97.05) + (xy 175.140001 97.084887) (xy 175.140001 97.186928) (xy 174.4 97.186928) (xy 174.275518 97.199188) (xy 174.15582 97.235498) + (xy 174.045506 97.294463) (xy 173.948815 97.373815) (xy 173.894499 97.44) (xy 173.406463 97.44) (xy 173.362997 97.435719) + (xy 173.319531 97.44) (xy 173.319521 97.44) (xy 173.189508 97.452805) (xy 173.022685 97.503411) (xy 172.868939 97.585589) + (xy 172.803155 97.639577) (xy 171.993524 96.829946) (xy 171.965807 96.796173) (xy 171.831049 96.685579) (xy 171.677303 96.603401) + (xy 171.51048 96.552795) (xy 171.380467 96.53999) (xy 171.380459 96.53999) (xy 171.33699 96.535709) (xy 171.293521 96.53999) + (xy 167.30999 96.53999) (xy 167.30999 93.54276) (xy 167.915 93.54276) (xy 167.915 93.70724) (xy 167.947089 93.86856) + (xy 168.010033 94.020521) (xy 168.101413 94.157281) (xy 168.217719 94.273587) (xy 168.354479 94.364967) (xy 168.50644 94.427911) + (xy 168.66776 94.46) (xy 168.710199 94.46) (xy 169.217122 94.966923) (xy 169.260033 95.070521) (xy 169.351413 95.207281) + (xy 169.467719 95.323587) (xy 169.604479 95.414967) (xy 169.75644 95.477911) (xy 169.91776 95.51) (xy 170.08224 95.51) + (xy 170.24356 95.477911) (xy 170.395521 95.414967) (xy 170.532281 95.323587) (xy 170.648587 95.207281) (xy 170.739967 95.070521) + (xy 170.802911 94.91856) (xy 170.835 94.75724) (xy 170.835 94.59276) (xy 170.802911 94.43144) (xy 170.739967 94.279479) + (xy 170.648587 94.142719) (xy 170.532281 94.026413) (xy 170.395521 93.935033) (xy 170.291923 93.892122) (xy 169.538804 93.139002) + (xy 169.515001 93.109999) (xy 169.399276 93.015026) (xy 169.267247 92.944454) (xy 169.207183 92.926234) (xy 169.145521 92.885033) + (xy 168.99356 92.822089) (xy 168.83224 92.79) (xy 168.66776 92.79) (xy 168.50644 92.822089) (xy 168.354479 92.885033) + (xy 168.217719 92.976413) (xy 168.101413 93.092719) (xy 168.010033 93.229479) (xy 167.947089 93.38144) (xy 167.915 93.54276) + (xy 167.30999 93.54276) (xy 167.30999 92.981588) (xy 167.981532 92.310047) (xy 168.06441 92.20906) (xy 168.146588 92.055314) + (xy 168.197194 91.888491) (xy 168.214281 91.715001) (xy 168.197194 91.541511) (xy 168.146588 91.374687) (xy 168.06441 91.220942) + (xy 167.953817 91.086183) (xy 167.819058 90.97559) (xy 167.665313 90.893412) (xy 167.498489 90.842806) (xy 167.324999 90.825719) + (xy 167.151509 90.842806) (xy 166.984686 90.893412) (xy 166.83094 90.97559) (xy 166.729953 91.058468) (xy 165.829946 91.958476) + (xy 165.796173 91.986193) (xy 165.693481 92.111324) (xy 165.660547 92.002754) (xy 165.589975 91.870725) (xy 165.495002 91.755) + (xy 165.466005 91.731203) (xy 164.082879 90.348078) (xy 164.06 90.292843) (xy 164.06 89.948072) (xy 165.45 89.948072) + (xy 165.574482 89.935812) (xy 165.69418 89.899502) (xy 165.804494 89.840537) (xy 165.901185 89.761185) (xy 165.980537 89.664494) + (xy 166.039502 89.55418) (xy 166.075812 89.434482) (xy 166.088072 89.31) (xy 166.088072 87.31) (xy 166.075812 87.185518) + (xy 166.039502 87.06582) (xy 165.980537 86.955506) (xy 165.901185 86.858815) (xy 165.804494 86.779463) (xy 165.76 86.75568) + (xy 165.76 81.887178) (xy 165.802911 81.783581) (xy 165.804614 81.77502) (xy 165.866419 81.77502) (xy 166.2524 82.161002) + (xy 166.276199 82.190001) (xy 166.391924 82.284974) (xy 166.523953 82.355546) (xy 166.667214 82.399003) (xy 166.778867 82.41) + (xy 166.778876 82.41) (xy 166.816199 82.413676) (xy 166.853522 82.41) (xy 168.622762 82.41) (xy 168.624188 82.424482) + (xy 168.660498 82.54418) (xy 168.719463 82.654494) (xy 168.798815 82.751185) (xy 168.895506 82.830537) (xy 169.00582 82.889502) + (xy 169.125518 82.925812) (xy 169.25 82.938072) (xy 170.2 82.938072) (xy 170.324482 82.925812) (xy 170.44418 82.889502) + (xy 170.554494 82.830537) (xy 170.651185 82.751185) (xy 170.730537 82.654494) (xy 170.789502 82.54418) (xy 170.825812 82.424482) + (xy 170.827242 82.409965) (xy 170.875521 82.389967) (xy 171.012281 82.298587) (xy 171.128587 82.182281) (xy 171.219967 82.045521) + (xy 171.282911 81.89356) (xy 171.315 81.73224) (xy 171.315 81.56776) (xy 171.282911 81.40644) (xy 171.219967 81.254479) + (xy 171.128587 81.117719) (xy 171.012281 81.001413) (xy 170.875521 80.910033) (xy 170.827242 80.890035) (xy 170.825812 80.875518) + (xy 170.789502 80.75582) (xy 170.730537 80.645506) (xy 170.651185 80.548815) (xy 170.554494 80.469463) (xy 170.44418 80.410498) + (xy 170.324482 80.374188) (xy 170.2 80.361928) (xy 169.25 80.361928) (xy 169.125518 80.374188) (xy 169.00582 80.410498) + (xy 168.895506 80.469463) (xy 168.798815 80.548815) (xy 168.719463 80.645506) (xy 168.660498 80.75582) (xy 168.624188 80.875518) + (xy 168.622762 80.89) (xy 167.131002 80.89) (xy 166.745023 80.504022) (xy 166.721221 80.475019) (xy 166.605496 80.380046) + (xy 166.473467 80.309474) (xy 166.403368 80.28821) (xy 167.691579 79) (xy 170.898422 79) + ) + ) + (filled_polygon + (pts + (xy 124.598815 94.671185) (xy 124.695506 94.750537) (xy 124.790001 94.801046) (xy 124.79 95.252843) (xy 124.747089 95.35644) + (xy 124.715 95.51776) (xy 124.715 95.68224) (xy 124.747089 95.84356) (xy 124.810033 95.995521) (xy 124.901413 96.132281) + (xy 125.017719 96.248587) (xy 125.154479 96.339967) (xy 125.269012 96.387408) (xy 124.14142 97.515) (xy 119.096613 97.515) + (xy 121.726003 94.885611) (xy 121.736651 94.876873) (xy 122.028698 95.072012) (xy 122.417244 95.232953) (xy 122.829721 95.315) + (xy 123.250279 95.315) (xy 123.662756 95.232953) (xy 124.051302 95.072012) (xy 124.400983 94.838363) (xy 124.584998 94.654348) + ) + ) + (filled_polygon + (pts + (xy 139.454999 90.1788) (xy 139.455 94.777667) (xy 139.451323 94.814999) (xy 139.455 94.852331) (xy 139.455 94.852332) + (xy 139.465997 94.963985) (xy 139.477629 95.002331) (xy 139.509453 95.107245) (xy 139.580025 95.239275) (xy 139.647048 95.320942) + (xy 139.674999 95.355) (xy 139.703997 95.378798) (xy 140.665198 96.34) (xy 137.784877 96.34) (xy 137.75 96.336565) + (xy 137.715123 96.34) (xy 137.610816 96.350273) (xy 137.47698 96.390872) (xy 137.353637 96.4568) (xy 137.245525 96.545525) + (xy 137.1568 96.653637) (xy 137.090872 96.77698) (xy 137.050273 96.910816) (xy 137.036565 97.05) (xy 137.040001 97.084887) + (xy 137.040001 97.186928) (xy 136.3 97.186928) (xy 136.175518 97.199188) (xy 136.123396 97.214999) (xy 135.885 97.214999) + (xy 135.885 97.043465) (xy 135.889281 96.999999) (xy 135.885 96.956533) (xy 135.885 96.956523) (xy 135.872195 96.82651) + (xy 135.821589 96.659687) (xy 135.739411 96.505941) (xy 135.684628 96.439188) (xy 135.656532 96.404953) (xy 135.65653 96.404951) + (xy 135.628817 96.371183) (xy 135.59505 96.343471) (xy 132.264532 93.012954) (xy 132.236815 92.979181) (xy 132.102057 92.868587) + (xy 131.948311 92.786409) (xy 131.781488 92.735803) (xy 131.651475 92.722998) (xy 131.651467 92.722998) (xy 131.607998 92.718717) + (xy 131.564529 92.722998) (xy 130.885 92.722998) (xy 130.885 90.407717) (xy 130.901413 90.432281) (xy 131.017719 90.548587) + (xy 131.154479 90.639967) (xy 131.30644 90.702911) (xy 131.46776 90.735) (xy 131.63224 90.735) (xy 131.79356 90.702911) + (xy 131.945521 90.639967) (xy 132.082281 90.548587) (xy 132.198587 90.432281) (xy 132.289967 90.295521) (xy 132.352911 90.14356) + (xy 132.385 89.98224) (xy 132.385 89.818072) (xy 133.65 89.818072) (xy 133.774482 89.805812) (xy 133.89418 89.769502) + (xy 134.004494 89.710537) (xy 134.101185 89.631185) (xy 134.128525 89.597872) (xy 134.329017 89.798364) (xy 134.678698 90.032013) + (xy 134.894302 90.121319) (xy 134.825 90.469721) (xy 134.825 90.890279) (xy 134.907047 91.302756) (xy 135.067988 91.691302) + (xy 135.301637 92.040983) (xy 135.599017 92.338363) (xy 135.948698 92.572012) (xy 136.337244 92.732953) (xy 136.749721 92.815) + (xy 137.170279 92.815) (xy 137.582756 92.732953) (xy 137.971302 92.572012) (xy 138.320983 92.338363) (xy 138.618363 92.040983) + (xy 138.852012 91.691302) (xy 139.012953 91.302756) (xy 139.095 90.890279) (xy 139.095 90.469721) (xy 139.012953 90.057244) + (xy 138.852012 89.668698) (xy 138.664973 89.388773) + ) + ) + (filled_polygon + (pts + (xy 133.732003 57.233582) (xy 133.732002 60.081523) (xy 133.72772 60.125) (xy 133.732002 60.168477) (xy 133.732002 60.268476) + (xy 133.740784 60.357638) (xy 131.583422 62.515) (xy 130.913072 62.515) (xy 130.913072 61.375) (xy 130.900812 61.250518) + (xy 130.864502 61.13082) (xy 130.805537 61.020506) (xy 130.726185 60.923815) (xy 130.629494 60.844463) (xy 130.51918 60.785498) + (xy 130.399482 60.749188) (xy 130.275 60.736928) (xy 129.325 60.736928) (xy 129.200518 60.749188) (xy 129.08082 60.785498) + (xy 128.970506 60.844463) (xy 128.873815 60.923815) (xy 128.794463 61.020506) (xy 128.735498 61.13082) (xy 128.699188 61.250518) + (xy 128.686928 61.375) (xy 128.686928 61.64) (xy 128.587155 61.64) (xy 128.531921 61.617121) (xy 128.403801 61.489002) + (xy 128.379999 61.459999) (xy 128.264274 61.365026) (xy 128.132245 61.294454) (xy 127.988984 61.250997) (xy 127.902482 61.242477) + (xy 127.900812 61.225518) (xy 127.864502 61.10582) (xy 127.805537 60.995506) (xy 127.726185 60.898815) (xy 127.629494 60.819463) + (xy 127.51918 60.760498) (xy 127.399482 60.724188) (xy 127.275 60.711928) (xy 126.325 60.711928) (xy 126.200518 60.724188) + (xy 126.08082 60.760498) (xy 125.970506 60.819463) (xy 125.873815 60.898815) (xy 125.794463 60.995506) (xy 125.735498 61.10582) + (xy 125.699188 61.225518) (xy 125.686928 61.35) (xy 125.686928 62.65) (xy 125.699188 62.774482) (xy 125.735498 62.89418) + (xy 125.794463 63.004494) (xy 125.873815 63.101185) (xy 125.970506 63.180537) (xy 126.08082 63.239502) (xy 126.200518 63.275812) + (xy 126.325 63.288072) (xy 127.275 63.288072) (xy 127.399482 63.275812) (xy 127.51918 63.239502) (xy 127.629494 63.180537) + (xy 127.726185 63.101185) (xy 127.747523 63.075184) (xy 127.844477 63.139967) (xy 127.996438 63.202911) (xy 128.157758 63.235) + (xy 128.322238 63.235) (xy 128.483558 63.202911) (xy 128.538101 63.180319) (xy 128.25495 63.46347) (xy 128.221183 63.491182) + (xy 128.19347 63.52495) (xy 128.193467 63.524953) (xy 128.110589 63.62594) (xy 128.028411 63.779686) (xy 127.977804 63.946509) + (xy 127.960718 64.119999) (xy 127.965 64.163478) (xy 127.964999 68.418532) (xy 127.960718 68.462001) (xy 127.964999 68.50547) + (xy 127.964999 68.505477) (xy 127.971849 68.575027) (xy 127.977804 68.635491) (xy 127.984935 68.658997) (xy 128.02841 68.802313) + (xy 128.110588 68.956059) (xy 128.221182 69.090818) (xy 128.254955 69.118535) (xy 128.565001 69.428582) (xy 128.565 75.979531) + (xy 128.560719 76.023) (xy 128.565 76.066469) (xy 128.565 76.066476) (xy 128.574265 76.160547) (xy 128.577805 76.19649) + (xy 128.580229 76.204479) (xy 128.628411 76.363312) (xy 128.710589 76.517058) (xy 128.821183 76.651817) (xy 128.854956 76.679534) + (xy 131.99547 79.820049) (xy 132.023183 79.853817) (xy 132.056951 79.88153) (xy 132.056953 79.881532) (xy 132.135435 79.945941) + (xy 132.157941 79.964411) (xy 132.19 79.981547) (xy 132.190001 80.815649) (xy 132.176185 80.798815) (xy 132.079494 80.719463) + (xy 131.96918 80.660498) (xy 131.849482 80.624188) (xy 131.725 80.611928) (xy 130.775 80.611928) (xy 130.650518 80.624188) + (xy 130.53082 80.660498) (xy 130.420506 80.719463) (xy 130.323815 80.798815) (xy 130.244463 80.895506) (xy 130.185498 81.00582) + (xy 130.162691 81.081003) (xy 130.08224 81.065) (xy 129.91776 81.065) (xy 129.75644 81.097089) (xy 129.652843 81.14) + (xy 129.57487 81.14) (xy 129.564502 81.10582) (xy 129.505537 80.995506) (xy 129.426185 80.898815) (xy 129.329494 80.819463) + (xy 129.21918 80.760498) (xy 129.099482 80.724188) (xy 128.975 80.711928) (xy 128.025 80.711928) (xy 127.900518 80.724188) + (xy 127.78082 80.760498) (xy 127.670506 80.819463) (xy 127.573815 80.898815) (xy 127.494463 80.995506) (xy 127.435498 81.10582) + (xy 127.399188 81.225518) (xy 127.386928 81.35) (xy 127.386928 82.65) (xy 127.399188 82.774482) (xy 127.435498 82.89418) + (xy 127.494463 83.004494) (xy 127.573815 83.101185) (xy 127.670506 83.180537) (xy 127.78082 83.239502) (xy 127.900518 83.275812) + (xy 128.025 83.288072) (xy 128.975 83.288072) (xy 129.099482 83.275812) (xy 129.21918 83.239502) (xy 129.329494 83.180537) + (xy 129.426185 83.101185) (xy 129.505537 83.004494) (xy 129.564502 82.89418) (xy 129.600812 82.774482) (xy 129.612087 82.66) + (xy 129.652843 82.66) (xy 129.75644 82.702911) (xy 129.91776 82.735) (xy 130.08224 82.735) (xy 130.162691 82.718997) + (xy 130.185498 82.79418) (xy 130.244463 82.904494) (xy 130.323815 83.001185) (xy 130.420506 83.080537) (xy 130.53082 83.139502) + (xy 130.650518 83.175812) (xy 130.775 83.188072) (xy 130.922352 83.188072) (xy 130.645425 83.464999) (xy 130.458464 83.464999) + (xy 130.414998 83.460718) (xy 130.371532 83.464999) (xy 130.371522 83.464999) (xy 130.241509 83.477804) (xy 130.074686 83.52841) + (xy 129.92094 83.610588) (xy 129.786182 83.721182) (xy 129.758467 83.754953) (xy 129.404956 84.108464) (xy 129.371183 84.136181) + (xy 129.260589 84.27094) (xy 129.234942 84.318923) (xy 129.21918 84.310498) (xy 129.099482 84.274188) (xy 128.975 84.261928) + (xy 128.025 84.261928) (xy 127.900518 84.274188) (xy 127.78082 84.310498) (xy 127.670506 84.369463) (xy 127.573815 84.448815) + (xy 127.494463 84.545506) (xy 127.435498 84.65582) (xy 127.399188 84.775518) (xy 127.386928 84.9) (xy 127.386928 86.2) + (xy 127.399188 86.324482) (xy 127.435498 86.44418) (xy 127.494463 86.554494) (xy 127.573815 86.651185) (xy 127.670506 86.730537) + (xy 127.681212 86.736259) (xy 127.665 86.81776) (xy 127.665 86.98224) (xy 127.697089 87.14356) (xy 127.760033 87.295521) + (xy 127.851413 87.432281) (xy 127.967719 87.548587) (xy 128.104479 87.639967) (xy 128.25644 87.702911) (xy 128.41776 87.735) + (xy 128.58224 87.735) (xy 128.74356 87.702911) (xy 128.895521 87.639967) (xy 129.032281 87.548587) (xy 129.115 87.465868) + (xy 129.115001 92.739294) (xy 128.959687 92.786409) (xy 128.805941 92.868587) (xy 128.805939 92.868588) (xy 128.80594 92.868588) + (xy 128.704953 92.951466) (xy 128.704951 92.951468) (xy 128.671183 92.979181) (xy 128.64347 93.012949) (xy 127.988072 93.668347) + (xy 127.988072 92.22) (xy 127.975812 92.095518) (xy 127.939502 91.97582) (xy 127.880537 91.865506) (xy 127.801185 91.768815) + (xy 127.704494 91.689463) (xy 127.59418 91.630498) (xy 127.474482 91.594188) (xy 127.35 91.581928) (xy 126.230748 91.581928) + (xy 126.362953 91.262756) (xy 126.445 90.850279) (xy 126.445 90.429721) (xy 126.362953 90.017244) (xy 126.202012 89.628698) + (xy 126.164985 89.573283) (xy 126.330779 89.504609) (xy 126.590379 89.33115) (xy 126.81115 89.110379) (xy 126.984609 88.850779) + (xy 127.104089 88.562327) (xy 127.165 88.256109) (xy 127.165 87.943891) (xy 127.104089 87.637673) (xy 126.984609 87.349221) + (xy 126.81115 87.089621) (xy 126.590379 86.86885) (xy 126.330779 86.695391) (xy 126.042327 86.575911) (xy 125.736109 86.515) + (xy 125.423891 86.515) (xy 125.117673 86.575911) (xy 125.023303 86.615) (xy 124.87299 86.615) (xy 125.961009 85.526982) + (xy 125.990001 85.503189) (xy 126.013795 85.474196) (xy 126.013799 85.474192) (xy 126.081049 85.392247) (xy 126.084974 85.387464) + (xy 126.155546 85.255435) (xy 126.199003 85.112174) (xy 126.21 85.000521) (xy 126.21 85.000512) (xy 126.213676 84.963189) + (xy 126.21 84.925866) (xy 126.21 83.847157) (xy 126.252911 83.74356) (xy 126.285 83.58224) (xy 126.285 83.41776) + (xy 126.252911 83.25644) (xy 126.21 83.152843) (xy 126.21 82.90251) (xy 126.213676 82.865187) (xy 126.21 82.827864) + (xy 126.21 82.827855) (xy 126.199003 82.716202) (xy 126.155546 82.572941) (xy 126.084974 82.440912) (xy 125.990001 82.325187) + (xy 125.961004 82.30139) (xy 124.873616 81.214002) (xy 124.849813 81.184999) (xy 124.734088 81.090026) (xy 124.602059 81.019454) + (xy 124.458798 80.975997) (xy 124.347145 80.965) (xy 124.347134 80.965) (xy 124.309812 80.961324) (xy 124.280618 80.964199) + (xy 124.230537 80.870506) (xy 124.151185 80.773815) (xy 124.054494 80.694463) (xy 123.94418 80.635498) (xy 123.824482 80.599188) + (xy 123.7 80.586928) (xy 122.96 80.586928) (xy 122.96 80.384877) (xy 122.963435 80.35) (xy 122.949727 80.210816) + (xy 122.909128 80.07698) (xy 122.8432 79.953637) (xy 122.754475 79.845525) (xy 122.646363 79.7568) (xy 122.52302 79.690872) + (xy 122.389184 79.650273) (xy 122.284877 79.64) (xy 122.25 79.636565) (xy 122.215123 79.64) (xy 121.628486 79.64) + (xy 121.635002 79.60724) (xy 121.635002 79.44276) (xy 121.602913 79.28144) (xy 121.560002 79.177843) (xy 121.560002 75.719348) + (xy 121.679017 75.838363) (xy 122.028698 76.072012) (xy 122.417244 76.232953) (xy 122.829721 76.315) (xy 123.250279 76.315) + (xy 123.662756 76.232953) (xy 124.051302 76.072012) (xy 124.400983 75.838363) (xy 124.540001 75.699345) (xy 124.54 76.252843) + (xy 124.497089 76.35644) (xy 124.465 76.51776) (xy 124.465 76.68224) (xy 124.497089 76.84356) (xy 124.560033 76.995521) + (xy 124.651413 77.132281) (xy 124.767719 77.248587) (xy 124.904479 77.339967) (xy 125.05644 77.402911) (xy 125.21776 77.435) + (xy 125.38224 77.435) (xy 125.54356 77.402911) (xy 125.695521 77.339967) (xy 125.832281 77.248587) (xy 125.948587 77.132281) + (xy 126.039967 76.995521) (xy 126.102911 76.84356) (xy 126.135 76.68224) (xy 126.135 76.51776) (xy 126.102911 76.35644) + (xy 126.06 76.252843) (xy 126.06 75.858072) (xy 127.35 75.858072) (xy 127.474482 75.845812) (xy 127.59418 75.809502) + (xy 127.704494 75.750537) (xy 127.801185 75.671185) (xy 127.880537 75.574494) (xy 127.939502 75.46418) (xy 127.975812 75.344482) + (xy 127.988072 75.22) (xy 127.988072 73.22) (xy 127.975812 73.095518) (xy 127.939502 72.97582) (xy 127.880537 72.865506) + (xy 127.801185 72.768815) (xy 127.704494 72.689463) (xy 127.59418 72.630498) (xy 127.474482 72.594188) (xy 127.35 72.581928) + (xy 126.230748 72.581928) (xy 126.362953 72.262756) (xy 126.445 71.850279) (xy 126.445 71.429721) (xy 126.362953 71.017244) + (xy 126.202012 70.628698) (xy 126.164985 70.573283) (xy 126.330779 70.504609) (xy 126.590379 70.33115) (xy 126.81115 70.110379) + (xy 126.984609 69.850779) (xy 127.104089 69.562327) (xy 127.165 69.256109) (xy 127.165 68.943891) (xy 127.104089 68.637673) + (xy 126.984609 68.349221) (xy 126.81115 68.089621) (xy 126.590379 67.86885) (xy 126.330779 67.695391) (xy 126.042327 67.575911) + (xy 125.736109 67.515) (xy 125.423891 67.515) (xy 125.117673 67.575911) (xy 125.023303 67.615) (xy 124.85374 67.615) + (xy 124.566842 67.672068) (xy 124.296589 67.78401) (xy 124.053368 67.946525) (xy 123.846525 68.153368) (xy 123.68401 68.396589) + (xy 123.635001 68.514908) (xy 123.635001 66.319933) (xy 123.663588 66.277149) (xy 123.726532 66.125188) (xy 123.758621 65.963868) + (xy 123.758621 65.799388) (xy 123.726532 65.638068) (xy 123.715544 65.611541) (xy 123.824482 65.600812) (xy 123.94418 65.564502) + (xy 124.054494 65.505537) (xy 124.151185 65.426185) (xy 124.230537 65.329494) (xy 124.289502 65.21918) (xy 124.325812 65.099482) + (xy 124.338072 64.975) (xy 124.336997 64.9) (xy 125.686928 64.9) (xy 125.686928 66.2) (xy 125.699188 66.324482) + (xy 125.735498 66.44418) (xy 125.794463 66.554494) (xy 125.873815 66.651185) (xy 125.970506 66.730537) (xy 125.975095 66.73299) + (xy 125.997089 66.84356) (xy 126.060033 66.995521) (xy 126.151413 67.132281) (xy 126.267719 67.248587) (xy 126.404479 67.339967) + (xy 126.55644 67.402911) (xy 126.71776 67.435) (xy 126.88224 67.435) (xy 127.04356 67.402911) (xy 127.195521 67.339967) + (xy 127.332281 67.248587) (xy 127.448587 67.132281) (xy 127.539967 66.995521) (xy 127.602911 66.84356) (xy 127.624905 66.73299) + (xy 127.629494 66.730537) (xy 127.726185 66.651185) (xy 127.805537 66.554494) (xy 127.864502 66.44418) (xy 127.900812 66.324482) + (xy 127.913072 66.2) (xy 127.913072 64.9) (xy 127.900812 64.775518) (xy 127.864502 64.65582) (xy 127.805537 64.545506) + (xy 127.726185 64.448815) (xy 127.629494 64.369463) (xy 127.51918 64.310498) (xy 127.399482 64.274188) (xy 127.275 64.261928) + (xy 126.325 64.261928) (xy 126.200518 64.274188) (xy 126.08082 64.310498) (xy 125.970506 64.369463) (xy 125.873815 64.448815) + (xy 125.794463 64.545506) (xy 125.735498 64.65582) (xy 125.699188 64.775518) (xy 125.686928 64.9) (xy 124.336997 64.9) + (xy 124.335 64.76075) (xy 124.17625 64.602) (xy 123.027 64.602) (xy 123.027 64.622) (xy 122.96 64.622) + (xy 122.96 64.328) (xy 123.027 64.328) (xy 123.027 64.348) (xy 124.17625 64.348) (xy 124.296264 64.227986) + (xy 124.35644 64.252911) (xy 124.51776 64.285) (xy 124.68224 64.285) (xy 124.84356 64.252911) (xy 124.995521 64.189967) + (xy 125.132281 64.098587) (xy 125.248587 63.982281) (xy 125.339967 63.845521) (xy 125.402911 63.69356) (xy 125.435 63.53224) + (xy 125.435 63.36776) (xy 125.402911 63.20644) (xy 125.339967 63.054479) (xy 125.248587 62.917719) (xy 125.132281 62.801413) + (xy 124.995521 62.710033) (xy 124.891923 62.667122) (xy 124.513803 62.289002) (xy 124.490001 62.259999) (xy 124.374276 62.165026) + (xy 124.329825 62.141266) (xy 124.325812 62.100518) (xy 124.289502 61.98082) (xy 124.230537 61.870506) (xy 124.151185 61.773815) + (xy 124.054494 61.694463) (xy 123.94418 61.635498) (xy 123.824482 61.599188) (xy 123.7 61.586928) (xy 122.96 61.586928) + (xy 122.96 61.513072) (xy 123.7 61.513072) (xy 123.824482 61.500812) (xy 123.94418 61.464502) (xy 124.054494 61.405537) + (xy 124.151185 61.326185) (xy 124.230537 61.229494) (xy 124.289502 61.11918) (xy 124.325812 60.999482) (xy 124.338072 60.875) + (xy 124.338072 60.836729) (xy 124.891923 60.282878) (xy 124.995521 60.239967) (xy 125.132281 60.148587) (xy 125.248587 60.032281) + (xy 125.339967 59.895521) (xy 125.402911 59.74356) (xy 125.435 59.58224) (xy 125.435 59.41776) (xy 125.402911 59.25644) + (xy 125.339967 59.104479) (xy 125.248587 58.967719) (xy 125.132281 58.851413) (xy 124.995521 58.760033) (xy 124.84356 58.697089) + (xy 124.68224 58.665) (xy 124.51776 58.665) (xy 124.35644 58.697089) (xy 124.204479 58.760033) (xy 124.192372 58.768122) + (xy 124.17625 58.752) (xy 122.827 58.752) (xy 122.827 58.772) (xy 122.573 58.772) (xy 122.573 58.752) + (xy 121.22375 58.752) (xy 121.065 58.91075) (xy 121.061928 59.125) (xy 121.074188 59.249482) (xy 121.110498 59.36918) + (xy 121.169463 59.479494) (xy 121.186292 59.5) (xy 121.169463 59.520506) (xy 121.110498 59.63082) (xy 121.074188 59.750518) + (xy 121.061928 59.875) (xy 121.061928 60.64) (xy 119.938072 60.64) (xy 119.938072 59.875) (xy 119.925812 59.750518) + (xy 119.889502 59.63082) (xy 119.830537 59.520506) (xy 119.813708 59.5) (xy 119.830537 59.479494) (xy 119.889502 59.36918) + (xy 119.925812 59.249482) (xy 119.938072 59.125) (xy 119.938072 58.125) (xy 119.925812 58.000518) (xy 119.889502 57.88082) + (xy 119.830537 57.770506) (xy 119.751185 57.673815) (xy 119.740445 57.665001) (xy 121.259555 57.665001) (xy 121.248815 57.673815) + (xy 121.169463 57.770506) (xy 121.110498 57.88082) (xy 121.074188 58.000518) (xy 121.061928 58.125) (xy 121.065 58.33925) + (xy 121.22375 58.498) (xy 122.573 58.498) (xy 122.573 58.478) (xy 122.827 58.478) (xy 122.827 58.498) + (xy 124.17625 58.498) (xy 124.335 58.33925) (xy 124.338072 58.125) (xy 124.325812 58.000518) (xy 124.289502 57.88082) + (xy 124.230537 57.770506) (xy 124.151185 57.673815) (xy 124.140445 57.665001) (xy 124.377677 57.665001) (xy 124.414999 57.668677) + (xy 124.452321 57.665001) (xy 124.452332 57.665001) (xy 124.563985 57.654004) (xy 124.707246 57.610547) (xy 124.839275 57.539975) + (xy 124.955 57.445002) (xy 124.978803 57.415998) (xy 125.636729 56.758072) (xy 127.015 56.758072) (xy 127.015 57.293997) + (xy 127.129712 57.870692) (xy 127.354727 58.413928) (xy 127.681399 58.902826) (xy 128.097174 59.318601) (xy 128.586072 59.645273) + (xy 129.129308 59.870288) (xy 129.706003 59.985) (xy 130.293997 59.985) (xy 130.870692 59.870288) (xy 131.413928 59.645273) + (xy 131.902826 59.318601) (xy 132.318601 58.902826) (xy 132.645273 58.413928) (xy 132.870288 57.870692) (xy 132.985 57.293997) + (xy 132.985 56.706003) (xy 132.930516 56.432095) + ) + ) + (filled_polygon + (pts + (xy 219.79 77.860444) (xy 219.790001 78.127832) (xy 219.747089 78.23143) (xy 219.715 78.39275) (xy 219.715 78.55723) + (xy 219.747089 78.71855) (xy 219.810033 78.870511) (xy 219.901413 79.007271) (xy 220.017719 79.123577) (xy 220.154479 79.214957) + (xy 220.258078 79.257869) (xy 221.295002 80.294794) (xy 221.295001 81.017667) (xy 221.295001 81.342333) (xy 221.295002 81.342343) + (xy 221.295001 87.842333) (xy 221.295002 87.842343) (xy 221.295002 88.997729) (xy 221.242327 88.975911) (xy 220.936109 88.915) + (xy 220.623891 88.915) (xy 220.317673 88.975911) (xy 220.223303 89.015) (xy 220.05374 89.015) (xy 219.766842 89.072068) + (xy 219.496589 89.18401) (xy 219.253368 89.346525) (xy 219.046525 89.553368) (xy 218.88401 89.796589) (xy 218.772068 90.066842) + (xy 218.715 90.35374) (xy 218.715 90.64626) (xy 218.772068 90.933158) (xy 218.807988 91.019876) (xy 218.498698 91.147988) + (xy 218.276252 91.296622) (xy 218.281817 91.283186) (xy 218.385 90.764449) (xy 218.385 90.235551) (xy 218.281817 89.716814) + (xy 218.079417 89.228175) (xy 217.785576 88.788412) (xy 217.411588 88.414424) (xy 216.971825 88.120583) (xy 216.679503 87.9995) + (xy 217.415123 87.9995) (xy 217.45 88.002935) (xy 217.484877 87.9995) (xy 217.589184 87.989227) (xy 217.72302 87.948628) + (xy 217.846363 87.8827) (xy 217.954475 87.793975) (xy 218.0432 87.685863) (xy 218.109128 87.56252) (xy 218.149727 87.428684) + (xy 218.163435 87.2895) (xy 218.16 87.254623) (xy 218.16 87.01) (xy 218.227002 87.01) (xy 218.227002 86.851252) + (xy 218.38575 87.01) (xy 218.9 87.013072) (xy 219.024482 87.000812) (xy 219.14418 86.964502) (xy 219.254494 86.905537) + (xy 219.351185 86.826185) (xy 219.430537 86.729494) (xy 219.489502 86.61918) (xy 219.525812 86.499482) (xy 219.538072 86.375) + (xy 219.535 86.16075) (xy 219.37625 86.002) (xy 218.227 86.002) (xy 218.227 86.022) (xy 218.16 86.022) + (xy 218.16 85.728) (xy 218.227 85.728) (xy 218.227 85.748) (xy 219.37625 85.748) (xy 219.535 85.58925) + (xy 219.535438 85.558679) (xy 219.66776 85.585) (xy 219.83224 85.585) (xy 219.99356 85.552911) (xy 220.145521 85.489967) + (xy 220.282281 85.398587) (xy 220.398587 85.282281) (xy 220.489967 85.145521) (xy 220.552911 84.99356) (xy 220.585 84.83224) + (xy 220.585 84.66776) (xy 220.552911 84.50644) (xy 220.489967 84.354479) (xy 220.398587 84.217719) (xy 220.282281 84.101413) + (xy 220.145521 84.010033) (xy 220.04363 83.967829) (xy 219.765803 83.690002) (xy 219.742001 83.660999) (xy 219.626276 83.566026) + (xy 219.52704 83.512982) (xy 219.525812 83.500518) (xy 219.489502 83.38082) (xy 219.430537 83.270506) (xy 219.351185 83.173815) + (xy 219.254494 83.094463) (xy 219.14418 83.035498) (xy 219.024482 82.999188) (xy 218.9 82.986928) (xy 218.86 82.986928) + (xy 218.86 80.112312) (xy 218.863676 80.074989) (xy 218.86 80.037666) (xy 218.86 80.037657) (xy 218.849003 79.926004) + (xy 218.805546 79.782743) (xy 218.734974 79.650714) (xy 218.711001 79.621503) (xy 218.663799 79.563986) (xy 218.663795 79.563982) + (xy 218.640001 79.534989) (xy 218.611008 79.511195) (xy 217.473029 78.373217) (xy 217.617244 78.432953) (xy 218.029721 78.515) + (xy 218.450279 78.515) (xy 218.862756 78.432953) (xy 219.251302 78.272012) (xy 219.600983 78.038363) (xy 219.784998 77.854348) + ) + ) + (filled_polygon + (pts + (xy 114.197083 83.55644) (xy 114.164994 83.71776) (xy 114.164994 83.88224) (xy 114.197083 84.04356) (xy 114.260027 84.195521) + (xy 114.351407 84.332281) (xy 114.467713 84.448587) (xy 114.604473 84.539967) (xy 114.756434 84.602911) (xy 114.917754 84.635) + (xy 115.082234 84.635) (xy 115.243554 84.602911) (xy 115.395515 84.539967) (xy 115.532275 84.448587) (xy 115.648581 84.332281) + (xy 115.739961 84.195521) (xy 115.78673 84.082611) (xy 115.85594 84.13941) (xy 116.009686 84.221588) (xy 116.176509 84.272194) + (xy 116.349999 84.289281) (xy 116.523489 84.272194) (xy 116.690313 84.221588) (xy 116.70831 84.211968) (xy 116.710498 84.21918) + (xy 116.769463 84.329494) (xy 116.848815 84.426185) (xy 116.945506 84.505537) (xy 117.05582 84.564502) (xy 117.175518 84.600812) + (xy 117.3 84.613072) (xy 118.04 84.613072) (xy 118.04 84.815123) (xy 118.036565 84.85) (xy 118.050273 84.989184) + (xy 118.090872 85.12302) (xy 118.1568 85.246363) (xy 118.245525 85.354475) (xy 118.338699 85.430941) (xy 118.353637 85.4432) + (xy 118.47698 85.509128) (xy 118.610816 85.549727) (xy 118.75 85.563435) (xy 118.784877 85.56) (xy 119.615858 85.56) + (xy 119.228175 85.720583) (xy 118.788412 86.014424) (xy 118.414424 86.388412) (xy 118.120583 86.828175) (xy 118.087914 86.907046) + (xy 118.032281 86.851413) (xy 117.895521 86.760033) (xy 117.74356 86.697089) (xy 117.58224 86.665) (xy 117.41776 86.665) + (xy 117.25644 86.697089) (xy 117.104479 86.760033) (xy 116.967719 86.851413) (xy 116.902257 86.916875) (xy 116.703411 86.78401) + (xy 116.433158 86.672068) (xy 116.14626 86.615) (xy 115.976697 86.615) (xy 115.882327 86.575911) (xy 115.576109 86.515) + (xy 115.263891 86.515) (xy 114.957673 86.575911) (xy 114.669221 86.695391) (xy 114.409621 86.86885) (xy 114.18885 87.089621) + (xy 114.015391 87.349221) (xy 113.895911 87.637673) (xy 113.835 87.943891) (xy 113.835 88.256109) (xy 113.895911 88.562327) + (xy 114.015391 88.850779) (xy 114.143113 89.041928) (xy 112.35 89.041928) (xy 112.225518 89.054188) (xy 112.10582 89.090498) + (xy 111.995506 89.149463) (xy 111.898815 89.228815) (xy 111.819463 89.325506) (xy 111.760498 89.43582) (xy 111.735542 89.518089) + (xy 111.735009 89.512679) (xy 111.735009 86.062505) (xy 111.738616 86.025883) (xy 111.826413 86.157281) (xy 111.942719 86.273587) + (xy 112.079479 86.364967) (xy 112.23144 86.427911) (xy 112.39276 86.46) (xy 112.55724 86.46) (xy 112.71856 86.427911) + (xy 112.870521 86.364967) (xy 113.007281 86.273587) (xy 113.123587 86.157281) (xy 113.214967 86.020521) (xy 113.277911 85.86856) + (xy 113.31 85.70724) (xy 113.31 85.54276) (xy 113.282 85.401996) (xy 113.282 84.228272) (xy 113.33768 84.211382) + (xy 113.447994 84.152417) (xy 113.544685 84.073065) (xy 113.583493 84.025777) (xy 113.635747 84.009926) (xy 113.767776 83.939354) + (xy 113.883501 83.844381) (xy 113.907303 83.815378) (xy 114.218891 83.50379) + ) + ) + (filled_polygon + (pts + (xy 186.490001 86.335196) (xy 184.964001 87.861198) (xy 184.934998 87.885) (xy 184.889857 87.940005) (xy 184.840025 88.000725) + (xy 184.781908 88.109454) (xy 184.769453 88.132755) (xy 184.725996 88.276016) (xy 184.714999 88.387669) (xy 184.714999 88.387679) + (xy 184.711323 88.425001) (xy 184.714999 88.462323) (xy 184.714999 89.141626) (xy 184.69418 89.130498) (xy 184.574482 89.094188) + (xy 184.45 89.081928) (xy 184.06 89.081928) (xy 184.06 87.181803) (xy 184.466005 86.775799) (xy 184.495002 86.752002) + (xy 184.589975 86.636277) (xy 184.660547 86.504248) (xy 184.704004 86.360987) (xy 184.715001 86.249334) (xy 184.715001 86.249325) + (xy 184.718677 86.212002) (xy 184.715001 86.174679) (xy 184.715001 84.142323) (xy 184.718677 84.105) (xy 184.715001 84.067677) + (xy 184.715001 84.067668) (xy 184.704004 83.956015) (xy 184.660547 83.812754) (xy 184.589975 83.680725) (xy 184.577562 83.6656) + (xy 185.682443 83.6656) (xy 185.78604 83.708511) (xy 185.94736 83.7406) (xy 186.11184 83.7406) (xy 186.27316 83.708511) + (xy 186.425121 83.645567) (xy 186.490001 83.602216) + ) + ) + (filled_polygon + (pts + (xy 124.682049 83.172039) (xy 124.647089 83.25644) (xy 124.615 83.41776) (xy 124.615 83.58224) (xy 124.647089 83.74356) + (xy 124.690001 83.847159) (xy 124.69 84.648385) (xy 123.313997 86.02439) (xy 123.284999 86.048188) (xy 123.261201 86.077186) + (xy 123.2612 86.077187) (xy 123.190025 86.163913) (xy 123.119453 86.295943) (xy 123.097238 86.36918) (xy 123.075997 86.439203) + (xy 123.065844 86.542283) (xy 123.061323 86.588189) (xy 123.065 86.625521) (xy 123.065 87.276213) (xy 122.879417 86.828175) + (xy 122.585576 86.388412) (xy 122.211588 86.014424) (xy 121.771825 85.720583) (xy 121.384142 85.56) (xy 122.215123 85.56) + (xy 122.25 85.563435) (xy 122.284877 85.56) (xy 122.389184 85.549727) (xy 122.52302 85.509128) (xy 122.646363 85.4432) + (xy 122.754475 85.354475) (xy 122.8432 85.246363) (xy 122.909128 85.12302) (xy 122.949727 84.989184) (xy 122.963435 84.85) + (xy 122.96 84.815123) (xy 122.96 84.61) (xy 123.027002 84.61) (xy 123.027002 84.451252) (xy 123.18575 84.61) + (xy 123.7 84.613072) (xy 123.824482 84.600812) (xy 123.94418 84.564502) (xy 124.054494 84.505537) (xy 124.151185 84.426185) + (xy 124.230537 84.329494) (xy 124.289502 84.21918) (xy 124.325812 84.099482) (xy 124.338072 83.975) (xy 124.335 83.76075) + (xy 124.17625 83.602) (xy 123.027 83.602) (xy 123.027 83.622) (xy 122.96 83.622) (xy 122.96 83.328) + (xy 123.027 83.328) (xy 123.027 83.348) (xy 124.17625 83.348) (xy 124.335 83.18925) (xy 124.338072 82.975) + (xy 124.325812 82.850518) (xy 124.310695 82.800685) + ) + ) + (filled_polygon + (pts + (xy 188.019463 75.234494) (xy 188.098815 75.331185) (xy 188.195506 75.410537) (xy 188.30582 75.469502) (xy 188.425518 75.505812) + (xy 188.55 75.518072) (xy 190.85 75.518072) (xy 190.974482 75.505812) (xy 191.09418 75.469502) (xy 191.204494 75.410537) + (xy 191.301185 75.331185) (xy 191.328525 75.297872) (xy 191.529017 75.498364) (xy 191.878698 75.732013) (xy 192.094302 75.821319) + (xy 192.025 76.169721) (xy 192.025 76.590279) (xy 192.107047 77.002756) (xy 192.267988 77.391302) (xy 192.501637 77.740983) + (xy 192.650654 77.89) (xy 191.914802 77.89) (xy 191.632879 77.608077) (xy 191.589967 77.504479) (xy 191.498587 77.367719) + (xy 191.382281 77.251413) (xy 191.245521 77.160033) (xy 191.09356 77.097089) (xy 190.93224 77.065) (xy 190.76776 77.065) + (xy 190.60644 77.097089) (xy 190.454479 77.160033) (xy 190.317719 77.251413) (xy 190.201413 77.367719) (xy 190.110033 77.504479) + (xy 190.047089 77.65644) (xy 190.015 77.81776) (xy 190.015 77.98224) (xy 190.047089 78.14356) (xy 190.110033 78.295521) + (xy 190.201413 78.432281) (xy 190.317719 78.548587) (xy 190.454479 78.639967) (xy 190.558077 78.682879) (xy 191.036201 79.161002) + (xy 191.059999 79.190001) (xy 191.175724 79.284974) (xy 191.307753 79.355546) (xy 191.451014 79.399003) (xy 191.562667 79.41) + (xy 191.562676 79.41) (xy 191.599999 79.413676) (xy 191.637322 79.41) (xy 192.857746 79.41) (xy 192.817122 79.508076) + (xy 191.239003 81.086196) (xy 191.209999 81.109999) (xy 191.165686 81.163995) (xy 191.115026 81.225724) (xy 191.071446 81.307256) + (xy 191.044454 81.357754) (xy 191.000997 81.501015) (xy 190.99 81.612668) (xy 190.99 81.612678) (xy 190.986324 81.65) + (xy 190.99 81.687323) (xy 190.990001 84.752841) (xy 190.947089 84.85644) (xy 190.915 85.01776) (xy 190.915 85.18224) + (xy 190.947089 85.34356) (xy 191.010033 85.495521) (xy 191.101413 85.632281) (xy 191.217719 85.748587) (xy 191.354479 85.839967) + (xy 191.458077 85.882879) (xy 191.961201 86.386002) (xy 191.984999 86.415001) (xy 192.013997 86.438799) (xy 192.100724 86.509974) + (xy 192.232753 86.580546) (xy 192.376014 86.624003) (xy 192.525 86.638677) (xy 192.562333 86.635) (xy 192.918954 86.635) + (xy 192.969463 86.729494) (xy 192.980547 86.743) (xy 189.613072 86.743) (xy 189.613072 86.35) (xy 189.600812 86.225518) + (xy 189.564502 86.10582) (xy 189.505537 85.995506) (xy 189.426185 85.898815) (xy 189.329494 85.819463) (xy 189.21918 85.760498) + (xy 189.099482 85.724188) (xy 188.975 85.711928) (xy 188.025 85.711928) (xy 188.01 85.713405) (xy 188.01 75.21679) + ) + ) + (filled_polygon + (pts + (xy 181.64 73.502843) (xy 181.597089 73.60644) (xy 181.565 73.76776) (xy 181.565 73.93224) (xy 181.597089 74.09356) + (xy 181.660033 74.245521) (xy 181.751413 74.382281) (xy 181.867719 74.498587) (xy 182.004479 74.589967) (xy 182.108077 74.632879) + (xy 182.490001 75.014803) (xy 182.49 81.456867) (xy 182.49 81.456868) (xy 182.490001 83.362668) (xy 182.486324 83.4) + (xy 182.490001 83.437333) (xy 182.500998 83.548986) (xy 182.505641 83.564293) (xy 182.544454 83.692246) (xy 182.615026 83.824276) + (xy 182.684355 83.908753) (xy 182.71 83.940001) (xy 182.738998 83.963799) (xy 182.790199 84.015) (xy 182.523891 84.015) + (xy 182.217673 84.075911) (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) + (xy 181.153368 84.446525) (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) + (xy 180.615 85.74626) (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) + (xy 180.181817 86.383186) (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) + (xy 179.685576 83.888412) (xy 179.311588 83.514424) (xy 178.871825 83.220583) (xy 178.725564 83.16) (xy 179.315123 83.16) + (xy 179.35 83.163435) (xy 179.384877 83.16) (xy 179.396219 83.158883) (xy 179.489184 83.149727) (xy 179.62302 83.109128) + (xy 179.746363 83.0432) (xy 179.854475 82.954475) (xy 179.9432 82.846363) (xy 180.009128 82.72302) (xy 180.049727 82.589184) + (xy 180.06 82.484877) (xy 180.06 82.484876) (xy 180.063435 82.45) (xy 180.06 82.415123) (xy 180.06 82.11) + (xy 180.127002 82.11) (xy 180.127002 81.951252) (xy 180.28575 82.11) (xy 180.8 82.113072) (xy 180.924482 82.100812) + (xy 181.04418 82.064502) (xy 181.154494 82.005537) (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) + (xy 181.425812 81.599482) (xy 181.438072 81.475) (xy 181.435 81.26075) (xy 181.276252 81.102002) (xy 181.354245 81.102002) + (xy 181.35644 81.102911) (xy 181.51776 81.135) (xy 181.68224 81.135) (xy 181.84356 81.102911) (xy 181.995521 81.039967) + (xy 182.132281 80.948587) (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) + (xy 182.435 80.21776) (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) + (xy 181.995521 79.560033) (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.631802 79.465) (xy 181.438072 79.27127) + (xy 181.438072 78.725) (xy 181.425812 78.600518) (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) + (xy 181.154494 78.194463) (xy 181.04418 78.135498) (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.76 78.086928) + (xy 180.76 77.287322) (xy 180.763676 77.249999) (xy 180.76 77.212676) (xy 180.76 77.212667) (xy 180.749003 77.101014) + (xy 180.705546 76.957753) (xy 180.634974 76.825724) (xy 180.540001 76.709999) (xy 180.511003 76.686201) (xy 179.074999 75.250198) + (xy 179.074999 73.436132) (xy 179.128698 73.472012) (xy 179.517244 73.632953) (xy 179.929721 73.715) (xy 180.350279 73.715) + (xy 180.762756 73.632953) (xy 181.151302 73.472012) (xy 181.500983 73.238363) (xy 181.640001 73.099345) + ) + ) + (filled_polygon + (pts + (xy 143.54 73.552843) (xy 143.497089 73.65644) (xy 143.465 73.81776) (xy 143.465 73.98224) (xy 143.497089 74.14356) + (xy 143.560033 74.295521) (xy 143.651413 74.432281) (xy 143.767719 74.548587) (xy 143.904479 74.639967) (xy 144.008078 74.682879) + (xy 145.095001 75.769803) (xy 145.095002 84.097729) (xy 145.042327 84.075911) (xy 144.736109 84.015) (xy 144.423891 84.015) + (xy 144.117673 84.075911) (xy 144.023303 84.115) (xy 143.85374 84.115) (xy 143.566842 84.172068) (xy 143.296589 84.28401) + (xy 143.053368 84.446525) (xy 142.846525 84.653368) (xy 142.68401 84.896589) (xy 142.572068 85.166842) (xy 142.515 85.45374) + (xy 142.515 85.74626) (xy 142.572068 86.033158) (xy 142.607988 86.119876) (xy 142.298698 86.247988) (xy 142.076252 86.396622) + (xy 142.081817 86.383186) (xy 142.185 85.864449) (xy 142.185 85.335551) (xy 142.081817 84.816814) (xy 141.879417 84.328175) + (xy 141.585576 83.888412) (xy 141.211588 83.514424) (xy 140.771825 83.220583) (xy 140.625564 83.16) (xy 141.215123 83.16) + (xy 141.25 83.163435) (xy 141.284877 83.16) (xy 141.296219 83.158883) (xy 141.389184 83.149727) (xy 141.52302 83.109128) + (xy 141.646363 83.0432) (xy 141.754475 82.954475) (xy 141.8432 82.846363) (xy 141.909128 82.72302) (xy 141.949727 82.589184) + (xy 141.96 82.484877) (xy 141.96 82.484876) (xy 141.963435 82.45) (xy 141.96 82.415123) (xy 141.96 82.11) + (xy 142.027002 82.11) (xy 142.027002 81.951252) (xy 142.18575 82.11) (xy 142.7 82.113072) (xy 142.824482 82.100812) + (xy 142.94418 82.064502) (xy 143.054494 82.005537) (xy 143.151185 81.926185) (xy 143.230537 81.829494) (xy 143.289502 81.71918) + (xy 143.325812 81.599482) (xy 143.338072 81.475) (xy 143.335 81.26075) (xy 143.17625 81.102) (xy 142.027 81.102) + (xy 142.027 81.122) (xy 141.96 81.122) (xy 141.96 80.828) (xy 142.027 80.828) (xy 142.027 80.848) + (xy 143.17625 80.848) (xy 143.335 80.68925) (xy 143.335227 80.673414) (xy 143.40644 80.702911) (xy 143.56776 80.735) + (xy 143.73224 80.735) (xy 143.89356 80.702911) (xy 144.045521 80.639967) (xy 144.182281 80.548587) (xy 144.298587 80.432281) + (xy 144.389967 80.295521) (xy 144.452911 80.14356) (xy 144.485 79.98224) (xy 144.485 79.81776) (xy 144.452911 79.65644) + (xy 144.403303 79.536676) (xy 144.399003 79.493014) (xy 144.355546 79.349753) (xy 144.284974 79.217724) (xy 144.262222 79.190001) + (xy 144.213799 79.130996) (xy 144.213795 79.130992) (xy 144.190001 79.101999) (xy 144.161009 79.078206) (xy 143.696803 78.614002) + (xy 143.673001 78.584999) (xy 143.557276 78.490026) (xy 143.425247 78.419454) (xy 143.281986 78.375997) (xy 143.230776 78.370953) + (xy 143.230537 78.370506) (xy 143.151185 78.273815) (xy 143.054494 78.194463) (xy 142.94418 78.135498) (xy 142.824482 78.099188) + (xy 142.7 78.086928) (xy 142.66 78.086928) (xy 142.66 76.687322) (xy 142.663676 76.649999) (xy 142.66 76.612676) + (xy 142.66 76.612667) (xy 142.649003 76.501014) (xy 142.605546 76.357753) (xy 142.534974 76.225724) (xy 142.440001 76.109999) + (xy 142.411004 76.086202) (xy 140.974999 74.650198) (xy 140.974999 73.536132) (xy 141.028698 73.572012) (xy 141.417244 73.732953) + (xy 141.829721 73.815) (xy 142.250279 73.815) (xy 142.662756 73.732953) (xy 143.051302 73.572012) (xy 143.400983 73.338363) + (xy 143.540001 73.199345) + ) + ) + (filled_polygon + (pts + (xy 187.149188 65.774482) (xy 187.185498 65.89418) (xy 187.244463 66.004494) (xy 187.323815 66.101185) (xy 187.420506 66.180537) + (xy 187.53082 66.239502) (xy 187.650518 66.275812) (xy 187.687113 66.279416) (xy 187.573723 66.340025) (xy 187.457998 66.434998) + (xy 187.4342 66.463997) (xy 186.990756 66.907441) (xy 186.957753 66.917452) (xy 186.825724 66.988024) (xy 186.709999 67.082997) + (xy 186.615026 67.198723) (xy 186.544454 67.330752) (xy 186.500997 67.474013) (xy 186.49 67.585666) (xy 186.49 67.685676) + (xy 186.486324 67.722998) (xy 186.49 67.76032) (xy 186.490001 82.208984) (xy 186.425121 82.165633) (xy 186.27316 82.102689) + (xy 186.11184 82.0706) (xy 185.94736 82.0706) (xy 185.78604 82.102689) (xy 185.682443 82.1456) (xy 184.497157 82.1456) + (xy 184.39356 82.102689) (xy 184.23224 82.0706) (xy 184.06776 82.0706) (xy 184.01 82.082089) (xy 184.01 74.737333) + (xy 184.013677 74.7) (xy 183.999003 74.551014) (xy 183.955546 74.407753) (xy 183.884974 74.275724) (xy 183.842826 74.224366) + (xy 183.790001 74.159999) (xy 183.761003 74.136201) (xy 183.182879 73.558077) (xy 183.16 73.502843) (xy 183.16 73.258072) + (xy 184.45 73.258072) (xy 184.574482 73.245812) (xy 184.69418 73.209502) (xy 184.804494 73.150537) (xy 184.901185 73.071185) + (xy 184.980537 72.974494) (xy 185.039502 72.86418) (xy 185.075812 72.744482) (xy 185.088072 72.62) (xy 185.088072 70.62) + (xy 185.075812 70.495518) (xy 185.039502 70.37582) (xy 184.980537 70.265506) (xy 184.901185 70.168815) (xy 184.804494 70.089463) + (xy 184.715001 70.041627) (xy 184.715001 65.76) (xy 187.147762 65.76) + ) + ) + (filled_polygon + (pts + (xy 180.127 80.848) (xy 180.147 80.848) (xy 180.147 81.102) (xy 180.127 81.102) (xy 180.127 81.122) + (xy 180.06 81.122) (xy 180.06 80.828) (xy 180.127 80.828) + ) + ) + (filled_polygon + (pts + (xy 105.381186 68.948002) (xy 105.410184 68.9718) (xy 105.49691 69.042975) (xy 105.588378 69.091866) (xy 105.62894 69.113547) + (xy 105.772201 69.157004) (xy 105.883854 69.168001) (xy 105.883864 69.168001) (xy 105.921187 69.171677) (xy 105.95851 69.168001) + (xy 106.023 69.168001) (xy 106.023 69.307592) (xy 106.076686 69.57749) (xy 106.181995 69.831727) (xy 106.33488 70.060535) + (xy 106.529465 70.25512) (xy 106.758273 70.408005) (xy 107.01251 70.513314) (xy 107.282408 70.567) (xy 107.334478 70.567) + (xy 107.375501 70.773235) (xy 107.48081 71.027472) (xy 107.633695 71.25628) (xy 107.82828 71.450865) (xy 108.057088 71.60375) + (xy 108.311325 71.709059) (xy 108.581223 71.762745) (xy 108.856407 71.762745) (xy 108.990003 71.736171) (xy 108.990003 74.693303) + (xy 108.90618 74.648498) (xy 108.786482 74.612188) (xy 108.662 74.599928) (xy 108.18575 74.603) (xy 108.027 74.76175) + (xy 108.027 75.873) (xy 108.047 75.873) (xy 108.047 76.127) (xy 108.027 76.127) (xy 108.027 76.147) + (xy 107.773 76.147) (xy 107.773 76.127) (xy 106.66175 76.127) (xy 106.503 76.28575) (xy 106.499928 76.762) + (xy 106.512188 76.886482) (xy 106.548498 77.00618) (xy 106.607463 77.116494) (xy 106.686815 77.213185) (xy 106.783506 77.292537) + (xy 106.797468 77.3) (xy 106.783506 77.307463) (xy 106.686815 77.386815) (xy 106.607463 77.483506) (xy 106.548498 77.59382) + (xy 106.512188 77.713518) (xy 106.499928 77.838) (xy 106.499928 79.362) (xy 106.512188 79.486482) (xy 106.548498 79.60618) + (xy 106.607463 79.716494) (xy 106.686815 79.813185) (xy 106.731674 79.85) (xy 106.686815 79.886815) (xy 106.664989 79.91341) + (xy 105.385 78.633422) (xy 105.385 76.543477) (xy 105.389282 76.5) (xy 105.372195 76.32651) (xy 105.321589 76.159687) + (xy 105.239411 76.005941) (xy 105.128817 75.871183) (xy 104.994059 75.760589) (xy 104.988077 75.757392) (xy 105.170057 75.635797) + (xy 105.355797 75.450057) (xy 105.497488 75.238) (xy 106.499928 75.238) (xy 106.503 75.71425) (xy 106.66175 75.873) + (xy 107.773 75.873) (xy 107.773 74.76175) (xy 107.61425 74.603) (xy 107.138 74.599928) (xy 107.013518 74.612188) + (xy 106.89382 74.648498) (xy 106.783506 74.707463) (xy 106.686815 74.786815) (xy 106.607463 74.883506) (xy 106.548498 74.99382) + (xy 106.512188 75.113518) (xy 106.499928 75.238) (xy 105.497488 75.238) (xy 105.501732 75.231649) (xy 105.602254 74.988968) + (xy 105.6535 74.731338) (xy 105.6535 74.468662) (xy 105.602254 74.211032) (xy 105.501732 73.968351) (xy 105.355797 73.749943) + (xy 105.170057 73.564203) (xy 105.06 73.490666) (xy 105.06 70.724272) (xy 105.11568 70.707382) (xy 105.225994 70.648417) + (xy 105.322685 70.569065) (xy 105.402037 70.472374) (xy 105.461002 70.36206) (xy 105.497312 70.242362) (xy 105.509572 70.11788) + (xy 105.509572 69.48288) (xy 105.497312 69.358398) (xy 105.479597 69.3) (xy 105.497312 69.241602) (xy 105.509572 69.11712) + (xy 105.5065 69.08537) (xy 105.347752 68.926622) (xy 105.36364 68.926622) + ) + ) + (filled_polygon + (pts + (xy 162.64 71.092843) (xy 162.597089 71.19644) (xy 162.565 71.35776) (xy 162.565 71.52224) (xy 162.597089 71.68356) + (xy 162.660033 71.835521) (xy 162.751413 71.972281) (xy 162.867719 72.088587) (xy 163.004479 72.179967) (xy 163.108078 72.222879) + (xy 164.240001 73.354803) (xy 164.24 78.192843) (xy 164.197089 78.29644) (xy 164.165 78.45776) (xy 164.165 78.62224) + (xy 164.197089 78.78356) (xy 164.260033 78.935521) (xy 164.351413 79.072281) (xy 164.467719 79.188587) (xy 164.604479 79.279967) + (xy 164.75644 79.342911) (xy 164.830733 79.357689) (xy 164.633422 79.555) (xy 162.203889 79.555) (xy 162.251185 79.516185) + (xy 162.330537 79.419494) (xy 162.389502 79.30918) (xy 162.425812 79.189482) (xy 162.438072 79.065) (xy 162.435 78.85075) + (xy 162.27625 78.692) (xy 161.127 78.692) (xy 161.127 78.712) (xy 161.06 78.712) (xy 161.06 78.418) + (xy 161.127 78.418) (xy 161.127 78.438) (xy 162.27625 78.438) (xy 162.435 78.27925) (xy 162.435248 78.261963) + (xy 162.565014 78.208212) (xy 162.701774 78.116832) (xy 162.81808 78.000526) (xy 162.90946 77.863766) (xy 162.972404 77.711805) + (xy 163.004493 77.550485) (xy 163.004493 77.386005) (xy 162.972404 77.224685) (xy 162.90946 77.072724) (xy 162.81808 76.935964) + (xy 162.701774 76.819658) (xy 162.565014 76.728278) (xy 162.438072 76.675697) (xy 162.438072 76.315) (xy 162.425812 76.190518) + (xy 162.389502 76.07082) (xy 162.330537 75.960506) (xy 162.251185 75.863815) (xy 162.154494 75.784463) (xy 162.04418 75.725498) + (xy 161.924482 75.689188) (xy 161.8 75.676928) (xy 161.06 75.676928) (xy 161.06 75.491077) (xy 161.063435 75.4562) + (xy 161.049727 75.317016) (xy 161.009128 75.18318) (xy 160.9432 75.059837) (xy 160.854475 74.951725) (xy 160.746363 74.863) + (xy 160.62302 74.797072) (xy 160.489184 74.756473) (xy 160.384877 74.7462) (xy 160.35 74.742765) (xy 160.315123 74.7462) + (xy 157.226914 74.7462) (xy 159.826002 72.147112) (xy 159.855 72.123314) (xy 159.90615 72.060988) (xy 159.949973 72.00759) + (xy 160.020545 71.87556) (xy 160.034365 71.830001) (xy 160.064002 71.732299) (xy 160.074999 71.620646) (xy 160.074999 71.620637) + (xy 160.078675 71.583314) (xy 160.074999 71.545991) (xy 160.074999 71.026132) (xy 160.128698 71.062012) (xy 160.517244 71.222953) + (xy 160.929721 71.305) (xy 161.350279 71.305) (xy 161.762756 71.222953) (xy 162.151302 71.062012) (xy 162.500983 70.828363) + (xy 162.640001 70.689345) + ) + ) + (filled_polygon + (pts + (xy 164.915003 56.707757) (xy 164.915003 56.872237) (xy 164.947092 57.033557) (xy 165.010036 57.185518) (xy 165.101416 57.322278) + (xy 165.217722 57.438584) (xy 165.354482 57.529964) (xy 165.458081 57.572876) (xy 167.857806 59.972602) (xy 167.881605 60.001601) + (xy 167.99733 60.096574) (xy 168.129359 60.167146) (xy 168.27262 60.210603) (xy 168.384273 60.2216) (xy 168.384282 60.2216) + (xy 168.421605 60.225276) (xy 168.458928 60.2216) (xy 169.933613 60.2216) (xy 170.752013 61.04) (xy 170.69276 61.04) + (xy 170.588731 61.060693) (xy 170.564502 60.98082) (xy 170.505537 60.870506) (xy 170.426185 60.773815) (xy 170.329494 60.694463) + (xy 170.21918 60.635498) (xy 170.099482 60.599188) (xy 169.975 60.586928) (xy 169.025 60.586928) (xy 168.900518 60.599188) + (xy 168.78082 60.635498) (xy 168.670506 60.694463) (xy 168.573815 60.773815) (xy 168.494463 60.870506) (xy 168.435498 60.98082) + (xy 168.399188 61.100518) (xy 168.386928 61.225) (xy 168.386928 62.525) (xy 168.399188 62.649482) (xy 168.435498 62.76918) + (xy 168.494463 62.879494) (xy 168.573815 62.976185) (xy 168.670506 63.055537) (xy 168.78082 63.114502) (xy 168.900518 63.150812) + (xy 169.025 63.163072) (xy 169.975 63.163072) (xy 170.099482 63.150812) (xy 170.21918 63.114502) (xy 170.329494 63.055537) + (xy 170.426185 62.976185) (xy 170.505537 62.879494) (xy 170.564502 62.76918) (xy 170.588731 62.689307) (xy 170.69276 62.71) + (xy 170.85724 62.71) (xy 171.01856 62.677911) (xy 171.122157 62.635) (xy 171.410199 62.635) (xy 173.411199 64.636001) + (xy 173.434998 64.665) (xy 173.463996 64.688798) (xy 173.550722 64.759973) (xy 173.656502 64.816514) (xy 173.682752 64.830545) + (xy 173.826013 64.874002) (xy 173.937666 64.884999) (xy 173.937675 64.884999) (xy 173.974998 64.888675) (xy 174.012321 64.884999) + (xy 174.195386 64.884999) (xy 174.197089 64.89356) (xy 174.240001 64.997159) (xy 174.240001 65.539894) (xy 174.046632 65.346525) + (xy 173.803411 65.18401) (xy 173.533158 65.072068) (xy 173.24626 65.015) (xy 173.076697 65.015) (xy 172.982327 64.975911) + (xy 172.676109 64.915) (xy 172.363891 64.915) (xy 172.057673 64.975911) (xy 171.769221 65.095391) (xy 171.509621 65.26885) + (xy 171.28885 65.489621) (xy 171.115391 65.749221) (xy 171.083084 65.827216) (xy 171.019781 65.763913) (xy 170.883021 65.672533) + (xy 170.779423 65.629622) (xy 170.613072 65.46327) (xy 170.613072 64.775) (xy 170.600812 64.650518) (xy 170.564502 64.53082) + (xy 170.505537 64.420506) (xy 170.426185 64.323815) (xy 170.329494 64.244463) (xy 170.21918 64.185498) (xy 170.099482 64.149188) + (xy 169.975 64.136928) (xy 169.025 64.136928) (xy 168.900518 64.149188) (xy 168.78082 64.185498) (xy 168.670506 64.244463) + (xy 168.573815 64.323815) (xy 168.494463 64.420506) (xy 168.435498 64.53082) (xy 168.399188 64.650518) (xy 168.386928 64.775) + (xy 168.386928 66.075) (xy 168.399188 66.199482) (xy 168.435498 66.31918) (xy 168.494463 66.429494) (xy 168.573815 66.526185) + (xy 168.670506 66.605537) (xy 168.78082 66.664502) (xy 168.900518 66.700812) (xy 169.025 66.713072) (xy 169.708204 66.713072) + (xy 169.747533 66.808021) (xy 169.838913 66.944781) (xy 169.840001 66.945869) (xy 169.840001 67.441928) (xy 169.45 67.441928) + (xy 169.325518 67.454188) (xy 169.20582 67.490498) (xy 169.095506 67.549463) (xy 168.998815 67.628815) (xy 168.919463 67.725506) + (xy 168.860498 67.83582) (xy 168.824188 67.955518) (xy 168.811928 68.08) (xy 168.811928 70.08) (xy 168.824188 70.204482) + (xy 168.860498 70.32418) (xy 168.919463 70.434494) (xy 168.998815 70.531185) (xy 169.095506 70.610537) (xy 169.0962 70.610908) + (xy 169.065 70.76776) (xy 169.065 70.93224) (xy 169.097089 71.09356) (xy 169.160033 71.245521) (xy 169.251413 71.382281) + (xy 169.367719 71.498587) (xy 169.504479 71.589967) (xy 169.65644 71.652911) (xy 169.81776 71.685) (xy 169.98224 71.685) + (xy 170.14356 71.652911) (xy 170.295521 71.589967) (xy 170.432281 71.498587) (xy 170.548587 71.382281) (xy 170.639967 71.245521) + (xy 170.702911 71.09356) (xy 170.735 70.93224) (xy 170.735 70.76776) (xy 170.725116 70.718072) (xy 171.75 70.718072) + (xy 171.874482 70.705812) (xy 171.99418 70.669502) (xy 172.104494 70.610537) (xy 172.201185 70.531185) (xy 172.228525 70.497872) + (xy 172.429017 70.698364) (xy 172.778698 70.932013) (xy 172.994302 71.021319) (xy 172.925 71.369721) (xy 172.925 71.790279) + (xy 173.007047 72.202756) (xy 173.167988 72.591302) (xy 173.401637 72.940983) (xy 173.699017 73.238363) (xy 174.048698 73.472012) + (xy 174.437244 73.632953) (xy 174.849721 73.715) (xy 175.270279 73.715) (xy 175.682756 73.632953) (xy 176.071302 73.472012) + (xy 176.420983 73.238363) (xy 176.718363 72.940983) (xy 176.952012 72.591302) (xy 177.112953 72.202756) (xy 177.195 71.790279) + (xy 177.195 71.369721) (xy 177.112953 70.957244) (xy 176.952012 70.568698) (xy 176.718363 70.219017) (xy 176.420983 69.921637) + (xy 176.071302 69.687988) (xy 175.855698 69.598682) (xy 175.897704 69.387507) (xy 177.555 71.044804) (xy 177.554999 75.527676) + (xy 177.551323 75.564999) (xy 177.554999 75.602321) (xy 177.554999 75.602331) (xy 177.565996 75.713984) (xy 177.591781 75.798986) + (xy 177.609453 75.857245) (xy 177.680025 75.989275) (xy 177.69865 76.011969) (xy 177.774998 76.105) (xy 177.804002 76.128803) + (xy 178.915198 77.24) (xy 175.884877 77.24) (xy 175.85 77.236565) (xy 175.815123 77.24) (xy 175.710816 77.250273) + (xy 175.57698 77.290872) (xy 175.453637 77.3568) (xy 175.345525 77.445525) (xy 175.2568 77.553637) (xy 175.190872 77.67698) + (xy 175.150273 77.810816) (xy 175.136565 77.95) (xy 175.140001 77.984887) (xy 175.140001 78.086928) (xy 174.4 78.086928) + (xy 174.275518 78.099188) (xy 174.15582 78.135498) (xy 174.045506 78.194463) (xy 173.948815 78.273815) (xy 173.894499 78.34) + (xy 172.741579 78.34) (xy 171.921534 77.519956) (xy 171.893817 77.486183) (xy 171.759059 77.375589) (xy 171.605313 77.293411) + (xy 171.43849 77.242805) (xy 171.308477 77.23) (xy 171.308469 77.23) (xy 171.265 77.225719) (xy 171.221531 77.23) + (xy 167.368469 77.23) (xy 167.325 77.225719) (xy 167.281531 77.23) (xy 167.281523 77.23) (xy 167.15151 77.242805) + (xy 166.984686 77.293411) (xy 166.830941 77.375589) (xy 166.729953 77.458468) (xy 166.729951 77.45847) (xy 166.696183 77.486183) + (xy 166.66847 77.519951) (xy 165.817689 78.370732) (xy 165.802911 78.29644) (xy 165.76 78.192843) (xy 165.76 73.077325) + (xy 165.763676 73.04) (xy 165.76 73.002675) (xy 165.76 73.002667) (xy 165.749003 72.891014) (xy 165.705546 72.747753) + (xy 165.634974 72.615724) (xy 165.540001 72.499999) (xy 165.511003 72.476201) (xy 164.182879 71.148078) (xy 164.16 71.092843) + (xy 164.16 70.848072) (xy 165.45 70.848072) (xy 165.574482 70.835812) (xy 165.69418 70.799502) (xy 165.804494 70.740537) + (xy 165.901185 70.661185) (xy 165.980537 70.564494) (xy 166.039502 70.45418) (xy 166.075812 70.334482) (xy 166.088072 70.21) + (xy 166.088072 68.21) (xy 166.075812 68.085518) (xy 166.039502 67.96582) (xy 165.980537 67.855506) (xy 165.901185 67.758815) + (xy 165.804494 67.679463) (xy 165.69418 67.620498) (xy 165.574482 67.584188) (xy 165.45 67.571928) (xy 164.330748 67.571928) + (xy 164.462953 67.252756) (xy 164.545 66.840279) (xy 164.545 66.419721) (xy 164.462953 66.007244) (xy 164.302012 65.618698) + (xy 164.264985 65.563283) (xy 164.430779 65.494609) (xy 164.690379 65.32115) (xy 164.91115 65.100379) (xy 165.084609 64.840779) + (xy 165.204089 64.552327) (xy 165.265 64.246109) (xy 165.265 63.933891) (xy 165.204089 63.627673) (xy 165.084609 63.339221) + (xy 164.91115 63.079621) (xy 164.690379 62.85885) (xy 164.430779 62.685391) (xy 164.142327 62.565911) (xy 163.836109 62.505) + (xy 163.523891 62.505) (xy 163.217673 62.565911) (xy 163.123303 62.605) (xy 162.95374 62.605) (xy 162.666842 62.662068) + (xy 162.396589 62.77401) (xy 162.293999 62.842558) (xy 162.293999 62.470802) (xy 164.061003 60.703799) (xy 164.090001 60.680001) + (xy 164.129778 60.631533) (xy 164.184974 60.564277) (xy 164.255546 60.432247) (xy 164.263204 60.407) (xy 164.299003 60.288986) + (xy 164.31 60.177333) (xy 164.31 60.177323) (xy 164.313676 60.14) (xy 164.31 60.102677) (xy 164.31 59.177322) + (xy 164.313676 59.139999) (xy 164.31 59.102676) (xy 164.31 59.102667) (xy 164.299003 58.991014) (xy 164.255546 58.847753) + (xy 164.184974 58.715724) (xy 164.090001 58.599999) (xy 164.061003 58.576201) (xy 163.713803 58.229002) (xy 163.690001 58.199999) + (xy 163.574276 58.105026) (xy 163.442247 58.034454) (xy 163.298986 57.990997) (xy 163.187333 57.98) (xy 163.187322 57.98) + (xy 163.15 57.976324) (xy 163.112678 57.98) (xy 162.647157 57.98) (xy 162.591923 57.957122) (xy 162.438072 57.80327) + (xy 162.438072 57.215) (xy 162.425812 57.090518) (xy 162.389502 56.97082) (xy 162.330537 56.860506) (xy 162.251185 56.763815) + (xy 162.234351 56.75) (xy 164.512678 56.75) (xy 164.55 56.753676) (xy 164.587322 56.75) (xy 164.587333 56.75) + (xy 164.698986 56.739003) (xy 164.842247 56.695546) (xy 164.926377 56.650577) + ) + ) + (filled_polygon + (pts + (xy 131.740001 67.414803) (xy 131.740001 67.541928) (xy 131.35 67.541928) (xy 131.225518 67.554188) (xy 131.10582 67.590498) + (xy 130.995506 67.649463) (xy 130.898815 67.728815) (xy 130.819463 67.825506) (xy 130.760498 67.93582) (xy 130.724188 68.055518) + (xy 130.711928 68.18) (xy 130.711928 70.18) (xy 130.724188 70.304482) (xy 130.760498 70.42418) (xy 130.819463 70.534494) + (xy 130.898815 70.631185) (xy 130.987616 70.704062) (xy 130.965 70.81776) (xy 130.965 70.98224) (xy 130.997089 71.14356) + (xy 131.060033 71.295521) (xy 131.151413 71.432281) (xy 131.267719 71.548587) (xy 131.404479 71.639967) (xy 131.55644 71.702911) + (xy 131.71776 71.735) (xy 131.88224 71.735) (xy 132.04356 71.702911) (xy 132.195521 71.639967) (xy 132.332281 71.548587) + (xy 132.448587 71.432281) (xy 132.539967 71.295521) (xy 132.602911 71.14356) (xy 132.635 70.98224) (xy 132.635 70.818072) + (xy 133.65 70.818072) (xy 133.774482 70.805812) (xy 133.89418 70.769502) (xy 134.004494 70.710537) (xy 134.101185 70.631185) + (xy 134.128525 70.597872) (xy 134.329017 70.798364) (xy 134.678698 71.032013) (xy 134.894302 71.121319) (xy 134.825 71.469721) + (xy 134.825 71.890279) (xy 134.907047 72.302756) (xy 135.067988 72.691302) (xy 135.301637 73.040983) (xy 135.599017 73.338363) + (xy 135.948698 73.572012) (xy 136.337244 73.732953) (xy 136.749721 73.815) (xy 137.170279 73.815) (xy 137.582756 73.732953) + (xy 137.971302 73.572012) (xy 138.320983 73.338363) (xy 138.618363 73.040983) (xy 138.852012 72.691302) (xy 139.012953 72.302756) + (xy 139.095 71.890279) (xy 139.095 71.469721) (xy 139.012953 71.057244) (xy 138.852012 70.668698) (xy 138.618363 70.319017) + (xy 138.320983 70.021637) (xy 137.971302 69.787988) (xy 137.755698 69.698682) (xy 137.814295 69.404098) (xy 139.454999 71.044803) + (xy 139.455 74.927667) (xy 139.451323 74.964999) (xy 139.455 75.002332) (xy 139.465997 75.113985) (xy 139.473889 75.140001) + (xy 139.509453 75.257245) (xy 139.580025 75.389275) (xy 139.647879 75.471954) (xy 139.674999 75.505) (xy 139.703997 75.528798) + (xy 141.14 76.964802) (xy 141.14 77.24) (xy 137.784877 77.24) (xy 137.75 77.236565) (xy 137.715123 77.24) + (xy 137.610816 77.250273) (xy 137.47698 77.290872) (xy 137.353637 77.3568) (xy 137.245525 77.445525) (xy 137.1568 77.553637) + (xy 137.090872 77.67698) (xy 137.050273 77.810816) (xy 137.036565 77.95) (xy 137.040001 77.984887) (xy 137.040001 78.086928) + (xy 136.3 78.086928) (xy 136.175518 78.099188) (xy 136.05582 78.135498) (xy 135.945506 78.194463) (xy 135.890019 78.24) + (xy 133.118476 78.24) (xy 133.075 78.235718) (xy 133.031523 78.24) (xy 132.928705 78.250127) (xy 130.335 75.656422) + (xy 130.335 69.105471) (xy 130.339281 69.062002) (xy 130.335 69.018533) (xy 130.335 69.018525) (xy 130.322195 68.888512) + (xy 130.308937 68.844808) (xy 130.271589 68.721688) (xy 130.189411 68.567943) (xy 130.106532 68.466955) (xy 130.10653 68.466953) + (xy 130.078817 68.433185) (xy 130.045049 68.405472) (xy 129.734999 68.095423) (xy 129.734999 66.863072) (xy 130.275 66.863072) + (xy 130.399482 66.850812) (xy 130.51918 66.814502) (xy 130.629494 66.755537) (xy 130.726185 66.676185) (xy 130.805537 66.579494) + (xy 130.840076 66.514877) + ) + ) + (filled_polygon + (pts + (xy 216.979017 59.138363) (xy 217.328698 59.372012) (xy 217.717244 59.532953) (xy 218.129721 59.615) (xy 218.550279 59.615) + (xy 218.962756 59.532953) (xy 219.351302 59.372012) (xy 219.700983 59.138363) (xy 219.74 59.099346) (xy 219.74 59.402843) + (xy 219.697089 59.50644) (xy 219.665 59.66776) (xy 219.665 59.83224) (xy 219.697089 59.99356) (xy 219.760033 60.145521) + (xy 219.851413 60.282281) (xy 219.967719 60.398587) (xy 220.104479 60.489967) (xy 220.208078 60.532879) (xy 221.295002 61.619804) + (xy 221.295001 69.797729) (xy 221.242327 69.775911) (xy 220.936109 69.715) (xy 220.623891 69.715) (xy 220.317673 69.775911) + (xy 220.223303 69.815) (xy 220.05374 69.815) (xy 219.766842 69.872068) (xy 219.496589 69.98401) (xy 219.253368 70.146525) + (xy 219.046525 70.353368) (xy 218.88401 70.596589) (xy 218.772068 70.866842) (xy 218.715 71.15374) (xy 218.715 71.44626) + (xy 218.772068 71.733158) (xy 218.807988 71.819876) (xy 218.498698 71.947988) (xy 218.276252 72.096622) (xy 218.281817 72.083186) + (xy 218.385 71.564449) (xy 218.385 71.035551) (xy 218.281817 70.516814) (xy 218.079417 70.028175) (xy 217.785576 69.588412) + (xy 217.411588 69.214424) (xy 216.971825 68.920583) (xy 216.5262 68.736) (xy 217.415123 68.736) (xy 217.45 68.739435) + (xy 217.484877 68.736) (xy 217.589184 68.725727) (xy 217.72302 68.685128) (xy 217.846363 68.6192) (xy 217.954475 68.530475) + (xy 218.0432 68.422363) (xy 218.109128 68.29902) (xy 218.149727 68.165184) (xy 218.163435 68.026) (xy 218.16 67.991123) + (xy 218.16 67.81) (xy 218.227002 67.81) (xy 218.227002 67.651252) (xy 218.38575 67.81) (xy 218.9 67.813072) + (xy 219.024482 67.800812) (xy 219.14418 67.764502) (xy 219.254494 67.705537) (xy 219.351185 67.626185) (xy 219.430537 67.529494) + (xy 219.489502 67.41918) (xy 219.525812 67.299482) (xy 219.538072 67.175) (xy 219.535 66.96075) (xy 219.376252 66.802002) + (xy 219.535 66.802002) (xy 219.535 66.6845) (xy 219.60174 66.6845) (xy 219.76306 66.652411) (xy 219.915021 66.589467) + (xy 220.051781 66.498087) (xy 220.168087 66.381781) (xy 220.259467 66.245021) (xy 220.322411 66.09306) (xy 220.3545 65.93174) + (xy 220.3545 65.76726) (xy 220.322411 65.60594) (xy 220.2795 65.502343) (xy 220.2795 65.251823) (xy 220.283176 65.2145) + (xy 220.2795 65.177177) (xy 220.2795 65.177167) (xy 220.268503 65.065514) (xy 220.225046 64.922253) (xy 220.154474 64.790224) + (xy 220.059501 64.674499) (xy 220.030498 64.650697) (xy 219.793804 64.414003) (xy 219.770001 64.384999) (xy 219.654276 64.290026) + (xy 219.522247 64.219454) (xy 219.499091 64.21243) (xy 219.489502 64.18082) (xy 219.430537 64.070506) (xy 219.351185 63.973815) + (xy 219.254494 63.894463) (xy 219.14418 63.835498) (xy 219.024482 63.799188) (xy 218.9 63.786928) (xy 218.86 63.786928) + (xy 218.86 63.337322) (xy 218.863676 63.299999) (xy 218.86 63.262676) (xy 218.86 63.262667) (xy 218.849003 63.151014) + (xy 218.805546 63.007753) (xy 218.734974 62.875724) (xy 218.640001 62.759999) (xy 218.611004 62.736202) (xy 216.8488 60.973999) + (xy 216.8488 59.008146) + ) + ) + (filled_polygon + (pts + (xy 114.04347 62.095049) (xy 114.071183 62.128817) (xy 114.104951 62.15653) (xy 114.104953 62.156532) (xy 114.126222 62.173987) + (xy 114.205941 62.239411) (xy 114.359687 62.321589) (xy 114.52651 62.372195) (xy 114.656523 62.385) (xy 114.656533 62.385) + (xy 114.699999 62.389281) (xy 114.743466 62.385) (xy 115.433422 62.385) (xy 116.183777 63.135355) (xy 116.101413 63.217719) + (xy 116.010033 63.354479) (xy 115.947089 63.50644) (xy 115.915 63.66776) (xy 115.915 63.83224) (xy 115.947089 63.99356) + (xy 115.99 64.097157) (xy 115.99 64.100699) (xy 115.688998 64.401701) (xy 115.66 64.425499) (xy 115.565026 64.541224) + (xy 115.494454 64.673253) (xy 115.450997 64.816514) (xy 115.44 64.928167) (xy 115.44 64.928178) (xy 115.436324 64.9655) + (xy 115.44 65.002822) (xy 115.44 65.102843) (xy 115.397089 65.20644) (xy 115.365 65.36776) (xy 115.365 65.53224) + (xy 115.397089 65.69356) (xy 115.460033 65.845521) (xy 115.551413 65.982281) (xy 115.667719 66.098587) (xy 115.804479 66.189967) + (xy 115.95644 66.252911) (xy 116.11776 66.285) (xy 116.28224 66.285) (xy 116.44356 66.252911) (xy 116.595521 66.189967) + (xy 116.732281 66.098587) (xy 116.848587 65.982281) (xy 116.939967 65.845521) (xy 117.002911 65.69356) (xy 117.0312 65.551342) + (xy 117.05582 65.564502) (xy 117.175518 65.600812) (xy 117.3 65.613072) (xy 118.04 65.613072) (xy 118.04 65.815123) + (xy 118.036565 65.85) (xy 118.050273 65.989184) (xy 118.090872 66.12302) (xy 118.1568 66.246363) (xy 118.245525 66.354475) + (xy 118.259365 66.365833) (xy 117.488998 67.136201) (xy 117.46 67.159999) (xy 117.436202 67.188997) (xy 117.436201 67.188998) + (xy 117.365026 67.275724) (xy 117.294454 67.407754) (xy 117.270719 67.486002) (xy 117.250998 67.551014) (xy 117.240001 67.662667) + (xy 117.236324 67.7) (xy 117.240001 67.737332) (xy 117.240001 68.282863) (xy 117.153475 68.153368) (xy 116.946632 67.946525) + (xy 116.703411 67.78401) (xy 116.433158 67.672068) (xy 116.14626 67.615) (xy 115.976697 67.615) (xy 115.882327 67.575911) + (xy 115.576109 67.515) (xy 115.263891 67.515) (xy 114.957673 67.575911) (xy 114.669221 67.695391) (xy 114.409621 67.86885) + (xy 114.18885 68.089621) (xy 114.015391 68.349221) (xy 113.895911 68.637673) (xy 113.835 68.943891) (xy 113.835 69.256109) + (xy 113.895911 69.562327) (xy 114.015391 69.850779) (xy 114.143113 70.041928) (xy 112.35 70.041928) (xy 112.225518 70.054188) + (xy 112.10582 70.090498) (xy 111.995506 70.149463) (xy 111.900487 70.227443) (xy 111.658049 69.985005) (xy 111.732235 69.985005) + (xy 111.893555 69.952916) (xy 112.045516 69.889972) (xy 112.182276 69.798592) (xy 112.298582 69.682286) (xy 112.389962 69.545526) + (xy 112.452906 69.393565) (xy 112.484995 69.232245) (xy 112.484995 69.067765) (xy 112.452906 68.906445) (xy 112.409995 68.802848) + (xy 112.409995 64.864806) (xy 112.610998 64.663803) (xy 112.640001 64.640001) (xy 112.734974 64.524276) (xy 112.805546 64.392247) + (xy 112.849003 64.248986) (xy 112.86 64.137333) (xy 112.86 64.137324) (xy 112.863676 64.100001) (xy 112.86 64.062678) + (xy 112.86 60.911578) + ) + ) + (filled_polygon + (pts + (xy 104.427 68.67262) (xy 104.447 68.67262) (xy 104.447 68.844808) (xy 104.153 68.844808) (xy 104.153 68.67262) + (xy 104.173 68.67262) (xy 104.173 68.65262) (xy 104.427 68.65262) + ) + ) + (filled_polygon + (pts + (xy 141.175 49.829721) (xy 141.175 50.250279) (xy 141.244302 50.598682) (xy 141.028698 50.687988) (xy 140.679017 50.921637) + (xy 140.381637 51.219017) (xy 140.147988 51.568698) (xy 139.987047 51.957244) (xy 139.905 52.369721) (xy 139.905 52.790279) + (xy 139.987047 53.202756) (xy 140.147988 53.591302) (xy 140.381637 53.940983) (xy 140.679017 54.238363) (xy 141.028698 54.472012) + (xy 141.417244 54.632953) (xy 141.829721 54.715) (xy 142.250279 54.715) (xy 142.662756 54.632953) (xy 143.051302 54.472012) + (xy 143.400983 54.238363) (xy 143.540001 54.099345) (xy 143.54 54.552843) (xy 143.497089 54.65644) (xy 143.465 54.81776) + (xy 143.465 54.98224) (xy 143.497089 55.14356) (xy 143.560033 55.295521) (xy 143.651413 55.432281) (xy 143.767719 55.548587) + (xy 143.904479 55.639967) (xy 144.008078 55.682879) (xy 145.095001 56.769803) (xy 145.095002 65.097729) (xy 145.042327 65.075911) + (xy 144.736109 65.015) (xy 144.423891 65.015) (xy 144.117673 65.075911) (xy 144.023303 65.115) (xy 143.85374 65.115) + (xy 143.566842 65.172068) (xy 143.296589 65.28401) (xy 143.053368 65.446525) (xy 142.846525 65.653368) (xy 142.68401 65.896589) + (xy 142.572068 66.166842) (xy 142.515 66.45374) (xy 142.515 66.74626) (xy 142.572068 67.033158) (xy 142.607988 67.119876) + (xy 142.298698 67.247988) (xy 142.076252 67.396622) (xy 142.081817 67.383186) (xy 142.185 66.864449) (xy 142.185 66.335551) + (xy 142.081817 65.816814) (xy 141.879417 65.328175) (xy 141.585576 64.888412) (xy 141.211588 64.514424) (xy 140.771825 64.220583) + (xy 140.625564 64.16) (xy 141.215123 64.16) (xy 141.25 64.163435) (xy 141.284877 64.16) (xy 141.312485 64.157281) + (xy 141.389184 64.149727) (xy 141.52302 64.109128) (xy 141.646363 64.0432) (xy 141.754475 63.954475) (xy 141.8432 63.846363) + (xy 141.909128 63.72302) (xy 141.949727 63.589184) (xy 141.96 63.484877) (xy 141.96 63.484876) (xy 141.963435 63.45) + (xy 141.96 63.415123) (xy 141.96 63.11) (xy 142.027002 63.11) (xy 142.027002 62.951252) (xy 142.18575 63.11) + (xy 142.7 63.113072) (xy 142.824482 63.100812) (xy 142.94418 63.064502) (xy 143.054494 63.005537) (xy 143.151185 62.926185) + (xy 143.230537 62.829494) (xy 143.289502 62.71918) (xy 143.325812 62.599482) (xy 143.338072 62.475) (xy 143.335 62.26075) + (xy 143.17625 62.102) (xy 142.027 62.102) (xy 142.027 62.122) (xy 141.96 62.122) (xy 141.96 61.828) + (xy 142.027 61.828) (xy 142.027 61.848) (xy 143.17625 61.848) (xy 143.243985 61.780265) (xy 143.26776 61.784994) + (xy 143.43224 61.784994) (xy 143.59356 61.752905) (xy 143.745521 61.689961) (xy 143.882281 61.598581) (xy 143.998587 61.482275) + (xy 144.089967 61.345515) (xy 144.152911 61.193554) (xy 144.185 61.032234) (xy 144.185 60.867754) (xy 144.152911 60.706434) + (xy 144.11 60.602837) (xy 144.11 60.519822) (xy 144.113676 60.482499) (xy 144.11 60.445176) (xy 144.11 60.445167) + (xy 144.099003 60.333514) (xy 144.055546 60.190253) (xy 143.984974 60.058224) (xy 143.890001 59.942499) (xy 143.860998 59.918697) + (xy 143.556304 59.614003) (xy 143.532501 59.584999) (xy 143.416776 59.490026) (xy 143.284747 59.419454) (xy 143.251273 59.4093) + (xy 143.230537 59.370506) (xy 143.151185 59.273815) (xy 143.054494 59.194463) (xy 142.94418 59.135498) (xy 142.824482 59.099188) + (xy 142.7 59.086928) (xy 142.66 59.086928) (xy 142.66 58.237323) (xy 142.663676 58.2) (xy 142.66 58.162677) + (xy 142.66 58.162667) (xy 142.649003 58.051014) (xy 142.605546 57.907753) (xy 142.534974 57.775724) (xy 142.440001 57.659999) + (xy 142.411004 57.636202) (xy 139.545001 54.7702) (xy 139.545001 50.237326) (xy 139.548677 50.200003) (xy 139.547199 50.185) + (xy 139.764449 50.185) (xy 140.283186 50.081817) (xy 140.771825 49.879417) (xy 141.211588 49.585576) (xy 141.226537 49.570627) + ) + ) + (filled_polygon + (pts + (xy 199.227 66.548) (xy 199.247 66.548) (xy 199.247 66.802) (xy 199.227 66.802) (xy 199.227 66.822) + (xy 199.16 66.822) (xy 199.16 66.528) (xy 199.227 66.528) + ) + ) + (filled_polygon + (pts + (xy 218.227 66.548) (xy 218.247 66.548) (xy 218.247 66.802) (xy 218.227 66.802) (xy 218.227 66.822) + (xy 218.16 66.822) (xy 218.16 66.528) (xy 218.227 66.528) + ) + ) + (filled_polygon + (pts + (xy 186.886928 48.436731) (xy 186.886928 49.125) (xy 186.899188 49.249482) (xy 186.935498 49.36918) (xy 186.994463 49.479494) + (xy 187.073815 49.576185) (xy 187.167863 49.653368) (xy 187.165 49.66776) (xy 187.165 49.83224) (xy 187.197089 49.99356) + (xy 187.260033 50.145521) (xy 187.329844 50.25) (xy 187.260033 50.354479) (xy 187.197089 50.50644) (xy 187.165 50.66776) + (xy 187.165 50.83224) (xy 187.167863 50.846632) (xy 187.073815 50.923815) (xy 186.994463 51.020506) (xy 186.935498 51.13082) + (xy 186.899188 51.250518) (xy 186.886928 51.375) (xy 186.886928 52.675) (xy 186.899188 52.799482) (xy 186.935498 52.91918) + (xy 186.994463 53.029494) (xy 187.073815 53.126185) (xy 187.170506 53.205537) (xy 187.28082 53.264502) (xy 187.400518 53.300812) + (xy 187.525 53.313072) (xy 188.475 53.313072) (xy 188.599482 53.300812) (xy 188.71918 53.264502) (xy 188.829494 53.205537) + (xy 188.926185 53.126185) (xy 188.940001 53.109351) (xy 188.940001 53.341928) (xy 188.55 53.341928) (xy 188.425518 53.354188) + (xy 188.30582 53.390498) (xy 188.195506 53.449463) (xy 188.098815 53.528815) (xy 188.019463 53.625506) (xy 187.960498 53.73582) + (xy 187.924188 53.855518) (xy 187.911928 53.98) (xy 187.911928 55.98) (xy 187.924188 56.104482) (xy 187.960498 56.22418) + (xy 188.019463 56.334494) (xy 188.098815 56.431185) (xy 188.195506 56.510537) (xy 188.30582 56.569502) (xy 188.37143 56.589405) + (xy 188.457754 56.635546) (xy 188.601015 56.679002) (xy 188.659381 56.684751) (xy 188.626413 56.717719) (xy 188.535033 56.854479) + (xy 188.472089 57.00644) (xy 188.44 57.16776) (xy 188.44 57.33224) (xy 188.472089 57.49356) (xy 188.515001 57.597158) + (xy 188.515 58.275179) (xy 188.511324 58.312502) (xy 188.515 58.349824) (xy 188.515 58.349834) (xy 188.525997 58.461487) + (xy 188.565288 58.591014) (xy 188.569454 58.604748) (xy 188.640026 58.736778) (xy 188.670562 58.773986) (xy 188.734999 58.852503) + (xy 188.764002 58.876305) (xy 189.439998 59.552302) (xy 189.439999 62.819167) (xy 189.419052 62.815) (xy 189.254572 62.815) + (xy 189.093252 62.847089) (xy 188.989655 62.89) (xy 181.173426 62.89) (xy 181.251185 62.826185) (xy 181.330537 62.729494) + (xy 181.389502 62.61918) (xy 181.425812 62.499482) (xy 181.438072 62.375) (xy 181.435 62.16075) (xy 181.276252 62.002002) + (xy 181.435 62.002002) (xy 181.435 61.928484) (xy 181.467758 61.935) (xy 181.632238 61.935) (xy 181.793558 61.902911) + (xy 181.945519 61.839967) (xy 182.082279 61.748587) (xy 182.198585 61.632281) (xy 182.239423 61.571163) (xy 182.301424 61.663954) + (xy 182.41773 61.78026) (xy 182.55449 61.87164) (xy 182.706451 61.934584) (xy 182.867771 61.966673) (xy 183.032251 61.966673) + (xy 183.193571 61.934584) (xy 183.345532 61.87164) (xy 183.482292 61.78026) (xy 183.598598 61.663954) (xy 183.689978 61.527194) + (xy 183.752922 61.375233) (xy 183.785011 61.213913) (xy 183.785011 61.049433) (xy 183.752922 60.888113) (xy 183.710011 60.784516) + (xy 183.710011 55.437333) (xy 183.713687 55.40001) (xy 183.710011 55.362688) (xy 183.710011 55.362678) (xy 183.699014 55.251025) + (xy 183.655557 55.107764) (xy 183.636975 55.073) (xy 183.584985 54.975734) (xy 183.51381 54.889008) (xy 183.490012 54.86001) + (xy 183.461014 54.836213) (xy 183.182879 54.558077) (xy 183.16 54.502843) (xy 183.16 54.258072) (xy 184.45 54.258072) + (xy 184.574482 54.245812) (xy 184.69418 54.209502) (xy 184.804494 54.150537) (xy 184.901185 54.071185) (xy 184.980537 53.974494) + (xy 185.039502 53.86418) (xy 185.075812 53.744482) (xy 185.088072 53.62) (xy 185.088072 51.62) (xy 185.075812 51.495518) + (xy 185.039502 51.37582) (xy 184.980537 51.265506) (xy 184.901185 51.168815) (xy 184.804494 51.089463) (xy 184.69418 51.030498) + (xy 184.574482 50.994188) (xy 184.45 50.981928) (xy 183.330748 50.981928) (xy 183.462953 50.662756) (xy 183.545 50.250279) + (xy 183.545 49.829721) (xy 183.462953 49.417244) (xy 183.302012 49.028698) (xy 183.264985 48.973283) (xy 183.430779 48.904609) + (xy 183.690379 48.73115) (xy 183.91115 48.510379) (xy 184.084609 48.250779) (xy 184.204089 47.962327) (xy 184.265 47.656109) + (xy 184.265 47.343891) (xy 184.204089 47.037673) (xy 184.084609 46.749221) (xy 183.91115 46.489621) (xy 183.690379 46.26885) + (xy 183.430779 46.095391) (xy 183.142327 45.975911) (xy 182.836109 45.915) (xy 182.523891 45.915) (xy 182.217673 45.975911) + (xy 182.123303 46.015) (xy 181.95374 46.015) (xy 181.666842 46.072068) (xy 181.396589 46.18401) (xy 181.153368 46.346525) + (xy 180.946525 46.553368) (xy 180.78401 46.796589) (xy 180.672068 47.066842) (xy 180.615 47.35374) (xy 180.615 47.64626) + (xy 180.672068 47.933158) (xy 180.707988 48.019876) (xy 180.398698 48.147988) (xy 180.176252 48.296622) (xy 180.181817 48.283186) + (xy 180.285 47.764449) (xy 180.285 47.235551) (xy 180.181817 46.716814) (xy 179.979417 46.228175) (xy 179.750114 45.884999) + (xy 184.335198 45.884999) + ) + ) + (filled_polygon + (pts + (xy 180.127 61.748) (xy 180.147 61.748) (xy 180.147 62.002) (xy 180.127 62.002) (xy 180.127 62.022) + (xy 180.06 62.022) (xy 180.06 61.728) (xy 180.127 61.728) + ) + ) + (filled_polygon + (pts + (xy 181.64 54.502843) (xy 181.597089 54.60644) (xy 181.565 54.76776) (xy 181.565 54.93224) (xy 181.597089 55.09356) + (xy 181.660033 55.245521) (xy 181.751413 55.382281) (xy 181.867719 55.498587) (xy 182.004479 55.589967) (xy 182.108077 55.632879) + (xy 182.190011 55.714813) (xy 182.190012 60.559146) (xy 182.082279 60.451413) (xy 181.945519 60.360033) (xy 181.793558 60.297089) + (xy 181.632238 60.265) (xy 181.481802 60.265) (xy 181.438072 60.22127) (xy 181.438072 59.625) (xy 181.425812 59.500518) + (xy 181.389502 59.38082) (xy 181.330537 59.270506) (xy 181.251185 59.173815) (xy 181.154494 59.094463) (xy 181.04418 59.035498) + (xy 180.924482 58.999188) (xy 180.8 58.986928) (xy 180.76 58.986928) (xy 180.76 58.037322) (xy 180.763676 57.999999) + (xy 180.76 57.962676) (xy 180.76 57.962667) (xy 180.749003 57.851014) (xy 180.705546 57.707753) (xy 180.634974 57.575724) + (xy 180.540001 57.459999) (xy 180.511004 57.436202) (xy 179.074999 56.000198) (xy 179.074999 54.436132) (xy 179.128698 54.472012) + (xy 179.517244 54.632953) (xy 179.929721 54.715) (xy 180.350279 54.715) (xy 180.762756 54.632953) (xy 181.151302 54.472012) + (xy 181.500983 54.238363) (xy 181.640001 54.099345) + ) + ) + (filled_polygon + (pts + (xy 168.136928 44.3) (xy 168.149188 44.424482) (xy 168.185498 44.54418) (xy 168.244463 44.654494) (xy 168.323815 44.751185) + (xy 168.420506 44.830537) (xy 168.468011 44.855929) (xy 168.447089 44.90644) (xy 168.415 45.06776) (xy 168.415 45.23224) + (xy 168.447089 45.39356) (xy 168.510033 45.545521) (xy 168.579844 45.65) (xy 168.510033 45.754479) (xy 168.447089 45.90644) + (xy 168.425095 46.01701) (xy 168.420506 46.019463) (xy 168.323815 46.098815) (xy 168.244463 46.195506) (xy 168.185498 46.30582) + (xy 168.149188 46.425518) (xy 168.136928 46.55) (xy 168.136928 47.85) (xy 168.149188 47.974482) (xy 168.185498 48.09418) + (xy 168.244463 48.204494) (xy 168.323815 48.301185) (xy 168.420506 48.380537) (xy 168.490001 48.417683) (xy 168.490001 48.692668) + (xy 168.486324 48.73) (xy 168.490001 48.767333) (xy 168.500998 48.878986) (xy 168.510281 48.909587) (xy 168.544454 49.022246) + (xy 168.615026 49.154276) (xy 168.672376 49.224156) (xy 168.71 49.270001) (xy 168.738998 49.293799) (xy 168.811928 49.366729) + (xy 168.811928 51.08) (xy 168.824188 51.204482) (xy 168.860498 51.32418) (xy 168.919463 51.434494) (xy 168.998815 51.531185) + (xy 169.095506 51.610537) (xy 169.0962 51.610908) (xy 169.065 51.76776) (xy 169.065 51.93224) (xy 169.097089 52.09356) + (xy 169.160033 52.245521) (xy 169.251413 52.382281) (xy 169.367719 52.498587) (xy 169.504479 52.589967) (xy 169.65644 52.652911) + (xy 169.81776 52.685) (xy 169.98224 52.685) (xy 170.14356 52.652911) (xy 170.295521 52.589967) (xy 170.432281 52.498587) + (xy 170.548587 52.382281) (xy 170.639967 52.245521) (xy 170.702911 52.09356) (xy 170.735 51.93224) (xy 170.735 51.76776) + (xy 170.725116 51.718072) (xy 171.75 51.718072) (xy 171.874482 51.705812) (xy 171.99418 51.669502) (xy 172.104494 51.610537) + (xy 172.201185 51.531185) (xy 172.228525 51.497872) (xy 172.429017 51.698364) (xy 172.778698 51.932013) (xy 172.994302 52.021319) + (xy 172.925 52.369721) (xy 172.925 52.790279) (xy 173.007047 53.202756) (xy 173.167988 53.591302) (xy 173.401637 53.940983) + (xy 173.699017 54.238363) (xy 174.048698 54.472012) (xy 174.437244 54.632953) (xy 174.849721 54.715) (xy 175.270279 54.715) + (xy 175.682756 54.632953) (xy 176.071302 54.472012) (xy 176.420983 54.238363) (xy 176.718363 53.940983) (xy 176.952012 53.591302) + (xy 177.112953 53.202756) (xy 177.195 52.790279) (xy 177.195 52.369721) (xy 177.112953 51.957244) (xy 176.957043 51.580845) + (xy 177.554999 52.178801) (xy 177.555 56.277667) (xy 177.551323 56.314999) (xy 177.555 56.352332) (xy 177.565997 56.463985) + (xy 177.574085 56.490647) (xy 177.609453 56.607245) (xy 177.680025 56.739275) (xy 177.741724 56.814454) (xy 177.774999 56.855) + (xy 177.803997 56.878798) (xy 178.963598 58.0384) (xy 175.884877 58.0384) (xy 175.85 58.034965) (xy 175.815123 58.0384) + (xy 175.710816 58.048673) (xy 175.57698 58.089272) (xy 175.453637 58.1552) (xy 175.345525 58.243925) (xy 175.2568 58.352037) + (xy 175.190872 58.47538) (xy 175.150273 58.609216) (xy 175.136565 58.7484) (xy 175.140001 58.783287) (xy 175.140001 58.986928) + (xy 174.4 58.986928) (xy 174.275518 58.999188) (xy 174.15582 59.035498) (xy 174.045506 59.094463) (xy 173.948815 59.173815) + (xy 173.894499 59.24) (xy 173.418466 59.24) (xy 173.374999 59.235719) (xy 173.331533 59.24) (xy 173.331523 59.24) + (xy 173.20151 59.252805) (xy 173.034687 59.303411) (xy 172.880941 59.385589) (xy 172.746183 59.496183) (xy 172.718466 59.529956) + (xy 172.404956 59.843466) (xy 172.371183 59.871183) (xy 172.260589 60.005942) (xy 172.178411 60.159688) (xy 172.14541 60.268476) + (xy 172.141845 60.280229) (xy 170.812218 58.950603) (xy 170.788415 58.921599) (xy 170.67269 58.826626) (xy 170.540661 58.756054) + (xy 170.3974 58.712597) (xy 170.285747 58.7016) (xy 170.285736 58.7016) (xy 170.248414 58.697924) (xy 170.211092 58.7016) + (xy 168.736408 58.7016) (xy 166.532882 56.498075) (xy 166.48997 56.394476) (xy 166.39859 56.257716) (xy 166.282284 56.14141) + (xy 166.145524 56.05003) (xy 165.993563 55.987086) (xy 165.832243 55.954997) (xy 165.667763 55.954997) (xy 165.657828 55.956973) + (xy 166.286004 55.328798) (xy 166.315002 55.305) (xy 166.341882 55.272247) (xy 166.409975 55.189276) (xy 166.480547 55.057246) + (xy 166.487295 55.035) (xy 166.524004 54.913985) (xy 166.535001 54.802332) (xy 166.535001 54.802323) (xy 166.538677 54.765) + (xy 166.535001 54.727677) (xy 166.535001 51.632323) (xy 166.538677 51.595) (xy 166.535001 51.557677) (xy 166.535001 51.557668) + (xy 166.524004 51.446015) (xy 166.480547 51.302754) (xy 166.409975 51.170725) (xy 166.377226 51.13082) (xy 166.3388 51.083997) + (xy 166.338796 51.083993) (xy 166.315002 51.055) (xy 166.28601 51.031207) (xy 166.088072 50.833269) (xy 166.088072 49.12) + (xy 166.075812 48.995518) (xy 166.039502 48.87582) (xy 165.980537 48.765506) (xy 165.901185 48.668815) (xy 165.804494 48.589463) + (xy 165.69418 48.530498) (xy 165.574482 48.494188) (xy 165.45 48.481928) (xy 164.330748 48.481928) (xy 164.462953 48.162756) + (xy 164.545 47.750279) (xy 164.545 47.329721) (xy 164.462953 46.917244) (xy 164.302012 46.528698) (xy 164.264985 46.473283) + (xy 164.430779 46.404609) (xy 164.690379 46.23115) (xy 164.91115 46.010379) (xy 165.084609 45.750779) (xy 165.204089 45.462327) + (xy 165.265 45.156109) (xy 165.265 44.843891) (xy 165.204089 44.537673) (xy 165.10382 44.2956) (xy 168.136928 44.2956) + ) + ) + (filled_polygon + (pts + (xy 162.790001 59.825197) (xy 162.370536 60.244662) (xy 162.389502 60.20918) (xy 162.425812 60.089482) (xy 162.438072 59.965) + (xy 162.435 59.75075) (xy 162.276252 59.592002) (xy 162.435 59.592002) (xy 162.435 59.564505) (xy 162.54356 59.542911) + (xy 162.647157 59.5) (xy 162.79 59.5) + ) + ) + (filled_polygon + (pts + (xy 161.127 59.338) (xy 161.147 59.338) (xy 161.147 59.592) (xy 161.127 59.592) (xy 161.127 59.612) + (xy 161.06 59.612) (xy 161.06 59.318) (xy 161.127 59.318) + ) + ) + (filled_polygon + (pts + (xy 149.386928 45.465) (xy 149.399188 45.589482) (xy 149.435498 45.70918) (xy 149.494463 45.819494) (xy 149.573815 45.916185) + (xy 149.670506 45.995537) (xy 149.78082 46.054502) (xy 149.900518 46.090812) (xy 150.025 46.103072) (xy 150.030183 46.103072) + (xy 149.998815 46.128815) (xy 149.919463 46.225506) (xy 149.860498 46.33582) (xy 149.824188 46.455518) (xy 149.811928 46.58) + (xy 149.811928 48.384982) (xy 149.800998 48.421014) (xy 149.793218 48.500001) (xy 149.786324 48.57) (xy 149.790001 48.607332) + (xy 149.79 49.292842) (xy 149.747089 49.39644) (xy 149.715 49.55776) (xy 149.715 49.72224) (xy 149.747089 49.88356) + (xy 149.79 49.987157) (xy 149.790001 51.568116) (xy 149.717719 51.616413) (xy 149.601413 51.732719) (xy 149.510033 51.869479) + (xy 149.447089 52.02144) (xy 149.415 52.18276) (xy 149.415 52.34724) (xy 149.447089 52.50856) (xy 149.510033 52.660521) + (xy 149.601413 52.797281) (xy 149.717719 52.913587) (xy 149.854479 53.004967) (xy 149.958078 53.047879) (xy 152.140001 55.229803) + (xy 152.14 55.675199) (xy 151.739003 56.076196) (xy 151.709999 56.099999) (xy 151.664042 56.155998) (xy 151.615026 56.215724) + (xy 151.55799 56.322431) (xy 151.544454 56.347754) (xy 151.500997 56.491015) (xy 151.49 56.602668) (xy 151.49 56.602678) + (xy 151.486324 56.64) (xy 151.49 56.677323) (xy 151.49 58.568605) (xy 151.398986 58.540997) (xy 151.352874 58.536455) + (xy 151.350812 58.515518) (xy 151.314502 58.39582) (xy 151.255537 58.285506) (xy 151.176185 58.188815) (xy 151.079494 58.109463) + (xy 150.96918 58.050498) (xy 150.849482 58.014188) (xy 150.725 58.001928) (xy 149.775 58.001928) (xy 149.650518 58.014188) + (xy 149.53082 58.050498) (xy 149.420506 58.109463) (xy 149.323815 58.188815) (xy 149.244463 58.285506) (xy 149.185498 58.39582) + (xy 149.149188 58.515518) (xy 149.147762 58.53) (xy 148.036722 58.53) (xy 147.999399 58.526324) (xy 147.962076 58.53) + (xy 147.962067 58.53) (xy 147.850414 58.540997) (xy 147.720801 58.580314) (xy 147.707153 58.584454) (xy 147.575123 58.655026) + (xy 147.510867 58.70776) (xy 147.459399 58.749999) (xy 147.435601 58.778997) (xy 146.615001 59.599598) (xy 146.615001 58.128483) + (xy 146.74356 58.102911) (xy 146.847157 58.06) (xy 147.852678 58.06) (xy 147.89 58.063676) (xy 147.927322 58.06) + (xy 147.927333 58.06) (xy 148.038986 58.049003) (xy 148.182247 58.005546) (xy 148.314276 57.934974) (xy 148.430001 57.840001) + (xy 148.453803 57.810998) (xy 149.541925 56.722878) (xy 149.645521 56.679967) (xy 149.782281 56.588587) (xy 149.898587 56.472281) + (xy 149.989967 56.335521) (xy 150.052911 56.18356) (xy 150.085 56.02224) (xy 150.085 55.85776) (xy 150.052911 55.69644) + (xy 149.989967 55.544479) (xy 149.898587 55.407719) (xy 149.782281 55.291413) (xy 149.645521 55.200033) (xy 149.49356 55.137089) + (xy 149.33224 55.105) (xy 149.16776 55.105) (xy 149.00644 55.137089) (xy 148.854479 55.200033) (xy 148.717719 55.291413) + (xy 148.601413 55.407719) (xy 148.510033 55.544479) (xy 148.467122 55.648075) (xy 147.575199 56.54) (xy 146.847157 56.54) + (xy 146.74356 56.497089) (xy 146.617012 56.471917) (xy 146.618678 56.455001) (xy 146.604004 56.306015) (xy 146.560547 56.162754) + (xy 146.489975 56.030725) (xy 146.421891 55.947764) (xy 146.395002 55.915) (xy 146.366005 55.891203) (xy 145.082879 54.608078) + (xy 145.06 54.552843) (xy 145.06 54.258072) (xy 146.35 54.258072) (xy 146.474482 54.245812) (xy 146.59418 54.209502) + (xy 146.704494 54.150537) (xy 146.801185 54.071185) (xy 146.880537 53.974494) (xy 146.939502 53.86418) (xy 146.975812 53.744482) + (xy 146.988072 53.62) (xy 146.988072 51.62) (xy 146.975812 51.495518) (xy 146.939502 51.37582) (xy 146.880537 51.265506) + (xy 146.801185 51.168815) (xy 146.704494 51.089463) (xy 146.59418 51.030498) (xy 146.474482 50.994188) (xy 146.35 50.981928) + (xy 145.230748 50.981928) (xy 145.362953 50.662756) (xy 145.445 50.250279) (xy 145.445 49.829721) (xy 145.362953 49.417244) + (xy 145.202012 49.028698) (xy 145.164985 48.973283) (xy 145.330779 48.904609) (xy 145.590379 48.73115) (xy 145.81115 48.510379) + (xy 145.984609 48.250779) (xy 146.104089 47.962327) (xy 146.165 47.656109) (xy 146.165 47.343891) (xy 146.104089 47.037673) + (xy 145.984609 46.749221) (xy 145.81115 46.489621) (xy 145.590379 46.26885) (xy 145.330779 46.095391) (xy 145.042327 45.975911) + (xy 144.736109 45.915) (xy 144.423891 45.915) (xy 144.117673 45.975911) (xy 144.023303 46.015) (xy 143.85374 46.015) + (xy 143.566842 46.072068) (xy 143.296589 46.18401) (xy 143.053368 46.346525) (xy 142.846525 46.553368) (xy 142.68401 46.796589) + (xy 142.572068 47.066842) (xy 142.515 47.35374) (xy 142.515 47.64626) (xy 142.572068 47.933158) (xy 142.607988 48.019876) + (xy 142.298698 48.147988) (xy 142.076252 48.296622) (xy 142.081817 48.283186) (xy 142.185 47.764449) (xy 142.185 47.235551) + (xy 142.081817 46.716814) (xy 141.879417 46.228175) (xy 141.585576 45.788412) (xy 141.557172 45.760008) (xy 147.68517 45.760008) + (xy 147.722492 45.763684) (xy 147.759814 45.760008) (xy 147.759825 45.760008) (xy 147.871478 45.749011) (xy 148.014739 45.705554) + (xy 148.146768 45.634982) (xy 148.262493 45.540009) (xy 148.286296 45.511005) (xy 149.386928 44.410373) + ) + ) + (filled_polygon + (pts + (xy 116.661928 45.31173) (xy 116.661928 45.875) (xy 116.674188 45.999482) (xy 116.710498 46.11918) (xy 116.769463 46.229494) + (xy 116.848815 46.326185) (xy 116.945506 46.405537) (xy 117.05582 46.464502) (xy 117.175518 46.500812) (xy 117.3 46.513072) + (xy 118.04 46.513072) (xy 118.04 46.715123) (xy 118.036565 46.75) (xy 118.050273 46.889184) (xy 118.090872 47.02302) + (xy 118.099948 47.04) (xy 114.960323 47.04) (xy 114.922998 47.036324) (xy 114.885673 47.04) (xy 114.885665 47.04) + (xy 114.774012 47.050997) (xy 114.630751 47.094454) (xy 114.498722 47.165026) (xy 114.382997 47.259999) (xy 114.359199 47.288997) + (xy 111.388998 50.259199) (xy 111.36 50.282997) (xy 111.336202 50.311995) (xy 111.336201 50.311996) (xy 111.265026 50.398722) + (xy 111.194454 50.530752) (xy 111.175554 50.59306) (xy 111.150998 50.674012) (xy 111.144236 50.742667) (xy 111.136324 50.822998) + (xy 111.140001 50.86033) (xy 111.14 58.448386) (xy 110.142642 59.445745) (xy 109.891156 59.445745) (xy 109.803935 59.31521) + (xy 109.60935 59.120625) (xy 109.380542 58.96774) (xy 109.3033 58.935745) (xy 109.380542 58.90375) (xy 109.60935 58.750865) + (xy 109.803935 58.55628) (xy 109.95682 58.327472) (xy 110.062129 58.073235) (xy 110.115815 57.803337) (xy 110.115815 57.528153) + (xy 110.062129 57.258255) (xy 109.95682 57.004018) (xy 109.803935 56.77521) (xy 109.60935 56.580625) (xy 109.380542 56.42774) + (xy 109.3033 56.395745) (xy 109.380542 56.36375) (xy 109.60935 56.210865) (xy 109.803935 56.01628) (xy 109.95682 55.787472) + (xy 110.062129 55.533235) (xy 110.115815 55.263337) (xy 110.115815 54.988153) (xy 110.062129 54.718255) (xy 109.95682 54.464018) + (xy 109.803935 54.23521) (xy 109.60935 54.040625) (xy 109.380542 53.88774) (xy 109.3033 53.855745) (xy 109.380542 53.82375) + (xy 109.60935 53.670865) (xy 109.803935 53.47628) (xy 109.95682 53.247472) (xy 110.062129 52.993235) (xy 110.115815 52.723337) + (xy 110.115815 52.448153) (xy 110.062129 52.178255) (xy 109.95682 51.924018) (xy 109.803935 51.69521) (xy 109.60935 51.500625) + (xy 109.380542 51.34774) (xy 109.308872 51.318053) (xy 109.321838 51.313381) (xy 109.437795 51.251401) (xy 109.504775 51.01131) + (xy 108.718815 50.22535) (xy 108.704673 50.239493) (xy 108.525068 50.059888) (xy 108.53921 50.045745) (xy 108.89842 50.045745) + (xy 109.68438 50.831705) (xy 109.924471 50.764725) (xy 110.041571 50.515697) (xy 110.107838 50.24861) (xy 110.120725 49.973728) + (xy 110.079737 49.701612) (xy 109.986451 49.442722) (xy 109.924471 49.326765) (xy 109.68438 49.259785) (xy 108.89842 50.045745) + (xy 108.53921 50.045745) (xy 108.525068 50.031603) (xy 108.704673 49.851998) (xy 108.718815 49.86614) (xy 109.504775 49.08018) + (xy 109.437795 48.840089) (xy 109.307171 48.778666) (xy 109.321838 48.773381) (xy 109.437795 48.711401) (xy 109.502599 48.479109) + (xy 109.51059 48.494059) (xy 109.621183 48.628817) (xy 109.755941 48.73941) (xy 109.909687 48.821588) (xy 110.07651 48.872195) + (xy 110.25 48.889281) (xy 110.42349 48.872195) (xy 110.590313 48.821588) (xy 110.744059 48.73941) (xy 110.845046 48.656532) + (xy 112.381532 47.120047) (xy 112.381536 47.120042) (xy 114.116579 45.385) (xy 115.956531 45.385) (xy 116 45.389281) + (xy 116.043469 45.385) (xy 116.043477 45.385) (xy 116.17349 45.372195) (xy 116.340313 45.321589) (xy 116.494059 45.239411) + (xy 116.54654 45.196341) + ) + ) + (filled_polygon + (pts + (xy 160.344302 48.098682) (xy 160.128698 48.187988) (xy 159.779017 48.421637) (xy 159.481637 48.719017) (xy 159.247988 49.068698) + (xy 159.087047 49.457244) (xy 159.005 49.869721) (xy 159.005 50.290279) (xy 159.087047 50.702756) (xy 159.247988 51.091302) + (xy 159.481637 51.440983) (xy 159.779017 51.738363) (xy 159.836734 51.776928) (xy 159.7 51.776928) (xy 159.575518 51.789188) + (xy 159.45582 51.825498) (xy 159.345506 51.884463) (xy 159.248815 51.963815) (xy 159.169463 52.060506) (xy 159.110498 52.17082) + (xy 159.074188 52.290518) (xy 159.061928 52.415) (xy 159.061928 52.955) (xy 158.91776 52.955) (xy 158.75644 52.987089) + (xy 158.604479 53.050033) (xy 158.467719 53.141413) (xy 158.351413 53.257719) (xy 158.260033 53.394479) (xy 158.197089 53.54644) + (xy 158.165 53.70776) (xy 158.165 53.87224) (xy 158.197089 54.03356) (xy 158.24 54.137157) (xy 158.24 54.187678) + (xy 158.236324 54.225) (xy 158.24 54.262322) (xy 158.24 54.262333) (xy 158.250997 54.373986) (xy 158.294454 54.517247) + (xy 158.365026 54.649276) (xy 158.431275 54.73) (xy 156.153 54.73) (xy 156.153 54.538) (xy 156.173 54.538) + (xy 156.173 54.518) (xy 156.427 54.518) (xy 156.427 54.538) (xy 157.77625 54.538) (xy 157.935 54.37925) + (xy 157.938072 54.165) (xy 157.925812 54.040518) (xy 157.889502 53.92082) (xy 157.830537 53.810506) (xy 157.813708 53.79) + (xy 157.830537 53.769494) (xy 157.889502 53.65918) (xy 157.925812 53.539482) (xy 157.938072 53.415) (xy 157.938072 52.415) + (xy 157.925812 52.290518) (xy 157.889502 52.17082) (xy 157.830537 52.060506) (xy 157.751185 51.963815) (xy 157.654494 51.884463) + (xy 157.54418 51.825498) (xy 157.424482 51.789188) (xy 157.355139 51.782359) (xy 157.420983 51.738363) (xy 157.718363 51.440983) + (xy 157.952012 51.091302) (xy 158.112953 50.702756) (xy 158.195 50.290279) (xy 158.195 49.869721) (xy 158.112953 49.457244) + (xy 157.952012 49.068698) (xy 157.718363 48.719017) (xy 157.420983 48.421637) (xy 157.071302 48.187988) (xy 156.855698 48.098682) + (xy 156.897651 47.887772) (xy 156.919998 47.915002) (xy 156.948991 47.938796) (xy 156.948995 47.9388) (xy 156.999862 47.980545) + (xy 157.035723 48.009975) (xy 157.167752 48.080547) (xy 157.311013 48.124004) (xy 157.422666 48.135001) (xy 157.422675 48.135001) + (xy 157.459998 48.138677) (xy 157.497321 48.135001) (xy 159.702679 48.135001) (xy 159.740001 48.138677) (xy 159.777323 48.135001) + (xy 159.777334 48.135001) (xy 159.888987 48.124004) (xy 160.032248 48.080547) (xy 160.164277 48.009975) (xy 160.280002 47.915002) + (xy 160.302349 47.887772) + ) + ) + (filled_polygon + (pts + (xy 153.429017 49.198364) (xy 153.778698 49.432013) (xy 153.994302 49.521319) (xy 153.925 49.869721) (xy 153.925 50.290279) + (xy 154.007047 50.702756) (xy 154.167988 51.091302) (xy 154.401637 51.440983) (xy 154.699017 51.738363) (xy 154.933014 51.894715) + (xy 154.848815 51.963815) (xy 154.769463 52.060506) (xy 154.710498 52.17082) (xy 154.69949 52.207107) (xy 154.691753 52.209454) + (xy 154.559724 52.280026) (xy 154.443999 52.374999) (xy 154.420199 52.404) (xy 153.989003 52.835196) (xy 153.959999 52.858999) + (xy 153.9163 52.912247) (xy 153.865026 52.974724) (xy 153.825865 53.047989) (xy 153.794454 53.106754) (xy 153.750997 53.250015) + (xy 153.74 53.361668) (xy 153.74 53.361678) (xy 153.736324 53.399) (xy 153.74 53.436322) (xy 153.74 53.442843) + (xy 153.697089 53.54644) (xy 153.673689 53.664076) (xy 151.31 51.300387) (xy 151.31 49.987157) (xy 151.352911 49.88356) + (xy 151.385 49.72224) (xy 151.385 49.55776) (xy 151.352911 49.39644) (xy 151.31 49.292843) (xy 151.31 49.218072) + (xy 152.75 49.218072) (xy 152.874482 49.205812) (xy 152.99418 49.169502) (xy 153.104494 49.110537) (xy 153.201185 49.031185) + (xy 153.228525 48.997872) + ) + ) + (filled_polygon + (pts + (xy 192.35597 45.332549) (xy 192.383683 45.366317) (xy 192.417451 45.39403) (xy 192.417453 45.394032) (xy 192.467373 45.435) + (xy 192.518441 45.476911) (xy 192.672187 45.559089) (xy 192.83901 45.609695) (xy 192.861928 45.611952) (xy 192.861928 45.915) + (xy 192.71776 45.915) (xy 192.55644 45.947089) (xy 192.404479 46.010033) (xy 192.267719 46.101413) (xy 192.151413 46.217719) + (xy 192.060033 46.354479) (xy 191.997089 46.50644) (xy 191.993706 46.523449) (xy 191.965764 46.575724) (xy 191.953454 46.598754) + (xy 191.909997 46.742015) (xy 191.899 46.853668) (xy 191.899 46.853678) (xy 191.895324 46.891) (xy 191.899 46.928323) + (xy 191.899001 47.871668) (xy 191.895324 47.909) (xy 191.899001 47.946333) (xy 191.909998 48.057986) (xy 191.920391 48.092247) + (xy 191.953454 48.201246) (xy 192.024026 48.333276) (xy 192.086971 48.409974) (xy 192.119 48.449001) (xy 192.147998 48.472799) + (xy 192.915198 49.24) (xy 189.101746 49.24) (xy 189.113072 49.125) (xy 189.113072 47.825) (xy 189.100812 47.700518) + (xy 189.064502 47.58082) (xy 189.005537 47.470506) (xy 188.926185 47.373815) (xy 188.829494 47.294463) (xy 188.71918 47.235498) + (xy 188.599482 47.199188) (xy 188.475 47.186928) (xy 188.4749 47.186928) (xy 188.532281 47.148587) (xy 188.648587 47.032281) + (xy 188.739967 46.895521) (xy 188.802911 46.74356) (xy 188.835 46.58224) (xy 188.835 46.41776) (xy 188.802911 46.25644) + (xy 188.739967 46.104479) (xy 188.648587 45.967719) (xy 188.532281 45.851413) (xy 188.395521 45.760033) (xy 188.291924 45.717122) + (xy 182.7098 40.134999) (xy 187.158421 40.134999) + ) + ) + (filled_polygon + (pts + (xy 106.181995 46.971727) (xy 106.33488 47.200535) (xy 106.529465 47.39512) (xy 106.758273 47.548005) (xy 106.835515 47.58) + (xy 106.758273 47.611995) (xy 106.529465 47.76488) (xy 106.33488 47.959465) (xy 106.181995 48.188273) (xy 106.076686 48.44251) + (xy 106.023 48.712408) (xy 106.023 48.987592) (xy 106.024299 48.994123) (xy 105.857677 49.160745) (xy 94.567633 49.160745) + (xy 94.563935 49.15521) (xy 94.36935 48.960625) (xy 94.140542 48.80774) (xy 94.0633 48.775745) (xy 94.140542 48.74375) + (xy 94.36935 48.590865) (xy 94.563935 48.39628) (xy 94.651156 48.265745) (xy 104.356933 48.265745) (xy 104.394255 48.269421) + (xy 104.431577 48.265745) (xy 104.431588 48.265745) (xy 104.543241 48.254748) (xy 104.686502 48.211291) (xy 104.818531 48.140719) + (xy 104.934256 48.045746) (xy 104.958059 48.016742) (xy 106.014802 46.96) (xy 106.177137 46.96) + ) + ) + (filled_polygon + (pts + (xy 205.499941 45.113211) (xy 205.653687 45.195389) (xy 205.82051 45.245995) (xy 205.950523 45.2588) (xy 205.950533 45.2588) + (xy 205.993999 45.263081) (xy 206.037465 45.2588) (xy 209.407222 45.2588) (xy 209.548712 45.40029) (xy 209.404479 45.460033) + (xy 209.267719 45.551413) (xy 209.151413 45.667719) (xy 209.060033 45.804479) (xy 209.017121 45.908078) (xy 209.003299 45.9219) + (xy 207.553033 45.9219) (xy 207.515708 45.918224) (xy 207.478383 45.9219) (xy 207.478375 45.9219) (xy 207.366722 45.932897) + (xy 207.223461 45.976354) (xy 207.091432 46.046926) (xy 206.975707 46.141899) (xy 206.951908 46.170898) (xy 206.468459 46.654348) + (xy 206.406006 46.705601) (xy 206.406002 46.705605) (xy 206.377009 46.729399) (xy 206.353215 46.758392) (xy 204.321609 48.79) + (xy 200.273426 48.79) (xy 200.351185 48.726185) (xy 200.430537 48.629494) (xy 200.489502 48.51918) (xy 200.525812 48.399482) + (xy 200.538072 48.275) (xy 200.535 48.06075) (xy 200.376252 47.902002) (xy 200.535 47.902002) (xy 200.535 47.808592) + (xy 200.66776 47.835) (xy 200.83224 47.835) (xy 200.99356 47.802911) (xy 201.145521 47.739967) (xy 201.282281 47.648587) + (xy 201.398587 47.532281) (xy 201.489967 47.395521) (xy 201.552911 47.24356) (xy 201.585 47.08224) (xy 201.585 46.91776) + (xy 201.552911 46.75644) (xy 201.51 46.652843) (xy 201.51 46.482325) (xy 201.513676 46.445) (xy 201.51 46.407675) + (xy 201.51 46.407667) (xy 201.499003 46.296014) (xy 201.455546 46.152753) (xy 201.384974 46.020724) (xy 201.290001 45.904999) + (xy 201.260998 45.881197) (xy 200.893804 45.514003) (xy 200.870001 45.484999) (xy 200.754276 45.390026) (xy 200.622247 45.319454) + (xy 200.48846 45.278871) (xy 200.430537 45.170506) (xy 200.351185 45.073815) (xy 200.273414 45.00999) (xy 205.374167 45.00999) + ) + ) + (filled_polygon + (pts + (xy 199.227 47.648) (xy 199.247 47.648) (xy 199.247 47.902) (xy 199.227 47.902) (xy 199.227 47.922) + (xy 199.16 47.922) (xy 199.16 47.628) (xy 199.227 47.628) + ) + ) + (filled_polygon + (pts + (xy 123.18575 46.51) (xy 123.7 46.513072) (xy 123.768914 46.506285) (xy 123.235199 47.04) (xy 122.900052 47.04) + (xy 122.909128 47.02302) (xy 122.949727 46.889184) (xy 122.96 46.784877) (xy 122.96 46.784876) (xy 122.963435 46.75) + (xy 122.96 46.715123) (xy 122.96 46.51) (xy 123.027002 46.51) (xy 123.027002 46.351252) + ) + ) + (filled_polygon + (pts + (xy 124.667122 44.591925) (xy 124.710033 44.695523) (xy 124.801413 44.832283) (xy 124.917719 44.948589) (xy 125.054479 45.039969) + (xy 125.182288 45.092909) (xy 124.331285 45.943913) (xy 124.338072 45.875) (xy 124.335 45.66075) (xy 124.17625 45.502) + (xy 123.027 45.502) (xy 123.027 45.522) (xy 122.96 45.522) (xy 122.96 45.228) (xy 123.027 45.228) + (xy 123.027 45.248) (xy 124.17625 45.248) (xy 124.335 45.08925) (xy 124.338072 44.875) (xy 124.325812 44.750518) + (xy 124.289502 44.63082) (xy 124.230537 44.520506) (xy 124.213708 44.5) (xy 124.230537 44.479494) (xy 124.281046 44.385) + (xy 124.460197 44.385) + ) + ) + (filled_polygon + (pts + (xy 151.226699 39.79277) (xy 151.226699 39.95725) (xy 151.242784 40.038115) (xy 151.21918 40.025498) (xy 151.099482 39.989188) + (xy 150.975 39.976928) (xy 150.025 39.976928) (xy 149.900518 39.989188) (xy 149.78082 40.025498) (xy 149.670506 40.084463) + (xy 149.573815 40.163815) (xy 149.494463 40.260506) (xy 149.435498 40.37082) (xy 149.399188 40.490518) (xy 149.386928 40.615) + (xy 149.386928 41.915) (xy 149.399188 42.039482) (xy 149.435498 42.15918) (xy 149.453967 42.193732) (xy 147.407691 44.240008) + (xy 141.962608 44.240008) (xy 141.96 44.213523) (xy 141.96 44.01) (xy 142.027002 44.01) (xy 142.027002 43.851252) + (xy 142.18575 44.01) (xy 142.7 44.013072) (xy 142.824482 44.000812) (xy 142.94418 43.964502) (xy 143.054494 43.905537) + (xy 143.151185 43.826185) (xy 143.230537 43.729494) (xy 143.289502 43.61918) (xy 143.325812 43.499482) (xy 143.338072 43.375) + (xy 143.335 43.16075) (xy 143.17625 43.002) (xy 142.027 43.002) (xy 142.027 43.022) (xy 141.96 43.022) + (xy 141.96 42.728) (xy 142.027 42.728) (xy 142.027 42.748) (xy 143.17625 42.748) (xy 143.298877 42.625373) + (xy 143.322613 42.625373) (xy 143.483933 42.593284) (xy 143.635894 42.53034) (xy 143.772654 42.43896) (xy 143.88896 42.322654) + (xy 143.98034 42.185894) (xy 144.043284 42.033933) (xy 144.075373 41.872613) (xy 144.075373 41.708133) (xy 144.043284 41.546813) + (xy 144.000373 41.443216) (xy 144.000373 41.398306) (xy 144.00405 41.360973) (xy 143.989376 41.211987) (xy 143.945919 41.068726) + (xy 143.923354 41.02651) (xy 143.875347 40.936697) (xy 143.780374 40.820972) (xy 143.751371 40.79717) (xy 143.468204 40.514003) + (xy 143.444401 40.484999) (xy 143.328676 40.390026) (xy 143.280722 40.364394) (xy 143.230537 40.270506) (xy 143.151185 40.173815) + (xy 143.054494 40.094463) (xy 142.94418 40.035498) (xy 142.824482 39.999188) (xy 142.7 39.986928) (xy 141.96 39.986928) + (xy 141.96 39.783277) (xy 141.963435 39.7484) (xy 141.952266 39.635) (xy 151.258082 39.635) + ) + ) + (filled_polygon + (pts + (xy 167.154953 39.196532) (xy 167.255941 39.279411) (xy 167.409686 39.361588) (xy 167.424505 39.366083) (xy 168.29168 40.233259) + (xy 168.319393 40.267027) (xy 168.353161 40.29474) (xy 168.353163 40.294742) (xy 168.411857 40.342911) (xy 168.454151 40.377621) + (xy 168.607897 40.459799) (xy 168.77472 40.510405) (xy 168.904733 40.52321) (xy 168.904741 40.52321) (xy 168.94821 40.527491) + (xy 168.991679 40.52321) (xy 173.771953 40.52321) (xy 173.761928 40.625) (xy 173.761928 40.878957) (xy 173.343263 41.297623) + (xy 173.290943 41.325588) (xy 173.257638 41.35292) (xy 173.24356 41.347089) (xy 173.08224 41.315) (xy 172.91776 41.315) + (xy 172.75644 41.347089) (xy 172.604479 41.410033) (xy 172.467719 41.501413) (xy 172.351413 41.617719) (xy 172.260033 41.754479) + (xy 172.197089 41.90644) (xy 172.165 42.06776) (xy 172.165 42.23224) (xy 172.197089 42.39356) (xy 172.260033 42.545521) + (xy 172.351413 42.682281) (xy 172.467719 42.798587) (xy 172.604479 42.889967) (xy 172.708077 42.932879) (xy 173.161201 43.386002) + (xy 173.184999 43.415001) (xy 173.300724 43.509974) (xy 173.432753 43.580546) (xy 173.533936 43.611239) (xy 172.743563 43.611239) + (xy 170.590526 41.458202) (xy 170.566723 41.429198) (xy 170.450998 41.334225) (xy 170.318969 41.263653) (xy 170.175708 41.220196) + (xy 170.064055 41.209199) (xy 170.064045 41.209199) (xy 170.026722 41.205523) (xy 169.9894 41.209199) (xy 162.453321 41.209199) + (xy 162.415998 41.205523) (xy 162.378676 41.209199) (xy 162.378666 41.209199) (xy 162.339313 41.213075) (xy 162.389502 41.11918) + (xy 162.425812 40.999482) (xy 162.438072 40.875) (xy 162.435 40.66075) (xy 162.276252 40.502002) (xy 162.435 40.502002) + (xy 162.435 40.375) (xy 162.582256 40.375) (xy 162.743576 40.342911) (xy 162.895537 40.279967) (xy 163.032297 40.188587) + (xy 163.148603 40.072281) (xy 163.239983 39.935521) (xy 163.302927 39.78356) (xy 163.335016 39.62224) (xy 163.335016 39.45776) + (xy 163.302927 39.29644) (xy 163.260016 39.192843) (xy 163.260016 39.156838) (xy 163.263692 39.119515) (xy 163.260016 39.082192) + (xy 163.260016 39.082183) (xy 163.249019 38.97053) (xy 163.205562 38.827269) (xy 163.13499 38.69524) (xy 163.040017 38.579515) + (xy 163.011014 38.555713) (xy 162.569304 38.114003) (xy 162.545501 38.084999) (xy 162.429776 37.990026) (xy 162.421246 37.985467) + (xy 162.389502 37.88082) (xy 162.330537 37.770506) (xy 162.251185 37.673815) (xy 162.154494 37.594463) (xy 162.04418 37.535498) + (xy 161.928738 37.500479) (xy 165.458901 37.500479) + ) + ) + (filled_polygon + (pts + (xy 181.744291 42.894093) (xy 181.435603 43.202782) (xy 181.435 43.16075) (xy 181.27625 43.002) (xy 180.127 43.002) + (xy 180.127 43.022) (xy 180.06 43.022) (xy 180.06 42.728) (xy 180.127 42.728) (xy 180.127 42.748) + (xy 181.27625 42.748) (xy 181.435 42.58925) (xy 181.435063 42.584864) + ) + ) + (filled_polygon + (pts + (xy 161.190739 41.414989) (xy 161.127002 41.414989) (xy 161.127002 41.351252) + ) + ) + (filled_polygon + (pts + (xy 161.127 40.248) (xy 161.147 40.248) (xy 161.147 40.502) (xy 161.127 40.502) (xy 161.127 40.522) + (xy 161.06 40.522) (xy 161.06 40.228) (xy 161.127 40.228) + ) + ) + ) + (zone (net 34) (net_name GND) (layer B.Cu) (tstamp 6039FDAA) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508)) + (polygon + (pts + (xy 80.85 127.25) (xy 92.6 147.85) (xy 138.1 134.85) (xy 187.45 135.3) (xy 226.6 121.7) + (xy 225.8 43.3) (xy 171.5 34.2) (xy 87.6 36.9) (xy 87.95 114.65) + ) + ) + (filled_polygon + (pts + (xy 224.336807 44.116746) (xy 224.447617 44.145115) (xy 224.521481 44.178972) (xy 224.587585 44.224767) (xy 224.644771 44.281261) + (xy 224.691436 44.346768) (xy 224.726105 44.419343) (xy 224.747732 44.497657) (xy 224.758192 44.613012) (xy 224.785002 119.001646) + (xy 215.337562 122.609422) (xy 214.544604 120.543696) (xy 187.343182 130.985343) (xy 188.11806 133.003968) (xy 187.30358 133.315) + (xy 138.158838 133.315) (xy 138.096265 133.314123) (xy 138.058284 133.321126) (xy 138.019845 133.324912) (xy 137.959927 133.343088) + (xy 93.864605 146.047335) (xy 93.520432 145.984758) (xy 93.243912 145.892584) (xy 93.08499 145.756366) (xy 82.933274 128.127044) + (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583074 116.011918) + (xy 88.59798 115.990873) (xy 88.615021 115.952706) (xy 88.618829 115.945648) (xy 88.62876 115.921935) (xy 88.639207 115.898536) + (xy 88.641735 115.890952) (xy 88.657891 115.852374) (xy 88.663024 115.827087) (xy 88.84031 115.29523) (xy 88.855164 115.261034) + (xy 88.868713 115.198522) (xy 88.882908 115.13609) (xy 88.883923 115.098817) (xy 88.948633 114.539922) (xy 88.950347 114.53427) + (xy 88.956379 114.473019) (xy 88.959581 114.44536) (xy 88.959682 114.439478) (xy 88.960257 114.433634) (xy 88.960256 114.405836) + (xy 88.961309 114.344252) (xy 88.960255 114.338437) (xy 88.96016 109.1) (xy 97.761928 109.1) (xy 97.761928 111.1) + (xy 97.774188 111.224482) (xy 97.810498 111.34418) (xy 97.869463 111.454494) (xy 97.948815 111.551185) (xy 98.045506 111.630537) + (xy 98.15582 111.689502) (xy 98.275518 111.725812) (xy 98.4 111.738072) (xy 101.6 111.738072) (xy 101.724482 111.725812) + (xy 101.84418 111.689502) (xy 101.954494 111.630537) (xy 102.051185 111.551185) (xy 102.130537 111.454494) (xy 102.189502 111.34418) + (xy 102.225812 111.224482) (xy 102.238072 111.1) (xy 102.238072 109.1) (xy 102.225812 108.975518) (xy 102.189502 108.85582) + (xy 102.130537 108.745506) (xy 102.051185 108.648815) (xy 101.954494 108.569463) (xy 101.84418 108.510498) (xy 101.724482 108.474188) + (xy 101.6 108.461928) (xy 98.4 108.461928) (xy 98.275518 108.474188) (xy 98.15582 108.510498) (xy 98.045506 108.569463) + (xy 97.948815 108.648815) (xy 97.869463 108.745506) (xy 97.810498 108.85582) (xy 97.774188 108.975518) (xy 97.761928 109.1) + (xy 88.96016 109.1) (xy 88.960076 104.562595) (xy 90.858282 104.562595) (xy 90.902039 104.881675) (xy 91.007205 105.186088) + (xy 91.100186 105.360044) (xy 91.364587 105.455808) (xy 92.320395 104.5) (xy 91.364587 103.544192) (xy 91.100186 103.639956) + (xy 90.959296 103.929571) (xy 90.877616 104.241108) (xy 90.858282 104.562595) (xy 88.960076 104.562595) (xy 88.959885 94.236545) + (xy 88.966261 94.268601) (xy 89.164893 94.748141) (xy 89.453262 95.179715) (xy 89.820285 95.546738) (xy 90.251859 95.835107) + (xy 90.731399 96.033739) (xy 91.240475 96.135) (xy 91.759525 96.135) (xy 92.268601 96.033739) (xy 92.748141 95.835107) + (xy 93.179715 95.546738) (xy 93.546738 95.179715) (xy 93.835107 94.748141) (xy 94.033739 94.268601) (xy 94.135 93.759525) + (xy 94.135 93.240475) (xy 94.033739 92.731399) (xy 93.835107 92.251859) (xy 93.546738 91.820285) (xy 93.179715 91.453262) + (xy 92.748141 91.164893) (xy 92.268601 90.966261) (xy 92.095535 90.931836) (xy 92.271034 90.878599) (xy 92.529014 90.740706) + (xy 92.755134 90.555134) (xy 92.800624 90.499705) (xy 92.969381 90.664176) (xy 93.214382 90.823361) (xy 93.485731 90.93169) + (xy 93.773 90.985) (xy 94.173 90.985) (xy 94.173 89.627) (xy 94.427 89.627) (xy 94.427 90.985) + (xy 94.827 90.985) (xy 95.114269 90.93169) (xy 95.385618 90.823361) (xy 95.630619 90.664176) (xy 95.839857 90.460252) + (xy 96.005291 90.219426) (xy 96.120563 89.950953) (xy 96.141476 89.85689) (xy 96.020155 89.627) (xy 94.427 89.627) + (xy 94.173 89.627) (xy 94.153 89.627) (xy 94.153 89.373) (xy 94.173 89.373) (xy 94.173 88.015) + (xy 94.427 88.015) (xy 94.427 89.373) (xy 96.020155 89.373) (xy 96.141476 89.14311) (xy 96.120563 89.049047) + (xy 96.005291 88.780574) (xy 95.839857 88.539748) (xy 95.630619 88.335824) (xy 95.385618 88.176639) (xy 95.114269 88.06831) + (xy 94.827 88.015) (xy 94.427 88.015) (xy 94.173 88.015) (xy 93.773 88.015) (xy 93.485731 88.06831) + (xy 93.214382 88.176639) (xy 92.969381 88.335824) (xy 92.800624 88.500295) (xy 92.755134 88.444866) (xy 92.529014 88.259294) + (xy 92.271034 88.121401) (xy 91.991111 88.036487) (xy 91.77295 88.015) (xy 90.82705 88.015) (xy 90.608889 88.036487) + (xy 90.547616 88.055074) (xy 90.594443 87.984992) (xy 90.68754 87.760236) (xy 90.735 87.521637) (xy 90.735 87.278363) + (xy 90.68754 87.039764) (xy 90.594443 86.815008) (xy 90.459287 86.612733) (xy 90.371554 86.525) (xy 90.459287 86.437267) + (xy 90.594443 86.234992) (xy 90.68754 86.010236) (xy 90.735 85.771637) (xy 90.735 85.528363) (xy 90.68754 85.289764) + (xy 90.594443 85.065008) (xy 90.547616 84.994926) (xy 90.608889 85.013513) (xy 90.82705 85.035) (xy 91.77295 85.035) + (xy 91.991111 85.013513) (xy 92.271034 84.928599) (xy 92.529014 84.790706) (xy 92.755134 84.605134) (xy 92.800624 84.549705) + (xy 92.969381 84.714176) (xy 93.214382 84.873361) (xy 93.485731 84.98169) (xy 93.773 85.035) (xy 94.173 85.035) + (xy 94.173 83.677) (xy 94.427 83.677) (xy 94.427 85.035) (xy 94.827 85.035) (xy 95.114269 84.98169) + (xy 95.385618 84.873361) (xy 95.630619 84.714176) (xy 95.839857 84.510252) (xy 96.005291 84.269426) (xy 96.120563 84.000953) + (xy 96.141476 83.90689) (xy 96.020155 83.677) (xy 94.427 83.677) (xy 94.173 83.677) (xy 94.153 83.677) + (xy 94.153 83.423) (xy 94.173 83.423) (xy 94.173 82.065) (xy 93.773 82.065) (xy 93.485731 82.11831) + (xy 93.214382 82.226639) (xy 92.969381 82.385824) (xy 92.800624 82.550295) (xy 92.755134 82.494866) (xy 92.529014 82.309294) + (xy 92.271034 82.171401) (xy 91.991111 82.086487) (xy 91.77295 82.065) (xy 90.974885 82.065) (xy 91.042252 82.019987) + (xy 91.269987 81.792252) (xy 91.448918 81.524463) (xy 91.572168 81.226912) (xy 91.635 80.911033) (xy 91.635 80.588967) + (xy 91.572168 80.273088) (xy 91.448918 79.975537) (xy 91.269987 79.707748) (xy 91.042252 79.480013) (xy 90.774463 79.301082) + (xy 90.476912 79.177832) (xy 90.161033 79.115) (xy 89.838967 79.115) (xy 89.523088 79.177832) (xy 89.508624 79.183823) + (xy 89.434999 79.110198) (xy 89.434999 75.792127) (xy 89.741108 75.872384) (xy 90.062595 75.891718) (xy 90.381675 75.847961) + (xy 90.686088 75.742795) (xy 90.860044 75.649814) (xy 90.955808 75.385413) (xy 90 74.429605) (xy 89.985858 74.443748) + (xy 89.806253 74.264143) (xy 89.820395 74.25) (xy 90.179605 74.25) (xy 91.135413 75.205808) (xy 91.399814 75.110044) + (xy 91.540704 74.820429) (xy 91.622384 74.508892) (xy 91.641718 74.187405) (xy 91.597961 73.868325) (xy 91.492795 73.563912) + (xy 91.399814 73.389956) (xy 91.135413 73.294192) (xy 90.179605 74.25) (xy 89.820395 74.25) (xy 89.806253 74.235858) + (xy 89.985858 74.056253) (xy 90 74.070395) (xy 90.955808 73.114587) (xy 90.860044 72.850186) (xy 90.570429 72.709296) + (xy 90.258892 72.627616) (xy 89.937405 72.608282) (xy 89.618325 72.652039) (xy 89.434999 72.715373) (xy 89.434999 51.06104) + (xy 90.957874 49.538166) (xy 90.974344 49.56898) (xy 91.214435 49.63596) (xy 92.000395 48.85) (xy 91.986253 48.835858) + (xy 92.165858 48.656253) (xy 92.18 48.670395) (xy 92.194143 48.656253) (xy 92.373748 48.835858) (xy 92.359605 48.85) + (xy 92.373748 48.864143) (xy 92.194143 49.043748) (xy 92.18 49.029605) (xy 91.39404 49.815565) (xy 91.46102 50.055656) + (xy 91.59676 50.119485) (xy 91.518273 50.151995) (xy 91.289465 50.30488) (xy 91.09488 50.499465) (xy 90.941995 50.728273) + (xy 90.836686 50.98251) (xy 90.783 51.252408) (xy 90.783 51.527592) (xy 90.836686 51.79749) (xy 90.941995 52.051727) + (xy 91.09488 52.280535) (xy 91.289465 52.47512) (xy 91.518273 52.628005) (xy 91.595515 52.66) (xy 91.518273 52.691995) + (xy 91.289465 52.84488) (xy 91.09488 53.039465) (xy 90.941995 53.268273) (xy 90.836686 53.52251) (xy 90.783 53.792408) + (xy 90.783 54.067592) (xy 90.836686 54.33749) (xy 90.941995 54.591727) (xy 91.09488 54.820535) (xy 91.289465 55.01512) + (xy 91.518273 55.168005) (xy 91.595515 55.2) (xy 91.518273 55.231995) (xy 91.289465 55.38488) (xy 91.09488 55.579465) + (xy 90.941995 55.808273) (xy 90.836686 56.06251) (xy 90.783 56.332408) (xy 90.783 56.607592) (xy 90.836686 56.87749) + (xy 90.941995 57.131727) (xy 91.09488 57.360535) (xy 91.289465 57.55512) (xy 91.518273 57.708005) (xy 91.595515 57.74) + (xy 91.518273 57.771995) (xy 91.289465 57.92488) (xy 91.09488 58.119465) (xy 90.941995 58.348273) (xy 90.836686 58.60251) + (xy 90.783 58.872408) (xy 90.783 59.147592) (xy 90.836686 59.41749) (xy 90.941995 59.671727) (xy 91.09488 59.900535) + (xy 91.289465 60.09512) (xy 91.518273 60.248005) (xy 91.595515 60.28) (xy 91.518273 60.311995) (xy 91.289465 60.46488) + (xy 91.09488 60.659465) (xy 90.941995 60.888273) (xy 90.836686 61.14251) (xy 90.783 61.412408) (xy 90.783 61.687592) + (xy 90.836686 61.95749) (xy 90.941995 62.211727) (xy 91.09488 62.440535) (xy 91.289465 62.63512) (xy 91.518273 62.788005) + (xy 91.595515 62.82) (xy 91.518273 62.851995) (xy 91.289465 63.00488) (xy 91.09488 63.199465) (xy 90.941995 63.428273) + (xy 90.836686 63.68251) (xy 90.783 63.952408) (xy 90.783 64.227592) (xy 90.836686 64.49749) (xy 90.941995 64.751727) + (xy 91.09488 64.980535) (xy 91.289465 65.17512) (xy 91.518273 65.328005) (xy 91.595515 65.36) (xy 91.518273 65.391995) + (xy 91.289465 65.54488) (xy 91.09488 65.739465) (xy 90.941995 65.968273) (xy 90.836686 66.22251) (xy 90.783 66.492408) + (xy 90.783 66.767592) (xy 90.836686 67.03749) (xy 90.941995 67.291727) (xy 91.09488 67.520535) (xy 91.289465 67.71512) + (xy 91.518273 67.868005) (xy 91.595515 67.9) (xy 91.518273 67.931995) (xy 91.289465 68.08488) (xy 91.09488 68.279465) + (xy 90.941995 68.508273) (xy 90.836686 68.76251) (xy 90.783 69.032408) (xy 90.783 69.307592) (xy 90.836686 69.57749) + (xy 90.941995 69.831727) (xy 91.09488 70.060535) (xy 91.289465 70.25512) (xy 91.518273 70.408005) (xy 91.77251 70.513314) + (xy 92.042408 70.567) (xy 92.094478 70.567) (xy 92.135501 70.773235) (xy 92.24081 71.027472) (xy 92.393695 71.25628) + (xy 92.58828 71.450865) (xy 92.817088 71.60375) (xy 93.071325 71.709059) (xy 93.341223 71.762745) (xy 93.616407 71.762745) + (xy 93.886305 71.709059) (xy 94.140542 71.60375) (xy 94.36935 71.450865) (xy 94.458056 71.362159) (xy 94.55644 71.402911) + (xy 94.71776 71.435) (xy 94.88224 71.435) (xy 95.04356 71.402911) (xy 95.195521 71.339967) (xy 95.332281 71.248587) + (xy 95.448587 71.132281) (xy 95.539967 70.995521) (xy 95.602911 70.84356) (xy 95.635 70.68224) (xy 95.635 70.51776) + (xy 95.634933 70.517422) (xy 95.677315 70.569065) (xy 95.774006 70.648417) (xy 95.88432 70.707382) (xy 95.94 70.724272) + (xy 95.940001 73.504029) (xy 95.849943 73.564203) (xy 95.664203 73.749943) (xy 95.518268 73.968351) (xy 95.417746 74.211032) + (xy 95.3665 74.468662) (xy 95.3665 74.731338) (xy 95.417746 74.988968) (xy 95.518268 75.231649) (xy 95.664203 75.450057) + (xy 95.849943 75.635797) (xy 96.068351 75.781732) (xy 96.311032 75.882254) (xy 96.568662 75.9335) (xy 96.831338 75.9335) + (xy 97.088968 75.882254) (xy 97.331649 75.781732) (xy 97.4565 75.69831) (xy 97.4565 81.367451) (xy 97.452823 81.404784) + (xy 97.4565 81.442117) (xy 97.466023 81.538799) (xy 97.467497 81.553769) (xy 97.510953 81.69703) (xy 97.581525 81.82906) + (xy 97.648542 81.910719) (xy 97.676499 81.944785) (xy 97.705497 81.968583) (xy 97.804168 82.067254) (xy 97.680967 82.079388) + (xy 96.626606 81.025027) (xy 96.681004 80.943614) (xy 96.781526 80.700933) (xy 96.832772 80.443303) (xy 96.832772 80.180627) + (xy 96.781526 79.922997) (xy 96.681004 79.680316) (xy 96.535069 79.461908) (xy 96.384272 79.311111) (xy 96.384272 79.062819) + (xy 96.535069 78.912022) (xy 96.681004 78.693614) (xy 96.781526 78.450933) (xy 96.832772 78.193303) (xy 96.832772 77.930627) + (xy 96.781526 77.672997) (xy 96.681004 77.430316) (xy 96.535069 77.211908) (xy 96.349329 77.026168) (xy 96.130921 76.880233) + (xy 95.88824 76.779711) (xy 95.63061 76.728465) (xy 95.367934 76.728465) (xy 95.110304 76.779711) (xy 94.867623 76.880233) + (xy 94.649215 77.026168) (xy 94.463475 77.211908) (xy 94.31754 77.430316) (xy 94.217018 77.672997) (xy 94.165772 77.930627) + (xy 94.165772 78.193303) (xy 94.217018 78.450933) (xy 94.31754 78.693614) (xy 94.463475 78.912022) (xy 94.614272 79.062819) + (xy 94.614272 79.311111) (xy 94.463475 79.461908) (xy 94.31754 79.680316) (xy 94.217018 79.922997) (xy 94.165772 80.180627) + (xy 94.165772 80.443303) (xy 94.217018 80.700933) (xy 94.31754 80.943614) (xy 94.463475 81.162022) (xy 94.628323 81.32687) + (xy 94.677684 81.489585) (xy 94.759862 81.643331) (xy 94.84274 81.744318) (xy 94.842743 81.744321) (xy 94.870456 81.778089) + (xy 94.904223 81.805801) (xy 95.28482 82.186398) (xy 95.114269 82.11831) (xy 94.827 82.065) (xy 94.427 82.065) + (xy 94.427 83.423) (xy 96.020155 83.423) (xy 96.141476 83.19311) (xy 96.120563 83.099047) (xy 96.062698 82.964276) + (xy 96.429388 83.330967) (xy 96.407815 83.55) (xy 96.436487 83.841111) (xy 96.521401 84.121034) (xy 96.659294 84.379014) + (xy 96.701935 84.430972) (xy 96.621637 84.415) (xy 96.378363 84.415) (xy 96.139764 84.46246) (xy 95.915008 84.555557) + (xy 95.712733 84.690713) (xy 95.540713 84.862733) (xy 95.405557 85.065008) (xy 95.31246 85.289764) (xy 95.265 85.528363) + (xy 95.265 85.771637) (xy 95.31246 86.010236) (xy 95.405557 86.234992) (xy 95.540713 86.437267) (xy 95.628446 86.525) + (xy 95.540713 86.612733) (xy 95.405557 86.815008) (xy 95.31246 87.039764) (xy 95.265 87.278363) (xy 95.265 87.521637) + (xy 95.31246 87.760236) (xy 95.405557 87.984992) (xy 95.540713 88.187267) (xy 95.712733 88.359287) (xy 95.915008 88.494443) + (xy 96.139764 88.58754) (xy 96.378363 88.635) (xy 96.621637 88.635) (xy 96.701935 88.619028) (xy 96.659294 88.670986) + (xy 96.521401 88.928966) (xy 96.436487 89.208889) (xy 96.407815 89.5) (xy 96.436487 89.791111) (xy 96.521401 90.071034) + (xy 96.659294 90.329014) (xy 96.844866 90.555134) (xy 97.070986 90.740706) (xy 97.328966 90.878599) (xy 97.608889 90.963513) + (xy 97.82705 90.985) (xy 98.77295 90.985) (xy 98.991111 90.963513) (xy 99.271034 90.878599) (xy 99.529014 90.740706) + (xy 99.755134 90.555134) (xy 99.940706 90.329014) (xy 100.078599 90.071034) (xy 100.163513 89.791111) (xy 100.192185 89.5) + (xy 100.166085 89.235) (xy 100.27295 89.235) (xy 100.491111 89.213513) (xy 100.615011 89.175928) (xy 100.615011 92.810187) + (xy 92.991376 100.433823) (xy 92.976912 100.427832) (xy 92.661033 100.365) (xy 92.338967 100.365) (xy 92.023088 100.427832) + (xy 91.725537 100.551082) (xy 91.457748 100.730013) (xy 91.230013 100.957748) (xy 91.051082 101.225537) (xy 90.927832 101.523088) + (xy 90.865 101.838967) (xy 90.865 102.161033) (xy 90.927832 102.476912) (xy 91.051082 102.774463) (xy 91.230013 103.042252) + (xy 91.457748 103.269987) (xy 91.554935 103.334925) (xy 91.544192 103.364587) (xy 92.5 104.320395) (xy 92.514143 104.306253) + (xy 92.693748 104.485858) (xy 92.679605 104.5) (xy 92.693748 104.514143) (xy 92.514143 104.693748) (xy 92.5 104.679605) + (xy 91.544192 105.635413) (xy 91.554935 105.665075) (xy 91.457748 105.730013) (xy 91.230013 105.957748) (xy 91.051082 106.225537) + (xy 90.927832 106.523088) (xy 90.865 106.838967) (xy 90.865 107.161033) (xy 90.927832 107.476912) (xy 91.051082 107.774463) + (xy 91.230013 108.042252) (xy 91.457748 108.269987) (xy 91.725537 108.448918) (xy 92.023088 108.572168) (xy 92.338967 108.635) + (xy 92.661033 108.635) (xy 92.976912 108.572168) (xy 93.274463 108.448918) (xy 93.542252 108.269987) (xy 93.769987 108.042252) + (xy 93.948918 107.774463) (xy 94.072168 107.476912) (xy 94.135 107.161033) (xy 94.135 106.838967) (xy 94.072168 106.523088) + (xy 94.066177 106.508624) (xy 94.335998 106.238803) (xy 94.365002 106.215) (xy 94.459975 106.099275) (xy 94.530547 105.967246) + (xy 94.574004 105.823985) (xy 94.585001 105.712332) (xy 94.585001 105.712323) (xy 94.588677 105.675) (xy 94.585001 105.637677) + (xy 94.585001 101.62621) (xy 97.761928 98.449283) (xy 97.761928 99.9) (xy 97.774188 100.024482) (xy 97.810498 100.14418) + (xy 97.869463 100.254494) (xy 97.948815 100.351185) (xy 98.045506 100.430537) (xy 98.15582 100.489502) (xy 98.275518 100.525812) + (xy 98.4 100.538072) (xy 101.6 100.538072) (xy 101.724482 100.525812) (xy 101.84418 100.489502) (xy 101.954494 100.430537) + (xy 102.051185 100.351185) (xy 102.130537 100.254494) (xy 102.189502 100.14418) (xy 102.225812 100.024482) (xy 102.238072 99.9) + (xy 102.238072 97.9) (xy 102.225812 97.775518) (xy 102.189502 97.65582) (xy 102.130537 97.545506) (xy 102.051185 97.448815) + (xy 101.954494 97.369463) (xy 101.84418 97.310498) (xy 101.724482 97.274188) (xy 101.6 97.261928) (xy 98.949283 97.261928) + (xy 99.686211 96.525) (xy 103.936928 96.525) (xy 103.936928 97.475) (xy 103.949188 97.599482) (xy 103.985498 97.71918) + (xy 104.044463 97.829494) (xy 104.123815 97.926185) (xy 104.220506 98.005537) (xy 104.33082 98.064502) (xy 104.450518 98.100812) + (xy 104.575 98.113072) (xy 105.875 98.113072) (xy 105.999482 98.100812) (xy 106.11918 98.064502) (xy 106.229494 98.005537) + (xy 106.326185 97.926185) (xy 106.405537 97.829494) (xy 106.410964 97.819341) (xy 106.49356 97.802911) (xy 106.645521 97.739967) + (xy 106.782281 97.648587) (xy 106.898587 97.532281) (xy 106.989967 97.395521) (xy 107.052911 97.24356) (xy 107.085 97.08224) + (xy 107.085 96.91776) (xy 107.052911 96.75644) (xy 106.989967 96.604479) (xy 106.898587 96.467719) (xy 106.782281 96.351413) + (xy 106.645521 96.260033) (xy 106.49356 96.197089) (xy 106.410964 96.180659) (xy 106.405537 96.170506) (xy 106.326185 96.073815) + (xy 106.292053 96.045804) (xy 106.740475 96.135) (xy 107.259525 96.135) (xy 107.707947 96.045804) (xy 107.673815 96.073815) + (xy 107.594463 96.170506) (xy 107.535498 96.28082) (xy 107.499188 96.400518) (xy 107.486928 96.525) (xy 107.486928 96.988271) + (xy 107.483077 96.992121) (xy 107.379479 97.035033) (xy 107.242719 97.126413) (xy 107.126413 97.242719) (xy 107.035033 97.379479) + (xy 106.992122 97.483077) (xy 106.489002 97.986197) (xy 106.459999 98.009999) (xy 106.42023 98.058458) (xy 106.365026 98.125724) + (xy 106.308088 98.232247) (xy 106.294454 98.257754) (xy 106.250997 98.401015) (xy 106.24 98.512668) (xy 106.24 98.512678) + (xy 106.236324 98.55) (xy 106.24 98.587323) (xy 106.240001 100.545091) (xy 106.225537 100.551082) (xy 105.957748 100.730013) + (xy 105.730013 100.957748) (xy 105.551082 101.225537) (xy 105.427832 101.523088) (xy 105.365 101.838967) (xy 105.365 102.161033) + (xy 105.427832 102.476912) (xy 105.551082 102.774463) (xy 105.730013 103.042252) (xy 105.957748 103.269987) (xy 106.225537 103.448918) + (xy 106.523088 103.572168) (xy 106.838967 103.635) (xy 107.161033 103.635) (xy 107.476912 103.572168) (xy 107.774463 103.448918) + (xy 108.042252 103.269987) (xy 108.269987 103.042252) (xy 108.448918 102.774463) (xy 108.572168 102.476912) (xy 108.635 102.161033) + (xy 108.635 101.838967) (xy 108.572168 101.523088) (xy 108.448918 101.225537) (xy 108.269987 100.957748) (xy 108.042252 100.730013) + (xy 107.774463 100.551082) (xy 107.76 100.545091) (xy 107.76 98.864801) (xy 108.066923 98.557878) (xy 108.170521 98.514967) + (xy 108.307281 98.423587) (xy 108.423587 98.307281) (xy 108.514967 98.170521) (xy 108.538763 98.113072) (xy 109.425 98.113072) + (xy 109.549482 98.100812) (xy 109.66918 98.064502) (xy 109.779494 98.005537) (xy 109.876185 97.926185) (xy 109.955537 97.829494) + (xy 110.014502 97.71918) (xy 110.050812 97.599482) (xy 110.063072 97.475) (xy 110.063072 96.525) (xy 110.050812 96.400518) + (xy 110.014502 96.28082) (xy 109.955537 96.170506) (xy 109.876185 96.073815) (xy 109.779494 95.994463) (xy 109.66918 95.935498) + (xy 109.549482 95.899188) (xy 109.425 95.886928) (xy 108.125 95.886928) (xy 108.122421 95.887182) (xy 108.248141 95.835107) + (xy 108.679715 95.546738) (xy 109.046738 95.179715) (xy 109.335107 94.748141) (xy 109.533739 94.268601) (xy 109.635 93.759525) + (xy 109.635 93.240475) (xy 109.533739 92.731399) (xy 109.335107 92.251859) (xy 109.046738 91.820285) (xy 108.679715 91.453262) + (xy 108.248141 91.164893) (xy 107.768601 90.966261) (xy 107.259525 90.865) (xy 106.740475 90.865) (xy 106.231399 90.966261) + (xy 105.751859 91.164893) (xy 105.320285 91.453262) (xy 104.953262 91.820285) (xy 104.664893 92.251859) (xy 104.466261 92.731399) + (xy 104.365 93.240475) (xy 104.365 93.759525) (xy 104.466261 94.268601) (xy 104.664893 94.748141) (xy 104.953262 95.179715) + (xy 105.320285 95.546738) (xy 105.751859 95.835107) (xy 105.877579 95.887182) (xy 105.875 95.886928) (xy 104.575 95.886928) + (xy 104.450518 95.899188) (xy 104.33082 95.935498) (xy 104.220506 95.994463) (xy 104.123815 96.073815) (xy 104.044463 96.170506) + (xy 103.985498 96.28082) (xy 103.949188 96.400518) (xy 103.936928 96.525) (xy 99.686211 96.525) (xy 105.810993 90.400219) + (xy 105.839991 90.376421) (xy 105.883871 90.322953) (xy 105.934964 90.260697) (xy 106.005536 90.128667) (xy 106.019996 90.080997) + (xy 106.048993 89.985406) (xy 106.05999 89.873753) (xy 106.05999 89.873744) (xy 106.063666 89.836421) (xy 106.05999 89.799098) + (xy 106.05999 88.171683) (xy 106.22651 88.222197) (xy 106.36362 88.235701) (xy 106.40151 88.247195) (xy 106.436846 88.250675) + (xy 106.498815 88.326185) (xy 106.595506 88.405537) (xy 106.70582 88.464502) (xy 106.825518 88.500812) (xy 106.95 88.513072) + (xy 108.95 88.513072) (xy 109.074482 88.500812) (xy 109.19418 88.464502) (xy 109.304494 88.405537) (xy 109.401185 88.326185) + (xy 109.476015 88.235004) (xy 109.48224 88.235004) (xy 109.64356 88.202915) (xy 109.795521 88.139971) (xy 109.932281 88.048591) + (xy 110.048587 87.932285) (xy 110.139967 87.795525) (xy 110.202911 87.643564) (xy 110.235 87.482244) (xy 110.235 87.317764) + (xy 110.202911 87.156444) (xy 110.16 87.052847) (xy 110.16 86.385) (xy 112.127843 86.385) (xy 112.23144 86.427911) + (xy 112.39276 86.46) (xy 112.55724 86.46) (xy 112.71856 86.427911) (xy 112.870521 86.364967) (xy 113.007281 86.273587) + (xy 113.123587 86.157281) (xy 113.214967 86.020521) (xy 113.277911 85.86856) (xy 113.31 85.70724) (xy 113.31 85.54276) + (xy 113.277911 85.38144) (xy 113.214967 85.229479) (xy 113.123587 85.092719) (xy 113.007281 84.976413) (xy 112.870521 84.885033) + (xy 112.71856 84.822089) (xy 112.55724 84.79) (xy 112.39276 84.79) (xy 112.23144 84.822089) (xy 112.127843 84.865) + (xy 111.968895 84.865) (xy 112.051614 84.782281) (xy 112.142994 84.645521) (xy 112.205938 84.49356) (xy 112.238027 84.33224) + (xy 112.238027 84.16776) (xy 112.205938 84.00644) (xy 112.142994 83.854479) (xy 112.051614 83.717719) (xy 111.935308 83.601413) + (xy 111.798548 83.510033) (xy 111.646587 83.447089) (xy 111.485267 83.415) (xy 111.320787 83.415) (xy 111.159467 83.447089) + (xy 111.05587 83.49) (xy 108.897157 83.49) (xy 108.79356 83.447089) (xy 108.63224 83.415) (xy 108.46776 83.415) + (xy 108.30644 83.447089) (xy 108.154479 83.510033) (xy 108.017719 83.601413) (xy 107.901413 83.717719) (xy 107.810033 83.854479) + (xy 107.747089 84.00644) (xy 107.715 84.16776) (xy 107.715 84.33224) (xy 107.74577 84.486928) (xy 107.285 84.486928) + (xy 107.285 83.390819) (xy 107.36441 83.294058) (xy 107.446588 83.140313) (xy 107.497194 82.97349) (xy 107.51428 82.8) + (xy 107.497194 82.62651) (xy 107.458839 82.500072) (xy 108.10898 82.500072) (xy 108.171688 82.53359) (xy 108.338511 82.584196) + (xy 108.468524 82.597001) (xy 108.468534 82.597001) (xy 108.512 82.601282) (xy 108.555466 82.597001) (xy 114.295423 82.597001) + (xy 114.713355 83.014933) (xy 114.604473 83.060033) (xy 114.467713 83.151413) (xy 114.351407 83.267719) (xy 114.260027 83.404479) + (xy 114.197083 83.55644) (xy 114.164994 83.71776) (xy 114.164994 83.88224) (xy 114.197083 84.04356) (xy 114.239995 84.147159) + (xy 114.239994 84.962671) (xy 114.236318 84.999994) (xy 114.239994 85.037316) (xy 114.239994 85.037326) (xy 114.250991 85.148979) + (xy 114.281792 85.250518) (xy 114.294448 85.29224) (xy 114.36502 85.42427) (xy 114.404865 85.47282) (xy 114.459993 85.539995) + (xy 114.488997 85.563798) (xy 115.440198 86.515) (xy 115.263891 86.515) (xy 114.957673 86.575911) (xy 114.669221 86.695391) + (xy 114.409621 86.86885) (xy 114.18885 87.089621) (xy 114.015391 87.349221) (xy 113.895911 87.637673) (xy 113.835 87.943891) + (xy 113.835 88.256109) (xy 113.895911 88.562327) (xy 114.015391 88.850779) (xy 114.18885 89.110379) (xy 114.409621 89.33115) + (xy 114.669221 89.504609) (xy 114.835016 89.573283) (xy 114.797988 89.628699) (xy 114.637047 90.017245) (xy 114.555 90.429722) + (xy 114.555 90.85028) (xy 114.637047 91.262757) (xy 114.769252 91.581928) (xy 114.23673 91.581928) (xy 112.968804 90.314003) + (xy 112.945001 90.284999) (xy 112.829276 90.190026) (xy 112.697247 90.119454) (xy 112.553986 90.075997) (xy 112.442333 90.065) + (xy 112.442322 90.065) (xy 112.405 90.061324) (xy 112.367678 90.065) (xy 111.585 90.065) (xy 111.585 89.957972) + (xy 111.61001 89.83224) (xy 111.61001 89.66776) (xy 111.577921 89.50644) (xy 111.514977 89.354479) (xy 111.423597 89.217719) + (xy 111.307291 89.101413) (xy 111.170531 89.010033) (xy 111.01857 88.947089) (xy 110.85725 88.915) (xy 110.69277 88.915) + (xy 110.53145 88.947089) (xy 110.379489 89.010033) (xy 110.242729 89.101413) (xy 110.126423 89.217719) (xy 110.035043 89.354479) + (xy 109.972099 89.50644) (xy 109.94001 89.66776) (xy 109.94001 89.83224) (xy 109.972099 89.99356) (xy 110.035043 90.145521) + (xy 110.065001 90.190356) (xy 110.065 90.787667) (xy 110.061323 90.825) (xy 110.065 90.862332) (xy 110.065001 105.360197) + (xy 109.185199 106.24) (xy 108.454909 106.24) (xy 108.448918 106.225537) (xy 108.269987 105.957748) (xy 108.042252 105.730013) + (xy 107.774463 105.551082) (xy 107.476912 105.427832) (xy 107.161033 105.365) (xy 106.838967 105.365) (xy 106.523088 105.427832) + (xy 106.225537 105.551082) (xy 105.957748 105.730013) (xy 105.730013 105.957748) (xy 105.551082 106.225537) (xy 105.427832 106.523088) + (xy 105.365 106.838967) (xy 105.365 107.161033) (xy 105.427832 107.476912) (xy 105.551082 107.774463) (xy 105.730013 108.042252) + (xy 105.957748 108.269987) (xy 106.225537 108.448918) (xy 106.523088 108.572168) (xy 106.838967 108.635) (xy 107.161033 108.635) + (xy 107.476912 108.572168) (xy 107.774463 108.448918) (xy 108.042252 108.269987) (xy 108.269987 108.042252) (xy 108.448918 107.774463) + (xy 108.454909 107.76) (xy 109.462678 107.76) (xy 109.5 107.763676) (xy 109.537322 107.76) (xy 109.537333 107.76) + (xy 109.648986 107.749003) (xy 109.792247 107.705546) (xy 109.924276 107.634974) (xy 110.040001 107.540001) (xy 110.063804 107.510997) + (xy 110.065 107.509801) (xy 110.065001 110.287668) (xy 110.061324 110.325) (xy 110.065001 110.362333) (xy 110.075998 110.473986) + (xy 110.083006 110.497089) (xy 110.119454 110.617246) (xy 110.190026 110.749276) (xy 110.24 110.810169) (xy 110.240001 111.462668) + (xy 110.236324 111.5) (xy 110.240001 111.537333) (xy 110.250998 111.648986) (xy 110.254444 111.660345) (xy 110.294454 111.792246) + (xy 110.365026 111.924276) (xy 110.432361 112.006323) (xy 110.46 112.040001) (xy 110.488998 112.063799) (xy 110.967122 112.541923) + (xy 111.010033 112.645521) (xy 111.101413 112.782281) (xy 111.217719 112.898587) (xy 111.354479 112.989967) (xy 111.50644 113.052911) + (xy 111.66776 113.085) (xy 111.83224 113.085) (xy 111.99356 113.052911) (xy 112.04 113.033675) (xy 112.04 114.212679) + (xy 112.036324 114.250002) (xy 112.04 114.287324) (xy 112.04 114.287334) (xy 112.050997 114.398987) (xy 112.087547 114.519479) + (xy 112.094454 114.542248) (xy 112.165026 114.674278) (xy 112.194342 114.709999) (xy 112.259999 114.790003) (xy 112.289002 114.813805) + (xy 112.961204 115.486009) (xy 112.984998 115.515002) (xy 113.013991 115.538796) (xy 113.013995 115.5388) (xy 113.075059 115.588913) + (xy 113.100723 115.609975) (xy 113.232752 115.680547) (xy 113.376013 115.724004) (xy 113.487666 115.735001) (xy 113.487675 115.735001) + (xy 113.524998 115.738677) (xy 113.562321 115.735001) (xy 126.487677 115.735001) (xy 126.524999 115.738677) (xy 126.562321 115.735001) + (xy 126.562332 115.735001) (xy 126.673985 115.724004) (xy 126.817246 115.680547) (xy 126.949275 115.609975) (xy 127.065 115.515002) + (xy 127.088803 115.485999) (xy 128.011003 114.563799) (xy 128.040001 114.540001) (xy 128.130241 114.430043) (xy 129.356728 115.656531) + (xy 129.357689 115.66136) (xy 129.390926 115.741602) (xy 111.938924 115.741602) (xy 111.901601 115.737926) (xy 111.864278 115.741602) + (xy 111.864269 115.741602) (xy 111.752616 115.752599) (xy 111.609355 115.796056) (xy 111.477326 115.866628) (xy 111.361601 115.961601) + (xy 111.337803 115.990599) (xy 109.088403 118.24) (xy 108.037322 118.24) (xy 107.999999 118.236324) (xy 107.962676 118.24) + (xy 107.962667 118.24) (xy 107.851014 118.250997) (xy 107.709118 118.29404) (xy 107.707753 118.294454) (xy 107.575723 118.365026) + (xy 107.499176 118.427847) (xy 107.459999 118.459999) (xy 107.436201 118.488997) (xy 105.740026 120.185172) (xy 105.870288 119.870692) + (xy 105.985 119.293997) (xy 105.985 118.706003) (xy 105.870288 118.129308) (xy 105.645273 117.586072) (xy 105.318601 117.097174) + (xy 104.902826 116.681399) (xy 104.413928 116.354727) (xy 103.870692 116.129712) (xy 103.293997 116.015) (xy 102.706003 116.015) + (xy 102.129308 116.129712) (xy 101.586072 116.354727) (xy 101.097174 116.681399) (xy 100.681399 117.097174) (xy 100.354727 117.586072) + (xy 100.129712 118.129308) (xy 100.015 118.706003) (xy 100.015 119.293997) (xy 100.129712 119.870692) (xy 100.354727 120.413928) + (xy 100.681399 120.902826) (xy 100.843372 121.064799) (xy 98.662127 121.064799) (xy 98.624804 121.061123) (xy 98.587481 121.064799) + (xy 98.587472 121.064799) (xy 98.475819 121.075796) (xy 98.332558 121.119253) (xy 98.200529 121.189825) (xy 98.084804 121.284798) + (xy 98.061006 121.313797) (xy 97.407504 121.967299) (xy 97.407499 121.967303) (xy 90.226377 129.148426) (xy 90.196703 129.107016) + (xy 90.105409 129.021509) (xy 89.999187 128.955457) (xy 89.88212 128.911396) (xy 89.758707 128.89102) (xy 89.63369 128.895113) + (xy 89.511873 128.923516) (xy 89.397939 128.97514) (xy 87.665889 129.97514) (xy 87.564215 130.047998) (xy 87.478708 130.139292) + (xy 87.412656 130.245514) (xy 87.368595 130.362581) (xy 87.348219 130.485994) (xy 87.352312 130.611011) (xy 87.380715 130.732828) + (xy 87.432338 130.846762) (xy 87.833394 131.54141) (xy 87.761998 131.612806) (xy 87.733 131.636604) (xy 87.709202 131.665602) + (xy 87.709201 131.665603) (xy 87.638026 131.752329) (xy 87.567454 131.884359) (xy 87.543131 131.964546) (xy 87.523998 132.027619) + (xy 87.519847 132.06976) (xy 87.509324 132.176605) (xy 87.513001 132.213937) (xy 87.513 132.937842) (xy 87.470089 133.04144) + (xy 87.438 133.20276) (xy 87.438 133.36724) (xy 87.470089 133.52856) (xy 87.533033 133.680521) (xy 87.624413 133.817281) + (xy 87.740719 133.933587) (xy 87.877479 134.024967) (xy 88.02944 134.087911) (xy 88.19076 134.12) (xy 88.35524 134.12) + (xy 88.51656 134.087911) (xy 88.668521 134.024967) (xy 88.805281 133.933587) (xy 88.905591 133.833277) (xy 88.905591 133.950574) + (xy 88.987638 134.363051) (xy 89.148579 134.751597) (xy 89.382228 135.101278) (xy 89.679608 135.398658) (xy 90.029289 135.632307) + (xy 90.417835 135.793248) (xy 90.830312 135.875295) (xy 91.25087 135.875295) (xy 91.663347 135.793248) (xy 92.051893 135.632307) + (xy 92.401574 135.398658) (xy 92.698954 135.101278) (xy 92.932603 134.751597) (xy 93.093544 134.363051) (xy 93.175591 133.950574) + (xy 93.175591 133.530016) (xy 93.157187 133.437493) (xy 93.228051 133.423397) (xy 93.616597 133.262456) (xy 93.966278 133.028807) + (xy 94.066086 132.928999) (xy 94.025 133.135551) (xy 94.025 133.664449) (xy 94.128183 134.183186) (xy 94.330583 134.671825) + (xy 94.624424 135.111588) (xy 94.998412 135.485576) (xy 95.438175 135.779417) (xy 95.780957 135.921401) (xy 95.403993 136.077545) + (xy 95.054312 136.311194) (xy 94.907159 136.458347) (xy 94.591893 136.247693) (xy 94.203347 136.086752) (xy 93.79087 136.004705) + (xy 93.370312 136.004705) (xy 92.957835 136.086752) (xy 92.569289 136.247693) (xy 92.219608 136.481342) (xy 91.922228 136.778722) + (xy 91.688579 137.128403) (xy 91.527638 137.516949) (xy 91.445591 137.929426) (xy 91.445591 138.349984) (xy 91.527638 138.762461) + (xy 91.688579 139.151007) (xy 91.922228 139.500688) (xy 92.219608 139.798068) (xy 92.569289 140.031717) (xy 92.957835 140.192658) + (xy 93.370312 140.274705) (xy 93.79087 140.274705) (xy 94.203347 140.192658) (xy 94.591893 140.031717) (xy 94.941574 139.798068) + (xy 95.088727 139.650915) (xy 95.403993 139.861569) (xy 95.792539 140.02251) (xy 95.933558 140.050561) (xy 95.918299 140.091104) + (xy 95.897923 140.214517) (xy 95.902016 140.339534) (xy 95.930419 140.461351) (xy 95.982042 140.575285) (xy 97.132042 142.567143) + (xy 97.204901 142.668817) (xy 97.296195 142.754324) (xy 97.402417 142.820376) (xy 97.519484 142.864437) (xy 97.642897 142.884813) + (xy 97.767914 142.88072) (xy 97.889731 142.852317) (xy 98.003665 142.800693) (xy 99.735715 141.800693) (xy 99.837389 141.727835) + (xy 99.922896 141.636541) (xy 99.988948 141.530319) (xy 100.033009 141.413252) (xy 100.053385 141.289839) (xy 100.049292 141.164822) + (xy 100.020889 141.043005) (xy 99.969266 140.929071) (xy 99.494905 140.107454) (xy 99.522 139.97124) (xy 99.522 139.80676) + (xy 99.489911 139.64544) (xy 99.426967 139.493479) (xy 99.354089 139.384409) (xy 99.406109 139.384409) (xy 99.712327 139.323498) + (xy 100.000779 139.204018) (xy 100.260379 139.030559) (xy 100.48115 138.809788) (xy 100.654609 138.550188) (xy 100.774089 138.261736) + (xy 100.835 137.955518) (xy 100.835 137.6433) (xy 100.774089 137.337082) (xy 100.654609 137.04863) (xy 100.48115 136.78903) + (xy 100.260379 136.568259) (xy 100.257868 136.566581) (xy 100.113475 136.350482) (xy 99.906632 136.143639) (xy 99.663411 135.981124) + (xy 99.393158 135.869182) (xy 99.10626 135.812114) (xy 98.81374 135.812114) (xy 98.526842 135.869182) (xy 98.256589 135.981124) + (xy 98.013368 136.143639) (xy 97.811046 136.345962) (xy 97.776278 136.311194) (xy 97.426597 136.077545) (xy 97.292069 136.021822) + (xy 97.493186 135.981817) (xy 97.981825 135.779417) (xy 98.421588 135.485576) (xy 98.795576 135.111588) (xy 99.089417 134.671825) + (xy 99.291817 134.183186) (xy 99.395 133.664449) (xy 99.395 133.135551) (xy 99.372733 133.023608) (xy 99.736974 133.654492) + (xy 99.751434 133.686405) (xy 99.771841 133.714883) (xy 99.771846 133.714892) (xy 99.832896 133.800088) (xy 99.934974 133.895694) + (xy 100.053741 133.969548) (xy 100.184635 134.018813) (xy 100.322625 134.041595) (xy 100.322626 134.041595) (xy 100.462407 134.037019) + (xy 100.598612 134.005261) (xy 100.694081 133.962004) (xy 100.694082 133.962004) (xy 100.726003 133.94754) (xy 100.754489 133.927127) + (xy 100.969143 133.803197) (xy 101.329768 134.427817) (xy 101.402626 134.529491) (xy 101.49392 134.614997) (xy 101.600142 134.68105) + (xy 101.717209 134.725111) (xy 101.840622 134.745487) (xy 101.869732 134.744534) (xy 102.636205 135.511008) (xy 102.659999 135.540001) + (xy 102.688992 135.563795) (xy 102.688996 135.563799) (xy 102.759685 135.621811) (xy 102.775724 135.634974) (xy 102.907753 135.705546) + (xy 103.051014 135.749003) (xy 103.162667 135.76) (xy 103.162676 135.76) (xy 103.199999 135.763676) (xy 103.237322 135.76) + (xy 103.975864 135.76) (xy 104.013186 135.763676) (xy 104.050508 135.76) (xy 104.050519 135.76) (xy 104.162172 135.749003) + (xy 104.305433 135.705546) (xy 104.437462 135.634974) (xy 104.553187 135.540001) (xy 104.57699 135.510998) (xy 105.295532 134.792456) + (xy 105.376094 134.776431) (xy 105.528055 134.713487) (xy 105.664815 134.622107) (xy 105.781121 134.505801) (xy 105.872501 134.369041) + (xy 105.935445 134.21708) (xy 105.954744 134.120057) (xy 107.54 132.534801) (xy 107.54 132.981451) (xy 107.536324 133.018774) + (xy 107.54 133.056096) (xy 107.54 133.056106) (xy 107.550997 133.167759) (xy 107.588409 133.291091) (xy 107.594454 133.31102) + (xy 107.665026 133.44305) (xy 107.686954 133.469769) (xy 107.759999 133.558775) (xy 107.789003 133.582578) (xy 111.126814 136.92039) + (xy 111.150612 136.949388) (xy 111.17961 136.973186) (xy 111.266336 137.044361) (xy 111.398366 137.114933) (xy 111.541627 137.15839) + (xy 111.65328 137.169387) (xy 111.65329 137.169387) (xy 111.690613 137.173063) (xy 111.727936 137.169387) (xy 122.953291 137.169387) + (xy 122.990613 137.173063) (xy 123.027935 137.169387) (xy 123.027946 137.169387) (xy 123.139599 137.15839) (xy 123.28286 137.114933) + (xy 123.414889 137.044361) (xy 123.530614 136.949388) (xy 123.554417 136.920384) (xy 127.214802 133.26) (xy 137.704478 133.26) + (xy 137.7418 133.263676) (xy 137.779122 133.26) (xy 137.779133 133.26) (xy 137.890786 133.249003) (xy 138.034047 133.205546) + (xy 138.166076 133.134974) (xy 138.281801 133.040001) (xy 138.305604 133.010997) (xy 140.307866 131.008736) (xy 140.305089 131.01544) + (xy 140.273 131.17676) (xy 140.273 131.34124) (xy 140.305089 131.50256) (xy 140.368033 131.654521) (xy 140.459413 131.791281) + (xy 140.575719 131.907587) (xy 140.712479 131.998967) (xy 140.86444 132.061911) (xy 141.02576 132.094) (xy 141.19024 132.094) + (xy 141.35156 132.061911) (xy 141.455157 132.019) (xy 142.504792 132.019) (xy 142.514889 132.06976) (xy 142.577833 132.221721) + (xy 142.669213 132.358481) (xy 142.785519 132.474787) (xy 142.922279 132.566167) (xy 143.07424 132.629111) (xy 143.23556 132.6612) + (xy 143.40004 132.6612) (xy 143.56136 132.629111) (xy 143.713321 132.566167) (xy 143.850081 132.474787) (xy 143.966387 132.358481) + (xy 144.057767 132.221721) (xy 144.100679 132.118122) (xy 146.629812 129.58899) (xy 146.983584 129.58899) (xy 146.985289 129.59756) + (xy 147.048233 129.749521) (xy 147.139613 129.886281) (xy 147.255919 130.002587) (xy 147.392679 130.093967) (xy 147.54464 130.156911) + (xy 147.70596 130.189) (xy 147.87044 130.189) (xy 148.03176 130.156911) (xy 148.135357 130.114) (xy 162.81368 130.114) + (xy 162.851002 130.117676) (xy 162.888324 130.114) (xy 162.888335 130.114) (xy 162.999988 130.103003) (xy 163.143249 130.059546) + (xy 163.275278 129.988974) (xy 163.391003 129.894001) (xy 163.414806 129.864997) (xy 166.454221 126.825583) (xy 166.539813 126.953681) + (xy 166.656119 127.069987) (xy 166.792879 127.161367) (xy 166.94484 127.224311) (xy 167.10616 127.2564) (xy 167.27064 127.2564) + (xy 167.43196 127.224311) (xy 167.583921 127.161367) (xy 167.720681 127.069987) (xy 167.836987 126.953681) (xy 167.928367 126.816921) + (xy 167.971279 126.713322) (xy 170.935 123.749602) (xy 170.935 123.956109) (xy 170.995911 124.262327) (xy 171.115391 124.550779) + (xy 171.28885 124.810379) (xy 171.509621 125.03115) (xy 171.769221 125.204609) (xy 171.935016 125.273283) (xy 171.897988 125.328699) + (xy 171.737047 125.717245) (xy 171.655 126.129722) (xy 171.655 126.55028) (xy 171.737047 126.962757) (xy 171.869252 127.281928) + (xy 170.75 127.281928) (xy 170.625518 127.294188) (xy 170.50582 127.330498) (xy 170.395506 127.389463) (xy 170.298815 127.468815) + (xy 170.219463 127.565506) (xy 170.160498 127.67582) (xy 170.124188 127.795518) (xy 170.111928 127.92) (xy 170.111928 129.92) + (xy 170.124188 130.044482) (xy 170.160498 130.16418) (xy 170.219463 130.274494) (xy 170.298815 130.371185) (xy 170.395506 130.450537) + (xy 170.50582 130.509502) (xy 170.625518 130.545812) (xy 170.75 130.558072) (xy 172.46327 130.558072) (xy 173.404201 131.499003) + (xy 173.427999 131.528001) (xy 173.543724 131.622974) (xy 173.675753 131.693546) (xy 173.819014 131.737003) (xy 173.930667 131.748) + (xy 173.930675 131.748) (xy 173.968 131.751676) (xy 174.005325 131.748) (xy 176.955843 131.748) (xy 177.05944 131.790911) + (xy 177.22076 131.823) (xy 177.253424 131.823) (xy 177.262089 131.86656) (xy 177.325033 132.018521) (xy 177.416413 132.155281) + (xy 177.532719 132.271587) (xy 177.669479 132.362967) (xy 177.82144 132.425911) (xy 177.98276 132.458) (xy 178.14724 132.458) + (xy 178.30856 132.425911) (xy 178.412157 132.383) (xy 180.569678 132.383) (xy 180.607 132.386676) (xy 180.644322 132.383) + (xy 180.644333 132.383) (xy 180.755986 132.372003) (xy 180.899247 132.328546) (xy 181.031276 132.257974) (xy 181.147001 132.163001) + (xy 181.170804 132.133997) (xy 185.111003 128.193799) (xy 185.140001 128.170001) (xy 185.234974 128.054276) (xy 185.254326 128.018072) + (xy 185.75 128.018072) (xy 185.874482 128.005812) (xy 185.99418 127.969502) (xy 186.104494 127.910537) (xy 186.201185 127.831185) + (xy 186.280537 127.734494) (xy 186.339502 127.62418) (xy 186.375812 127.504482) (xy 186.388072 127.38) (xy 186.388072 125.38) + (xy 186.375812 125.255518) (xy 186.339502 125.13582) (xy 186.280537 125.025506) (xy 186.201185 124.928815) (xy 186.104494 124.849463) + (xy 185.99418 124.790498) (xy 185.874482 124.754188) (xy 185.75 124.741928) (xy 183.956887 124.741928) (xy 184.084609 124.550779) + (xy 184.204089 124.262327) (xy 184.265 123.956109) (xy 184.265 123.643891) (xy 184.204089 123.337673) (xy 184.084609 123.049221) + (xy 183.91115 122.789621) (xy 183.90153 122.780001) (xy 189.154677 122.780001) (xy 189.191999 122.783677) (xy 189.229321 122.780001) + (xy 189.229332 122.780001) (xy 189.340985 122.769004) (xy 189.484246 122.725547) (xy 189.616275 122.654975) (xy 189.732 122.560002) + (xy 189.755803 122.530998) (xy 191.590324 120.696478) (xy 191.693921 120.653567) (xy 191.830681 120.562187) (xy 191.946987 120.445881) + (xy 192.038367 120.309121) (xy 192.101311 120.15716) (xy 192.1334 119.99584) (xy 192.1334 119.83136) (xy 192.101311 119.67004) + (xy 192.045376 119.535) (xy 200.965531 119.535) (xy 201.009 119.539281) (xy 201.052469 119.535) (xy 201.052477 119.535) + (xy 201.18249 119.522195) (xy 201.349313 119.471589) (xy 201.503059 119.389411) (xy 201.637817 119.278817) (xy 201.665534 119.245044) + (xy 206.345051 114.565528) (xy 206.378817 114.537817) (xy 206.410672 114.499003) (xy 206.471195 114.425255) (xy 206.489411 114.403059) + (xy 206.571589 114.249313) (xy 206.622195 114.08249) (xy 206.635 113.952477) (xy 206.635 113.952467) (xy 206.639281 113.909001) + (xy 206.635 113.865535) (xy 206.635 105.76) (xy 207.38821 105.76) (xy 207.370506 105.769463) (xy 207.273815 105.848815) + (xy 207.194463 105.945506) (xy 207.135498 106.05582) (xy 207.099188 106.175518) (xy 207.086928 106.3) (xy 207.086928 107.6) + (xy 207.099188 107.724482) (xy 207.135498 107.84418) (xy 207.194463 107.954494) (xy 207.24 108.009982) (xy 207.24 108.252843) + (xy 207.197089 108.35644) (xy 207.165 108.51776) (xy 207.165 108.68224) (xy 207.197089 108.84356) (xy 207.24 108.947157) + (xy 207.240001 113.642073) (xy 207.215 113.76776) (xy 207.215 113.93224) (xy 207.247089 114.09356) (xy 207.290001 114.197159) + (xy 207.29 115.572215) (xy 207.286324 115.609538) (xy 207.29 115.64686) (xy 207.29 115.64687) (xy 207.300997 115.758523) + (xy 207.33379 115.866628) (xy 207.344454 115.901784) (xy 207.415026 116.033814) (xy 207.445696 116.071185) (xy 207.509999 116.149539) + (xy 207.539003 116.173342) (xy 208.901673 117.536013) (xy 208.925471 117.565011) (xy 209.041196 117.659984) (xy 209.173225 117.730556) + (xy 209.316486 117.774013) (xy 209.428139 117.78501) (xy 209.428147 117.78501) (xy 209.465472 117.788686) (xy 209.502797 117.78501) + (xy 210.21468 117.78501) (xy 210.252002 117.788686) (xy 210.289324 117.78501) (xy 210.289335 117.78501) (xy 210.400988 117.774013) + (xy 210.447183 117.76) (xy 220.962678 117.76) (xy 221 117.763676) (xy 221.037322 117.76) (xy 221.037333 117.76) + (xy 221.148986 117.749003) (xy 221.292247 117.705546) (xy 221.424276 117.634974) (xy 221.540001 117.540001) (xy 221.563804 117.510997) + (xy 223.261003 115.813799) (xy 223.290001 115.790001) (xy 223.384974 115.674276) (xy 223.455546 115.542247) (xy 223.499003 115.398986) + (xy 223.51 115.287333) (xy 223.51 115.287325) (xy 223.513676 115.25) (xy 223.51 115.212675) (xy 223.51 113.718072) + (xy 223.9 113.718072) (xy 224.024482 113.705812) (xy 224.14418 113.669502) (xy 224.254494 113.610537) (xy 224.351185 113.531185) + (xy 224.430537 113.434494) (xy 224.489502 113.32418) (xy 224.525812 113.204482) (xy 224.538072 113.08) (xy 224.538072 111.08) + (xy 224.525812 110.955518) (xy 224.489502 110.83582) (xy 224.430537 110.725506) (xy 224.351185 110.628815) (xy 224.254494 110.549463) + (xy 224.14418 110.490498) (xy 224.024482 110.454188) (xy 223.9 110.441928) (xy 222.106887 110.441928) (xy 222.234609 110.250779) + (xy 222.354089 109.962327) (xy 222.415 109.656109) (xy 222.415 109.343891) (xy 222.354089 109.037673) (xy 222.234609 108.749221) + (xy 222.06115 108.489621) (xy 221.840379 108.26885) (xy 221.580779 108.095391) (xy 221.292327 107.975911) (xy 220.986109 107.915) + (xy 220.673891 107.915) (xy 220.367673 107.975911) (xy 220.273303 108.015) (xy 220.10374 108.015) (xy 219.816842 108.072068) + (xy 219.546589 108.18401) (xy 219.303368 108.346525) (xy 219.096525 108.553368) (xy 218.93401 108.796589) (xy 218.822068 109.066842) + (xy 218.765 109.35374) (xy 218.765 109.64626) (xy 218.822068 109.933158) (xy 218.857988 110.019876) (xy 218.548698 110.147988) + (xy 218.326252 110.296622) (xy 218.331817 110.283186) (xy 218.435 109.764449) (xy 218.435 109.235551) (xy 218.331817 108.716814) + (xy 218.129417 108.228175) (xy 217.835576 107.788412) (xy 217.461588 107.414424) (xy 217.021825 107.120583) (xy 216.5762 106.936) + (xy 217.465123 106.936) (xy 217.5 106.939435) (xy 217.534877 106.936) (xy 217.581076 106.93145) (xy 217.639184 106.925727) + (xy 217.77302 106.885128) (xy 217.896363 106.8192) (xy 218.004475 106.730475) (xy 218.0932 106.622363) (xy 218.159128 106.49902) + (xy 218.199727 106.365184) (xy 218.21 106.260877) (xy 218.21 106.260876) (xy 218.213435 106.226) (xy 218.21 106.191123) + (xy 218.21 106.013072) (xy 218.95 106.013072) (xy 219.074482 106.000812) (xy 219.19418 105.964502) (xy 219.304494 105.905537) + (xy 219.401185 105.826185) (xy 219.480537 105.729494) (xy 219.539502 105.61918) (xy 219.562634 105.542923) (xy 219.624276 105.509974) + (xy 219.740001 105.415001) (xy 219.763804 105.385997) (xy 219.935998 105.213803) (xy 219.965001 105.190001) (xy 220.059974 105.074276) + (xy 220.130546 104.942247) (xy 220.174003 104.798986) (xy 220.185 104.687333) (xy 220.185 104.687324) (xy 220.188676 104.650001) + (xy 220.185 104.612678) (xy 220.185 103.472157) (xy 220.227911 103.36856) (xy 220.26 103.20724) (xy 220.26 103.04276) + (xy 220.227911 102.88144) (xy 220.164967 102.729479) (xy 220.073587 102.592719) (xy 219.957281 102.476413) (xy 219.820521 102.385033) + (xy 219.66856 102.322089) (xy 219.50724 102.29) (xy 219.490957 102.29) (xy 219.480537 102.270506) (xy 219.401185 102.173815) + (xy 219.304494 102.094463) (xy 219.19418 102.035498) (xy 219.074482 101.999188) (xy 218.95 101.986928) (xy 218.43575 101.99) + (xy 218.277002 102.148748) (xy 218.277002 101.99) (xy 218.21 101.99) (xy 218.21 101.760877) (xy 218.213435 101.726) + (xy 218.199727 101.586816) (xy 218.159128 101.45298) (xy 218.0932 101.329637) (xy 218.004475 101.221525) (xy 217.896363 101.1328) + (xy 217.77302 101.066872) (xy 217.639184 101.026273) (xy 217.534877 101.016) (xy 217.5 101.012565) (xy 217.465123 101.016) + (xy 214.034877 101.016) (xy 214 101.012565) (xy 213.965123 101.016) (xy 213.860816 101.026273) (xy 213.72698 101.066872) + (xy 213.603637 101.1328) (xy 213.495525 101.221525) (xy 213.4068 101.329637) (xy 213.340872 101.45298) (xy 213.300273 101.586816) + (xy 213.286565 101.726) (xy 213.290001 101.760887) (xy 213.290001 101.986928) (xy 212.55 101.986928) (xy 212.425518 101.999188) + (xy 212.30582 102.035498) (xy 212.195506 102.094463) (xy 212.098815 102.173815) (xy 212.019463 102.270506) (xy 211.960498 102.38082) + (xy 211.924188 102.500518) (xy 211.911928 102.625) (xy 211.911928 103.286241) (xy 211.854489 103.310033) (xy 211.717729 103.401413) + (xy 211.601423 103.517719) (xy 211.510043 103.654479) (xy 211.447099 103.80644) (xy 211.41501 103.96776) (xy 211.41501 103.99) + (xy 209.313072 103.99) (xy 209.313072 102.75) (xy 209.300812 102.625518) (xy 209.264502 102.50582) (xy 209.205537 102.395506) + (xy 209.126185 102.298815) (xy 209.029494 102.219463) (xy 208.91918 102.160498) (xy 208.799482 102.124188) (xy 208.675 102.111928) + (xy 208.109499 102.111928) (xy 208.318601 101.902826) (xy 208.645273 101.413928) (xy 208.870288 100.870692) (xy 208.985 100.293997) + (xy 208.985 99.706003) (xy 208.870288 99.129308) (xy 208.645273 98.586072) (xy 208.318601 98.097174) (xy 207.902826 97.681399) + (xy 207.413928 97.354727) (xy 206.870692 97.129712) (xy 206.293997 97.015) (xy 205.706003 97.015) (xy 205.129308 97.129712) + (xy 204.586072 97.354727) (xy 204.097174 97.681399) (xy 203.681399 98.097174) (xy 203.354727 98.586072) (xy 203.135 99.116542) + (xy 203.135 97.992178) (xy 206.453989 94.67319) (xy 206.515313 94.654587) (xy 206.669059 94.572409) (xy 206.803817 94.461815) + (xy 206.914411 94.327057) (xy 206.996589 94.173311) (xy 207.047195 94.006488) (xy 207.06 93.876475) (xy 207.06 93.744067) + (xy 207.064281 93.700601) (xy 207.06 93.657135) (xy 207.06 89.720302) (xy 207.101413 89.782281) (xy 207.217719 89.898587) + (xy 207.354479 89.989967) (xy 207.50644 90.052911) (xy 207.66776 90.085) (xy 207.83224 90.085) (xy 207.99356 90.052911) + (xy 208.145521 89.989967) (xy 208.282281 89.898587) (xy 208.398587 89.782281) (xy 208.489967 89.645521) (xy 208.552911 89.49356) + (xy 208.585 89.33224) (xy 208.585 89.226018) (xy 208.676185 89.151185) (xy 208.755537 89.054494) (xy 208.814502 88.94418) + (xy 208.850812 88.824482) (xy 208.863072 88.7) (xy 208.863072 87.4) (xy 208.850812 87.275518) (xy 208.814502 87.15582) + (xy 208.755537 87.045506) (xy 208.676185 86.948815) (xy 208.579494 86.869463) (xy 208.46918 86.810498) (xy 208.349482 86.774188) + (xy 208.225 86.761928) (xy 207.275 86.761928) (xy 207.150518 86.774188) (xy 207.06 86.801646) (xy 207.06 86.76) + (xy 211.994499 86.76) (xy 212.048815 86.826185) (xy 212.145506 86.905537) (xy 212.25582 86.964502) (xy 212.375518 87.000812) + (xy 212.5 87.013072) (xy 213.24 87.013072) (xy 213.24 87.254623) (xy 213.236565 87.2895) (xy 213.250273 87.428684) + (xy 213.290872 87.56252) (xy 213.3568 87.685863) (xy 213.445525 87.793975) (xy 213.553113 87.88227) (xy 213.553637 87.8827) + (xy 213.67698 87.948628) (xy 213.810816 87.989227) (xy 213.95 88.002935) (xy 213.984877 87.9995) (xy 214.720497 87.9995) + (xy 214.428175 88.120583) (xy 213.988412 88.414424) (xy 213.614424 88.788412) (xy 213.320583 89.228175) (xy 213.118183 89.716814) + (xy 213.015 90.235551) (xy 213.015 90.764449) (xy 213.118183 91.283186) (xy 213.123749 91.296623) (xy 212.901302 91.147989) + (xy 212.592012 91.019877) (xy 212.627932 90.933158) (xy 212.685 90.64626) (xy 212.685 90.35374) (xy 212.627932 90.066842) + (xy 212.51599 89.796589) (xy 212.353475 89.553368) (xy 212.146632 89.346525) (xy 211.903411 89.18401) (xy 211.633158 89.072068) + (xy 211.34626 89.015) (xy 211.176697 89.015) (xy 211.082327 88.975911) (xy 210.776109 88.915) (xy 210.463891 88.915) + (xy 210.157673 88.975911) (xy 209.869221 89.095391) (xy 209.609621 89.26885) (xy 209.38885 89.489621) (xy 209.215391 89.749221) + (xy 209.095911 90.037673) (xy 209.035 90.343891) (xy 209.035 90.656109) (xy 209.095911 90.962327) (xy 209.215391 91.250779) + (xy 209.38885 91.510379) (xy 209.609621 91.73115) (xy 209.869221 91.904609) (xy 210.035016 91.973283) (xy 209.997988 92.028699) + (xy 209.837047 92.417245) (xy 209.755 92.829722) (xy 209.755 93.25028) (xy 209.837047 93.662757) (xy 209.969252 93.981928) + (xy 208.85 93.981928) (xy 208.725518 93.994188) (xy 208.60582 94.030498) (xy 208.495506 94.089463) (xy 208.398815 94.168815) + (xy 208.319463 94.265506) (xy 208.260498 94.37582) (xy 208.224188 94.495518) (xy 208.211928 94.62) (xy 208.211928 96.62) + (xy 208.224188 96.744482) (xy 208.260498 96.86418) (xy 208.319463 96.974494) (xy 208.398815 97.071185) (xy 208.495506 97.150537) + (xy 208.60582 97.209502) (xy 208.725518 97.245812) (xy 208.85 97.258072) (xy 208.946764 97.258072) (xy 208.915 97.41776) + (xy 208.915 97.58224) (xy 208.947089 97.74356) (xy 209.010033 97.895521) (xy 209.101413 98.032281) (xy 209.217719 98.148587) + (xy 209.354479 98.239967) (xy 209.458077 98.282879) (xy 209.961202 98.786003) (xy 209.985 98.815002) (xy 210.013998 98.8388) + (xy 210.100724 98.909975) (xy 210.215353 98.971246) (xy 210.232754 98.980547) (xy 210.376015 99.024004) (xy 210.487668 99.035001) + (xy 210.487678 99.035001) (xy 210.525001 99.038677) (xy 210.562324 99.035001) (xy 220.964679 99.035001) (xy 221.002001 99.038677) + (xy 221.039323 99.035001) (xy 221.039334 99.035001) (xy 221.150987 99.024004) (xy 221.294248 98.980547) (xy 221.426277 98.909975) + (xy 221.542002 98.815002) (xy 221.565805 98.785998) (xy 223.211003 97.140801) (xy 223.240001 97.117003) (xy 223.334974 97.001278) + (xy 223.405546 96.869249) (xy 223.449003 96.725988) (xy 223.46 96.614335) (xy 223.46 96.614326) (xy 223.463676 96.577003) + (xy 223.46 96.53968) (xy 223.46 94.718072) (xy 223.85 94.718072) (xy 223.974482 94.705812) (xy 224.09418 94.669502) + (xy 224.204494 94.610537) (xy 224.301185 94.531185) (xy 224.380537 94.434494) (xy 224.439502 94.32418) (xy 224.475812 94.204482) + (xy 224.488072 94.08) (xy 224.488072 92.08) (xy 224.475812 91.955518) (xy 224.439502 91.83582) (xy 224.380537 91.725506) + (xy 224.301185 91.628815) (xy 224.204494 91.549463) (xy 224.09418 91.490498) (xy 223.974482 91.454188) (xy 223.85 91.441928) + (xy 222.056887 91.441928) (xy 222.184609 91.250779) (xy 222.304089 90.962327) (xy 222.365 90.656109) (xy 222.365 90.343891) + (xy 222.304089 90.037673) (xy 222.184609 89.749221) (xy 222.01115 89.489621) (xy 221.790379 89.26885) (xy 221.530779 89.095391) + (xy 221.242327 88.975911) (xy 220.936109 88.915) (xy 220.623891 88.915) (xy 220.317673 88.975911) (xy 220.223303 89.015) + (xy 220.05374 89.015) (xy 219.766842 89.072068) (xy 219.496589 89.18401) (xy 219.253368 89.346525) (xy 219.046525 89.553368) + (xy 218.88401 89.796589) (xy 218.772068 90.066842) (xy 218.715 90.35374) (xy 218.715 90.64626) (xy 218.772068 90.933158) + (xy 218.807988 91.019876) (xy 218.498698 91.147988) (xy 218.276252 91.296622) (xy 218.281817 91.283186) (xy 218.385 90.764449) + (xy 218.385 90.235551) (xy 218.281817 89.716814) (xy 218.079417 89.228175) (xy 217.785576 88.788412) (xy 217.411588 88.414424) + (xy 216.971825 88.120583) (xy 216.679503 87.9995) (xy 217.415123 87.9995) (xy 217.45 88.002935) (xy 217.484877 87.9995) + (xy 217.589184 87.989227) (xy 217.72302 87.948628) (xy 217.846363 87.8827) (xy 217.954475 87.793975) (xy 218.0432 87.685863) + (xy 218.109128 87.56252) (xy 218.149727 87.428684) (xy 218.163435 87.2895) (xy 218.16 87.254623) (xy 218.16 87.013072) + (xy 218.9 87.013072) (xy 219.024482 87.000812) (xy 219.14418 86.964502) (xy 219.254494 86.905537) (xy 219.351185 86.826185) + (xy 219.430537 86.729494) (xy 219.489502 86.61918) (xy 219.507022 86.561423) (xy 219.603276 86.509974) (xy 219.719001 86.415001) + (xy 219.742803 86.385998) (xy 220.261004 85.867798) (xy 220.290001 85.844001) (xy 220.326601 85.799404) (xy 220.384974 85.728277) + (xy 220.455546 85.596247) (xy 220.461156 85.577753) (xy 220.499003 85.452986) (xy 220.51 85.341333) (xy 220.51 85.341323) + (xy 220.513676 85.304) (xy 220.51 85.266677) (xy 220.51 85.097157) (xy 220.552911 84.99356) (xy 220.585 84.83224) + (xy 220.585 84.66776) (xy 220.552911 84.50644) (xy 220.489967 84.354479) (xy 220.398587 84.217719) (xy 220.282281 84.101413) + (xy 220.145521 84.010033) (xy 219.99356 83.947089) (xy 219.83224 83.915) (xy 219.66776 83.915) (xy 219.50644 83.947089) + (xy 219.383534 83.997998) (xy 219.376252 83.997998) (xy 219.535 83.83925) (xy 219.538072 83.625) (xy 219.525812 83.500518) + (xy 219.489502 83.38082) (xy 219.430537 83.270506) (xy 219.351185 83.173815) (xy 219.254494 83.094463) (xy 219.14418 83.035498) + (xy 219.024482 82.999188) (xy 218.9 82.986928) (xy 218.38575 82.99) (xy 218.227002 83.148748) (xy 218.227002 82.99) + (xy 218.16 82.99) (xy 218.16 82.824377) (xy 218.163435 82.7895) (xy 218.149727 82.650316) (xy 218.109128 82.51648) + (xy 218.0432 82.393137) (xy 217.954475 82.285025) (xy 217.846363 82.1963) (xy 217.72302 82.130372) (xy 217.589184 82.089773) + (xy 217.484877 82.0795) (xy 217.45 82.076065) (xy 217.415123 82.0795) (xy 213.984877 82.0795) (xy 213.95 82.076065) + (xy 213.915123 82.0795) (xy 213.810816 82.089773) (xy 213.67698 82.130372) (xy 213.553637 82.1963) (xy 213.445525 82.285025) + (xy 213.3568 82.393137) (xy 213.290872 82.51648) (xy 213.250273 82.650316) (xy 213.236565 82.7895) (xy 213.240001 82.824387) + (xy 213.240001 82.986928) (xy 212.5 82.986928) (xy 212.375518 82.999188) (xy 212.25582 83.035498) (xy 212.145506 83.094463) + (xy 212.048815 83.173815) (xy 211.969463 83.270506) (xy 211.910498 83.38082) (xy 211.874188 83.500518) (xy 211.861928 83.625) + (xy 211.861928 84.116271) (xy 211.787235 84.190963) (xy 211.75644 84.197089) (xy 211.604479 84.260033) (xy 211.467719 84.351413) + (xy 211.351413 84.467719) (xy 211.260033 84.604479) (xy 211.197089 84.75644) (xy 211.165 84.91776) (xy 211.165 84.99) + (xy 208.863072 84.99) (xy 208.863072 83.85) (xy 208.850812 83.725518) (xy 208.814502 83.60582) (xy 208.755537 83.495506) + (xy 208.676185 83.398815) (xy 208.579494 83.319463) (xy 208.46918 83.260498) (xy 208.349482 83.224188) (xy 208.225 83.211928) + (xy 207.275 83.211928) (xy 207.150518 83.224188) (xy 207.06 83.251646) (xy 207.06 75.42) (xy 208.211928 75.42) + (xy 208.211928 77.42) (xy 208.224188 77.544482) (xy 208.260498 77.66418) (xy 208.319463 77.774494) (xy 208.398815 77.871185) + (xy 208.495506 77.950537) (xy 208.60582 78.009502) (xy 208.725518 78.045812) (xy 208.85 78.058072) (xy 210.413271 78.058072) + (xy 211.41619 79.060992) (xy 211.439988 79.08999) (xy 211.468986 79.113788) (xy 211.555713 79.184963) (xy 211.687742 79.255535) + (xy 211.831003 79.298992) (xy 211.979989 79.313666) (xy 212.017322 79.309989) (xy 215.222386 79.309989) (xy 215.224089 79.318549) + (xy 215.287033 79.47051) (xy 215.378413 79.60727) (xy 215.494719 79.723576) (xy 215.631479 79.814956) (xy 215.78344 79.8779) + (xy 215.94476 79.909989) (xy 216.10924 79.909989) (xy 216.27056 79.8779) (xy 216.374157 79.834989) (xy 221.087689 79.834989) + (xy 221.125011 79.838665) (xy 221.162333 79.834989) (xy 221.162344 79.834989) (xy 221.273997 79.823992) (xy 221.417258 79.780535) + (xy 221.549287 79.709963) (xy 221.665012 79.61499) (xy 221.688814 79.585987) (xy 223.261008 78.013795) (xy 223.290001 77.990001) + (xy 223.313795 77.961008) (xy 223.313799 77.961004) (xy 223.384973 77.874277) (xy 223.385119 77.874004) (xy 223.455546 77.742247) + (xy 223.499003 77.598986) (xy 223.51 77.487333) (xy 223.51 77.487324) (xy 223.513676 77.450001) (xy 223.51 77.412678) + (xy 223.51 75.518072) (xy 223.85 75.518072) (xy 223.974482 75.505812) (xy 224.09418 75.469502) (xy 224.204494 75.410537) + (xy 224.301185 75.331185) (xy 224.380537 75.234494) (xy 224.439502 75.12418) (xy 224.475812 75.004482) (xy 224.488072 74.88) + (xy 224.488072 72.88) (xy 224.475812 72.755518) (xy 224.439502 72.63582) (xy 224.380537 72.525506) (xy 224.301185 72.428815) + (xy 224.204494 72.349463) (xy 224.09418 72.290498) (xy 223.974482 72.254188) (xy 223.85 72.241928) (xy 222.056887 72.241928) + (xy 222.184609 72.050779) (xy 222.304089 71.762327) (xy 222.365 71.456109) (xy 222.365 71.143891) (xy 222.304089 70.837673) + (xy 222.184609 70.549221) (xy 222.01115 70.289621) (xy 221.790379 70.06885) (xy 221.530779 69.895391) (xy 221.242327 69.775911) + (xy 220.936109 69.715) (xy 220.623891 69.715) (xy 220.317673 69.775911) (xy 220.223303 69.815) (xy 220.05374 69.815) + (xy 219.766842 69.872068) (xy 219.496589 69.98401) (xy 219.253368 70.146525) (xy 219.046525 70.353368) (xy 218.88401 70.596589) + (xy 218.772068 70.866842) (xy 218.715 71.15374) (xy 218.715 71.44626) (xy 218.772068 71.733158) (xy 218.807988 71.819876) + (xy 218.498698 71.947988) (xy 218.276252 72.096622) (xy 218.281817 72.083186) (xy 218.385 71.564449) (xy 218.385 71.035551) + (xy 218.281817 70.516814) (xy 218.079417 70.028175) (xy 217.785576 69.588412) (xy 217.411588 69.214424) (xy 216.971825 68.920583) + (xy 216.5262 68.736) (xy 217.415123 68.736) (xy 217.45 68.739435) (xy 217.484877 68.736) (xy 217.532731 68.731287) + (xy 217.589184 68.725727) (xy 217.72302 68.685128) (xy 217.846363 68.6192) (xy 217.954475 68.530475) (xy 218.0432 68.422363) + (xy 218.109128 68.29902) (xy 218.149727 68.165184) (xy 218.156716 68.094224) (xy 218.163435 68.026) (xy 218.16 67.991123) + (xy 218.16 67.813072) (xy 218.9 67.813072) (xy 219.024482 67.800812) (xy 219.14418 67.764502) (xy 219.254494 67.705537) + (xy 219.351185 67.626185) (xy 219.430537 67.529494) (xy 219.489502 67.41918) (xy 219.525812 67.299482) (xy 219.527021 67.287204) + (xy 219.615001 67.215001) (xy 219.638804 67.185997) (xy 220.030498 66.794303) (xy 220.059501 66.770501) (xy 220.13008 66.6845) + (xy 220.154474 66.654777) (xy 220.225046 66.522747) (xy 220.233305 66.495521) (xy 220.268503 66.379486) (xy 220.2795 66.267833) + (xy 220.2795 66.267823) (xy 220.283176 66.2305) (xy 220.279777 66.195988) (xy 220.322411 66.09306) (xy 220.3545 65.93174) + (xy 220.3545 65.76726) (xy 220.322411 65.60594) (xy 220.259467 65.453979) (xy 220.168087 65.317219) (xy 220.051781 65.200913) + (xy 219.915021 65.109533) (xy 219.76306 65.046589) (xy 219.60174 65.0145) (xy 219.43726 65.0145) (xy 219.27594 65.046589) + (xy 219.262877 65.052) (xy 218.227 65.052) (xy 218.227 65.072) (xy 218.16 65.072) (xy 218.16 64.778) + (xy 218.227 64.778) (xy 218.227 64.798) (xy 219.37625 64.798) (xy 219.535 64.63925) (xy 219.538072 64.425) + (xy 219.525812 64.300518) (xy 219.489502 64.18082) (xy 219.430537 64.070506) (xy 219.351185 63.973815) (xy 219.254494 63.894463) + (xy 219.14418 63.835498) (xy 219.024482 63.799188) (xy 218.9 63.786928) (xy 218.38575 63.79) (xy 218.227002 63.948748) + (xy 218.227002 63.79) (xy 218.16 63.79) (xy 218.16 63.560877) (xy 218.163435 63.526) (xy 218.149727 63.386816) + (xy 218.109128 63.25298) (xy 218.0432 63.129637) (xy 217.954475 63.021525) (xy 217.846363 62.9328) (xy 217.72302 62.866872) + (xy 217.589184 62.826273) (xy 217.484877 62.816) (xy 217.45 62.812565) (xy 217.415123 62.816) (xy 213.984877 62.816) + (xy 213.95 62.812565) (xy 213.915123 62.816) (xy 213.810816 62.826273) (xy 213.67698 62.866872) (xy 213.553637 62.9328) + (xy 213.445525 63.021525) (xy 213.3568 63.129637) (xy 213.290872 63.25298) (xy 213.250273 63.386816) (xy 213.236565 63.526) + (xy 213.240001 63.560887) (xy 213.240001 63.786928) (xy 212.5 63.786928) (xy 212.375518 63.799188) (xy 212.25582 63.835498) + (xy 212.145506 63.894463) (xy 212.048815 63.973815) (xy 211.969463 64.070506) (xy 211.918954 64.165) (xy 211.762325 64.165) + (xy 211.725 64.161324) (xy 211.687675 64.165) (xy 211.687667 64.165) (xy 211.576014 64.175997) (xy 211.432753 64.219454) + (xy 211.300724 64.290026) (xy 211.184999 64.384999) (xy 211.161201 64.413998) (xy 210.440404 65.134795) (xy 210.411401 65.158597) + (xy 210.363269 65.217247) (xy 210.316428 65.274322) (xy 210.264952 65.370626) (xy 210.245856 65.406352) (xy 210.202399 65.549613) + (xy 210.191402 65.661266) (xy 210.191402 65.661276) (xy 210.187726 65.698598) (xy 210.191402 65.735921) (xy 210.191403 66.602841) + (xy 210.148491 66.70644) (xy 210.116402 66.86776) (xy 210.116402 67.03224) (xy 210.148491 67.19356) (xy 210.211435 67.345521) + (xy 210.302815 67.482281) (xy 210.419121 67.598587) (xy 210.555881 67.689967) (xy 210.65948 67.732879) (xy 212.240001 69.313401) + (xy 212.240001 70.239894) (xy 212.146632 70.146525) (xy 211.903411 69.98401) (xy 211.633158 69.872068) (xy 211.34626 69.815) + (xy 211.176697 69.815) (xy 211.082327 69.775911) (xy 210.776109 69.715) (xy 210.463891 69.715) (xy 210.157673 69.775911) + (xy 209.869221 69.895391) (xy 209.609621 70.06885) (xy 209.38885 70.289621) (xy 209.215391 70.549221) (xy 209.095911 70.837673) + (xy 209.035 71.143891) (xy 209.035 71.456109) (xy 209.095911 71.762327) (xy 209.215391 72.050779) (xy 209.38885 72.310379) + (xy 209.609621 72.53115) (xy 209.869221 72.704609) (xy 210.035016 72.773283) (xy 209.997988 72.828699) (xy 209.837047 73.217245) + (xy 209.755 73.629722) (xy 209.755 74.05028) (xy 209.837047 74.462757) (xy 209.969252 74.781928) (xy 208.85 74.781928) + (xy 208.725518 74.794188) (xy 208.60582 74.830498) (xy 208.495506 74.889463) (xy 208.398815 74.968815) (xy 208.319463 75.065506) + (xy 208.260498 75.17582) (xy 208.224188 75.295518) (xy 208.211928 75.42) (xy 207.06 75.42) (xy 207.06 70.970302) + (xy 207.101413 71.032281) (xy 207.217719 71.148587) (xy 207.354479 71.239967) (xy 207.50644 71.302911) (xy 207.66776 71.335) + (xy 207.83224 71.335) (xy 207.99356 71.302911) (xy 208.145521 71.239967) (xy 208.282281 71.148587) (xy 208.398587 71.032281) + (xy 208.489967 70.895521) (xy 208.552911 70.74356) (xy 208.585 70.58224) (xy 208.585 70.41776) (xy 208.552911 70.25644) + (xy 208.548945 70.246866) (xy 208.579494 70.230537) (xy 208.676185 70.151185) (xy 208.755537 70.054494) (xy 208.814502 69.94418) + (xy 208.850812 69.824482) (xy 208.863072 69.7) (xy 208.863072 68.4) (xy 208.850812 68.275518) (xy 208.814502 68.15582) + (xy 208.755537 68.045506) (xy 208.676185 67.948815) (xy 208.579494 67.869463) (xy 208.46918 67.810498) (xy 208.349482 67.774188) + (xy 208.225 67.761928) (xy 207.275 67.761928) (xy 207.150518 67.774188) (xy 207.06 67.801646) (xy 207.06 66.748354) + (xy 207.150518 66.775812) (xy 207.275 66.788072) (xy 208.225 66.788072) (xy 208.349482 66.775812) (xy 208.46918 66.739502) + (xy 208.579494 66.680537) (xy 208.676185 66.601185) (xy 208.755537 66.504494) (xy 208.814502 66.39418) (xy 208.850812 66.274482) + (xy 208.863072 66.15) (xy 208.863072 64.85) (xy 208.850812 64.725518) (xy 208.814502 64.60582) (xy 208.755537 64.495506) + (xy 208.676185 64.398815) (xy 208.579494 64.319463) (xy 208.46918 64.260498) (xy 208.349482 64.224188) (xy 208.225 64.211928) + (xy 207.275 64.211928) (xy 207.246148 64.21477) (xy 207.413928 64.145273) (xy 207.902826 63.818601) (xy 208.318601 63.402826) + (xy 208.645273 62.913928) (xy 208.870288 62.370692) (xy 208.985 61.793997) (xy 208.985 61.206003) (xy 208.870288 60.629308) + (xy 208.645273 60.086072) (xy 208.318601 59.597174) (xy 207.902826 59.181399) (xy 207.413928 58.854727) (xy 206.870692 58.629712) + (xy 206.293997 58.515) (xy 205.706003 58.515) (xy 205.129308 58.629712) (xy 204.586072 58.854727) (xy 204.097174 59.181399) + (xy 203.705511 59.573062) (xy 203.705511 59.296067) (xy 206.59505 56.406529) (xy 206.628817 56.378817) (xy 206.663793 56.3362) + (xy 206.73941 56.24406) (xy 206.739411 56.244059) (xy 206.821589 56.090313) (xy 206.872195 55.92349) (xy 206.885 55.793477) + (xy 206.885 55.793467) (xy 206.889281 55.750001) (xy 206.885 55.706535) (xy 206.885 52.951398) (xy 206.915 52.976018) + (xy 206.915 53.08224) (xy 206.947089 53.24356) (xy 207.010033 53.395521) (xy 207.101413 53.532281) (xy 207.217719 53.648587) + (xy 207.354479 53.739967) (xy 207.50644 53.802911) (xy 207.66776 53.835) (xy 207.83224 53.835) (xy 207.99356 53.802911) + (xy 208.145521 53.739967) (xy 208.282281 53.648587) (xy 208.398587 53.532281) (xy 208.489967 53.395521) (xy 208.49 53.395441) + (xy 208.49 56.079556) (xy 208.419463 56.165506) (xy 208.360498 56.27582) (xy 208.324188 56.395518) (xy 208.311928 56.52) + (xy 208.311928 58.52) (xy 208.324188 58.644482) (xy 208.360498 58.76418) (xy 208.419463 58.874494) (xy 208.498815 58.971185) + (xy 208.595506 59.050537) (xy 208.70582 59.109502) (xy 208.825518 59.145812) (xy 208.95 59.158072) (xy 210.56327 59.158072) + (xy 211.682401 60.277203) (xy 211.706199 60.306201) (xy 211.821924 60.401174) (xy 211.953953 60.471746) (xy 212.097214 60.515203) + (xy 212.208867 60.5262) (xy 212.208875 60.5262) (xy 212.2462 60.529876) (xy 212.283525 60.5262) (xy 213.850784 60.5262) + (xy 213.852489 60.53477) (xy 213.915433 60.686731) (xy 214.006813 60.823491) (xy 214.123119 60.939797) (xy 214.259879 61.031177) + (xy 214.41184 61.094121) (xy 214.57316 61.12621) (xy 214.73764 61.12621) (xy 214.89896 61.094121) (xy 215.002557 61.05121) + (xy 220.671468 61.05121) (xy 220.70879 61.054886) (xy 220.746112 61.05121) (xy 220.746123 61.05121) (xy 220.857776 61.040213) + (xy 221.001037 60.996756) (xy 221.133066 60.926184) (xy 221.248791 60.831211) (xy 221.272594 60.802207) (xy 223.211003 58.863799) + (xy 223.240001 58.840001) (xy 223.334974 58.724276) (xy 223.405546 58.592247) (xy 223.449003 58.448986) (xy 223.46 58.337333) + (xy 223.46 58.337324) (xy 223.463676 58.300001) (xy 223.46 58.262678) (xy 223.46 56.618072) (xy 223.95 56.618072) + (xy 224.074482 56.605812) (xy 224.19418 56.569502) (xy 224.304494 56.510537) (xy 224.401185 56.431185) (xy 224.480537 56.334494) + (xy 224.539502 56.22418) (xy 224.575812 56.104482) (xy 224.588072 55.98) (xy 224.588072 53.98) (xy 224.575812 53.855518) + (xy 224.539502 53.73582) (xy 224.480537 53.625506) (xy 224.401185 53.528815) (xy 224.304494 53.449463) (xy 224.19418 53.390498) + (xy 224.074482 53.354188) (xy 223.95 53.341928) (xy 222.156887 53.341928) (xy 222.284609 53.150779) (xy 222.404089 52.862327) + (xy 222.465 52.556109) (xy 222.465 52.243891) (xy 222.404089 51.937673) (xy 222.284609 51.649221) (xy 222.11115 51.389621) + (xy 221.890379 51.16885) (xy 221.630779 50.995391) (xy 221.342327 50.875911) (xy 221.036109 50.815) (xy 220.723891 50.815) + (xy 220.417673 50.875911) (xy 220.323303 50.915) (xy 220.15374 50.915) (xy 219.866842 50.972068) (xy 219.596589 51.08401) + (xy 219.353368 51.246525) (xy 219.146525 51.453368) (xy 218.98401 51.696589) (xy 218.872068 51.966842) (xy 218.815 52.25374) + (xy 218.815 52.54626) (xy 218.872068 52.833158) (xy 218.907988 52.919876) (xy 218.598698 53.047988) (xy 218.376252 53.196622) + (xy 218.381817 53.183186) (xy 218.485 52.664449) (xy 218.485 52.135551) (xy 218.381817 51.616814) (xy 218.179417 51.128175) + (xy 217.885576 50.688412) (xy 217.511588 50.314424) (xy 217.071825 50.020583) (xy 216.687522 49.8614) (xy 217.415123 49.8614) + (xy 217.45 49.864835) (xy 217.484877 49.8614) (xy 217.589184 49.851127) (xy 217.72302 49.810528) (xy 217.846363 49.7446) + (xy 217.954475 49.655875) (xy 218.0432 49.547763) (xy 218.109128 49.42442) (xy 218.149727 49.290584) (xy 218.163435 49.1514) + (xy 218.16 49.116523) (xy 218.16 48.913072) (xy 219 48.913072) (xy 219.124482 48.900812) (xy 219.24418 48.864502) + (xy 219.354494 48.805537) (xy 219.451185 48.726185) (xy 219.530537 48.629494) (xy 219.589502 48.51918) (xy 219.625812 48.399482) + (xy 219.638072 48.275) (xy 219.638072 47.804003) (xy 219.64356 47.802911) (xy 219.795521 47.739967) (xy 219.932281 47.648587) + (xy 220.048587 47.532281) (xy 220.139967 47.395521) (xy 220.202911 47.24356) (xy 220.235 47.08224) (xy 220.235 46.91776) + (xy 220.202911 46.75644) (xy 220.139967 46.604479) (xy 220.048587 46.467719) (xy 219.932281 46.351413) (xy 219.795521 46.260033) + (xy 219.64356 46.197089) (xy 219.490991 46.166741) (xy 219.47625 46.152) (xy 218.327 46.152) (xy 218.327 46.172) + (xy 218.16 46.172) (xy 218.16 45.878) (xy 218.327 45.878) (xy 218.327 45.898) (xy 219.47625 45.898) + (xy 219.635 45.73925) (xy 219.638072 45.525) (xy 219.625812 45.400518) (xy 219.589502 45.28082) (xy 219.530537 45.170506) + (xy 219.451185 45.073815) (xy 219.354494 44.994463) (xy 219.24418 44.935498) (xy 219.124482 44.899188) (xy 219.07402 44.894218) + (xy 219.139967 44.795521) (xy 219.202911 44.64356) (xy 219.235 44.48224) (xy 219.235 44.31776) (xy 219.202911 44.15644) + (xy 219.139967 44.004479) (xy 219.048587 43.867719) (xy 218.932281 43.751413) (xy 218.795521 43.660033) (xy 218.683506 43.613635) + (xy 218.624277 43.565027) (xy 218.492248 43.494455) (xy 218.348987 43.450998) (xy 218.237334 43.440001) (xy 218.237323 43.440001) + (xy 218.200001 43.436325) (xy 218.162679 43.440001) (xy 211.837324 43.440001) (xy 211.799999 43.436325) (xy 211.762674 43.440001) + (xy 211.762666 43.440001) (xy 211.651013 43.450998) (xy 211.507752 43.494455) (xy 211.375723 43.565027) (xy 211.259998 43.66) + (xy 211.236195 43.689004) (xy 210.978803 43.946396) (xy 210.978797 43.946401) (xy 210.01 44.915199) (xy 210.01 44.873122) + (xy 210.013676 44.835799) (xy 210.01 44.798476) (xy 210.01 44.798467) (xy 209.999003 44.686814) (xy 209.955546 44.543553) + (xy 209.884974 44.411524) (xy 209.864029 44.386002) (xy 209.813799 44.324796) (xy 209.813795 44.324792) (xy 209.790001 44.295799) + (xy 209.761008 44.272005) (xy 208.564403 43.075402) (xy 208.540601 43.046399) (xy 208.424876 42.951426) (xy 208.292847 42.880854) + (xy 208.149586 42.837397) (xy 208.037933 42.8264) (xy 208.037922 42.8264) (xy 208.0006 42.822724) (xy 207.963278 42.8264) + (xy 194.551202 42.8264) (xy 190.503369 38.778568) + ) + ) + (filled_polygon + (pts + (xy 103.6686 128.39664) (xy 103.700689 128.55796) (xy 103.763633 128.709921) (xy 103.855013 128.846681) (xy 103.971319 128.962987) + (xy 104.108079 129.054367) (xy 104.26004 129.117311) (xy 104.42136 129.1494) (xy 104.58584 129.1494) (xy 104.74716 129.117311) + (xy 104.850757 129.0744) (xy 108.850798 129.0744) (xy 104.600292 133.324907) (xy 104.600253 133.324933) (xy 104.568436 133.35675) + (xy 104.539506 133.380492) (xy 104.515763 133.409423) (xy 104.483947 133.441239) (xy 104.45895 133.47865) (xy 104.455361 133.483023) + (xy 103.698385 134.24) (xy 103.514803 134.24) (xy 103.261276 133.986474) (xy 103.320649 133.890993) (xy 103.329993 133.866166) + (xy 103.356167 133.870487) (xy 103.481184 133.866395) (xy 103.603001 133.837991) (xy 103.716935 133.786368) (xy 103.900945 133.676582) + (xy 103.959052 133.459726) (xy 103.384427 132.464446) (xy 103.367106 132.474446) (xy 103.342981 132.432661) (xy 103.597593 132.285661) + (xy 103.621718 132.327446) (xy 103.604397 132.337446) (xy 104.179022 133.332726) (xy 104.395879 133.390832) (xy 104.582961 133.286368) + (xy 104.684635 133.213509) (xy 104.770142 133.122215) (xy 104.836194 133.015993) (xy 104.880255 132.898926) (xy 104.90063 132.775514) + (xy 104.896538 132.650496) (xy 104.868135 132.52868) (xy 104.816511 132.414745) (xy 104.556726 131.970928) (xy 104.339872 131.912822) + (xy 104.477352 131.833448) (xy 104.453226 131.791661) (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) + (xy 104.651604 131.677128) (xy 104.7368 131.616078) (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) + (xy 104.978308 131.126349) (xy 104.973731 130.986567) (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.898716 130.754892) + (xy 104.884253 130.722971) (xy 104.863839 130.694483) (xy 103.527189 128.379338) (xy 103.6686 128.379338) + ) + ) + (filled_polygon + (pts + (xy 193.6726 44.097402) (xy 193.696399 44.126401) (xy 193.812124 44.221374) (xy 193.944153 44.291946) (xy 194.087414 44.335403) + (xy 194.199067 44.3464) (xy 194.199076 44.3464) (xy 194.236399 44.350076) (xy 194.273722 44.3464) (xy 194.307217 44.3464) + (xy 194.290872 44.37698) (xy 194.250273 44.510816) (xy 194.236565 44.65) (xy 194.240001 44.684887) (xy 194.240001 44.886928) + (xy 193.887064 44.886928) (xy 193.901781 44.737501) (xy 193.884694 44.564011) (xy 193.834088 44.397187) (xy 193.75191 44.243442) + (xy 193.641317 44.108683) (xy 193.506558 43.99809) (xy 193.352813 43.915912) (xy 193.185989 43.865306) (xy 193.012499 43.848219) + (xy 192.839009 43.865306) (xy 192.672186 43.915912) (xy 192.51844 43.99809) (xy 192.417453 44.080968) (xy 191.174951 45.323471) + (xy 191.141184 45.351183) (xy 191.113471 45.384951) (xy 191.113468 45.384954) (xy 191.03059 45.485941) (xy 190.948412 45.639687) + (xy 190.897805 45.80651) (xy 190.880719 45.98) (xy 190.885001 46.023478) (xy 190.885 47.13703) (xy 190.880719 47.1805) + (xy 190.885 47.223969) (xy 190.885 47.223976) (xy 190.892782 47.302985) (xy 190.897805 47.35399) (xy 190.907204 47.384974) + (xy 190.948411 47.520812) (xy 191.030589 47.674558) (xy 191.141183 47.809317) (xy 191.174956 47.837034) (xy 191.74847 48.410549) + (xy 191.776183 48.444317) (xy 191.809951 48.47203) (xy 191.809953 48.472032) (xy 191.910941 48.554911) (xy 192.064686 48.637089) + (xy 192.202903 48.679017) (xy 192.23151 48.687695) (xy 192.361523 48.7005) (xy 192.361531 48.7005) (xy 192.405 48.704781) + (xy 192.448469 48.7005) (xy 193.027736 48.7005) (xy 193.048815 48.726185) (xy 193.145506 48.805537) (xy 193.25582 48.864502) + (xy 193.375518 48.900812) (xy 193.5 48.913072) (xy 194.24 48.913072) (xy 194.24 49.115123) (xy 194.236565 49.15) + (xy 194.250273 49.289184) (xy 194.290872 49.42302) (xy 194.3568 49.546363) (xy 194.445525 49.654475) (xy 194.528097 49.72224) + (xy 194.553637 49.7432) (xy 194.67698 49.809128) (xy 194.810816 49.849727) (xy 194.95 49.863435) (xy 194.984877 49.86) + (xy 195.815858 49.86) (xy 195.428175 50.020583) (xy 194.988412 50.314424) (xy 194.614424 50.688412) (xy 194.320583 51.128175) + (xy 194.118183 51.616814) (xy 194.015 52.135551) (xy 194.015 52.664449) (xy 194.118183 53.183186) (xy 194.123749 53.196623) + (xy 193.901302 53.047989) (xy 193.592012 52.919877) (xy 193.627932 52.833158) (xy 193.685 52.54626) (xy 193.685 52.25374) + (xy 193.627932 51.966842) (xy 193.51599 51.696589) (xy 193.353475 51.453368) (xy 193.146632 51.246525) (xy 192.903411 51.08401) + (xy 192.633158 50.972068) (xy 192.34626 50.915) (xy 192.176697 50.915) (xy 192.082327 50.875911) (xy 191.776109 50.815) + (xy 191.463891 50.815) (xy 191.157673 50.875911) (xy 190.869221 50.995391) (xy 190.609621 51.16885) (xy 190.38885 51.389621) + (xy 190.215391 51.649221) (xy 190.095911 51.937673) (xy 190.035 52.243891) (xy 190.035 47.812322) (xy 190.038676 47.774999) + (xy 190.035 47.737676) (xy 190.035 47.737667) (xy 190.024003 47.626014) (xy 189.980546 47.482753) (xy 189.909974 47.350724) + (xy 189.815001 47.234999) (xy 189.786003 47.211201) (xy 188.782879 46.208077) (xy 188.739967 46.104479) (xy 188.648587 45.967719) + (xy 188.532281 45.851413) (xy 188.395521 45.760033) (xy 188.24356 45.697089) (xy 188.08224 45.665) (xy 187.91776 45.665) + (xy 187.75644 45.697089) (xy 187.604479 45.760033) (xy 187.467719 45.851413) (xy 187.351413 45.967719) (xy 187.260033 46.104479) + (xy 187.197089 46.25644) (xy 187.165 46.41776) (xy 187.165 46.58224) (xy 187.197089 46.74356) (xy 187.260033 46.895521) + (xy 187.351413 47.032281) (xy 187.467719 47.148587) (xy 187.5251 47.186928) (xy 187.525 47.186928) (xy 187.400518 47.199188) + (xy 187.28082 47.235498) (xy 187.170506 47.294463) (xy 187.073815 47.373815) (xy 186.994463 47.470506) (xy 186.935498 47.58082) + (xy 186.899188 47.700518) (xy 186.886928 47.825) (xy 186.886928 49.125) (xy 186.899188 49.249482) (xy 186.935498 49.36918) + (xy 186.994463 49.479494) (xy 187.073815 49.576185) (xy 187.167863 49.653368) (xy 187.165 49.66776) (xy 187.165 49.83224) + (xy 187.197089 49.99356) (xy 187.260033 50.145521) (xy 187.329844 50.25) (xy 187.260033 50.354479) (xy 187.197089 50.50644) + (xy 187.165 50.66776) (xy 187.165 50.83224) (xy 187.167863 50.846632) (xy 187.073815 50.923815) (xy 186.994463 51.020506) + (xy 186.935498 51.13082) (xy 186.899188 51.250518) (xy 186.886928 51.375) (xy 186.886928 52.675) (xy 186.899188 52.799482) + (xy 186.935498 52.91918) (xy 186.994463 53.029494) (xy 187.073815 53.126185) (xy 187.170506 53.205537) (xy 187.28082 53.264502) + (xy 187.400518 53.300812) (xy 187.525 53.313072) (xy 188.475 53.313072) (xy 188.515 53.309132) (xy 188.515 56.902843) + (xy 188.472089 57.00644) (xy 188.44 57.16776) (xy 188.44 57.33224) (xy 188.472089 57.49356) (xy 188.535033 57.645521) + (xy 188.626413 57.782281) (xy 188.742719 57.898587) (xy 188.879479 57.989967) (xy 189.03144 58.052911) (xy 189.19276 58.085) + (xy 189.211928 58.085) (xy 189.211928 58.52) (xy 189.224188 58.644482) (xy 189.260498 58.76418) (xy 189.319463 58.874494) + (xy 189.398815 58.971185) (xy 189.495506 59.050537) (xy 189.60582 59.109502) (xy 189.725518 59.145812) (xy 189.85 59.158072) + (xy 192.15 59.158072) (xy 192.274482 59.145812) (xy 192.39418 59.109502) (xy 192.504494 59.050537) (xy 192.601185 58.971185) + (xy 192.615002 58.954348) (xy 192.799017 59.138363) (xy 193.148698 59.372012) (xy 193.433546 59.49) (xy 193.414465 59.49) + (xy 193.370999 59.485719) (xy 193.327533 59.49) (xy 193.327523 59.49) (xy 193.19751 59.502805) (xy 193.030687 59.553411) + (xy 192.876941 59.635589) (xy 192.86837 59.642623) (xy 192.775953 59.718468) (xy 192.775951 59.71847) (xy 192.742183 59.746183) + (xy 192.71447 59.779951) (xy 191.936956 60.557466) (xy 191.903183 60.585183) (xy 191.792589 60.719942) (xy 191.710411 60.873688) + (xy 191.679458 60.975724) (xy 191.67674 60.984684) (xy 191.598587 60.867719) (xy 191.482281 60.751413) (xy 191.345521 60.660033) + (xy 191.19356 60.597089) (xy 191.03224 60.565) (xy 190.86776 60.565) (xy 190.70644 60.597089) (xy 190.554479 60.660033) + (xy 190.417719 60.751413) (xy 190.301413 60.867719) (xy 190.210033 61.004479) (xy 190.147089 61.15644) (xy 190.115 61.31776) + (xy 190.115 61.48224) (xy 190.147089 61.64356) (xy 190.210033 61.795521) (xy 190.301413 61.932281) (xy 190.417719 62.048587) + (xy 190.554479 62.139967) (xy 190.658077 62.182879) (xy 191.286362 62.811164) (xy 191.23144 62.822089) (xy 191.127843 62.865) + (xy 189.623613 62.865) (xy 189.580372 62.847089) (xy 189.419052 62.815) (xy 189.254572 62.815) (xy 189.093252 62.847089) + (xy 188.941291 62.910033) (xy 188.804531 63.001413) (xy 188.688225 63.117719) (xy 188.596845 63.254479) (xy 188.533901 63.40644) + (xy 188.501812 63.56776) (xy 188.501812 63.711928) (xy 187.775 63.711928) (xy 187.650518 63.724188) (xy 187.53082 63.760498) + (xy 187.420506 63.819463) (xy 187.323815 63.898815) (xy 187.244463 63.995506) (xy 187.185498 64.10582) (xy 187.149188 64.225518) + (xy 187.136928 64.35) (xy 187.136928 65.65) (xy 187.149188 65.774482) (xy 187.185498 65.89418) (xy 187.244463 66.004494) + (xy 187.323815 66.101185) (xy 187.420506 66.180537) (xy 187.53082 66.239502) (xy 187.650518 66.275812) (xy 187.775 66.288072) + (xy 188.725 66.288072) (xy 188.74 66.286595) (xy 188.74 66.823162) (xy 188.645521 66.760033) (xy 188.49356 66.697089) + (xy 188.33224 66.665) (xy 188.16776 66.665) (xy 188.00644 66.697089) (xy 187.854479 66.760033) (xy 187.717719 66.851413) + (xy 187.601413 66.967719) (xy 187.510033 67.104479) (xy 187.447089 67.25644) (xy 187.425095 67.36701) (xy 187.420506 67.369463) + (xy 187.323815 67.448815) (xy 187.244463 67.545506) (xy 187.185498 67.65582) (xy 187.149188 67.775518) (xy 187.136928 67.9) + (xy 187.136928 69.2) (xy 187.149188 69.324482) (xy 187.185498 69.44418) (xy 187.244463 69.554494) (xy 187.323815 69.651185) + (xy 187.420506 69.730537) (xy 187.53082 69.789502) (xy 187.650518 69.825812) (xy 187.775 69.838072) (xy 188.725 69.838072) + (xy 188.849482 69.825812) (xy 188.96918 69.789502) (xy 189.079494 69.730537) (xy 189.176185 69.651185) (xy 189.255537 69.554494) + (xy 189.29 69.490018) (xy 189.29 74.182678) (xy 189.286324 74.22) (xy 189.29 74.257322) (xy 189.29 74.257332) + (xy 189.300997 74.368985) (xy 189.327486 74.456308) (xy 189.344454 74.512246) (xy 189.415026 74.644276) (xy 189.438204 74.672518) + (xy 189.509999 74.760001) (xy 189.539002 74.783804) (xy 189.592706 74.837507) (xy 189.495506 74.889463) (xy 189.398815 74.968815) + (xy 189.319463 75.065506) (xy 189.260498 75.17582) (xy 189.224188 75.295518) (xy 189.211928 75.42) (xy 189.211928 77.42) + (xy 189.224188 77.544482) (xy 189.260498 77.66418) (xy 189.319463 77.774494) (xy 189.398815 77.871185) (xy 189.495506 77.950537) + (xy 189.60582 78.009502) (xy 189.725518 78.045812) (xy 189.85 78.058072) (xy 190.030084 78.058072) (xy 190.047089 78.14356) + (xy 190.110033 78.295521) (xy 190.201413 78.432281) (xy 190.317719 78.548587) (xy 190.454479 78.639967) (xy 190.60644 78.702911) + (xy 190.76776 78.735) (xy 190.93224 78.735) (xy 191.09356 78.702911) (xy 191.245521 78.639967) (xy 191.382281 78.548587) + (xy 191.498587 78.432281) (xy 191.589967 78.295521) (xy 191.652911 78.14356) (xy 191.669916 78.058072) (xy 192.15 78.058072) + (xy 192.274482 78.045812) (xy 192.39418 78.009502) (xy 192.504494 77.950537) (xy 192.601185 77.871185) (xy 192.615002 77.854348) + (xy 192.799017 78.038363) (xy 193.148698 78.272012) (xy 193.537244 78.432953) (xy 193.833347 78.491852) (xy 193.308078 79.017121) + (xy 193.204479 79.060033) (xy 193.067719 79.151413) (xy 192.951413 79.267719) (xy 192.860033 79.404479) (xy 192.797089 79.55644) + (xy 192.765 79.71776) (xy 192.765 79.88224) (xy 192.797089 80.04356) (xy 192.860033 80.195521) (xy 192.951413 80.332281) + (xy 193.067719 80.448587) (xy 193.204479 80.539967) (xy 193.35644 80.602911) (xy 193.51776 80.635) (xy 193.68224 80.635) + (xy 193.84356 80.602911) (xy 193.995521 80.539967) (xy 194.132281 80.448587) (xy 194.248587 80.332281) (xy 194.339967 80.195521) + (xy 194.382879 80.091922) (xy 196.496005 77.978797) (xy 196.525002 77.955) (xy 196.619975 77.839275) (xy 196.690547 77.707246) + (xy 196.734004 77.563985) (xy 196.745001 77.452332) (xy 196.745001 77.452324) (xy 196.748677 77.414999) (xy 196.745001 77.377674) + (xy 196.745001 75.978798) (xy 197.342958 75.380841) (xy 197.187047 75.757244) (xy 197.105 76.169721) (xy 197.105 76.590279) + (xy 197.187047 77.002756) (xy 197.347988 77.391302) (xy 197.581637 77.740983) (xy 197.879017 78.038363) (xy 198.228698 78.272012) + (xy 198.617244 78.432953) (xy 199.029721 78.515) (xy 199.450279 78.515) (xy 199.862756 78.432953) (xy 200.251302 78.272012) + (xy 200.600983 78.038363) (xy 200.898363 77.740983) (xy 201.132012 77.391302) (xy 201.292953 77.002756) (xy 201.375 76.590279) + (xy 201.375 76.169721) (xy 201.305698 75.821318) (xy 201.521302 75.732012) (xy 201.870983 75.498363) (xy 202.071475 75.297871) + (xy 202.098815 75.331185) (xy 202.195506 75.410537) (xy 202.30582 75.469502) (xy 202.425518 75.505812) (xy 202.55 75.518072) + (xy 204.85 75.518072) (xy 204.974482 75.505812) (xy 205.09418 75.469502) (xy 205.204494 75.410537) (xy 205.29 75.340364) + (xy 205.290001 85.881514) (xy 205.29 85.881524) (xy 205.29 85.881531) (xy 205.285719 85.925) (xy 205.29 85.96847) + (xy 205.290001 86.881515) (xy 205.29 86.881524) (xy 205.29 87.114999) (xy 204.035 87.114999) (xy 204.035 87.10326) + (xy 204.002911 86.94194) (xy 203.96 86.838343) (xy 203.96 80.387322) (xy 203.963676 80.349999) (xy 203.96 80.312676) + (xy 203.96 80.312667) (xy 203.949003 80.201014) (xy 203.905546 80.057753) (xy 203.890843 80.030246) (xy 203.834974 79.925723) + (xy 203.763799 79.838997) (xy 203.740001 79.809999) (xy 203.711004 79.786202) (xy 202.282879 78.358078) (xy 202.239967 78.254479) + (xy 202.148587 78.117719) (xy 202.032281 78.001413) (xy 201.895521 77.910033) (xy 201.74356 77.847089) (xy 201.58224 77.815) + (xy 201.41776 77.815) (xy 201.25644 77.847089) (xy 201.104479 77.910033) (xy 200.967719 78.001413) (xy 200.851413 78.117719) + (xy 200.760033 78.254479) (xy 200.697089 78.40644) (xy 200.665 78.56776) (xy 200.665 78.73224) (xy 200.697089 78.89356) + (xy 200.760033 79.045521) (xy 200.851413 79.182281) (xy 200.967719 79.298587) (xy 201.104479 79.389967) (xy 201.208078 79.432879) + (xy 202.44 80.664802) (xy 202.440001 86.838341) (xy 202.397089 86.94194) (xy 202.365 87.10326) (xy 202.365 87.114999) + (xy 200.575616 87.114999) (xy 200.573911 87.106429) (xy 200.510967 86.954468) (xy 200.419587 86.817708) (xy 200.385838 86.783959) + (xy 200.430537 86.729494) (xy 200.489502 86.61918) (xy 200.525812 86.499482) (xy 200.538072 86.375) (xy 200.538072 85.81173) + (xy 200.934601 85.415201) (xy 200.995521 85.389967) (xy 201.132281 85.298587) (xy 201.248587 85.182281) (xy 201.339967 85.045521) + (xy 201.402911 84.89356) (xy 201.435 84.73224) (xy 201.435 84.56776) (xy 201.402911 84.40644) (xy 201.339967 84.254479) + (xy 201.248587 84.117719) (xy 201.132281 84.001413) (xy 200.995521 83.910033) (xy 200.84356 83.847089) (xy 200.68224 83.815) + (xy 200.535348 83.815) (xy 200.538072 83.625) (xy 200.525812 83.500518) (xy 200.489502 83.38082) (xy 200.430537 83.270506) + (xy 200.351185 83.173815) (xy 200.254494 83.094463) (xy 200.14418 83.035498) (xy 200.024482 82.999188) (xy 199.9 82.986928) + (xy 199.38575 82.99) (xy 199.227002 83.148748) (xy 199.227002 82.99) (xy 199.16 82.99) (xy 199.16 82.784877) + (xy 199.163435 82.75) (xy 199.149727 82.610816) (xy 199.109128 82.47698) (xy 199.0432 82.353637) (xy 198.954475 82.245525) + (xy 198.846363 82.1568) (xy 198.72302 82.090872) (xy 198.589184 82.050273) (xy 198.484877 82.04) (xy 198.45 82.036565) + (xy 198.415123 82.04) (xy 194.984877 82.04) (xy 194.95 82.036565) (xy 194.915123 82.04) (xy 194.810816 82.050273) + (xy 194.67698 82.090872) (xy 194.553637 82.1568) (xy 194.445525 82.245525) (xy 194.3568 82.353637) (xy 194.290872 82.47698) + (xy 194.250273 82.610816) (xy 194.236565 82.75) (xy 194.240001 82.784887) (xy 194.240001 82.986928) (xy 193.5 82.986928) + (xy 193.375518 82.999188) (xy 193.25582 83.035498) (xy 193.145506 83.094463) (xy 193.048815 83.173815) (xy 192.969463 83.270506) + (xy 192.918954 83.365) (xy 192.762322 83.365) (xy 192.724999 83.361324) (xy 192.687676 83.365) (xy 192.687667 83.365) + (xy 192.576014 83.375997) (xy 192.432753 83.419454) (xy 192.300724 83.490026) (xy 192.184999 83.584999) (xy 192.161201 83.613997) + (xy 191.458077 84.317121) (xy 191.354479 84.360033) (xy 191.217719 84.451413) (xy 191.101413 84.567719) (xy 191.010033 84.704479) + (xy 190.947089 84.85644) (xy 190.915 85.01776) (xy 190.915 85.18224) (xy 190.947089 85.34356) (xy 191.010033 85.495521) + (xy 191.101413 85.632281) (xy 191.217719 85.748587) (xy 191.354479 85.839967) (xy 191.50644 85.902911) (xy 191.66776 85.935) + (xy 191.83224 85.935) (xy 191.99356 85.902911) (xy 192.145521 85.839967) (xy 192.261137 85.762715) (xy 192.861928 86.363507) + (xy 192.861928 86.375) (xy 192.874188 86.499482) (xy 192.910498 86.61918) (xy 192.969463 86.729494) (xy 193.048815 86.826185) + (xy 193.145506 86.905537) (xy 193.25582 86.964502) (xy 193.375518 87.000812) (xy 193.415001 87.004701) (xy 193.415001 87.406521) + (xy 193.410719 87.45) (xy 193.427805 87.62349) (xy 193.478412 87.790313) (xy 193.56059 87.944059) (xy 193.643468 88.045046) + (xy 193.643471 88.045049) (xy 193.671184 88.078817) (xy 193.704952 88.10653) (xy 194.193465 88.595043) (xy 194.221182 88.628816) + (xy 194.35594 88.73941) (xy 194.509686 88.821588) (xy 194.578341 88.842414) (xy 194.320583 89.228175) (xy 194.118183 89.716814) + (xy 194.015 90.235551) (xy 194.015 90.764449) (xy 194.118183 91.283186) (xy 194.123749 91.296623) (xy 193.901302 91.147989) + (xy 193.592012 91.019877) (xy 193.627932 90.933158) (xy 193.685 90.64626) (xy 193.685 90.35374) (xy 193.627932 90.066842) + (xy 193.51599 89.796589) (xy 193.353475 89.553368) (xy 193.146632 89.346525) (xy 192.903411 89.18401) (xy 192.633158 89.072068) + (xy 192.34626 89.015) (xy 192.176697 89.015) (xy 192.082327 88.975911) (xy 191.776109 88.915) (xy 191.463891 88.915) + (xy 191.157673 88.975911) (xy 190.869221 89.095391) (xy 190.609621 89.26885) (xy 190.38885 89.489621) (xy 190.215391 89.749221) + (xy 190.095911 90.037673) (xy 190.035 90.343891) (xy 190.035 90.656109) (xy 190.095911 90.962327) (xy 190.215391 91.250779) + (xy 190.38885 91.510379) (xy 190.609621 91.73115) (xy 190.869221 91.904609) (xy 191.035016 91.973283) (xy 190.997988 92.028699) + (xy 190.837047 92.417245) (xy 190.755 92.829722) (xy 190.755 93.25028) (xy 190.837047 93.662757) (xy 190.969252 93.981928) + (xy 189.85 93.981928) (xy 189.725518 93.994188) (xy 189.60582 94.030498) (xy 189.495506 94.089463) (xy 189.398815 94.168815) + (xy 189.319463 94.265506) (xy 189.260498 94.37582) (xy 189.224188 94.495518) (xy 189.211928 94.62) (xy 189.211928 96.62) + (xy 189.224188 96.744482) (xy 189.260498 96.86418) (xy 189.319463 96.974494) (xy 189.398815 97.071185) (xy 189.495506 97.150537) + (xy 189.60582 97.209502) (xy 189.725518 97.245812) (xy 189.85 97.258072) (xy 191.61327 97.258072) (xy 192.329055 97.973858) + (xy 192.352849 98.002851) (xy 192.381842 98.026645) (xy 192.381846 98.026649) (xy 192.444506 98.078072) (xy 192.468574 98.097824) + (xy 192.600603 98.168396) (xy 192.743864 98.211853) (xy 192.855517 98.22285) (xy 192.855526 98.22285) (xy 192.892849 98.226526) + (xy 192.930172 98.22285) (xy 195.152346 98.22285) (xy 193.788998 99.586199) (xy 193.76 99.609997) (xy 193.736202 99.638995) + (xy 193.736201 99.638996) (xy 193.665026 99.725722) (xy 193.594454 99.857752) (xy 193.566692 99.949275) (xy 193.550998 100.001012) + (xy 193.542231 100.090026) (xy 193.536324 100.149998) (xy 193.540001 100.18733) (xy 193.54 101.986928) (xy 193.5 101.986928) + (xy 193.375518 101.999188) (xy 193.25582 102.035498) (xy 193.145506 102.094463) (xy 193.048815 102.173815) (xy 192.969463 102.270506) + (xy 192.910498 102.38082) (xy 192.874188 102.500518) (xy 192.861928 102.625) (xy 192.861928 103.063271) (xy 192.742704 103.182494) + (xy 192.639106 103.225406) (xy 192.589831 103.25833) (xy 192.440313 103.178412) (xy 192.27349 103.127805) (xy 192.1 103.110719) + (xy 191.92651 103.127805) (xy 191.759687 103.178412) (xy 191.605941 103.26059) (xy 191.471183 103.371183) (xy 191.36059 103.505941) + (xy 191.278412 103.659687) (xy 191.227805 103.82651) (xy 191.210719 104) (xy 191.227805 104.17349) (xy 191.278412 104.340313) + (xy 191.36059 104.494059) (xy 191.443468 104.595046) (xy 192.31847 105.470049) (xy 192.346183 105.503817) (xy 192.379951 105.53153) + (xy 192.379953 105.531532) (xy 192.434029 105.575911) (xy 192.480941 105.614411) (xy 192.634687 105.696589) (xy 192.80151 105.747195) + (xy 192.931523 105.76) (xy 192.931531 105.76) (xy 192.975 105.764281) (xy 192.996291 105.762184) (xy 193.048815 105.826185) + (xy 193.145506 105.905537) (xy 193.25582 105.964502) (xy 193.375518 106.000812) (xy 193.5 106.013072) (xy 194.24 106.013072) + (xy 194.24 106.215123) (xy 194.236565 106.25) (xy 194.250273 106.389184) (xy 194.290872 106.52302) (xy 194.3568 106.646363) + (xy 194.445525 106.754475) (xy 194.540291 106.832247) (xy 194.553637 106.8432) (xy 194.67698 106.909128) (xy 194.810816 106.949727) + (xy 194.95 106.963435) (xy 194.984877 106.96) (xy 195.815858 106.96) (xy 195.428175 107.120583) (xy 194.988412 107.414424) + (xy 194.614424 107.788412) (xy 194.320583 108.228175) (xy 194.118183 108.716814) (xy 194.015 109.235551) (xy 194.015 109.764449) + (xy 194.118183 110.283186) (xy 194.123749 110.296623) (xy 193.901302 110.147989) (xy 193.592012 110.019877) (xy 193.627932 109.933158) + (xy 193.685 109.64626) (xy 193.685 109.35374) (xy 193.627932 109.066842) (xy 193.51599 108.796589) (xy 193.353475 108.553368) + (xy 193.146632 108.346525) (xy 192.903411 108.18401) (xy 192.633158 108.072068) (xy 192.34626 108.015) (xy 192.176697 108.015) + (xy 192.082327 107.975911) (xy 191.776109 107.915) (xy 191.463891 107.915) (xy 191.157673 107.975911) (xy 190.869221 108.095391) + (xy 190.609621 108.26885) (xy 190.38885 108.489621) (xy 190.215391 108.749221) (xy 190.095911 109.037673) (xy 190.035 109.343891) + (xy 190.035 109.656109) (xy 190.095911 109.962327) (xy 190.215391 110.250779) (xy 190.38885 110.510379) (xy 190.609621 110.73115) + (xy 190.869221 110.904609) (xy 191.035016 110.973283) (xy 190.997988 111.028699) (xy 190.837047 111.417245) (xy 190.755 111.829722) + (xy 190.755 112.25028) (xy 190.837047 112.662757) (xy 190.969252 112.981928) (xy 189.85 112.981928) (xy 189.725518 112.994188) + (xy 189.60582 113.030498) (xy 189.495506 113.089463) (xy 189.436818 113.137627) (xy 189.395521 113.110033) (xy 189.291922 113.067121) + (xy 189.2915 113.066699) (xy 189.2915 109.725846) (xy 189.329494 109.705537) (xy 189.426185 109.626185) (xy 189.505537 109.529494) + (xy 189.564502 109.41918) (xy 189.600812 109.299482) (xy 189.613072 109.175) (xy 189.613072 107.875) (xy 189.600812 107.750518) + (xy 189.564502 107.63082) (xy 189.505537 107.520506) (xy 189.426185 107.423815) (xy 189.329494 107.344463) (xy 189.21918 107.285498) + (xy 189.099482 107.249188) (xy 188.975 107.236928) (xy 188.025 107.236928) (xy 187.900518 107.249188) (xy 187.78082 107.285498) + (xy 187.670506 107.344463) (xy 187.573815 107.423815) (xy 187.494463 107.520506) (xy 187.435498 107.63082) (xy 187.399188 107.750518) + (xy 187.386928 107.875) (xy 187.386928 109.175) (xy 187.399188 109.299482) (xy 187.435498 109.41918) (xy 187.494463 109.529494) + (xy 187.573815 109.626185) (xy 187.670506 109.705537) (xy 187.771501 109.759521) (xy 187.7715 113.344177) (xy 187.767824 113.3815) + (xy 187.7715 113.418822) (xy 187.7715 113.418832) (xy 187.782497 113.530485) (xy 187.813746 113.633501) (xy 187.825954 113.673746) + (xy 187.896526 113.805776) (xy 187.92327 113.838363) (xy 187.991499 113.921501) (xy 188.020503 113.945304) (xy 188.217121 114.141922) + (xy 188.240001 114.197159) (xy 188.24 115.212677) (xy 188.236324 115.25) (xy 188.24 115.287322) (xy 188.24 115.287332) + (xy 188.250997 115.398985) (xy 188.290959 115.530725) (xy 188.294454 115.542246) (xy 188.365026 115.674276) (xy 188.397475 115.713815) + (xy 188.459999 115.790001) (xy 188.489003 115.813804) (xy 190.440198 117.765) (xy 189.906523 117.765) (xy 189.77651 117.777805) + (xy 189.609687 117.828411) (xy 189.455941 117.910589) (xy 189.321183 118.021183) (xy 189.210589 118.155941) (xy 189.128411 118.309687) + (xy 189.077805 118.47651) (xy 189.060718 118.65) (xy 189.077805 118.82349) (xy 189.117654 118.954853) (xy 189.095304 118.932503) + (xy 189.071501 118.903499) (xy 188.955776 118.808526) (xy 188.855995 118.755191) (xy 188.839502 118.70082) (xy 188.780537 118.590506) + (xy 188.701185 118.493815) (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) (xy 188.25 118.306928) + (xy 186.25 118.306928) (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) (xy 185.798815 118.493815) + (xy 185.719463 118.590506) (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) (xy 185.611928 119.945) + (xy 185.624188 120.069482) (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) (xy 185.719463 120.340506) + (xy 185.660498 120.45082) (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.260001) (xy 184.488072 121.260001) + (xy 184.488072 120.695) (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) (xy 184.363708 120.32) + (xy 184.380537 120.299494) (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) (xy 184.485 119.73075) + (xy 184.32625 119.572) (xy 182.977 119.572) (xy 182.977 119.592) (xy 182.723 119.592) (xy 182.723 119.572) + (xy 182.703 119.572) (xy 182.703 119.318) (xy 182.723 119.318) (xy 182.723 119.298) (xy 182.977 119.298) + (xy 182.977 119.318) (xy 184.32625 119.318) (xy 184.485 119.15925) (xy 184.488072 118.945) (xy 184.475812 118.820518) + (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) (xy 184.379711 118.35376) + (xy 184.4118 118.19244) (xy 184.4118 118.02796) (xy 184.379711 117.86664) (xy 184.316767 117.714679) (xy 184.225387 117.577919) + (xy 184.109081 117.461613) (xy 183.972321 117.370233) (xy 183.82036 117.307289) (xy 183.65904 117.2752) (xy 183.49456 117.2752) + (xy 183.33324 117.307289) (xy 183.181279 117.370233) (xy 183.044519 117.461613) (xy 183.003532 117.5026) (xy 182.120557 117.5026) + (xy 182.01696 117.459689) (xy 181.85564 117.4276) (xy 181.69116 117.4276) (xy 181.52984 117.459689) (xy 181.377879 117.522633) + (xy 181.299353 117.575103) (xy 181.27625 117.552) (xy 180.127 117.552) (xy 180.127 117.572) (xy 180.0588 117.572) + (xy 180.0588 117.278) (xy 180.127 117.278) (xy 180.127 117.298) (xy 181.27625 117.298) (xy 181.435 117.13925) + (xy 181.438072 116.925) (xy 181.425812 116.800518) (xy 181.389502 116.68082) (xy 181.330537 116.570506) (xy 181.251185 116.473815) + (xy 181.154494 116.394463) (xy 181.04418 116.335498) (xy 180.924482 116.299188) (xy 180.8 116.286928) (xy 180.28575 116.29) + (xy 180.127002 116.448748) (xy 180.127002 116.29) (xy 180.0588 116.29) (xy 180.0588 116.070077) (xy 180.062235 116.0352) + (xy 180.048527 115.896016) (xy 180.007928 115.76218) (xy 179.942 115.638837) (xy 179.853275 115.530725) (xy 179.745163 115.442) + (xy 179.62182 115.376072) (xy 179.487984 115.335473) (xy 179.383677 115.3252) (xy 179.3488 115.321765) (xy 179.313923 115.3252) + (xy 175.883677 115.3252) (xy 175.863196 115.323183) (xy 175.848587 115.301319) (xy 175.732281 115.185013) (xy 175.595521 115.093633) + (xy 175.44356 115.030689) (xy 175.28224 114.9986) (xy 175.11776 114.9986) (xy 174.95644 115.030689) (xy 174.804479 115.093633) + (xy 174.667719 115.185013) (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) (xy 174.365 115.75136) + (xy 174.365 115.91584) (xy 174.397089 116.07716) (xy 174.44 116.180757) (xy 174.44 116.286928) (xy 174.4 116.286928) + (xy 174.275518 116.299188) (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.869463 116.570506) + (xy 173.810498 116.68082) (xy 173.774188 116.800518) (xy 173.761928 116.925) (xy 173.761928 117.453) (xy 173.74096 117.453) + (xy 173.6168 117.477697) (xy 173.6168 117.31676) (xy 173.584711 117.15544) (xy 173.521767 117.003479) (xy 173.430387 116.866719) + (xy 173.314081 116.750413) (xy 173.177321 116.659033) (xy 173.02536 116.596089) (xy 172.86404 116.564) (xy 172.729 116.564) + (xy 172.729 115.612557) (xy 172.771911 115.50896) (xy 172.804 115.34764) (xy 172.804 115.18316) (xy 172.771911 115.02184) + (xy 172.708967 114.869879) (xy 172.617587 114.733119) (xy 172.501281 114.616813) (xy 172.364521 114.525433) (xy 172.21256 114.462489) + (xy 172.05124 114.4304) (xy 171.88676 114.4304) (xy 171.72544 114.462489) (xy 171.573479 114.525433) (xy 171.436719 114.616813) + (xy 171.320413 114.733119) (xy 171.229033 114.869879) (xy 171.166089 115.02184) (xy 171.134 115.18316) (xy 171.134 115.34764) + (xy 171.166089 115.50896) (xy 171.209 115.612557) (xy 171.209001 119.921198) (xy 167.388072 123.742128) (xy 167.388072 122.87) + (xy 167.375812 122.745518) (xy 167.339502 122.62582) (xy 167.280537 122.515506) (xy 167.201185 122.418815) (xy 167.104494 122.339463) + (xy 166.99418 122.280498) (xy 166.874482 122.244188) (xy 166.75 122.231928) (xy 164.956887 122.231928) (xy 165.084609 122.040779) + (xy 165.204089 121.752327) (xy 165.265 121.446109) (xy 165.265 121.133891) (xy 165.204089 120.827673) (xy 165.084609 120.539221) + (xy 164.91115 120.279621) (xy 164.690379 120.05885) (xy 164.430779 119.885391) (xy 164.142327 119.765911) (xy 163.836109 119.705) + (xy 163.523891 119.705) (xy 163.217673 119.765911) (xy 163.123303 119.805) (xy 162.95374 119.805) (xy 162.666842 119.862068) + (xy 162.396589 119.97401) (xy 162.153368 120.136525) (xy 161.946525 120.343368) (xy 161.78401 120.586589) (xy 161.672068 120.856842) + (xy 161.615 121.14374) (xy 161.615 121.43626) (xy 161.672068 121.723158) (xy 161.707988 121.809876) (xy 161.398698 121.937988) + (xy 161.176252 122.086622) (xy 161.181817 122.073186) (xy 161.285 121.554449) (xy 161.285 121.025551) (xy 161.181817 120.506814) + (xy 160.979417 120.018175) (xy 160.750114 119.674999) (xy 160.911927 119.674999) (xy 160.949249 119.678675) (xy 160.986571 119.674999) + (xy 160.986582 119.674999) (xy 161.098235 119.664002) (xy 161.241496 119.620545) (xy 161.373525 119.549973) (xy 161.48925 119.455) + (xy 161.513053 119.425996) (xy 166.460999 114.478051) (xy 166.489997 114.454253) (xy 166.58497 114.338528) (xy 166.655542 114.206499) + (xy 166.698999 114.063237) (xy 166.706509 113.986984) (xy 166.752907 113.87497) (xy 166.754612 113.8664) (xy 183.798742 113.8664) + (xy 183.836064 113.870076) (xy 183.873386 113.8664) (xy 183.873397 113.8664) (xy 183.98505 113.855403) (xy 184.128311 113.811946) + (xy 184.26034 113.741374) (xy 184.376065 113.646401) (xy 184.399867 113.617398) (xy 184.925455 113.09181) (xy 185.029053 113.048899) + (xy 185.165813 112.957519) (xy 185.282119 112.841213) (xy 185.373499 112.704453) (xy 185.436443 112.552492) (xy 185.468532 112.391172) + (xy 185.468532 112.226692) (xy 185.436443 112.065372) (xy 185.373499 111.913411) (xy 185.282119 111.776651) (xy 185.165813 111.660345) + (xy 185.029053 111.568965) (xy 184.877092 111.506021) (xy 184.715772 111.473932) (xy 184.551292 111.473932) (xy 184.389972 111.506021) + (xy 184.238011 111.568965) (xy 184.101251 111.660345) (xy 183.984945 111.776651) (xy 183.893565 111.913411) (xy 183.850654 112.017009) + (xy 183.521263 112.3464) (xy 182.378401 112.3464) (xy 185.111003 109.613799) (xy 185.140001 109.590001) (xy 185.181036 109.54) + (xy 185.234974 109.474277) (xy 185.305546 109.342247) (xy 185.320315 109.29356) (xy 185.349003 109.198986) (xy 185.36 109.087333) + (xy 185.36 109.087324) (xy 185.363676 109.050001) (xy 185.36 109.012678) (xy 185.36 108.918072) (xy 185.75 108.918072) + (xy 185.874482 108.905812) (xy 185.99418 108.869502) (xy 186.104494 108.810537) (xy 186.201185 108.731185) (xy 186.280537 108.634494) + (xy 186.339502 108.52418) (xy 186.375812 108.404482) (xy 186.388072 108.28) (xy 186.388072 106.28) (xy 186.375812 106.155518) + (xy 186.339502 106.03582) (xy 186.280537 105.925506) (xy 186.201185 105.828815) (xy 186.104494 105.749463) (xy 185.99418 105.690498) + (xy 185.874482 105.654188) (xy 185.75 105.641928) (xy 183.956887 105.641928) (xy 184.084609 105.450779) (xy 184.204089 105.162327) + (xy 184.265 104.856109) (xy 184.265 104.543891) (xy 184.22146 104.325) (xy 187.386928 104.325) (xy 187.386928 105.625) + (xy 187.399188 105.749482) (xy 187.435498 105.86918) (xy 187.494463 105.979494) (xy 187.573815 106.076185) (xy 187.670506 106.155537) + (xy 187.78082 106.214502) (xy 187.900518 106.250812) (xy 188.025 106.263072) (xy 188.650908 106.263072) (xy 188.738913 106.394781) + (xy 188.855219 106.511087) (xy 188.991979 106.602467) (xy 189.14394 106.665411) (xy 189.30526 106.6975) (xy 189.46974 106.6975) + (xy 189.63106 106.665411) (xy 189.783021 106.602467) (xy 189.919781 106.511087) (xy 190.036087 106.394781) (xy 190.127467 106.258021) + (xy 190.190411 106.10606) (xy 190.2225 105.94474) (xy 190.2225 105.78026) (xy 190.190411 105.61894) (xy 190.127467 105.466979) + (xy 190.036087 105.330219) (xy 189.919781 105.213913) (xy 189.783021 105.122533) (xy 189.679423 105.079622) (xy 189.613072 105.01327) + (xy 189.613072 104.325) (xy 189.600812 104.200518) (xy 189.564502 104.08082) (xy 189.505537 103.970506) (xy 189.426185 103.873815) + (xy 189.329494 103.794463) (xy 189.21918 103.735498) (xy 189.099482 103.699188) (xy 188.975 103.686928) (xy 188.025 103.686928) + (xy 187.900518 103.699188) (xy 187.78082 103.735498) (xy 187.670506 103.794463) (xy 187.573815 103.873815) (xy 187.494463 103.970506) + (xy 187.435498 104.08082) (xy 187.399188 104.200518) (xy 187.386928 104.325) (xy 184.22146 104.325) (xy 184.204089 104.237673) + (xy 184.084609 103.949221) (xy 183.91115 103.689621) (xy 183.690379 103.46885) (xy 183.430779 103.295391) (xy 183.142327 103.175911) + (xy 182.836109 103.115) (xy 182.523891 103.115) (xy 182.217673 103.175911) (xy 182.123303 103.215) (xy 181.95374 103.215) + (xy 181.666842 103.272068) (xy 181.396589 103.38401) (xy 181.153368 103.546525) (xy 180.946525 103.753368) (xy 180.78401 103.996589) + (xy 180.672068 104.266842) (xy 180.615 104.55374) (xy 180.615 104.84626) (xy 180.672068 105.133158) (xy 180.707988 105.219876) + (xy 180.398698 105.347988) (xy 180.176252 105.496622) (xy 180.181817 105.483186) (xy 180.285 104.964449) (xy 180.285 104.435551) + (xy 180.181817 103.916814) (xy 179.979417 103.428175) (xy 179.685576 102.988412) (xy 179.311588 102.614424) (xy 178.871825 102.320583) + (xy 178.725564 102.26) (xy 179.315123 102.26) (xy 179.35 102.263435) (xy 179.384877 102.26) (xy 179.489184 102.249727) + (xy 179.62302 102.209128) (xy 179.746363 102.1432) (xy 179.854475 102.054475) (xy 179.9432 101.946363) (xy 180.009128 101.82302) + (xy 180.049727 101.689184) (xy 180.063435 101.55) (xy 180.06 101.515123) (xy 180.06 101.213072) (xy 180.8 101.213072) + (xy 180.924482 101.200812) (xy 181.04418 101.164502) (xy 181.154494 101.105537) (xy 181.251185 101.026185) (xy 181.330537 100.929494) + (xy 181.389502 100.81918) (xy 181.425812 100.699482) (xy 181.438072 100.575) (xy 181.438072 99.92573) (xy 181.761004 99.602798) + (xy 181.790001 99.579001) (xy 181.884974 99.463276) (xy 181.913356 99.410177) (xy 181.989967 99.295521) (xy 182.052911 99.14356) + (xy 182.085 98.98224) (xy 182.085 98.81776) (xy 182.052911 98.65644) (xy 181.989967 98.504479) (xy 181.898587 98.367719) + (xy 181.782281 98.251413) (xy 181.645521 98.160033) (xy 181.49356 98.097089) (xy 181.396473 98.077777) (xy 181.435 98.03925) + (xy 181.438072 97.825) (xy 181.425812 97.700518) (xy 181.389502 97.58082) (xy 181.330537 97.470506) (xy 181.251185 97.373815) + (xy 181.154494 97.294463) (xy 181.04418 97.235498) (xy 180.924482 97.199188) (xy 180.8 97.186928) (xy 180.28575 97.19) + (xy 180.127002 97.348748) (xy 180.127002 97.19) (xy 180.06 97.19) (xy 180.06 97.084877) (xy 180.063435 97.05) + (xy 180.049727 96.910816) (xy 180.009128 96.77698) (xy 179.9432 96.653637) (xy 179.854475 96.545525) (xy 179.746363 96.4568) + (xy 179.62302 96.390872) (xy 179.489184 96.350273) (xy 179.384877 96.34) (xy 179.35 96.336565) (xy 179.315123 96.34) + (xy 175.884877 96.34) (xy 175.85 96.336565) (xy 175.815123 96.34) (xy 175.710816 96.350273) (xy 175.57698 96.390872) + (xy 175.453637 96.4568) (xy 175.345525 96.545525) (xy 175.2568 96.653637) (xy 175.190872 96.77698) (xy 175.150273 96.910816) + (xy 175.136565 97.05) (xy 175.140001 97.084887) (xy 175.140001 97.186928) (xy 174.4 97.186928) (xy 174.275518 97.199188) + (xy 174.15582 97.235498) (xy 174.045506 97.294463) (xy 173.948815 97.373815) (xy 173.869463 97.470506) (xy 173.810498 97.58082) + (xy 173.798882 97.619111) (xy 173.797753 97.619454) (xy 173.665723 97.690026) (xy 173.59386 97.749003) (xy 173.549999 97.784999) + (xy 173.5262 97.813998) (xy 172.989002 98.351197) (xy 172.959999 98.374999) (xy 172.919797 98.423986) (xy 172.865026 98.490724) + (xy 172.814634 98.585) (xy 172.794454 98.622754) (xy 172.750997 98.766015) (xy 172.749669 98.779501) (xy 172.697089 98.90644) + (xy 172.665 99.06776) (xy 172.665 99.076799) (xy 172.659687 99.078411) (xy 172.505941 99.160589) (xy 172.371183 99.271183) + (xy 172.260589 99.405941) (xy 172.178411 99.559687) (xy 172.127805 99.72651) (xy 172.110718 99.9) (xy 172.127805 100.07349) + (xy 172.178411 100.240313) (xy 172.260589 100.394059) (xy 172.371183 100.528817) (xy 172.505941 100.639411) (xy 172.659687 100.721589) + (xy 172.82651 100.772195) (xy 172.956523 100.785) (xy 173.80013 100.785) (xy 173.810498 100.81918) (xy 173.869463 100.929494) + (xy 173.948815 101.026185) (xy 174.045506 101.105537) (xy 174.15582 101.164502) (xy 174.275518 101.200812) (xy 174.4 101.213072) + (xy 175.14 101.213072) (xy 175.14 101.515123) (xy 175.136565 101.55) (xy 175.150273 101.689184) (xy 175.190872 101.82302) + (xy 175.2568 101.946363) (xy 175.345525 102.054475) (xy 175.430471 102.124188) (xy 175.453637 102.1432) (xy 175.57698 102.209128) + (xy 175.710816 102.249727) (xy 175.85 102.263435) (xy 175.884877 102.26) (xy 176.474436 102.26) (xy 176.328175 102.320583) + (xy 175.888412 102.614424) (xy 175.514424 102.988412) (xy 175.220583 103.428175) (xy 175.018183 103.916814) (xy 174.915 104.435551) + (xy 174.915 104.964449) (xy 175.018183 105.483186) (xy 175.023749 105.496623) (xy 174.801302 105.347989) (xy 174.492012 105.219877) + (xy 174.527932 105.133158) (xy 174.585 104.84626) (xy 174.585 104.55374) (xy 174.527932 104.266842) (xy 174.41599 103.996589) + (xy 174.253475 103.753368) (xy 174.046632 103.546525) (xy 173.803411 103.38401) (xy 173.533158 103.272068) (xy 173.24626 103.215) + (xy 173.076697 103.215) (xy 172.982327 103.175911) (xy 172.676109 103.115) (xy 172.363891 103.115) (xy 172.057673 103.175911) + (xy 171.769221 103.295391) (xy 171.509621 103.46885) (xy 171.28885 103.689621) (xy 171.115391 103.949221) (xy 170.995911 104.237673) + (xy 170.935 104.543891) (xy 170.935 104.856109) (xy 170.995911 105.162327) (xy 171.115391 105.450779) (xy 171.28885 105.710379) + (xy 171.509621 105.93115) (xy 171.769221 106.104609) (xy 171.935016 106.173283) (xy 171.897988 106.228699) (xy 171.737047 106.617245) + (xy 171.655 107.029722) (xy 171.655 107.45028) (xy 171.737047 107.862757) (xy 171.869252 108.181928) (xy 170.75 108.181928) + (xy 170.625518 108.194188) (xy 170.50582 108.230498) (xy 170.395506 108.289463) (xy 170.336818 108.337627) (xy 170.295521 108.310033) + (xy 170.191923 108.267122) (xy 170.01 108.085199) (xy 170.01 105.142683) (xy 170.079494 105.105537) (xy 170.176185 105.026185) + (xy 170.255537 104.929494) (xy 170.314502 104.81918) (xy 170.350812 104.699482) (xy 170.363072 104.575) (xy 170.363072 103.275) + (xy 170.350812 103.150518) (xy 170.314502 103.03082) (xy 170.255537 102.920506) (xy 170.176185 102.823815) (xy 170.079494 102.744463) + (xy 169.96918 102.685498) (xy 169.849482 102.649188) (xy 169.725 102.636928) (xy 168.775 102.636928) (xy 168.650518 102.649188) + (xy 168.53082 102.685498) (xy 168.420506 102.744463) (xy 168.323815 102.823815) (xy 168.244463 102.920506) (xy 168.185498 103.03082) + (xy 168.149188 103.150518) (xy 168.136928 103.275) (xy 168.136928 104.575) (xy 168.149188 104.699482) (xy 168.185498 104.81918) + (xy 168.244463 104.929494) (xy 168.323815 105.026185) (xy 168.420506 105.105537) (xy 168.49 105.142683) (xy 168.490001 108.362668) + (xy 168.486324 108.4) (xy 168.490001 108.437333) (xy 168.500998 108.548986) (xy 168.50721 108.569463) (xy 168.544454 108.692246) + (xy 168.615026 108.824276) (xy 168.675829 108.898364) (xy 168.71 108.940001) (xy 168.738998 108.963799) (xy 169.117122 109.341923) + (xy 169.140001 109.397159) (xy 169.14 110.485673) (xy 169.136324 110.522996) (xy 169.14 110.560318) (xy 169.14 110.560328) + (xy 169.150997 110.671981) (xy 169.19119 110.804482) (xy 169.194454 110.815242) (xy 169.265026 110.947272) (xy 169.28823 110.975546) + (xy 169.359999 111.062997) (xy 169.389003 111.0868) (xy 170.648602 112.3464) (xy 168.483846 112.3464) (xy 168.543367 112.257321) + (xy 168.606311 112.10536) (xy 168.6384 111.94404) (xy 168.6384 111.77956) (xy 168.606311 111.61824) (xy 168.543367 111.466279) + (xy 168.451987 111.329519) (xy 168.335681 111.213213) (xy 168.198921 111.121833) (xy 168.04696 111.058889) (xy 167.88564 111.0268) + (xy 167.72116 111.0268) (xy 167.55984 111.058889) (xy 167.456243 111.1018) (xy 166.764397 111.1018) (xy 166.66855 111.062099) + (xy 166.50723 111.03001) (xy 166.34275 111.03001) (xy 166.18143 111.062099) (xy 166.029469 111.125043) (xy 165.892709 111.216423) + (xy 165.776403 111.332729) (xy 165.685023 111.469489) (xy 165.622079 111.62145) (xy 165.58999 111.78277) (xy 165.58999 111.94725) + (xy 165.622079 112.10857) (xy 165.685023 112.260531) (xy 165.742399 112.3464) (xy 163.836311 112.3464) (xy 163.798988 112.342724) + (xy 163.761666 112.3464) (xy 163.761655 112.3464) (xy 163.650002 112.357397) (xy 163.521391 112.39641) (xy 163.500209 112.39641) + (xy 163.371598 112.357397) (xy 163.259945 112.3464) (xy 163.259934 112.3464) (xy 163.222612 112.342724) (xy 163.18529 112.3464) + (xy 156.751823 112.3464) (xy 156.7145 112.342724) (xy 156.677177 112.3464) (xy 156.677168 112.3464) (xy 156.565515 112.357397) + (xy 156.422254 112.400854) (xy 156.290225 112.471426) (xy 156.1745 112.566399) (xy 156.150701 112.595398) (xy 155.688998 113.057102) + (xy 155.66 113.0809) (xy 155.636202 113.109898) (xy 155.636201 113.109899) (xy 155.565026 113.196625) (xy 155.494454 113.328655) + (xy 155.472514 113.400984) (xy 155.450998 113.471915) (xy 155.442078 113.562481) (xy 155.436324 113.620901) (xy 155.440001 113.658233) + (xy 155.440001 113.776928) (xy 155.4 113.776928) (xy 155.275518 113.789188) (xy 155.15582 113.825498) (xy 155.045506 113.884463) + (xy 154.948815 113.963815) (xy 154.869463 114.060506) (xy 154.810498 114.17082) (xy 154.777728 114.278848) (xy 154.775524 114.280026) + (xy 154.659799 114.374999) (xy 154.636 114.403998) (xy 154.287602 114.752397) (xy 154.258599 114.776199) (xy 154.217716 114.826016) + (xy 154.163626 114.891924) (xy 154.1298 114.955208) (xy 154.1298 114.83276) (xy 154.097711 114.67144) (xy 154.034767 114.519479) + (xy 153.943387 114.382719) (xy 153.827081 114.266413) (xy 153.690321 114.175033) (xy 153.53836 114.112089) (xy 153.37704 114.08) + (xy 153.21256 114.08) (xy 153.05124 114.112089) (xy 152.899279 114.175033) (xy 152.762519 114.266413) (xy 152.646213 114.382719) + (xy 152.554833 114.519479) (xy 152.491889 114.67144) (xy 152.4598 114.83276) (xy 152.4598 114.99724) (xy 152.491889 115.15856) + (xy 152.534801 115.262159) (xy 152.5348 116.30185) (xy 152.52778 116.298098) (xy 152.408082 116.261788) (xy 152.2836 116.249528) + (xy 150.2836 116.249528) (xy 150.159118 116.261788) (xy 150.03942 116.298098) (xy 149.929106 116.357063) (xy 149.832415 116.436415) + (xy 149.753063 116.533106) (xy 149.694098 116.64342) (xy 149.657788 116.763118) (xy 149.645528 116.8876) (xy 149.645528 117.8876) + (xy 149.657788 118.012082) (xy 149.694098 118.13178) (xy 149.753063 118.242094) (xy 149.769892 118.2626) (xy 149.753063 118.283106) + (xy 149.694098 118.39342) (xy 149.657788 118.513118) (xy 149.645528 118.6376) (xy 149.645528 118.789227) (xy 149.482903 118.626602) + (xy 149.459101 118.597599) (xy 149.343376 118.502626) (xy 149.211347 118.432054) (xy 149.068086 118.388597) (xy 148.956433 118.3776) + (xy 148.956422 118.3776) (xy 148.9191 118.373924) (xy 148.881778 118.3776) (xy 148.464646 118.3776) (xy 148.414137 118.283106) + (xy 148.397308 118.2626) (xy 148.414137 118.242094) (xy 148.473102 118.13178) (xy 148.509412 118.012082) (xy 148.521672 117.8876) + (xy 148.5186 117.67335) (xy 148.35985 117.5146) (xy 147.0106 117.5146) (xy 147.0106 117.5346) (xy 146.7566 117.5346) + (xy 146.7566 117.5146) (xy 146.7366 117.5146) (xy 146.7366 117.2606) (xy 146.7566 117.2606) (xy 146.7566 116.41135) + (xy 147.0106 116.41135) (xy 147.0106 117.2606) (xy 148.35985 117.2606) (xy 148.5186 117.10185) (xy 148.521672 116.8876) + (xy 148.509412 116.763118) (xy 148.473102 116.64342) (xy 148.414137 116.533106) (xy 148.334785 116.436415) (xy 148.238094 116.357063) + (xy 148.12778 116.298098) (xy 148.008082 116.261788) (xy 147.8836 116.249528) (xy 147.16935 116.2526) (xy 147.0106 116.41135) + (xy 146.7566 116.41135) (xy 146.59785 116.2526) (xy 145.8836 116.249528) (xy 145.759118 116.261788) (xy 145.63942 116.298098) + (xy 145.529106 116.357063) (xy 145.432415 116.436415) (xy 145.353063 116.533106) (xy 145.294098 116.64342) (xy 145.257788 116.763118) + (xy 145.245528 116.8876) (xy 145.2486 117.10185) (xy 145.407348 117.260598) (xy 145.2486 117.260598) (xy 145.2486 117.3768) + (xy 145.14056 117.3768) (xy 144.97924 117.408889) (xy 144.827279 117.471833) (xy 144.690519 117.563213) (xy 144.644333 117.609399) + (xy 144.592984 117.513334) (xy 144.581157 117.498923) (xy 144.498011 117.397609) (xy 144.469007 117.373806) (xy 144.253079 117.157878) + (xy 144.210167 117.054279) (xy 144.118787 116.917519) (xy 144.002481 116.801213) (xy 143.865721 116.709833) (xy 143.71376 116.646889) + (xy 143.55244 116.6148) (xy 143.38796 116.6148) (xy 143.304826 116.631337) (xy 143.289502 116.58082) (xy 143.230537 116.470506) + (xy 143.151185 116.373815) (xy 143.054494 116.294463) (xy 142.94418 116.235498) (xy 142.824482 116.199188) (xy 142.7 116.186928) + (xy 142.18575 116.19) (xy 142.027002 116.348748) (xy 142.027002 116.19) (xy 141.9604 116.19) (xy 141.9604 115.984077) + (xy 141.963835 115.9492) (xy 141.950127 115.810016) (xy 141.909528 115.67618) (xy 141.880882 115.622586) (xy 141.959787 115.543681) + (xy 142.051167 115.406921) (xy 142.114111 115.25496) (xy 142.1462 115.09364) (xy 142.1462 114.92916) (xy 142.114111 114.76784) + (xy 142.051167 114.615879) (xy 141.959787 114.479119) (xy 141.843481 114.362813) (xy 141.706721 114.271433) (xy 141.55476 114.208489) + (xy 141.39344 114.1764) (xy 141.22896 114.1764) (xy 141.06764 114.208489) (xy 140.964043 114.2514) (xy 138.224323 114.2514) + (xy 138.187 114.247724) (xy 138.149677 114.2514) (xy 138.149667 114.2514) (xy 138.038014 114.262397) (xy 137.910712 114.301013) + (xy 137.894753 114.305854) (xy 137.762723 114.376426) (xy 137.696956 114.4304) (xy 137.646999 114.471399) (xy 137.6232 114.500398) + (xy 137.26559 114.858009) (xy 137.160435 114.914216) (xy 137.04471 115.009189) (xy 137.020907 115.038193) (xy 136.588998 115.470102) + (xy 136.56 115.4939) (xy 136.536202 115.522898) (xy 136.536201 115.522899) (xy 136.465026 115.609625) (xy 136.394454 115.741655) + (xy 136.373569 115.810506) (xy 136.350998 115.884915) (xy 136.343445 115.961601) (xy 136.336324 116.033901) (xy 136.340001 116.071233) + (xy 136.340001 116.186928) (xy 136.3 116.186928) (xy 136.175518 116.199188) (xy 136.05582 116.235498) (xy 135.945506 116.294463) + (xy 135.848815 116.373815) (xy 135.769463 116.470506) (xy 135.710498 116.58082) (xy 135.674188 116.700518) (xy 135.661928 116.825) + (xy 135.661928 117.1228) (xy 135.53936 117.1228) (xy 135.37804 117.154889) (xy 135.226079 117.217833) (xy 135.089319 117.309213) + (xy 134.973013 117.425519) (xy 134.881633 117.562279) (xy 134.818689 117.71424) (xy 134.7866 117.87556) (xy 134.7866 118.04004) + (xy 134.818689 118.20136) (xy 134.881633 118.353321) (xy 134.911001 118.397274) (xy 134.866557 118.504572) (xy 134.834468 118.665892) + (xy 134.834468 118.830372) (xy 134.866557 118.991692) (xy 134.909469 119.095291) (xy 134.909468 120.203545) (xy 134.905792 120.240868) + (xy 134.909468 120.27819) (xy 134.909468 120.2782) (xy 134.920465 120.389853) (xy 134.955944 120.506814) (xy 134.963922 120.533114) + (xy 135.034494 120.665144) (xy 135.065331 120.702718) (xy 135.129467 120.780869) (xy 135.15847 120.804671) (xy 135.7688 121.415002) + (xy 135.792599 121.444001) (xy 135.908324 121.538974) (xy 136.040353 121.609546) (xy 136.183614 121.653003) (xy 136.295267 121.664) + (xy 136.295276 121.664) (xy 136.332599 121.667676) (xy 136.369922 121.664) (xy 137.738836 121.664) (xy 137.414424 121.988412) + (xy 137.120583 122.428175) (xy 136.918183 122.916814) (xy 136.815 123.435551) (xy 136.815 123.964449) (xy 136.918183 124.483186) + (xy 136.923749 124.496623) (xy 136.701302 124.347989) (xy 136.392012 124.219877) (xy 136.427932 124.133158) (xy 136.485 123.84626) + (xy 136.485 123.55374) (xy 136.427932 123.266842) (xy 136.31599 122.996589) (xy 136.153475 122.753368) (xy 135.946632 122.546525) + (xy 135.703411 122.38401) (xy 135.433158 122.272068) (xy 135.14626 122.215) (xy 134.976697 122.215) (xy 134.882327 122.175911) + (xy 134.576109 122.115) (xy 134.263891 122.115) (xy 133.957673 122.175911) (xy 133.669221 122.295391) (xy 133.409621 122.46885) + (xy 133.18885 122.689621) (xy 133.015391 122.949221) (xy 132.895911 123.237673) (xy 132.835 123.543891) (xy 132.835 123.856109) + (xy 132.895911 124.162327) (xy 133.015391 124.450779) (xy 133.18885 124.710379) (xy 133.409621 124.93115) (xy 133.669221 125.104609) + (xy 133.835016 125.173283) (xy 133.797988 125.228699) (xy 133.637047 125.617245) (xy 133.555 126.029722) (xy 133.555 126.45028) + (xy 133.637047 126.862757) (xy 133.769252 127.181928) (xy 132.65 127.181928) (xy 132.525518 127.194188) (xy 132.40582 127.230498) + (xy 132.295506 127.289463) (xy 132.198815 127.368815) (xy 132.119463 127.465506) (xy 132.060498 127.57582) (xy 132.024188 127.695518) + (xy 132.011928 127.82) (xy 132.011928 128.640326) (xy 130.5396 127.167999) (xy 130.5396 122.445157) (xy 130.582511 122.34156) + (xy 130.6146 122.18024) (xy 130.6146 122.01576) (xy 130.582511 121.85444) (xy 130.519567 121.702479) (xy 130.428187 121.565719) + (xy 130.311881 121.449413) (xy 130.175121 121.358033) (xy 130.071522 121.315121) (xy 129.845404 121.089003) (xy 129.821601 121.059999) + (xy 129.705876 120.965026) (xy 129.573847 120.894454) (xy 129.430586 120.850997) (xy 129.318933 120.84) (xy 129.318922 120.84) + (xy 129.2816 120.836324) (xy 129.244278 120.84) (xy 128.767683 120.84) (xy 128.730537 120.770506) (xy 128.651185 120.673815) + (xy 128.554494 120.594463) (xy 128.44418 120.535498) (xy 128.324482 120.499188) (xy 128.2 120.486928) (xy 126.9 120.486928) + (xy 126.775518 120.499188) (xy 126.65582 120.535498) (xy 126.545506 120.594463) (xy 126.448815 120.673815) (xy 126.369463 120.770506) + (xy 126.310498 120.88082) (xy 126.274188 121.000518) (xy 126.261928 121.125) (xy 126.261928 122.075) (xy 126.274188 122.199482) + (xy 126.310498 122.31918) (xy 126.369463 122.429494) (xy 126.448815 122.526185) (xy 126.545506 122.605537) (xy 126.65582 122.664502) + (xy 126.775518 122.700812) (xy 126.9 122.713072) (xy 128.2 122.713072) (xy 128.324482 122.700812) (xy 128.44418 122.664502) + (xy 128.554494 122.605537) (xy 128.651185 122.526185) (xy 128.730537 122.429494) (xy 128.767683 122.36) (xy 128.966799 122.36) + (xy 128.996721 122.389922) (xy 129.0196 122.445157) (xy 129.0196 123.365) (xy 128.91776 123.365) (xy 128.75644 123.397089) + (xy 128.746866 123.401055) (xy 128.730537 123.370506) (xy 128.651185 123.273815) (xy 128.554494 123.194463) (xy 128.44418 123.135498) + (xy 128.324482 123.099188) (xy 128.2 123.086928) (xy 126.9 123.086928) (xy 126.775518 123.099188) (xy 126.65582 123.135498) + (xy 126.545506 123.194463) (xy 126.448815 123.273815) (xy 126.369463 123.370506) (xy 126.310498 123.48082) (xy 126.274188 123.600518) + (xy 126.261928 123.725) (xy 126.261928 124.675) (xy 126.274188 124.799482) (xy 126.310498 124.91918) (xy 126.369463 125.029494) + (xy 126.448815 125.126185) (xy 126.545506 125.205537) (xy 126.65582 125.264502) (xy 126.775518 125.300812) (xy 126.9 125.313072) + (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) (xy 128.554494 125.205537) (xy 128.651185 125.126185) + (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) (xy 128.91776 125.035) (xy 129.019601 125.035) + (xy 129.019601 127.445468) (xy 129.015924 127.4828) (xy 129.019601 127.520133) (xy 129.030598 127.631786) (xy 129.036621 127.651642) + (xy 129.074054 127.775046) (xy 129.144626 127.907076) (xy 129.204773 127.980364) (xy 129.2396 128.022801) (xy 129.268598 128.046599) + (xy 131.841522 130.619524) (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) (xy 132.228879 131.067567) + (xy 132.38084 131.130511) (xy 132.54216 131.1626) (xy 132.70664 131.1626) (xy 132.86796 131.130511) (xy 133.019921 131.067567) + (xy 133.156681 130.976187) (xy 133.272987 130.859881) (xy 133.364367 130.723121) (xy 133.368454 130.713255) (xy 134.1002 131.445002) + (xy 134.123998 131.474) (xy 134.152996 131.497798) (xy 134.239722 131.568973) (xy 134.366218 131.636587) (xy 134.371752 131.639545) + (xy 134.515013 131.683002) (xy 134.626666 131.693999) (xy 134.626675 131.693999) (xy 134.663998 131.697675) (xy 134.701321 131.693999) + (xy 137.473 131.693999) (xy 137.426999 131.74) (xy 126.937322 131.74) (xy 126.899999 131.736324) (xy 126.862676 131.74) + (xy 126.862667 131.74) (xy 126.751014 131.750997) (xy 126.631235 131.787331) (xy 126.607753 131.794454) (xy 126.475723 131.865026) + (xy 126.394815 131.931426) (xy 126.359999 131.959999) (xy 126.336201 131.988997) (xy 125.789234 132.535964) (xy 125.789234 130.57257) + (xy 126.564013 130.364969) (xy 126.68108 130.320908) (xy 126.787302 130.254856) (xy 126.878596 130.169349) (xy 126.951455 130.067675) + (xy 127.003078 129.953741) (xy 127.031481 129.831924) (xy 127.035574 129.706907) (xy 127.015198 129.583494) (xy 126.49756 127.651642) + (xy 126.453499 127.534575) (xy 126.387447 127.428353) (xy 126.30194 127.337059) (xy 126.200266 127.2642) (xy 126.086332 127.212577) + (xy 125.964515 127.184174) (xy 125.839498 127.180081) (xy 125.716085 127.200457) (xy 123.982326 127.665016) (xy 124.030992 127.547526) + (xy 124.091903 127.241308) (xy 124.091903 126.92909) (xy 124.030992 126.622872) (xy 123.911512 126.33442) (xy 123.738053 126.07482) + (xy 123.517282 125.854049) (xy 123.257682 125.68059) (xy 122.96923 125.56111) (xy 122.663012 125.500199) (xy 122.350794 125.500199) + (xy 122.044576 125.56111) (xy 121.756124 125.68059) (xy 121.588772 125.792411) (xy 121.513508 125.807382) (xy 121.243255 125.919324) + (xy 121.000034 126.081839) (xy 120.793191 126.288682) (xy 120.630676 126.531903) (xy 120.518734 126.802156) (xy 120.461666 127.089054) + (xy 120.461666 127.381574) (xy 120.518734 127.668472) (xy 120.630676 127.938725) (xy 120.738829 128.100587) (xy 120.576595 128.208988) + (xy 120.285 128.500583) (xy 120.285 128.135551) (xy 120.181817 127.616814) (xy 119.979417 127.128175) (xy 119.685576 126.688412) + (xy 119.660219 126.663055) (xy 119.75644 126.702911) (xy 119.91776 126.735) (xy 120.08224 126.735) (xy 120.24356 126.702911) + (xy 120.395521 126.639967) (xy 120.532281 126.548587) (xy 120.648587 126.432281) (xy 120.739967 126.295521) (xy 120.802911 126.14356) + (xy 120.835 125.98224) (xy 120.835 125.81776) (xy 120.802911 125.65644) (xy 120.739967 125.504479) (xy 120.648587 125.367719) + (xy 120.532281 125.251413) (xy 120.511776 125.237712) (xy 120.539967 125.195521) (xy 120.602911 125.04356) (xy 120.635 124.88224) + (xy 120.635 124.71776) (xy 120.602911 124.55644) (xy 120.56 124.452843) (xy 120.56 124.427565) (xy 120.563676 124.390242) + (xy 120.56 124.352919) (xy 120.56 124.352911) (xy 120.549003 124.241257) (xy 120.505546 124.097996) (xy 120.434974 123.965967) + (xy 120.340001 123.850242) (xy 120.311003 123.826444) (xy 120.236894 123.752335) (xy 120.255947 123.67062) (xy 120.26004 123.545603) + (xy 120.239664 123.42219) (xy 120.15787 123.116931) (xy 120.291923 122.982878) (xy 120.395521 122.939967) (xy 120.532281 122.848587) + (xy 120.648587 122.732281) (xy 120.739967 122.595521) (xy 120.802911 122.44356) (xy 120.835 122.28224) (xy 120.835 122.11776) + (xy 120.802911 121.95644) (xy 120.739967 121.804479) (xy 120.648587 121.667719) (xy 120.631228 121.65036) (xy 121.8976 121.65036) + (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.992633 122.128121) (xy 122.084013 122.264881) (xy 122.200319 122.381187) + (xy 122.337079 122.472567) (xy 122.482012 122.5326) (xy 122.337079 122.592633) (xy 122.200319 122.684013) (xy 122.084013 122.800319) + (xy 121.992633 122.937079) (xy 121.929689 123.08904) (xy 121.8976 123.25036) (xy 121.8976 123.41484) (xy 121.929689 123.57616) + (xy 121.9726 123.679757) (xy 121.9726 123.895278) (xy 121.968924 123.9326) (xy 121.9726 123.969922) (xy 121.9726 123.969932) + (xy 121.983597 124.081585) (xy 122.021393 124.206185) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.135817 124.403411) + (xy 122.192599 124.472601) (xy 122.221603 124.496404) (xy 122.436196 124.710997) (xy 122.459999 124.740001) (xy 122.575724 124.834974) + (xy 122.707753 124.905546) (xy 122.762007 124.922004) (xy 122.819463 125.029494) (xy 122.898815 125.126185) (xy 122.995506 125.205537) + (xy 123.10582 125.264502) (xy 123.225518 125.300812) (xy 123.35 125.313072) (xy 124.65 125.313072) (xy 124.774482 125.300812) + (xy 124.89418 125.264502) (xy 125.004494 125.205537) (xy 125.101185 125.126185) (xy 125.180537 125.029494) (xy 125.239502 124.91918) + (xy 125.275812 124.799482) (xy 125.288072 124.675) (xy 125.288072 123.725) (xy 125.275812 123.600518) (xy 125.239502 123.48082) + (xy 125.180537 123.370506) (xy 125.101185 123.273815) (xy 125.004494 123.194463) (xy 124.89418 123.135498) (xy 124.774482 123.099188) + (xy 124.65 123.086928) (xy 123.534636 123.086928) (xy 123.472567 122.937079) (xy 123.381187 122.800319) (xy 123.287816 122.706948) + (xy 123.35 122.713072) (xy 124.65 122.713072) (xy 124.774482 122.700812) (xy 124.89418 122.664502) (xy 125.004494 122.605537) + (xy 125.101185 122.526185) (xy 125.180537 122.429494) (xy 125.239502 122.31918) (xy 125.275812 122.199482) (xy 125.288072 122.075) + (xy 125.288072 121.125) (xy 125.275812 121.000518) (xy 125.239502 120.88082) (xy 125.180537 120.770506) (xy 125.101185 120.673815) + (xy 125.004494 120.594463) (xy 124.89418 120.535498) (xy 124.774482 120.499188) (xy 124.65 120.486928) (xy 123.35 120.486928) + (xy 123.225518 120.499188) (xy 123.10582 120.535498) (xy 122.995506 120.594463) (xy 122.898815 120.673815) (xy 122.819463 120.770506) + (xy 122.779786 120.844736) (xy 122.716214 120.850997) (xy 122.572953 120.894454) (xy 122.517699 120.923988) (xy 122.48904 120.929689) + (xy 122.337079 120.992633) (xy 122.200319 121.084013) (xy 122.084013 121.200319) (xy 121.992633 121.337079) (xy 121.929689 121.48904) + (xy 121.8976 121.65036) (xy 120.631228 121.65036) (xy 120.532281 121.551413) (xy 120.395521 121.460033) (xy 120.24356 121.397089) + (xy 120.08224 121.365) (xy 119.91776 121.365) (xy 119.75644 121.397089) (xy 119.610392 121.457584) (xy 119.533884 121.413412) + (xy 118.423794 121.71086) (xy 118.42897 121.730178) (xy 118.41826 121.733048) (xy 118.342167 121.449065) (xy 118.352878 121.446195) + (xy 118.358054 121.465514) (xy 119.468144 121.168067) (xy 119.580397 120.973638) (xy 119.527912 120.765894) (xy 119.483852 120.648826) + (xy 119.417799 120.542605) (xy 119.332292 120.451311) (xy 119.230618 120.378452) (xy 119.116684 120.32683) (xy 118.994868 120.298425) + (xy 118.86985 120.294333) (xy 118.746437 120.314709) (xy 118.250505 120.450774) (xy 118.138253 120.645199) (xy 118.097166 120.491861) + (xy 118.086453 120.494731) (xy 118.027859 120.276054) (xy 118.022151 120.241484) (xy 118.009809 120.208692) (xy 118.009807 120.208684) + (xy 117.972887 120.11059) (xy 117.899032 119.991823) (xy 117.803427 119.889746) (xy 117.689744 119.808281) (xy 117.562352 119.750561) + (xy 117.426149 119.718803) (xy 117.286366 119.714227) (xy 117.286365 119.714227) (xy 117.182953 119.7313) (xy 117.182948 119.731301) + (xy 117.148377 119.737009) (xy 117.115583 119.749352) (xy 116.935 119.797739) (xy 116.935 119.71776) (xy 116.902911 119.55644) + (xy 116.839967 119.404479) (xy 116.748587 119.267719) (xy 116.632281 119.151413) (xy 116.495521 119.060033) (xy 116.34356 118.997089) + (xy 116.18224 118.965) (xy 116.01776 118.965) (xy 115.85644 118.997089) (xy 115.752843 119.04) (xy 114.91455 119.04) + (xy 114.877217 119.036323) (xy 114.839884 119.04) (xy 114.728231 119.050997) (xy 114.58497 119.094454) (xy 114.452941 119.165026) + (xy 114.337216 119.259999) (xy 114.313418 119.288997) (xy 113.555582 120.046834) (xy 113.639967 119.920542) (xy 113.702911 119.768581) + (xy 113.735 119.607261) (xy 113.735 119.442781) (xy 113.702911 119.281461) (xy 113.639967 119.1295) (xy 113.548587 118.99274) + (xy 113.515847 118.96) (xy 121.638999 118.96) (xy 121.990922 119.311923) (xy 122.033833 119.415521) (xy 122.125213 119.552281) + (xy 122.241519 119.668587) (xy 122.378279 119.759967) (xy 122.53024 119.822911) (xy 122.69156 119.855) (xy 122.853982 119.855) + (xy 122.928815 119.946185) (xy 123.025506 120.025537) (xy 123.13582 120.084502) (xy 123.255518 120.120812) (xy 123.38 120.133072) + (xy 124.68 120.133072) (xy 124.804482 120.120812) (xy 124.92418 120.084502) (xy 125.034494 120.025537) (xy 125.131185 119.946185) + (xy 125.210537 119.849494) (xy 125.269502 119.73918) (xy 125.305812 119.619482) (xy 125.318072 119.495) (xy 125.318072 119.25) + (xy 125.34064 119.25) (xy 125.50196 119.217911) (xy 125.653921 119.154967) (xy 125.790681 119.063587) (xy 125.906987 118.947281) + (xy 125.998367 118.810521) (xy 126.061311 118.65856) (xy 126.083899 118.545) (xy 126.291928 118.545) (xy 126.291928 119.495) + (xy 126.304188 119.619482) (xy 126.340498 119.73918) (xy 126.399463 119.849494) (xy 126.478815 119.946185) (xy 126.575506 120.025537) + (xy 126.68582 120.084502) (xy 126.805518 120.120812) (xy 126.93 120.133072) (xy 128.23 120.133072) (xy 128.354482 120.120812) + (xy 128.47418 120.084502) (xy 128.584494 120.025537) (xy 128.681185 119.946185) (xy 128.756018 119.855) (xy 128.76504 119.855) + (xy 128.92636 119.822911) (xy 129.078321 119.759967) (xy 129.215081 119.668587) (xy 129.331387 119.552281) (xy 129.422767 119.415521) + (xy 129.485711 119.26356) (xy 129.5178 119.10224) (xy 129.5178 118.93776) (xy 129.485711 118.77644) (xy 129.422767 118.624479) + (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) (xy 128.92636 118.217089) (xy 128.76504 118.185) + (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) (xy 128.47418 117.955498) (xy 128.354482 117.919188) + (xy 128.23 117.906928) (xy 126.93 117.906928) (xy 126.805518 117.919188) (xy 126.68582 117.955498) (xy 126.575506 118.014463) + (xy 126.478815 118.093815) (xy 126.399463 118.190506) (xy 126.340498 118.30082) (xy 126.304188 118.420518) (xy 126.291928 118.545) + (xy 126.083899 118.545) (xy 126.0934 118.49724) (xy 126.0934 118.33276) (xy 126.061311 118.17144) (xy 125.998367 118.019479) + (xy 125.9676 117.973433) (xy 125.9676 117.475157) (xy 126.010511 117.37156) (xy 126.032383 117.261602) (xy 129.99428 117.261602) + (xy 130.031602 117.265278) (xy 130.068924 117.261602) (xy 130.068935 117.261602) (xy 130.180588 117.250605) (xy 130.323849 117.207148) + (xy 130.455878 117.136576) (xy 130.571603 117.041603) (xy 130.595405 117.0126) (xy 131.284549 116.323456) (xy 131.313548 116.299658) + (xy 131.408521 116.183933) (xy 131.479093 116.051904) (xy 131.52255 115.908643) (xy 131.533547 115.79699) (xy 131.533547 115.796982) + (xy 131.537223 115.759657) (xy 131.533547 115.722332) (xy 131.533547 113.975704) (xy 131.576458 113.872107) (xy 131.608547 113.710787) + (xy 131.608547 113.546307) (xy 131.576458 113.384987) (xy 131.513514 113.233026) (xy 131.422134 113.096266) (xy 131.305828 112.97996) + (xy 131.169068 112.88858) (xy 131.017107 112.825636) (xy 130.855787 112.793547) (xy 130.691307 112.793547) (xy 130.529987 112.825636) + (xy 130.378026 112.88858) (xy 130.241266 112.97996) (xy 130.12496 113.096266) (xy 130.03358 113.233026) (xy 129.970636 113.384987) + (xy 129.938547 113.546307) (xy 129.938547 113.710787) (xy 129.970636 113.872107) (xy 130.013547 113.975704) (xy 130.013547 114.163745) + (xy 128.807879 112.958077) (xy 128.764967 112.854479) (xy 128.673587 112.717719) (xy 128.557281 112.601413) (xy 128.420521 112.510033) + (xy 128.26856 112.447089) (xy 128.26 112.445386) (xy 128.26 111.318072) (xy 128.65 111.318072) (xy 128.774482 111.305812) + (xy 128.89418 111.269502) (xy 129.004494 111.210537) (xy 129.101185 111.131185) (xy 129.180537 111.034494) (xy 129.239502 110.92418) + (xy 129.275812 110.804482) (xy 129.288072 110.68) (xy 129.288072 108.68) (xy 129.275812 108.555518) (xy 129.239502 108.43582) + (xy 129.180537 108.325506) (xy 129.101185 108.228815) (xy 129.004494 108.149463) (xy 128.89418 108.090498) (xy 128.774482 108.054188) + (xy 128.65 108.041928) (xy 126.856887 108.041928) (xy 126.984609 107.850779) (xy 127.104089 107.562327) (xy 127.165 107.256109) + (xy 127.165 106.943891) (xy 127.104089 106.637673) (xy 126.984609 106.349221) (xy 126.81115 106.089621) (xy 126.590379 105.86885) + (xy 126.330779 105.695391) (xy 126.042327 105.575911) (xy 125.736109 105.515) (xy 125.423891 105.515) (xy 125.117673 105.575911) + (xy 125.023303 105.615) (xy 124.85374 105.615) (xy 124.566842 105.672068) (xy 124.296589 105.78401) (xy 124.053368 105.946525) + (xy 123.846525 106.153368) (xy 123.68401 106.396589) (xy 123.572068 106.666842) (xy 123.515 106.95374) (xy 123.515 107.24626) + (xy 123.572068 107.533158) (xy 123.607988 107.619876) (xy 123.298698 107.747988) (xy 123.076252 107.896622) (xy 123.081817 107.883186) + (xy 123.185 107.364449) (xy 123.185 106.835551) (xy 123.081817 106.316814) (xy 122.879417 105.828175) (xy 122.585576 105.388412) + (xy 122.211588 105.014424) (xy 121.771825 104.720583) (xy 121.384142 104.56) (xy 122.215123 104.56) (xy 122.25 104.563435) + (xy 122.284877 104.56) (xy 122.389184 104.549727) (xy 122.52302 104.509128) (xy 122.646363 104.4432) (xy 122.754475 104.354475) + (xy 122.8432 104.246363) (xy 122.909128 104.12302) (xy 122.949727 103.989184) (xy 122.963435 103.85) (xy 122.96 103.815123) + (xy 122.96 103.613072) (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) + (xy 124.151185 103.426185) (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) + (xy 124.338072 102.686729) (xy 124.741923 102.282878) (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) + (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) + (xy 125.189967 101.104479) (xy 125.098587 100.967719) (xy 124.982281 100.851413) (xy 124.845521 100.760033) (xy 124.69356 100.697089) + (xy 124.53224 100.665) (xy 124.36776 100.665) (xy 124.335 100.671516) (xy 124.335 100.597998) (xy 124.176252 100.597998) + (xy 124.335 100.43925) (xy 124.338072 100.225) (xy 124.325812 100.100518) (xy 124.289502 99.98082) (xy 124.230537 99.870506) + (xy 124.151185 99.773815) (xy 124.054494 99.694463) (xy 123.94418 99.635498) (xy 123.824482 99.599188) (xy 123.7 99.586928) + (xy 123.18575 99.59) (xy 123.027002 99.748748) (xy 123.027002 99.59) (xy 122.96 99.59) (xy 122.96 99.439) + (xy 126.257197 99.439) (xy 128.726203 101.908008) (xy 128.749997 101.937001) (xy 128.77899 101.960795) (xy 128.778994 101.960799) + (xy 128.831241 102.003676) (xy 128.865722 102.031974) (xy 128.997751 102.102546) (xy 129.141012 102.146003) (xy 129.252665 102.157) + (xy 129.252674 102.157) (xy 129.289997 102.160676) (xy 129.326263 102.157104) (xy 129.355665 102.16) (xy 129.402843 102.16) + (xy 129.50644 102.202911) (xy 129.66776 102.235) (xy 129.83224 102.235) (xy 129.912691 102.218997) (xy 129.935498 102.29418) + (xy 129.994463 102.404494) (xy 130.073815 102.501185) (xy 130.170506 102.580537) (xy 130.28082 102.639502) (xy 130.400518 102.675812) + (xy 130.525 102.688072) (xy 131.475 102.688072) (xy 131.599482 102.675812) (xy 131.71918 102.639502) (xy 131.829494 102.580537) + (xy 131.926185 102.501185) (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) + (xy 132.113072 101.982618) (xy 132.165001 101.940001) (xy 132.188803 101.910998) (xy 134.011009 100.088794) (xy 134.040001 100.065001) + (xy 134.063795 100.036008) (xy 134.063799 100.036004) (xy 134.134973 99.949277) (xy 134.134974 99.949276) (xy 134.205546 99.817247) + (xy 134.249003 99.673986) (xy 134.249136 99.672634) (xy 134.26059 99.694063) (xy 134.343468 99.79505) (xy 135.118466 100.570049) + (xy 135.146179 100.603817) (xy 135.179947 100.63153) (xy 135.179949 100.631532) (xy 135.25983 100.697089) (xy 135.280937 100.714411) + (xy 135.434683 100.796589) (xy 135.601506 100.847195) (xy 135.731519 100.86) (xy 135.731527 100.86) (xy 135.732361 100.860082) + (xy 135.769463 100.929494) (xy 135.848815 101.026185) (xy 135.945506 101.105537) (xy 136.05582 101.164502) (xy 136.175518 101.200812) + (xy 136.3 101.213072) (xy 137.04 101.213072) (xy 137.04 101.515123) (xy 137.036565 101.55) (xy 137.050273 101.689184) + (xy 137.090872 101.82302) (xy 137.1568 101.946363) (xy 137.245525 102.054475) (xy 137.330471 102.124188) (xy 137.353637 102.1432) + (xy 137.47698 102.209128) (xy 137.610816 102.249727) (xy 137.75 102.263435) (xy 137.784877 102.26) (xy 138.374436 102.26) + (xy 138.228175 102.320583) (xy 137.788412 102.614424) (xy 137.414424 102.988412) (xy 137.120583 103.428175) (xy 136.918183 103.916814) + (xy 136.815 104.435551) (xy 136.815 104.964449) (xy 136.918183 105.483186) (xy 136.923749 105.496623) (xy 136.701302 105.347989) + (xy 136.392012 105.219877) (xy 136.427932 105.133158) (xy 136.485 104.84626) (xy 136.485 104.55374) (xy 136.427932 104.266842) + (xy 136.31599 103.996589) (xy 136.153475 103.753368) (xy 135.946632 103.546525) (xy 135.703411 103.38401) (xy 135.433158 103.272068) + (xy 135.14626 103.215) (xy 134.976697 103.215) (xy 134.882327 103.175911) (xy 134.576109 103.115) (xy 134.263891 103.115) + (xy 133.957673 103.175911) (xy 133.669221 103.295391) (xy 133.409621 103.46885) (xy 133.18885 103.689621) (xy 133.015391 103.949221) + (xy 132.895911 104.237673) (xy 132.835 104.543891) (xy 132.835 104.856109) (xy 132.895911 105.162327) (xy 133.015391 105.450779) + (xy 133.18885 105.710379) (xy 133.409621 105.93115) (xy 133.669221 106.104609) (xy 133.835016 106.173283) (xy 133.797988 106.228699) + (xy 133.637047 106.617245) (xy 133.555 107.029722) (xy 133.555 107.45028) (xy 133.637047 107.862757) (xy 133.769252 108.181928) + (xy 132.65 108.181928) (xy 132.56 108.190792) (xy 132.56 105.787323) (xy 132.563676 105.75) (xy 132.56 105.712677) + (xy 132.56 105.612667) (xy 132.549003 105.501014) (xy 132.505546 105.357753) (xy 132.434974 105.225724) (xy 132.340001 105.109999) + (xy 132.224276 105.015026) (xy 132.113072 104.955585) (xy 132.113072 104.3) (xy 132.100812 104.175518) (xy 132.064502 104.05582) + (xy 132.005537 103.945506) (xy 131.926185 103.848815) (xy 131.829494 103.769463) (xy 131.71918 103.710498) (xy 131.599482 103.674188) + (xy 131.475 103.661928) (xy 130.525 103.661928) (xy 130.400518 103.674188) (xy 130.28082 103.710498) (xy 130.170506 103.769463) + (xy 130.073815 103.848815) (xy 129.994463 103.945506) (xy 129.935498 104.05582) (xy 129.899188 104.175518) (xy 129.886928 104.3) + (xy 129.886928 105.6) (xy 129.899188 105.724482) (xy 129.935498 105.84418) (xy 129.994463 105.954494) (xy 130.073815 106.051185) + (xy 130.170506 106.130537) (xy 130.28082 106.189502) (xy 130.400518 106.225812) (xy 130.525 106.238072) (xy 131.040001 106.238072) + (xy 131.04 108.602843) (xy 130.997089 108.70644) (xy 130.965 108.86776) (xy 130.965 109.03224) (xy 130.997089 109.19356) + (xy 131.040001 109.297159) (xy 131.04 111.712679) (xy 131.036324 111.750002) (xy 131.04 111.787324) (xy 131.04 111.787334) + (xy 131.050997 111.898987) (xy 131.083592 112.00644) (xy 131.094454 112.042248) (xy 131.165026 112.174278) (xy 131.19736 112.213677) + (xy 131.259999 112.290003) (xy 131.289002 112.313805) (xy 131.961204 112.986009) (xy 131.984998 113.015002) (xy 132.013991 113.038796) + (xy 132.013995 113.0388) (xy 132.064198 113.08) (xy 132.100723 113.109975) (xy 132.232752 113.180547) (xy 132.376013 113.224004) + (xy 132.487666 113.235001) (xy 132.487675 113.235001) (xy 132.524998 113.238677) (xy 132.562321 113.235001) (xy 145.487677 113.235001) + (xy 145.524999 113.238677) (xy 145.562321 113.235001) (xy 145.562332 113.235001) (xy 145.673985 113.224004) (xy 145.817246 113.180547) + (xy 145.949275 113.109975) (xy 146.065 113.015002) (xy 146.068071 113.01126) (xy 151.565 113.01126) (xy 151.565 113.17574) + (xy 151.597089 113.33706) (xy 151.660033 113.489021) (xy 151.751413 113.625781) (xy 151.867719 113.742087) (xy 152.004479 113.833467) + (xy 152.15644 113.896411) (xy 152.31776 113.9285) (xy 152.48224 113.9285) (xy 152.64356 113.896411) (xy 152.795521 113.833467) + (xy 152.860275 113.7902) (xy 154.339043 113.7902) (xy 154.44264 113.833111) (xy 154.60396 113.8652) (xy 154.76844 113.8652) + (xy 154.92976 113.833111) (xy 155.081721 113.770167) (xy 155.218481 113.678787) (xy 155.334787 113.562481) (xy 155.426167 113.425721) + (xy 155.489111 113.27376) (xy 155.5212 113.11244) (xy 155.5212 112.94796) (xy 155.489111 112.78664) (xy 155.426167 112.634679) + (xy 155.334787 112.497919) (xy 155.218481 112.381613) (xy 155.081721 112.290233) (xy 154.92976 112.227289) (xy 154.76844 112.1952) + (xy 154.60396 112.1952) (xy 154.44264 112.227289) (xy 154.339043 112.2702) (xy 152.541059 112.2702) (xy 152.48224 112.2585) + (xy 152.31776 112.2585) (xy 152.15644 112.290589) (xy 152.004479 112.353533) (xy 151.867719 112.444913) (xy 151.751413 112.561219) + (xy 151.660033 112.697979) (xy 151.597089 112.84994) (xy 151.565 113.01126) (xy 146.068071 113.01126) (xy 146.088803 112.985999) + (xy 147.011003 112.063799) (xy 147.040001 112.040001) (xy 147.134974 111.924276) (xy 147.205546 111.792247) (xy 147.249003 111.648986) + (xy 147.26 111.537333) (xy 147.26 111.537325) (xy 147.263676 111.5) (xy 147.26 111.462675) (xy 147.26 108.918072) + (xy 147.65 108.918072) (xy 147.774482 108.905812) (xy 147.89418 108.869502) (xy 148.004494 108.810537) (xy 148.101185 108.731185) + (xy 148.180537 108.634494) (xy 148.239502 108.52418) (xy 148.275812 108.404482) (xy 148.288072 108.28) (xy 148.288072 106.28) + (xy 148.275812 106.155518) (xy 148.239502 106.03582) (xy 148.180537 105.925506) (xy 148.101185 105.828815) (xy 148.004494 105.749463) + (xy 147.89418 105.690498) (xy 147.774482 105.654188) (xy 147.65 105.641928) (xy 145.856887 105.641928) (xy 145.984609 105.450779) + (xy 146.104089 105.162327) (xy 146.165 104.856109) (xy 146.165 104.543891) (xy 146.104089 104.237673) (xy 145.984609 103.949221) + (xy 145.81115 103.689621) (xy 145.590379 103.46885) (xy 145.330779 103.295391) (xy 145.042327 103.175911) (xy 144.736109 103.115) + (xy 144.423891 103.115) (xy 144.117673 103.175911) (xy 144.023303 103.215) (xy 143.85374 103.215) (xy 143.566842 103.272068) + (xy 143.296589 103.38401) (xy 143.053368 103.546525) (xy 142.846525 103.753368) (xy 142.68401 103.996589) (xy 142.572068 104.266842) + (xy 142.515 104.55374) (xy 142.515 104.84626) (xy 142.572068 105.133158) (xy 142.607988 105.219876) (xy 142.298698 105.347988) + (xy 142.076252 105.496622) (xy 142.081817 105.483186) (xy 142.185 104.964449) (xy 142.185 104.435551) (xy 142.081817 103.916814) + (xy 141.879417 103.428175) (xy 141.585576 102.988412) (xy 141.211588 102.614424) (xy 140.771825 102.320583) (xy 140.625564 102.26) + (xy 141.215123 102.26) (xy 141.25 102.263435) (xy 141.284877 102.26) (xy 141.389184 102.249727) (xy 141.52302 102.209128) + (xy 141.646363 102.1432) (xy 141.754475 102.054475) (xy 141.8432 101.946363) (xy 141.909128 101.82302) (xy 141.949727 101.689184) + (xy 141.963435 101.55) (xy 141.96 101.515123) (xy 141.96 101.213072) (xy 142.7 101.213072) (xy 142.824482 101.200812) + (xy 142.94418 101.164502) (xy 143.054494 101.105537) (xy 143.151185 101.026185) (xy 143.230537 100.929494) (xy 143.289502 100.81918) + (xy 143.325812 100.699482) (xy 143.330979 100.647014) (xy 143.400276 100.609974) (xy 143.516001 100.515001) (xy 143.539803 100.485998) + (xy 144.111004 99.914798) (xy 144.140001 99.891001) (xy 144.234974 99.775276) (xy 144.305546 99.643247) (xy 144.349003 99.499986) + (xy 144.35886 99.39991) (xy 144.402911 99.29356) (xy 144.435 99.13224) (xy 144.435 98.96776) (xy 144.402911 98.80644) + (xy 144.339967 98.654479) (xy 144.248587 98.517719) (xy 144.132281 98.401413) (xy 143.995521 98.310033) (xy 143.84356 98.247089) + (xy 143.68224 98.215) (xy 143.51776 98.215) (xy 143.35644 98.247089) (xy 143.335 98.25597) (xy 143.335 98.197998) + (xy 143.176252 98.197998) (xy 143.335 98.03925) (xy 143.338072 97.825) (xy 143.325812 97.700518) (xy 143.289502 97.58082) + (xy 143.230537 97.470506) (xy 143.151185 97.373815) (xy 143.054494 97.294463) (xy 142.94418 97.235498) (xy 142.824482 97.199188) + (xy 142.7 97.186928) (xy 142.18575 97.19) (xy 142.027002 97.348748) (xy 142.027002 97.19) (xy 141.96 97.19) + (xy 141.96 97.084877) (xy 141.963435 97.05) (xy 141.949727 96.910816) (xy 141.909128 96.77698) (xy 141.8432 96.653637) + (xy 141.754475 96.545525) (xy 141.646363 96.4568) (xy 141.52302 96.390872) (xy 141.389184 96.350273) (xy 141.284877 96.34) + (xy 141.25 96.336565) (xy 141.215123 96.34) (xy 137.784877 96.34) (xy 137.75 96.336565) (xy 137.715123 96.34) + (xy 137.610816 96.350273) (xy 137.47698 96.390872) (xy 137.353637 96.4568) (xy 137.245525 96.545525) (xy 137.1568 96.653637) + (xy 137.090872 96.77698) (xy 137.050273 96.910816) (xy 137.036565 97.05) (xy 137.040001 97.084887) (xy 137.040001 97.186928) + (xy 136.3 97.186928) (xy 136.175518 97.199188) (xy 136.05582 97.235498) (xy 135.945506 97.294463) (xy 135.848815 97.373815) + (xy 135.769463 97.470506) (xy 135.757338 97.493189) (xy 135.670753 97.519454) (xy 135.538724 97.590026) (xy 135.422999 97.684999) + (xy 135.399196 97.714003) (xy 135.189013 97.924186) (xy 135.160009 97.947989) (xy 135.112781 98.005537) (xy 135.065036 98.063714) + (xy 135.001431 98.182709) (xy 134.994464 98.195744) (xy 134.958342 98.314826) (xy 134.82651 98.327809) (xy 134.659687 98.378416) + (xy 134.505941 98.460594) (xy 134.371183 98.571187) (xy 134.26059 98.705945) (xy 134.26 98.707049) (xy 134.26 96.614801) + (xy 135.859999 95.014804) (xy 135.860008 95.014793) (xy 135.964801 94.91) (xy 149.240001 94.91) (xy 149.240001 95.572317) + (xy 149.170506 95.609463) (xy 149.073815 95.688815) (xy 148.994463 95.785506) (xy 148.935498 95.89582) (xy 148.899188 96.015518) + (xy 148.886928 96.14) (xy 148.886928 97.44) (xy 148.899188 97.564482) (xy 148.935498 97.68418) (xy 148.994463 97.794494) + (xy 149.073815 97.891185) (xy 149.165 97.966018) (xy 149.165 98.02224) (xy 149.197089 98.18356) (xy 149.260033 98.335521) + (xy 149.351413 98.472281) (xy 149.467719 98.588587) (xy 149.604479 98.679967) (xy 149.75644 98.742911) (xy 149.91776 98.775) + (xy 150.08224 98.775) (xy 150.24356 98.742911) (xy 150.395521 98.679967) (xy 150.532281 98.588587) (xy 150.648587 98.472281) + (xy 150.739967 98.335521) (xy 150.802911 98.18356) (xy 150.835 98.02224) (xy 150.835 97.966018) (xy 150.926185 97.891185) + (xy 151.005537 97.794494) (xy 151.064502 97.68418) (xy 151.100812 97.564482) (xy 151.113072 97.44) (xy 151.113072 96.14) + (xy 151.100812 96.015518) (xy 151.064502 95.89582) (xy 151.005537 95.785506) (xy 150.926185 95.688815) (xy 150.829494 95.609463) + (xy 150.76 95.572317) (xy 150.76 94.459601) (xy 151.546402 93.6732) (xy 154.487453 93.6732) (xy 154.524775 93.676876) + (xy 154.562097 93.6732) (xy 154.562108 93.6732) (xy 154.673761 93.662203) (xy 154.817022 93.618746) (xy 154.949051 93.548174) + (xy 154.969378 93.531492) (xy 155.004479 93.554946) (xy 155.108077 93.597858) (xy 155.440001 93.929782) (xy 155.440001 94.676928) + (xy 155.4 94.676928) (xy 155.275518 94.689188) (xy 155.15582 94.725498) (xy 155.045506 94.784463) (xy 154.948815 94.863815) + (xy 154.869463 94.960506) (xy 154.810498 95.07082) (xy 154.774188 95.190518) (xy 154.761928 95.315) (xy 154.761928 95.705) + (xy 154.66776 95.705) (xy 154.50644 95.737089) (xy 154.457685 95.757284) (xy 154.378817 95.661183) (xy 154.244059 95.550589) + (xy 154.090313 95.468411) (xy 153.92349 95.417805) (xy 153.75 95.400718) (xy 153.576511 95.417805) (xy 153.409688 95.468411) + (xy 153.255942 95.550589) (xy 153.121183 95.661183) (xy 153.010589 95.795941) (xy 152.928411 95.949687) (xy 152.877805 96.11651) + (xy 152.865 96.246523) (xy 152.865 96.458533) (xy 152.860719 96.502002) (xy 152.865 96.545471) (xy 152.865 96.545478) + (xy 152.875085 96.647877) (xy 152.877805 96.675492) (xy 152.884989 96.699173) (xy 152.928411 96.842314) (xy 153.010589 96.99606) + (xy 153.121183 97.130819) (xy 153.154956 97.158536) (xy 154.156468 98.160049) (xy 154.184181 98.193817) (xy 154.217949 98.22153) + (xy 154.217951 98.221532) (xy 154.262088 98.257754) (xy 154.318939 98.304411) (xy 154.472685 98.386589) (xy 154.639508 98.437195) + (xy 154.769521 98.45) (xy 154.769531 98.45) (xy 154.812997 98.454281) (xy 154.856463 98.45) (xy 154.894499 98.45) + (xy 154.948815 98.516185) (xy 155.045506 98.595537) (xy 155.15582 98.654502) (xy 155.275518 98.690812) (xy 155.315001 98.694701) + (xy 155.315001 99.101521) (xy 155.310719 99.145) (xy 155.327805 99.31849) (xy 155.378412 99.485313) (xy 155.46059 99.639059) + (xy 155.543468 99.740046) (xy 155.543471 99.740049) (xy 155.571184 99.773817) (xy 155.604952 99.80153) (xy 155.938466 100.135044) + (xy 155.966183 100.168817) (xy 156.100941 100.279411) (xy 156.254687 100.361589) (xy 156.42151 100.412195) (xy 156.551523 100.425) + (xy 156.551533 100.425) (xy 156.566374 100.426462) (xy 156.514424 100.478412) (xy 156.220583 100.918175) (xy 156.018183 101.406814) + (xy 155.915 101.925551) (xy 155.915 102.454449) (xy 156.018183 102.973186) (xy 156.023749 102.986623) (xy 155.801302 102.837989) + (xy 155.492012 102.709877) (xy 155.527932 102.623158) (xy 155.585 102.33626) (xy 155.585 102.04374) (xy 155.527932 101.756842) + (xy 155.41599 101.486589) (xy 155.253475 101.243368) (xy 155.046632 101.036525) (xy 154.803411 100.87401) (xy 154.533158 100.762068) + (xy 154.24626 100.705) (xy 154.076697 100.705) (xy 153.982327 100.665911) (xy 153.676109 100.605) (xy 153.363891 100.605) + (xy 153.057673 100.665911) (xy 152.769221 100.785391) (xy 152.509621 100.95885) (xy 152.28885 101.179621) (xy 152.115391 101.439221) + (xy 151.995911 101.727673) (xy 151.935 102.033891) (xy 151.935 102.346109) (xy 151.995911 102.652327) (xy 152.115391 102.940779) + (xy 152.28885 103.200379) (xy 152.509621 103.42115) (xy 152.769221 103.594609) (xy 152.935016 103.663283) (xy 152.897988 103.718699) + (xy 152.737047 104.107245) (xy 152.655 104.519722) (xy 152.655 104.94028) (xy 152.737047 105.352757) (xy 152.869252 105.671928) + (xy 151.75 105.671928) (xy 151.66 105.680792) (xy 151.66 101.277322) (xy 151.663676 101.239999) (xy 151.66 101.202676) + (xy 151.66 101.202667) (xy 151.649003 101.091014) (xy 151.605546 100.947753) (xy 151.534974 100.815724) (xy 151.440001 100.699999) + (xy 151.411003 100.676201) (xy 151.113072 100.37827) (xy 151.113072 99.69) (xy 151.100812 99.565518) (xy 151.064502 99.44582) + (xy 151.005537 99.335506) (xy 150.926185 99.238815) (xy 150.829494 99.159463) (xy 150.71918 99.100498) (xy 150.599482 99.064188) + (xy 150.475 99.051928) (xy 149.525 99.051928) (xy 149.400518 99.064188) (xy 149.28082 99.100498) (xy 149.170506 99.159463) + (xy 149.073815 99.238815) (xy 148.994463 99.335506) (xy 148.935498 99.44582) (xy 148.899188 99.565518) (xy 148.886928 99.69) + (xy 148.886928 100.99) (xy 148.899188 101.114482) (xy 148.935498 101.23418) (xy 148.994463 101.344494) (xy 149.073815 101.441185) + (xy 149.170506 101.520537) (xy 149.28082 101.579502) (xy 149.400518 101.615812) (xy 149.525 101.628072) (xy 150.140001 101.628072) + (xy 150.14 106.192843) (xy 150.097089 106.29644) (xy 150.065 106.45776) (xy 150.065 106.62224) (xy 150.097089 106.78356) + (xy 150.140001 106.887159) (xy 150.14 109.302679) (xy 150.136324 109.340002) (xy 150.14 109.377324) (xy 150.14 109.377334) + (xy 150.150997 109.488987) (xy 150.179297 109.582281) (xy 150.194454 109.632248) (xy 150.265026 109.764278) (xy 150.295009 109.800812) + (xy 150.359999 109.880003) (xy 150.389002 109.903805) (xy 151.061204 110.576009) (xy 151.084998 110.605002) (xy 151.113991 110.628796) + (xy 151.113995 110.6288) (xy 151.175187 110.679018) (xy 151.200723 110.699975) (xy 151.332752 110.770547) (xy 151.476013 110.814004) + (xy 151.587666 110.825001) (xy 151.587675 110.825001) (xy 151.624998 110.828677) (xy 151.662321 110.825001) (xy 164.587677 110.825001) + (xy 164.624999 110.828677) (xy 164.662321 110.825001) (xy 164.662332 110.825001) (xy 164.773985 110.814004) (xy 164.917246 110.770547) + (xy 165.049275 110.699975) (xy 165.165 110.605002) (xy 165.188803 110.575999) (xy 166.111003 109.653799) (xy 166.140001 109.630001) + (xy 166.234974 109.514276) (xy 166.305546 109.382247) (xy 166.349003 109.238986) (xy 166.36 109.127333) (xy 166.36 109.127325) + (xy 166.363676 109.09) (xy 166.36 109.052675) (xy 166.36 106.408072) (xy 166.75 106.408072) (xy 166.874482 106.395812) + (xy 166.99418 106.359502) (xy 167.104494 106.300537) (xy 167.201185 106.221185) (xy 167.280537 106.124494) (xy 167.339502 106.01418) + (xy 167.375812 105.894482) (xy 167.388072 105.77) (xy 167.388072 103.77) (xy 167.375812 103.645518) (xy 167.339502 103.52582) + (xy 167.280537 103.415506) (xy 167.201185 103.318815) (xy 167.104494 103.239463) (xy 166.99418 103.180498) (xy 166.874482 103.144188) + (xy 166.75 103.131928) (xy 164.956887 103.131928) (xy 165.084609 102.940779) (xy 165.204089 102.652327) (xy 165.265 102.346109) + (xy 165.265 102.033891) (xy 165.204089 101.727673) (xy 165.084609 101.439221) (xy 164.91115 101.179621) (xy 164.690379 100.95885) + (xy 164.430779 100.785391) (xy 164.142327 100.665911) (xy 163.836109 100.605) (xy 163.523891 100.605) (xy 163.217673 100.665911) + (xy 163.123303 100.705) (xy 162.95374 100.705) (xy 162.666842 100.762068) (xy 162.396589 100.87401) (xy 162.153368 101.036525) + (xy 161.946525 101.243368) (xy 161.78401 101.486589) (xy 161.672068 101.756842) (xy 161.615 102.04374) (xy 161.615 102.33626) + (xy 161.672068 102.623158) (xy 161.707988 102.709876) (xy 161.398698 102.837988) (xy 161.176252 102.986622) (xy 161.181817 102.973186) + (xy 161.285 102.454449) (xy 161.285 101.925551) (xy 161.181817 101.406814) (xy 160.979417 100.918175) (xy 160.685576 100.478412) + (xy 160.632164 100.425) (xy 165.556511 100.425) (xy 165.59998 100.429281) (xy 165.643449 100.425) (xy 165.643457 100.425) + (xy 165.77347 100.412195) (xy 165.940293 100.361589) (xy 166.094039 100.279411) (xy 166.228797 100.168817) (xy 166.256514 100.135044) + (xy 167.081522 99.310037) (xy 167.1644 99.20905) (xy 167.246578 99.055304) (xy 167.297184 98.888481) (xy 167.314271 98.714991) + (xy 167.297184 98.541501) (xy 167.246578 98.374677) (xy 167.1644 98.220932) (xy 167.053807 98.086173) (xy 166.919048 97.97558) + (xy 166.765303 97.893402) (xy 166.598479 97.842796) (xy 166.424989 97.825709) (xy 166.251499 97.842796) (xy 166.084676 97.893402) + (xy 165.93093 97.97558) (xy 165.829943 98.058458) (xy 165.233402 98.655) (xy 162.042538 98.655) (xy 162.04418 98.654502) + (xy 162.154494 98.595537) (xy 162.251185 98.516185) (xy 162.330537 98.419494) (xy 162.381046 98.325) (xy 162.687678 98.325) + (xy 162.725 98.328676) (xy 162.762322 98.325) (xy 162.762333 98.325) (xy 162.873986 98.314003) (xy 163.017247 98.270546) + (xy 163.149276 98.199974) (xy 163.265001 98.105001) (xy 163.288803 98.075998) (xy 163.811004 97.553798) (xy 163.840001 97.530001) + (xy 163.934974 97.414276) (xy 164.005546 97.282247) (xy 164.049003 97.138986) (xy 164.06 97.027333) (xy 164.06 97.027325) + (xy 164.063676 96.99) (xy 164.06 96.952675) (xy 164.06 96.014134) (xy 164.063676 95.976812) (xy 164.06 95.939489) + (xy 164.06 95.939479) (xy 164.049003 95.827826) (xy 164.005546 95.684565) (xy 163.987725 95.651224) (xy 163.934974 95.552535) + (xy 163.863799 95.465809) (xy 163.840001 95.436811) (xy 163.811003 95.413013) (xy 162.576992 94.179003) (xy 162.553189 94.149999) + (xy 162.437464 94.055026) (xy 162.305435 93.984454) (xy 162.162174 93.940997) (xy 162.050521 93.93) (xy 162.05051 93.93) + (xy 162.013188 93.926324) (xy 161.975866 93.93) (xy 161.797157 93.93) (xy 161.69356 93.887089) (xy 161.53224 93.855) + (xy 161.36776 93.855) (xy 161.20644 93.887089) (xy 161.054479 93.950033) (xy 160.937873 94.027946) (xy 160.854475 93.926325) + (xy 160.746363 93.8376) (xy 160.62302 93.771672) (xy 160.489184 93.731073) (xy 160.384877 93.7208) (xy 160.35 93.717365) + (xy 160.315123 93.7208) (xy 156.96 93.7208) (xy 156.96 93.652302) (xy 156.963676 93.614979) (xy 156.96 93.577656) + (xy 156.96 93.577646) (xy 156.949003 93.465993) (xy 156.905546 93.322732) (xy 156.834974 93.190703) (xy 156.740001 93.074978) + (xy 156.711002 93.05118) (xy 156.7098 93.049977) (xy 163.935176 93.049977) (xy 165.5462 94.661002) (xy 165.57 94.690002) + (xy 165.685725 94.784975) (xy 165.817754 94.855547) (xy 165.961015 94.899004) (xy 166.072668 94.910001) (xy 166.072677 94.910001) + (xy 166.11 94.913677) (xy 166.147323 94.910001) (xy 168.490001 94.910001) (xy 168.49 98.552843) (xy 168.447089 98.65644) + (xy 168.415 98.81776) (xy 168.415 98.98224) (xy 168.447089 99.14356) (xy 168.459533 99.173602) (xy 168.420506 99.194463) + (xy 168.323815 99.273815) (xy 168.244463 99.370506) (xy 168.185498 99.48082) (xy 168.149188 99.600518) (xy 168.136928 99.725) + (xy 168.136928 101.025) (xy 168.149188 101.149482) (xy 168.185498 101.26918) (xy 168.244463 101.379494) (xy 168.323815 101.476185) + (xy 168.420506 101.555537) (xy 168.53082 101.614502) (xy 168.650518 101.650812) (xy 168.775 101.663072) (xy 169.725 101.663072) + (xy 169.849482 101.650812) (xy 169.96918 101.614502) (xy 170.079494 101.555537) (xy 170.176185 101.476185) (xy 170.255537 101.379494) + (xy 170.314502 101.26918) (xy 170.350812 101.149482) (xy 170.363072 101.025) (xy 170.363072 99.725) (xy 170.350812 99.600518) + (xy 170.314502 99.48082) (xy 170.255537 99.370506) (xy 170.176185 99.273815) (xy 170.079494 99.194463) (xy 170.040467 99.173602) + (xy 170.052911 99.14356) (xy 170.085 98.98224) (xy 170.085 98.81776) (xy 170.052911 98.65644) (xy 170.01 98.552843) + (xy 170.01 95.51) (xy 170.08224 95.51) (xy 170.24356 95.477911) (xy 170.395521 95.414967) (xy 170.402955 95.41) + (xy 181.185199 95.41) (xy 182.649602 96.874404) (xy 182.6734 96.903402) (xy 182.702398 96.9272) (xy 182.789124 96.998375) + (xy 182.857706 97.035033) (xy 182.921154 97.068947) (xy 183.064415 97.112404) (xy 183.176068 97.123401) (xy 183.176078 97.123401) + (xy 183.213401 97.127077) (xy 183.250724 97.123401) (xy 185.127842 97.123401) (xy 185.231439 97.166312) (xy 185.392759 97.198401) + (xy 185.557239 97.198401) (xy 185.718559 97.166312) (xy 185.87052 97.103368) (xy 186.00728 97.011988) (xy 186.123586 96.895682) + (xy 186.214966 96.758922) (xy 186.27791 96.606961) (xy 186.309999 96.445641) (xy 186.309999 96.281161) (xy 186.27791 96.119841) + (xy 186.214966 95.96788) (xy 186.123586 95.83112) (xy 186.00728 95.714814) (xy 185.87052 95.623434) (xy 185.718559 95.56049) + (xy 185.557239 95.528401) (xy 185.392759 95.528401) (xy 185.231439 95.56049) (xy 185.127842 95.603401) (xy 183.528203 95.603401) + (xy 183.061957 95.137155) (xy 183.101014 95.149003) (xy 183.212667 95.16) (xy 183.212676 95.16) (xy 183.249999 95.163676) + (xy 183.287322 95.16) (xy 185.652843 95.16) (xy 185.75644 95.202911) (xy 185.91776 95.235) (xy 186.08224 95.235) + (xy 186.24356 95.202911) (xy 186.395521 95.139967) (xy 186.532281 95.048587) (xy 186.648587 94.932281) (xy 186.739967 94.795521) + (xy 186.802911 94.64356) (xy 186.835 94.48224) (xy 186.835 94.31776) (xy 186.802911 94.15644) (xy 186.739967 94.004479) + (xy 186.648587 93.867719) (xy 186.532281 93.751413) (xy 186.395521 93.660033) (xy 186.24356 93.597089) (xy 186.08224 93.565) + (xy 185.91776 93.565) (xy 185.75644 93.597089) (xy 185.652843 93.64) (xy 184.534801 93.64) (xy 185.111003 93.063799) + (xy 185.140001 93.040001) (xy 185.234974 92.924276) (xy 185.305546 92.792247) (xy 185.349003 92.648986) (xy 185.36 92.537333) + (xy 185.36 92.537325) (xy 185.363676 92.5) (xy 185.36 92.462675) (xy 185.36 89.9) (xy 187.386928 89.9) + (xy 187.386928 91.2) (xy 187.399188 91.324482) (xy 187.435498 91.44418) (xy 187.494463 91.554494) (xy 187.573815 91.651185) + (xy 187.665 91.726018) (xy 187.665 91.83224) (xy 187.697089 91.99356) (xy 187.760033 92.145521) (xy 187.851413 92.282281) + (xy 187.967719 92.398587) (xy 188.104479 92.489967) (xy 188.25644 92.552911) (xy 188.41776 92.585) (xy 188.58224 92.585) + (xy 188.74356 92.552911) (xy 188.895521 92.489967) (xy 189.032281 92.398587) (xy 189.148587 92.282281) (xy 189.239967 92.145521) + (xy 189.302911 91.99356) (xy 189.335 91.83224) (xy 189.335 91.726018) (xy 189.426185 91.651185) (xy 189.505537 91.554494) + (xy 189.564502 91.44418) (xy 189.600812 91.324482) (xy 189.613072 91.2) (xy 189.613072 89.9) (xy 189.600812 89.775518) + (xy 189.564502 89.65582) (xy 189.505537 89.545506) (xy 189.426185 89.448815) (xy 189.329494 89.369463) (xy 189.21918 89.310498) + (xy 189.099482 89.274188) (xy 188.975 89.261928) (xy 188.025 89.261928) (xy 187.900518 89.274188) (xy 187.78082 89.310498) + (xy 187.670506 89.369463) (xy 187.573815 89.448815) (xy 187.494463 89.545506) (xy 187.435498 89.65582) (xy 187.399188 89.775518) + (xy 187.386928 89.9) (xy 185.36 89.9) (xy 185.36 89.818072) (xy 185.75 89.818072) (xy 185.874482 89.805812) + (xy 185.99418 89.769502) (xy 186.104494 89.710537) (xy 186.201185 89.631185) (xy 186.280537 89.534494) (xy 186.339502 89.42418) + (xy 186.375812 89.304482) (xy 186.388072 89.18) (xy 186.388072 87.18) (xy 186.375812 87.055518) (xy 186.339502 86.93582) + (xy 186.280537 86.825506) (xy 186.201185 86.728815) (xy 186.104494 86.649463) (xy 185.99418 86.590498) (xy 185.874482 86.554188) + (xy 185.75 86.541928) (xy 183.956887 86.541928) (xy 184.084609 86.350779) (xy 184.204089 86.062327) (xy 184.265 85.756109) + (xy 184.265 85.443891) (xy 184.204089 85.137673) (xy 184.084609 84.849221) (xy 183.91115 84.589621) (xy 183.690379 84.36885) + (xy 183.430779 84.195391) (xy 183.142327 84.075911) (xy 182.836109 84.015) (xy 182.523891 84.015) (xy 182.217673 84.075911) + (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) (xy 181.153368 84.446525) + (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) (xy 180.615 85.74626) + (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) (xy 180.181817 86.383186) + (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) (xy 179.685576 83.888412) + (xy 179.457164 83.66) (xy 183.789324 83.66) (xy 183.90644 83.708511) (xy 184.06776 83.7406) (xy 184.23224 83.7406) + (xy 184.39356 83.708511) (xy 184.545521 83.645567) (xy 184.682281 83.554187) (xy 184.798587 83.437881) (xy 184.889967 83.301121) + (xy 184.952911 83.14916) (xy 184.985 82.98784) (xy 184.985 82.82336) (xy 185.1946 82.82336) (xy 185.1946 82.98784) + (xy 185.226689 83.14916) (xy 185.289633 83.301121) (xy 185.381013 83.437881) (xy 185.497319 83.554187) (xy 185.634079 83.645567) + (xy 185.737678 83.688479) (xy 187.74 85.690802) (xy 187.74 85.782317) (xy 187.670506 85.819463) (xy 187.573815 85.898815) + (xy 187.494463 85.995506) (xy 187.435498 86.10582) (xy 187.399188 86.225518) (xy 187.386928 86.35) (xy 187.386928 87.65) + (xy 187.399188 87.774482) (xy 187.435498 87.89418) (xy 187.494463 88.004494) (xy 187.573815 88.101185) (xy 187.665 88.176018) + (xy 187.665 88.33224) (xy 187.697089 88.49356) (xy 187.760033 88.645521) (xy 187.851413 88.782281) (xy 187.967719 88.898587) + (xy 188.104479 88.989967) (xy 188.25644 89.052911) (xy 188.41776 89.085) (xy 188.58224 89.085) (xy 188.74356 89.052911) + (xy 188.895521 88.989967) (xy 189.032281 88.898587) (xy 189.148587 88.782281) (xy 189.239967 88.645521) (xy 189.302911 88.49356) + (xy 189.335 88.33224) (xy 189.335 88.176018) (xy 189.426185 88.101185) (xy 189.505537 88.004494) (xy 189.564502 87.89418) + (xy 189.600812 87.774482) (xy 189.613072 87.65) (xy 189.613072 86.35) (xy 189.600812 86.225518) (xy 189.564502 86.10582) + (xy 189.505537 85.995506) (xy 189.426185 85.898815) (xy 189.329494 85.819463) (xy 189.26 85.782317) (xy 189.26 85.413322) + (xy 189.263676 85.375999) (xy 189.26 85.338676) (xy 189.26 85.338667) (xy 189.249003 85.227014) (xy 189.205546 85.083753) + (xy 189.134974 84.951724) (xy 189.040001 84.835999) (xy 189.011004 84.812202) (xy 186.812479 82.613678) (xy 186.769567 82.510079) + (xy 186.678187 82.373319) (xy 186.561881 82.257013) (xy 186.425121 82.165633) (xy 186.27316 82.102689) (xy 186.11184 82.0706) + (xy 185.94736 82.0706) (xy 185.78604 82.102689) (xy 185.634079 82.165633) (xy 185.497319 82.257013) (xy 185.381013 82.373319) + (xy 185.289633 82.510079) (xy 185.226689 82.66204) (xy 185.1946 82.82336) (xy 184.985 82.82336) (xy 184.952911 82.66204) + (xy 184.889967 82.510079) (xy 184.798587 82.373319) (xy 184.682281 82.257013) (xy 184.545521 82.165633) (xy 184.39356 82.102689) + (xy 184.23224 82.0706) (xy 184.06776 82.0706) (xy 183.90644 82.102689) (xy 183.816363 82.14) (xy 180.06 82.14) + (xy 180.06 82.113072) (xy 180.8 82.113072) (xy 180.924482 82.100812) (xy 181.04418 82.064502) (xy 181.154494 82.005537) + (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) (xy 181.425812 81.599482) (xy 181.431418 81.542562) + (xy 181.465001 81.515001) (xy 181.488803 81.485998) (xy 181.891923 81.082878) (xy 181.995521 81.039967) (xy 182.132281 80.948587) + (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) (xy 182.435 80.21776) + (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) (xy 181.995521 79.560033) + (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.51776 79.465) (xy 181.410571 79.486321) (xy 181.27625 79.352) + (xy 180.127 79.352) (xy 180.127 79.372) (xy 180.06 79.372) (xy 180.06 79.078) (xy 180.127 79.078) + (xy 180.127 79.098) (xy 181.27625 79.098) (xy 181.435 78.93925) (xy 181.438072 78.725) (xy 181.425812 78.600518) + (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) (xy 181.154494 78.194463) (xy 181.04418 78.135498) + (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.28575 78.09) (xy 180.127002 78.248748) (xy 180.127002 78.09) + (xy 180.06 78.09) (xy 180.06 77.984877) (xy 180.063435 77.95) (xy 180.049727 77.810816) (xy 180.009128 77.67698) + (xy 179.9432 77.553637) (xy 179.854475 77.445525) (xy 179.746363 77.3568) (xy 179.62302 77.290872) (xy 179.489184 77.250273) + (xy 179.384877 77.24) (xy 179.35 77.236565) (xy 179.315123 77.24) (xy 175.884877 77.24) (xy 175.85 77.236565) + (xy 175.815123 77.24) (xy 175.710816 77.250273) (xy 175.57698 77.290872) (xy 175.453637 77.3568) (xy 175.345525 77.445525) + (xy 175.2568 77.553637) (xy 175.190872 77.67698) (xy 175.150273 77.810816) (xy 175.136565 77.95) (xy 175.140001 77.984887) + (xy 175.140001 78.086928) (xy 174.4 78.086928) (xy 174.275518 78.099188) (xy 174.15582 78.135498) (xy 174.045506 78.194463) + (xy 173.948815 78.273815) (xy 173.869463 78.370506) (xy 173.810498 78.48082) (xy 173.806686 78.493387) (xy 173.720753 78.519454) + (xy 173.588724 78.590026) (xy 173.472999 78.684999) (xy 173.4492 78.713998) (xy 172.989002 79.174197) (xy 172.959999 79.197999) + (xy 172.916164 79.251413) (xy 172.865026 79.313724) (xy 172.80849 79.419494) (xy 172.794454 79.445754) (xy 172.750997 79.589015) + (xy 172.74 79.700668) (xy 172.74 79.700678) (xy 172.736324 79.738) (xy 172.74 79.775322) (xy 172.74 80.002841) + (xy 172.697089 80.106438) (xy 172.665 80.267758) (xy 172.665 80.432238) (xy 172.673412 80.474526) (xy 172.605941 80.510589) + (xy 172.471183 80.621183) (xy 172.360589 80.755941) (xy 172.278411 80.909687) (xy 172.269919 80.937681) (xy 172.148986 80.900997) + (xy 172.037333 80.89) (xy 172.037322 80.89) (xy 172 80.886324) (xy 171.962678 80.89) (xy 170.827238 80.89) + (xy 170.825812 80.875518) (xy 170.789502 80.75582) (xy 170.730537 80.645506) (xy 170.651185 80.548815) (xy 170.554494 80.469463) + (xy 170.44418 80.410498) (xy 170.324482 80.374188) (xy 170.2 80.361928) (xy 169.25 80.361928) (xy 169.125518 80.374188) + (xy 169.00582 80.410498) (xy 168.895506 80.469463) (xy 168.798815 80.548815) (xy 168.719463 80.645506) (xy 168.660498 80.75582) + (xy 168.624188 80.875518) (xy 168.611928 81) (xy 168.611928 82.3) (xy 168.624188 82.424482) (xy 168.660498 82.54418) + (xy 168.719463 82.654494) (xy 168.798815 82.751185) (xy 168.895506 82.830537) (xy 169.00582 82.889502) (xy 169.125518 82.925812) + (xy 169.25 82.938072) (xy 170.2 82.938072) (xy 170.324482 82.925812) (xy 170.44418 82.889502) (xy 170.554494 82.830537) + (xy 170.651185 82.751185) (xy 170.730537 82.654494) (xy 170.789502 82.54418) (xy 170.825812 82.424482) (xy 170.827238 82.41) + (xy 171.685199 82.41) (xy 172.6862 83.411002) (xy 172.709999 83.440001) (xy 172.738997 83.463799) (xy 172.825723 83.534974) + (xy 172.914151 83.58224) (xy 172.957753 83.605546) (xy 173.101014 83.649003) (xy 173.212667 83.66) (xy 173.212677 83.66) + (xy 173.25 83.663676) (xy 173.287323 83.66) (xy 174.445386 83.66) (xy 174.447089 83.66856) (xy 174.510033 83.820521) + (xy 174.601413 83.957281) (xy 174.717719 84.073587) (xy 174.854479 84.164967) (xy 175.00644 84.227911) (xy 175.16776 84.26) + (xy 175.266136 84.26) (xy 175.220583 84.328175) (xy 175.018183 84.816814) (xy 174.915 85.335551) (xy 174.915 85.864449) + (xy 175.018183 86.383186) (xy 175.023749 86.396623) (xy 174.801302 86.247989) (xy 174.492012 86.119877) (xy 174.527932 86.033158) + (xy 174.585 85.74626) (xy 174.585 85.45374) (xy 174.527932 85.166842) (xy 174.41599 84.896589) (xy 174.253475 84.653368) + (xy 174.046632 84.446525) (xy 173.803411 84.28401) (xy 173.533158 84.172068) (xy 173.24626 84.115) (xy 173.076697 84.115) + (xy 172.982327 84.075911) (xy 172.676109 84.015) (xy 172.363891 84.015) (xy 172.057673 84.075911) (xy 171.769221 84.195391) + (xy 171.509621 84.36885) (xy 171.28885 84.589621) (xy 171.115391 84.849221) (xy 170.995911 85.137673) (xy 170.935 85.443891) + (xy 170.935 85.756109) (xy 170.995911 86.062327) (xy 171.115391 86.350779) (xy 171.28885 86.610379) (xy 171.509621 86.83115) + (xy 171.769221 87.004609) (xy 171.935016 87.073283) (xy 171.897988 87.128699) (xy 171.737047 87.517245) (xy 171.655 87.929722) + (xy 171.655 88.35028) (xy 171.737047 88.762757) (xy 171.869252 89.081928) (xy 170.75 89.081928) (xy 170.625518 89.094188) + (xy 170.50582 89.130498) (xy 170.395506 89.189463) (xy 170.336818 89.237627) (xy 170.295521 89.210033) (xy 170.14356 89.147089) + (xy 169.98224 89.115) (xy 169.81776 89.115) (xy 169.65644 89.147089) (xy 169.504479 89.210033) (xy 169.367719 89.301413) + (xy 169.251413 89.417719) (xy 169.160033 89.554479) (xy 169.097089 89.70644) (xy 169.065 89.86776) (xy 169.065 90.03224) + (xy 169.097089 90.19356) (xy 169.140001 90.297159) (xy 169.14 92.712679) (xy 169.136324 92.750002) (xy 169.14 92.787324) + (xy 169.14 92.787334) (xy 169.149912 92.887967) (xy 169.145521 92.885033) (xy 168.99356 92.822089) (xy 168.83224 92.79) + (xy 168.66776 92.79) (xy 168.50644 92.822089) (xy 168.402843 92.865) (xy 166.599802 92.865) (xy 165.249801 91.515) + (xy 166.011003 90.753799) (xy 166.040001 90.730001) (xy 166.134974 90.614276) (xy 166.205546 90.482247) (xy 166.249003 90.338986) + (xy 166.26 90.227333) (xy 166.26 90.227325) (xy 166.263676 90.19) (xy 166.26 90.152675) (xy 166.26 87.408072) + (xy 166.440001 87.408072) (xy 166.440001 91.758477) (xy 166.452806 91.88849) (xy 166.503412 92.055313) (xy 166.58559 92.209059) + (xy 166.696184 92.343817) (xy 166.830942 92.454411) (xy 166.984688 92.536589) (xy 167.151511 92.587195) (xy 167.325 92.604282) + (xy 167.49849 92.587195) (xy 167.665313 92.536589) (xy 167.819059 92.454411) (xy 167.953817 92.343817) (xy 168.064411 92.209059) + (xy 168.146589 92.055313) (xy 168.197195 91.88849) (xy 168.21 91.758477) (xy 168.21 84.55) (xy 168.611928 84.55) + (xy 168.611928 85.85) (xy 168.624188 85.974482) (xy 168.660498 86.09418) (xy 168.719463 86.204494) (xy 168.798815 86.301185) + (xy 168.895506 86.380537) (xy 168.946789 86.407949) (xy 168.915 86.56776) (xy 168.915 86.73224) (xy 168.947089 86.89356) + (xy 169.010033 87.045521) (xy 169.101413 87.182281) (xy 169.217719 87.298587) (xy 169.354479 87.389967) (xy 169.50644 87.452911) + (xy 169.66776 87.485) (xy 169.83224 87.485) (xy 169.99356 87.452911) (xy 170.145521 87.389967) (xy 170.282281 87.298587) + (xy 170.398587 87.182281) (xy 170.489967 87.045521) (xy 170.552911 86.89356) (xy 170.585 86.73224) (xy 170.585 86.56776) + (xy 170.552911 86.40644) (xy 170.544414 86.385925) (xy 170.554494 86.380537) (xy 170.651185 86.301185) (xy 170.730537 86.204494) + (xy 170.789502 86.09418) (xy 170.825812 85.974482) (xy 170.838072 85.85) (xy 170.838072 84.55) (xy 170.825812 84.425518) + (xy 170.789502 84.30582) (xy 170.730537 84.195506) (xy 170.651185 84.098815) (xy 170.554494 84.019463) (xy 170.44418 83.960498) + (xy 170.324482 83.924188) (xy 170.2 83.911928) (xy 169.25 83.911928) (xy 169.125518 83.924188) (xy 169.00582 83.960498) + (xy 168.895506 84.019463) (xy 168.798815 84.098815) (xy 168.719463 84.195506) (xy 168.660498 84.30582) (xy 168.624188 84.425518) + (xy 168.611928 84.55) (xy 168.21 84.55) (xy 168.21 78.158466) (xy 168.214281 78.114999) (xy 168.21 78.071533) + (xy 168.21 78.071523) (xy 168.197195 77.94151) (xy 168.146589 77.774687) (xy 168.135 77.753005) (xy 168.135 65.463078) + (xy 168.386928 65.21115) (xy 168.386928 66.075) (xy 168.399188 66.199482) (xy 168.435498 66.31918) (xy 168.494463 66.429494) + (xy 168.573815 66.526185) (xy 168.670506 66.605537) (xy 168.78082 66.664502) (xy 168.900518 66.700812) (xy 169.025 66.713072) + (xy 169.708204 66.713072) (xy 169.747533 66.808021) (xy 169.838913 66.944781) (xy 169.955219 67.061087) (xy 170.091979 67.152467) + (xy 170.24394 67.215411) (xy 170.40526 67.2475) (xy 170.56974 67.2475) (xy 170.73106 67.215411) (xy 170.883021 67.152467) + (xy 171.019781 67.061087) (xy 171.031828 67.04904) (xy 171.115391 67.250779) (xy 171.28885 67.510379) (xy 171.509621 67.73115) + (xy 171.769221 67.904609) (xy 171.935016 67.973283) (xy 171.897988 68.028699) (xy 171.737047 68.417245) (xy 171.655 68.829722) + (xy 171.655 69.25028) (xy 171.737047 69.662757) (xy 171.869252 69.981928) (xy 170.75 69.981928) (xy 170.625518 69.994188) + (xy 170.50582 70.030498) (xy 170.395506 70.089463) (xy 170.336818 70.137627) (xy 170.295521 70.110033) (xy 170.14356 70.047089) + (xy 169.98224 70.015) (xy 169.81776 70.015) (xy 169.65644 70.047089) (xy 169.504479 70.110033) (xy 169.367719 70.201413) + (xy 169.251413 70.317719) (xy 169.160033 70.454479) (xy 169.097089 70.60644) (xy 169.065 70.76776) (xy 169.065 70.93224) + (xy 169.097089 71.09356) (xy 169.140001 71.197159) (xy 169.14 73.612679) (xy 169.136324 73.650002) (xy 169.14 73.687324) + (xy 169.14 73.687334) (xy 169.150997 73.798987) (xy 169.182907 73.904181) (xy 169.194454 73.942248) (xy 169.265026 74.074278) + (xy 169.297792 74.114203) (xy 169.359999 74.190003) (xy 169.389002 74.213805) (xy 170.061204 74.886009) (xy 170.084998 74.915002) + (xy 170.113991 74.938796) (xy 170.113995 74.9388) (xy 170.170259 74.984974) (xy 170.200723 75.009975) (xy 170.332752 75.080547) + (xy 170.476013 75.124004) (xy 170.587666 75.135001) (xy 170.587675 75.135001) (xy 170.624998 75.138677) (xy 170.662321 75.135001) + (xy 183.587677 75.135001) (xy 183.624999 75.138677) (xy 183.662321 75.135001) (xy 183.662332 75.135001) (xy 183.773985 75.124004) + (xy 183.917246 75.080547) (xy 184.049275 75.009975) (xy 184.165 74.915002) (xy 184.188803 74.885999) (xy 185.111003 73.963799) + (xy 185.140001 73.940001) (xy 185.234974 73.824276) (xy 185.305546 73.692247) (xy 185.349003 73.548986) (xy 185.36 73.437333) + (xy 185.36 73.437325) (xy 185.363676 73.4) (xy 185.36 73.362675) (xy 185.36 70.718072) (xy 185.75 70.718072) + (xy 185.874482 70.705812) (xy 185.99418 70.669502) (xy 186.104494 70.610537) (xy 186.201185 70.531185) (xy 186.280537 70.434494) + (xy 186.339502 70.32418) (xy 186.375812 70.204482) (xy 186.388072 70.08) (xy 186.388072 68.08) (xy 186.375812 67.955518) + (xy 186.339502 67.83582) (xy 186.280537 67.725506) (xy 186.201185 67.628815) (xy 186.104494 67.549463) (xy 185.99418 67.490498) + (xy 185.874482 67.454188) (xy 185.75 67.441928) (xy 183.956887 67.441928) (xy 184.084609 67.250779) (xy 184.204089 66.962327) + (xy 184.265 66.656109) (xy 184.265 66.343891) (xy 184.204089 66.037673) (xy 184.084609 65.749221) (xy 183.91115 65.489621) + (xy 183.876199 65.45467) (xy 183.898587 65.432281) (xy 183.989967 65.295521) (xy 184.052911 65.14356) (xy 184.085 64.98224) + (xy 184.085 64.81776) (xy 184.052911 64.65644) (xy 183.989967 64.504479) (xy 183.898587 64.367719) (xy 183.782281 64.251413) + (xy 183.710011 64.203124) (xy 183.710011 61.47883) (xy 183.752922 61.375233) (xy 183.785011 61.213913) (xy 183.785011 61.049433) + (xy 183.752922 60.888113) (xy 183.689978 60.736152) (xy 183.598598 60.599392) (xy 183.482292 60.483086) (xy 183.345532 60.391706) + (xy 183.193571 60.328762) (xy 183.032251 60.296673) (xy 182.867771 60.296673) (xy 182.706451 60.328762) (xy 182.55449 60.391706) + (xy 182.41773 60.483086) (xy 182.301424 60.599392) (xy 182.260586 60.66051) (xy 182.198585 60.567719) (xy 182.082279 60.451413) + (xy 181.945519 60.360033) (xy 181.793558 60.297089) (xy 181.632238 60.265) (xy 181.467758 60.265) (xy 181.318867 60.294617) + (xy 181.27625 60.252) (xy 180.127 60.252) (xy 180.127 60.272) (xy 180.06 60.272) (xy 180.06 59.978) + (xy 180.127 59.978) (xy 180.127 59.998) (xy 181.27625 59.998) (xy 181.435 59.83925) (xy 181.438072 59.625) + (xy 181.425812 59.500518) (xy 181.389502 59.38082) (xy 181.330537 59.270506) (xy 181.251185 59.173815) (xy 181.154494 59.094463) + (xy 181.04418 59.035498) (xy 180.924482 58.999188) (xy 180.8 58.986928) (xy 180.28575 58.99) (xy 180.127002 59.148748) + (xy 180.127002 58.99) (xy 180.06 58.99) (xy 180.06 58.783277) (xy 180.063435 58.7484) (xy 180.049727 58.609216) + (xy 180.009128 58.47538) (xy 179.9432 58.352037) (xy 179.854475 58.243925) (xy 179.746363 58.1552) (xy 179.62302 58.089272) + (xy 179.489184 58.048673) (xy 179.384877 58.0384) (xy 179.35 58.034965) (xy 179.315123 58.0384) (xy 175.884877 58.0384) + (xy 175.85 58.034965) (xy 175.815123 58.0384) (xy 175.710816 58.048673) (xy 175.57698 58.089272) (xy 175.453637 58.1552) + (xy 175.345525 58.243925) (xy 175.2568 58.352037) (xy 175.190872 58.47538) (xy 175.150273 58.609216) (xy 175.136565 58.7484) + (xy 175.140001 58.783287) (xy 175.140001 58.986928) (xy 174.4 58.986928) (xy 174.275518 58.999188) (xy 174.15582 59.035498) + (xy 174.045506 59.094463) (xy 173.948815 59.173815) (xy 173.869463 59.270506) (xy 173.810498 59.38082) (xy 173.774188 59.500518) + (xy 173.761928 59.625) (xy 173.761928 59.91327) (xy 173.322722 60.352476) (xy 173.304479 60.360033) (xy 173.167719 60.451413) + (xy 173.051413 60.567719) (xy 172.960033 60.704479) (xy 172.897089 60.85644) (xy 172.870522 60.99) (xy 172.310001 60.99) + (xy 172.310001 60.47047) (xy 172.314282 60.427001) (xy 172.310001 60.383532) (xy 172.310001 60.383524) (xy 172.297196 60.253511) + (xy 172.24659 60.086688) (xy 172.164412 59.932942) (xy 172.122145 59.88144) (xy 172.081533 59.831954) (xy 172.081531 59.831952) + (xy 172.053818 59.798184) (xy 172.020051 59.770472) (xy 168.635 56.385422) (xy 168.635 53.833477) (xy 168.639282 53.79) + (xy 168.635 53.746523) (xy 168.635 48.471105) (xy 168.650518 48.475812) (xy 168.775 48.488072) (xy 169.725 48.488072) + (xy 169.849482 48.475812) (xy 169.934399 48.450053) (xy 169.934399 51.015) (xy 169.81776 51.015) (xy 169.65644 51.047089) + (xy 169.504479 51.110033) (xy 169.367719 51.201413) (xy 169.251413 51.317719) (xy 169.160033 51.454479) (xy 169.097089 51.60644) + (xy 169.065 51.76776) (xy 169.065 51.93224) (xy 169.097089 52.09356) (xy 169.140001 52.197159) (xy 169.14 54.612679) + (xy 169.136324 54.650002) (xy 169.14 54.687324) (xy 169.14 54.687334) (xy 169.150997 54.798987) (xy 169.184976 54.911003) + (xy 169.194454 54.942248) (xy 169.265026 55.074278) (xy 169.304871 55.122828) (xy 169.359999 55.190003) (xy 169.389002 55.213805) + (xy 170.061204 55.886009) (xy 170.084998 55.915002) (xy 170.113991 55.938796) (xy 170.113995 55.9388) (xy 170.175729 55.989463) + (xy 170.200723 56.009975) (xy 170.332752 56.080547) (xy 170.476013 56.124004) (xy 170.587666 56.135001) (xy 170.587675 56.135001) + (xy 170.624998 56.138677) (xy 170.662321 56.135001) (xy 183.587677 56.135001) (xy 183.624999 56.138677) (xy 183.662321 56.135001) + (xy 183.662332 56.135001) (xy 183.773985 56.124004) (xy 183.917246 56.080547) (xy 184.049275 56.009975) (xy 184.165 55.915002) + (xy 184.188803 55.885999) (xy 185.111004 54.963798) (xy 185.140001 54.940001) (xy 185.234974 54.824276) (xy 185.305546 54.692247) + (xy 185.349003 54.548986) (xy 185.36 54.437333) (xy 185.36 54.437325) (xy 185.363676 54.4) (xy 185.36 54.362675) + (xy 185.36 51.718072) (xy 185.75 51.718072) (xy 185.874482 51.705812) (xy 185.99418 51.669502) (xy 186.104494 51.610537) + (xy 186.201185 51.531185) (xy 186.280537 51.434494) (xy 186.339502 51.32418) (xy 186.375812 51.204482) (xy 186.388072 51.08) + (xy 186.388072 49.08) (xy 186.375812 48.955518) (xy 186.339502 48.83582) (xy 186.280537 48.725506) (xy 186.201185 48.628815) + (xy 186.104494 48.549463) (xy 185.99418 48.490498) (xy 185.874482 48.454188) (xy 185.75 48.441928) (xy 183.956887 48.441928) + (xy 184.084609 48.250779) (xy 184.204089 47.962327) (xy 184.265 47.656109) (xy 184.265 47.343891) (xy 184.204089 47.037673) + (xy 184.084609 46.749221) (xy 183.91115 46.489621) (xy 183.690379 46.26885) (xy 183.430779 46.095391) (xy 183.142327 45.975911) + (xy 182.836109 45.915) (xy 182.523891 45.915) (xy 182.217673 45.975911) (xy 182.123303 46.015) (xy 181.95374 46.015) + (xy 181.666842 46.072068) (xy 181.396589 46.18401) (xy 181.153368 46.346525) (xy 180.946525 46.553368) (xy 180.78401 46.796589) + (xy 180.672068 47.066842) (xy 180.615 47.35374) (xy 180.615 47.64626) (xy 180.672068 47.933158) (xy 180.707988 48.019876) + (xy 180.398698 48.147988) (xy 180.176252 48.296622) (xy 180.181817 48.283186) (xy 180.285 47.764449) (xy 180.285 47.235551) + (xy 180.181817 46.716814) (xy 179.979417 46.228175) (xy 179.685576 45.788412) (xy 179.657164 45.76) (xy 179.812677 45.76) + (xy 179.849999 45.763676) (xy 179.887321 45.76) (xy 179.887332 45.76) (xy 179.998985 45.749003) (xy 180.142246 45.705546) + (xy 180.274275 45.634974) (xy 180.39 45.540001) (xy 180.413803 45.510997) (xy 180.541922 45.382878) (xy 180.645521 45.339966) + (xy 180.782281 45.248586) (xy 180.898587 45.13228) (xy 180.989967 44.99552) (xy 181.052911 44.843559) (xy 181.085 44.682239) + (xy 181.085 44.517759) (xy 181.052911 44.356439) (xy 181.01 44.252842) (xy 181.01 43.97487) (xy 181.04418 43.964502) + (xy 181.154494 43.905537) (xy 181.251185 43.826185) (xy 181.330537 43.729494) (xy 181.389502 43.61918) (xy 181.425812 43.499482) + (xy 181.438072 43.375) (xy 181.438072 42.375) (xy 181.425812 42.250518) (xy 181.389502 42.13082) (xy 181.330537 42.020506) + (xy 181.313708 42) (xy 181.330537 41.979494) (xy 181.389502 41.86918) (xy 181.425812 41.749482) (xy 181.438072 41.625) + (xy 181.435 41.41075) (xy 181.27625 41.252) (xy 180.127 41.252) (xy 180.127 41.272) (xy 180.06 41.272) + (xy 180.06 40.978) (xy 180.127 40.978) (xy 180.127 40.998) (xy 181.27625 40.998) (xy 181.435 40.83925) + (xy 181.436495 40.735) (xy 181.58224 40.735) (xy 181.74356 40.702911) (xy 181.895521 40.639967) (xy 182.032281 40.548587) + (xy 182.148587 40.432281) (xy 182.239967 40.295521) (xy 182.302911 40.14356) (xy 182.335 39.98224) (xy 182.335 39.81776) + (xy 182.302911 39.65644) (xy 182.239967 39.504479) (xy 182.148587 39.367719) (xy 182.032281 39.251413) (xy 181.895521 39.160033) + (xy 181.791922 39.117121) (xy 181.634801 38.96) (xy 188.535199 38.96) + ) + ) + (filled_polygon + (pts + (xy 101.570506 122.594463) (xy 101.473815 122.673815) (xy 101.394463 122.770506) (xy 101.335498 122.88082) (xy 101.299188 123.000518) + (xy 101.286928 123.125) (xy 101.286928 123.813271) (xy 100.883078 124.217121) (xy 100.779479 124.260033) (xy 100.642719 124.351413) + (xy 100.526413 124.467719) (xy 100.435033 124.604479) (xy 100.372089 124.75644) (xy 100.34 124.91776) (xy 100.34 125.08224) + (xy 100.372089 125.24356) (xy 100.435033 125.395521) (xy 100.526413 125.532281) (xy 100.642719 125.648587) (xy 100.779479 125.739967) + (xy 100.93144 125.802911) (xy 101.09276 125.835) (xy 101.25724 125.835) (xy 101.41856 125.802911) (xy 101.570521 125.739967) + (xy 101.707281 125.648587) (xy 101.823587 125.532281) (xy 101.914967 125.395521) (xy 101.957879 125.291922) (xy 102.064895 125.184907) + (xy 102.000033 125.281979) (xy 101.937089 125.43394) (xy 101.905 125.59526) (xy 101.905 125.75974) (xy 101.937089 125.92106) + (xy 102.000033 126.073021) (xy 102.091413 126.209781) (xy 102.207719 126.326087) (xy 102.339015 126.413816) (xy 102.784536 126.859338) + (xy 101.607306 126.859338) (xy 101.543653 126.770509) (xy 101.452359 126.685003) (xy 101.346137 126.61895) (xy 101.22907 126.574889) + (xy 101.105657 126.554513) (xy 100.98064 126.558606) (xy 100.858824 126.587009) (xy 100.744889 126.638632) (xy 100.659567 126.687893) + (xy 100.446477 126.474803) (xy 100.422674 126.445799) (xy 100.306949 126.350826) (xy 100.17492 126.280254) (xy 100.031659 126.236797) + (xy 99.920006 126.2258) (xy 99.919995 126.2258) (xy 99.882673 126.222124) (xy 99.845351 126.2258) (xy 98.856357 126.2258) + (xy 98.75276 126.182889) (xy 98.59144 126.1508) (xy 98.42696 126.1508) (xy 98.26564 126.182889) (xy 98.113679 126.245833) + (xy 97.976919 126.337213) (xy 97.860613 126.453519) (xy 97.769233 126.590279) (xy 97.706289 126.74224) (xy 97.6742 126.90356) + (xy 97.6742 127.06804) (xy 97.706289 127.22936) (xy 97.769233 127.381321) (xy 97.860613 127.518081) (xy 97.953124 127.610592) + (xy 97.894454 127.720353) (xy 97.850997 127.863614) (xy 97.84 127.975267) (xy 97.84 127.975278) (xy 97.836324 128.0126) + (xy 97.84 128.049922) (xy 97.84 128.05635) (xy 97.836324 128.093672) (xy 97.84 128.130994) (xy 97.84 128.131004) + (xy 97.850997 128.242657) (xy 97.879174 128.335546) (xy 97.894454 128.385918) (xy 97.965026 128.517948) (xy 97.998154 128.558314) + (xy 98.048775 128.619996) (xy 98.049741 128.649504) (xy 98.078144 128.771321) (xy 98.129768 128.885255) (xy 98.509144 129.542354) + (xy 98.294489 129.666285) (xy 98.262569 129.680748) (xy 98.234084 129.70116) (xy 98.234082 129.701161) (xy 98.148886 129.762211) + (xy 98.05328 129.864289) (xy 97.979426 129.983056) (xy 97.930161 130.11395) (xy 97.907379 130.25194) (xy 97.911955 130.391721) + (xy 97.943713 130.527926) (xy 98.001434 130.655317) (xy 98.021847 130.683803) (xy 98.363544 131.27564) (xy 97.981825 131.020583) + (xy 97.493186 130.818183) (xy 96.974449 130.715) (xy 96.445551 130.715) (xy 95.926814 130.818183) (xy 95.438175 131.020583) + (xy 94.998412 131.314424) (xy 94.740295 131.572541) (xy 94.740295 131.160165) (xy 94.702229 130.968796) (xy 94.893158 130.930818) + (xy 95.163411 130.818876) (xy 95.406632 130.656361) (xy 95.613475 130.449518) (xy 95.77599 130.206297) (xy 95.887932 129.936044) + (xy 95.945 129.649146) (xy 95.945 129.356626) (xy 95.887932 129.069728) (xy 95.77599 128.799475) (xy 95.733355 128.735668) + (xy 95.694089 128.538264) (xy 95.574609 128.249812) (xy 95.40115 127.990212) (xy 95.180379 127.769441) (xy 94.920779 127.595982) + (xy 94.632327 127.476502) (xy 94.326109 127.415591) (xy 94.108815 127.415591) (xy 97.736928 123.787478) (xy 97.736928 124.075) + (xy 97.749188 124.199482) (xy 97.785498 124.31918) (xy 97.844463 124.429494) (xy 97.923815 124.526185) (xy 98.020506 124.605537) + (xy 98.13082 124.664502) (xy 98.250518 124.700812) (xy 98.375 124.713072) (xy 99.675 124.713072) (xy 99.799482 124.700812) + (xy 99.91918 124.664502) (xy 100.029494 124.605537) (xy 100.126185 124.526185) (xy 100.205537 124.429494) (xy 100.264502 124.31918) + (xy 100.300812 124.199482) (xy 100.313072 124.075) (xy 100.313072 123.56173) (xy 100.491923 123.382878) (xy 100.595521 123.339967) + (xy 100.732281 123.248587) (xy 100.848587 123.132281) (xy 100.939967 122.995521) (xy 101.002911 122.84356) (xy 101.035 122.68224) + (xy 101.035 122.584799) (xy 101.588586 122.584799) + ) + ) + (filled_polygon + (pts + (xy 151.995911 121.752327) (xy 152.115391 122.040779) (xy 152.28885 122.300379) (xy 152.509621 122.52115) (xy 152.769221 122.694609) + (xy 152.935016 122.763283) (xy 152.897988 122.818699) (xy 152.737047 123.207245) (xy 152.655 123.619722) (xy 152.655 124.04028) + (xy 152.737047 124.452757) (xy 152.869252 124.771928) (xy 151.75 124.771928) (xy 151.625518 124.784188) (xy 151.50582 124.820498) + (xy 151.395506 124.879463) (xy 151.298815 124.958815) (xy 151.219463 125.055506) (xy 151.160498 125.16582) (xy 151.124188 125.285518) + (xy 151.111928 125.41) (xy 151.111928 127.41) (xy 151.124188 127.534482) (xy 151.160498 127.65418) (xy 151.219463 127.764494) + (xy 151.298815 127.861185) (xy 151.395506 127.940537) (xy 151.50582 127.999502) (xy 151.625518 128.035812) (xy 151.75 128.048072) + (xy 153.46327 128.048072) (xy 153.484188 128.06899) (xy 147.040831 128.06899) (xy 147.063795 128.041008) (xy 147.063799 128.041004) + (xy 147.134973 127.954277) (xy 147.134974 127.954276) (xy 147.154326 127.918072) (xy 147.65 127.918072) (xy 147.774482 127.905812) + (xy 147.89418 127.869502) (xy 148.004494 127.810537) (xy 148.101185 127.731185) (xy 148.180537 127.634494) (xy 148.239502 127.52418) + (xy 148.275812 127.404482) (xy 148.288072 127.28) (xy 148.288072 125.28) (xy 148.275812 125.155518) (xy 148.239502 125.03582) + (xy 148.180537 124.925506) (xy 148.101185 124.828815) (xy 148.004494 124.749463) (xy 147.89418 124.690498) (xy 147.774482 124.654188) + (xy 147.65 124.641928) (xy 145.856887 124.641928) (xy 145.984609 124.450779) (xy 146.104089 124.162327) (xy 146.165 123.856109) + (xy 146.165 123.543891) (xy 146.104089 123.237673) (xy 145.984609 122.949221) (xy 145.939361 122.881502) (xy 147.999843 122.881502) + (xy 148.10344 122.924413) (xy 148.26476 122.956502) (xy 148.42924 122.956502) (xy 148.59056 122.924413) (xy 148.742521 122.861469) + (xy 148.879281 122.770089) (xy 148.995587 122.653783) (xy 149.086967 122.517023) (xy 149.149911 122.365062) (xy 149.174231 122.2428) + (xy 151.024091 122.2428) (xy 151.061413 122.246476) (xy 151.098735 122.2428) (xy 151.098746 122.2428) (xy 151.210399 122.231803) + (xy 151.35366 122.188346) (xy 151.485689 122.117774) (xy 151.601414 122.022801) (xy 151.625217 121.993797) (xy 151.974471 121.644543) + ) + ) + (filled_polygon + (pts + (xy 104.3544 122.70704) (xy 104.386489 122.86836) (xy 104.449433 123.020321) (xy 104.540813 123.157081) (xy 104.657119 123.273387) + (xy 104.793879 123.364767) (xy 104.94584 123.427711) (xy 105.09781 123.45794) (xy 105.015 123.54075) (xy 105.011928 123.755) + (xy 105.024188 123.879482) (xy 105.060498 123.99918) (xy 105.119463 124.109494) (xy 105.136292 124.13) (xy 105.119463 124.150506) + (xy 105.060498 124.26082) (xy 105.024188 124.380518) (xy 105.011928 124.505) (xy 105.011928 125.505) (xy 105.017601 125.562598) + (xy 104.940199 125.64) (xy 103.714802 125.64) (xy 103.551396 125.476594) (xy 103.542911 125.43394) (xy 103.479967 125.281979) + (xy 103.388587 125.145219) (xy 103.272281 125.028913) (xy 103.135521 124.937533) (xy 102.98356 124.874589) (xy 102.82224 124.8425) + (xy 102.65776 124.8425) (xy 102.49644 124.874589) (xy 102.344479 124.937533) (xy 102.247407 125.002394) (xy 102.53673 124.713072) + (xy 103.225 124.713072) (xy 103.349482 124.700812) (xy 103.46918 124.664502) (xy 103.579494 124.605537) (xy 103.676185 124.526185) + (xy 103.755537 124.429494) (xy 103.814502 124.31918) (xy 103.850812 124.199482) (xy 103.863072 124.075) (xy 103.863072 123.125) + (xy 103.850812 123.000518) (xy 103.814502 122.88082) (xy 103.755537 122.770506) (xy 103.676185 122.673815) (xy 103.579494 122.594463) + (xy 103.561414 122.584799) (xy 104.3544 122.584799) + ) + ) + (filled_polygon + (pts + (xy 107.361728 121.0998) (xy 107.373988 121.224282) (xy 107.410298 121.34398) (xy 107.469263 121.454294) (xy 107.548615 121.550985) + (xy 107.645306 121.630337) (xy 107.75562 121.689302) (xy 107.875318 121.725612) (xy 107.9998 121.737872) (xy 109.2998 121.737872) + (xy 109.424282 121.725612) (xy 109.54398 121.689302) (xy 109.654294 121.630337) (xy 109.699999 121.592828) (xy 109.699998 122.222062) + (xy 109.695506 122.224463) (xy 109.598815 122.303815) (xy 109.519463 122.400506) (xy 109.460498 122.51082) (xy 109.424188 122.630518) + (xy 109.411928 122.755) (xy 109.411928 123.030002) (xy 109.108077 123.333853) (xy 109.004479 123.376765) (xy 108.867719 123.468145) + (xy 108.839569 123.496295) (xy 108.68224 123.465) (xy 108.51776 123.465) (xy 108.35644 123.497089) (xy 108.275051 123.530801) + (xy 108.12625 123.382) (xy 106.777 123.382) (xy 106.777 123.402) (xy 106.523 123.402) (xy 106.523 123.382) + (xy 106.503 123.382) (xy 106.503 123.128) (xy 106.523 123.128) (xy 106.523 122.27875) (xy 106.777 122.27875) + (xy 106.777 123.128) (xy 108.12625 123.128) (xy 108.285 122.96925) (xy 108.288072 122.755) (xy 108.275812 122.630518) + (xy 108.239502 122.51082) (xy 108.180537 122.400506) (xy 108.101185 122.303815) (xy 108.004494 122.224463) (xy 107.89418 122.165498) + (xy 107.774482 122.129188) (xy 107.65 122.116928) (xy 106.93575 122.12) (xy 106.777 122.27875) (xy 106.523 122.27875) + (xy 106.36425 122.12) (xy 105.956555 122.118246) (xy 107.361728 120.713074) + ) + ) + (filled_polygon + (pts + (xy 142.027 117.198) (xy 142.047 117.198) (xy 142.047 117.452) (xy 142.027 117.452) (xy 142.027 117.472) + (xy 141.9604 117.472) (xy 141.9604 117.178) (xy 142.027 117.178) + ) + ) + (filled_polygon + (pts + (xy 161.127 114.788) (xy 161.147 114.788) (xy 161.147 115.042) (xy 161.127 115.042) (xy 161.127 115.062) + (xy 161.0604 115.062) (xy 161.0604 114.768) (xy 161.127 114.768) + ) + ) + (filled_polygon + (pts + (xy 115.554951 99.743471) (xy 115.521184 99.771183) (xy 115.493471 99.804951) (xy 115.493468 99.804954) (xy 115.41059 99.905941) + (xy 115.328412 100.059687) (xy 115.277805 100.22651) (xy 115.260719 100.4) (xy 115.265001 100.443479) (xy 115.265 101.78153) + (xy 115.260719 101.825) (xy 115.265 101.868469) (xy 115.265 101.868476) (xy 115.271749 101.937) (xy 115.277805 101.99849) + (xy 115.287962 102.031973) (xy 115.328411 102.165312) (xy 115.410589 102.319058) (xy 115.521183 102.453817) (xy 115.554956 102.481534) + (xy 116.14347 103.070049) (xy 116.171183 103.103817) (xy 116.204951 103.13153) (xy 116.204953 103.131532) (xy 116.284834 103.197089) + (xy 116.305941 103.214411) (xy 116.459687 103.296589) (xy 116.62651 103.347195) (xy 116.756523 103.36) (xy 116.756531 103.36) + (xy 116.797837 103.364068) (xy 116.848815 103.426185) (xy 116.945506 103.505537) (xy 117.05582 103.564502) (xy 117.175518 103.600812) + (xy 117.3 103.613072) (xy 118.04 103.613072) (xy 118.04 103.815123) (xy 118.036565 103.85) (xy 118.050273 103.989184) + (xy 118.090872 104.12302) (xy 118.1568 104.246363) (xy 118.245525 104.354475) (xy 118.330578 104.424276) (xy 118.353637 104.4432) + (xy 118.47698 104.509128) (xy 118.610816 104.549727) (xy 118.75 104.563435) (xy 118.784877 104.56) (xy 119.615858 104.56) + (xy 119.228175 104.720583) (xy 118.788412 105.014424) (xy 118.414424 105.388412) (xy 118.120583 105.828175) (xy 117.918183 106.316814) + (xy 117.815 106.835551) (xy 117.815 107.364449) (xy 117.918183 107.883186) (xy 117.923749 107.896623) (xy 117.701302 107.747989) + (xy 117.392012 107.619877) (xy 117.427932 107.533158) (xy 117.485 107.24626) (xy 117.485 106.95374) (xy 117.427932 106.666842) + (xy 117.31599 106.396589) (xy 117.153475 106.153368) (xy 116.946632 105.946525) (xy 116.703411 105.78401) (xy 116.433158 105.672068) + (xy 116.14626 105.615) (xy 115.976697 105.615) (xy 115.882327 105.575911) (xy 115.576109 105.515) (xy 115.263891 105.515) + (xy 114.957673 105.575911) (xy 114.669221 105.695391) (xy 114.409621 105.86885) (xy 114.18885 106.089621) (xy 114.015391 106.349221) + (xy 113.895911 106.637673) (xy 113.835 106.943891) (xy 113.835 107.256109) (xy 113.895911 107.562327) (xy 114.015391 107.850779) + (xy 114.18885 108.110379) (xy 114.409621 108.33115) (xy 114.669221 108.504609) (xy 114.835016 108.573283) (xy 114.797988 108.628699) + (xy 114.637047 109.017245) (xy 114.555 109.429722) (xy 114.555 109.85028) (xy 114.637047 110.262757) (xy 114.769252 110.581928) + (xy 113.65 110.581928) (xy 113.56 110.590792) (xy 113.56 105.362323) (xy 113.563676 105.325) (xy 113.56 105.287677) + (xy 113.56 105.287667) (xy 113.549003 105.176014) (xy 113.505546 105.032753) (xy 113.434974 104.900724) (xy 113.340001 104.784999) + (xy 113.311002 104.761201) (xy 113.113072 104.56327) (xy 113.113072 103.875) (xy 113.100812 103.750518) (xy 113.064502 103.63082) + (xy 113.005537 103.520506) (xy 112.926185 103.423815) (xy 112.832137 103.346632) (xy 112.835 103.33224) (xy 112.835 103.16776) + (xy 112.802911 103.00644) (xy 112.739967 102.854479) (xy 112.670156 102.75) (xy 112.739967 102.645521) (xy 112.802911 102.49356) + (xy 112.835 102.33224) (xy 112.835 102.16776) (xy 112.832137 102.153368) (xy 112.926185 102.076185) (xy 113.005537 101.979494) + (xy 113.064502 101.86918) (xy 113.100812 101.749482) (xy 113.113072 101.625) (xy 113.113072 100.711729) (xy 114.385802 99.439) + (xy 115.859422 99.439) + ) + ) + (filled_polygon + (pts + (xy 202.288997 104.363799) (xy 202.289002 104.363803) (xy 202.84 104.914802) (xy 202.840001 108.318472) (xy 202.790379 108.26885) + (xy 202.530779 108.095391) (xy 202.242327 107.975911) (xy 201.936109 107.915) (xy 201.623891 107.915) (xy 201.317673 107.975911) + (xy 201.223303 108.015) (xy 201.05374 108.015) (xy 200.766842 108.072068) (xy 200.496589 108.18401) (xy 200.253368 108.346525) + (xy 200.046525 108.553368) (xy 199.88401 108.796589) (xy 199.772068 109.066842) (xy 199.715 109.35374) (xy 199.715 109.64626) + (xy 199.772068 109.933158) (xy 199.807988 110.019876) (xy 199.498698 110.147988) (xy 199.276252 110.296622) (xy 199.281817 110.283186) + (xy 199.385 109.764449) (xy 199.385 109.235551) (xy 199.281817 108.716814) (xy 199.079417 108.228175) (xy 198.798349 107.807527) + (xy 198.898585 107.707291) (xy 198.989965 107.570531) (xy 199.032877 107.466933) (xy 199.611003 106.888807) (xy 199.640001 106.865009) + (xy 199.734974 106.749284) (xy 199.805546 106.617255) (xy 199.849003 106.473994) (xy 199.86 106.362341) (xy 199.86 106.362332) + (xy 199.863676 106.325009) (xy 199.86 106.287686) (xy 199.86 106.013072) (xy 199.9 106.013072) (xy 200.024482 106.000812) + (xy 200.14418 105.964502) (xy 200.254494 105.905537) (xy 200.351185 105.826185) (xy 200.430537 105.729494) (xy 200.489502 105.61918) + (xy 200.497824 105.591746) (xy 200.534747 105.580546) (xy 200.666776 105.509974) (xy 200.782501 105.415001) (xy 200.806303 105.385998) + (xy 201.261003 104.931298) (xy 201.290001 104.907501) (xy 201.384974 104.791776) (xy 201.455546 104.659747) (xy 201.499003 104.516486) + (xy 201.51 104.404833) (xy 201.51 104.404824) (xy 201.513676 104.367501) (xy 201.51 104.330178) (xy 201.51 104.097157) + (xy 201.552911 103.99356) (xy 201.585 103.83224) (xy 201.585 103.66776) (xy 201.583024 103.657825) + ) + ) + (filled_polygon + (pts + (xy 218.277 102.998) (xy 218.297 102.998) (xy 218.297 103.252) (xy 218.277 103.252) (xy 218.277 103.272) + (xy 218.21 103.272) (xy 218.21 102.978) (xy 218.277 102.978) + ) + ) + (filled_polygon + (pts + (xy 199.227 102.998) (xy 199.247 102.998) (xy 199.247 103.252) (xy 199.227 103.252) (xy 199.227 103.272) + (xy 199.16 103.272) (xy 199.16 102.978) (xy 199.227 102.978) + ) + ) + (filled_polygon + (pts + (xy 200.512457 101.935124) (xy 200.512457 102.235135) (xy 200.508781 102.272457) (xy 200.512457 102.309779) (xy 200.512457 102.30979) + (xy 200.523454 102.421443) (xy 200.566911 102.564704) (xy 200.637483 102.696733) (xy 200.732456 102.812458) (xy 200.761458 102.836259) + (xy 200.842175 102.916976) (xy 200.83224 102.915) (xy 200.66776 102.915) (xy 200.50644 102.947089) (xy 200.383534 102.997998) + (xy 200.376252 102.997998) (xy 200.535 102.83925) (xy 200.538072 102.625) (xy 200.525812 102.500518) (xy 200.489502 102.38082) + (xy 200.430537 102.270506) (xy 200.351185 102.173815) (xy 200.254494 102.094463) (xy 200.14418 102.035498) (xy 200.024482 101.999188) + (xy 199.9 101.986928) (xy 199.38575 101.99) (xy 199.227002 102.148748) (xy 199.227002 101.99) (xy 199.16 101.99) + (xy 199.16 101.784877) (xy 199.163435 101.75) (xy 199.149727 101.610816) (xy 199.109128 101.47698) (xy 199.0432 101.353637) + (xy 198.954475 101.245525) (xy 198.846363 101.1568) (xy 198.72302 101.090872) (xy 198.589184 101.050273) (xy 198.484877 101.04) + (xy 198.45 101.036565) (xy 198.415123 101.04) (xy 195.06 101.04) (xy 195.06 100.464799) (xy 196.691925 98.832876) + (xy 196.795521 98.789965) (xy 196.932281 98.698585) (xy 197.048587 98.582279) (xy 197.139967 98.445519) (xy 197.202911 98.293558) + (xy 197.216976 98.22285) (xy 200.512458 98.22285) + ) + ) + (filled_polygon + (pts + (xy 123.027 100.598) (xy 123.047 100.598) (xy 123.047 100.852) (xy 123.027 100.852) (xy 123.027 100.872) + (xy 122.96 100.872) (xy 122.96 100.578) (xy 123.027 100.578) + ) + ) + (filled_polygon + (pts + (xy 129.315026 90.774276) (xy 129.356655 90.825) (xy 129.41 90.890001) (xy 129.438998 90.913799) (xy 132.636211 94.111013) + (xy 132.660009 94.140011) (xy 132.775734 94.234984) (xy 132.907763 94.305556) (xy 133.051024 94.349013) (xy 133.162677 94.36001) + (xy 133.162686 94.36001) (xy 133.200009 94.363686) (xy 133.237332 94.36001) (xy 134.365187 94.36001) (xy 132.988998 95.736201) + (xy 132.96 95.759999) (xy 132.936202 95.788997) (xy 132.936201 95.788998) (xy 132.865026 95.875724) (xy 132.794454 96.007754) + (xy 132.766245 96.10075) (xy 132.750998 96.151014) (xy 132.743581 96.226324) (xy 132.736324 96.3) (xy 132.737085 96.307727) + (xy 132.645273 96.086072) (xy 132.318601 95.597174) (xy 131.902826 95.181399) (xy 131.413928 94.854727) (xy 130.870692 94.629712) + (xy 130.293997 94.515) (xy 129.706003 94.515) (xy 129.129308 94.629712) (xy 128.586072 94.854727) (xy 128.097174 95.181399) + (xy 127.681399 95.597174) (xy 127.354727 96.086072) (xy 127.129712 96.629308) (xy 127.015 97.206003) (xy 127.015 97.793997) + (xy 127.07809 98.111171) (xy 126.996274 98.044026) (xy 126.864245 97.973454) (xy 126.720984 97.929997) (xy 126.609331 97.919) + (xy 126.60932 97.919) (xy 126.571998 97.915324) (xy 126.534676 97.919) (xy 114.108322 97.919) (xy 114.070999 97.915324) + (xy 114.033676 97.919) (xy 114.033667 97.919) (xy 113.922014 97.929997) (xy 113.778753 97.973454) (xy 113.646724 98.044026) + (xy 113.530999 98.138999) (xy 113.507201 98.167997) (xy 112.76 98.915198) (xy 112.76 98.512333) (xy 112.763676 98.47501) + (xy 112.76 98.437687) (xy 112.76 98.437678) (xy 112.749003 98.326025) (xy 112.705546 98.182764) (xy 112.634974 98.050735) + (xy 112.584536 97.989276) (xy 112.563799 97.964007) (xy 112.563795 97.964003) (xy 112.540001 97.93501) (xy 112.511008 97.911216) + (xy 112.132879 97.533089) (xy 112.089968 97.429491) (xy 111.998588 97.292731) (xy 111.882282 97.176425) (xy 111.745522 97.085045) + (xy 111.593561 97.022101) (xy 111.585 97.020398) (xy 111.585 91.585) (xy 112.090199 91.585) (xy 112.487165 91.981967) + (xy 112.401413 92.067719) (xy 112.310033 92.204479) (xy 112.247089 92.35644) (xy 112.215 92.51776) (xy 112.215 92.68224) + (xy 112.247089 92.84356) (xy 112.290001 92.947159) (xy 112.29 94.216677) (xy 112.286324 94.254) (xy 112.29 94.291322) + (xy 112.29 94.291332) (xy 112.300997 94.402985) (xy 112.334574 94.513676) (xy 112.344454 94.546246) (xy 112.415026 94.678276) + (xy 112.441719 94.710801) (xy 112.509999 94.794001) (xy 112.539003 94.817804) (xy 114.357202 96.636004) (xy 114.381 96.665002) + (xy 114.409998 96.6888) (xy 114.496724 96.759975) (xy 114.598289 96.814263) (xy 114.628754 96.830547) (xy 114.772015 96.874004) + (xy 114.883668 96.885001) (xy 114.883678 96.885001) (xy 114.921001 96.888677) (xy 114.958323 96.885001) (xy 125.960677 96.885001) + (xy 125.997999 96.888677) (xy 126.035321 96.885001) (xy 126.035332 96.885001) (xy 126.146985 96.874004) (xy 126.290246 96.830547) + (xy 126.422275 96.759975) (xy 126.538 96.665002) (xy 126.561803 96.635998) (xy 128.261003 94.936799) (xy 128.290001 94.913001) + (xy 128.384974 94.797276) (xy 128.455546 94.665247) (xy 128.499003 94.521986) (xy 128.51 94.410333) (xy 128.513677 94.373) + (xy 128.51 94.335667) (xy 128.51 92.318072) (xy 128.65 92.318072) (xy 128.774482 92.305812) (xy 128.89418 92.269502) + (xy 129.004494 92.210537) (xy 129.101185 92.131185) (xy 129.180537 92.034494) (xy 129.239502 91.92418) (xy 129.275812 91.804482) + (xy 129.288072 91.68) (xy 129.288072 90.723849) + ) + ) + (filled_polygon + (pts + (xy 142.027 98.198) (xy 142.047 98.198) (xy 142.047 98.452) (xy 142.027 98.452) (xy 142.027 98.472) + (xy 141.96 98.472) (xy 141.96 98.178) (xy 142.027 98.178) + ) + ) + (filled_polygon + (pts + (xy 180.127 98.198) (xy 180.147 98.198) (xy 180.147 98.452) (xy 180.127 98.452) (xy 180.127 98.472) + (xy 180.06 98.472) (xy 180.06 98.178) (xy 180.127 98.178) + ) + ) + (filled_polygon + (pts + (xy 161.127 95.688) (xy 161.147 95.688) (xy 161.147 95.942) (xy 161.127 95.942) (xy 161.127 95.962) + (xy 161.06 95.962) (xy 161.06 95.668) (xy 161.127 95.668) + ) + ) + (filled_polygon + (pts + (xy 149.435498 40.37082) (xy 149.399188 40.490518) (xy 149.386928 40.615) (xy 149.386928 41.915) (xy 149.399188 42.039482) + (xy 149.435498 42.15918) (xy 149.494463 42.269494) (xy 149.573815 42.366185) (xy 149.670506 42.445537) (xy 149.695689 42.458998) + (xy 149.697093 42.466056) (xy 149.760037 42.618017) (xy 149.851417 42.754777) (xy 149.967723 42.871083) (xy 150.104483 42.962463) + (xy 150.256444 43.025407) (xy 150.417764 43.057496) (xy 150.582244 43.057496) (xy 150.743564 43.025407) (xy 150.895525 42.962463) + (xy 151.032285 42.871083) (xy 151.148591 42.754777) (xy 151.239971 42.618017) (xy 151.239981 42.617993) (xy 151.239981 43.586616) + (xy 151.21918 43.575498) (xy 151.099482 43.539188) (xy 150.975 43.526928) (xy 150.025 43.526928) (xy 149.900518 43.539188) + (xy 149.78082 43.575498) (xy 149.670506 43.634463) (xy 149.573815 43.713815) (xy 149.494463 43.810506) (xy 149.435498 43.92082) + (xy 149.399188 44.040518) (xy 149.386928 44.165) (xy 149.386928 45.465) (xy 149.399188 45.589482) (xy 149.435498 45.70918) + (xy 149.494463 45.819494) (xy 149.573815 45.916185) (xy 149.670506 45.995537) (xy 149.78082 46.054502) (xy 149.900518 46.090812) + (xy 150.025 46.103072) (xy 150.642612 46.103072) (xy 150.713913 46.209781) (xy 150.830219 46.326087) (xy 150.966979 46.417467) + (xy 151.11894 46.480411) (xy 151.23998 46.504488) (xy 151.23998 47.932657) (xy 151.236304 47.96998) (xy 151.23998 48.007302) + (xy 151.23998 48.007312) (xy 151.250977 48.118965) (xy 151.285871 48.233997) (xy 151.294434 48.262226) (xy 151.365006 48.394256) + (xy 151.389419 48.424003) (xy 151.459979 48.509981) (xy 151.488982 48.533783) (xy 151.492706 48.537507) (xy 151.395506 48.589463) + (xy 151.298815 48.668815) (xy 151.219463 48.765506) (xy 151.160498 48.87582) (xy 151.124188 48.995518) (xy 151.120799 49.029931) + (xy 151.082281 48.991413) (xy 150.945521 48.900033) (xy 150.79356 48.837089) (xy 150.63224 48.805) (xy 150.46776 48.805) + (xy 150.30644 48.837089) (xy 150.154479 48.900033) (xy 150.017719 48.991413) (xy 149.901413 49.107719) (xy 149.810033 49.244479) + (xy 149.747089 49.39644) (xy 149.715 49.55776) (xy 149.715 49.72224) (xy 149.747089 49.88356) (xy 149.810033 50.035521) + (xy 149.901413 50.172281) (xy 150.017719 50.288587) (xy 150.154479 50.379967) (xy 150.30644 50.442911) (xy 150.46776 50.475) + (xy 150.63224 50.475) (xy 150.79356 50.442911) (xy 150.945521 50.379967) (xy 151.082281 50.288587) (xy 151.111928 50.25894) + (xy 151.111928 50.32827) (xy 149.958078 51.482121) (xy 149.854479 51.525033) (xy 149.717719 51.616413) (xy 149.601413 51.732719) + (xy 149.510033 51.869479) (xy 149.447089 52.02144) (xy 149.415 52.18276) (xy 149.415 52.34724) (xy 149.447089 52.50856) + (xy 149.510033 52.660521) (xy 149.601413 52.797281) (xy 149.717719 52.913587) (xy 149.854479 53.004967) (xy 150.00644 53.067911) + (xy 150.16776 53.1) (xy 150.33224 53.1) (xy 150.49356 53.067911) (xy 150.645521 53.004967) (xy 150.782281 52.913587) + (xy 150.898587 52.797281) (xy 150.989967 52.660521) (xy 151.032879 52.556922) (xy 151.831729 51.758072) (xy 154.05 51.758072) + (xy 154.174482 51.745812) (xy 154.29418 51.709502) (xy 154.404494 51.650537) (xy 154.501185 51.571185) (xy 154.515002 51.554348) + (xy 154.699017 51.738363) (xy 154.933014 51.894715) (xy 154.848815 51.963815) (xy 154.769463 52.060506) (xy 154.710498 52.17082) + (xy 154.674188 52.290518) (xy 154.661928 52.415) (xy 154.665 52.62925) (xy 154.82375 52.788) (xy 156.173 52.788) + (xy 156.173 52.768) (xy 156.427 52.768) (xy 156.427 52.788) (xy 156.447 52.788) (xy 156.447 53.042) + (xy 156.427 53.042) (xy 156.427 53.062) (xy 156.173 53.062) (xy 156.173 53.042) (xy 154.876128 53.042) + (xy 154.74356 52.987089) (xy 154.58224 52.955) (xy 154.41776 52.955) (xy 154.25644 52.987089) (xy 154.152843 53.03) + (xy 151.537333 53.03) (xy 151.5 53.026323) (xy 151.462667 53.03) (xy 151.351014 53.040997) (xy 151.207753 53.084454) + (xy 151.075724 53.155026) (xy 150.959999 53.249999) (xy 150.936201 53.278997) (xy 149.095906 55.119293) (xy 149.00644 55.137089) + (xy 148.854479 55.200033) (xy 148.717719 55.291413) (xy 148.601413 55.407719) (xy 148.510033 55.544479) (xy 148.447089 55.69644) + (xy 148.415 55.85776) (xy 148.415 56.02224) (xy 148.447089 56.18356) (xy 148.510033 56.335521) (xy 148.601413 56.472281) + (xy 148.717719 56.588587) (xy 148.732475 56.598447) (xy 148.825724 56.674974) (xy 148.957754 56.745546) (xy 149.101015 56.789002) + (xy 149.25 56.803676) (xy 149.398985 56.789002) (xy 149.542246 56.745546) (xy 149.674276 56.674974) (xy 149.761002 56.603799) + (xy 149.763997 56.600804) (xy 149.782281 56.588587) (xy 149.898587 56.472281) (xy 149.910804 56.453997) (xy 151.814802 54.55) + (xy 153.807418 54.55) (xy 153.865026 54.657776) (xy 153.96 54.773501) (xy 153.988998 54.797299) (xy 154.376196 55.184497) + (xy 154.399999 55.213501) (xy 154.467608 55.268986) (xy 154.515723 55.308474) (xy 154.629529 55.369305) (xy 154.647753 55.379046) + (xy 154.706789 55.396954) (xy 154.710498 55.40918) (xy 154.769463 55.519494) (xy 154.848815 55.616185) (xy 154.945506 55.695537) + (xy 155.05582 55.754502) (xy 155.175518 55.790812) (xy 155.3 55.803072) (xy 155.5317 55.803072) (xy 155.494454 55.872754) + (xy 155.469507 55.954997) (xy 155.450998 56.016014) (xy 155.444642 56.080546) (xy 155.436324 56.165) (xy 155.440001 56.202332) + (xy 155.440001 56.576928) (xy 155.4 56.576928) (xy 155.275518 56.589188) (xy 155.15582 56.625498) (xy 155.045506 56.684463) + (xy 154.948815 56.763815) (xy 154.869463 56.860506) (xy 154.810498 56.97082) (xy 154.774188 57.090518) (xy 154.761928 57.215) + (xy 154.761928 57.70327) (xy 154.458077 58.007121) (xy 154.354479 58.050033) (xy 154.217719 58.141413) (xy 154.101413 58.257719) + (xy 154.010033 58.394479) (xy 153.947089 58.54644) (xy 153.915 58.70776) (xy 153.915 58.87224) (xy 153.947089 59.03356) + (xy 154.010033 59.185521) (xy 154.087284 59.301135) (xy 153.443467 59.944953) (xy 153.360589 60.04594) (xy 153.278411 60.199686) + (xy 153.268188 60.233386) (xy 152.282879 59.248078) (xy 152.239967 59.144479) (xy 152.148587 59.007719) (xy 152.032281 58.891413) + (xy 151.895521 58.800033) (xy 151.797867 58.759583) (xy 151.790001 58.749999) (xy 151.674276 58.655026) (xy 151.542247 58.584454) + (xy 151.398986 58.540997) (xy 151.352874 58.536455) (xy 151.350812 58.515518) (xy 151.314502 58.39582) (xy 151.255537 58.285506) + (xy 151.176185 58.188815) (xy 151.079494 58.109463) (xy 150.96918 58.050498) (xy 150.849482 58.014188) (xy 150.725 58.001928) + (xy 149.775 58.001928) (xy 149.650518 58.014188) (xy 149.53082 58.050498) (xy 149.420506 58.109463) (xy 149.323815 58.188815) + (xy 149.244463 58.285506) (xy 149.185498 58.39582) (xy 149.149188 58.515518) (xy 149.136928 58.64) (xy 149.136928 59.94) + (xy 149.149188 60.064482) (xy 149.185498 60.18418) (xy 149.244463 60.294494) (xy 149.323815 60.391185) (xy 149.420506 60.470537) + (xy 149.53082 60.529502) (xy 149.650518 60.565812) (xy 149.775 60.578072) (xy 150.725 60.578072) (xy 150.849482 60.565812) + (xy 150.96918 60.529502) (xy 151.079494 60.470537) (xy 151.176185 60.391185) (xy 151.22135 60.336151) (xy 152.8642 61.979002) + (xy 152.887999 62.008001) (xy 153.003724 62.102974) (xy 153.135753 62.173546) (xy 153.279014 62.217003) (xy 153.390667 62.228) + (xy 153.390675 62.228) (xy 153.428 62.231676) (xy 153.465325 62.228) (xy 156.664836 62.228) (xy 156.514424 62.378412) + (xy 156.220583 62.818175) (xy 156.018183 63.306814) (xy 155.915 63.825551) (xy 155.915 64.354449) (xy 156.018183 64.873186) + (xy 156.023749 64.886623) (xy 155.801302 64.737989) (xy 155.492012 64.609877) (xy 155.527932 64.523158) (xy 155.585 64.23626) + (xy 155.585 63.94374) (xy 155.527932 63.656842) (xy 155.41599 63.386589) (xy 155.253475 63.143368) (xy 155.046632 62.936525) + (xy 154.803411 62.77401) (xy 154.533158 62.662068) (xy 154.24626 62.605) (xy 154.076697 62.605) (xy 153.982327 62.565911) + (xy 153.676109 62.505) (xy 153.363891 62.505) (xy 153.057673 62.565911) (xy 152.769221 62.685391) (xy 152.509621 62.85885) + (xy 152.37967 62.988802) (xy 152.282281 62.891413) (xy 152.145521 62.800033) (xy 151.99356 62.737089) (xy 151.83224 62.705) + (xy 151.66776 62.705) (xy 151.50644 62.737089) (xy 151.363072 62.796474) (xy 151.363072 62.19) (xy 151.350812 62.065518) + (xy 151.314502 61.94582) (xy 151.255537 61.835506) (xy 151.176185 61.738815) (xy 151.079494 61.659463) (xy 151.077778 61.658546) + (xy 151.085 61.62224) (xy 151.085 61.45776) (xy 151.052911 61.29644) (xy 150.989967 61.144479) (xy 150.898587 61.007719) + (xy 150.782281 60.891413) (xy 150.645521 60.800033) (xy 150.49356 60.737089) (xy 150.33224 60.705) (xy 150.16776 60.705) + (xy 150.00644 60.737089) (xy 149.854479 60.800033) (xy 149.717719 60.891413) (xy 149.601413 61.007719) (xy 149.510033 61.144479) + (xy 149.447089 61.29644) (xy 149.415 61.45776) (xy 149.415 61.62224) (xy 149.422222 61.658546) (xy 149.420506 61.659463) + (xy 149.323815 61.738815) (xy 149.244463 61.835506) (xy 149.185498 61.94582) (xy 149.149188 62.065518) (xy 149.136928 62.19) + (xy 149.136928 63.49) (xy 149.149188 63.614482) (xy 149.185498 63.73418) (xy 149.244463 63.844494) (xy 149.323815 63.941185) + (xy 149.420506 64.020537) (xy 149.53082 64.079502) (xy 149.650518 64.115812) (xy 149.775 64.128072) (xy 150.725 64.128072) + (xy 150.849482 64.115812) (xy 150.96918 64.079502) (xy 150.990001 64.068373) (xy 150.99 67.606544) (xy 150.98224 67.605) + (xy 150.81776 67.605) (xy 150.65644 67.637089) (xy 150.504479 67.700033) (xy 150.367719 67.791413) (xy 150.251413 67.907719) + (xy 150.160033 68.044479) (xy 150.097089 68.19644) (xy 150.065 68.35776) (xy 150.065 68.52224) (xy 150.097089 68.68356) + (xy 150.140001 68.787159) (xy 150.14 71.202679) (xy 150.136324 71.240002) (xy 150.14 71.277324) (xy 150.14 71.277334) + (xy 150.150997 71.388987) (xy 150.191046 71.521014) (xy 150.194454 71.532248) (xy 150.265026 71.664278) (xy 150.293859 71.699411) + (xy 150.359999 71.780003) (xy 150.389002 71.803805) (xy 151.061204 72.476009) (xy 151.084998 72.505002) (xy 151.113991 72.528796) + (xy 151.113995 72.5288) (xy 151.129161 72.541246) (xy 151.200723 72.599975) (xy 151.332752 72.670547) (xy 151.476013 72.714004) + (xy 151.587666 72.725001) (xy 151.587675 72.725001) (xy 151.624998 72.728677) (xy 151.662321 72.725001) (xy 164.587677 72.725001) + (xy 164.624999 72.728677) (xy 164.662321 72.725001) (xy 164.662332 72.725001) (xy 164.773985 72.714004) (xy 164.917246 72.670547) + (xy 165.049275 72.599975) (xy 165.165 72.505002) (xy 165.188803 72.475999) (xy 166.111003 71.553799) (xy 166.140001 71.530001) + (xy 166.234974 71.414276) (xy 166.305546 71.282247) (xy 166.349003 71.138986) (xy 166.36 71.027333) (xy 166.36 71.027325) + (xy 166.363676 70.99) (xy 166.36 70.952675) (xy 166.36 68.308072) (xy 166.365001 68.308072) (xy 166.365 77.996531) + (xy 166.360719 78.04) (xy 166.365 78.083469) (xy 166.365 78.083476) (xy 166.371068 78.145082) (xy 166.377805 78.21349) + (xy 166.392159 78.260808) (xy 166.428411 78.380312) (xy 166.44 78.401994) (xy 166.44 84.131928) (xy 164.956887 84.131928) + (xy 165.084609 83.940779) (xy 165.204089 83.652327) (xy 165.265 83.346109) (xy 165.265 83.033891) (xy 165.204089 82.727673) + (xy 165.084609 82.439221) (xy 165.041712 82.375021) (xy 165.08224 82.375021) (xy 165.24356 82.342932) (xy 165.395521 82.279988) + (xy 165.532281 82.188608) (xy 165.648587 82.072302) (xy 165.739967 81.935542) (xy 165.802911 81.783581) (xy 165.835 81.622261) + (xy 165.835 81.457781) (xy 165.802911 81.296461) (xy 165.76 81.192864) (xy 165.76 78.887157) (xy 165.802911 78.78356) + (xy 165.835 78.62224) (xy 165.835 78.45776) (xy 165.802911 78.29644) (xy 165.739967 78.144479) (xy 165.648587 78.007719) + (xy 165.532281 77.891413) (xy 165.395521 77.800033) (xy 165.24356 77.737089) (xy 165.08224 77.705) (xy 164.91776 77.705) + (xy 164.75644 77.737089) (xy 164.604479 77.800033) (xy 164.467719 77.891413) (xy 164.351413 78.007719) (xy 164.260033 78.144479) + (xy 164.197089 78.29644) (xy 164.165 78.45776) (xy 164.165 78.62224) (xy 164.197089 78.78356) (xy 164.24 78.887157) + (xy 164.240001 81.192862) (xy 164.197089 81.296461) (xy 164.165 81.457781) (xy 164.165 81.622261) (xy 164.176498 81.680065) + (xy 164.142327 81.665911) (xy 163.836109 81.605) (xy 163.523891 81.605) (xy 163.217673 81.665911) (xy 163.123303 81.705) + (xy 162.95374 81.705) (xy 162.666842 81.762068) (xy 162.396589 81.87401) (xy 162.153368 82.036525) (xy 161.946525 82.243368) + (xy 161.78401 82.486589) (xy 161.76 82.544555) (xy 161.76 79.703072) (xy 161.8 79.703072) (xy 161.924482 79.690812) + (xy 162.04418 79.654502) (xy 162.154494 79.595537) (xy 162.251185 79.516185) (xy 162.330537 79.419494) (xy 162.389502 79.30918) + (xy 162.425812 79.189482) (xy 162.438072 79.065) (xy 162.438072 78.52703) (xy 162.680497 78.284605) (xy 162.709494 78.260808) + (xy 162.804467 78.145083) (xy 162.875039 78.013054) (xy 162.918496 77.869793) (xy 162.922094 77.833265) (xy 162.972404 77.711805) + (xy 163.004493 77.550485) (xy 163.004493 77.386005) (xy 162.972404 77.224685) (xy 162.90946 77.072724) (xy 162.81808 76.935964) + (xy 162.701774 76.819658) (xy 162.565014 76.728278) (xy 162.413053 76.665334) (xy 162.317853 76.646397) (xy 162.435 76.52925) + (xy 162.438072 76.315) (xy 162.425812 76.190518) (xy 162.389502 76.07082) (xy 162.330537 75.960506) (xy 162.251185 75.863815) + (xy 162.154494 75.784463) (xy 162.04418 75.725498) (xy 161.924482 75.689188) (xy 161.8 75.676928) (xy 161.28575 75.68) + (xy 161.127002 75.838748) (xy 161.127002 75.68) (xy 161.06 75.68) (xy 161.06 75.491077) (xy 161.063435 75.4562) + (xy 161.049727 75.317016) (xy 161.009128 75.18318) (xy 160.9432 75.059837) (xy 160.854475 74.951725) (xy 160.746363 74.863) + (xy 160.62302 74.797072) (xy 160.489184 74.756473) (xy 160.384877 74.7462) (xy 160.35 74.742765) (xy 160.315123 74.7462) + (xy 156.884877 74.7462) (xy 156.85 74.742765) (xy 156.815123 74.7462) (xy 156.710816 74.756473) (xy 156.57698 74.797072) + (xy 156.453637 74.863) (xy 156.345525 74.951725) (xy 156.2568 75.059837) (xy 156.190872 75.18318) (xy 156.150273 75.317016) + (xy 156.136565 75.4562) (xy 156.140001 75.491087) (xy 156.140001 75.676928) (xy 155.4 75.676928) (xy 155.275518 75.689188) + (xy 155.15582 75.725498) (xy 155.045506 75.784463) (xy 154.948815 75.863815) (xy 154.869463 75.960506) (xy 154.818954 76.055) + (xy 154.449145 76.055) (xy 154.411812 76.051323) (xy 154.374479 76.055) (xy 154.262826 76.065997) (xy 154.119565 76.109454) + (xy 153.987536 76.180026) (xy 153.871811 76.274999) (xy 153.848013 76.303998) (xy 153.089002 77.063009) (xy 153.059999 77.086811) + (xy 153.015189 77.141413) (xy 152.965026 77.202536) (xy 152.912615 77.30059) (xy 152.894454 77.334566) (xy 152.850997 77.477827) + (xy 152.84 77.58948) (xy 152.84 77.58949) (xy 152.836324 77.626812) (xy 152.84 77.664134) (xy 152.84 77.692843) + (xy 152.797089 77.79644) (xy 152.765 77.95776) (xy 152.765 78.12224) (xy 152.797089 78.28356) (xy 152.860033 78.435521) + (xy 152.951413 78.572281) (xy 153.067719 78.688587) (xy 153.204479 78.779967) (xy 153.35644 78.842911) (xy 153.415003 78.85456) + (xy 153.415003 79.596523) (xy 153.410721 79.640002) (xy 153.427807 79.813492) (xy 153.478414 79.980315) (xy 153.560592 80.134061) + (xy 153.64347 80.235048) (xy 153.643473 80.235051) (xy 153.671186 80.268819) (xy 153.704953 80.296531) (xy 154.64347 81.235049) + (xy 154.671183 81.268817) (xy 154.704951 81.29653) (xy 154.704953 81.296532) (xy 154.784976 81.362205) (xy 154.805941 81.379411) + (xy 154.959687 81.461589) (xy 155.12651 81.512195) (xy 155.256523 81.525) (xy 155.256531 81.525) (xy 155.3 81.529281) + (xy 155.343469 81.525) (xy 156.483295 81.525) (xy 156.220583 81.918175) (xy 156.018183 82.406814) (xy 155.915 82.925551) + (xy 155.915 83.454449) (xy 156.018183 83.973186) (xy 156.023749 83.986623) (xy 155.801302 83.837989) (xy 155.492012 83.709877) + (xy 155.527932 83.623158) (xy 155.585 83.33626) (xy 155.585 83.04374) (xy 155.527932 82.756842) (xy 155.41599 82.486589) + (xy 155.253475 82.243368) (xy 155.046632 82.036525) (xy 154.803411 81.87401) (xy 154.533158 81.762068) (xy 154.24626 81.705) + (xy 154.076697 81.705) (xy 153.982327 81.665911) (xy 153.676109 81.605) (xy 153.363891 81.605) (xy 153.057673 81.665911) + (xy 152.769221 81.785391) (xy 152.509621 81.95885) (xy 152.28885 82.179621) (xy 152.115391 82.439221) (xy 151.995911 82.727673) + (xy 151.935 83.033891) (xy 151.935 83.346109) (xy 151.995911 83.652327) (xy 152.115391 83.940779) (xy 152.28885 84.200379) + (xy 152.509621 84.42115) (xy 152.769221 84.594609) (xy 152.935016 84.663283) (xy 152.897988 84.718699) (xy 152.737047 85.107245) + (xy 152.655 85.519722) (xy 152.655 85.94028) (xy 152.737047 86.352757) (xy 152.869252 86.671928) (xy 151.75 86.671928) + (xy 151.625518 86.684188) (xy 151.50582 86.720498) (xy 151.395506 86.779463) (xy 151.298815 86.858815) (xy 151.240386 86.930011) + (xy 151.195521 86.900033) (xy 151.091923 86.857122) (xy 150.51 86.275199) (xy 150.51 84.557683) (xy 150.579494 84.520537) + (xy 150.676185 84.441185) (xy 150.755537 84.344494) (xy 150.814502 84.23418) (xy 150.850812 84.114482) (xy 150.863072 83.99) + (xy 150.863072 82.69) (xy 150.850812 82.565518) (xy 150.814502 82.44582) (xy 150.755537 82.335506) (xy 150.676185 82.238815) + (xy 150.579494 82.159463) (xy 150.46918 82.100498) (xy 150.349482 82.064188) (xy 150.225 82.051928) (xy 149.275 82.051928) + (xy 149.150518 82.064188) (xy 149.03082 82.100498) (xy 148.920506 82.159463) (xy 148.823815 82.238815) (xy 148.744463 82.335506) + (xy 148.685498 82.44582) (xy 148.649188 82.565518) (xy 148.636928 82.69) (xy 148.636928 83.99) (xy 148.649188 84.114482) + (xy 148.685498 84.23418) (xy 148.744463 84.344494) (xy 148.823815 84.441185) (xy 148.920506 84.520537) (xy 148.99 84.557683) + (xy 148.990001 86.527333) (xy 148.991249 86.54) (xy 148.986324 86.59) (xy 149.000998 86.738985) (xy 149.044454 86.882246) + (xy 149.115026 87.014276) (xy 149.186201 87.101002) (xy 150.017122 87.931923) (xy 150.040001 87.987159) (xy 150.04 88.977177) + (xy 150.036324 89.0145) (xy 150.04 89.051822) (xy 150.04 89.051832) (xy 150.050997 89.163485) (xy 150.084578 89.274188) + (xy 150.094454 89.306746) (xy 150.165026 89.438776) (xy 150.193507 89.47348) (xy 150.259999 89.554501) (xy 150.289003 89.578304) + (xy 152.330498 91.6198) (xy 149.961123 91.6198) (xy 149.92379 91.616123) (xy 149.886457 91.6198) (xy 149.774804 91.630797) + (xy 149.631543 91.674254) (xy 149.499514 91.744826) (xy 149.383789 91.839799) (xy 149.359991 91.868797) (xy 148.388779 92.84001) + (xy 146.90329 92.84001) (xy 146.955546 92.742247) (xy 146.999003 92.598986) (xy 147.01 92.487333) (xy 147.01 92.487325) + (xy 147.013676 92.45) (xy 147.01 92.412675) (xy 147.01 89.818072) (xy 147.65 89.818072) (xy 147.774482 89.805812) + (xy 147.89418 89.769502) (xy 148.004494 89.710537) (xy 148.101185 89.631185) (xy 148.180537 89.534494) (xy 148.239502 89.42418) + (xy 148.275812 89.304482) (xy 148.288072 89.18) (xy 148.288072 87.18) (xy 148.275812 87.055518) (xy 148.239502 86.93582) + (xy 148.180537 86.825506) (xy 148.101185 86.728815) (xy 148.004494 86.649463) (xy 147.89418 86.590498) (xy 147.774482 86.554188) + (xy 147.65 86.541928) (xy 145.856887 86.541928) (xy 145.984609 86.350779) (xy 146.104089 86.062327) (xy 146.165 85.756109) + (xy 146.165 85.443891) (xy 146.104089 85.137673) (xy 145.984609 84.849221) (xy 145.81115 84.589621) (xy 145.590379 84.36885) + (xy 145.330779 84.195391) (xy 145.042327 84.075911) (xy 144.736109 84.015) (xy 144.423891 84.015) (xy 144.117673 84.075911) + (xy 144.023303 84.115) (xy 143.85374 84.115) (xy 143.566842 84.172068) (xy 143.296589 84.28401) (xy 143.053368 84.446525) + (xy 142.846525 84.653368) (xy 142.68401 84.896589) (xy 142.572068 85.166842) (xy 142.515 85.45374) (xy 142.515 85.74626) + (xy 142.572068 86.033158) (xy 142.607988 86.119876) (xy 142.298698 86.247988) (xy 142.076252 86.396622) (xy 142.081817 86.383186) + (xy 142.185 85.864449) (xy 142.185 85.335551) (xy 142.081817 84.816814) (xy 141.879417 84.328175) (xy 141.585576 83.888412) + (xy 141.257164 83.56) (xy 146.71269 83.56) (xy 146.750012 83.563676) (xy 146.787334 83.56) (xy 146.787345 83.56) + (xy 146.898998 83.549003) (xy 147.042259 83.505546) (xy 147.174288 83.434974) (xy 147.290013 83.340001) (xy 147.313815 83.310998) + (xy 147.791935 82.832878) (xy 147.895533 82.789967) (xy 148.032293 82.698587) (xy 148.148599 82.582281) (xy 148.239979 82.445521) + (xy 148.302923 82.29356) (xy 148.335012 82.13224) (xy 148.335012 81.96776) (xy 148.302923 81.80644) (xy 148.239979 81.654479) + (xy 148.148599 81.517719) (xy 148.032293 81.401413) (xy 147.895533 81.310033) (xy 147.743572 81.247089) (xy 147.582252 81.215) + (xy 147.417772 81.215) (xy 147.256452 81.247089) (xy 147.104491 81.310033) (xy 146.967731 81.401413) (xy 146.851425 81.517719) + (xy 146.760045 81.654479) (xy 146.717134 81.758077) (xy 146.435211 82.04) (xy 142.990019 82.04) (xy 143.054494 82.005537) + (xy 143.151185 81.926185) (xy 143.230537 81.829494) (xy 143.289502 81.71918) (xy 143.325812 81.599482) (xy 143.338072 81.475) + (xy 143.338072 81.286729) (xy 143.941923 80.682878) (xy 144.045521 80.639967) (xy 144.182281 80.548587) (xy 144.298587 80.432281) + (xy 144.389967 80.295521) (xy 144.452911 80.14356) (xy 144.485 79.98224) (xy 144.485 79.81776) (xy 144.452911 79.65644) + (xy 144.389967 79.504479) (xy 144.298587 79.367719) (xy 144.182281 79.251413) (xy 144.045521 79.160033) (xy 143.997157 79.14) + (xy 148.636928 79.14) (xy 148.636928 80.44) (xy 148.649188 80.564482) (xy 148.685498 80.68418) (xy 148.744463 80.794494) + (xy 148.823815 80.891185) (xy 148.915 80.966018) (xy 148.915 81.02224) (xy 148.947089 81.18356) (xy 149.010033 81.335521) + (xy 149.101413 81.472281) (xy 149.217719 81.588587) (xy 149.354479 81.679967) (xy 149.50644 81.742911) (xy 149.66776 81.775) + (xy 149.83224 81.775) (xy 149.99356 81.742911) (xy 150.145521 81.679967) (xy 150.282281 81.588587) (xy 150.398587 81.472281) + (xy 150.489967 81.335521) (xy 150.552911 81.18356) (xy 150.585 81.02224) (xy 150.585 80.966018) (xy 150.676185 80.891185) + (xy 150.755537 80.794494) (xy 150.814502 80.68418) (xy 150.850812 80.564482) (xy 150.863072 80.44) (xy 150.863072 79.14) + (xy 150.850812 79.015518) (xy 150.814502 78.89582) (xy 150.755537 78.785506) (xy 150.676185 78.688815) (xy 150.579494 78.609463) + (xy 150.46918 78.550498) (xy 150.349482 78.514188) (xy 150.225 78.501928) (xy 149.275 78.501928) (xy 149.150518 78.514188) + (xy 149.03082 78.550498) (xy 148.920506 78.609463) (xy 148.823815 78.688815) (xy 148.744463 78.785506) (xy 148.685498 78.89582) + (xy 148.649188 79.015518) (xy 148.636928 79.14) (xy 143.997157 79.14) (xy 143.89356 79.097089) (xy 143.73224 79.065) + (xy 143.56776 79.065) (xy 143.40644 79.097089) (xy 143.335 79.12668) (xy 143.335 79.097998) (xy 143.176252 79.097998) + (xy 143.335 78.93925) (xy 143.338072 78.725) (xy 143.325812 78.600518) (xy 143.289502 78.48082) (xy 143.230537 78.370506) + (xy 143.151185 78.273815) (xy 143.054494 78.194463) (xy 142.94418 78.135498) (xy 142.824482 78.099188) (xy 142.7 78.086928) + (xy 142.18575 78.09) (xy 142.027002 78.248748) (xy 142.027002 78.09) (xy 141.96 78.09) (xy 141.96 77.984877) + (xy 141.963435 77.95) (xy 141.949727 77.810816) (xy 141.909128 77.67698) (xy 141.8432 77.553637) (xy 141.754475 77.445525) + (xy 141.646363 77.3568) (xy 141.52302 77.290872) (xy 141.389184 77.250273) (xy 141.284877 77.24) (xy 141.25 77.236565) + (xy 141.215123 77.24) (xy 137.784877 77.24) (xy 137.75 77.236565) (xy 137.715123 77.24) (xy 137.610816 77.250273) + (xy 137.47698 77.290872) (xy 137.353637 77.3568) (xy 137.245525 77.445525) (xy 137.1568 77.553637) (xy 137.090872 77.67698) + (xy 137.050273 77.810816) (xy 137.036565 77.95) (xy 137.040001 77.984887) (xy 137.040001 78.086928) (xy 136.3 78.086928) + (xy 136.175518 78.099188) (xy 136.05582 78.135498) (xy 135.945506 78.194463) (xy 135.848815 78.273815) (xy 135.769463 78.370506) + (xy 135.710498 78.48082) (xy 135.674188 78.600518) (xy 135.663209 78.711989) (xy 135.26 79.115199) (xy 135.26 79.081523) + (xy 135.247195 78.95151) (xy 135.196589 78.784687) (xy 135.114411 78.630941) (xy 135.003817 78.496183) (xy 134.869059 78.385589) + (xy 134.715313 78.303411) (xy 134.54849 78.252805) (xy 134.375 78.235718) (xy 134.201511 78.252805) (xy 134.034688 78.303411) + (xy 133.880942 78.385589) (xy 133.746184 78.496183) (xy 133.63559 78.630941) (xy 133.553412 78.784687) (xy 133.502806 78.95151) + (xy 133.490001 79.081523) (xy 133.49 80.28153) (xy 133.485719 80.325) (xy 133.49 80.368469) (xy 133.49 80.368476) + (xy 133.49737 80.443303) (xy 133.502805 80.49849) (xy 133.511305 80.52651) (xy 133.553411 80.665312) (xy 133.635589 80.819058) + (xy 133.746183 80.953817) (xy 133.779956 80.981534) (xy 134.268466 81.470044) (xy 134.296183 81.503817) (xy 134.430941 81.614411) + (xy 134.584687 81.696589) (xy 134.75151 81.747195) (xy 134.881523 81.76) (xy 134.881533 81.76) (xy 134.924999 81.764281) + (xy 134.968465 81.76) (xy 135.732317 81.76) (xy 135.769463 81.829494) (xy 135.848815 81.926185) (xy 135.945506 82.005537) + (xy 136.009981 82.04) (xy 132.464802 82.04) (xy 132.363072 81.93827) (xy 132.363072 81.25) (xy 132.350812 81.125518) + (xy 132.314502 81.00582) (xy 132.255537 80.895506) (xy 132.176185 80.798815) (xy 132.079494 80.719463) (xy 131.96918 80.660498) + (xy 131.849482 80.624188) (xy 131.725 80.611928) (xy 130.775 80.611928) (xy 130.650518 80.624188) (xy 130.53082 80.660498) + (xy 130.420506 80.719463) (xy 130.323815 80.798815) (xy 130.244463 80.895506) (xy 130.185498 81.00582) (xy 130.162691 81.081003) + (xy 130.08224 81.065) (xy 129.91776 81.065) (xy 129.75644 81.097089) (xy 129.652843 81.14) (xy 129.57487 81.14) + (xy 129.564502 81.10582) (xy 129.505537 80.995506) (xy 129.426185 80.898815) (xy 129.329494 80.819463) (xy 129.21918 80.760498) + (xy 129.099482 80.724188) (xy 128.975 80.711928) (xy 128.025 80.711928) (xy 127.900518 80.724188) (xy 127.78082 80.760498) + (xy 127.670506 80.819463) (xy 127.601169 80.876367) (xy 124.609802 77.885001) (xy 125.787677 77.885001) (xy 125.824999 77.888677) + (xy 125.862321 77.885001) (xy 125.862332 77.885001) (xy 125.973985 77.874004) (xy 126.117246 77.830547) (xy 126.249275 77.759975) + (xy 126.365 77.665002) (xy 126.388803 77.635998) (xy 128.011003 76.013799) (xy 128.040001 75.990001) (xy 128.071669 75.951413) + (xy 128.134974 75.874277) (xy 128.205546 75.742247) (xy 128.208437 75.732715) (xy 128.249003 75.598986) (xy 128.26 75.487333) + (xy 128.26 75.487324) (xy 128.263676 75.450001) (xy 128.26 75.412678) (xy 128.26 73.318072) (xy 128.65 73.318072) + (xy 128.774482 73.305812) (xy 128.89418 73.269502) (xy 129.004494 73.210537) (xy 129.101185 73.131185) (xy 129.180537 73.034494) + (xy 129.239502 72.92418) (xy 129.275812 72.804482) (xy 129.288072 72.68) (xy 129.288072 70.68) (xy 129.275812 70.555518) + (xy 129.239502 70.43582) (xy 129.180537 70.325506) (xy 129.101185 70.228815) (xy 129.004494 70.149463) (xy 128.89418 70.090498) + (xy 128.774482 70.054188) (xy 128.65 70.041928) (xy 128.26 70.041928) (xy 128.26 67.337322) (xy 128.263676 67.299999) + (xy 128.26 67.262676) (xy 128.26 67.262667) (xy 128.249003 67.151014) (xy 128.205546 67.007753) (xy 128.134974 66.875724) + (xy 128.121811 66.859685) (xy 128.063799 66.788996) (xy 128.063795 66.788992) (xy 128.040001 66.759999) (xy 128.011009 66.736206) + (xy 127.813813 66.539011) (xy 127.864502 66.44418) (xy 127.900812 66.324482) (xy 127.913072 66.2) (xy 127.913072 64.925) + (xy 128.686928 64.925) (xy 128.686928 66.225) (xy 128.699188 66.349482) (xy 128.735498 66.46918) (xy 128.794463 66.579494) + (xy 128.873815 66.676185) (xy 128.970506 66.755537) (xy 129.08082 66.814502) (xy 129.200518 66.850812) (xy 129.325 66.863072) + (xy 130.275 66.863072) (xy 130.399482 66.850812) (xy 130.51918 66.814502) (xy 130.629494 66.755537) (xy 130.726185 66.676185) + (xy 130.805537 66.579494) (xy 130.864502 66.46918) (xy 130.877311 66.426954) (xy 130.91776 66.435) (xy 131.08224 66.435) + (xy 131.24356 66.402911) (xy 131.395521 66.339967) (xy 131.532281 66.248587) (xy 131.648587 66.132281) (xy 131.739967 65.995521) + (xy 131.802911 65.84356) (xy 131.835 65.68224) (xy 131.835 65.51776) (xy 131.802911 65.35644) (xy 131.739967 65.204479) + (xy 131.648587 65.067719) (xy 131.532281 64.951413) (xy 131.395521 64.860033) (xy 131.24356 64.797089) (xy 131.08224 64.765) + (xy 130.91776 64.765) (xy 130.891615 64.770201) (xy 130.864502 64.68082) (xy 130.805537 64.570506) (xy 130.726185 64.473815) + (xy 130.629494 64.394463) (xy 130.51918 64.335498) (xy 130.399482 64.299188) (xy 130.275 64.286928) (xy 129.325 64.286928) + (xy 129.200518 64.299188) (xy 129.08082 64.335498) (xy 128.970506 64.394463) (xy 128.873815 64.473815) (xy 128.794463 64.570506) + (xy 128.735498 64.68082) (xy 128.699188 64.800518) (xy 128.686928 64.925) (xy 127.913072 64.925) (xy 127.913072 64.9) + (xy 127.900812 64.775518) (xy 127.864502 64.65582) (xy 127.805537 64.545506) (xy 127.726185 64.448815) (xy 127.629494 64.369463) + (xy 127.51918 64.310498) (xy 127.43104 64.283761) (xy 128.531923 63.182878) (xy 128.587155 63.16) (xy 128.915019 63.16) + (xy 128.970506 63.205537) (xy 129.08082 63.264502) (xy 129.200518 63.300812) (xy 129.325 63.313072) (xy 130.275 63.313072) + (xy 130.399482 63.300812) (xy 130.51918 63.264502) (xy 130.629494 63.205537) (xy 130.726185 63.126185) (xy 130.782619 63.05742) + (xy 131.986205 64.261008) (xy 132.009999 64.290001) (xy 132.038992 64.313795) (xy 132.038996 64.313799) (xy 132.101417 64.365026) + (xy 132.125724 64.384974) (xy 132.257753 64.455546) (xy 132.401014 64.499003) (xy 132.512667 64.51) (xy 132.512676 64.51) + (xy 132.549999 64.513676) (xy 132.587322 64.51) (xy 133.107199 64.51) (xy 133.158196 64.560997) (xy 133.181999 64.590001) + (xy 133.297724 64.684974) (xy 133.429753 64.755546) (xy 133.573014 64.799003) (xy 133.684667 64.81) (xy 133.684676 64.81) + (xy 133.721999 64.813676) (xy 133.759322 64.81) (xy 137.492836 64.81) (xy 137.414424 64.888412) (xy 137.120583 65.328175) + (xy 136.918183 65.816814) (xy 136.815 66.335551) (xy 136.815 66.864449) (xy 136.918183 67.383186) (xy 136.923749 67.396623) + (xy 136.701302 67.247989) (xy 136.392012 67.119877) (xy 136.427932 67.033158) (xy 136.485 66.74626) (xy 136.485 66.45374) + (xy 136.427932 66.166842) (xy 136.31599 65.896589) (xy 136.153475 65.653368) (xy 135.946632 65.446525) (xy 135.703411 65.28401) + (xy 135.433158 65.172068) (xy 135.14626 65.115) (xy 134.976697 65.115) (xy 134.882327 65.075911) (xy 134.576109 65.015) + (xy 134.263891 65.015) (xy 133.957673 65.075911) (xy 133.669221 65.195391) (xy 133.409621 65.36885) (xy 133.18885 65.589621) + (xy 133.015391 65.849221) (xy 132.895911 66.137673) (xy 132.835 66.443891) (xy 132.835 66.756109) (xy 132.895911 67.062327) + (xy 133.015391 67.350779) (xy 133.18885 67.610379) (xy 133.409621 67.83115) (xy 133.669221 68.004609) (xy 133.835016 68.073283) + (xy 133.797988 68.128699) (xy 133.637047 68.517245) (xy 133.555 68.929722) (xy 133.555 69.35028) (xy 133.637047 69.762757) + (xy 133.769252 70.081928) (xy 132.65 70.081928) (xy 132.525518 70.094188) (xy 132.40582 70.130498) (xy 132.295506 70.189463) + (xy 132.270401 70.210066) (xy 132.195521 70.160033) (xy 132.04356 70.097089) (xy 131.88224 70.065) (xy 131.71776 70.065) + (xy 131.55644 70.097089) (xy 131.404479 70.160033) (xy 131.267719 70.251413) (xy 131.151413 70.367719) (xy 131.060033 70.504479) + (xy 130.997089 70.65644) (xy 130.965 70.81776) (xy 130.965 70.98224) (xy 130.997089 71.14356) (xy 131.040001 71.247159) + (xy 131.04 73.662679) (xy 131.036324 73.700002) (xy 131.04 73.737324) (xy 131.04 73.737334) (xy 131.050997 73.848987) + (xy 131.084591 73.959733) (xy 131.094454 73.992248) (xy 131.165026 74.124278) (xy 131.195167 74.161004) (xy 131.259999 74.240003) + (xy 131.289002 74.263805) (xy 131.961204 74.936009) (xy 131.984998 74.965002) (xy 132.013991 74.988796) (xy 132.013995 74.9888) + (xy 132.058989 75.025725) (xy 132.100723 75.059975) (xy 132.232752 75.130547) (xy 132.376013 75.174004) (xy 132.487666 75.185001) + (xy 132.487675 75.185001) (xy 132.524998 75.188677) (xy 132.562321 75.185001) (xy 145.487677 75.185001) (xy 145.524999 75.188677) + (xy 145.562321 75.185001) (xy 145.562332 75.185001) (xy 145.673985 75.174004) (xy 145.817246 75.130547) (xy 145.949275 75.059975) + (xy 146.065 74.965002) (xy 146.088803 74.935999) (xy 147.011003 74.013799) (xy 147.040001 73.990001) (xy 147.134974 73.874276) + (xy 147.205546 73.742247) (xy 147.249003 73.598986) (xy 147.26 73.487333) (xy 147.26 73.487325) (xy 147.263676 73.45) + (xy 147.26 73.412675) (xy 147.26 70.818072) (xy 147.65 70.818072) (xy 147.774482 70.805812) (xy 147.89418 70.769502) + (xy 148.004494 70.710537) (xy 148.101185 70.631185) (xy 148.180537 70.534494) (xy 148.239502 70.42418) (xy 148.275812 70.304482) + (xy 148.288072 70.18) (xy 148.288072 68.18) (xy 148.275812 68.055518) (xy 148.239502 67.93582) (xy 148.180537 67.825506) + (xy 148.101185 67.728815) (xy 148.004494 67.649463) (xy 147.89418 67.590498) (xy 147.774482 67.554188) (xy 147.65 67.541928) + (xy 145.856887 67.541928) (xy 145.984609 67.350779) (xy 146.104089 67.062327) (xy 146.165 66.756109) (xy 146.165 66.443891) + (xy 146.104089 66.137673) (xy 145.984609 65.849221) (xy 145.81115 65.589621) (xy 145.590379 65.36885) (xy 145.330779 65.195391) + (xy 145.042327 65.075911) (xy 144.736109 65.015) (xy 144.423891 65.015) (xy 144.117673 65.075911) (xy 144.023303 65.115) + (xy 143.85374 65.115) (xy 143.566842 65.172068) (xy 143.296589 65.28401) (xy 143.053368 65.446525) (xy 142.846525 65.653368) + (xy 142.68401 65.896589) (xy 142.572068 66.166842) (xy 142.515 66.45374) (xy 142.515 66.74626) (xy 142.572068 67.033158) + (xy 142.607988 67.119876) (xy 142.298698 67.247988) (xy 142.076252 67.396622) (xy 142.081817 67.383186) (xy 142.185 66.864449) + (xy 142.185 66.335551) (xy 142.081817 65.816814) (xy 141.879417 65.328175) (xy 141.585576 64.888412) (xy 141.507164 64.81) + (xy 143.212678 64.81) (xy 143.25 64.813676) (xy 143.287322 64.81) (xy 143.287333 64.81) (xy 143.398986 64.799003) + (xy 143.542247 64.755546) (xy 143.674276 64.684974) (xy 143.790001 64.590001) (xy 143.813804 64.560997) (xy 146.478202 61.8966) + (xy 146.61484 61.8966) (xy 146.77616 61.864511) (xy 146.928121 61.801567) (xy 147.064881 61.710187) (xy 147.181187 61.593881) + (xy 147.272567 61.457121) (xy 147.335511 61.30516) (xy 147.3676 61.14384) (xy 147.3676 60.97936) (xy 147.335511 60.81804) + (xy 147.272567 60.666079) (xy 147.181187 60.529319) (xy 147.064881 60.413013) (xy 146.928121 60.321633) (xy 146.77616 60.258689) + (xy 146.61484 60.2266) (xy 146.45036 60.2266) (xy 146.28904 60.258689) (xy 146.180569 60.303619) (xy 146.089414 60.312597) + (xy 145.946153 60.356054) (xy 145.814124 60.426626) (xy 145.698399 60.521599) (xy 145.674601 60.550597) (xy 142.935199 63.29) + (xy 141.96 63.29) (xy 141.96 63.113072) (xy 142.7 63.113072) (xy 142.824482 63.100812) (xy 142.94418 63.064502) + (xy 143.054494 63.005537) (xy 143.151185 62.926185) (xy 143.230537 62.829494) (xy 143.289502 62.71918) (xy 143.325812 62.599482) + (xy 143.338072 62.475) (xy 143.338072 62.036723) (xy 143.641923 61.732872) (xy 143.745521 61.689961) (xy 143.882281 61.598581) + (xy 143.998587 61.482275) (xy 144.089967 61.345515) (xy 144.152911 61.193554) (xy 144.185 61.032234) (xy 144.185 60.867754) + (xy 144.152911 60.706434) (xy 144.089967 60.554473) (xy 143.998587 60.417713) (xy 143.882281 60.301407) (xy 143.745521 60.210027) + (xy 143.59356 60.147083) (xy 143.43224 60.114994) (xy 143.335 60.114994) (xy 143.335 60.097998) (xy 143.176252 60.097998) + (xy 143.335 59.93925) (xy 143.338072 59.725) (xy 143.325812 59.600518) (xy 143.289502 59.48082) (xy 143.230537 59.370506) + (xy 143.151185 59.273815) (xy 143.054494 59.194463) (xy 142.94418 59.135498) (xy 142.824482 59.099188) (xy 142.7 59.086928) + (xy 142.18575 59.09) (xy 142.027002 59.248748) (xy 142.027002 59.09) (xy 141.96 59.09) (xy 141.96 58.984877) + (xy 141.963435 58.95) (xy 141.949727 58.810816) (xy 141.909128 58.67698) (xy 141.8432 58.553637) (xy 141.754475 58.445525) + (xy 141.646363 58.3568) (xy 141.52302 58.290872) (xy 141.389184 58.250273) (xy 141.284877 58.24) (xy 141.25 58.236565) + (xy 141.215123 58.24) (xy 137.784877 58.24) (xy 137.75 58.236565) (xy 137.715123 58.24) (xy 137.610816 58.250273) + (xy 137.47698 58.290872) (xy 137.353637 58.3568) (xy 137.245525 58.445525) (xy 137.1568 58.553637) (xy 137.090872 58.67698) + (xy 137.050273 58.810816) (xy 137.036565 58.95) (xy 137.040001 58.984887) (xy 137.040001 59.086928) (xy 136.3 59.086928) + (xy 136.175518 59.099188) (xy 136.05582 59.135498) (xy 135.945506 59.194463) (xy 135.848815 59.273815) (xy 135.77598 59.362565) + (xy 135.665313 59.303412) (xy 135.498489 59.252806) (xy 135.324999 59.235719) (xy 135.151509 59.252806) (xy 134.984687 59.303412) + (xy 134.830941 59.38559) (xy 134.729954 59.468468) (xy 134.40495 59.793472) (xy 134.371182 59.821185) (xy 134.343469 59.854953) + (xy 134.343466 59.854956) (xy 134.260588 59.955943) (xy 134.17841 60.109689) (xy 134.127803 60.276512) (xy 134.122311 60.332281) + (xy 134.114998 60.406525) (xy 134.114998 60.406533) (xy 134.110717 60.450002) (xy 134.114998 60.493471) (xy 134.114998 61.218533) + (xy 134.110717 61.262002) (xy 134.114998 61.305471) (xy 134.114998 61.305478) (xy 134.12553 61.412408) (xy 134.127803 61.435492) + (xy 134.136762 61.465025) (xy 134.178409 61.602314) (xy 134.260587 61.75606) (xy 134.371181 61.890819) (xy 134.404954 61.918536) + (xy 134.956466 62.470049) (xy 134.984179 62.503817) (xy 135.017947 62.53153) (xy 135.017949 62.531532) (xy 135.077673 62.580546) + (xy 135.118937 62.614411) (xy 135.272683 62.696589) (xy 135.439506 62.747195) (xy 135.569519 62.76) (xy 135.569529 62.76) + (xy 135.612995 62.764281) (xy 135.656462 62.76) (xy 135.732317 62.76) (xy 135.769463 62.829494) (xy 135.848815 62.926185) + (xy 135.945506 63.005537) (xy 136.05582 63.064502) (xy 136.175518 63.100812) (xy 136.3 63.113072) (xy 137.04 63.113072) + (xy 137.04 63.29) (xy 134.036801 63.29) (xy 133.985804 63.239003) (xy 133.962001 63.209999) (xy 133.846276 63.115026) + (xy 133.714247 63.044454) (xy 133.570986 63.000997) (xy 133.459333 62.99) (xy 133.459322 62.99) (xy 133.422 62.986324) + (xy 133.384678 62.99) (xy 132.864803 62.99) (xy 131.388803 61.514002) (xy 131.365001 61.484999) (xy 131.249276 61.390026) + (xy 131.117247 61.319454) (xy 130.973986 61.275997) (xy 130.902629 61.268969) (xy 130.900812 61.250518) (xy 130.864502 61.13082) + (xy 130.805537 61.020506) (xy 130.726185 60.923815) (xy 130.629494 60.844463) (xy 130.51918 60.785498) (xy 130.399482 60.749188) + (xy 130.275 60.736928) (xy 129.325 60.736928) (xy 129.200518 60.749188) (xy 129.08082 60.785498) (xy 128.970506 60.844463) + (xy 128.873815 60.923815) (xy 128.794463 61.020506) (xy 128.735498 61.13082) (xy 128.699188 61.250518) (xy 128.686928 61.375) + (xy 128.686928 61.64) (xy 128.587155 61.64) (xy 128.531921 61.617121) (xy 128.403801 61.489002) (xy 128.379999 61.459999) + (xy 128.264274 61.365026) (xy 128.132245 61.294454) (xy 127.988984 61.250997) (xy 127.902482 61.242477) (xy 127.900812 61.225518) + (xy 127.864502 61.10582) (xy 127.805537 60.995506) (xy 127.726185 60.898815) (xy 127.629494 60.819463) (xy 127.51918 60.760498) + (xy 127.399482 60.724188) (xy 127.275 60.711928) (xy 126.66 60.711928) (xy 126.66 60.274145) (xy 126.663677 60.236812) + (xy 126.649003 60.087826) (xy 126.605546 59.944565) (xy 126.534974 59.812536) (xy 126.49098 59.758929) (xy 126.440001 59.696811) + (xy 126.411002 59.673013) (xy 125.726991 58.989002) (xy 125.703189 58.959999) (xy 125.587464 58.865026) (xy 125.455435 58.794454) + (xy 125.312174 58.750997) (xy 125.200521 58.74) (xy 125.20051 58.74) (xy 125.163188 58.736324) (xy 125.125866 58.74) + (xy 124.947157 58.74) (xy 124.891922 58.717121) (xy 124.713804 58.539003) (xy 124.690001 58.509999) (xy 124.574276 58.415026) + (xy 124.471331 58.36) (xy 125.362678 58.36) (xy 125.4 58.363676) (xy 125.437322 58.36) (xy 125.437333 58.36) + (xy 125.548986 58.349003) (xy 125.692247 58.305546) (xy 125.824276 58.234974) (xy 125.940001 58.140001) (xy 125.963803 58.110998) + (xy 126.511002 57.5638) (xy 126.540001 57.540001) (xy 126.583557 57.486928) (xy 126.634974 57.424277) (xy 126.705546 57.292247) + (xy 126.718361 57.25) (xy 126.749003 57.148986) (xy 126.76 57.037333) (xy 126.76 57.037324) (xy 126.763676 57.000001) + (xy 126.76 56.962678) (xy 126.76 56.314801) (xy 127.259974 55.814828) (xy 127.129712 56.129308) (xy 127.015 56.706003) + (xy 127.015 57.293997) (xy 127.129712 57.870692) (xy 127.354727 58.413928) (xy 127.681399 58.902826) (xy 128.097174 59.318601) + (xy 128.586072 59.645273) (xy 129.129308 59.870288) (xy 129.706003 59.985) (xy 130.293997 59.985) (xy 130.870692 59.870288) + (xy 131.413928 59.645273) (xy 131.902826 59.318601) (xy 132.318601 58.902826) (xy 132.645273 58.413928) (xy 132.870288 57.870692) + (xy 132.985 57.293997) (xy 132.985 56.706003) (xy 132.948698 56.523499) (xy 134.236201 57.811003) (xy 134.259999 57.840001) + (xy 134.375724 57.934974) (xy 134.507753 58.005546) (xy 134.651014 58.049003) (xy 134.762667 58.06) (xy 134.762675 58.06) + (xy 134.8 58.063676) (xy 134.837325 58.06) (xy 146.152843 58.06) (xy 146.25644 58.102911) (xy 146.41776 58.135) + (xy 146.58224 58.135) (xy 146.74356 58.102911) (xy 146.895521 58.039967) (xy 147.032281 57.948587) (xy 147.148587 57.832281) + (xy 147.239967 57.695521) (xy 147.302911 57.54356) (xy 147.335 57.38224) (xy 147.335 57.21776) (xy 147.302911 57.05644) + (xy 147.239967 56.904479) (xy 147.148587 56.767719) (xy 147.032281 56.651413) (xy 146.895521 56.560033) (xy 146.74356 56.497089) + (xy 146.58224 56.465) (xy 146.41776 56.465) (xy 146.25644 56.497089) (xy 146.152843 56.54) (xy 135.114802 56.54) + (xy 132.832873 54.258072) (xy 134.313271 54.258072) (xy 135.493701 55.438503) (xy 135.517499 55.467501) (xy 135.546497 55.491299) + (xy 135.633223 55.562474) (xy 135.729015 55.613676) (xy 135.765253 55.633046) (xy 135.773549 55.635563) (xy 135.785585 55.69607) + (xy 135.848529 55.848031) (xy 135.939909 55.984791) (xy 136.056215 56.101097) (xy 136.192975 56.192477) (xy 136.344936 56.255421) + (xy 136.506256 56.28751) (xy 136.670736 56.28751) (xy 136.832056 56.255421) (xy 136.935653 56.21251) (xy 144.460168 56.21251) + (xy 144.49749 56.216186) (xy 144.534812 56.21251) (xy 144.534823 56.21251) (xy 144.646476 56.201513) (xy 144.789737 56.158056) + (xy 144.921766 56.087484) (xy 145.037491 55.992511) (xy 145.061294 55.963507) (xy 147.011003 54.013799) (xy 147.040001 53.990001) + (xy 147.134974 53.874276) (xy 147.205546 53.742247) (xy 147.249003 53.598986) (xy 147.26 53.487333) (xy 147.26 53.487323) + (xy 147.263676 53.45) (xy 147.26 53.412677) (xy 147.26 51.718072) (xy 147.65 51.718072) (xy 147.774482 51.705812) + (xy 147.89418 51.669502) (xy 148.004494 51.610537) (xy 148.101185 51.531185) (xy 148.180537 51.434494) (xy 148.239502 51.32418) + (xy 148.275812 51.204482) (xy 148.288072 51.08) (xy 148.288072 49.08) (xy 148.275812 48.955518) (xy 148.239502 48.83582) + (xy 148.180537 48.725506) (xy 148.101185 48.628815) (xy 148.004494 48.549463) (xy 147.89418 48.490498) (xy 147.774482 48.454188) + (xy 147.65 48.441928) (xy 145.856887 48.441928) (xy 145.984609 48.250779) (xy 146.104089 47.962327) (xy 146.165 47.656109) + (xy 146.165 47.343891) (xy 146.104089 47.037673) (xy 145.984609 46.749221) (xy 145.81115 46.489621) (xy 145.590379 46.26885) + (xy 145.330779 46.095391) (xy 145.042327 45.975911) (xy 144.736109 45.915) (xy 144.423891 45.915) (xy 144.117673 45.975911) + (xy 144.023303 46.015) (xy 143.85374 46.015) (xy 143.566842 46.072068) (xy 143.296589 46.18401) (xy 143.053368 46.346525) + (xy 142.846525 46.553368) (xy 142.68401 46.796589) (xy 142.572068 47.066842) (xy 142.515 47.35374) (xy 142.515 47.64626) + (xy 142.572068 47.933158) (xy 142.607988 48.019876) (xy 142.298698 48.147988) (xy 142.076252 48.296622) (xy 142.081817 48.283186) + (xy 142.185 47.764449) (xy 142.185 47.235551) (xy 142.081817 46.716814) (xy 141.879417 46.228175) (xy 141.585576 45.788412) + (xy 141.550903 45.753739) (xy 141.598986 45.749003) (xy 141.742247 45.705546) (xy 141.874276 45.634974) (xy 141.990001 45.540001) + (xy 142.013804 45.510997) (xy 142.410998 45.113803) (xy 142.440001 45.090001) (xy 142.506372 45.009128) (xy 142.534974 44.974277) + (xy 142.605546 44.842247) (xy 142.612373 44.81974) (xy 142.649003 44.698986) (xy 142.66 44.587333) (xy 142.66 44.587324) + (xy 142.663676 44.550001) (xy 142.66 44.512678) (xy 142.66 44.013072) (xy 142.7 44.013072) (xy 142.824482 44.000812) + (xy 142.94418 43.964502) (xy 143.054494 43.905537) (xy 143.151185 43.826185) (xy 143.230537 43.729494) (xy 143.289502 43.61918) + (xy 143.325812 43.499482) (xy 143.338072 43.375) (xy 143.338072 42.767476) (xy 143.532296 42.573251) (xy 143.635894 42.53034) + (xy 143.772654 42.43896) (xy 143.88896 42.322654) (xy 143.98034 42.185894) (xy 144.043284 42.033933) (xy 144.075373 41.872613) + (xy 144.075373 41.708133) (xy 144.043284 41.546813) (xy 143.98034 41.394852) (xy 143.88896 41.258092) (xy 143.772654 41.141786) + (xy 143.635894 41.050406) (xy 143.483933 40.987462) (xy 143.322613 40.955373) (xy 143.218877 40.955373) (xy 143.335 40.83925) + (xy 143.338072 40.625) (xy 143.325812 40.500518) (xy 143.298357 40.410011) (xy 148.999481 40.410011) (xy 149.036803 40.413687) + (xy 149.074125 40.410011) (xy 149.074136 40.410011) (xy 149.185789 40.399014) (xy 149.32905 40.355557) (xy 149.391828 40.322001) + (xy 149.461593 40.322001) + ) + ) + (filled_polygon + (pts + (xy 127.872028 84.28283) (xy 127.78082 84.310498) (xy 127.670506 84.369463) (xy 127.573815 84.448815) (xy 127.494463 84.545506) + (xy 127.435498 84.65582) (xy 127.399188 84.775518) (xy 127.386928 84.9) (xy 127.386928 86.2) (xy 127.399188 86.324482) + (xy 127.435498 86.44418) (xy 127.494463 86.554494) (xy 127.573815 86.651185) (xy 127.670506 86.730537) (xy 127.681212 86.736259) + (xy 127.665 86.81776) (xy 127.665 86.98224) (xy 127.697089 87.14356) (xy 127.74 87.247157) (xy 127.740001 89.041928) + (xy 126.856887 89.041928) (xy 126.984609 88.850779) (xy 127.104089 88.562327) (xy 127.165 88.256109) (xy 127.165 87.943891) + (xy 127.104089 87.637673) (xy 126.984609 87.349221) (xy 126.81115 87.089621) (xy 126.590379 86.86885) (xy 126.330779 86.695391) + (xy 126.042327 86.575911) (xy 125.736109 86.515) (xy 125.423891 86.515) (xy 125.117673 86.575911) (xy 125.023303 86.615) + (xy 124.85374 86.615) (xy 124.566842 86.672068) (xy 124.296589 86.78401) (xy 124.053368 86.946525) (xy 123.846525 87.153368) + (xy 123.68401 87.396589) (xy 123.572068 87.666842) (xy 123.515 87.95374) (xy 123.515 88.24626) (xy 123.572068 88.533158) + (xy 123.607988 88.619876) (xy 123.298698 88.747988) (xy 123.076252 88.896622) (xy 123.081817 88.883186) (xy 123.185 88.364449) + (xy 123.185 87.835551) (xy 123.081817 87.316814) (xy 122.879417 86.828175) (xy 122.585576 86.388412) (xy 122.211588 86.014424) + (xy 121.771825 85.720583) (xy 121.384142 85.56) (xy 122.215123 85.56) (xy 122.25 85.563435) (xy 122.284877 85.56) + (xy 122.369771 85.551639) (xy 122.389184 85.549727) (xy 122.52302 85.509128) (xy 122.646363 85.4432) (xy 122.754475 85.354475) + (xy 122.8432 85.246363) (xy 122.909128 85.12302) (xy 122.949727 84.989184) (xy 122.959145 84.89356) (xy 122.963435 84.85) + (xy 122.96 84.815123) (xy 122.96 84.613072) (xy 123.7 84.613072) (xy 123.824482 84.600812) (xy 123.94418 84.564502) + (xy 124.054494 84.505537) (xy 124.151185 84.426185) (xy 124.230537 84.329494) (xy 124.281046 84.235) (xy 125.047045 84.235) + (xy 125.054479 84.239967) (xy 125.20644 84.302911) (xy 125.36776 84.335) (xy 125.53224 84.335) (xy 125.69356 84.302911) + (xy 125.845521 84.239967) (xy 125.982281 84.148587) (xy 126.098587 84.032281) (xy 126.189967 83.895521) (xy 126.252911 83.74356) + (xy 126.285 83.58224) (xy 126.285 83.41776) (xy 126.252911 83.25644) (xy 126.189967 83.104479) (xy 126.098587 82.967719) + (xy 125.982281 82.851413) (xy 125.845521 82.760033) (xy 125.69356 82.697089) (xy 125.53224 82.665) (xy 125.36776 82.665) + (xy 125.20644 82.697089) (xy 125.163199 82.715) (xy 124.281046 82.715) (xy 124.230537 82.620506) (xy 124.213708 82.6) + (xy 124.230537 82.579494) (xy 124.289502 82.46918) (xy 124.325812 82.349482) (xy 124.338072 82.225) (xy 124.335 82.01075) + (xy 124.17625 81.852) (xy 123.027 81.852) (xy 123.027 81.872) (xy 122.96 81.872) (xy 122.96 81.578) + (xy 123.027 81.578) (xy 123.027 81.598) (xy 124.17625 81.598) (xy 124.335 81.43925) (xy 124.338072 81.225) + (xy 124.325812 81.100518) (xy 124.289502 80.98082) (xy 124.230537 80.870506) (xy 124.151185 80.773815) (xy 124.054494 80.694463) + (xy 123.94418 80.635498) (xy 123.824482 80.599188) (xy 123.7 80.586928) (xy 123.18575 80.59) (xy 123.027002 80.748748) + (xy 123.027002 80.59) (xy 122.96 80.59) (xy 122.96 80.384877) (xy 122.963435 80.35) (xy 122.949727 80.210816) + (xy 122.909128 80.07698) (xy 122.8432 79.953637) (xy 122.754475 79.845525) (xy 122.650262 79.76) (xy 123.349199 79.76) + ) + ) + (filled_polygon + (pts + (xy 115.796183 84.103817) (xy 115.930941 84.214411) (xy 116.084687 84.296589) (xy 116.25151 84.347195) (xy 116.381523 84.36) + (xy 116.381533 84.36) (xy 116.424999 84.364281) (xy 116.468466 84.36) (xy 116.794499 84.36) (xy 116.848815 84.426185) + (xy 116.945506 84.505537) (xy 117.05582 84.564502) (xy 117.175518 84.600812) (xy 117.3 84.613072) (xy 118.04 84.613072) + (xy 118.04 84.815123) (xy 118.036565 84.85) (xy 118.050273 84.989184) (xy 118.090872 85.12302) (xy 118.1568 85.246363) + (xy 118.245525 85.354475) (xy 118.330571 85.42427) (xy 118.353637 85.4432) (xy 118.47698 85.509128) (xy 118.610816 85.549727) + (xy 118.75 85.563435) (xy 118.784877 85.56) (xy 119.615858 85.56) (xy 119.228175 85.720583) (xy 118.788412 86.014424) + (xy 118.414424 86.388412) (xy 118.120583 86.828175) (xy 118.087914 86.907046) (xy 118.032281 86.851413) (xy 117.895521 86.760033) + (xy 117.791925 86.717122) (xy 115.759994 84.685193) (xy 115.759994 84.147157) (xy 115.784063 84.089049) + ) + ) + (filled_polygon + (pts + (xy 103.688351 75.781732) (xy 103.931032 75.882254) (xy 104.06499 75.9089) (xy 104.064991 84.489014) (xy 103.83575 84.49) + (xy 103.677 84.64875) (xy 103.677 85.498) (xy 103.697 85.498) (xy 103.697 85.743928) (xy 103.670049 85.741274) + (xy 103.632727 85.74495) (xy 103.632717 85.74495) (xy 103.521064 85.755947) (xy 103.468144 85.772) (xy 103.423 85.772) + (xy 103.423 85.752) (xy 103.403 85.752) (xy 103.403 85.498) (xy 103.423 85.498) (xy 103.423 84.64875) + (xy 103.26425 84.49) (xy 102.55 84.486928) (xy 102.425518 84.499188) (xy 102.30582 84.535498) (xy 102.195506 84.594463) + (xy 102.13501 84.644111) (xy 102.13501 84.600617) (xy 102.138686 84.563294) (xy 102.13501 84.525971) (xy 102.13501 84.525962) + (xy 102.124013 84.414309) (xy 102.080556 84.271048) (xy 102.0717 84.254479) (xy 102.009984 84.139018) (xy 101.938809 84.052292) + (xy 101.915011 84.023294) (xy 101.886014 83.999497) (xy 98.976499 81.089983) (xy 98.976499 75.907211) (xy 99.108662 75.9335) + (xy 99.371338 75.9335) (xy 99.628968 75.882254) (xy 99.819272 75.803427) (xy 99.819272 76.965994) (xy 99.729215 77.026168) + (xy 99.543475 77.211908) (xy 99.39754 77.430316) (xy 99.297018 77.672997) (xy 99.245772 77.930627) (xy 99.245772 78.193303) + (xy 99.297018 78.450933) (xy 99.39754 78.693614) (xy 99.543475 78.912022) (xy 99.729215 79.097762) (xy 99.862717 79.186965) + (xy 99.729215 79.276168) (xy 99.543475 79.461908) (xy 99.39754 79.680316) (xy 99.297018 79.922997) (xy 99.245772 80.180627) + (xy 99.245772 80.443303) (xy 99.297018 80.700933) (xy 99.39754 80.943614) (xy 99.543475 81.162022) (xy 99.729215 81.347762) + (xy 99.947623 81.493697) (xy 100.190304 81.594219) (xy 100.447934 81.645465) (xy 100.71061 81.645465) (xy 100.96824 81.594219) + (xy 101.210921 81.493697) (xy 101.429329 81.347762) (xy 101.615069 81.162022) (xy 101.643633 81.119272) (xy 101.664203 81.150057) + (xy 101.849943 81.335797) (xy 102.068351 81.481732) (xy 102.311032 81.582254) (xy 102.568662 81.6335) (xy 102.831338 81.6335) + (xy 103.088968 81.582254) (xy 103.331649 81.481732) (xy 103.550057 81.335797) (xy 103.735797 81.150057) (xy 103.881732 80.931649) + (xy 103.982254 80.688968) (xy 104.0335 80.431338) (xy 104.0335 80.168662) (xy 103.982254 79.911032) (xy 103.881732 79.668351) + (xy 103.735797 79.449943) (xy 103.550057 79.264203) (xy 103.45397 79.2) (xy 103.550057 79.135797) (xy 103.735797 78.950057) + (xy 103.881732 78.731649) (xy 103.982254 78.488968) (xy 104.0335 78.231338) (xy 104.0335 77.968662) (xy 103.982254 77.711032) + (xy 103.881732 77.468351) (xy 103.735797 77.249943) (xy 103.550057 77.064203) (xy 103.394136 76.96002) (xy 103.438475 76.905993) + (xy 103.509047 76.773964) (xy 103.552504 76.630703) (xy 103.563501 76.51905) (xy 103.563501 76.51904) (xy 103.567177 76.481717) + (xy 103.563501 76.444394) (xy 103.563501 75.69831) + ) + ) + (filled_polygon + (pts + (xy 218.227 83.998) (xy 218.247 83.998) (xy 218.247 84.252) (xy 218.227 84.252) (xy 218.227 84.272) + (xy 218.16 84.272) (xy 218.16 83.978) (xy 218.227 83.978) + ) + ) + (filled_polygon + (pts + (xy 199.227 83.998) (xy 199.247 83.998) (xy 199.247 84.252) (xy 199.227 84.252) (xy 199.227 84.272) + (xy 199.16 84.272) (xy 199.16 83.978) (xy 199.227 83.978) + ) + ) + (filled_polygon + (pts + (xy 110.210096 73.165103) (xy 109.989003 73.386196) (xy 109.959999 73.409999) (xy 109.906061 73.475723) (xy 109.865026 73.525724) + (xy 109.821944 73.606324) (xy 109.794454 73.657754) (xy 109.750997 73.801015) (xy 109.74 73.912668) (xy 109.74 73.912678) + (xy 109.736324 73.95) (xy 109.74 73.987323) (xy 109.740001 77.84) (xy 109.300072 77.84) (xy 109.300072 77.838) + (xy 109.287812 77.713518) (xy 109.251502 77.59382) (xy 109.192537 77.483506) (xy 109.113185 77.386815) (xy 109.016494 77.307463) + (xy 109.002532 77.3) (xy 109.016494 77.292537) (xy 109.113185 77.213185) (xy 109.192537 77.116494) (xy 109.251502 77.00618) + (xy 109.287812 76.886482) (xy 109.300072 76.762) (xy 109.297 76.28575) (xy 109.13825 76.127) (xy 108.027 76.127) + (xy 108.027 76.147) (xy 107.773 76.147) (xy 107.773 76.127) (xy 106.66175 76.127) (xy 106.503 76.28575) + (xy 106.499928 76.762) (xy 106.512188 76.886482) (xy 106.548498 77.00618) (xy 106.607463 77.116494) (xy 106.686815 77.213185) + (xy 106.783506 77.292537) (xy 106.797468 77.3) (xy 106.783506 77.307463) (xy 106.686815 77.386815) (xy 106.607463 77.483506) + (xy 106.548498 77.59382) (xy 106.512188 77.713518) (xy 106.499928 77.838) (xy 106.499928 79.362) (xy 106.512188 79.486482) + (xy 106.548498 79.60618) (xy 106.607463 79.716494) (xy 106.686815 79.813185) (xy 106.731674 79.85) (xy 106.686815 79.886815) + (xy 106.607463 79.983506) (xy 106.548498 80.09382) (xy 106.512188 80.213518) (xy 106.499928 80.338) (xy 106.499928 81.862) + (xy 106.505882 81.92245) (xy 106.451509 81.927805) (xy 106.284686 81.978411) (xy 106.130941 82.060589) (xy 106.029953 82.143468) + (xy 105.804952 82.368469) (xy 105.771184 82.396182) (xy 105.743471 82.42995) (xy 105.743468 82.429953) (xy 105.66059 82.53094) + (xy 105.58499 82.672379) (xy 105.58499 75.924593) (xy 105.854503 75.655081) (xy 105.883502 75.631282) (xy 105.978475 75.515557) + (xy 106.049047 75.383528) (xy 106.092504 75.240267) (xy 106.092727 75.238) (xy 106.499928 75.238) (xy 106.503 75.71425) + (xy 106.66175 75.873) (xy 107.773 75.873) (xy 107.773 74.76175) (xy 108.027 74.76175) (xy 108.027 75.873) + (xy 109.13825 75.873) (xy 109.297 75.71425) (xy 109.300072 75.238) (xy 109.287812 75.113518) (xy 109.251502 74.99382) + (xy 109.192537 74.883506) (xy 109.113185 74.786815) (xy 109.016494 74.707463) (xy 108.90618 74.648498) (xy 108.786482 74.612188) + (xy 108.662 74.599928) (xy 108.18575 74.603) (xy 108.027 74.76175) (xy 107.773 74.76175) (xy 107.61425 74.603) + (xy 107.138 74.599928) (xy 107.013518 74.612188) (xy 106.89382 74.648498) (xy 106.783506 74.707463) (xy 106.686815 74.786815) + (xy 106.607463 74.883506) (xy 106.548498 74.99382) (xy 106.512188 75.113518) (xy 106.499928 75.238) (xy 106.092727 75.238) + (xy 106.103501 75.128614) (xy 106.103501 75.128605) (xy 106.107177 75.091282) (xy 106.103501 75.053959) (xy 106.103501 74.146041) + (xy 106.107177 74.108718) (xy 106.103501 74.071396) (xy 106.103501 74.071386) (xy 106.092504 73.959733) (xy 106.049047 73.816472) + (xy 105.978475 73.684443) (xy 105.96 73.661931) (xy 105.96 70.634802) (xy 106.2062 70.881002) (xy 106.229999 70.910001) + (xy 106.345724 71.004974) (xy 106.477753 71.075546) (xy 106.621014 71.119003) (xy 106.732667 71.13) (xy 106.732675 71.13) + (xy 106.77 71.133676) (xy 106.807325 71.13) (xy 107.549317 71.13) (xy 107.633695 71.25628) (xy 107.82828 71.450865) + (xy 108.057088 71.60375) (xy 108.311325 71.709059) (xy 108.581223 71.762745) (xy 108.856407 71.762745) (xy 109.126305 71.709059) + (xy 109.380542 71.60375) (xy 109.60935 71.450865) (xy 109.803935 71.25628) (xy 109.95682 71.027472) (xy 110.062129 70.773235) + (xy 110.115815 70.503337) (xy 110.115815 70.228153) (xy 110.062129 69.958255) (xy 110.050425 69.93) (xy 110.210096 69.93) + ) + ) + (filled_polygon + (pts + (xy 142.027 79.098) (xy 142.047 79.098) (xy 142.047 79.352) (xy 142.027 79.352) (xy 142.027 79.372) + (xy 141.96 79.372) (xy 141.96 79.078) (xy 142.027 79.078) + ) + ) + (filled_polygon + (pts + (xy 161.127 76.688) (xy 161.147 76.688) (xy 161.147 76.942) (xy 161.127 76.942) (xy 161.127 76.962) + (xy 161.06 76.962) (xy 161.06 76.668) (xy 161.127 76.668) + ) + ) + (filled_polygon + (pts + (xy 114.936189 67.236001) (xy 114.959988 67.265) (xy 115.075713 67.359973) (xy 115.207742 67.430545) (xy 115.351003 67.474002) + (xy 115.462656 67.484999) (xy 115.462666 67.484999) (xy 115.499989 67.488675) (xy 115.537312 67.484999) (xy 118.349886 67.484999) + (xy 118.120583 67.828175) (xy 117.918183 68.316814) (xy 117.815 68.835551) (xy 117.815 69.364449) (xy 117.918183 69.883186) + (xy 117.923749 69.896623) (xy 117.701302 69.747989) (xy 117.392012 69.619877) (xy 117.427932 69.533158) (xy 117.485 69.24626) + (xy 117.485 68.95374) (xy 117.427932 68.666842) (xy 117.31599 68.396589) (xy 117.153475 68.153368) (xy 116.946632 67.946525) + (xy 116.703411 67.78401) (xy 116.433158 67.672068) (xy 116.14626 67.615) (xy 115.976697 67.615) (xy 115.882327 67.575911) + (xy 115.576109 67.515) (xy 115.263891 67.515) (xy 114.957673 67.575911) (xy 114.669221 67.695391) (xy 114.409621 67.86885) + (xy 114.18885 68.089621) (xy 114.015391 68.349221) (xy 113.895911 68.637673) (xy 113.835 68.943891) (xy 113.835 69.256109) + (xy 113.895911 69.562327) (xy 114.015391 69.850779) (xy 114.18885 70.110379) (xy 114.409621 70.33115) (xy 114.669221 70.504609) + (xy 114.835016 70.573283) (xy 114.797988 70.628699) (xy 114.637047 71.017245) (xy 114.555 71.429722) (xy 114.555 71.85028) + (xy 114.637047 72.262757) (xy 114.769252 72.581928) (xy 113.65 72.581928) (xy 113.525518 72.594188) (xy 113.40582 72.630498) + (xy 113.295506 72.689463) (xy 113.198815 72.768815) (xy 113.119463 72.865506) (xy 113.060498 72.97582) (xy 113.024188 73.095518) + (xy 113.011928 73.22) (xy 113.011928 73.46) (xy 112.404437 73.46) (xy 112.404437 69.51058) (xy 112.452906 69.393565) + (xy 112.484995 69.232245) (xy 112.484995 69.067765) (xy 112.452906 68.906445) (xy 112.389962 68.754484) (xy 112.298582 68.617724) + (xy 112.182276 68.501418) (xy 112.045516 68.410038) (xy 111.893555 68.347094) (xy 111.732235 68.315005) (xy 111.730095 68.315005) + (xy 111.730095 64.029906) + ) + ) + (filled_polygon + (pts + (xy 95.56 69.01887) (xy 95.56 68.926622) (xy 95.652248 68.926622) + ) + ) + (filled_polygon + (pts + (xy 96.827 68.67262) (xy 96.847 68.67262) (xy 96.847 68.844808) (xy 96.553 68.844808) (xy 96.553 68.67262) + (xy 96.573 68.67262) (xy 96.573 68.65262) (xy 96.827 68.65262) + ) + ) + (filled_polygon + (pts + (xy 198.228698 59.372012) (xy 198.284017 59.394926) (xy 198.248815 59.423815) (xy 198.169463 59.520506) (xy 198.110498 59.63082) + (xy 198.074188 59.750518) (xy 198.061928 59.875) (xy 198.061928 60.875) (xy 198.074188 60.999482) (xy 198.110498 61.11918) + (xy 198.169463 61.229494) (xy 198.186292 61.25) (xy 198.169463 61.270506) (xy 198.110498 61.38082) (xy 198.074188 61.500518) + (xy 198.061928 61.625) (xy 198.065 61.83925) (xy 198.22375 61.998) (xy 199.573 61.998) (xy 199.573 61.978) + (xy 199.827 61.978) (xy 199.827 61.998) (xy 201.023872 61.998) (xy 201.15644 62.052911) (xy 201.31776 62.085) + (xy 201.48224 62.085) (xy 201.64356 62.052911) (xy 201.795521 61.989967) (xy 201.932281 61.898587) (xy 201.935511 61.895357) + (xy 201.935511 64.777042) (xy 201.93123 64.820511) (xy 201.935511 64.86398) (xy 201.935511 64.863987) (xy 201.946114 64.971638) + (xy 201.948316 64.994001) (xy 201.960753 65.034999) (xy 201.998922 65.160823) (xy 202.0811 65.314569) (xy 202.191694 65.449328) + (xy 202.225467 65.477045) (xy 205.29 68.541579) (xy 205.29 68.815) (xy 202.134801 68.815) (xy 202.856923 68.092878) + (xy 202.960521 68.049967) (xy 203.097281 67.958587) (xy 203.213587 67.842281) (xy 203.304967 67.705521) (xy 203.367911 67.55356) + (xy 203.4 67.39224) (xy 203.4 67.22776) (xy 203.367911 67.06644) (xy 203.304967 66.914479) (xy 203.213587 66.777719) + (xy 203.097281 66.661413) (xy 202.960521 66.570033) (xy 202.80856 66.507089) (xy 202.64724 66.475) (xy 202.48276 66.475) + (xy 202.32144 66.507089) (xy 202.169479 66.570033) (xy 202.032719 66.661413) (xy 201.916413 66.777719) (xy 201.825033 66.914479) + (xy 201.782122 67.018077) (xy 201.210199 67.59) (xy 200.997157 67.59) (xy 200.89356 67.547089) (xy 200.73224 67.515) + (xy 200.56776 67.515) (xy 200.417981 67.544793) (xy 200.430537 67.529494) (xy 200.489502 67.41918) (xy 200.50056 67.382726) + (xy 200.507747 67.380546) (xy 200.639776 67.309974) (xy 200.755501 67.215001) (xy 200.779303 67.185998) (xy 201.161007 66.804295) + (xy 201.190005 66.780497) (xy 201.284978 66.664772) (xy 201.35555 66.532743) (xy 201.389282 66.421543) (xy 201.389971 66.420511) + (xy 201.452915 66.26855) (xy 201.485004 66.10723) (xy 201.485004 65.94275) (xy 201.452915 65.78143) (xy 201.389971 65.629469) + (xy 201.298591 65.492709) (xy 201.182285 65.376403) (xy 201.045525 65.285023) (xy 200.893564 65.222079) (xy 200.732244 65.18999) + (xy 200.567764 65.18999) (xy 200.52312 65.19887) (xy 200.37625 65.052) (xy 199.227 65.052) (xy 199.227 65.072) + (xy 199.16 65.072) (xy 199.16 64.778) (xy 199.227 64.778) (xy 199.227 64.798) (xy 200.37625 64.798) + (xy 200.535 64.63925) (xy 200.538072 64.425) (xy 200.525812 64.300518) (xy 200.489502 64.18082) (xy 200.430537 64.070506) + (xy 200.351185 63.973815) (xy 200.254494 63.894463) (xy 200.14418 63.835498) (xy 200.024482 63.799188) (xy 199.9 63.786928) + (xy 199.38575 63.79) (xy 199.227002 63.948748) (xy 199.227002 63.79) (xy 199.16 63.79) (xy 199.16 63.584877) + (xy 199.163435 63.55) (xy 199.149727 63.410816) (xy 199.109128 63.27698) (xy 199.100773 63.261348) (xy 199.41425 63.26) + (xy 199.573 63.10125) (xy 199.573 62.252) (xy 199.827 62.252) (xy 199.827 63.10125) (xy 199.98575 63.26) + (xy 200.7 63.263072) (xy 200.824482 63.250812) (xy 200.94418 63.214502) (xy 201.054494 63.155537) (xy 201.151185 63.076185) + (xy 201.230537 62.979494) (xy 201.289502 62.86918) (xy 201.325812 62.749482) (xy 201.338072 62.625) (xy 201.335 62.41075) + (xy 201.17625 62.252) (xy 199.827 62.252) (xy 199.573 62.252) (xy 198.22375 62.252) (xy 198.065 62.41075) + (xy 198.061928 62.625) (xy 198.074188 62.749482) (xy 198.101646 62.84) (xy 197.956893 62.84) (xy 197.980547 62.795746) + (xy 197.98714 62.77401) (xy 198.024004 62.652485) (xy 198.035001 62.540832) (xy 198.035001 62.540822) (xy 198.038677 62.503499) + (xy 198.035001 62.466176) (xy 198.035001 59.242588) + ) + ) + (filled_polygon + (pts + (xy 110.210096 68.299761) (xy 110.201534 68.301464) (xy 110.049573 68.364408) (xy 109.991807 68.403006) (xy 110.062129 68.233235) + (xy 110.115815 67.963337) (xy 110.115815 67.688153) (xy 110.062129 67.418255) (xy 109.95682 67.164018) (xy 109.803935 66.93521) + (xy 109.60935 66.740625) (xy 109.380542 66.58774) (xy 109.3033 66.555745) (xy 109.380542 66.52375) (xy 109.60935 66.370865) + (xy 109.803935 66.17628) (xy 109.95682 65.947472) (xy 110.062129 65.693235) (xy 110.115815 65.423337) (xy 110.115815 65.148153) + (xy 110.062129 64.878255) (xy 109.95682 64.624018) (xy 109.803935 64.39521) (xy 109.60935 64.200625) (xy 109.380542 64.04774) + (xy 109.3033 64.015745) (xy 109.380542 63.98375) (xy 109.60935 63.830865) (xy 109.803935 63.63628) (xy 109.95682 63.407472) + (xy 110.062129 63.153235) (xy 110.115815 62.883337) (xy 110.115815 62.608153) (xy 110.062129 62.338255) (xy 109.95682 62.084018) + (xy 109.803935 61.85521) (xy 109.60935 61.660625) (xy 109.380542 61.50774) (xy 109.3033 61.475745) (xy 109.380542 61.44375) + (xy 109.60935 61.290865) (xy 109.803935 61.09628) (xy 109.95682 60.867472) (xy 110.062129 60.613235) (xy 110.115815 60.343337) + (xy 110.115815 60.068153) (xy 110.062129 59.798255) (xy 109.95682 59.544018) (xy 109.803935 59.31521) (xy 109.60935 59.120625) + (xy 109.380542 58.96774) (xy 109.3033 58.935745) (xy 109.380542 58.90375) (xy 109.60935 58.750865) (xy 109.803935 58.55628) + (xy 109.95682 58.327472) (xy 110.062129 58.073235) (xy 110.115815 57.803337) (xy 110.115815 57.528153) (xy 110.062129 57.258255) + (xy 109.95682 57.004018) (xy 109.803935 56.77521) (xy 109.60935 56.580625) (xy 109.380542 56.42774) (xy 109.3033 56.395745) + (xy 109.380542 56.36375) (xy 109.60935 56.210865) (xy 109.803935 56.01628) (xy 109.95682 55.787472) (xy 110.062129 55.533235) + (xy 110.115815 55.263337) (xy 110.115815 54.988153) (xy 110.062129 54.718255) (xy 109.95682 54.464018) (xy 109.803935 54.23521) + (xy 109.60935 54.040625) (xy 109.380542 53.88774) (xy 109.3033 53.855745) (xy 109.380542 53.82375) (xy 109.60935 53.670865) + (xy 109.803935 53.47628) (xy 109.95682 53.247472) (xy 110.062129 52.993235) (xy 110.115815 52.723337) (xy 110.115815 52.448153) + (xy 110.062129 52.178255) (xy 109.95682 51.924018) (xy 109.803935 51.69521) (xy 109.60935 51.500625) (xy 109.380542 51.34774) + (xy 109.308872 51.318053) (xy 109.321838 51.313381) (xy 109.437795 51.251401) (xy 109.504775 51.01131) (xy 108.718815 50.22535) + (xy 108.704673 50.239493) (xy 108.525068 50.059888) (xy 108.53921 50.045745) (xy 108.525068 50.031603) (xy 108.704673 49.851998) + (xy 108.718815 49.86614) (xy 108.732958 49.851998) (xy 108.912563 50.031603) (xy 108.89842 50.045745) (xy 109.68438 50.831705) + (xy 109.924471 50.764725) (xy 110.041571 50.515697) (xy 110.107838 50.24861) (xy 110.120725 49.973728) (xy 110.079737 49.701612) + (xy 110.005347 49.495163) (xy 110.045073 49.462561) (xy 110.07279 49.428788) (xy 110.210095 49.291483) + ) + ) + (filled_polygon + (pts + (xy 102.163998 40.490556) (xy 102.135 40.514354) (xy 102.111202 40.543352) (xy 102.111201 40.543353) (xy 102.040026 40.630079) + (xy 101.969454 40.762109) (xy 101.93433 40.877901) (xy 101.925998 40.905369) (xy 101.915198 41.015027) (xy 101.911324 41.054355) + (xy 101.915001 41.091688) (xy 101.915 53.467114) (xy 101.848587 53.367719) (xy 101.732281 53.251413) (xy 101.595521 53.160033) + (xy 101.44356 53.097089) (xy 101.285008 53.065551) (xy 101.285008 50.089218) (xy 101.289289 50.045752) (xy 101.285008 50.002286) + (xy 101.285008 50.002276) (xy 101.272203 49.872263) (xy 101.221597 49.70544) (xy 101.139419 49.551694) (xy 101.028825 49.416936) + (xy 100.995052 49.389219) (xy 100.995046 49.389213) (xy 100.894059 49.306335) (xy 100.740313 49.224157) (xy 100.57349 49.17355) + (xy 100.4 49.156464) (xy 100.22651 49.17355) (xy 100.059687 49.224157) (xy 99.905941 49.306335) (xy 99.771183 49.416928) + (xy 99.66059 49.551686) (xy 99.578412 49.705432) (xy 99.527805 49.872255) (xy 99.510719 50.045745) (xy 99.515009 50.089305) + (xy 99.515008 67.844048) (xy 98.976499 67.844048) (xy 98.976499 53.481144) (xy 99.025252 53.432391) (xy 99.054256 53.408588) + (xy 99.149229 53.292863) (xy 99.219801 53.160834) (xy 99.229454 53.129011) (xy 99.263258 53.017573) (xy 99.270768 52.941319) + (xy 99.317166 52.829305) (xy 99.349255 52.667985) (xy 99.349255 52.503505) (xy 99.317166 52.342185) (xy 99.254222 52.190224) + (xy 99.162842 52.053464) (xy 99.046536 51.937158) (xy 98.909776 51.845778) (xy 98.757815 51.782834) (xy 98.596495 51.750745) + (xy 98.432015 51.750745) (xy 98.270695 51.782834) (xy 98.118734 51.845778) (xy 97.981974 51.937158) (xy 97.865668 52.053464) + (xy 97.774288 52.190224) (xy 97.711344 52.342185) (xy 97.679255 52.503505) (xy 97.679255 52.624079) (xy 97.676498 52.626342) + (xy 97.62485 52.689276) (xy 97.581525 52.742067) (xy 97.534895 52.829305) (xy 97.510953 52.874097) (xy 97.467496 53.017358) + (xy 97.456499 53.129011) (xy 97.456499 53.129021) (xy 97.452823 53.166343) (xy 97.456499 53.203665) (xy 97.4565 67.874666) + (xy 97.395982 67.856308) (xy 97.2715 67.844048) (xy 96.98575 67.84712) (xy 96.870155 67.962715) (xy 96.885 67.888087) + (xy 96.885 67.723607) (xy 96.852911 67.562287) (xy 96.81 67.45869) (xy 96.81 51.83037) (xy 96.839967 51.785521) + (xy 96.902911 51.63356) (xy 96.935 51.47224) (xy 96.935 51.30776) (xy 96.902911 51.14644) (xy 96.839967 50.994479) + (xy 96.748587 50.857719) (xy 96.632281 50.741413) (xy 96.495521 50.650033) (xy 96.34356 50.587089) (xy 96.18224 50.555) + (xy 96.01776 50.555) (xy 95.85644 50.587089) (xy 95.704479 50.650033) (xy 95.567719 50.741413) (xy 95.56 50.749132) + (xy 95.56 44.896884) (xy 95.632281 44.848587) (xy 95.748587 44.732281) (xy 95.839967 44.595521) (xy 95.902911 44.44356) + (xy 95.935 44.28224) (xy 95.935 44.11776) (xy 95.902911 43.95644) (xy 95.839967 43.804479) (xy 95.748587 43.667719) + (xy 95.632281 43.551413) (xy 95.495521 43.460033) (xy 95.34356 43.397089) (xy 95.18224 43.365) (xy 95.01776 43.365) + (xy 94.85644 43.397089) (xy 94.704479 43.460033) (xy 94.567719 43.551413) (xy 94.451413 43.667719) (xy 94.360033 43.804479) + (xy 94.317121 43.908078) (xy 94.289003 43.936196) (xy 94.259999 43.959999) (xy 94.255198 43.96585) (xy 94.197795 43.760089) + (xy 94.062055 43.69626) (xy 94.140542 43.66375) (xy 94.36935 43.510865) (xy 94.563935 43.31628) (xy 94.71682 43.087472) + (xy 94.822129 42.833235) (xy 94.875815 42.563337) (xy 94.875815 42.288153) (xy 94.822129 42.018255) (xy 94.71682 41.764018) + (xy 94.563935 41.53521) (xy 94.36935 41.340625) (xy 94.140542 41.18774) (xy 93.886305 41.082431) (xy 93.616407 41.028745) + (xy 93.564337 41.028745) (xy 93.523314 40.82251) (xy 93.418005 40.568273) (xy 93.26512 40.339465) (xy 93.070535 40.14488) + (xy 92.841727 39.991995) (xy 92.58749 39.886686) (xy 92.317592 39.833) (xy 92.042408 39.833) (xy 91.77251 39.886686) + (xy 91.518273 39.991995) (xy 91.289465 40.14488) (xy 91.09488 40.339465) (xy 90.941995 40.568273) (xy 90.836686 40.82251) + (xy 90.783 41.092408) (xy 90.783 41.367592) (xy 90.836686 41.63749) (xy 90.941995 41.891727) (xy 91.09488 42.120535) + (xy 91.289465 42.31512) (xy 91.518273 42.468005) (xy 91.595515 42.5) (xy 91.518273 42.531995) (xy 91.289465 42.68488) + (xy 91.09488 42.879465) (xy 90.941995 43.108273) (xy 90.836686 43.36251) (xy 90.783 43.632408) (xy 90.783 43.907592) + (xy 90.836686 44.17749) (xy 90.941995 44.431727) (xy 91.09488 44.660535) (xy 91.289465 44.85512) (xy 91.518273 45.008005) + (xy 91.589943 45.037692) (xy 91.576977 45.042364) (xy 91.46102 45.104344) (xy 91.39404 45.344435) (xy 92.18 46.130395) + (xy 92.96596 45.344435) (xy 92.956048 45.308907) (xy 93.29921 44.965745) (xy 93.285068 44.951603) (xy 93.464673 44.771998) + (xy 93.478815 44.78614) (xy 93.492958 44.771998) (xy 93.672563 44.951603) (xy 93.65842 44.965745) (xy 93.672563 44.979888) + (xy 93.492958 45.159493) (xy 93.478815 45.14535) (xy 92.692855 45.93131) (xy 92.702767 45.966838) (xy 92.359605 46.31) + (xy 92.373748 46.324143) (xy 92.194143 46.503748) (xy 92.18 46.489605) (xy 92.165858 46.503748) (xy 91.986253 46.324143) + (xy 92.000395 46.31) (xy 91.214435 45.52404) (xy 90.974344 45.59102) (xy 90.857244 45.840048) (xy 90.790977 46.107135) + (xy 90.77809 46.382017) (xy 90.819078 46.654133) (xy 90.912364 46.913023) (xy 90.974344 47.02898) (xy 91.214433 47.095959) + (xy 91.098023 47.212369) (xy 91.113917 47.228263) (xy 91.094444 47.251991) (xy 88.959058 49.387379) (xy 88.958857 38.511863) + (xy 88.971894 38.382509) (xy 88.998593 38.296493) (xy 89.041067 38.218238) (xy 89.097851 38.149414) (xy 89.16667 38.092633) + (xy 89.244936 38.05015) (xy 89.33096 38.023445) (xy 89.473606 38.009063) (xy 105.261763 37.392791) + ) + ) + (filled_polygon + (pts + (xy 168.386928 62.525) (xy 168.399188 62.649482) (xy 168.421668 62.723587) (xy 168.352441 62.760589) (xy 168.333363 62.776246) + (xy 168.251453 62.843468) (xy 168.251451 62.84347) (xy 168.217683 62.871183) (xy 168.18997 62.904951) (xy 166.654951 64.439971) + (xy 166.621184 64.467683) (xy 166.593471 64.501451) (xy 166.593468 64.501454) (xy 166.51059 64.602441) (xy 166.428412 64.756187) + (xy 166.377805 64.92301) (xy 166.367078 65.031928) (xy 164.956887 65.031928) (xy 165.084609 64.840779) (xy 165.204089 64.552327) + (xy 165.265 64.246109) (xy 165.265 63.933891) (xy 165.204089 63.627673) (xy 165.084609 63.339221) (xy 164.91115 63.079621) + (xy 164.690379 62.85885) (xy 164.430779 62.685391) (xy 164.142327 62.565911) (xy 163.836109 62.505) (xy 163.523891 62.505) + (xy 163.217673 62.565911) (xy 163.123303 62.605) (xy 162.95374 62.605) (xy 162.666842 62.662068) (xy 162.396589 62.77401) + (xy 162.153368 62.936525) (xy 161.946525 63.143368) (xy 161.78401 63.386589) (xy 161.672068 63.656842) (xy 161.615 63.94374) + (xy 161.615 64.23626) (xy 161.672068 64.523158) (xy 161.707988 64.609876) (xy 161.398698 64.737988) (xy 161.176252 64.886622) + (xy 161.181817 64.873186) (xy 161.285 64.354449) (xy 161.285 63.825551) (xy 161.181817 63.306814) (xy 160.979417 62.818175) + (xy 160.685576 62.378412) (xy 160.535164 62.228) (xy 168.386928 62.228) + ) + ) + (filled_polygon + (pts + (xy 117.907753 40.944454) (xy 117.775724 41.015026) (xy 117.775722 41.015027) (xy 117.775723 41.015027) (xy 117.688996 41.086201) + (xy 117.688992 41.086205) (xy 117.659999 41.109999) (xy 117.636205 41.138992) (xy 116.108077 42.667121) (xy 116.004479 42.710033) + (xy 115.867719 42.801413) (xy 115.751413 42.917719) (xy 115.660033 43.054479) (xy 115.597089 43.20644) (xy 115.565 43.36776) + (xy 115.565 43.53224) (xy 115.597089 43.69356) (xy 115.603299 43.708552) (xy 115.505941 43.76059) (xy 115.371183 43.871183) + (xy 115.26059 44.005941) (xy 115.178412 44.159687) (xy 115.127805 44.32651) (xy 115.110719 44.5) (xy 115.127805 44.67349) + (xy 115.178412 44.840313) (xy 115.26059 44.994059) (xy 115.343468 45.095046) (xy 116.21847 45.970049) (xy 116.246183 46.003817) + (xy 116.279951 46.03153) (xy 116.279953 46.031532) (xy 116.368054 46.103835) (xy 116.380941 46.114411) (xy 116.534687 46.196589) + (xy 116.70151 46.247195) (xy 116.791243 46.256033) (xy 116.848815 46.326185) (xy 116.945506 46.405537) (xy 117.05582 46.464502) + (xy 117.175518 46.500812) (xy 117.3 46.513072) (xy 118.04 46.513072) (xy 118.04 46.715123) (xy 118.036565 46.75) + (xy 118.050273 46.889184) (xy 118.090872 47.02302) (xy 118.1568 47.146363) (xy 118.245525 47.254475) (xy 118.343645 47.335) + (xy 118.353637 47.3432) (xy 118.47698 47.409128) (xy 118.610816 47.449727) (xy 118.75 47.463435) (xy 118.784877 47.46) + (xy 119.615858 47.46) (xy 119.228175 47.620583) (xy 118.788412 47.914424) (xy 118.414424 48.288412) (xy 118.120583 48.728175) + (xy 117.918183 49.216814) (xy 117.815 49.735551) (xy 117.815 50.264449) (xy 117.918183 50.783186) (xy 117.923749 50.796623) + (xy 117.701302 50.647989) (xy 117.392012 50.519877) (xy 117.427932 50.433158) (xy 117.485 50.14626) (xy 117.485 49.85374) + (xy 117.427932 49.566842) (xy 117.31599 49.296589) (xy 117.153475 49.053368) (xy 116.946632 48.846525) (xy 116.703411 48.68401) + (xy 116.433158 48.572068) (xy 116.14626 48.515) (xy 115.976697 48.515) (xy 115.882327 48.475911) (xy 115.576109 48.415) + (xy 115.263891 48.415) (xy 114.957673 48.475911) (xy 114.669221 48.595391) (xy 114.409621 48.76885) (xy 114.18885 48.989621) + (xy 114.015391 49.249221) (xy 113.895911 49.537673) (xy 113.835 49.843891) (xy 113.835 50.156109) (xy 113.895911 50.462327) + (xy 114.015391 50.750779) (xy 114.18885 51.010379) (xy 114.409621 51.23115) (xy 114.669221 51.404609) (xy 114.835016 51.473283) + (xy 114.797988 51.528699) (xy 114.637047 51.917245) (xy 114.555 52.329722) (xy 114.555 52.75028) (xy 114.637047 53.162757) + (xy 114.769252 53.481928) (xy 113.65 53.481928) (xy 113.525518 53.494188) (xy 113.40582 53.530498) (xy 113.295506 53.589463) + (xy 113.198815 53.668815) (xy 113.119463 53.765506) (xy 113.060498 53.87582) (xy 113.024188 53.995518) (xy 113.011928 54.12) + (xy 113.011928 56.12) (xy 113.024188 56.244482) (xy 113.060498 56.36418) (xy 113.119463 56.474494) (xy 113.198815 56.571185) + (xy 113.295506 56.650537) (xy 113.40582 56.709502) (xy 113.525518 56.745812) (xy 113.65 56.758072) (xy 113.9531 56.758072) + (xy 114.010033 56.895521) (xy 114.101413 57.032281) (xy 114.217719 57.148587) (xy 114.354479 57.239967) (xy 114.50644 57.302911) + (xy 114.66776 57.335) (xy 114.83224 57.335) (xy 114.99356 57.302911) (xy 115.040862 57.283318) (xy 115.036197 57.289002) + (xy 114.713988 57.611211) (xy 114.68499 57.635009) (xy 114.661192 57.664007) (xy 114.661191 57.664008) (xy 114.590016 57.750734) + (xy 114.519444 57.882764) (xy 114.497367 57.955546) (xy 114.475988 58.026024) (xy 114.468415 58.102911) (xy 114.461314 58.17501) + (xy 114.464991 58.212342) (xy 114.46499 64.437667) (xy 114.461314 64.47499) (xy 114.46499 64.512312) (xy 114.46499 64.512322) + (xy 114.475987 64.623975) (xy 114.476954 64.627162) (xy 112.357869 62.508078) (xy 112.314957 62.404479) (xy 112.223577 62.267719) + (xy 112.107271 62.151413) (xy 111.970511 62.060033) (xy 111.81855 61.997089) (xy 111.730095 61.979494) (xy 111.730095 59.781674) + (xy 112.404953 60.456532) (xy 112.50594 60.53941) (xy 112.659686 60.621588) (xy 112.826509 60.672194) (xy 112.999999 60.689281) + (xy 113.173489 60.672194) (xy 113.340313 60.621588) (xy 113.494058 60.53941) (xy 113.628817 60.428817) (xy 113.73941 60.294058) + (xy 113.821588 60.140313) (xy 113.872194 59.973489) (xy 113.889281 59.799999) (xy 113.872194 59.626509) (xy 113.821588 59.459686) + (xy 113.73941 59.30594) (xy 113.656532 59.204953) (xy 112.535 58.083422) (xy 112.535 46.886993) (xy 112.546588 46.865313) + (xy 112.597194 46.69849) (xy 112.614281 46.525001) (xy 112.597194 46.35151) (xy 112.546588 46.184687) (xy 112.46441 46.030941) + (xy 112.353817 45.896183) (xy 112.219059 45.78559) (xy 112.065313 45.703412) (xy 111.89849 45.652806) (xy 111.730095 45.636221) + (xy 111.730095 44.71435) (xy 111.733771 44.677025) (xy 111.730095 44.6397) (xy 111.730095 44.639692) (xy 111.719098 44.528039) + (xy 111.675641 44.384778) (xy 111.605069 44.252749) (xy 111.510096 44.137024) (xy 111.481099 44.113227) (xy 110.085187 42.717315) + (xy 110.115815 42.563337) (xy 110.115815 42.288153) (xy 110.062129 42.018255) (xy 109.95682 41.764018) (xy 109.803935 41.53521) + (xy 109.60935 41.340625) (xy 109.380542 41.18774) (xy 109.126305 41.082431) (xy 108.856407 41.028745) (xy 108.804337 41.028745) + (xy 108.780719 40.910011) (xy 118.021298 40.910011) + ) + ) + (filled_polygon + (pts + (xy 123.027 62.598) (xy 123.047 62.598) (xy 123.047 62.852) (xy 123.027 62.852) (xy 123.027 62.872) + (xy 122.96 62.872) (xy 122.96 62.578) (xy 123.027 62.578) + ) + ) + (filled_polygon + (pts + (xy 121.074188 59.249482) (xy 121.110498 59.36918) (xy 121.169463 59.479494) (xy 121.186292 59.5) (xy 121.169463 59.520506) + (xy 121.110498 59.63082) (xy 121.074188 59.750518) (xy 121.061928 59.875) (xy 121.065 60.08925) (xy 121.22375 60.248) + (xy 122.573 60.248) (xy 122.573 60.228) (xy 122.827 60.228) (xy 122.827 60.248) (xy 124.17625 60.248) + (xy 124.192372 60.231878) (xy 124.204479 60.239967) (xy 124.35644 60.302911) (xy 124.51776 60.335) (xy 124.68224 60.335) + (xy 124.84356 60.302911) (xy 124.877316 60.288929) (xy 125.140001 60.551615) (xy 125.14 62.809132) (xy 125.132281 62.801413) + (xy 124.995521 62.710033) (xy 124.84356 62.647089) (xy 124.68224 62.615) (xy 124.51776 62.615) (xy 124.35644 62.647089) + (xy 124.335 62.65597) (xy 124.335 62.597998) (xy 124.176252 62.597998) (xy 124.335 62.43925) (xy 124.338072 62.225) + (xy 124.325812 62.100518) (xy 124.289502 61.98082) (xy 124.230537 61.870506) (xy 124.151185 61.773815) (xy 124.054494 61.694463) + (xy 123.94418 61.635498) (xy 123.824482 61.599188) (xy 123.7 61.586928) (xy 123.18575 61.59) (xy 123.027002 61.748748) + (xy 123.027002 61.59) (xy 122.96 61.59) (xy 122.96 61.48425) (xy 122.98575 61.51) (xy 123.7 61.513072) + (xy 123.824482 61.500812) (xy 123.94418 61.464502) (xy 124.054494 61.405537) (xy 124.151185 61.326185) (xy 124.230537 61.229494) + (xy 124.289502 61.11918) (xy 124.325812 60.999482) (xy 124.338072 60.875) (xy 124.335 60.66075) (xy 124.17625 60.502) + (xy 122.827 60.502) (xy 122.827 60.522) (xy 122.573 60.522) (xy 122.573 60.502) (xy 121.22375 60.502) + (xy 121.08575 60.64) (xy 119.938072 60.64) (xy 119.938072 60.376727) (xy 121.073393 59.241407) + ) + ) + (filled_polygon + (pts + (xy 170.540001 60.79358) (xy 170.540001 60.934983) (xy 170.505537 60.870506) (xy 170.426185 60.773815) (xy 170.329494 60.694463) + (xy 170.21918 60.635498) (xy 170.099482 60.599188) (xy 169.975 60.586928) (xy 169.025 60.586928) (xy 168.900518 60.599188) + (xy 168.78082 60.635498) (xy 168.670506 60.694463) (xy 168.654011 60.708) (xy 165.071576 60.708) (xy 167.762999 58.016578) + ) + ) + (filled_polygon + (pts + (xy 142.027 60.098) (xy 142.047 60.098) (xy 142.047 60.352) (xy 142.027 60.352) (xy 142.027 60.372) + (xy 141.96 60.372) (xy 141.96 60.078) (xy 142.027 60.078) + ) + ) + (filled_polygon + (pts + (xy 164.967125 57.081921) (xy 165.010036 57.185518) (xy 165.101416 57.322278) (xy 165.217722 57.438584) (xy 165.354482 57.529964) + (xy 165.506443 57.592908) (xy 165.654133 57.622286) (xy 163.27142 60.005) (xy 162.512202 60.005) (xy 162.536004 59.975997) + (xy 162.810998 59.701003) (xy 162.840001 59.677201) (xy 162.934974 59.561476) (xy 163.005546 59.429447) (xy 163.049003 59.286186) + (xy 163.06 59.174533) (xy 163.06 59.174524) (xy 163.063676 59.137201) (xy 163.06 59.099878) (xy 163.06 59.087157) + (xy 163.102911 58.98356) (xy 163.135 58.82224) (xy 163.135 58.65776) (xy 163.102911 58.49644) (xy 163.039967 58.344479) + (xy 162.948587 58.207719) (xy 162.832281 58.091413) (xy 162.695521 58.000033) (xy 162.54356 57.937089) (xy 162.38224 57.905) + (xy 162.33925 57.905) (xy 162.27625 57.842) (xy 161.127 57.842) (xy 161.127 57.862) (xy 161.06 57.862) + (xy 161.06 57.568) (xy 161.127 57.568) (xy 161.127 57.588) (xy 162.27625 57.588) (xy 162.435 57.42925) + (xy 162.438072 57.215) (xy 162.425812 57.090518) (xy 162.389502 56.97082) (xy 162.330537 56.860506) (xy 162.251185 56.763815) + (xy 162.154494 56.684463) (xy 162.04418 56.625498) (xy 161.924482 56.589188) (xy 161.8 56.576928) (xy 161.28575 56.58) + (xy 161.127002 56.738748) (xy 161.127002 56.58) (xy 161.06 56.58) (xy 161.06 56.365677) (xy 161.063435 56.3308) + (xy 161.049727 56.191616) (xy 161.009128 56.05778) (xy 160.9432 55.934437) (xy 160.854475 55.826325) (xy 160.826141 55.803072) + (xy 161.7 55.803072) (xy 161.824482 55.790812) (xy 161.94418 55.754502) (xy 162.054494 55.695537) (xy 162.151185 55.616185) + (xy 162.230537 55.519494) (xy 162.289502 55.40918) (xy 162.306939 55.351697) (xy 162.40644 55.392911) (xy 162.56776 55.425) + (xy 162.73224 55.425) (xy 162.89356 55.392911) (xy 162.997157 55.35) (xy 163.235205 55.35) + ) + ) + (filled_polygon + (pts + (xy 205.115 47.543476) (xy 205.115001 47.543486) (xy 205.115 53.401627) (xy 205.09418 53.390498) (xy 204.974482 53.354188) + (xy 204.85 53.341928) (xy 204.623127 53.341928) (xy 204.635 53.28224) (xy 204.635 53.11776) (xy 204.602911 52.95644) + (xy 204.539967 52.804479) (xy 204.448587 52.667719) (xy 204.332281 52.551413) (xy 204.195521 52.460033) (xy 204.04356 52.397089) + (xy 203.88224 52.365) (xy 203.71776 52.365) (xy 203.55644 52.397089) (xy 203.404479 52.460033) (xy 203.365 52.486412) + (xy 203.365 52.243891) (xy 203.304089 51.937673) (xy 203.184609 51.649221) (xy 203.01115 51.389621) (xy 202.790379 51.16885) + (xy 202.530779 50.995391) (xy 202.242327 50.875911) (xy 201.936109 50.815) (xy 201.623891 50.815) (xy 201.317673 50.875911) + (xy 201.223303 50.915) (xy 201.05374 50.915) (xy 200.766842 50.972068) (xy 200.76 50.974902) (xy 200.76 48.399322) + (xy 200.763676 48.361999) (xy 200.76 48.324676) (xy 200.76 48.324667) (xy 200.749863 48.221741) (xy 200.819001 48.165001) + (xy 200.842804 48.135997) (xy 201.260997 47.717804) (xy 201.290001 47.694001) (xy 201.384974 47.578276) (xy 201.409559 47.532281) + (xy 201.453438 47.45019) (xy 201.489967 47.395521) (xy 201.552911 47.24356) (xy 201.585 47.08224) (xy 201.585 46.91776) + (xy 201.552911 46.75644) (xy 201.489967 46.604479) (xy 201.398587 46.467719) (xy 201.282281 46.351413) (xy 201.145521 46.260033) + (xy 200.99356 46.197089) (xy 200.83224 46.165) (xy 200.66776 46.165) (xy 200.50644 46.197089) (xy 200.446264 46.222014) + (xy 200.37625 46.152) (xy 199.227 46.152) (xy 199.227 46.172) (xy 199.16 46.172) (xy 199.16 45.878) + (xy 199.227 45.878) (xy 199.227 45.898) (xy 200.37625 45.898) (xy 200.535 45.73925) (xy 200.538072 45.525) + (xy 200.525812 45.400518) (xy 200.489502 45.28082) (xy 200.430537 45.170506) (xy 200.351185 45.073815) (xy 200.254494 44.994463) + (xy 200.14418 44.935498) (xy 200.024482 44.899188) (xy 199.9 44.886928) (xy 199.38575 44.89) (xy 199.227002 45.048748) + (xy 199.227002 44.89) (xy 199.16 44.89) (xy 199.16 44.684877) (xy 199.163435 44.65) (xy 199.149727 44.510816) + (xy 199.109128 44.37698) (xy 199.092783 44.3464) (xy 205.115001 44.3464) + ) + ) + (filled_polygon + (pts + (xy 166.865001 52.905) (xy 165.682887 52.905) (xy 165.782281 52.838587) (xy 165.898587 52.722281) (xy 165.989967 52.585521) + (xy 166.052911 52.43356) (xy 166.085 52.27224) (xy 166.085 52.10776) (xy 166.052911 51.94644) (xy 166.01 51.842843) + (xy 166.01 49.218072) (xy 166.75 49.218072) (xy 166.865001 49.206746) + ) + ) + (filled_polygon + (pts + (xy 199.240001 51.51586) (xy 199.079417 51.128175) (xy 198.785576 50.688412) (xy 198.411588 50.314424) (xy 197.971825 50.020583) + (xy 197.584142 49.86) (xy 198.415123 49.86) (xy 198.45 49.863435) (xy 198.484877 49.86) (xy 198.589184 49.849727) + (xy 198.72302 49.809128) (xy 198.846363 49.7432) (xy 198.954475 49.654475) (xy 199.0432 49.546363) (xy 199.109128 49.42302) + (xy 199.149727 49.289184) (xy 199.163435 49.15) (xy 199.16 49.115123) (xy 199.16 48.913072) (xy 199.24 48.913072) + ) + ) + (filled_polygon + (pts + (xy 210.464999 47.30653) (xy 210.460718 47.349999) (xy 210.464999 47.393468) (xy 210.464999 47.393475) (xy 210.475589 47.500997) + (xy 210.477804 47.523489) (xy 210.490032 47.563799) (xy 210.52841 47.690311) (xy 210.610588 47.844057) (xy 210.721182 47.978816) + (xy 210.754955 48.006533) (xy 211.118466 48.370044) (xy 211.146183 48.403817) (xy 211.280941 48.514411) (xy 211.434687 48.596589) + (xy 211.60151 48.647195) (xy 211.731523 48.66) (xy 211.731533 48.66) (xy 211.774999 48.664281) (xy 211.818465 48.66) + (xy 212.037036 48.66) (xy 211.997089 48.75644) (xy 211.965 48.91776) (xy 211.965 49.08224) (xy 211.997089 49.24356) + (xy 212.040001 49.347159) (xy 212.04 50.452843) (xy 211.997089 50.55644) (xy 211.965 50.71776) (xy 211.965 50.88224) + (xy 211.997089 51.04356) (xy 212.017836 51.093649) (xy 212.003411 51.08401) (xy 211.733158 50.972068) (xy 211.44626 50.915) + (xy 211.276697 50.915) (xy 211.182327 50.875911) (xy 210.876109 50.815) (xy 210.563891 50.815) (xy 210.257673 50.875911) + (xy 210.01 50.9785) (xy 210.01 47.009587) (xy 210.04356 47.002911) (xy 210.195521 46.939967) (xy 210.332281 46.848587) + (xy 210.448587 46.732281) (xy 210.464999 46.707719) + ) + ) + (filled_polygon + (pts + (xy 123.09 49.240848) (xy 123.087945 49.247622) (xy 123.081817 49.216814) (xy 122.879417 48.728175) (xy 122.585576 48.288412) + (xy 122.211588 47.914424) (xy 121.771825 47.620583) (xy 121.384142 47.46) (xy 122.215123 47.46) (xy 122.25 47.463435) + (xy 122.284877 47.46) (xy 122.389184 47.449727) (xy 122.52302 47.409128) (xy 122.646363 47.3432) (xy 122.754475 47.254475) + (xy 122.8432 47.146363) (xy 122.909128 47.02302) (xy 122.949727 46.889184) (xy 122.963435 46.75) (xy 122.96 46.715123) + (xy 122.96 46.513072) (xy 123.090001 46.513072) + ) + ) + (filled_polygon + (pts + (xy 110.210095 44.991827) (xy 110.210095 47.114649) (xy 110.076509 47.127806) (xy 110.068438 47.130254) (xy 109.986451 46.902722) + (xy 109.924471 46.786765) (xy 109.68438 46.719785) (xy 108.89842 47.505745) (xy 108.912563 47.519888) (xy 108.732958 47.699493) + (xy 108.718815 47.68535) (xy 108.704673 47.699493) (xy 108.525068 47.519888) (xy 108.53921 47.505745) (xy 108.525068 47.491603) + (xy 108.704673 47.311998) (xy 108.718815 47.32614) (xy 109.504775 46.54018) (xy 109.437795 46.300089) (xy 109.302055 46.23626) + (xy 109.380542 46.20375) (xy 109.60935 46.050865) (xy 109.803935 45.85628) (xy 109.95682 45.627472) (xy 110.062129 45.373235) + (xy 110.115815 45.103337) (xy 110.115815 44.897547) + ) + ) + (filled_polygon + (pts + (xy 166.68524 43.373311) (xy 166.84656 43.4054) (xy 166.865 43.4054) (xy 166.865 45.953254) (xy 166.75 45.941928) + (xy 164.956887 45.941928) (xy 165.084609 45.750779) (xy 165.204089 45.462327) (xy 165.265 45.156109) (xy 165.265 44.843891) + (xy 165.204089 44.537673) (xy 165.084609 44.249221) (xy 164.91115 43.989621) (xy 164.690379 43.76885) (xy 164.430779 43.595391) + (xy 164.142327 43.475911) (xy 163.836109 43.415) (xy 163.523891 43.415) (xy 163.217673 43.475911) (xy 163.123303 43.515) + (xy 162.95374 43.515) (xy 162.666842 43.572068) (xy 162.66 43.574902) (xy 162.66 43.4308) (xy 162.71844 43.4308) + (xy 162.87976 43.398711) (xy 162.983357 43.3558) (xy 166.642965 43.3558) + ) + ) + (filled_polygon + (pts + (xy 153.945628 40.970049) (xy 153.973341 41.003817) (xy 154.007109 41.03153) (xy 154.007111 41.031532) (xy 154.08378 41.094453) + (xy 154.108099 41.114411) (xy 154.261845 41.196589) (xy 154.428668 41.247195) (xy 154.558681 41.26) (xy 154.558689 41.26) + (xy 154.602158 41.264281) (xy 154.645627 41.26) (xy 154.894499 41.26) (xy 154.948815 41.326185) (xy 155.045506 41.405537) + (xy 155.15582 41.464502) (xy 155.275518 41.500812) (xy 155.4 41.513072) (xy 156.14 41.513072) (xy 156.14 41.695923) + (xy 156.136565 41.7308) (xy 156.150273 41.869984) (xy 156.190872 42.00382) (xy 156.2568 42.127163) (xy 156.345525 42.235275) + (xy 156.442702 42.315026) (xy 156.453637 42.324) (xy 156.57698 42.389928) (xy 156.710816 42.430527) (xy 156.85 42.444235) + (xy 156.884877 42.4408) (xy 157.762211 42.4408) (xy 157.328175 42.620583) (xy 156.888412 42.914424) (xy 156.514424 43.288412) + (xy 156.220583 43.728175) (xy 156.018183 44.216814) (xy 155.915 44.735551) (xy 155.915 45.264449) (xy 156.018183 45.783186) + (xy 156.023749 45.796623) (xy 155.801302 45.647989) (xy 155.492012 45.519877) (xy 155.527932 45.433158) (xy 155.585 45.14626) + (xy 155.585 44.85374) (xy 155.527932 44.566842) (xy 155.41599 44.296589) (xy 155.253475 44.053368) (xy 155.046632 43.846525) + (xy 154.803411 43.68401) (xy 154.533158 43.572068) (xy 154.24626 43.515) (xy 154.076697 43.515) (xy 153.982327 43.475911) + (xy 153.676109 43.415) (xy 153.363891 43.415) (xy 153.057673 43.475911) (xy 152.769221 43.595391) (xy 152.75998 43.601566) + (xy 152.75998 42.090953) (xy 152.810242 42.015731) (xy 152.873186 41.86377) (xy 152.905275 41.70245) (xy 152.905275 41.53797) + (xy 152.873186 41.37665) (xy 152.810242 41.224689) (xy 152.718862 41.087929) (xy 152.602556 40.971623) (xy 152.465796 40.880243) + (xy 152.313835 40.817299) (xy 152.152515 40.78521) (xy 151.988035 40.78521) (xy 151.826715 40.817299) (xy 151.674754 40.880243) + (xy 151.613072 40.921458) (xy 151.613072 40.615) (xy 151.609329 40.576992) (xy 151.666178 40.614977) (xy 151.818139 40.677921) + (xy 151.979459 40.71001) (xy 152.143939 40.71001) (xy 152.305259 40.677921) (xy 152.45722 40.614977) (xy 152.473316 40.604222) + (xy 152.479614 40.606831) (xy 152.640934 40.63892) (xy 152.805414 40.63892) (xy 152.966734 40.606831) (xy 153.118695 40.543887) + (xy 153.255455 40.452507) (xy 153.341771 40.366191) + ) + ) + (filled_polygon + (pts + (xy 131.359627 42.717428) (xy 130.525 42.717428) (xy 130.400518 42.729688) (xy 130.28082 42.765998) (xy 130.170506 42.824963) + (xy 130.073815 42.904315) (xy 129.994463 43.001006) (xy 129.960257 43.065) (xy 129.91776 43.065) (xy 129.804704 43.087489) + (xy 129.755537 42.995506) (xy 129.676185 42.898815) (xy 129.579494 42.819463) (xy 129.46918 42.760498) (xy 129.349482 42.724188) + (xy 129.225 42.711928) (xy 128.275 42.711928) (xy 128.150518 42.724188) (xy 128.03082 42.760498) (xy 127.920506 42.819463) + (xy 127.823815 42.898815) (xy 127.744463 42.995506) (xy 127.685498 43.10582) (xy 127.652379 43.215) (xy 127.412322 43.215) + (xy 127.374999 43.211324) (xy 127.337676 43.215) (xy 127.337667 43.215) (xy 127.226014 43.225997) (xy 127.082753 43.269454) + (xy 126.950724 43.340026) (xy 126.944903 43.344803) (xy 126.863996 43.411201) (xy 126.863992 43.411205) (xy 126.834999 43.434999) + (xy 126.811205 43.463992) (xy 126.458076 43.817122) (xy 126.354479 43.860033) (xy 126.217719 43.951413) (xy 126.211841 43.957291) + (xy 126.189967 43.904481) (xy 126.098587 43.767721) (xy 125.982281 43.651415) (xy 125.845521 43.560035) (xy 125.69356 43.497091) + (xy 125.53224 43.465002) (xy 125.36776 43.465002) (xy 125.20644 43.497091) (xy 125.054479 43.560035) (xy 124.917719 43.651415) + (xy 124.801413 43.767721) (xy 124.710033 43.904481) (xy 124.667122 44.008079) (xy 124.270533 44.404667) (xy 124.289502 44.36918) + (xy 124.325812 44.249482) (xy 124.338072 44.125) (xy 124.335 43.91075) (xy 124.17625 43.752) (xy 123.027 43.752) + (xy 123.027 43.772) (xy 122.96 43.772) (xy 122.96 43.478) (xy 123.027 43.478) (xy 123.027 43.498) + (xy 124.17625 43.498) (xy 124.335 43.33925) (xy 124.338072 43.125) (xy 124.325812 43.000518) (xy 124.289502 42.88082) + (xy 124.230537 42.770506) (xy 124.151185 42.673815) (xy 124.054494 42.594463) (xy 123.94418 42.535498) (xy 123.824482 42.499188) + (xy 123.7 42.486928) (xy 123.18575 42.49) (xy 123.027002 42.648748) (xy 123.027002 42.49) (xy 122.96 42.49) + (xy 122.96 42.41) (xy 131.052199 42.41) + ) + ) + (filled_polygon + (pts + (xy 161.14 44.115859) (xy 160.979417 43.728175) (xy 160.685576 43.288412) (xy 160.311588 42.914424) (xy 159.871825 42.620583) + (xy 159.437789 42.4408) (xy 160.315123 42.4408) (xy 160.35 42.444235) (xy 160.384877 42.4408) (xy 160.398006 42.439507) + (xy 160.489184 42.430527) (xy 160.62302 42.389928) (xy 160.746363 42.324) (xy 160.854475 42.235275) (xy 160.9432 42.127163) + (xy 161.009128 42.00382) (xy 161.049727 41.869984) (xy 161.058097 41.785) (xy 161.063435 41.7308) (xy 161.06 41.695923) + (xy 161.06 41.513072) (xy 161.140001 41.513072) + ) + ) + (filled_polygon + (pts + (xy 107.613748 43.755858) (xy 107.599605 43.77) (xy 107.613748 43.784143) (xy 107.434143 43.963748) (xy 107.42 43.949605) + (xy 107.405858 43.963748) (xy 107.226253 43.784143) (xy 107.240395 43.77) (xy 107.226253 43.755858) (xy 107.405858 43.576253) + (xy 107.42 43.590395) (xy 107.434143 43.576253) + ) + ) + (filled_polygon + (pts + (xy 167.409687 37.618411) (xy 167.255941 37.700589) (xy 167.121183 37.811183) (xy 167.010589 37.945942) (xy 166.928411 38.099688) + (xy 166.877805 38.266511) (xy 166.865 38.396524) (xy 166.865 41.7354) (xy 166.84656 41.7354) (xy 166.68524 41.767489) + (xy 166.533279 41.830433) (xy 166.525247 41.8358) (xy 162.983357 41.8358) (xy 162.87976 41.792889) (xy 162.71844 41.7608) + (xy 162.66 41.7608) (xy 162.66 40.969822) (xy 162.663676 40.932499) (xy 162.66 40.895176) (xy 162.66 40.895167) + (xy 162.649003 40.783514) (xy 162.605546 40.640253) (xy 162.600108 40.630079) (xy 162.560191 40.5554) (xy 162.563804 40.550997) + (xy 162.791911 40.32289) (xy 162.895537 40.279967) (xy 163.032297 40.188587) (xy 163.148603 40.072281) (xy 163.239983 39.935521) + (xy 163.302927 39.78356) (xy 163.335016 39.62224) (xy 163.335016 39.45776) (xy 163.302927 39.29644) (xy 163.239983 39.144479) + (xy 163.148603 39.007719) (xy 163.032297 38.891413) (xy 162.895537 38.800033) (xy 162.743576 38.737089) (xy 162.582256 38.705) + (xy 162.417776 38.705) (xy 162.256456 38.737089) (xy 162.220457 38.752) (xy 161.127 38.752) (xy 161.127 38.772) + (xy 161.06 38.772) (xy 161.06 38.478) (xy 161.127 38.478) (xy 161.127 38.498) (xy 162.27625 38.498) + (xy 162.435 38.33925) (xy 162.438072 38.125) (xy 162.425812 38.000518) (xy 162.389502 37.88082) (xy 162.330537 37.770506) + (xy 162.251185 37.673815) (xy 162.154494 37.594463) (xy 162.147622 37.59079) (xy 167.50074 37.59079) + ) + ) + (filled_polygon + (pts + (xy 142.027 40.998) (xy 142.047 40.998) (xy 142.047 41.252) (xy 142.027 41.252) (xy 142.027 41.272) + (xy 141.96 41.272) (xy 141.96 40.978) (xy 142.027 40.978) + ) + ) + (filled_polygon + (pts + (xy 182.019511 37.44) (xy 172.042602 37.44) (xy 170.472384 35.869783) (xy 170.448581 35.840779) (xy 170.332856 35.745806) + (xy 170.219098 35.685) (xy 170.896299 35.685) + ) + ) + (filled_polygon + (pts + (xy 153.944944 35.745806) (xy 153.944942 35.745807) (xy 153.944943 35.745807) (xy 153.858216 35.816981) (xy 153.858212 35.816985) + (xy 153.829219 35.840779) (xy 153.805425 35.869772) (xy 152.685199 36.99) (xy 152.266679 36.99) (xy 152.229356 36.986324) + (xy 152.192034 36.99) (xy 152.192023 36.99) (xy 152.08037 37.000997) (xy 152.068235 37.004678) (xy 115.204767 37.004678) + (xy 149.013379 35.685) (xy 154.058702 35.685) + ) + ) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak new file mode 100644 index 00000000..200eaf3f --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak @@ -0,0 +1,16436 @@ +(kicad_pcb (version 20171130) (host pcbnew "(5.1.12-1-10_14)") + + (general + (thickness 1.6) + (drawings 350) + (tracks 3564) + (zones 0) + (modules 96) + (nets 95) + ) + + (page A4) + (layers + (0 F.Cu signal) + (31 B.Cu signal) + (32 B.Adhes user hide) + (33 F.Adhes user hide) + (34 B.Paste user) + (35 F.Paste user) + (36 B.SilkS user) + (37 F.SilkS user) + (38 B.Mask user) + (39 F.Mask user) + (40 Dwgs.User user hide) + (41 Cmts.User user hide) + (42 Eco1.User user hide) + (43 Eco2.User user hide) + (44 Edge.Cuts user) + (45 Margin user hide) + (46 B.CrtYd user hide) + (47 F.CrtYd user hide) + (48 B.Fab user hide) + (49 F.Fab user hide) + ) + + (setup + (last_trace_width 0.25) + (user_trace_width 0.25) + (user_trace_width 0.5) + (trace_clearance 0.2) + (zone_clearance 0.5) + (zone_45_only no) + (trace_min 0.2) + (via_size 0.4) + (via_drill 0.3) + (via_min_size 0.4) + (via_min_drill 0.3) + (uvia_size 0.3) + (uvia_drill 0.1) + (uvias_allowed no) + (uvia_min_size 0.2) + (uvia_min_drill 0.1) + (edge_width 0.15) + (segment_width 0.2) + (pcb_text_width 0.3) + (pcb_text_size 1.5 1.5) + (mod_edge_width 0.15) + (mod_text_size 1 1) + (mod_text_width 0.15) + (pad_size 0.635 1.143) + (pad_drill 0) + (pad_to_mask_clearance 0.2) + (aux_axis_origin 0 0) + (visible_elements 7FFFF7FF) + (pcbplotparams + (layerselection 0x010f0_ffffffff) + (usegerberextensions true) + (usegerberattributes false) + (usegerberadvancedattributes false) + (creategerberjobfile false) + (excludeedgelayer true) + (linewidth 0.100000) + (plotframeref false) + (viasonmask false) + (mode 1) + (useauxorigin false) + (hpglpennumber 1) + (hpglpenspeed 20) + (hpglpendiameter 15.000000) + (psnegative false) + (psa4output false) + (plotreference true) + (plotvalue true) + (plotinvisibletext false) + (padsonsilk false) + (subtractmaskfromsilk false) + (outputformat 1) + (mirror false) + (drillshape 0) + (scaleselection 1) + (outputdirectory "gerber/")) + ) + + (net 0 "") + (net 1 "Net-(D1-Pad2)") + (net 2 row4) + (net 3 "Net-(D2-Pad2)") + (net 4 "Net-(D3-Pad2)") + (net 5 row0) + (net 6 "Net-(D4-Pad2)") + (net 7 row1) + (net 8 "Net-(D5-Pad2)") + (net 9 row2) + (net 10 "Net-(D6-Pad2)") + (net 11 row3) + (net 12 "Net-(D7-Pad2)") + (net 13 "Net-(D8-Pad2)") + (net 14 "Net-(D9-Pad2)") + (net 15 "Net-(D10-Pad2)") + (net 16 "Net-(D11-Pad2)") + (net 17 "Net-(D12-Pad2)") + (net 18 "Net-(D13-Pad2)") + (net 19 "Net-(D14-Pad2)") + (net 20 "Net-(D15-Pad2)") + (net 21 "Net-(D16-Pad2)") + (net 22 "Net-(D17-Pad2)") + (net 23 "Net-(D18-Pad2)") + (net 24 "Net-(D19-Pad2)") + (net 25 "Net-(D20-Pad2)") + (net 26 "Net-(D21-Pad2)") + (net 27 "Net-(D22-Pad2)") + (net 28 "Net-(D23-Pad2)") + (net 29 "Net-(D24-Pad2)") + (net 30 "Net-(D26-Pad2)") + (net 31 "Net-(D27-Pad2)") + (net 32 "Net-(D28-Pad2)") + (net 33 VCC) + (net 34 GND) + (net 35 col0) + (net 36 col1) + (net 37 col2) + (net 38 col3) + (net 39 col4) + (net 40 SDA) + (net 41 LED) + (net 42 SCL) + (net 43 RESET) + (net 44 "Net-(D29-Pad2)") + (net 45 "Net-(U1-Pad24)") + (net 46 "Net-(U1-Pad7)") + (net 47 DATA) + (net 48 "Net-(J3-Pad1)") + (net 49 "Net-(J3-Pad2)") + (net 50 "Net-(J3-Pad3)") + (net 51 "Net-(J3-Pad4)") + (net 52 "Net-(D30-Pad2)") + (net 53 SW25B) + (net 54 SW25A) + (net 55 ENCB) + (net 56 ENCA) + (net 57 /i2c_c) + (net 58 /i2c_d) + (net 59 "Net-(D31-Pad1)") + (net 60 "Net-(D31-Pad3)") + (net 61 "Net-(D32-Pad3)") + (net 62 "Net-(D34-Pad1)") + (net 63 "Net-(D35-Pad1)") + (net 64 lights) + (net 65 "Net-(SW1-Pad3)") + (net 66 "Net-(SW1-Pad1)") + (net 67 "Net-(SW2-Pad3)") + (net 68 "Net-(SW3-Pad3)") + (net 69 "Net-(SW3-Pad1)") + (net 70 "Net-(SW10-Pad1)") + (net 71 "Net-(SW5-Pad3)") + (net 72 "Net-(SW11-Pad3)") + (net 73 "Net-(SW12-Pad1)") + (net 74 "Net-(SW13-Pad3)") + (net 75 "Net-(SW14-Pad1)") + (net 76 "Net-(SW15-Pad3)") + (net 77 "Net-(SW10-Pad3)") + (net 78 "Net-(SW11-Pad1)") + (net 79 "Net-(SW12-Pad3)") + (net 80 "Net-(SW13-Pad1)") + (net 81 "Net-(SW14-Pad3)") + (net 82 "Net-(SW15-Pad1)") + (net 83 "Net-(SW16-Pad3)") + (net 84 "Net-(SW17-Pad1)") + (net 85 "Net-(SW18-Pad3)") + (net 86 "Net-(SW19-Pad1)") + (net 87 "Net-(SW20-Pad3)") + (net 88 "Net-(SW21-Pad1)") + (net 89 "Net-(SW22-Pad3)") + (net 90 "Net-(SW23-Pad1)") + (net 91 "Net-(SW24-Pad3)") + (net 92 "Net-(SW26-Pad3)") + (net 93 "Net-(SW28-Pad3)") + (net 94 BL) + + (net_class Default "これは標準のネット クラスです。" + (clearance 0.2) + (trace_width 0.25) + (via_dia 0.4) + (via_drill 0.3) + (uvia_dia 0.3) + (uvia_drill 0.1) + (add_net /i2c_c) + (add_net /i2c_d) + (add_net BL) + (add_net DATA) + (add_net ENCA) + (add_net ENCB) + (add_net LED) + (add_net "Net-(D1-Pad2)") + (add_net "Net-(D10-Pad2)") + (add_net "Net-(D11-Pad2)") + (add_net "Net-(D12-Pad2)") + (add_net "Net-(D13-Pad2)") + (add_net "Net-(D14-Pad2)") + (add_net "Net-(D15-Pad2)") + (add_net "Net-(D16-Pad2)") + (add_net "Net-(D17-Pad2)") + (add_net "Net-(D18-Pad2)") + (add_net "Net-(D19-Pad2)") + (add_net "Net-(D2-Pad2)") + (add_net "Net-(D20-Pad2)") + (add_net "Net-(D21-Pad2)") + (add_net "Net-(D22-Pad2)") + (add_net "Net-(D23-Pad2)") + (add_net "Net-(D24-Pad2)") + (add_net "Net-(D26-Pad2)") + (add_net "Net-(D27-Pad2)") + (add_net "Net-(D28-Pad2)") + (add_net "Net-(D29-Pad2)") + (add_net "Net-(D3-Pad2)") + (add_net "Net-(D30-Pad2)") + (add_net "Net-(D31-Pad1)") + (add_net "Net-(D31-Pad3)") + (add_net "Net-(D32-Pad3)") + (add_net "Net-(D34-Pad1)") + (add_net "Net-(D35-Pad1)") + (add_net "Net-(D4-Pad2)") + (add_net "Net-(D5-Pad2)") + (add_net "Net-(D6-Pad2)") + (add_net "Net-(D7-Pad2)") + (add_net "Net-(D8-Pad2)") + (add_net "Net-(D9-Pad2)") + (add_net "Net-(J3-Pad1)") + (add_net "Net-(J3-Pad2)") + (add_net "Net-(J3-Pad3)") + (add_net "Net-(J3-Pad4)") + (add_net "Net-(SW1-Pad1)") + (add_net "Net-(SW1-Pad3)") + (add_net "Net-(SW10-Pad1)") + (add_net "Net-(SW10-Pad3)") + (add_net "Net-(SW11-Pad1)") + (add_net "Net-(SW11-Pad3)") + (add_net "Net-(SW12-Pad1)") + (add_net "Net-(SW12-Pad3)") + (add_net "Net-(SW13-Pad1)") + (add_net "Net-(SW13-Pad3)") + (add_net "Net-(SW14-Pad1)") + (add_net "Net-(SW14-Pad3)") + (add_net "Net-(SW15-Pad1)") + (add_net "Net-(SW15-Pad3)") + (add_net "Net-(SW16-Pad3)") + (add_net "Net-(SW17-Pad1)") + (add_net "Net-(SW18-Pad3)") + (add_net "Net-(SW19-Pad1)") + (add_net "Net-(SW2-Pad3)") + (add_net "Net-(SW20-Pad3)") + (add_net "Net-(SW21-Pad1)") + (add_net "Net-(SW22-Pad3)") + (add_net "Net-(SW23-Pad1)") + (add_net "Net-(SW24-Pad3)") + (add_net "Net-(SW26-Pad3)") + (add_net "Net-(SW28-Pad3)") + (add_net "Net-(SW3-Pad1)") + (add_net "Net-(SW3-Pad3)") + (add_net "Net-(SW5-Pad3)") + (add_net "Net-(U1-Pad24)") + (add_net "Net-(U1-Pad7)") + (add_net RESET) + (add_net SCL) + (add_net SDA) + (add_net SW25A) + (add_net SW25B) + (add_net col0) + (add_net col1) + (add_net col2) + (add_net col3) + (add_net col4) + (add_net lights) + (add_net row0) + (add_net row1) + (add_net row2) + (add_net row3) + (add_net row4) + ) + + (net_class GND "" + (clearance 0.2) + (trace_width 0.5) + (via_dia 0.4) + (via_drill 0.3) + (uvia_dia 0.3) + (uvia_drill 0.1) + (add_net GND) + ) + + (net_class VCC "" + (clearance 0.2) + (trace_width 0.5) + (via_dia 0.4) + (via_drill 0.3) + (uvia_dia 0.3) + (uvia_drill 0.1) + (add_net VCC) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FD12) (tstamp 61CC20B4) + (at 185.4454 99.3394 270) + (path /5B911E74) + (attr smd) + (fp_text reference JP9 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 94 BL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 64 lights) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9E1) + (at 108.85 124.13) + (path /5F7EC8B3) + (fp_text reference D34 (at 0.95 -0.735) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C999) + (at 120.5 59.5 180) + (path /5F7E6561) + (fp_text reference D31 (at -4.94 -0.76) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9B1) + (at 158.5 53.79) + (path /5F7E9258) + (fp_text reference D32 (at -5.21 -1.04) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9C9) + (at 197.5 61.25 180) + (path /5F7EC8AD) + (fp_text reference D33 (at -4.84 1.41) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 64 lights)) + (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 64 lights)) + (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9F9) + (at 149.0836 118.2626) + (path /5F7EF5F2) + (fp_text reference D35 (at 0.88 -0.76) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA11) + (at 185.05 120.32) + (path /5F7EF5F8) + (fp_text reference D36 (at 0.87 -0.62) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA29) + (at 105.75 86.5) + (path /5F918D28) + (fp_text reference D37 (at 0 -2.5) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 41 LED)) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 64 lights)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 41 LED)) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 64 lights)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9874A) + (at 215.7 90.5 180) + (path /5F7D0195) + (fp_text reference SW18 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 23 "Net-(D18-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 23 "Net-(D18-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988EE) + (at 215.75 109.5 180) + (path /5F7D0171) + (fp_text reference SW24 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 29 "Net-(D24-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 29 "Net-(D24-Pad2)")) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FB9E) (tstamp 61CA7193) + (at 112.522 82.804 90) + (path /5B911E74) + (attr smd) + (fp_text reference JP9 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 41 LED) (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 64 lights) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988A8) + (at 196.7 109.5 180) + (path /5F7D0177) + (fp_text reference SW23 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 180) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 28 "Net-(D23-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 28 "Net-(D23-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5FB24B70) + (at 215.8 52.4 180) + (path /5B722CA9) + (fp_text reference SW6 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 10 "Net-(D6-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 10 "Net-(D6-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9881C) + (at 158.6 102.19 180) + (path /5F7D0183) + (fp_text reference SW21 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 26 "Net-(D21-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 26 "Net-(D21-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985A6) + (at 215.7 71.3 180) + (path /5B723AD3) + (fp_text reference SW12 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 17 "Net-(D12-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 17 "Net-(D12-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98560) + (at 196.7 71.3 180) + (path /5B72387D) + (fp_text reference SW11 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 16 "Net-(D11-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 16 "Net-(D11-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98704) + (at 196.7 90.5 180) + (path /5F7D019B) + (fp_text reference SW17 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 22 "Net-(D17-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 22 "Net-(D17-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982EA) + (at 139.5 47.5 180) + (path /5F74DC46) + (fp_text reference SW2 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 3 "Net-(D2-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 3 "Net-(D2-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F7EF4F0) + (at 177.6 123.8 180) + (path /5F7D72C1) + (fp_text reference SW30 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A4C) + (at 158.6 121.29 180) + (path /5F7D72A9) + (fp_text reference SW29 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A06) + (at 139.5 123.7 180) + (path /5F7D72AF) + (fp_text reference SW28 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F806503) + (at 117.6 128.4 195) + (path /5F7D72B5) + (fp_text reference SW27 (at 0 3 15 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.199999 15) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 15) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 15) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 285) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 15) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 31 "Net-(D27-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 15) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 31 "Net-(D27-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9897A) + (at 96.71 133.4 120) + (path /5F7D72BB) + (fp_text reference SW26 (at 0 3 300 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 120) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 210) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 300) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 30 "Net-(D26-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 300) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 30 "Net-(D26-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98862) + (at 177.6 104.7 180) + (path /5F7D017D) + (fp_text reference SW22 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 27 "Net-(D22-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 27 "Net-(D22-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE987D6) + (at 139.5 104.7 180) + (path /5F7D0189) + (fp_text reference SW20 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 25 "Net-(D20-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 25 "Net-(D20-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98790) + (at 120.5 107.1 180) + (path /5F7D018F) + (fp_text reference SW19 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE986BE) + (at 177.6 85.6 180) + (path /5F7D01A1) + (fp_text reference SW16 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 21 "Net-(D16-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 21 "Net-(D16-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98678) + (at 158.6 83.19 180) + (path /5F7D01A7) + (fp_text reference SW15 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 20 "Net-(D15-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 20 "Net-(D15-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98632) + (at 139.5 85.6 180) + (path /5F7D01AD) + (fp_text reference SW14 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_text user SW15 (at 7.1 8.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 19 "Net-(D14-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 19 "Net-(D14-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985EC) + (at 120.5 88.1 180) + (path /5F7D01B3) + (fp_text reference SW13 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9851A) + (at 177.6 66.5 180) + (path /5B7237A6) + (fp_text reference SW10 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 15 "Net-(D10-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 15 "Net-(D10-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE984D4) + (at 158.6 64.09 180) + (path /5B723731) + (fp_text reference SW9 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 14 "Net-(D9-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 14 "Net-(D9-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9848E) + (at 139.5 66.6 180) + (path /5B723388) + (fp_text reference SW8 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 13 "Net-(D8-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 13 "Net-(D8-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98448) + (at 120.5 69.1 180) + (path /5B723C9D) + (fp_text reference SW7 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE983BC) + (at 196.7 52.4 180) + (path /5B722B51) + (fp_text reference SW5 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 8 "Net-(D5-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 8 "Net-(D5-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98376) + (at 177.6 47.5 180) + (path /5F74FBCC) + (fp_text reference SW4 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 6 "Net-(D4-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 6 "Net-(D4-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98330) + (at 158.6 45 180) + (path /5F74EA54) + (fp_text reference SW3 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 4 "Net-(D3-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 4 "Net-(D3-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982A4) + (at 120.5 50 180) + (path /5B7225DA) + (fp_text reference SW1 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 1 "Net-(D1-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 1 "Net-(D1-Pad2)")) + ) + + (module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5FDCA436) (tstamp 5BEDDC08) + (at 107.9 81.1 180) + (path /5B74AE32) + (fp_text reference J1 (at 0 6.9 180) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED (at 0 7.62 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_text user GND (at -2.1836 5.0524 180) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user LED (at -2.2 2.5 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user GND (at -2.1836 5.0524 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user VCC (at -2.2 0.1 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user J1 (at 0 6.9 180) (layer B.SilkS) + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole rect (at 0 0 270) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 33 VCC)) + (pad 2 thru_hole rect (at 0 2.5 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 41 LED)) + (pad 3 thru_hole rect (at 0 5.1 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 34 GND)) + ) + + (module dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F8097A2) + (at 201 122.75 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + ) + (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) + (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) + (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) + (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) + (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) + (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) + (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) + (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) + (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) + (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) + (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) + (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) + (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) + (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) + (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) + (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) + (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) + (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) + (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) + (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) + (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) + (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) + (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) + (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) + (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) + (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) + (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) + (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) + (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) + (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) + (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) + (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) + (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) + (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) + (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) + (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) + (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) + (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) + (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) + (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) + (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) + (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) + (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) + (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) + (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) + (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) + (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) + (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) + (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) + (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) + (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) + (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) + (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) + (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) + (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) + (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) + (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) + (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) + (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) + (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) + (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) + (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) + (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) + (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) + (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) + (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) + (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) + (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) + (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) + (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) + (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) + (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) + (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) + (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) + (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) + (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) + (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) + (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) + (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) + (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) + (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) + (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) + (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) + (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) + (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) + (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) + (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) + (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) + (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) + (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) + (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) + (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) + (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) + (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) + (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) + (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) + (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) + (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) + (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) + (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) + (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) + (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) + (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) + (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) + (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) + (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) + (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) + (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) + (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) + (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) + (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) + (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) + (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) + (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) + (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) + (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) + (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) + (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) + (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) + (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) + (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) + (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) + (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) + (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) + (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) + (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) + (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) + (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) + (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) + (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) + (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) + (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) + (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) + (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) + (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) + (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) + (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) + (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) + (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) + (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) + (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) + (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) + (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) + (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) + (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) + (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) + (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) + (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) + (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) + (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) + (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) + (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) + ) + + (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F809028) + (at 200.25 122.75) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5D8B2928) + (at 125.805 119.02) + (descr "Resitance 3 pas") + (tags R) + (path /5D956FE1) + (autoplace_cost180 10) + (fp_text reference D30 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973B9) + (at 125.775 121.6) + (descr "Resitance 3 pas") + (tags R) + (path /5B734F9E) + (autoplace_cost180 10) + (fp_text reference D29 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973AC) + (at 125.775 124.2) + (descr "Resitance 3 pas") + (tags R) + (path /5B734CF9) + (autoplace_cost180 10) + (fp_text reference D28 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9739F) + (at 110.4248 120.6248) + (descr "Resitance 3 pas") + (tags R) + (path /5B734B62) + (autoplace_cost180 10) + (fp_text reference D27 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 31 "Net-(D27-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 31 "Net-(D27-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F7EDC95) (tstamp 5BE97392) + (at 100.8 123.6) + (descr "Resitance 3 pas") + (tags R) + (path /5B7349D1) + (autoplace_cost180 10) + (fp_text reference D26 (at 0.7222 -1.1752) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 30 "Net-(D26-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 30 "Net-(D26-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97385) + (at 107 97) + (descr "Resitance 3 pas") + (tags R) + (path /5B734844) + (autoplace_cost180 10) + (fp_text reference D25 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 53 SW25B)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 53 SW25B)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97378) + (at 208.2 105.175 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727D79) + (autoplace_cost180 10) + (fp_text reference D24 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 29 "Net-(D24-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 29 "Net-(D24-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9736B) + (at 188.5 106.75 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727BFE) + (autoplace_cost180 10) + (fp_text reference D23 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 28 "Net-(D23-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 28 "Net-(D23-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9735E) + (at 169.25 102.15 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727A89) + (autoplace_cost180 10) + (fp_text reference D22 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 27 "Net-(D22-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 27 "Net-(D22-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97351) + (at 150 98.565 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727929) + (autoplace_cost180 10) + (fp_text reference D21 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 26 "Net-(D21-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 26 "Net-(D21-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97344) + (at 131 103.175 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7277CE) + (autoplace_cost180 10) + (fp_text reference D20 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 25 "Net-(D20-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 25 "Net-(D20-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97337) + (at 112 102.75 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72767A) + (autoplace_cost180 10) + (fp_text reference D19 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9732A) + (at 207.75 86.275 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B725AA2) + (autoplace_cost180 10) + (fp_text reference D18 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 23 "Net-(D18-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 23 "Net-(D18-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9731D) + (at 188.5 88.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72596D) + (autoplace_cost180 10) + (fp_text reference D17 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 22 "Net-(D17-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 22 "Net-(D17-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97310) + (at 169.725 83.425 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B725841) + (autoplace_cost180 10) + (fp_text reference D16 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 21 "Net-(D16-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 21 "Net-(D16-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97303) + (at 149.75 81.565 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72571C) + (autoplace_cost180 10) + (fp_text reference D15 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 20 "Net-(D15-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 20 "Net-(D15-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972F6) + (at 131.25 83.675 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7255FF) + (autoplace_cost180 10) + (fp_text reference D14 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 19 "Net-(D14-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 19 "Net-(D14-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972E9) + (at 128.5 83.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7254EE) + (autoplace_cost180 10) + (fp_text reference D13 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972DC) + (at 207.75 67.275 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7243C0) + (autoplace_cost180 10) + (fp_text reference D12 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 17 "Net-(D12-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 17 "Net-(D12-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972CF) + (at 188.25 66.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72424D) + (autoplace_cost180 10) + (fp_text reference D11 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 16 "Net-(D11-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 16 "Net-(D11-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972C2) + (at 169.5 63.65 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7240EA) + (autoplace_cost180 10) + (fp_text reference D10 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 15 "Net-(D10-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 15 "Net-(D10-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972B5) + (at 150.25 61.065 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723FA1) + (autoplace_cost180 10) + (fp_text reference D9 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 14 "Net-(D9-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 14 "Net-(D9-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972A8) + (at 129.8 63.8 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723E5F) + (autoplace_cost180 10) + (fp_text reference D8 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 13 "Net-(D8-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 13 "Net-(D8-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9729B) + (at 126.8 63.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723D94) + (autoplace_cost180 10) + (fp_text reference D7 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9728E) + (at 207.75 50.025 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722FE1) + (autoplace_cost180 10) + (fp_text reference D6 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 10 "Net-(D6-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 10 "Net-(D6-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97281) + (at 188 50.25 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722BAD) + (autoplace_cost180 10) + (fp_text reference D5 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 8 "Net-(D5-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 8 "Net-(D5-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97274) + (at 169.25 45.425 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722A8F) + (autoplace_cost180 10) + (fp_text reference D4 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 6 "Net-(D4-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 6 "Net-(D4-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97267) + (at 150.5 43.04 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722950) + (autoplace_cost180 10) + (fp_text reference D3 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 4 "Net-(D3-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 4 "Net-(D3-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9725A) + (at 131 45.7805 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722847) + (autoplace_cost180 10) + (fp_text reference D2 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 3 "Net-(D2-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 3 "Net-(D2-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9724D) + (at 128.75 45.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7226E7) + (autoplace_cost180 10) + (fp_text reference D1 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 1 "Net-(D1-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 1 "Net-(D1-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module SofleKeyboard-footprint:ProMicro (layer F.Cu) (tedit 5B8BDEB4) (tstamp 5B8BE963) + (at 101 56) + (path /5B722440) + (fp_text reference U1 (at 0 1.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value ProMicro (at 0 -0.8) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -10.09 14.44) (end -10.09 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) + (pad 22 thru_hole circle (at -7.521185 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 43 RESET)) + (pad 10 thru_hole circle (at 7.718815 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 9 row2)) + (pad 18 thru_hole circle (at -7.521185 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 35 col0)) + (pad 6 thru_hole circle (at 7.718815 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 42 SCL)) + (pad 4 thru_hole circle (at 7.718815 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 14 thru_hole circle (at -7.521185 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 39 col4)) + (pad 3 thru_hole circle (at 7.718815 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 1 thru_hole circle (at 7.718815 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 41 LED)) + (pad 16 thru_hole circle (at -7.521185 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 37 col2)) + (pad 12 thru_hole circle (at 7.718815 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 2 row4)) + (pad 19 thru_hole circle (at -7.521185 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 55 ENCB)) + (pad 23 thru_hole circle (at -7.521185 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 21 thru_hole circle (at -7.521185 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 33 VCC)) + (pad 20 thru_hole circle (at -7.521185 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 56 ENCA)) + (pad 15 thru_hole circle (at -7.521185 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 38 col3)) + (pad 17 thru_hole circle (at -7.521185 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 36 col1)) + (pad 9 thru_hole circle (at 7.718815 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 7 row1)) + (pad 8 thru_hole circle (at 7.718815 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 5 row0)) + (pad 13 thru_hole circle (at -7.521185 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 54 SW25A)) + (pad 11 thru_hole circle (at 7.718815 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 11 row3)) + (pad 2 thru_hole circle (at 7.718815 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 47 DATA)) + (pad 24 thru_hole circle (at -7.521185 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 45 "Net-(U1-Pad24)")) + (pad 7 thru_hole circle (at 7.718815 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 46 "Net-(U1-Pad7)")) + (pad 5 thru_hole circle (at 7.718815 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 40 SDA)) + (pad 1 thru_hole circle (at -8.82 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 41 LED)) + (pad 2 thru_hole circle (at -8.82 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 47 DATA)) + (pad 3 thru_hole circle (at -8.82 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 4 thru_hole circle (at -8.82 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 5 thru_hole circle (at -8.82 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 40 SDA)) + (pad 6 thru_hole circle (at -8.82 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 42 SCL)) + (pad 7 thru_hole circle (at -8.82 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 46 "Net-(U1-Pad7)")) + (pad 8 thru_hole circle (at -8.82 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 5 row0)) + (pad 9 thru_hole circle (at -8.82 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 7 row1)) + (pad 10 thru_hole circle (at -8.82 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 9 row2)) + (pad 11 thru_hole circle (at -8.82 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 11 row3)) + (pad 12 thru_hole circle (at -8.82 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 2 row4)) + (pad 13 thru_hole circle (at 6.42 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 54 SW25A)) + (pad 14 thru_hole circle (at 6.42 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 39 col4)) + (pad 15 thru_hole circle (at 6.42 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 38 col3)) + (pad 16 thru_hole circle (at 6.42 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 37 col2)) + (pad 17 thru_hole circle (at 6.42 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 36 col1)) + (pad 18 thru_hole circle (at 6.42 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 35 col0)) + (pad 19 thru_hole circle (at 6.42 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 55 ENCB)) + (pad 20 thru_hole circle (at 6.42 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 56 ENCA)) + (pad 21 thru_hole circle (at 6.42 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (pad 22 thru_hole circle (at 6.42 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 43 RESET)) + (pad 23 thru_hole circle (at 6.42 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 24 thru_hole circle (at 6.42 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 45 "Net-(U1-Pad24)")) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5D8BB010) + (at 107 93.5) + (path /5B74D0C7) + (fp_text reference TH2 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5BE98A92) + (at 91.5 93.5) + (path /5B74CE27) + (fp_text reference TH1 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:OLED_4Pin (layer F.Cu) (tedit 59FC8837) (tstamp 5BEDDC3B) + (at 96.7 74.6) + (descr "Connecteur 6 pins") + (tags "CONN DEV") + (path /5B91007B) + (fp_text reference J3 (at -1.915 1.93 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value OLED (at 3.81 1.27) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) + (pad 4 thru_hole circle (at 7.62 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 51 "Net-(J3-Pad4)")) + (pad 3 thru_hole circle (at 5.08 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 50 "Net-(J3-Pad3)")) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 49 "Net-(J3-Pad2)")) + (pad 1 thru_hole circle (at 0 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 48 "Net-(J3-Pad1)")) + ) + + (module SofleKeyboard-footprint:jumper_data (layer F.Cu) (tedit 5D87BC97) (tstamp 5BE95B4C) + (at 94 75 270) + (path /5B900157) + (attr smd) + (fp_text reference W1 (at -1.8 0) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value jumper (at 0 1.524 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) + (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 47 DATA) (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 58 /i2c_d) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:TACT_SWITCH_TVBP06 (layer F.Cu) (tedit 5B8CD44F) (tstamp 5BE9586C) + (at 90 77.5 270) + (path /5B8CE7E7) + (fp_text reference RSW1 (at 0 -1.7 90) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_RST (at 0 2 90) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -3 -1.8) (end 2.9 -1.8) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (pad 2 thru_hole circle (at 3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) + (net 43 RESET)) + (pad 1 thru_hole circle (at -3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) + (net 34 GND)) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95857) + (at 96.7 69.3 90) + (path /5B914206) + (attr smd) + (fp_text reference JP8 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 34 GND) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE9584D) + (at 99.2 69.3 90) + (path /5B914200) + (attr smd) + (fp_text reference JP7 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 33 VCC) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95843) + (at 101.7 69.3 90) + (path /5B9141FA) + (attr smd) + (fp_text reference JP6 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 42 SCL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE98BB2) + (at 104.3 69.3 90) + (path /5B9141F4) + (attr smd) + (fp_text reference JP5 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 40 SDA) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE98C76) + (at 96.7 69.3 90) + (path /5B913C11) + (attr smd) + (fp_text reference JP4 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 40 SDA) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95825) + (at 99.2 69.3 90) + (path /5B913646) + (attr smd) + (fp_text reference JP3 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 42 SCL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE9581B) + (at 101.7 69.3 90) + (path /5B9120CE) + (attr smd) + (fp_text reference JP2 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 33 VCC) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95811) + (at 104.3 69.3 90) + (path /5B911E74) + (attr smd) + (fp_text reference JP1 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 34 GND) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B7351FC) + (at 98.039272 80.311965) + (descr "Resitance 3 pas") + (tags R) + (path /5B739F4A) + (autoplace_cost180 10) + (fp_text reference R1 (at -0.039272 -0.011965 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_text user R1 (at 0 -0.011965 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 40 SDA)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B735209) + (at 98.039272 78.061965) + (descr "Resitance 3 pas") + (tags R) + (path /5B73A034) + (autoplace_cost180 10) + (fp_text reference R2 (at -0.039272 0.038035 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_text user R2 (at 0 0 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 42 SCL)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE93F) + (at 102.7 78.1 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B8F6980) + (autoplace_cost180 10) + (fp_text reference P2 (at 0 -1.671944 270) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_text user P1 (at -0.1 1.7 270) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_text user P2 (at 0 -1.7 270) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE931) + (at 102.7 80.3 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B8F6780) + (autoplace_cost180 10) + (fp_text reference P1 (at 0 -1.671944 270) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_text user P1 (at 0.2 -1.7 270) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BFE) (tstamp 5B8BE95D) + (at 206.175 100.025) + (path /5B74D88C) + (fp_text reference TH6 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.175 -0.025 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BD0) (tstamp 5B8BE958) + (at 130.025 97.575) + (path /5B74D78B) + (fp_text reference TH5 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5B8BE94E) + (at 129.975 57.075) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified (layer F.Cu) (tedit 5D5C0C22) (tstamp 5D8CBBBB) + (at 100 104.5) + (descr "Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html") + (tags "rotary encoder") + (path /5DA04574) + (fp_text reference SW25 (at 4.24 4.6) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value Rotary_Encoder_Switch (at 0 7.9) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) + (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) + (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) + (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer B.SilkS) (width 0.12)) + (pad S1 thru_hole circle (at 7 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 54 SW25A)) + (pad S2 thru_hole circle (at 7 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 53 SW25B)) + (pad MP thru_hole rect (at 0 5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad MP thru_hole rect (at 0 -5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad B thru_hole circle (at -7.5 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 55 ENCB)) + (pad C thru_hole circle (at -7.5 0) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 34 GND)) + (pad A thru_hole circle (at -7.5 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 56 ENCA)) + (model ${KISYS3DMOD}/Rotary_Encoder.3dshapes/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 1 1 1)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F8059EF) (tstamp 5B8BE962) + (at 103 119 90) + (path /5B74D98F) + (fp_text reference TH7 (at 0 -2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at 0 0 180) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805C11) (tstamp 5B8BE953) + (at 206.225 61.775) + (path /5B74D1C0) + (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:MJ-4PP-9 (layer F.Cu) (tedit 5D8BAE3B) (tstamp 5B8BE8A5) + (at 88 85.65 90) + (path /5B742D8C) + (fp_text reference J2 (at -0.889 6.4135 90) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value 4PIN (at 0 14 90) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) + (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" np_thru_hole circle (at -1.75 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at -1.75 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad 1 thru_hole oval (at -3.85 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC) (clearance 0.15)) + (pad 4 thru_hole oval (at 0.35 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c) (clearance 0.15)) + (pad 3 thru_hole oval (at -3.85 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (pad 2 thru_hole oval (at -3.85 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad "" np_thru_hole circle (at 0 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at 0 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad 3 thru_hole oval (at 2.1 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (pad 2 thru_hole oval (at 2.1 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 1 thru_hole oval (at 2.1 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC) (clearance 0.15)) + (pad 4 thru_hole oval (at -2.1 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c) (clearance 0.15)) + (model "../../../../../../Users/pluis/Documents/Magic Briefcase/Documents/KiCad/3d/AB2_TRS_3p5MM_PTH.wrl" + (at (xyz 0 0 0)) + (scale (xyz 0.42 0.42 0.42)) + (rotate (xyz 0 0 90)) + ) + ) + + (gr_text "Sofle RGB by Dane Evans, original by Josef Adamacik" (at 113.75 39) (layer F.SilkS) (tstamp 5FDB143C) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_text s6 (at 215.5 47) (layer Eco1.User) (tstamp 5FB24AE6) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s5 (at 196.5 47) (layer Eco1.User) (tstamp 5FB24AE6) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s16 (at 177.5 80) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s15 (at 158.5 77.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s14 (at 139.5 80) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s12 (at 215.5 65.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s11 (at 196.5 65.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s10 (at 178 61) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s9 (at 158.5 58.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s8 (at 139.5 61) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s4 (at 177.5 42) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s3 (at 158.5 39.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s2 (at 139.5 41.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s1 (at 120.5 44.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s7 (at 120.5 63) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s13 (at 120.5 82.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s18 (at 215.5 85) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s17 (at 196.5 85) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s22 (at 177.5 99) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s21\n" (at 158.5 97) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s20\n" (at 139.5 99) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s19\n" (at 120.5 101.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s24 (at 215.5 104) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s23\n" (at 196.5 104) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s30\n" (at 177.5 118) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s29\n" (at 158.5 116) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s28\n" (at 139.5 118.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text s27 (at 116 123.5) (layer Eco1.User) (tstamp 5FB24A22) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text "s26\n" (at 96 133) (layer Eco1.User) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_circle (center 206 100) (end 208 100) (layer Eco2.User) (width 0.15) (tstamp 5F80A7FB)) + (gr_circle (center 103 119) (end 105 119) (layer Eco2.User) (width 0.15) (tstamp 5F80A7FB)) + (gr_circle (center 206 61.5) (end 208 61.5) (layer Eco2.User) (width 0.15) (tstamp 5F809B7A)) + (gr_circle (center 130 57) (end 132 57) (layer Eco2.User) (width 0.15)) + (gr_circle (center 130 97.5) (end 132 97.5) (layer Eco2.User) (width 0.15)) + (gr_line (start 179.3488 116.0352) (end 179.3488 120.5352) (layer Edge.Cuts) (width 0.15) (tstamp 5F80961C)) + (gr_line (start 179.35 97.05) (end 179.35 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F80961B)) + (gr_line (start 160.3504 113.5362) (end 160.3504 118.0362) (layer Edge.Cuts) (width 0.15) (tstamp 5F80961A)) + (gr_line (start 194.95 82.75) (end 198.45 82.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F809619)) + (gr_line (start 141.2504 120.4492) (end 137.7504 120.4492) (layer Edge.Cuts) (width 0.15) (tstamp 5F809618)) + (gr_line (start 160.35 98.9308) (end 156.85 98.9308) (layer Edge.Cuts) (width 0.15) (tstamp 5F809617)) + (gr_line (start 118.75 99.35) (end 122.25 99.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F809616)) + (gr_line (start 137.7504 115.9492) (end 141.2504 115.9492) (layer Edge.Cuts) (width 0.15) (tstamp 5F809615)) + (gr_line (start 156.85 75.4562) (end 160.35 75.4562) (layer Edge.Cuts) (width 0.15) (tstamp 5F809614)) + (gr_line (start 194.95 101.75) (end 198.45 101.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F809613)) + (gr_line (start 156.85 79.9562) (end 156.85 75.4562) (layer Edge.Cuts) (width 0.15) (tstamp 5F809612)) + (gr_line (start 137.7504 120.4492) (end 137.7504 115.9492) (layer Edge.Cuts) (width 0.15) (tstamp 5F809611)) + (gr_line (start 118.75 103.85) (end 118.75 99.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F809610)) + (gr_line (start 137.75 97.05) (end 141.25 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960F)) + (gr_line (start 175.85 97.05) (end 179.35 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960E)) + (gr_line (start 160.35 75.4562) (end 160.35 79.9562) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960D)) + (gr_line (start 179.3488 120.5352) (end 175.8488 120.5352) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960C)) + (gr_line (start 217.5 101.726) (end 217.5 106.226) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960B)) + (gr_line (start 214 106.226) (end 214 101.726) (layer Edge.Cuts) (width 0.15) (tstamp 5F80960A)) + (gr_line (start 217.5 106.226) (end 214 106.226) (layer Edge.Cuts) (width 0.15) (tstamp 5F809609)) + (gr_line (start 198.45 106.25) (end 194.95 106.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F809608)) + (gr_line (start 175.8488 116.0352) (end 179.3488 116.0352) (layer Edge.Cuts) (width 0.15) (tstamp 5F809607)) + (gr_line (start 175.8488 120.5352) (end 175.8488 116.0352) (layer Edge.Cuts) (width 0.15) (tstamp 5F809606)) + (gr_line (start 156.8504 113.5362) (end 160.3504 113.5362) (layer Edge.Cuts) (width 0.15) (tstamp 5F809605)) + (gr_line (start 141.25 97.05) (end 141.25 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F809604)) + (gr_line (start 198.45 87.25) (end 194.95 87.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F809603)) + (gr_line (start 175.85 77.95) (end 179.35 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F809602)) + (gr_line (start 156.85 94.4308) (end 160.35 94.4308) (layer Edge.Cuts) (width 0.15) (tstamp 5F809601)) + (gr_line (start 160.35 94.4308) (end 160.35 98.9308) (layer Edge.Cuts) (width 0.15) (tstamp 5F809600)) + (gr_line (start 179.35 77.95) (end 179.35 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FF)) + (gr_line (start 194.95 87.25) (end 194.95 82.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FE)) + (gr_line (start 156.8504 118.0362) (end 156.8504 113.5362) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FD)) + (gr_line (start 160.3504 118.0362) (end 156.8504 118.0362) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FC)) + (gr_line (start 141.2504 115.9492) (end 141.2504 120.4492) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FB)) + (gr_line (start 122.25 99.35) (end 122.25 103.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095FA)) + (gr_line (start 198.45 101.75) (end 198.45 106.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F9)) + (gr_line (start 175.85 101.55) (end 175.85 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F8)) + (gr_line (start 122.25 103.85) (end 118.75 103.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F7)) + (gr_line (start 137.75 101.55) (end 137.75 97.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F6)) + (gr_line (start 156.85 98.9308) (end 156.85 94.4308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F5)) + (gr_line (start 175.85 82.45) (end 175.85 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F4)) + (gr_line (start 179.35 101.55) (end 175.85 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F3)) + (gr_line (start 198.45 82.75) (end 198.45 87.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F2)) + (gr_line (start 194.95 106.25) (end 194.95 101.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F1)) + (gr_line (start 179.35 82.45) (end 175.85 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095F0)) + (gr_line (start 141.25 101.55) (end 137.75 101.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095EF)) + (gr_line (start 138.154128 134) (end 93.9 146.75) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095EE)) + (gr_line (start 217.45 82.7895) (end 217.45 87.2895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095ED)) + (gr_line (start 225.026621 43.6956) (end 225.168321 43.835582) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095EC)) + (gr_line (start 122.25 46.75) (end 118.75 46.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095EB)) + (gr_line (start 175.85 39.85) (end 179.35 39.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095EA)) + (gr_line (start 179.35 44.35) (end 175.85 44.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E9)) + (gr_line (start 213.95 63.526) (end 217.45 63.526) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E8)) + (gr_line (start 156.85 41.7308) (end 156.85 37.2308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E7)) + (gr_line (start 89.19368 37.348815) (end 89.425853 37.325405) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095E6)) + (gr_line (start 88.977436 37.415945) (end 89.19368 37.348815) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095E5)) + (gr_line (start 149 35) (end 170.95 35) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095E4)) + (gr_line (start 118.75 42.25) (end 122.25 42.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E3)) + (gr_line (start 137.75 39.7484) (end 141.25 39.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E2)) + (gr_line (start 160.35 37.2308) (end 160.35 41.7308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E1)) + (gr_line (start 194.95 49.15) (end 194.95 44.65) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095E0)) + (gr_line (start 198.45 68.05) (end 194.95 68.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DF)) + (gr_line (start 122.25 42.25) (end 122.25 46.75) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DE)) + (gr_line (start 118.75 46.75) (end 118.75 42.25) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DD)) + (gr_line (start 213.95 49.1514) (end 213.95 44.6514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DC)) + (gr_line (start 194.95 63.55) (end 198.45 63.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DB)) + (gr_line (start 160.35 41.7308) (end 156.85 41.7308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095DA)) + (gr_line (start 213.95 82.7895) (end 217.45 82.7895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D9)) + (gr_line (start 214 101.726) (end 217.5 101.726) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D8)) + (gr_line (start 141.25 44.2484) (end 137.75 44.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D7)) + (gr_line (start 198.45 63.55) (end 198.45 68.05) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D6)) + (gr_line (start 198.45 49.15) (end 194.95 49.15) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D5)) + (gr_line (start 224.861871 43.581466) (end 225.026621 43.6956) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095D4)) + (gr_line (start 137.75 44.2484) (end 137.75 39.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D3)) + (gr_line (start 213.95 44.6514) (end 217.45 44.6514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D2)) + (gr_line (start 225.168321 43.835582) (end 225.283881 43.997807) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095D1)) + (gr_line (start 179.35 39.85) (end 179.35 44.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095D0)) + (gr_line (start 198.45 44.65) (end 198.45 49.15) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CF)) + (gr_line (start 217.45 44.6514) (end 217.45 49.1514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CE)) + (gr_line (start 213.95 68.026) (end 213.95 63.526) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CD)) + (gr_line (start 194.95 44.65) (end 198.45 44.65) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CC)) + (gr_line (start 217.45 63.526) (end 217.45 68.026) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095CB)) + (gr_line (start 88.275257 114.4) (end 88.273857 38.477435) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095CA)) + (gr_line (start 175.85 44.35) (end 175.85 39.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C9)) + (gr_line (start 217.45 49.1514) (end 213.95 49.1514) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C8)) + (gr_line (start 194.95 68.05) (end 194.95 63.55) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C7)) + (gr_line (start 217.45 87.2895) (end 213.95 87.2895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C6)) + (gr_line (start 217.45 68.026) (end 213.95 68.026) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C5)) + (gr_line (start 141.25 39.7484) (end 141.25 44.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C4)) + (gr_line (start 213.95 87.2895) (end 213.95 82.7895) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C3)) + (gr_line (start 156.85 37.2308) (end 160.35 37.2308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C2)) + (gr_line (start 137.75 82.45) (end 137.75 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C1)) + (gr_line (start 118.75 80.35) (end 122.25 80.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095C0)) + (gr_line (start 179.35 58.7484) (end 179.35 63.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BF)) + (gr_line (start 160.35 60.8308) (end 156.85 60.8308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BE)) + (gr_line (start 118.75 84.85) (end 118.75 80.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BD)) + (gr_line (start 118.75 65.85) (end 118.75 61.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BC)) + (gr_line (start 175.85 58.7484) (end 179.35 58.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BB)) + (gr_line (start 137.75 63.45) (end 137.75 58.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095BA)) + (gr_line (start 122.25 84.85) (end 118.75 84.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B9)) + (gr_line (start 141.25 63.45) (end 137.75 63.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B8)) + (gr_line (start 122.25 80.35) (end 122.25 84.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B7)) + (gr_line (start 118.75 61.35) (end 122.25 61.35) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B6)) + (gr_line (start 156.85 56.3308) (end 160.35 56.3308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B5)) + (gr_line (start 156.85 60.8308) (end 156.85 56.3308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B4)) + (gr_line (start 122.25 61.35) (end 122.25 65.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B3)) + (gr_line (start 141.25 58.95) (end 141.25 63.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B2)) + (gr_line (start 160.35 79.9562) (end 156.85 79.9562) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B1)) + (gr_line (start 141.25 82.45) (end 137.75 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095B0)) + (gr_line (start 122.25 65.85) (end 118.75 65.85) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AF)) + (gr_line (start 160.35 56.3308) (end 160.35 60.8308) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AE)) + (gr_line (start 137.75 58.95) (end 141.25 58.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AD)) + (gr_line (start 137.75 77.95) (end 141.25 77.95) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AC)) + (gr_line (start 141.25 77.95) (end 141.25 82.45) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AB)) + (gr_line (start 113.952287 121.332) (end 117.333027 120.426134) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095AA)) + (gr_line (start 225.470181 119.5) (end 187.5 134) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A9)) + (gr_line (start 92.9 146.5) (end 93.35 146.65) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A8)) + (gr_line (start 102.5164 128.0486) (end 104.2664 131.079688) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A7)) + (gr_line (start 100.369286 133.329688) (end 98.619286 130.2986) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A6)) + (gr_line (start 82.15 127.9) (end 82.1 127.3) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A5)) + (gr_line (start 93.35 146.65) (end 93.9 146.75) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A4)) + (gr_line (start 175.85 63.2484) (end 175.85 58.7484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A3)) + (gr_line (start 88.2 115.05) (end 88 115.65) (layer Edge.Cuts) (width 0.1) (tstamp 5F8095A2)) + (gr_line (start 117.333027 120.426134) (end 118.497713 124.7728) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A1)) + (gr_line (start 179.35 63.2484) (end 175.85 63.2484) (layer Edge.Cuts) (width 0.15) (tstamp 5F8095A0)) + (gr_line (start 82.1 127.3) (end 82.1 126.9) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959F)) + (gr_line (start 115.116973 125.678666) (end 113.952287 121.332) (layer Edge.Cuts) (width 0.15) (tstamp 5F80959E)) + (gr_line (start 82.1 126.9) (end 82.2 126.4) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959D)) + (gr_line (start 82.3 128.4) (end 82.15 127.9) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959C)) + (gr_line (start 88.275257 114.4) (end 88.2 115.05) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959B)) + (gr_line (start 149 35) (end 89.425853 37.325405) (layer Edge.Cuts) (width 0.1) (tstamp 5F80959A)) + (gr_line (start 138.154128 134) (end 187.5 134) (layer Edge.Cuts) (width 0.1) (tstamp 5F809599)) + (gr_line (start 92.55 146.2) (end 92.9 146.5) (layer Edge.Cuts) (width 0.1) (tstamp 5F809598)) + (gr_line (start 98.619286 130.2986) (end 102.5164 128.0486) (layer Edge.Cuts) (width 0.15) (tstamp 5F809597)) + (gr_line (start 118.497713 124.7728) (end 115.116973 125.678666) (layer Edge.Cuts) (width 0.15) (tstamp 5F809596)) + (gr_line (start 104.2664 131.079688) (end 100.369286 133.329688) (layer Edge.Cuts) (width 0.15) (tstamp 5F809595)) + (gr_line (start 88.47059 37.833327) (end 88.611259 37.662831) (layer Edge.Cuts) (width 0.1) (tstamp 5F809594)) + (gr_line (start 224.475441 43.445146) (end 224.677111 43.496776) (layer Edge.Cuts) (width 0.1) (tstamp 5F809593)) + (gr_line (start 224.677111 43.496776) (end 224.861871 43.581466) (layer Edge.Cuts) (width 0.1) (tstamp 5F809592)) + (gr_line (start 88.273857 38.477435) (end 88.297257 38.245261) (layer Edge.Cuts) (width 0.1) (tstamp 5F809591)) + (gr_line (start 88.364377 38.029014) (end 88.47059 37.833327) (layer Edge.Cuts) (width 0.1) (tstamp 5F809590)) + (gr_line (start 82.2 126.4) (end 88 115.65) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958F)) + (gr_line (start 225.370281 44.178672) (end 225.424381 44.374571) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958E)) + (gr_line (start 88.781752 37.52216) (end 88.977436 37.415945) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958D)) + (gr_line (start 225.424381 44.374571) (end 225.443181 44.581902) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958C)) + (gr_line (start 88.611259 37.662831) (end 88.781752 37.52216) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958B)) + (gr_line (start 225.443181 44.581902) (end 225.470181 119.5) (layer Edge.Cuts) (width 0.1) (tstamp 5F80958A)) + (gr_line (start 88.297257 38.245261) (end 88.364377 38.029014) (layer Edge.Cuts) (width 0.1) (tstamp 5F809589)) + (gr_line (start 170.95 35) (end 224.475441 43.445146) (layer Edge.Cuts) (width 0.1) (tstamp 5F809588)) + (gr_line (start 92.55 146.2) (end 82.3 128.4) (layer Edge.Cuts) (width 0.1) (tstamp 5F809587)) + (gr_line (start 225.283881 43.997807) (end 225.370281 44.178672) (layer Edge.Cuts) (width 0.1) (tstamp 5F809586)) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 155.75 132.5) (layer F.SilkS) (tstamp 5F80515B) + (effects (font (size 1 1) (thickness 0.15))) + ) + (gr_text https://josefadamcik.github.io/SofleKeyboard/ (at 156.9182 132.4021) (layer B.SilkS) (tstamp 5F80515B) + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (gr_text "Sofle RGB by Dane Evans, original by Josef Adamacik" (at 113.75 39) (layer B.SilkS) (tstamp 5F8089F3) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Sofle RGB v3, Dane Evans, JCliment\n" (at 201.4474 127.0762 21) (layer B.Cu) (tstamp 5F80858D) + (effects (font (size 1 1) (thickness 0.2)) (justify mirror)) + ) + (gr_text "Sofle RGB v3, Dane Evans, JCliment" (at 201.3458 127.1016 21) (layer F.Cu) + (effects (font (size 1 1) (thickness 0.2))) + ) + (gr_line (start 93.35 146.65) (end 93.9 146.75) (layer Cmts.User) (width 0.1) (tstamp 5F809492)) + (gr_line (start 92.9 146.5) (end 93.35 146.65) (layer Cmts.User) (width 0.1) (tstamp 5F809486)) + (gr_line (start 92.55 146.2) (end 92.9 146.5) (layer Cmts.User) (width 0.1) (tstamp 5F8094B6)) + (gr_line (start 88.2 115.05) (end 88 115.65) (layer Cmts.User) (width 0.1) (tstamp 5F809498)) + (gr_line (start 88.275257 114.4) (end 88.2 115.05) (layer Cmts.User) (width 0.1) (tstamp 5F8094AD)) + (gr_line (start 82.1 126.9) (end 82.2 126.4) (layer Cmts.User) (width 0.1) (tstamp 5F8094A7)) + (gr_line (start 82.1 127.3) (end 82.1 126.9) (layer Cmts.User) (width 0.1) (tstamp 5F8094A1)) + (gr_line (start 82.15 127.9) (end 82.1 127.3) (layer Cmts.User) (width 0.1) (tstamp 5F80948F)) + (gr_line (start 82.3 128.4) (end 82.15 127.9) (layer Cmts.User) (width 0.1) (tstamp 5F8094AA)) + (gr_line (start 149 35) (end 89.19368 37.348815) (layer Cmts.User) (width 0.1) (tstamp 5F8094B0)) + (gr_line (start 225.5 119.5) (end 187.5 134) (layer Cmts.User) (width 0.15) (tstamp 5F809483)) + (gr_line (start 138.154128 134) (end 187.5 134) (layer Cmts.User) (width 0.1) (tstamp 5F8094B3)) + (gr_text "Ind bypass" (at 114.173 82.804 90) (layer F.SilkS) (tstamp 5F77E038) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_text "BL bypass" (at 187.2234 99.3648 90) (layer F.SilkS) (tstamp 5F77D431) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_text "Ind bypass" (at 114.173 82.804 90) (layer B.SilkS) (tstamp 5F77CE5F) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (gr_text VCC (at 110.109 81.026) (layer F.SilkS) (tstamp 5F77CE5F) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_text LED (at 110.0582 78.613) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (gr_line (start 104.2664 131.079688) (end 100.369286 133.329688) (layer Cmts.User) (width 0.15) (tstamp 5F8094BF)) + (gr_line (start 98.619286 130.2986) (end 102.5164 128.0486) (layer Cmts.User) (width 0.15) (tstamp 5F8094B9)) + (gr_line (start 100.369286 133.329688) (end 98.619286 130.2986) (layer Cmts.User) (width 0.15) (tstamp 5F80948C)) + (gr_line (start 102.5164 128.0486) (end 104.2664 131.079688) (layer Cmts.User) (width 0.15) (tstamp 5F809489)) + (gr_line (start 113.952287 121.332) (end 117.333027 120.426134) (layer Cmts.User) (width 0.15) (tstamp 5F809480)) + (gr_line (start 118.497713 124.7728) (end 115.116973 125.678666) (layer Cmts.User) (width 0.15) (tstamp 5F8094BC)) + (gr_line (start 115.116973 125.678666) (end 113.952287 121.332) (layer Cmts.User) (width 0.15) (tstamp 5F8094A4)) + (gr_line (start 117.333027 120.426134) (end 118.497713 124.7728) (layer Cmts.User) (width 0.15) (tstamp 5F80949B)) + (gr_line (start 179.35 63.2484) (end 175.85 63.2484) (layer Cmts.User) (width 0.15) (tstamp 5F80949E)) + (gr_line (start 175.85 63.2484) (end 175.85 58.7484) (layer Cmts.User) (width 0.15) (tstamp 5F809495)) + (gr_line (start 179.35 58.7484) (end 179.35 63.2484) (layer Cmts.User) (width 0.15) (tstamp 5F809441)) + (gr_line (start 175.85 58.7484) (end 179.35 58.7484) (layer Cmts.User) (width 0.15) (tstamp 5F80944D)) + (gr_line (start 160.35 60.8308) (end 156.85 60.8308) (layer Cmts.User) (width 0.15) (tstamp 5F809444)) + (gr_line (start 156.85 60.8308) (end 156.85 56.3308) (layer Cmts.User) (width 0.15) (tstamp 5F809462)) + (gr_line (start 160.35 56.3308) (end 160.35 60.8308) (layer Cmts.User) (width 0.15) (tstamp 5F809474)) + (gr_line (start 156.85 56.3308) (end 160.35 56.3308) (layer Cmts.User) (width 0.15) (tstamp 5F80945F)) + (gr_line (start 141.25 63.45) (end 137.75 63.45) (layer Cmts.User) (width 0.15) (tstamp 5F809456)) + (gr_line (start 137.75 63.45) (end 137.75 58.95) (layer Cmts.User) (width 0.15) (tstamp 5F809450)) + (gr_line (start 141.25 58.95) (end 141.25 63.45) (layer Cmts.User) (width 0.15) (tstamp 5F809468)) + (gr_line (start 137.75 58.95) (end 141.25 58.95) (layer Cmts.User) (width 0.15) (tstamp 5F809477)) + (gr_line (start 122.25 65.85) (end 118.75 65.85) (layer Cmts.User) (width 0.15) (tstamp 5F809471)) + (gr_line (start 118.75 65.85) (end 118.75 61.35) (layer Cmts.User) (width 0.15) (tstamp 5F80944A)) + (gr_line (start 122.25 61.35) (end 122.25 65.85) (layer Cmts.User) (width 0.15) (tstamp 5F809465)) + (gr_line (start 118.75 61.35) (end 122.25 61.35) (layer Cmts.User) (width 0.15) (tstamp 5F80945C)) + (gr_line (start 122.25 84.85) (end 118.75 84.85) (layer Cmts.User) (width 0.15) (tstamp 5F809453)) + (gr_line (start 118.75 84.85) (end 118.75 80.35) (layer Cmts.User) (width 0.15) (tstamp 5F809447)) + (gr_line (start 122.25 80.35) (end 122.25 84.85) (layer Cmts.User) (width 0.15) (tstamp 5F809459)) + (gr_line (start 118.75 80.35) (end 122.25 80.35) (layer Cmts.User) (width 0.15) (tstamp 5F80943E)) + (gr_line (start 141.25 82.45) (end 137.75 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F80946E)) + (gr_line (start 137.75 82.45) (end 137.75 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F80943B)) + (gr_line (start 141.25 77.95) (end 141.25 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F80947D)) + (gr_line (start 137.75 77.95) (end 141.25 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F80947A)) + (gr_line (start 160.35 79.9562) (end 156.85 79.9562) (layer Cmts.User) (width 0.15) (tstamp 5F80946B)) + (gr_line (start 156.85 79.9562) (end 156.85 75.4562) (layer Cmts.User) (width 0.15) (tstamp 5F809348)) + (gr_line (start 160.35 75.4562) (end 160.35 79.9562) (layer Cmts.User) (width 0.15) (tstamp 5F809357)) + (gr_line (start 156.85 75.4562) (end 160.35 75.4562) (layer Cmts.User) (width 0.15) (tstamp 5F809342)) + (gr_line (start 179.35 82.45) (end 175.85 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F8093AE)) + (gr_line (start 175.85 82.45) (end 175.85 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F8093A2)) + (gr_line (start 179.35 77.95) (end 179.35 82.45) (layer Cmts.User) (width 0.15) (tstamp 5F809381)) + (gr_line (start 175.85 77.95) (end 179.35 77.95) (layer Cmts.User) (width 0.15) (tstamp 5F809378)) + (gr_line (start 198.45 87.25) (end 194.95 87.25) (layer Cmts.User) (width 0.15) (tstamp 5F809375)) + (gr_line (start 194.95 87.25) (end 194.95 82.75) (layer Cmts.User) (width 0.15) (tstamp 5F809384)) + (gr_line (start 198.45 82.75) (end 198.45 87.25) (layer Cmts.User) (width 0.15) (tstamp 5F8093A8)) + (gr_line (start 194.95 82.75) (end 198.45 82.75) (layer Cmts.User) (width 0.15) (tstamp 5F809333)) + (gr_line (start 198.45 106.25) (end 194.95 106.25) (layer Cmts.User) (width 0.15) (tstamp 5F809366)) + (gr_line (start 194.95 106.25) (end 194.95 101.75) (layer Cmts.User) (width 0.15) (tstamp 5F8093AB)) + (gr_line (start 198.45 101.75) (end 198.45 106.25) (layer Cmts.User) (width 0.15) (tstamp 5F809393)) + (gr_line (start 194.95 101.75) (end 198.45 101.75) (layer Cmts.User) (width 0.15) (tstamp 5F809345)) + (gr_line (start 179.35 101.55) (end 175.85 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F8093A5)) + (gr_line (start 175.85 101.55) (end 175.85 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F809396)) + (gr_line (start 179.35 97.05) (end 179.35 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F80932D)) + (gr_line (start 175.85 97.05) (end 179.35 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F809354)) + (gr_line (start 160.35 98.9308) (end 156.85 98.9308) (layer Cmts.User) (width 0.15) (tstamp 5F809339)) + (gr_line (start 156.85 98.9308) (end 156.85 94.4308) (layer Cmts.User) (width 0.15) (tstamp 5F80939F)) + (gr_line (start 160.35 94.4308) (end 160.35 98.9308) (layer Cmts.User) (width 0.15) (tstamp 5F80937E)) + (gr_line (start 156.85 94.4308) (end 160.35 94.4308) (layer Cmts.User) (width 0.15) (tstamp 5F80937B)) + (gr_line (start 141.25 101.55) (end 137.75 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F8093B1)) + (gr_line (start 137.75 101.55) (end 137.75 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F80939C)) + (gr_line (start 141.25 97.05) (end 141.25 101.55) (layer Cmts.User) (width 0.15) (tstamp 5F809372)) + (gr_line (start 137.75 97.05) (end 141.25 97.05) (layer Cmts.User) (width 0.15) (tstamp 5F809351)) + (gr_line (start 122.25 103.85) (end 118.75 103.85) (layer Cmts.User) (width 0.15) (tstamp 5F809399)) + (gr_line (start 118.75 103.85) (end 118.75 99.35) (layer Cmts.User) (width 0.15) (tstamp 5F80934E)) + (gr_line (start 122.25 99.35) (end 122.25 103.85) (layer Cmts.User) (width 0.15) (tstamp 5F809390)) + (gr_line (start 118.75 99.35) (end 122.25 99.35) (layer Cmts.User) (width 0.15) (tstamp 5F80933C)) + (gr_line (start 141.2504 120.4492) (end 137.7504 120.4492) (layer Cmts.User) (width 0.15) (tstamp 5F809336)) + (gr_line (start 137.7504 120.4492) (end 137.7504 115.9492) (layer Cmts.User) (width 0.15) (tstamp 5F80934B)) + (gr_line (start 141.2504 115.9492) (end 141.2504 120.4492) (layer Cmts.User) (width 0.15) (tstamp 5F80938D)) + (gr_line (start 137.7504 115.9492) (end 141.2504 115.9492) (layer Cmts.User) (width 0.15) (tstamp 5F80933F)) + (gr_line (start 160.3504 118.0362) (end 156.8504 118.0362) (layer Cmts.User) (width 0.15) (tstamp 5F80938A)) + (gr_line (start 156.8504 118.0362) (end 156.8504 113.5362) (layer Cmts.User) (width 0.15) (tstamp 5F809387)) + (gr_line (start 160.3504 113.5362) (end 160.3504 118.0362) (layer Cmts.User) (width 0.15) (tstamp 5F809330)) + (gr_line (start 156.8504 113.5362) (end 160.3504 113.5362) (layer Cmts.User) (width 0.15) (tstamp 5F80936F)) + (gr_line (start 179.3488 120.5352) (end 175.8488 120.5352) (layer Cmts.User) (width 0.15) (tstamp 5F80935A)) + (gr_line (start 175.8488 120.5352) (end 175.8488 116.0352) (layer Cmts.User) (width 0.15) (tstamp 5F80936C)) + (gr_line (start 179.3488 116.0352) (end 179.3488 120.5352) (layer Cmts.User) (width 0.15) (tstamp 5F80932A)) + (gr_line (start 175.8488 116.0352) (end 179.3488 116.0352) (layer Cmts.User) (width 0.15) (tstamp 5F809369)) + (gr_line (start 217.5 106.226) (end 214 106.226) (layer Cmts.User) (width 0.15) (tstamp 5F809363)) + (gr_line (start 214 106.226) (end 214 101.726) (layer Cmts.User) (width 0.15) (tstamp 5F809360)) + (gr_line (start 217.5 101.726) (end 217.5 106.226) (layer Cmts.User) (width 0.15) (tstamp 5F80935D)) + (gr_line (start 214 101.726) (end 217.5 101.726) (layer Cmts.User) (width 0.15) (tstamp 5F8093F6)) + (gr_line (start 217.45 87.2895) (end 213.95 87.2895) (layer Cmts.User) (width 0.15) (tstamp 5F80942C)) + (gr_line (start 213.95 87.2895) (end 213.95 82.7895) (layer Cmts.User) (width 0.15) (tstamp 5F809435)) + (gr_line (start 217.45 82.7895) (end 217.45 87.2895) (layer Cmts.User) (width 0.15) (tstamp 5F8093B7)) + (gr_line (start 213.95 82.7895) (end 217.45 82.7895) (layer Cmts.User) (width 0.15) (tstamp 5F8093F3)) + (gr_line (start 198.45 68.05) (end 194.95 68.05) (layer Cmts.User) (width 0.15) (tstamp 5F8093E1)) + (gr_line (start 194.95 68.05) (end 194.95 63.55) (layer Cmts.User) (width 0.15) (tstamp 5F809429)) + (gr_line (start 198.45 63.55) (end 198.45 68.05) (layer Cmts.User) (width 0.15) (tstamp 5F8093FC)) + (gr_line (start 194.95 63.55) (end 198.45 63.55) (layer Cmts.User) (width 0.15) (tstamp 5F8093ED)) + (gr_line (start 217.45 68.026) (end 213.95 68.026) (layer Cmts.User) (width 0.15) (tstamp 5F80942F)) + (gr_line (start 213.95 68.026) (end 213.95 63.526) (layer Cmts.User) (width 0.15) (tstamp 5F809417)) + (gr_line (start 217.45 63.526) (end 217.45 68.026) (layer Cmts.User) (width 0.15) (tstamp 5F80941D)) + (gr_line (start 213.95 63.526) (end 217.45 63.526) (layer Cmts.User) (width 0.15) (tstamp 5F8093C6)) + (gr_line (start 217.45 49.1514) (end 213.95 49.1514) (layer Cmts.User) (width 0.15) (tstamp 5F809426)) + (gr_line (start 213.95 49.1514) (end 213.95 44.6514) (layer Cmts.User) (width 0.15) (tstamp 5F8093EA)) + (gr_line (start 217.45 44.6514) (end 217.45 49.1514) (layer Cmts.User) (width 0.15) (tstamp 5F809414)) + (gr_line (start 213.95 44.6514) (end 217.45 44.6514) (layer Cmts.User) (width 0.15) (tstamp 5F809408)) + (gr_line (start 198.45 49.15) (end 194.95 49.15) (layer Cmts.User) (width 0.15) (tstamp 5F8093FF)) + (gr_line (start 194.95 49.15) (end 194.95 44.65) (layer Cmts.User) (width 0.15) (tstamp 5F8093DE)) + (gr_line (start 198.45 44.65) (end 198.45 49.15) (layer Cmts.User) (width 0.15) (tstamp 5F809411)) + (gr_line (start 194.95 44.65) (end 198.45 44.65) (layer Cmts.User) (width 0.15) (tstamp 5F80941A)) + (gr_line (start 179.35 44.35) (end 175.85 44.35) (layer Cmts.User) (width 0.15) (tstamp 5F8093C3)) + (gr_line (start 175.85 44.35) (end 175.85 39.85) (layer Cmts.User) (width 0.15) (tstamp 5F809423)) + (gr_line (start 179.35 39.85) (end 179.35 44.35) (layer Cmts.User) (width 0.15) (tstamp 5F80940E)) + (gr_line (start 175.85 39.85) (end 179.35 39.85) (layer Cmts.User) (width 0.15) (tstamp 5F8093C0)) + (gr_line (start 156.85 41.7308) (end 156.85 37.2308) (layer Cmts.User) (width 0.15) (tstamp 5F8093C9)) + (gr_line (start 160.35 41.7308) (end 156.85 41.7308) (layer Cmts.User) (width 0.15) (tstamp 5F8093F0)) + (gr_line (start 160.35 37.2308) (end 160.35 41.7308) (layer Cmts.User) (width 0.15) (tstamp 5F8093DB)) + (gr_line (start 156.85 37.2308) (end 160.35 37.2308) (layer Cmts.User) (width 0.15) (tstamp 5F809438)) + (gr_line (start 141.25 39.7484) (end 141.25 44.2484) (layer Cmts.User) (width 0.15) (tstamp 5F809432)) + (gr_line (start 137.75 39.7484) (end 141.25 39.7484) (layer Cmts.User) (width 0.15) (tstamp 5F8093D8)) + (gr_line (start 137.75 44.2484) (end 137.75 39.7484) (layer Cmts.User) (width 0.15) (tstamp 5F809405)) + (gr_line (start 141.25 44.2484) (end 137.75 44.2484) (layer Cmts.User) (width 0.15) (tstamp 5F8093F9)) + (gr_line (start 118.75 46.75) (end 118.75 42.25) (layer Cmts.User) (width 0.15) (tstamp 5F8093E7)) + (gr_line (start 122.25 46.75) (end 118.75 46.75) (layer Cmts.User) (width 0.15) (tstamp 5F8093BD)) + (gr_line (start 122.25 42.25) (end 122.25 46.75) (layer Cmts.User) (width 0.15) (tstamp 5F8093E4)) + (gr_line (start 118.75 42.25) (end 122.25 42.25) (layer Cmts.User) (width 0.15) (tstamp 5F8093D5)) + (gr_circle (center 100.01 104.49) (end 109.96 103.16) (layer Eco1.User) (width 0.15)) + (gr_line (start 225.026621 43.6956) (end 225.168321 43.835582) (layer Cmts.User) (width 0.1) (tstamp 5F8093BA)) + (gr_line (start 149 35) (end 170.95 35) (layer Cmts.User) (width 0.1) (tstamp 5F8093D2)) + (gr_line (start 88.977436 37.415945) (end 89.19368 37.348815) (layer Cmts.User) (width 0.1) (tstamp 5F8093CF)) + (gr_line (start 89.19368 37.348815) (end 89.425853 37.325405) (layer Cmts.User) (width 0.1) (tstamp 5F8093CC)) + (gr_line (start 138.154128 134) (end 93.9 146.75) (layer Cmts.User) (width 0.1) (tstamp 5F8093B4)) + (gr_line (start 88.275257 114.4) (end 88.273857 38.477435) (layer Cmts.User) (width 0.1) (tstamp 5F809420)) + (gr_line (start 225.168321 43.835582) (end 225.283881 43.997807) (layer Cmts.User) (width 0.1) (tstamp 5F80940B)) + (gr_line (start 224.861871 43.581466) (end 225.026621 43.6956) (layer Cmts.User) (width 0.1) (tstamp 5F809402)) + (gr_line (start 88.781752 37.52216) (end 88.977436 37.415945) (layer Cmts.User) (width 0.1) (tstamp 5F8094D7)) + (gr_line (start 225.370281 44.178672) (end 225.424381 44.374571) (layer Cmts.User) (width 0.1) (tstamp 5F8094D4)) + (gr_line (start 88.273857 38.477435) (end 88.297257 38.245261) (layer Cmts.User) (width 0.1) (tstamp 5F8094CB)) + (gr_line (start 170.95 35) (end 224.475441 43.445146) (layer Cmts.User) (width 0.1) (tstamp 5F8094E6)) + (gr_line (start 88.297257 38.245261) (end 88.364377 38.029014) (layer Cmts.User) (width 0.1) (tstamp 5F8094E3)) + (gr_line (start 92.55 146.2) (end 82.3 128.4) (layer Cmts.User) (width 0.1) (tstamp 5F8094E9)) + (gr_line (start 225.424381 44.374571) (end 225.443181 44.581902) (layer Cmts.User) (width 0.1) (tstamp 5F8094DA)) + (gr_line (start 224.677111 43.496776) (end 224.861871 43.581466) (layer Cmts.User) (width 0.1) (tstamp 5F8094C8)) + (gr_line (start 88.47059 37.833327) (end 88.611259 37.662831) (layer Cmts.User) (width 0.1) (tstamp 5F8094C2)) + (gr_line (start 224.475441 43.445146) (end 224.677111 43.496776) (layer Cmts.User) (width 0.1) (tstamp 5F8094C5)) + (gr_line (start 225.283881 43.997807) (end 225.370281 44.178672) (layer Cmts.User) (width 0.1) (tstamp 5F8094EC)) + (gr_line (start 225.443181 44.581902) (end 225.470181 119.5) (layer Cmts.User) (width 0.1) (tstamp 5F8094E0)) + (gr_line (start 88.364377 38.029014) (end 88.47059 37.833327) (layer Cmts.User) (width 0.1) (tstamp 5F8094CE)) + (gr_line (start 88.611259 37.662831) (end 88.781752 37.52216) (layer Cmts.User) (width 0.1) (tstamp 5F8094DD)) + (gr_line (start 82.2 126.4) (end 88 115.65) (layer Cmts.User) (width 0.1) (tstamp 5F8094D1)) + (gr_line (start 49.676679 -38.227998) (end 49.676679 -38.227998) (layer Cmts.User) (width 0.1)) + (gr_line (start 45.503294 -44.952764) (end 45.503294 -44.952764) (layer Eco2.User) (width 0.1)) + + (segment (start 112.55 53.28) (end 113.25 52.58) (width 0.25) (layer F.Cu) (net 1) (tstamp 5F754BC1)) + (via (at 128.75 46.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 1)) + (segment (start 128.75 47.675) (end 128.75 46.4) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 128.75 46.4) (end 128.75 47.675) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 127.5 49.025) (end 128.75 47.775) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 127.5 52.58) (end 127.5 49.025) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 127.5 49.05) (end 127.45 49) (width 0.25) (layer B.Cu) (net 1)) + (via (at 127.45 49) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 1)) + (segment (start 127.5 52.58) (end 127.5 49.05) (width 0.25) (layer B.Cu) (net 1)) + (segment (start 118.684987 48.300011) (end 119.359999 47.624999) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 119.359999 47.624999) (end 121.640001 47.624999) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 122.315013 48.300011) (end 126.750011 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 121.640001 47.624999) (end 122.315013 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 126.750011 48.300011) (end 127.45 49) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 115.167147 48.300011) (end 118.684987 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 113.5 49.967158) (end 115.167147 48.300011) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 113.5 52.58) (end 113.5 49.967158) (width 0.25) (layer F.Cu) (net 1)) + (segment (start 105.300001 67.100001) (end 105.300001 67.100001) (width 0.25) (layer F.Cu) (net 2) (tstamp 5BEDFB6F)) + (via (at 105.327833 67.072169) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 104.255686 66.000022) (end 105.127834 66.87217) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 94.8 67.14097) (end 95.940948 66.000022) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.127834 66.87217) (end 105.327833 67.072169) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 93.83 69.17) (end 94.8 68.2) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 94.8 68.2) (end 94.8 67.14097) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 92.18 69.17) (end 93.83 69.17) (width 0.25) (layer F.Cu) (net 2) (status 10)) + (segment (start 95.940948 66.000022) (end 104.255686 66.000022) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 106.2 69.8) (end 106.2 67.944336) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 106.77 70.37) (end 106.2 69.8) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 106.2 67.944336) (end 105.527832 67.272168) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 105.527832 67.272168) (end 105.327833 67.072169) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 108.77 70.37) (end 106.77 70.37) (width 0.25) (layer B.Cu) (net 2) (status 10)) + (segment (start 105.3 97) (end 106.25 97) (width 0.25) (layer F.Cu) (net 2)) + (via (at 106.25 97) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 105.225 97) (end 106.25 97) (width 0.25) (layer B.Cu) (net 2)) + (via (at 105.1894 122.6248) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (via (at 122.7738 119.02) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 106.25 97) (end 106.25 98.25) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 106.25 98.25) (end 110 102) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 110 119.2746) (end 108.6498 120.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 110 102) (end 110 119.2746) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.1894 122.6248) (end 105.1894 121.8106) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 106.3752 120.6248) (end 108.6498 120.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.1894 121.8106) (end 106.3752 120.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 124.03 119.02) (end 122.7738 119.02) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 122.7738 119.02) (end 124.03 119.02) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 119.0612) (end 122.7738 119.02) (width 0.25) (layer F.Cu) (net 2)) + (via (at 109.5123 119.7623) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 108.6498 120.6248) (end 109.5123 119.7623) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 108.325001 95.924999) (end 107.325001 95.924999) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.925002 86.247998) (end 109.925002 88.052002) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 107.325001 95.924999) (end 106.25 97) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.925002 88.052002) (end 109.75 88.227004) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.75 88.227004) (end 109.75 94.5) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 108.718815 70.365745) (end 109.750003 71.396933) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.750003 71.396933) (end 109.750003 86.072999) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.750003 86.072999) (end 109.925002 86.247998) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 109.75 94.5) (end 108.325001 95.924999) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 105.1894 122.6248) (end 100.8248 122.6248) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 100.8248 122.6248) (end 100.8 122.6) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 100.025 122.6) (end 99.025 123.6) (width 0.25) (layer F.Cu) (net 2)) + (via (at 100.2 122.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 99.2 123.6) (end 100.2 122.6) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 99.025 123.6) (end 99.2 123.6) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 100.8 122.6) (end 100.2 122.6) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 100.2 122.6) (end 100.025 122.6) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 121.02) (end 122.7326 120.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 120.7326) (end 122.7326 119.0612) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.8652 121.6) (end 122.7326 121.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 123.3326) (end 122.7326 121.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 121.7326) (end 122.7326 120.7326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 124 121.6) (end 122.8652 121.6) (width 0.25) (layer F.Cu) (net 2)) + (via (at 122.7326 121.7326) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 124 121.6) (end 122.8652 121.6) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 122.8652 121.6) (end 122.7326 121.7326) (width 0.25) (layer B.Cu) (net 2)) + (via (at 122.7326 123.3326) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 2)) + (segment (start 122.7326 123.9326) (end 122.7326 123.3326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 124 124.2) (end 123 124.2) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 123 124.2) (end 122.7326 123.9326) (width 0.25) (layer F.Cu) (net 2)) + (segment (start 122.7326 123.9326) (end 122.7326 123.3326) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 124 124.2) (end 123 124.2) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 123 124.2) (end 122.7326 123.9326) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 111.0746 118.2) (end 109.5123 119.7623) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 122.7738 119.02) (end 121.9538 118.2) (width 0.25) (layer B.Cu) (net 2)) + (segment (start 121.9538 118.2) (end 111.0746 118.2) (width 0.25) (layer B.Cu) (net 2)) + (via (at 131 46.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 3)) + (segment (start 131 47.425) (end 131 46.15) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 131 46.15) (end 131 47.425) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 131 48.58) (end 132.5 50.08) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 131 47.5555) (end 131 48.58) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 146.5 50.13) (end 146.5 53.45) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 132.5 51.364014) (end 136.388497 55.252511) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 146.5 53.45) (end 144.49749 55.45251) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 144.49749 55.45251) (end 136.588496 55.45251) (width 0.25) (layer B.Cu) (net 3)) + (segment (start 136.388497 55.252511) (end 136.588496 55.45251) (width 0.25) (layer F.Cu) (net 3)) + (via (at 136.588496 55.45251) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 3)) + (segment (start 132.5 50.13) (end 132.5 51.364014) (width 0.25) (layer F.Cu) (net 3)) + (segment (start 165.25 47.87) (end 165.25 52.19) (width 0.25) (layer B.Cu) (net 4) (tstamp 5F754BBC)) + (segment (start 150.55 49.64) (end 150.55 48.57) (width 0.25) (layer F.Cu) (net 4) (tstamp 5F754BBD)) + (segment (start 150.55 48.57) (end 151.25 47.87) (width 0.25) (layer F.Cu) (net 4) (tstamp 5F754BC1)) + (via (at 150.55 49.64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 4) (tstamp 5F754BC7)) + (segment (start 151.6 47.58) (end 151.6 45.915) (width 0.25) (layer F.Cu) (net 4)) + (via (at 151.3625 45.6775) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 4)) + (segment (start 150.5 44.815) (end 151.3625 45.6775) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 151.6 45.915) (end 151.3625 45.6775) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 151.3625 45.6775) (end 150.5 44.815) (width 0.25) (layer B.Cu) (net 4)) + (via (at 165.25 52.19) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 4)) + (segment (start 165.25 54.54) (end 165.25 52.19) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 164.3 55.49) (end 165.25 54.54) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 154.424812 55.49) (end 164.3 55.49) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 150.55 49.64) (end 150.55 51.615188) (width 0.25) (layer F.Cu) (net 4)) + (segment (start 150.55 51.615188) (end 154.424812 55.49) (width 0.25) (layer F.Cu) (net 4)) + (via (at 105.7 59) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 92.18 59.01) (end 105.69 59.01) (width 0.25) (layer F.Cu) (net 5) (status 10)) + (segment (start 105.69 59.01) (end 105.7 59) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 106.91 60.21) (end 105.899999 59.199999) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 105.899999 59.199999) (end 105.7 59) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 108.77 60.21) (end 106.91 60.21) (width 0.25) (layer B.Cu) (net 5) (status 10)) + (via (at 188 49.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 188 48.475) (end 188 49.75) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 188 49.75) (end 188 48.475) (width 0.25) (layer B.Cu) (net 5)) + (via (at 169.25 45.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 169.25 43.875) (end 169.25 45.15) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 169.25 45.15) (end 169.25 43.875) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 184.749999 45.224999) (end 188 48.475) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130.75 44.125) (end 131 43.875) (width 0.25) (layer F.Cu) (net 5)) + (via (at 130 43.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 129.975 43.875) (end 130 43.9) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 131 43.875) (end 129.975 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 169.109999 43.734999) (end 169.25 43.875) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130.975 43.9) (end 131 43.875) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130 43.9) (end 130.975 43.9) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 128.975 43.9) (end 128.75 44.125) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 130 43.9) (end 128.975 43.9) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 207.75 48.25) (end 206.75 48.25) (width 0.25) (layer B.Cu) (net 5)) + (via (at 206.75 48.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 207.75 48.25) (end 206.75 48.25) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 129.975 43.975) (end 127.375 43.975) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 127.375 43.975) (end 126.75 44.6) (width 0.25) (layer B.Cu) (net 5)) + (via (at 126.75 44.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (via (at 137.45 45.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 206.5 48.5) (end 206.75 48.25) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 123.55 47.8) (end 126.75 44.6) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 119.173599 47.174988) (end 121.826401 47.174988) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 118.548588 47.8) (end 119.173599 47.174988) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 110.457443 60.205745) (end 111.9 58.763188) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 121.826401 47.174988) (end 122.451412 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 114.922998 47.8) (end 118.548588 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 108.718815 60.205745) (end 110.457443 60.205745) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 111.9 58.763188) (end 111.9 50.822998) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 122.451412 47.8) (end 123.55 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 111.9 50.822998) (end 114.922998 47.8) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.15 43.75) (end 169.25 43.65) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 132.188589 43.875) (end 131 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 132.323113 43.875) (end 132.188589 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 137.45 45.6) (end 134.048113 45.6) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 134.048113 45.6) (end 132.323113 43.875) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 204.646 50) (end 204.6588 50.0128) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 188 49.75) (end 188.25 50) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 188.25 50) (end 204.646 50) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 205 50) (end 206.5 48.5) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 204.646 50) (end 205 50) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.892499 42.624999) (end 153.534999 42.624999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 159.740001 47.375001) (end 161.544 45.571002) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 153.534999 42.624999) (end 156 45.09) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 156 45.09) (end 156 45.915002) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 157.459999 47.375001) (end 159.740001 47.375001) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 41.265) (end 150.5 42.2325) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 42.2325) (end 150.892499 42.624999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 156 45.915002) (end 157.459999 47.375001) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 161.544 45.571002) (end 161.544 44.5262) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.1356 43.5356) (end 169.25 43.65) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 161.544 44.5262) (end 162.5346 43.5356) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 162.5346 43.5356) (end 169.1356 43.5356) (width 0.25) (layer F.Cu) (net 5)) + (via (at 150.500004 42.222496) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 5)) + (segment (start 150.5 42.222492) (end 150.500004 42.222496) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 138.049992 45.000008) (end 147.722492 45.000008) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 147.722492 45.000008) (end 150.500004 42.222496) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 41.265) (end 150.5 42.222492) (width 0.25) (layer B.Cu) (net 5)) + (segment (start 150.5 41.265) (end 150.5 42.222492) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 137.45 45.6) (end 138.049992 45.000008) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 150.5 42.222492) (end 150.500004 42.222496) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 173.852004 45.124999) (end 184.749999 45.124999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 173.380763 45.59624) (end 173.852004 45.124999) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.69624 45.59624) (end 173.380763 45.59624) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 169.25 45.15) (end 169.69624 45.59624) (width 0.25) (layer F.Cu) (net 5)) + (segment (start 184.6 54.4) (end 183.624999 55.375001) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBB)) + (segment (start 184.6 50.08) (end 184.6 54.4) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBC)) + (segment (start 169.9 51.85) (end 169.9 50.78) (width 0.25) (layer F.Cu) (net 6) (tstamp 5F754BBD)) + (segment (start 183.624999 55.375001) (end 170.624999 55.375001) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBE)) + (segment (start 170.624999 55.375001) (end 169.9 54.650002) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BBF)) + (segment (start 169.9 54.650002) (end 169.9 51.85) (width 0.25) (layer B.Cu) (net 6) (tstamp 5F754BC0)) + (segment (start 169.9 50.78) (end 170.6 50.08) (width 0.25) (layer F.Cu) (net 6) (tstamp 5F754BC1)) + (via (at 169.9 51.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 6) (tstamp 5F754BC7)) + (segment (start 169.25 48.73) (end 170.6 50.08) (width 0.25) (layer F.Cu) (net 6)) + (segment (start 169.25 47.425) (end 169.25 48.73) (width 0.25) (layer F.Cu) (net 6)) + (via (at 169.25 46.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 6)) + (segment (start 169.25 47.425) (end 169.25 46.15) (width 0.25) (layer F.Cu) (net 6)) + (segment (start 169.25 46.15) (end 169.25 47.425) (width 0.25) (layer B.Cu) (net 6)) + (segment (start 92.23 61.45) (end 105.25 61.45) (width 0.25) (layer F.Cu) (net 7) (status 10)) + (segment (start 105.25 61.45) (end 105.500001 61.700001) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 105.500001 61.700001) (end 105.7 61.9) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 106.55 62.75) (end 105.899999 62.099999) (width 0.25) (layer B.Cu) (net 7)) + (via (at 105.7 61.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 105.899999 62.099999) (end 105.7 61.9) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 108.77 62.75) (end 106.55 62.75) (width 0.25) (layer B.Cu) (net 7) (status 10)) + (segment (start 150.25 59.29) (end 151.25 59.29) (width 0.25) (layer B.Cu) (net 7)) + (via (at 151.5 59.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 151.25 59.29) (end 151.5 59.54) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 150.25 59.29) (end 151.25 59.29) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 151.25 59.29) (end 151.5 59.54) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 183.724999 64.124999) (end 184.5 64.9) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 184.5 65) (end 188.25 65) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 171.725 61.875) (end 173.974999 64.124999) (width 0.25) (layer F.Cu) (net 7)) + (via (at 170.775 61.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 169.5 61.875) (end 170.775 61.875) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 169.5 61.875) (end 170.775 61.875) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 170.775 61.875) (end 171.725 61.875) (width 0.25) (layer F.Cu) (net 7)) + (via (at 146.5326 61.0616) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 188.25 65) (end 189.5 65) (width 0.25) (layer B.Cu) (net 7)) + (via (at 189.5 65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 188.25 65) (end 189.5 65) (width 0.25) (layer F.Cu) (net 7)) + (via (at 206.5 65.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 207.75 65.5) (end 206.5 65.5) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 207.75 65.5) (end 206.5 65.5) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 206.5 65.5) (end 206.25 65.5) (width 0.25) (layer B.Cu) (net 7)) + (via (at 189.5 67.55) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 189.5 67.55) (end 189.5 65) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 108.718815 62.745745) (end 111.520735 62.745745) (width 0.25) (layer F.Cu) (net 7)) + (via (at 111.57499 62.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 111.520735 62.745745) (end 111.57499 62.8) (width 0.25) (layer F.Cu) (net 7)) + (via (at 200.65 68.35) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 153.428 61.468) (end 151.5 59.54) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 169.5 61.875) (end 169.093 61.468) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 169.093 61.468) (end 153.428 61.468) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 183.724999 64.124999) (end 173.974999 64.124999) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 146.2384 61.0616) (end 146.5326 61.0616) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 133.422 63.75) (end 133.722 64.05) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 133.722 64.05) (end 143.25 64.05) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 143.25 64.05) (end 146.2384 61.0616) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 147 60.5942) (end 146.5326 61.0616) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 147 60.2894) (end 147 60.5942) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 150.25 59.29) (end 147.9994 59.29) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 147.9994 59.29) (end 147 60.2894) (width 0.25) (layer F.Cu) (net 7)) + (via (at 202.565 67.31) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 201.525 68.35) (end 202.565 67.31) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 206.5 65.5) (end 204.375 65.5) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 204.375 65.5) (end 202.565 67.31) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 200.65 68.35) (end 201.525 68.35) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 200.525012 68.474988) (end 200.65 68.35) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 189.5 67.55) (end 190.424988 68.474988) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 190.424988 68.474988) (end 200.525012 68.474988) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 129.8 62.025) (end 129.8 62.4) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 129.8 62.4) (end 128.239998 62.4) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 127.839998 62) (end 128.239998 62.4) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 126.8 62) (end 127.839998 62) (width 0.25) (layer B.Cu) (net 7)) + (via (at 128.239998 62.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 7)) + (segment (start 126.8 62) (end 127.839998 62) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 127.839998 62) (end 128.239998 62.4) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 129.425 62.4) (end 129.8 62.025) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 128.239998 62.4) (end 129.425 62.4) (width 0.25) (layer F.Cu) (net 7)) + (segment (start 115.499989 66.724999) (end 111.57499 62.8) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 121.915002 67) (end 121.640001 66.724999) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 121.640001 66.724999) (end 115.499989 66.724999) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 128.239998 62.4) (end 123.639998 67) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 123.639998 67) (end 121.915002 67) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 133.422 63.75) (end 132.55 63.75) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 130.825 62.025) (end 129.8 62.025) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 132.55 63.75) (end 130.825 62.025) (width 0.25) (layer B.Cu) (net 7)) + (segment (start 188.8 55.78) (end 189.5 55.08) (width 0.25) (layer F.Cu) (net 8) (tstamp 5F754BC1)) + (via (at 188 50.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 8)) + (segment (start 188 52.025) (end 188 50.75) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 188 50.75) (end 188 52.025) (width 0.25) (layer B.Cu) (net 8)) + (segment (start 188.75 55.93) (end 189.7 54.98) (width 0.25) (layer F.Cu) (net 8)) + (via (at 203.8 53.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 8)) + (segment (start 203.8 54.88) (end 203.7 54.98) (width 0.25) (layer B.Cu) (net 8)) + (segment (start 203.8 53.2) (end 203.8 54.88) (width 0.25) (layer B.Cu) (net 8)) + (segment (start 189.7 54.98) (end 189.7 52) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 188.025 52) (end 188 52.025) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 189.7 52) (end 188.025 52) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 203.8 52.532998) (end 203.8 53.2) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 200.858501 50.791499) (end 202.058501 50.791499) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 202.058501 50.791499) (end 203.8 52.532998) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 192.449978 50.9) (end 193.766001 52.216023) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 193.766001 52.216023) (end 193.766001 52.981003) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 189.7 52) (end 190.8 50.9) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 190.8 50.9) (end 192.449978 50.9) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 193.766001 52.981003) (end 195.559999 54.775001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 198.074999 54.775001) (end 200.024999 52.825001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 195.559999 54.775001) (end 198.074999 54.775001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 200.024999 51.625001) (end 200.858501 50.791499) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 200.024999 52.825001) (end 200.024999 51.625001) (width 0.25) (layer F.Cu) (net 8)) + (segment (start 93.905755 64.09) (end 93.995755 64) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 92.18 64.09) (end 93.905755 64.09) (width 0.25) (layer F.Cu) (net 9) (status 10)) + (segment (start 93.995755 64) (end 105.417158 64) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 106.985745 65.285745) (end 105.899999 64.199999) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 105.417158 64) (end 105.7 64) (width 0.25) (layer F.Cu) (net 9)) + (via (at 105.7 64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 108.718815 65.285745) (end 106.985745 65.285745) (width 0.25) (layer B.Cu) (net 9) (status 10)) + (segment (start 105.899999 64.199999) (end 105.7 64) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 131.25 81.9) (end 128.75 81.9) (width 0.25) (layer F.Cu) (net 9)) + (via (at 149.75 80.94) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 149.75 79.69) (end 149.75 80.94) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 149.75 80.94) (end 149.75 79.69) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 188.5 87) (end 188.5 88.25) (width 0.25) (layer B.Cu) (net 9)) + (via (at 188.5 88.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 188.5 87) (end 188.5 88.25) (width 0.25) (layer F.Cu) (net 9)) + (via (at 113.25 77.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (via (at 147.500012 82.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (via (at 206.825 84.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 207.75 84.5) (end 206.825 84.5) (width 0.25) (layer B.Cu) (net 9)) + (via (at 130 81.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 131.25 81.9) (end 130 81.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 128.5 81.9) (end 130 81.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 109.908328 66.475258) (end 109.908328 69.310086) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 108.718815 65.285745) (end 109.908328 66.475258) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 109.908328 69.310086) (end 112.000022 71.40178) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 112.000022 71.40178) (end 112.000022 76.500022) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 112.000022 76.500022) (end 113.050001 77.550001) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 113.050001 77.550001) (end 113.25 77.75) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 146.750012 82.8) (end 147.500012 82.05) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 131.25 81.9) (end 132.25 82.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 132.25 82.8) (end 146.750012 82.8) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 173.25 82.9) (end 172 81.65) (width 0.25) (layer B.Cu) (net 9)) + (via (at 170.48 81.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 169.725 81.65) (end 170.48 81.65) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 172 81.65) (end 170.48 81.65) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 170.48 81.65) (end 169.725 81.65) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 127.489 81.839) (end 128.408 81.839) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 113.25 77.75) (end 123.4 77.75) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 128.408 81.839) (end 128.5 81.931) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 123.4 77.75) (end 127.489 81.839) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 207.75 84.5) (end 206.825 84.5) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 148.610012 80.94) (end 147.500012 82.05) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 149.75 80.94) (end 148.610012 80.94) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 169.725 81.65) (end 166.8162 81.65) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 160.92342 81.01502) (end 160.92341 81.01501) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 166.8162 81.65) (end 166.18122 81.01502) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 166.18122 81.01502) (end 160.92342 81.01502) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 160.92342 81.01502) (end 159.946834 81.01502) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 159.288024 80.35621) (end 156.684311 80.35621) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 150.2748 80.3148) (end 149.75 79.79) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 159.946834 81.01502) (end 159.288024 80.35621) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 156.684311 80.35621) (end 156.642901 80.3148) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 156.642901 80.3148) (end 150.2748 80.3148) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 204.922996 84.5) (end 206.825 84.5) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 202.618496 86.8045) (end 204.922996 84.5) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 189.003 87.503) (end 194.637301 87.503) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 199.461199 86.8045) (end 202.618496 86.8045) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 188.5 87) (end 189.003 87.503) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 194.637301 87.503) (end 194.784311 87.65001) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 194.784311 87.65001) (end 198.615689 87.65001) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 198.615689 87.65001) (end 199.461199 86.8045) (width 0.25) (layer F.Cu) (net 9)) + (segment (start 176.45 82.9) (end 176.1292 82.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 176.1292 82.9) (end 173.25 82.9) (width 0.25) (layer B.Cu) (net 9)) + (via (at 184.15 82.9056) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 184.1444 82.9) (end 184.15 82.9056) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 176.45 82.9) (end 184.1444 82.9) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 184.15 82.9056) (end 186.0296 82.9056) (width 0.25) (layer F.Cu) (net 9)) + (via (at 186.0296 82.9056) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 9)) + (segment (start 188.5 85.376) (end 188.5 87) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 186.0296 82.9056) (end 188.5 85.376) (width 0.25) (layer B.Cu) (net 9)) + (segment (start 208 55.68) (end 208.7 54.98) (width 0.25) (layer F.Cu) (net 10) (tstamp 5F754BC1)) + (segment (start 209 54.68) (end 208.7 54.98) (width 0.25) (layer F.Cu) (net 10)) + (via (at 207.75 53) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 10)) + (segment (start 207.75 51.8) (end 207.75 53) (width 0.25) (layer B.Cu) (net 10)) + (segment (start 207.75 53) (end 207.75 51.8) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 220.70879 60.29121) (end 214.6554 60.29121) (width 0.25) (layer B.Cu) (net 10)) + (via (at 214.6554 60.29121) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 10)) + (segment (start 222.7 58.3) (end 220.70879 60.29121) (width 0.25) (layer B.Cu) (net 10)) + (segment (start 222.7 54.98) (end 222.7 58.3) (width 0.25) (layer B.Cu) (net 10)) + (segment (start 212.79281 60.29121) (end 214.6554 60.29121) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 208.7 54.98) (end 208.7 56.1984) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 208.7 56.1984) (end 212.79281 60.29121) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 207.75 54.03) (end 207.75 53) (width 0.25) (layer F.Cu) (net 10)) + (segment (start 208.7 54.98) (end 207.75 54.03) (width 0.25) (layer F.Cu) (net 10)) + (via (at 105.6 65.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 105.5 65.1) (end 105.6 65.2) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 95.5 65.1) (end 105.5 65.1) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 93.97 66.63) (end 95.5 65.1) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 92.18 66.63) (end 93.97 66.63) (width 0.25) (layer F.Cu) (net 11) (status 10)) + (segment (start 106.887507 67.83) (end 106.2 67.142493) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 106.2 67.142493) (end 106.2 65.8) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 106.2 65.8) (end 105.799999 65.399999) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 105.799999 65.399999) (end 105.6 65.2) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 108.77 67.83) (end 106.887507 67.83) (width 0.25) (layer B.Cu) (net 11) (status 10)) + (via (at 112 102.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 112 100.975) (end 112 102.25) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 112 102.25) (end 112 100.975) (width 0.25) (layer B.Cu) (net 11)) + (via (at 150 97.94) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 150 96.69) (end 150 97.94) (width 0.25) (layer F.Cu) (net 11)) + (via (at 111.350001 97.825012) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 112 100.975) (end 112 98.475011) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112 98.475011) (end 111.350001 97.825012) (width 0.25) (layer B.Cu) (net 11)) + (via (at 189.3875 105.8625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 188.5 104.975) (end 189.3875 105.8625) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 189.3875 105.8625) (end 188.5 104.975) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 169.25 94.15) (end 182.5 94.15) (width 0.25) (layer B.Cu) (net 11)) + (via (at 169.25 98.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 169.25 100.375) (end 169.25 98.9) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 169.25 100.375) (end 169.25 98.9) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 169.25 98.9) (end 169.25 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 183 94.15) (end 183.25 94.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 182.5 94.15) (end 183 94.15) (width 0.25) (layer B.Cu) (net 11)) + (via (at 186 94.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 183.25 94.4) (end 186 94.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 188.5 97) (end 188.5 104.975) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 186 94.5) (end 188.5 97) (width 0.25) (layer F.Cu) (net 11)) + (via (at 129.75 101.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 131 101.4) (end 129.75 101.4) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 129.392998 101.4) (end 129.75 101.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 129.75 101.4) (end 131 101.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 164.249977 92.289977) (end 166.110001 94.150001) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 150 97.94) (end 150 94.1708) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 155.147998 92.289977) (end 164.249977 92.289977) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 149.987 94.1578) (end 151.2316 92.9132) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 166.110001 94.150001) (end 169.249999 94.150001) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 151.2316 92.9132) (end 154.524775 92.9132) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 169.249999 94.150001) (end 169.25 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 150 94.1708) (end 149.987 94.1578) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 154.524775 92.9132) (end 155.147998 92.289977) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 189.3875 105.8625) (end 190.17501 106.65001) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 190.17501 106.65001) (end 202.87601 106.65001) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 129.289998 101.397) (end 129.424 101.397) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 126.571998 98.679) (end 129.289998 101.397) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 114.071 98.679) (end 126.571998 98.679) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112 100.975) (end 112 100.75) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112 100.75) (end 114.071 98.679) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 131 101.4) (end 131.625 101.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 133.5 99.525) (end 133.5 96.3) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 131.625 101.4) (end 133.5 99.525) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 110.25 88.363415) (end 110.25 96.8) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 108.718815 68.815588) (end 110.25 70.346773) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.25 70.346773) (end 110.25 85.936585) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.375013 86.061598) (end 110.375013 88.238402) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.25 96.8) (end 111.275012 97.825012) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.375013 88.238402) (end 110.25 88.363415) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 110.25 85.936585) (end 110.375013 86.061598) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 108.718815 67.825745) (end 108.718815 68.815588) (width 0.25) (layer F.Cu) (net 11)) + (via (at 207.057999 103.273747) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 208.2 103.4) (end 207.184252 103.4) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 208.2 103.4) (end 207.184252 103.4) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 207.184252 103.4) (end 207.057999 103.273747) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 207.184252 103.4) (end 207.057999 103.273747) (width 0.25) (layer F.Cu) (net 11)) + (via (at 205.8 104) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 11)) + (segment (start 206.526253 103.273747) (end 207.057999 103.273747) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 205.8 104) (end 206.526253 103.273747) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 202.87601 106.65001) (end 203.14999 106.65001) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 204.6 105.2) (end 205.8 104) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 203.14999 106.65001) (end 204.6 105.2) (width 0.25) (layer F.Cu) (net 11)) + (segment (start 135.65 94.15) (end 135.2962 94.5038) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 133.5 96.3) (end 135.2962 94.5038) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 136.0248 94.15) (end 150 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 136.0248 94.15) (end 135.65 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 135.75 94.15) (end 136.0248 94.15) (width 0.25) (layer B.Cu) (net 11)) + (segment (start 112.75 72.58) (end 112.75 75.65) (width 0.25) (layer F.Cu) (net 12)) + (via (at 112.75 75.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 12)) + (segment (start 113.5 71.83) (end 112.75 72.58) (width 0.25) (layer F.Cu) (net 12)) + (segment (start 114.225001 77.125001) (end 112.75 75.65) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 125.824999 77.125001) (end 114.225001 77.125001) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 127.5 71.83) (end 127.5 75.45) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 127.5 75.45) (end 125.824999 77.125001) (width 0.25) (layer B.Cu) (net 12)) + (via (at 126.8 66.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 12)) + (segment (start 126.8 65.55) (end 126.8 66.6) (width 0.25) (layer F.Cu) (net 12)) + (segment (start 126.8 66.6) (end 126.8 65.55) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 127.5 67.3) (end 127.5 71.68) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 126.8 66.6) (end 127.5 67.3) (width 0.25) (layer B.Cu) (net 12)) + (segment (start 146.5 73.45) (end 145.524999 74.425001) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBB)) + (segment (start 146.5 69.13) (end 146.5 73.45) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBC)) + (segment (start 131.8 70.9) (end 131.8 69.83) (width 0.25) (layer F.Cu) (net 13) (tstamp 5F754BBD)) + (segment (start 145.524999 74.425001) (end 132.524999 74.425001) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBE)) + (segment (start 132.524999 74.425001) (end 131.8 73.700002) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BBF)) + (segment (start 131.8 73.700002) (end 131.8 70.9) (width 0.25) (layer B.Cu) (net 13) (tstamp 5F754BC0)) + (segment (start 131.8 69.83) (end 132.5 69.13) (width 0.25) (layer F.Cu) (net 13) (tstamp 5F754BC1)) + (via (at 131.8 70.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 13) (tstamp 5F754BC7)) + (via (at 131 65.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 13)) + (segment (start 129.8 65.575) (end 130.975 65.575) (width 0.25) (layer B.Cu) (net 13)) + (segment (start 130.975 65.575) (end 131 65.6) (width 0.25) (layer B.Cu) (net 13)) + (segment (start 129.825 65.6) (end 129.8 65.575) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 131 65.6) (end 129.825 65.6) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 131 65.6) (end 132.5 67.1) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 132.5 69.08) (end 132.5 67.1) (width 0.25) (layer F.Cu) (net 13)) + (segment (start 165.6 70.99) (end 164.624999 71.965001) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBB)) + (segment (start 165.6 66.67) (end 165.6 70.99) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBC)) + (segment (start 150.9 68.44) (end 150.9 67.37) (width 0.25) (layer F.Cu) (net 14) (tstamp 5F754BBD)) + (segment (start 164.624999 71.965001) (end 151.624999 71.965001) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBE)) + (segment (start 151.624999 71.965001) (end 150.9 71.240002) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BBF)) + (segment (start 150.9 71.240002) (end 150.9 68.44) (width 0.25) (layer B.Cu) (net 14) (tstamp 5F754BC0)) + (segment (start 150.9 67.37) (end 151.6 66.67) (width 0.25) (layer F.Cu) (net 14) (tstamp 5F754BC1)) + (via (at 150.9 68.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 14) (tstamp 5F754BC7)) + (segment (start 151.6 66.67) (end 151.6 65.89) (width 0.25) (layer F.Cu) (net 14)) + (segment (start 150.25 64.54) (end 150.25 62.84) (width 0.25) (layer F.Cu) (net 14)) + (segment (start 151.6 65.89) (end 150.25 64.54) (width 0.25) (layer F.Cu) (net 14)) + (via (at 150.25 61.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 14)) + (segment (start 150.25 62.84) (end 150.25 61.54) (width 0.25) (layer F.Cu) (net 14)) + (segment (start 150.25 61.54) (end 150.25 62.84) (width 0.25) (layer B.Cu) (net 14)) + (segment (start 184.6 73.4) (end 183.624999 74.375001) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBB)) + (segment (start 184.6 69.08) (end 184.6 73.4) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBC)) + (segment (start 169.9 70.85) (end 169.9 69.78) (width 0.25) (layer F.Cu) (net 15) (tstamp 5F754BBD)) + (segment (start 183.624999 74.375001) (end 170.624999 74.375001) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBE)) + (segment (start 170.624999 74.375001) (end 169.9 73.650002) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BBF)) + (segment (start 169.9 73.650002) (end 169.9 70.85) (width 0.25) (layer B.Cu) (net 15) (tstamp 5F754BC0)) + (segment (start 169.9 69.78) (end 170.6 69.08) (width 0.25) (layer F.Cu) (net 15) (tstamp 5F754BC1)) + (via (at 169.9 70.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 15) (tstamp 5F754BC7)) + (segment (start 170.6 69.08) (end 170.6 66.525) (width 0.25) (layer F.Cu) (net 15)) + (via (at 170.4875 66.4125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 15)) + (segment (start 169.5 65.425) (end 170.4875 66.4125) (width 0.25) (layer B.Cu) (net 15)) + (segment (start 170.6 66.525) (end 170.4875 66.4125) (width 0.25) (layer F.Cu) (net 15)) + (segment (start 170.4875 66.4125) (end 169.5 65.425) (width 0.25) (layer F.Cu) (net 15)) + (segment (start 189 74.58) (end 189.7 73.88) (width 0.25) (layer F.Cu) (net 16) (tstamp 5F754BC1)) + (segment (start 189.7 73.88) (end 189.7 69.8) (width 0.25) (layer F.Cu) (net 16)) + (via (at 204 71.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 16)) + (segment (start 204 73.58) (end 203.7 73.88) (width 0.25) (layer B.Cu) (net 16)) + (segment (start 204 71.75) (end 204 73.58) (width 0.25) (layer B.Cu) (net 16)) + (via (at 188.25 67.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 16)) + (segment (start 188.25 68.55) (end 188.25 67.5) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 188.25 67.5) (end 188.25 68.55) (width 0.25) (layer B.Cu) (net 16)) + (segment (start 189.7 69.8) (end 189.7 68.924999) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 189.325001 68.55) (end 189.7 68.924999) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 188.25 68.55) (end 189.325001 68.55) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 204 71.467158) (end 204 71.75) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 189.7 68.924999) (end 201.457841 68.924999) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 201.457841 68.924999) (end 204 71.467158) (width 0.25) (layer F.Cu) (net 16)) + (segment (start 223.5 73.08) (end 222.7 73.88) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 208.7 73.88) (end 208.7 72.2) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.7 72.2) (end 207.75 71.25) (width 0.25) (layer F.Cu) (net 17)) + (via (at 207.75 70.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 17)) + (segment (start 207.75 71.25) (end 207.75 70.5) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 207.75 69.05) (end 207.75 70.5) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 207.75 70.5) (end 207.75 69.05) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.75 74.08) (end 208.25 74.58) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 222.75 74.08) (end 222.75 77.45) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 208.7 73.88) (end 208.7 75.13) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.7 75.13) (end 211.322 77.752) (width 0.25) (layer F.Cu) (net 17)) + (via (at 216.027 79.074989) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 17)) + (segment (start 212.644989 79.074989) (end 216.027 79.074989) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 208.7 75.13) (end 212.644989 79.074989) (width 0.25) (layer F.Cu) (net 17)) + (segment (start 221.125011 79.074989) (end 222.75 77.45) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 216.027 79.074989) (end 221.125011 79.074989) (width 0.25) (layer B.Cu) (net 17)) + (segment (start 113.05 92.6) (end 113.05 91.53) (width 0.25) (layer F.Cu) (net 18) (tstamp 5F754BBD)) + (segment (start 113.05 91.53) (end 113.75 90.83) (width 0.25) (layer F.Cu) (net 18) (tstamp 5F754BC1)) + (via (at 113.05 92.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 18) (tstamp 5F754BC7)) + (segment (start 128.5 89.68) (end 127.5 90.68) (width 0.25) (layer B.Cu) (net 18)) + (via (at 128.5 86.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 18)) + (segment (start 128.5 85.7) (end 128.5 86.9) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 128.5 86.9) (end 128.5 89.58) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 128.5 85.7) (end 128.5 86.9) (width 0.25) (layer F.Cu) (net 18)) + (segment (start 113.05 94.254) (end 113.05 92.6) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 125.997999 96.125001) (end 114.921001 96.125001) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 127.75 90.83) (end 127.75 94.373) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 114.921001 96.125001) (end 113.05 94.254) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 127.75 94.373) (end 125.997999 96.125001) (width 0.25) (layer B.Cu) (net 18)) + (segment (start 131.55 89.9) (end 131.55 88.83) (width 0.25) (layer F.Cu) (net 19) (tstamp 5F754BBD)) + (segment (start 131.55 88.83) (end 132.25 88.13) (width 0.25) (layer F.Cu) (net 19) (tstamp 5F754BC1)) + (via (at 131.55 89.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 19) (tstamp 5F754BC7)) + (segment (start 131.25 86.93) (end 132.5 88.18) (width 0.25) (layer F.Cu) (net 19)) + (segment (start 131.25 85.45) (end 131.25 86.93) (width 0.25) (layer F.Cu) (net 19)) + (segment (start 131.25 89.7) (end 131.55 90) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 131.25 85.45) (end 131.25 89.7) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 146.25 88.13) (end 146.25 92.45) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 146.25 92.45) (end 145.650001 93.049999) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 145.650001 93.049999) (end 133.386409 93.049999) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 131.55 91.21359) (end 131.55 89.9) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 133.386409 93.049999) (end 131.55 91.21359) (width 0.25) (layer B.Cu) (net 19)) + (segment (start 150.8 87.64) (end 150.8 86.57) (width 0.25) (layer F.Cu) (net 20) (tstamp 5F754BBD)) + (segment (start 150.8 86.57) (end 151.5 85.87) (width 0.25) (layer F.Cu) (net 20) (tstamp 5F754BC1)) + (via (at 150.8 87.64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 20) (tstamp 5F754BC7)) + (segment (start 149.75 83.92) (end 151.6 85.77) (width 0.25) (layer F.Cu) (net 20)) + (segment (start 149.75 83.24) (end 149.75 83.82) (width 0.25) (layer F.Cu) (net 20)) + (segment (start 149.75 86.59) (end 150.8 87.64) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 149.75 83.24) (end 149.75 86.49) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 150.8 89.0145) (end 150.8 87.64) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 152.950501 91.165001) (end 150.8 89.0145) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 165.5 85.87) (end 165.5 90.19) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 164.524999 91.165001) (end 152.950501 91.165001) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 165.5 90.19) (end 164.524999 91.165001) (width 0.25) (layer B.Cu) (net 20)) + (segment (start 184.6 92.5) (end 183.624999 93.475001) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBB)) + (segment (start 184.6 88.18) (end 184.6 92.5) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBC)) + (segment (start 169.9 89.95) (end 169.9 88.88) (width 0.25) (layer F.Cu) (net 21) (tstamp 5F754BBD)) + (segment (start 183.624999 93.475001) (end 170.624999 93.475001) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBE)) + (segment (start 170.624999 93.475001) (end 169.9 92.750002) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BBF)) + (segment (start 169.9 92.750002) (end 169.9 89.95) (width 0.25) (layer B.Cu) (net 21) (tstamp 5F754BC0)) + (segment (start 169.9 88.88) (end 170.6 88.18) (width 0.25) (layer F.Cu) (net 21) (tstamp 5F754BC1)) + (via (at 169.9 89.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 21) (tstamp 5F754BC7)) + (segment (start 169.725 87.305) (end 170.6 88.18) (width 0.25) (layer F.Cu) (net 21)) + (segment (start 169.725 85.2) (end 169.725 87.305) (width 0.25) (layer F.Cu) (net 21)) + (via (at 169.75 86.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 21)) + (segment (start 169.725 85.2) (end 169.725 86.625) (width 0.25) (layer B.Cu) (net 21)) + (segment (start 169.725 86.625) (end 169.75 86.65) (width 0.25) (layer B.Cu) (net 21)) + (segment (start 188.5 91.88) (end 189.7 93.08) (width 0.25) (layer F.Cu) (net 22)) + (via (at 188.5 91.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 22)) + (segment (start 188.5 90.55) (end 188.5 91.75) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 188.5 91.75) (end 188.5 91.88) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 188.5 90.55) (end 188.5 91.75) (width 0.25) (layer B.Cu) (net 22)) + (via (at 201.797467 97.158879) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 22)) + (segment (start 203.7 95.256346) (end 201.797467 97.158879) (width 0.25) (layer B.Cu) (net 22)) + (segment (start 201.06537 98.6) (end 201.797467 97.867903) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 189.7 93.13) (end 189.7 94.5135) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 201.797467 97.867903) (end 201.797467 97.158879) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 193.7865 98.6) (end 201.06537 98.6) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 203.7 93.08) (end 203.7 95.256346) (width 0.25) (layer B.Cu) (net 22)) + (segment (start 189.75 93.08) (end 189.7 93.13) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 189.7 94.5135) (end 193.7865 98.6) (width 0.25) (layer F.Cu) (net 22)) + (segment (start 222.7 93.08) (end 222.83 93.08) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 222.83 93.08) (end 223.5 93.75) (width 0.25) (layer B.Cu) (net 23)) + (via (at 209.75 97.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 23)) + (segment (start 221.002001 98.275001) (end 210.525001 98.275001) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 210.525001 98.275001) (end 209.75 97.5) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 222.7 93.08) (end 222.7 96.577002) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 222.7 96.577002) (end 221.002001 98.275001) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 208.7 96.45) (end 208.7 93.08) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 209.75 97.5) (end 208.7 96.45) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 208.7 93.08) (end 208.7 91.7) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 208.7 91.7) (end 207.75 90.75) (width 0.25) (layer F.Cu) (net 23)) + (via (at 207.75 89.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 23)) + (segment (start 207.75 88.05) (end 207.75 89.25) (width 0.25) (layer B.Cu) (net 23)) + (segment (start 207.75 90.75) (end 207.75 89.25) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 207.75 89.25) (end 207.75 88.05) (width 0.25) (layer F.Cu) (net 23)) + (segment (start 127.5 114) (end 126.524999 114.975001) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBB)) + (segment (start 127.5 109.68) (end 127.5 114) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBC)) + (segment (start 112.8 111.45) (end 112.8 110.38) (width 0.25) (layer F.Cu) (net 24) (tstamp 5F754BBD)) + (segment (start 126.524999 114.975001) (end 113.524999 114.975001) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBE)) + (segment (start 113.524999 114.975001) (end 112.8 114.250002) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BBF)) + (segment (start 112.8 114.250002) (end 112.8 111.45) (width 0.25) (layer B.Cu) (net 24) (tstamp 5F754BC0)) + (segment (start 112.8 110.38) (end 113.5 109.68) (width 0.25) (layer F.Cu) (net 24) (tstamp 5F754BC1)) + (via (at 112.8 111.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 24) (tstamp 5F754BC7)) + (segment (start 112.8 105.325) (end 112 104.525) (width 0.25) (layer B.Cu) (net 24)) + (segment (start 112.8 111.45) (end 112.8 105.325) (width 0.25) (layer B.Cu) (net 24)) + (via (at 112 103.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 24)) + (segment (start 112 104.525) (end 112 103.25) (width 0.25) (layer B.Cu) (net 24)) + (segment (start 112 103.25) (end 112 104.525) (width 0.25) (layer F.Cu) (net 24)) + (segment (start 146.5 111.5) (end 145.524999 112.475001) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBB)) + (segment (start 146.5 107.18) (end 146.5 111.5) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBC)) + (segment (start 131.8 108.95) (end 131.8 107.88) (width 0.25) (layer F.Cu) (net 25) (tstamp 5F754BBD)) + (segment (start 145.524999 112.475001) (end 132.524999 112.475001) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBE)) + (segment (start 132.524999 112.475001) (end 131.8 111.750002) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BBF)) + (segment (start 131.8 111.750002) (end 131.8 108.95) (width 0.25) (layer B.Cu) (net 25) (tstamp 5F754BC0)) + (segment (start 131.8 107.88) (end 132.5 107.18) (width 0.25) (layer F.Cu) (net 25) (tstamp 5F754BC1)) + (via (at 131.8 108.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 25) (tstamp 5F754BC7)) + (segment (start 131.8 105.75) (end 131 104.95) (width 0.25) (layer B.Cu) (net 25)) + (segment (start 131.8 108.95) (end 131.8 105.65) (width 0.25) (layer B.Cu) (net 25)) + (segment (start 131 105.78) (end 132.5 107.28) (width 0.25) (layer F.Cu) (net 25)) + (segment (start 131 104.95) (end 131 105.78) (width 0.25) (layer F.Cu) (net 25)) + (segment (start 165.6 109.09) (end 164.624999 110.065001) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBB)) + (segment (start 165.6 104.77) (end 165.6 109.09) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBC)) + (segment (start 150.9 106.54) (end 150.9 105.47) (width 0.25) (layer F.Cu) (net 26) (tstamp 5F754BBD)) + (segment (start 164.624999 110.065001) (end 151.624999 110.065001) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBE)) + (segment (start 151.624999 110.065001) (end 150.9 109.340002) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BBF)) + (segment (start 150.9 109.340002) (end 150.9 106.54) (width 0.25) (layer B.Cu) (net 26) (tstamp 5F754BC0)) + (segment (start 150.9 105.47) (end 151.6 104.77) (width 0.25) (layer F.Cu) (net 26) (tstamp 5F754BC1)) + (via (at 150.9 106.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 26) (tstamp 5F754BC7)) + (segment (start 150.9 101.24) (end 150 100.34) (width 0.25) (layer B.Cu) (net 26)) + (segment (start 150.9 106.54) (end 150.9 101.24) (width 0.25) (layer B.Cu) (net 26)) + (segment (start 151.6 101.94) (end 150 100.34) (width 0.25) (layer F.Cu) (net 26)) + (segment (start 151.6 104.77) (end 151.6 101.94) (width 0.25) (layer F.Cu) (net 26)) + (segment (start 169.9 109.05) (end 169.9 107.98) (width 0.25) (layer F.Cu) (net 27) (tstamp 5F754BBD)) + (segment (start 169.9 107.98) (end 170.6 107.28) (width 0.25) (layer F.Cu) (net 27) (tstamp 5F754BC1)) + (via (at 169.9 109.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 27) (tstamp 5F754BC7)) + (segment (start 169.25 108.4) (end 169.9 109.05) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 169.25 103.925) (end 169.25 108.4) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 170.6 105.275) (end 169.25 103.925) (width 0.25) (layer F.Cu) (net 27)) + (segment (start 170.6 107.28) (end 170.6 105.275) (width 0.25) (layer F.Cu) (net 27)) + (segment (start 184.6 109.05) (end 181.5 112.15) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 169.9 110.522996) (end 169.9 109.05) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 181.5 112.15) (end 172.277004 112.15) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 172.252002 112.124998) (end 171.502002 112.124998) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 171.502002 112.124998) (end 169.9 110.522996) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 172.277004 112.15) (end 172.252002 112.124998) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 184.6 107.28) (end 184.6 109.05) (width 0.25) (layer B.Cu) (net 27)) + (segment (start 189 113.85) (end 189 112.78) (width 0.25) (layer F.Cu) (net 28) (tstamp 5F754BBD)) + (segment (start 189 112.78) (end 189.7 112.08) (width 0.25) (layer F.Cu) (net 28) (tstamp 5F754BC1)) + (via (at 189 113.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 28) (tstamp 5F754BC7)) + (segment (start 188.5 110.88) (end 189.7 112.08) (width 0.25) (layer F.Cu) (net 28)) + (segment (start 188.5 108.525) (end 188.5 110.88) (width 0.25) (layer F.Cu) (net 28)) + (segment (start 189 115.25) (end 189 113.85) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 191.784 118.034) (end 189 115.25) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 200.6725 118.034) (end 191.784 118.034) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 203.7 112.08) (end 203.7 115.0065) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 203.7 115.0065) (end 200.6725 118.034) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 188.5315 108.5565) (end 188.5 108.525) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 189 113.85) (end 188.5315 113.3815) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 188.5315 113.3815) (end 188.5315 108.5565) (width 0.25) (layer B.Cu) (net 28)) + (segment (start 208.05 113.85) (end 208.05 112.78) (width 0.25) (layer F.Cu) (net 29) (tstamp 5F754BBD)) + (segment (start 208.05 112.78) (end 208.75 112.08) (width 0.25) (layer F.Cu) (net 29) (tstamp 5F754BC1)) + (via (at 208.05 113.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 29) (tstamp 5F754BC7)) + (segment (start 223.6 111.23) (end 222.75 112.08) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 210.252002 117.02501) (end 209.465472 117.02501) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 222.75 115.25) (end 221 117) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 221 117) (end 210.277012 117) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 210.277012 117) (end 210.252002 117.02501) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208.05 115.609538) (end 208.05 113.85) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 222.75 112.08) (end 222.75 115.25) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 209.465472 117.02501) (end 208.05 115.609538) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208.2 106.95) (end 207.85 106.95) (width 0.25) (layer F.Cu) (net 29)) + (segment (start 207.85 106.95) (end 208 107.1) (width 0.25) (layer F.Cu) (net 29)) + (via (at 208 108.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 29)) + (segment (start 208 107.1) (end 208 108.6) (width 0.25) (layer F.Cu) (net 29)) + (segment (start 208 107.15) (end 208.2 106.95) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208 108.6) (end 208 107.15) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208 113.8) (end 208.05 113.85) (width 0.25) (layer B.Cu) (net 29)) + (segment (start 208 108.6) (end 208 113.8) (width 0.25) (layer B.Cu) (net 29)) + (via (at 98.687 139.889) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 30)) + (segment (start 97.975654 140.600346) (end 98.687 139.889) (width 0.25) (layer B.Cu) (net 30)) + (segment (start 97.975654 140.752178) (end 97.975654 140.600346) (width 0.25) (layer B.Cu) (net 30)) + (segment (start 95.44641 127.72559) (end 96.086 127.086) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 91.877886 127.72559) (end 95.44641 127.72559) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 90.975654 128.627822) (end 91.877886 127.72559) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 96.086 127.086) (end 96.914 127.086) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 96.914 127.086) (end 99 125) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 101.175 125) (end 102.575 123.6) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 99 125) (end 101.175 125) (width 0.25) (layer F.Cu) (net 30)) + (via (at 101.175 125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 30)) + (segment (start 102.575 123.6) (end 101.175 125) (width 0.25) (layer B.Cu) (net 30)) + (segment (start 99.047411 139.889) (end 98.687 139.889) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 95 136) (end 101 136) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 101 136) (end 101 137.936411) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 94.334999 135.334999) (end 95 136) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 94.334999 132.229999) (end 94.334999 135.334999) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 95.635001 127.536999) (end 95.635001 130.929997) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 95.635001 130.929997) (end 94.334999 132.229999) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 101 137.936411) (end 99.047411 139.889) (width 0.25) (layer F.Cu) (net 30)) + (segment (start 96.086 127.086) (end 95.635001 127.536999) (width 0.25) (layer F.Cu) (net 30)) + (via (at 122.75 135) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 31)) + (segment (start 125.029234 129.080355) (end 125.029234 132.720766) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 125.029234 132.720766) (end 122.75 135) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 114.591755 135.789305) (end 111.506272 132.703822) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 121.960695 135.789305) (end 114.591755 135.789305) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 122.75 135) (end 121.960695 135.789305) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.595198 120.6248) (end 112.1998 120.6248) (width 0.25) (layer F.Cu) (net 31)) + (via (at 110.984999 121.234999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 31)) + (segment (start 112.1998 120.6248) (end 111.595198 120.6248) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 111.595198 120.6248) (end 110.984999 121.234999) (width 0.25) (layer B.Cu) (net 31)) + (segment (start 110.984999 121.234999) (end 111.595198 120.6248) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.506272 132.703822) (end 111.506272 131.668546) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.506272 131.668546) (end 108.474998 128.637272) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.474998 124.952002) (end 108.074998 124.552002) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.074998 124.552002) (end 108.074998 123.828319) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 110.668318 121.234999) (end 110.984999 121.234999) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.474998 128.637272) (end 108.474998 124.952002) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.074998 123.828319) (end 110.668318 121.234999) (width 0.25) (layer F.Cu) (net 31)) + (via (at 141.108 131.259) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 32)) + (segment (start 142.771 131.259) (end 141.108 131.259) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 146.5 126.28) (end 146.5 127.53) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 146.5 127.53) (end 142.771 131.259) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 132.5 126.28) (end 132.4122 126.28) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 136.254401 131.284401) (end 132.5 127.53) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 141.108 131.259) (end 141.082599 131.284401) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 141.082599 131.284401) (end 136.254401 131.284401) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 132.5 127.53) (end 132.5 126.28) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 132.5 126.28) (end 131.955 126.28) (width 0.25) (layer F.Cu) (net 32)) + (via (at 129 124.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 32)) + (segment (start 127.55 124.2) (end 129 124.2) (width 0.25) (layer B.Cu) (net 32)) + (segment (start 129.875 124.2) (end 130.1375 124.4625) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 129 124.2) (end 129.875 124.2) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 131.955 126.28) (end 130.1375 124.4625) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 129 124.2) (end 127.55 124.2) (width 0.25) (layer F.Cu) (net 32)) + (segment (start 107.42 48.85) (end 106.224255 50.045745) (width 0.5) (layer F.Cu) (net 33) (status 10)) + (segment (start 93.42456 50.1) (end 93.478815 50.045745) (width 0.5) (layer F.Cu) (net 33) (status 30)) + (via (at 100.400008 68.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 100.399628 68.79962) (end 100.400008 68.8) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 99.2 68.79962) (end 100.399628 68.79962) (width 0.5) (layer B.Cu) (net 33) (status 10)) + (segment (start 100.400388 68.79962) (end 100.400008 68.8) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.4 50.045745) (end 93.478815 50.045745) (width 0.5) (layer F.Cu) (net 33) (status 20)) + (segment (start 106.224255 50.045745) (end 100.4 50.045745) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 98.09999 89.29999) (end 98.3 89.5) (width 0.5) (layer F.Cu) (net 33) (status 30)) + (segment (start 100.400008 50.045753) (end 100.4 50.045745) (width 0.5) (layer B.Cu) (net 33)) + (via (at 100.4 50.045745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 100.400008 68.8) (end 100.400008 50.045753) (width 0.5) (layer B.Cu) (net 33) (tstamp 5C028D9F)) + (segment (start 100.400008 68.8) (end 100.5 68.899992) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 97.477817 78.061965) (end 96.4871 78.061965) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 96.4871 78.061965) (end 95.499272 78.061965) (width 0.5) (layer F.Cu) (net 33) (status 20)) + (segment (start 100.400008 75.139774) (end 97.477817 78.061965) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.400008 68.8) (end 100.400008 75.139774) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 97.9 83.55) (end 98.3 83.55) (width 0.5) (layer B.Cu) (net 33) (status 30)) + (segment (start 95.499272 81.149272) (end 97.9 83.55) (width 0.5) (layer B.Cu) (net 33) (status 20)) + (segment (start 95.499272 78.061965) (end 95.499272 81.149272) (width 0.5) (layer B.Cu) (net 33) (status 10)) + (segment (start 98.09999 89.29999) (end 98.3 89.5) (width 0.5) (layer B.Cu) (net 33) (status 30)) + (segment (start 107.5 80.7) (end 107.9 81.1) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156 37.54) (end 156 38.425) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156 38.425) (end 156.2 38.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206.225 85.875) (end 206.175 85.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 85.925) (end 206.175 86.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 66.675) (end 206.175 67.175) (width 0.5) (layer B.Cu) (net 33)) + (via (at 211.625 104.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 211.625 104.875) (end 213.35 104.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 116 44.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 116.875 45.375) (end 118.1 45.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116 44.5) (end 116.875 45.375) (width 0.5) (layer B.Cu) (net 33)) + (via (at 110.25 48) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 109.416256 48.833744) (end 110.25 48) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 107.42 48.85) (end 107.436256 48.833744) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 107.436256 48.833744) (end 109.416256 48.833744) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 113.75 44.5) (end 116 44.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.2 38.625) (end 155.665 38.625) (width 0.5) (layer F.Cu) (net 33)) + (via (at 193.0125 44.7375) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 153.75 96.29) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 153.75 96.502002) (end 153.75 96.29) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 97.565) (end 154.812998 97.565) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.812998 97.565) (end 153.75 96.502002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.225 95.815) (end 156.2 95.815) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 153.75 96.29) (end 154.225 95.815) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.849999 99.749999) (end 173 99.9) (width 0.5) (layer F.Cu) (net 33)) + (via (at 173 99.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 172.849999 98.837999) (end 172.849999 99.749999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 98.325) (end 173.362998 98.325) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.362998 98.325) (end 172.849999 98.837999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.025 99.9) (end 175.2 100.075) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173 99.9) (end 175.025 99.9) (width 0.5) (layer B.Cu) (net 33)) + (via (at 210.875 85.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 213.3 84.125) (end 211.912998 84.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.912998 84.125) (end 210.875 85.162998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 210.875 85.875) (end 206.225 85.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.3 85.875) (end 210.875 85.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 210.875 85.162998) (end 210.875 85.875) (width 0.5) (layer F.Cu) (net 33)) + (via (at 135.325 60.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 137.1 60.125) (end 135.325 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 130.414999 84.349999) (end 130 84.764998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 79.125) (end 133.075 82.187002) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 82.287002) (end 131.012003 84.349999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 131.012003 84.349999) (end 130.414999 84.349999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 130 84.764998) (end 130 93.607998) (width 0.5) (layer F.Cu) (net 33)) + (via (at 167.75 38.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.75 54.69) (end 167.75 56.677998) (width 0.5) (layer B.Cu) (net 33)) + (via (at 173.475 61.875) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 175.2 61.875) (end 173.475 61.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 167.325 78.115) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 175.2 79.225) (end 173.675 79.225) (width 0.5) (layer F.Cu) (net 33)) + (via (at 162.25 53.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 160.7 52.915) (end 161.375 52.915) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 161.375 52.915) (end 162.25 53.79) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 161.375 54.665) (end 160.7 54.665) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 162.25 53.79) (end 161.375 54.665) (width 0.5) (layer B.Cu) (net 33)) + (via (at 135.5 40.57501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 137.1 41.025) (end 136.65001 40.57501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 136.65001 40.57501) (end 135.5 40.57501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 104.5 79) (end 106.2 80.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 104.5 76.5) (end 104.5 79) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.400008 75.139774) (end 101.760234 76.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.760234 76.5) (end 104.5 76.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 106.6 81.1) (end 106.2 80.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 107.9 81.1) (end 106.6 81.1) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 167.325 78.115) (end 167.325 91.715) (width 0.5) (layer B.Cu) (net 33)) + (via (at 167.325 91.715) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.325 91.715) (end 166.42499 92.61501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 166.42499 97.42499) (end 171.33699 97.42499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 166.42499 92.61501) (end 166.42499 96.21499) (width 0.5) (layer F.Cu) (net 33)) + (via (at 166.42499 98.71499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 166.42499 96.21499) (end 166.42499 98.71499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 166.42499 98.71499) (end 166.42499 111.86501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 162.25 53.79) (end 167.75 53.79) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.75 38.44) (end 167.75 53.69) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.75 53.69) (end 167.75 54.69) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.3 64.925) (end 212.824996 64.925) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.2375 44.7375) (end 194.3 44.8) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.0125 44.7375) (end 194.2375 44.7375) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 44.8) (end 194.3 46.025) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.185 40.39) (end 156.2 40.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.15 101.825) (end 116.15 100.4) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 117.075 99.7) (end 116.85 99.7) (width 0.5) (layer F.Cu) (net 33)) + (via (at 116.85 99.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 118.1 100.725) (end 117.075 99.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 102.475) (end 116.8 102.475) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.8 102.475) (end 116.15 101.825) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.15 100.4) (end 116.85 99.7) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 104.875) (end 192.975 104.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 192.1 104) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 192.975 104.875) (end 192.1 104) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 103.125) (end 192.825 103.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.1 103.85) (end 192.1 104) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.825 103.125) (end 192.1 103.85) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 137.1 99.975) (end 135.774996 99.975) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135.317159 98.099999) (end 135 98.417158) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.774996 99.975) (end 135 99.200004) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135 98.507998) (end 135 99.200004) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135 98.417158) (end 135 99.200004) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 137.1 98.225) (end 136.974999 98.099999) (width 0.5) (layer F.Cu) (net 33)) + (via (at 135 99.200004) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 136.974999 98.099999) (end 135.317159 98.099999) (width 0.5) (layer F.Cu) (net 33)) + (via (at 134.375 79.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 137.1 79.125) (end 134.375 79.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 79.125) (end 134.375 79.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.375 80.325) (end 134.375 79.125) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 80.875) (end 134.925 80.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.925 80.875) (end 134.375 80.325) (width 0.5) (layer B.Cu) (net 33)) + (via (at 154.300002 77.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.325 78.115) (end 165 80.44) (width 0.5) (layer F.Cu) (net 33)) + (via (at 160.475 80.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 165 80.44) (end 160.475 80.44) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.300002 77.79) (end 154.300002 79.640002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.300002 79.640002) (end 155.3 80.64) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 160.42499 80.49001) (end 160.42499 80.44) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 155.3 80.64) (end 160.275 80.64) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 160.275 80.64) (end 160.42499 80.49001) (width 0.5) (layer B.Cu) (net 33)) + (via (at 173.1 81.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 172.475 80.625) (end 173.1 81.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.475 79.225) (end 172.475 80.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.675 79.225) (end 172.475 79.225) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 174.925 81.25) (end 175.2 80.975) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.1 81.25) (end 174.925 81.25) (width 0.5) (layer B.Cu) (net 33)) + (via (at 192.7 84.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 193.625 85.875) (end 192.706593 84.956593) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 85.875) (end 193.625 85.875) (width 0.5) (layer B.Cu) (net 33)) + (via (at 211.65 66.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 213.3 66.675) (end 212.225 66.675) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 212.225 66.675) (end 211.65 66.1) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 212.825 64.925) (end 213.3 64.925) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.65 66.1) (end 212.825 64.925) (width 0.5) (layer F.Cu) (net 33)) + (via (at 206.175 66.675) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.362996 42.775) (end 134.749998 42.162002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.749998 42.162002) (end 134.749998 41.325012) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 42.775) (end 135.362996 42.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.749998 41.325012) (end 135.5 40.57501) (width 0.5) (layer B.Cu) (net 33)) + (via (at 153.8 39.29) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 173.806234 42.08623) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 174.595004 42.875) (end 173.841595 42.121591) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 175.2 42.875) (end 174.595004 42.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.785002 42.064998) (end 173.806234 42.08623) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 83.475) (end 116.425 83.475) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 114.662001 81.712001) (end 116.35 83.4) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.425 83.475) (end 116.35 83.4) (width 0.5) (layer B.Cu) (net 33)) + (via (at 116.35 83.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 107.9 81.1) (end 108.512001 81.712001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 108.512001 81.712001) (end 114.662001 81.712001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 115.625011 82.675011) (end 116.35 83.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.625011 81.893733) (end 115.625011 82.675011) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 81.725) (end 117.980745 81.605745) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.980745 81.605745) (end 115.912999 81.605745) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.912999 81.605745) (end 115.625011 81.893733) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.999998 61.262002) (end 134.999998 60.450002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 134.999998 60.450002) (end 135.325 60.125) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135.612996 61.875) (end 134.999998 61.262002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 61.875) (end 135.612996 61.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173 61.4) (end 173.475 61.875) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173 60.5) (end 173 61.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 60.125) (end 173.375 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.375 60.125) (end 173 60.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 116.512998 64.475) (end 115.8 63.762002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 118.1 64.475) (end 116.512998 64.475) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 116.275 58.625) (end 118.3 58.625) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 115.8 59.1) (end 116.275 58.625) (width 0.5) (layer B.Cu) (net 33)) + (via (at 115.8 61.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 118.3 60.375) (end 116.925 60.375) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 116.925 60.375) (end 115.8 61.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.8 63.762002) (end 115.8 61.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 115.8 61.5) (end 115.8 59.1) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 117.025 62.725) (end 115.8 61.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.1 62.725) (end 117.025 62.725) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.8 61.5) (end 114.7 61.5) (width 0.5) (layer F.Cu) (net 33)) + (via (at 113 59.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 114.7 61.5) (end 113 59.8) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 113 59.8) (end 111.65 58.45) (width 0.5) (layer B.Cu) (net 33)) + (via (at 111.725 46.525) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 111.65 58.45) (end 111.65 46.6) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 110.25 48) (end 111.725 46.525) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 111.65 46.6) (end 111.725 46.525) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 111.725 46.525) (end 113.75 44.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.325 60.125) (end 134.617002 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.2 57.715) (end 154.625 57.715) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.099999 58.240001) (end 154.099999 60.539999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.625 57.715) (end 154.099999 58.240001) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.099999 60.539999) (end 155.1 61.54) (width 0.5) (layer F.Cu) (net 33)) + (via (at 161.65 60.89) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 155.1 61.54) (end 161 61.54) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 161 61.54) (end 161.65 60.89) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 163.637998 60.89) (end 167.75 56.777998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 161.65 60.89) (end 163.637998 60.89) (width 0.5) (layer B.Cu) (net 33)) + (via (at 154.099999 60.539999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 156.2 59.465) (end 155.174998 59.465) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 155.174998 59.465) (end 154.099999 60.539999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 165.825479 36.615479) (end 167.75 38.54) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.474521 36.615479) (end 165.825479 36.615479) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156 37.54) (end 156 37.09) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156 37.09) (end 156.474521 36.615479) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 195.175 62.25) (end 195.3 62.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 195.3 62.125) (end 194.475002 62.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.3 63.925) (end 194.3 64.925) (width 0.5) (layer F.Cu) (net 33)) + (via (at 193.3 63.925) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 197.92499 68.75) (end 198.87499 69.7) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 66.675) (end 194.3 68.75) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 68.75) (end 197.92499 68.75) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.65 66.1) (end 209.85 66.1) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 209.275 66.675) (end 206.175 66.675) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 209.85 66.1) (end 209.275 66.675) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 198.87499 69.7) (end 198.87499 69.7) (width 0.5) (layer B.Cu) (net 33) (tstamp 5F77CAAB)) + (via (at 198.87499 69.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 200.95 69.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 206.1 69.7) (end 206.175 69.625) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 67.175) (end 206.175 68.125) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 200.95 69.7) (end 206.1 69.7) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 68.125) (end 206.175 85.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 168.946 39.636) (end 168.946 39.65) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 135.225 60.125) (end 135.325 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.569998 63.4) (end 131.95 63.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 132.652 79.225) (end 129.45 76.023) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.849999 64.119999) (end 129.569998 63.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.849999 68.462001) (end 128.849999 64.119999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 133.075 79.225) (end 132.652 79.225) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.45 76.023) (end 129.45 69.062002) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 131.95 63.4) (end 135.225 60.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.45 69.062002) (end 128.849999 68.462001) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 187.25 119.445) (end 189.1 119.445) (width 0.25) (layer F.Cu) (net 33)) + (via (at 189.95 118.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 189.1 119.445) (end 189.895 118.65) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 189.895 118.65) (end 189.95 118.65) (width 0.25) (layer F.Cu) (net 33)) + (via (at 98.9664 127.6462) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (via (at 104.5036 128.3144) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 189.95 119.745) (end 189.95 118.65) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 188.5 121.195) (end 189.95 119.745) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 187.25 121.195) (end 188.5 121.195) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 175.2 119.175) (end 173.618 119.175) (width 0.25) (layer B.Cu) (net 33)) + (via (at 172.7818 117.399) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 173.618 119.175) (end 172.7818 118.3388) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 172.7818 118.3388) (end 172.7818 117.399) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 175.174 117.399) (end 175.2 117.425) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 172.7818 117.399) (end 175.174 117.399) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 172.7818 117.399) (end 167.8288 112.446) (width 0.25) (layer F.Cu) (net 33)) + (via (at 167.8034 111.8618) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.8288 112.446) (end 167.8288 111.8872) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 167.8288 111.8872) (end 167.8034 111.8618) (width 0.25) (layer F.Cu) (net 33)) + (via (at 166.42499 111.86501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 167.8034 111.8618) (end 166.4282 111.8618) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 166.4282 111.8618) (end 166.42499 111.86501) (width 0.25) (layer B.Cu) (net 33)) + (via (at 135.669468 118.748132) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.096599 118.175263) (end 135.669468 118.748132) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 135.096599 117.705799) (end 135.096599 118.175263) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 137.1 117.325) (end 135.477398 117.325) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 135.477398 117.325) (end 135.096599 117.705799) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 136.773132 118.748132) (end 137.1 119.075) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 135.669468 118.748132) (end 136.773132 118.748132) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 151.2836 116.2658) (end 151.2836 117.3876) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.6344 114.915) (end 151.2836 116.2658) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.7972 114.915) (end 152.6344 114.915) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 151.2836 119.1376) (end 153.7274 119.1376) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 154.4084 118.4566) (end 154.4084 117.8724) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 153.7274 119.1376) (end 154.4084 118.4566) (width 0.25) (layer B.Cu) (net 33)) + (via (at 153.2948 114.915) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 154.4084 117.8724) (end 153.2948 116.7588) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 153.2948 116.7588) (end 153.2948 114.915) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 156.2 114.915) (end 153.2948 114.915) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 153.2948 114.915) (end 152.7972 114.915) (width 0.5) (layer F.Cu) (net 33)) + (via (at 128.025 113.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 128 113.25) (end 128.025 113.25) (width 0.25) (layer F.Cu) (net 33)) + (via (at 130.1606 115.4178) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.096599 117.705799) (end 132.8086 115.4178) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 130.443442 115.4178) (end 130.1606 115.4178) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 130.1606 115.3856) (end 130.1606 115.4178) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 132.8086 115.4178) (end 130.443442 115.4178) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 128.025 113.25) (end 130.1606 115.3856) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 153.782 39.272) (end 153.8 39.29) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 153.782 38.75) (end 153.782 39.272) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 171.265 78.115) (end 167.325 78.115) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.475 79.325) (end 171.265 78.115) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.602158 40.375) (end 156.2 40.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.8 39.29) (end 153.8 39.572842) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.8 39.572842) (end 154.602158 40.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 44.45) (end 194.3 44.8) (width 0.5) (layer F.Cu) (net 33)) + (via (at 205.994 44.3738) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 206 44.3798) (end 205.994 44.3738) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 100.42262 68.79962) (end 100.42262 68.822612) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 100.42262 68.79962) (end 100.400388 68.79962) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.7 68.79962) (end 100.42262 68.79962) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128 113.25) (end 125.883 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 172.749999 98.837999) (end 172.849999 98.837999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 171.33699 97.42499) (end 172.749999 98.837999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.808 62.125) (end 192.532 61.849) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 195.3 62.125) (end 192.808 62.125) (width 0.5) (layer F.Cu) (net 33)) + (via (at 192.532 61.849) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 193.3 63.925) (end 192.4685 63.0935) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.4685 61.9125) (end 192.532 61.849) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.4685 63.0935) (end 192.4685 61.9125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 198.87499 69.7) (end 200.95 69.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206.132001 87.999999) (end 206.175 87.957) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 86.925) (end 206.175 87.957) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 87.45) (end 194.849999 87.999999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 85.875) (end 194.3 87.45) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 87.957) (end 206.175 93.832998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.849999 87.999999) (end 206.132001 87.999999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 171.425001 62.889999) (end 171.425001 61.562999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.25 78.04) (end 167.25 65.0965) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 168.8465 63.5) (end 170.815 63.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.325 78.115) (end 167.25 78.04) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.25 65.0965) (end 168.8465 63.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 170.815 63.5) (end 171.425001 62.889999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 171.425001 60.427001) (end 171.425001 61.562999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.7272 56.7438) (end 167.7418 56.7438) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.7418 56.7438) (end 171.425001 60.427001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 171.476 61.875) (end 171.45 61.849) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.475 61.875) (end 171.476 61.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 118.432842 98.4) (end 117.132842 99.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 122.1355 98.4) (end 118.432842 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.132842 99.7) (end 116.85 99.7) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 122.1355 98.4) (end 124.15 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128 101.9015) (end 128 113.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 124.15 98.4) (end 124.4985 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 124.4985 98.4) (end 128 101.9015) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 136.3326 120.904) (end 135.669468 120.240868) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 135.669468 120.240868) (end 135.669468 118.748132) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 150.241 120.904) (end 136.3326 120.904) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 151.2836 119.1376) (end 151.2836 119.8614) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 151.2836 119.8614) (end 150.241 120.904) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 154.83499 111.86501) (end 166.42499 111.86501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.7972 114.915) (end 152.7972 113.9028) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 152.7972 113.9028) (end 154.83499 111.86501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.8965 76.815) (end 154.300002 77.411498) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.300002 77.411498) (end 154.300002 77.79) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 156.2 76.815) (end 154.8965 76.815) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 192.7 84.6045) (end 192.7 84.95) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 84.125) (end 193.1795 84.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.1795 84.125) (end 192.7 84.6045) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 191.77 45.98) (end 193.0125 44.7375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.405 47.8155) (end 191.77 47.1805) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 191.77 47.1805) (end 191.77 45.98) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 47.775) (end 194.2595 47.8155) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.2595 47.8155) (end 192.405 47.8155) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.532 61.214) (end 192.532 61.849) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 195.3 60.375) (end 193.371 60.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 193.371 60.375) (end 192.532 61.214) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.0875 66.04) (end 192.0875 65.1375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.0875 65.1375) (end 193.3 63.925) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 194.3 66.675) (end 192.7225 66.675) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 192.7225 66.675) (end 192.0875 66.04) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 117.5485) (end 156.2 116.665) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 154.4084 118.4566) (end 155.2919 118.4566) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 155.2919 118.4566) (end 156.2 117.5485) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 101.030912 128.134039) (end 100.196873 127.3) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 99.3126 127.3) (end 98.9664 127.6462) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 100.196873 127.3) (end 99.3126 127.3) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 99.515367 129.009039) (end 98.6 128.093672) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 98.6 128.0126) (end 98.9664 127.6462) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 98.6 128.093672) (end 98.6 128.0126) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 101.545613 127.619338) (end 103.719338 127.619338) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 101.030912 128.134039) (end 101.545613 127.619338) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 104.4144 128.3144) (end 104.5036 128.3144) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 103.719338 127.619338) (end 104.4144 128.3144) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 104.5036 128.3144) (end 109.9856 128.3144) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.05 127.25) (end 111.05 125.005) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 109.9856 128.3144) (end 111.05 127.25) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.813828 122.863389) (end 113.631807 122.863389) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 111.422217 123.255) (end 111.813828 122.863389) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 111.05 123.255) (end 111.422217 123.255) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.523025 121.275487) (end 113.523025 120.676975) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.631807 122.863389) (end 113.631807 121.681468) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.631807 121.681468) (end 113.523025 121.275487) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 118.833 115.367) (end 119.667 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.523025 120.676975) (end 118.833 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 125.883 115.367) (end 119.667 115.367) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 113.633499 125.005) (end 114.08474 124.553759) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.05 125.005) (end 113.633499 125.005) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 111.05 125.005) (end 109.305 125.005) (width 0.25) (layer B.Cu) (net 33)) + (segment (start 109.305 125.005) (end 108.6 124.3) (width 0.25) (layer B.Cu) (net 33)) + (via (at 108.6 124.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 109.284728 123.255) (end 108.6 123.939728) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 108.6 123.939728) (end 108.6 124.3) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 111.05 123.255) (end 109.284728 123.255) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 130 93.607998) (end 131.607998 93.607998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135 97) (end 135 98.607998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 131.607998 93.607998) (end 135 97) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.617002 56.867002) (end 129.25 51.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.25 51.5) (end 129.25 49.837998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 127.5 41.5) (end 127.6 41.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.25 49.837998) (end 127.5 48.087998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.617002 60.225) (end 134.617002 56.867002) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 127.5 48.087998) (end 127.5 41.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206 47.5) (end 206 44.3798) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.820511 58.929489) (end 206 55.75) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206 55.75) (end 206 47.5) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 206.175 68.175) (end 202.820511 64.820511) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.820511 64.820511) (end 202.820511 58.929489) (width 0.5) (layer B.Cu) (net 33)) + (via (at 202.25 100.999998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 202.050001 101.199997) (end 202.25 100.999998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 103.125) (end 194.3 101.657524) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.757527 101.199997) (end 202.050001 101.199997) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.3 101.657524) (end 194.757527 101.199997) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 206.175 93.7006) (end 202.25 97.6256) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.25 97.6256) (end 202.25 100.999998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 124.507998 98.4) (end 124.15 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 130 93.607998) (end 129.3 93.607998) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.3 93.607998) (end 124.507998 98.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.749999 44.249999) (end 116 44.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 115.749999 43.137999) (end 115.749999 44.249999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 116.087999 42.799999) (end 115.749999 43.137999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.799999) (end 116.087999 42.799999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.799999) (end 118.1 43.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.87501 41.2) (end 135.5 40.57501) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.6 41.4) (end 134.67501 41.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.799999) (end 117.274999 42.725001) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.67501 41.4) (end 134.87501 41.2) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 117.274999 42.725001) (end 118.6 41.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 154.300002 78.544502) (end 154.300002 77.79) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 78.565) (end 154.3205 78.565) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.3205 78.565) (end 154.300002 78.544502) (width 0.5) (layer B.Cu) (net 33)) + (via (at 106.624999 82.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 106.624999 81.124999) (end 106.6 81.1) (width 0.25) (layer F.Cu) (net 33)) + (segment (start 106.624999 82.8) (end 106.624999 81.124999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 106.4 83.024999) (end 106.624999 82.8) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.4 87.350002) (end 106.4 83.024999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.575 87.375) (end 106.4 87.2) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.4 87.350002) (end 106.4 87.2) (width 0.25) (layer B.Cu) (net 33)) + (via (at 106.4 87.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 107.95 87.375) (end 106.575 87.375) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 106.4 85.925) (end 106.4 87.2) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 106.7 85.625) (end 106.4 85.925) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 107.95 85.625) (end 106.7 85.625) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 213.3 47.775) (end 212.939998 47.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.3 47.775) (end 213.025 47.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 213.4 46.025) (end 211.775 46.025) (width 0.5) (layer F.Cu) (net 33)) + (via (at 211.4 46.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 211.775 46.025) (end 211.4 46.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 213.4 47.775) (end 211.775 47.775) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.349999 47.349999) (end 211.349999 46.450001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.349999 46.450001) (end 211.4 46.4) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.775 47.775) (end 211.349999 47.349999) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 165.59998 99.54) (end 166.42499 98.71499) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.595 99.54) (end 165.59998 99.54) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 97.565) (end 156.2 99.145) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.2 99.145) (end 156.595 99.54) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 205.75 113.909) (end 205.75 105) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 189.95 118.65) (end 201.009 118.65) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 201.009 118.65) (end 205.75 113.909) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 202.25 101.45) (end 202.25 100.999998) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.625 104.875) (end 205.675 104.875) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 205.675 104.875) (end 202.25 101.45) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 211.6 103.5) (end 211.6 104.85) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 213.35 103.125) (end 211.975 103.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.6 104.85) (end 211.625 104.875) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.975 103.125) (end 211.6 103.5) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 98.3 84.453) (end 98.09999 84.65301) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.3 83.55) (end 98.3 84.453) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.09999 88.288481) (end 98.09999 84.65301) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.3 88.488491) (end 98.09999 88.288481) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.3 89.5) (end 98.3 88.488491) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 135.5 40.57501) (end 137.32501 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 137.32501 38.75) (end 139.588 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 139.334 38.75) (end 139.588 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 139.588 38.75) (end 156 38.75) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 174.767464 41.125) (end 175.2 41.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 173.806234 42.08623) (end 174.767464 41.125) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 187.739 39.464) (end 187.525 39.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 193.0125 44.7375) (end 187.739 39.464) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.707525 39.249999) (end 187.524999 39.249999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.319314 39.63821) (end 175.707525 39.249999) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 187.524999 39.249999) (end 187.739 39.464) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 167.75 38.44) (end 168.94821 39.63821) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 168.94821 39.63821) (end 175.319314 39.63821) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 39.757524) (end 175.319314 39.63821) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 41.125) (end 175.2 39.757524) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 209.7738 44.3738) (end 211.4 46) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 211.4 46) (end 211.4 46.4) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 205.994 44.3738) (end 209.7738 44.3738) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 194.62501 44.12499) (end 194.3 44.45) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 205.74519 44.12499) (end 194.62501 44.12499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 205.994 44.3738) (end 205.74519 44.12499) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 218.1 47.775) (end 218.475 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.325 46.25) (end 218.1 46.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.1 47.775) (end 218.125012 47.800012) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.1 47.775) (end 218.3916 47.775) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 218.1 46.025) (end 218.4148 46.025) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 92.18 46.26456) (end 93.478815 44.965745) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 92.18 46.31) (end 92.18 46.26456) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 91.67 45.8) (end 92.18 46.31) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 106.224255 44.965745) (end 107.42 43.77) (width 0.5) (layer F.Cu) (net 34) (status 20)) + (segment (start 106.876238 47.6) (end 108.7 47.6) (width 0.5) (layer F.Cu) (net 34) (status 20)) + (segment (start 105.676238 48.8) (end 106.876238 47.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 92.18 48.85) (end 92.23 48.8) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (via (at 96.7 67.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 96.7 68.79962) (end 96.7 67.8) (width 0.5) (layer B.Cu) (net 34) (status 10)) + (segment (start 97.474956 67.025044) (end 103.225042 67.025044) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.3 68.100002) (end 104.3 68.79962) (width 0.5) (layer F.Cu) (net 34) (status 20)) + (segment (start 96.7 67.8) (end 97.474956 67.025044) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.225042 67.025044) (end 104.3 68.100002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 96.9 51.552002) (end 96.9 48.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 96.7 67.8) (end 96.9 67.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 96.9 67.6) (end 96.9 51.552002) (width 0.5) (layer B.Cu) (net 34)) + (via (at 96.9 48.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 92.23 48.8) (end 96.9 48.8) (width 0.5) (layer F.Cu) (net 34) (status 10)) + (via (at 96.9 44.965745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 96.9 48.8) (end 96.9 44.965745) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 93.478815 44.965745) (end 96.9 44.965745) (width 0.5) (layer F.Cu) (net 34) (status 10)) + (segment (start 96.9 44.965745) (end 106.224255 44.965745) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.676238 48.8) (end 96.9 48.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.3 68.79962) (end 104.998242 68.79962) (width 0.5) (layer F.Cu) (net 34) (status 10)) + (segment (start 94.3 78.55) (end 94.3 83.55) (width 0.5) (layer B.Cu) (net 34) (status 20)) + (segment (start 90 74.25) (end 94.3 78.55) (width 0.5) (layer B.Cu) (net 34) (status 10)) + (segment (start 94.3 84.9) (end 94.3 89.5) (width 0.5) (layer B.Cu) (net 34) (status 20)) + (segment (start 94.3 83.55) (end 94.3 84.9) (width 0.5) (layer B.Cu) (net 34) (status 10)) + (segment (start 94.3 89.5) (end 93.538491 89.5) (width 0.5) (layer B.Cu) (net 34) (status 30)) + (segment (start 92.18 48.85) (end 92.18 46.31) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 108.718815 47.505745) (end 108.718815 50.045745) (width 0.5) (layer F.Cu) (net 34) (status 30)) + (segment (start 91.500001 103.500001) (end 92.5 104.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 91.049999 103.049999) (end 91.500001 103.500001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 94.3 98.053998) (end 93.176999 99.176999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 91.049999 101.303999) (end 91.049999 103.049999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 94.3 89.5) (end 94.3 98.053998) (width 0.5) (layer B.Cu) (net 34)) + (via (at 106.7 74.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 93.176999 99.176999) (end 91.049999 101.303999) (width 0.5) (layer B.Cu) (net 34) (tstamp 5D905040)) + (via (at 93.176999 99.176999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 107.6 76.3) (end 107.9 76) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.7 70.501378) (end 106.7 74.7) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.998242 68.79962) (end 106.7 70.501378) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 106.7 74.8) (end 107.9 76) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 106.7 74.7) (end 106.7 74.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.7 60.375) (end 122.625 60.375) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.7 62.125) (end 199.375 62.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 95.5 71.438176) (end 95.5 69.05311) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 95.5 69.05311) (end 95.6285 68.92461) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 94.738177 72.199999) (end 95.5 71.438176) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 90 74.25) (end 92.050001 72.199999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 92.050001 72.199999) (end 94.738177 72.199999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 96.57501 68.92461) (end 96.7 68.79962) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 95.6285 68.92461) (end 96.57501 68.92461) (width 0.5) (layer B.Cu) (net 34)) + (via (at 148.5 95.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 95.4) (end 149 95.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 142.125 40.8) (end 141.9 41.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.425 60.225) (end 148.5 60.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 160.000011 73.750011) (end 148.749989 73.750011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 79.65) (end 148.5 73.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.749989 73.650011) (end 148.5 73.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 73.9) (end 148.5 64.7) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 57.65) (end 148.5 53.9) (width 0.5) (layer B.Cu) (net 34)) + (via (at 124.5 44.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 144 40.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 144 40.8) (end 142.125 40.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 40.9) (end 144 40.9) (width 0.5) (layer B.Cu) (net 34)) + (via (at 153.625 52.915) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 156.3 54.665) (end 154.412998 54.665) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 156.3 52.915) (end 153.625 52.915) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 154.412998 54.665) (end 153.625 53.877002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 153.625 53.877002) (end 153.625 52.915) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 146 113.9) (end 147.15 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 59.949999) (end 186.025 60.125) (width 0.5) (layer B.Cu) (net 34)) + (via (at 182 79.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 200.75 85.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 199.225 85.75) (end 199.1 85.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 200.75 85.75) (end 199.225 85.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 186.924999 105.574999) (end 182.75 101.4) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.562001 98.249999) (end 180.075001 98.249999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180.075001 98.249999) (end 180 98.325) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.75 101.4) (end 182.75 99.437998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 113.574999) (end 186.924999 110.225001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 106.574999) (end 186.924999 105.574999) (width 0.5) (layer B.Cu) (net 34)) + (via (at 144.175 60.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 141.9 60.125) (end 144.175 60.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144.175 60.225) (end 148.425 60.225) (width 0.5) (layer B.Cu) (net 34)) + (via (at 181.975 60.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.025 60.125) (end 181.975 60.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.975 60.125) (end 180 60.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 62.725) (end 123.475 62.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 123.175 82) (end 122.9 81.725) (width 0.5) (layer B.Cu) (net 34)) + (via (at 111.75 88.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 111.75 88.5) (end 109.075 88.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 57.9) (end 148.5 57.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 60.15) (end 148.5 57.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 79.65) (end 148.5 91.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 67.499998) (end 186.5 72.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 59.949999) (end 186.5 60.249998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 60.249998) (end 186.5 67.499998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.2 59.949998) (end 186.200001 59.949999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 45.350001) (end 186.2 45.350002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.2 45.350002) (end 186.2 59.949998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144 41.95) (end 144 40.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 42.775) (end 143.175 42.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 143.175 42.775) (end 144 41.95) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 142.6 113.9) (end 146 113.9) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F76BAE9)) + (segment (start 186.5 72.15) (end 186.5 79.65) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F76BAED)) + (segment (start 124.675 100.725) (end 125.45 101.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 100.725) (end 124.675 100.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.149999 107.199999) (end 125.45 101.5) (width 0.5) (layer B.Cu) (net 34)) + (via (at 125.45 101.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 124.762001 102.550001) (end 125.45 101.862002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.45 101.862002) (end 125.45 101.5) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.9 102.475) (end 122.975001 102.550001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.975001 102.550001) (end 124.762001 102.550001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.175 104.875) (end 220.175021 104.874979) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.15 104.875) (end 220.175 104.875) (width 0.5) (layer F.Cu) (net 34)) + (via (at 220.175021 104.874979) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.924999 106.574999) (end 186.95 106.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 100.924999) (end 192.374999 100.924999) (width 0.5) (layer B.Cu) (net 34)) + (via (at 192.374999 100.924999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 192.374999 100.924999) (end 192.899998 100.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 192.899998 100.4) (end 200.1 100.4) (width 0.5) (layer F.Cu) (net 34)) + (via (at 200.1 100.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 200.1 102.125) (end 199.1 103.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 200.1 100.4) (end 200.1 102.125) (width 0.5) (layer B.Cu) (net 34)) + (via (at 201.5 104.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 201.062001 103.099999) (end 201.5 103.537998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.5 103.537998) (end 201.5 104.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.1 103.125) (end 199.125001 103.099999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.125001 103.099999) (end 201.062001 103.099999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 200.875 104.875) (end 199.1 104.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.5 104.25) (end 200.875 104.875) (width 0.5) (layer F.Cu) (net 34)) + (via (at 182.381001 99.068999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 181.375 100.075) (end 182.381001 99.068999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 100.075) (end 181.375 100.075) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.75 99.437998) (end 182.381001 99.068999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.381001 99.068999) (end 181.562001 98.249999) (width 0.5) (layer B.Cu) (net 34)) + (via (at 162.7 96.49) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 162.025 95.815) (end 162.7 96.49) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 95.815) (end 162.025 95.815) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161.625 97.565) (end 162.7 96.49) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 97.565) (end 161.625 97.565) (width 0.5) (layer F.Cu) (net 34)) + (via (at 144.9 98.900004) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 141.9 98.225) (end 144.224996 98.225) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 143.825004 99.975) (end 144.9 98.900004) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.9 98.9) (end 144.9 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144.224996 98.225) (end 144.9 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 99.975) (end 143.825004 99.975) (width 0.5) (layer F.Cu) (net 34)) + (via (at 144.95 79.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 144.925 79.125) (end 144.95 79.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 79.65) (end 148.1 79.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.1 79.25) (end 144.95 79.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 79.125) (end 144.925 79.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 80.875) (end 144.425 80.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.95 80.35) (end 144.95 79.15) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.425 80.875) (end 144.95 80.35) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.775 76.815) (end 163.2 77.24) (width 0.5) (layer B.Cu) (net 34)) + (via (at 163.2 77.24) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 161 76.815) (end 162.775 76.815) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.2 77.665) (end 163.2 77.24) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.3 78.565) (end 163.2 77.665) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 78.565) (end 162.3 78.565) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.300001 80.612001) (end 182.300001 79.950001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 181.575 79.225) (end 180 79.225) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.937002 80.975) (end 182.300001 80.612001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182 79.65) (end 181.575 79.225) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.300001 79.950001) (end 182 79.65) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 80.975) (end 181.937002 80.975) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 84.125) (end 199.225001 83.999999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.225001 83.999999) (end 201.162001 83.999999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.500001 84.337999) (end 201.500001 84.999999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.500001 84.999999) (end 200.75 85.75) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.162001 83.999999) (end 201.500001 84.337999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.1 82.05) (end 199.1 84.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 198.3 81.25) (end 199.1 82.05) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 79.75) (end 188 81.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 188 81.25) (end 198.3 81.25) (width 0.5) (layer B.Cu) (net 34)) + (via (at 212.5 81) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 216.85 81) (end 212.5 81) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.587002 85.875) (end 220.562002 84.9) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.1 85.875) (end 219.587002 85.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.562002 84.9) (end 220.562002 83.212002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.1 84.125) (end 219.025 83.2) (width 0.5) (layer B.Cu) (net 34)) + (via (at 220.562002 83.212002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 219.025 83.2) (end 220.55 83.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.55 83.2) (end 220.562002 83.212002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.562002 83.212002) (end 220.562002 82.662002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.9 81) (end 217 81) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.562002 82.662002) (end 218.9 81) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.175 66.675) (end 220.2 66.65) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.223789 64.801211) (end 219.584053 64.801211) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.2 65.417158) (end 220.2 66.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.584053 64.801211) (end 220.2 65.417158) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.1 64.925) (end 218.223789 64.801211) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.1 66.675) (end 220.175 66.675) (width 0.5) (layer F.Cu) (net 34)) + (via (at 220.2 66.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 124.2 43.625) (end 124.5 43.925) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 43.625) (end 124.2 43.625) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.5 43.925) (end 124.5 44.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.5 44.25) (end 124.5 44.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 123.925 45.375) (end 122.9 45.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.5 44.8) (end 123.925 45.375) (width 0.5) (layer F.Cu) (net 34)) + (via (at 117.15 47.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 123 46.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 123 45.475) (end 122.9 45.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 123 46.95) (end 123 45.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.65 47.3) (end 123 46.95) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 117.15 47.1) (end 117.35 47.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 117.35 47.3) (end 122.65 47.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 38.625) (end 162.685 38.625) (width 0.5) (layer B.Cu) (net 34)) + (via (at 163.85 39.89) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 162.685 38.625) (end 163.85 39.79) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.85 39.79) (end 163.85 39.89) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.365 40.375) (end 161 40.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 163.85 39.89) (end 163.365 40.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 40.375) (end 161 41.375) (width 0.5) (layer F.Cu) (net 34)) + (via (at 181.7 43.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.200001 45.350001) (end 184.05 43.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 41.125) (end 181.3 41.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.3 41.125) (end 181.7 41.525) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.7 41.525) (end 181.7 43.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 181.375 42.875) (end 181.7 43.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 42.875) (end 181.375 42.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 184.05 43.2) (end 181.7 43.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.1 46.025) (end 201.525 46.025) (width 0.5) (layer B.Cu) (net 34)) + (via (at 201.75 47.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 201.525 46.025) (end 201.75 46.25) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.75 46.25) (end 201.75 47.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.125 47.8) (end 199.1 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.75 47.8) (end 199.125 47.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 47.775) (end 199.1 48.825) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 111.75 88.5) (end 114.7 85.55) (width 0.5) (layer F.Cu) (net 34)) + (via (at 123.95 85.55) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 114.7 85.55) (end 117.3198 85.55) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.637002 81.725) (end 126.25 83.337998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 81.725) (end 124.637002 81.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.362002 85.55) (end 123.95 85.55) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.25 83.662002) (end 124.362002 85.55) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.25 83.337998) (end 126.25 83.662002) (width 0.5) (layer B.Cu) (net 34)) + (via (at 215.8 101.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 144.374999 61.337005) (end 144.374999 60.324999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 143.837004 61.875) (end 144.374999 61.337005) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 61.875) (end 143.837004 61.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 144.374999 60.324999) (end 144.175 60.125) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180 61.875) (end 181.787004 61.875) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.300001 61.362003) (end 182.300001 60.450001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.300001 60.450001) (end 181.975 60.125) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 181.787004 61.875) (end 182.300001 61.362003) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.537002 64.475) (end 122.9 64.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 63.762001) (end 124.537002 64.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.687002 58.625) (end 125.250001 59.187999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.7 58.625) (end 124.687002 58.625) (width 0.5) (layer F.Cu) (net 34)) + (via (at 125.250001 60.399999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 125.225002 60.375) (end 125.250001 60.399999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 125.250001 59.187999) (end 125.250001 60.399999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 122.7 60.375) (end 125.225002 60.375) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 117.14965 47.09965) (end 117.15 47.1) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 114.34965 47.09965) (end 117.14965 47.09965) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 108.718815 50.045745) (end 111.403555 50.045745) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 111.403555 50.045745) (end 114.34965 47.09965) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 63.300001) (end 125.250001 63.762001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 60.399999) (end 125.250001 63.300001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.95 58.365) (end 162.95 59.590002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 57.715) (end 162.3 57.715) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 162.3 57.715) (end 162.95 58.365) (width 0.5) (layer B.Cu) (net 34)) + (via (at 162.95 59.590002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 161 59.465) (end 162.824998 59.465) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.824998 59.465) (end 162.95 59.590002) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 66.675) (end 200.287002 66.675) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.1 64.925) (end 200.825 64.925) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.300005 65.400005) (end 201.300005 67.199995) (width 0.5) (layer B.Cu) (net 34)) + (via (at 201.056001 67.443999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 200.287002 66.675) (end 201.056001 67.443999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 200.825 64.925) (end 201.300005 65.400005) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.300005 67.199995) (end 201.056001 67.443999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.9 63.85) (end 200.825 64.925) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.7 62.125) (end 201.9 62.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.9 62.125) (end 201.9 63.85) (width 0.5) (layer B.Cu) (net 34)) + (via (at 204.5 52.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 209.45 64.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 209.45 67.5) (end 209.35 67.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 209.45 64.25) (end 209.45 67.5) (width 0.5) (layer B.Cu) (net 34)) + (via (at 209.35 67.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 213.264998 68.75) (end 218.1 68.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.35 67.6) (end 212.114998 67.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 212.114998 67.6) (end 213.264998 68.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 186.924999 110.225001) (end 186.924999 106.574999) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F77CAB5)) + (via (at 186.924999 110.225001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 52.3) (end 148.5 46.1) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F77CAB9)) + (via (at 124.598 80.950008) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 124.637002 80.98901) (end 124.598 80.950008) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.935003 63.300001) (end 127.800001 64.164999) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 124.637002 81.725) (end 124.637002 80.98901) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 127.800001 77.748007) (end 124.598 80.950008) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 125.250001 63.300001) (end 126.935003 63.300001) (width 0.5) (layer F.Cu) (net 34)) + (via (at 104.6 125.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 185.828198 117.3736) (end 186.924999 116.276799) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 113.674999) (end 186.924999 116.276799) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.992 117.425) (end 183.0434 117.3736) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 117.425) (end 182.992 117.425) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 120.3754) (end 180 119.175) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 180.8196 121.195) (end 180 120.3754) (width 0.5) (layer F.Cu) (net 34)) + (via (at 181.200002 117.425) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 181.3022 121.195) (end 180.8196 121.195) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 182.85 121.195) (end 181.3022 121.195) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 184.4912 119.0538) (end 184.1 119.445) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.4912 117.3736) (end 184.4912 119.0538) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.4912 117.3736) (end 185.828198 117.3736) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.1 119.445) (end 182.85 119.445) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 183.0434 117.3736) (end 184.4912 117.3736) (width 0.5) (layer B.Cu) (net 34)) + (via (at 146.8836 115.7832) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 146.8836 115.7832) (end 146.8836 114.1664) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 146.8836 117.3876) (end 146.8836 115.7832) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 53.2138) (end 148.5 52.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 153.3262 53.2138) (end 153.625 52.915) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 53.9) (end 148.5 53.2138) (width 0.5) (layer B.Cu) (net 34)) + (via (at 163.5108 112.5814) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 163.481389 112.551989) (end 163.5108 112.5814) (width 0.5) (layer B.Cu) (net 34)) + (via (at 120.909801 123.820001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 105.418 130.194) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 154.7368 93.46499) (end 161.32499 93.46499) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.7 94.84) (end 162.7 96.49) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161.32499 93.46499) (end 162.7 94.84) (width 0.5) (layer F.Cu) (net 34)) + (via (at 148.1328 91.9988) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 149.0472 95.3528) (end 149 95.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 149.07961 93.46499) (end 149.0472 93.4974) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 154.7368 93.46499) (end 149.07961 93.46499) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 149.0472 92.1258) (end 149.0472 93.4974) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 149.0472 93.4974) (end 149.0472 95.3528) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 161 74.7924) (end 159.9438 73.7362) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 76.815) (end 161 74.7924) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.162004 85.75) (end 200.75 85.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 204.412004 82.5) (end 201.162004 85.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 212.5 81) (end 211 82.5) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 211 82.5) (end 204.8375 82.5) (width 0.5) (layer F.Cu) (net 34)) + (via (at 172.7708 38.9382) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 172.7708 38.9382) (end 169.8244 38.9382) (width 0.5) (layer F.Cu) (net 34)) + (via (at 167.894 37.4396) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 169.8244 38.9382) (end 169.2431 38.3569) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 168.3258 37.4396) (end 167.894 37.4396) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 166.3004 37.4396) (end 165.37 38.37) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 167.894 37.4396) (end 166.3004 37.4396) (width 0.5) (layer B.Cu) (net 34)) + (via (at 211.378787 48.652217) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 218.1 68.75) (end 219.3368 68.75) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.2 67.8868) (end 220.2 66.65) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 219.3368 68.75) (end 220.2 67.8868) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.684002 68.072) (end 203.454 68.072) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.056001 67.443999) (end 201.684002 68.072) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 203.926 67.6) (end 209.35 67.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 203.454 68.072) (end 203.926 67.6) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 131.149999 113.052403) (end 131.149999 107.099999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.997596 113.9) (end 131.149999 113.052403) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.7805 118.4907) (end 148.7805 116.974498) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 146.8836 119.1376) (end 148.1336 119.1376) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 148.1336 119.1376) (end 148.7805 118.4907) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 142.1535 117.325) (end 143.383 118.5545) (width 0.5) (layer B.Cu) (net 34)) + (via (at 143.383 118.5545) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 142.4205 118.5545) (end 143.383 118.5545) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 119.075) (end 142.4205 118.5545) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 141.9 117.325) (end 142.1535 117.325) (width 0.5) (layer B.Cu) (net 34)) + (via (at 199.099994 48.824994) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 201.75 47.8) (end 201.75 49.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 203.95 51.5) (end 204.5 52.05) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.75 49.3) (end 203.95 51.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 202.025 62.125) (end 202.1205 62.0295) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 202.1205 62.0295) (end 202.1205 60.959998) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 201.535502 60.375) (end 202.1205 60.959998) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 199.7 62.125) (end 202.025 62.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.7 60.375) (end 201.535502 60.375) (width 0.5) (layer F.Cu) (net 34)) + (via (at 202.1205 60.959998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 161.000002 41.375002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 122.9 62.725) (end 124.4095 62.725) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 125.250001 61.884499) (end 125.250001 60.399999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 124.4095 62.725) (end 125.250001 61.884499) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 144.999996 98.900004) (end 144.9 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 95.4) (end 144.999996 98.900004) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 142.6 113.9) (end 141.967 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.967 113.9) (end 131.997596 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.182399 112.252999) (end 163.310801 112.381401) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 163.310801 112.381401) (end 163.5108 112.5814) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 149.8902 113.9) (end 151.537201 112.252999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 147.15 113.9) (end 149.8902 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 151.537201 112.252999) (end 163.182399 112.252999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 113.9) (end 148.5 112.3) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 146.8836 113.9744) (end 146.958 113.9) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 146.8836 114.1664) (end 146.8836 113.9744) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 146 113.9) (end 146.958 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 146.958 113.9) (end 148.5 113.9) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.9 83.475) (end 123.1625 83.475) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 198.6915 49.7205) (end 199.099994 49.312006) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 199.099994 49.312006) (end 199.099994 48.824994) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.200001 45.450001) (end 187.948034 45.450001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 192.218533 49.7205) (end 198.6915 49.7205) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 187.948034 45.450001) (end 191.549016 49.050984) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 101.946161 133.165961) (end 102.878 134.0978) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 101.915367 133.165961) (end 101.946161 133.165961) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 106.65 125.005) (end 104.681 125.005) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 120 120.2) (end 120 121.1) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 119.478943 121.621057) (end 118.268251 121.621057) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 120 121.1) (end 119.478943 121.621057) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 120.401227 123.311427) (end 120.909801 123.820001) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 118.721184 123.311427) (end 120.401227 123.311427) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 120.909801 123.820001) (end 120.909801 121.109801) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 120.909801 121.109801) (end 119.9 120.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 119.9 120.1) (end 120 120.2) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 161 116.665) (end 161.635 116.665) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 163.5108 112.5814) (end 163.5108 114.7892) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 163.5108 114.7892) (end 162.6 115.7) (width 0.5) (layer F.Cu) (net 34)) + (via (at 162.6 115.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 161.635 116.665) (end 162.6 115.7) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 162.115 114.915) (end 162.6 115.4) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161 114.915) (end 162.115 114.915) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 162.6 115.4) (end 162.6 115.7) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 79.225) (end 141.9 77.5) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.82499 77.42499) (end 141.82499 77.12499) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 77.5) (end 141.82499 77.42499) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.82499 77.12499) (end 140.8 76.1) (width 0.5) (layer B.Cu) (net 34)) + (via (at 127.800001 76.100001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 127.800002 76.1) (end 127.800001 76.100001) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 140.8 76.1) (end 139.4 76.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 127.800001 64.164999) (end 127.800001 76.100001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 127.800001 76.100001) (end 127.800001 77.748007) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 181.200002 118.299998) (end 181.200002 117.425) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 180 119.175) (end 180.325 119.175) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 180.325 119.175) (end 181.200002 118.299998) (width 0.25) (layer F.Cu) (net 34)) + (segment (start 141.9 116.2) (end 142.5 115.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 141.9 117.325) (end 141.9 116.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 142.5 114) (end 142.6 113.9) (width 0.25) (layer B.Cu) (net 34)) + (segment (start 142.5 115.6) (end 142.5 114) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 208.6 50) (end 209.947783 48.652217) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.947783 48.652217) (end 211.378787 48.652217) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 207.2 50) (end 208.6 50) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 204.5 52.05) (end 205.15 52.05) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 205.15 52.05) (end 207.2 50) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 169.2431 38.3569) (end 168.3258 37.4396) (width 0.5) (layer F.Cu) (net 34) (tstamp 5F808024)) + (segment (start 139.4 76.1) (end 127.800002 76.1) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F808028)) + (via (at 139.4 76.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 101.7) (end 148.5 95.4) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F80802A)) + (via (at 148.5 101.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 112.3) (end 148.5 101.7) (width 0.5) (layer B.Cu) (net 34) (tstamp 5F80802C)) + (via (at 148.5 112.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 151.899698 40.525011) (end 153.814687 42.44) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 160.401831 42.44) (end 161.000002 41.841829) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 151.749698 40.525011) (end 151.899698 40.525011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 149.362989 40.137011) (end 151.361698 40.137011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 151.361698 40.137011) (end 151.749698 40.525011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 161.000002 41.841829) (end 161.000002 41.375002) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 153.814687 42.44) (end 160.401831 42.44) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 148.5 41) (end 149.362989 40.137011) (width 0.5) (layer B.Cu) (net 34)) + (via (at 156.8069 132.2705) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 206.629 96.1009) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 99.9998 104.4956) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 204.8375 82.5) (end 204.412004 82.5) (width 0.5) (layer F.Cu) (net 34) (tstamp 5F885627)) + (via (at 204.8375 82.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 102 87.325) (end 102 86) (width 0.5) (layer F.Cu) (net 34)) + (via (at 102 86) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 103.55 87.375) (end 102.05 87.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 102.05 87.375) (end 102 87.325) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.175 86) (end 103.55 85.625) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 102 86) (end 103.175 86) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.638 76) (end 105.4 77.238) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.4 87.025) (end 105.4 84) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.4 77.238) (end 105.4 84) (width 0.5) (layer B.Cu) (net 34)) + (via (at 105.4 84) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 103.55 87.375) (end 105.05 87.375) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.05 87.375) (end 105.4 87.025) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 107.9 76) (end 106.638 76) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 211.378787 48.652217) (end 211.378787 49.178787) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 211.378787 49.178787) (end 212 49.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 218.2 49.143876) (end 218.2 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 217.543876 49.8) (end 218.2 49.143876) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 212 49.8) (end 217.543876 49.8) (width 0.5) (layer F.Cu) (net 34)) + (via (at 220.4 47.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 218.2 47.775) (end 220.375 47.775) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.375 47.775) (end 220.4 47.8) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 220.4 47.8) (end 220.4 46.4) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.4 46.4) (end 220 46) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.975 46.025) (end 218.2 46.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220 46) (end 219.975 46.025) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218.15 101.35) (end 218.15 103.125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 218 101.2) (end 218.15 101.35) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 217.8 101.2) (end 217.7 101.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 219.262002 101.2) (end 217.8 101.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.175021 104.874979) (end 220.175021 102.113019) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 217.7 101.1) (end 215.8 101.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 220.175021 102.113019) (end 219.262002 101.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 172.909 38.8) (end 172.7708 38.9382) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 182.945 38.8) (end 172.909 38.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.05 43.2) (end 184.05 39.905) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 184.05 39.905) (end 182.945 38.8) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 212.906 101.1) (end 215.8 101.1) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 202.55 103.2) (end 206.064998 103.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 201.5 104.25) (end 202.55 103.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 206.064998 103.2) (end 207.364999 104.500001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 207.364999 104.500001) (end 209.505999 104.500001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.505999 104.500001) (end 212.906 101.1) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 105.418 132.182) (end 105.418 130.194) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.418 132.182) (end 105.418 132.768814) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.418 132.768814) (end 104.236815 133.949999) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 104.236815 133.949999) (end 104.236815 133.963185) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 104.236815 133.963185) (end 103.8 134.4) (width 0.5) (layer B.Cu) (net 34)) + (via (at 103.8 134.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 103.149406 134.4) (end 101.915367 133.165961) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.8 134.4) (end 103.149406 134.4) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 103.8 132.660049) (end 103.430912 132.290961) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 103.8 134.4) (end 103.8 132.660049) (width 0.5) (layer B.Cu) (net 34)) + (via (at 140.8 132.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 170.4 132.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 217 81) (end 216.85 81) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0731)) + (via (at 217 81) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 191.549016 49.050984) (end 192.218533 49.7205) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0733)) + (via (at 191.549016 49.050984) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 64.7) (end 148.5 61.5) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0735)) + (segment (start 148.5 61.5) (end 148.5 60.15) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0737)) + (via (at 133 78) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.5 46.1) (end 148.5 40.9) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC0739)) + (segment (start 165.37 38.37) (end 163.85 39.89) (width 0.5) (layer B.Cu) (net 34) (tstamp 5FDC073B)) + (via (at 165.37 38.37) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 125.67499 125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 125.67499 118.990008) (end 125.67499 125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 126.935798 117.7292) (end 125.67499 118.990008) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 125.07499 125.6) (end 125.67499 125) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 130.3638 117.7292) (end 126.935798 117.7292) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.75 116.343) (end 130.3638 117.7292) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 131.75 114) (end 131.75 116.343) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 122.6898 125.6) (end 125.07499 125.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 120.909801 123.820001) (end 122.6898 125.6) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.65 123.255) (end 108.15 123.255) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 109.884988 120.401826) (end 111.411803 118.875011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 111.411803 118.875011) (end 118.675011 118.875011) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 109.884988 121.520012) (end 109.884988 120.401826) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 108.15 123.255) (end 109.884988 121.520012) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 118.675011 118.875011) (end 119.9 120.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 104.6 124.055) (end 104.6 125.086) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.4 123.255) (end 104.6 124.055) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 106.65 123.255) (end 105.4 123.255) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 105.418 127.018) (end 105.418 130.194) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.6 125.2) (end 104.6 126.2) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.6 126.2) (end 105.418 127.018) (width 0.5) (layer F.Cu) (net 34)) + (via (at 169.7228 56.1848) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 167.0304 56.1848) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 169.7228 56.1848) (end 167.0304 56.1848) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 165.137002 58.365) (end 162.95 58.365) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 167.0304 56.471602) (end 165.137002 58.365) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 167.0304 56.1848) (end 167.0304 56.471602) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 169.7076 56.2) (end 169.7228 56.1848) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 177.544076 56.2) (end 169.7076 56.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 58.655924) (end 177.544076 56.2) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 180 60.125) (end 180 58.655924) (width 0.5) (layer B.Cu) (net 34)) + (via (at 209.45 64.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 209.45 64.25) (end 209.45 59.7) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 206.6756 53.5756) (end 205.15 52.05) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 206.6756 56.9256) (end 206.6756 53.5756) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 209.45 59.7) (end 206.6756 56.9256) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 186.5 85.662) (end 185.187 84.349) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 91.574999) (end 186.5 91.15) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.924999 105.574999) (end 186.924999 102.152401) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 91.15) (end 186.5 85.662) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 185.187 79.65) (end 182 79.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 185.187 84.349) (end 185.187 79.65) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 186.5 79.65) (end 185.187 79.65) (width 0.5) (layer B.Cu) (net 34)) + (via (at 189.992 80.4418) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 172.7708 76.3778) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 186.924999 102.152401) (end 186.924999 91.574999) (width 0.5) (layer B.Cu) (net 34) (tstamp 61CC37ED)) + (via (at 186.924999 102.152401) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 168.021 95.7834) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 171.4246 100.3046) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 173.8376 102.4636) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 173.6344 115.7224) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 168.4274 110.0836) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 185.5978 85.5472) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 185.0644 77.4446) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 167.8686 121.158) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 131.9784 118.3894) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 111.4806 114.6556) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 128.6764 92.6592) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 114.0714 102.3874) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 113.792 63.1444) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 113.1062 69.0118) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 117.3198 85.55) (end 123.95 85.55) (width 0.5) (layer F.Cu) (net 34) (tstamp 61CC3F51)) + (via (at 117.3198 85.55) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 136.3218 96.0628) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.3446 63.246) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.37 60.1472) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.7256 50.165) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 166.243 45.339) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 185.5978 123.6472) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 149.0218 127.2032) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 96.7232 125.5522) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 150.0632 36.8808) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 174.371 36.8808) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 133.8072 101.8794) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 130.3782 110.1344) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 131.8768 122.7074) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 152.6032 98.8822) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 117.729 104.5718) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 122.5804 97.282) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (via (at 135.1026 115.9256) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 148.7805 116.974498) (end 147.589202 115.7832) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 147.589202 115.7832) (end 146.8836 115.7832) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 152.196 53.2138) (end 148.5 53.2138) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 153.3262 53.2138) (end 152.196 53.2138) (width 0.5) (layer B.Cu) (net 34)) + (via (at 146.939 46.2788) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 220.5 59.75) (end 220.5 58.42) (width 0.25) (layer F.Cu) (net 35) (tstamp 5F754BC2)) + (segment (start 220.5 58.42) (end 221.4 57.52) (width 0.25) (layer F.Cu) (net 35) (tstamp 5F754BC3)) + (via (at 220.5 59.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35) (tstamp 5F754BC8)) + (segment (start 106.17 57.67) (end 107.47 56.37) (width 0.25) (layer F.Cu) (net 35) (tstamp 5AB4FE5D) (status 20)) + (segment (start 106.165745 57.665745) (end 106.17 57.67) (width 0.25) (layer F.Cu) (net 35)) + (via (at 102.675 57.665745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 102.675 57.665745) (end 93.478815 57.665745) (width 0.25) (layer F.Cu) (net 35) (status 20)) + (segment (start 106.165745 57.665745) (end 102.675 57.665745) (width 0.25) (layer F.Cu) (net 35)) + (via (at 220.75 97.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 210 95.62) (end 212.13 97.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 212.13 97.75) (end 220.75 97.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 220.75 97.75) (end 220.75 96.27) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 61.305001) (end 220.5 59.75) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.4 72.567002) (end 222.055001 71.912001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 71.912001) (end 222.055001 61.305001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.4 76.42) (end 221.4 72.567002) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 81.305001) (end 222.055001 81.055001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 210.05 76.62) (end 211.979989 78.549989) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 222.055001 79.979991) (end 220.55 78.47499) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.55 77.52) (end 220.55 78.47499) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.475001 78.549989) (end 220.55 78.47499) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 221.45 76.62) (end 220.55 77.52) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 211.979989 78.549989) (end 220.475001 78.549989) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 222.055001 81.055001) (end 222.055001 79.979991) (width 0.25) (layer F.Cu) (net 35)) + (via (at 220.55 78.47499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 222.055001 87.805001) (end 222.055001 81.055001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.4 95.62) (end 222.055001 94.964999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.055001 94.964999) (end 222.055001 87.805001) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.75 96.27) (end 221.4 95.62) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 114.62) (end 220.75 113.92) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 210.05 114.62) (end 210.05 116.47499) (width 0.25) (layer B.Cu) (net 35)) + (via (at 210 116.49999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 210.05 114.62) (end 210.05 116.44999) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 210.05 116.44999) (end 210 116.49999) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 210.025 116.47499) (end 210 116.49999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 114.62) (end 221.45 116.132842) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.107852 116.47499) (end 210.025 116.47499) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 116.132842) (end 221.107852 116.47499) (width 0.25) (layer F.Cu) (net 35)) + (via (at 177.303 130.988) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35)) + (segment (start 171.9 128.92) (end 173.968 130.988) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 173.968 130.988) (end 177.303 130.988) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 181.232 130.988) (end 183.3 128.92) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 177.303 130.988) (end 181.232 130.988) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 220.75 100.71359) (end 220.75 96.27) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.275009 101.238599) (end 220.75 100.71359) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.85 113.37) (end 222.85 107.35) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.6 114.62) (end 222.85 113.37) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.45 114.62) (end 221.6 114.62) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 222.85 107.35) (end 221.275009 105.775009) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 221.275009 105.775009) (end 221.275009 101.238599) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 202.929 118) (end 204.42901 116.49999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 204.42901 116.49999) (end 210 116.49999) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 194.3565 118) (end 202.929 118) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 183.3 128.92) (end 183.4365 128.92) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 183.4365 128.92) (end 194.3565 118) (width 0.25) (layer F.Cu) (net 35)) + (segment (start 188.825423 38.2) (end 188.854605 38.204605) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 169.90858 36.38078) (end 171.7278 38.2) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 153 37.75) (end 154.36922 36.38078) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 171.7278 38.2) (end 188.825423 38.2) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 102.675 41.054355) (end 105.964678 37.764678) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 188.854605 38.204605) (end 189.05 38.4) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 154.36922 36.38078) (end 169.90858 36.38078) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 152.214678 37.764678) (end 152.229356 37.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 102.675 57.665745) (end 102.675 41.054355) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 105.964678 37.764678) (end 152.214678 37.764678) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 152.229356 37.75) (end 153 37.75) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 194.2364 43.5864) (end 189.054628 38.404628) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 208.0006 43.5864) (end 194.2364 43.5864) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 212.2462 59.7662) (end 209.25 56.77) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 209.25 44.8358) (end 208.0006 43.5864) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 209.25 56.77) (end 209.25 44.8358) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 220.5162 59.7662) (end 212.2462 59.7662) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 220.5 59.75) (end 220.5162 59.7662) (width 0.25) (layer B.Cu) (net 35)) + (segment (start 201.3 58.52) (end 202.2 57.62) (width 0.25) (layer F.Cu) (net 36) (tstamp 5F754BC3)) + (segment (start 190.8 57.62) (end 190.82 57.62) (width 0.25) (layer B.Cu) (net 36) (tstamp 5F754BC4)) + (segment (start 201.5 78.65) (end 201.5 77.32) (width 0.25) (layer F.Cu) (net 36) (tstamp 5F754BC2)) + (segment (start 201.5 77.32) (end 202.4 76.42) (width 0.25) (layer F.Cu) (net 36) (tstamp 5F754BC3)) + (segment (start 191 76.42) (end 191.02 76.42) (width 0.25) (layer B.Cu) (net 36) (tstamp 5F754BC4)) + (via (at 201.5 78.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36) (tstamp 5F754BC8)) + (segment (start 106.224255 60.205745) (end 107.42 59.01) (width 0.25) (layer F.Cu) (net 36) (status 20)) + (via (at 103.175 60.205745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 103.175 60.205745) (end 106.224255 60.205745) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 93.478815 60.205745) (end 103.175 60.205745) (width 0.25) (layer F.Cu) (net 36) (status 10)) + (via (at 189.275 57.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 190.73 57.25) (end 191 57.52) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.275 57.25) (end 190.73 57.25) (width 0.25) (layer B.Cu) (net 36)) + (via (at 188 46.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 189.275 57.25) (end 189.275 47.775) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.275 47.775) (end 188 46.5) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 188 46.5) (end 181.5 40) (width 0.25) (layer F.Cu) (net 36)) + (via (at 181.5 39.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (via (at 190.85 77.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 201.5 78.65) (end 191.6 78.65) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 191.6 78.65) (end 190.85 77.9) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 190.85 76.57) (end 191 76.42) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.85 77.9) (end 190.85 76.57) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.275 58.312502) (end 189.275 57.25) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 190.199998 59.2375) (end 189.275 58.312502) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 190.05 64.4) (end 190.15 64.3) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.199998 64.250002) (end 190.15 64.3) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 191 76.42) (end 191 75.17) (width 0.25) (layer B.Cu) (net 36)) + (via (at 190.15 64.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 191 75.17) (end 190.05 74.22) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.05 74.22) (end 190.05 64.4) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.199998 59.2375) (end 190.199998 64.250002) (width 0.25) (layer F.Cu) (net 36)) + (via (at 191.2984 119.9136) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 172.67459 120.93521) (end 179.514489 120.93521) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 189.191999 122.020001) (end 191.2984 119.9136) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 179.514489 120.93521) (end 180.59928 122.020001) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 180.59928 122.020001) (end 189.191999 122.020001) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 191 114.62) (end 193.276189 116.896189) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 193.276189 116.896189) (end 201.008609 116.896189) (width 0.25) (layer B.Cu) (net 36)) + (via (at 193.276189 116.9842) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 191.2984 119.9136) (end 191.2984 118.961989) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 191.2984 118.961989) (end 193.276189 116.9842) (width 0.25) (layer F.Cu) (net 36)) + (via (at 202.005399 115.899399) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 201.008609 116.896189) (end 202.005399 115.899399) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 190.267499 59.305001) (end 190.199998 59.2375) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 202.4 57.52) (end 200.614999 59.305001) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 200.614999 59.305001) (end 190.267499 59.305001) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 203.2 93.57) (end 203.2 87.1855) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 202.4 94.37) (end 203.2 93.57) (width 0.25) (layer F.Cu) (net 36)) + (via (at 203.2 87.1855) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 201.5 78.65) (end 203.2 80.35) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 203.2 80.35) (end 203.2 87.1855) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.4 95.62) (end 202.4 94.37) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 167.177 126.41) (end 167.1884 126.4214) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 164.3 126.41) (end 167.177 126.41) (width 0.25) (layer F.Cu) (net 36)) + (via (at 167.1884 126.4214) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 167.1884 126.4214) (end 172.67459 120.93521) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 164.3 126.41) (end 164.3 127.66) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 163.6265 128.3335) (end 158.6865 128.3335) (width 0.25) (layer F.Cu) (net 36)) + (via (at 158.6865 128.3335) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 164.3 127.66) (end 163.6265 128.3335) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 152.9 126.41) (end 154.793988 128.303988) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 158.656988 128.303988) (end 158.6865 128.3335) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 154.793988 128.303988) (end 158.656988 128.303988) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 191.05 95.62) (end 192.89285 97.46285) (width 0.25) (layer B.Cu) (net 36)) + (via (at 201.272457 97.46285) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 192.89285 97.46285) (end 201.272457 97.46285) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.45 95.62) (end 201.272457 96.797543) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 201.272457 96.797543) (end 201.272457 97.46285) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 201.272457 101.972457) (end 201.272457 97.46285) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.005399 115.014601) (end 202.005399 115.899399) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 202.4 114.62) (end 202.005399 115.014601) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 175 39.6) (end 175.15001 39.44999) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 172.4742 39.6) (end 175 39.6) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 169.70499 36.83079) (end 172.4742 39.6) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 155.01921 36.83079) (end 169.70499 36.83079) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 181.04999 39.44999) (end 181.5 39.9) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 153.55 38.3) (end 155.01921 36.83079) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 103.2 60.180745) (end 103.2 41.165767) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 103.175 60.205745) (end 103.2 60.180745) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 103.2 41.165767) (end 106.065768 38.3) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 175.15001 39.44999) (end 181.04999 39.44999) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 106.065768 38.3) (end 153.55 38.3) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 201.272457 101.972457) (end 201.272457 102.272457) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 201.272457 102.272457) (end 202.8 103.8) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 202.8 103.8) (end 203.6 104.6) (width 0.25) (layer B.Cu) (net 36)) + (via (at 203.6 110) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 36)) + (segment (start 203.6 104.6) (end 203.6 110) (width 0.25) (layer B.Cu) (net 36)) + (segment (start 203.6 113.42) (end 202.4 114.62) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 203.6 110) (end 203.6 113.42) (width 0.25) (layer F.Cu) (net 36)) + (segment (start 182.4 92.95) (end 182.4 91.62) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC2)) + (segment (start 182.4 91.62) (end 183.3 90.72) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC3)) + (segment (start 171.9 90.72) (end 171.92 90.72) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC4)) + (segment (start 171.92 90.72) (end 174.15 92.95) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC5)) + (segment (start 174.15 92.95) (end 182.4 92.95) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC6)) + (via (at 182.4 92.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37) (tstamp 5F754BC8)) + (segment (start 182.4 54.85) (end 182.4 53.52) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC2)) + (segment (start 182.4 53.52) (end 183.3 52.62) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC3)) + (segment (start 171.9 52.62) (end 171.92 52.62) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC4)) + (segment (start 171.92 52.62) (end 174.15 54.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC5)) + (segment (start 174.15 54.85) (end 182.4 54.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC6)) + (via (at 182.4 54.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37) (tstamp 5F754BC8)) + (segment (start 182.4 73.85) (end 182.4 72.52) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC2)) + (segment (start 182.4 72.52) (end 183.3 71.62) (width 0.25) (layer F.Cu) (net 37) (tstamp 5F754BC3)) + (segment (start 171.9 71.62) (end 171.92 71.62) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC4)) + (segment (start 171.92 71.62) (end 174.15 73.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC5)) + (segment (start 174.15 73.85) (end 182.4 73.85) (width 0.25) (layer B.Cu) (net 37) (tstamp 5F754BC6)) + (via (at 182.4 73.85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37) (tstamp 5F754BC8)) + (segment (start 107.42 61.55) (end 106.224255 62.745745) (width 0.25) (layer F.Cu) (net 37) (status 10)) + (segment (start 103.7 62.745745) (end 93.478815 62.745745) (width 0.25) (layer F.Cu) (net 37) (status 20)) + (via (at 103.7 62.745745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 106.224255 62.745745) (end 103.7 62.745745) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 86.212001) (end 183.955001 84.105001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 90.72) (end 183.3 86.867002) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 86.867002) (end 183.955001 86.212001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 74.7) (end 182.4 73.85) (width 0.25) (layer F.Cu) (net 37)) + (via (at 183.25 64.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 183.955001 65.605001) (end 183.25 64.9) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 71.62) (end 183.955001 70.964999) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 70.964999) (end 183.955001 65.605001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 105.312001) (end 183.955001 94.505001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 105.967002) (end 183.955001 105.312001) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 94.505001) (end 182.4 92.95) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.3 109.82) (end 183.3 105.967002) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 173.779989 111.699989) (end 181.207533 111.699989) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 182.091239 111.028761) (end 181.878761 111.028761) (width 0.25) (layer F.Cu) (net 37)) + (via (at 181.878761 111.028761) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 171.9 109.82) (end 173.779989 111.699989) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 183.3 109.82) (end 182.091239 111.028761) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 181.207533 111.699989) (end 181.878761 111.028761) (width 0.25) (layer B.Cu) (net 37)) + (via (at 173.779989 111.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 182.4 54.85) (end 182.950011 55.400011) (width 0.25) (layer F.Cu) (net 37)) + (via (at 182.950011 61.131673) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 182.950011 55.400011) (end 182.950011 61.131673) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 182.950011 64.600011) (end 182.950011 61.131673) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 183.25 64.9) (end 182.950011 64.600011) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 173.779989 111.625) (end 173.779989 113.454411) (width 0.25) (layer F.Cu) (net 37)) + (via (at 171.969 115.2654) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 173.779989 113.454411) (end 171.969 115.2654) (width 0.25) (layer F.Cu) (net 37)) + (via (at 147.7882 129.354) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 145.734 129.354) (end 145.2 128.82) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 147.7882 129.354) (end 145.734 129.354) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 138.565323 130.933999) (end 138.831761 130.667561) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 133.8 130.07) (end 134.663999 130.933999) (width 0.25) (layer B.Cu) (net 37)) + (via (at 138.831761 130.667561) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 138.8728 130.7086) (end 138.831761 130.667561) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 144.5614 130.7086) (end 138.8728 130.7086) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 145.2 130.07) (end 144.5614 130.7086) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 145.2 128.82) (end 145.2 130.07) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 134.663999 130.933999) (end 138.565323 130.933999) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 133.8 128.82) (end 133.8 130.07) (width 0.25) (layer B.Cu) (net 37)) + (via (at 162.6362 42.5958) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 162.6362 42.5958) (end 166.9034 42.5958) (width 0.25) (layer B.Cu) (net 37)) + (via (at 166.9288 42.5704) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 166.9034 42.5958) (end 166.9288 42.5704) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 168.9354 42.5704) (end 169.0116 42.4942) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 171.9 52.62) (end 170.694399 51.414399) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 166.9288 42.5704) (end 168.9354 42.5704) (width 0.25) (layer F.Cu) (net 37)) + (via (at 169.0116 42.4942) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 170.694399 43.436957) (end 169.751642 42.4942) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 170.694399 51.414399) (end 170.694399 43.436957) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 169.751642 42.4942) (end 169.0116 42.4942) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 155.544253 42.624999) (end 152.723174 39.80392) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 162.6362 42.5958) (end 162.665001 42.624601) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 162.665001 42.624999) (end 155.544253 42.624999) (width 0.25) (layer F.Cu) (net 37)) + (via (at 152.723174 39.80392) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 37)) + (segment (start 162.665001 42.624601) (end 162.665001 42.624999) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 157.833011 129.354) (end 147.7882 129.354) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 171.969 115.2654) (end 171.969 120.236002) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 171.969 120.236002) (end 162.851002 129.354) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 162.851002 129.354) (end 157.833011 129.354) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 152.723174 39.315661) (end 152.723174 39.80392) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 152.607513 39.2) (end 152.723174 39.315661) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 141.90371 39.2) (end 148.850403 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 137.09629 39.2) (end 137.397911 38.898379) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 105.802177 39.2) (end 137.09629 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 137.397911 38.898379) (end 141.602089 38.898379) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 103.7 41.302177) (end 105.802177 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 151.786274 39.11199) (end 151.874284 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 148.938413 39.11199) (end 151.786274 39.11199) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 148.850403 39.2) (end 148.938413 39.11199) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 151.874284 39.2) (end 152.607513 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 141.602089 38.898379) (end 141.90371 39.2) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 103.7 62.745745) (end 103.7 41.302177) (width 0.25) (layer B.Cu) (net 37)) + (segment (start 183.25 83.4) (end 183.6814 83.8314) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.6814 83.8314) (end 183.5 83.65) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 81.4942) (end 183.25 83.4) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 81.4942) (end 183.25 74.7) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.25 81.65) (end 183.25 81.4942) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 183.955001 84.105001) (end 183.6814 83.8314) (width 0.25) (layer F.Cu) (net 37)) + (segment (start 152.55 50.41) (end 152.57 50.41) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 163.3 90.64) (end 163.3 89.31) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC2)) + (segment (start 163.3 89.31) (end 164.2 88.41) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC3)) + (segment (start 152.8 88.41) (end 152.82 88.41) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 152.82 88.41) (end 155.05 90.64) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC5)) + (segment (start 155.05 90.64) (end 163.3 90.64) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC6)) + (via (at 163.3 90.64) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38) (tstamp 5F754BC8)) + (segment (start 163.4 71.44) (end 163.4 70.11) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC2)) + (segment (start 163.4 70.11) (end 164.3 69.21) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC3)) + (segment (start 152.9 69.21) (end 152.92 69.21) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 152.92 69.21) (end 155.15 71.44) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC5)) + (segment (start 155.15 71.44) (end 163.4 71.44) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC6)) + (via (at 163.4 71.44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38) (tstamp 5F754BC8)) + (segment (start 163.4 109.54) (end 163.4 108.21) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC2)) + (segment (start 163.4 108.21) (end 164.3 107.31) (width 0.25) (layer F.Cu) (net 38) (tstamp 5F754BC3)) + (segment (start 152.9 107.31) (end 152.92 107.31) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC4)) + (segment (start 155.15 109.54) (end 163.4 109.54) (width 0.25) (layer B.Cu) (net 38) (tstamp 5F754BC6)) + (via (at 163.4 109.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38) (tstamp 5F754BC8)) + (via (at 104.3 64.575) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 106.935 64.575) (end 107.42 64.09) (width 0.25) (layer F.Cu) (net 38) (status 30)) + (segment (start 104.3 64.575) (end 106.935 64.575) (width 0.25) (layer F.Cu) (net 38) (status 20)) + (segment (start 94.18956 64.575) (end 93.478815 65.285745) (width 0.25) (layer F.Cu) (net 38) (status 20)) + (segment (start 104.3 64.575) (end 94.18956 64.575) (width 0.25) (layer F.Cu) (net 38)) + (via (at 150.25 52.265) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 152.395 50.12) (end 152.9 50.12) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 150.25 52.265) (end 152.395 50.12) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 164.955001 106.654999) (end 164.3 107.31) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.955001 92.295001) (end 164.955001 106.654999) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 163.3 90.64) (end 164.955001 92.295001) (width 0.25) (layer F.Cu) (net 38)) + (via (at 165 78.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 165 73.04) (end 163.4 71.44) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165 78.54) (end 165 73.04) (width 0.25) (layer F.Cu) (net 38)) + (via (at 151.75 63.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 152.9 69.21) (end 151.75 68.06) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 151.75 68.06) (end 151.75 63.54) (width 0.25) (layer B.Cu) (net 38)) + (via (at 153 109.04) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 153 107.41) (end 152.9 107.31) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 153 109.04) (end 153 107.41) (width 0.25) (layer B.Cu) (net 38)) + (via (at 165 81.540021) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 165 87.61) (end 165 81.540021) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.3 88.31) (end 165 87.61) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165 78.54) (end 165 81.540021) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.25 63.04) (end 151.75 63.54) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.25 56.64) (end 152.25 63.04) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.64999 56.24001) (end 152.25 56.64) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.9 55.99) (end 152.64999 56.24001) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.55 55.99) (end 152.9 55.99) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165.775001 54.764999) (end 164.55 55.99) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 164.3 50.12) (end 165.775001 51.595001) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 165.775001 51.595001) (end 165.775001 54.764999) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.9 54.915) (end 150.25 52.265) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 152.9 55.99) (end 152.9 54.915) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 151.99998 41.690505) (end 152.070275 41.62021) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 151.99998 47.96998) (end 151.99998 41.690505) (width 0.25) (layer B.Cu) (net 38)) + (via (at 152.070275 41.62021) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 152.9 50.12) (end 152.9 48.87) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.9 48.87) (end 151.99998 47.96998) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 153 109.04) (end 153.4975 109.5375) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 155.1475 109.5375) (end 155.15 109.54) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 153.4975 109.5375) (end 155.1475 109.5375) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 114.387872 135.789305) (end 119.960695 135.789305) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 113.419376 134.820809) (end 114.387872 135.789305) (width 0.25) (layer B.Cu) (net 38)) + (via (at 123.5 133.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 119.960695 135.789305) (end 121.210695 135.789305) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 121.210695 135.789305) (end 123.5 133.5) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 123.5 132.801203) (end 124.430931 131.870272) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 123.5 133.5) (end 123.5 132.801203) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 141.71731 39.650011) (end 149.036803 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 137.28269 39.650011) (end 137.584311 39.34839) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 151.912883 39.87501) (end 152.061699 39.87501) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.070275 41.62021) (end 152.070275 39.883586) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 104.3 64.575) (end 104.3 41.388592) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 149.124813 39.562001) (end 151.599874 39.562001) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 104.3 41.388592) (end 106.038581 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 149.036803 39.650011) (end 149.124813 39.562001) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 137.584311 39.34839) (end 141.415689 39.34839) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 141.415689 39.34839) (end 141.71731 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 106.038581 39.650011) (end 137.28269 39.650011) (width 0.25) (layer B.Cu) (net 38)) + (via (at 152.061699 39.87501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 38)) + (segment (start 151.599874 39.562001) (end 151.912883 39.87501) (width 0.25) (layer B.Cu) (net 38)) + (segment (start 152.070275 39.883586) (end 152.061699 39.87501) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 126.2 130.101203) (end 124.430931 131.870272) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 129.635595 114.892799) (end 126.2 118.328394) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 135.537001 114.892799) (end 129.635595 114.892799) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 135.9772 114.4526) (end 135.537001 114.892799) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 150.1519 114.4526) (end 135.9772 114.4526) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 153 111.6045) (end 150.1519 114.4526) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 126.2 118.328394) (end 126.2 130.101203) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 153 109.04) (end 153 111.6045) (width 0.25) (layer F.Cu) (net 38)) + (segment (start 144.3 54.9) (end 144.3 53.57) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC2)) + (segment (start 144.3 53.57) (end 145.2 52.67) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC3)) + (via (at 144.3 54.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39) (tstamp 5F754BC8)) + (segment (start 144.3 73.9) (end 144.3 72.57) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC2)) + (segment (start 144.3 72.57) (end 145.2 71.67) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC3)) + (segment (start 133.8 71.67) (end 133.82 71.67) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC4)) + (segment (start 133.82 71.67) (end 136.05 73.9) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC5)) + (segment (start 136.05 73.9) (end 144.3 73.9) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC6)) + (via (at 144.3 73.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39) (tstamp 5F754BC8)) + (segment (start 144.3 111.95) (end 144.3 110.62) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC2)) + (segment (start 144.3 110.62) (end 145.2 109.72) (width 0.25) (layer F.Cu) (net 39) (tstamp 5F754BC3)) + (segment (start 133.8 109.72) (end 133.82 109.72) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC4)) + (segment (start 133.82 109.72) (end 136.05 111.95) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC5)) + (segment (start 136.05 111.95) (end 144.3 111.95) (width 0.25) (layer B.Cu) (net 39) (tstamp 5F754BC6)) + (via (at 144.3 111.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39) (tstamp 5F754BC8)) + (segment (start 105.199999 66.199999) (end 105 66) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 107.42 66.63) (end 105.63 66.63) (width 0.25) (layer F.Cu) (net 39) (status 10)) + (segment (start 105.63 66.63) (end 105.199999 66.199999) (width 0.25) (layer F.Cu) (net 39)) + (via (at 105 66) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 95.754549 65.550011) (end 104.550011 65.550011) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 93.478815 67.825745) (end 95.754549 65.550011) (width 0.25) (layer F.Cu) (net 39) (status 10)) + (segment (start 104.800001 65.800001) (end 105 66) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 104.550011 65.550011) (end 104.800001 65.800001) (width 0.25) (layer F.Cu) (net 39)) + (via (at 133.25 111.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 133.25 110.27) (end 133.8 109.72) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.25 111.3) (end 133.25 110.27) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 145.855001 89.964999) (end 145.2 90.62) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 75.455001) (end 145.855001 89.964999) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 144.3 73.9) (end 145.855001 75.455001) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 70.964999) (end 145.2 71.62) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 56.455001) (end 145.855001 70.964999) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 144.3 54.9) (end 145.855001 56.455001) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 143.767158 92.52499) (end 144.05 92.52499) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 135.40499 92.52499) (end 143.767158 92.52499) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.55 90.67) (end 135.40499 92.52499) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 144.95 90.67) (end 144.05 91.57) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 109.064999) (end 145.855001 94.329991) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 144.05 91.57) (end 144.05 92.52499) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.2 109.72) (end 145.855001 109.064999) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 145.855001 94.329991) (end 144.05 92.52499) (width 0.25) (layer F.Cu) (net 39)) + (via (at 144.05 92.52499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 132.775355 50.245355) (end 132.775355 45.504242) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 132.775355 45.504242) (end 132.975354 45.304243) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.8 51.27) (end 132.775355 50.245355) (width 0.25) (layer B.Cu) (net 39)) + (via (at 132.975354 45.304243) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 133.8 52.52) (end 133.8 51.27) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133 45.279597) (end 132.975354 45.304243) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 132.975354 42.874646) (end 133.154739 42.695261) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 132.975354 45.304243) (end 132.975354 42.874646) (width 0.25) (layer F.Cu) (net 39)) + (via (at 133.154739 42.695261) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (via (at 88.273 133.285) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 132.75 111.4) (end 130.773547 113.376453) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 130.773547 113.376453) (end 130.773547 113.628547) (width 0.25) (layer F.Cu) (net 39)) + (via (at 130.773547 113.628547) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 39)) + (segment (start 144.2725 54.9275) (end 144.3 54.9) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 136.0575 54.9275) (end 144.2725 54.9275) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 133.8 52.67) (end 136.0575 54.9275) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 93.636229 140.896345) (end 91 138.260116) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 95.12595 140.896345) (end 93.636229 140.896345) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 91 138.260116) (end 91 137) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 88.273 134.273) (end 88.273 133.285) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 91 137) (end 88.273 134.273) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 88.273 132.176605) (end 89.42595 131.023655) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 88.273 133.285) (end 88.273 132.176605) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 132.85 111.3) (end 133.25 111.3) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 132.75 111.4) (end 132.85 111.3) (width 0.25) (layer F.Cu) (net 39)) + (segment (start 105 41.325002) (end 106.174991 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 107.948773 40.150011) (end 130.609489 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.609489 40.150011) (end 133.154739 42.695261) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 106.898239 40.142999) (end 107.941761 40.142999) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 107.941761 40.142999) (end 107.948773 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 106.891227 40.150011) (end 106.898239 40.142999) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 105 66) (end 105 41.325002) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 106.174991 40.150011) (end 106.891227 40.150011) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 97.918502 122.531102) (end 89.42595 131.023655) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 98.624805 121.824799) (end 97.918502 122.531102) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 105.175201 121.824799) (end 98.624805 121.824799) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 111.901602 116.501602) (end 109.403204 119) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 109.403204 119) (end 108 119) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.031602 116.501602) (end 111.901602 116.501602) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.773547 115.759657) (end 130.031602 116.501602) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 108 119) (end 105.175201 121.824799) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 130.773547 113.628547) (end 130.773547 115.759657) (width 0.25) (layer B.Cu) (net 39)) + (segment (start 91.877307 51.39) (end 92.18 51.39) (width 0.25) (layer F.Cu) (net 40) (status 30)) + (via (at 105.6 51.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 98.153565 67.600055) (end 102.800055 67.600055) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.7 68.79962) (end 96.954 68.79962) (width 0.25) (layer F.Cu) (net 40) (status 30)) + (segment (start 96.954 68.79962) (end 98.153565 67.600055) (width 0.25) (layer F.Cu) (net 40) (status 10)) + (segment (start 102.800055 67.600055) (end 102.900001 67.700001) (width 0.25) (layer F.Cu) (net 40)) + (via (at 96.1 51.39) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 92.18 51.39) (end 96.1 51.39) (width 0.25) (layer F.Cu) (net 40) (status 10)) + (segment (start 105.59 51.39) (end 105.6 51.4) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.1 51.39) (end 105.59 51.39) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.05 51.44) (end 96.1 51.39) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 102.900001 67.700001) (end 103.1 67.9) (width 0.25) (layer F.Cu) (net 40)) + (via (at 96.05 67.805847) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 96.05 67.805847) (end 96.05 51.44) (width 0.25) (layer B.Cu) (net 40)) + (via (at 103.1 67.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 40)) + (segment (start 105.6 51.4) (end 106.785745 52.585745) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 106.785745 52.585745) (end 108.718815 52.585745) (width 0.25) (layer B.Cu) (net 40) (status 20)) + (segment (start 96.05 68.364) (end 96.05 67.805847) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.7 68.79962) (end 96.48562 68.79962) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 96.48562 68.79962) (end 96.05 68.364) (width 0.25) (layer F.Cu) (net 40)) + (segment (start 101.277771 79.613466) (end 100.579272 80.311965) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 101.602773 77.682445) (end 101.602773 79.288464) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 102.803501 69.535499) (end 102.803501 76.481717) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 103.53938 68.79962) (end 102.803501 69.535499) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 102.803501 76.481717) (end 101.602773 77.682445) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 104.3 68.79962) (end 103.53938 68.79962) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 101.602773 79.288464) (end 101.277771 79.613466) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 103.1 68.302) (end 103.1 67.9) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 103.59762 68.79962) (end 103.1 68.302) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 104.3 68.79962) (end 103.59762 68.79962) (width 0.25) (layer B.Cu) (net 40)) + (segment (start 92.18 41.23) (end 105.330006 41.23) (width 0.25) (layer F.Cu) (net 41) (status 10)) + (segment (start 105.330006 41.23) (end 105.500007 41.400001) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 105.500007 41.400001) (end 105.700006 41.6) (width 0.25) (layer F.Cu) (net 41)) + (via (at 105.700006 41.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 108.718815 42.425745) (end 106.525751 42.425745) (width 0.25) (layer B.Cu) (net 41) (status 10)) + (segment (start 106.525751 42.425745) (end 105.900005 41.799999) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 105.900005 41.799999) (end 105.700006 41.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 107.9 78.6) (end 108.35 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 113.35 78.6) (end 114 79.25) (width 0.25) (layer B.Cu) (net 41)) + (via (at 114 79.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 107.9 78.6) (end 113.35 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.5 78.6) (end 107.9 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.5 73.95) (end 110.5 78.6) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 108.718815 42.425745) (end 110.970095 44.677025) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.970095 73.479905) (end 110.5 73.95) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 110.970095 44.677025) (end 110.970095 73.479905) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 107.95 85.625) (end 109.125 85.625) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 109.125 85.625) (end 112.475 85.625) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 109.374996 87.375) (end 109.4 87.400004) (width 0.25) (layer F.Cu) (net 41)) + (via (at 109.4 87.400004) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 107.95 87.375) (end 109.374996 87.375) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 109.4 85.625) (end 109.4 87.400004) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 109.125 85.625) (end 109.4 85.625) (width 0.25) (layer B.Cu) (net 41)) + (segment (start 113.3435 83.30438) (end 112.522 83.30438) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 114 82.64788) (end 113.3435 83.30438) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 114 79.25) (end 114 82.64788) (width 0.25) (layer F.Cu) (net 41)) + (via (at 112.475 85.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 41)) + (segment (start 112.522 85.578) (end 112.475 85.625) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 112.522 83.30438) (end 112.522 85.578) (width 0.25) (layer F.Cu) (net 41)) + (segment (start 91.587307 53.93) (end 92.18 53.93) (width 0.25) (layer F.Cu) (net 42) (status 30)) + (segment (start 101.6 68.69962) (end 101.7 68.79962) (width 0.25) (layer B.Cu) (net 42) (status 30)) + (segment (start 92.18 53.93) (end 101.7 53.93) (width 0.25) (layer F.Cu) (net 42) (status 10)) + (via (at 101.2 53.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 42)) + (segment (start 105.430018 53.93) (end 101.7 53.93) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 105.700018 54.2) (end 105.430018 53.93) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 106.625763 55.125745) (end 105.900017 54.399999) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 101.2 68.79962) (end 101.2 53.93) (width 0.25) (layer B.Cu) (net 42) (status 10)) + (segment (start 108.718815 55.125745) (end 106.625763 55.125745) (width 0.25) (layer B.Cu) (net 42) (status 10)) + (segment (start 105.900017 54.399999) (end 105.700018 54.2) (width 0.25) (layer B.Cu) (net 42)) + (via (at 105.700018 54.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 42)) + (segment (start 102.796902 68.79962) (end 102.826022 68.7705) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 101.7 68.79962) (end 102.796902 68.79962) (width 0.25) (layer B.Cu) (net 42)) + (via (at 102.826022 68.7705) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 42)) + (segment (start 101.346 68.7705) (end 102.826022 68.7705) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 100.579272 78.061965) (end 100.579272 69.537228) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 100.579272 69.537228) (end 101.346 68.7705) (width 0.25) (layer B.Cu) (net 42)) + (segment (start 99.413 68.1) (end 102.438364 68.1) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 102.826022 68.487658) (end 102.826022 68.7705) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 102.438364 68.1) (end 102.826022 68.487658) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 99.2 68.79962) (end 99.2 68.313) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 99.2 68.313) (end 99.413 68.1) (width 0.25) (layer F.Cu) (net 42)) + (segment (start 107.46 46.2) (end 107.47 46.21) (width 0.25) (layer F.Cu) (net 43) (status 30)) + (segment (start 105.7 46.2) (end 107.46 46.2) (width 0.25) (layer F.Cu) (net 43) (status 20)) + (segment (start 104.394255 47.505745) (end 105.7 46.2) (width 0.25) (layer F.Cu) (net 43)) + (segment (start 93.478815 47.505745) (end 104.394255 47.505745) (width 0.25) (layer F.Cu) (net 43) (status 10)) + (segment (start 89.000001 79.750001) (end 90 80.75) (width 0.25) (layer B.Cu) (net 43) (status 20)) + (segment (start 88.674999 79.424999) (end 89.000001 79.750001) (width 0.25) (layer B.Cu) (net 43)) + (segment (start 88.674999 50.746239) (end 88.674999 79.424999) (width 0.25) (layer B.Cu) (net 43)) + (segment (start 91.658239 47.762999) (end 88.674999 50.746239) (width 0.25) (layer B.Cu) (net 43)) + (segment (start 93.221561 47.762999) (end 91.658239 47.762999) (width 0.25) (layer B.Cu) (net 43) (status 10)) + (segment (start 93.478815 47.505745) (end 93.221561 47.762999) (width 0.25) (layer B.Cu) (net 43) (status 30)) + (via (at 143.3178 131.8262) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 129.7796 122.098) (end 129.7796 127.4828) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 143.3178 131.8262) (end 134.123 131.8262) (width 0.25) (layer F.Cu) (net 44)) + (via (at 132.6244 130.3276) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 134.123 131.8262) (end 132.6244 130.3276) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 129.7796 127.4828) (end 132.6244 130.3276) (width 0.25) (layer B.Cu) (net 44)) + (via (at 157.491 128.82899) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 165.6 125.12) (end 161.86149 128.85851) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 157.52052 128.85851) (end 157.491 128.82899) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 146.31501 128.82899) (end 157.491 128.82899) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 143.3178 131.8262) (end 146.31501 128.82899) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 154.86399 128.82899) (end 157.491 128.82899) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 151.6 125.565) (end 154.86399 128.82899) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 151.6 123.87) (end 151.6 125.565) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 165.6 123.87) (end 165.6 125.12) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 161.86149 128.85851) (end 157.52052 128.85851) (width 0.25) (layer B.Cu) (net 44)) + (via (at 129.7796 122.098) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 44)) + (segment (start 127.55 121.6) (end 129.2816 121.6) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 129.2816 121.6) (end 129.7796 122.098) (width 0.25) (layer F.Cu) (net 44)) + (segment (start 129.7796 122.098) (end 129.2816 121.6) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 129.2816 121.6) (end 127.55 121.6) (width 0.25) (layer B.Cu) (net 44)) + (segment (start 106.224255 42.425745) (end 107.42 41.23) (width 0.25) (layer F.Cu) (net 45) (status 20)) + (segment (start 93.478815 42.425745) (end 106.224255 42.425745) (width 0.25) (layer F.Cu) (net 45) (status 10)) + (segment (start 92.18 56.47) (end 105.469992 56.47) (width 0.25) (layer F.Cu) (net 46) (status 10)) + (segment (start 105.469992 56.47) (end 105.499993 56.500001) (width 0.25) (layer F.Cu) (net 46)) + (segment (start 106.665737 57.665745) (end 105.899991 56.899999) (width 0.25) (layer B.Cu) (net 46)) + (segment (start 105.499993 56.500001) (end 105.699992 56.7) (width 0.25) (layer F.Cu) (net 46)) + (segment (start 105.899991 56.899999) (end 105.699992 56.7) (width 0.25) (layer B.Cu) (net 46)) + (segment (start 108.718815 57.665745) (end 106.665737 57.665745) (width 0.25) (layer B.Cu) (net 46) (status 10)) + (via (at 105.699992 56.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 46)) + (via (at 94.8 70.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 47)) + (segment (start 92.18 43.77) (end 94.7 43.77) (width 0.25) (layer F.Cu) (net 47) (status 10)) + (segment (start 94.7 43.77) (end 94.97 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 105.47 43.77) (end 105.500001 43.800001) (width 0.25) (layer F.Cu) (net 47)) + (via (at 95.1 44.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 47)) + (segment (start 106.665745 44.965745) (end 105.899999 44.199999) (width 0.25) (layer B.Cu) (net 47)) + (segment (start 105.500001 43.800001) (end 105.7 44) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.1 44.2) (end 94.8 44.5) (width 0.25) (layer B.Cu) (net 47)) + (via (at 105.7 44) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 47)) + (segment (start 105.899999 44.199999) (end 105.7 44) (width 0.25) (layer B.Cu) (net 47)) + (segment (start 108.718815 44.965745) (end 106.665745 44.965745) (width 0.25) (layer B.Cu) (net 47) (status 10)) + (segment (start 94.8 44.5) (end 94.8 70.6) (width 0.25) (layer B.Cu) (net 47)) + (segment (start 94.254 74.49962) (end 94 74.49962) (width 0.25) (layer F.Cu) (net 47) (status 30)) + (segment (start 94.8215 73.93212) (end 94.254 74.49962) (width 0.25) (layer F.Cu) (net 47) (status 20)) + (segment (start 94.8215 73.72112) (end 94.8215 73.93212) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 94.8 73.69962) (end 94.8215 73.72112) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 94.8 70.6) (end 94.8 73.69962) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.1 43.792) (end 95.078 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.1 44.2) (end 95.1 43.792) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 94.7 43.77) (end 95.078 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 95.078 43.77) (end 105.47 43.77) (width 0.25) (layer F.Cu) (net 47)) + (segment (start 96.7 69.80038) (end 96.7 74.6) (width 0.25) (layer F.Cu) (net 48) (status 30)) + (segment (start 96.7 69.80038) (end 96.7 74.6) (width 0.25) (layer B.Cu) (net 48) (status 30)) + (segment (start 99.2 74.56) (end 99.24 74.6) (width 0.25) (layer F.Cu) (net 49) (status 30)) + (segment (start 99.2 69.80038) (end 99.2 74.56) (width 0.25) (layer F.Cu) (net 49) (status 30)) + (segment (start 99.2 74.56) (end 99.24 74.6) (width 0.25) (layer B.Cu) (net 49) (status 30)) + (segment (start 99.2 69.80038) (end 99.2 74.56) (width 0.25) (layer B.Cu) (net 49) (status 30)) + (segment (start 101.7 74.52) (end 101.78 74.6) (width 0.25) (layer F.Cu) (net 50) (status 30)) + (segment (start 101.7 69.80038) (end 101.7 74.52) (width 0.25) (layer F.Cu) (net 50) (status 30)) + (segment (start 101.7 74.52) (end 101.78 74.6) (width 0.25) (layer B.Cu) (net 50) (status 30)) + (segment (start 101.7 69.80038) (end 101.7 74.52) (width 0.25) (layer B.Cu) (net 50) (status 30)) + (segment (start 104.3 74.58) (end 104.32 74.6) (width 0.25) (layer F.Cu) (net 51) (status 30)) + (segment (start 104.3 69.80038) (end 104.3 74.58) (width 0.25) (layer F.Cu) (net 51) (status 30)) + (segment (start 104.3 74.58) (end 104.32 74.6) (width 0.25) (layer B.Cu) (net 51) (status 30)) + (segment (start 104.3 69.80038) (end 104.3 74.58) (width 0.25) (layer B.Cu) (net 51) (status 30)) + (segment (start 180.607 131.623) (end 178.065 131.623) (width 0.25) (layer B.Cu) (net 52)) + (via (at 178.065 131.623) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 52)) + (segment (start 184.6 126.38) (end 184.6 127.63) (width 0.25) (layer B.Cu) (net 52)) + (segment (start 184.6 127.63) (end 180.607 131.623) (width 0.25) (layer B.Cu) (net 52)) + (via (at 128.6828 119.02) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 52)) + (segment (start 170.6 128.4995) (end 170.6 126.38) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 178.065 131.623) (end 173.7235 131.623) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 173.7235 131.623) (end 170.6 128.4995) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 170.6 128.5485) (end 169.794499 129.354001) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 170.6 126.38) (end 170.6 128.5485) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 169.794499 129.354001) (end 154.064003 129.354001) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 154.064003 129.354001) (end 145.614202 120.9042) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 145.614202 120.9042) (end 130.567 120.9042) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 130.567 120.9042) (end 128.6828 119.02) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 127.58 119.02) (end 128.6828 119.02) (width 0.25) (layer F.Cu) (net 52)) + (segment (start 128.6828 119.02) (end 127.58 119.02) (width 0.25) (layer B.Cu) (net 52)) + (segment (start 108.55 97) (end 108.7 97) (width 0.25) (layer B.Cu) (net 53) (status 30)) + (segment (start 107 98.55) (end 107 102) (width 0.25) (layer B.Cu) (net 53) (status 20)) + (segment (start 108.55 97) (end 107.775 97.775) (width 0.25) (layer F.Cu) (net 53)) + (segment (start 108.775 97) (end 108.55 97) (width 0.25) (layer F.Cu) (net 53)) + (segment (start 107 98.55) (end 107.775 97.775) (width 0.25) (layer B.Cu) (net 53)) + (via (at 107.775 97.775) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 53)) + (segment (start 107.775 97.775) (end 108.55 97) (width 0.25) (layer B.Cu) (net 53)) + (segment (start 114.55 55.12) (end 114.57 55.12) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 125.55 95.6) (end 125.55 94.27) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC2)) + (segment (start 125.55 94.27) (end 126.45 93.37) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC3)) + (segment (start 115.05 93.37) (end 115.07 93.37) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 115.07 93.37) (end 117.3 95.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC5)) + (segment (start 117.3 95.6) (end 125.55 95.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC6)) + (via (at 125.55 95.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54) (tstamp 5F754BC8)) + (segment (start 125.3 76.6) (end 125.3 75.27) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC2)) + (segment (start 125.3 75.27) (end 126.2 74.37) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC3)) + (segment (start 114.8 74.37) (end 114.82 74.37) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 114.82 74.37) (end 117.05 76.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC5)) + (segment (start 117.05 76.6) (end 125.3 76.6) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC6)) + (via (at 125.3 76.6) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54) (tstamp 5F754BC8)) + (segment (start 125.3 114.45) (end 125.3 113.12) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC2)) + (segment (start 125.3 113.12) (end 126.2 112.22) (width 0.25) (layer F.Cu) (net 54) (tstamp 5F754BC3)) + (segment (start 114.8 112.22) (end 114.82 112.22) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC4)) + (segment (start 114.82 112.22) (end 117.05 114.45) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC5)) + (segment (start 117.05 114.45) (end 125.3 114.45) (width 0.25) (layer B.Cu) (net 54) (tstamp 5F754BC6)) + (via (at 125.3 114.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54) (tstamp 5F754BC8)) + (segment (start 95.3 67.280659) (end 96.130626 66.450033) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 106.658001 68.408001) (end 107.42 69.17) (width 0.25) (layer F.Cu) (net 54) (status 20)) + (segment (start 93.478815 70.365745) (end 95.3 68.54456) (width 0.25) (layer F.Cu) (net 54) (status 10)) + (segment (start 95.3 68.54456) (end 95.3 67.280659) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 96.130626 66.450033) (end 103.963219 66.450033) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 103.963219 66.450033) (end 105.921187 68.408001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 105.921187 68.408001) (end 106.658001 68.408001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.825 110.325) (end 111 110.5) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 107 107) (end 109.5 107) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 109.5 107) (end 110.825 105.675) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 105.675) (end 110.825 110.325) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 112.405 90.825) (end 110.825 90.825) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.8 93.22) (end 112.405 90.825) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 90.825) (end 110.825 105.675) (width 0.25) (layer B.Cu) (net 54)) + (via (at 114.75 56.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 114.75 55.17) (end 114.8 55.12) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.75 56.5) (end 114.75 55.17) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 89.79999) (end 110.77501 89.75) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.825 90.825) (end 110.825 89.79999) (width 0.25) (layer B.Cu) (net 54)) + (via (at 110.77501 89.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (via (at 111.75 112.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111 110.5) (end 111 111.5) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 111 111.5) (end 111.75 112.25) (width 0.25) (layer B.Cu) (net 54)) + (via (at 114.25 113.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.75 112.25) (end 113.25 113.75) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 113.25 113.75) (end 114.25 113.75) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 114.25 112.77) (end 114.8 112.22) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.25 113.75) (end 114.25 112.77) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 111.644437 71.064437) (end 111.644437 69.155563) (width 0.25) (layer B.Cu) (net 54)) + (via (at 111.649995 69.150005) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.644437 69.155563) (end 111.649995 69.150005) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.490724 69.150005) (end 110.445094 69.104375) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 111.649995 69.150005) (end 110.490724 69.150005) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 107.42 69.17) (end 110.379469 69.17) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 110.379469 69.17) (end 110.445094 69.104375) (width 0.25) (layer B.Cu) (net 54)) + (via (at 110.445094 69.104375) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.644437 74.22) (end 111.644437 71.064437) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.8 74.22) (end 111.644437 74.22) (width 0.25) (layer B.Cu) (net 54)) + (via (at 111.2 74.35) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 54)) + (segment (start 111.33 74.22) (end 111.2 74.35) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 111.644437 74.22) (end 111.33 74.22) (width 0.25) (layer B.Cu) (net 54)) + (segment (start 114.75 56.905001) (end 114.75 56.5) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 126.2 55.12) (end 124.414999 56.905001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 124.414999 56.905001) (end 114.75 56.905001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 114.75 56.9) (end 114.75 56.5) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 112.1 59.55) (end 114.75 56.9) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 111.649995 69.150005) (end 111.649995 64.550005) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 111.649995 64.550005) (end 112.1 64.1) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 112.1 64.1) (end 112.1 59.55) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.77501 89.75) (end 110.975009 89.550001) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.77501 74.77499) (end 111.2 74.35) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.77501 85.825184) (end 110.77501 74.77499) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.975009 86.025183) (end 110.77501 85.825184) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 110.975009 89.550001) (end 110.975009 86.025183) (width 0.25) (layer F.Cu) (net 54)) + (segment (start 106.224255 55.125745) (end 107.42 53.93) (width 0.25) (layer F.Cu) (net 55) (status 20)) + (segment (start 93.478815 55.125745) (end 98.374255 55.125745) (width 0.25) (layer F.Cu) (net 55) (status 10)) + (segment (start 98.874255 55.125745) (end 101.874255 55.125745) (width 0.25) (layer F.Cu) (net 55) (tstamp 5D8DA161)) + (segment (start 101.874255 55.125745) (end 106.224255 55.125745) (width 0.25) (layer F.Cu) (net 55) (tstamp 5D8DA17D)) + (via (at 101.874255 55.125745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 55)) + (segment (start 98.374255 55.125745) (end 98.874255 55.125745) (width 0.25) (layer F.Cu) (net 55) (tstamp 5D8DA43A)) + (segment (start 104.82499 75.609792) (end 104.82499 84.838178) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.2 73.965218) (end 105.343501 74.108719) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.2 68.225618) (end 105.2 73.965218) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.29999 89.83642) (end 93.825001 101.311409) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 101.874255 55.125745) (end 101.874255 64.899873) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 93.825001 101.311409) (end 93.825001 105.674999) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 93.499999 106.000001) (end 92.5 107) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.343501 74.108719) (end 105.343501 75.091281) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.29999 85.313178) (end 105.29999 89.83642) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 105.343501 75.091281) (end 104.82499 75.609792) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 101.874255 64.899873) (end 105.2 68.225618) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 104.82499 84.838178) (end 105.29999 85.313178) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 93.825001 105.674999) (end 93.499999 106.000001) (width 0.25) (layer B.Cu) (net 55)) + (segment (start 106.224255 52.585745) (end 107.42 51.39) (width 0.25) (layer F.Cu) (net 56) (status 20)) + (segment (start 93.478815 52.585745) (end 98.514255 52.585745) (width 0.25) (layer F.Cu) (net 56) (status 10)) + (segment (start 98.514255 52.585745) (end 106.224255 52.585745) (width 0.25) (layer F.Cu) (net 56) (tstamp 5D8DA43D)) + (via (at 98.514255 52.585745) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 56)) + (segment (start 93.499999 101.000001) (end 92.5 102) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 101.37501 93.12499) (end 93.499999 101.000001) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.514255 52.868587) (end 98.216499 53.166343) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.514255 52.585745) (end 98.514255 52.868587) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.216499 53.166343) (end 98.216499 81.404784) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 101.37501 84.563295) (end 101.37501 93.12499) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 98.216499 81.404784) (end 101.37501 84.563295) (width 0.25) (layer B.Cu) (net 56)) + (segment (start 102.3 80.7) (end 102.7 80.3) (width 0.25) (layer F.Cu) (net 57) (status 30)) + (segment (start 100.2 85.3) (end 99.8 85.3) (width 0.25) (layer B.Cu) (net 57) (status 30)) + (segment (start 100.2 85.3) (end 99.8 85.3) (width 0.25) (layer F.Cu) (net 57) (status 30)) + (segment (start 102.7 82.8) (end 100.2 85.3) (width 0.25) (layer F.Cu) (net 57) (status 20)) + (segment (start 102.7 80.3) (end 102.7 82.8) (width 0.25) (layer F.Cu) (net 57) (status 10)) + (segment (start 99.8 85.3) (end 99.8 87.75) (width 0.25) (layer F.Cu) (net 57) (status 30)) + (segment (start 94 81.25) (end 91.7 83.55) (width 0.25) (layer F.Cu) (net 58) (status 20)) + (segment (start 94 75.50038) (end 94 81.25) (width 0.25) (layer F.Cu) (net 58) (status 10)) + (segment (start 91.3 83.55) (end 91.3 89.5) (width 0.25) (layer F.Cu) (net 58) (status 30)) + (segment (start 91.7 83.55) (end 91.3 83.55) (width 0.25) (layer F.Cu) (net 58) (status 30)) + (segment (start 92.87501 82.37499) (end 91.7 83.55) (width 0.25) (layer F.Cu) (net 58) (status 20)) + (segment (start 100.031029 82.37499) (end 92.87501 82.37499) (width 0.25) (layer F.Cu) (net 58)) + (segment (start 101.602773 80.803246) (end 100.031029 82.37499) (width 0.25) (layer F.Cu) (net 58)) + (segment (start 101.602773 79.197227) (end 101.602773 80.803246) (width 0.25) (layer F.Cu) (net 58)) + (segment (start 102.7 78.1) (end 101.602773 79.197227) (width 0.25) (layer F.Cu) (net 58) (status 10)) + (via (at 117.5 87.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 117.5 87.5) (end 114.999994 84.999994) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 114.999994 84.999994) (end 114.999994 83.8) (width 0.25) (layer B.Cu) (net 59)) + (via (at 114.999994 83.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 122.7 60.375) (end 122.125 60.375) (width 0.25) (layer F.Cu) (net 59)) + (via (at 124.6 59.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 122.7 60.375) (end 123.725 60.375) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 123.725 60.375) (end 124.6 59.5) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 124.6 59.5) (end 124.15 59.05) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 123.125 59.05) (end 122.7 58.625) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 124.15 59.05) (end 123.125 59.05) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 118 67.7) (end 119.25 66.45) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 114.999994 81.667164) (end 120.25 76.417158) (width 0.25) (layer F.Cu) (net 59)) + (via (at 122.25 66.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 114.999994 83.8) (end 114.999994 81.667164) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 120.25 72.365002) (end 118 70.115002) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 119.25 66.45) (end 122.25 66.45) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 118 70.115002) (end 118 67.7) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 120.25 76.417158) (end 120.25 72.365002) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.05 123.255) (end 111.245 123.255) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 110.261732 123.255) (end 109.4 124.116732) (width 0.25) (layer B.Cu) (net 59)) + (via (at 109.4 124.116732) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 111.05 123.255) (end 110.261732 123.255) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 109.616732 124.116732) (end 109.4 124.116732) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.05 125.005) (end 110.505 125.005) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 110.505 125.005) (end 109.616732 124.116732) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 125.163188 59.5) (end 124.6 59.5) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 125.9 60.236812) (end 125.163188 59.5) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 122.25 66.45) (end 123.339998 66.45) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 125.9 63.889998) (end 125.9 60.236812) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 123.339998 66.45) (end 125.9 63.889998) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 119.785001 94.414997) (end 115.7605 98.439498) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 117.645024 114.779997) (end 112.9 119.525021) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.05 123.255) (end 110.459998 122.664998) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 117.5 88.815) (end 119.785001 91.100001) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 117.175001 107.424) (end 119.785001 110.034) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 119.785001 114.779997) (end 117.645024 114.779997) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 117.175001 105.4746) (end 117.175001 107.424) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 111.574979 119.525021) (end 112.9 119.525021) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 119.785001 91.100001) (end 119.785001 94.414997) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 115.7605 104.060099) (end 117.175001 105.4746) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 110.459998 120.640002) (end 111.574979 119.525021) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 119.785001 110.034) (end 119.785001 114.779997) (width 0.25) (layer F.Cu) (net 59)) + (segment (start 110.459998 122.664998) (end 110.459998 120.640002) (width 0.25) (layer B.Cu) (net 59)) + (segment (start 115.7605 98.439498) (end 115.7605 104.060099) (width 0.25) (layer F.Cu) (net 59)) + (via (at 112.9 119.525021) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 59)) + (segment (start 117.5 87.5) (end 117.5 88.815) (width 0.25) (layer F.Cu) (net 59)) + (via (at 154.5 53.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (segment (start 154.5 53.79) (end 151.5 53.79) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 151.5 53.79) (end 149.25 56.04) (width 0.25) (layer B.Cu) (net 60)) + (via (at 149.25 55.94) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (via (at 146.5 57.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (via (at 116.6 59.7) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 60)) + (segment (start 118.3 58.625) (end 117.675 58.625) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 117.675 58.625) (end 116.6 59.7) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 147.89 57.3) (end 149.25 55.94) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 146.5 57.3) (end 147.89 57.3) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 154.94 54.6735) (end 156.2915 54.6735) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 154.5 53.79) (end 154.5 54.2335) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 156.2915 54.6735) (end 156.3 54.665) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 154.5 54.2335) (end 154.94 54.6735) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 156.3 52.915) (end 154.984 52.915) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 154.5 53.399) (end 154.5 53.79) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 154.984 52.915) (end 154.5 53.399) (width 0.25) (layer F.Cu) (net 60)) + (segment (start 118.25 60.325) (end 118.3 60.375) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 116.967 60.325) (end 118.25 60.325) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 116.6 59.7) (end 116.6 59.958) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 116.6 59.958) (end 116.967 60.325) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 118.864998 60.375) (end 118.3 60.375) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 126 57) (end 125.4 57.6) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 126 56) (end 126 57) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 131.5 54) (end 128 54) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 121.639998 57.6) (end 118.864998 60.375) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 134.8 57.3) (end 131.5 54) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 128 54) (end 126 56) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 125.4 57.6) (end 121.639998 57.6) (width 0.25) (layer B.Cu) (net 60)) + (segment (start 146.5 57.3) (end 134.8 57.3) (width 0.25) (layer B.Cu) (net 60)) + (via (at 159 53.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (via (at 165.750003 56.789997) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 160.7 54.665) (end 162.575 54.665) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 162.575 54.665) (end 162.65 54.59) (width 0.25) (layer F.Cu) (net 61)) + (via (at 162.65 54.59) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 199.7 60.375) (end 199.025 60.375) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 199.7 62.125) (end 199.225 62.125) (width 0.25) (layer F.Cu) (net 61)) + (via (at 201.4 61.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 201.4 60.7475) (end 201.4 61.25) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 199.7 60.375) (end 201.0275 60.375) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 201.0275 60.375) (end 201.4 60.7475) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 199.7 62.125) (end 198.015 62.125) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 168.421606 59.4616) (end 165.750003 56.789997) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 174.436814 63.65) (end 170.248414 59.4616) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 170.248414 59.4616) (end 168.421606 59.4616) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 189.336812 63.65) (end 174.436814 63.65) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 163.550006 54.59) (end 162.65 54.59) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 165.750003 56.789997) (end 163.550006 54.59) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 160.6915 54.6735) (end 160.7 54.665) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159.4485 54.6735) (end 160.6915 54.6735) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159 53.79) (end 159 54.225) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159 54.225) (end 159.4485 54.6735) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 159 53.344) (end 159 53.79) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 160.7 52.915) (end 159.429 52.915) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 159.429 52.915) (end 159 53.344) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 200.892 62.125) (end 199.7 62.125) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 201.4 61.25) (end 201.4 61.617) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 201.4 61.617) (end 200.892 62.125) (width 0.25) (layer F.Cu) (net 61)) + (via (at 189.336812 63.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 189.3086 63.65) (end 189.336812 63.65) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 189.336812 63.65) (end 189.334 63.65) (width 0.25) (layer B.Cu) (net 61)) + (via (at 191.475 63.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 61)) + (segment (start 189.359 63.625) (end 191.475 63.625) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 189.334 63.65) (end 189.359 63.625) (width 0.25) (layer B.Cu) (net 61)) + (segment (start 192.293822 61.273992) (end 197.163992 61.273992) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 197.163992 61.273992) (end 198.015 62.125) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 191.475 62.092814) (end 192.293822 61.273992) (width 0.25) (layer F.Cu) (net 61)) + (segment (start 191.475 63.625) (end 191.475 62.092814) (width 0.25) (layer F.Cu) (net 61)) + (via (at 102.74 125.6775) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 151.2836 119.1376) (end 151.8154 119.1376) (width 0.25) (layer F.Cu) (net 62)) + (via (at 152.8174 118.1356) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 151.8154 119.1376) (end 152.8174 118.1356) (width 0.25) (layer F.Cu) (net 62)) + (via (at 148.347 122.121502) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 141.875001 124.840001) (end 141.875001 123.870999) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 143.624498 122.121502) (end 148.347 122.121502) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 140.214999 130.026801) (end 140.214999 126.500003) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 149.896896 119.1376) (end 148.347 120.687496) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 140.214999 126.500003) (end 141.875001 124.840001) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 151.2836 119.1376) (end 149.896896 119.1376) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 141.875001 123.870999) (end 143.624498 122.121502) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 148.347 120.687496) (end 148.347 122.121502) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 152.5031 117.3876) (end 151.2836 117.3876) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 152.8174 118.1356) (end 152.8174 117.7019) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 152.8174 117.7019) (end 152.5031 117.3876) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 140.214999 130.026801) (end 137.7418 132.5) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 137.7418 132.5) (end 131.024079 132.5) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 131.024079 132.5) (end 126.9 132.5) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 122.990613 136.409387) (end 111.690613 136.409387) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 126.9 132.5) (end 122.990613 136.409387) (width 0.25) (layer B.Cu) (net 62)) + (via (at 108.3 132) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 111.690613 136.409387) (end 108.3 133.018774) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 108.3 133.018774) (end 108.3 132) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 104.945 123.255) (end 106.65 123.255) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 102.74 125.6775) (end 102.74 125.46) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 102.74 125.46) (end 104.945 123.255) (width 0.25) (layer F.Cu) (net 62)) + (via (at 106.06801 126.351315) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 62)) + (segment (start 106.06801 129.76801) (end 106.06801 126.351315) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 108.3 132) (end 106.06801 129.76801) (width 0.25) (layer F.Cu) (net 62)) + (segment (start 102.74 125.74) (end 102.74 125.6775) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 103.4 126.4) (end 102.74 125.74) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 105.255 126.4) (end 103.4 126.4) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 106.06801 125.58699) (end 106.65 125.005) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 106.65 125.005) (end 105.6675 125.9875) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 105.704195 125.9875) (end 105.6675 125.9875) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 105.6675 125.9875) (end 105.255 126.4) (width 0.25) (layer B.Cu) (net 62)) + (segment (start 106.06801 126.351315) (end 105.704195 125.9875) (width 0.25) (layer B.Cu) (net 62)) + (via (at 188.822468 120.130068) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 63)) + (segment (start 187.25 121.195) (end 187.757536 121.195) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 187.757536 121.195) (end 188.822468 120.130068) (width 0.25) (layer F.Cu) (net 63)) + (via (at 145.2228 118.2118) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 63)) + (segment (start 146.8836 119.1376) (end 146.1486 119.1376) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 146.1486 119.1376) (end 145.2228 118.2118) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 145.2228 118.2118) (end 145.2228 117.653) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 145.4882 117.3876) (end 146.8836 117.3876) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 145.2228 117.653) (end 145.4882 117.3876) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 188.5315 119.4435) (end 187.2515 119.4435) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 187.2515 119.4435) (end 187.25 119.445) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 188.822468 120.130068) (end 188.822468 119.734468) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 188.822468 119.734468) (end 188.5315 119.4435) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 188.822468 120.130068) (end 186.427537 122.524999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 186.427537 122.524999) (end 179.840001 122.524999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 173.5692 121.3868) (end 171.097399 118.914999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 146.8836 119.1376) (end 148.9191 119.1376) (width 0.25) (layer B.Cu) (net 63)) + (via (at 149.7965 120.015) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 63)) + (segment (start 178.701802 121.3868) (end 173.5692 121.3868) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 148.9191 119.1376) (end 149.7965 120.015) (width 0.25) (layer B.Cu) (net 63)) + (segment (start 153.5034 120.015) (end 149.7965 120.015) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 171.097399 118.914999) (end 154.603401 118.914999) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 179.840001 122.524999) (end 178.701802 121.3868) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 154.603401 118.914999) (end 153.5034 120.015) (width 0.25) (layer F.Cu) (net 63)) + (segment (start 195.3 60.375) (end 195.19999 60.27499) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 195.3 62.125) (end 195.875001 62.125) (width 0.25) (layer B.Cu) (net 64)) + (via (at 190.95 61.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 195.3 60.375) (end 191.975 60.375) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 191.975 60.375) (end 190.95 61.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 190.95 64.427002) (end 190.95 61.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.25 67.722998) (end 187.997999 66.974999) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 188.402003 66.974999) (end 190.95 64.427002) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.997999 66.974999) (end 188.402003 66.974999) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 192.034 62.484) (end 190.95 61.4) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 195.3 62.125) (end 194.941 62.484) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 194.941 62.484) (end 192.034 62.484) (width 0.25) (layer B.Cu) (net 64)) + (via (at 111.403027 84.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 111.412999 84.240028) (end 111.403027 84.25) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 112.5 80.5) (end 111.412999 81.587001) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 111.403027 84.25) (end 108.55 84.25) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 181.5 94.65) (end 172.75 94.65) (width 0.25) (layer B.Cu) (net 64)) + (via (at 170 94.675) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 172.75 94.65) (end 170.025 94.65) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 170.025 94.65) (end 170 94.675) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 170 94.675) (end 168.975 93.65) (width 0.25) (layer F.Cu) (net 64)) + (via (at 168.75 93.625) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 168.975 93.65) (end 168.775 93.65) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 168.775 93.65) (end 168.75 93.625) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 168.725 93.65) (end 168.75 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 103.67005 86.50495) (end 104.704243 86.50495) (width 0.25) (layer B.Cu) (net 64)) + (via (at 104.704243 86.50495) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 103.55 87.375) (end 103.55 86.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 103.55 86.625) (end 103.67005 86.50495) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 108.55 84.25) (end 108.5 84.25) (width 0.25) (layer B.Cu) (net 64) (tstamp 5FDB7154)) + (via (at 108.55 84.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 103.55 85.625) (end 103.55 84.8375) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 107.65 83.4) (end 108.5 84.25) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 104.9875 83.4) (end 107.65 83.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 103.55 84.8375) (end 104.9875 83.4) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 104.704243 86.304243) (end 104.704243 86.50495) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 103.55 85.625) (end 104.025 85.625) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 104.025 85.625) (end 104.704243 86.304243) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 111.412999 81.587001) (end 111.412999 82.389001) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 111.412999 82.389001) (end 111.412999 84.240028) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 112.522 80.522) (end 112.5 80.5) (width 0.25) (layer F.Cu) (net 64)) + (via (at 112.5 80.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 112.522 82.30362) (end 112.522 80.522) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 185.474999 98.809421) (end 185.4454 98.83902) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.25 86.65) (end 185.474999 88.425001) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 187.25 67.622998) (end 187.25 86.65) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 183.213401 96.363401) (end 185.474999 96.363401) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 181.5 94.65) (end 183.213401 96.363401) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 185.474999 96.363401) (end 185.474999 98.809421) (width 0.25) (layer F.Cu) (net 64)) + (via (at 185.474999 96.363401) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 64)) + (segment (start 185.474999 88.425001) (end 185.474999 96.363401) (width 0.25) (layer F.Cu) (net 64)) + (segment (start 168.467158 93.625) (end 168.75 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 166.285 93.625) (end 168.467158 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 164.45 91.79) (end 166.285 93.625) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 129.95 90.35) (end 133.20001 93.60001) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 133.20001 93.60001) (end 148.70358 93.60001) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 153.42789 92.36791) (end 154.0058 91.79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 153.43978 92.3798) (end 153.42789 92.36791) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 112.5 80.5) (end 113.512 80.5) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 129.95 85.286) (end 129.95 90.35) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 148.70358 93.60001) (end 149.92379 92.3798) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 154.0058 91.79) (end 164.45 91.79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 123.664 79) (end 129.95 85.286) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 115.012 79) (end 123.664 79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 113.512 80.5) (end 115.012 79) (width 0.25) (layer B.Cu) (net 64)) + (segment (start 149.92379 92.3798) (end 153.43978 92.3798) (width 0.25) (layer B.Cu) (net 64)) + (via (at 143.240373 41.790373) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 65)) + (segment (start 117.8 45.375) (end 116.4 43.975) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 116.4 43.975) (end 116.4 43.45) (width 0.25) (layer F.Cu) (net 65)) + (via (at 116.4 43.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 65)) + (segment (start 118.1 45.375) (end 117.8 45.375) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 142.255746 42.775) (end 143.240373 41.790373) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 141.9 42.775) (end 142.255746 42.775) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 141.9 44.55) (end 141.9 42.775) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 141.45 45) (end 141.9 44.55) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 134.717 45) (end 141.45 45) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 118.2 41.65) (end 131.367 41.65) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 116.4 43.45) (end 118.2 41.65) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 131.367 41.65) (end 134.717 45) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 143.240373 41.360973) (end 143.240373 41.790373) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 141.9 41.025) (end 142.9044 41.025) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 142.9044 41.025) (end 143.240373 41.360973) (width 0.25) (layer F.Cu) (net 65)) + (segment (start 118.1 43.625) (end 117.91 43.815) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 116.765 43.815) (end 116.4 43.45) (width 0.25) (layer B.Cu) (net 65)) + (segment (start 117.91 43.815) (end 116.765 43.815) (width 0.25) (layer B.Cu) (net 65)) + (via (at 116.75 63.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 66)) + (segment (start 118.1 62.725) (end 117.775 62.725) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 117.775 62.725) (end 116.75 63.75) (width 0.25) (layer B.Cu) (net 66)) + (via (at 125.45 44.300002) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 66)) + (segment (start 124.774998 43.625) (end 125.45 44.300002) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 122.9 45.375) (end 124.375002 45.375) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 124.375002 45.375) (end 125.45 44.300002) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 122.9 43.625) (end 124.774998 43.625) (width 0.25) (layer F.Cu) (net 66)) + (via (at 116.2 65.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 66)) + (segment (start 116.6905 64.475) (end 118.1 64.475) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.2 65.45) (end 116.2 64.9655) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.2 64.9655) (end 116.6905 64.475) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.75 64.4155) (end 116.6905 64.475) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 116.75 63.75) (end 116.75 64.4155) (width 0.25) (layer F.Cu) (net 66)) + (segment (start 123.1879 45.375) (end 122.9 45.375) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 115.600001 57.799999) (end 118.450001 57.799999) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 118.450001 57.799999) (end 120 56.25) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 116.2 65.45) (end 115.22499 64.47499) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.85 46.0371) (end 123.1879 45.375) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 115.22499 58.17501) (end 115.600001 57.799999) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.824999 49.435999) (end 123.85 49.410998) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 115.22499 64.47499) (end 115.22499 58.17501) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.824999 50.190003) (end 123.824999 49.435999) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 123.85 49.410998) (end 123.85 46.0371) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 120 56.25) (end 120 54.015002) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 120 54.015002) (end 123.824999 50.190003) (width 0.25) (layer B.Cu) (net 66)) + (segment (start 137.1 41.025) (end 136.425 41.025) (width 0.25) (layer B.Cu) (net 67)) + (via (at 135.55 41.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 67)) + (segment (start 136.425 41.025) (end 135.55 41.9) (width 0.25) (layer B.Cu) (net 67)) + (via (at 143.35 60.949994) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 67)) + (segment (start 142.424994 61.875) (end 143.35 60.949994) (width 0.25) (layer B.Cu) (net 67)) + (segment (start 141.9 61.875) (end 142.424994 61.875) (width 0.25) (layer B.Cu) (net 67)) + (segment (start 143.35 60.4825) (end 143.35 60.949994) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 142.9925 60.125) (end 143.35 60.4825) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 141.9 60.125) (end 142.9925 60.125) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 138.785001 50.200003) (end 138.785001 55.085001) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 136.425 42.775) (end 137.1 42.775) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 135.55 41.9) (end 136.425 42.775) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 137.1 42.775) (end 136.524998 43.350002) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 138.785001 55.085001) (end 141.9 58.2) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 136.524998 43.350002) (end 136.524998 47.94) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 141.9 58.2) (end 141.9 60.125) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 136.524998 47.94) (end 138.785001 50.200003) (width 0.25) (layer F.Cu) (net 67)) + (segment (start 180 41.125) (end 179.775 41.125) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 180 42.875) (end 179.725 42.875) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 181.05 41.125) (end 182.75 42.825) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 180 41.125) (end 181.05 41.125) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 182.75 42.963186) (end 181.113186 44.6) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 182.75 42.825) (end 182.75 42.963186) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 181.113186 44.6) (end 180.25 44.6) (width 0.25) (layer F.Cu) (net 68)) + (via (at 180.25 44.599999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 68)) + (segment (start 180.25 44.6) (end 180.25 44.599999) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 180.25 43.125) (end 180 42.875) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 180.25 44.599999) (end 180.25 43.125) (width 0.25) (layer B.Cu) (net 68)) + (via (at 154.71924 39.40001) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 68)) + (segment (start 154.71924 39.84774) (end 154.71924 39.40001) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.2 40.375) (end 155.2465 40.375) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 155.2465 40.375) (end 154.71924 39.84774) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 154.71924 39.01926) (end 154.71924 39.40001) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 156.2 38.625) (end 155.1135 38.625) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 155.1135 38.625) (end 154.71924 39.01926) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 162.415999 41.969199) (end 170.026722 41.969199) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 162.210209 42.174989) (end 162.415999 41.969199) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.4 42.174989) (end 162.210209 42.174989) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.2 41.974989) (end 156.4 42.174989) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 156.2 40.375) (end 156.2 41.974989) (width 0.25) (layer F.Cu) (net 68)) + (via (at 174.6 44.599999) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 68)) + (segment (start 174.37124 44.371239) (end 174.6 44.599999) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 172.428761 44.371239) (end 174.37124 44.371239) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 170.026722 41.969199) (end 172.428761 44.371239) (width 0.25) (layer F.Cu) (net 68)) + (segment (start 174.6 44.599999) (end 175.000001 45) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 179.849999 45) (end 180.25 44.599999) (width 0.25) (layer B.Cu) (net 68)) + (segment (start 175.000001 45) (end 179.849999 45) (width 0.25) (layer B.Cu) (net 68)) + (via (at 154.75 58.79) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 69)) + (segment (start 156.2 57.715) (end 155.825 57.715) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 155.825 57.715) (end 154.75 58.79) (width 0.25) (layer B.Cu) (net 69)) + (via (at 162.500016 39.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 69)) + (segment (start 162.5 39.54) (end 162.500016 39.54) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 162 40.04) (end 162.5 39.54) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161 40.375) (end 161.335 40.04) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.335 40.04) (end 162 40.04) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.9 40.9325) (end 161.3425 40.375) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.9 45.215002) (end 161.9 40.9325) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 158.474999 48.640003) (end 161.9 45.215002) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161.3425 40.375) (end 161 40.375) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 156.2 56.165) (end 156.575 55.79) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 156.2 57.715) (end 156.2 56.165) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 157.260002 55.79) (end 158.474999 54.575003) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 156.575 55.79) (end 157.260002 55.79) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 158.474999 54.575003) (end 158.474999 48.640003) (width 0.25) (layer B.Cu) (net 69)) + (segment (start 161 38.625) (end 162.0055 38.625) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 162.500016 39.119516) (end 162.500016 39.54) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 162.0055 38.625) (end 162.500016 39.119516) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 156.175 59.44) (end 156.2 59.465) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 155.1345 59.44) (end 156.175 59.44) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 154.75 58.79) (end 154.75 59.0555) (width 0.25) (layer F.Cu) (net 69)) + (segment (start 154.75 59.0555) (end 155.1345 59.44) (width 0.25) (layer F.Cu) (net 69)) + (via (at 173 42.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 70)) + (segment (start 175.2 42.875) (end 173.725 42.875) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 173.725 42.875) (end 173 42.15) (width 0.25) (layer F.Cu) (net 70)) + (via (at 176.8005 50.3495) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 70)) + (segment (start 173.525 41.125) (end 175.2 41.125) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173 42.15) (end 173 41.65) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173 41.65) (end 173.525 41.125) (width 0.25) (layer B.Cu) (net 70)) + (via (at 181.549998 61.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 70)) + (segment (start 181.05 61.75) (end 181.549998 61.250002) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 181.549998 61.250002) (end 181.549998 61.1) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 180 61.875) (end 180.125 61.75) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 180.125 61.75) (end 181.05 61.75) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 180 58) (end 180 60.125) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 176.8005 50.3495) (end 178.314999 51.863999) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 178.314999 56.314999) (end 180 58) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 178.314999 51.863999) (end 178.314999 56.314999) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 181.242 61.1) (end 181.549998 61.1) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 180 60.125) (end 180.267 60.125) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 180.267 60.125) (end 181.242 61.1) (width 0.25) (layer F.Cu) (net 70)) + (segment (start 175.224999 48.773998) (end 176.8005 50.3495) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 175.224999 46.024999) (end 175.224999 48.773998) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173.8 44.6) (end 175.224999 46.024999) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173 42.15) (end 173.8 42.95) (width 0.25) (layer B.Cu) (net 70)) + (segment (start 173.8 42.95) (end 173.8 44.6) (width 0.25) (layer B.Cu) (net 70)) + (via (at 192.8 46.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 193.054 46.75) (end 192.8 46.75) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 194.3 47.775) (end 194.079 47.775) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 194.079 47.775) (end 193.054 46.75) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.659 46.891) (end 192.659 47.909) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.8 46.75) (end 192.659 46.891) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.659 47.909) (end 194.3 49.55) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 194.3 49.55) (end 204.63641 49.55) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 204.63641 49.55) (end 206.91701 47.2694) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 192.8 46.341) (end 192.8 46.75) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 194.3 46.025) (end 193.116 46.025) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 193.116 46.025) (end 192.8 46.341) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 218.1 46.025) (end 218.62499 46.025) (width 0.25) (layer F.Cu) (net 71)) + (via (at 219.4 47) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 218.2 46.025) (end 218.425 46.025) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 218.425 46.025) (end 219.4 47) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 206.922609 47.274999) (end 206.91701 47.2694) (width 0.25) (layer F.Cu) (net 71)) + (via (at 218.4 44.4) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 218.4 45.825) (end 218.2 46.025) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 218.4 44.4) (end 218.4 45.825) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 218.425 47.775) (end 218.2 47.775) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 219.4 47) (end 219.2 47) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 219.2 47) (end 218.425 47.775) (width 0.25) (layer B.Cu) (net 71)) + (via (at 209.8 46.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 71)) + (segment (start 207.515708 46.6819) (end 206.922609 47.274999) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 209.3181 46.6819) (end 207.515708 46.6819) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 209.3181 46.6819) (end 209.8 46.2) (width 0.25) (layer F.Cu) (net 71)) + (segment (start 211.799999 44.200001) (end 211.4898 44.5102) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 218.200001 44.200001) (end 211.799999 44.200001) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 218.4 44.4) (end 218.200001 44.200001) (width 0.25) (layer B.Cu) (net 71)) + (segment (start 209.8 46.2) (end 211.4898 44.5102) (width 0.25) (layer B.Cu) (net 71)) + (via (at 200.75 47) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 72)) + (segment (start 194.3 64.925) (end 194.075 64.925) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 193 66.35) (end 193.25 66.6) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 193 66) (end 193 66.35) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 193.25 66.6) (end 194.225 66.6) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 194.225 66.6) (end 194.3 66.675) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 194.075 64.925) (end 193 66) (width 0.25) (layer B.Cu) (net 72)) + (via (at 193 66) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 72)) + (segment (start 200.75 46.445) (end 200.75 47) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 199.1 46.025) (end 200.33 46.025) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 200.33 46.025) (end 200.75 46.445) (width 0.25) (layer F.Cu) (net 72)) + (segment (start 199.25 47.625) (end 199.1 47.775) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200.279 47.625) (end 199.25 47.625) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200.75 47) (end 200.75 47.154) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200.75 47.154) (end 200.279 47.625) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 197.275001 62.503499) (end 196.67849 63.10001) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200 48.362) (end 200 52.748998) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 197.275001 55.473997) (end 197.275001 62.503499) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 199.1 47.775) (end 199.413 47.775) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 199.413 47.775) (end 200 48.362) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 200 52.748998) (end 197.275001 55.473997) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 194.834291 63.10001) (end 196.67849 63.10001) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 194.3 63.634301) (end 194.834291 63.10001) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 194.3 64.925) (end 194.3 63.634301) (width 0.25) (layer B.Cu) (net 72)) + (segment (start 213.3 46.025) (end 212.974996 46.025) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 213.3 47.775) (end 212.775004 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.3 47.775) (end 213.3 47.8994) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.3 46.025) (end 212.9788 46.025) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 213.272 47.803) (end 213.3 47.775) (width 0.25) (layer F.Cu) (net 73)) + (via (at 219.5195 65.8495) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (segment (start 219.5195 66.2305) (end 219.5195 65.8495) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 218.1 66.675) (end 219.075 66.675) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 219.075 66.675) (end 219.5195 66.2305) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 219.5195 65.2145) (end 219.5195 65.8495) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 218.1 64.925) (end 219.23 64.925) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 219.23 64.925) (end 219.5195 65.2145) (width 0.25) (layer F.Cu) (net 73)) + (via (at 212 47) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (segment (start 213.4 46.025) (end 212.975 46.025) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 212.975 46.025) (end 212 47) (width 0.25) (layer B.Cu) (net 73)) + (via (at 212.8 50.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (via (at 212.8 49) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 73)) + (segment (start 212.8 50.8) (end 212.8 49) (width 0.25) (layer B.Cu) (net 73)) + (segment (start 212.8 49) (end 213.2 48.6) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.2 47.975) (end 213.4 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 213.2 48.6) (end 213.2 47.975) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.975 47.775) (end 213.4 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212 47) (end 212.2 47) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.2 47) (end 212.975 47.775) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 216.0888 57.5962) (end 216.0888 61.2888) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 214.659999 56.167399) (end 216.0888 57.5962) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 218.1 63.3) (end 218.1 64.925) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 216.0888 61.2888) (end 218.1 63.3) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 214.659999 54.775001) (end 214.659999 56.167399) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.8 52.915002) (end 214.659999 54.775001) (width 0.25) (layer F.Cu) (net 73)) + (segment (start 212.8 50.8) (end 212.8 52.915002) (width 0.25) (layer F.Cu) (net 73)) + (via (at 116.275021 82.255755) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 116.275021 82.255755) (end 116.275021 81.174979) (width 0.25) (layer B.Cu) (net 74)) + (via (at 120.800002 79.525) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 116.275021 81.174979) (end 117.925 79.525) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 117.925 79.525) (end 120.800002 79.525) (width 0.25) (layer B.Cu) (net 74)) + (via (at 124.6 63.45) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 122.9 64.475) (end 123.575 64.475) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 123.575 64.475) (end 124.6 63.45) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 124.6 63.45) (end 123.95 62.8) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 122.975 62.8) (end 122.9 62.725) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 123.95 62.8) (end 122.975 62.8) (width 0.25) (layer F.Cu) (net 74)) + (via (at 122.923621 65.881628) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 74)) + (segment (start 122.9 65.858007) (end 122.923621 65.881628) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 122.9 64.475) (end 122.9 65.858007) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 122.875001 70.373997) (end 122.875001 65.930248) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 122.875001 65.930248) (end 122.923621 65.881628) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 120.800002 72.448996) (end 122.875001 70.373997) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 120.85 79.5) (end 120.800002 79.450002) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 120.800002 79.450002) (end 120.800002 72.448996) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 116.298276 82.2325) (end 116.275021 82.255755) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 118.1 81.725) (end 117.5925 82.2325) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 117.5925 82.2325) (end 116.298276 82.2325) (width 0.25) (layer B.Cu) (net 74)) + (segment (start 118.1 83.475) (end 117.8285 83.475) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 116.609255 82.255755) (end 116.275021 82.255755) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 117.8285 83.475) (end 116.609255 82.255755) (width 0.25) (layer F.Cu) (net 74)) + (segment (start 141.9 80.875) (end 142.675 80.875) (width 0.25) (layer B.Cu) (net 75)) + (segment (start 142.675 80.875) (end 143.65 79.9) (width 0.25) (layer B.Cu) (net 75)) + (via (at 143.65 79.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 75)) + (via (at 135.65 60.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 75)) + (segment (start 137.1 60.125) (end 136.475 60.125) (width 0.25) (layer B.Cu) (net 75)) + (segment (start 136.475 60.125) (end 135.65 60.95) (width 0.25) (layer B.Cu) (net 75)) + (segment (start 143.65 79.642) (end 143.65 79.9) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 141.9 76.65) (end 141.9 79.125) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 140.214999 74.964999) (end 141.9 76.65) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 136.575 61.875) (end 137.1 61.875) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 143.133 79.125) (end 143.65 79.642) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 135.65 60.95) (end 136.575 61.875) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 137.1 61.875) (end 137.1 67.615002) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 141.9 79.125) (end 143.133 79.125) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 137.1 67.615002) (end 140.214999 70.730001) (width 0.25) (layer F.Cu) (net 75)) + (segment (start 140.214999 70.730001) (end 140.214999 74.964999) (width 0.25) (layer F.Cu) (net 75)) + (via (at 153.6 78.04) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 76)) + (segment (start 154.125 78.565) (end 153.6 78.04) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 156.2 78.565) (end 154.125 78.565) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 153.6 77.626812) (end 153.6 78.04) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 156.2 76.815) (end 154.411812 76.815) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 154.411812 76.815) (end 153.6 77.626812) (width 0.25) (layer B.Cu) (net 76)) + (via (at 162.3 58.74) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 76)) + (segment (start 161.275 57.715) (end 161 57.715) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 162.3 58.74) (end 161.275 57.715) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 163.55 60.14) (end 161.533999 62.156001) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 161.533999 64.756001) (end 159.314999 66.975001) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 161.533999 62.156001) (end 161.533999 64.756001) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 153.6 77.298312) (end 153.6 78.04) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 163.55 59.14) (end 163.55 60.14) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 162.3 58.74) (end 163.15 58.74) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 159.314999 71.583313) (end 153.6 77.298312) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 159.314999 66.975001) (end 159.314999 71.583313) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 163.15 58.74) (end 163.55 59.14) (width 0.25) (layer F.Cu) (net 76)) + (segment (start 162.3 59.1372) (end 162.3 58.74) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 161 59.465) (end 161.9722 59.465) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 161.9722 59.465) (end 162.3 59.1372) (width 0.25) (layer B.Cu) (net 76)) + (segment (start 175.2 61.875) (end 175.525 61.875) (width 0.25) (layer F.Cu) (net 77)) + (via (at 175 64.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 180 80.975) (end 180.925 80.975) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 180.925 80.975) (end 181.6 80.3) (width 0.25) (layer B.Cu) (net 77)) + (via (at 181.6 80.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 178.314999 70.730001) (end 175 67.415002) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 178.314999 75.564999) (end 178.314999 70.730001) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180 79.225) (end 180 77.25) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 175 67.415002) (end 175 64.65) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180 77.25) (end 178.314999 75.564999) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 175.2 60.125) (end 174.625 60.125) (width 0.25) (layer B.Cu) (net 77)) + (via (at 173.7 61.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 174.625 60.125) (end 173.7 61.05) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 173.7 61.05) (end 173.7 61.1) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 175.2 61.875) (end 175.2 63) (width 0.25) (layer F.Cu) (net 77)) + (via (at 175.15 63.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 77)) + (segment (start 175.2 63) (end 175.15 63.05) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 175.15 64.5) (end 175 64.65) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 175.15 63.05) (end 175.15 64.5) (width 0.25) (layer B.Cu) (net 77)) + (segment (start 174.905 61.875) (end 175.2 61.875) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 173.7 61.1) (end 174.13 61.1) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 174.13 61.1) (end 174.905 61.875) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 181.392 80.3) (end 181.6 80.3) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180 79.225) (end 180.317 79.225) (width 0.25) (layer F.Cu) (net 77)) + (segment (start 180.317 79.225) (end 181.392 80.3) (width 0.25) (layer F.Cu) (net 77)) + (via (at 193.6 79.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 78)) + (segment (start 192.525 85.875) (end 191.75 85.1) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 191.75 81.65) (end 191.75 85.1) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 193.6 79.8) (end 191.75 81.65) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 194.3 85.875) (end 192.525 85.875) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 194.3 84.125) (end 192.725 84.125) (width 0.25) (layer B.Cu) (net 78)) + (via (at 191.75 85.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 78)) + (segment (start 192.725 84.125) (end 191.75 85.1) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.550014 64.925) (end 200.650004 66.02499) (width 0.25) (layer F.Cu) (net 78)) + (segment (start 199.1 64.925) (end 199.550014 64.925) (width 0.25) (layer F.Cu) (net 78)) + (via (at 200.650004 66.02499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 78)) + (segment (start 195.985001 77.414999) (end 195.985001 75.663997) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 193.6 79.8) (end 195.985001 77.414999) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.1 67.7185) (end 199.1 66.675) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.9 68.5185) (end 199.1 67.7185) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.9 71.748998) (end 199.9 68.5185) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 195.985001 75.663997) (end 199.9 71.748998) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 200.650004 66.240496) (end 200.650004 66.02499) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 199.1 66.675) (end 200.2155 66.675) (width 0.25) (layer B.Cu) (net 78)) + (segment (start 200.2155 66.675) (end 200.650004 66.240496) (width 0.25) (layer B.Cu) (net 78)) + (via (at 219.75 84.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 79)) + (segment (start 213.3 66.675) (end 212.675 66.675) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 218.1 84.125) (end 218.1 80.07499) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 218.1 80.07499) (end 216 77.97499) (width 0.25) (layer F.Cu) (net 79)) + (via (at 216 77.97499) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 79)) + (via (at 210.951402 66.95) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 79)) + (segment (start 211.226402 66.675) (end 210.951402 66.95) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 213.3 64.925) (end 211.725 64.925) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 210.951402 65.698598) (end 210.951402 66.95) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 213 72.248999) (end 213 68.998598) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 213 68.998598) (end 210.951402 66.95) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 216 75.248999) (end 213 72.248999) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 216 77.97499) (end 216 75.248999) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 211.725 64.925) (end 210.951402 65.698598) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 213.3 66.675) (end 211.226402 66.675) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.202 84.201) (end 218.176 84.201) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 218.176 84.201) (end 218.1 84.125) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.75 84.75) (end 219.75 84.749) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.75 84.749) (end 219.202 84.201) (width 0.25) (layer F.Cu) (net 79)) + (segment (start 219.75 85.304) (end 219.75 84.75) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 218.1 85.875) (end 219.179 85.875) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 219.179 85.875) (end 219.75 85.304) (width 0.25) (layer B.Cu) (net 79)) + (segment (start 123.125 81.5) (end 122.9 81.725) (width 0.25) (layer F.Cu) (net 80)) + (via (at 116.975317 101.458646) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 80)) + (segment (start 117.366354 101.458646) (end 116.975317 101.458646) (width 0.25) (layer B.Cu) (net 80)) + (segment (start 118.1 100.725) (end 117.366354 101.458646) (width 0.25) (layer B.Cu) (net 80)) + (segment (start 125.425 83.475) (end 125.45 83.5) (width 0.25) (layer B.Cu) (net 80)) + (segment (start 122.9 83.475) (end 125.425 83.475) (width 0.25) (layer B.Cu) (net 80)) + (via (at 125.45 83.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 80)) + (segment (start 125.45 82.865188) (end 125.45 83.5) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 124.309812 81.725) (end 125.45 82.865188) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 122.9 81.725) (end 124.309812 81.725) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.210511 100.69384) (end 116.210511 99.326301) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.975317 101.458646) (end 116.210511 100.69384) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 123.824999 86.588189) (end 125.45 84.963188) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.210511 99.326301) (end 121.214999 94.321813) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 121.214999 90.900003) (end 123.824999 88.290003) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 125.45 84.963188) (end 125.45 83.5) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 121.214999 94.321813) (end 121.214999 90.900003) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 123.824999 88.290003) (end 123.824999 86.588189) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 116.975317 101.608317) (end 116.975317 101.458646) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 118.1 102.475) (end 117.842 102.475) (width 0.25) (layer F.Cu) (net 80)) + (segment (start 117.842 102.475) (end 116.975317 101.608317) (width 0.25) (layer F.Cu) (net 80)) + (via (at 143.6 99.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 81)) + (segment (start 137.1 79.125) (end 136.325 79.125) (width 0.25) (layer B.Cu) (net 81)) + (via (at 135.35 80.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 81)) + (segment (start 136.325 79.125) (end 135.35 80.1) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 141.9 99.975) (end 142.976 99.975) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 143.6 99.351) (end 143.6 99.05) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 142.976 99.975) (end 143.6 99.351) (width 0.25) (layer B.Cu) (net 81)) + (segment (start 142.9925 98.225) (end 143.6 98.8325) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 141.9 98.225) (end 142.9925 98.225) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 141.95 98.175) (end 141.9 98.225) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 141.95 96.55) (end 141.95 98.175) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 140.214999 94.814999) (end 141.95 96.55) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 136.125 80.875) (end 137.1 80.875) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 140.214999 89.863998) (end 140.214999 94.814999) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 143.6 98.8325) (end 143.6 99.05) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 135.35 80.1) (end 136.125 80.875) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 137.1 80.875) (end 137.1 86.748999) (width 0.25) (layer F.Cu) (net 81)) + (segment (start 137.1 86.748999) (end 140.214999 89.863998) (width 0.25) (layer F.Cu) (net 81)) + (via (at 154.75 96.54) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 156.2 97.565) (end 155.775 97.565) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 155.775 97.565) (end 154.75 96.54) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 158.75 86.688998) (end 158.75 90.04) (width 0.25) (layer B.Cu) (net 82)) + (via (at 158.75 90.04) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 161 78.565) (end 161 84.438998) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 161 84.438998) (end 158.75 86.688998) (width 0.25) (layer B.Cu) (net 82)) + (via (at 155.4 92.814979) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 158.75 90.04) (end 155.975021 92.814979) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 156.2 93.614979) (end 155.4 92.814979) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 155.975021 92.814979) (end 155.4 92.814979) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 156.2 95.815) (end 156.2 93.614979) (width 0.25) (layer B.Cu) (net 82)) + (via (at 162.169493 77.468245) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 82)) + (segment (start 161.986745 77.468245) (end 162.169493 77.468245) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 161 76.815) (end 161.3335 76.815) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 161.3335 76.815) (end 161.986745 77.468245) (width 0.25) (layer F.Cu) (net 82)) + (segment (start 155.702 96.0755) (end 155.9395 96.0755) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 154.75 96.54) (end 155.2375 96.54) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 155.9395 96.0755) (end 156.2 95.815) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 155.2375 96.54) (end 155.702 96.0755) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 161 78.565) (end 161.3253 78.565) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 162.169493 77.720807) (end 162.169493 77.468245) (width 0.25) (layer B.Cu) (net 82)) + (segment (start 161.3253 78.565) (end 162.169493 77.720807) (width 0.25) (layer B.Cu) (net 82)) + (via (at 181.25 98.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 83)) + (via (at 175.25 83.425) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 83)) + (segment (start 175.224999 83.450001) (end 175.25 83.425) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 180 96.5) (end 178.314999 94.814999) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 178.314999 89.964999) (end 175.224999 86.874999) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 180 98.325) (end 180 96.5) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 178.314999 94.814999) (end 178.314999 89.964999) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 175.224999 86.874999) (end 175.224999 83.450001) (width 0.25) (layer F.Cu) (net 83)) + (via (at 173.5 80.349998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 83)) + (segment (start 175.2 80.975) (end 174.125002 80.975) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 174.125002 80.975) (end 173.5 80.349998) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 175.25 81.025) (end 175.2 80.975) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 175.25 83.425) (end 175.25 81.025) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 180 100.075) (end 180.214 100.075) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 181.25 99.039) (end 181.25 98.9) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 180.214 100.075) (end 181.25 99.039) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 180.0365 98.3615) (end 180 98.325) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 181.0385 98.3615) (end 180.0365 98.3615) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 181.25 98.9) (end 181.25 98.573) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 181.25 98.573) (end 181.0385 98.3615) (width 0.25) (layer F.Cu) (net 83)) + (segment (start 173.5 79.738) (end 173.5 80.349998) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 175.2 79.225) (end 174.013 79.225) (width 0.25) (layer B.Cu) (net 83)) + (segment (start 174.013 79.225) (end 173.5 79.738) (width 0.25) (layer B.Cu) (net 83)) + (via (at 193.034627 103.965373) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 193.875 103.125) (end 193.034627 103.965373) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 194.3 103.125) (end 193.875 103.125) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.4 85.875) (end 200.6 84.675) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.1 84.125) (end 200.075 84.125) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 200.075 84.125) (end 200.6 84.65) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 200.6 84.675) (end 200.6 84.65) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.1 85.875) (end 199.4 85.875) (width 0.25) (layer B.Cu) (net 84)) + (via (at 200.6 84.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 194.3 103.125) (end 194.3 100.149998) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 194.3 100.149998) (end 196.4 98.049998) (width 0.25) (layer B.Cu) (net 84)) + (via (at 196.4 98.049998) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 193.034627 104.579127) (end 193.034627 103.965373) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 194.3 104.875) (end 194.275 104.85) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 193.3055 104.85) (end 193.034627 104.579127) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 194.275 104.85) (end 193.3055 104.85) (width 0.25) (layer F.Cu) (net 84)) + (via (at 199.771 87.349989) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 84)) + (segment (start 199.1 85.875) (end 199.1 86.678989) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 199.771 90.944002) (end 199.771 87.349989) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 199.1 86.678989) (end 199.771 87.349989) (width 0.25) (layer B.Cu) (net 84)) + (segment (start 196.4 98.049998) (end 196.399999 94.315003) (width 0.25) (layer F.Cu) (net 84)) + (segment (start 196.399999 94.315003) (end 199.771 90.944002) (width 0.25) (layer F.Cu) (net 84)) + (via (at 212 85) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 85)) + (segment (start 213.3 85.875) (end 212.875 85.875) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 212.875 85.875) (end 212 85) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 219.2 104.875) (end 219.425 104.65) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 218.15 103.125) (end 219.425 103.125) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 218.15 104.875) (end 219.2 104.875) (width 0.25) (layer B.Cu) (net 85)) + (via (at 219.425 103.125) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 85)) + (segment (start 219.425 104.65) (end 219.425 103.125) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 219.525 103.125) (end 218.15 103.125) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 213.3 91.615002) (end 216.414999 94.730001) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 219.85 102.8) (end 219.525 103.125) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 213.3 85.875) (end 213.3 91.615002) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 216.414999 94.730001) (end 216.414999 97.014999) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 219.85 100.45) (end 219.85 102.8) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 216.414999 97.014999) (end 219.85 100.45) (width 0.25) (layer F.Cu) (net 85)) + (segment (start 213.2875 84.1375) (end 213.3 84.125) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 212.9155 84.1375) (end 213.2875 84.1375) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 212 85) (end 212.053 85) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 212.053 85) (end 212.9155 84.1375) (width 0.25) (layer B.Cu) (net 85)) + (segment (start 123.475 102.475) (end 124.45 101.5) (width 0.25) (layer B.Cu) (net 86)) + (segment (start 122.9 102.475) (end 123.475 102.475) (width 0.25) (layer B.Cu) (net 86)) + (via (at 124.45 101.5) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 86)) + (segment (start 122.9 100.725) (end 123.966 100.725) (width 0.25) (layer F.Cu) (net 86)) + (segment (start 124.45 101.209) (end 124.45 101.5) (width 0.25) (layer F.Cu) (net 86)) + (segment (start 123.966 100.725) (end 124.45 101.209) (width 0.25) (layer F.Cu) (net 86)) + (via (at 135.70001 98.757169) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (via (at 125.2076 117.128) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (via (at 125.2584 118.415) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (segment (start 129.0044 105.1456) (end 129.0044 113.3312) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 134.693093 103.368407) (end 130.781593 103.368407) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 130.781593 103.368407) (end 129.0044 105.1456) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 135.70001 99.63201) (end 136.043 99.975) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 135.70001 98.757169) (end 135.70001 99.63201) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 136.043 99.975) (end 137.1 99.975) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 137.033 101.0285) (end 134.693093 103.368407) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 137.1 99.975) (end 137.033 100.042) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 137.033 100.042) (end 137.033 101.0285) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 135.70001 98.48799) (end 135.70001 98.757169) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 137.1 98.225) (end 135.963 98.225) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 135.963 98.225) (end 135.70001 98.48799) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 129.0044 113.3312) (end 125.2076 117.128) (width 0.25) (layer F.Cu) (net 87)) + (via (at 120 125.9) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (segment (start 125.2076 118.3642) (end 125.2584 118.415) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 125.2076 117.128) (end 125.2076 118.3642) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 120 125.9) (end 116.584998 125.9) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 114.095313 128.389685) (end 110.610315 128.389685) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 116.584998 125.9) (end 114.095313 128.389685) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 110.610315 128.389685) (end 105.079507 133.920493) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 105.079507 133.933679) (end 105.079507 133.920493) (width 0.25) (layer B.Cu) (net 87)) + (via (at 105.132534 133.97352) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 87)) + (segment (start 105.079507 133.933679) (end 105.092693 133.933679) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 105.092693 133.933679) (end 105.132534 133.97352) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 105.113471 133.97352) (end 103.430912 132.290961) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 105.132534 133.97352) (end 105.113471 133.97352) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 104.013186 135) (end 105.079507 133.933679) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 103.2 135) (end 104.013186 135) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 101.915367 133.165961) (end 101.915367 133.715367) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 101.915367 133.715367) (end 103.2 135) (width 0.25) (layer B.Cu) (net 87)) + (segment (start 125.2584 118.415) (end 125.2584 124.639588) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 120.199999 125.700001) (end 120 125.9) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 124.197987 125.700001) (end 120.199999 125.700001) (width 0.25) (layer F.Cu) (net 87)) + (segment (start 125.2584 124.639588) (end 124.197987 125.700001) (width 0.25) (layer F.Cu) (net 87)) + (via (at 161.45 94.69) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) + (segment (start 161.45 95.365) (end 161 95.815) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 161.45 94.69) (end 161.45 95.365) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 163.3 95.976812) (end 162.013188 94.69) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 163.3 96.99) (end 163.3 95.976812) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 162.013188 94.69) (end 161.45 94.69) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 161 97.565) (end 162.725 97.565) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 162.725 97.565) (end 163.3 96.99) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 129.508404 114.442789) (end 129.449194 114.44279) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 129.508404 114.366588) (end 129.508404 114.442789) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 129.508404 114.366588) (end 126 117.874992) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 126 117.874992) (end 117.125008 117.874992) (width 0.25) (layer F.Cu) (net 88)) + (via (at 112.5 124) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) + (segment (start 113.631807 122.863389) (end 113.631807 122.868193) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 113.631807 122.868193) (end 112.5 124) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 112.5 124) (end 112.5 124.3) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 112.753759 124.553759) (end 114.08474 124.553759) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 112.5 124.3) (end 112.753759 124.553759) (width 0.25) (layer F.Cu) (net 88)) + (via (at 116.1 119.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) + (segment (start 113.631807 122.863389) (end 113.223559 122.455141) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 114.877217 119.8) (end 116.1 119.8) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 113.223559 121.453658) (end 114.877217 119.8) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 113.223559 122.455141) (end 113.223559 121.453658) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 116.1 118.9) (end 116.65 118.35) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 116.1 119.8) (end 116.1 118.9) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 117.125008 117.874992) (end 116.65 118.35) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 116.65 118.35) (end 116.33227 118.66773) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 160.8 94.04) (end 161.45 94.69) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 147.9355 100.54) (end 148 100.54) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 148 100.54) (end 149.974999 98.565001) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 146.812 101.6635) (end 147.9355 100.54) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 149.974999 98.565001) (end 150.252001 98.565001) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 146.812 111.41918) (end 146.812 101.6635) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 154.777002 94.04) (end 160.8 94.04) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 150.252001 98.565001) (end 154.777002 94.04) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 135.326612 114.366588) (end 135.69061 114.00259) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 144.22859 114.00259) (end 146.812 111.41918) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 135.69061 114.00259) (end 144.22859 114.00259) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 129.508404 114.366588) (end 135.326612 114.366588) (width 0.25) (layer F.Cu) (net 88)) + (via (at 173.5 99.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (via (at 143.4702 117.4498) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (segment (start 142.0248 117.4498) (end 141.9 117.325) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 143.4702 117.4498) (end 142.0248 117.4498) (width 0.25) (layer F.Cu) (net 89)) + (via (at 165.949996 113.63141) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (segment (start 143.95801 117.93761) (end 143.4702 117.4498) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 141.9 119.075) (end 141.95451 119.12951) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 143.621178 119.12951) (end 143.95801 118.792678) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 141.95451 119.12951) (end 143.621178 119.12951) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 143.95801 118.792678) (end 143.95801 117.93761) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 173.5 98.915) (end 173.5 99.15) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 175.2 98.325) (end 174.09 98.325) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 174.09 98.325) (end 173.5 98.915) (width 0.25) (layer B.Cu) (net 89)) + (via (at 147.1222 121.4828) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) + (segment (start 143.4702 117.4498) (end 143.894511 117.874111) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 143.894511 118.255111) (end 147.1222 121.4828) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 143.894511 117.874111) (end 143.894511 118.255111) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 160.949249 118.914999) (end 154.586411 118.914999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 154.586411 118.914999) (end 153.486411 120.014999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 153.486411 120.014999) (end 152.529214 120.014999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 147.405042 121.4828) (end 147.1222 121.4828) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 152.529214 120.014999) (end 151.061413 121.4828) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 151.061413 121.4828) (end 147.405042 121.4828) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 165.949996 113.914252) (end 160.949249 118.914999) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 165.949996 113.63141) (end 165.949996 113.914252) (width 0.25) (layer B.Cu) (net 89)) + (segment (start 173.699999 99.349999) (end 173.5 99.15) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 173.699999 100.013187) (end 173.699999 99.349999) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 167 112.581406) (end 167 104.464998) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 165.949996 113.63141) (end 167 112.581406) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 170.813186 102.9) (end 173.699999 100.013187) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 167 104.464998) (end 168.564998 102.9) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 168.564998 102.9) (end 170.813186 102.9) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 173.761812 100.075) (end 173.699999 100.013187) (width 0.25) (layer F.Cu) (net 89)) + (segment (start 175.2 100.075) (end 173.761812 100.075) (width 0.25) (layer F.Cu) (net 89)) + (via (at 200.75 103.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 200.125 103.125) (end 199.1 103.125) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 200.75 103.75) (end 200.125 103.125) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 199.1 106.325008) (end 198.249998 107.17501) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 188.214987 107.100011) (end 198.174999 107.100011) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 198.174999 107.100011) (end 198.249998 107.17501) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 199.1 104.875) (end 199.1 106.325008) (width 0.25) (layer B.Cu) (net 90)) + (via (at 198.249998 107.17501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 185.95001 109.364988) (end 188.214987 107.100011) (width 0.25) (layer F.Cu) (net 90)) + (via (at 154.7986 116.0782) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 154.7986 115.3162) (end 154.7986 116.0782) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.2 114.915) (end 155.1998 114.915) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 155.1998 114.915) (end 154.7986 115.3162) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.172 116.637) (end 156.2 116.665) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 155.0018 116.637) (end 156.172 116.637) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 154.7986 116.0782) (end 154.7986 116.4338) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 154.7986 116.4338) (end 155.0018 116.637) (width 0.25) (layer F.Cu) (net 90)) + (via (at 184.633532 112.308932) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 90)) + (segment (start 200.75 104.3675) (end 200.75 103.75) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 199.1 104.875) (end 200.2425 104.875) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 200.2425 104.875) (end 200.75 104.3675) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.2 113.620901) (end 156.714501 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.272622 113.15641) (end 163.748978 113.15641) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.748978 113.15641) (end 163.798988 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 183.836064 113.1064) (end 184.633532 112.308932) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.714501 113.1064) (end 163.222612 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.798988 113.1064) (end 183.836064 113.1064) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 156.2 114.915) (end 156.2 113.620901) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 163.222612 113.1064) (end 163.272622 113.15641) (width 0.25) (layer B.Cu) (net 90)) + (segment (start 185.95001 109.364988) (end 185.95001 110.992454) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 185.95001 110.992454) (end 185.847332 111.095132) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 184.633532 112.308932) (end 185.847332 111.095132) (width 0.25) (layer F.Cu) (net 90)) + (segment (start 180 117.425) (end 180.5594 116.8656) (width 0.25) (layer F.Cu) (net 91)) + (via (at 181.7734 118.2626) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 91)) + (segment (start 181.7734 117.221396) (end 181.7734 118.2626) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 180.5594 116.8656) (end 181.417604 116.8656) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 181.417604 116.8656) (end 181.7734 117.221396) (width 0.25) (layer F.Cu) (net 91)) + (via (at 183.5768 118.1102) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 91)) + (segment (start 183.4244 118.2626) (end 183.5768 118.1102) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.7734 118.2626) (end 183.4244 118.2626) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.1165 119.175) (end 180 119.175) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.7734 118.2626) (end 181.7734 118.5181) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 181.7734 118.5181) (end 181.1165 119.175) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 183.5768 117.986002) (end 183.5768 118.1102) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 212.925 104.875) (end 206.502 111.298) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 185.103602 116.4592) (end 183.5768 117.986002) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.35 104.875) (end 212.925 104.875) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 206.502 113.3475) (end 203.3903 116.4592) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 206.502 111.298) (end 206.502 113.3475) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 203.3903 116.4592) (end 185.103602 116.4592) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.35 104.875) (end 213.07501 104.875) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.35 103.125) (end 213.17501 103.125) (width 0.25) (layer B.Cu) (net 91)) + (segment (start 213.07501 104.875) (end 212.25001 104.05) (width 0.25) (layer F.Cu) (net 91)) + (segment (start 213.17501 103.125) (end 212.25001 104.05) (width 0.25) (layer B.Cu) (net 91)) + (via (at 212.25001 104.05) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 91)) + (via (at 98.5092 126.9858) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 99.882673 126.9858) (end 98.5092 126.9858) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 101.030912 128.134039) (end 99.882673 126.9858) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 98.5092 126.9858) (end 98.2 127.295) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 98.2 127.693672) (end 99.515367 129.009039) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 98.2 127.295) (end 98.2 127.693672) (width 0.25) (layer F.Cu) (net 92)) + (via (at 110.3 127.1) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 116.858981 125.626017) (end 116.95608 125.6) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 110.3 127.1) (end 115.384998 127.1) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 115.384998 127.1) (end 116.858981 125.626017) (width 0.25) (layer F.Cu) (net 92)) + (via (at 119.8 124.8) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 116.95608 125.6) (end 119 125.6) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 119 125.6) (end 119.8 124.8) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 119.8 124.390243) (end 118.721184 123.311427) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 119.8 124.8) (end 119.8 124.390243) (width 0.25) (layer B.Cu) (net 92)) + (via (at 120 122.2) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 92)) + (segment (start 118.721184 123.311427) (end 118.888573 123.311427) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 118.888573 123.311427) (end 120 122.2) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 118.847194 122.2) (end 118.268251 121.621057) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 120 122.2) (end 118.847194 122.2) (width 0.25) (layer F.Cu) (net 92)) + (segment (start 107.1 127.1) (end 110.3 127.1) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 106.580662 127.619338) (end 107.1 127.1) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 101.030912 128.134039) (end 101.545613 127.619338) (width 0.25) (layer B.Cu) (net 92)) + (segment (start 101.545613 127.619338) (end 106.580662 127.619338) (width 0.25) (layer B.Cu) (net 92)) + (via (at 135.6216 117.9578) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 137.1 119.075) (end 136.7388 119.075) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 136.7388 119.075) (end 135.6216 117.9578) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 136.4672 117.9578) (end 137.1 117.325) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 135.6216 117.9578) (end 136.4672 117.9578) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 137.1 116.033901) (end 137.584711 115.54919) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 137.1 117.325) (end 137.1 116.033901) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 137.584711 115.54919) (end 137.64921 115.54919) (width 0.25) (layer B.Cu) (net 93)) + (via (at 141.3112 115.0114) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 137.64921 115.54919) (end 138.187 115.0114) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 138.187 115.0114) (end 141.3112 115.0114) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 161 113.1864) (end 160.8438 113.0302) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 160.8438 113.0302) (end 154.6862 113.0302) (width 0.25) (layer F.Cu) (net 93)) + (via (at 154.6862 113.0302) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 161 114.915) (end 161 113.1864) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 152.4633 113.0302) (end 152.4 113.0935) (width 0.25) (layer B.Cu) (net 93)) + (via (at 152.4 113.0935) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 141.3112 115.0114) (end 150.4821 115.0114) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 154.6862 113.0302) (end 152.4633 113.0302) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 150.4821 115.0114) (end 152.4 113.0935) (width 0.25) (layer F.Cu) (net 93)) + (via (at 162.493589 114.386621) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 93)) + (segment (start 163.2 116.013188) (end 163.2 115.093032) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 162.548188 116.665) (end 163.2 116.013188) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 163.2 115.093032) (end 162.493589 114.386621) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 161 116.665) (end 162.548188 116.665) (width 0.25) (layer B.Cu) (net 93)) + (segment (start 161.96521 114.915) (end 162.493589 114.386621) (width 0.25) (layer F.Cu) (net 93)) + (segment (start 161 114.915) (end 161.96521 114.915) (width 0.25) (layer F.Cu) (net 93)) + (via (at 181.113 120.2438) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 94)) + (segment (start 181.113 120.788) (end 181.113 120.2438) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 182.85 121.195) (end 181.52 121.195) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 181.52 121.195) (end 181.113 120.788) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 178.9051 114.7066) (end 178.827 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.2435 119.445) (end 182.85 119.445) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 181.113 120.2438) (end 181.4447 120.2438) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 181.4447 120.2438) (end 182.2435 119.445) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 175.2 115.8336) (end 175.2 117.425) (width 0.25) (layer B.Cu) (net 94)) + (via (at 173.8232 118.288) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 94)) + (segment (start 173.8232 118.288) (end 174.041 118.288) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 174.928 119.175) (end 175.2 119.175) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 174.041 118.288) (end 174.928 119.175) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 174.0081 118.288) (end 173.8232 118.288) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 175.2 117.425) (end 174.8711 117.425) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 174.8711 117.425) (end 174.0081 118.288) (width 0.25) (layer B.Cu) (net 94)) + (segment (start 176.327 114.7066) (end 175.2 115.8336) (width 0.25) (layer F.Cu) (net 94)) + (via (at 175.2 115.8336) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 94)) + (segment (start 178.9051 114.7066) (end 176.327 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 185.4454 110.409602) (end 185.4454 100.1522) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 178.9051 114.7066) (end 181.148402 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 183.119201 112.735801) (end 185.4454 110.409602) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 181.148402 114.7066) (end 183.119201 112.735801) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.85 113.005002) (end 183.119201 112.735801) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.85 116.408198) (end 181.148402 114.7066) (width 0.25) (layer F.Cu) (net 94)) + (segment (start 182.85 119.445) (end 182.85 116.408198) (width 0.25) (layer F.Cu) (net 94)) + + (zone (net 34) (net_name GND) (layer F.Cu) (tstamp 6039FDAD) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508) (smoothing chamfer)) + (polygon + (pts + (xy 80.95 127.2) (xy 92.9 147.65) (xy 138 134.95) (xy 157.25 135.05) (xy 187.45 134.85) + (xy 225.9 121.5) (xy 226 42.8) (xy 171.7 34.3) (xy 87.45 36.6) (xy 87.8 115) + ) + ) + (filled_polygon + (pts + (xy 224.336807 44.116746) (xy 224.447617 44.145115) (xy 224.521481 44.178972) (xy 224.587585 44.224767) (xy 224.644771 44.281261) + (xy 224.691436 44.346768) (xy 224.726105 44.419343) (xy 224.747732 44.497657) (xy 224.758192 44.613012) (xy 224.785002 119.001646) + (xy 215.240448 122.646508) (xy 214.443004 120.569096) (xy 187.241582 131.010743) (xy 188.020945 133.041054) (xy 187.30358 133.315) + (xy 138.158838 133.315) (xy 138.096265 133.314123) (xy 138.058284 133.321126) (xy 138.019845 133.324912) (xy 137.959927 133.343088) + (xy 93.864605 146.047335) (xy 93.520432 145.984758) (xy 93.243912 145.892584) (xy 93.08499 145.756366) (xy 82.933274 128.127044) + (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583074 116.011918) + (xy 88.59798 115.990873) (xy 88.615021 115.952706) (xy 88.618829 115.945648) (xy 88.62876 115.921935) (xy 88.639207 115.898536) + (xy 88.641735 115.890952) (xy 88.657891 115.852374) (xy 88.663024 115.827087) (xy 88.84031 115.29523) (xy 88.855164 115.261034) + (xy 88.868713 115.198522) (xy 88.882908 115.13609) (xy 88.883923 115.098817) (xy 88.948633 114.539922) (xy 88.950347 114.53427) + (xy 88.956379 114.473019) (xy 88.959581 114.44536) (xy 88.959682 114.439478) (xy 88.960257 114.433634) (xy 88.960256 114.405836) + (xy 88.961309 114.344252) (xy 88.960255 114.338437) (xy 88.96016 109.1) (xy 97.761928 109.1) (xy 97.761928 111.1) + (xy 97.774188 111.224482) (xy 97.810498 111.34418) (xy 97.869463 111.454494) (xy 97.948815 111.551185) (xy 98.045506 111.630537) + (xy 98.15582 111.689502) (xy 98.275518 111.725812) (xy 98.4 111.738072) (xy 101.6 111.738072) (xy 101.724482 111.725812) + (xy 101.84418 111.689502) (xy 101.954494 111.630537) (xy 102.051185 111.551185) (xy 102.130537 111.454494) (xy 102.189502 111.34418) + (xy 102.225812 111.224482) (xy 102.238072 111.1) (xy 102.238072 109.1) (xy 102.225812 108.975518) (xy 102.189502 108.85582) + (xy 102.130537 108.745506) (xy 102.051185 108.648815) (xy 101.954494 108.569463) (xy 101.84418 108.510498) (xy 101.724482 108.474188) + (xy 101.6 108.461928) (xy 98.4 108.461928) (xy 98.275518 108.474188) (xy 98.15582 108.510498) (xy 98.045506 108.569463) + (xy 97.948815 108.648815) (xy 97.869463 108.745506) (xy 97.810498 108.85582) (xy 97.774188 108.975518) (xy 97.761928 109.1) + (xy 88.96016 109.1) (xy 88.960118 106.838967) (xy 90.865 106.838967) (xy 90.865 107.161033) (xy 90.927832 107.476912) + (xy 91.051082 107.774463) (xy 91.230013 108.042252) (xy 91.457748 108.269987) (xy 91.725537 108.448918) (xy 92.023088 108.572168) + (xy 92.338967 108.635) (xy 92.661033 108.635) (xy 92.976912 108.572168) (xy 93.274463 108.448918) (xy 93.542252 108.269987) + (xy 93.769987 108.042252) (xy 93.948918 107.774463) (xy 94.072168 107.476912) (xy 94.135 107.161033) (xy 94.135 106.838967) + (xy 105.365 106.838967) (xy 105.365 107.161033) (xy 105.427832 107.476912) (xy 105.551082 107.774463) (xy 105.730013 108.042252) + (xy 105.957748 108.269987) (xy 106.225537 108.448918) (xy 106.523088 108.572168) (xy 106.838967 108.635) (xy 107.161033 108.635) + (xy 107.476912 108.572168) (xy 107.774463 108.448918) (xy 108.042252 108.269987) (xy 108.269987 108.042252) (xy 108.448918 107.774463) + (xy 108.572168 107.476912) (xy 108.635 107.161033) (xy 108.635 106.838967) (xy 108.572168 106.523088) (xy 108.448918 106.225537) + (xy 108.269987 105.957748) (xy 108.042252 105.730013) (xy 107.774463 105.551082) (xy 107.476912 105.427832) (xy 107.161033 105.365) + (xy 106.838967 105.365) (xy 106.523088 105.427832) (xy 106.225537 105.551082) (xy 105.957748 105.730013) (xy 105.730013 105.957748) + (xy 105.551082 106.225537) (xy 105.427832 106.523088) (xy 105.365 106.838967) (xy 94.135 106.838967) (xy 94.072168 106.523088) + (xy 93.948918 106.225537) (xy 93.769987 105.957748) (xy 93.542252 105.730013) (xy 93.445065 105.665075) (xy 93.455808 105.635413) + (xy 92.5 104.679605) (xy 91.544192 105.635413) (xy 91.554935 105.665075) (xy 91.457748 105.730013) (xy 91.230013 105.957748) + (xy 91.051082 106.225537) (xy 90.927832 106.523088) (xy 90.865 106.838967) (xy 88.960118 106.838967) (xy 88.960076 104.562595) + (xy 90.858282 104.562595) (xy 90.902039 104.881675) (xy 91.007205 105.186088) (xy 91.100186 105.360044) (xy 91.364587 105.455808) + (xy 92.320395 104.5) (xy 92.679605 104.5) (xy 93.635413 105.455808) (xy 93.899814 105.360044) (xy 94.040704 105.070429) + (xy 94.122384 104.758892) (xy 94.141718 104.437405) (xy 94.097961 104.118325) (xy 93.992795 103.813912) (xy 93.899814 103.639956) + (xy 93.635413 103.544192) (xy 92.679605 104.5) (xy 92.320395 104.5) (xy 91.364587 103.544192) (xy 91.100186 103.639956) + (xy 90.959296 103.929571) (xy 90.877616 104.241108) (xy 90.858282 104.562595) (xy 88.960076 104.562595) (xy 88.960026 101.838967) + (xy 90.865 101.838967) (xy 90.865 102.161033) (xy 90.927832 102.476912) (xy 91.051082 102.774463) (xy 91.230013 103.042252) + (xy 91.457748 103.269987) (xy 91.554935 103.334925) (xy 91.544192 103.364587) (xy 92.5 104.320395) (xy 93.455808 103.364587) + (xy 93.445065 103.334925) (xy 93.542252 103.269987) (xy 93.769987 103.042252) (xy 93.948918 102.774463) (xy 94.072168 102.476912) + (xy 94.135 102.161033) (xy 94.135 101.838967) (xy 94.072168 101.523088) (xy 93.948918 101.225537) (xy 93.769987 100.957748) + (xy 93.542252 100.730013) (xy 93.274463 100.551082) (xy 92.976912 100.427832) (xy 92.661033 100.365) (xy 92.338967 100.365) + (xy 92.023088 100.427832) (xy 91.725537 100.551082) (xy 91.457748 100.730013) (xy 91.230013 100.957748) (xy 91.051082 101.225537) + (xy 90.927832 101.523088) (xy 90.865 101.838967) (xy 88.960026 101.838967) (xy 88.959953 97.9) (xy 97.761928 97.9) + (xy 97.761928 99.9) (xy 97.774188 100.024482) (xy 97.810498 100.14418) (xy 97.869463 100.254494) (xy 97.948815 100.351185) + (xy 98.045506 100.430537) (xy 98.15582 100.489502) (xy 98.275518 100.525812) (xy 98.4 100.538072) (xy 101.6 100.538072) + (xy 101.724482 100.525812) (xy 101.84418 100.489502) (xy 101.954494 100.430537) (xy 102.051185 100.351185) (xy 102.130537 100.254494) + (xy 102.189502 100.14418) (xy 102.225812 100.024482) (xy 102.238072 99.9) (xy 102.238072 97.9) (xy 102.225812 97.775518) + (xy 102.189502 97.65582) (xy 102.130537 97.545506) (xy 102.051185 97.448815) (xy 101.954494 97.369463) (xy 101.84418 97.310498) + (xy 101.724482 97.274188) (xy 101.6 97.261928) (xy 98.4 97.261928) (xy 98.275518 97.274188) (xy 98.15582 97.310498) + (xy 98.045506 97.369463) (xy 97.948815 97.448815) (xy 97.869463 97.545506) (xy 97.810498 97.65582) (xy 97.774188 97.775518) + (xy 97.761928 97.9) (xy 88.959953 97.9) (xy 88.959885 94.236545) (xy 88.966261 94.268601) (xy 89.164893 94.748141) + (xy 89.453262 95.179715) (xy 89.820285 95.546738) (xy 90.251859 95.835107) (xy 90.731399 96.033739) (xy 91.240475 96.135) + (xy 91.759525 96.135) (xy 92.268601 96.033739) (xy 92.748141 95.835107) (xy 93.179715 95.546738) (xy 93.546738 95.179715) + (xy 93.835107 94.748141) (xy 94.033739 94.268601) (xy 94.135 93.759525) (xy 94.135 93.240475) (xy 94.033739 92.731399) + (xy 93.835107 92.251859) (xy 93.546738 91.820285) (xy 93.179715 91.453262) (xy 92.748141 91.164893) (xy 92.268601 90.966261) + (xy 92.095535 90.931836) (xy 92.271034 90.878599) (xy 92.529014 90.740706) (xy 92.755134 90.555134) (xy 92.800624 90.499705) + (xy 92.969381 90.664176) (xy 93.214382 90.823361) (xy 93.485731 90.93169) (xy 93.773 90.985) (xy 94.173 90.985) + (xy 94.173 89.627) (xy 94.427 89.627) (xy 94.427 90.985) (xy 94.827 90.985) (xy 95.114269 90.93169) + (xy 95.385618 90.823361) (xy 95.630619 90.664176) (xy 95.839857 90.460252) (xy 96.005291 90.219426) (xy 96.120563 89.950953) + (xy 96.141476 89.85689) (xy 96.020155 89.627) (xy 94.427 89.627) (xy 94.173 89.627) (xy 94.153 89.627) + (xy 94.153 89.373) (xy 94.173 89.373) (xy 94.173 88.015) (xy 94.427 88.015) (xy 94.427 89.373) + (xy 96.020155 89.373) (xy 96.141476 89.14311) (xy 96.120563 89.049047) (xy 96.005291 88.780574) (xy 95.839857 88.539748) + (xy 95.630619 88.335824) (xy 95.385618 88.176639) (xy 95.114269 88.06831) (xy 94.827 88.015) (xy 94.427 88.015) + (xy 94.173 88.015) (xy 93.773 88.015) (xy 93.485731 88.06831) (xy 93.214382 88.176639) (xy 92.969381 88.335824) + (xy 92.800624 88.500295) (xy 92.755134 88.444866) (xy 92.529014 88.259294) (xy 92.271034 88.121401) (xy 92.06 88.057384) + (xy 92.06 84.992616) (xy 92.271034 84.928599) (xy 92.529014 84.790706) (xy 92.755134 84.605134) (xy 92.800624 84.549705) + (xy 92.969381 84.714176) (xy 93.214382 84.873361) (xy 93.485731 84.98169) (xy 93.773 85.035) (xy 94.173 85.035) + (xy 94.173 83.677) (xy 94.427 83.677) (xy 94.427 85.035) (xy 94.827 85.035) (xy 95.114269 84.98169) + (xy 95.385618 84.873361) (xy 95.630619 84.714176) (xy 95.839857 84.510252) (xy 96.005291 84.269426) (xy 96.120563 84.000953) + (xy 96.141476 83.90689) (xy 96.020155 83.677) (xy 94.427 83.677) (xy 94.173 83.677) (xy 94.153 83.677) + (xy 94.153 83.423) (xy 94.173 83.423) (xy 94.173 83.403) (xy 94.427 83.403) (xy 94.427 83.423) + (xy 96.020155 83.423) (xy 96.141476 83.19311) (xy 96.128554 83.13499) (xy 96.474071 83.13499) (xy 96.436487 83.258889) + (xy 96.407815 83.55) (xy 96.436487 83.841111) (xy 96.521401 84.121034) (xy 96.659294 84.379014) (xy 96.701935 84.430972) + (xy 96.621637 84.415) (xy 96.378363 84.415) (xy 96.139764 84.46246) (xy 95.915008 84.555557) (xy 95.712733 84.690713) + (xy 95.540713 84.862733) (xy 95.405557 85.065008) (xy 95.31246 85.289764) (xy 95.265 85.528363) (xy 95.265 85.771637) + (xy 95.31246 86.010236) (xy 95.405557 86.234992) (xy 95.540713 86.437267) (xy 95.628446 86.525) (xy 95.540713 86.612733) + (xy 95.405557 86.815008) (xy 95.31246 87.039764) (xy 95.265 87.278363) (xy 95.265 87.521637) (xy 95.31246 87.760236) + (xy 95.405557 87.984992) (xy 95.540713 88.187267) (xy 95.712733 88.359287) (xy 95.915008 88.494443) (xy 96.139764 88.58754) + (xy 96.378363 88.635) (xy 96.621637 88.635) (xy 96.701935 88.619028) (xy 96.659294 88.670986) (xy 96.521401 88.928966) + (xy 96.436487 89.208889) (xy 96.407815 89.5) (xy 96.436487 89.791111) (xy 96.521401 90.071034) (xy 96.659294 90.329014) + (xy 96.844866 90.555134) (xy 97.070986 90.740706) (xy 97.328966 90.878599) (xy 97.608889 90.963513) (xy 97.82705 90.985) + (xy 98.77295 90.985) (xy 98.991111 90.963513) (xy 99.271034 90.878599) (xy 99.529014 90.740706) (xy 99.755134 90.555134) + (xy 99.940706 90.329014) (xy 100.078599 90.071034) (xy 100.163513 89.791111) (xy 100.192185 89.5) (xy 100.166085 89.235) + (xy 100.27295 89.235) (xy 100.491111 89.213513) (xy 100.771034 89.128599) (xy 101.029014 88.990706) (xy 101.255134 88.805134) + (xy 101.440706 88.579014) (xy 101.578599 88.321034) (xy 101.663513 88.041111) (xy 101.679873 87.875) (xy 101.911928 87.875) + (xy 101.924188 87.999482) (xy 101.960498 88.11918) (xy 102.019463 88.229494) (xy 102.098815 88.326185) (xy 102.195506 88.405537) + (xy 102.30582 88.464502) (xy 102.425518 88.500812) (xy 102.55 88.513072) (xy 103.26425 88.51) (xy 103.423 88.35125) + (xy 103.423 87.502) (xy 103.677 87.502) (xy 103.677 88.35125) (xy 103.83575 88.51) (xy 104.55 88.513072) + (xy 104.674482 88.500812) (xy 104.79418 88.464502) (xy 104.904494 88.405537) (xy 105.001185 88.326185) (xy 105.080537 88.229494) + (xy 105.139502 88.11918) (xy 105.175812 87.999482) (xy 105.188072 87.875) (xy 105.185 87.66075) (xy 105.02625 87.502) + (xy 103.677 87.502) (xy 103.423 87.502) (xy 102.07375 87.502) (xy 101.915 87.66075) (xy 101.911928 87.875) + (xy 101.679873 87.875) (xy 101.692185 87.75) (xy 101.663513 87.458889) (xy 101.578599 87.178966) (xy 101.440706 86.920986) + (xy 101.255134 86.694866) (xy 101.048152 86.525) (xy 101.255134 86.355134) (xy 101.440706 86.129014) (xy 101.578599 85.871034) + (xy 101.663513 85.591111) (xy 101.692185 85.3) (xy 101.663513 85.008889) (xy 101.640797 84.934004) (xy 103.211003 83.363799) + (xy 103.240001 83.340001) (xy 103.277705 83.294059) (xy 103.334974 83.224277) (xy 103.405546 83.092247) (xy 103.415571 83.059197) + (xy 103.449003 82.948986) (xy 103.46 82.837333) (xy 103.46 82.837323) (xy 103.463676 82.8) (xy 103.46 82.762677) + (xy 103.46 81.395971) (xy 103.550057 81.335797) (xy 103.735797 81.150057) (xy 103.881732 80.931649) (xy 103.982254 80.688968) + (xy 104.0335 80.431338) (xy 104.0335 80.168662) (xy 103.982254 79.911032) (xy 103.881732 79.668351) (xy 103.785798 79.524775) + (xy 103.843468 79.595046) (xy 103.843471 79.595049) (xy 103.871184 79.628817) (xy 103.904951 79.656529) (xy 105.604953 81.356532) + (xy 105.604959 81.356537) (xy 105.74 81.491578) (xy 105.739999 82.64) (xy 105.024822 82.64) (xy 104.9875 82.636324) + (xy 104.950177 82.64) (xy 104.950167 82.64) (xy 104.838514 82.650997) (xy 104.709936 82.69) (xy 104.695253 82.694454) + (xy 104.563223 82.765026) (xy 104.492144 82.82336) (xy 104.447499 82.859999) (xy 104.423701 82.888997) (xy 103.038998 84.273701) + (xy 103.01 84.297499) (xy 102.986202 84.326497) (xy 102.986201 84.326498) (xy 102.915026 84.413224) (xy 102.87563 84.486928) + (xy 102.55 84.486928) (xy 102.425518 84.499188) (xy 102.30582 84.535498) (xy 102.195506 84.594463) (xy 102.098815 84.673815) + (xy 102.019463 84.770506) (xy 101.960498 84.88082) (xy 101.924188 85.000518) (xy 101.911928 85.125) (xy 101.911928 86.125) + (xy 101.924188 86.249482) (xy 101.960498 86.36918) (xy 102.019463 86.479494) (xy 102.036292 86.5) (xy 102.019463 86.520506) + (xy 101.960498 86.63082) (xy 101.924188 86.750518) (xy 101.911928 86.875) (xy 101.915 87.08925) (xy 102.07375 87.248) + (xy 103.423 87.248) (xy 103.423 87.228) (xy 103.677 87.228) (xy 103.677 87.248) (xy 104.316165 87.248) + (xy 104.460683 87.307861) (xy 104.622003 87.33995) (xy 104.786483 87.33995) (xy 104.947803 87.307861) (xy 105.099764 87.244917) + (xy 105.236524 87.153537) (xy 105.35283 87.037231) (xy 105.44421 86.900471) (xy 105.507154 86.74851) (xy 105.515001 86.709063) + (xy 105.515001 87.243477) (xy 105.527806 87.37349) (xy 105.578412 87.540313) (xy 105.66059 87.694059) (xy 105.771184 87.828817) + (xy 105.905942 87.939411) (xy 106.059688 88.021589) (xy 106.226511 88.072195) (xy 106.349933 88.084351) (xy 106.360498 88.11918) + (xy 106.419463 88.229494) (xy 106.498815 88.326185) (xy 106.595506 88.405537) (xy 106.70582 88.464502) (xy 106.825518 88.500812) + (xy 106.95 88.513072) (xy 108.95 88.513072) (xy 108.99 88.509132) (xy 108.990001 91.763548) (xy 108.679715 91.453262) + (xy 108.248141 91.164893) (xy 107.768601 90.966261) (xy 107.259525 90.865) (xy 106.740475 90.865) (xy 106.231399 90.966261) + (xy 105.751859 91.164893) (xy 105.320285 91.453262) (xy 104.953262 91.820285) (xy 104.664893 92.251859) (xy 104.466261 92.731399) + (xy 104.365 93.240475) (xy 104.365 93.759525) (xy 104.466261 94.268601) (xy 104.664893 94.748141) (xy 104.953262 95.179715) + (xy 105.320285 95.546738) (xy 105.751859 95.835107) (xy 105.877579 95.887182) (xy 105.875 95.886928) (xy 104.575 95.886928) + (xy 104.450518 95.899188) (xy 104.33082 95.935498) (xy 104.220506 95.994463) (xy 104.123815 96.073815) (xy 104.044463 96.170506) + (xy 103.985498 96.28082) (xy 103.949188 96.400518) (xy 103.936928 96.525) (xy 103.936928 97.475) (xy 103.949188 97.599482) + (xy 103.985498 97.71918) (xy 104.044463 97.829494) (xy 104.123815 97.926185) (xy 104.220506 98.005537) (xy 104.33082 98.064502) + (xy 104.450518 98.100812) (xy 104.575 98.113072) (xy 105.490001 98.113072) (xy 105.490001 98.212668) (xy 105.486324 98.25) + (xy 105.490001 98.287333) (xy 105.500998 98.398986) (xy 105.503801 98.408225) (xy 105.544454 98.542246) (xy 105.615026 98.674276) + (xy 105.683303 98.757471) (xy 105.71 98.790001) (xy 105.738998 98.813799) (xy 107.322271 100.397072) (xy 107.161033 100.365) + (xy 106.838967 100.365) (xy 106.523088 100.427832) (xy 106.225537 100.551082) (xy 105.957748 100.730013) (xy 105.730013 100.957748) + (xy 105.551082 101.225537) (xy 105.427832 101.523088) (xy 105.365 101.838967) (xy 105.365 102.161033) (xy 105.427832 102.476912) + (xy 105.551082 102.774463) (xy 105.730013 103.042252) (xy 105.957748 103.269987) (xy 106.225537 103.448918) (xy 106.523088 103.572168) + (xy 106.838967 103.635) (xy 107.161033 103.635) (xy 107.476912 103.572168) (xy 107.774463 103.448918) (xy 108.042252 103.269987) + (xy 108.269987 103.042252) (xy 108.448918 102.774463) (xy 108.572168 102.476912) (xy 108.635 102.161033) (xy 108.635 101.838967) + (xy 108.602928 101.67773) (xy 109.24 102.314802) (xy 109.240001 118.959797) (xy 109.220376 118.979422) (xy 109.116779 119.022333) + (xy 108.980019 119.113713) (xy 108.863713 119.230019) (xy 108.772333 119.366779) (xy 108.729421 119.470377) (xy 108.688071 119.511728) + (xy 107.9998 119.511728) (xy 107.875318 119.523988) (xy 107.75562 119.560298) (xy 107.645306 119.619263) (xy 107.548615 119.698615) + (xy 107.469263 119.795306) (xy 107.432117 119.8648) (xy 106.412522 119.8648) (xy 106.375199 119.861124) (xy 106.337876 119.8648) + (xy 106.337867 119.8648) (xy 106.226214 119.875797) (xy 106.082953 119.919254) (xy 105.950924 119.989826) (xy 105.934885 120.002989) + (xy 105.864196 120.061001) (xy 105.864192 120.061005) (xy 105.835199 120.084799) (xy 105.811405 120.113792) (xy 105.740027 120.18517) + (xy 105.870288 119.870692) (xy 105.985 119.293997) (xy 105.985 118.706003) (xy 105.870288 118.129308) (xy 105.645273 117.586072) + (xy 105.318601 117.097174) (xy 104.902826 116.681399) (xy 104.413928 116.354727) (xy 103.870692 116.129712) (xy 103.293997 116.015) + (xy 102.706003 116.015) (xy 102.129308 116.129712) (xy 101.586072 116.354727) (xy 101.097174 116.681399) (xy 100.681399 117.097174) + (xy 100.354727 117.586072) (xy 100.129712 118.129308) (xy 100.015 118.706003) (xy 100.015 119.293997) (xy 100.129712 119.870692) + (xy 100.354727 120.413928) (xy 100.681399 120.902826) (xy 101.097174 121.318601) (xy 101.586072 121.645273) (xy 102.116059 121.8648) + (xy 100.994489 121.8648) (xy 100.948986 121.850997) (xy 100.837333 121.84) (xy 100.837322 121.84) (xy 100.8 121.836324) + (xy 100.762678 121.84) (xy 100.547157 121.84) (xy 100.44356 121.797089) (xy 100.28224 121.765) (xy 100.11776 121.765) + (xy 99.95644 121.797089) (xy 99.804479 121.860033) (xy 99.769769 121.883226) (xy 99.732753 121.894454) (xy 99.600724 121.965026) + (xy 99.484999 122.059999) (xy 99.461201 122.088997) (xy 99.06327 122.486928) (xy 98.375 122.486928) (xy 98.250518 122.499188) + (xy 98.13082 122.535498) (xy 98.020506 122.594463) (xy 97.923815 122.673815) (xy 97.844463 122.770506) (xy 97.785498 122.88082) + (xy 97.749188 123.000518) (xy 97.736928 123.125) (xy 97.736928 124.075) (xy 97.749188 124.199482) (xy 97.785498 124.31918) + (xy 97.844463 124.429494) (xy 97.923815 124.526185) (xy 98.020506 124.605537) (xy 98.13082 124.664502) (xy 98.230467 124.69473) + (xy 96.599199 126.326) (xy 96.123323 126.326) (xy 96.086 126.322324) (xy 96.048677 126.326) (xy 96.048667 126.326) + (xy 95.937014 126.336997) (xy 95.816678 126.3735) (xy 95.793753 126.380454) (xy 95.661723 126.451026) (xy 95.625918 126.480411) + (xy 95.545999 126.545999) (xy 95.5222 126.574998) (xy 95.131609 126.96559) (xy 91.915211 126.96559) (xy 91.906978 126.964779) + (xy 91.819266 126.812857) (xy 91.746407 126.711183) (xy 91.655113 126.625676) (xy 91.548891 126.559624) (xy 91.431824 126.515563) + (xy 91.308411 126.495187) (xy 91.183394 126.49928) (xy 91.061577 126.527683) (xy 90.947643 126.579307) (xy 89.215593 127.579307) + (xy 89.113919 127.652165) (xy 89.028412 127.743459) (xy 88.96236 127.849681) (xy 88.918299 127.966748) (xy 88.897923 128.090161) + (xy 88.902016 128.215178) (xy 88.930419 128.336995) (xy 88.982042 128.450929) (xy 90.132042 130.442787) (xy 90.204901 130.544461) + (xy 90.296195 130.629968) (xy 90.402417 130.69602) (xy 90.519484 130.740081) (xy 90.553188 130.745646) (xy 90.552342 130.747688) + (xy 90.470295 131.160165) (xy 90.470295 131.580723) (xy 90.488699 131.673246) (xy 90.417835 131.687342) (xy 90.029289 131.848283) + (xy 89.679608 132.081932) (xy 89.382228 132.379312) (xy 89.148579 132.728993) (xy 89.047535 132.972934) (xy 89.012967 132.889479) + (xy 88.921587 132.752719) (xy 88.805281 132.636413) (xy 88.668521 132.545033) (xy 88.51656 132.482089) (xy 88.35524 132.45) + (xy 88.19076 132.45) (xy 88.02944 132.482089) (xy 87.877479 132.545033) (xy 87.740719 132.636413) (xy 87.624413 132.752719) + (xy 87.533033 132.889479) (xy 87.470089 133.04144) (xy 87.438 133.20276) (xy 87.438 133.36724) (xy 87.470089 133.52856) + (xy 87.513001 133.632158) (xy 87.513 134.235677) (xy 87.509324 134.273) (xy 87.513 134.310322) (xy 87.513 134.310332) + (xy 87.523997 134.421985) (xy 87.563309 134.551582) (xy 87.567454 134.565246) (xy 87.638026 134.697276) (xy 87.658746 134.722523) + (xy 87.732999 134.813001) (xy 87.762003 134.836804) (xy 90.240001 137.314804) (xy 90.24 138.222793) (xy 90.236324 138.260116) + (xy 90.24 138.297438) (xy 90.24 138.297448) (xy 90.250997 138.409101) (xy 90.293795 138.550188) (xy 90.294454 138.552362) + (xy 90.365026 138.684392) (xy 90.377908 138.700088) (xy 90.459999 138.800117) (xy 90.489003 138.82392) (xy 93.07243 141.407348) + (xy 93.096228 141.436346) (xy 93.211953 141.531319) (xy 93.343982 141.601891) (xy 93.487243 141.645348) (xy 93.598896 141.656345) + (xy 93.598906 141.656345) (xy 93.636229 141.660021) (xy 93.67327 141.656373) (xy 94.282338 142.71131) (xy 94.355197 142.812984) + (xy 94.446491 142.898491) (xy 94.552713 142.964543) (xy 94.66978 143.008604) (xy 94.793193 143.02898) (xy 94.91821 143.024887) + (xy 95.040027 142.996484) (xy 95.153961 142.94486) (xy 96.886011 141.94486) (xy 96.987685 141.872002) (xy 97.073192 141.780708) + (xy 97.139244 141.674486) (xy 97.183305 141.557419) (xy 97.203681 141.434006) (xy 97.199588 141.308989) (xy 97.171185 141.187172) + (xy 97.119562 141.073238) (xy 96.560294 140.104557) (xy 96.625574 140.104557) (xy 97.038051 140.02251) (xy 97.426597 139.861569) + (xy 97.776278 139.62792) (xy 98.020157 139.384041) (xy 97.947033 139.493479) (xy 97.884089 139.64544) (xy 97.852 139.80676) + (xy 97.852 139.97124) (xy 97.884089 140.13256) (xy 97.947033 140.284521) (xy 98.038413 140.421281) (xy 98.154719 140.537587) + (xy 98.291479 140.628967) (xy 98.44344 140.691911) (xy 98.60476 140.724) (xy 98.76924 140.724) (xy 98.93056 140.691911) + (xy 99.029533 140.650915) (xy 99.047411 140.652676) (xy 99.084733 140.649) (xy 99.084744 140.649) (xy 99.196397 140.638003) + (xy 99.339658 140.594546) (xy 99.471687 140.523974) (xy 99.587412 140.429001) (xy 99.611215 140.399997) (xy 101.511003 138.50021) + (xy 101.540001 138.476412) (xy 101.634974 138.360687) (xy 101.705546 138.228658) (xy 101.749003 138.085397) (xy 101.76 137.973744) + (xy 101.76 137.973734) (xy 101.763676 137.936411) (xy 101.76 137.899088) (xy 101.76 136.037333) (xy 101.763677 136) + (xy 101.751395 135.875295) (xy 101.749003 135.851014) (xy 101.705546 135.707753) (xy 101.634974 135.575724) (xy 101.540001 135.459999) + (xy 101.496472 135.424276) (xy 101.424276 135.365026) (xy 101.292247 135.294454) (xy 101.148986 135.250997) (xy 101.037333 135.24) + (xy 101 135.236323) (xy 100.962667 135.24) (xy 98.667164 135.24) (xy 98.795576 135.111588) (xy 99.089417 134.671825) + (xy 99.291817 134.183186) (xy 99.395 133.664449) (xy 99.395 133.135551) (xy 99.372733 133.023608) (xy 99.736975 133.654493) + (xy 99.751434 133.686405) (xy 99.771841 133.714883) (xy 99.771846 133.714892) (xy 99.832896 133.800088) (xy 99.934974 133.895694) + (xy 100.053741 133.969548) (xy 100.184635 134.018813) (xy 100.322625 134.041595) (xy 100.322626 134.041595) (xy 100.462407 134.037019) + (xy 100.598612 134.005261) (xy 100.694081 133.962004) (xy 100.694082 133.962004) (xy 100.726003 133.94754) (xy 100.754489 133.927127) + (xy 100.971803 133.801661) (xy 100.995929 133.843448) (xy 101.133409 133.764074) (xy 101.075303 133.980928) (xy 101.329768 134.427817) + (xy 101.402626 134.529492) (xy 101.493921 134.614998) (xy 101.600143 134.681051) (xy 101.717209 134.725111) (xy 101.840622 134.745487) + (xy 101.965639 134.741395) (xy 102.087456 134.712991) (xy 102.20139 134.661368) (xy 102.3854 134.551582) (xy 102.443507 134.334726) + (xy 101.868882 133.339446) (xy 101.851561 133.349446) (xy 101.827436 133.307661) (xy 102.082048 133.160661) (xy 102.106173 133.202446) + (xy 102.088852 133.212446) (xy 102.663477 134.207726) (xy 102.880334 134.265832) (xy 103.067416 134.161368) (xy 103.16909 134.088509) + (xy 103.254597 133.997215) (xy 103.320649 133.890993) (xy 103.329993 133.866166) (xy 103.356167 133.870487) (xy 103.481184 133.866394) + (xy 103.603 133.837991) (xy 103.716935 133.786368) (xy 103.802257 133.737107) (xy 104.363135 134.297986) (xy 104.392567 134.369041) + (xy 104.483947 134.505801) (xy 104.600253 134.622107) (xy 104.737013 134.713487) (xy 104.888974 134.776431) (xy 105.050294 134.80852) + (xy 105.214774 134.80852) (xy 105.376094 134.776431) (xy 105.528055 134.713487) (xy 105.664815 134.622107) (xy 105.781121 134.505801) + (xy 105.872501 134.369041) (xy 105.935445 134.21708) (xy 105.967534 134.05576) (xy 105.967534 133.89128) (xy 105.935445 133.72996) + (xy 105.872501 133.577999) (xy 105.781121 133.441239) (xy 105.664815 133.324933) (xy 105.528055 133.233553) (xy 105.391915 133.177162) + (xy 104.897597 132.682845) (xy 104.896538 132.650496) (xy 104.868135 132.528679) (xy 104.816511 132.414745) (xy 104.455887 131.790125) + (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) (xy 104.651604 131.677128) (xy 104.7368 131.616078) + (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) (xy 104.978308 131.126349) (xy 104.973731 130.986567) + (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.911452 130.783002) (xy 104.884253 130.722971) (xy 104.863839 130.694483) + (xy 103.694735 128.669537) (xy 103.82105 128.795852) (xy 103.855013 128.846681) (xy 103.971319 128.962987) (xy 104.108079 129.054367) + (xy 104.26004 129.117311) (xy 104.42136 129.1494) (xy 104.58584 129.1494) (xy 104.74716 129.117311) (xy 104.899121 129.054367) + (xy 105.035881 128.962987) (xy 105.152187 128.846681) (xy 105.243567 128.709921) (xy 105.306511 128.55796) (xy 105.30801 128.550422) + (xy 105.30801 129.730687) (xy 105.304334 129.76801) (xy 105.30801 129.805332) (xy 105.30801 129.805342) (xy 105.319007 129.916995) + (xy 105.354071 130.032587) (xy 105.362464 130.060256) (xy 105.433036 130.192286) (xy 105.462346 130.228) (xy 105.528009 130.308011) + (xy 105.557013 130.331814) (xy 107.517122 132.291924) (xy 107.560033 132.395521) (xy 107.651413 132.532281) (xy 107.767719 132.648587) + (xy 107.904479 132.739967) (xy 108.05644 132.802911) (xy 108.21776 132.835) (xy 108.38224 132.835) (xy 108.54356 132.802911) + (xy 108.695521 132.739967) (xy 108.832281 132.648587) (xy 108.948587 132.532281) (xy 109.039967 132.395521) (xy 109.102911 132.24356) + (xy 109.135 132.08224) (xy 109.135 131.91776) (xy 109.102911 131.75644) (xy 109.039967 131.604479) (xy 108.948587 131.467719) + (xy 108.832281 131.351413) (xy 108.695521 131.260033) (xy 108.591924 131.217122) (xy 106.82801 129.453209) (xy 106.82801 126.698472) + (xy 106.870921 126.594875) (xy 106.90301 126.433555) (xy 106.90301 126.269075) (xy 106.870921 126.107755) (xy 106.847881 126.052131) + (xy 106.93575 126.14) (xy 107.65 126.143072) (xy 107.714999 126.13667) (xy 107.714998 128.599949) (xy 107.711322 128.637272) + (xy 107.714998 128.674594) (xy 107.714998 128.674604) (xy 107.725995 128.786257) (xy 107.766155 128.918649) (xy 107.769452 128.929518) + (xy 107.840024 129.061548) (xy 107.879869 129.110098) (xy 107.934997 129.177273) (xy 107.964001 129.201076) (xy 110.137619 131.374695) + (xy 109.971493 131.419208) (xy 109.854426 131.463269) (xy 109.748204 131.529321) (xy 109.65691 131.614828) (xy 109.584051 131.716502) + (xy 109.532428 131.830436) (xy 109.504025 131.952253) (xy 109.499932 132.07727) (xy 109.520308 132.200683) (xy 110.037946 134.132535) + (xy 110.082007 134.249602) (xy 110.148059 134.355824) (xy 110.233566 134.447118) (xy 110.33524 134.519977) (xy 110.449174 134.5716) + (xy 110.570991 134.600003) (xy 110.696008 134.604096) (xy 110.819421 134.58372) (xy 111.996083 134.268434) (xy 114.027956 136.300308) + (xy 114.051754 136.329306) (xy 114.080752 136.353104) (xy 114.167478 136.424279) (xy 114.234305 136.459999) (xy 114.299508 136.494851) + (xy 114.442769 136.538308) (xy 114.554422 136.549305) (xy 114.554432 136.549305) (xy 114.591755 136.552981) (xy 114.629078 136.549305) + (xy 121.923373 136.549305) (xy 121.960695 136.552981) (xy 121.998017 136.549305) (xy 121.998028 136.549305) (xy 122.109681 136.538308) + (xy 122.252942 136.494851) (xy 122.384971 136.424279) (xy 122.500696 136.329306) (xy 122.524498 136.300303) (xy 123.041923 135.782878) + (xy 123.145521 135.739967) (xy 123.282281 135.648587) (xy 123.398587 135.532281) (xy 123.489967 135.395521) (xy 123.552911 135.24356) + (xy 123.585 135.08224) (xy 123.585 134.91776) (xy 123.552911 134.75644) (xy 123.489967 134.604479) (xy 123.398587 134.467719) + (xy 123.282281 134.351413) (xy 123.145521 134.260033) (xy 122.99356 134.197089) (xy 122.865488 134.171613) (xy 122.928117 134.108985) + (xy 122.967719 134.148587) (xy 123.104479 134.239967) (xy 123.25644 134.302911) (xy 123.41776 134.335) (xy 123.58224 134.335) + (xy 123.74356 134.302911) (xy 123.895521 134.239967) (xy 124.032281 134.148587) (xy 124.148587 134.032281) (xy 124.239967 133.895521) + (xy 124.302911 133.74356) (xy 124.332984 133.592374) (xy 125.96571 133.154886) (xy 126.082777 133.110825) (xy 126.188999 133.044773) + (xy 126.280293 132.959266) (xy 126.353152 132.857592) (xy 126.404775 132.743658) (xy 126.433178 132.621841) (xy 126.437271 132.496824) + (xy 126.416895 132.373411) (xy 126.118018 131.257987) (xy 126.711003 130.665002) (xy 126.740001 130.641204) (xy 126.834974 130.525479) + (xy 126.905546 130.39345) (xy 126.949003 130.250189) (xy 126.96 130.138536) (xy 126.96 130.138527) (xy 126.963676 130.101204) + (xy 126.96 130.063881) (xy 126.96 125.313072) (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) + (xy 128.554494 125.205537) (xy 128.651185 125.126185) (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) + (xy 128.91776 125.035) (xy 129.08224 125.035) (xy 129.24356 125.002911) (xy 129.347157 124.96) (xy 129.560199 124.96) + (xy 129.573701 124.973502) (xy 130.711928 126.11173) (xy 130.711928 127.28) (xy 130.724188 127.404482) (xy 130.760498 127.52418) + (xy 130.819463 127.634494) (xy 130.898815 127.731185) (xy 130.995506 127.810537) (xy 131.10582 127.869502) (xy 131.225518 127.905812) + (xy 131.35 127.918072) (xy 131.845674 127.918072) (xy 131.865026 127.954276) (xy 131.902142 127.999502) (xy 131.959999 128.070001) + (xy 131.989003 128.093804) (xy 134.961398 131.0662) (xy 134.437803 131.0662) (xy 133.407279 130.035677) (xy 133.364367 129.932079) + (xy 133.272987 129.795319) (xy 133.156681 129.679013) (xy 133.019921 129.587633) (xy 132.86796 129.524689) (xy 132.70664 129.4926) + (xy 132.54216 129.4926) (xy 132.38084 129.524689) (xy 132.228879 129.587633) (xy 132.092119 129.679013) (xy 131.975813 129.795319) + (xy 131.884433 129.932079) (xy 131.821489 130.08404) (xy 131.7894 130.24536) (xy 131.7894 130.40984) (xy 131.821489 130.57116) + (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) (xy 132.228879 131.067567) (xy 132.332477 131.110479) + (xy 133.559205 132.337208) (xy 133.582999 132.366201) (xy 133.611992 132.389995) (xy 133.611996 132.389999) (xy 133.674055 132.440929) + (xy 133.698724 132.461174) (xy 133.830753 132.531746) (xy 133.974014 132.575203) (xy 134.085667 132.5862) (xy 134.085676 132.5862) + (xy 134.122999 132.589876) (xy 134.160322 132.5862) (xy 142.970643 132.5862) (xy 143.07424 132.629111) (xy 143.23556 132.6612) + (xy 143.40004 132.6612) (xy 143.56136 132.629111) (xy 143.713321 132.566167) (xy 143.850081 132.474787) (xy 143.966387 132.358481) + (xy 144.057767 132.221721) (xy 144.120711 132.06976) (xy 144.1528 131.90844) (xy 144.1528 131.74396) (xy 144.120711 131.58264) + (xy 144.073474 131.4686) (xy 144.524078 131.4686) (xy 144.5614 131.472276) (xy 144.598722 131.4686) (xy 144.598733 131.4686) + (xy 144.710386 131.457603) (xy 144.853647 131.414146) (xy 144.985676 131.343574) (xy 145.101401 131.248601) (xy 145.125203 131.219598) + (xy 145.711002 130.6338) (xy 145.740001 130.610001) (xy 145.834974 130.494276) (xy 145.854326 130.458072) (xy 146.35 130.458072) + (xy 146.474482 130.445812) (xy 146.59418 130.409502) (xy 146.704494 130.350537) (xy 146.801185 130.271185) (xy 146.880537 130.174494) + (xy 146.912872 130.114) (xy 147.441043 130.114) (xy 147.54464 130.156911) (xy 147.70596 130.189) (xy 147.87044 130.189) + (xy 148.03176 130.156911) (xy 148.183721 130.093967) (xy 148.320481 130.002587) (xy 148.436787 129.886281) (xy 148.528167 129.749521) + (xy 148.591111 129.59756) (xy 148.6232 129.43624) (xy 148.6232 129.27176) (xy 148.591111 129.11044) (xy 148.528167 128.958479) + (xy 148.436787 128.821719) (xy 148.320481 128.705413) (xy 148.183721 128.614033) (xy 148.03176 128.551089) (xy 147.87044 128.519) + (xy 147.70596 128.519) (xy 147.54464 128.551089) (xy 147.441043 128.594) (xy 146.988072 128.594) (xy 146.988072 127.82) + (xy 146.975812 127.695518) (xy 146.939502 127.57582) (xy 146.880537 127.465506) (xy 146.801185 127.368815) (xy 146.704494 127.289463) + (xy 146.59418 127.230498) (xy 146.474482 127.194188) (xy 146.35 127.181928) (xy 145.230748 127.181928) (xy 145.362953 126.862756) + (xy 145.445 126.450279) (xy 145.445 126.029721) (xy 145.362953 125.617244) (xy 145.202012 125.228698) (xy 145.164985 125.173283) + (xy 145.330779 125.104609) (xy 145.590379 124.93115) (xy 145.81115 124.710379) (xy 145.984609 124.450779) (xy 146.104089 124.162327) + (xy 146.165 123.856109) (xy 146.165 123.543891) (xy 146.104089 123.237673) (xy 145.984609 122.949221) (xy 145.81115 122.689621) + (xy 145.590379 122.46885) (xy 145.330779 122.295391) (xy 145.042327 122.175911) (xy 144.736109 122.115) (xy 144.423891 122.115) + (xy 144.117673 122.175911) (xy 144.023303 122.215) (xy 143.85374 122.215) (xy 143.566842 122.272068) (xy 143.296589 122.38401) + (xy 143.053368 122.546525) (xy 142.846525 122.753368) (xy 142.68401 122.996589) (xy 142.572068 123.266842) (xy 142.515 123.55374) + (xy 142.515 123.84626) (xy 142.572068 124.133158) (xy 142.607988 124.219876) (xy 142.298698 124.347988) (xy 142.076252 124.496622) + (xy 142.081817 124.483186) (xy 142.185 123.964449) (xy 142.185 123.435551) (xy 142.081817 122.916814) (xy 141.879417 122.428175) + (xy 141.585576 121.988412) (xy 141.261364 121.6642) (xy 145.299401 121.6642) (xy 153.500204 129.865004) (xy 153.524002 129.894002) + (xy 153.639727 129.988975) (xy 153.771756 130.059547) (xy 153.915017 130.103004) (xy 154.02667 130.114001) (xy 154.026679 130.114001) + (xy 154.064002 130.117677) (xy 154.101325 130.114001) (xy 169.757177 130.114001) (xy 169.794499 130.117677) (xy 169.831821 130.114001) + (xy 169.831832 130.114001) (xy 169.943485 130.103004) (xy 170.086746 130.059547) (xy 170.218775 129.988975) (xy 170.3345 129.894002) + (xy 170.358302 129.864999) (xy 170.6245 129.598801) (xy 173.159701 132.134003) (xy 173.183499 132.163001) (xy 173.212497 132.186799) + (xy 173.299223 132.257974) (xy 173.431253 132.328546) (xy 173.574514 132.372003) (xy 173.686167 132.383) (xy 173.686176 132.383) + (xy 173.723499 132.386676) (xy 173.760822 132.383) (xy 177.717843 132.383) (xy 177.82144 132.425911) (xy 177.98276 132.458) + (xy 178.14724 132.458) (xy 178.30856 132.425911) (xy 178.460521 132.362967) (xy 178.597281 132.271587) (xy 178.713587 132.155281) + (xy 178.804967 132.018521) (xy 178.867911 131.86656) (xy 178.891494 131.748) (xy 181.194678 131.748) (xy 181.232 131.751676) + (xy 181.269322 131.748) (xy 181.269333 131.748) (xy 181.380986 131.737003) (xy 181.524247 131.693546) (xy 181.656276 131.622974) + (xy 181.772001 131.528001) (xy 181.795804 131.498997) (xy 182.736729 130.558072) (xy 184.45 130.558072) (xy 184.574482 130.545812) + (xy 184.69418 130.509502) (xy 184.804494 130.450537) (xy 184.901185 130.371185) (xy 184.980537 130.274494) (xy 185.039502 130.16418) + (xy 185.075812 130.044482) (xy 185.088072 129.92) (xy 185.088072 128.343229) (xy 194.671302 118.76) (xy 202.891678 118.76) + (xy 202.929 118.763676) (xy 202.966322 118.76) (xy 202.966333 118.76) (xy 203.077986 118.749003) (xy 203.221247 118.705546) + (xy 203.353276 118.634974) (xy 203.469001 118.540001) (xy 203.492803 118.510998) (xy 204.743813 117.25999) (xy 209.652843 117.25999) + (xy 209.75644 117.302901) (xy 209.91776 117.33499) (xy 210.08224 117.33499) (xy 210.24356 117.302901) (xy 210.395521 117.239957) + (xy 210.402955 117.23499) (xy 221.07053 117.23499) (xy 221.107852 117.238666) (xy 221.145174 117.23499) (xy 221.145185 117.23499) + (xy 221.256838 117.223993) (xy 221.400099 117.180536) (xy 221.532128 117.109964) (xy 221.647853 117.014991) (xy 221.671656 116.985987) + (xy 221.960997 116.696646) (xy 221.990001 116.672843) (xy 222.084974 116.557118) (xy 222.155546 116.425089) (xy 222.199003 116.281828) + (xy 222.201343 116.258072) (xy 222.6 116.258072) (xy 222.724482 116.245812) (xy 222.84418 116.209502) (xy 222.954494 116.150537) + (xy 223.051185 116.071185) (xy 223.130537 115.974494) (xy 223.189502 115.86418) (xy 223.225812 115.744482) (xy 223.238072 115.62) + (xy 223.238072 114.05673) (xy 223.361004 113.933798) (xy 223.390001 113.910001) (xy 223.416332 113.877917) (xy 223.484974 113.794277) + (xy 223.555546 113.662247) (xy 223.566009 113.627754) (xy 223.599003 113.518986) (xy 223.61 113.407333) (xy 223.61 113.407323) + (xy 223.613676 113.37) (xy 223.61 113.332677) (xy 223.61 107.387325) (xy 223.613676 107.35) (xy 223.61 107.312675) + (xy 223.61 107.312667) (xy 223.599003 107.201014) (xy 223.555546 107.057753) (xy 223.484974 106.925724) (xy 223.390001 106.809999) + (xy 223.361003 106.786201) (xy 222.035009 105.460208) (xy 222.035009 101.275922) (xy 222.038685 101.238599) (xy 222.035009 101.201276) + (xy 222.035009 101.201266) (xy 222.024012 101.089613) (xy 221.980555 100.946352) (xy 221.909983 100.814323) (xy 221.81501 100.698598) + (xy 221.786011 100.674799) (xy 221.51 100.398789) (xy 221.51 98.097157) (xy 221.552911 97.99356) (xy 221.585 97.83224) + (xy 221.585 97.66776) (xy 221.552911 97.50644) (xy 221.51 97.402843) (xy 221.51 97.258072) (xy 222.55 97.258072) + (xy 222.674482 97.245812) (xy 222.79418 97.209502) (xy 222.904494 97.150537) (xy 223.001185 97.071185) (xy 223.080537 96.974494) + (xy 223.139502 96.86418) (xy 223.175812 96.744482) (xy 223.188072 96.62) (xy 223.188072 94.62) (xy 223.175812 94.495518) + (xy 223.139502 94.37582) (xy 223.080537 94.265506) (xy 223.001185 94.168815) (xy 222.904494 94.089463) (xy 222.815001 94.041627) + (xy 222.815001 80.017314) (xy 222.818677 79.979991) (xy 222.815001 79.942668) (xy 222.815001 79.942658) (xy 222.804004 79.831005) + (xy 222.760547 79.687744) (xy 222.689975 79.555715) (xy 222.595002 79.43999) (xy 222.566004 79.416192) (xy 221.332879 78.183068) + (xy 221.31 78.127833) (xy 221.31 78.058072) (xy 222.55 78.058072) (xy 222.674482 78.045812) (xy 222.79418 78.009502) + (xy 222.904494 77.950537) (xy 223.001185 77.871185) (xy 223.080537 77.774494) (xy 223.139502 77.66418) (xy 223.175812 77.544482) + (xy 223.188072 77.42) (xy 223.188072 75.42) (xy 223.175812 75.295518) (xy 223.139502 75.17582) (xy 223.080537 75.065506) + (xy 223.001185 74.968815) (xy 222.904494 74.889463) (xy 222.79418 74.830498) (xy 222.674482 74.794188) (xy 222.55 74.781928) + (xy 222.16 74.781928) (xy 222.16 72.881803) (xy 222.566005 72.475799) (xy 222.595002 72.452002) (xy 222.689975 72.336277) + (xy 222.760547 72.204248) (xy 222.804004 72.060987) (xy 222.815001 71.949334) (xy 222.815001 71.949325) (xy 222.818677 71.912002) + (xy 222.815001 71.874679) (xy 222.815001 61.342334) (xy 222.818678 61.305001) (xy 222.804004 61.156015) (xy 222.760547 61.012754) + (xy 222.689975 60.880725) (xy 222.648794 60.830546) (xy 222.595002 60.765) (xy 222.566004 60.741202) (xy 221.282879 59.458078) + (xy 221.26 59.402843) (xy 221.26 59.158072) (xy 222.65 59.158072) (xy 222.774482 59.145812) (xy 222.89418 59.109502) + (xy 223.004494 59.050537) (xy 223.101185 58.971185) (xy 223.180537 58.874494) (xy 223.239502 58.76418) (xy 223.275812 58.644482) + (xy 223.288072 58.52) (xy 223.288072 56.52) (xy 223.275812 56.395518) (xy 223.239502 56.27582) (xy 223.180537 56.165506) + (xy 223.101185 56.068815) (xy 223.004494 55.989463) (xy 222.89418 55.930498) (xy 222.774482 55.894188) (xy 222.65 55.881928) + (xy 221.530748 55.881928) (xy 221.662953 55.562756) (xy 221.745 55.150279) (xy 221.745 54.729721) (xy 221.662953 54.317244) + (xy 221.502012 53.928698) (xy 221.464985 53.873283) (xy 221.630779 53.804609) (xy 221.890379 53.63115) (xy 222.11115 53.410379) + (xy 222.284609 53.150779) (xy 222.404089 52.862327) (xy 222.465 52.556109) (xy 222.465 52.243891) (xy 222.404089 51.937673) + (xy 222.284609 51.649221) (xy 222.11115 51.389621) (xy 221.890379 51.16885) (xy 221.630779 50.995391) (xy 221.342327 50.875911) + (xy 221.036109 50.815) (xy 220.723891 50.815) (xy 220.417673 50.875911) (xy 220.323303 50.915) (xy 220.15374 50.915) + (xy 219.866842 50.972068) (xy 219.596589 51.08401) (xy 219.353368 51.246525) (xy 219.146525 51.453368) (xy 218.98401 51.696589) + (xy 218.872068 51.966842) (xy 218.815 52.25374) (xy 218.815 52.54626) (xy 218.872068 52.833158) (xy 218.907988 52.919876) + (xy 218.598698 53.047988) (xy 218.376252 53.196622) (xy 218.381817 53.183186) (xy 218.485 52.664449) (xy 218.485 52.135551) + (xy 218.381817 51.616814) (xy 218.179417 51.128175) (xy 217.885576 50.688412) (xy 217.511588 50.314424) (xy 217.071825 50.020583) + (xy 216.687522 49.8614) (xy 217.415123 49.8614) (xy 217.45 49.864835) (xy 217.484877 49.8614) (xy 217.589184 49.851127) + (xy 217.72302 49.810528) (xy 217.846363 49.7446) (xy 217.954475 49.655875) (xy 218.0432 49.547763) (xy 218.109128 49.42442) + (xy 218.149727 49.290584) (xy 218.163435 49.1514) (xy 218.16 49.116523) (xy 218.16 47.628) (xy 218.327 47.628) + (xy 218.327 47.648) (xy 218.347 47.648) (xy 218.347 47.902) (xy 218.327 47.902) (xy 218.327 48.75125) + (xy 218.48575 48.91) (xy 219 48.913072) (xy 219.124482 48.900812) (xy 219.24418 48.864502) (xy 219.354494 48.805537) + (xy 219.451185 48.726185) (xy 219.530537 48.629494) (xy 219.589502 48.51918) (xy 219.625812 48.399482) (xy 219.638072 48.275) + (xy 219.635 48.06075) (xy 219.476252 47.902002) (xy 219.635 47.902002) (xy 219.635 47.804614) (xy 219.64356 47.802911) + (xy 219.795521 47.739967) (xy 219.932281 47.648587) (xy 220.048587 47.532281) (xy 220.139967 47.395521) (xy 220.202911 47.24356) + (xy 220.235 47.08224) (xy 220.235 46.91776) (xy 220.202911 46.75644) (xy 220.139967 46.604479) (xy 220.048587 46.467719) + (xy 219.932281 46.351413) (xy 219.795521 46.260033) (xy 219.691923 46.217122) (xy 219.638072 46.16327) (xy 219.638072 45.525) + (xy 219.625812 45.400518) (xy 219.589502 45.28082) (xy 219.530537 45.170506) (xy 219.451185 45.073815) (xy 219.354494 44.994463) + (xy 219.24418 44.935498) (xy 219.16 44.909962) (xy 219.16 44.747157) (xy 219.202911 44.64356) (xy 219.235 44.48224) + (xy 219.235 44.31776) (xy 219.202911 44.15644) (xy 219.139967 44.004479) (xy 219.048587 43.867719) (xy 218.932281 43.751413) + (xy 218.795521 43.660033) (xy 218.64356 43.597089) (xy 218.48224 43.565) (xy 218.31776 43.565) (xy 218.15644 43.597089) + (xy 218.004479 43.660033) (xy 217.867719 43.751413) (xy 217.751413 43.867719) (xy 217.67743 43.978442) (xy 217.589184 43.951673) + (xy 217.484877 43.9414) (xy 217.45 43.937965) (xy 217.415123 43.9414) (xy 213.984877 43.9414) (xy 213.95 43.937965) + (xy 213.915123 43.9414) (xy 213.810816 43.951673) (xy 213.67698 43.992272) (xy 213.553637 44.0582) (xy 213.445525 44.146925) + (xy 213.3568 44.255037) (xy 213.290872 44.37838) (xy 213.250273 44.512216) (xy 213.236565 44.6514) (xy 213.240001 44.686287) + (xy 213.240001 44.886928) (xy 212.6 44.886928) (xy 212.475518 44.899188) (xy 212.35582 44.935498) (xy 212.245506 44.994463) + (xy 212.148815 45.073815) (xy 212.094499 45.14) (xy 211.818466 45.14) (xy 211.788641 45.137063) (xy 210.430332 43.778754) + (xy 210.402617 43.744983) (xy 210.267859 43.634389) (xy 210.114113 43.552211) (xy 209.94729 43.501605) (xy 209.817277 43.4888) + (xy 209.817269 43.4888) (xy 209.7738 43.484519) (xy 209.730331 43.4888) (xy 206.365023 43.4888) (xy 206.239249 43.385579) + (xy 206.085503 43.303401) (xy 205.91868 43.252795) (xy 205.788667 43.23999) (xy 205.788659 43.23999) (xy 205.74519 43.235709) + (xy 205.701721 43.23999) (xy 194.668479 43.23999) (xy 194.62501 43.235709) (xy 194.581541 43.23999) (xy 194.581533 43.23999) + (xy 194.45152 43.252795) (xy 194.284697 43.303401) (xy 194.130951 43.385579) (xy 193.996193 43.496173) (xy 193.968476 43.529946) + (xy 193.704956 43.793466) (xy 193.671183 43.821183) (xy 193.645482 43.8525) (xy 193.379079 43.8525) (xy 188.334046 38.807468) + (xy 188.181533 38.654955) (xy 188.153816 38.621182) (xy 188.019058 38.510588) (xy 187.865312 38.42841) (xy 187.698489 38.377804) + (xy 187.568476 38.364999) (xy 187.568468 38.364999) (xy 187.524999 38.360718) (xy 187.48153 38.364999) (xy 175.75099 38.364999) + (xy 175.707524 38.360718) (xy 175.664058 38.364999) (xy 175.664048 38.364999) (xy 175.534035 38.377804) (xy 175.367212 38.42841) + (xy 175.213466 38.510588) (xy 175.078708 38.621182) (xy 175.050991 38.654955) (xy 174.952736 38.75321) (xy 169.314789 38.75321) + (xy 168.345046 37.783468) (xy 168.244059 37.70059) (xy 168.090313 37.618412) (xy 168.075496 37.613917) (xy 166.482013 36.020435) + (xy 166.454296 35.986662) (xy 166.319538 35.876068) (xy 166.165792 35.79389) (xy 165.998969 35.743284) (xy 165.868956 35.730479) + (xy 165.868948 35.730479) (xy 165.825479 35.726198) (xy 165.78201 35.730479) (xy 156.517987 35.730479) (xy 156.47452 35.726198) + (xy 156.431054 35.730479) (xy 156.431044 35.730479) (xy 156.301031 35.743284) (xy 156.134208 35.79389) (xy 155.980462 35.876068) + (xy 155.845704 35.986662) (xy 155.817987 36.020435) (xy 155.404952 36.43347) (xy 155.371184 36.461183) (xy 155.260589 36.595941) + (xy 155.178411 36.749687) (xy 155.127805 36.91651) (xy 155.115 37.046523) (xy 155.115 37.046531) (xy 155.110719 37.09) + (xy 155.115 37.133469) (xy 155.115 37.557317) (xy 155.045506 37.594463) (xy 154.948815 37.673815) (xy 154.869463 37.770506) + (xy 154.818954 37.865) (xy 153.825476 37.865) (xy 153.782 37.860718) (xy 153.738523 37.865) (xy 137.368479 37.865) + (xy 137.32501 37.860719) (xy 137.281541 37.865) (xy 137.281533 37.865) (xy 137.15152 37.877805) (xy 136.984697 37.928411) + (xy 136.857903 37.996183) (xy 136.830951 38.010589) (xy 136.729963 38.093468) (xy 136.729961 38.09347) (xy 136.696193 38.121183) + (xy 136.66848 38.154951) (xy 134.904958 39.918474) (xy 134.904953 39.918478) (xy 134.904951 39.91848) (xy 134.871183 39.946193) + (xy 134.84347 39.979961) (xy 134.308432 40.515) (xy 127.643465 40.515) (xy 127.599999 40.510719) (xy 127.556533 40.515) + (xy 118.643465 40.515) (xy 118.599999 40.510719) (xy 118.556533 40.515) (xy 118.556523 40.515) (xy 118.42651 40.527805) + (xy 118.259687 40.578411) (xy 118.105941 40.660589) (xy 118.097828 40.667247) (xy 118.004953 40.743468) (xy 118.004951 40.74347) + (xy 117.971183 40.771183) (xy 117.94347 40.804951) (xy 116.833423 41.914999) (xy 116.131464 41.914999) (xy 116.087998 41.910718) + (xy 116.044532 41.914999) (xy 116.044522 41.914999) (xy 115.914509 41.927804) (xy 115.747686 41.97841) (xy 115.59394 42.060588) + (xy 115.459182 42.171182) (xy 115.431465 42.204955) (xy 115.154955 42.481465) (xy 115.121182 42.509182) (xy 115.010588 42.643941) + (xy 114.92841 42.797687) (xy 114.896094 42.904217) (xy 114.877804 42.964509) (xy 114.876211 42.980685) (xy 114.864999 43.094523) + (xy 114.864999 43.09453) (xy 114.860718 43.137999) (xy 114.864999 43.181469) (xy 114.864999 43.615) (xy 113.793465 43.615) + (xy 113.749999 43.610719) (xy 113.706533 43.615) (xy 113.706523 43.615) (xy 113.57651 43.627805) (xy 113.409687 43.678411) + (xy 113.255941 43.760589) (xy 113.244474 43.77) (xy 113.154953 43.843468) (xy 113.154951 43.84347) (xy 113.121183 43.871183) + (xy 113.09347 43.904951) (xy 111.129958 45.868464) (xy 111.129953 45.868468) (xy 110.015389 46.983032) (xy 109.986451 46.902722) + (xy 109.924471 46.786765) (xy 109.68438 46.719785) (xy 108.89842 47.505745) (xy 108.912563 47.519888) (xy 108.732958 47.699493) + (xy 108.718815 47.68535) (xy 108.704673 47.699493) (xy 108.525068 47.519888) (xy 108.53921 47.505745) (xy 108.525068 47.491603) + (xy 108.704673 47.311998) (xy 108.718815 47.32614) (xy 109.504775 46.54018) (xy 109.437795 46.300089) (xy 109.302055 46.23626) + (xy 109.380542 46.20375) (xy 109.60935 46.050865) (xy 109.803935 45.85628) (xy 109.95682 45.627472) (xy 110.062129 45.373235) + (xy 110.115815 45.103337) (xy 110.115815 44.828153) (xy 110.062129 44.558255) (xy 109.95682 44.304018) (xy 109.803935 44.07521) + (xy 109.60935 43.880625) (xy 109.380542 43.72774) (xy 109.3033 43.695745) (xy 109.380542 43.66375) (xy 109.60935 43.510865) + (xy 109.803935 43.31628) (xy 109.95682 43.087472) (xy 110.062129 42.833235) (xy 110.115815 42.563337) (xy 110.115815 42.288153) + (xy 110.062129 42.018255) (xy 109.95682 41.764018) (xy 109.803935 41.53521) (xy 109.60935 41.340625) (xy 109.380542 41.18774) + (xy 109.126305 41.082431) (xy 108.856407 41.028745) (xy 108.804337 41.028745) (xy 108.763314 40.82251) (xy 108.658005 40.568273) + (xy 108.50512 40.339465) (xy 108.310535 40.14488) (xy 108.081727 39.991995) (xy 107.82749 39.886686) (xy 107.557592 39.833) + (xy 107.282408 39.833) (xy 107.01251 39.886686) (xy 106.758273 39.991995) (xy 106.529465 40.14488) (xy 106.33488 40.339465) + (xy 106.181995 40.568273) (xy 106.076686 40.82251) (xy 106.071225 40.849967) (xy 105.991928 40.817121) (xy 105.89381 40.719003) + (xy 105.870007 40.689999) (xy 105.754282 40.595026) (xy 105.622253 40.524454) (xy 105.478992 40.480997) (xy 105.367339 40.47) + (xy 105.367328 40.47) (xy 105.330006 40.466324) (xy 105.292684 40.47) (xy 93.352341 40.47) (xy 93.26512 40.339465) + (xy 93.070535 40.14488) (xy 92.841727 39.991995) (xy 92.58749 39.886686) (xy 92.317592 39.833) (xy 92.042408 39.833) + (xy 91.77251 39.886686) (xy 91.518273 39.991995) (xy 91.289465 40.14488) (xy 91.09488 40.339465) (xy 90.941995 40.568273) + (xy 90.836686 40.82251) (xy 90.783 41.092408) (xy 90.783 41.367592) (xy 90.836686 41.63749) (xy 90.941995 41.891727) + (xy 91.09488 42.120535) (xy 91.289465 42.31512) (xy 91.518273 42.468005) (xy 91.595515 42.5) (xy 91.518273 42.531995) + (xy 91.289465 42.68488) (xy 91.09488 42.879465) (xy 90.941995 43.108273) (xy 90.836686 43.36251) (xy 90.783 43.632408) + (xy 90.783 43.907592) (xy 90.836686 44.17749) (xy 90.941995 44.431727) (xy 91.09488 44.660535) (xy 91.289465 44.85512) + (xy 91.518273 45.008005) (xy 91.589943 45.037692) (xy 91.576977 45.042364) (xy 91.46102 45.104344) (xy 91.39404 45.344435) + (xy 92.18 46.130395) (xy 92.96596 45.344435) (xy 92.956048 45.308907) (xy 93.29921 44.965745) (xy 93.285068 44.951603) + (xy 93.464673 44.771998) (xy 93.478815 44.78614) (xy 93.492958 44.771998) (xy 93.672563 44.951603) (xy 93.65842 44.965745) + (xy 94.44438 45.751705) (xy 94.684471 45.684725) (xy 94.801571 45.435697) (xy 94.867838 45.16861) (xy 94.875429 45.006688) + (xy 95.01776 45.035) (xy 95.18224 45.035) (xy 95.34356 45.002911) (xy 95.495521 44.939967) (xy 95.632281 44.848587) + (xy 95.748587 44.732281) (xy 95.839967 44.595521) (xy 95.867107 44.53) (xy 105.049889 44.53) (xy 105.051413 44.532281) + (xy 105.167719 44.648587) (xy 105.304479 44.739967) (xy 105.45644 44.802911) (xy 105.61776 44.835) (xy 105.78224 44.835) + (xy 105.94356 44.802911) (xy 106.095521 44.739967) (xy 106.232281 44.648587) (xy 106.348587 44.532281) (xy 106.351882 44.52735) + (xy 106.454435 44.55596) (xy 107.240395 43.77) (xy 107.226253 43.755858) (xy 107.405858 43.576253) (xy 107.42 43.590395) + (xy 107.434143 43.576253) (xy 107.613748 43.755858) (xy 107.599605 43.77) (xy 107.613748 43.784143) (xy 107.434143 43.963748) + (xy 107.42 43.949605) (xy 106.63404 44.735565) (xy 106.70102 44.975656) (xy 106.83676 45.039485) (xy 106.758273 45.071995) + (xy 106.529465 45.22488) (xy 106.33488 45.419465) (xy 106.321159 45.44) (xy 105.737322 45.44) (xy 105.699999 45.436324) + (xy 105.662676 45.44) (xy 105.662667 45.44) (xy 105.551014 45.450997) (xy 105.407753 45.494454) (xy 105.275724 45.565026) + (xy 105.159999 45.659999) (xy 105.136201 45.688997) (xy 104.079454 46.745745) (xy 94.651156 46.745745) (xy 94.563935 46.61521) + (xy 94.36935 46.420625) (xy 94.140542 46.26774) (xy 94.068872 46.238053) (xy 94.081838 46.233381) (xy 94.197795 46.171401) + (xy 94.264775 45.93131) (xy 93.478815 45.14535) (xy 92.692855 45.93131) (xy 92.702767 45.966838) (xy 92.359605 46.31) + (xy 92.373748 46.324143) (xy 92.194143 46.503748) (xy 92.18 46.489605) (xy 91.39404 47.275565) (xy 91.46102 47.515656) + (xy 91.591644 47.577079) (xy 91.576977 47.582364) (xy 91.46102 47.644344) (xy 91.39404 47.884435) (xy 92.18 48.670395) + (xy 92.194143 48.656253) (xy 92.373748 48.835858) (xy 92.359605 48.85) (xy 92.373748 48.864143) (xy 92.194143 49.043748) + (xy 92.18 49.029605) (xy 91.39404 49.815565) (xy 91.46102 50.055656) (xy 91.59676 50.119485) (xy 91.518273 50.151995) + (xy 91.289465 50.30488) (xy 91.09488 50.499465) (xy 90.941995 50.728273) (xy 90.836686 50.98251) (xy 90.783 51.252408) + (xy 90.783 51.527592) (xy 90.836686 51.79749) (xy 90.941995 52.051727) (xy 91.09488 52.280535) (xy 91.289465 52.47512) + (xy 91.518273 52.628005) (xy 91.595515 52.66) (xy 91.518273 52.691995) (xy 91.289465 52.84488) (xy 91.09488 53.039465) + (xy 90.941995 53.268273) (xy 90.836686 53.52251) (xy 90.783 53.792408) (xy 90.783 54.067592) (xy 90.836686 54.33749) + (xy 90.941995 54.591727) (xy 91.09488 54.820535) (xy 91.289465 55.01512) (xy 91.518273 55.168005) (xy 91.595515 55.2) + (xy 91.518273 55.231995) (xy 91.289465 55.38488) (xy 91.09488 55.579465) (xy 90.941995 55.808273) (xy 90.836686 56.06251) + (xy 90.783 56.332408) (xy 90.783 56.607592) (xy 90.836686 56.87749) (xy 90.941995 57.131727) (xy 91.09488 57.360535) + (xy 91.289465 57.55512) (xy 91.518273 57.708005) (xy 91.595515 57.74) (xy 91.518273 57.771995) (xy 91.289465 57.92488) + (xy 91.09488 58.119465) (xy 90.941995 58.348273) (xy 90.836686 58.60251) (xy 90.783 58.872408) (xy 90.783 59.147592) + (xy 90.836686 59.41749) (xy 90.941995 59.671727) (xy 91.09488 59.900535) (xy 91.289465 60.09512) (xy 91.518273 60.248005) + (xy 91.595515 60.28) (xy 91.518273 60.311995) (xy 91.289465 60.46488) (xy 91.09488 60.659465) (xy 90.941995 60.888273) + (xy 90.836686 61.14251) (xy 90.783 61.412408) (xy 90.783 61.687592) (xy 90.836686 61.95749) (xy 90.941995 62.211727) + (xy 91.09488 62.440535) (xy 91.289465 62.63512) (xy 91.518273 62.788005) (xy 91.595515 62.82) (xy 91.518273 62.851995) + (xy 91.289465 63.00488) (xy 91.09488 63.199465) (xy 90.941995 63.428273) (xy 90.836686 63.68251) (xy 90.783 63.952408) + (xy 90.783 64.227592) (xy 90.836686 64.49749) (xy 90.941995 64.751727) (xy 91.09488 64.980535) (xy 91.289465 65.17512) + (xy 91.518273 65.328005) (xy 91.595515 65.36) (xy 91.518273 65.391995) (xy 91.289465 65.54488) (xy 91.09488 65.739465) + (xy 90.941995 65.968273) (xy 90.836686 66.22251) (xy 90.783 66.492408) (xy 90.783 66.767592) (xy 90.836686 67.03749) + (xy 90.941995 67.291727) (xy 91.09488 67.520535) (xy 91.289465 67.71512) (xy 91.518273 67.868005) (xy 91.595515 67.9) + (xy 91.518273 67.931995) (xy 91.289465 68.08488) (xy 91.09488 68.279465) (xy 90.941995 68.508273) (xy 90.836686 68.76251) + (xy 90.783 69.032408) (xy 90.783 69.307592) (xy 90.836686 69.57749) (xy 90.941995 69.831727) (xy 91.09488 70.060535) + (xy 91.289465 70.25512) (xy 91.518273 70.408005) (xy 91.77251 70.513314) (xy 92.042408 70.567) (xy 92.094478 70.567) + (xy 92.135501 70.773235) (xy 92.24081 71.027472) (xy 92.393695 71.25628) (xy 92.58828 71.450865) (xy 92.817088 71.60375) + (xy 93.071325 71.709059) (xy 93.341223 71.762745) (xy 93.616407 71.762745) (xy 93.886305 71.709059) (xy 94.04 71.645396) + (xy 94.040001 73.544048) (xy 93.4285 73.544048) (xy 93.304018 73.556308) (xy 93.18432 73.592618) (xy 93.074006 73.651583) + (xy 92.977315 73.730935) (xy 92.897963 73.827626) (xy 92.838998 73.93794) (xy 92.802688 74.057638) (xy 92.790428 74.18212) + (xy 92.790428 74.81712) (xy 92.802688 74.941602) (xy 92.820403 75) (xy 92.802688 75.058398) (xy 92.790428 75.18288) + (xy 92.790428 75.81788) (xy 92.802688 75.942362) (xy 92.838998 76.06206) (xy 92.897963 76.172374) (xy 92.977315 76.269065) + (xy 93.074006 76.348417) (xy 93.18432 76.407382) (xy 93.24 76.424272) (xy 93.240001 80.935197) (xy 92.36401 81.811189) + (xy 92.335009 81.834989) (xy 92.311211 81.863987) (xy 92.065995 82.109203) (xy 91.991111 82.086487) (xy 91.77295 82.065) + (xy 90.974885 82.065) (xy 91.042252 82.019987) (xy 91.269987 81.792252) (xy 91.448918 81.524463) (xy 91.572168 81.226912) + (xy 91.635 80.911033) (xy 91.635 80.588967) (xy 91.572168 80.273088) (xy 91.448918 79.975537) (xy 91.269987 79.707748) + (xy 91.042252 79.480013) (xy 90.774463 79.301082) (xy 90.476912 79.177832) (xy 90.161033 79.115) (xy 89.838967 79.115) + (xy 89.523088 79.177832) (xy 89.225537 79.301082) (xy 88.959613 79.478767) (xy 88.959539 75.470069) (xy 89.044193 75.385415) + (xy 89.139956 75.649814) (xy 89.429571 75.790704) (xy 89.741108 75.872384) (xy 90.062595 75.891718) (xy 90.381675 75.847961) + (xy 90.686088 75.742795) (xy 90.860044 75.649814) (xy 90.955808 75.385413) (xy 90 74.429605) (xy 89.985858 74.443748) + (xy 89.806253 74.264143) (xy 89.820395 74.25) (xy 90.179605 74.25) (xy 91.135413 75.205808) (xy 91.399814 75.110044) + (xy 91.540704 74.820429) (xy 91.622384 74.508892) (xy 91.641718 74.187405) (xy 91.597961 73.868325) (xy 91.492795 73.563912) + (xy 91.399814 73.389956) (xy 91.135413 73.294192) (xy 90.179605 74.25) (xy 89.820395 74.25) (xy 89.806253 74.235858) + (xy 89.985858 74.056253) (xy 90 74.070395) (xy 90.955808 73.114587) (xy 90.860044 72.850186) (xy 90.570429 72.709296) + (xy 90.258892 72.627616) (xy 89.937405 72.608282) (xy 89.618325 72.652039) (xy 89.313912 72.757205) (xy 89.139956 72.850186) + (xy 89.044193 73.114585) (xy 88.959493 73.029885) (xy 88.959049 48.922017) (xy 90.77809 48.922017) (xy 90.819078 49.194133) + (xy 90.912364 49.453023) (xy 90.974344 49.56898) (xy 91.214435 49.63596) (xy 92.000395 48.85) (xy 91.214435 48.06404) + (xy 90.974344 48.13102) (xy 90.857244 48.380048) (xy 90.790977 48.647135) (xy 90.77809 48.922017) (xy 88.959049 48.922017) + (xy 88.959003 46.382017) (xy 90.77809 46.382017) (xy 90.819078 46.654133) (xy 90.912364 46.913023) (xy 90.974344 47.02898) + (xy 91.214435 47.09596) (xy 92.000395 46.31) (xy 91.214435 45.52404) (xy 90.974344 45.59102) (xy 90.857244 45.840048) + (xy 90.790977 46.107135) (xy 90.77809 46.382017) (xy 88.959003 46.382017) (xy 88.958857 38.511863) (xy 88.971894 38.382509) + (xy 88.998593 38.296493) (xy 89.041067 38.218238) (xy 89.097851 38.149414) (xy 89.16667 38.092633) (xy 89.244936 38.05015) + (xy 89.33096 38.023445) (xy 89.473606 38.009063) (xy 149.013379 35.685) (xy 170.896299 35.685) + ) + ) + (filled_polygon + (pts + (xy 173.005405 121.897808) (xy 173.029199 121.926801) (xy 173.058192 121.950595) (xy 173.058196 121.950599) (xy 173.116778 121.998675) + (xy 173.144924 122.021774) (xy 173.276953 122.092346) (xy 173.420214 122.135803) (xy 173.531867 122.1468) (xy 173.531876 122.1468) + (xy 173.569199 122.150476) (xy 173.606522 122.1468) (xy 175.47541 122.1468) (xy 175.220583 122.528175) (xy 175.018183 123.016814) + (xy 174.915 123.535551) (xy 174.915 124.064449) (xy 175.018183 124.583186) (xy 175.023749 124.596623) (xy 174.801302 124.447989) + (xy 174.492012 124.319877) (xy 174.527932 124.233158) (xy 174.585 123.94626) (xy 174.585 123.65374) (xy 174.527932 123.366842) + (xy 174.41599 123.096589) (xy 174.253475 122.853368) (xy 174.046632 122.646525) (xy 173.803411 122.48401) (xy 173.533158 122.372068) + (xy 173.24626 122.315) (xy 173.076697 122.315) (xy 172.982327 122.275911) (xy 172.676109 122.215) (xy 172.363891 122.215) + (xy 172.057673 122.275911) (xy 171.769221 122.395391) (xy 171.509621 122.56885) (xy 171.28885 122.789621) (xy 171.115391 123.049221) + (xy 170.995911 123.337673) (xy 170.935 123.643891) (xy 170.935 123.956109) (xy 170.995911 124.262327) (xy 171.115391 124.550779) + (xy 171.243113 124.741928) (xy 169.45 124.741928) (xy 169.325518 124.754188) (xy 169.20582 124.790498) (xy 169.095506 124.849463) + (xy 168.998815 124.928815) (xy 168.919463 125.025506) (xy 168.860498 125.13582) (xy 168.824188 125.255518) (xy 168.811928 125.38) + (xy 168.811928 127.38) (xy 168.824188 127.504482) (xy 168.860498 127.62418) (xy 168.919463 127.734494) (xy 168.998815 127.831185) + (xy 169.095506 127.910537) (xy 169.20582 127.969502) (xy 169.325518 128.005812) (xy 169.45 128.018072) (xy 169.84 128.018072) + (xy 169.84 128.233697) (xy 169.479697 128.594001) (xy 164.4408 128.594001) (xy 164.811002 128.2238) (xy 164.840001 128.200001) + (xy 164.934974 128.084276) (xy 164.954326 128.048072) (xy 165.45 128.048072) (xy 165.574482 128.035812) (xy 165.69418 127.999502) + (xy 165.804494 127.940537) (xy 165.901185 127.861185) (xy 165.980537 127.764494) (xy 166.039502 127.65418) (xy 166.075812 127.534482) + (xy 166.088072 127.41) (xy 166.088072 127.17) (xy 166.813721 127.17) (xy 166.94484 127.224311) (xy 167.10616 127.2564) + (xy 167.27064 127.2564) (xy 167.43196 127.224311) (xy 167.583921 127.161367) (xy 167.720681 127.069987) (xy 167.836987 126.953681) + (xy 167.928367 126.816921) (xy 167.991311 126.66496) (xy 168.0234 126.50364) (xy 168.0234 126.33916) (xy 167.991311 126.17784) + (xy 167.928367 126.025879) (xy 167.836987 125.889119) (xy 167.720681 125.772813) (xy 167.583921 125.681433) (xy 167.43196 125.618489) + (xy 167.27064 125.5864) (xy 167.10616 125.5864) (xy 166.94484 125.618489) (xy 166.868765 125.65) (xy 166.088072 125.65) + (xy 166.088072 125.41) (xy 166.075812 125.285518) (xy 166.039502 125.16582) (xy 165.980537 125.055506) (xy 165.901185 124.958815) + (xy 165.804494 124.879463) (xy 165.69418 124.820498) (xy 165.574482 124.784188) (xy 165.45 124.771928) (xy 164.330748 124.771928) + (xy 164.462953 124.452756) (xy 164.545 124.040279) (xy 164.545 123.619721) (xy 164.462953 123.207244) (xy 164.302012 122.818698) + (xy 164.264985 122.763283) (xy 164.430779 122.694609) (xy 164.690379 122.52115) (xy 164.91115 122.300379) (xy 165.084609 122.040779) + (xy 165.204089 121.752327) (xy 165.265 121.446109) (xy 165.265 121.133891) (xy 165.204089 120.827673) (xy 165.084609 120.539221) + (xy 164.91115 120.279621) (xy 164.690379 120.05885) (xy 164.430779 119.885391) (xy 164.142327 119.765911) (xy 163.836109 119.705) + (xy 163.523891 119.705) (xy 163.217673 119.765911) (xy 163.123303 119.805) (xy 162.95374 119.805) (xy 162.666842 119.862068) + (xy 162.396589 119.97401) (xy 162.153368 120.136525) (xy 161.946525 120.343368) (xy 161.78401 120.586589) (xy 161.672068 120.856842) + (xy 161.615 121.14374) (xy 161.615 121.43626) (xy 161.672068 121.723158) (xy 161.707988 121.809876) (xy 161.398698 121.937988) + (xy 161.176252 122.086622) (xy 161.181817 122.073186) (xy 161.285 121.554449) (xy 161.285 121.025551) (xy 161.181817 120.506814) + (xy 160.979417 120.018175) (xy 160.750114 119.674999) (xy 170.782598 119.674999) + ) + ) + (filled_polygon + (pts + (xy 105.060498 124.26082) (xy 105.024188 124.380518) (xy 105.011928 124.505) (xy 105.015 124.71925) (xy 105.17375 124.878) + (xy 106.523 124.878) (xy 106.523 124.858) (xy 106.777 124.858) (xy 106.777 124.878) (xy 106.797 124.878) + (xy 106.797 125.132) (xy 106.777 125.132) (xy 106.777 125.152) (xy 106.523 125.152) (xy 106.523 125.132) + (xy 105.17375 125.132) (xy 105.015 125.29075) (xy 105.011928 125.505) (xy 105.024188 125.629482) (xy 105.060498 125.74918) + (xy 105.119463 125.859494) (xy 105.198815 125.956185) (xy 105.295138 126.035235) (xy 105.265099 126.107755) (xy 105.23301 126.269075) + (xy 105.23301 126.433555) (xy 105.265099 126.594875) (xy 105.308011 126.698474) (xy 105.30801 128.078378) (xy 105.306511 128.07084) + (xy 105.243567 127.918879) (xy 105.152187 127.782119) (xy 105.035881 127.665813) (xy 104.899121 127.574433) (xy 104.74716 127.511489) + (xy 104.671176 127.496375) (xy 104.283141 127.10834) (xy 104.259339 127.079337) (xy 104.143614 126.984364) (xy 104.011585 126.913792) + (xy 103.868324 126.870335) (xy 103.756671 126.859338) (xy 103.75666 126.859338) (xy 103.719338 126.855662) (xy 103.682016 126.859338) + (xy 101.607306 126.859338) (xy 101.543653 126.770509) (xy 101.452359 126.685003) (xy 101.346137 126.61895) (xy 101.22907 126.574889) + (xy 101.105657 126.554513) (xy 100.98064 126.558606) (xy 100.858824 126.587009) (xy 100.744889 126.638632) (xy 100.653371 126.69147) + (xy 100.621149 126.665026) (xy 100.48912 126.594454) (xy 100.345859 126.550997) (xy 100.234206 126.54) (xy 100.234195 126.54) + (xy 100.196873 126.536324) (xy 100.159551 126.54) (xy 99.349925 126.54) (xy 99.3126 126.536324) (xy 99.275275 126.54) + (xy 99.275267 126.54) (xy 99.219258 126.545517) (xy 99.157787 126.453519) (xy 99.041481 126.337213) (xy 98.904721 126.245833) + (xy 98.851156 126.223646) (xy 99.314803 125.76) (xy 100.827843 125.76) (xy 100.93144 125.802911) (xy 101.09276 125.835) + (xy 101.25724 125.835) (xy 101.41856 125.802911) (xy 101.570521 125.739967) (xy 101.707281 125.648587) (xy 101.823587 125.532281) + (xy 101.914967 125.395521) (xy 101.957879 125.291922) (xy 102.01373 125.236071) (xy 101.999179 125.28404) (xy 101.937089 125.43394) + (xy 101.905 125.59526) (xy 101.905 125.75974) (xy 101.937089 125.92106) (xy 102.000033 126.073021) (xy 102.091413 126.209781) + (xy 102.207719 126.326087) (xy 102.344479 126.417467) (xy 102.49644 126.480411) (xy 102.65776 126.5125) (xy 102.82224 126.5125) + (xy 102.98356 126.480411) (xy 103.135521 126.417467) (xy 103.272281 126.326087) (xy 103.388587 126.209781) (xy 103.479967 126.073021) + (xy 103.542911 125.92106) (xy 103.575 125.75974) (xy 103.575 125.699801) (xy 105.113913 124.160888) + ) + ) + (filled_polygon + (pts + (xy 190.5384 119.566442) (xy 190.495489 119.67004) (xy 190.4634 119.83136) (xy 190.4634 119.99584) (xy 190.495489 120.15716) + (xy 190.558433 120.309121) (xy 190.649813 120.445881) (xy 190.742815 120.538883) (xy 183.999771 127.281928) (xy 183.330748 127.281928) + (xy 183.462953 126.962756) (xy 183.545 126.550279) (xy 183.545 126.129721) (xy 183.462953 125.717244) (xy 183.302012 125.328698) + (xy 183.264985 125.273283) (xy 183.430779 125.204609) (xy 183.690379 125.03115) (xy 183.91115 124.810379) (xy 184.084609 124.550779) + (xy 184.204089 124.262327) (xy 184.265 123.956109) (xy 184.265 123.643891) (xy 184.204089 123.337673) (xy 184.182271 123.284999) + (xy 186.390215 123.284999) (xy 186.427537 123.288675) (xy 186.464859 123.284999) (xy 186.46487 123.284999) (xy 186.576523 123.274002) + (xy 186.719784 123.230545) (xy 186.851813 123.159973) (xy 186.967538 123.065) (xy 186.991341 123.035996) (xy 187.694265 122.333072) + (xy 188.25 122.333072) (xy 188.374482 122.320812) (xy 188.49418 122.284502) (xy 188.604494 122.225537) (xy 188.701185 122.146185) + (xy 188.780537 122.049494) (xy 188.839502 121.93918) (xy 188.875812 121.819482) (xy 188.888072 121.695) (xy 188.888072 121.139266) + (xy 189.114392 120.912946) (xy 189.217989 120.870035) (xy 189.354749 120.778655) (xy 189.471055 120.662349) (xy 189.562435 120.525589) + (xy 189.625379 120.373628) (xy 189.657468 120.212308) (xy 189.657468 120.047828) (xy 189.644001 119.980127) (xy 189.663803 119.955998) + (xy 190.160268 119.459533) (xy 190.19356 119.452911) (xy 190.345521 119.389967) (xy 190.482281 119.298587) (xy 190.538401 119.242467) + ) + ) + (filled_polygon + (pts + (xy 121.970889 118.77644) (xy 121.9388 118.93776) (xy 121.9388 119.10224) (xy 121.970889 119.26356) (xy 121.972601 119.267693) + (xy 121.9726 120.695267) (xy 121.9726 121.057332) (xy 121.972601 121.057339) (xy 121.9726 121.385442) (xy 121.929689 121.48904) + (xy 121.8976 121.65036) (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.972601 122.079759) (xy 121.9726 122.985443) + (xy 121.929689 123.08904) (xy 121.8976 123.25036) (xy 121.8976 123.41484) (xy 121.929689 123.57616) (xy 121.9726 123.679757) + (xy 121.9726 123.895278) (xy 121.968924 123.9326) (xy 121.9726 123.969922) (xy 121.9726 123.969932) (xy 121.983597 124.081585) + (xy 122.01936 124.199482) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.135493 124.403017) (xy 122.192599 124.472601) + (xy 122.221603 124.496404) (xy 122.436196 124.710997) (xy 122.459999 124.740001) (xy 122.575724 124.834974) (xy 122.707753 124.905546) + (xy 122.762007 124.922004) (xy 122.771627 124.940001) (xy 120.62351 124.940001) (xy 120.635 124.88224) (xy 120.635 124.71776) + (xy 120.602911 124.55644) (xy 120.539967 124.404479) (xy 120.448587 124.267719) (xy 120.332281 124.151413) (xy 120.195521 124.060033) + (xy 120.092926 124.017537) (xy 120.103062 124.008044) (xy 120.175921 123.906371) (xy 120.227543 123.792437) (xy 120.255948 123.67062) + (xy 120.26004 123.545603) (xy 120.239664 123.422189) (xy 120.181245 123.216035) (xy 119.986819 123.103783) (xy 120.140158 123.062696) + (xy 120.130182 123.025464) (xy 120.24356 123.002911) (xy 120.395521 122.939967) (xy 120.532281 122.848587) (xy 120.648587 122.732281) + (xy 120.739967 122.595521) (xy 120.802911 122.44356) (xy 120.835 122.28224) (xy 120.835 122.11776) (xy 120.802911 121.95644) + (xy 120.739967 121.804479) (xy 120.648587 121.667719) (xy 120.532281 121.551413) (xy 120.395521 121.460033) (xy 120.24356 121.397089) + (xy 120.08224 121.365) (xy 119.91776 121.365) (xy 119.75644 121.397089) (xy 119.702974 121.419235) (xy 119.527912 120.765894) + (xy 119.483851 120.648827) (xy 119.417799 120.542605) (xy 119.332292 120.451311) (xy 119.230618 120.378453) (xy 119.116684 120.326829) + (xy 118.994867 120.298426) (xy 118.86985 120.294333) (xy 118.746437 120.314709) (xy 118.085658 120.491764) (xy 118.027859 120.276054) + (xy 118.022151 120.241484) (xy 118.009809 120.208692) (xy 118.009807 120.208684) (xy 117.972887 120.11059) (xy 117.899032 119.991823) + (xy 117.803427 119.889746) (xy 117.689744 119.808281) (xy 117.562352 119.750561) (xy 117.426149 119.718803) (xy 117.286366 119.714227) + (xy 117.286365 119.714227) (xy 117.182953 119.7313) (xy 117.182948 119.731301) (xy 117.148377 119.737009) (xy 117.115583 119.749352) + (xy 116.935 119.797739) (xy 116.935 119.71776) (xy 116.902911 119.55644) (xy 116.86 119.452843) (xy 116.86 119.214802) + (xy 117.213799 118.861004) (xy 117.213808 118.860993) (xy 117.439809 118.634992) (xy 122.029478 118.634992) + ) + ) + (filled_polygon + (pts + (xy 130.529667 121.6642) (xy 130.529676 121.6642) (xy 130.566999 121.667876) (xy 130.604322 121.6642) (xy 137.738636 121.6642) + (xy 137.414424 121.988412) (xy 137.120583 122.428175) (xy 136.918183 122.916814) (xy 136.815 123.435551) (xy 136.815 123.964449) + (xy 136.918183 124.483186) (xy 136.923749 124.496623) (xy 136.701302 124.347989) (xy 136.392012 124.219877) (xy 136.427932 124.133158) + (xy 136.485 123.84626) (xy 136.485 123.55374) (xy 136.427932 123.266842) (xy 136.31599 122.996589) (xy 136.153475 122.753368) + (xy 135.946632 122.546525) (xy 135.703411 122.38401) (xy 135.433158 122.272068) (xy 135.14626 122.215) (xy 134.976697 122.215) + (xy 134.882327 122.175911) (xy 134.576109 122.115) (xy 134.263891 122.115) (xy 133.957673 122.175911) (xy 133.669221 122.295391) + (xy 133.409621 122.46885) (xy 133.18885 122.689621) (xy 133.015391 122.949221) (xy 132.895911 123.237673) (xy 132.835 123.543891) + (xy 132.835 123.856109) (xy 132.895911 124.162327) (xy 133.015391 124.450779) (xy 133.143113 124.641928) (xy 131.391729 124.641928) + (xy 130.438804 123.689003) (xy 130.415001 123.659999) (xy 130.299276 123.565026) (xy 130.167247 123.494454) (xy 130.023986 123.450997) + (xy 129.912333 123.44) (xy 129.912322 123.44) (xy 129.875 123.436324) (xy 129.837678 123.44) (xy 129.347157 123.44) + (xy 129.24356 123.397089) (xy 129.08224 123.365) (xy 128.91776 123.365) (xy 128.75644 123.397089) (xy 128.746866 123.401055) + (xy 128.730537 123.370506) (xy 128.651185 123.273815) (xy 128.554494 123.194463) (xy 128.44418 123.135498) (xy 128.324482 123.099188) + (xy 128.2 123.086928) (xy 126.96 123.086928) (xy 126.96 122.713072) (xy 128.2 122.713072) (xy 128.324482 122.700812) + (xy 128.44418 122.664502) (xy 128.554494 122.605537) (xy 128.651185 122.526185) (xy 128.730537 122.429494) (xy 128.767683 122.36) + (xy 128.966799 122.36) (xy 128.996721 122.389922) (xy 129.039633 122.493521) (xy 129.131013 122.630281) (xy 129.247319 122.746587) + (xy 129.384079 122.837967) (xy 129.53604 122.900911) (xy 129.69736 122.933) (xy 129.86184 122.933) (xy 130.02316 122.900911) + (xy 130.175121 122.837967) (xy 130.311881 122.746587) (xy 130.428187 122.630281) (xy 130.519567 122.493521) (xy 130.582511 122.34156) + (xy 130.6146 122.18024) (xy 130.6146 122.01576) (xy 130.582511 121.85444) (xy 130.519567 121.702479) (xy 130.491476 121.660439) + ) + ) + (filled_polygon + (pts + (xy 118.810987 123.155884) (xy 118.830305 123.150708) (xy 118.896046 123.396054) (xy 118.876727 123.40123) (xy 118.881903 123.420548) + (xy 118.871193 123.423418) (xy 118.7951 123.139435) (xy 118.805811 123.136565) + ) + ) + (filled_polygon + (pts + (xy 190.787398 118.39819) (xy 190.7584 118.421988) (xy 190.756471 118.424338) (xy 190.752911 118.40644) (xy 190.689967 118.254479) + (xy 190.598587 118.117719) (xy 190.482281 118.001413) (xy 190.345521 117.910033) (xy 190.19356 117.847089) (xy 190.03224 117.815) + (xy 189.86776 117.815) (xy 189.70644 117.847089) (xy 189.554479 117.910033) (xy 189.417719 118.001413) (xy 189.301413 118.117719) + (xy 189.210033 118.254479) (xy 189.206012 118.264186) (xy 188.815076 118.655123) (xy 188.780537 118.590506) (xy 188.701185 118.493815) + (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) (xy 188.25 118.306928) (xy 186.25 118.306928) + (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) (xy 185.798815 118.493815) (xy 185.719463 118.590506) + (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) (xy 185.611928 119.945) (xy 185.624188 120.069482) + (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) (xy 185.719463 120.340506) (xy 185.660498 120.45082) + (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.695) (xy 185.618822 121.764999) (xy 184.481178 121.764999) + (xy 184.488072 121.695) (xy 184.485 121.48075) (xy 184.32625 121.322) (xy 182.977 121.322) (xy 182.977 121.342) + (xy 182.723 121.342) (xy 182.723 121.322) (xy 181.37375 121.322) (xy 181.215 121.48075) (xy 181.211928 121.695) + (xy 181.218822 121.764999) (xy 180.154804 121.764999) (xy 179.592903 121.2031) (xy 179.62182 121.194328) (xy 179.745163 121.1284) + (xy 179.853275 121.039675) (xy 179.942 120.931563) (xy 180.007928 120.80822) (xy 180.048527 120.674384) (xy 180.0588 120.570077) + (xy 180.0588 120.570076) (xy 180.062235 120.5352) (xy 180.0588 120.500323) (xy 180.0588 120.31) (xy 180.127002 120.31) + (xy 180.127002 120.151252) (xy 180.278 120.30225) (xy 180.278 120.32604) (xy 180.310089 120.48736) (xy 180.373033 120.639321) + (xy 180.464413 120.776081) (xy 180.580719 120.892387) (xy 180.717479 120.983767) (xy 180.86944 121.046711) (xy 181.03076 121.0788) + (xy 181.19524 121.0788) (xy 181.353141 121.047391) (xy 181.37375 121.068) (xy 182.723 121.068) (xy 182.723 121.048) + (xy 182.977 121.048) (xy 182.977 121.068) (xy 184.32625 121.068) (xy 184.485 120.90925) (xy 184.488072 120.695) + (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) (xy 184.363708 120.32) (xy 184.380537 120.299494) + (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) (xy 184.488072 118.945) (xy 184.475812 118.820518) + (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) (xy 184.379711 118.35376) + (xy 184.403516 118.234088) (xy 185.418404 117.2192) (xy 191.966387 117.2192) + ) + ) + (filled_polygon + (pts + (xy 111.711928 91.68) (xy 111.724188 91.804482) (xy 111.760498 91.92418) (xy 111.819463 92.034494) (xy 111.898815 92.131185) + (xy 111.995506 92.210537) (xy 112.10582 92.269502) (xy 112.225518 92.305812) (xy 112.266392 92.309838) (xy 112.247089 92.35644) + (xy 112.215 92.51776) (xy 112.215 92.68224) (xy 112.247089 92.84356) (xy 112.310033 92.995521) (xy 112.401413 93.132281) + (xy 112.517719 93.248587) (xy 112.654479 93.339967) (xy 112.80644 93.402911) (xy 112.96776 93.435) (xy 113.13224 93.435) + (xy 113.29356 93.402911) (xy 113.445521 93.339967) (xy 113.582281 93.248587) (xy 113.698587 93.132281) (xy 113.789967 92.995521) + (xy 113.852911 92.84356) (xy 113.885 92.68224) (xy 113.885 92.51776) (xy 113.852911 92.35644) (xy 113.837019 92.318072) + (xy 114.65 92.318072) (xy 114.774482 92.305812) (xy 114.89418 92.269502) (xy 115.004494 92.210537) (xy 115.101185 92.131185) + (xy 115.128525 92.097872) (xy 115.329017 92.298364) (xy 115.678698 92.532013) (xy 115.894302 92.621319) (xy 115.825 92.969721) + (xy 115.825 93.390279) (xy 115.907047 93.802756) (xy 116.067988 94.191302) (xy 116.301637 94.540983) (xy 116.599017 94.838363) + (xy 116.948698 95.072012) (xy 117.337244 95.232953) (xy 117.749721 95.315) (xy 117.810196 95.315) (xy 115.249503 97.875694) + (xy 115.220499 97.899497) (xy 115.175558 97.954258) (xy 115.125526 98.015222) (xy 115.078139 98.103876) (xy 115.054954 98.147252) + (xy 115.011497 98.290513) (xy 115.0005 98.402166) (xy 115.0005 98.402176) (xy 114.996824 98.439498) (xy 115.0005 98.476821) + (xy 115.000501 104.022767) (xy 114.996824 104.060099) (xy 115.000501 104.097432) (xy 115.011498 104.209085) (xy 115.02017 104.237673) + (xy 115.054954 104.352345) (xy 115.125526 104.484375) (xy 115.195319 104.569417) (xy 115.2205 104.6001) (xy 115.249498 104.623898) + (xy 116.264023 105.638425) (xy 116.14626 105.615) (xy 115.976697 105.615) (xy 115.882327 105.575911) (xy 115.576109 105.515) + (xy 115.263891 105.515) (xy 114.957673 105.575911) (xy 114.669221 105.695391) (xy 114.409621 105.86885) (xy 114.18885 106.089621) + (xy 114.015391 106.349221) (xy 113.895911 106.637673) (xy 113.835 106.943891) (xy 113.835 107.256109) (xy 113.895911 107.562327) + (xy 114.015391 107.850779) (xy 114.143113 108.041928) (xy 112.35 108.041928) (xy 112.225518 108.054188) (xy 112.10582 108.090498) + (xy 111.995506 108.149463) (xy 111.898815 108.228815) (xy 111.819463 108.325506) (xy 111.760498 108.43582) (xy 111.724188 108.555518) + (xy 111.711928 108.68) (xy 111.711928 110.68) (xy 111.724188 110.804482) (xy 111.760498 110.92418) (xy 111.819463 111.034494) + (xy 111.898815 111.131185) (xy 111.995506 111.210537) (xy 111.9962 111.210908) (xy 111.965 111.36776) (xy 111.965 111.441408) + (xy 111.83224 111.415) (xy 111.66776 111.415) (xy 111.50644 111.447089) (xy 111.354479 111.510033) (xy 111.217719 111.601413) + (xy 111.101413 111.717719) (xy 111.010033 111.854479) (xy 110.947089 112.00644) (xy 110.915 112.16776) (xy 110.915 112.33224) + (xy 110.947089 112.49356) (xy 111.010033 112.645521) (xy 111.101413 112.782281) (xy 111.217719 112.898587) (xy 111.354479 112.989967) + (xy 111.458078 113.032879) (xy 112.686201 114.261003) (xy 112.709999 114.290001) (xy 112.825724 114.384974) (xy 112.957753 114.455546) + (xy 113.101014 114.499003) (xy 113.212667 114.51) (xy 113.212676 114.51) (xy 113.249999 114.513676) (xy 113.287322 114.51) + (xy 113.902843 114.51) (xy 114.00644 114.552911) (xy 114.16776 114.585) (xy 114.33224 114.585) (xy 114.49356 114.552911) + (xy 114.645521 114.489967) (xy 114.782281 114.398587) (xy 114.898587 114.282281) (xy 114.989967 114.145521) (xy 115.052911 113.99356) + (xy 115.085 113.83224) (xy 115.085 113.66776) (xy 115.052911 113.50644) (xy 114.989967 113.354479) (xy 114.898587 113.217719) + (xy 114.782281 113.101413) (xy 114.645521 113.010033) (xy 114.49356 112.947089) (xy 114.33224 112.915) (xy 114.16776 112.915) + (xy 114.00644 112.947089) (xy 113.902843 112.99) (xy 113.564802 112.99) (xy 112.859801 112.285) (xy 112.88224 112.285) + (xy 113.04356 112.252911) (xy 113.195521 112.189967) (xy 113.332281 112.098587) (xy 113.448587 111.982281) (xy 113.539967 111.845521) + (xy 113.602911 111.69356) (xy 113.635 111.53224) (xy 113.635 111.36776) (xy 113.625116 111.318072) (xy 114.65 111.318072) + (xy 114.774482 111.305812) (xy 114.89418 111.269502) (xy 115.004494 111.210537) (xy 115.101185 111.131185) (xy 115.128525 111.097872) + (xy 115.329017 111.298364) (xy 115.678698 111.532013) (xy 115.894302 111.621319) (xy 115.825 111.969721) (xy 115.825 112.390279) + (xy 115.907047 112.802756) (xy 116.067988 113.191302) (xy 116.301637 113.540983) (xy 116.599017 113.838363) (xy 116.948698 114.072012) + (xy 117.188619 114.171391) (xy 117.105023 114.239996) (xy 117.081225 114.268994) (xy 112.608078 118.742142) (xy 112.504479 118.785054) + (xy 112.367719 118.876434) (xy 112.251413 118.99274) (xy 112.160033 119.1295) (xy 112.097089 119.281461) (xy 112.065 119.442781) + (xy 112.065 119.511728) (xy 111.5498 119.511728) (xy 111.425318 119.523988) (xy 111.30562 119.560298) (xy 111.195306 119.619263) + (xy 111.098615 119.698615) (xy 111.019263 119.795306) (xy 110.960298 119.90562) (xy 110.923988 120.025318) (xy 110.911728 120.1498) + (xy 110.911728 120.233468) (xy 110.693076 120.45212) (xy 110.639978 120.474114) (xy 110.630994 120.474999) (xy 110.630985 120.474999) + (xy 110.519332 120.485996) (xy 110.376071 120.529453) (xy 110.244042 120.600025) (xy 110.128317 120.694998) (xy 110.104519 120.723996) + (xy 109.937872 120.890643) (xy 109.937872 120.482188) (xy 110.044581 120.410887) (xy 110.160887 120.294581) (xy 110.252267 120.157821) + (xy 110.295178 120.054224) (xy 110.511003 119.838399) (xy 110.540001 119.814601) (xy 110.581828 119.763635) (xy 110.634974 119.698877) + (xy 110.705546 119.566847) (xy 110.718001 119.525788) (xy 110.749003 119.423586) (xy 110.76 119.311933) (xy 110.76 119.311924) + (xy 110.763676 119.274601) (xy 110.76 119.237278) (xy 110.76 102.037323) (xy 110.763676 102) (xy 110.76 101.962677) + (xy 110.76 101.962667) (xy 110.749003 101.851014) (xy 110.705546 101.707753) (xy 110.634974 101.575724) (xy 110.540001 101.459999) + (xy 110.511004 101.436202) (xy 109.399802 100.325) (xy 110.886928 100.325) (xy 110.886928 101.625) (xy 110.899188 101.749482) + (xy 110.935498 101.86918) (xy 110.994463 101.979494) (xy 111.073815 102.076185) (xy 111.167863 102.153368) (xy 111.165 102.16776) + (xy 111.165 102.33224) (xy 111.197089 102.49356) (xy 111.260033 102.645521) (xy 111.329844 102.75) (xy 111.260033 102.854479) + (xy 111.197089 103.00644) (xy 111.165 103.16776) (xy 111.165 103.33224) (xy 111.167863 103.346632) (xy 111.073815 103.423815) + (xy 110.994463 103.520506) (xy 110.935498 103.63082) (xy 110.899188 103.750518) (xy 110.886928 103.875) (xy 110.886928 105.175) + (xy 110.899188 105.299482) (xy 110.935498 105.41918) (xy 110.994463 105.529494) (xy 111.073815 105.626185) (xy 111.170506 105.705537) + (xy 111.28082 105.764502) (xy 111.400518 105.800812) (xy 111.525 105.813072) (xy 112.475 105.813072) (xy 112.599482 105.800812) + (xy 112.71918 105.764502) (xy 112.829494 105.705537) (xy 112.926185 105.626185) (xy 113.005537 105.529494) (xy 113.064502 105.41918) + (xy 113.100812 105.299482) (xy 113.113072 105.175) (xy 113.113072 103.875) (xy 113.100812 103.750518) (xy 113.064502 103.63082) + (xy 113.005537 103.520506) (xy 112.926185 103.423815) (xy 112.832137 103.346632) (xy 112.835 103.33224) (xy 112.835 103.16776) + (xy 112.802911 103.00644) (xy 112.739967 102.854479) (xy 112.670156 102.75) (xy 112.739967 102.645521) (xy 112.802911 102.49356) + (xy 112.835 102.33224) (xy 112.835 102.16776) (xy 112.832137 102.153368) (xy 112.926185 102.076185) (xy 113.005537 101.979494) + (xy 113.064502 101.86918) (xy 113.100812 101.749482) (xy 113.113072 101.625) (xy 113.113072 100.325) (xy 113.100812 100.200518) + (xy 113.064502 100.08082) (xy 113.005537 99.970506) (xy 112.926185 99.873815) (xy 112.829494 99.794463) (xy 112.71918 99.735498) + (xy 112.599482 99.699188) (xy 112.475 99.686928) (xy 111.525 99.686928) (xy 111.400518 99.699188) (xy 111.28082 99.735498) + (xy 111.170506 99.794463) (xy 111.073815 99.873815) (xy 110.994463 99.970506) (xy 110.935498 100.08082) (xy 110.899188 100.200518) + (xy 110.886928 100.325) (xy 109.399802 100.325) (xy 107.682825 98.608024) (xy 107.69276 98.61) (xy 107.85724 98.61) + (xy 108.01856 98.577911) (xy 108.170521 98.514967) (xy 108.307281 98.423587) (xy 108.423587 98.307281) (xy 108.514967 98.170521) + (xy 108.538763 98.113072) (xy 109.425 98.113072) (xy 109.549482 98.100812) (xy 109.66918 98.064502) (xy 109.779494 98.005537) + (xy 109.876185 97.926185) (xy 109.955537 97.829494) (xy 110.014502 97.71918) (xy 110.033093 97.657894) (xy 110.638835 98.263637) + (xy 110.701414 98.357293) (xy 110.81772 98.473599) (xy 110.95448 98.564979) (xy 111.106441 98.627923) (xy 111.267761 98.660012) + (xy 111.432241 98.660012) (xy 111.593561 98.627923) (xy 111.745522 98.564979) (xy 111.882282 98.473599) (xy 111.998588 98.357293) + (xy 112.089968 98.220533) (xy 112.152912 98.068572) (xy 112.185001 97.907252) (xy 112.185001 97.742772) (xy 112.152912 97.581452) + (xy 112.089968 97.429491) (xy 111.998588 97.292731) (xy 111.882282 97.176425) (xy 111.745522 97.085045) (xy 111.593561 97.022101) + (xy 111.535317 97.010515) (xy 111.01 96.485199) (xy 111.01 90.554616) (xy 111.01857 90.552911) (xy 111.170531 90.489967) + (xy 111.307291 90.398587) (xy 111.423597 90.282281) (xy 111.514977 90.145521) (xy 111.561375 90.033506) (xy 111.609983 89.974277) + (xy 111.680555 89.842248) (xy 111.711928 89.738823) + ) + ) + (filled_polygon + (pts + (xy 165.658073 112.848531) (xy 165.554475 112.891443) (xy 165.417715 112.982823) (xy 165.301409 113.099129) (xy 165.210029 113.235889) + (xy 165.147085 113.38785) (xy 165.114996 113.54917) (xy 165.114996 113.71365) (xy 165.147085 113.87497) (xy 165.210029 114.026931) + (xy 165.301409 114.163691) (xy 165.417715 114.279997) (xy 165.554475 114.371377) (xy 165.706436 114.434321) (xy 165.867756 114.46641) + (xy 166.032236 114.46641) (xy 166.193556 114.434321) (xy 166.345517 114.371377) (xy 166.482277 114.279997) (xy 166.598583 114.163691) + (xy 166.689963 114.026931) (xy 166.732875 113.923333) (xy 167.482103 113.174104) (xy 171.998922 117.690924) (xy 172.041833 117.794521) + (xy 172.133213 117.931281) (xy 172.249519 118.047587) (xy 172.386279 118.138967) (xy 172.53824 118.201911) (xy 172.69956 118.234) + (xy 172.86404 118.234) (xy 172.9882 118.209303) (xy 172.9882 118.37024) (xy 173.020289 118.53156) (xy 173.083233 118.683521) + (xy 173.174613 118.820281) (xy 173.290919 118.936587) (xy 173.427679 119.027967) (xy 173.57964 119.090911) (xy 173.74096 119.123) + (xy 173.761928 119.123) (xy 173.761928 119.675) (xy 173.774188 119.799482) (xy 173.810498 119.91918) (xy 173.869463 120.029494) + (xy 173.948815 120.126185) (xy 174.045506 120.205537) (xy 174.15582 120.264502) (xy 174.275518 120.300812) (xy 174.4 120.313072) + (xy 175.1388 120.313072) (xy 175.1388 120.500323) (xy 175.135365 120.5352) (xy 175.144387 120.6268) (xy 173.884003 120.6268) + (xy 171.661203 118.404002) (xy 171.6374 118.374998) (xy 171.521675 118.280025) (xy 171.389646 118.209453) (xy 171.246385 118.165996) + (xy 171.134732 118.154999) (xy 171.134721 118.154999) (xy 171.097399 118.151323) (xy 171.060077 118.154999) (xy 161.052135 118.154999) + (xy 161.063835 118.0362) (xy 161.0604 118.001323) (xy 161.0604 117.8) (xy 161.127002 117.8) (xy 161.127002 117.641252) + (xy 161.28575 117.8) (xy 161.8 117.803072) (xy 161.924482 117.790812) (xy 162.04418 117.754502) (xy 162.154494 117.695537) + (xy 162.251185 117.616185) (xy 162.330537 117.519494) (xy 162.389502 117.40918) (xy 162.425812 117.289482) (xy 162.438072 117.165) + (xy 162.435 116.95075) (xy 162.27625 116.792) (xy 161.127 116.792) (xy 161.127 116.812) (xy 161.0604 116.812) + (xy 161.0604 116.518) (xy 161.127 116.518) (xy 161.127 116.538) (xy 162.27625 116.538) (xy 162.435 116.37925) + (xy 162.438072 116.165) (xy 162.425812 116.040518) (xy 162.389502 115.92082) (xy 162.330537 115.810506) (xy 162.313708 115.79) + (xy 162.330537 115.769494) (xy 162.389502 115.65918) (xy 162.425812 115.539482) (xy 162.427882 115.518463) (xy 162.505211 115.455001) + (xy 162.529013 115.425998) (xy 162.785512 115.169499) (xy 162.88911 115.126588) (xy 163.02587 115.035208) (xy 163.142176 114.918902) + (xy 163.233556 114.782142) (xy 163.2965 114.630181) (xy 163.328589 114.468861) (xy 163.328589 114.304381) (xy 163.2965 114.143061) + (xy 163.233556 113.9911) (xy 163.142176 113.85434) (xy 163.02587 113.738034) (xy 162.88911 113.646654) (xy 162.737149 113.58371) + (xy 162.575829 113.551621) (xy 162.411349 113.551621) (xy 162.250029 113.58371) (xy 162.098068 113.646654) (xy 161.961308 113.738034) + (xy 161.911439 113.787903) (xy 161.8 113.776928) (xy 161.76 113.776928) (xy 161.76 113.223722) (xy 161.763676 113.186399) + (xy 161.76 113.149076) (xy 161.76 113.149067) (xy 161.749003 113.037414) (xy 161.705546 112.894153) (xy 161.634974 112.762124) + (xy 161.625032 112.75001) (xy 165.756595 112.75001) + ) + ) + (filled_polygon + (pts + (xy 143.35451 118.795112) (xy 143.383513 118.818914) (xy 144.708799 120.1442) (xy 142.982162 120.1442) (xy 143.054494 120.105537) + (xy 143.151185 120.026185) (xy 143.230537 119.929494) (xy 143.289502 119.81918) (xy 143.325812 119.699482) (xy 143.338072 119.575) + (xy 143.335 119.36075) (xy 143.17625 119.202) (xy 142.027 119.202) (xy 142.027 119.222) (xy 141.9604 119.222) + (xy 141.9604 118.928) (xy 142.027 118.928) (xy 142.027 118.948) (xy 143.17625 118.948) (xy 143.335 118.78925) + (xy 143.335252 118.771647) + ) + ) + (filled_polygon + (pts + (xy 129.628319 116.066387) (xy 129.765079 116.157767) (xy 129.91704 116.220711) (xy 130.07836 116.2528) (xy 130.24284 116.2528) + (xy 130.40416 116.220711) (xy 130.507757 116.1778) (xy 132.493799 116.1778) (xy 134.336599 118.020601) (xy 134.336599 118.137941) + (xy 134.332923 118.175263) (xy 134.336599 118.212585) (xy 134.336599 118.212596) (xy 134.347596 118.324249) (xy 134.391053 118.46751) + (xy 134.461625 118.599539) (xy 134.556599 118.715264) (xy 134.585597 118.739062) (xy 134.88659 119.040055) (xy 134.929501 119.143653) + (xy 135.020881 119.280413) (xy 135.137187 119.396719) (xy 135.273947 119.488099) (xy 135.425908 119.551043) (xy 135.587228 119.583132) + (xy 135.662729 119.583132) (xy 135.674188 119.699482) (xy 135.710498 119.81918) (xy 135.769463 119.929494) (xy 135.848815 120.026185) + (xy 135.945506 120.105537) (xy 136.017838 120.1442) (xy 130.881802 120.1442) (xy 129.465679 118.728078) (xy 129.422767 118.624479) + (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) (xy 128.92636 118.217089) (xy 128.76504 118.185) + (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) (xy 128.47418 117.955498) (xy 128.354482 117.919188) + (xy 128.23 117.906928) (xy 127.696267 117.906928) (xy 129.582564 116.020632) + ) + ) + (filled_polygon + (pts + (xy 150.544189 115.771742) (xy 150.462011 115.925488) (xy 150.428813 116.034924) (xy 150.417814 116.071185) (xy 150.411405 116.092311) + (xy 150.3986 116.222324) (xy 150.3986 116.222331) (xy 150.395922 116.249528) (xy 150.2836 116.249528) (xy 150.159118 116.261788) + (xy 150.03942 116.298098) (xy 149.929106 116.357063) (xy 149.832415 116.436415) (xy 149.753063 116.533106) (xy 149.694098 116.64342) + (xy 149.657788 116.763118) (xy 149.645528 116.8876) (xy 149.645528 117.8876) (xy 149.657788 118.012082) (xy 149.694098 118.13178) + (xy 149.753063 118.242094) (xy 149.769892 118.2626) (xy 149.753063 118.283106) (xy 149.694098 118.39342) (xy 149.690256 118.406086) + (xy 149.630287 118.424277) (xy 149.604649 118.432054) (xy 149.472619 118.502626) (xy 149.426258 118.540674) (xy 149.356895 118.597599) + (xy 149.333097 118.626597) (xy 148.518851 119.440844) (xy 148.5186 119.42335) (xy 148.35985 119.2646) (xy 147.0106 119.2646) + (xy 147.0106 119.2846) (xy 146.7566 119.2846) (xy 146.7566 119.2646) (xy 146.7366 119.2646) (xy 146.7366 119.0106) + (xy 146.7566 119.0106) (xy 146.7566 118.9906) (xy 147.0106 118.9906) (xy 147.0106 119.0106) (xy 148.35985 119.0106) + (xy 148.5186 118.85185) (xy 148.521672 118.6376) (xy 148.509412 118.513118) (xy 148.473102 118.39342) (xy 148.414137 118.283106) + (xy 148.397308 118.2626) (xy 148.414137 118.242094) (xy 148.473102 118.13178) (xy 148.509412 118.012082) (xy 148.521672 117.8876) + (xy 148.521672 116.8876) (xy 148.509412 116.763118) (xy 148.473102 116.64342) (xy 148.414137 116.533106) (xy 148.334785 116.436415) + (xy 148.238094 116.357063) (xy 148.12778 116.298098) (xy 148.008082 116.261788) (xy 147.8836 116.249528) (xy 145.8836 116.249528) + (xy 145.759118 116.261788) (xy 145.63942 116.298098) (xy 145.529106 116.357063) (xy 145.432415 116.436415) (xy 145.353063 116.533106) + (xy 145.294098 116.64342) (xy 145.291137 116.653181) (xy 145.195953 116.682054) (xy 145.063924 116.752626) (xy 144.948199 116.847599) + (xy 144.924396 116.876603) (xy 144.711798 117.089201) (xy 144.6828 117.112999) (xy 144.659002 117.141997) (xy 144.659001 117.141998) + (xy 144.587826 117.228724) (xy 144.549742 117.299974) (xy 144.517254 117.360753) (xy 144.500825 117.414913) (xy 144.434512 117.33411) + (xy 144.405509 117.310308) (xy 144.253079 117.157878) (xy 144.210167 117.054279) (xy 144.118787 116.917519) (xy 144.002481 116.801213) + (xy 143.865721 116.709833) (xy 143.71376 116.646889) (xy 143.55244 116.6148) (xy 143.38796 116.6148) (xy 143.304826 116.631337) + (xy 143.289502 116.58082) (xy 143.230537 116.470506) (xy 143.151185 116.373815) (xy 143.054494 116.294463) (xy 142.94418 116.235498) + (xy 142.824482 116.199188) (xy 142.7 116.186928) (xy 141.9604 116.186928) (xy 141.9604 115.984077) (xy 141.963835 115.9492) + (xy 141.950127 115.810016) (xy 141.938413 115.7714) (xy 150.444778 115.7714) (xy 150.4821 115.775076) (xy 150.519422 115.7714) + (xy 150.519433 115.7714) (xy 150.546671 115.768717) + ) + ) + (filled_polygon + (pts + (xy 180.127 119.048) (xy 180.147 119.048) (xy 180.147 119.302) (xy 180.127 119.302) (xy 180.127 119.322) + (xy 180.0588 119.322) (xy 180.0588 119.028) (xy 180.127 119.028) + ) + ) + (filled_polygon + (pts + (xy 187.386928 109.175) (xy 187.399188 109.299482) (xy 187.435498 109.41918) (xy 187.494463 109.529494) (xy 187.573815 109.626185) + (xy 187.670506 109.705537) (xy 187.740001 109.742683) (xy 187.740001 110.842668) (xy 187.736324 110.88) (xy 187.740001 110.917333) + (xy 187.747436 110.992815) (xy 187.750998 111.028985) (xy 187.794454 111.172246) (xy 187.865026 111.304276) (xy 187.911928 111.361426) + (xy 187.911928 113.08) (xy 187.924188 113.204482) (xy 187.960498 113.32418) (xy 188.019463 113.434494) (xy 188.098815 113.531185) + (xy 188.195506 113.610537) (xy 188.1962 113.610908) (xy 188.165 113.76776) (xy 188.165 113.93224) (xy 188.197089 114.09356) + (xy 188.260033 114.245521) (xy 188.351413 114.382281) (xy 188.467719 114.498587) (xy 188.604479 114.589967) (xy 188.75644 114.652911) + (xy 188.91776 114.685) (xy 189.08224 114.685) (xy 189.24356 114.652911) (xy 189.395521 114.589967) (xy 189.532281 114.498587) + (xy 189.648587 114.382281) (xy 189.739967 114.245521) (xy 189.802911 114.09356) (xy 189.835 113.93224) (xy 189.835 113.76776) + (xy 189.825116 113.718072) (xy 190.85 113.718072) (xy 190.974482 113.705812) (xy 191.09418 113.669502) (xy 191.204494 113.610537) + (xy 191.301185 113.531185) (xy 191.328525 113.497872) (xy 191.529017 113.698364) (xy 191.878698 113.932013) (xy 192.094302 114.021319) + (xy 192.025 114.369721) (xy 192.025 114.790279) (xy 192.107047 115.202756) (xy 192.267988 115.591302) (xy 192.340083 115.6992) + (xy 185.140924 115.6992) (xy 185.103601 115.695524) (xy 185.066278 115.6992) (xy 185.066269 115.6992) (xy 184.954616 115.710197) + (xy 184.818894 115.751367) (xy 184.811355 115.753654) (xy 184.679325 115.824226) (xy 184.595685 115.892868) (xy 184.563601 115.919199) + (xy 184.539803 115.948197) (xy 183.61 116.878001) (xy 183.61 116.445521) (xy 183.613676 116.408198) (xy 183.61 116.370875) + (xy 183.61 116.370865) (xy 183.599003 116.259212) (xy 183.555546 116.115951) (xy 183.54291 116.092311) (xy 183.484974 115.983921) + (xy 183.413799 115.897195) (xy 183.390001 115.868197) (xy 183.361003 115.844399) (xy 182.223203 114.7066) (xy 183.683 113.246804) + (xy 183.683004 113.246799) (xy 184.036768 112.893036) (xy 184.101251 112.957519) (xy 184.238011 113.048899) (xy 184.389972 113.111843) + (xy 184.551292 113.143932) (xy 184.715772 113.143932) (xy 184.877092 113.111843) (xy 185.029053 113.048899) (xy 185.165813 112.957519) + (xy 185.282119 112.841213) (xy 185.373499 112.704453) (xy 185.416411 112.600855) (xy 186.411131 111.606136) (xy 186.41114 111.606125) + (xy 186.461007 111.556258) (xy 186.490011 111.532455) (xy 186.584984 111.41673) (xy 186.655556 111.284701) (xy 186.699013 111.14144) + (xy 186.71001 111.029787) (xy 186.713687 110.992454) (xy 186.71001 110.955121) (xy 186.71001 109.679789) (xy 187.386928 109.002871) + ) + ) + (filled_polygon + (pts + (xy 140.505154 115.2392) (xy 137.785277 115.2392) (xy 137.7504 115.235765) (xy 137.715523 115.2392) (xy 137.611216 115.249473) + (xy 137.47738 115.290072) (xy 137.354037 115.356) (xy 137.245925 115.444725) (xy 137.1572 115.552837) (xy 137.091272 115.67618) + (xy 137.050673 115.810016) (xy 137.036965 115.9492) (xy 137.040401 115.984087) (xy 137.040401 116.186928) (xy 136.3 116.186928) + (xy 136.175518 116.199188) (xy 136.05582 116.235498) (xy 135.945506 116.294463) (xy 135.848815 116.373815) (xy 135.769463 116.470506) + (xy 135.718954 116.565) (xy 135.51472 116.565) (xy 135.477397 116.561324) (xy 135.440074 116.565) (xy 135.440065 116.565) + (xy 135.328412 116.575997) (xy 135.185151 116.619454) (xy 135.119922 116.65432) (xy 134.1184 115.652799) (xy 135.499679 115.652799) + (xy 135.537001 115.656475) (xy 135.574323 115.652799) (xy 135.574334 115.652799) (xy 135.685987 115.641802) (xy 135.829248 115.598345) + (xy 135.961277 115.527773) (xy 136.077002 115.4328) (xy 136.100804 115.403797) (xy 136.292001 115.2126) (xy 140.499863 115.2126) + ) + ) + (filled_polygon + (pts + (xy 179.275 107.029721) (xy 179.275 107.450279) (xy 179.344302 107.798682) (xy 179.128698 107.887988) (xy 178.779017 108.121637) + (xy 178.481637 108.419017) (xy 178.247988 108.768698) (xy 178.087047 109.157244) (xy 178.005 109.569721) (xy 178.005 109.990279) + (xy 178.087047 110.402756) (xy 178.247988 110.791302) (xy 178.481637 111.140983) (xy 178.779017 111.438363) (xy 179.128698 111.672012) + (xy 179.517244 111.832953) (xy 179.929721 111.915) (xy 180.350279 111.915) (xy 180.762756 111.832953) (xy 181.151302 111.672012) + (xy 181.265104 111.595972) (xy 181.34648 111.677348) (xy 181.48324 111.768728) (xy 181.635201 111.831672) (xy 181.796521 111.863761) + (xy 181.961001 111.863761) (xy 182.122321 111.831672) (xy 182.274282 111.768728) (xy 182.277831 111.766356) (xy 182.383486 111.734307) + (xy 182.515515 111.663735) (xy 182.63124 111.568762) (xy 182.655043 111.539758) (xy 182.736729 111.458072) (xy 183.322129 111.458072) + (xy 182.608203 112.171998) (xy 182.608198 112.172002) (xy 180.833601 113.9466) (xy 176.364325 113.9466) (xy 176.327 113.942924) + (xy 176.289675 113.9466) (xy 176.289667 113.9466) (xy 176.178014 113.957597) (xy 176.034753 114.001054) (xy 175.902724 114.071626) + (xy 175.786999 114.166599) (xy 175.763201 114.195597) (xy 174.908077 115.050721) (xy 174.804479 115.093633) (xy 174.667719 115.185013) + (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) (xy 174.365 115.75136) (xy 174.365 115.91584) + (xy 174.397089 116.07716) (xy 174.460033 116.229121) (xy 174.498658 116.286928) (xy 174.4 116.286928) (xy 174.275518 116.299188) + (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.869463 116.570506) (xy 173.832852 116.639) + (xy 173.128957 116.639) (xy 173.073724 116.616122) (xy 172.423536 115.965934) (xy 172.501281 115.913987) (xy 172.617587 115.797681) + (xy 172.708967 115.660921) (xy 172.751879 115.557322) (xy 174.290992 114.01821) (xy 174.31999 113.994412) (xy 174.414963 113.878687) + (xy 174.485535 113.746658) (xy 174.528992 113.603397) (xy 174.539989 113.491744) (xy 174.539989 113.491735) (xy 174.543665 113.454412) + (xy 174.539989 113.417089) (xy 174.539989 111.972157) (xy 174.5829 111.86856) (xy 174.584169 111.862178) (xy 174.849721 111.915) + (xy 175.270279 111.915) (xy 175.682756 111.832953) (xy 176.071302 111.672012) (xy 176.420983 111.438363) (xy 176.718363 111.140983) + (xy 176.952012 110.791302) (xy 177.112953 110.402756) (xy 177.195 109.990279) (xy 177.195 109.569721) (xy 177.112953 109.157244) + (xy 176.952012 108.768698) (xy 176.718363 108.419017) (xy 176.420983 108.121637) (xy 176.071302 107.887988) (xy 175.855698 107.798682) + (xy 175.925 107.45028) (xy 175.925 107.029722) (xy 175.873463 106.770627) (xy 175.888412 106.785576) (xy 176.328175 107.079417) + (xy 176.816814 107.281817) (xy 177.335551 107.385) (xy 177.864449 107.385) (xy 178.383186 107.281817) (xy 178.871825 107.079417) + (xy 179.311588 106.785576) (xy 179.326537 106.770627) + ) + ) + (filled_polygon + (pts + (xy 168.136928 104.575) (xy 168.149188 104.699482) (xy 168.185498 104.81918) (xy 168.244463 104.929494) (xy 168.323815 105.026185) + (xy 168.420506 105.105537) (xy 168.53082 105.164502) (xy 168.650518 105.200812) (xy 168.775 105.213072) (xy 169.46327 105.213072) + (xy 169.840001 105.589803) (xy 169.840001 105.641928) (xy 169.45 105.641928) (xy 169.325518 105.654188) (xy 169.20582 105.690498) + (xy 169.095506 105.749463) (xy 168.998815 105.828815) (xy 168.919463 105.925506) (xy 168.860498 106.03582) (xy 168.824188 106.155518) + (xy 168.811928 106.28) (xy 168.811928 108.28) (xy 168.824188 108.404482) (xy 168.860498 108.52418) (xy 168.919463 108.634494) + (xy 168.998815 108.731185) (xy 169.095506 108.810537) (xy 169.0962 108.810908) (xy 169.065 108.96776) (xy 169.065 109.13224) + (xy 169.097089 109.29356) (xy 169.160033 109.445521) (xy 169.251413 109.582281) (xy 169.367719 109.698587) (xy 169.504479 109.789967) + (xy 169.65644 109.852911) (xy 169.81776 109.885) (xy 169.98224 109.885) (xy 170.14356 109.852911) (xy 170.295521 109.789967) + (xy 170.432281 109.698587) (xy 170.548587 109.582281) (xy 170.639967 109.445521) (xy 170.702911 109.29356) (xy 170.735 109.13224) + (xy 170.735 108.96776) (xy 170.725116 108.918072) (xy 171.75 108.918072) (xy 171.874482 108.905812) (xy 171.99418 108.869502) + (xy 172.104494 108.810537) (xy 172.201185 108.731185) (xy 172.228525 108.697872) (xy 172.429017 108.898364) (xy 172.778698 109.132013) + (xy 172.994302 109.221319) (xy 172.925 109.569721) (xy 172.925 109.990279) (xy 173.007047 110.402756) (xy 173.167988 110.791302) + (xy 173.278104 110.956103) (xy 173.247708 110.976413) (xy 173.131402 111.092719) (xy 173.040022 111.229479) (xy 172.977078 111.38144) + (xy 172.944989 111.54276) (xy 172.944989 111.70724) (xy 172.977078 111.86856) (xy 173.019989 111.972157) (xy 173.01999 113.139608) + (xy 171.677078 114.482521) (xy 171.573479 114.525433) (xy 171.436719 114.616813) (xy 171.320413 114.733119) (xy 171.268466 114.810864) + (xy 168.593614 112.136013) (xy 168.606311 112.10536) (xy 168.6384 111.94404) (xy 168.6384 111.77956) (xy 168.606311 111.61824) + (xy 168.543367 111.466279) (xy 168.451987 111.329519) (xy 168.335681 111.213213) (xy 168.198921 111.121833) (xy 168.04696 111.058889) + (xy 167.88564 111.0268) (xy 167.76 111.0268) (xy 167.76 104.779799) (xy 168.136928 104.402872) + ) + ) + (filled_polygon + (pts + (xy 210.578411 46.740313) (xy 210.660589 46.894059) (xy 210.713887 46.959002) (xy 210.771183 47.028817) (xy 210.865445 47.106176) + (xy 210.905942 47.139411) (xy 211.059688 47.221589) (xy 211.168094 47.254474) (xy 211.206426 47.266102) (xy 211.260033 47.395521) + (xy 211.351413 47.532281) (xy 211.467719 47.648587) (xy 211.604479 47.739967) (xy 211.75644 47.802911) (xy 211.91776 47.835) + (xy 211.960199 47.835) (xy 211.961928 47.836729) (xy 211.961928 48.275) (xy 211.974188 48.399482) (xy 212.010498 48.51918) + (xy 212.058312 48.608633) (xy 211.997089 48.75644) (xy 211.965 48.91776) (xy 211.965 49.08224) (xy 211.997089 49.24356) + (xy 212.060033 49.395521) (xy 212.151413 49.532281) (xy 212.267719 49.648587) (xy 212.404479 49.739967) (xy 212.55644 49.802911) + (xy 212.71776 49.835) (xy 212.88224 49.835) (xy 213.04356 49.802911) (xy 213.195521 49.739967) (xy 213.332281 49.648587) + (xy 213.391195 49.589673) (xy 213.445525 49.655875) (xy 213.524337 49.720554) (xy 213.553637 49.7446) (xy 213.67698 49.810528) + (xy 213.810816 49.851127) (xy 213.95 49.864835) (xy 213.984877 49.8614) (xy 214.912478 49.8614) (xy 214.528175 50.020583) + (xy 214.088412 50.314424) (xy 213.714424 50.688412) (xy 213.635 50.807278) (xy 213.635 50.71776) (xy 213.602911 50.55644) + (xy 213.539967 50.404479) (xy 213.448587 50.267719) (xy 213.332281 50.151413) (xy 213.195521 50.060033) (xy 213.04356 49.997089) + (xy 212.88224 49.965) (xy 212.71776 49.965) (xy 212.55644 49.997089) (xy 212.404479 50.060033) (xy 212.267719 50.151413) + (xy 212.151413 50.267719) (xy 212.060033 50.404479) (xy 211.997089 50.55644) (xy 211.965 50.71776) (xy 211.965 50.88224) + (xy 211.997089 51.04356) (xy 212.017836 51.093649) (xy 212.003411 51.08401) (xy 211.733158 50.972068) (xy 211.44626 50.915) + (xy 211.276697 50.915) (xy 211.182327 50.875911) (xy 210.876109 50.815) (xy 210.563891 50.815) (xy 210.257673 50.875911) + (xy 209.969221 50.995391) (xy 209.709621 51.16885) (xy 209.48885 51.389621) (xy 209.315391 51.649221) (xy 209.195911 51.937673) + (xy 209.135 52.243891) (xy 209.135 52.556109) (xy 209.195911 52.862327) (xy 209.315391 53.150779) (xy 209.443113 53.341928) + (xy 208.512166 53.341928) (xy 208.552911 53.24356) (xy 208.585 53.08224) (xy 208.585 52.976018) (xy 208.676185 52.901185) + (xy 208.755537 52.804494) (xy 208.814502 52.69418) (xy 208.850812 52.574482) (xy 208.863072 52.45) (xy 208.863072 51.15) + (xy 208.850812 51.025518) (xy 208.814502 50.90582) (xy 208.755537 50.795506) (xy 208.676185 50.698815) (xy 208.579494 50.619463) + (xy 208.46918 50.560498) (xy 208.349482 50.524188) (xy 208.225 50.511928) (xy 207.275 50.511928) (xy 207.150518 50.524188) + (xy 207.03082 50.560498) (xy 206.920506 50.619463) (xy 206.823815 50.698815) (xy 206.744463 50.795506) (xy 206.685498 50.90582) + (xy 206.649188 51.025518) (xy 206.636928 51.15) (xy 206.636928 52.45) (xy 206.649188 52.574482) (xy 206.685498 52.69418) + (xy 206.744463 52.804494) (xy 206.823815 52.901185) (xy 206.915 52.976018) (xy 206.915 53.08224) (xy 206.947089 53.24356) + (xy 206.990001 53.347158) (xy 206.99 53.992677) (xy 206.986324 54.03) (xy 206.99 54.067322) (xy 206.99 54.067332) + (xy 207.000997 54.178985) (xy 207.011928 54.21502) (xy 207.011928 55.98) (xy 207.024188 56.104482) (xy 207.060498 56.22418) + (xy 207.119463 56.334494) (xy 207.198815 56.431185) (xy 207.295506 56.510537) (xy 207.40582 56.569502) (xy 207.525518 56.605812) + (xy 207.65 56.618072) (xy 208.062565 56.618072) (xy 208.065026 56.622676) (xy 208.134558 56.7074) (xy 208.16 56.738401) + (xy 208.188998 56.762199) (xy 212.229015 60.802218) (xy 212.252809 60.831211) (xy 212.281802 60.855005) (xy 212.281806 60.855009) + (xy 212.350255 60.911183) (xy 212.368534 60.926184) (xy 212.500563 60.996756) (xy 212.643824 61.040213) (xy 212.755477 61.05121) + (xy 212.755486 61.05121) (xy 212.792809 61.054886) (xy 212.830132 61.05121) (xy 214.308243 61.05121) (xy 214.41184 61.094121) + (xy 214.57316 61.12621) (xy 214.73764 61.12621) (xy 214.89896 61.094121) (xy 215.050921 61.031177) (xy 215.187681 60.939797) + (xy 215.303987 60.823491) (xy 215.328801 60.786354) (xy 215.328801 61.251468) (xy 215.325124 61.2888) (xy 215.328801 61.326133) + (xy 215.339798 61.437786) (xy 215.346901 61.461201) (xy 215.383254 61.581046) (xy 215.453826 61.713076) (xy 215.512849 61.784995) + (xy 215.5488 61.828801) (xy 215.577798 61.852599) (xy 216.541199 62.816) (xy 213.984877 62.816) (xy 213.95 62.812565) + (xy 213.915123 62.816) (xy 213.810816 62.826273) (xy 213.67698 62.866872) (xy 213.553637 62.9328) (xy 213.445525 63.021525) + (xy 213.3568 63.129637) (xy 213.290872 63.25298) (xy 213.250273 63.386816) (xy 213.236565 63.526) (xy 213.240001 63.560887) + (xy 213.240001 63.786928) (xy 212.5 63.786928) (xy 212.375518 63.799188) (xy 212.25582 63.835498) (xy 212.145506 63.894463) + (xy 212.048815 63.973815) (xy 211.969463 64.070506) (xy 211.910498 64.18082) (xy 211.874188 64.300518) (xy 211.861928 64.425) + (xy 211.861928 64.636493) (xy 211.283422 65.215) (xy 209.893469 65.215) (xy 209.85 65.210719) (xy 209.806531 65.215) + (xy 209.806523 65.215) (xy 209.67651 65.227805) (xy 209.509687 65.278411) (xy 209.355941 65.360589) (xy 209.221183 65.471183) + (xy 209.193468 65.504954) (xy 208.908422 65.79) (xy 208.863072 65.79) (xy 208.863072 64.85) (xy 208.850812 64.725518) + (xy 208.814502 64.60582) (xy 208.755537 64.495506) (xy 208.676185 64.398815) (xy 208.579494 64.319463) (xy 208.46918 64.260498) + (xy 208.349482 64.224188) (xy 208.225 64.211928) (xy 207.275 64.211928) (xy 207.246148 64.21477) (xy 207.413928 64.145273) + (xy 207.902826 63.818601) (xy 208.318601 63.402826) (xy 208.645273 62.913928) (xy 208.870288 62.370692) (xy 208.985 61.793997) + (xy 208.985 61.206003) (xy 208.870288 60.629308) (xy 208.645273 60.086072) (xy 208.318601 59.597174) (xy 207.902826 59.181399) + (xy 207.413928 58.854727) (xy 206.870692 58.629712) (xy 206.293997 58.515) (xy 205.706003 58.515) (xy 205.129308 58.629712) + (xy 204.586072 58.854727) (xy 204.097174 59.181399) (xy 203.681399 59.597174) (xy 203.354727 60.086072) (xy 203.129712 60.629308) + (xy 203.015 61.206003) (xy 203.015 61.793997) (xy 203.129712 62.370692) (xy 203.354727 62.913928) (xy 203.681399 63.402826) + (xy 204.097174 63.818601) (xy 204.586072 64.145273) (xy 205.129308 64.370288) (xy 205.706003 64.485) (xy 206.293997 64.485) + (xy 206.854699 64.373469) (xy 206.823815 64.398815) (xy 206.744463 64.495506) (xy 206.685498 64.60582) (xy 206.662691 64.681003) + (xy 206.58224 64.665) (xy 206.41776 64.665) (xy 206.25644 64.697089) (xy 206.152843 64.74) (xy 204.412333 64.74) + (xy 204.375 64.736323) (xy 204.337667 64.74) (xy 204.226014 64.750997) (xy 204.082753 64.794454) (xy 203.950724 64.865026) + (xy 203.834999 64.959999) (xy 203.811201 64.988997) (xy 202.273078 66.527121) (xy 202.169479 66.570033) (xy 202.032719 66.661413) + (xy 201.916413 66.777719) (xy 201.825033 66.914479) (xy 201.762089 67.06644) (xy 201.73 67.22776) (xy 201.73 67.39224) + (xy 201.762089 67.55356) (xy 201.825033 67.705521) (xy 201.916413 67.842281) (xy 202.032719 67.958587) (xy 202.169479 68.049967) + (xy 202.32144 68.112911) (xy 202.48276 68.145) (xy 202.64724 68.145) (xy 202.80856 68.112911) (xy 202.960521 68.049967) + (xy 203.097281 67.958587) (xy 203.213587 67.842281) (xy 203.304967 67.705521) (xy 203.347879 67.601922) (xy 204.689802 66.26) + (xy 205.393332 66.26) (xy 205.353411 66.334687) (xy 205.302805 66.50151) (xy 205.285718 66.675) (xy 205.302805 66.84849) + (xy 205.353411 67.015313) (xy 205.435589 67.169059) (xy 205.546183 67.303817) (xy 205.680941 67.414411) (xy 205.834687 67.496589) + (xy 206.00151 67.547195) (xy 206.131523 67.56) (xy 209.231531 67.56) (xy 209.275 67.564281) (xy 209.318469 67.56) + (xy 209.318477 67.56) (xy 209.44849 67.547195) (xy 209.615313 67.496589) (xy 209.769059 67.414411) (xy 209.903817 67.303817) + (xy 209.931534 67.270044) (xy 210.125185 67.076393) (xy 210.148491 67.19356) (xy 210.211435 67.345521) (xy 210.302815 67.482281) + (xy 210.419121 67.598587) (xy 210.555881 67.689967) (xy 210.707842 67.752911) (xy 210.869162 67.785) (xy 211.033642 67.785) + (xy 211.194962 67.752911) (xy 211.346923 67.689967) (xy 211.483683 67.598587) (xy 211.599989 67.482281) (xy 211.631581 67.435) + (xy 211.918954 67.435) (xy 211.969463 67.529494) (xy 212.048815 67.626185) (xy 212.145506 67.705537) (xy 212.25582 67.764502) + (xy 212.375518 67.800812) (xy 212.5 67.813072) (xy 213.24 67.813072) (xy 213.24 67.991123) (xy 213.236565 68.026) + (xy 213.250273 68.165184) (xy 213.290872 68.29902) (xy 213.3568 68.422363) (xy 213.445525 68.530475) (xy 213.553637 68.6192) + (xy 213.67698 68.685128) (xy 213.810816 68.725727) (xy 213.95 68.739435) (xy 213.984877 68.736) (xy 214.8738 68.736) + (xy 214.428175 68.920583) (xy 213.988412 69.214424) (xy 213.614424 69.588412) (xy 213.320583 70.028175) (xy 213.118183 70.516814) + (xy 213.015 71.035551) (xy 213.015 71.564449) (xy 213.118183 72.083186) (xy 213.123749 72.096623) (xy 212.901302 71.947989) + (xy 212.592012 71.819877) (xy 212.627932 71.733158) (xy 212.685 71.44626) (xy 212.685 71.15374) (xy 212.627932 70.866842) + (xy 212.51599 70.596589) (xy 212.353475 70.353368) (xy 212.146632 70.146525) (xy 211.903411 69.98401) (xy 211.633158 69.872068) + (xy 211.34626 69.815) (xy 211.176697 69.815) (xy 211.082327 69.775911) (xy 210.776109 69.715) (xy 210.463891 69.715) + (xy 210.157673 69.775911) (xy 209.869221 69.895391) (xy 209.609621 70.06885) (xy 209.38885 70.289621) (xy 209.215391 70.549221) + (xy 209.095911 70.837673) (xy 209.035 71.143891) (xy 209.035 71.456109) (xy 209.036015 71.461214) (xy 208.51 70.935199) + (xy 208.51 70.847157) (xy 208.552911 70.74356) (xy 208.585 70.58224) (xy 208.585 70.41776) (xy 208.552911 70.25644) + (xy 208.548945 70.246866) (xy 208.579494 70.230537) (xy 208.676185 70.151185) (xy 208.755537 70.054494) (xy 208.814502 69.94418) + (xy 208.850812 69.824482) (xy 208.863072 69.7) (xy 208.863072 68.4) (xy 208.850812 68.275518) (xy 208.814502 68.15582) + (xy 208.755537 68.045506) (xy 208.676185 67.948815) (xy 208.579494 67.869463) (xy 208.46918 67.810498) (xy 208.349482 67.774188) + (xy 208.225 67.761928) (xy 207.275 67.761928) (xy 207.150518 67.774188) (xy 207.03082 67.810498) (xy 206.920506 67.869463) + (xy 206.823815 67.948815) (xy 206.744463 68.045506) (xy 206.685498 68.15582) (xy 206.649188 68.275518) (xy 206.636928 68.4) + (xy 206.636928 69.7) (xy 206.649188 69.824482) (xy 206.685498 69.94418) (xy 206.744463 70.054494) (xy 206.823815 70.151185) + (xy 206.920506 70.230537) (xy 206.951055 70.246866) (xy 206.947089 70.25644) (xy 206.915 70.41776) (xy 206.915 70.58224) + (xy 206.947089 70.74356) (xy 206.99 70.847157) (xy 206.99 71.212678) (xy 206.986324 71.25) (xy 206.99 71.287322) + (xy 206.99 71.287332) (xy 207.000997 71.398985) (xy 207.033156 71.505) (xy 207.044454 71.542246) (xy 207.115026 71.674276) + (xy 207.140241 71.705) (xy 207.209999 71.790001) (xy 207.239002 71.813804) (xy 207.667127 72.241928) (xy 207.55 72.241928) + (xy 207.425518 72.254188) (xy 207.30582 72.290498) (xy 207.195506 72.349463) (xy 207.098815 72.428815) (xy 207.019463 72.525506) + (xy 206.960498 72.63582) (xy 206.924188 72.755518) (xy 206.911928 72.88) (xy 206.911928 74.88) (xy 206.924188 75.004482) + (xy 206.960498 75.12418) (xy 207.019463 75.234494) (xy 207.098815 75.331185) (xy 207.195506 75.410537) (xy 207.30582 75.469502) + (xy 207.425518 75.505812) (xy 207.55 75.518072) (xy 208.045674 75.518072) (xy 208.065026 75.554276) (xy 208.136201 75.641002) + (xy 208.16 75.670001) (xy 208.188998 75.693799) (xy 210.131788 77.636589) (xy 212.08119 79.585992) (xy 212.104988 79.61499) + (xy 212.133986 79.638788) (xy 212.220712 79.709963) (xy 212.339743 79.773587) (xy 212.352742 79.780535) (xy 212.496003 79.823992) + (xy 212.607656 79.834989) (xy 212.607666 79.834989) (xy 212.644989 79.838665) (xy 212.682312 79.834989) (xy 215.679843 79.834989) + (xy 215.78344 79.8779) (xy 215.94476 79.909989) (xy 216.10924 79.909989) (xy 216.27056 79.8779) (xy 216.422521 79.814956) + (xy 216.559281 79.723576) (xy 216.616532 79.666325) (xy 217.340001 80.389794) (xy 217.340001 82.0795) (xy 213.984877 82.0795) + (xy 213.95 82.076065) (xy 213.915123 82.0795) (xy 213.810816 82.089773) (xy 213.67698 82.130372) (xy 213.553637 82.1963) + (xy 213.445525 82.285025) (xy 213.3568 82.393137) (xy 213.290872 82.51648) (xy 213.250273 82.650316) (xy 213.236565 82.7895) + (xy 213.240001 82.824387) (xy 213.240001 82.986928) (xy 212.5 82.986928) (xy 212.375518 82.999188) (xy 212.25582 83.035498) + (xy 212.145506 83.094463) (xy 212.048815 83.173815) (xy 211.994499 83.24) (xy 211.956467 83.24) (xy 211.912998 83.235719) + (xy 211.869529 83.24) (xy 211.869521 83.24) (xy 211.739508 83.252805) (xy 211.572685 83.303411) (xy 211.464336 83.361324) + (xy 211.418939 83.385589) (xy 211.317951 83.468468) (xy 211.317949 83.46847) (xy 211.284181 83.496183) (xy 211.256468 83.529951) + (xy 210.279956 84.506464) (xy 210.246183 84.534181) (xy 210.135589 84.66894) (xy 210.053411 84.822686) (xy 210.02457 84.91776) + (xy 210.002805 84.989508) (xy 210.00172 85.000521) (xy 209.99 85.119522) (xy 209.99 85.119529) (xy 209.985719 85.162998) + (xy 209.99 85.206467) (xy 209.99 85.918477) (xy 210.002805 86.04849) (xy 210.053412 86.215313) (xy 210.13559 86.369059) + (xy 210.246184 86.503817) (xy 210.380942 86.614411) (xy 210.534688 86.696589) (xy 210.701511 86.747195) (xy 210.875 86.764282) + (xy 211.04849 86.747195) (xy 211.215313 86.696589) (xy 211.369059 86.614411) (xy 211.503817 86.503817) (xy 211.614411 86.369059) + (xy 211.696589 86.215313) (xy 211.747195 86.04849) (xy 211.76 85.918477) (xy 211.76 85.834801) (xy 211.861928 85.936729) + (xy 211.861928 86.375) (xy 211.874188 86.499482) (xy 211.910498 86.61918) (xy 211.969463 86.729494) (xy 212.048815 86.826185) + (xy 212.145506 86.905537) (xy 212.25582 86.964502) (xy 212.375518 87.000812) (xy 212.5 87.013072) (xy 212.54 87.013072) + (xy 212.540001 89.854556) (xy 212.51599 89.796589) (xy 212.353475 89.553368) (xy 212.146632 89.346525) (xy 211.903411 89.18401) + (xy 211.633158 89.072068) (xy 211.34626 89.015) (xy 211.176697 89.015) (xy 211.082327 88.975911) (xy 210.776109 88.915) + (xy 210.463891 88.915) (xy 210.157673 88.975911) (xy 209.869221 89.095391) (xy 209.609621 89.26885) (xy 209.38885 89.489621) + (xy 209.215391 89.749221) (xy 209.095911 90.037673) (xy 209.035 90.343891) (xy 209.035 90.656109) (xy 209.095911 90.962327) + (xy 209.137476 91.062674) (xy 208.51 90.435199) (xy 208.51 89.597157) (xy 208.552911 89.49356) (xy 208.585 89.33224) + (xy 208.585 89.226018) (xy 208.676185 89.151185) (xy 208.755537 89.054494) (xy 208.814502 88.94418) (xy 208.850812 88.824482) + (xy 208.863072 88.7) (xy 208.863072 87.4) (xy 208.850812 87.275518) (xy 208.814502 87.15582) (xy 208.755537 87.045506) + (xy 208.676185 86.948815) (xy 208.579494 86.869463) (xy 208.46918 86.810498) (xy 208.349482 86.774188) (xy 208.225 86.761928) + (xy 207.275 86.761928) (xy 207.150518 86.774188) (xy 207.03082 86.810498) (xy 206.920506 86.869463) (xy 206.823815 86.948815) + (xy 206.744463 87.045506) (xy 206.685498 87.15582) (xy 206.649188 87.275518) (xy 206.636928 87.4) (xy 206.636928 88.7) + (xy 206.649188 88.824482) (xy 206.685498 88.94418) (xy 206.744463 89.054494) (xy 206.823815 89.151185) (xy 206.915 89.226018) + (xy 206.915 89.33224) (xy 206.947089 89.49356) (xy 206.990001 89.597159) (xy 206.99 90.712677) (xy 206.986324 90.75) + (xy 206.99 90.787322) (xy 206.99 90.787332) (xy 207.000997 90.898985) (xy 207.035354 91.012246) (xy 207.044454 91.042246) + (xy 207.115026 91.174276) (xy 207.150679 91.217719) (xy 207.209999 91.290001) (xy 207.239002 91.313804) (xy 207.390124 91.464925) + (xy 207.30582 91.490498) (xy 207.195506 91.549463) (xy 207.098815 91.628815) (xy 207.019463 91.725506) (xy 206.960498 91.83582) + (xy 206.924188 91.955518) (xy 206.911928 92.08) (xy 206.911928 94.08) (xy 206.924188 94.204482) (xy 206.960498 94.32418) + (xy 207.019463 94.434494) (xy 207.098815 94.531185) (xy 207.195506 94.610537) (xy 207.30582 94.669502) (xy 207.425518 94.705812) + (xy 207.55 94.718072) (xy 207.940001 94.718072) (xy 207.94 96.412677) (xy 207.936324 96.45) (xy 207.94 96.487322) + (xy 207.94 96.487332) (xy 207.950997 96.598985) (xy 207.992136 96.734603) (xy 207.994454 96.742246) (xy 208.065026 96.874276) + (xy 208.095014 96.910816) (xy 208.159999 96.990001) (xy 208.189002 97.013804) (xy 208.967122 97.791923) (xy 209.010033 97.895521) + (xy 209.101413 98.032281) (xy 209.217719 98.148587) (xy 209.354479 98.239967) (xy 209.50644 98.302911) (xy 209.66776 98.335) + (xy 209.83224 98.335) (xy 209.99356 98.302911) (xy 210.145521 98.239967) (xy 210.282281 98.148587) (xy 210.398587 98.032281) + (xy 210.489967 97.895521) (xy 210.552911 97.74356) (xy 210.585 97.58224) (xy 210.585 97.41776) (xy 210.552911 97.25644) + (xy 210.489967 97.104479) (xy 210.398587 96.967719) (xy 210.282281 96.851413) (xy 210.145521 96.760033) (xy 210.041923 96.717122) + (xy 209.46 96.135199) (xy 209.46 94.718072) (xy 209.85 94.718072) (xy 209.974482 94.705812) (xy 210.09418 94.669502) + (xy 210.204494 94.610537) (xy 210.301185 94.531185) (xy 210.328525 94.497872) (xy 210.529017 94.698364) (xy 210.878698 94.932013) + (xy 211.094302 95.021319) (xy 211.025 95.369721) (xy 211.025 95.790279) (xy 211.107047 96.202756) (xy 211.267988 96.591302) + (xy 211.501637 96.940983) (xy 211.799017 97.238363) (xy 212.148698 97.472012) (xy 212.537244 97.632953) (xy 212.949721 97.715) + (xy 213.370279 97.715) (xy 213.782756 97.632953) (xy 214.171302 97.472012) (xy 214.520983 97.238363) (xy 214.818363 96.940983) + (xy 215.052012 96.591302) (xy 215.212953 96.202756) (xy 215.295 95.790279) (xy 215.295 95.369721) (xy 215.212953 94.957244) + (xy 215.052012 94.568698) (xy 214.818363 94.219017) (xy 214.520983 93.921637) (xy 214.171302 93.687988) (xy 213.955698 93.598682) + (xy 213.997704 93.387507) (xy 215.654999 95.044803) (xy 215.655 96.977667) (xy 215.651323 97.014999) (xy 215.655 97.052332) + (xy 215.664673 97.150537) (xy 215.665997 97.163984) (xy 215.709453 97.307245) (xy 215.780025 97.439275) (xy 215.845827 97.519454) + (xy 215.874999 97.555) (xy 215.903997 97.578798) (xy 219.09 100.764802) (xy 219.090001 102.003896) (xy 219.074482 101.999188) + (xy 218.95 101.986928) (xy 218.21 101.986928) (xy 218.21 101.760877) (xy 218.213435 101.726) (xy 218.199727 101.586816) + (xy 218.159128 101.45298) (xy 218.0932 101.329637) (xy 218.004475 101.221525) (xy 217.896363 101.1328) (xy 217.77302 101.066872) + (xy 217.639184 101.026273) (xy 217.534877 101.016) (xy 217.5 101.012565) (xy 217.465123 101.016) (xy 214.034877 101.016) + (xy 214 101.012565) (xy 213.965123 101.016) (xy 213.860816 101.026273) (xy 213.72698 101.066872) (xy 213.603637 101.1328) + (xy 213.495525 101.221525) (xy 213.4068 101.329637) (xy 213.340872 101.45298) (xy 213.300273 101.586816) (xy 213.286565 101.726) + (xy 213.290001 101.760887) (xy 213.290001 101.986928) (xy 212.55 101.986928) (xy 212.425518 101.999188) (xy 212.30582 102.035498) + (xy 212.195506 102.094463) (xy 212.098815 102.173815) (xy 212.044499 102.24) (xy 212.018466 102.24) (xy 211.974999 102.235719) + (xy 211.931533 102.24) (xy 211.931523 102.24) (xy 211.80151 102.252805) (xy 211.634687 102.303411) (xy 211.480941 102.385589) + (xy 211.346183 102.496183) (xy 211.318466 102.529956) (xy 211.004956 102.843466) (xy 210.971183 102.871183) (xy 210.860589 103.005942) + (xy 210.778411 103.159688) (xy 210.75498 103.236928) (xy 210.728483 103.324277) (xy 210.727805 103.326511) (xy 210.715 103.456524) + (xy 210.715 103.456531) (xy 210.710719 103.5) (xy 210.715 103.54347) (xy 210.715001 104.806521) (xy 210.710719 104.85) + (xy 210.727805 105.02349) (xy 210.778412 105.190313) (xy 210.86059 105.344059) (xy 210.943468 105.445046) (xy 210.943471 105.445049) + (xy 210.971184 105.478817) (xy 211.004952 105.50653) (xy 211.029954 105.531532) (xy 211.119872 105.605326) (xy 209.313072 107.412126) + (xy 209.313072 106.3) (xy 209.300812 106.175518) (xy 209.264502 106.05582) (xy 209.205537 105.945506) (xy 209.126185 105.848815) + (xy 209.029494 105.769463) (xy 208.91918 105.710498) (xy 208.799482 105.674188) (xy 208.675 105.661928) (xy 207.725 105.661928) + (xy 207.600518 105.674188) (xy 207.48082 105.710498) (xy 207.370506 105.769463) (xy 207.273815 105.848815) (xy 207.194463 105.945506) + (xy 207.135498 106.05582) (xy 207.099188 106.175518) (xy 207.086928 106.3) (xy 207.086928 106.943857) (xy 207.086323 106.95) + (xy 207.086928 106.956143) (xy 207.086928 107.6) (xy 207.099188 107.724482) (xy 207.135498 107.84418) (xy 207.194463 107.954494) + (xy 207.240001 108.009982) (xy 207.240001 108.252841) (xy 207.197089 108.35644) (xy 207.165 108.51776) (xy 207.165 108.68224) + (xy 207.197089 108.84356) (xy 207.260033 108.995521) (xy 207.351413 109.132281) (xy 207.467719 109.248587) (xy 207.47305 109.252149) + (xy 205.991003 110.734196) (xy 205.961999 110.757999) (xy 205.911923 110.819017) (xy 205.867026 110.873724) (xy 205.812503 110.975729) + (xy 205.796454 111.005754) (xy 205.752997 111.149015) (xy 205.742 111.260668) (xy 205.742 111.260678) (xy 205.738324 111.298) + (xy 205.742 111.335323) (xy 205.742001 113.032697) (xy 204.188072 114.586627) (xy 204.188072 113.901426) (xy 204.234974 113.844276) + (xy 204.305546 113.712247) (xy 204.349003 113.568986) (xy 204.36 113.457333) (xy 204.36 113.457324) (xy 204.363676 113.420001) + (xy 204.36 113.382678) (xy 204.36 110.347157) (xy 204.402911 110.24356) (xy 204.435 110.08224) (xy 204.435 109.91776) + (xy 204.402911 109.75644) (xy 204.339967 109.604479) (xy 204.248587 109.467719) (xy 204.132281 109.351413) (xy 203.995521 109.260033) + (xy 203.84356 109.197089) (xy 203.68224 109.165) (xy 203.51776 109.165) (xy 203.35644 109.197089) (xy 203.33737 109.204988) + (xy 203.304089 109.037673) (xy 203.184609 108.749221) (xy 203.01115 108.489621) (xy 202.790379 108.26885) (xy 202.530779 108.095391) + (xy 202.242327 107.975911) (xy 201.936109 107.915) (xy 201.623891 107.915) (xy 201.317673 107.975911) (xy 201.223303 108.015) + (xy 201.05374 108.015) (xy 200.766842 108.072068) (xy 200.496589 108.18401) (xy 200.253368 108.346525) (xy 200.046525 108.553368) + (xy 199.88401 108.796589) (xy 199.772068 109.066842) (xy 199.715 109.35374) (xy 199.715 109.64626) (xy 199.772068 109.933158) + (xy 199.807988 110.019876) (xy 199.498698 110.147988) (xy 199.276252 110.296622) (xy 199.281817 110.283186) (xy 199.385 109.764449) + (xy 199.385 109.235551) (xy 199.281817 108.716814) (xy 199.079417 108.228175) (xy 198.798349 107.807527) (xy 198.898585 107.707291) + (xy 198.989965 107.570531) (xy 199.052909 107.41857) (xy 199.054612 107.41001) (xy 203.112668 107.41001) (xy 203.14999 107.413686) + (xy 203.187312 107.41001) (xy 203.187323 107.41001) (xy 203.298976 107.399013) (xy 203.442237 107.355556) (xy 203.574266 107.284984) + (xy 203.689991 107.190011) (xy 203.713794 107.161007) (xy 205.163799 105.711003) (xy 205.163803 105.710998) (xy 206.091924 104.782878) + (xy 206.195521 104.739967) (xy 206.332281 104.648587) (xy 206.448587 104.532281) (xy 206.539967 104.395521) (xy 206.602911 104.24356) + (xy 206.635 104.08224) (xy 206.635 103.995354) (xy 206.662478 104.013714) (xy 206.814439 104.076658) (xy 206.851901 104.08411) + (xy 206.892005 104.105546) (xy 207.035266 104.149003) (xy 207.09728 104.155111) (xy 207.099188 104.174482) (xy 207.135498 104.29418) + (xy 207.194463 104.404494) (xy 207.273815 104.501185) (xy 207.370506 104.580537) (xy 207.48082 104.639502) (xy 207.600518 104.675812) + (xy 207.725 104.688072) (xy 208.675 104.688072) (xy 208.799482 104.675812) (xy 208.91918 104.639502) (xy 209.029494 104.580537) + (xy 209.126185 104.501185) (xy 209.205537 104.404494) (xy 209.264502 104.29418) (xy 209.300812 104.174482) (xy 209.313072 104.05) + (xy 209.313072 102.75) (xy 209.300812 102.625518) (xy 209.264502 102.50582) (xy 209.205537 102.395506) (xy 209.126185 102.298815) + (xy 209.029494 102.219463) (xy 208.91918 102.160498) (xy 208.799482 102.124188) (xy 208.675 102.111928) (xy 208.109499 102.111928) + (xy 208.318601 101.902826) (xy 208.645273 101.413928) (xy 208.870288 100.870692) (xy 208.985 100.293997) (xy 208.985 99.706003) + (xy 208.870288 99.129308) (xy 208.645273 98.586072) (xy 208.318601 98.097174) (xy 207.902826 97.681399) (xy 207.413928 97.354727) + (xy 206.870692 97.129712) (xy 206.293997 97.015) (xy 205.706003 97.015) (xy 205.129308 97.129712) (xy 204.586072 97.354727) + (xy 204.097174 97.681399) (xy 203.681399 98.097174) (xy 203.354727 98.586072) (xy 203.129712 99.129308) (xy 203.015 99.706003) + (xy 203.015 100.293997) (xy 203.118503 100.814343) (xy 203.071588 100.659685) (xy 202.98941 100.50594) (xy 202.878817 100.371181) + (xy 202.744058 100.260588) (xy 202.590313 100.17841) (xy 202.423489 100.127804) (xy 202.249999 100.110717) (xy 202.076509 100.127804) + (xy 201.909687 100.17841) (xy 201.755941 100.260588) (xy 201.689644 100.314997) (xy 194.800996 100.314997) (xy 194.757527 100.310716) + (xy 194.714058 100.314997) (xy 194.71405 100.314997) (xy 194.584037 100.327802) (xy 194.417214 100.378408) (xy 194.263468 100.460586) + (xy 194.12871 100.57118) (xy 194.100995 100.604951) (xy 193.704952 101.000994) (xy 193.671184 101.028707) (xy 193.643471 101.062475) + (xy 193.643468 101.062478) (xy 193.56059 101.163465) (xy 193.478412 101.317211) (xy 193.427805 101.484034) (xy 193.410719 101.657524) + (xy 193.415001 101.701003) (xy 193.415001 101.995299) (xy 193.375518 101.999188) (xy 193.25582 102.035498) (xy 193.145506 102.094463) + (xy 193.048815 102.173815) (xy 192.994499 102.24) (xy 192.868469 102.24) (xy 192.825 102.235719) (xy 192.781531 102.24) + (xy 192.781523 102.24) (xy 192.65151 102.252805) (xy 192.484687 102.303411) (xy 192.348887 102.375997) (xy 192.330941 102.385589) + (xy 192.229953 102.468468) (xy 192.229951 102.46847) (xy 192.196183 102.496183) (xy 192.16847 102.529951) (xy 191.504956 103.193466) + (xy 191.471183 103.221183) (xy 191.360589 103.355942) (xy 191.278411 103.509688) (xy 191.249656 103.604479) (xy 191.22851 103.674188) + (xy 191.227805 103.676511) (xy 191.215 103.806524) (xy 191.215 103.806531) (xy 191.210719 103.85) (xy 191.215 103.893469) + (xy 191.215 104.043477) (xy 191.227805 104.17349) (xy 191.278411 104.340313) (xy 191.360589 104.494059) (xy 191.471183 104.628817) + (xy 191.605942 104.739411) (xy 191.759688 104.821589) (xy 191.926511 104.872195) (xy 192.1 104.889282) (xy 192.27349 104.872195) + (xy 192.324625 104.856683) (xy 192.329081 104.871373) (xy 192.399653 105.003403) (xy 192.420494 105.028797) (xy 192.494626 105.119128) + (xy 192.52363 105.142931) (xy 192.741696 105.360997) (xy 192.765499 105.390001) (xy 192.872015 105.477416) (xy 192.874188 105.499482) + (xy 192.910498 105.61918) (xy 192.969463 105.729494) (xy 193.048815 105.826185) (xy 193.126586 105.89001) (xy 190.489812 105.89001) + (xy 190.170379 105.570577) (xy 190.127467 105.466979) (xy 190.036087 105.330219) (xy 189.919781 105.213913) (xy 189.783021 105.122533) + (xy 189.679423 105.079622) (xy 189.613072 105.01327) (xy 189.613072 104.325) (xy 189.600812 104.200518) (xy 189.564502 104.08082) + (xy 189.505537 103.970506) (xy 189.426185 103.873815) (xy 189.329494 103.794463) (xy 189.26 103.757317) (xy 189.26 97.037323) + (xy 189.263676 97) (xy 189.26 96.962677) (xy 189.26 96.962667) (xy 189.249003 96.851014) (xy 189.205546 96.707753) + (xy 189.195514 96.688985) (xy 189.134974 96.575723) (xy 189.063799 96.488997) (xy 189.040001 96.459999) (xy 189.011003 96.436201) + (xy 186.820707 94.245906) (xy 186.802911 94.15644) (xy 186.739967 94.004479) (xy 186.648587 93.867719) (xy 186.532281 93.751413) + (xy 186.395521 93.660033) (xy 186.24356 93.597089) (xy 186.234999 93.595386) (xy 186.234999 88.739802) (xy 187.386928 87.587875) + (xy 187.386928 87.65) (xy 187.399188 87.774482) (xy 187.435498 87.89418) (xy 187.494463 88.004494) (xy 187.573815 88.101185) + (xy 187.665 88.176018) (xy 187.665 88.33224) (xy 187.697089 88.49356) (xy 187.760033 88.645521) (xy 187.851413 88.782281) + (xy 187.967719 88.898587) (xy 188.104479 88.989967) (xy 188.25644 89.052911) (xy 188.41776 89.085) (xy 188.58224 89.085) + (xy 188.74356 89.052911) (xy 188.895521 88.989967) (xy 189.032281 88.898587) (xy 189.148587 88.782281) (xy 189.239967 88.645521) + (xy 189.302911 88.49356) (xy 189.335 88.33224) (xy 189.335 88.263) (xy 194.333247 88.263) (xy 194.360035 88.284984) + (xy 194.492064 88.355556) (xy 194.635325 88.399013) (xy 194.746978 88.41001) (xy 194.784311 88.413687) (xy 194.821644 88.41001) + (xy 194.995018 88.41001) (xy 194.988412 88.414424) (xy 194.614424 88.788412) (xy 194.320583 89.228175) (xy 194.118183 89.716814) + (xy 194.015 90.235551) (xy 194.015 90.764449) (xy 194.118183 91.283186) (xy 194.123749 91.296623) (xy 193.901302 91.147989) + (xy 193.592012 91.019877) (xy 193.627932 90.933158) (xy 193.685 90.64626) (xy 193.685 90.35374) (xy 193.627932 90.066842) + (xy 193.51599 89.796589) (xy 193.353475 89.553368) (xy 193.146632 89.346525) (xy 192.903411 89.18401) (xy 192.633158 89.072068) + (xy 192.34626 89.015) (xy 192.176697 89.015) (xy 192.082327 88.975911) (xy 191.776109 88.915) (xy 191.463891 88.915) + (xy 191.157673 88.975911) (xy 190.869221 89.095391) (xy 190.609621 89.26885) (xy 190.38885 89.489621) (xy 190.215391 89.749221) + (xy 190.095911 90.037673) (xy 190.035 90.343891) (xy 190.035 90.656109) (xy 190.095911 90.962327) (xy 190.215391 91.250779) + (xy 190.343113 91.441928) (xy 189.565185 91.441928) (xy 189.600812 91.324482) (xy 189.613072 91.2) (xy 189.613072 89.9) + (xy 189.600812 89.775518) (xy 189.564502 89.65582) (xy 189.505537 89.545506) (xy 189.426185 89.448815) (xy 189.329494 89.369463) + (xy 189.21918 89.310498) (xy 189.099482 89.274188) (xy 188.975 89.261928) (xy 188.025 89.261928) (xy 187.900518 89.274188) + (xy 187.78082 89.310498) (xy 187.670506 89.369463) (xy 187.573815 89.448815) (xy 187.494463 89.545506) (xy 187.435498 89.65582) + (xy 187.399188 89.775518) (xy 187.386928 89.9) (xy 187.386928 91.2) (xy 187.399188 91.324482) (xy 187.435498 91.44418) + (xy 187.494463 91.554494) (xy 187.573815 91.651185) (xy 187.665 91.726018) (xy 187.665 91.83224) (xy 187.697089 91.99356) + (xy 187.760033 92.145521) (xy 187.851413 92.282281) (xy 187.855401 92.286269) (xy 187.865026 92.304276) (xy 187.911928 92.361426) + (xy 187.911928 94.08) (xy 187.924188 94.204482) (xy 187.960498 94.32418) (xy 188.019463 94.434494) (xy 188.098815 94.531185) + (xy 188.195506 94.610537) (xy 188.30582 94.669502) (xy 188.425518 94.705812) (xy 188.55 94.718072) (xy 188.967859 94.718072) + (xy 188.994454 94.805746) (xy 189.065026 94.937776) (xy 189.135789 95.024) (xy 189.16 95.053501) (xy 189.188998 95.077299) + (xy 193.222701 99.111003) (xy 193.246499 99.140001) (xy 193.362224 99.234974) (xy 193.494253 99.305546) (xy 193.637514 99.349003) + (xy 193.749167 99.36) (xy 193.749175 99.36) (xy 193.7865 99.363676) (xy 193.823825 99.36) (xy 201.028048 99.36) + (xy 201.06537 99.363676) (xy 201.102692 99.36) (xy 201.102703 99.36) (xy 201.214356 99.349003) (xy 201.357617 99.305546) + (xy 201.489646 99.234974) (xy 201.605371 99.140001) (xy 201.629173 99.110998) (xy 202.308471 98.431701) (xy 202.337468 98.407904) + (xy 202.432441 98.292179) (xy 202.503013 98.16015) (xy 202.54647 98.016889) (xy 202.557467 97.905236) (xy 202.557467 97.905235) + (xy 202.561144 97.867903) (xy 202.557467 97.83057) (xy 202.557467 97.506036) (xy 202.600378 97.402439) (xy 202.629095 97.258072) + (xy 203.55 97.258072) (xy 203.674482 97.245812) (xy 203.79418 97.209502) (xy 203.904494 97.150537) (xy 204.001185 97.071185) + (xy 204.080537 96.974494) (xy 204.139502 96.86418) (xy 204.175812 96.744482) (xy 204.188072 96.62) (xy 204.188072 94.62) + (xy 204.175812 94.495518) (xy 204.139502 94.37582) (xy 204.080537 94.265506) (xy 204.001185 94.168815) (xy 203.904494 94.089463) + (xy 203.801873 94.03461) (xy 203.834974 93.994276) (xy 203.905546 93.862247) (xy 203.949003 93.718986) (xy 203.96 93.607333) + (xy 203.96 93.607323) (xy 203.963676 93.57) (xy 203.96 93.532677) (xy 203.96 87.532657) (xy 204.002911 87.42906) + (xy 204.035 87.26774) (xy 204.035 87.10326) (xy 204.002911 86.94194) (xy 203.939967 86.789979) (xy 203.848587 86.653219) + (xy 203.846583 86.651215) (xy 205.237798 85.26) (xy 206.477843 85.26) (xy 206.58144 85.302911) (xy 206.662716 85.319078) + (xy 206.685498 85.39418) (xy 206.744463 85.504494) (xy 206.823815 85.601185) (xy 206.920506 85.680537) (xy 207.03082 85.739502) + (xy 207.150518 85.775812) (xy 207.275 85.788072) (xy 208.225 85.788072) (xy 208.349482 85.775812) (xy 208.46918 85.739502) + (xy 208.579494 85.680537) (xy 208.676185 85.601185) (xy 208.755537 85.504494) (xy 208.814502 85.39418) (xy 208.850812 85.274482) + (xy 208.863072 85.15) (xy 208.863072 83.85) (xy 208.850812 83.725518) (xy 208.814502 83.60582) (xy 208.755537 83.495506) + (xy 208.676185 83.398815) (xy 208.579494 83.319463) (xy 208.46918 83.260498) (xy 208.349482 83.224188) (xy 208.225 83.211928) + (xy 207.275 83.211928) (xy 207.150518 83.224188) (xy 207.03082 83.260498) (xy 206.920506 83.319463) (xy 206.823815 83.398815) + (xy 206.744463 83.495506) (xy 206.685498 83.60582) (xy 206.662716 83.680922) (xy 206.58144 83.697089) (xy 206.477843 83.74) + (xy 204.960318 83.74) (xy 204.922995 83.736324) (xy 204.885672 83.74) (xy 204.885663 83.74) (xy 204.77401 83.750997) + (xy 204.638025 83.792247) (xy 204.630749 83.794454) (xy 204.498719 83.865026) (xy 204.416769 83.932281) (xy 204.382995 83.959999) + (xy 204.359197 83.988997) (xy 202.303695 86.0445) (xy 200.41875 86.0445) (xy 200.37625 86.002) (xy 199.227 86.002) + (xy 199.227 86.022) (xy 199.16 86.022) (xy 199.16 85.728) (xy 199.227 85.728) (xy 199.227 85.748) + (xy 200.37625 85.748) (xy 200.535 85.58925) (xy 200.536495 85.485) (xy 200.68224 85.485) (xy 200.84356 85.452911) + (xy 200.995521 85.389967) (xy 201.132281 85.298587) (xy 201.248587 85.182281) (xy 201.339967 85.045521) (xy 201.402911 84.89356) + (xy 201.435 84.73224) (xy 201.435 84.56776) (xy 201.402911 84.40644) (xy 201.339967 84.254479) (xy 201.248587 84.117719) + (xy 201.132281 84.001413) (xy 200.995521 83.910033) (xy 200.891923 83.867122) (xy 200.638803 83.614002) (xy 200.615001 83.584999) + (xy 200.527021 83.512796) (xy 200.525812 83.500518) (xy 200.489502 83.38082) (xy 200.430537 83.270506) (xy 200.351185 83.173815) + (xy 200.254494 83.094463) (xy 200.14418 83.035498) (xy 200.024482 82.999188) (xy 199.9 82.986928) (xy 199.16 82.986928) + (xy 199.16 82.784877) (xy 199.163435 82.75) (xy 199.149727 82.610816) (xy 199.109128 82.47698) (xy 199.0432 82.353637) + (xy 198.954475 82.245525) (xy 198.846363 82.1568) (xy 198.72302 82.090872) (xy 198.589184 82.050273) (xy 198.484877 82.04) + (xy 198.45 82.036565) (xy 198.415123 82.04) (xy 194.984877 82.04) (xy 194.95 82.036565) (xy 194.915123 82.04) + (xy 194.810816 82.050273) (xy 194.67698 82.090872) (xy 194.553637 82.1568) (xy 194.445525 82.245525) (xy 194.3568 82.353637) + (xy 194.290872 82.47698) (xy 194.250273 82.610816) (xy 194.236565 82.75) (xy 194.240001 82.784887) (xy 194.240001 82.986928) + (xy 193.5 82.986928) (xy 193.375518 82.999188) (xy 193.25582 83.035498) (xy 193.145506 83.094463) (xy 193.048815 83.173815) + (xy 192.976691 83.261699) (xy 192.839187 83.303411) (xy 192.685441 83.385589) (xy 192.550683 83.496183) (xy 192.522966 83.529956) + (xy 192.51 83.542922) (xy 192.51 81.964801) (xy 193.891924 80.582878) (xy 193.995521 80.539967) (xy 194.132281 80.448587) + (xy 194.248587 80.332281) (xy 194.339967 80.195521) (xy 194.402911 80.04356) (xy 194.435 79.88224) (xy 194.435 79.71776) + (xy 194.402911 79.55644) (xy 194.342254 79.41) (xy 201.152843 79.41) (xy 201.25644 79.452911) (xy 201.41776 79.485) + (xy 201.58224 79.485) (xy 201.74356 79.452911) (xy 201.895521 79.389967) (xy 202.032281 79.298587) (xy 202.148587 79.182281) + (xy 202.239967 79.045521) (xy 202.302911 78.89356) (xy 202.335 78.73224) (xy 202.335 78.56776) (xy 202.302911 78.40644) + (xy 202.26 78.302843) (xy 202.26 78.058072) (xy 203.55 78.058072) (xy 203.674482 78.045812) (xy 203.79418 78.009502) + (xy 203.904494 77.950537) (xy 204.001185 77.871185) (xy 204.080537 77.774494) (xy 204.139502 77.66418) (xy 204.175812 77.544482) + (xy 204.188072 77.42) (xy 204.188072 75.42) (xy 204.175812 75.295518) (xy 204.139502 75.17582) (xy 204.080537 75.065506) + (xy 204.001185 74.968815) (xy 203.904494 74.889463) (xy 203.79418 74.830498) (xy 203.674482 74.794188) (xy 203.55 74.781928) + (xy 202.430748 74.781928) (xy 202.562953 74.462756) (xy 202.645 74.050279) (xy 202.645 73.629721) (xy 202.562953 73.217244) + (xy 202.402012 72.828698) (xy 202.364985 72.773283) (xy 202.530779 72.704609) (xy 202.790379 72.53115) (xy 203.01115 72.310379) + (xy 203.184609 72.050779) (xy 203.202699 72.007105) (xy 203.260033 72.145521) (xy 203.351413 72.282281) (xy 203.467719 72.398587) + (xy 203.604479 72.489967) (xy 203.75644 72.552911) (xy 203.91776 72.585) (xy 204.08224 72.585) (xy 204.24356 72.552911) + (xy 204.395521 72.489967) (xy 204.532281 72.398587) (xy 204.648587 72.282281) (xy 204.739967 72.145521) (xy 204.802911 71.99356) + (xy 204.835 71.83224) (xy 204.835 71.66776) (xy 204.802911 71.50644) (xy 204.756513 71.394426) (xy 204.749003 71.318172) + (xy 204.705546 71.174911) (xy 204.634974 71.042882) (xy 204.540001 70.927157) (xy 204.511004 70.90336) (xy 202.021645 68.414002) + (xy 201.997842 68.384998) (xy 201.882117 68.290025) (xy 201.750088 68.219453) (xy 201.606827 68.175996) (xy 201.495174 68.164999) + (xy 201.495163 68.164999) (xy 201.463948 68.161924) (xy 201.452911 68.10644) (xy 201.389967 67.954479) (xy 201.298587 67.817719) + (xy 201.182281 67.701413) (xy 201.045521 67.610033) (xy 200.89356 67.547089) (xy 200.73224 67.515) (xy 200.56776 67.515) + (xy 200.417981 67.544793) (xy 200.430537 67.529494) (xy 200.489502 67.41918) (xy 200.525812 67.299482) (xy 200.538072 67.175) + (xy 200.535 66.96075) (xy 200.399115 66.824865) (xy 200.406444 66.827901) (xy 200.567764 66.85999) (xy 200.732244 66.85999) + (xy 200.893564 66.827901) (xy 201.045525 66.764957) (xy 201.182285 66.673577) (xy 201.298591 66.557271) (xy 201.389971 66.420511) + (xy 201.452915 66.26855) (xy 201.485004 66.10723) (xy 201.485004 65.94275) (xy 201.452915 65.78143) (xy 201.389971 65.629469) + (xy 201.298591 65.492709) (xy 201.182285 65.376403) (xy 201.045525 65.285023) (xy 200.941927 65.242112) (xy 200.538072 64.838257) + (xy 200.538072 64.425) (xy 200.525812 64.300518) (xy 200.489502 64.18082) (xy 200.430537 64.070506) (xy 200.351185 63.973815) + (xy 200.254494 63.894463) (xy 200.14418 63.835498) (xy 200.024482 63.799188) (xy 199.9 63.786928) (xy 199.16 63.786928) + (xy 199.16 63.584877) (xy 199.163435 63.55) (xy 199.149727 63.410816) (xy 199.109128 63.27698) (xy 199.101694 63.263072) + (xy 200.7 63.263072) (xy 200.824482 63.250812) (xy 200.94418 63.214502) (xy 201.054494 63.155537) (xy 201.151185 63.076185) + (xy 201.230537 62.979494) (xy 201.289502 62.86918) (xy 201.324735 62.753032) (xy 201.432001 62.665001) (xy 201.455803 62.635998) + (xy 201.911002 62.1808) (xy 201.940001 62.157001) (xy 202.034974 62.041276) (xy 202.105546 61.909247) (xy 202.149003 61.765985) + (xy 202.16 61.654332) (xy 202.16 61.654324) (xy 202.163676 61.617001) (xy 202.161391 61.593799) (xy 202.202911 61.49356) + (xy 202.235 61.33224) (xy 202.235 61.16776) (xy 202.202911 61.00644) (xy 202.139967 60.854479) (xy 202.048587 60.717719) + (xy 201.932281 60.601413) (xy 201.795521 60.510033) (xy 201.64356 60.447089) (xy 201.48224 60.415) (xy 201.31776 60.415) + (xy 201.15644 60.447089) (xy 201.023872 60.502) (xy 199.827 60.502) (xy 199.827 60.522) (xy 199.573 60.522) + (xy 199.573 60.502) (xy 198.22375 60.502) (xy 198.065 60.66075) (xy 198.061928 60.875) (xy 198.074188 60.999482) + (xy 198.110498 61.11918) (xy 198.140947 61.176146) (xy 197.727795 60.762994) (xy 197.703993 60.733991) (xy 197.588268 60.639018) + (xy 197.456239 60.568446) (xy 197.312978 60.524989) (xy 197.201325 60.513992) (xy 197.201314 60.513992) (xy 197.163992 60.510316) + (xy 197.12667 60.513992) (xy 196.938072 60.513992) (xy 196.938072 60.065001) (xy 198.064652 60.065001) (xy 198.065 60.08925) + (xy 198.22375 60.248) (xy 199.573 60.248) (xy 199.573 60.228) (xy 199.827 60.228) (xy 199.827 60.248) + (xy 201.17625 60.248) (xy 201.335 60.08925) (xy 201.338072 59.875) (xy 201.325812 59.750518) (xy 201.306837 59.687964) + (xy 201.836729 59.158072) (xy 203.55 59.158072) (xy 203.674482 59.145812) (xy 203.79418 59.109502) (xy 203.904494 59.050537) + (xy 204.001185 58.971185) (xy 204.080537 58.874494) (xy 204.139502 58.76418) (xy 204.175812 58.644482) (xy 204.188072 58.52) + (xy 204.188072 56.52) (xy 204.175812 56.395518) (xy 204.139502 56.27582) (xy 204.080537 56.165506) (xy 204.001185 56.068815) + (xy 203.904494 55.989463) (xy 203.79418 55.930498) (xy 203.674482 55.894188) (xy 203.55 55.881928) (xy 202.430748 55.881928) + (xy 202.562953 55.562756) (xy 202.645 55.150279) (xy 202.645 54.729721) (xy 202.562953 54.317244) (xy 202.402012 53.928698) + (xy 202.364985 53.873283) (xy 202.530779 53.804609) (xy 202.790379 53.63115) (xy 202.993917 53.427612) (xy 202.997089 53.44356) + (xy 203.060033 53.595521) (xy 203.151413 53.732281) (xy 203.267719 53.848587) (xy 203.404479 53.939967) (xy 203.55644 54.002911) + (xy 203.71776 54.035) (xy 203.88224 54.035) (xy 204.04356 54.002911) (xy 204.195521 53.939967) (xy 204.332281 53.848587) + (xy 204.448587 53.732281) (xy 204.539967 53.595521) (xy 204.602911 53.44356) (xy 204.635 53.28224) (xy 204.635 53.11776) + (xy 204.602911 52.95644) (xy 204.56 52.852843) (xy 204.56 52.570331) (xy 204.563677 52.532998) (xy 204.556491 52.460033) + (xy 204.549003 52.384012) (xy 204.505546 52.240751) (xy 204.434974 52.108722) (xy 204.340001 51.992997) (xy 204.311004 51.9692) + (xy 203.101803 50.76) (xy 204.503874 50.76) (xy 204.509815 50.761802) (xy 204.6588 50.776476) (xy 204.807786 50.761802) + (xy 204.813727 50.76) (xy 204.962678 50.76) (xy 205 50.763676) (xy 205.037322 50.76) (xy 205.037333 50.76) + (xy 205.148986 50.749003) (xy 205.292247 50.705546) (xy 205.424276 50.634974) (xy 205.540001 50.540001) (xy 205.563804 50.510997) + (xy 206.77865 49.296151) (xy 206.823815 49.351185) (xy 206.920506 49.430537) (xy 207.03082 49.489502) (xy 207.150518 49.525812) + (xy 207.275 49.538072) (xy 208.225 49.538072) (xy 208.349482 49.525812) (xy 208.46918 49.489502) (xy 208.579494 49.430537) + (xy 208.676185 49.351185) (xy 208.755537 49.254494) (xy 208.814502 49.14418) (xy 208.850812 49.024482) (xy 208.863072 48.9) + (xy 208.863072 47.6) (xy 208.850812 47.475518) (xy 208.840614 47.4419) (xy 209.280778 47.4419) (xy 209.3181 47.445576) + (xy 209.355422 47.4419) (xy 209.355433 47.4419) (xy 209.467086 47.430903) (xy 209.610347 47.387446) (xy 209.742376 47.316874) + (xy 209.858101 47.221901) (xy 209.881904 47.192897) (xy 210.091922 46.982879) (xy 210.195521 46.939967) (xy 210.332281 46.848587) + (xy 210.448587 46.732281) (xy 210.536199 46.60116) + ) + ) + (filled_polygon + (pts + (xy 148.886928 100.99) (xy 148.899188 101.114482) (xy 148.935498 101.23418) (xy 148.994463 101.344494) (xy 149.073815 101.441185) + (xy 149.170506 101.520537) (xy 149.28082 101.579502) (xy 149.400518 101.615812) (xy 149.525 101.628072) (xy 150.213271 101.628072) + (xy 150.840001 102.254803) (xy 150.840001 103.131928) (xy 150.45 103.131928) (xy 150.325518 103.144188) (xy 150.20582 103.180498) + (xy 150.095506 103.239463) (xy 149.998815 103.318815) (xy 149.919463 103.415506) (xy 149.860498 103.52582) (xy 149.824188 103.645518) + (xy 149.811928 103.77) (xy 149.811928 105.77) (xy 149.824188 105.894482) (xy 149.860498 106.01418) (xy 149.919463 106.124494) + (xy 149.998815 106.221185) (xy 150.095506 106.300537) (xy 150.0962 106.300908) (xy 150.065 106.45776) (xy 150.065 106.62224) + (xy 150.097089 106.78356) (xy 150.160033 106.935521) (xy 150.251413 107.072281) (xy 150.367719 107.188587) (xy 150.504479 107.279967) + (xy 150.65644 107.342911) (xy 150.81776 107.375) (xy 150.98224 107.375) (xy 151.14356 107.342911) (xy 151.295521 107.279967) + (xy 151.432281 107.188587) (xy 151.548587 107.072281) (xy 151.639967 106.935521) (xy 151.702911 106.78356) (xy 151.735 106.62224) + (xy 151.735 106.45776) (xy 151.725116 106.408072) (xy 152.75 106.408072) (xy 152.874482 106.395812) (xy 152.99418 106.359502) + (xy 153.104494 106.300537) (xy 153.201185 106.221185) (xy 153.228525 106.187872) (xy 153.429017 106.388364) (xy 153.778698 106.622013) + (xy 153.994302 106.711319) (xy 153.925 107.059721) (xy 153.925 107.480279) (xy 154.007047 107.892756) (xy 154.167988 108.281302) + (xy 154.401637 108.630983) (xy 154.699017 108.928363) (xy 155.048698 109.162012) (xy 155.437244 109.322953) (xy 155.849721 109.405) + (xy 156.270279 109.405) (xy 156.682756 109.322953) (xy 157.071302 109.162012) (xy 157.420983 108.928363) (xy 157.718363 108.630983) + (xy 157.952012 108.281302) (xy 158.112953 107.892756) (xy 158.195 107.480279) (xy 158.195 107.059721) (xy 158.112953 106.647244) + (xy 157.952012 106.258698) (xy 157.718363 105.909017) (xy 157.420983 105.611637) (xy 157.071302 105.377988) (xy 156.855698 105.288682) + (xy 156.925 104.94028) (xy 156.925 104.519722) (xy 156.873463 104.260627) (xy 156.888412 104.275576) (xy 157.328175 104.569417) + (xy 157.816814 104.771817) (xy 158.335551 104.875) (xy 158.864449 104.875) (xy 159.383186 104.771817) (xy 159.871825 104.569417) + (xy 160.311588 104.275576) (xy 160.326537 104.260627) (xy 160.275 104.519721) (xy 160.275 104.940279) (xy 160.344302 105.288682) + (xy 160.128698 105.377988) (xy 159.779017 105.611637) (xy 159.481637 105.909017) (xy 159.247988 106.258698) (xy 159.087047 106.647244) + (xy 159.005 107.059721) (xy 159.005 107.480279) (xy 159.087047 107.892756) (xy 159.247988 108.281302) (xy 159.481637 108.630983) + (xy 159.779017 108.928363) (xy 160.128698 109.162012) (xy 160.517244 109.322953) (xy 160.929721 109.405) (xy 161.350279 109.405) + (xy 161.762756 109.322953) (xy 162.151302 109.162012) (xy 162.500983 108.928363) (xy 162.640001 108.789345) (xy 162.64 109.192843) + (xy 162.597089 109.29644) (xy 162.565 109.45776) (xy 162.565 109.62224) (xy 162.597089 109.78356) (xy 162.660033 109.935521) + (xy 162.751413 110.072281) (xy 162.867719 110.188587) (xy 163.004479 110.279967) (xy 163.15644 110.342911) (xy 163.31776 110.375) + (xy 163.48224 110.375) (xy 163.64356 110.342911) (xy 163.795521 110.279967) (xy 163.932281 110.188587) (xy 164.048587 110.072281) + (xy 164.139967 109.935521) (xy 164.202911 109.78356) (xy 164.235 109.62224) (xy 164.235 109.45776) (xy 164.202911 109.29644) + (xy 164.16 109.192843) (xy 164.16 108.948072) (xy 165.45 108.948072) (xy 165.539991 108.939209) (xy 165.539991 110.98001) + (xy 154.878455 110.98001) (xy 154.834989 110.975729) (xy 154.791523 110.98001) (xy 154.791513 110.98001) (xy 154.6615 110.992815) + (xy 154.494677 111.043421) (xy 154.340931 111.125599) (xy 154.322186 111.140983) (xy 154.239943 111.208478) (xy 154.239941 111.20848) + (xy 154.206173 111.236193) (xy 154.17846 111.269961) (xy 153.75491 111.693511) (xy 153.76 111.641833) (xy 153.76 111.641825) + (xy 153.763676 111.6045) (xy 153.76 111.567175) (xy 153.76 109.387157) (xy 153.802911 109.28356) (xy 153.835 109.12224) + (xy 153.835 108.95776) (xy 153.802911 108.79644) (xy 153.739967 108.644479) (xy 153.648587 108.507719) (xy 153.532281 108.391413) + (xy 153.395521 108.300033) (xy 153.24356 108.237089) (xy 153.08224 108.205) (xy 152.91776 108.205) (xy 152.75644 108.237089) + (xy 152.604479 108.300033) (xy 152.467719 108.391413) (xy 152.351413 108.507719) (xy 152.260033 108.644479) (xy 152.197089 108.79644) + (xy 152.165 108.95776) (xy 152.165 109.12224) (xy 152.197089 109.28356) (xy 152.24 109.387157) (xy 152.240001 111.289697) + (xy 149.837099 113.6926) (xy 145.613382 113.6926) (xy 147.323009 111.982974) (xy 147.352001 111.959181) (xy 147.375795 111.930188) + (xy 147.375799 111.930184) (xy 147.445279 111.845521) (xy 147.446974 111.843456) (xy 147.517546 111.711427) (xy 147.561003 111.568166) + (xy 147.572 111.456513) (xy 147.572 111.456504) (xy 147.575676 111.419181) (xy 147.572 111.381858) (xy 147.572 101.978301) + (xy 148.31912 101.231182) (xy 148.424276 101.174974) (xy 148.540001 101.080001) (xy 148.563804 101.050997) (xy 148.886928 100.727873) + ) + ) + (filled_polygon + (pts + (xy 129.886928 105.6) (xy 129.899188 105.724482) (xy 129.935498 105.84418) (xy 129.994463 105.954494) (xy 130.073815 106.051185) + (xy 130.170506 106.130537) (xy 130.28082 106.189502) (xy 130.376794 106.218615) (xy 130.431174 106.284877) (xy 130.46 106.320001) + (xy 130.488998 106.343799) (xy 130.711928 106.566729) (xy 130.711928 108.28) (xy 130.724188 108.404482) (xy 130.760498 108.52418) + (xy 130.819463 108.634494) (xy 130.898815 108.731185) (xy 130.979066 108.797045) (xy 130.965 108.86776) (xy 130.965 109.03224) + (xy 130.997089 109.19356) (xy 131.060033 109.345521) (xy 131.151413 109.482281) (xy 131.267719 109.598587) (xy 131.404479 109.689967) + (xy 131.55644 109.752911) (xy 131.71776 109.785) (xy 131.88224 109.785) (xy 132.04356 109.752911) (xy 132.195521 109.689967) + (xy 132.332281 109.598587) (xy 132.448587 109.482281) (xy 132.539967 109.345521) (xy 132.602911 109.19356) (xy 132.635 109.03224) + (xy 132.635 108.918072) (xy 133.65 108.918072) (xy 133.774482 108.905812) (xy 133.89418 108.869502) (xy 134.004494 108.810537) + (xy 134.101185 108.731185) (xy 134.128525 108.697872) (xy 134.329017 108.898364) (xy 134.678698 109.132013) (xy 134.894302 109.221319) + (xy 134.825 109.569721) (xy 134.825 109.990279) (xy 134.907047 110.402756) (xy 135.067988 110.791302) (xy 135.301637 111.140983) + (xy 135.599017 111.438363) (xy 135.948698 111.672012) (xy 136.337244 111.832953) (xy 136.749721 111.915) (xy 137.170279 111.915) + (xy 137.582756 111.832953) (xy 137.971302 111.672012) (xy 138.320983 111.438363) (xy 138.618363 111.140983) (xy 138.852012 110.791302) + (xy 139.012953 110.402756) (xy 139.095 109.990279) (xy 139.095 109.569721) (xy 139.012953 109.157244) (xy 138.852012 108.768698) + (xy 138.618363 108.419017) (xy 138.320983 108.121637) (xy 137.971302 107.887988) (xy 137.755698 107.798682) (xy 137.825 107.45028) + (xy 137.825 107.029722) (xy 137.773463 106.770627) (xy 137.788412 106.785576) (xy 138.228175 107.079417) (xy 138.716814 107.281817) + (xy 139.235551 107.385) (xy 139.764449 107.385) (xy 140.283186 107.281817) (xy 140.771825 107.079417) (xy 141.211588 106.785576) + (xy 141.226537 106.770627) (xy 141.175 107.029721) (xy 141.175 107.450279) (xy 141.244302 107.798682) (xy 141.028698 107.887988) + (xy 140.679017 108.121637) (xy 140.381637 108.419017) (xy 140.147988 108.768698) (xy 139.987047 109.157244) (xy 139.905 109.569721) + (xy 139.905 109.990279) (xy 139.987047 110.402756) (xy 140.147988 110.791302) (xy 140.381637 111.140983) (xy 140.679017 111.438363) + (xy 141.028698 111.672012) (xy 141.417244 111.832953) (xy 141.829721 111.915) (xy 142.250279 111.915) (xy 142.662756 111.832953) + (xy 143.051302 111.672012) (xy 143.400983 111.438363) (xy 143.54 111.299346) (xy 143.54 111.602843) (xy 143.497089 111.70644) + (xy 143.465 111.86776) (xy 143.465 112.03224) (xy 143.497089 112.19356) (xy 143.560033 112.345521) (xy 143.651413 112.482281) + (xy 143.767719 112.598587) (xy 143.904479 112.689967) (xy 144.05644 112.752911) (xy 144.21776 112.785) (xy 144.371378 112.785) + (xy 143.913789 113.24259) (xy 135.727933 113.24259) (xy 135.69061 113.238914) (xy 135.653287 113.24259) (xy 135.653277 113.24259) + (xy 135.541624 113.253587) (xy 135.398363 113.297044) (xy 135.266334 113.367616) (xy 135.150609 113.462589) (xy 135.126806 113.491593) + (xy 135.011811 113.606588) (xy 131.618213 113.606588) (xy 133.102736 112.122066) (xy 133.16776 112.135) (xy 133.33224 112.135) + (xy 133.49356 112.102911) (xy 133.645521 112.039967) (xy 133.782281 111.948587) (xy 133.898587 111.832281) (xy 133.989967 111.695521) + (xy 134.052911 111.54356) (xy 134.085 111.38224) (xy 134.085 111.21776) (xy 134.052911 111.05644) (xy 133.989967 110.904479) + (xy 133.898587 110.767719) (xy 133.782281 110.651413) (xy 133.645521 110.560033) (xy 133.49356 110.497089) (xy 133.33224 110.465) + (xy 133.16776 110.465) (xy 133.00644 110.497089) (xy 132.902843 110.54) (xy 132.887322 110.54) (xy 132.849999 110.536324) + (xy 132.812677 110.54) (xy 132.812667 110.54) (xy 132.701014 110.550997) (xy 132.557753 110.594454) (xy 132.425724 110.665026) + (xy 132.309999 110.759999) (xy 132.286196 110.789003) (xy 132.239003 110.836196) (xy 132.238997 110.836201) (xy 130.26255 112.812649) + (xy 130.233546 112.836452) (xy 130.186192 112.894154) (xy 130.138573 112.952177) (xy 130.08925 113.044454) (xy 130.068001 113.084207) + (xy 130.024544 113.227468) (xy 130.021007 113.26338) (xy 129.970636 113.384987) (xy 129.938547 113.546307) (xy 129.938547 113.606588) + (xy 129.71506 113.606588) (xy 129.715105 113.60644) (xy 129.753403 113.480186) (xy 129.7644 113.368533) (xy 129.7644 113.368524) + (xy 129.768076 113.331201) (xy 129.7644 113.293878) (xy 129.7644 105.460401) (xy 129.886928 105.337873) + ) + ) + (filled_polygon + (pts + (xy 220.515009 105.737686) (xy 220.511333 105.775009) (xy 220.515009 105.812331) (xy 220.515009 105.812341) (xy 220.526006 105.923994) + (xy 220.56071 106.038399) (xy 220.569463 106.067255) (xy 220.640035 106.199285) (xy 220.677105 106.244454) (xy 220.735008 106.31501) + (xy 220.764012 106.338813) (xy 222.090001 107.664803) (xy 222.090001 108.532799) (xy 222.06115 108.489621) (xy 221.840379 108.26885) + (xy 221.580779 108.095391) (xy 221.292327 107.975911) (xy 220.986109 107.915) (xy 220.673891 107.915) (xy 220.367673 107.975911) + (xy 220.273303 108.015) (xy 220.10374 108.015) (xy 219.816842 108.072068) (xy 219.546589 108.18401) (xy 219.303368 108.346525) + (xy 219.096525 108.553368) (xy 218.93401 108.796589) (xy 218.822068 109.066842) (xy 218.765 109.35374) (xy 218.765 109.64626) + (xy 218.822068 109.933158) (xy 218.857988 110.019876) (xy 218.548698 110.147988) (xy 218.326252 110.296622) (xy 218.331817 110.283186) + (xy 218.435 109.764449) (xy 218.435 109.235551) (xy 218.331817 108.716814) (xy 218.129417 108.228175) (xy 217.835576 107.788412) + (xy 217.461588 107.414424) (xy 217.021825 107.120583) (xy 216.5762 106.936) (xy 217.465123 106.936) (xy 217.5 106.939435) + (xy 217.534877 106.936) (xy 217.581076 106.93145) (xy 217.639184 106.925727) (xy 217.77302 106.885128) (xy 217.896363 106.8192) + (xy 218.004475 106.730475) (xy 218.0932 106.622363) (xy 218.159128 106.49902) (xy 218.199727 106.365184) (xy 218.21 106.260877) + (xy 218.21 106.260876) (xy 218.213435 106.226) (xy 218.21 106.191123) (xy 218.21 106.01) (xy 218.277002 106.01) + (xy 218.277002 105.851252) (xy 218.43575 106.01) (xy 218.95 106.013072) (xy 219.074482 106.000812) (xy 219.19418 105.964502) + (xy 219.304494 105.905537) (xy 219.401185 105.826185) (xy 219.480537 105.729494) (xy 219.539502 105.61918) (xy 219.575812 105.499482) + (xy 219.588072 105.375) (xy 219.585 105.16075) (xy 219.42625 105.002) (xy 218.277 105.002) (xy 218.277 105.022) + (xy 218.21 105.022) (xy 218.21 104.728) (xy 218.277 104.728) (xy 218.277 104.748) (xy 219.42625 104.748) + (xy 219.585 104.58925) (xy 219.588072 104.375) (xy 219.575812 104.250518) (xy 219.539502 104.13082) (xy 219.480537 104.020506) + (xy 219.463708 104) (xy 219.480537 103.979494) (xy 219.490957 103.96) (xy 219.50724 103.96) (xy 219.66856 103.927911) + (xy 219.820521 103.864967) (xy 219.957281 103.773587) (xy 220.073587 103.657281) (xy 220.083447 103.642525) (xy 220.088803 103.635998) + (xy 220.361002 103.3638) (xy 220.390001 103.340001) (xy 220.484974 103.224276) (xy 220.51501 103.168084) + ) + ) + (filled_polygon + (pts + (xy 187.74 97.314802) (xy 187.740001 103.757317) (xy 187.670506 103.794463) (xy 187.573815 103.873815) (xy 187.494463 103.970506) + (xy 187.435498 104.08082) (xy 187.399188 104.200518) (xy 187.386928 104.325) (xy 187.386928 105.625) (xy 187.399188 105.749482) + (xy 187.435498 105.86918) (xy 187.494463 105.979494) (xy 187.573815 106.076185) (xy 187.670506 106.155537) (xy 187.78082 106.214502) + (xy 187.900518 106.250812) (xy 188.025 106.263072) (xy 188.650908 106.263072) (xy 188.702317 106.340011) (xy 188.252309 106.340011) + (xy 188.214986 106.336335) (xy 188.177663 106.340011) (xy 188.177654 106.340011) (xy 188.066001 106.351008) (xy 187.92274 106.394465) + (xy 187.790711 106.465037) (xy 187.674986 106.56001) (xy 187.651188 106.589008) (xy 186.2054 108.034797) (xy 186.2054 100.763672) + (xy 186.26108 100.746782) (xy 186.371394 100.687817) (xy 186.468085 100.608465) (xy 186.547437 100.511774) (xy 186.606402 100.40146) + (xy 186.642712 100.281762) (xy 186.654972 100.15728) (xy 186.654972 99.52228) (xy 186.642712 99.397798) (xy 186.624997 99.3394) + (xy 186.642712 99.281002) (xy 186.654972 99.15652) (xy 186.654972 98.52152) (xy 186.642712 98.397038) (xy 186.606402 98.27734) + (xy 186.547437 98.167026) (xy 186.468085 98.070335) (xy 186.371394 97.990983) (xy 186.26108 97.932018) (xy 186.234999 97.924106) + (xy 186.234999 96.710558) (xy 186.27791 96.606961) (xy 186.309999 96.445641) (xy 186.309999 96.281161) (xy 186.27791 96.119841) + (xy 186.234999 96.016244) (xy 186.234999 95.8098) + ) + ) + (filled_polygon + (pts + (xy 127.115 102.268079) (xy 127.115 106.692528) (xy 127.104089 106.637673) (xy 126.984609 106.349221) (xy 126.81115 106.089621) + (xy 126.590379 105.86885) (xy 126.330779 105.695391) (xy 126.042327 105.575911) (xy 125.736109 105.515) (xy 125.423891 105.515) + (xy 125.117673 105.575911) (xy 125.023303 105.615) (xy 124.85374 105.615) (xy 124.566842 105.672068) (xy 124.296589 105.78401) + (xy 124.053368 105.946525) (xy 123.846525 106.153368) (xy 123.68401 106.396589) (xy 123.572068 106.666842) (xy 123.515 106.95374) + (xy 123.515 107.24626) (xy 123.572068 107.533158) (xy 123.607988 107.619876) (xy 123.298698 107.747988) (xy 123.076252 107.896622) + (xy 123.081817 107.883186) (xy 123.185 107.364449) (xy 123.185 106.835551) (xy 123.081817 106.316814) (xy 122.879417 105.828175) + (xy 122.585576 105.388412) (xy 122.211588 105.014424) (xy 121.771825 104.720583) (xy 121.384142 104.56) (xy 122.215123 104.56) + (xy 122.25 104.563435) (xy 122.284877 104.56) (xy 122.389184 104.549727) (xy 122.52302 104.509128) (xy 122.646363 104.4432) + (xy 122.754475 104.354475) (xy 122.8432 104.246363) (xy 122.909128 104.12302) (xy 122.949727 103.989184) (xy 122.963435 103.85) + (xy 122.96 103.815123) (xy 122.96 103.61) (xy 123.027002 103.61) (xy 123.027002 103.451252) (xy 123.18575 103.61) + (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) (xy 124.151185 103.426185) + (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) (xy 124.335 102.76075) + (xy 124.17625 102.602) (xy 123.027 102.602) (xy 123.027 102.622) (xy 122.96 102.622) (xy 122.96 102.328) + (xy 123.027 102.328) (xy 123.027 102.348) (xy 124.17625 102.348) (xy 124.218867 102.305383) (xy 124.36776 102.335) + (xy 124.53224 102.335) (xy 124.69356 102.302911) (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) + (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) + (xy 125.207568 101.146971) (xy 125.199003 101.060014) (xy 125.155546 100.916753) (xy 125.084974 100.784724) (xy 124.990001 100.668999) + (xy 124.960998 100.645197) (xy 124.529804 100.214003) (xy 124.506001 100.184999) (xy 124.390276 100.090026) (xy 124.309538 100.04687) + (xy 124.289502 99.98082) (xy 124.230537 99.870506) (xy 124.151185 99.773815) (xy 124.054494 99.694463) (xy 123.94418 99.635498) + (xy 123.824482 99.599188) (xy 123.7 99.586928) (xy 122.96 99.586928) (xy 122.96 99.384877) (xy 122.963435 99.35) + (xy 122.957033 99.285) (xy 124.131922 99.285) + ) + ) + (filled_polygon + (pts + (xy 116.661928 102.369729) (xy 116.661928 102.975) (xy 116.674188 103.099482) (xy 116.710498 103.21918) (xy 116.769463 103.329494) + (xy 116.848815 103.426185) (xy 116.945506 103.505537) (xy 117.05582 103.564502) (xy 117.175518 103.600812) (xy 117.3 103.613072) + (xy 118.04 103.613072) (xy 118.04 103.815123) (xy 118.036565 103.85) (xy 118.050273 103.989184) (xy 118.090872 104.12302) + (xy 118.1568 104.246363) (xy 118.245525 104.354475) (xy 118.337726 104.430142) (xy 118.353637 104.4432) (xy 118.47698 104.509128) + (xy 118.610816 104.549727) (xy 118.75 104.563435) (xy 118.784877 104.56) (xy 119.615858 104.56) (xy 119.228175 104.720583) + (xy 118.788412 105.014424) (xy 118.414424 105.388412) (xy 118.120583 105.828175) (xy 117.935001 106.276212) (xy 117.935001 105.511922) + (xy 117.938677 105.474599) (xy 117.935001 105.437276) (xy 117.935001 105.437267) (xy 117.924004 105.325614) (xy 117.880547 105.182353) + (xy 117.809975 105.050324) (xy 117.767843 104.998986) (xy 117.7388 104.963596) (xy 117.738796 104.963592) (xy 117.715002 104.934599) + (xy 117.68601 104.910806) (xy 116.5205 103.745298) (xy 116.5205 102.228301) + ) + ) + (filled_polygon + (pts + (xy 203.129712 100.870692) (xy 203.354727 101.413928) (xy 203.681399 101.902826) (xy 204.097174 102.318601) (xy 204.586072 102.645273) + (xy 205.129308 102.870288) (xy 205.706003 102.985) (xy 206.273805 102.985) (xy 206.255088 103.030187) (xy 206.222999 103.191507) + (xy 206.222999 103.278393) (xy 206.195521 103.260033) (xy 206.04356 103.197089) (xy 205.88224 103.165) (xy 205.71776 103.165) + (xy 205.55644 103.197089) (xy 205.404479 103.260033) (xy 205.267719 103.351413) (xy 205.151413 103.467719) (xy 205.060033 103.604479) + (xy 205.017122 103.708076) (xy 204.089002 104.636197) (xy 204.088997 104.636201) (xy 202.835189 105.89001) (xy 200.273414 105.89001) + (xy 200.351185 105.826185) (xy 200.430537 105.729494) (xy 200.489502 105.61918) (xy 200.525812 105.499482) (xy 200.538072 105.375) + (xy 200.535 105.16075) (xy 200.37625 105.002) (xy 199.227 105.002) (xy 199.227 105.022) (xy 199.16 105.022) + (xy 199.16 104.728) (xy 199.227 104.728) (xy 199.227 104.748) (xy 200.37625 104.748) (xy 200.535 104.58925) + (xy 200.535438 104.558679) (xy 200.66776 104.585) (xy 200.83224 104.585) (xy 200.99356 104.552911) (xy 201.145521 104.489967) + (xy 201.282281 104.398587) (xy 201.398587 104.282281) (xy 201.489967 104.145521) (xy 201.552911 103.99356) (xy 201.585 103.83224) + (xy 201.585 103.66776) (xy 201.552911 103.50644) (xy 201.489967 103.354479) (xy 201.398587 103.217719) (xy 201.282281 103.101413) + (xy 201.145521 103.010033) (xy 201.041924 102.967122) (xy 200.688803 102.614002) (xy 200.665001 102.584999) (xy 200.549276 102.490026) + (xy 200.517473 102.473026) (xy 200.489502 102.38082) (xy 200.430537 102.270506) (xy 200.351185 102.173815) (xy 200.254494 102.094463) + (xy 200.236785 102.084997) (xy 202.006532 102.084997) (xy 202.050001 102.089278) (xy 202.09347 102.084997) (xy 202.093478 102.084997) + (xy 202.223491 102.072192) (xy 202.390314 102.021586) (xy 202.54406 101.939408) (xy 202.678818 101.828814) (xy 202.706535 101.795041) + (xy 202.906532 101.595044) (xy 202.98941 101.494057) (xy 203.071588 101.340311) (xy 203.122194 101.173489) (xy 203.139281 100.999999) + (xy 203.12344 100.839161) + ) + ) + (filled_polygon + (pts + (xy 173.869463 100.929494) (xy 173.948815 101.026185) (xy 174.045506 101.105537) (xy 174.15582 101.164502) (xy 174.275518 101.200812) + (xy 174.4 101.213072) (xy 175.14 101.213072) (xy 175.14 101.515123) (xy 175.136565 101.55) (xy 175.150273 101.689184) + (xy 175.190872 101.82302) (xy 175.2568 101.946363) (xy 175.345525 102.054475) (xy 175.409811 102.107233) (xy 175.453637 102.1432) + (xy 175.57698 102.209128) (xy 175.710816 102.249727) (xy 175.85 102.263435) (xy 175.884877 102.26) (xy 176.474436 102.26) + (xy 176.328175 102.320583) (xy 175.888412 102.614424) (xy 175.514424 102.988412) (xy 175.220583 103.428175) (xy 175.018183 103.916814) + (xy 174.915 104.435551) (xy 174.915 104.964449) (xy 175.018183 105.483186) (xy 175.023749 105.496623) (xy 174.801302 105.347989) + (xy 174.492012 105.219877) (xy 174.527932 105.133158) (xy 174.585 104.84626) (xy 174.585 104.55374) (xy 174.527932 104.266842) + (xy 174.41599 103.996589) (xy 174.253475 103.753368) (xy 174.046632 103.546525) (xy 173.803411 103.38401) (xy 173.533158 103.272068) + (xy 173.24626 103.215) (xy 173.076697 103.215) (xy 172.982327 103.175911) (xy 172.676109 103.115) (xy 172.363891 103.115) + (xy 172.057673 103.175911) (xy 171.769221 103.295391) (xy 171.509621 103.46885) (xy 171.28885 103.689621) (xy 171.115391 103.949221) + (xy 170.995911 104.237673) (xy 170.936442 104.53664) (xy 170.363072 103.963271) (xy 170.363072 103.66) (xy 170.775864 103.66) + (xy 170.813186 103.663676) (xy 170.850508 103.66) (xy 170.850519 103.66) (xy 170.962172 103.649003) (xy 171.105433 103.605546) + (xy 171.237462 103.534974) (xy 171.353187 103.440001) (xy 171.37699 103.410997) (xy 173.865642 100.922346) + ) + ) + (filled_polygon + (pts + (xy 181.64 92.602843) (xy 181.597089 92.70644) (xy 181.565 92.86776) (xy 181.565 93.03224) (xy 181.597089 93.19356) + (xy 181.660033 93.345521) (xy 181.751413 93.482281) (xy 181.867719 93.598587) (xy 182.004479 93.689967) (xy 182.108078 93.732879) + (xy 183.195002 94.819804) (xy 183.195001 103.197729) (xy 183.142327 103.175911) (xy 182.836109 103.115) (xy 182.523891 103.115) + (xy 182.217673 103.175911) (xy 182.123303 103.215) (xy 181.95374 103.215) (xy 181.666842 103.272068) (xy 181.396589 103.38401) + (xy 181.153368 103.546525) (xy 180.946525 103.753368) (xy 180.78401 103.996589) (xy 180.672068 104.266842) (xy 180.615 104.55374) + (xy 180.615 104.84626) (xy 180.672068 105.133158) (xy 180.707988 105.219876) (xy 180.398698 105.347988) (xy 180.176252 105.496622) + (xy 180.181817 105.483186) (xy 180.285 104.964449) (xy 180.285 104.435551) (xy 180.181817 103.916814) (xy 179.979417 103.428175) + (xy 179.685576 102.988412) (xy 179.311588 102.614424) (xy 178.871825 102.320583) (xy 178.725564 102.26) (xy 179.315123 102.26) + (xy 179.35 102.263435) (xy 179.384877 102.26) (xy 179.457932 102.252805) (xy 179.489184 102.249727) (xy 179.62302 102.209128) + (xy 179.746363 102.1432) (xy 179.854475 102.054475) (xy 179.9432 101.946363) (xy 180.009128 101.82302) (xy 180.049727 101.689184) + (xy 180.06 101.584877) (xy 180.06 101.584876) (xy 180.063435 101.55) (xy 180.06 101.515123) (xy 180.06 101.21) + (xy 180.127002 101.21) (xy 180.127002 101.051252) (xy 180.28575 101.21) (xy 180.8 101.213072) (xy 180.924482 101.200812) + (xy 181.04418 101.164502) (xy 181.154494 101.105537) (xy 181.251185 101.026185) (xy 181.330537 100.929494) (xy 181.389502 100.81918) + (xy 181.425812 100.699482) (xy 181.438072 100.575) (xy 181.435 100.36075) (xy 181.27625 100.202) (xy 180.127 100.202) + (xy 180.127 100.222) (xy 180.06 100.222) (xy 180.06 99.928) (xy 180.127 99.928) (xy 180.127 99.948) + (xy 181.27625 99.948) (xy 181.435 99.78925) (xy 181.436074 99.714346) (xy 181.49356 99.702911) (xy 181.645521 99.639967) + (xy 181.782281 99.548587) (xy 181.898587 99.432281) (xy 181.989967 99.295521) (xy 182.052911 99.14356) (xy 182.085 98.98224) + (xy 182.085 98.81776) (xy 182.052911 98.65644) (xy 182.012218 98.558199) (xy 182.01 98.535676) (xy 182.01 98.535668) + (xy 181.999003 98.424015) (xy 181.955546 98.280753) (xy 181.884974 98.148724) (xy 181.790001 98.032999) (xy 181.760997 98.009196) + (xy 181.602304 97.850503) (xy 181.578501 97.821499) (xy 181.462776 97.726526) (xy 181.426462 97.707115) (xy 181.425812 97.700518) + (xy 181.389502 97.58082) (xy 181.330537 97.470506) (xy 181.251185 97.373815) (xy 181.154494 97.294463) (xy 181.04418 97.235498) + (xy 180.924482 97.199188) (xy 180.8 97.186928) (xy 180.76 97.186928) (xy 180.76 96.537322) (xy 180.763676 96.499999) + (xy 180.76 96.462676) (xy 180.76 96.462667) (xy 180.749003 96.351014) (xy 180.705546 96.207753) (xy 180.634974 96.075724) + (xy 180.540001 95.959999) (xy 180.511003 95.936201) (xy 179.074999 94.500198) (xy 179.074999 92.536132) (xy 179.128698 92.572012) + (xy 179.517244 92.732953) (xy 179.929721 92.815) (xy 180.350279 92.815) (xy 180.762756 92.732953) (xy 181.151302 92.572012) + (xy 181.500983 92.338363) (xy 181.640001 92.199345) + ) + ) + (filled_polygon + (pts + (xy 143.215 92.60723) (xy 143.247089 92.76855) (xy 143.310033 92.920511) (xy 143.401413 93.057271) (xy 143.517719 93.173577) + (xy 143.654479 93.264957) (xy 143.758078 93.307869) (xy 145.095002 94.644794) (xy 145.095001 103.197729) (xy 145.042327 103.175911) + (xy 144.736109 103.115) (xy 144.423891 103.115) (xy 144.117673 103.175911) (xy 144.023303 103.215) (xy 143.85374 103.215) + (xy 143.566842 103.272068) (xy 143.296589 103.38401) (xy 143.053368 103.546525) (xy 142.846525 103.753368) (xy 142.68401 103.996589) + (xy 142.572068 104.266842) (xy 142.515 104.55374) (xy 142.515 104.84626) (xy 142.572068 105.133158) (xy 142.607988 105.219876) + (xy 142.298698 105.347988) (xy 142.076252 105.496622) (xy 142.081817 105.483186) (xy 142.185 104.964449) (xy 142.185 104.435551) + (xy 142.081817 103.916814) (xy 141.879417 103.428175) (xy 141.585576 102.988412) (xy 141.211588 102.614424) (xy 140.771825 102.320583) + (xy 140.625564 102.26) (xy 141.215123 102.26) (xy 141.25 102.263435) (xy 141.284877 102.26) (xy 141.357932 102.252805) + (xy 141.389184 102.249727) (xy 141.52302 102.209128) (xy 141.646363 102.1432) (xy 141.754475 102.054475) (xy 141.8432 101.946363) + (xy 141.909128 101.82302) (xy 141.949727 101.689184) (xy 141.96 101.584877) (xy 141.96 101.584876) (xy 141.963435 101.55) + (xy 141.96 101.515123) (xy 141.96 101.21) (xy 142.027002 101.21) (xy 142.027002 101.051252) (xy 142.18575 101.21) + (xy 142.7 101.213072) (xy 142.824482 101.200812) (xy 142.94418 101.164502) (xy 143.054494 101.105537) (xy 143.151185 101.026185) + (xy 143.230537 100.929494) (xy 143.289502 100.81918) (xy 143.325812 100.699482) (xy 143.338072 100.575) (xy 143.335 100.36075) + (xy 143.17625 100.202) (xy 142.027 100.202) (xy 142.027 100.222) (xy 141.96 100.222) (xy 141.96 99.928) + (xy 142.027 99.928) (xy 142.027 99.948) (xy 143.17625 99.948) (xy 143.296264 99.827986) (xy 143.35644 99.852911) + (xy 143.51776 99.885) (xy 143.68224 99.885) (xy 143.84356 99.852911) (xy 143.995521 99.789967) (xy 144.132281 99.698587) + (xy 144.248587 99.582281) (xy 144.339967 99.445521) (xy 144.402911 99.29356) (xy 144.435 99.13224) (xy 144.435 98.96776) + (xy 144.402911 98.80644) (xy 144.340821 98.65654) (xy 144.305546 98.540253) (xy 144.234974 98.408224) (xy 144.140001 98.292499) + (xy 144.111004 98.268702) (xy 143.556303 97.714002) (xy 143.532501 97.684999) (xy 143.416776 97.590026) (xy 143.284747 97.519454) + (xy 143.251273 97.5093) (xy 143.230537 97.470506) (xy 143.151185 97.373815) (xy 143.054494 97.294463) (xy 142.94418 97.235498) + (xy 142.824482 97.199188) (xy 142.71 97.187913) (xy 142.71 96.587323) (xy 142.713676 96.55) (xy 142.71 96.512677) + (xy 142.71 96.512667) (xy 142.699003 96.401014) (xy 142.655546 96.257753) (xy 142.616016 96.183799) (xy 142.584974 96.125723) + (xy 142.513799 96.038997) (xy 142.490001 96.009999) (xy 142.461004 95.986202) (xy 140.974999 94.500198) (xy 140.974999 92.536132) + (xy 141.028698 92.572012) (xy 141.417244 92.732953) (xy 141.829721 92.815) (xy 142.250279 92.815) (xy 142.662756 92.732953) + (xy 143.051302 92.572012) (xy 143.215 92.462633) + ) + ) + (filled_polygon + (pts + (xy 168.601413 98.367719) (xy 168.510033 98.504479) (xy 168.447089 98.65644) (xy 168.415 98.81776) (xy 168.415 98.98224) + (xy 168.447089 99.14356) (xy 168.459533 99.173602) (xy 168.420506 99.194463) (xy 168.323815 99.273815) (xy 168.244463 99.370506) + (xy 168.185498 99.48082) (xy 168.149188 99.600518) (xy 168.136928 99.725) (xy 168.136928 101.025) (xy 168.149188 101.149482) + (xy 168.185498 101.26918) (xy 168.244463 101.379494) (xy 168.323815 101.476185) (xy 168.420506 101.555537) (xy 168.53082 101.614502) + (xy 168.650518 101.650812) (xy 168.775 101.663072) (xy 169.725 101.663072) (xy 169.849482 101.650812) (xy 169.96918 101.614502) + (xy 170.079494 101.555537) (xy 170.176185 101.476185) (xy 170.255537 101.379494) (xy 170.314502 101.26918) (xy 170.350812 101.149482) + (xy 170.363072 101.025) (xy 170.363072 99.725) (xy 170.350812 99.600518) (xy 170.314502 99.48082) (xy 170.255537 99.370506) + (xy 170.176185 99.273815) (xy 170.079494 99.194463) (xy 170.040467 99.173602) (xy 170.052911 99.14356) (xy 170.085 98.98224) + (xy 170.085 98.81776) (xy 170.052911 98.65644) (xy 169.989967 98.504479) (xy 169.898587 98.367719) (xy 169.840858 98.30999) + (xy 170.970412 98.30999) (xy 171.965 99.304578) (xy 171.965 99.706521) (xy 171.960718 99.749999) (xy 171.977804 99.923489) + (xy 172.028411 100.090312) (xy 172.110589 100.244058) (xy 172.193467 100.345045) (xy 172.19347 100.345048) (xy 172.221183 100.378816) + (xy 172.242266 100.396118) (xy 170.498385 102.14) (xy 168.60232 102.14) (xy 168.564997 102.136324) (xy 168.527674 102.14) + (xy 168.527665 102.14) (xy 168.416012 102.150997) (xy 168.272751 102.194454) (xy 168.140722 102.265026) (xy 168.14072 102.265027) + (xy 168.140721 102.265027) (xy 168.053994 102.336201) (xy 168.05399 102.336205) (xy 168.024997 102.359999) (xy 168.001203 102.388992) + (xy 167.30999 103.080206) (xy 167.30999 98.30999) (xy 168.659142 98.30999) + ) + ) + (filled_polygon + (pts + (xy 153.121183 96.918817) (xy 153.255941 97.02941) (xy 153.409687 97.111588) (xy 153.57651 97.162195) (xy 153.75 97.179281) + (xy 153.92349 97.162195) (xy 154.090313 97.111588) (xy 154.123162 97.09403) (xy 154.217719 97.188587) (xy 154.354479 97.279967) + (xy 154.458077 97.322879) (xy 154.761928 97.62673) (xy 154.761928 98.065) (xy 154.774188 98.189482) (xy 154.810498 98.30918) + (xy 154.869463 98.419494) (xy 154.948815 98.516185) (xy 155.045506 98.595537) (xy 155.15582 98.654502) (xy 155.275518 98.690812) + (xy 155.4 98.703072) (xy 156.14 98.703072) (xy 156.14 98.895923) (xy 156.136565 98.9308) (xy 156.150273 99.069984) + (xy 156.190872 99.20382) (xy 156.2568 99.327163) (xy 156.345525 99.435275) (xy 156.44263 99.514967) (xy 156.453637 99.524) + (xy 156.57698 99.589928) (xy 156.710816 99.630527) (xy 156.85 99.644235) (xy 156.884877 99.6408) (xy 157.738069 99.6408) + (xy 157.328175 99.810583) (xy 156.888412 100.104424) (xy 156.514424 100.478412) (xy 156.220583 100.918175) (xy 156.018183 101.406814) + (xy 155.915 101.925551) (xy 155.915 102.454449) (xy 156.018183 102.973186) (xy 156.023749 102.986623) (xy 155.801302 102.837989) + (xy 155.492012 102.709877) (xy 155.527932 102.623158) (xy 155.585 102.33626) (xy 155.585 102.04374) (xy 155.527932 101.756842) + (xy 155.41599 101.486589) (xy 155.253475 101.243368) (xy 155.046632 101.036525) (xy 154.803411 100.87401) (xy 154.533158 100.762068) + (xy 154.24626 100.705) (xy 154.076697 100.705) (xy 153.982327 100.665911) (xy 153.676109 100.605) (xy 153.363891 100.605) + (xy 153.057673 100.665911) (xy 152.769221 100.785391) (xy 152.509621 100.95885) (xy 152.28885 101.179621) (xy 152.140881 101.401072) + (xy 152.140001 101.399999) (xy 152.111003 101.376201) (xy 151.113072 100.378271) (xy 151.113072 99.69) (xy 151.100812 99.565518) + (xy 151.064502 99.44582) (xy 151.005537 99.335506) (xy 150.926185 99.238815) (xy 150.829494 99.159463) (xy 150.766603 99.125846) + (xy 150.792002 99.105002) (xy 150.815805 99.075998) (xy 153.054383 96.837421) + ) + ) + (filled_polygon + (pts + (xy 149.149188 60.064482) (xy 149.185498 60.18418) (xy 149.244463 60.294494) (xy 149.323815 60.391185) (xy 149.420506 60.470537) + (xy 149.53082 60.529502) (xy 149.650518 60.565812) (xy 149.775 60.578072) (xy 150.725 60.578072) (xy 150.849482 60.565812) + (xy 150.96918 60.529502) (xy 151.079494 60.470537) (xy 151.176185 60.391185) (xy 151.226112 60.330349) (xy 151.25644 60.342911) + (xy 151.41776 60.375) (xy 151.490001 60.375) (xy 151.490001 62.725198) (xy 151.458078 62.757121) (xy 151.363072 62.796474) + (xy 151.363072 62.19) (xy 151.350812 62.065518) (xy 151.314502 61.94582) (xy 151.255537 61.835506) (xy 151.176185 61.738815) + (xy 151.079494 61.659463) (xy 151.077778 61.658546) (xy 151.085 61.62224) (xy 151.085 61.45776) (xy 151.052911 61.29644) + (xy 150.989967 61.144479) (xy 150.898587 61.007719) (xy 150.782281 60.891413) (xy 150.645521 60.800033) (xy 150.49356 60.737089) + (xy 150.33224 60.705) (xy 150.16776 60.705) (xy 150.00644 60.737089) (xy 149.854479 60.800033) (xy 149.717719 60.891413) + (xy 149.601413 61.007719) (xy 149.510033 61.144479) (xy 149.447089 61.29644) (xy 149.415 61.45776) (xy 149.415 61.62224) + (xy 149.422222 61.658546) (xy 149.420506 61.659463) (xy 149.323815 61.738815) (xy 149.244463 61.835506) (xy 149.185498 61.94582) + (xy 149.149188 62.065518) (xy 149.136928 62.19) (xy 149.136928 63.49) (xy 149.149188 63.614482) (xy 149.185498 63.73418) + (xy 149.244463 63.844494) (xy 149.323815 63.941185) (xy 149.420506 64.020537) (xy 149.49 64.057683) (xy 149.49 64.502677) + (xy 149.486324 64.54) (xy 149.49 64.577322) (xy 149.49 64.577332) (xy 149.500997 64.688985) (xy 149.542559 64.825998) + (xy 149.544454 64.832246) (xy 149.615026 64.964276) (xy 149.648896 65.005546) (xy 149.709999 65.080001) (xy 149.739003 65.103804) + (xy 149.933545 65.298347) (xy 149.919463 65.315506) (xy 149.860498 65.42582) (xy 149.824188 65.545518) (xy 149.811928 65.67) + (xy 149.811928 67.67) (xy 149.824188 67.794482) (xy 149.860498 67.91418) (xy 149.919463 68.024494) (xy 149.998815 68.121185) + (xy 150.095506 68.200537) (xy 150.0962 68.200908) (xy 150.065 68.35776) (xy 150.065 68.52224) (xy 150.097089 68.68356) + (xy 150.160033 68.835521) (xy 150.251413 68.972281) (xy 150.367719 69.088587) (xy 150.504479 69.179967) (xy 150.65644 69.242911) + (xy 150.81776 69.275) (xy 150.98224 69.275) (xy 151.14356 69.242911) (xy 151.295521 69.179967) (xy 151.432281 69.088587) + (xy 151.548587 68.972281) (xy 151.639967 68.835521) (xy 151.702911 68.68356) (xy 151.735 68.52224) (xy 151.735 68.35776) + (xy 151.725116 68.308072) (xy 152.75 68.308072) (xy 152.874482 68.295812) (xy 152.99418 68.259502) (xy 153.104494 68.200537) + (xy 153.201185 68.121185) (xy 153.228525 68.087872) (xy 153.429017 68.288364) (xy 153.778698 68.522013) (xy 153.994302 68.611319) + (xy 153.925 68.959721) (xy 153.925 69.380279) (xy 154.007047 69.792756) (xy 154.167988 70.181302) (xy 154.401637 70.530983) + (xy 154.699017 70.828363) (xy 155.048698 71.062012) (xy 155.437244 71.222953) (xy 155.849721 71.305) (xy 156.270279 71.305) + (xy 156.682756 71.222953) (xy 157.071302 71.062012) (xy 157.420983 70.828363) (xy 157.718363 70.530983) (xy 157.952012 70.181302) + (xy 158.112953 69.792756) (xy 158.195 69.380279) (xy 158.195 68.959721) (xy 158.112953 68.547244) (xy 157.952012 68.158698) + (xy 157.718363 67.809017) (xy 157.420983 67.511637) (xy 157.071302 67.277988) (xy 156.855698 67.188682) (xy 156.925 66.84028) + (xy 156.925 66.419722) (xy 156.873463 66.160627) (xy 156.888412 66.175576) (xy 157.328175 66.469417) (xy 157.816814 66.671817) + (xy 158.335551 66.775) (xy 158.581471 66.775) (xy 158.565996 66.826016) (xy 158.554999 66.937669) (xy 158.554999 66.937679) + (xy 158.551323 66.975001) (xy 158.554999 67.012324) (xy 158.555 71.26851) (xy 153.089003 76.734508) (xy 153.059999 76.758311) + (xy 153.009653 76.819658) (xy 152.965026 76.874036) (xy 152.896223 77.002756) (xy 152.894454 77.006066) (xy 152.850997 77.149327) + (xy 152.84 77.26098) (xy 152.84 77.26099) (xy 152.836324 77.298312) (xy 152.84 77.335634) (xy 152.84 77.692843) + (xy 152.797089 77.79644) (xy 152.765 77.95776) (xy 152.765 78.12224) (xy 152.797089 78.28356) (xy 152.860033 78.435521) + (xy 152.951413 78.572281) (xy 153.067719 78.688587) (xy 153.204479 78.779967) (xy 153.308077 78.822878) (xy 153.5612 79.076002) + (xy 153.584999 79.105001) (xy 153.613997 79.128799) (xy 153.700723 79.199974) (xy 153.813021 79.259999) (xy 153.832753 79.270546) + (xy 153.976014 79.314003) (xy 154.087667 79.325) (xy 154.087676 79.325) (xy 154.124999 79.328676) (xy 154.162322 79.325) + (xy 154.818954 79.325) (xy 154.869463 79.419494) (xy 154.948815 79.516185) (xy 154.995868 79.5548) (xy 150.863072 79.5548) + (xy 150.863072 79.14) (xy 150.850812 79.015518) (xy 150.814502 78.89582) (xy 150.755537 78.785506) (xy 150.676185 78.688815) + (xy 150.579494 78.609463) (xy 150.46918 78.550498) (xy 150.349482 78.514188) (xy 150.225 78.501928) (xy 149.275 78.501928) + (xy 149.150518 78.514188) (xy 149.03082 78.550498) (xy 148.920506 78.609463) (xy 148.823815 78.688815) (xy 148.744463 78.785506) + (xy 148.685498 78.89582) (xy 148.649188 79.015518) (xy 148.636928 79.14) (xy 148.636928 80.178975) (xy 148.610011 80.176324) + (xy 148.572688 80.18) (xy 148.572679 80.18) (xy 148.461026 80.190997) (xy 148.333259 80.229754) (xy 148.317765 80.234454) + (xy 148.185735 80.305026) (xy 148.109933 80.367236) (xy 148.070011 80.399999) (xy 148.046213 80.428997) (xy 147.208089 81.267121) + (xy 147.104491 81.310033) (xy 146.967731 81.401413) (xy 146.851425 81.517719) (xy 146.760045 81.654479) (xy 146.697101 81.80644) + (xy 146.665012 81.96776) (xy 146.665012 82.13224) (xy 146.697101 82.29356) (xy 146.760045 82.445521) (xy 146.851425 82.582281) + (xy 146.967731 82.698587) (xy 147.104491 82.789967) (xy 147.256452 82.852911) (xy 147.417772 82.885) (xy 147.582252 82.885) + (xy 147.743572 82.852911) (xy 147.895533 82.789967) (xy 148.032293 82.698587) (xy 148.148599 82.582281) (xy 148.239979 82.445521) + (xy 148.282891 82.341923) (xy 148.924814 81.7) (xy 149.402843 81.7) (xy 149.50644 81.742911) (xy 149.66776 81.775) + (xy 149.83224 81.775) (xy 149.99356 81.742911) (xy 150.145521 81.679967) (xy 150.282281 81.588587) (xy 150.398587 81.472281) + (xy 150.489967 81.335521) (xy 150.552911 81.18356) (xy 150.574545 81.0748) (xy 156.435065 81.0748) (xy 156.535325 81.105213) + (xy 156.646978 81.11621) (xy 156.684311 81.119887) (xy 156.721644 81.11621) (xy 156.876626 81.11621) (xy 156.514424 81.478412) + (xy 156.220583 81.918175) (xy 156.018183 82.406814) (xy 155.915 82.925551) (xy 155.915 83.454449) (xy 156.018183 83.973186) + (xy 156.023749 83.986623) (xy 155.801302 83.837989) (xy 155.492012 83.709877) (xy 155.527932 83.623158) (xy 155.585 83.33626) + (xy 155.585 83.04374) (xy 155.527932 82.756842) (xy 155.41599 82.486589) (xy 155.253475 82.243368) (xy 155.046632 82.036525) + (xy 154.803411 81.87401) (xy 154.533158 81.762068) (xy 154.24626 81.705) (xy 154.076697 81.705) (xy 153.982327 81.665911) + (xy 153.676109 81.605) (xy 153.363891 81.605) (xy 153.057673 81.665911) (xy 152.769221 81.785391) (xy 152.509621 81.95885) + (xy 152.28885 82.179621) (xy 152.115391 82.439221) (xy 151.995911 82.727673) (xy 151.935 83.033891) (xy 151.935 83.346109) + (xy 151.995911 83.652327) (xy 152.115391 83.940779) (xy 152.243113 84.131928) (xy 151.036729 84.131928) (xy 150.863072 83.958271) + (xy 150.863072 82.69) (xy 150.850812 82.565518) (xy 150.814502 82.44582) (xy 150.755537 82.335506) (xy 150.676185 82.238815) + (xy 150.579494 82.159463) (xy 150.46918 82.100498) (xy 150.349482 82.064188) (xy 150.225 82.051928) (xy 149.275 82.051928) + (xy 149.150518 82.064188) (xy 149.03082 82.100498) (xy 148.920506 82.159463) (xy 148.823815 82.238815) (xy 148.744463 82.335506) + (xy 148.685498 82.44582) (xy 148.649188 82.565518) (xy 148.636928 82.69) (xy 148.636928 83.99) (xy 148.649188 84.114482) + (xy 148.685498 84.23418) (xy 148.744463 84.344494) (xy 148.823815 84.441185) (xy 148.920506 84.520537) (xy 149.03082 84.579502) + (xy 149.150518 84.615812) (xy 149.275 84.628072) (xy 149.383271 84.628072) (xy 149.811928 85.056729) (xy 149.811928 86.77) + (xy 149.824188 86.894482) (xy 149.860498 87.01418) (xy 149.919463 87.124494) (xy 149.998815 87.221185) (xy 150.04 87.254985) + (xy 150.04 87.292842) (xy 149.997089 87.39644) (xy 149.965 87.55776) (xy 149.965 87.72224) (xy 149.997089 87.88356) + (xy 150.060033 88.035521) (xy 150.151413 88.172281) (xy 150.267719 88.288587) (xy 150.404479 88.379967) (xy 150.55644 88.442911) + (xy 150.71776 88.475) (xy 150.88224 88.475) (xy 151.04356 88.442911) (xy 151.195521 88.379967) (xy 151.332281 88.288587) + (xy 151.448587 88.172281) (xy 151.539967 88.035521) (xy 151.602911 87.88356) (xy 151.635 87.72224) (xy 151.635 87.55776) + (xy 151.605225 87.408072) (xy 152.75 87.408072) (xy 152.874482 87.395812) (xy 152.99418 87.359502) (xy 153.104494 87.300537) + (xy 153.201185 87.221185) (xy 153.228525 87.187872) (xy 153.429017 87.388364) (xy 153.778698 87.622013) (xy 153.994302 87.711319) + (xy 153.925 88.059721) (xy 153.925 88.480279) (xy 154.007047 88.892756) (xy 154.167988 89.281302) (xy 154.401637 89.630983) + (xy 154.699017 89.928363) (xy 155.048698 90.162012) (xy 155.437244 90.322953) (xy 155.849721 90.405) (xy 156.270279 90.405) + (xy 156.682756 90.322953) (xy 157.071302 90.162012) (xy 157.420983 89.928363) (xy 157.718363 89.630983) (xy 157.952012 89.281302) + (xy 158.112953 88.892756) (xy 158.195 88.480279) (xy 158.195 88.059721) (xy 158.112953 87.647244) (xy 157.952012 87.258698) + (xy 157.718363 86.909017) (xy 157.420983 86.611637) (xy 157.071302 86.377988) (xy 156.855698 86.288682) (xy 156.925 85.94028) + (xy 156.925 85.519722) (xy 156.873463 85.260627) (xy 156.888412 85.275576) (xy 157.328175 85.569417) (xy 157.816814 85.771817) + (xy 158.335551 85.875) (xy 158.864449 85.875) (xy 159.383186 85.771817) (xy 159.871825 85.569417) (xy 160.311588 85.275576) + (xy 160.326537 85.260627) (xy 160.275 85.519721) (xy 160.275 85.940279) (xy 160.344302 86.288682) (xy 160.128698 86.377988) + (xy 159.779017 86.611637) (xy 159.481637 86.909017) (xy 159.247988 87.258698) (xy 159.087047 87.647244) (xy 159.005 88.059721) + (xy 159.005 88.480279) (xy 159.087047 88.892756) (xy 159.247988 89.281302) (xy 159.481637 89.630983) (xy 159.779017 89.928363) + (xy 160.128698 90.162012) (xy 160.517244 90.322953) (xy 160.929721 90.405) (xy 161.350279 90.405) (xy 161.762756 90.322953) + (xy 162.151302 90.162012) (xy 162.500983 89.928363) (xy 162.540001 89.889345) (xy 162.54 90.292843) (xy 162.497089 90.39644) + (xy 162.465 90.55776) (xy 162.465 90.72224) (xy 162.497089 90.88356) (xy 162.560033 91.035521) (xy 162.651413 91.172281) + (xy 162.767719 91.288587) (xy 162.904479 91.379967) (xy 163.008078 91.422879) (xy 164.195001 92.609803) (xy 164.195002 100.687729) + (xy 164.142327 100.665911) (xy 163.836109 100.605) (xy 163.523891 100.605) (xy 163.217673 100.665911) (xy 163.123303 100.705) + (xy 162.95374 100.705) (xy 162.666842 100.762068) (xy 162.396589 100.87401) (xy 162.153368 101.036525) (xy 161.946525 101.243368) + (xy 161.78401 101.486589) (xy 161.672068 101.756842) (xy 161.615 102.04374) (xy 161.615 102.33626) (xy 161.672068 102.623158) + (xy 161.707988 102.709876) (xy 161.398698 102.837988) (xy 161.176252 102.986622) (xy 161.181817 102.973186) (xy 161.285 102.454449) + (xy 161.285 101.925551) (xy 161.181817 101.406814) (xy 160.979417 100.918175) (xy 160.685576 100.478412) (xy 160.311588 100.104424) + (xy 159.871825 99.810583) (xy 159.461931 99.6408) (xy 160.315123 99.6408) (xy 160.35 99.644235) (xy 160.384877 99.6408) + (xy 160.489184 99.630527) (xy 160.62302 99.589928) (xy 160.746363 99.524) (xy 160.854475 99.435275) (xy 160.9432 99.327163) + (xy 161.009128 99.20382) (xy 161.049727 99.069984) (xy 161.063435 98.9308) (xy 161.06 98.895923) (xy 161.06 98.7) + (xy 161.127002 98.7) (xy 161.127002 98.541252) (xy 161.28575 98.7) (xy 161.8 98.703072) (xy 161.924482 98.690812) + (xy 162.04418 98.654502) (xy 162.154494 98.595537) (xy 162.251185 98.516185) (xy 162.330537 98.419494) (xy 162.389502 98.30918) + (xy 162.425812 98.189482) (xy 162.438072 98.065) (xy 162.435 97.85075) (xy 162.27625 97.692) (xy 161.127 97.692) + (xy 161.127 97.712) (xy 161.06 97.712) (xy 161.06 97.418) (xy 161.127 97.418) (xy 161.127 97.438) + (xy 162.27625 97.438) (xy 162.435 97.27925) (xy 162.438072 97.065) (xy 162.425812 96.940518) (xy 162.389502 96.82082) + (xy 162.330537 96.710506) (xy 162.313708 96.69) (xy 162.330537 96.669494) (xy 162.389502 96.55918) (xy 162.425812 96.439482) + (xy 162.438072 96.315) (xy 162.438072 95.315) (xy 162.425812 95.190518) (xy 162.389502 95.07082) (xy 162.330537 94.960506) + (xy 162.263741 94.879115) (xy 162.285 94.77224) (xy 162.285 94.60776) (xy 162.252911 94.44644) (xy 162.189967 94.294479) + (xy 162.098587 94.157719) (xy 161.982281 94.041413) (xy 161.845521 93.950033) (xy 161.741923 93.907122) (xy 161.363803 93.529002) + (xy 161.340001 93.499999) (xy 161.224276 93.405026) (xy 161.092247 93.334454) (xy 160.948986 93.290997) (xy 160.837333 93.28) + (xy 160.837322 93.28) (xy 160.8 93.276324) (xy 160.762678 93.28) (xy 156.584801 93.28) (xy 159.041924 90.822878) + (xy 159.145521 90.779967) (xy 159.282281 90.688587) (xy 159.398587 90.572281) (xy 159.489967 90.435521) (xy 159.552911 90.28356) + (xy 159.585 90.12224) (xy 159.585 89.95776) (xy 159.552911 89.79644) (xy 159.489967 89.644479) (xy 159.398587 89.507719) + (xy 159.282281 89.391413) (xy 159.145521 89.300033) (xy 158.99356 89.237089) (xy 158.83224 89.205) (xy 158.66776 89.205) + (xy 158.50644 89.237089) (xy 158.354479 89.300033) (xy 158.217719 89.391413) (xy 158.101413 89.507719) (xy 158.010033 89.644479) + (xy 157.967122 89.748076) (xy 155.685683 92.029516) (xy 155.64356 92.012068) (xy 155.48224 91.979979) (xy 155.31776 91.979979) + (xy 155.15644 92.012068) (xy 155.004479 92.075012) (xy 154.867719 92.166392) (xy 154.751413 92.282698) (xy 154.660033 92.419458) + (xy 154.597089 92.571419) (xy 154.565 92.732739) (xy 154.565 92.897219) (xy 154.597089 93.058539) (xy 154.660033 93.2105) + (xy 154.708521 93.283068) (xy 154.628016 93.290997) (xy 154.484755 93.334454) (xy 154.352726 93.405026) (xy 154.237001 93.499999) + (xy 154.213203 93.528997) (xy 151.113072 96.629129) (xy 151.113072 96.14) (xy 151.100812 96.015518) (xy 151.064502 95.89582) + (xy 151.005537 95.785506) (xy 150.926185 95.688815) (xy 150.829494 95.609463) (xy 150.71918 95.550498) (xy 150.599482 95.514188) + (xy 150.475 95.501928) (xy 149.525 95.501928) (xy 149.400518 95.514188) (xy 149.28082 95.550498) (xy 149.170506 95.609463) + (xy 149.073815 95.688815) (xy 148.994463 95.785506) (xy 148.935498 95.89582) (xy 148.899188 96.015518) (xy 148.886928 96.14) + (xy 148.886928 97.44) (xy 148.899188 97.564482) (xy 148.935498 97.68418) (xy 148.994463 97.794494) (xy 149.073815 97.891185) + (xy 149.165 97.966018) (xy 149.165 98.02224) (xy 149.197089 98.18356) (xy 149.221853 98.243345) (xy 147.616382 99.848817) + (xy 147.511223 99.905026) (xy 147.438647 99.964588) (xy 147.395499 99.999999) (xy 147.371701 100.028997) (xy 146.615001 100.785698) + (xy 146.615001 94.367314) (xy 146.618677 94.329991) (xy 146.615001 94.292668) (xy 146.615001 94.292658) (xy 146.604004 94.181005) + (xy 146.560547 94.037744) (xy 146.537312 93.994275) (xy 146.489975 93.905714) (xy 146.4188 93.818988) (xy 146.395002 93.78999) + (xy 146.366004 93.766192) (xy 144.957883 92.358072) (xy 146.35 92.358072) (xy 146.474482 92.345812) (xy 146.59418 92.309502) + (xy 146.704494 92.250537) (xy 146.801185 92.171185) (xy 146.880537 92.074494) (xy 146.939502 91.96418) (xy 146.975812 91.844482) + (xy 146.988072 91.72) (xy 146.988072 89.72) (xy 146.975812 89.595518) (xy 146.939502 89.47582) (xy 146.880537 89.365506) + (xy 146.801185 89.268815) (xy 146.704494 89.189463) (xy 146.615001 89.141627) (xy 146.615001 75.492334) (xy 146.618678 75.455001) + (xy 146.604004 75.306015) (xy 146.560547 75.162754) (xy 146.489975 75.030725) (xy 146.4188 74.943998) (xy 146.395002 74.915) + (xy 146.366005 74.891203) (xy 145.082879 73.608078) (xy 145.06 73.552843) (xy 145.06 73.358072) (xy 146.35 73.358072) + (xy 146.474482 73.345812) (xy 146.59418 73.309502) (xy 146.704494 73.250537) (xy 146.801185 73.171185) (xy 146.880537 73.074494) + (xy 146.939502 72.96418) (xy 146.975812 72.844482) (xy 146.988072 72.72) (xy 146.988072 70.72) (xy 146.975812 70.595518) + (xy 146.939502 70.47582) (xy 146.880537 70.365506) (xy 146.801185 70.268815) (xy 146.704494 70.189463) (xy 146.615001 70.141627) + (xy 146.615001 61.896568) (xy 146.77616 61.864511) (xy 146.928121 61.801567) (xy 147.064881 61.710187) (xy 147.181187 61.593881) + (xy 147.272567 61.457121) (xy 147.315478 61.353523) (xy 147.511002 61.158) (xy 147.540001 61.134201) (xy 147.634974 61.018476) + (xy 147.705546 60.886447) (xy 147.749003 60.743185) (xy 147.76 60.631532) (xy 147.76 60.631524) (xy 147.762985 60.601216) + (xy 148.314202 60.05) (xy 149.147762 60.05) + ) + ) + (filled_polygon + (pts + (xy 130 94.49728) (xy 130.043477 94.492998) (xy 131.24142 94.492998) (xy 134.115 97.366579) (xy 134.115001 98.373674) + (xy 134.115 98.373682) (xy 134.115 98.373689) (xy 134.110719 98.417158) (xy 134.115 98.460627) (xy 134.115 99.243481) + (xy 134.127805 99.373494) (xy 134.169523 99.511014) (xy 134.178412 99.540317) (xy 134.26059 99.694063) (xy 134.371184 99.828821) + (xy 134.505942 99.939415) (xy 134.659688 100.021593) (xy 134.826511 100.072199) (xy 135 100.089286) (xy 135.08523 100.080892) + (xy 135.12373 100.127804) (xy 135.16001 100.172011) (xy 135.189008 100.195809) (xy 135.479196 100.485997) (xy 135.502999 100.515001) + (xy 135.618724 100.609974) (xy 135.667965 100.636294) (xy 135.674188 100.699482) (xy 135.710498 100.81918) (xy 135.769463 100.929494) + (xy 135.848815 101.026185) (xy 135.910165 101.076533) (xy 134.378292 102.608407) (xy 131.777354 102.608407) (xy 131.829494 102.580537) + (xy 131.926185 102.501185) (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) + (xy 132.113072 100.75) (xy 132.100812 100.625518) (xy 132.064502 100.50582) (xy 132.005537 100.395506) (xy 131.926185 100.298815) + (xy 131.829494 100.219463) (xy 131.71918 100.160498) (xy 131.599482 100.124188) (xy 131.475 100.111928) (xy 131.463832 100.111928) + (xy 131.902826 99.818601) (xy 132.318601 99.402826) (xy 132.645273 98.913928) (xy 132.870288 98.370692) (xy 132.985 97.793997) + (xy 132.985 97.206003) (xy 132.870288 96.629308) (xy 132.645273 96.086072) (xy 132.318601 95.597174) (xy 131.902826 95.181399) + (xy 131.413928 94.854727) (xy 130.870692 94.629712) (xy 130.293997 94.515) (xy 129.706003 94.515) (xy 129.629325 94.530252) + (xy 129.666579 94.492998) (xy 129.956524 94.492998) + ) + ) + (filled_polygon + (pts + (xy 171.59 79.691579) (xy 171.590001 80.581521) (xy 171.585719 80.625) (xy 171.602805 80.79849) (xy 171.653412 80.965313) + (xy 171.73559 81.119059) (xy 171.818468 81.220046) (xy 171.818471 81.220049) (xy 171.846184 81.253817) (xy 171.879951 81.281529) + (xy 172.504953 81.906532) (xy 172.60594 81.98941) (xy 172.759686 82.071588) (xy 172.926509 82.122194) (xy 173.099999 82.139281) + (xy 173.273489 82.122194) (xy 173.440313 82.071588) (xy 173.594058 81.98941) (xy 173.728816 81.878816) (xy 173.829954 81.75558) + (xy 173.869463 81.829494) (xy 173.948815 81.926185) (xy 174.045506 82.005537) (xy 174.15582 82.064502) (xy 174.275518 82.100812) + (xy 174.4 82.113072) (xy 174.490001 82.113072) (xy 174.49 83.077843) (xy 174.447089 83.18144) (xy 174.415 83.34276) + (xy 174.415 83.50724) (xy 174.447089 83.66856) (xy 174.465 83.711801) (xy 174.465 85.014909) (xy 174.41599 84.896589) + (xy 174.253475 84.653368) (xy 174.046632 84.446525) (xy 173.803411 84.28401) (xy 173.533158 84.172068) (xy 173.24626 84.115) + (xy 173.076697 84.115) (xy 172.982327 84.075911) (xy 172.676109 84.015) (xy 172.363891 84.015) (xy 172.057673 84.075911) + (xy 171.769221 84.195391) (xy 171.509621 84.36885) (xy 171.28885 84.589621) (xy 171.115391 84.849221) (xy 170.995911 85.137673) + (xy 170.935 85.443891) (xy 170.935 85.756109) (xy 170.995911 86.062327) (xy 171.115391 86.350779) (xy 171.243113 86.541928) + (xy 170.579862 86.541928) (xy 170.552911 86.40644) (xy 170.544414 86.385925) (xy 170.554494 86.380537) (xy 170.651185 86.301185) + (xy 170.730537 86.204494) (xy 170.789502 86.09418) (xy 170.825812 85.974482) (xy 170.838072 85.85) (xy 170.838072 84.55) + (xy 170.825812 84.425518) (xy 170.789502 84.30582) (xy 170.730537 84.195506) (xy 170.651185 84.098815) (xy 170.554494 84.019463) + (xy 170.44418 83.960498) (xy 170.324482 83.924188) (xy 170.2 83.911928) (xy 169.25 83.911928) (xy 169.125518 83.924188) + (xy 169.00582 83.960498) (xy 168.895506 84.019463) (xy 168.798815 84.098815) (xy 168.719463 84.195506) (xy 168.660498 84.30582) + (xy 168.624188 84.425518) (xy 168.611928 84.55) (xy 168.611928 85.85) (xy 168.624188 85.974482) (xy 168.660498 86.09418) + (xy 168.719463 86.204494) (xy 168.798815 86.301185) (xy 168.895506 86.380537) (xy 168.946789 86.407949) (xy 168.915 86.56776) + (xy 168.915 86.73224) (xy 168.930803 86.811688) (xy 168.919463 86.825506) (xy 168.860498 86.93582) (xy 168.824188 87.055518) + (xy 168.811928 87.18) (xy 168.811928 89.18) (xy 168.824188 89.304482) (xy 168.860498 89.42418) (xy 168.919463 89.534494) + (xy 168.998815 89.631185) (xy 169.095506 89.710537) (xy 169.0962 89.710908) (xy 169.065 89.86776) (xy 169.065 90.03224) + (xy 169.097089 90.19356) (xy 169.160033 90.345521) (xy 169.251413 90.482281) (xy 169.367719 90.598587) (xy 169.504479 90.689967) + (xy 169.65644 90.752911) (xy 169.81776 90.785) (xy 169.98224 90.785) (xy 170.14356 90.752911) (xy 170.295521 90.689967) + (xy 170.432281 90.598587) (xy 170.548587 90.482281) (xy 170.639967 90.345521) (xy 170.702911 90.19356) (xy 170.735 90.03224) + (xy 170.735 89.86776) (xy 170.725116 89.818072) (xy 171.75 89.818072) (xy 171.874482 89.805812) (xy 171.99418 89.769502) + (xy 172.104494 89.710537) (xy 172.201185 89.631185) (xy 172.228525 89.597872) (xy 172.429017 89.798364) (xy 172.778698 90.032013) + (xy 172.994302 90.121319) (xy 172.925 90.469721) (xy 172.925 90.890279) (xy 173.007047 91.302756) (xy 173.167988 91.691302) + (xy 173.401637 92.040983) (xy 173.699017 92.338363) (xy 174.048698 92.572012) (xy 174.437244 92.732953) (xy 174.849721 92.815) + (xy 175.270279 92.815) (xy 175.682756 92.732953) (xy 176.071302 92.572012) (xy 176.420983 92.338363) (xy 176.718363 92.040983) + (xy 176.952012 91.691302) (xy 177.112953 91.302756) (xy 177.195 90.890279) (xy 177.195 90.469721) (xy 177.112953 90.057244) + (xy 176.957751 89.682552) (xy 177.555 90.279802) (xy 177.554999 94.777676) (xy 177.551323 94.814999) (xy 177.554999 94.852321) + (xy 177.554999 94.852331) (xy 177.565996 94.963984) (xy 177.602854 95.08549) (xy 177.609453 95.107245) (xy 177.680025 95.239275) + (xy 177.711131 95.277177) (xy 177.774998 95.355) (xy 177.804002 95.378803) (xy 178.765198 96.34) (xy 175.884877 96.34) + (xy 175.85 96.336565) (xy 175.815123 96.34) (xy 175.710816 96.350273) (xy 175.57698 96.390872) (xy 175.453637 96.4568) + (xy 175.345525 96.545525) (xy 175.2568 96.653637) (xy 175.190872 96.77698) (xy 175.150273 96.910816) (xy 175.136565 97.05) + (xy 175.140001 97.084887) (xy 175.140001 97.186928) (xy 174.4 97.186928) (xy 174.275518 97.199188) (xy 174.15582 97.235498) + (xy 174.045506 97.294463) (xy 173.948815 97.373815) (xy 173.894499 97.44) (xy 173.406463 97.44) (xy 173.362997 97.435719) + (xy 173.319531 97.44) (xy 173.319521 97.44) (xy 173.189508 97.452805) (xy 173.022685 97.503411) (xy 172.868939 97.585589) + (xy 172.803155 97.639577) (xy 171.993524 96.829946) (xy 171.965807 96.796173) (xy 171.831049 96.685579) (xy 171.677303 96.603401) + (xy 171.51048 96.552795) (xy 171.380467 96.53999) (xy 171.380459 96.53999) (xy 171.33699 96.535709) (xy 171.293521 96.53999) + (xy 167.30999 96.53999) (xy 167.30999 93.54276) (xy 167.915 93.54276) (xy 167.915 93.70724) (xy 167.947089 93.86856) + (xy 168.010033 94.020521) (xy 168.101413 94.157281) (xy 168.217719 94.273587) (xy 168.354479 94.364967) (xy 168.50644 94.427911) + (xy 168.66776 94.46) (xy 168.710199 94.46) (xy 169.217122 94.966923) (xy 169.260033 95.070521) (xy 169.351413 95.207281) + (xy 169.467719 95.323587) (xy 169.604479 95.414967) (xy 169.75644 95.477911) (xy 169.91776 95.51) (xy 170.08224 95.51) + (xy 170.24356 95.477911) (xy 170.395521 95.414967) (xy 170.532281 95.323587) (xy 170.648587 95.207281) (xy 170.739967 95.070521) + (xy 170.802911 94.91856) (xy 170.835 94.75724) (xy 170.835 94.59276) (xy 170.802911 94.43144) (xy 170.739967 94.279479) + (xy 170.648587 94.142719) (xy 170.532281 94.026413) (xy 170.395521 93.935033) (xy 170.291923 93.892122) (xy 169.538804 93.139002) + (xy 169.515001 93.109999) (xy 169.399276 93.015026) (xy 169.267247 92.944454) (xy 169.207183 92.926234) (xy 169.145521 92.885033) + (xy 168.99356 92.822089) (xy 168.83224 92.79) (xy 168.66776 92.79) (xy 168.50644 92.822089) (xy 168.354479 92.885033) + (xy 168.217719 92.976413) (xy 168.101413 93.092719) (xy 168.010033 93.229479) (xy 167.947089 93.38144) (xy 167.915 93.54276) + (xy 167.30999 93.54276) (xy 167.30999 92.981588) (xy 167.981532 92.310047) (xy 168.06441 92.20906) (xy 168.146588 92.055314) + (xy 168.197194 91.888491) (xy 168.214281 91.715001) (xy 168.197194 91.541511) (xy 168.146588 91.374687) (xy 168.06441 91.220942) + (xy 167.953817 91.086183) (xy 167.819058 90.97559) (xy 167.665313 90.893412) (xy 167.498489 90.842806) (xy 167.324999 90.825719) + (xy 167.151509 90.842806) (xy 166.984686 90.893412) (xy 166.83094 90.97559) (xy 166.729953 91.058468) (xy 165.829946 91.958476) + (xy 165.796173 91.986193) (xy 165.693481 92.111324) (xy 165.660547 92.002754) (xy 165.589975 91.870725) (xy 165.495002 91.755) + (xy 165.466005 91.731203) (xy 164.082879 90.348078) (xy 164.06 90.292843) (xy 164.06 89.948072) (xy 165.45 89.948072) + (xy 165.574482 89.935812) (xy 165.69418 89.899502) (xy 165.804494 89.840537) (xy 165.901185 89.761185) (xy 165.980537 89.664494) + (xy 166.039502 89.55418) (xy 166.075812 89.434482) (xy 166.088072 89.31) (xy 166.088072 87.31) (xy 166.075812 87.185518) + (xy 166.039502 87.06582) (xy 165.980537 86.955506) (xy 165.901185 86.858815) (xy 165.804494 86.779463) (xy 165.76 86.75568) + (xy 165.76 81.887178) (xy 165.802911 81.783581) (xy 165.804614 81.77502) (xy 165.866419 81.77502) (xy 166.2524 82.161002) + (xy 166.276199 82.190001) (xy 166.391924 82.284974) (xy 166.523953 82.355546) (xy 166.667214 82.399003) (xy 166.778867 82.41) + (xy 166.778876 82.41) (xy 166.816199 82.413676) (xy 166.853522 82.41) (xy 168.622762 82.41) (xy 168.624188 82.424482) + (xy 168.660498 82.54418) (xy 168.719463 82.654494) (xy 168.798815 82.751185) (xy 168.895506 82.830537) (xy 169.00582 82.889502) + (xy 169.125518 82.925812) (xy 169.25 82.938072) (xy 170.2 82.938072) (xy 170.324482 82.925812) (xy 170.44418 82.889502) + (xy 170.554494 82.830537) (xy 170.651185 82.751185) (xy 170.730537 82.654494) (xy 170.789502 82.54418) (xy 170.825812 82.424482) + (xy 170.827242 82.409965) (xy 170.875521 82.389967) (xy 171.012281 82.298587) (xy 171.128587 82.182281) (xy 171.219967 82.045521) + (xy 171.282911 81.89356) (xy 171.315 81.73224) (xy 171.315 81.56776) (xy 171.282911 81.40644) (xy 171.219967 81.254479) + (xy 171.128587 81.117719) (xy 171.012281 81.001413) (xy 170.875521 80.910033) (xy 170.827242 80.890035) (xy 170.825812 80.875518) + (xy 170.789502 80.75582) (xy 170.730537 80.645506) (xy 170.651185 80.548815) (xy 170.554494 80.469463) (xy 170.44418 80.410498) + (xy 170.324482 80.374188) (xy 170.2 80.361928) (xy 169.25 80.361928) (xy 169.125518 80.374188) (xy 169.00582 80.410498) + (xy 168.895506 80.469463) (xy 168.798815 80.548815) (xy 168.719463 80.645506) (xy 168.660498 80.75582) (xy 168.624188 80.875518) + (xy 168.622762 80.89) (xy 167.131002 80.89) (xy 166.745023 80.504022) (xy 166.721221 80.475019) (xy 166.605496 80.380046) + (xy 166.473467 80.309474) (xy 166.403368 80.28821) (xy 167.691579 79) (xy 170.898422 79) + ) + ) + (filled_polygon + (pts + (xy 124.598815 94.671185) (xy 124.695506 94.750537) (xy 124.790001 94.801046) (xy 124.79 95.252843) (xy 124.747089 95.35644) + (xy 124.715 95.51776) (xy 124.715 95.68224) (xy 124.747089 95.84356) (xy 124.810033 95.995521) (xy 124.901413 96.132281) + (xy 125.017719 96.248587) (xy 125.154479 96.339967) (xy 125.269012 96.387408) (xy 124.14142 97.515) (xy 119.096613 97.515) + (xy 121.726003 94.885611) (xy 121.736651 94.876873) (xy 122.028698 95.072012) (xy 122.417244 95.232953) (xy 122.829721 95.315) + (xy 123.250279 95.315) (xy 123.662756 95.232953) (xy 124.051302 95.072012) (xy 124.400983 94.838363) (xy 124.584998 94.654348) + ) + ) + (filled_polygon + (pts + (xy 139.454999 90.1788) (xy 139.455 94.777667) (xy 139.451323 94.814999) (xy 139.455 94.852331) (xy 139.455 94.852332) + (xy 139.465997 94.963985) (xy 139.477629 95.002331) (xy 139.509453 95.107245) (xy 139.580025 95.239275) (xy 139.647048 95.320942) + (xy 139.674999 95.355) (xy 139.703997 95.378798) (xy 140.665198 96.34) (xy 137.784877 96.34) (xy 137.75 96.336565) + (xy 137.715123 96.34) (xy 137.610816 96.350273) (xy 137.47698 96.390872) (xy 137.353637 96.4568) (xy 137.245525 96.545525) + (xy 137.1568 96.653637) (xy 137.090872 96.77698) (xy 137.050273 96.910816) (xy 137.036565 97.05) (xy 137.040001 97.084887) + (xy 137.040001 97.186928) (xy 136.3 97.186928) (xy 136.175518 97.199188) (xy 136.123396 97.214999) (xy 135.885 97.214999) + (xy 135.885 97.043465) (xy 135.889281 96.999999) (xy 135.885 96.956533) (xy 135.885 96.956523) (xy 135.872195 96.82651) + (xy 135.821589 96.659687) (xy 135.739411 96.505941) (xy 135.684628 96.439188) (xy 135.656532 96.404953) (xy 135.65653 96.404951) + (xy 135.628817 96.371183) (xy 135.59505 96.343471) (xy 132.264532 93.012954) (xy 132.236815 92.979181) (xy 132.102057 92.868587) + (xy 131.948311 92.786409) (xy 131.781488 92.735803) (xy 131.651475 92.722998) (xy 131.651467 92.722998) (xy 131.607998 92.718717) + (xy 131.564529 92.722998) (xy 130.885 92.722998) (xy 130.885 90.407717) (xy 130.901413 90.432281) (xy 131.017719 90.548587) + (xy 131.154479 90.639967) (xy 131.30644 90.702911) (xy 131.46776 90.735) (xy 131.63224 90.735) (xy 131.79356 90.702911) + (xy 131.945521 90.639967) (xy 132.082281 90.548587) (xy 132.198587 90.432281) (xy 132.289967 90.295521) (xy 132.352911 90.14356) + (xy 132.385 89.98224) (xy 132.385 89.818072) (xy 133.65 89.818072) (xy 133.774482 89.805812) (xy 133.89418 89.769502) + (xy 134.004494 89.710537) (xy 134.101185 89.631185) (xy 134.128525 89.597872) (xy 134.329017 89.798364) (xy 134.678698 90.032013) + (xy 134.894302 90.121319) (xy 134.825 90.469721) (xy 134.825 90.890279) (xy 134.907047 91.302756) (xy 135.067988 91.691302) + (xy 135.301637 92.040983) (xy 135.599017 92.338363) (xy 135.948698 92.572012) (xy 136.337244 92.732953) (xy 136.749721 92.815) + (xy 137.170279 92.815) (xy 137.582756 92.732953) (xy 137.971302 92.572012) (xy 138.320983 92.338363) (xy 138.618363 92.040983) + (xy 138.852012 91.691302) (xy 139.012953 91.302756) (xy 139.095 90.890279) (xy 139.095 90.469721) (xy 139.012953 90.057244) + (xy 138.852012 89.668698) (xy 138.664973 89.388773) + ) + ) + (filled_polygon + (pts + (xy 133.732003 57.233582) (xy 133.732002 60.081523) (xy 133.72772 60.125) (xy 133.732002 60.168477) (xy 133.732002 60.268476) + (xy 133.740784 60.357638) (xy 131.583422 62.515) (xy 130.913072 62.515) (xy 130.913072 61.375) (xy 130.900812 61.250518) + (xy 130.864502 61.13082) (xy 130.805537 61.020506) (xy 130.726185 60.923815) (xy 130.629494 60.844463) (xy 130.51918 60.785498) + (xy 130.399482 60.749188) (xy 130.275 60.736928) (xy 129.325 60.736928) (xy 129.200518 60.749188) (xy 129.08082 60.785498) + (xy 128.970506 60.844463) (xy 128.873815 60.923815) (xy 128.794463 61.020506) (xy 128.735498 61.13082) (xy 128.699188 61.250518) + (xy 128.686928 61.375) (xy 128.686928 61.64) (xy 128.587155 61.64) (xy 128.531921 61.617121) (xy 128.403801 61.489002) + (xy 128.379999 61.459999) (xy 128.264274 61.365026) (xy 128.132245 61.294454) (xy 127.988984 61.250997) (xy 127.902482 61.242477) + (xy 127.900812 61.225518) (xy 127.864502 61.10582) (xy 127.805537 60.995506) (xy 127.726185 60.898815) (xy 127.629494 60.819463) + (xy 127.51918 60.760498) (xy 127.399482 60.724188) (xy 127.275 60.711928) (xy 126.325 60.711928) (xy 126.200518 60.724188) + (xy 126.08082 60.760498) (xy 125.970506 60.819463) (xy 125.873815 60.898815) (xy 125.794463 60.995506) (xy 125.735498 61.10582) + (xy 125.699188 61.225518) (xy 125.686928 61.35) (xy 125.686928 62.65) (xy 125.699188 62.774482) (xy 125.735498 62.89418) + (xy 125.794463 63.004494) (xy 125.873815 63.101185) (xy 125.970506 63.180537) (xy 126.08082 63.239502) (xy 126.200518 63.275812) + (xy 126.325 63.288072) (xy 127.275 63.288072) (xy 127.399482 63.275812) (xy 127.51918 63.239502) (xy 127.629494 63.180537) + (xy 127.726185 63.101185) (xy 127.747523 63.075184) (xy 127.844477 63.139967) (xy 127.996438 63.202911) (xy 128.157758 63.235) + (xy 128.322238 63.235) (xy 128.483558 63.202911) (xy 128.538101 63.180319) (xy 128.25495 63.46347) (xy 128.221183 63.491182) + (xy 128.19347 63.52495) (xy 128.193467 63.524953) (xy 128.110589 63.62594) (xy 128.028411 63.779686) (xy 127.977804 63.946509) + (xy 127.960718 64.119999) (xy 127.965 64.163478) (xy 127.964999 68.418532) (xy 127.960718 68.462001) (xy 127.964999 68.50547) + (xy 127.964999 68.505477) (xy 127.971849 68.575027) (xy 127.977804 68.635491) (xy 127.984935 68.658997) (xy 128.02841 68.802313) + (xy 128.110588 68.956059) (xy 128.221182 69.090818) (xy 128.254955 69.118535) (xy 128.565001 69.428582) (xy 128.565 75.979531) + (xy 128.560719 76.023) (xy 128.565 76.066469) (xy 128.565 76.066476) (xy 128.574265 76.160547) (xy 128.577805 76.19649) + (xy 128.580229 76.204479) (xy 128.628411 76.363312) (xy 128.710589 76.517058) (xy 128.821183 76.651817) (xy 128.854956 76.679534) + (xy 131.99547 79.820049) (xy 132.023183 79.853817) (xy 132.056951 79.88153) (xy 132.056953 79.881532) (xy 132.135435 79.945941) + (xy 132.157941 79.964411) (xy 132.19 79.981547) (xy 132.190001 80.815649) (xy 132.176185 80.798815) (xy 132.079494 80.719463) + (xy 131.96918 80.660498) (xy 131.849482 80.624188) (xy 131.725 80.611928) (xy 130.775 80.611928) (xy 130.650518 80.624188) + (xy 130.53082 80.660498) (xy 130.420506 80.719463) (xy 130.323815 80.798815) (xy 130.244463 80.895506) (xy 130.185498 81.00582) + (xy 130.162691 81.081003) (xy 130.08224 81.065) (xy 129.91776 81.065) (xy 129.75644 81.097089) (xy 129.652843 81.14) + (xy 129.57487 81.14) (xy 129.564502 81.10582) (xy 129.505537 80.995506) (xy 129.426185 80.898815) (xy 129.329494 80.819463) + (xy 129.21918 80.760498) (xy 129.099482 80.724188) (xy 128.975 80.711928) (xy 128.025 80.711928) (xy 127.900518 80.724188) + (xy 127.78082 80.760498) (xy 127.670506 80.819463) (xy 127.573815 80.898815) (xy 127.494463 80.995506) (xy 127.435498 81.10582) + (xy 127.399188 81.225518) (xy 127.386928 81.35) (xy 127.386928 82.65) (xy 127.399188 82.774482) (xy 127.435498 82.89418) + (xy 127.494463 83.004494) (xy 127.573815 83.101185) (xy 127.670506 83.180537) (xy 127.78082 83.239502) (xy 127.900518 83.275812) + (xy 128.025 83.288072) (xy 128.975 83.288072) (xy 129.099482 83.275812) (xy 129.21918 83.239502) (xy 129.329494 83.180537) + (xy 129.426185 83.101185) (xy 129.505537 83.004494) (xy 129.564502 82.89418) (xy 129.600812 82.774482) (xy 129.612087 82.66) + (xy 129.652843 82.66) (xy 129.75644 82.702911) (xy 129.91776 82.735) (xy 130.08224 82.735) (xy 130.162691 82.718997) + (xy 130.185498 82.79418) (xy 130.244463 82.904494) (xy 130.323815 83.001185) (xy 130.420506 83.080537) (xy 130.53082 83.139502) + (xy 130.650518 83.175812) (xy 130.775 83.188072) (xy 130.922352 83.188072) (xy 130.645425 83.464999) (xy 130.458464 83.464999) + (xy 130.414998 83.460718) (xy 130.371532 83.464999) (xy 130.371522 83.464999) (xy 130.241509 83.477804) (xy 130.074686 83.52841) + (xy 129.92094 83.610588) (xy 129.786182 83.721182) (xy 129.758467 83.754953) (xy 129.404956 84.108464) (xy 129.371183 84.136181) + (xy 129.260589 84.27094) (xy 129.234942 84.318923) (xy 129.21918 84.310498) (xy 129.099482 84.274188) (xy 128.975 84.261928) + (xy 128.025 84.261928) (xy 127.900518 84.274188) (xy 127.78082 84.310498) (xy 127.670506 84.369463) (xy 127.573815 84.448815) + (xy 127.494463 84.545506) (xy 127.435498 84.65582) (xy 127.399188 84.775518) (xy 127.386928 84.9) (xy 127.386928 86.2) + (xy 127.399188 86.324482) (xy 127.435498 86.44418) (xy 127.494463 86.554494) (xy 127.573815 86.651185) (xy 127.670506 86.730537) + (xy 127.681212 86.736259) (xy 127.665 86.81776) (xy 127.665 86.98224) (xy 127.697089 87.14356) (xy 127.760033 87.295521) + (xy 127.851413 87.432281) (xy 127.967719 87.548587) (xy 128.104479 87.639967) (xy 128.25644 87.702911) (xy 128.41776 87.735) + (xy 128.58224 87.735) (xy 128.74356 87.702911) (xy 128.895521 87.639967) (xy 129.032281 87.548587) (xy 129.115 87.465868) + (xy 129.115001 92.739294) (xy 128.959687 92.786409) (xy 128.805941 92.868587) (xy 128.805939 92.868588) (xy 128.80594 92.868588) + (xy 128.704953 92.951466) (xy 128.704951 92.951468) (xy 128.671183 92.979181) (xy 128.64347 93.012949) (xy 127.988072 93.668347) + (xy 127.988072 92.22) (xy 127.975812 92.095518) (xy 127.939502 91.97582) (xy 127.880537 91.865506) (xy 127.801185 91.768815) + (xy 127.704494 91.689463) (xy 127.59418 91.630498) (xy 127.474482 91.594188) (xy 127.35 91.581928) (xy 126.230748 91.581928) + (xy 126.362953 91.262756) (xy 126.445 90.850279) (xy 126.445 90.429721) (xy 126.362953 90.017244) (xy 126.202012 89.628698) + (xy 126.164985 89.573283) (xy 126.330779 89.504609) (xy 126.590379 89.33115) (xy 126.81115 89.110379) (xy 126.984609 88.850779) + (xy 127.104089 88.562327) (xy 127.165 88.256109) (xy 127.165 87.943891) (xy 127.104089 87.637673) (xy 126.984609 87.349221) + (xy 126.81115 87.089621) (xy 126.590379 86.86885) (xy 126.330779 86.695391) (xy 126.042327 86.575911) (xy 125.736109 86.515) + (xy 125.423891 86.515) (xy 125.117673 86.575911) (xy 125.023303 86.615) (xy 124.87299 86.615) (xy 125.961009 85.526982) + (xy 125.990001 85.503189) (xy 126.013795 85.474196) (xy 126.013799 85.474192) (xy 126.081049 85.392247) (xy 126.084974 85.387464) + (xy 126.155546 85.255435) (xy 126.199003 85.112174) (xy 126.21 85.000521) (xy 126.21 85.000512) (xy 126.213676 84.963189) + (xy 126.21 84.925866) (xy 126.21 83.847157) (xy 126.252911 83.74356) (xy 126.285 83.58224) (xy 126.285 83.41776) + (xy 126.252911 83.25644) (xy 126.21 83.152843) (xy 126.21 82.90251) (xy 126.213676 82.865187) (xy 126.21 82.827864) + (xy 126.21 82.827855) (xy 126.199003 82.716202) (xy 126.155546 82.572941) (xy 126.084974 82.440912) (xy 125.990001 82.325187) + (xy 125.961004 82.30139) (xy 124.873616 81.214002) (xy 124.849813 81.184999) (xy 124.734088 81.090026) (xy 124.602059 81.019454) + (xy 124.458798 80.975997) (xy 124.347145 80.965) (xy 124.347134 80.965) (xy 124.309812 80.961324) (xy 124.280618 80.964199) + (xy 124.230537 80.870506) (xy 124.151185 80.773815) (xy 124.054494 80.694463) (xy 123.94418 80.635498) (xy 123.824482 80.599188) + (xy 123.7 80.586928) (xy 122.96 80.586928) (xy 122.96 80.384877) (xy 122.963435 80.35) (xy 122.949727 80.210816) + (xy 122.909128 80.07698) (xy 122.8432 79.953637) (xy 122.754475 79.845525) (xy 122.646363 79.7568) (xy 122.52302 79.690872) + (xy 122.389184 79.650273) (xy 122.284877 79.64) (xy 122.25 79.636565) (xy 122.215123 79.64) (xy 121.628486 79.64) + (xy 121.635002 79.60724) (xy 121.635002 79.44276) (xy 121.602913 79.28144) (xy 121.560002 79.177843) (xy 121.560002 75.719348) + (xy 121.679017 75.838363) (xy 122.028698 76.072012) (xy 122.417244 76.232953) (xy 122.829721 76.315) (xy 123.250279 76.315) + (xy 123.662756 76.232953) (xy 124.051302 76.072012) (xy 124.400983 75.838363) (xy 124.540001 75.699345) (xy 124.54 76.252843) + (xy 124.497089 76.35644) (xy 124.465 76.51776) (xy 124.465 76.68224) (xy 124.497089 76.84356) (xy 124.560033 76.995521) + (xy 124.651413 77.132281) (xy 124.767719 77.248587) (xy 124.904479 77.339967) (xy 125.05644 77.402911) (xy 125.21776 77.435) + (xy 125.38224 77.435) (xy 125.54356 77.402911) (xy 125.695521 77.339967) (xy 125.832281 77.248587) (xy 125.948587 77.132281) + (xy 126.039967 76.995521) (xy 126.102911 76.84356) (xy 126.135 76.68224) (xy 126.135 76.51776) (xy 126.102911 76.35644) + (xy 126.06 76.252843) (xy 126.06 75.858072) (xy 127.35 75.858072) (xy 127.474482 75.845812) (xy 127.59418 75.809502) + (xy 127.704494 75.750537) (xy 127.801185 75.671185) (xy 127.880537 75.574494) (xy 127.939502 75.46418) (xy 127.975812 75.344482) + (xy 127.988072 75.22) (xy 127.988072 73.22) (xy 127.975812 73.095518) (xy 127.939502 72.97582) (xy 127.880537 72.865506) + (xy 127.801185 72.768815) (xy 127.704494 72.689463) (xy 127.59418 72.630498) (xy 127.474482 72.594188) (xy 127.35 72.581928) + (xy 126.230748 72.581928) (xy 126.362953 72.262756) (xy 126.445 71.850279) (xy 126.445 71.429721) (xy 126.362953 71.017244) + (xy 126.202012 70.628698) (xy 126.164985 70.573283) (xy 126.330779 70.504609) (xy 126.590379 70.33115) (xy 126.81115 70.110379) + (xy 126.984609 69.850779) (xy 127.104089 69.562327) (xy 127.165 69.256109) (xy 127.165 68.943891) (xy 127.104089 68.637673) + (xy 126.984609 68.349221) (xy 126.81115 68.089621) (xy 126.590379 67.86885) (xy 126.330779 67.695391) (xy 126.042327 67.575911) + (xy 125.736109 67.515) (xy 125.423891 67.515) (xy 125.117673 67.575911) (xy 125.023303 67.615) (xy 124.85374 67.615) + (xy 124.566842 67.672068) (xy 124.296589 67.78401) (xy 124.053368 67.946525) (xy 123.846525 68.153368) (xy 123.68401 68.396589) + (xy 123.635001 68.514908) (xy 123.635001 66.319933) (xy 123.663588 66.277149) (xy 123.726532 66.125188) (xy 123.758621 65.963868) + (xy 123.758621 65.799388) (xy 123.726532 65.638068) (xy 123.715544 65.611541) (xy 123.824482 65.600812) (xy 123.94418 65.564502) + (xy 124.054494 65.505537) (xy 124.151185 65.426185) (xy 124.230537 65.329494) (xy 124.289502 65.21918) (xy 124.325812 65.099482) + (xy 124.338072 64.975) (xy 124.336997 64.9) (xy 125.686928 64.9) (xy 125.686928 66.2) (xy 125.699188 66.324482) + (xy 125.735498 66.44418) (xy 125.794463 66.554494) (xy 125.873815 66.651185) (xy 125.970506 66.730537) (xy 125.975095 66.73299) + (xy 125.997089 66.84356) (xy 126.060033 66.995521) (xy 126.151413 67.132281) (xy 126.267719 67.248587) (xy 126.404479 67.339967) + (xy 126.55644 67.402911) (xy 126.71776 67.435) (xy 126.88224 67.435) (xy 127.04356 67.402911) (xy 127.195521 67.339967) + (xy 127.332281 67.248587) (xy 127.448587 67.132281) (xy 127.539967 66.995521) (xy 127.602911 66.84356) (xy 127.624905 66.73299) + (xy 127.629494 66.730537) (xy 127.726185 66.651185) (xy 127.805537 66.554494) (xy 127.864502 66.44418) (xy 127.900812 66.324482) + (xy 127.913072 66.2) (xy 127.913072 64.9) (xy 127.900812 64.775518) (xy 127.864502 64.65582) (xy 127.805537 64.545506) + (xy 127.726185 64.448815) (xy 127.629494 64.369463) (xy 127.51918 64.310498) (xy 127.399482 64.274188) (xy 127.275 64.261928) + (xy 126.325 64.261928) (xy 126.200518 64.274188) (xy 126.08082 64.310498) (xy 125.970506 64.369463) (xy 125.873815 64.448815) + (xy 125.794463 64.545506) (xy 125.735498 64.65582) (xy 125.699188 64.775518) (xy 125.686928 64.9) (xy 124.336997 64.9) + (xy 124.335 64.76075) (xy 124.17625 64.602) (xy 123.027 64.602) (xy 123.027 64.622) (xy 122.96 64.622) + (xy 122.96 64.328) (xy 123.027 64.328) (xy 123.027 64.348) (xy 124.17625 64.348) (xy 124.296264 64.227986) + (xy 124.35644 64.252911) (xy 124.51776 64.285) (xy 124.68224 64.285) (xy 124.84356 64.252911) (xy 124.995521 64.189967) + (xy 125.132281 64.098587) (xy 125.248587 63.982281) (xy 125.339967 63.845521) (xy 125.402911 63.69356) (xy 125.435 63.53224) + (xy 125.435 63.36776) (xy 125.402911 63.20644) (xy 125.339967 63.054479) (xy 125.248587 62.917719) (xy 125.132281 62.801413) + (xy 124.995521 62.710033) (xy 124.891923 62.667122) (xy 124.513803 62.289002) (xy 124.490001 62.259999) (xy 124.374276 62.165026) + (xy 124.329825 62.141266) (xy 124.325812 62.100518) (xy 124.289502 61.98082) (xy 124.230537 61.870506) (xy 124.151185 61.773815) + (xy 124.054494 61.694463) (xy 123.94418 61.635498) (xy 123.824482 61.599188) (xy 123.7 61.586928) (xy 122.96 61.586928) + (xy 122.96 61.513072) (xy 123.7 61.513072) (xy 123.824482 61.500812) (xy 123.94418 61.464502) (xy 124.054494 61.405537) + (xy 124.151185 61.326185) (xy 124.230537 61.229494) (xy 124.289502 61.11918) (xy 124.325812 60.999482) (xy 124.338072 60.875) + (xy 124.338072 60.836729) (xy 124.891923 60.282878) (xy 124.995521 60.239967) (xy 125.132281 60.148587) (xy 125.248587 60.032281) + (xy 125.339967 59.895521) (xy 125.402911 59.74356) (xy 125.435 59.58224) (xy 125.435 59.41776) (xy 125.402911 59.25644) + (xy 125.339967 59.104479) (xy 125.248587 58.967719) (xy 125.132281 58.851413) (xy 124.995521 58.760033) (xy 124.84356 58.697089) + (xy 124.68224 58.665) (xy 124.51776 58.665) (xy 124.35644 58.697089) (xy 124.204479 58.760033) (xy 124.192372 58.768122) + (xy 124.17625 58.752) (xy 122.827 58.752) (xy 122.827 58.772) (xy 122.573 58.772) (xy 122.573 58.752) + (xy 121.22375 58.752) (xy 121.065 58.91075) (xy 121.061928 59.125) (xy 121.074188 59.249482) (xy 121.110498 59.36918) + (xy 121.169463 59.479494) (xy 121.186292 59.5) (xy 121.169463 59.520506) (xy 121.110498 59.63082) (xy 121.074188 59.750518) + (xy 121.061928 59.875) (xy 121.061928 60.64) (xy 119.938072 60.64) (xy 119.938072 59.875) (xy 119.925812 59.750518) + (xy 119.889502 59.63082) (xy 119.830537 59.520506) (xy 119.813708 59.5) (xy 119.830537 59.479494) (xy 119.889502 59.36918) + (xy 119.925812 59.249482) (xy 119.938072 59.125) (xy 119.938072 58.125) (xy 119.925812 58.000518) (xy 119.889502 57.88082) + (xy 119.830537 57.770506) (xy 119.751185 57.673815) (xy 119.740445 57.665001) (xy 121.259555 57.665001) (xy 121.248815 57.673815) + (xy 121.169463 57.770506) (xy 121.110498 57.88082) (xy 121.074188 58.000518) (xy 121.061928 58.125) (xy 121.065 58.33925) + (xy 121.22375 58.498) (xy 122.573 58.498) (xy 122.573 58.478) (xy 122.827 58.478) (xy 122.827 58.498) + (xy 124.17625 58.498) (xy 124.335 58.33925) (xy 124.338072 58.125) (xy 124.325812 58.000518) (xy 124.289502 57.88082) + (xy 124.230537 57.770506) (xy 124.151185 57.673815) (xy 124.140445 57.665001) (xy 124.377677 57.665001) (xy 124.414999 57.668677) + (xy 124.452321 57.665001) (xy 124.452332 57.665001) (xy 124.563985 57.654004) (xy 124.707246 57.610547) (xy 124.839275 57.539975) + (xy 124.955 57.445002) (xy 124.978803 57.415998) (xy 125.636729 56.758072) (xy 127.015 56.758072) (xy 127.015 57.293997) + (xy 127.129712 57.870692) (xy 127.354727 58.413928) (xy 127.681399 58.902826) (xy 128.097174 59.318601) (xy 128.586072 59.645273) + (xy 129.129308 59.870288) (xy 129.706003 59.985) (xy 130.293997 59.985) (xy 130.870692 59.870288) (xy 131.413928 59.645273) + (xy 131.902826 59.318601) (xy 132.318601 58.902826) (xy 132.645273 58.413928) (xy 132.870288 57.870692) (xy 132.985 57.293997) + (xy 132.985 56.706003) (xy 132.930516 56.432095) + ) + ) + (filled_polygon + (pts + (xy 219.79 77.860444) (xy 219.790001 78.127832) (xy 219.747089 78.23143) (xy 219.715 78.39275) (xy 219.715 78.55723) + (xy 219.747089 78.71855) (xy 219.810033 78.870511) (xy 219.901413 79.007271) (xy 220.017719 79.123577) (xy 220.154479 79.214957) + (xy 220.258078 79.257869) (xy 221.295002 80.294794) (xy 221.295001 81.017667) (xy 221.295001 81.342333) (xy 221.295002 81.342343) + (xy 221.295001 87.842333) (xy 221.295002 87.842343) (xy 221.295002 88.997729) (xy 221.242327 88.975911) (xy 220.936109 88.915) + (xy 220.623891 88.915) (xy 220.317673 88.975911) (xy 220.223303 89.015) (xy 220.05374 89.015) (xy 219.766842 89.072068) + (xy 219.496589 89.18401) (xy 219.253368 89.346525) (xy 219.046525 89.553368) (xy 218.88401 89.796589) (xy 218.772068 90.066842) + (xy 218.715 90.35374) (xy 218.715 90.64626) (xy 218.772068 90.933158) (xy 218.807988 91.019876) (xy 218.498698 91.147988) + (xy 218.276252 91.296622) (xy 218.281817 91.283186) (xy 218.385 90.764449) (xy 218.385 90.235551) (xy 218.281817 89.716814) + (xy 218.079417 89.228175) (xy 217.785576 88.788412) (xy 217.411588 88.414424) (xy 216.971825 88.120583) (xy 216.679503 87.9995) + (xy 217.415123 87.9995) (xy 217.45 88.002935) (xy 217.484877 87.9995) (xy 217.589184 87.989227) (xy 217.72302 87.948628) + (xy 217.846363 87.8827) (xy 217.954475 87.793975) (xy 218.0432 87.685863) (xy 218.109128 87.56252) (xy 218.149727 87.428684) + (xy 218.163435 87.2895) (xy 218.16 87.254623) (xy 218.16 87.01) (xy 218.227002 87.01) (xy 218.227002 86.851252) + (xy 218.38575 87.01) (xy 218.9 87.013072) (xy 219.024482 87.000812) (xy 219.14418 86.964502) (xy 219.254494 86.905537) + (xy 219.351185 86.826185) (xy 219.430537 86.729494) (xy 219.489502 86.61918) (xy 219.525812 86.499482) (xy 219.538072 86.375) + (xy 219.535 86.16075) (xy 219.37625 86.002) (xy 218.227 86.002) (xy 218.227 86.022) (xy 218.16 86.022) + (xy 218.16 85.728) (xy 218.227 85.728) (xy 218.227 85.748) (xy 219.37625 85.748) (xy 219.535 85.58925) + (xy 219.535438 85.558679) (xy 219.66776 85.585) (xy 219.83224 85.585) (xy 219.99356 85.552911) (xy 220.145521 85.489967) + (xy 220.282281 85.398587) (xy 220.398587 85.282281) (xy 220.489967 85.145521) (xy 220.552911 84.99356) (xy 220.585 84.83224) + (xy 220.585 84.66776) (xy 220.552911 84.50644) (xy 220.489967 84.354479) (xy 220.398587 84.217719) (xy 220.282281 84.101413) + (xy 220.145521 84.010033) (xy 220.04363 83.967829) (xy 219.765803 83.690002) (xy 219.742001 83.660999) (xy 219.626276 83.566026) + (xy 219.52704 83.512982) (xy 219.525812 83.500518) (xy 219.489502 83.38082) (xy 219.430537 83.270506) (xy 219.351185 83.173815) + (xy 219.254494 83.094463) (xy 219.14418 83.035498) (xy 219.024482 82.999188) (xy 218.9 82.986928) (xy 218.86 82.986928) + (xy 218.86 80.112312) (xy 218.863676 80.074989) (xy 218.86 80.037666) (xy 218.86 80.037657) (xy 218.849003 79.926004) + (xy 218.805546 79.782743) (xy 218.734974 79.650714) (xy 218.711001 79.621503) (xy 218.663799 79.563986) (xy 218.663795 79.563982) + (xy 218.640001 79.534989) (xy 218.611008 79.511195) (xy 217.473029 78.373217) (xy 217.617244 78.432953) (xy 218.029721 78.515) + (xy 218.450279 78.515) (xy 218.862756 78.432953) (xy 219.251302 78.272012) (xy 219.600983 78.038363) (xy 219.784998 77.854348) + ) + ) + (filled_polygon + (pts + (xy 114.197083 83.55644) (xy 114.164994 83.71776) (xy 114.164994 83.88224) (xy 114.197083 84.04356) (xy 114.260027 84.195521) + (xy 114.351407 84.332281) (xy 114.467713 84.448587) (xy 114.604473 84.539967) (xy 114.756434 84.602911) (xy 114.917754 84.635) + (xy 115.082234 84.635) (xy 115.243554 84.602911) (xy 115.395515 84.539967) (xy 115.532275 84.448587) (xy 115.648581 84.332281) + (xy 115.739961 84.195521) (xy 115.78673 84.082611) (xy 115.85594 84.13941) (xy 116.009686 84.221588) (xy 116.176509 84.272194) + (xy 116.349999 84.289281) (xy 116.523489 84.272194) (xy 116.690313 84.221588) (xy 116.70831 84.211968) (xy 116.710498 84.21918) + (xy 116.769463 84.329494) (xy 116.848815 84.426185) (xy 116.945506 84.505537) (xy 117.05582 84.564502) (xy 117.175518 84.600812) + (xy 117.3 84.613072) (xy 118.04 84.613072) (xy 118.04 84.815123) (xy 118.036565 84.85) (xy 118.050273 84.989184) + (xy 118.090872 85.12302) (xy 118.1568 85.246363) (xy 118.245525 85.354475) (xy 118.338699 85.430941) (xy 118.353637 85.4432) + (xy 118.47698 85.509128) (xy 118.610816 85.549727) (xy 118.75 85.563435) (xy 118.784877 85.56) (xy 119.615858 85.56) + (xy 119.228175 85.720583) (xy 118.788412 86.014424) (xy 118.414424 86.388412) (xy 118.120583 86.828175) (xy 118.087914 86.907046) + (xy 118.032281 86.851413) (xy 117.895521 86.760033) (xy 117.74356 86.697089) (xy 117.58224 86.665) (xy 117.41776 86.665) + (xy 117.25644 86.697089) (xy 117.104479 86.760033) (xy 116.967719 86.851413) (xy 116.902257 86.916875) (xy 116.703411 86.78401) + (xy 116.433158 86.672068) (xy 116.14626 86.615) (xy 115.976697 86.615) (xy 115.882327 86.575911) (xy 115.576109 86.515) + (xy 115.263891 86.515) (xy 114.957673 86.575911) (xy 114.669221 86.695391) (xy 114.409621 86.86885) (xy 114.18885 87.089621) + (xy 114.015391 87.349221) (xy 113.895911 87.637673) (xy 113.835 87.943891) (xy 113.835 88.256109) (xy 113.895911 88.562327) + (xy 114.015391 88.850779) (xy 114.143113 89.041928) (xy 112.35 89.041928) (xy 112.225518 89.054188) (xy 112.10582 89.090498) + (xy 111.995506 89.149463) (xy 111.898815 89.228815) (xy 111.819463 89.325506) (xy 111.760498 89.43582) (xy 111.735542 89.518089) + (xy 111.735009 89.512679) (xy 111.735009 86.062505) (xy 111.738616 86.025883) (xy 111.826413 86.157281) (xy 111.942719 86.273587) + (xy 112.079479 86.364967) (xy 112.23144 86.427911) (xy 112.39276 86.46) (xy 112.55724 86.46) (xy 112.71856 86.427911) + (xy 112.870521 86.364967) (xy 113.007281 86.273587) (xy 113.123587 86.157281) (xy 113.214967 86.020521) (xy 113.277911 85.86856) + (xy 113.31 85.70724) (xy 113.31 85.54276) (xy 113.282 85.401996) (xy 113.282 84.228272) (xy 113.33768 84.211382) + (xy 113.447994 84.152417) (xy 113.544685 84.073065) (xy 113.583493 84.025777) (xy 113.635747 84.009926) (xy 113.767776 83.939354) + (xy 113.883501 83.844381) (xy 113.907303 83.815378) (xy 114.218891 83.50379) + ) + ) + (filled_polygon + (pts + (xy 186.490001 86.335196) (xy 184.964001 87.861198) (xy 184.934998 87.885) (xy 184.889857 87.940005) (xy 184.840025 88.000725) + (xy 184.781908 88.109454) (xy 184.769453 88.132755) (xy 184.725996 88.276016) (xy 184.714999 88.387669) (xy 184.714999 88.387679) + (xy 184.711323 88.425001) (xy 184.714999 88.462323) (xy 184.714999 89.141626) (xy 184.69418 89.130498) (xy 184.574482 89.094188) + (xy 184.45 89.081928) (xy 184.06 89.081928) (xy 184.06 87.181803) (xy 184.466005 86.775799) (xy 184.495002 86.752002) + (xy 184.589975 86.636277) (xy 184.660547 86.504248) (xy 184.704004 86.360987) (xy 184.715001 86.249334) (xy 184.715001 86.249325) + (xy 184.718677 86.212002) (xy 184.715001 86.174679) (xy 184.715001 84.142323) (xy 184.718677 84.105) (xy 184.715001 84.067677) + (xy 184.715001 84.067668) (xy 184.704004 83.956015) (xy 184.660547 83.812754) (xy 184.589975 83.680725) (xy 184.577562 83.6656) + (xy 185.682443 83.6656) (xy 185.78604 83.708511) (xy 185.94736 83.7406) (xy 186.11184 83.7406) (xy 186.27316 83.708511) + (xy 186.425121 83.645567) (xy 186.490001 83.602216) + ) + ) + (filled_polygon + (pts + (xy 124.682049 83.172039) (xy 124.647089 83.25644) (xy 124.615 83.41776) (xy 124.615 83.58224) (xy 124.647089 83.74356) + (xy 124.690001 83.847159) (xy 124.69 84.648385) (xy 123.313997 86.02439) (xy 123.284999 86.048188) (xy 123.261201 86.077186) + (xy 123.2612 86.077187) (xy 123.190025 86.163913) (xy 123.119453 86.295943) (xy 123.097238 86.36918) (xy 123.075997 86.439203) + (xy 123.065844 86.542283) (xy 123.061323 86.588189) (xy 123.065 86.625521) (xy 123.065 87.276213) (xy 122.879417 86.828175) + (xy 122.585576 86.388412) (xy 122.211588 86.014424) (xy 121.771825 85.720583) (xy 121.384142 85.56) (xy 122.215123 85.56) + (xy 122.25 85.563435) (xy 122.284877 85.56) (xy 122.389184 85.549727) (xy 122.52302 85.509128) (xy 122.646363 85.4432) + (xy 122.754475 85.354475) (xy 122.8432 85.246363) (xy 122.909128 85.12302) (xy 122.949727 84.989184) (xy 122.963435 84.85) + (xy 122.96 84.815123) (xy 122.96 84.61) (xy 123.027002 84.61) (xy 123.027002 84.451252) (xy 123.18575 84.61) + (xy 123.7 84.613072) (xy 123.824482 84.600812) (xy 123.94418 84.564502) (xy 124.054494 84.505537) (xy 124.151185 84.426185) + (xy 124.230537 84.329494) (xy 124.289502 84.21918) (xy 124.325812 84.099482) (xy 124.338072 83.975) (xy 124.335 83.76075) + (xy 124.17625 83.602) (xy 123.027 83.602) (xy 123.027 83.622) (xy 122.96 83.622) (xy 122.96 83.328) + (xy 123.027 83.328) (xy 123.027 83.348) (xy 124.17625 83.348) (xy 124.335 83.18925) (xy 124.338072 82.975) + (xy 124.325812 82.850518) (xy 124.310695 82.800685) + ) + ) + (filled_polygon + (pts + (xy 188.019463 75.234494) (xy 188.098815 75.331185) (xy 188.195506 75.410537) (xy 188.30582 75.469502) (xy 188.425518 75.505812) + (xy 188.55 75.518072) (xy 190.85 75.518072) (xy 190.974482 75.505812) (xy 191.09418 75.469502) (xy 191.204494 75.410537) + (xy 191.301185 75.331185) (xy 191.328525 75.297872) (xy 191.529017 75.498364) (xy 191.878698 75.732013) (xy 192.094302 75.821319) + (xy 192.025 76.169721) (xy 192.025 76.590279) (xy 192.107047 77.002756) (xy 192.267988 77.391302) (xy 192.501637 77.740983) + (xy 192.650654 77.89) (xy 191.914802 77.89) (xy 191.632879 77.608077) (xy 191.589967 77.504479) (xy 191.498587 77.367719) + (xy 191.382281 77.251413) (xy 191.245521 77.160033) (xy 191.09356 77.097089) (xy 190.93224 77.065) (xy 190.76776 77.065) + (xy 190.60644 77.097089) (xy 190.454479 77.160033) (xy 190.317719 77.251413) (xy 190.201413 77.367719) (xy 190.110033 77.504479) + (xy 190.047089 77.65644) (xy 190.015 77.81776) (xy 190.015 77.98224) (xy 190.047089 78.14356) (xy 190.110033 78.295521) + (xy 190.201413 78.432281) (xy 190.317719 78.548587) (xy 190.454479 78.639967) (xy 190.558077 78.682879) (xy 191.036201 79.161002) + (xy 191.059999 79.190001) (xy 191.175724 79.284974) (xy 191.307753 79.355546) (xy 191.451014 79.399003) (xy 191.562667 79.41) + (xy 191.562676 79.41) (xy 191.599999 79.413676) (xy 191.637322 79.41) (xy 192.857746 79.41) (xy 192.817122 79.508076) + (xy 191.239003 81.086196) (xy 191.209999 81.109999) (xy 191.165686 81.163995) (xy 191.115026 81.225724) (xy 191.071446 81.307256) + (xy 191.044454 81.357754) (xy 191.000997 81.501015) (xy 190.99 81.612668) (xy 190.99 81.612678) (xy 190.986324 81.65) + (xy 190.99 81.687323) (xy 190.990001 84.752841) (xy 190.947089 84.85644) (xy 190.915 85.01776) (xy 190.915 85.18224) + (xy 190.947089 85.34356) (xy 191.010033 85.495521) (xy 191.101413 85.632281) (xy 191.217719 85.748587) (xy 191.354479 85.839967) + (xy 191.458077 85.882879) (xy 191.961201 86.386002) (xy 191.984999 86.415001) (xy 192.013997 86.438799) (xy 192.100724 86.509974) + (xy 192.232753 86.580546) (xy 192.376014 86.624003) (xy 192.525 86.638677) (xy 192.562333 86.635) (xy 192.918954 86.635) + (xy 192.969463 86.729494) (xy 192.980547 86.743) (xy 189.613072 86.743) (xy 189.613072 86.35) (xy 189.600812 86.225518) + (xy 189.564502 86.10582) (xy 189.505537 85.995506) (xy 189.426185 85.898815) (xy 189.329494 85.819463) (xy 189.21918 85.760498) + (xy 189.099482 85.724188) (xy 188.975 85.711928) (xy 188.025 85.711928) (xy 188.01 85.713405) (xy 188.01 75.21679) + ) + ) + (filled_polygon + (pts + (xy 181.64 73.502843) (xy 181.597089 73.60644) (xy 181.565 73.76776) (xy 181.565 73.93224) (xy 181.597089 74.09356) + (xy 181.660033 74.245521) (xy 181.751413 74.382281) (xy 181.867719 74.498587) (xy 182.004479 74.589967) (xy 182.108077 74.632879) + (xy 182.490001 75.014803) (xy 182.49 81.456867) (xy 182.49 81.456868) (xy 182.490001 83.362668) (xy 182.486324 83.4) + (xy 182.490001 83.437333) (xy 182.500998 83.548986) (xy 182.505641 83.564293) (xy 182.544454 83.692246) (xy 182.615026 83.824276) + (xy 182.684355 83.908753) (xy 182.71 83.940001) (xy 182.738998 83.963799) (xy 182.790199 84.015) (xy 182.523891 84.015) + (xy 182.217673 84.075911) (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) + (xy 181.153368 84.446525) (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) + (xy 180.615 85.74626) (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) + (xy 180.181817 86.383186) (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) + (xy 179.685576 83.888412) (xy 179.311588 83.514424) (xy 178.871825 83.220583) (xy 178.725564 83.16) (xy 179.315123 83.16) + (xy 179.35 83.163435) (xy 179.384877 83.16) (xy 179.396219 83.158883) (xy 179.489184 83.149727) (xy 179.62302 83.109128) + (xy 179.746363 83.0432) (xy 179.854475 82.954475) (xy 179.9432 82.846363) (xy 180.009128 82.72302) (xy 180.049727 82.589184) + (xy 180.06 82.484877) (xy 180.06 82.484876) (xy 180.063435 82.45) (xy 180.06 82.415123) (xy 180.06 82.11) + (xy 180.127002 82.11) (xy 180.127002 81.951252) (xy 180.28575 82.11) (xy 180.8 82.113072) (xy 180.924482 82.100812) + (xy 181.04418 82.064502) (xy 181.154494 82.005537) (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) + (xy 181.425812 81.599482) (xy 181.438072 81.475) (xy 181.435 81.26075) (xy 181.276252 81.102002) (xy 181.354245 81.102002) + (xy 181.35644 81.102911) (xy 181.51776 81.135) (xy 181.68224 81.135) (xy 181.84356 81.102911) (xy 181.995521 81.039967) + (xy 182.132281 80.948587) (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) + (xy 182.435 80.21776) (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) + (xy 181.995521 79.560033) (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.631802 79.465) (xy 181.438072 79.27127) + (xy 181.438072 78.725) (xy 181.425812 78.600518) (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) + (xy 181.154494 78.194463) (xy 181.04418 78.135498) (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.76 78.086928) + (xy 180.76 77.287322) (xy 180.763676 77.249999) (xy 180.76 77.212676) (xy 180.76 77.212667) (xy 180.749003 77.101014) + (xy 180.705546 76.957753) (xy 180.634974 76.825724) (xy 180.540001 76.709999) (xy 180.511003 76.686201) (xy 179.074999 75.250198) + (xy 179.074999 73.436132) (xy 179.128698 73.472012) (xy 179.517244 73.632953) (xy 179.929721 73.715) (xy 180.350279 73.715) + (xy 180.762756 73.632953) (xy 181.151302 73.472012) (xy 181.500983 73.238363) (xy 181.640001 73.099345) + ) + ) + (filled_polygon + (pts + (xy 143.54 73.552843) (xy 143.497089 73.65644) (xy 143.465 73.81776) (xy 143.465 73.98224) (xy 143.497089 74.14356) + (xy 143.560033 74.295521) (xy 143.651413 74.432281) (xy 143.767719 74.548587) (xy 143.904479 74.639967) (xy 144.008078 74.682879) + (xy 145.095001 75.769803) (xy 145.095002 84.097729) (xy 145.042327 84.075911) (xy 144.736109 84.015) (xy 144.423891 84.015) + (xy 144.117673 84.075911) (xy 144.023303 84.115) (xy 143.85374 84.115) (xy 143.566842 84.172068) (xy 143.296589 84.28401) + (xy 143.053368 84.446525) (xy 142.846525 84.653368) (xy 142.68401 84.896589) (xy 142.572068 85.166842) (xy 142.515 85.45374) + (xy 142.515 85.74626) (xy 142.572068 86.033158) (xy 142.607988 86.119876) (xy 142.298698 86.247988) (xy 142.076252 86.396622) + (xy 142.081817 86.383186) (xy 142.185 85.864449) (xy 142.185 85.335551) (xy 142.081817 84.816814) (xy 141.879417 84.328175) + (xy 141.585576 83.888412) (xy 141.211588 83.514424) (xy 140.771825 83.220583) (xy 140.625564 83.16) (xy 141.215123 83.16) + (xy 141.25 83.163435) (xy 141.284877 83.16) (xy 141.296219 83.158883) (xy 141.389184 83.149727) (xy 141.52302 83.109128) + (xy 141.646363 83.0432) (xy 141.754475 82.954475) (xy 141.8432 82.846363) (xy 141.909128 82.72302) (xy 141.949727 82.589184) + (xy 141.96 82.484877) (xy 141.96 82.484876) (xy 141.963435 82.45) (xy 141.96 82.415123) (xy 141.96 82.11) + (xy 142.027002 82.11) (xy 142.027002 81.951252) (xy 142.18575 82.11) (xy 142.7 82.113072) (xy 142.824482 82.100812) + (xy 142.94418 82.064502) (xy 143.054494 82.005537) (xy 143.151185 81.926185) (xy 143.230537 81.829494) (xy 143.289502 81.71918) + (xy 143.325812 81.599482) (xy 143.338072 81.475) (xy 143.335 81.26075) (xy 143.17625 81.102) (xy 142.027 81.102) + (xy 142.027 81.122) (xy 141.96 81.122) (xy 141.96 80.828) (xy 142.027 80.828) (xy 142.027 80.848) + (xy 143.17625 80.848) (xy 143.335 80.68925) (xy 143.335227 80.673414) (xy 143.40644 80.702911) (xy 143.56776 80.735) + (xy 143.73224 80.735) (xy 143.89356 80.702911) (xy 144.045521 80.639967) (xy 144.182281 80.548587) (xy 144.298587 80.432281) + (xy 144.389967 80.295521) (xy 144.452911 80.14356) (xy 144.485 79.98224) (xy 144.485 79.81776) (xy 144.452911 79.65644) + (xy 144.403303 79.536676) (xy 144.399003 79.493014) (xy 144.355546 79.349753) (xy 144.284974 79.217724) (xy 144.262222 79.190001) + (xy 144.213799 79.130996) (xy 144.213795 79.130992) (xy 144.190001 79.101999) (xy 144.161009 79.078206) (xy 143.696803 78.614002) + (xy 143.673001 78.584999) (xy 143.557276 78.490026) (xy 143.425247 78.419454) (xy 143.281986 78.375997) (xy 143.230776 78.370953) + (xy 143.230537 78.370506) (xy 143.151185 78.273815) (xy 143.054494 78.194463) (xy 142.94418 78.135498) (xy 142.824482 78.099188) + (xy 142.7 78.086928) (xy 142.66 78.086928) (xy 142.66 76.687322) (xy 142.663676 76.649999) (xy 142.66 76.612676) + (xy 142.66 76.612667) (xy 142.649003 76.501014) (xy 142.605546 76.357753) (xy 142.534974 76.225724) (xy 142.440001 76.109999) + (xy 142.411004 76.086202) (xy 140.974999 74.650198) (xy 140.974999 73.536132) (xy 141.028698 73.572012) (xy 141.417244 73.732953) + (xy 141.829721 73.815) (xy 142.250279 73.815) (xy 142.662756 73.732953) (xy 143.051302 73.572012) (xy 143.400983 73.338363) + (xy 143.540001 73.199345) + ) + ) + (filled_polygon + (pts + (xy 187.149188 65.774482) (xy 187.185498 65.89418) (xy 187.244463 66.004494) (xy 187.323815 66.101185) (xy 187.420506 66.180537) + (xy 187.53082 66.239502) (xy 187.650518 66.275812) (xy 187.687113 66.279416) (xy 187.573723 66.340025) (xy 187.457998 66.434998) + (xy 187.4342 66.463997) (xy 186.990756 66.907441) (xy 186.957753 66.917452) (xy 186.825724 66.988024) (xy 186.709999 67.082997) + (xy 186.615026 67.198723) (xy 186.544454 67.330752) (xy 186.500997 67.474013) (xy 186.49 67.585666) (xy 186.49 67.685676) + (xy 186.486324 67.722998) (xy 186.49 67.76032) (xy 186.490001 82.208984) (xy 186.425121 82.165633) (xy 186.27316 82.102689) + (xy 186.11184 82.0706) (xy 185.94736 82.0706) (xy 185.78604 82.102689) (xy 185.682443 82.1456) (xy 184.497157 82.1456) + (xy 184.39356 82.102689) (xy 184.23224 82.0706) (xy 184.06776 82.0706) (xy 184.01 82.082089) (xy 184.01 74.737333) + (xy 184.013677 74.7) (xy 183.999003 74.551014) (xy 183.955546 74.407753) (xy 183.884974 74.275724) (xy 183.842826 74.224366) + (xy 183.790001 74.159999) (xy 183.761003 74.136201) (xy 183.182879 73.558077) (xy 183.16 73.502843) (xy 183.16 73.258072) + (xy 184.45 73.258072) (xy 184.574482 73.245812) (xy 184.69418 73.209502) (xy 184.804494 73.150537) (xy 184.901185 73.071185) + (xy 184.980537 72.974494) (xy 185.039502 72.86418) (xy 185.075812 72.744482) (xy 185.088072 72.62) (xy 185.088072 70.62) + (xy 185.075812 70.495518) (xy 185.039502 70.37582) (xy 184.980537 70.265506) (xy 184.901185 70.168815) (xy 184.804494 70.089463) + (xy 184.715001 70.041627) (xy 184.715001 65.76) (xy 187.147762 65.76) + ) + ) + (filled_polygon + (pts + (xy 180.127 80.848) (xy 180.147 80.848) (xy 180.147 81.102) (xy 180.127 81.102) (xy 180.127 81.122) + (xy 180.06 81.122) (xy 180.06 80.828) (xy 180.127 80.828) + ) + ) + (filled_polygon + (pts + (xy 105.381186 68.948002) (xy 105.410184 68.9718) (xy 105.49691 69.042975) (xy 105.588378 69.091866) (xy 105.62894 69.113547) + (xy 105.772201 69.157004) (xy 105.883854 69.168001) (xy 105.883864 69.168001) (xy 105.921187 69.171677) (xy 105.95851 69.168001) + (xy 106.023 69.168001) (xy 106.023 69.307592) (xy 106.076686 69.57749) (xy 106.181995 69.831727) (xy 106.33488 70.060535) + (xy 106.529465 70.25512) (xy 106.758273 70.408005) (xy 107.01251 70.513314) (xy 107.282408 70.567) (xy 107.334478 70.567) + (xy 107.375501 70.773235) (xy 107.48081 71.027472) (xy 107.633695 71.25628) (xy 107.82828 71.450865) (xy 108.057088 71.60375) + (xy 108.311325 71.709059) (xy 108.581223 71.762745) (xy 108.856407 71.762745) (xy 108.990003 71.736171) (xy 108.990003 74.693303) + (xy 108.90618 74.648498) (xy 108.786482 74.612188) (xy 108.662 74.599928) (xy 108.18575 74.603) (xy 108.027 74.76175) + (xy 108.027 75.873) (xy 108.047 75.873) (xy 108.047 76.127) (xy 108.027 76.127) (xy 108.027 76.147) + (xy 107.773 76.147) (xy 107.773 76.127) (xy 106.66175 76.127) (xy 106.503 76.28575) (xy 106.499928 76.762) + (xy 106.512188 76.886482) (xy 106.548498 77.00618) (xy 106.607463 77.116494) (xy 106.686815 77.213185) (xy 106.783506 77.292537) + (xy 106.797468 77.3) (xy 106.783506 77.307463) (xy 106.686815 77.386815) (xy 106.607463 77.483506) (xy 106.548498 77.59382) + (xy 106.512188 77.713518) (xy 106.499928 77.838) (xy 106.499928 79.362) (xy 106.512188 79.486482) (xy 106.548498 79.60618) + (xy 106.607463 79.716494) (xy 106.686815 79.813185) (xy 106.731674 79.85) (xy 106.686815 79.886815) (xy 106.664989 79.91341) + (xy 105.385 78.633422) (xy 105.385 76.543477) (xy 105.389282 76.5) (xy 105.372195 76.32651) (xy 105.321589 76.159687) + (xy 105.239411 76.005941) (xy 105.128817 75.871183) (xy 104.994059 75.760589) (xy 104.988077 75.757392) (xy 105.170057 75.635797) + (xy 105.355797 75.450057) (xy 105.497488 75.238) (xy 106.499928 75.238) (xy 106.503 75.71425) (xy 106.66175 75.873) + (xy 107.773 75.873) (xy 107.773 74.76175) (xy 107.61425 74.603) (xy 107.138 74.599928) (xy 107.013518 74.612188) + (xy 106.89382 74.648498) (xy 106.783506 74.707463) (xy 106.686815 74.786815) (xy 106.607463 74.883506) (xy 106.548498 74.99382) + (xy 106.512188 75.113518) (xy 106.499928 75.238) (xy 105.497488 75.238) (xy 105.501732 75.231649) (xy 105.602254 74.988968) + (xy 105.6535 74.731338) (xy 105.6535 74.468662) (xy 105.602254 74.211032) (xy 105.501732 73.968351) (xy 105.355797 73.749943) + (xy 105.170057 73.564203) (xy 105.06 73.490666) (xy 105.06 70.724272) (xy 105.11568 70.707382) (xy 105.225994 70.648417) + (xy 105.322685 70.569065) (xy 105.402037 70.472374) (xy 105.461002 70.36206) (xy 105.497312 70.242362) (xy 105.509572 70.11788) + (xy 105.509572 69.48288) (xy 105.497312 69.358398) (xy 105.479597 69.3) (xy 105.497312 69.241602) (xy 105.509572 69.11712) + (xy 105.5065 69.08537) (xy 105.347752 68.926622) (xy 105.36364 68.926622) + ) + ) + (filled_polygon + (pts + (xy 162.64 71.092843) (xy 162.597089 71.19644) (xy 162.565 71.35776) (xy 162.565 71.52224) (xy 162.597089 71.68356) + (xy 162.660033 71.835521) (xy 162.751413 71.972281) (xy 162.867719 72.088587) (xy 163.004479 72.179967) (xy 163.108078 72.222879) + (xy 164.240001 73.354803) (xy 164.24 78.192843) (xy 164.197089 78.29644) (xy 164.165 78.45776) (xy 164.165 78.62224) + (xy 164.197089 78.78356) (xy 164.260033 78.935521) (xy 164.351413 79.072281) (xy 164.467719 79.188587) (xy 164.604479 79.279967) + (xy 164.75644 79.342911) (xy 164.830733 79.357689) (xy 164.633422 79.555) (xy 162.203889 79.555) (xy 162.251185 79.516185) + (xy 162.330537 79.419494) (xy 162.389502 79.30918) (xy 162.425812 79.189482) (xy 162.438072 79.065) (xy 162.435 78.85075) + (xy 162.27625 78.692) (xy 161.127 78.692) (xy 161.127 78.712) (xy 161.06 78.712) (xy 161.06 78.418) + (xy 161.127 78.418) (xy 161.127 78.438) (xy 162.27625 78.438) (xy 162.435 78.27925) (xy 162.435248 78.261963) + (xy 162.565014 78.208212) (xy 162.701774 78.116832) (xy 162.81808 78.000526) (xy 162.90946 77.863766) (xy 162.972404 77.711805) + (xy 163.004493 77.550485) (xy 163.004493 77.386005) (xy 162.972404 77.224685) (xy 162.90946 77.072724) (xy 162.81808 76.935964) + (xy 162.701774 76.819658) (xy 162.565014 76.728278) (xy 162.438072 76.675697) (xy 162.438072 76.315) (xy 162.425812 76.190518) + (xy 162.389502 76.07082) (xy 162.330537 75.960506) (xy 162.251185 75.863815) (xy 162.154494 75.784463) (xy 162.04418 75.725498) + (xy 161.924482 75.689188) (xy 161.8 75.676928) (xy 161.06 75.676928) (xy 161.06 75.491077) (xy 161.063435 75.4562) + (xy 161.049727 75.317016) (xy 161.009128 75.18318) (xy 160.9432 75.059837) (xy 160.854475 74.951725) (xy 160.746363 74.863) + (xy 160.62302 74.797072) (xy 160.489184 74.756473) (xy 160.384877 74.7462) (xy 160.35 74.742765) (xy 160.315123 74.7462) + (xy 157.226914 74.7462) (xy 159.826002 72.147112) (xy 159.855 72.123314) (xy 159.90615 72.060988) (xy 159.949973 72.00759) + (xy 160.020545 71.87556) (xy 160.034365 71.830001) (xy 160.064002 71.732299) (xy 160.074999 71.620646) (xy 160.074999 71.620637) + (xy 160.078675 71.583314) (xy 160.074999 71.545991) (xy 160.074999 71.026132) (xy 160.128698 71.062012) (xy 160.517244 71.222953) + (xy 160.929721 71.305) (xy 161.350279 71.305) (xy 161.762756 71.222953) (xy 162.151302 71.062012) (xy 162.500983 70.828363) + (xy 162.640001 70.689345) + ) + ) + (filled_polygon + (pts + (xy 164.915003 56.707757) (xy 164.915003 56.872237) (xy 164.947092 57.033557) (xy 165.010036 57.185518) (xy 165.101416 57.322278) + (xy 165.217722 57.438584) (xy 165.354482 57.529964) (xy 165.458081 57.572876) (xy 167.857806 59.972602) (xy 167.881605 60.001601) + (xy 167.99733 60.096574) (xy 168.129359 60.167146) (xy 168.27262 60.210603) (xy 168.384273 60.2216) (xy 168.384282 60.2216) + (xy 168.421605 60.225276) (xy 168.458928 60.2216) (xy 169.933613 60.2216) (xy 170.752013 61.04) (xy 170.69276 61.04) + (xy 170.588731 61.060693) (xy 170.564502 60.98082) (xy 170.505537 60.870506) (xy 170.426185 60.773815) (xy 170.329494 60.694463) + (xy 170.21918 60.635498) (xy 170.099482 60.599188) (xy 169.975 60.586928) (xy 169.025 60.586928) (xy 168.900518 60.599188) + (xy 168.78082 60.635498) (xy 168.670506 60.694463) (xy 168.573815 60.773815) (xy 168.494463 60.870506) (xy 168.435498 60.98082) + (xy 168.399188 61.100518) (xy 168.386928 61.225) (xy 168.386928 62.525) (xy 168.399188 62.649482) (xy 168.435498 62.76918) + (xy 168.494463 62.879494) (xy 168.573815 62.976185) (xy 168.670506 63.055537) (xy 168.78082 63.114502) (xy 168.900518 63.150812) + (xy 169.025 63.163072) (xy 169.975 63.163072) (xy 170.099482 63.150812) (xy 170.21918 63.114502) (xy 170.329494 63.055537) + (xy 170.426185 62.976185) (xy 170.505537 62.879494) (xy 170.564502 62.76918) (xy 170.588731 62.689307) (xy 170.69276 62.71) + (xy 170.85724 62.71) (xy 171.01856 62.677911) (xy 171.122157 62.635) (xy 171.410199 62.635) (xy 173.411199 64.636001) + (xy 173.434998 64.665) (xy 173.463996 64.688798) (xy 173.550722 64.759973) (xy 173.656502 64.816514) (xy 173.682752 64.830545) + (xy 173.826013 64.874002) (xy 173.937666 64.884999) (xy 173.937675 64.884999) (xy 173.974998 64.888675) (xy 174.012321 64.884999) + (xy 174.195386 64.884999) (xy 174.197089 64.89356) (xy 174.240001 64.997159) (xy 174.240001 65.539894) (xy 174.046632 65.346525) + (xy 173.803411 65.18401) (xy 173.533158 65.072068) (xy 173.24626 65.015) (xy 173.076697 65.015) (xy 172.982327 64.975911) + (xy 172.676109 64.915) (xy 172.363891 64.915) (xy 172.057673 64.975911) (xy 171.769221 65.095391) (xy 171.509621 65.26885) + (xy 171.28885 65.489621) (xy 171.115391 65.749221) (xy 171.083084 65.827216) (xy 171.019781 65.763913) (xy 170.883021 65.672533) + (xy 170.779423 65.629622) (xy 170.613072 65.46327) (xy 170.613072 64.775) (xy 170.600812 64.650518) (xy 170.564502 64.53082) + (xy 170.505537 64.420506) (xy 170.426185 64.323815) (xy 170.329494 64.244463) (xy 170.21918 64.185498) (xy 170.099482 64.149188) + (xy 169.975 64.136928) (xy 169.025 64.136928) (xy 168.900518 64.149188) (xy 168.78082 64.185498) (xy 168.670506 64.244463) + (xy 168.573815 64.323815) (xy 168.494463 64.420506) (xy 168.435498 64.53082) (xy 168.399188 64.650518) (xy 168.386928 64.775) + (xy 168.386928 66.075) (xy 168.399188 66.199482) (xy 168.435498 66.31918) (xy 168.494463 66.429494) (xy 168.573815 66.526185) + (xy 168.670506 66.605537) (xy 168.78082 66.664502) (xy 168.900518 66.700812) (xy 169.025 66.713072) (xy 169.708204 66.713072) + (xy 169.747533 66.808021) (xy 169.838913 66.944781) (xy 169.840001 66.945869) (xy 169.840001 67.441928) (xy 169.45 67.441928) + (xy 169.325518 67.454188) (xy 169.20582 67.490498) (xy 169.095506 67.549463) (xy 168.998815 67.628815) (xy 168.919463 67.725506) + (xy 168.860498 67.83582) (xy 168.824188 67.955518) (xy 168.811928 68.08) (xy 168.811928 70.08) (xy 168.824188 70.204482) + (xy 168.860498 70.32418) (xy 168.919463 70.434494) (xy 168.998815 70.531185) (xy 169.095506 70.610537) (xy 169.0962 70.610908) + (xy 169.065 70.76776) (xy 169.065 70.93224) (xy 169.097089 71.09356) (xy 169.160033 71.245521) (xy 169.251413 71.382281) + (xy 169.367719 71.498587) (xy 169.504479 71.589967) (xy 169.65644 71.652911) (xy 169.81776 71.685) (xy 169.98224 71.685) + (xy 170.14356 71.652911) (xy 170.295521 71.589967) (xy 170.432281 71.498587) (xy 170.548587 71.382281) (xy 170.639967 71.245521) + (xy 170.702911 71.09356) (xy 170.735 70.93224) (xy 170.735 70.76776) (xy 170.725116 70.718072) (xy 171.75 70.718072) + (xy 171.874482 70.705812) (xy 171.99418 70.669502) (xy 172.104494 70.610537) (xy 172.201185 70.531185) (xy 172.228525 70.497872) + (xy 172.429017 70.698364) (xy 172.778698 70.932013) (xy 172.994302 71.021319) (xy 172.925 71.369721) (xy 172.925 71.790279) + (xy 173.007047 72.202756) (xy 173.167988 72.591302) (xy 173.401637 72.940983) (xy 173.699017 73.238363) (xy 174.048698 73.472012) + (xy 174.437244 73.632953) (xy 174.849721 73.715) (xy 175.270279 73.715) (xy 175.682756 73.632953) (xy 176.071302 73.472012) + (xy 176.420983 73.238363) (xy 176.718363 72.940983) (xy 176.952012 72.591302) (xy 177.112953 72.202756) (xy 177.195 71.790279) + (xy 177.195 71.369721) (xy 177.112953 70.957244) (xy 176.952012 70.568698) (xy 176.718363 70.219017) (xy 176.420983 69.921637) + (xy 176.071302 69.687988) (xy 175.855698 69.598682) (xy 175.897704 69.387507) (xy 177.555 71.044804) (xy 177.554999 75.527676) + (xy 177.551323 75.564999) (xy 177.554999 75.602321) (xy 177.554999 75.602331) (xy 177.565996 75.713984) (xy 177.591781 75.798986) + (xy 177.609453 75.857245) (xy 177.680025 75.989275) (xy 177.69865 76.011969) (xy 177.774998 76.105) (xy 177.804002 76.128803) + (xy 178.915198 77.24) (xy 175.884877 77.24) (xy 175.85 77.236565) (xy 175.815123 77.24) (xy 175.710816 77.250273) + (xy 175.57698 77.290872) (xy 175.453637 77.3568) (xy 175.345525 77.445525) (xy 175.2568 77.553637) (xy 175.190872 77.67698) + (xy 175.150273 77.810816) (xy 175.136565 77.95) (xy 175.140001 77.984887) (xy 175.140001 78.086928) (xy 174.4 78.086928) + (xy 174.275518 78.099188) (xy 174.15582 78.135498) (xy 174.045506 78.194463) (xy 173.948815 78.273815) (xy 173.894499 78.34) + (xy 172.741579 78.34) (xy 171.921534 77.519956) (xy 171.893817 77.486183) (xy 171.759059 77.375589) (xy 171.605313 77.293411) + (xy 171.43849 77.242805) (xy 171.308477 77.23) (xy 171.308469 77.23) (xy 171.265 77.225719) (xy 171.221531 77.23) + (xy 167.368469 77.23) (xy 167.325 77.225719) (xy 167.281531 77.23) (xy 167.281523 77.23) (xy 167.15151 77.242805) + (xy 166.984686 77.293411) (xy 166.830941 77.375589) (xy 166.729953 77.458468) (xy 166.729951 77.45847) (xy 166.696183 77.486183) + (xy 166.66847 77.519951) (xy 165.817689 78.370732) (xy 165.802911 78.29644) (xy 165.76 78.192843) (xy 165.76 73.077325) + (xy 165.763676 73.04) (xy 165.76 73.002675) (xy 165.76 73.002667) (xy 165.749003 72.891014) (xy 165.705546 72.747753) + (xy 165.634974 72.615724) (xy 165.540001 72.499999) (xy 165.511003 72.476201) (xy 164.182879 71.148078) (xy 164.16 71.092843) + (xy 164.16 70.848072) (xy 165.45 70.848072) (xy 165.574482 70.835812) (xy 165.69418 70.799502) (xy 165.804494 70.740537) + (xy 165.901185 70.661185) (xy 165.980537 70.564494) (xy 166.039502 70.45418) (xy 166.075812 70.334482) (xy 166.088072 70.21) + (xy 166.088072 68.21) (xy 166.075812 68.085518) (xy 166.039502 67.96582) (xy 165.980537 67.855506) (xy 165.901185 67.758815) + (xy 165.804494 67.679463) (xy 165.69418 67.620498) (xy 165.574482 67.584188) (xy 165.45 67.571928) (xy 164.330748 67.571928) + (xy 164.462953 67.252756) (xy 164.545 66.840279) (xy 164.545 66.419721) (xy 164.462953 66.007244) (xy 164.302012 65.618698) + (xy 164.264985 65.563283) (xy 164.430779 65.494609) (xy 164.690379 65.32115) (xy 164.91115 65.100379) (xy 165.084609 64.840779) + (xy 165.204089 64.552327) (xy 165.265 64.246109) (xy 165.265 63.933891) (xy 165.204089 63.627673) (xy 165.084609 63.339221) + (xy 164.91115 63.079621) (xy 164.690379 62.85885) (xy 164.430779 62.685391) (xy 164.142327 62.565911) (xy 163.836109 62.505) + (xy 163.523891 62.505) (xy 163.217673 62.565911) (xy 163.123303 62.605) (xy 162.95374 62.605) (xy 162.666842 62.662068) + (xy 162.396589 62.77401) (xy 162.293999 62.842558) (xy 162.293999 62.470802) (xy 164.061003 60.703799) (xy 164.090001 60.680001) + (xy 164.129778 60.631533) (xy 164.184974 60.564277) (xy 164.255546 60.432247) (xy 164.263204 60.407) (xy 164.299003 60.288986) + (xy 164.31 60.177333) (xy 164.31 60.177323) (xy 164.313676 60.14) (xy 164.31 60.102677) (xy 164.31 59.177322) + (xy 164.313676 59.139999) (xy 164.31 59.102676) (xy 164.31 59.102667) (xy 164.299003 58.991014) (xy 164.255546 58.847753) + (xy 164.184974 58.715724) (xy 164.090001 58.599999) (xy 164.061003 58.576201) (xy 163.713803 58.229002) (xy 163.690001 58.199999) + (xy 163.574276 58.105026) (xy 163.442247 58.034454) (xy 163.298986 57.990997) (xy 163.187333 57.98) (xy 163.187322 57.98) + (xy 163.15 57.976324) (xy 163.112678 57.98) (xy 162.647157 57.98) (xy 162.591923 57.957122) (xy 162.438072 57.80327) + (xy 162.438072 57.215) (xy 162.425812 57.090518) (xy 162.389502 56.97082) (xy 162.330537 56.860506) (xy 162.251185 56.763815) + (xy 162.234351 56.75) (xy 164.512678 56.75) (xy 164.55 56.753676) (xy 164.587322 56.75) (xy 164.587333 56.75) + (xy 164.698986 56.739003) (xy 164.842247 56.695546) (xy 164.926377 56.650577) + ) + ) + (filled_polygon + (pts + (xy 131.740001 67.414803) (xy 131.740001 67.541928) (xy 131.35 67.541928) (xy 131.225518 67.554188) (xy 131.10582 67.590498) + (xy 130.995506 67.649463) (xy 130.898815 67.728815) (xy 130.819463 67.825506) (xy 130.760498 67.93582) (xy 130.724188 68.055518) + (xy 130.711928 68.18) (xy 130.711928 70.18) (xy 130.724188 70.304482) (xy 130.760498 70.42418) (xy 130.819463 70.534494) + (xy 130.898815 70.631185) (xy 130.987616 70.704062) (xy 130.965 70.81776) (xy 130.965 70.98224) (xy 130.997089 71.14356) + (xy 131.060033 71.295521) (xy 131.151413 71.432281) (xy 131.267719 71.548587) (xy 131.404479 71.639967) (xy 131.55644 71.702911) + (xy 131.71776 71.735) (xy 131.88224 71.735) (xy 132.04356 71.702911) (xy 132.195521 71.639967) (xy 132.332281 71.548587) + (xy 132.448587 71.432281) (xy 132.539967 71.295521) (xy 132.602911 71.14356) (xy 132.635 70.98224) (xy 132.635 70.818072) + (xy 133.65 70.818072) (xy 133.774482 70.805812) (xy 133.89418 70.769502) (xy 134.004494 70.710537) (xy 134.101185 70.631185) + (xy 134.128525 70.597872) (xy 134.329017 70.798364) (xy 134.678698 71.032013) (xy 134.894302 71.121319) (xy 134.825 71.469721) + (xy 134.825 71.890279) (xy 134.907047 72.302756) (xy 135.067988 72.691302) (xy 135.301637 73.040983) (xy 135.599017 73.338363) + (xy 135.948698 73.572012) (xy 136.337244 73.732953) (xy 136.749721 73.815) (xy 137.170279 73.815) (xy 137.582756 73.732953) + (xy 137.971302 73.572012) (xy 138.320983 73.338363) (xy 138.618363 73.040983) (xy 138.852012 72.691302) (xy 139.012953 72.302756) + (xy 139.095 71.890279) (xy 139.095 71.469721) (xy 139.012953 71.057244) (xy 138.852012 70.668698) (xy 138.618363 70.319017) + (xy 138.320983 70.021637) (xy 137.971302 69.787988) (xy 137.755698 69.698682) (xy 137.814295 69.404098) (xy 139.454999 71.044803) + (xy 139.455 74.927667) (xy 139.451323 74.964999) (xy 139.455 75.002332) (xy 139.465997 75.113985) (xy 139.473889 75.140001) + (xy 139.509453 75.257245) (xy 139.580025 75.389275) (xy 139.647879 75.471954) (xy 139.674999 75.505) (xy 139.703997 75.528798) + (xy 141.14 76.964802) (xy 141.14 77.24) (xy 137.784877 77.24) (xy 137.75 77.236565) (xy 137.715123 77.24) + (xy 137.610816 77.250273) (xy 137.47698 77.290872) (xy 137.353637 77.3568) (xy 137.245525 77.445525) (xy 137.1568 77.553637) + (xy 137.090872 77.67698) (xy 137.050273 77.810816) (xy 137.036565 77.95) (xy 137.040001 77.984887) (xy 137.040001 78.086928) + (xy 136.3 78.086928) (xy 136.175518 78.099188) (xy 136.05582 78.135498) (xy 135.945506 78.194463) (xy 135.890019 78.24) + (xy 133.118476 78.24) (xy 133.075 78.235718) (xy 133.031523 78.24) (xy 132.928705 78.250127) (xy 130.335 75.656422) + (xy 130.335 69.105471) (xy 130.339281 69.062002) (xy 130.335 69.018533) (xy 130.335 69.018525) (xy 130.322195 68.888512) + (xy 130.308937 68.844808) (xy 130.271589 68.721688) (xy 130.189411 68.567943) (xy 130.106532 68.466955) (xy 130.10653 68.466953) + (xy 130.078817 68.433185) (xy 130.045049 68.405472) (xy 129.734999 68.095423) (xy 129.734999 66.863072) (xy 130.275 66.863072) + (xy 130.399482 66.850812) (xy 130.51918 66.814502) (xy 130.629494 66.755537) (xy 130.726185 66.676185) (xy 130.805537 66.579494) + (xy 130.840076 66.514877) + ) + ) + (filled_polygon + (pts + (xy 216.979017 59.138363) (xy 217.328698 59.372012) (xy 217.717244 59.532953) (xy 218.129721 59.615) (xy 218.550279 59.615) + (xy 218.962756 59.532953) (xy 219.351302 59.372012) (xy 219.700983 59.138363) (xy 219.74 59.099346) (xy 219.74 59.402843) + (xy 219.697089 59.50644) (xy 219.665 59.66776) (xy 219.665 59.83224) (xy 219.697089 59.99356) (xy 219.760033 60.145521) + (xy 219.851413 60.282281) (xy 219.967719 60.398587) (xy 220.104479 60.489967) (xy 220.208078 60.532879) (xy 221.295002 61.619804) + (xy 221.295001 69.797729) (xy 221.242327 69.775911) (xy 220.936109 69.715) (xy 220.623891 69.715) (xy 220.317673 69.775911) + (xy 220.223303 69.815) (xy 220.05374 69.815) (xy 219.766842 69.872068) (xy 219.496589 69.98401) (xy 219.253368 70.146525) + (xy 219.046525 70.353368) (xy 218.88401 70.596589) (xy 218.772068 70.866842) (xy 218.715 71.15374) (xy 218.715 71.44626) + (xy 218.772068 71.733158) (xy 218.807988 71.819876) (xy 218.498698 71.947988) (xy 218.276252 72.096622) (xy 218.281817 72.083186) + (xy 218.385 71.564449) (xy 218.385 71.035551) (xy 218.281817 70.516814) (xy 218.079417 70.028175) (xy 217.785576 69.588412) + (xy 217.411588 69.214424) (xy 216.971825 68.920583) (xy 216.5262 68.736) (xy 217.415123 68.736) (xy 217.45 68.739435) + (xy 217.484877 68.736) (xy 217.589184 68.725727) (xy 217.72302 68.685128) (xy 217.846363 68.6192) (xy 217.954475 68.530475) + (xy 218.0432 68.422363) (xy 218.109128 68.29902) (xy 218.149727 68.165184) (xy 218.163435 68.026) (xy 218.16 67.991123) + (xy 218.16 67.81) (xy 218.227002 67.81) (xy 218.227002 67.651252) (xy 218.38575 67.81) (xy 218.9 67.813072) + (xy 219.024482 67.800812) (xy 219.14418 67.764502) (xy 219.254494 67.705537) (xy 219.351185 67.626185) (xy 219.430537 67.529494) + (xy 219.489502 67.41918) (xy 219.525812 67.299482) (xy 219.538072 67.175) (xy 219.535 66.96075) (xy 219.376252 66.802002) + (xy 219.535 66.802002) (xy 219.535 66.6845) (xy 219.60174 66.6845) (xy 219.76306 66.652411) (xy 219.915021 66.589467) + (xy 220.051781 66.498087) (xy 220.168087 66.381781) (xy 220.259467 66.245021) (xy 220.322411 66.09306) (xy 220.3545 65.93174) + (xy 220.3545 65.76726) (xy 220.322411 65.60594) (xy 220.2795 65.502343) (xy 220.2795 65.251823) (xy 220.283176 65.2145) + (xy 220.2795 65.177177) (xy 220.2795 65.177167) (xy 220.268503 65.065514) (xy 220.225046 64.922253) (xy 220.154474 64.790224) + (xy 220.059501 64.674499) (xy 220.030498 64.650697) (xy 219.793804 64.414003) (xy 219.770001 64.384999) (xy 219.654276 64.290026) + (xy 219.522247 64.219454) (xy 219.499091 64.21243) (xy 219.489502 64.18082) (xy 219.430537 64.070506) (xy 219.351185 63.973815) + (xy 219.254494 63.894463) (xy 219.14418 63.835498) (xy 219.024482 63.799188) (xy 218.9 63.786928) (xy 218.86 63.786928) + (xy 218.86 63.337322) (xy 218.863676 63.299999) (xy 218.86 63.262676) (xy 218.86 63.262667) (xy 218.849003 63.151014) + (xy 218.805546 63.007753) (xy 218.734974 62.875724) (xy 218.640001 62.759999) (xy 218.611004 62.736202) (xy 216.8488 60.973999) + (xy 216.8488 59.008146) + ) + ) + (filled_polygon + (pts + (xy 114.04347 62.095049) (xy 114.071183 62.128817) (xy 114.104951 62.15653) (xy 114.104953 62.156532) (xy 114.126222 62.173987) + (xy 114.205941 62.239411) (xy 114.359687 62.321589) (xy 114.52651 62.372195) (xy 114.656523 62.385) (xy 114.656533 62.385) + (xy 114.699999 62.389281) (xy 114.743466 62.385) (xy 115.433422 62.385) (xy 116.183777 63.135355) (xy 116.101413 63.217719) + (xy 116.010033 63.354479) (xy 115.947089 63.50644) (xy 115.915 63.66776) (xy 115.915 63.83224) (xy 115.947089 63.99356) + (xy 115.99 64.097157) (xy 115.99 64.100699) (xy 115.688998 64.401701) (xy 115.66 64.425499) (xy 115.565026 64.541224) + (xy 115.494454 64.673253) (xy 115.450997 64.816514) (xy 115.44 64.928167) (xy 115.44 64.928178) (xy 115.436324 64.9655) + (xy 115.44 65.002822) (xy 115.44 65.102843) (xy 115.397089 65.20644) (xy 115.365 65.36776) (xy 115.365 65.53224) + (xy 115.397089 65.69356) (xy 115.460033 65.845521) (xy 115.551413 65.982281) (xy 115.667719 66.098587) (xy 115.804479 66.189967) + (xy 115.95644 66.252911) (xy 116.11776 66.285) (xy 116.28224 66.285) (xy 116.44356 66.252911) (xy 116.595521 66.189967) + (xy 116.732281 66.098587) (xy 116.848587 65.982281) (xy 116.939967 65.845521) (xy 117.002911 65.69356) (xy 117.0312 65.551342) + (xy 117.05582 65.564502) (xy 117.175518 65.600812) (xy 117.3 65.613072) (xy 118.04 65.613072) (xy 118.04 65.815123) + (xy 118.036565 65.85) (xy 118.050273 65.989184) (xy 118.090872 66.12302) (xy 118.1568 66.246363) (xy 118.245525 66.354475) + (xy 118.259365 66.365833) (xy 117.488998 67.136201) (xy 117.46 67.159999) (xy 117.436202 67.188997) (xy 117.436201 67.188998) + (xy 117.365026 67.275724) (xy 117.294454 67.407754) (xy 117.270719 67.486002) (xy 117.250998 67.551014) (xy 117.240001 67.662667) + (xy 117.236324 67.7) (xy 117.240001 67.737332) (xy 117.240001 68.282863) (xy 117.153475 68.153368) (xy 116.946632 67.946525) + (xy 116.703411 67.78401) (xy 116.433158 67.672068) (xy 116.14626 67.615) (xy 115.976697 67.615) (xy 115.882327 67.575911) + (xy 115.576109 67.515) (xy 115.263891 67.515) (xy 114.957673 67.575911) (xy 114.669221 67.695391) (xy 114.409621 67.86885) + (xy 114.18885 68.089621) (xy 114.015391 68.349221) (xy 113.895911 68.637673) (xy 113.835 68.943891) (xy 113.835 69.256109) + (xy 113.895911 69.562327) (xy 114.015391 69.850779) (xy 114.143113 70.041928) (xy 112.35 70.041928) (xy 112.225518 70.054188) + (xy 112.10582 70.090498) (xy 111.995506 70.149463) (xy 111.900487 70.227443) (xy 111.658049 69.985005) (xy 111.732235 69.985005) + (xy 111.893555 69.952916) (xy 112.045516 69.889972) (xy 112.182276 69.798592) (xy 112.298582 69.682286) (xy 112.389962 69.545526) + (xy 112.452906 69.393565) (xy 112.484995 69.232245) (xy 112.484995 69.067765) (xy 112.452906 68.906445) (xy 112.409995 68.802848) + (xy 112.409995 64.864806) (xy 112.610998 64.663803) (xy 112.640001 64.640001) (xy 112.734974 64.524276) (xy 112.805546 64.392247) + (xy 112.849003 64.248986) (xy 112.86 64.137333) (xy 112.86 64.137324) (xy 112.863676 64.100001) (xy 112.86 64.062678) + (xy 112.86 60.911578) + ) + ) + (filled_polygon + (pts + (xy 104.427 68.67262) (xy 104.447 68.67262) (xy 104.447 68.844808) (xy 104.153 68.844808) (xy 104.153 68.67262) + (xy 104.173 68.67262) (xy 104.173 68.65262) (xy 104.427 68.65262) + ) + ) + (filled_polygon + (pts + (xy 141.175 49.829721) (xy 141.175 50.250279) (xy 141.244302 50.598682) (xy 141.028698 50.687988) (xy 140.679017 50.921637) + (xy 140.381637 51.219017) (xy 140.147988 51.568698) (xy 139.987047 51.957244) (xy 139.905 52.369721) (xy 139.905 52.790279) + (xy 139.987047 53.202756) (xy 140.147988 53.591302) (xy 140.381637 53.940983) (xy 140.679017 54.238363) (xy 141.028698 54.472012) + (xy 141.417244 54.632953) (xy 141.829721 54.715) (xy 142.250279 54.715) (xy 142.662756 54.632953) (xy 143.051302 54.472012) + (xy 143.400983 54.238363) (xy 143.540001 54.099345) (xy 143.54 54.552843) (xy 143.497089 54.65644) (xy 143.465 54.81776) + (xy 143.465 54.98224) (xy 143.497089 55.14356) (xy 143.560033 55.295521) (xy 143.651413 55.432281) (xy 143.767719 55.548587) + (xy 143.904479 55.639967) (xy 144.008078 55.682879) (xy 145.095001 56.769803) (xy 145.095002 65.097729) (xy 145.042327 65.075911) + (xy 144.736109 65.015) (xy 144.423891 65.015) (xy 144.117673 65.075911) (xy 144.023303 65.115) (xy 143.85374 65.115) + (xy 143.566842 65.172068) (xy 143.296589 65.28401) (xy 143.053368 65.446525) (xy 142.846525 65.653368) (xy 142.68401 65.896589) + (xy 142.572068 66.166842) (xy 142.515 66.45374) (xy 142.515 66.74626) (xy 142.572068 67.033158) (xy 142.607988 67.119876) + (xy 142.298698 67.247988) (xy 142.076252 67.396622) (xy 142.081817 67.383186) (xy 142.185 66.864449) (xy 142.185 66.335551) + (xy 142.081817 65.816814) (xy 141.879417 65.328175) (xy 141.585576 64.888412) (xy 141.211588 64.514424) (xy 140.771825 64.220583) + (xy 140.625564 64.16) (xy 141.215123 64.16) (xy 141.25 64.163435) (xy 141.284877 64.16) (xy 141.312485 64.157281) + (xy 141.389184 64.149727) (xy 141.52302 64.109128) (xy 141.646363 64.0432) (xy 141.754475 63.954475) (xy 141.8432 63.846363) + (xy 141.909128 63.72302) (xy 141.949727 63.589184) (xy 141.96 63.484877) (xy 141.96 63.484876) (xy 141.963435 63.45) + (xy 141.96 63.415123) (xy 141.96 63.11) (xy 142.027002 63.11) (xy 142.027002 62.951252) (xy 142.18575 63.11) + (xy 142.7 63.113072) (xy 142.824482 63.100812) (xy 142.94418 63.064502) (xy 143.054494 63.005537) (xy 143.151185 62.926185) + (xy 143.230537 62.829494) (xy 143.289502 62.71918) (xy 143.325812 62.599482) (xy 143.338072 62.475) (xy 143.335 62.26075) + (xy 143.17625 62.102) (xy 142.027 62.102) (xy 142.027 62.122) (xy 141.96 62.122) (xy 141.96 61.828) + (xy 142.027 61.828) (xy 142.027 61.848) (xy 143.17625 61.848) (xy 143.243985 61.780265) (xy 143.26776 61.784994) + (xy 143.43224 61.784994) (xy 143.59356 61.752905) (xy 143.745521 61.689961) (xy 143.882281 61.598581) (xy 143.998587 61.482275) + (xy 144.089967 61.345515) (xy 144.152911 61.193554) (xy 144.185 61.032234) (xy 144.185 60.867754) (xy 144.152911 60.706434) + (xy 144.11 60.602837) (xy 144.11 60.519822) (xy 144.113676 60.482499) (xy 144.11 60.445176) (xy 144.11 60.445167) + (xy 144.099003 60.333514) (xy 144.055546 60.190253) (xy 143.984974 60.058224) (xy 143.890001 59.942499) (xy 143.860998 59.918697) + (xy 143.556304 59.614003) (xy 143.532501 59.584999) (xy 143.416776 59.490026) (xy 143.284747 59.419454) (xy 143.251273 59.4093) + (xy 143.230537 59.370506) (xy 143.151185 59.273815) (xy 143.054494 59.194463) (xy 142.94418 59.135498) (xy 142.824482 59.099188) + (xy 142.7 59.086928) (xy 142.66 59.086928) (xy 142.66 58.237323) (xy 142.663676 58.2) (xy 142.66 58.162677) + (xy 142.66 58.162667) (xy 142.649003 58.051014) (xy 142.605546 57.907753) (xy 142.534974 57.775724) (xy 142.440001 57.659999) + (xy 142.411004 57.636202) (xy 139.545001 54.7702) (xy 139.545001 50.237326) (xy 139.548677 50.200003) (xy 139.547199 50.185) + (xy 139.764449 50.185) (xy 140.283186 50.081817) (xy 140.771825 49.879417) (xy 141.211588 49.585576) (xy 141.226537 49.570627) + ) + ) + (filled_polygon + (pts + (xy 199.227 66.548) (xy 199.247 66.548) (xy 199.247 66.802) (xy 199.227 66.802) (xy 199.227 66.822) + (xy 199.16 66.822) (xy 199.16 66.528) (xy 199.227 66.528) + ) + ) + (filled_polygon + (pts + (xy 218.227 66.548) (xy 218.247 66.548) (xy 218.247 66.802) (xy 218.227 66.802) (xy 218.227 66.822) + (xy 218.16 66.822) (xy 218.16 66.528) (xy 218.227 66.528) + ) + ) + (filled_polygon + (pts + (xy 186.886928 48.436731) (xy 186.886928 49.125) (xy 186.899188 49.249482) (xy 186.935498 49.36918) (xy 186.994463 49.479494) + (xy 187.073815 49.576185) (xy 187.167863 49.653368) (xy 187.165 49.66776) (xy 187.165 49.83224) (xy 187.197089 49.99356) + (xy 187.260033 50.145521) (xy 187.329844 50.25) (xy 187.260033 50.354479) (xy 187.197089 50.50644) (xy 187.165 50.66776) + (xy 187.165 50.83224) (xy 187.167863 50.846632) (xy 187.073815 50.923815) (xy 186.994463 51.020506) (xy 186.935498 51.13082) + (xy 186.899188 51.250518) (xy 186.886928 51.375) (xy 186.886928 52.675) (xy 186.899188 52.799482) (xy 186.935498 52.91918) + (xy 186.994463 53.029494) (xy 187.073815 53.126185) (xy 187.170506 53.205537) (xy 187.28082 53.264502) (xy 187.400518 53.300812) + (xy 187.525 53.313072) (xy 188.475 53.313072) (xy 188.599482 53.300812) (xy 188.71918 53.264502) (xy 188.829494 53.205537) + (xy 188.926185 53.126185) (xy 188.940001 53.109351) (xy 188.940001 53.341928) (xy 188.55 53.341928) (xy 188.425518 53.354188) + (xy 188.30582 53.390498) (xy 188.195506 53.449463) (xy 188.098815 53.528815) (xy 188.019463 53.625506) (xy 187.960498 53.73582) + (xy 187.924188 53.855518) (xy 187.911928 53.98) (xy 187.911928 55.98) (xy 187.924188 56.104482) (xy 187.960498 56.22418) + (xy 188.019463 56.334494) (xy 188.098815 56.431185) (xy 188.195506 56.510537) (xy 188.30582 56.569502) (xy 188.37143 56.589405) + (xy 188.457754 56.635546) (xy 188.601015 56.679002) (xy 188.659381 56.684751) (xy 188.626413 56.717719) (xy 188.535033 56.854479) + (xy 188.472089 57.00644) (xy 188.44 57.16776) (xy 188.44 57.33224) (xy 188.472089 57.49356) (xy 188.515001 57.597158) + (xy 188.515 58.275179) (xy 188.511324 58.312502) (xy 188.515 58.349824) (xy 188.515 58.349834) (xy 188.525997 58.461487) + (xy 188.565288 58.591014) (xy 188.569454 58.604748) (xy 188.640026 58.736778) (xy 188.670562 58.773986) (xy 188.734999 58.852503) + (xy 188.764002 58.876305) (xy 189.439998 59.552302) (xy 189.439999 62.819167) (xy 189.419052 62.815) (xy 189.254572 62.815) + (xy 189.093252 62.847089) (xy 188.989655 62.89) (xy 181.173426 62.89) (xy 181.251185 62.826185) (xy 181.330537 62.729494) + (xy 181.389502 62.61918) (xy 181.425812 62.499482) (xy 181.438072 62.375) (xy 181.435 62.16075) (xy 181.276252 62.002002) + (xy 181.435 62.002002) (xy 181.435 61.928484) (xy 181.467758 61.935) (xy 181.632238 61.935) (xy 181.793558 61.902911) + (xy 181.945519 61.839967) (xy 182.082279 61.748587) (xy 182.198585 61.632281) (xy 182.239423 61.571163) (xy 182.301424 61.663954) + (xy 182.41773 61.78026) (xy 182.55449 61.87164) (xy 182.706451 61.934584) (xy 182.867771 61.966673) (xy 183.032251 61.966673) + (xy 183.193571 61.934584) (xy 183.345532 61.87164) (xy 183.482292 61.78026) (xy 183.598598 61.663954) (xy 183.689978 61.527194) + (xy 183.752922 61.375233) (xy 183.785011 61.213913) (xy 183.785011 61.049433) (xy 183.752922 60.888113) (xy 183.710011 60.784516) + (xy 183.710011 55.437333) (xy 183.713687 55.40001) (xy 183.710011 55.362688) (xy 183.710011 55.362678) (xy 183.699014 55.251025) + (xy 183.655557 55.107764) (xy 183.636975 55.073) (xy 183.584985 54.975734) (xy 183.51381 54.889008) (xy 183.490012 54.86001) + (xy 183.461014 54.836213) (xy 183.182879 54.558077) (xy 183.16 54.502843) (xy 183.16 54.258072) (xy 184.45 54.258072) + (xy 184.574482 54.245812) (xy 184.69418 54.209502) (xy 184.804494 54.150537) (xy 184.901185 54.071185) (xy 184.980537 53.974494) + (xy 185.039502 53.86418) (xy 185.075812 53.744482) (xy 185.088072 53.62) (xy 185.088072 51.62) (xy 185.075812 51.495518) + (xy 185.039502 51.37582) (xy 184.980537 51.265506) (xy 184.901185 51.168815) (xy 184.804494 51.089463) (xy 184.69418 51.030498) + (xy 184.574482 50.994188) (xy 184.45 50.981928) (xy 183.330748 50.981928) (xy 183.462953 50.662756) (xy 183.545 50.250279) + (xy 183.545 49.829721) (xy 183.462953 49.417244) (xy 183.302012 49.028698) (xy 183.264985 48.973283) (xy 183.430779 48.904609) + (xy 183.690379 48.73115) (xy 183.91115 48.510379) (xy 184.084609 48.250779) (xy 184.204089 47.962327) (xy 184.265 47.656109) + (xy 184.265 47.343891) (xy 184.204089 47.037673) (xy 184.084609 46.749221) (xy 183.91115 46.489621) (xy 183.690379 46.26885) + (xy 183.430779 46.095391) (xy 183.142327 45.975911) (xy 182.836109 45.915) (xy 182.523891 45.915) (xy 182.217673 45.975911) + (xy 182.123303 46.015) (xy 181.95374 46.015) (xy 181.666842 46.072068) (xy 181.396589 46.18401) (xy 181.153368 46.346525) + (xy 180.946525 46.553368) (xy 180.78401 46.796589) (xy 180.672068 47.066842) (xy 180.615 47.35374) (xy 180.615 47.64626) + (xy 180.672068 47.933158) (xy 180.707988 48.019876) (xy 180.398698 48.147988) (xy 180.176252 48.296622) (xy 180.181817 48.283186) + (xy 180.285 47.764449) (xy 180.285 47.235551) (xy 180.181817 46.716814) (xy 179.979417 46.228175) (xy 179.750114 45.884999) + (xy 184.335198 45.884999) + ) + ) + (filled_polygon + (pts + (xy 180.127 61.748) (xy 180.147 61.748) (xy 180.147 62.002) (xy 180.127 62.002) (xy 180.127 62.022) + (xy 180.06 62.022) (xy 180.06 61.728) (xy 180.127 61.728) + ) + ) + (filled_polygon + (pts + (xy 181.64 54.502843) (xy 181.597089 54.60644) (xy 181.565 54.76776) (xy 181.565 54.93224) (xy 181.597089 55.09356) + (xy 181.660033 55.245521) (xy 181.751413 55.382281) (xy 181.867719 55.498587) (xy 182.004479 55.589967) (xy 182.108077 55.632879) + (xy 182.190011 55.714813) (xy 182.190012 60.559146) (xy 182.082279 60.451413) (xy 181.945519 60.360033) (xy 181.793558 60.297089) + (xy 181.632238 60.265) (xy 181.481802 60.265) (xy 181.438072 60.22127) (xy 181.438072 59.625) (xy 181.425812 59.500518) + (xy 181.389502 59.38082) (xy 181.330537 59.270506) (xy 181.251185 59.173815) (xy 181.154494 59.094463) (xy 181.04418 59.035498) + (xy 180.924482 58.999188) (xy 180.8 58.986928) (xy 180.76 58.986928) (xy 180.76 58.037322) (xy 180.763676 57.999999) + (xy 180.76 57.962676) (xy 180.76 57.962667) (xy 180.749003 57.851014) (xy 180.705546 57.707753) (xy 180.634974 57.575724) + (xy 180.540001 57.459999) (xy 180.511004 57.436202) (xy 179.074999 56.000198) (xy 179.074999 54.436132) (xy 179.128698 54.472012) + (xy 179.517244 54.632953) (xy 179.929721 54.715) (xy 180.350279 54.715) (xy 180.762756 54.632953) (xy 181.151302 54.472012) + (xy 181.500983 54.238363) (xy 181.640001 54.099345) + ) + ) + (filled_polygon + (pts + (xy 168.136928 44.3) (xy 168.149188 44.424482) (xy 168.185498 44.54418) (xy 168.244463 44.654494) (xy 168.323815 44.751185) + (xy 168.420506 44.830537) (xy 168.468011 44.855929) (xy 168.447089 44.90644) (xy 168.415 45.06776) (xy 168.415 45.23224) + (xy 168.447089 45.39356) (xy 168.510033 45.545521) (xy 168.579844 45.65) (xy 168.510033 45.754479) (xy 168.447089 45.90644) + (xy 168.425095 46.01701) (xy 168.420506 46.019463) (xy 168.323815 46.098815) (xy 168.244463 46.195506) (xy 168.185498 46.30582) + (xy 168.149188 46.425518) (xy 168.136928 46.55) (xy 168.136928 47.85) (xy 168.149188 47.974482) (xy 168.185498 48.09418) + (xy 168.244463 48.204494) (xy 168.323815 48.301185) (xy 168.420506 48.380537) (xy 168.490001 48.417683) (xy 168.490001 48.692668) + (xy 168.486324 48.73) (xy 168.490001 48.767333) (xy 168.500998 48.878986) (xy 168.510281 48.909587) (xy 168.544454 49.022246) + (xy 168.615026 49.154276) (xy 168.672376 49.224156) (xy 168.71 49.270001) (xy 168.738998 49.293799) (xy 168.811928 49.366729) + (xy 168.811928 51.08) (xy 168.824188 51.204482) (xy 168.860498 51.32418) (xy 168.919463 51.434494) (xy 168.998815 51.531185) + (xy 169.095506 51.610537) (xy 169.0962 51.610908) (xy 169.065 51.76776) (xy 169.065 51.93224) (xy 169.097089 52.09356) + (xy 169.160033 52.245521) (xy 169.251413 52.382281) (xy 169.367719 52.498587) (xy 169.504479 52.589967) (xy 169.65644 52.652911) + (xy 169.81776 52.685) (xy 169.98224 52.685) (xy 170.14356 52.652911) (xy 170.295521 52.589967) (xy 170.432281 52.498587) + (xy 170.548587 52.382281) (xy 170.639967 52.245521) (xy 170.702911 52.09356) (xy 170.735 51.93224) (xy 170.735 51.76776) + (xy 170.725116 51.718072) (xy 171.75 51.718072) (xy 171.874482 51.705812) (xy 171.99418 51.669502) (xy 172.104494 51.610537) + (xy 172.201185 51.531185) (xy 172.228525 51.497872) (xy 172.429017 51.698364) (xy 172.778698 51.932013) (xy 172.994302 52.021319) + (xy 172.925 52.369721) (xy 172.925 52.790279) (xy 173.007047 53.202756) (xy 173.167988 53.591302) (xy 173.401637 53.940983) + (xy 173.699017 54.238363) (xy 174.048698 54.472012) (xy 174.437244 54.632953) (xy 174.849721 54.715) (xy 175.270279 54.715) + (xy 175.682756 54.632953) (xy 176.071302 54.472012) (xy 176.420983 54.238363) (xy 176.718363 53.940983) (xy 176.952012 53.591302) + (xy 177.112953 53.202756) (xy 177.195 52.790279) (xy 177.195 52.369721) (xy 177.112953 51.957244) (xy 176.957043 51.580845) + (xy 177.554999 52.178801) (xy 177.555 56.277667) (xy 177.551323 56.314999) (xy 177.555 56.352332) (xy 177.565997 56.463985) + (xy 177.574085 56.490647) (xy 177.609453 56.607245) (xy 177.680025 56.739275) (xy 177.741724 56.814454) (xy 177.774999 56.855) + (xy 177.803997 56.878798) (xy 178.963598 58.0384) (xy 175.884877 58.0384) (xy 175.85 58.034965) (xy 175.815123 58.0384) + (xy 175.710816 58.048673) (xy 175.57698 58.089272) (xy 175.453637 58.1552) (xy 175.345525 58.243925) (xy 175.2568 58.352037) + (xy 175.190872 58.47538) (xy 175.150273 58.609216) (xy 175.136565 58.7484) (xy 175.140001 58.783287) (xy 175.140001 58.986928) + (xy 174.4 58.986928) (xy 174.275518 58.999188) (xy 174.15582 59.035498) (xy 174.045506 59.094463) (xy 173.948815 59.173815) + (xy 173.894499 59.24) (xy 173.418466 59.24) (xy 173.374999 59.235719) (xy 173.331533 59.24) (xy 173.331523 59.24) + (xy 173.20151 59.252805) (xy 173.034687 59.303411) (xy 172.880941 59.385589) (xy 172.746183 59.496183) (xy 172.718466 59.529956) + (xy 172.404956 59.843466) (xy 172.371183 59.871183) (xy 172.260589 60.005942) (xy 172.178411 60.159688) (xy 172.14541 60.268476) + (xy 172.141845 60.280229) (xy 170.812218 58.950603) (xy 170.788415 58.921599) (xy 170.67269 58.826626) (xy 170.540661 58.756054) + (xy 170.3974 58.712597) (xy 170.285747 58.7016) (xy 170.285736 58.7016) (xy 170.248414 58.697924) (xy 170.211092 58.7016) + (xy 168.736408 58.7016) (xy 166.532882 56.498075) (xy 166.48997 56.394476) (xy 166.39859 56.257716) (xy 166.282284 56.14141) + (xy 166.145524 56.05003) (xy 165.993563 55.987086) (xy 165.832243 55.954997) (xy 165.667763 55.954997) (xy 165.657828 55.956973) + (xy 166.286004 55.328798) (xy 166.315002 55.305) (xy 166.341882 55.272247) (xy 166.409975 55.189276) (xy 166.480547 55.057246) + (xy 166.487295 55.035) (xy 166.524004 54.913985) (xy 166.535001 54.802332) (xy 166.535001 54.802323) (xy 166.538677 54.765) + (xy 166.535001 54.727677) (xy 166.535001 51.632323) (xy 166.538677 51.595) (xy 166.535001 51.557677) (xy 166.535001 51.557668) + (xy 166.524004 51.446015) (xy 166.480547 51.302754) (xy 166.409975 51.170725) (xy 166.377226 51.13082) (xy 166.3388 51.083997) + (xy 166.338796 51.083993) (xy 166.315002 51.055) (xy 166.28601 51.031207) (xy 166.088072 50.833269) (xy 166.088072 49.12) + (xy 166.075812 48.995518) (xy 166.039502 48.87582) (xy 165.980537 48.765506) (xy 165.901185 48.668815) (xy 165.804494 48.589463) + (xy 165.69418 48.530498) (xy 165.574482 48.494188) (xy 165.45 48.481928) (xy 164.330748 48.481928) (xy 164.462953 48.162756) + (xy 164.545 47.750279) (xy 164.545 47.329721) (xy 164.462953 46.917244) (xy 164.302012 46.528698) (xy 164.264985 46.473283) + (xy 164.430779 46.404609) (xy 164.690379 46.23115) (xy 164.91115 46.010379) (xy 165.084609 45.750779) (xy 165.204089 45.462327) + (xy 165.265 45.156109) (xy 165.265 44.843891) (xy 165.204089 44.537673) (xy 165.10382 44.2956) (xy 168.136928 44.2956) + ) + ) + (filled_polygon + (pts + (xy 162.790001 59.825197) (xy 162.370536 60.244662) (xy 162.389502 60.20918) (xy 162.425812 60.089482) (xy 162.438072 59.965) + (xy 162.435 59.75075) (xy 162.276252 59.592002) (xy 162.435 59.592002) (xy 162.435 59.564505) (xy 162.54356 59.542911) + (xy 162.647157 59.5) (xy 162.79 59.5) + ) + ) + (filled_polygon + (pts + (xy 161.127 59.338) (xy 161.147 59.338) (xy 161.147 59.592) (xy 161.127 59.592) (xy 161.127 59.612) + (xy 161.06 59.612) (xy 161.06 59.318) (xy 161.127 59.318) + ) + ) + (filled_polygon + (pts + (xy 149.386928 45.465) (xy 149.399188 45.589482) (xy 149.435498 45.70918) (xy 149.494463 45.819494) (xy 149.573815 45.916185) + (xy 149.670506 45.995537) (xy 149.78082 46.054502) (xy 149.900518 46.090812) (xy 150.025 46.103072) (xy 150.030183 46.103072) + (xy 149.998815 46.128815) (xy 149.919463 46.225506) (xy 149.860498 46.33582) (xy 149.824188 46.455518) (xy 149.811928 46.58) + (xy 149.811928 48.384982) (xy 149.800998 48.421014) (xy 149.793218 48.500001) (xy 149.786324 48.57) (xy 149.790001 48.607332) + (xy 149.79 49.292842) (xy 149.747089 49.39644) (xy 149.715 49.55776) (xy 149.715 49.72224) (xy 149.747089 49.88356) + (xy 149.79 49.987157) (xy 149.790001 51.568116) (xy 149.717719 51.616413) (xy 149.601413 51.732719) (xy 149.510033 51.869479) + (xy 149.447089 52.02144) (xy 149.415 52.18276) (xy 149.415 52.34724) (xy 149.447089 52.50856) (xy 149.510033 52.660521) + (xy 149.601413 52.797281) (xy 149.717719 52.913587) (xy 149.854479 53.004967) (xy 149.958078 53.047879) (xy 152.140001 55.229803) + (xy 152.14 55.675199) (xy 151.739003 56.076196) (xy 151.709999 56.099999) (xy 151.664042 56.155998) (xy 151.615026 56.215724) + (xy 151.55799 56.322431) (xy 151.544454 56.347754) (xy 151.500997 56.491015) (xy 151.49 56.602668) (xy 151.49 56.602678) + (xy 151.486324 56.64) (xy 151.49 56.677323) (xy 151.49 58.568605) (xy 151.398986 58.540997) (xy 151.352874 58.536455) + (xy 151.350812 58.515518) (xy 151.314502 58.39582) (xy 151.255537 58.285506) (xy 151.176185 58.188815) (xy 151.079494 58.109463) + (xy 150.96918 58.050498) (xy 150.849482 58.014188) (xy 150.725 58.001928) (xy 149.775 58.001928) (xy 149.650518 58.014188) + (xy 149.53082 58.050498) (xy 149.420506 58.109463) (xy 149.323815 58.188815) (xy 149.244463 58.285506) (xy 149.185498 58.39582) + (xy 149.149188 58.515518) (xy 149.147762 58.53) (xy 148.036722 58.53) (xy 147.999399 58.526324) (xy 147.962076 58.53) + (xy 147.962067 58.53) (xy 147.850414 58.540997) (xy 147.720801 58.580314) (xy 147.707153 58.584454) (xy 147.575123 58.655026) + (xy 147.510867 58.70776) (xy 147.459399 58.749999) (xy 147.435601 58.778997) (xy 146.615001 59.599598) (xy 146.615001 58.128483) + (xy 146.74356 58.102911) (xy 146.847157 58.06) (xy 147.852678 58.06) (xy 147.89 58.063676) (xy 147.927322 58.06) + (xy 147.927333 58.06) (xy 148.038986 58.049003) (xy 148.182247 58.005546) (xy 148.314276 57.934974) (xy 148.430001 57.840001) + (xy 148.453803 57.810998) (xy 149.541925 56.722878) (xy 149.645521 56.679967) (xy 149.782281 56.588587) (xy 149.898587 56.472281) + (xy 149.989967 56.335521) (xy 150.052911 56.18356) (xy 150.085 56.02224) (xy 150.085 55.85776) (xy 150.052911 55.69644) + (xy 149.989967 55.544479) (xy 149.898587 55.407719) (xy 149.782281 55.291413) (xy 149.645521 55.200033) (xy 149.49356 55.137089) + (xy 149.33224 55.105) (xy 149.16776 55.105) (xy 149.00644 55.137089) (xy 148.854479 55.200033) (xy 148.717719 55.291413) + (xy 148.601413 55.407719) (xy 148.510033 55.544479) (xy 148.467122 55.648075) (xy 147.575199 56.54) (xy 146.847157 56.54) + (xy 146.74356 56.497089) (xy 146.617012 56.471917) (xy 146.618678 56.455001) (xy 146.604004 56.306015) (xy 146.560547 56.162754) + (xy 146.489975 56.030725) (xy 146.421891 55.947764) (xy 146.395002 55.915) (xy 146.366005 55.891203) (xy 145.082879 54.608078) + (xy 145.06 54.552843) (xy 145.06 54.258072) (xy 146.35 54.258072) (xy 146.474482 54.245812) (xy 146.59418 54.209502) + (xy 146.704494 54.150537) (xy 146.801185 54.071185) (xy 146.880537 53.974494) (xy 146.939502 53.86418) (xy 146.975812 53.744482) + (xy 146.988072 53.62) (xy 146.988072 51.62) (xy 146.975812 51.495518) (xy 146.939502 51.37582) (xy 146.880537 51.265506) + (xy 146.801185 51.168815) (xy 146.704494 51.089463) (xy 146.59418 51.030498) (xy 146.474482 50.994188) (xy 146.35 50.981928) + (xy 145.230748 50.981928) (xy 145.362953 50.662756) (xy 145.445 50.250279) (xy 145.445 49.829721) (xy 145.362953 49.417244) + (xy 145.202012 49.028698) (xy 145.164985 48.973283) (xy 145.330779 48.904609) (xy 145.590379 48.73115) (xy 145.81115 48.510379) + (xy 145.984609 48.250779) (xy 146.104089 47.962327) (xy 146.165 47.656109) (xy 146.165 47.343891) (xy 146.104089 47.037673) + (xy 145.984609 46.749221) (xy 145.81115 46.489621) (xy 145.590379 46.26885) (xy 145.330779 46.095391) (xy 145.042327 45.975911) + (xy 144.736109 45.915) (xy 144.423891 45.915) (xy 144.117673 45.975911) (xy 144.023303 46.015) (xy 143.85374 46.015) + (xy 143.566842 46.072068) (xy 143.296589 46.18401) (xy 143.053368 46.346525) (xy 142.846525 46.553368) (xy 142.68401 46.796589) + (xy 142.572068 47.066842) (xy 142.515 47.35374) (xy 142.515 47.64626) (xy 142.572068 47.933158) (xy 142.607988 48.019876) + (xy 142.298698 48.147988) (xy 142.076252 48.296622) (xy 142.081817 48.283186) (xy 142.185 47.764449) (xy 142.185 47.235551) + (xy 142.081817 46.716814) (xy 141.879417 46.228175) (xy 141.585576 45.788412) (xy 141.557172 45.760008) (xy 147.68517 45.760008) + (xy 147.722492 45.763684) (xy 147.759814 45.760008) (xy 147.759825 45.760008) (xy 147.871478 45.749011) (xy 148.014739 45.705554) + (xy 148.146768 45.634982) (xy 148.262493 45.540009) (xy 148.286296 45.511005) (xy 149.386928 44.410373) + ) + ) + (filled_polygon + (pts + (xy 116.661928 45.31173) (xy 116.661928 45.875) (xy 116.674188 45.999482) (xy 116.710498 46.11918) (xy 116.769463 46.229494) + (xy 116.848815 46.326185) (xy 116.945506 46.405537) (xy 117.05582 46.464502) (xy 117.175518 46.500812) (xy 117.3 46.513072) + (xy 118.04 46.513072) (xy 118.04 46.715123) (xy 118.036565 46.75) (xy 118.050273 46.889184) (xy 118.090872 47.02302) + (xy 118.099948 47.04) (xy 114.960323 47.04) (xy 114.922998 47.036324) (xy 114.885673 47.04) (xy 114.885665 47.04) + (xy 114.774012 47.050997) (xy 114.630751 47.094454) (xy 114.498722 47.165026) (xy 114.382997 47.259999) (xy 114.359199 47.288997) + (xy 111.388998 50.259199) (xy 111.36 50.282997) (xy 111.336202 50.311995) (xy 111.336201 50.311996) (xy 111.265026 50.398722) + (xy 111.194454 50.530752) (xy 111.175554 50.59306) (xy 111.150998 50.674012) (xy 111.144236 50.742667) (xy 111.136324 50.822998) + (xy 111.140001 50.86033) (xy 111.14 58.448386) (xy 110.142642 59.445745) (xy 109.891156 59.445745) (xy 109.803935 59.31521) + (xy 109.60935 59.120625) (xy 109.380542 58.96774) (xy 109.3033 58.935745) (xy 109.380542 58.90375) (xy 109.60935 58.750865) + (xy 109.803935 58.55628) (xy 109.95682 58.327472) (xy 110.062129 58.073235) (xy 110.115815 57.803337) (xy 110.115815 57.528153) + (xy 110.062129 57.258255) (xy 109.95682 57.004018) (xy 109.803935 56.77521) (xy 109.60935 56.580625) (xy 109.380542 56.42774) + (xy 109.3033 56.395745) (xy 109.380542 56.36375) (xy 109.60935 56.210865) (xy 109.803935 56.01628) (xy 109.95682 55.787472) + (xy 110.062129 55.533235) (xy 110.115815 55.263337) (xy 110.115815 54.988153) (xy 110.062129 54.718255) (xy 109.95682 54.464018) + (xy 109.803935 54.23521) (xy 109.60935 54.040625) (xy 109.380542 53.88774) (xy 109.3033 53.855745) (xy 109.380542 53.82375) + (xy 109.60935 53.670865) (xy 109.803935 53.47628) (xy 109.95682 53.247472) (xy 110.062129 52.993235) (xy 110.115815 52.723337) + (xy 110.115815 52.448153) (xy 110.062129 52.178255) (xy 109.95682 51.924018) (xy 109.803935 51.69521) (xy 109.60935 51.500625) + (xy 109.380542 51.34774) (xy 109.308872 51.318053) (xy 109.321838 51.313381) (xy 109.437795 51.251401) (xy 109.504775 51.01131) + (xy 108.718815 50.22535) (xy 108.704673 50.239493) (xy 108.525068 50.059888) (xy 108.53921 50.045745) (xy 108.89842 50.045745) + (xy 109.68438 50.831705) (xy 109.924471 50.764725) (xy 110.041571 50.515697) (xy 110.107838 50.24861) (xy 110.120725 49.973728) + (xy 110.079737 49.701612) (xy 109.986451 49.442722) (xy 109.924471 49.326765) (xy 109.68438 49.259785) (xy 108.89842 50.045745) + (xy 108.53921 50.045745) (xy 108.525068 50.031603) (xy 108.704673 49.851998) (xy 108.718815 49.86614) (xy 109.504775 49.08018) + (xy 109.437795 48.840089) (xy 109.307171 48.778666) (xy 109.321838 48.773381) (xy 109.437795 48.711401) (xy 109.502599 48.479109) + (xy 109.51059 48.494059) (xy 109.621183 48.628817) (xy 109.755941 48.73941) (xy 109.909687 48.821588) (xy 110.07651 48.872195) + (xy 110.25 48.889281) (xy 110.42349 48.872195) (xy 110.590313 48.821588) (xy 110.744059 48.73941) (xy 110.845046 48.656532) + (xy 112.381532 47.120047) (xy 112.381536 47.120042) (xy 114.116579 45.385) (xy 115.956531 45.385) (xy 116 45.389281) + (xy 116.043469 45.385) (xy 116.043477 45.385) (xy 116.17349 45.372195) (xy 116.340313 45.321589) (xy 116.494059 45.239411) + (xy 116.54654 45.196341) + ) + ) + (filled_polygon + (pts + (xy 160.344302 48.098682) (xy 160.128698 48.187988) (xy 159.779017 48.421637) (xy 159.481637 48.719017) (xy 159.247988 49.068698) + (xy 159.087047 49.457244) (xy 159.005 49.869721) (xy 159.005 50.290279) (xy 159.087047 50.702756) (xy 159.247988 51.091302) + (xy 159.481637 51.440983) (xy 159.779017 51.738363) (xy 159.836734 51.776928) (xy 159.7 51.776928) (xy 159.575518 51.789188) + (xy 159.45582 51.825498) (xy 159.345506 51.884463) (xy 159.248815 51.963815) (xy 159.169463 52.060506) (xy 159.110498 52.17082) + (xy 159.074188 52.290518) (xy 159.061928 52.415) (xy 159.061928 52.955) (xy 158.91776 52.955) (xy 158.75644 52.987089) + (xy 158.604479 53.050033) (xy 158.467719 53.141413) (xy 158.351413 53.257719) (xy 158.260033 53.394479) (xy 158.197089 53.54644) + (xy 158.165 53.70776) (xy 158.165 53.87224) (xy 158.197089 54.03356) (xy 158.24 54.137157) (xy 158.24 54.187678) + (xy 158.236324 54.225) (xy 158.24 54.262322) (xy 158.24 54.262333) (xy 158.250997 54.373986) (xy 158.294454 54.517247) + (xy 158.365026 54.649276) (xy 158.431275 54.73) (xy 156.153 54.73) (xy 156.153 54.538) (xy 156.173 54.538) + (xy 156.173 54.518) (xy 156.427 54.518) (xy 156.427 54.538) (xy 157.77625 54.538) (xy 157.935 54.37925) + (xy 157.938072 54.165) (xy 157.925812 54.040518) (xy 157.889502 53.92082) (xy 157.830537 53.810506) (xy 157.813708 53.79) + (xy 157.830537 53.769494) (xy 157.889502 53.65918) (xy 157.925812 53.539482) (xy 157.938072 53.415) (xy 157.938072 52.415) + (xy 157.925812 52.290518) (xy 157.889502 52.17082) (xy 157.830537 52.060506) (xy 157.751185 51.963815) (xy 157.654494 51.884463) + (xy 157.54418 51.825498) (xy 157.424482 51.789188) (xy 157.355139 51.782359) (xy 157.420983 51.738363) (xy 157.718363 51.440983) + (xy 157.952012 51.091302) (xy 158.112953 50.702756) (xy 158.195 50.290279) (xy 158.195 49.869721) (xy 158.112953 49.457244) + (xy 157.952012 49.068698) (xy 157.718363 48.719017) (xy 157.420983 48.421637) (xy 157.071302 48.187988) (xy 156.855698 48.098682) + (xy 156.897651 47.887772) (xy 156.919998 47.915002) (xy 156.948991 47.938796) (xy 156.948995 47.9388) (xy 156.999862 47.980545) + (xy 157.035723 48.009975) (xy 157.167752 48.080547) (xy 157.311013 48.124004) (xy 157.422666 48.135001) (xy 157.422675 48.135001) + (xy 157.459998 48.138677) (xy 157.497321 48.135001) (xy 159.702679 48.135001) (xy 159.740001 48.138677) (xy 159.777323 48.135001) + (xy 159.777334 48.135001) (xy 159.888987 48.124004) (xy 160.032248 48.080547) (xy 160.164277 48.009975) (xy 160.280002 47.915002) + (xy 160.302349 47.887772) + ) + ) + (filled_polygon + (pts + (xy 153.429017 49.198364) (xy 153.778698 49.432013) (xy 153.994302 49.521319) (xy 153.925 49.869721) (xy 153.925 50.290279) + (xy 154.007047 50.702756) (xy 154.167988 51.091302) (xy 154.401637 51.440983) (xy 154.699017 51.738363) (xy 154.933014 51.894715) + (xy 154.848815 51.963815) (xy 154.769463 52.060506) (xy 154.710498 52.17082) (xy 154.69949 52.207107) (xy 154.691753 52.209454) + (xy 154.559724 52.280026) (xy 154.443999 52.374999) (xy 154.420199 52.404) (xy 153.989003 52.835196) (xy 153.959999 52.858999) + (xy 153.9163 52.912247) (xy 153.865026 52.974724) (xy 153.825865 53.047989) (xy 153.794454 53.106754) (xy 153.750997 53.250015) + (xy 153.74 53.361668) (xy 153.74 53.361678) (xy 153.736324 53.399) (xy 153.74 53.436322) (xy 153.74 53.442843) + (xy 153.697089 53.54644) (xy 153.673689 53.664076) (xy 151.31 51.300387) (xy 151.31 49.987157) (xy 151.352911 49.88356) + (xy 151.385 49.72224) (xy 151.385 49.55776) (xy 151.352911 49.39644) (xy 151.31 49.292843) (xy 151.31 49.218072) + (xy 152.75 49.218072) (xy 152.874482 49.205812) (xy 152.99418 49.169502) (xy 153.104494 49.110537) (xy 153.201185 49.031185) + (xy 153.228525 48.997872) + ) + ) + (filled_polygon + (pts + (xy 192.35597 45.332549) (xy 192.383683 45.366317) (xy 192.417451 45.39403) (xy 192.417453 45.394032) (xy 192.467373 45.435) + (xy 192.518441 45.476911) (xy 192.672187 45.559089) (xy 192.83901 45.609695) (xy 192.861928 45.611952) (xy 192.861928 45.915) + (xy 192.71776 45.915) (xy 192.55644 45.947089) (xy 192.404479 46.010033) (xy 192.267719 46.101413) (xy 192.151413 46.217719) + (xy 192.060033 46.354479) (xy 191.997089 46.50644) (xy 191.993706 46.523449) (xy 191.965764 46.575724) (xy 191.953454 46.598754) + (xy 191.909997 46.742015) (xy 191.899 46.853668) (xy 191.899 46.853678) (xy 191.895324 46.891) (xy 191.899 46.928323) + (xy 191.899001 47.871668) (xy 191.895324 47.909) (xy 191.899001 47.946333) (xy 191.909998 48.057986) (xy 191.920391 48.092247) + (xy 191.953454 48.201246) (xy 192.024026 48.333276) (xy 192.086971 48.409974) (xy 192.119 48.449001) (xy 192.147998 48.472799) + (xy 192.915198 49.24) (xy 189.101746 49.24) (xy 189.113072 49.125) (xy 189.113072 47.825) (xy 189.100812 47.700518) + (xy 189.064502 47.58082) (xy 189.005537 47.470506) (xy 188.926185 47.373815) (xy 188.829494 47.294463) (xy 188.71918 47.235498) + (xy 188.599482 47.199188) (xy 188.475 47.186928) (xy 188.4749 47.186928) (xy 188.532281 47.148587) (xy 188.648587 47.032281) + (xy 188.739967 46.895521) (xy 188.802911 46.74356) (xy 188.835 46.58224) (xy 188.835 46.41776) (xy 188.802911 46.25644) + (xy 188.739967 46.104479) (xy 188.648587 45.967719) (xy 188.532281 45.851413) (xy 188.395521 45.760033) (xy 188.291924 45.717122) + (xy 182.7098 40.134999) (xy 187.158421 40.134999) + ) + ) + (filled_polygon + (pts + (xy 106.181995 46.971727) (xy 106.33488 47.200535) (xy 106.529465 47.39512) (xy 106.758273 47.548005) (xy 106.835515 47.58) + (xy 106.758273 47.611995) (xy 106.529465 47.76488) (xy 106.33488 47.959465) (xy 106.181995 48.188273) (xy 106.076686 48.44251) + (xy 106.023 48.712408) (xy 106.023 48.987592) (xy 106.024299 48.994123) (xy 105.857677 49.160745) (xy 94.567633 49.160745) + (xy 94.563935 49.15521) (xy 94.36935 48.960625) (xy 94.140542 48.80774) (xy 94.0633 48.775745) (xy 94.140542 48.74375) + (xy 94.36935 48.590865) (xy 94.563935 48.39628) (xy 94.651156 48.265745) (xy 104.356933 48.265745) (xy 104.394255 48.269421) + (xy 104.431577 48.265745) (xy 104.431588 48.265745) (xy 104.543241 48.254748) (xy 104.686502 48.211291) (xy 104.818531 48.140719) + (xy 104.934256 48.045746) (xy 104.958059 48.016742) (xy 106.014802 46.96) (xy 106.177137 46.96) + ) + ) + (filled_polygon + (pts + (xy 205.499941 45.113211) (xy 205.653687 45.195389) (xy 205.82051 45.245995) (xy 205.950523 45.2588) (xy 205.950533 45.2588) + (xy 205.993999 45.263081) (xy 206.037465 45.2588) (xy 209.407222 45.2588) (xy 209.548712 45.40029) (xy 209.404479 45.460033) + (xy 209.267719 45.551413) (xy 209.151413 45.667719) (xy 209.060033 45.804479) (xy 209.017121 45.908078) (xy 209.003299 45.9219) + (xy 207.553033 45.9219) (xy 207.515708 45.918224) (xy 207.478383 45.9219) (xy 207.478375 45.9219) (xy 207.366722 45.932897) + (xy 207.223461 45.976354) (xy 207.091432 46.046926) (xy 206.975707 46.141899) (xy 206.951908 46.170898) (xy 206.468459 46.654348) + (xy 206.406006 46.705601) (xy 206.406002 46.705605) (xy 206.377009 46.729399) (xy 206.353215 46.758392) (xy 204.321609 48.79) + (xy 200.273426 48.79) (xy 200.351185 48.726185) (xy 200.430537 48.629494) (xy 200.489502 48.51918) (xy 200.525812 48.399482) + (xy 200.538072 48.275) (xy 200.535 48.06075) (xy 200.376252 47.902002) (xy 200.535 47.902002) (xy 200.535 47.808592) + (xy 200.66776 47.835) (xy 200.83224 47.835) (xy 200.99356 47.802911) (xy 201.145521 47.739967) (xy 201.282281 47.648587) + (xy 201.398587 47.532281) (xy 201.489967 47.395521) (xy 201.552911 47.24356) (xy 201.585 47.08224) (xy 201.585 46.91776) + (xy 201.552911 46.75644) (xy 201.51 46.652843) (xy 201.51 46.482325) (xy 201.513676 46.445) (xy 201.51 46.407675) + (xy 201.51 46.407667) (xy 201.499003 46.296014) (xy 201.455546 46.152753) (xy 201.384974 46.020724) (xy 201.290001 45.904999) + (xy 201.260998 45.881197) (xy 200.893804 45.514003) (xy 200.870001 45.484999) (xy 200.754276 45.390026) (xy 200.622247 45.319454) + (xy 200.48846 45.278871) (xy 200.430537 45.170506) (xy 200.351185 45.073815) (xy 200.273414 45.00999) (xy 205.374167 45.00999) + ) + ) + (filled_polygon + (pts + (xy 199.227 47.648) (xy 199.247 47.648) (xy 199.247 47.902) (xy 199.227 47.902) (xy 199.227 47.922) + (xy 199.16 47.922) (xy 199.16 47.628) (xy 199.227 47.628) + ) + ) + (filled_polygon + (pts + (xy 123.18575 46.51) (xy 123.7 46.513072) (xy 123.768914 46.506285) (xy 123.235199 47.04) (xy 122.900052 47.04) + (xy 122.909128 47.02302) (xy 122.949727 46.889184) (xy 122.96 46.784877) (xy 122.96 46.784876) (xy 122.963435 46.75) + (xy 122.96 46.715123) (xy 122.96 46.51) (xy 123.027002 46.51) (xy 123.027002 46.351252) + ) + ) + (filled_polygon + (pts + (xy 124.667122 44.591925) (xy 124.710033 44.695523) (xy 124.801413 44.832283) (xy 124.917719 44.948589) (xy 125.054479 45.039969) + (xy 125.182288 45.092909) (xy 124.331285 45.943913) (xy 124.338072 45.875) (xy 124.335 45.66075) (xy 124.17625 45.502) + (xy 123.027 45.502) (xy 123.027 45.522) (xy 122.96 45.522) (xy 122.96 45.228) (xy 123.027 45.228) + (xy 123.027 45.248) (xy 124.17625 45.248) (xy 124.335 45.08925) (xy 124.338072 44.875) (xy 124.325812 44.750518) + (xy 124.289502 44.63082) (xy 124.230537 44.520506) (xy 124.213708 44.5) (xy 124.230537 44.479494) (xy 124.281046 44.385) + (xy 124.460197 44.385) + ) + ) + (filled_polygon + (pts + (xy 151.226699 39.79277) (xy 151.226699 39.95725) (xy 151.242784 40.038115) (xy 151.21918 40.025498) (xy 151.099482 39.989188) + (xy 150.975 39.976928) (xy 150.025 39.976928) (xy 149.900518 39.989188) (xy 149.78082 40.025498) (xy 149.670506 40.084463) + (xy 149.573815 40.163815) (xy 149.494463 40.260506) (xy 149.435498 40.37082) (xy 149.399188 40.490518) (xy 149.386928 40.615) + (xy 149.386928 41.915) (xy 149.399188 42.039482) (xy 149.435498 42.15918) (xy 149.453967 42.193732) (xy 147.407691 44.240008) + (xy 141.962608 44.240008) (xy 141.96 44.213523) (xy 141.96 44.01) (xy 142.027002 44.01) (xy 142.027002 43.851252) + (xy 142.18575 44.01) (xy 142.7 44.013072) (xy 142.824482 44.000812) (xy 142.94418 43.964502) (xy 143.054494 43.905537) + (xy 143.151185 43.826185) (xy 143.230537 43.729494) (xy 143.289502 43.61918) (xy 143.325812 43.499482) (xy 143.338072 43.375) + (xy 143.335 43.16075) (xy 143.17625 43.002) (xy 142.027 43.002) (xy 142.027 43.022) (xy 141.96 43.022) + (xy 141.96 42.728) (xy 142.027 42.728) (xy 142.027 42.748) (xy 143.17625 42.748) (xy 143.298877 42.625373) + (xy 143.322613 42.625373) (xy 143.483933 42.593284) (xy 143.635894 42.53034) (xy 143.772654 42.43896) (xy 143.88896 42.322654) + (xy 143.98034 42.185894) (xy 144.043284 42.033933) (xy 144.075373 41.872613) (xy 144.075373 41.708133) (xy 144.043284 41.546813) + (xy 144.000373 41.443216) (xy 144.000373 41.398306) (xy 144.00405 41.360973) (xy 143.989376 41.211987) (xy 143.945919 41.068726) + (xy 143.923354 41.02651) (xy 143.875347 40.936697) (xy 143.780374 40.820972) (xy 143.751371 40.79717) (xy 143.468204 40.514003) + (xy 143.444401 40.484999) (xy 143.328676 40.390026) (xy 143.280722 40.364394) (xy 143.230537 40.270506) (xy 143.151185 40.173815) + (xy 143.054494 40.094463) (xy 142.94418 40.035498) (xy 142.824482 39.999188) (xy 142.7 39.986928) (xy 141.96 39.986928) + (xy 141.96 39.783277) (xy 141.963435 39.7484) (xy 141.952266 39.635) (xy 151.258082 39.635) + ) + ) + (filled_polygon + (pts + (xy 167.154953 39.196532) (xy 167.255941 39.279411) (xy 167.409686 39.361588) (xy 167.424505 39.366083) (xy 168.29168 40.233259) + (xy 168.319393 40.267027) (xy 168.353161 40.29474) (xy 168.353163 40.294742) (xy 168.411857 40.342911) (xy 168.454151 40.377621) + (xy 168.607897 40.459799) (xy 168.77472 40.510405) (xy 168.904733 40.52321) (xy 168.904741 40.52321) (xy 168.94821 40.527491) + (xy 168.991679 40.52321) (xy 173.771953 40.52321) (xy 173.761928 40.625) (xy 173.761928 40.878957) (xy 173.343263 41.297623) + (xy 173.290943 41.325588) (xy 173.257638 41.35292) (xy 173.24356 41.347089) (xy 173.08224 41.315) (xy 172.91776 41.315) + (xy 172.75644 41.347089) (xy 172.604479 41.410033) (xy 172.467719 41.501413) (xy 172.351413 41.617719) (xy 172.260033 41.754479) + (xy 172.197089 41.90644) (xy 172.165 42.06776) (xy 172.165 42.23224) (xy 172.197089 42.39356) (xy 172.260033 42.545521) + (xy 172.351413 42.682281) (xy 172.467719 42.798587) (xy 172.604479 42.889967) (xy 172.708077 42.932879) (xy 173.161201 43.386002) + (xy 173.184999 43.415001) (xy 173.300724 43.509974) (xy 173.432753 43.580546) (xy 173.533936 43.611239) (xy 172.743563 43.611239) + (xy 170.590526 41.458202) (xy 170.566723 41.429198) (xy 170.450998 41.334225) (xy 170.318969 41.263653) (xy 170.175708 41.220196) + (xy 170.064055 41.209199) (xy 170.064045 41.209199) (xy 170.026722 41.205523) (xy 169.9894 41.209199) (xy 162.453321 41.209199) + (xy 162.415998 41.205523) (xy 162.378676 41.209199) (xy 162.378666 41.209199) (xy 162.339313 41.213075) (xy 162.389502 41.11918) + (xy 162.425812 40.999482) (xy 162.438072 40.875) (xy 162.435 40.66075) (xy 162.276252 40.502002) (xy 162.435 40.502002) + (xy 162.435 40.375) (xy 162.582256 40.375) (xy 162.743576 40.342911) (xy 162.895537 40.279967) (xy 163.032297 40.188587) + (xy 163.148603 40.072281) (xy 163.239983 39.935521) (xy 163.302927 39.78356) (xy 163.335016 39.62224) (xy 163.335016 39.45776) + (xy 163.302927 39.29644) (xy 163.260016 39.192843) (xy 163.260016 39.156838) (xy 163.263692 39.119515) (xy 163.260016 39.082192) + (xy 163.260016 39.082183) (xy 163.249019 38.97053) (xy 163.205562 38.827269) (xy 163.13499 38.69524) (xy 163.040017 38.579515) + (xy 163.011014 38.555713) (xy 162.569304 38.114003) (xy 162.545501 38.084999) (xy 162.429776 37.990026) (xy 162.421246 37.985467) + (xy 162.389502 37.88082) (xy 162.330537 37.770506) (xy 162.251185 37.673815) (xy 162.154494 37.594463) (xy 162.04418 37.535498) + (xy 161.928738 37.500479) (xy 165.458901 37.500479) + ) + ) + (filled_polygon + (pts + (xy 181.744291 42.894093) (xy 181.435603 43.202782) (xy 181.435 43.16075) (xy 181.27625 43.002) (xy 180.127 43.002) + (xy 180.127 43.022) (xy 180.06 43.022) (xy 180.06 42.728) (xy 180.127 42.728) (xy 180.127 42.748) + (xy 181.27625 42.748) (xy 181.435 42.58925) (xy 181.435063 42.584864) + ) + ) + (filled_polygon + (pts + (xy 161.190739 41.414989) (xy 161.127002 41.414989) (xy 161.127002 41.351252) + ) + ) + (filled_polygon + (pts + (xy 161.127 40.248) (xy 161.147 40.248) (xy 161.147 40.502) (xy 161.127 40.502) (xy 161.127 40.522) + (xy 161.06 40.522) (xy 161.06 40.228) (xy 161.127 40.228) + ) + ) + ) + (zone (net 34) (net_name GND) (layer B.Cu) (tstamp 6039FDAA) (hatch edge 0.508) + (connect_pads (clearance 0.508)) + (min_thickness 0.254) + (fill yes (arc_segments 32) (thermal_gap 0.508) (thermal_bridge_width 0.508)) + (polygon + (pts + (xy 80.85 127.25) (xy 92.6 147.85) (xy 138.1 134.85) (xy 187.45 135.3) (xy 226.6 121.7) + (xy 225.8 43.3) (xy 171.5 34.2) (xy 87.6 36.9) (xy 87.95 114.65) + ) + ) + (filled_polygon + (pts + (xy 224.336807 44.116746) (xy 224.447617 44.145115) (xy 224.521481 44.178972) (xy 224.587585 44.224767) (xy 224.644771 44.281261) + (xy 224.691436 44.346768) (xy 224.726105 44.419343) (xy 224.747732 44.497657) (xy 224.758192 44.613012) (xy 224.785002 119.001646) + (xy 215.337562 122.609422) (xy 214.544604 120.543696) (xy 187.343182 130.985343) (xy 188.11806 133.003968) (xy 187.30358 133.315) + (xy 138.158838 133.315) (xy 138.096265 133.314123) (xy 138.058284 133.321126) (xy 138.019845 133.324912) (xy 137.959927 133.343088) + (xy 93.864605 146.047335) (xy 93.520432 145.984758) (xy 93.243912 145.892584) (xy 93.08499 145.756366) (xy 82.933274 128.127044) + (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583074 116.011918) + (xy 88.59798 115.990873) (xy 88.615021 115.952706) (xy 88.618829 115.945648) (xy 88.62876 115.921935) (xy 88.639207 115.898536) + (xy 88.641735 115.890952) (xy 88.657891 115.852374) (xy 88.663024 115.827087) (xy 88.84031 115.29523) (xy 88.855164 115.261034) + (xy 88.868713 115.198522) (xy 88.882908 115.13609) (xy 88.883923 115.098817) (xy 88.948633 114.539922) (xy 88.950347 114.53427) + (xy 88.956379 114.473019) (xy 88.959581 114.44536) (xy 88.959682 114.439478) (xy 88.960257 114.433634) (xy 88.960256 114.405836) + (xy 88.961309 114.344252) (xy 88.960255 114.338437) (xy 88.96016 109.1) (xy 97.761928 109.1) (xy 97.761928 111.1) + (xy 97.774188 111.224482) (xy 97.810498 111.34418) (xy 97.869463 111.454494) (xy 97.948815 111.551185) (xy 98.045506 111.630537) + (xy 98.15582 111.689502) (xy 98.275518 111.725812) (xy 98.4 111.738072) (xy 101.6 111.738072) (xy 101.724482 111.725812) + (xy 101.84418 111.689502) (xy 101.954494 111.630537) (xy 102.051185 111.551185) (xy 102.130537 111.454494) (xy 102.189502 111.34418) + (xy 102.225812 111.224482) (xy 102.238072 111.1) (xy 102.238072 109.1) (xy 102.225812 108.975518) (xy 102.189502 108.85582) + (xy 102.130537 108.745506) (xy 102.051185 108.648815) (xy 101.954494 108.569463) (xy 101.84418 108.510498) (xy 101.724482 108.474188) + (xy 101.6 108.461928) (xy 98.4 108.461928) (xy 98.275518 108.474188) (xy 98.15582 108.510498) (xy 98.045506 108.569463) + (xy 97.948815 108.648815) (xy 97.869463 108.745506) (xy 97.810498 108.85582) (xy 97.774188 108.975518) (xy 97.761928 109.1) + (xy 88.96016 109.1) (xy 88.960076 104.562595) (xy 90.858282 104.562595) (xy 90.902039 104.881675) (xy 91.007205 105.186088) + (xy 91.100186 105.360044) (xy 91.364587 105.455808) (xy 92.320395 104.5) (xy 91.364587 103.544192) (xy 91.100186 103.639956) + (xy 90.959296 103.929571) (xy 90.877616 104.241108) (xy 90.858282 104.562595) (xy 88.960076 104.562595) (xy 88.959885 94.236545) + (xy 88.966261 94.268601) (xy 89.164893 94.748141) (xy 89.453262 95.179715) (xy 89.820285 95.546738) (xy 90.251859 95.835107) + (xy 90.731399 96.033739) (xy 91.240475 96.135) (xy 91.759525 96.135) (xy 92.268601 96.033739) (xy 92.748141 95.835107) + (xy 93.179715 95.546738) (xy 93.546738 95.179715) (xy 93.835107 94.748141) (xy 94.033739 94.268601) (xy 94.135 93.759525) + (xy 94.135 93.240475) (xy 94.033739 92.731399) (xy 93.835107 92.251859) (xy 93.546738 91.820285) (xy 93.179715 91.453262) + (xy 92.748141 91.164893) (xy 92.268601 90.966261) (xy 92.095535 90.931836) (xy 92.271034 90.878599) (xy 92.529014 90.740706) + (xy 92.755134 90.555134) (xy 92.800624 90.499705) (xy 92.969381 90.664176) (xy 93.214382 90.823361) (xy 93.485731 90.93169) + (xy 93.773 90.985) (xy 94.173 90.985) (xy 94.173 89.627) (xy 94.427 89.627) (xy 94.427 90.985) + (xy 94.827 90.985) (xy 95.114269 90.93169) (xy 95.385618 90.823361) (xy 95.630619 90.664176) (xy 95.839857 90.460252) + (xy 96.005291 90.219426) (xy 96.120563 89.950953) (xy 96.141476 89.85689) (xy 96.020155 89.627) (xy 94.427 89.627) + (xy 94.173 89.627) (xy 94.153 89.627) (xy 94.153 89.373) (xy 94.173 89.373) (xy 94.173 88.015) + (xy 94.427 88.015) (xy 94.427 89.373) (xy 96.020155 89.373) (xy 96.141476 89.14311) (xy 96.120563 89.049047) + (xy 96.005291 88.780574) (xy 95.839857 88.539748) (xy 95.630619 88.335824) (xy 95.385618 88.176639) (xy 95.114269 88.06831) + (xy 94.827 88.015) (xy 94.427 88.015) (xy 94.173 88.015) (xy 93.773 88.015) (xy 93.485731 88.06831) + (xy 93.214382 88.176639) (xy 92.969381 88.335824) (xy 92.800624 88.500295) (xy 92.755134 88.444866) (xy 92.529014 88.259294) + (xy 92.271034 88.121401) (xy 91.991111 88.036487) (xy 91.77295 88.015) (xy 90.82705 88.015) (xy 90.608889 88.036487) + (xy 90.547616 88.055074) (xy 90.594443 87.984992) (xy 90.68754 87.760236) (xy 90.735 87.521637) (xy 90.735 87.278363) + (xy 90.68754 87.039764) (xy 90.594443 86.815008) (xy 90.459287 86.612733) (xy 90.371554 86.525) (xy 90.459287 86.437267) + (xy 90.594443 86.234992) (xy 90.68754 86.010236) (xy 90.735 85.771637) (xy 90.735 85.528363) (xy 90.68754 85.289764) + (xy 90.594443 85.065008) (xy 90.547616 84.994926) (xy 90.608889 85.013513) (xy 90.82705 85.035) (xy 91.77295 85.035) + (xy 91.991111 85.013513) (xy 92.271034 84.928599) (xy 92.529014 84.790706) (xy 92.755134 84.605134) (xy 92.800624 84.549705) + (xy 92.969381 84.714176) (xy 93.214382 84.873361) (xy 93.485731 84.98169) (xy 93.773 85.035) (xy 94.173 85.035) + (xy 94.173 83.677) (xy 94.427 83.677) (xy 94.427 85.035) (xy 94.827 85.035) (xy 95.114269 84.98169) + (xy 95.385618 84.873361) (xy 95.630619 84.714176) (xy 95.839857 84.510252) (xy 96.005291 84.269426) (xy 96.120563 84.000953) + (xy 96.141476 83.90689) (xy 96.020155 83.677) (xy 94.427 83.677) (xy 94.173 83.677) (xy 94.153 83.677) + (xy 94.153 83.423) (xy 94.173 83.423) (xy 94.173 82.065) (xy 93.773 82.065) (xy 93.485731 82.11831) + (xy 93.214382 82.226639) (xy 92.969381 82.385824) (xy 92.800624 82.550295) (xy 92.755134 82.494866) (xy 92.529014 82.309294) + (xy 92.271034 82.171401) (xy 91.991111 82.086487) (xy 91.77295 82.065) (xy 90.974885 82.065) (xy 91.042252 82.019987) + (xy 91.269987 81.792252) (xy 91.448918 81.524463) (xy 91.572168 81.226912) (xy 91.635 80.911033) (xy 91.635 80.588967) + (xy 91.572168 80.273088) (xy 91.448918 79.975537) (xy 91.269987 79.707748) (xy 91.042252 79.480013) (xy 90.774463 79.301082) + (xy 90.476912 79.177832) (xy 90.161033 79.115) (xy 89.838967 79.115) (xy 89.523088 79.177832) (xy 89.508624 79.183823) + (xy 89.434999 79.110198) (xy 89.434999 75.792127) (xy 89.741108 75.872384) (xy 90.062595 75.891718) (xy 90.381675 75.847961) + (xy 90.686088 75.742795) (xy 90.860044 75.649814) (xy 90.955808 75.385413) (xy 90 74.429605) (xy 89.985858 74.443748) + (xy 89.806253 74.264143) (xy 89.820395 74.25) (xy 90.179605 74.25) (xy 91.135413 75.205808) (xy 91.399814 75.110044) + (xy 91.540704 74.820429) (xy 91.622384 74.508892) (xy 91.641718 74.187405) (xy 91.597961 73.868325) (xy 91.492795 73.563912) + (xy 91.399814 73.389956) (xy 91.135413 73.294192) (xy 90.179605 74.25) (xy 89.820395 74.25) (xy 89.806253 74.235858) + (xy 89.985858 74.056253) (xy 90 74.070395) (xy 90.955808 73.114587) (xy 90.860044 72.850186) (xy 90.570429 72.709296) + (xy 90.258892 72.627616) (xy 89.937405 72.608282) (xy 89.618325 72.652039) (xy 89.434999 72.715373) (xy 89.434999 51.06104) + (xy 90.957874 49.538166) (xy 90.974344 49.56898) (xy 91.214435 49.63596) (xy 92.000395 48.85) (xy 91.986253 48.835858) + (xy 92.165858 48.656253) (xy 92.18 48.670395) (xy 92.194143 48.656253) (xy 92.373748 48.835858) (xy 92.359605 48.85) + (xy 92.373748 48.864143) (xy 92.194143 49.043748) (xy 92.18 49.029605) (xy 91.39404 49.815565) (xy 91.46102 50.055656) + (xy 91.59676 50.119485) (xy 91.518273 50.151995) (xy 91.289465 50.30488) (xy 91.09488 50.499465) (xy 90.941995 50.728273) + (xy 90.836686 50.98251) (xy 90.783 51.252408) (xy 90.783 51.527592) (xy 90.836686 51.79749) (xy 90.941995 52.051727) + (xy 91.09488 52.280535) (xy 91.289465 52.47512) (xy 91.518273 52.628005) (xy 91.595515 52.66) (xy 91.518273 52.691995) + (xy 91.289465 52.84488) (xy 91.09488 53.039465) (xy 90.941995 53.268273) (xy 90.836686 53.52251) (xy 90.783 53.792408) + (xy 90.783 54.067592) (xy 90.836686 54.33749) (xy 90.941995 54.591727) (xy 91.09488 54.820535) (xy 91.289465 55.01512) + (xy 91.518273 55.168005) (xy 91.595515 55.2) (xy 91.518273 55.231995) (xy 91.289465 55.38488) (xy 91.09488 55.579465) + (xy 90.941995 55.808273) (xy 90.836686 56.06251) (xy 90.783 56.332408) (xy 90.783 56.607592) (xy 90.836686 56.87749) + (xy 90.941995 57.131727) (xy 91.09488 57.360535) (xy 91.289465 57.55512) (xy 91.518273 57.708005) (xy 91.595515 57.74) + (xy 91.518273 57.771995) (xy 91.289465 57.92488) (xy 91.09488 58.119465) (xy 90.941995 58.348273) (xy 90.836686 58.60251) + (xy 90.783 58.872408) (xy 90.783 59.147592) (xy 90.836686 59.41749) (xy 90.941995 59.671727) (xy 91.09488 59.900535) + (xy 91.289465 60.09512) (xy 91.518273 60.248005) (xy 91.595515 60.28) (xy 91.518273 60.311995) (xy 91.289465 60.46488) + (xy 91.09488 60.659465) (xy 90.941995 60.888273) (xy 90.836686 61.14251) (xy 90.783 61.412408) (xy 90.783 61.687592) + (xy 90.836686 61.95749) (xy 90.941995 62.211727) (xy 91.09488 62.440535) (xy 91.289465 62.63512) (xy 91.518273 62.788005) + (xy 91.595515 62.82) (xy 91.518273 62.851995) (xy 91.289465 63.00488) (xy 91.09488 63.199465) (xy 90.941995 63.428273) + (xy 90.836686 63.68251) (xy 90.783 63.952408) (xy 90.783 64.227592) (xy 90.836686 64.49749) (xy 90.941995 64.751727) + (xy 91.09488 64.980535) (xy 91.289465 65.17512) (xy 91.518273 65.328005) (xy 91.595515 65.36) (xy 91.518273 65.391995) + (xy 91.289465 65.54488) (xy 91.09488 65.739465) (xy 90.941995 65.968273) (xy 90.836686 66.22251) (xy 90.783 66.492408) + (xy 90.783 66.767592) (xy 90.836686 67.03749) (xy 90.941995 67.291727) (xy 91.09488 67.520535) (xy 91.289465 67.71512) + (xy 91.518273 67.868005) (xy 91.595515 67.9) (xy 91.518273 67.931995) (xy 91.289465 68.08488) (xy 91.09488 68.279465) + (xy 90.941995 68.508273) (xy 90.836686 68.76251) (xy 90.783 69.032408) (xy 90.783 69.307592) (xy 90.836686 69.57749) + (xy 90.941995 69.831727) (xy 91.09488 70.060535) (xy 91.289465 70.25512) (xy 91.518273 70.408005) (xy 91.77251 70.513314) + (xy 92.042408 70.567) (xy 92.094478 70.567) (xy 92.135501 70.773235) (xy 92.24081 71.027472) (xy 92.393695 71.25628) + (xy 92.58828 71.450865) (xy 92.817088 71.60375) (xy 93.071325 71.709059) (xy 93.341223 71.762745) (xy 93.616407 71.762745) + (xy 93.886305 71.709059) (xy 94.140542 71.60375) (xy 94.36935 71.450865) (xy 94.458056 71.362159) (xy 94.55644 71.402911) + (xy 94.71776 71.435) (xy 94.88224 71.435) (xy 95.04356 71.402911) (xy 95.195521 71.339967) (xy 95.332281 71.248587) + (xy 95.448587 71.132281) (xy 95.539967 70.995521) (xy 95.602911 70.84356) (xy 95.635 70.68224) (xy 95.635 70.51776) + (xy 95.634933 70.517422) (xy 95.677315 70.569065) (xy 95.774006 70.648417) (xy 95.88432 70.707382) (xy 95.94 70.724272) + (xy 95.940001 73.504029) (xy 95.849943 73.564203) (xy 95.664203 73.749943) (xy 95.518268 73.968351) (xy 95.417746 74.211032) + (xy 95.3665 74.468662) (xy 95.3665 74.731338) (xy 95.417746 74.988968) (xy 95.518268 75.231649) (xy 95.664203 75.450057) + (xy 95.849943 75.635797) (xy 96.068351 75.781732) (xy 96.311032 75.882254) (xy 96.568662 75.9335) (xy 96.831338 75.9335) + (xy 97.088968 75.882254) (xy 97.331649 75.781732) (xy 97.4565 75.69831) (xy 97.4565 81.367451) (xy 97.452823 81.404784) + (xy 97.4565 81.442117) (xy 97.466023 81.538799) (xy 97.467497 81.553769) (xy 97.510953 81.69703) (xy 97.581525 81.82906) + (xy 97.648542 81.910719) (xy 97.676499 81.944785) (xy 97.705497 81.968583) (xy 97.804168 82.067254) (xy 97.680967 82.079388) + (xy 96.626606 81.025027) (xy 96.681004 80.943614) (xy 96.781526 80.700933) (xy 96.832772 80.443303) (xy 96.832772 80.180627) + (xy 96.781526 79.922997) (xy 96.681004 79.680316) (xy 96.535069 79.461908) (xy 96.384272 79.311111) (xy 96.384272 79.062819) + (xy 96.535069 78.912022) (xy 96.681004 78.693614) (xy 96.781526 78.450933) (xy 96.832772 78.193303) (xy 96.832772 77.930627) + (xy 96.781526 77.672997) (xy 96.681004 77.430316) (xy 96.535069 77.211908) (xy 96.349329 77.026168) (xy 96.130921 76.880233) + (xy 95.88824 76.779711) (xy 95.63061 76.728465) (xy 95.367934 76.728465) (xy 95.110304 76.779711) (xy 94.867623 76.880233) + (xy 94.649215 77.026168) (xy 94.463475 77.211908) (xy 94.31754 77.430316) (xy 94.217018 77.672997) (xy 94.165772 77.930627) + (xy 94.165772 78.193303) (xy 94.217018 78.450933) (xy 94.31754 78.693614) (xy 94.463475 78.912022) (xy 94.614272 79.062819) + (xy 94.614272 79.311111) (xy 94.463475 79.461908) (xy 94.31754 79.680316) (xy 94.217018 79.922997) (xy 94.165772 80.180627) + (xy 94.165772 80.443303) (xy 94.217018 80.700933) (xy 94.31754 80.943614) (xy 94.463475 81.162022) (xy 94.628323 81.32687) + (xy 94.677684 81.489585) (xy 94.759862 81.643331) (xy 94.84274 81.744318) (xy 94.842743 81.744321) (xy 94.870456 81.778089) + (xy 94.904223 81.805801) (xy 95.28482 82.186398) (xy 95.114269 82.11831) (xy 94.827 82.065) (xy 94.427 82.065) + (xy 94.427 83.423) (xy 96.020155 83.423) (xy 96.141476 83.19311) (xy 96.120563 83.099047) (xy 96.062698 82.964276) + (xy 96.429388 83.330967) (xy 96.407815 83.55) (xy 96.436487 83.841111) (xy 96.521401 84.121034) (xy 96.659294 84.379014) + (xy 96.701935 84.430972) (xy 96.621637 84.415) (xy 96.378363 84.415) (xy 96.139764 84.46246) (xy 95.915008 84.555557) + (xy 95.712733 84.690713) (xy 95.540713 84.862733) (xy 95.405557 85.065008) (xy 95.31246 85.289764) (xy 95.265 85.528363) + (xy 95.265 85.771637) (xy 95.31246 86.010236) (xy 95.405557 86.234992) (xy 95.540713 86.437267) (xy 95.628446 86.525) + (xy 95.540713 86.612733) (xy 95.405557 86.815008) (xy 95.31246 87.039764) (xy 95.265 87.278363) (xy 95.265 87.521637) + (xy 95.31246 87.760236) (xy 95.405557 87.984992) (xy 95.540713 88.187267) (xy 95.712733 88.359287) (xy 95.915008 88.494443) + (xy 96.139764 88.58754) (xy 96.378363 88.635) (xy 96.621637 88.635) (xy 96.701935 88.619028) (xy 96.659294 88.670986) + (xy 96.521401 88.928966) (xy 96.436487 89.208889) (xy 96.407815 89.5) (xy 96.436487 89.791111) (xy 96.521401 90.071034) + (xy 96.659294 90.329014) (xy 96.844866 90.555134) (xy 97.070986 90.740706) (xy 97.328966 90.878599) (xy 97.608889 90.963513) + (xy 97.82705 90.985) (xy 98.77295 90.985) (xy 98.991111 90.963513) (xy 99.271034 90.878599) (xy 99.529014 90.740706) + (xy 99.755134 90.555134) (xy 99.940706 90.329014) (xy 100.078599 90.071034) (xy 100.163513 89.791111) (xy 100.192185 89.5) + (xy 100.166085 89.235) (xy 100.27295 89.235) (xy 100.491111 89.213513) (xy 100.615011 89.175928) (xy 100.615011 92.810187) + (xy 92.991376 100.433823) (xy 92.976912 100.427832) (xy 92.661033 100.365) (xy 92.338967 100.365) (xy 92.023088 100.427832) + (xy 91.725537 100.551082) (xy 91.457748 100.730013) (xy 91.230013 100.957748) (xy 91.051082 101.225537) (xy 90.927832 101.523088) + (xy 90.865 101.838967) (xy 90.865 102.161033) (xy 90.927832 102.476912) (xy 91.051082 102.774463) (xy 91.230013 103.042252) + (xy 91.457748 103.269987) (xy 91.554935 103.334925) (xy 91.544192 103.364587) (xy 92.5 104.320395) (xy 92.514143 104.306253) + (xy 92.693748 104.485858) (xy 92.679605 104.5) (xy 92.693748 104.514143) (xy 92.514143 104.693748) (xy 92.5 104.679605) + (xy 91.544192 105.635413) (xy 91.554935 105.665075) (xy 91.457748 105.730013) (xy 91.230013 105.957748) (xy 91.051082 106.225537) + (xy 90.927832 106.523088) (xy 90.865 106.838967) (xy 90.865 107.161033) (xy 90.927832 107.476912) (xy 91.051082 107.774463) + (xy 91.230013 108.042252) (xy 91.457748 108.269987) (xy 91.725537 108.448918) (xy 92.023088 108.572168) (xy 92.338967 108.635) + (xy 92.661033 108.635) (xy 92.976912 108.572168) (xy 93.274463 108.448918) (xy 93.542252 108.269987) (xy 93.769987 108.042252) + (xy 93.948918 107.774463) (xy 94.072168 107.476912) (xy 94.135 107.161033) (xy 94.135 106.838967) (xy 94.072168 106.523088) + (xy 94.066177 106.508624) (xy 94.335998 106.238803) (xy 94.365002 106.215) (xy 94.459975 106.099275) (xy 94.530547 105.967246) + (xy 94.574004 105.823985) (xy 94.585001 105.712332) (xy 94.585001 105.712323) (xy 94.588677 105.675) (xy 94.585001 105.637677) + (xy 94.585001 101.62621) (xy 97.761928 98.449283) (xy 97.761928 99.9) (xy 97.774188 100.024482) (xy 97.810498 100.14418) + (xy 97.869463 100.254494) (xy 97.948815 100.351185) (xy 98.045506 100.430537) (xy 98.15582 100.489502) (xy 98.275518 100.525812) + (xy 98.4 100.538072) (xy 101.6 100.538072) (xy 101.724482 100.525812) (xy 101.84418 100.489502) (xy 101.954494 100.430537) + (xy 102.051185 100.351185) (xy 102.130537 100.254494) (xy 102.189502 100.14418) (xy 102.225812 100.024482) (xy 102.238072 99.9) + (xy 102.238072 97.9) (xy 102.225812 97.775518) (xy 102.189502 97.65582) (xy 102.130537 97.545506) (xy 102.051185 97.448815) + (xy 101.954494 97.369463) (xy 101.84418 97.310498) (xy 101.724482 97.274188) (xy 101.6 97.261928) (xy 98.949283 97.261928) + (xy 99.686211 96.525) (xy 103.936928 96.525) (xy 103.936928 97.475) (xy 103.949188 97.599482) (xy 103.985498 97.71918) + (xy 104.044463 97.829494) (xy 104.123815 97.926185) (xy 104.220506 98.005537) (xy 104.33082 98.064502) (xy 104.450518 98.100812) + (xy 104.575 98.113072) (xy 105.875 98.113072) (xy 105.999482 98.100812) (xy 106.11918 98.064502) (xy 106.229494 98.005537) + (xy 106.326185 97.926185) (xy 106.405537 97.829494) (xy 106.410964 97.819341) (xy 106.49356 97.802911) (xy 106.645521 97.739967) + (xy 106.782281 97.648587) (xy 106.898587 97.532281) (xy 106.989967 97.395521) (xy 107.052911 97.24356) (xy 107.085 97.08224) + (xy 107.085 96.91776) (xy 107.052911 96.75644) (xy 106.989967 96.604479) (xy 106.898587 96.467719) (xy 106.782281 96.351413) + (xy 106.645521 96.260033) (xy 106.49356 96.197089) (xy 106.410964 96.180659) (xy 106.405537 96.170506) (xy 106.326185 96.073815) + (xy 106.292053 96.045804) (xy 106.740475 96.135) (xy 107.259525 96.135) (xy 107.707947 96.045804) (xy 107.673815 96.073815) + (xy 107.594463 96.170506) (xy 107.535498 96.28082) (xy 107.499188 96.400518) (xy 107.486928 96.525) (xy 107.486928 96.988271) + (xy 107.483077 96.992121) (xy 107.379479 97.035033) (xy 107.242719 97.126413) (xy 107.126413 97.242719) (xy 107.035033 97.379479) + (xy 106.992122 97.483077) (xy 106.489002 97.986197) (xy 106.459999 98.009999) (xy 106.42023 98.058458) (xy 106.365026 98.125724) + (xy 106.308088 98.232247) (xy 106.294454 98.257754) (xy 106.250997 98.401015) (xy 106.24 98.512668) (xy 106.24 98.512678) + (xy 106.236324 98.55) (xy 106.24 98.587323) (xy 106.240001 100.545091) (xy 106.225537 100.551082) (xy 105.957748 100.730013) + (xy 105.730013 100.957748) (xy 105.551082 101.225537) (xy 105.427832 101.523088) (xy 105.365 101.838967) (xy 105.365 102.161033) + (xy 105.427832 102.476912) (xy 105.551082 102.774463) (xy 105.730013 103.042252) (xy 105.957748 103.269987) (xy 106.225537 103.448918) + (xy 106.523088 103.572168) (xy 106.838967 103.635) (xy 107.161033 103.635) (xy 107.476912 103.572168) (xy 107.774463 103.448918) + (xy 108.042252 103.269987) (xy 108.269987 103.042252) (xy 108.448918 102.774463) (xy 108.572168 102.476912) (xy 108.635 102.161033) + (xy 108.635 101.838967) (xy 108.572168 101.523088) (xy 108.448918 101.225537) (xy 108.269987 100.957748) (xy 108.042252 100.730013) + (xy 107.774463 100.551082) (xy 107.76 100.545091) (xy 107.76 98.864801) (xy 108.066923 98.557878) (xy 108.170521 98.514967) + (xy 108.307281 98.423587) (xy 108.423587 98.307281) (xy 108.514967 98.170521) (xy 108.538763 98.113072) (xy 109.425 98.113072) + (xy 109.549482 98.100812) (xy 109.66918 98.064502) (xy 109.779494 98.005537) (xy 109.876185 97.926185) (xy 109.955537 97.829494) + (xy 110.014502 97.71918) (xy 110.050812 97.599482) (xy 110.063072 97.475) (xy 110.063072 96.525) (xy 110.050812 96.400518) + (xy 110.014502 96.28082) (xy 109.955537 96.170506) (xy 109.876185 96.073815) (xy 109.779494 95.994463) (xy 109.66918 95.935498) + (xy 109.549482 95.899188) (xy 109.425 95.886928) (xy 108.125 95.886928) (xy 108.122421 95.887182) (xy 108.248141 95.835107) + (xy 108.679715 95.546738) (xy 109.046738 95.179715) (xy 109.335107 94.748141) (xy 109.533739 94.268601) (xy 109.635 93.759525) + (xy 109.635 93.240475) (xy 109.533739 92.731399) (xy 109.335107 92.251859) (xy 109.046738 91.820285) (xy 108.679715 91.453262) + (xy 108.248141 91.164893) (xy 107.768601 90.966261) (xy 107.259525 90.865) (xy 106.740475 90.865) (xy 106.231399 90.966261) + (xy 105.751859 91.164893) (xy 105.320285 91.453262) (xy 104.953262 91.820285) (xy 104.664893 92.251859) (xy 104.466261 92.731399) + (xy 104.365 93.240475) (xy 104.365 93.759525) (xy 104.466261 94.268601) (xy 104.664893 94.748141) (xy 104.953262 95.179715) + (xy 105.320285 95.546738) (xy 105.751859 95.835107) (xy 105.877579 95.887182) (xy 105.875 95.886928) (xy 104.575 95.886928) + (xy 104.450518 95.899188) (xy 104.33082 95.935498) (xy 104.220506 95.994463) (xy 104.123815 96.073815) (xy 104.044463 96.170506) + (xy 103.985498 96.28082) (xy 103.949188 96.400518) (xy 103.936928 96.525) (xy 99.686211 96.525) (xy 105.810993 90.400219) + (xy 105.839991 90.376421) (xy 105.883871 90.322953) (xy 105.934964 90.260697) (xy 106.005536 90.128667) (xy 106.019996 90.080997) + (xy 106.048993 89.985406) (xy 106.05999 89.873753) (xy 106.05999 89.873744) (xy 106.063666 89.836421) (xy 106.05999 89.799098) + (xy 106.05999 88.171683) (xy 106.22651 88.222197) (xy 106.36362 88.235701) (xy 106.40151 88.247195) (xy 106.436846 88.250675) + (xy 106.498815 88.326185) (xy 106.595506 88.405537) (xy 106.70582 88.464502) (xy 106.825518 88.500812) (xy 106.95 88.513072) + (xy 108.95 88.513072) (xy 109.074482 88.500812) (xy 109.19418 88.464502) (xy 109.304494 88.405537) (xy 109.401185 88.326185) + (xy 109.476015 88.235004) (xy 109.48224 88.235004) (xy 109.64356 88.202915) (xy 109.795521 88.139971) (xy 109.932281 88.048591) + (xy 110.048587 87.932285) (xy 110.139967 87.795525) (xy 110.202911 87.643564) (xy 110.235 87.482244) (xy 110.235 87.317764) + (xy 110.202911 87.156444) (xy 110.16 87.052847) (xy 110.16 86.385) (xy 112.127843 86.385) (xy 112.23144 86.427911) + (xy 112.39276 86.46) (xy 112.55724 86.46) (xy 112.71856 86.427911) (xy 112.870521 86.364967) (xy 113.007281 86.273587) + (xy 113.123587 86.157281) (xy 113.214967 86.020521) (xy 113.277911 85.86856) (xy 113.31 85.70724) (xy 113.31 85.54276) + (xy 113.277911 85.38144) (xy 113.214967 85.229479) (xy 113.123587 85.092719) (xy 113.007281 84.976413) (xy 112.870521 84.885033) + (xy 112.71856 84.822089) (xy 112.55724 84.79) (xy 112.39276 84.79) (xy 112.23144 84.822089) (xy 112.127843 84.865) + (xy 111.968895 84.865) (xy 112.051614 84.782281) (xy 112.142994 84.645521) (xy 112.205938 84.49356) (xy 112.238027 84.33224) + (xy 112.238027 84.16776) (xy 112.205938 84.00644) (xy 112.142994 83.854479) (xy 112.051614 83.717719) (xy 111.935308 83.601413) + (xy 111.798548 83.510033) (xy 111.646587 83.447089) (xy 111.485267 83.415) (xy 111.320787 83.415) (xy 111.159467 83.447089) + (xy 111.05587 83.49) (xy 108.897157 83.49) (xy 108.79356 83.447089) (xy 108.63224 83.415) (xy 108.46776 83.415) + (xy 108.30644 83.447089) (xy 108.154479 83.510033) (xy 108.017719 83.601413) (xy 107.901413 83.717719) (xy 107.810033 83.854479) + (xy 107.747089 84.00644) (xy 107.715 84.16776) (xy 107.715 84.33224) (xy 107.74577 84.486928) (xy 107.285 84.486928) + (xy 107.285 83.390819) (xy 107.36441 83.294058) (xy 107.446588 83.140313) (xy 107.497194 82.97349) (xy 107.51428 82.8) + (xy 107.497194 82.62651) (xy 107.458839 82.500072) (xy 108.10898 82.500072) (xy 108.171688 82.53359) (xy 108.338511 82.584196) + (xy 108.468524 82.597001) (xy 108.468534 82.597001) (xy 108.512 82.601282) (xy 108.555466 82.597001) (xy 114.295423 82.597001) + (xy 114.713355 83.014933) (xy 114.604473 83.060033) (xy 114.467713 83.151413) (xy 114.351407 83.267719) (xy 114.260027 83.404479) + (xy 114.197083 83.55644) (xy 114.164994 83.71776) (xy 114.164994 83.88224) (xy 114.197083 84.04356) (xy 114.239995 84.147159) + (xy 114.239994 84.962671) (xy 114.236318 84.999994) (xy 114.239994 85.037316) (xy 114.239994 85.037326) (xy 114.250991 85.148979) + (xy 114.281792 85.250518) (xy 114.294448 85.29224) (xy 114.36502 85.42427) (xy 114.404865 85.47282) (xy 114.459993 85.539995) + (xy 114.488997 85.563798) (xy 115.440198 86.515) (xy 115.263891 86.515) (xy 114.957673 86.575911) (xy 114.669221 86.695391) + (xy 114.409621 86.86885) (xy 114.18885 87.089621) (xy 114.015391 87.349221) (xy 113.895911 87.637673) (xy 113.835 87.943891) + (xy 113.835 88.256109) (xy 113.895911 88.562327) (xy 114.015391 88.850779) (xy 114.18885 89.110379) (xy 114.409621 89.33115) + (xy 114.669221 89.504609) (xy 114.835016 89.573283) (xy 114.797988 89.628699) (xy 114.637047 90.017245) (xy 114.555 90.429722) + (xy 114.555 90.85028) (xy 114.637047 91.262757) (xy 114.769252 91.581928) (xy 114.23673 91.581928) (xy 112.968804 90.314003) + (xy 112.945001 90.284999) (xy 112.829276 90.190026) (xy 112.697247 90.119454) (xy 112.553986 90.075997) (xy 112.442333 90.065) + (xy 112.442322 90.065) (xy 112.405 90.061324) (xy 112.367678 90.065) (xy 111.585 90.065) (xy 111.585 89.957972) + (xy 111.61001 89.83224) (xy 111.61001 89.66776) (xy 111.577921 89.50644) (xy 111.514977 89.354479) (xy 111.423597 89.217719) + (xy 111.307291 89.101413) (xy 111.170531 89.010033) (xy 111.01857 88.947089) (xy 110.85725 88.915) (xy 110.69277 88.915) + (xy 110.53145 88.947089) (xy 110.379489 89.010033) (xy 110.242729 89.101413) (xy 110.126423 89.217719) (xy 110.035043 89.354479) + (xy 109.972099 89.50644) (xy 109.94001 89.66776) (xy 109.94001 89.83224) (xy 109.972099 89.99356) (xy 110.035043 90.145521) + (xy 110.065001 90.190356) (xy 110.065 90.787667) (xy 110.061323 90.825) (xy 110.065 90.862332) (xy 110.065001 105.360197) + (xy 109.185199 106.24) (xy 108.454909 106.24) (xy 108.448918 106.225537) (xy 108.269987 105.957748) (xy 108.042252 105.730013) + (xy 107.774463 105.551082) (xy 107.476912 105.427832) (xy 107.161033 105.365) (xy 106.838967 105.365) (xy 106.523088 105.427832) + (xy 106.225537 105.551082) (xy 105.957748 105.730013) (xy 105.730013 105.957748) (xy 105.551082 106.225537) (xy 105.427832 106.523088) + (xy 105.365 106.838967) (xy 105.365 107.161033) (xy 105.427832 107.476912) (xy 105.551082 107.774463) (xy 105.730013 108.042252) + (xy 105.957748 108.269987) (xy 106.225537 108.448918) (xy 106.523088 108.572168) (xy 106.838967 108.635) (xy 107.161033 108.635) + (xy 107.476912 108.572168) (xy 107.774463 108.448918) (xy 108.042252 108.269987) (xy 108.269987 108.042252) (xy 108.448918 107.774463) + (xy 108.454909 107.76) (xy 109.462678 107.76) (xy 109.5 107.763676) (xy 109.537322 107.76) (xy 109.537333 107.76) + (xy 109.648986 107.749003) (xy 109.792247 107.705546) (xy 109.924276 107.634974) (xy 110.040001 107.540001) (xy 110.063804 107.510997) + (xy 110.065 107.509801) (xy 110.065001 110.287668) (xy 110.061324 110.325) (xy 110.065001 110.362333) (xy 110.075998 110.473986) + (xy 110.083006 110.497089) (xy 110.119454 110.617246) (xy 110.190026 110.749276) (xy 110.24 110.810169) (xy 110.240001 111.462668) + (xy 110.236324 111.5) (xy 110.240001 111.537333) (xy 110.250998 111.648986) (xy 110.254444 111.660345) (xy 110.294454 111.792246) + (xy 110.365026 111.924276) (xy 110.432361 112.006323) (xy 110.46 112.040001) (xy 110.488998 112.063799) (xy 110.967122 112.541923) + (xy 111.010033 112.645521) (xy 111.101413 112.782281) (xy 111.217719 112.898587) (xy 111.354479 112.989967) (xy 111.50644 113.052911) + (xy 111.66776 113.085) (xy 111.83224 113.085) (xy 111.99356 113.052911) (xy 112.04 113.033675) (xy 112.04 114.212679) + (xy 112.036324 114.250002) (xy 112.04 114.287324) (xy 112.04 114.287334) (xy 112.050997 114.398987) (xy 112.087547 114.519479) + (xy 112.094454 114.542248) (xy 112.165026 114.674278) (xy 112.194342 114.709999) (xy 112.259999 114.790003) (xy 112.289002 114.813805) + (xy 112.961204 115.486009) (xy 112.984998 115.515002) (xy 113.013991 115.538796) (xy 113.013995 115.5388) (xy 113.075059 115.588913) + (xy 113.100723 115.609975) (xy 113.232752 115.680547) (xy 113.376013 115.724004) (xy 113.487666 115.735001) (xy 113.487675 115.735001) + (xy 113.524998 115.738677) (xy 113.562321 115.735001) (xy 126.487677 115.735001) (xy 126.524999 115.738677) (xy 126.562321 115.735001) + (xy 126.562332 115.735001) (xy 126.673985 115.724004) (xy 126.817246 115.680547) (xy 126.949275 115.609975) (xy 127.065 115.515002) + (xy 127.088803 115.485999) (xy 128.011003 114.563799) (xy 128.040001 114.540001) (xy 128.130241 114.430043) (xy 129.356728 115.656531) + (xy 129.357689 115.66136) (xy 129.390926 115.741602) (xy 111.938924 115.741602) (xy 111.901601 115.737926) (xy 111.864278 115.741602) + (xy 111.864269 115.741602) (xy 111.752616 115.752599) (xy 111.609355 115.796056) (xy 111.477326 115.866628) (xy 111.361601 115.961601) + (xy 111.337803 115.990599) (xy 109.088403 118.24) (xy 108.037322 118.24) (xy 107.999999 118.236324) (xy 107.962676 118.24) + (xy 107.962667 118.24) (xy 107.851014 118.250997) (xy 107.709118 118.29404) (xy 107.707753 118.294454) (xy 107.575723 118.365026) + (xy 107.499176 118.427847) (xy 107.459999 118.459999) (xy 107.436201 118.488997) (xy 105.740026 120.185172) (xy 105.870288 119.870692) + (xy 105.985 119.293997) (xy 105.985 118.706003) (xy 105.870288 118.129308) (xy 105.645273 117.586072) (xy 105.318601 117.097174) + (xy 104.902826 116.681399) (xy 104.413928 116.354727) (xy 103.870692 116.129712) (xy 103.293997 116.015) (xy 102.706003 116.015) + (xy 102.129308 116.129712) (xy 101.586072 116.354727) (xy 101.097174 116.681399) (xy 100.681399 117.097174) (xy 100.354727 117.586072) + (xy 100.129712 118.129308) (xy 100.015 118.706003) (xy 100.015 119.293997) (xy 100.129712 119.870692) (xy 100.354727 120.413928) + (xy 100.681399 120.902826) (xy 100.843372 121.064799) (xy 98.662127 121.064799) (xy 98.624804 121.061123) (xy 98.587481 121.064799) + (xy 98.587472 121.064799) (xy 98.475819 121.075796) (xy 98.332558 121.119253) (xy 98.200529 121.189825) (xy 98.084804 121.284798) + (xy 98.061006 121.313797) (xy 97.407504 121.967299) (xy 97.407499 121.967303) (xy 90.226377 129.148426) (xy 90.196703 129.107016) + (xy 90.105409 129.021509) (xy 89.999187 128.955457) (xy 89.88212 128.911396) (xy 89.758707 128.89102) (xy 89.63369 128.895113) + (xy 89.511873 128.923516) (xy 89.397939 128.97514) (xy 87.665889 129.97514) (xy 87.564215 130.047998) (xy 87.478708 130.139292) + (xy 87.412656 130.245514) (xy 87.368595 130.362581) (xy 87.348219 130.485994) (xy 87.352312 130.611011) (xy 87.380715 130.732828) + (xy 87.432338 130.846762) (xy 87.833394 131.54141) (xy 87.761998 131.612806) (xy 87.733 131.636604) (xy 87.709202 131.665602) + (xy 87.709201 131.665603) (xy 87.638026 131.752329) (xy 87.567454 131.884359) (xy 87.543131 131.964546) (xy 87.523998 132.027619) + (xy 87.519847 132.06976) (xy 87.509324 132.176605) (xy 87.513001 132.213937) (xy 87.513 132.937842) (xy 87.470089 133.04144) + (xy 87.438 133.20276) (xy 87.438 133.36724) (xy 87.470089 133.52856) (xy 87.533033 133.680521) (xy 87.624413 133.817281) + (xy 87.740719 133.933587) (xy 87.877479 134.024967) (xy 88.02944 134.087911) (xy 88.19076 134.12) (xy 88.35524 134.12) + (xy 88.51656 134.087911) (xy 88.668521 134.024967) (xy 88.805281 133.933587) (xy 88.905591 133.833277) (xy 88.905591 133.950574) + (xy 88.987638 134.363051) (xy 89.148579 134.751597) (xy 89.382228 135.101278) (xy 89.679608 135.398658) (xy 90.029289 135.632307) + (xy 90.417835 135.793248) (xy 90.830312 135.875295) (xy 91.25087 135.875295) (xy 91.663347 135.793248) (xy 92.051893 135.632307) + (xy 92.401574 135.398658) (xy 92.698954 135.101278) (xy 92.932603 134.751597) (xy 93.093544 134.363051) (xy 93.175591 133.950574) + (xy 93.175591 133.530016) (xy 93.157187 133.437493) (xy 93.228051 133.423397) (xy 93.616597 133.262456) (xy 93.966278 133.028807) + (xy 94.066086 132.928999) (xy 94.025 133.135551) (xy 94.025 133.664449) (xy 94.128183 134.183186) (xy 94.330583 134.671825) + (xy 94.624424 135.111588) (xy 94.998412 135.485576) (xy 95.438175 135.779417) (xy 95.780957 135.921401) (xy 95.403993 136.077545) + (xy 95.054312 136.311194) (xy 94.907159 136.458347) (xy 94.591893 136.247693) (xy 94.203347 136.086752) (xy 93.79087 136.004705) + (xy 93.370312 136.004705) (xy 92.957835 136.086752) (xy 92.569289 136.247693) (xy 92.219608 136.481342) (xy 91.922228 136.778722) + (xy 91.688579 137.128403) (xy 91.527638 137.516949) (xy 91.445591 137.929426) (xy 91.445591 138.349984) (xy 91.527638 138.762461) + (xy 91.688579 139.151007) (xy 91.922228 139.500688) (xy 92.219608 139.798068) (xy 92.569289 140.031717) (xy 92.957835 140.192658) + (xy 93.370312 140.274705) (xy 93.79087 140.274705) (xy 94.203347 140.192658) (xy 94.591893 140.031717) (xy 94.941574 139.798068) + (xy 95.088727 139.650915) (xy 95.403993 139.861569) (xy 95.792539 140.02251) (xy 95.933558 140.050561) (xy 95.918299 140.091104) + (xy 95.897923 140.214517) (xy 95.902016 140.339534) (xy 95.930419 140.461351) (xy 95.982042 140.575285) (xy 97.132042 142.567143) + (xy 97.204901 142.668817) (xy 97.296195 142.754324) (xy 97.402417 142.820376) (xy 97.519484 142.864437) (xy 97.642897 142.884813) + (xy 97.767914 142.88072) (xy 97.889731 142.852317) (xy 98.003665 142.800693) (xy 99.735715 141.800693) (xy 99.837389 141.727835) + (xy 99.922896 141.636541) (xy 99.988948 141.530319) (xy 100.033009 141.413252) (xy 100.053385 141.289839) (xy 100.049292 141.164822) + (xy 100.020889 141.043005) (xy 99.969266 140.929071) (xy 99.494905 140.107454) (xy 99.522 139.97124) (xy 99.522 139.80676) + (xy 99.489911 139.64544) (xy 99.426967 139.493479) (xy 99.354089 139.384409) (xy 99.406109 139.384409) (xy 99.712327 139.323498) + (xy 100.000779 139.204018) (xy 100.260379 139.030559) (xy 100.48115 138.809788) (xy 100.654609 138.550188) (xy 100.774089 138.261736) + (xy 100.835 137.955518) (xy 100.835 137.6433) (xy 100.774089 137.337082) (xy 100.654609 137.04863) (xy 100.48115 136.78903) + (xy 100.260379 136.568259) (xy 100.257868 136.566581) (xy 100.113475 136.350482) (xy 99.906632 136.143639) (xy 99.663411 135.981124) + (xy 99.393158 135.869182) (xy 99.10626 135.812114) (xy 98.81374 135.812114) (xy 98.526842 135.869182) (xy 98.256589 135.981124) + (xy 98.013368 136.143639) (xy 97.811046 136.345962) (xy 97.776278 136.311194) (xy 97.426597 136.077545) (xy 97.292069 136.021822) + (xy 97.493186 135.981817) (xy 97.981825 135.779417) (xy 98.421588 135.485576) (xy 98.795576 135.111588) (xy 99.089417 134.671825) + (xy 99.291817 134.183186) (xy 99.395 133.664449) (xy 99.395 133.135551) (xy 99.372733 133.023608) (xy 99.736974 133.654492) + (xy 99.751434 133.686405) (xy 99.771841 133.714883) (xy 99.771846 133.714892) (xy 99.832896 133.800088) (xy 99.934974 133.895694) + (xy 100.053741 133.969548) (xy 100.184635 134.018813) (xy 100.322625 134.041595) (xy 100.322626 134.041595) (xy 100.462407 134.037019) + (xy 100.598612 134.005261) (xy 100.694081 133.962004) (xy 100.694082 133.962004) (xy 100.726003 133.94754) (xy 100.754489 133.927127) + (xy 100.969143 133.803197) (xy 101.329768 134.427817) (xy 101.402626 134.529491) (xy 101.49392 134.614997) (xy 101.600142 134.68105) + (xy 101.717209 134.725111) (xy 101.840622 134.745487) (xy 101.869732 134.744534) (xy 102.636205 135.511008) (xy 102.659999 135.540001) + (xy 102.688992 135.563795) (xy 102.688996 135.563799) (xy 102.759685 135.621811) (xy 102.775724 135.634974) (xy 102.907753 135.705546) + (xy 103.051014 135.749003) (xy 103.162667 135.76) (xy 103.162676 135.76) (xy 103.199999 135.763676) (xy 103.237322 135.76) + (xy 103.975864 135.76) (xy 104.013186 135.763676) (xy 104.050508 135.76) (xy 104.050519 135.76) (xy 104.162172 135.749003) + (xy 104.305433 135.705546) (xy 104.437462 135.634974) (xy 104.553187 135.540001) (xy 104.57699 135.510998) (xy 105.295532 134.792456) + (xy 105.376094 134.776431) (xy 105.528055 134.713487) (xy 105.664815 134.622107) (xy 105.781121 134.505801) (xy 105.872501 134.369041) + (xy 105.935445 134.21708) (xy 105.954744 134.120057) (xy 107.54 132.534801) (xy 107.54 132.981451) (xy 107.536324 133.018774) + (xy 107.54 133.056096) (xy 107.54 133.056106) (xy 107.550997 133.167759) (xy 107.588409 133.291091) (xy 107.594454 133.31102) + (xy 107.665026 133.44305) (xy 107.686954 133.469769) (xy 107.759999 133.558775) (xy 107.789003 133.582578) (xy 111.126814 136.92039) + (xy 111.150612 136.949388) (xy 111.17961 136.973186) (xy 111.266336 137.044361) (xy 111.398366 137.114933) (xy 111.541627 137.15839) + (xy 111.65328 137.169387) (xy 111.65329 137.169387) (xy 111.690613 137.173063) (xy 111.727936 137.169387) (xy 122.953291 137.169387) + (xy 122.990613 137.173063) (xy 123.027935 137.169387) (xy 123.027946 137.169387) (xy 123.139599 137.15839) (xy 123.28286 137.114933) + (xy 123.414889 137.044361) (xy 123.530614 136.949388) (xy 123.554417 136.920384) (xy 127.214802 133.26) (xy 137.704478 133.26) + (xy 137.7418 133.263676) (xy 137.779122 133.26) (xy 137.779133 133.26) (xy 137.890786 133.249003) (xy 138.034047 133.205546) + (xy 138.166076 133.134974) (xy 138.281801 133.040001) (xy 138.305604 133.010997) (xy 140.307866 131.008736) (xy 140.305089 131.01544) + (xy 140.273 131.17676) (xy 140.273 131.34124) (xy 140.305089 131.50256) (xy 140.368033 131.654521) (xy 140.459413 131.791281) + (xy 140.575719 131.907587) (xy 140.712479 131.998967) (xy 140.86444 132.061911) (xy 141.02576 132.094) (xy 141.19024 132.094) + (xy 141.35156 132.061911) (xy 141.455157 132.019) (xy 142.504792 132.019) (xy 142.514889 132.06976) (xy 142.577833 132.221721) + (xy 142.669213 132.358481) (xy 142.785519 132.474787) (xy 142.922279 132.566167) (xy 143.07424 132.629111) (xy 143.23556 132.6612) + (xy 143.40004 132.6612) (xy 143.56136 132.629111) (xy 143.713321 132.566167) (xy 143.850081 132.474787) (xy 143.966387 132.358481) + (xy 144.057767 132.221721) (xy 144.100679 132.118122) (xy 146.629812 129.58899) (xy 146.983584 129.58899) (xy 146.985289 129.59756) + (xy 147.048233 129.749521) (xy 147.139613 129.886281) (xy 147.255919 130.002587) (xy 147.392679 130.093967) (xy 147.54464 130.156911) + (xy 147.70596 130.189) (xy 147.87044 130.189) (xy 148.03176 130.156911) (xy 148.135357 130.114) (xy 162.81368 130.114) + (xy 162.851002 130.117676) (xy 162.888324 130.114) (xy 162.888335 130.114) (xy 162.999988 130.103003) (xy 163.143249 130.059546) + (xy 163.275278 129.988974) (xy 163.391003 129.894001) (xy 163.414806 129.864997) (xy 166.454221 126.825583) (xy 166.539813 126.953681) + (xy 166.656119 127.069987) (xy 166.792879 127.161367) (xy 166.94484 127.224311) (xy 167.10616 127.2564) (xy 167.27064 127.2564) + (xy 167.43196 127.224311) (xy 167.583921 127.161367) (xy 167.720681 127.069987) (xy 167.836987 126.953681) (xy 167.928367 126.816921) + (xy 167.971279 126.713322) (xy 170.935 123.749602) (xy 170.935 123.956109) (xy 170.995911 124.262327) (xy 171.115391 124.550779) + (xy 171.28885 124.810379) (xy 171.509621 125.03115) (xy 171.769221 125.204609) (xy 171.935016 125.273283) (xy 171.897988 125.328699) + (xy 171.737047 125.717245) (xy 171.655 126.129722) (xy 171.655 126.55028) (xy 171.737047 126.962757) (xy 171.869252 127.281928) + (xy 170.75 127.281928) (xy 170.625518 127.294188) (xy 170.50582 127.330498) (xy 170.395506 127.389463) (xy 170.298815 127.468815) + (xy 170.219463 127.565506) (xy 170.160498 127.67582) (xy 170.124188 127.795518) (xy 170.111928 127.92) (xy 170.111928 129.92) + (xy 170.124188 130.044482) (xy 170.160498 130.16418) (xy 170.219463 130.274494) (xy 170.298815 130.371185) (xy 170.395506 130.450537) + (xy 170.50582 130.509502) (xy 170.625518 130.545812) (xy 170.75 130.558072) (xy 172.46327 130.558072) (xy 173.404201 131.499003) + (xy 173.427999 131.528001) (xy 173.543724 131.622974) (xy 173.675753 131.693546) (xy 173.819014 131.737003) (xy 173.930667 131.748) + (xy 173.930675 131.748) (xy 173.968 131.751676) (xy 174.005325 131.748) (xy 176.955843 131.748) (xy 177.05944 131.790911) + (xy 177.22076 131.823) (xy 177.253424 131.823) (xy 177.262089 131.86656) (xy 177.325033 132.018521) (xy 177.416413 132.155281) + (xy 177.532719 132.271587) (xy 177.669479 132.362967) (xy 177.82144 132.425911) (xy 177.98276 132.458) (xy 178.14724 132.458) + (xy 178.30856 132.425911) (xy 178.412157 132.383) (xy 180.569678 132.383) (xy 180.607 132.386676) (xy 180.644322 132.383) + (xy 180.644333 132.383) (xy 180.755986 132.372003) (xy 180.899247 132.328546) (xy 181.031276 132.257974) (xy 181.147001 132.163001) + (xy 181.170804 132.133997) (xy 185.111003 128.193799) (xy 185.140001 128.170001) (xy 185.234974 128.054276) (xy 185.254326 128.018072) + (xy 185.75 128.018072) (xy 185.874482 128.005812) (xy 185.99418 127.969502) (xy 186.104494 127.910537) (xy 186.201185 127.831185) + (xy 186.280537 127.734494) (xy 186.339502 127.62418) (xy 186.375812 127.504482) (xy 186.388072 127.38) (xy 186.388072 125.38) + (xy 186.375812 125.255518) (xy 186.339502 125.13582) (xy 186.280537 125.025506) (xy 186.201185 124.928815) (xy 186.104494 124.849463) + (xy 185.99418 124.790498) (xy 185.874482 124.754188) (xy 185.75 124.741928) (xy 183.956887 124.741928) (xy 184.084609 124.550779) + (xy 184.204089 124.262327) (xy 184.265 123.956109) (xy 184.265 123.643891) (xy 184.204089 123.337673) (xy 184.084609 123.049221) + (xy 183.91115 122.789621) (xy 183.90153 122.780001) (xy 189.154677 122.780001) (xy 189.191999 122.783677) (xy 189.229321 122.780001) + (xy 189.229332 122.780001) (xy 189.340985 122.769004) (xy 189.484246 122.725547) (xy 189.616275 122.654975) (xy 189.732 122.560002) + (xy 189.755803 122.530998) (xy 191.590324 120.696478) (xy 191.693921 120.653567) (xy 191.830681 120.562187) (xy 191.946987 120.445881) + (xy 192.038367 120.309121) (xy 192.101311 120.15716) (xy 192.1334 119.99584) (xy 192.1334 119.83136) (xy 192.101311 119.67004) + (xy 192.045376 119.535) (xy 200.965531 119.535) (xy 201.009 119.539281) (xy 201.052469 119.535) (xy 201.052477 119.535) + (xy 201.18249 119.522195) (xy 201.349313 119.471589) (xy 201.503059 119.389411) (xy 201.637817 119.278817) (xy 201.665534 119.245044) + (xy 206.345051 114.565528) (xy 206.378817 114.537817) (xy 206.410672 114.499003) (xy 206.471195 114.425255) (xy 206.489411 114.403059) + (xy 206.571589 114.249313) (xy 206.622195 114.08249) (xy 206.635 113.952477) (xy 206.635 113.952467) (xy 206.639281 113.909001) + (xy 206.635 113.865535) (xy 206.635 105.76) (xy 207.38821 105.76) (xy 207.370506 105.769463) (xy 207.273815 105.848815) + (xy 207.194463 105.945506) (xy 207.135498 106.05582) (xy 207.099188 106.175518) (xy 207.086928 106.3) (xy 207.086928 107.6) + (xy 207.099188 107.724482) (xy 207.135498 107.84418) (xy 207.194463 107.954494) (xy 207.24 108.009982) (xy 207.24 108.252843) + (xy 207.197089 108.35644) (xy 207.165 108.51776) (xy 207.165 108.68224) (xy 207.197089 108.84356) (xy 207.24 108.947157) + (xy 207.240001 113.642073) (xy 207.215 113.76776) (xy 207.215 113.93224) (xy 207.247089 114.09356) (xy 207.290001 114.197159) + (xy 207.29 115.572215) (xy 207.286324 115.609538) (xy 207.29 115.64686) (xy 207.29 115.64687) (xy 207.300997 115.758523) + (xy 207.33379 115.866628) (xy 207.344454 115.901784) (xy 207.415026 116.033814) (xy 207.445696 116.071185) (xy 207.509999 116.149539) + (xy 207.539003 116.173342) (xy 208.901673 117.536013) (xy 208.925471 117.565011) (xy 209.041196 117.659984) (xy 209.173225 117.730556) + (xy 209.316486 117.774013) (xy 209.428139 117.78501) (xy 209.428147 117.78501) (xy 209.465472 117.788686) (xy 209.502797 117.78501) + (xy 210.21468 117.78501) (xy 210.252002 117.788686) (xy 210.289324 117.78501) (xy 210.289335 117.78501) (xy 210.400988 117.774013) + (xy 210.447183 117.76) (xy 220.962678 117.76) (xy 221 117.763676) (xy 221.037322 117.76) (xy 221.037333 117.76) + (xy 221.148986 117.749003) (xy 221.292247 117.705546) (xy 221.424276 117.634974) (xy 221.540001 117.540001) (xy 221.563804 117.510997) + (xy 223.261003 115.813799) (xy 223.290001 115.790001) (xy 223.384974 115.674276) (xy 223.455546 115.542247) (xy 223.499003 115.398986) + (xy 223.51 115.287333) (xy 223.51 115.287325) (xy 223.513676 115.25) (xy 223.51 115.212675) (xy 223.51 113.718072) + (xy 223.9 113.718072) (xy 224.024482 113.705812) (xy 224.14418 113.669502) (xy 224.254494 113.610537) (xy 224.351185 113.531185) + (xy 224.430537 113.434494) (xy 224.489502 113.32418) (xy 224.525812 113.204482) (xy 224.538072 113.08) (xy 224.538072 111.08) + (xy 224.525812 110.955518) (xy 224.489502 110.83582) (xy 224.430537 110.725506) (xy 224.351185 110.628815) (xy 224.254494 110.549463) + (xy 224.14418 110.490498) (xy 224.024482 110.454188) (xy 223.9 110.441928) (xy 222.106887 110.441928) (xy 222.234609 110.250779) + (xy 222.354089 109.962327) (xy 222.415 109.656109) (xy 222.415 109.343891) (xy 222.354089 109.037673) (xy 222.234609 108.749221) + (xy 222.06115 108.489621) (xy 221.840379 108.26885) (xy 221.580779 108.095391) (xy 221.292327 107.975911) (xy 220.986109 107.915) + (xy 220.673891 107.915) (xy 220.367673 107.975911) (xy 220.273303 108.015) (xy 220.10374 108.015) (xy 219.816842 108.072068) + (xy 219.546589 108.18401) (xy 219.303368 108.346525) (xy 219.096525 108.553368) (xy 218.93401 108.796589) (xy 218.822068 109.066842) + (xy 218.765 109.35374) (xy 218.765 109.64626) (xy 218.822068 109.933158) (xy 218.857988 110.019876) (xy 218.548698 110.147988) + (xy 218.326252 110.296622) (xy 218.331817 110.283186) (xy 218.435 109.764449) (xy 218.435 109.235551) (xy 218.331817 108.716814) + (xy 218.129417 108.228175) (xy 217.835576 107.788412) (xy 217.461588 107.414424) (xy 217.021825 107.120583) (xy 216.5762 106.936) + (xy 217.465123 106.936) (xy 217.5 106.939435) (xy 217.534877 106.936) (xy 217.581076 106.93145) (xy 217.639184 106.925727) + (xy 217.77302 106.885128) (xy 217.896363 106.8192) (xy 218.004475 106.730475) (xy 218.0932 106.622363) (xy 218.159128 106.49902) + (xy 218.199727 106.365184) (xy 218.21 106.260877) (xy 218.21 106.260876) (xy 218.213435 106.226) (xy 218.21 106.191123) + (xy 218.21 106.013072) (xy 218.95 106.013072) (xy 219.074482 106.000812) (xy 219.19418 105.964502) (xy 219.304494 105.905537) + (xy 219.401185 105.826185) (xy 219.480537 105.729494) (xy 219.539502 105.61918) (xy 219.562634 105.542923) (xy 219.624276 105.509974) + (xy 219.740001 105.415001) (xy 219.763804 105.385997) (xy 219.935998 105.213803) (xy 219.965001 105.190001) (xy 220.059974 105.074276) + (xy 220.130546 104.942247) (xy 220.174003 104.798986) (xy 220.185 104.687333) (xy 220.185 104.687324) (xy 220.188676 104.650001) + (xy 220.185 104.612678) (xy 220.185 103.472157) (xy 220.227911 103.36856) (xy 220.26 103.20724) (xy 220.26 103.04276) + (xy 220.227911 102.88144) (xy 220.164967 102.729479) (xy 220.073587 102.592719) (xy 219.957281 102.476413) (xy 219.820521 102.385033) + (xy 219.66856 102.322089) (xy 219.50724 102.29) (xy 219.490957 102.29) (xy 219.480537 102.270506) (xy 219.401185 102.173815) + (xy 219.304494 102.094463) (xy 219.19418 102.035498) (xy 219.074482 101.999188) (xy 218.95 101.986928) (xy 218.43575 101.99) + (xy 218.277002 102.148748) (xy 218.277002 101.99) (xy 218.21 101.99) (xy 218.21 101.760877) (xy 218.213435 101.726) + (xy 218.199727 101.586816) (xy 218.159128 101.45298) (xy 218.0932 101.329637) (xy 218.004475 101.221525) (xy 217.896363 101.1328) + (xy 217.77302 101.066872) (xy 217.639184 101.026273) (xy 217.534877 101.016) (xy 217.5 101.012565) (xy 217.465123 101.016) + (xy 214.034877 101.016) (xy 214 101.012565) (xy 213.965123 101.016) (xy 213.860816 101.026273) (xy 213.72698 101.066872) + (xy 213.603637 101.1328) (xy 213.495525 101.221525) (xy 213.4068 101.329637) (xy 213.340872 101.45298) (xy 213.300273 101.586816) + (xy 213.286565 101.726) (xy 213.290001 101.760887) (xy 213.290001 101.986928) (xy 212.55 101.986928) (xy 212.425518 101.999188) + (xy 212.30582 102.035498) (xy 212.195506 102.094463) (xy 212.098815 102.173815) (xy 212.019463 102.270506) (xy 211.960498 102.38082) + (xy 211.924188 102.500518) (xy 211.911928 102.625) (xy 211.911928 103.286241) (xy 211.854489 103.310033) (xy 211.717729 103.401413) + (xy 211.601423 103.517719) (xy 211.510043 103.654479) (xy 211.447099 103.80644) (xy 211.41501 103.96776) (xy 211.41501 103.99) + (xy 209.313072 103.99) (xy 209.313072 102.75) (xy 209.300812 102.625518) (xy 209.264502 102.50582) (xy 209.205537 102.395506) + (xy 209.126185 102.298815) (xy 209.029494 102.219463) (xy 208.91918 102.160498) (xy 208.799482 102.124188) (xy 208.675 102.111928) + (xy 208.109499 102.111928) (xy 208.318601 101.902826) (xy 208.645273 101.413928) (xy 208.870288 100.870692) (xy 208.985 100.293997) + (xy 208.985 99.706003) (xy 208.870288 99.129308) (xy 208.645273 98.586072) (xy 208.318601 98.097174) (xy 207.902826 97.681399) + (xy 207.413928 97.354727) (xy 206.870692 97.129712) (xy 206.293997 97.015) (xy 205.706003 97.015) (xy 205.129308 97.129712) + (xy 204.586072 97.354727) (xy 204.097174 97.681399) (xy 203.681399 98.097174) (xy 203.354727 98.586072) (xy 203.135 99.116542) + (xy 203.135 97.992178) (xy 206.453989 94.67319) (xy 206.515313 94.654587) (xy 206.669059 94.572409) (xy 206.803817 94.461815) + (xy 206.914411 94.327057) (xy 206.996589 94.173311) (xy 207.047195 94.006488) (xy 207.06 93.876475) (xy 207.06 93.744067) + (xy 207.064281 93.700601) (xy 207.06 93.657135) (xy 207.06 89.720302) (xy 207.101413 89.782281) (xy 207.217719 89.898587) + (xy 207.354479 89.989967) (xy 207.50644 90.052911) (xy 207.66776 90.085) (xy 207.83224 90.085) (xy 207.99356 90.052911) + (xy 208.145521 89.989967) (xy 208.282281 89.898587) (xy 208.398587 89.782281) (xy 208.489967 89.645521) (xy 208.552911 89.49356) + (xy 208.585 89.33224) (xy 208.585 89.226018) (xy 208.676185 89.151185) (xy 208.755537 89.054494) (xy 208.814502 88.94418) + (xy 208.850812 88.824482) (xy 208.863072 88.7) (xy 208.863072 87.4) (xy 208.850812 87.275518) (xy 208.814502 87.15582) + (xy 208.755537 87.045506) (xy 208.676185 86.948815) (xy 208.579494 86.869463) (xy 208.46918 86.810498) (xy 208.349482 86.774188) + (xy 208.225 86.761928) (xy 207.275 86.761928) (xy 207.150518 86.774188) (xy 207.06 86.801646) (xy 207.06 86.76) + (xy 211.994499 86.76) (xy 212.048815 86.826185) (xy 212.145506 86.905537) (xy 212.25582 86.964502) (xy 212.375518 87.000812) + (xy 212.5 87.013072) (xy 213.24 87.013072) (xy 213.24 87.254623) (xy 213.236565 87.2895) (xy 213.250273 87.428684) + (xy 213.290872 87.56252) (xy 213.3568 87.685863) (xy 213.445525 87.793975) (xy 213.553113 87.88227) (xy 213.553637 87.8827) + (xy 213.67698 87.948628) (xy 213.810816 87.989227) (xy 213.95 88.002935) (xy 213.984877 87.9995) (xy 214.720497 87.9995) + (xy 214.428175 88.120583) (xy 213.988412 88.414424) (xy 213.614424 88.788412) (xy 213.320583 89.228175) (xy 213.118183 89.716814) + (xy 213.015 90.235551) (xy 213.015 90.764449) (xy 213.118183 91.283186) (xy 213.123749 91.296623) (xy 212.901302 91.147989) + (xy 212.592012 91.019877) (xy 212.627932 90.933158) (xy 212.685 90.64626) (xy 212.685 90.35374) (xy 212.627932 90.066842) + (xy 212.51599 89.796589) (xy 212.353475 89.553368) (xy 212.146632 89.346525) (xy 211.903411 89.18401) (xy 211.633158 89.072068) + (xy 211.34626 89.015) (xy 211.176697 89.015) (xy 211.082327 88.975911) (xy 210.776109 88.915) (xy 210.463891 88.915) + (xy 210.157673 88.975911) (xy 209.869221 89.095391) (xy 209.609621 89.26885) (xy 209.38885 89.489621) (xy 209.215391 89.749221) + (xy 209.095911 90.037673) (xy 209.035 90.343891) (xy 209.035 90.656109) (xy 209.095911 90.962327) (xy 209.215391 91.250779) + (xy 209.38885 91.510379) (xy 209.609621 91.73115) (xy 209.869221 91.904609) (xy 210.035016 91.973283) (xy 209.997988 92.028699) + (xy 209.837047 92.417245) (xy 209.755 92.829722) (xy 209.755 93.25028) (xy 209.837047 93.662757) (xy 209.969252 93.981928) + (xy 208.85 93.981928) (xy 208.725518 93.994188) (xy 208.60582 94.030498) (xy 208.495506 94.089463) (xy 208.398815 94.168815) + (xy 208.319463 94.265506) (xy 208.260498 94.37582) (xy 208.224188 94.495518) (xy 208.211928 94.62) (xy 208.211928 96.62) + (xy 208.224188 96.744482) (xy 208.260498 96.86418) (xy 208.319463 96.974494) (xy 208.398815 97.071185) (xy 208.495506 97.150537) + (xy 208.60582 97.209502) (xy 208.725518 97.245812) (xy 208.85 97.258072) (xy 208.946764 97.258072) (xy 208.915 97.41776) + (xy 208.915 97.58224) (xy 208.947089 97.74356) (xy 209.010033 97.895521) (xy 209.101413 98.032281) (xy 209.217719 98.148587) + (xy 209.354479 98.239967) (xy 209.458077 98.282879) (xy 209.961202 98.786003) (xy 209.985 98.815002) (xy 210.013998 98.8388) + (xy 210.100724 98.909975) (xy 210.215353 98.971246) (xy 210.232754 98.980547) (xy 210.376015 99.024004) (xy 210.487668 99.035001) + (xy 210.487678 99.035001) (xy 210.525001 99.038677) (xy 210.562324 99.035001) (xy 220.964679 99.035001) (xy 221.002001 99.038677) + (xy 221.039323 99.035001) (xy 221.039334 99.035001) (xy 221.150987 99.024004) (xy 221.294248 98.980547) (xy 221.426277 98.909975) + (xy 221.542002 98.815002) (xy 221.565805 98.785998) (xy 223.211003 97.140801) (xy 223.240001 97.117003) (xy 223.334974 97.001278) + (xy 223.405546 96.869249) (xy 223.449003 96.725988) (xy 223.46 96.614335) (xy 223.46 96.614326) (xy 223.463676 96.577003) + (xy 223.46 96.53968) (xy 223.46 94.718072) (xy 223.85 94.718072) (xy 223.974482 94.705812) (xy 224.09418 94.669502) + (xy 224.204494 94.610537) (xy 224.301185 94.531185) (xy 224.380537 94.434494) (xy 224.439502 94.32418) (xy 224.475812 94.204482) + (xy 224.488072 94.08) (xy 224.488072 92.08) (xy 224.475812 91.955518) (xy 224.439502 91.83582) (xy 224.380537 91.725506) + (xy 224.301185 91.628815) (xy 224.204494 91.549463) (xy 224.09418 91.490498) (xy 223.974482 91.454188) (xy 223.85 91.441928) + (xy 222.056887 91.441928) (xy 222.184609 91.250779) (xy 222.304089 90.962327) (xy 222.365 90.656109) (xy 222.365 90.343891) + (xy 222.304089 90.037673) (xy 222.184609 89.749221) (xy 222.01115 89.489621) (xy 221.790379 89.26885) (xy 221.530779 89.095391) + (xy 221.242327 88.975911) (xy 220.936109 88.915) (xy 220.623891 88.915) (xy 220.317673 88.975911) (xy 220.223303 89.015) + (xy 220.05374 89.015) (xy 219.766842 89.072068) (xy 219.496589 89.18401) (xy 219.253368 89.346525) (xy 219.046525 89.553368) + (xy 218.88401 89.796589) (xy 218.772068 90.066842) (xy 218.715 90.35374) (xy 218.715 90.64626) (xy 218.772068 90.933158) + (xy 218.807988 91.019876) (xy 218.498698 91.147988) (xy 218.276252 91.296622) (xy 218.281817 91.283186) (xy 218.385 90.764449) + (xy 218.385 90.235551) (xy 218.281817 89.716814) (xy 218.079417 89.228175) (xy 217.785576 88.788412) (xy 217.411588 88.414424) + (xy 216.971825 88.120583) (xy 216.679503 87.9995) (xy 217.415123 87.9995) (xy 217.45 88.002935) (xy 217.484877 87.9995) + (xy 217.589184 87.989227) (xy 217.72302 87.948628) (xy 217.846363 87.8827) (xy 217.954475 87.793975) (xy 218.0432 87.685863) + (xy 218.109128 87.56252) (xy 218.149727 87.428684) (xy 218.163435 87.2895) (xy 218.16 87.254623) (xy 218.16 87.013072) + (xy 218.9 87.013072) (xy 219.024482 87.000812) (xy 219.14418 86.964502) (xy 219.254494 86.905537) (xy 219.351185 86.826185) + (xy 219.430537 86.729494) (xy 219.489502 86.61918) (xy 219.507022 86.561423) (xy 219.603276 86.509974) (xy 219.719001 86.415001) + (xy 219.742803 86.385998) (xy 220.261004 85.867798) (xy 220.290001 85.844001) (xy 220.326601 85.799404) (xy 220.384974 85.728277) + (xy 220.455546 85.596247) (xy 220.461156 85.577753) (xy 220.499003 85.452986) (xy 220.51 85.341333) (xy 220.51 85.341323) + (xy 220.513676 85.304) (xy 220.51 85.266677) (xy 220.51 85.097157) (xy 220.552911 84.99356) (xy 220.585 84.83224) + (xy 220.585 84.66776) (xy 220.552911 84.50644) (xy 220.489967 84.354479) (xy 220.398587 84.217719) (xy 220.282281 84.101413) + (xy 220.145521 84.010033) (xy 219.99356 83.947089) (xy 219.83224 83.915) (xy 219.66776 83.915) (xy 219.50644 83.947089) + (xy 219.383534 83.997998) (xy 219.376252 83.997998) (xy 219.535 83.83925) (xy 219.538072 83.625) (xy 219.525812 83.500518) + (xy 219.489502 83.38082) (xy 219.430537 83.270506) (xy 219.351185 83.173815) (xy 219.254494 83.094463) (xy 219.14418 83.035498) + (xy 219.024482 82.999188) (xy 218.9 82.986928) (xy 218.38575 82.99) (xy 218.227002 83.148748) (xy 218.227002 82.99) + (xy 218.16 82.99) (xy 218.16 82.824377) (xy 218.163435 82.7895) (xy 218.149727 82.650316) (xy 218.109128 82.51648) + (xy 218.0432 82.393137) (xy 217.954475 82.285025) (xy 217.846363 82.1963) (xy 217.72302 82.130372) (xy 217.589184 82.089773) + (xy 217.484877 82.0795) (xy 217.45 82.076065) (xy 217.415123 82.0795) (xy 213.984877 82.0795) (xy 213.95 82.076065) + (xy 213.915123 82.0795) (xy 213.810816 82.089773) (xy 213.67698 82.130372) (xy 213.553637 82.1963) (xy 213.445525 82.285025) + (xy 213.3568 82.393137) (xy 213.290872 82.51648) (xy 213.250273 82.650316) (xy 213.236565 82.7895) (xy 213.240001 82.824387) + (xy 213.240001 82.986928) (xy 212.5 82.986928) (xy 212.375518 82.999188) (xy 212.25582 83.035498) (xy 212.145506 83.094463) + (xy 212.048815 83.173815) (xy 211.969463 83.270506) (xy 211.910498 83.38082) (xy 211.874188 83.500518) (xy 211.861928 83.625) + (xy 211.861928 84.116271) (xy 211.787235 84.190963) (xy 211.75644 84.197089) (xy 211.604479 84.260033) (xy 211.467719 84.351413) + (xy 211.351413 84.467719) (xy 211.260033 84.604479) (xy 211.197089 84.75644) (xy 211.165 84.91776) (xy 211.165 84.99) + (xy 208.863072 84.99) (xy 208.863072 83.85) (xy 208.850812 83.725518) (xy 208.814502 83.60582) (xy 208.755537 83.495506) + (xy 208.676185 83.398815) (xy 208.579494 83.319463) (xy 208.46918 83.260498) (xy 208.349482 83.224188) (xy 208.225 83.211928) + (xy 207.275 83.211928) (xy 207.150518 83.224188) (xy 207.06 83.251646) (xy 207.06 75.42) (xy 208.211928 75.42) + (xy 208.211928 77.42) (xy 208.224188 77.544482) (xy 208.260498 77.66418) (xy 208.319463 77.774494) (xy 208.398815 77.871185) + (xy 208.495506 77.950537) (xy 208.60582 78.009502) (xy 208.725518 78.045812) (xy 208.85 78.058072) (xy 210.413271 78.058072) + (xy 211.41619 79.060992) (xy 211.439988 79.08999) (xy 211.468986 79.113788) (xy 211.555713 79.184963) (xy 211.687742 79.255535) + (xy 211.831003 79.298992) (xy 211.979989 79.313666) (xy 212.017322 79.309989) (xy 215.222386 79.309989) (xy 215.224089 79.318549) + (xy 215.287033 79.47051) (xy 215.378413 79.60727) (xy 215.494719 79.723576) (xy 215.631479 79.814956) (xy 215.78344 79.8779) + (xy 215.94476 79.909989) (xy 216.10924 79.909989) (xy 216.27056 79.8779) (xy 216.374157 79.834989) (xy 221.087689 79.834989) + (xy 221.125011 79.838665) (xy 221.162333 79.834989) (xy 221.162344 79.834989) (xy 221.273997 79.823992) (xy 221.417258 79.780535) + (xy 221.549287 79.709963) (xy 221.665012 79.61499) (xy 221.688814 79.585987) (xy 223.261008 78.013795) (xy 223.290001 77.990001) + (xy 223.313795 77.961008) (xy 223.313799 77.961004) (xy 223.384973 77.874277) (xy 223.385119 77.874004) (xy 223.455546 77.742247) + (xy 223.499003 77.598986) (xy 223.51 77.487333) (xy 223.51 77.487324) (xy 223.513676 77.450001) (xy 223.51 77.412678) + (xy 223.51 75.518072) (xy 223.85 75.518072) (xy 223.974482 75.505812) (xy 224.09418 75.469502) (xy 224.204494 75.410537) + (xy 224.301185 75.331185) (xy 224.380537 75.234494) (xy 224.439502 75.12418) (xy 224.475812 75.004482) (xy 224.488072 74.88) + (xy 224.488072 72.88) (xy 224.475812 72.755518) (xy 224.439502 72.63582) (xy 224.380537 72.525506) (xy 224.301185 72.428815) + (xy 224.204494 72.349463) (xy 224.09418 72.290498) (xy 223.974482 72.254188) (xy 223.85 72.241928) (xy 222.056887 72.241928) + (xy 222.184609 72.050779) (xy 222.304089 71.762327) (xy 222.365 71.456109) (xy 222.365 71.143891) (xy 222.304089 70.837673) + (xy 222.184609 70.549221) (xy 222.01115 70.289621) (xy 221.790379 70.06885) (xy 221.530779 69.895391) (xy 221.242327 69.775911) + (xy 220.936109 69.715) (xy 220.623891 69.715) (xy 220.317673 69.775911) (xy 220.223303 69.815) (xy 220.05374 69.815) + (xy 219.766842 69.872068) (xy 219.496589 69.98401) (xy 219.253368 70.146525) (xy 219.046525 70.353368) (xy 218.88401 70.596589) + (xy 218.772068 70.866842) (xy 218.715 71.15374) (xy 218.715 71.44626) (xy 218.772068 71.733158) (xy 218.807988 71.819876) + (xy 218.498698 71.947988) (xy 218.276252 72.096622) (xy 218.281817 72.083186) (xy 218.385 71.564449) (xy 218.385 71.035551) + (xy 218.281817 70.516814) (xy 218.079417 70.028175) (xy 217.785576 69.588412) (xy 217.411588 69.214424) (xy 216.971825 68.920583) + (xy 216.5262 68.736) (xy 217.415123 68.736) (xy 217.45 68.739435) (xy 217.484877 68.736) (xy 217.532731 68.731287) + (xy 217.589184 68.725727) (xy 217.72302 68.685128) (xy 217.846363 68.6192) (xy 217.954475 68.530475) (xy 218.0432 68.422363) + (xy 218.109128 68.29902) (xy 218.149727 68.165184) (xy 218.156716 68.094224) (xy 218.163435 68.026) (xy 218.16 67.991123) + (xy 218.16 67.813072) (xy 218.9 67.813072) (xy 219.024482 67.800812) (xy 219.14418 67.764502) (xy 219.254494 67.705537) + (xy 219.351185 67.626185) (xy 219.430537 67.529494) (xy 219.489502 67.41918) (xy 219.525812 67.299482) (xy 219.527021 67.287204) + (xy 219.615001 67.215001) (xy 219.638804 67.185997) (xy 220.030498 66.794303) (xy 220.059501 66.770501) (xy 220.13008 66.6845) + (xy 220.154474 66.654777) (xy 220.225046 66.522747) (xy 220.233305 66.495521) (xy 220.268503 66.379486) (xy 220.2795 66.267833) + (xy 220.2795 66.267823) (xy 220.283176 66.2305) (xy 220.279777 66.195988) (xy 220.322411 66.09306) (xy 220.3545 65.93174) + (xy 220.3545 65.76726) (xy 220.322411 65.60594) (xy 220.259467 65.453979) (xy 220.168087 65.317219) (xy 220.051781 65.200913) + (xy 219.915021 65.109533) (xy 219.76306 65.046589) (xy 219.60174 65.0145) (xy 219.43726 65.0145) (xy 219.27594 65.046589) + (xy 219.262877 65.052) (xy 218.227 65.052) (xy 218.227 65.072) (xy 218.16 65.072) (xy 218.16 64.778) + (xy 218.227 64.778) (xy 218.227 64.798) (xy 219.37625 64.798) (xy 219.535 64.63925) (xy 219.538072 64.425) + (xy 219.525812 64.300518) (xy 219.489502 64.18082) (xy 219.430537 64.070506) (xy 219.351185 63.973815) (xy 219.254494 63.894463) + (xy 219.14418 63.835498) (xy 219.024482 63.799188) (xy 218.9 63.786928) (xy 218.38575 63.79) (xy 218.227002 63.948748) + (xy 218.227002 63.79) (xy 218.16 63.79) (xy 218.16 63.560877) (xy 218.163435 63.526) (xy 218.149727 63.386816) + (xy 218.109128 63.25298) (xy 218.0432 63.129637) (xy 217.954475 63.021525) (xy 217.846363 62.9328) (xy 217.72302 62.866872) + (xy 217.589184 62.826273) (xy 217.484877 62.816) (xy 217.45 62.812565) (xy 217.415123 62.816) (xy 213.984877 62.816) + (xy 213.95 62.812565) (xy 213.915123 62.816) (xy 213.810816 62.826273) (xy 213.67698 62.866872) (xy 213.553637 62.9328) + (xy 213.445525 63.021525) (xy 213.3568 63.129637) (xy 213.290872 63.25298) (xy 213.250273 63.386816) (xy 213.236565 63.526) + (xy 213.240001 63.560887) (xy 213.240001 63.786928) (xy 212.5 63.786928) (xy 212.375518 63.799188) (xy 212.25582 63.835498) + (xy 212.145506 63.894463) (xy 212.048815 63.973815) (xy 211.969463 64.070506) (xy 211.918954 64.165) (xy 211.762325 64.165) + (xy 211.725 64.161324) (xy 211.687675 64.165) (xy 211.687667 64.165) (xy 211.576014 64.175997) (xy 211.432753 64.219454) + (xy 211.300724 64.290026) (xy 211.184999 64.384999) (xy 211.161201 64.413998) (xy 210.440404 65.134795) (xy 210.411401 65.158597) + (xy 210.363269 65.217247) (xy 210.316428 65.274322) (xy 210.264952 65.370626) (xy 210.245856 65.406352) (xy 210.202399 65.549613) + (xy 210.191402 65.661266) (xy 210.191402 65.661276) (xy 210.187726 65.698598) (xy 210.191402 65.735921) (xy 210.191403 66.602841) + (xy 210.148491 66.70644) (xy 210.116402 66.86776) (xy 210.116402 67.03224) (xy 210.148491 67.19356) (xy 210.211435 67.345521) + (xy 210.302815 67.482281) (xy 210.419121 67.598587) (xy 210.555881 67.689967) (xy 210.65948 67.732879) (xy 212.240001 69.313401) + (xy 212.240001 70.239894) (xy 212.146632 70.146525) (xy 211.903411 69.98401) (xy 211.633158 69.872068) (xy 211.34626 69.815) + (xy 211.176697 69.815) (xy 211.082327 69.775911) (xy 210.776109 69.715) (xy 210.463891 69.715) (xy 210.157673 69.775911) + (xy 209.869221 69.895391) (xy 209.609621 70.06885) (xy 209.38885 70.289621) (xy 209.215391 70.549221) (xy 209.095911 70.837673) + (xy 209.035 71.143891) (xy 209.035 71.456109) (xy 209.095911 71.762327) (xy 209.215391 72.050779) (xy 209.38885 72.310379) + (xy 209.609621 72.53115) (xy 209.869221 72.704609) (xy 210.035016 72.773283) (xy 209.997988 72.828699) (xy 209.837047 73.217245) + (xy 209.755 73.629722) (xy 209.755 74.05028) (xy 209.837047 74.462757) (xy 209.969252 74.781928) (xy 208.85 74.781928) + (xy 208.725518 74.794188) (xy 208.60582 74.830498) (xy 208.495506 74.889463) (xy 208.398815 74.968815) (xy 208.319463 75.065506) + (xy 208.260498 75.17582) (xy 208.224188 75.295518) (xy 208.211928 75.42) (xy 207.06 75.42) (xy 207.06 70.970302) + (xy 207.101413 71.032281) (xy 207.217719 71.148587) (xy 207.354479 71.239967) (xy 207.50644 71.302911) (xy 207.66776 71.335) + (xy 207.83224 71.335) (xy 207.99356 71.302911) (xy 208.145521 71.239967) (xy 208.282281 71.148587) (xy 208.398587 71.032281) + (xy 208.489967 70.895521) (xy 208.552911 70.74356) (xy 208.585 70.58224) (xy 208.585 70.41776) (xy 208.552911 70.25644) + (xy 208.548945 70.246866) (xy 208.579494 70.230537) (xy 208.676185 70.151185) (xy 208.755537 70.054494) (xy 208.814502 69.94418) + (xy 208.850812 69.824482) (xy 208.863072 69.7) (xy 208.863072 68.4) (xy 208.850812 68.275518) (xy 208.814502 68.15582) + (xy 208.755537 68.045506) (xy 208.676185 67.948815) (xy 208.579494 67.869463) (xy 208.46918 67.810498) (xy 208.349482 67.774188) + (xy 208.225 67.761928) (xy 207.275 67.761928) (xy 207.150518 67.774188) (xy 207.06 67.801646) (xy 207.06 66.748354) + (xy 207.150518 66.775812) (xy 207.275 66.788072) (xy 208.225 66.788072) (xy 208.349482 66.775812) (xy 208.46918 66.739502) + (xy 208.579494 66.680537) (xy 208.676185 66.601185) (xy 208.755537 66.504494) (xy 208.814502 66.39418) (xy 208.850812 66.274482) + (xy 208.863072 66.15) (xy 208.863072 64.85) (xy 208.850812 64.725518) (xy 208.814502 64.60582) (xy 208.755537 64.495506) + (xy 208.676185 64.398815) (xy 208.579494 64.319463) (xy 208.46918 64.260498) (xy 208.349482 64.224188) (xy 208.225 64.211928) + (xy 207.275 64.211928) (xy 207.246148 64.21477) (xy 207.413928 64.145273) (xy 207.902826 63.818601) (xy 208.318601 63.402826) + (xy 208.645273 62.913928) (xy 208.870288 62.370692) (xy 208.985 61.793997) (xy 208.985 61.206003) (xy 208.870288 60.629308) + (xy 208.645273 60.086072) (xy 208.318601 59.597174) (xy 207.902826 59.181399) (xy 207.413928 58.854727) (xy 206.870692 58.629712) + (xy 206.293997 58.515) (xy 205.706003 58.515) (xy 205.129308 58.629712) (xy 204.586072 58.854727) (xy 204.097174 59.181399) + (xy 203.705511 59.573062) (xy 203.705511 59.296067) (xy 206.59505 56.406529) (xy 206.628817 56.378817) (xy 206.663793 56.3362) + (xy 206.73941 56.24406) (xy 206.739411 56.244059) (xy 206.821589 56.090313) (xy 206.872195 55.92349) (xy 206.885 55.793477) + (xy 206.885 55.793467) (xy 206.889281 55.750001) (xy 206.885 55.706535) (xy 206.885 52.951398) (xy 206.915 52.976018) + (xy 206.915 53.08224) (xy 206.947089 53.24356) (xy 207.010033 53.395521) (xy 207.101413 53.532281) (xy 207.217719 53.648587) + (xy 207.354479 53.739967) (xy 207.50644 53.802911) (xy 207.66776 53.835) (xy 207.83224 53.835) (xy 207.99356 53.802911) + (xy 208.145521 53.739967) (xy 208.282281 53.648587) (xy 208.398587 53.532281) (xy 208.489967 53.395521) (xy 208.49 53.395441) + (xy 208.49 56.079556) (xy 208.419463 56.165506) (xy 208.360498 56.27582) (xy 208.324188 56.395518) (xy 208.311928 56.52) + (xy 208.311928 58.52) (xy 208.324188 58.644482) (xy 208.360498 58.76418) (xy 208.419463 58.874494) (xy 208.498815 58.971185) + (xy 208.595506 59.050537) (xy 208.70582 59.109502) (xy 208.825518 59.145812) (xy 208.95 59.158072) (xy 210.56327 59.158072) + (xy 211.682401 60.277203) (xy 211.706199 60.306201) (xy 211.821924 60.401174) (xy 211.953953 60.471746) (xy 212.097214 60.515203) + (xy 212.208867 60.5262) (xy 212.208875 60.5262) (xy 212.2462 60.529876) (xy 212.283525 60.5262) (xy 213.850784 60.5262) + (xy 213.852489 60.53477) (xy 213.915433 60.686731) (xy 214.006813 60.823491) (xy 214.123119 60.939797) (xy 214.259879 61.031177) + (xy 214.41184 61.094121) (xy 214.57316 61.12621) (xy 214.73764 61.12621) (xy 214.89896 61.094121) (xy 215.002557 61.05121) + (xy 220.671468 61.05121) (xy 220.70879 61.054886) (xy 220.746112 61.05121) (xy 220.746123 61.05121) (xy 220.857776 61.040213) + (xy 221.001037 60.996756) (xy 221.133066 60.926184) (xy 221.248791 60.831211) (xy 221.272594 60.802207) (xy 223.211003 58.863799) + (xy 223.240001 58.840001) (xy 223.334974 58.724276) (xy 223.405546 58.592247) (xy 223.449003 58.448986) (xy 223.46 58.337333) + (xy 223.46 58.337324) (xy 223.463676 58.300001) (xy 223.46 58.262678) (xy 223.46 56.618072) (xy 223.95 56.618072) + (xy 224.074482 56.605812) (xy 224.19418 56.569502) (xy 224.304494 56.510537) (xy 224.401185 56.431185) (xy 224.480537 56.334494) + (xy 224.539502 56.22418) (xy 224.575812 56.104482) (xy 224.588072 55.98) (xy 224.588072 53.98) (xy 224.575812 53.855518) + (xy 224.539502 53.73582) (xy 224.480537 53.625506) (xy 224.401185 53.528815) (xy 224.304494 53.449463) (xy 224.19418 53.390498) + (xy 224.074482 53.354188) (xy 223.95 53.341928) (xy 222.156887 53.341928) (xy 222.284609 53.150779) (xy 222.404089 52.862327) + (xy 222.465 52.556109) (xy 222.465 52.243891) (xy 222.404089 51.937673) (xy 222.284609 51.649221) (xy 222.11115 51.389621) + (xy 221.890379 51.16885) (xy 221.630779 50.995391) (xy 221.342327 50.875911) (xy 221.036109 50.815) (xy 220.723891 50.815) + (xy 220.417673 50.875911) (xy 220.323303 50.915) (xy 220.15374 50.915) (xy 219.866842 50.972068) (xy 219.596589 51.08401) + (xy 219.353368 51.246525) (xy 219.146525 51.453368) (xy 218.98401 51.696589) (xy 218.872068 51.966842) (xy 218.815 52.25374) + (xy 218.815 52.54626) (xy 218.872068 52.833158) (xy 218.907988 52.919876) (xy 218.598698 53.047988) (xy 218.376252 53.196622) + (xy 218.381817 53.183186) (xy 218.485 52.664449) (xy 218.485 52.135551) (xy 218.381817 51.616814) (xy 218.179417 51.128175) + (xy 217.885576 50.688412) (xy 217.511588 50.314424) (xy 217.071825 50.020583) (xy 216.687522 49.8614) (xy 217.415123 49.8614) + (xy 217.45 49.864835) (xy 217.484877 49.8614) (xy 217.589184 49.851127) (xy 217.72302 49.810528) (xy 217.846363 49.7446) + (xy 217.954475 49.655875) (xy 218.0432 49.547763) (xy 218.109128 49.42442) (xy 218.149727 49.290584) (xy 218.163435 49.1514) + (xy 218.16 49.116523) (xy 218.16 48.913072) (xy 219 48.913072) (xy 219.124482 48.900812) (xy 219.24418 48.864502) + (xy 219.354494 48.805537) (xy 219.451185 48.726185) (xy 219.530537 48.629494) (xy 219.589502 48.51918) (xy 219.625812 48.399482) + (xy 219.638072 48.275) (xy 219.638072 47.804003) (xy 219.64356 47.802911) (xy 219.795521 47.739967) (xy 219.932281 47.648587) + (xy 220.048587 47.532281) (xy 220.139967 47.395521) (xy 220.202911 47.24356) (xy 220.235 47.08224) (xy 220.235 46.91776) + (xy 220.202911 46.75644) (xy 220.139967 46.604479) (xy 220.048587 46.467719) (xy 219.932281 46.351413) (xy 219.795521 46.260033) + (xy 219.64356 46.197089) (xy 219.490991 46.166741) (xy 219.47625 46.152) (xy 218.327 46.152) (xy 218.327 46.172) + (xy 218.16 46.172) (xy 218.16 45.878) (xy 218.327 45.878) (xy 218.327 45.898) (xy 219.47625 45.898) + (xy 219.635 45.73925) (xy 219.638072 45.525) (xy 219.625812 45.400518) (xy 219.589502 45.28082) (xy 219.530537 45.170506) + (xy 219.451185 45.073815) (xy 219.354494 44.994463) (xy 219.24418 44.935498) (xy 219.124482 44.899188) (xy 219.07402 44.894218) + (xy 219.139967 44.795521) (xy 219.202911 44.64356) (xy 219.235 44.48224) (xy 219.235 44.31776) (xy 219.202911 44.15644) + (xy 219.139967 44.004479) (xy 219.048587 43.867719) (xy 218.932281 43.751413) (xy 218.795521 43.660033) (xy 218.683506 43.613635) + (xy 218.624277 43.565027) (xy 218.492248 43.494455) (xy 218.348987 43.450998) (xy 218.237334 43.440001) (xy 218.237323 43.440001) + (xy 218.200001 43.436325) (xy 218.162679 43.440001) (xy 211.837324 43.440001) (xy 211.799999 43.436325) (xy 211.762674 43.440001) + (xy 211.762666 43.440001) (xy 211.651013 43.450998) (xy 211.507752 43.494455) (xy 211.375723 43.565027) (xy 211.259998 43.66) + (xy 211.236195 43.689004) (xy 210.978803 43.946396) (xy 210.978797 43.946401) (xy 210.01 44.915199) (xy 210.01 44.873122) + (xy 210.013676 44.835799) (xy 210.01 44.798476) (xy 210.01 44.798467) (xy 209.999003 44.686814) (xy 209.955546 44.543553) + (xy 209.884974 44.411524) (xy 209.864029 44.386002) (xy 209.813799 44.324796) (xy 209.813795 44.324792) (xy 209.790001 44.295799) + (xy 209.761008 44.272005) (xy 208.564403 43.075402) (xy 208.540601 43.046399) (xy 208.424876 42.951426) (xy 208.292847 42.880854) + (xy 208.149586 42.837397) (xy 208.037933 42.8264) (xy 208.037922 42.8264) (xy 208.0006 42.822724) (xy 207.963278 42.8264) + (xy 194.551202 42.8264) (xy 190.503369 38.778568) + ) + ) + (filled_polygon + (pts + (xy 103.6686 128.39664) (xy 103.700689 128.55796) (xy 103.763633 128.709921) (xy 103.855013 128.846681) (xy 103.971319 128.962987) + (xy 104.108079 129.054367) (xy 104.26004 129.117311) (xy 104.42136 129.1494) (xy 104.58584 129.1494) (xy 104.74716 129.117311) + (xy 104.850757 129.0744) (xy 108.850798 129.0744) (xy 104.600292 133.324907) (xy 104.600253 133.324933) (xy 104.568436 133.35675) + (xy 104.539506 133.380492) (xy 104.515763 133.409423) (xy 104.483947 133.441239) (xy 104.45895 133.47865) (xy 104.455361 133.483023) + (xy 103.698385 134.24) (xy 103.514803 134.24) (xy 103.261276 133.986474) (xy 103.320649 133.890993) (xy 103.329993 133.866166) + (xy 103.356167 133.870487) (xy 103.481184 133.866395) (xy 103.603001 133.837991) (xy 103.716935 133.786368) (xy 103.900945 133.676582) + (xy 103.959052 133.459726) (xy 103.384427 132.464446) (xy 103.367106 132.474446) (xy 103.342981 132.432661) (xy 103.597593 132.285661) + (xy 103.621718 132.327446) (xy 103.604397 132.337446) (xy 104.179022 133.332726) (xy 104.395879 133.390832) (xy 104.582961 133.286368) + (xy 104.684635 133.213509) (xy 104.770142 133.122215) (xy 104.836194 133.015993) (xy 104.880255 132.898926) (xy 104.90063 132.775514) + (xy 104.896538 132.650496) (xy 104.868135 132.52868) (xy 104.816511 132.414745) (xy 104.556726 131.970928) (xy 104.339872 131.912822) + (xy 104.477352 131.833448) (xy 104.453226 131.791661) (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) + (xy 104.651604 131.677128) (xy 104.7368 131.616078) (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) + (xy 104.978308 131.126349) (xy 104.973731 130.986567) (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.898716 130.754892) + (xy 104.884253 130.722971) (xy 104.863839 130.694483) (xy 103.527189 128.379338) (xy 103.6686 128.379338) + ) + ) + (filled_polygon + (pts + (xy 193.6726 44.097402) (xy 193.696399 44.126401) (xy 193.812124 44.221374) (xy 193.944153 44.291946) (xy 194.087414 44.335403) + (xy 194.199067 44.3464) (xy 194.199076 44.3464) (xy 194.236399 44.350076) (xy 194.273722 44.3464) (xy 194.307217 44.3464) + (xy 194.290872 44.37698) (xy 194.250273 44.510816) (xy 194.236565 44.65) (xy 194.240001 44.684887) (xy 194.240001 44.886928) + (xy 193.887064 44.886928) (xy 193.901781 44.737501) (xy 193.884694 44.564011) (xy 193.834088 44.397187) (xy 193.75191 44.243442) + (xy 193.641317 44.108683) (xy 193.506558 43.99809) (xy 193.352813 43.915912) (xy 193.185989 43.865306) (xy 193.012499 43.848219) + (xy 192.839009 43.865306) (xy 192.672186 43.915912) (xy 192.51844 43.99809) (xy 192.417453 44.080968) (xy 191.174951 45.323471) + (xy 191.141184 45.351183) (xy 191.113471 45.384951) (xy 191.113468 45.384954) (xy 191.03059 45.485941) (xy 190.948412 45.639687) + (xy 190.897805 45.80651) (xy 190.880719 45.98) (xy 190.885001 46.023478) (xy 190.885 47.13703) (xy 190.880719 47.1805) + (xy 190.885 47.223969) (xy 190.885 47.223976) (xy 190.892782 47.302985) (xy 190.897805 47.35399) (xy 190.907204 47.384974) + (xy 190.948411 47.520812) (xy 191.030589 47.674558) (xy 191.141183 47.809317) (xy 191.174956 47.837034) (xy 191.74847 48.410549) + (xy 191.776183 48.444317) (xy 191.809951 48.47203) (xy 191.809953 48.472032) (xy 191.910941 48.554911) (xy 192.064686 48.637089) + (xy 192.202903 48.679017) (xy 192.23151 48.687695) (xy 192.361523 48.7005) (xy 192.361531 48.7005) (xy 192.405 48.704781) + (xy 192.448469 48.7005) (xy 193.027736 48.7005) (xy 193.048815 48.726185) (xy 193.145506 48.805537) (xy 193.25582 48.864502) + (xy 193.375518 48.900812) (xy 193.5 48.913072) (xy 194.24 48.913072) (xy 194.24 49.115123) (xy 194.236565 49.15) + (xy 194.250273 49.289184) (xy 194.290872 49.42302) (xy 194.3568 49.546363) (xy 194.445525 49.654475) (xy 194.528097 49.72224) + (xy 194.553637 49.7432) (xy 194.67698 49.809128) (xy 194.810816 49.849727) (xy 194.95 49.863435) (xy 194.984877 49.86) + (xy 195.815858 49.86) (xy 195.428175 50.020583) (xy 194.988412 50.314424) (xy 194.614424 50.688412) (xy 194.320583 51.128175) + (xy 194.118183 51.616814) (xy 194.015 52.135551) (xy 194.015 52.664449) (xy 194.118183 53.183186) (xy 194.123749 53.196623) + (xy 193.901302 53.047989) (xy 193.592012 52.919877) (xy 193.627932 52.833158) (xy 193.685 52.54626) (xy 193.685 52.25374) + (xy 193.627932 51.966842) (xy 193.51599 51.696589) (xy 193.353475 51.453368) (xy 193.146632 51.246525) (xy 192.903411 51.08401) + (xy 192.633158 50.972068) (xy 192.34626 50.915) (xy 192.176697 50.915) (xy 192.082327 50.875911) (xy 191.776109 50.815) + (xy 191.463891 50.815) (xy 191.157673 50.875911) (xy 190.869221 50.995391) (xy 190.609621 51.16885) (xy 190.38885 51.389621) + (xy 190.215391 51.649221) (xy 190.095911 51.937673) (xy 190.035 52.243891) (xy 190.035 47.812322) (xy 190.038676 47.774999) + (xy 190.035 47.737676) (xy 190.035 47.737667) (xy 190.024003 47.626014) (xy 189.980546 47.482753) (xy 189.909974 47.350724) + (xy 189.815001 47.234999) (xy 189.786003 47.211201) (xy 188.782879 46.208077) (xy 188.739967 46.104479) (xy 188.648587 45.967719) + (xy 188.532281 45.851413) (xy 188.395521 45.760033) (xy 188.24356 45.697089) (xy 188.08224 45.665) (xy 187.91776 45.665) + (xy 187.75644 45.697089) (xy 187.604479 45.760033) (xy 187.467719 45.851413) (xy 187.351413 45.967719) (xy 187.260033 46.104479) + (xy 187.197089 46.25644) (xy 187.165 46.41776) (xy 187.165 46.58224) (xy 187.197089 46.74356) (xy 187.260033 46.895521) + (xy 187.351413 47.032281) (xy 187.467719 47.148587) (xy 187.5251 47.186928) (xy 187.525 47.186928) (xy 187.400518 47.199188) + (xy 187.28082 47.235498) (xy 187.170506 47.294463) (xy 187.073815 47.373815) (xy 186.994463 47.470506) (xy 186.935498 47.58082) + (xy 186.899188 47.700518) (xy 186.886928 47.825) (xy 186.886928 49.125) (xy 186.899188 49.249482) (xy 186.935498 49.36918) + (xy 186.994463 49.479494) (xy 187.073815 49.576185) (xy 187.167863 49.653368) (xy 187.165 49.66776) (xy 187.165 49.83224) + (xy 187.197089 49.99356) (xy 187.260033 50.145521) (xy 187.329844 50.25) (xy 187.260033 50.354479) (xy 187.197089 50.50644) + (xy 187.165 50.66776) (xy 187.165 50.83224) (xy 187.167863 50.846632) (xy 187.073815 50.923815) (xy 186.994463 51.020506) + (xy 186.935498 51.13082) (xy 186.899188 51.250518) (xy 186.886928 51.375) (xy 186.886928 52.675) (xy 186.899188 52.799482) + (xy 186.935498 52.91918) (xy 186.994463 53.029494) (xy 187.073815 53.126185) (xy 187.170506 53.205537) (xy 187.28082 53.264502) + (xy 187.400518 53.300812) (xy 187.525 53.313072) (xy 188.475 53.313072) (xy 188.515 53.309132) (xy 188.515 56.902843) + (xy 188.472089 57.00644) (xy 188.44 57.16776) (xy 188.44 57.33224) (xy 188.472089 57.49356) (xy 188.535033 57.645521) + (xy 188.626413 57.782281) (xy 188.742719 57.898587) (xy 188.879479 57.989967) (xy 189.03144 58.052911) (xy 189.19276 58.085) + (xy 189.211928 58.085) (xy 189.211928 58.52) (xy 189.224188 58.644482) (xy 189.260498 58.76418) (xy 189.319463 58.874494) + (xy 189.398815 58.971185) (xy 189.495506 59.050537) (xy 189.60582 59.109502) (xy 189.725518 59.145812) (xy 189.85 59.158072) + (xy 192.15 59.158072) (xy 192.274482 59.145812) (xy 192.39418 59.109502) (xy 192.504494 59.050537) (xy 192.601185 58.971185) + (xy 192.615002 58.954348) (xy 192.799017 59.138363) (xy 193.148698 59.372012) (xy 193.433546 59.49) (xy 193.414465 59.49) + (xy 193.370999 59.485719) (xy 193.327533 59.49) (xy 193.327523 59.49) (xy 193.19751 59.502805) (xy 193.030687 59.553411) + (xy 192.876941 59.635589) (xy 192.86837 59.642623) (xy 192.775953 59.718468) (xy 192.775951 59.71847) (xy 192.742183 59.746183) + (xy 192.71447 59.779951) (xy 191.936956 60.557466) (xy 191.903183 60.585183) (xy 191.792589 60.719942) (xy 191.710411 60.873688) + (xy 191.679458 60.975724) (xy 191.67674 60.984684) (xy 191.598587 60.867719) (xy 191.482281 60.751413) (xy 191.345521 60.660033) + (xy 191.19356 60.597089) (xy 191.03224 60.565) (xy 190.86776 60.565) (xy 190.70644 60.597089) (xy 190.554479 60.660033) + (xy 190.417719 60.751413) (xy 190.301413 60.867719) (xy 190.210033 61.004479) (xy 190.147089 61.15644) (xy 190.115 61.31776) + (xy 190.115 61.48224) (xy 190.147089 61.64356) (xy 190.210033 61.795521) (xy 190.301413 61.932281) (xy 190.417719 62.048587) + (xy 190.554479 62.139967) (xy 190.658077 62.182879) (xy 191.286362 62.811164) (xy 191.23144 62.822089) (xy 191.127843 62.865) + (xy 189.623613 62.865) (xy 189.580372 62.847089) (xy 189.419052 62.815) (xy 189.254572 62.815) (xy 189.093252 62.847089) + (xy 188.941291 62.910033) (xy 188.804531 63.001413) (xy 188.688225 63.117719) (xy 188.596845 63.254479) (xy 188.533901 63.40644) + (xy 188.501812 63.56776) (xy 188.501812 63.711928) (xy 187.775 63.711928) (xy 187.650518 63.724188) (xy 187.53082 63.760498) + (xy 187.420506 63.819463) (xy 187.323815 63.898815) (xy 187.244463 63.995506) (xy 187.185498 64.10582) (xy 187.149188 64.225518) + (xy 187.136928 64.35) (xy 187.136928 65.65) (xy 187.149188 65.774482) (xy 187.185498 65.89418) (xy 187.244463 66.004494) + (xy 187.323815 66.101185) (xy 187.420506 66.180537) (xy 187.53082 66.239502) (xy 187.650518 66.275812) (xy 187.775 66.288072) + (xy 188.725 66.288072) (xy 188.74 66.286595) (xy 188.74 66.823162) (xy 188.645521 66.760033) (xy 188.49356 66.697089) + (xy 188.33224 66.665) (xy 188.16776 66.665) (xy 188.00644 66.697089) (xy 187.854479 66.760033) (xy 187.717719 66.851413) + (xy 187.601413 66.967719) (xy 187.510033 67.104479) (xy 187.447089 67.25644) (xy 187.425095 67.36701) (xy 187.420506 67.369463) + (xy 187.323815 67.448815) (xy 187.244463 67.545506) (xy 187.185498 67.65582) (xy 187.149188 67.775518) (xy 187.136928 67.9) + (xy 187.136928 69.2) (xy 187.149188 69.324482) (xy 187.185498 69.44418) (xy 187.244463 69.554494) (xy 187.323815 69.651185) + (xy 187.420506 69.730537) (xy 187.53082 69.789502) (xy 187.650518 69.825812) (xy 187.775 69.838072) (xy 188.725 69.838072) + (xy 188.849482 69.825812) (xy 188.96918 69.789502) (xy 189.079494 69.730537) (xy 189.176185 69.651185) (xy 189.255537 69.554494) + (xy 189.29 69.490018) (xy 189.29 74.182678) (xy 189.286324 74.22) (xy 189.29 74.257322) (xy 189.29 74.257332) + (xy 189.300997 74.368985) (xy 189.327486 74.456308) (xy 189.344454 74.512246) (xy 189.415026 74.644276) (xy 189.438204 74.672518) + (xy 189.509999 74.760001) (xy 189.539002 74.783804) (xy 189.592706 74.837507) (xy 189.495506 74.889463) (xy 189.398815 74.968815) + (xy 189.319463 75.065506) (xy 189.260498 75.17582) (xy 189.224188 75.295518) (xy 189.211928 75.42) (xy 189.211928 77.42) + (xy 189.224188 77.544482) (xy 189.260498 77.66418) (xy 189.319463 77.774494) (xy 189.398815 77.871185) (xy 189.495506 77.950537) + (xy 189.60582 78.009502) (xy 189.725518 78.045812) (xy 189.85 78.058072) (xy 190.030084 78.058072) (xy 190.047089 78.14356) + (xy 190.110033 78.295521) (xy 190.201413 78.432281) (xy 190.317719 78.548587) (xy 190.454479 78.639967) (xy 190.60644 78.702911) + (xy 190.76776 78.735) (xy 190.93224 78.735) (xy 191.09356 78.702911) (xy 191.245521 78.639967) (xy 191.382281 78.548587) + (xy 191.498587 78.432281) (xy 191.589967 78.295521) (xy 191.652911 78.14356) (xy 191.669916 78.058072) (xy 192.15 78.058072) + (xy 192.274482 78.045812) (xy 192.39418 78.009502) (xy 192.504494 77.950537) (xy 192.601185 77.871185) (xy 192.615002 77.854348) + (xy 192.799017 78.038363) (xy 193.148698 78.272012) (xy 193.537244 78.432953) (xy 193.833347 78.491852) (xy 193.308078 79.017121) + (xy 193.204479 79.060033) (xy 193.067719 79.151413) (xy 192.951413 79.267719) (xy 192.860033 79.404479) (xy 192.797089 79.55644) + (xy 192.765 79.71776) (xy 192.765 79.88224) (xy 192.797089 80.04356) (xy 192.860033 80.195521) (xy 192.951413 80.332281) + (xy 193.067719 80.448587) (xy 193.204479 80.539967) (xy 193.35644 80.602911) (xy 193.51776 80.635) (xy 193.68224 80.635) + (xy 193.84356 80.602911) (xy 193.995521 80.539967) (xy 194.132281 80.448587) (xy 194.248587 80.332281) (xy 194.339967 80.195521) + (xy 194.382879 80.091922) (xy 196.496005 77.978797) (xy 196.525002 77.955) (xy 196.619975 77.839275) (xy 196.690547 77.707246) + (xy 196.734004 77.563985) (xy 196.745001 77.452332) (xy 196.745001 77.452324) (xy 196.748677 77.414999) (xy 196.745001 77.377674) + (xy 196.745001 75.978798) (xy 197.342958 75.380841) (xy 197.187047 75.757244) (xy 197.105 76.169721) (xy 197.105 76.590279) + (xy 197.187047 77.002756) (xy 197.347988 77.391302) (xy 197.581637 77.740983) (xy 197.879017 78.038363) (xy 198.228698 78.272012) + (xy 198.617244 78.432953) (xy 199.029721 78.515) (xy 199.450279 78.515) (xy 199.862756 78.432953) (xy 200.251302 78.272012) + (xy 200.600983 78.038363) (xy 200.898363 77.740983) (xy 201.132012 77.391302) (xy 201.292953 77.002756) (xy 201.375 76.590279) + (xy 201.375 76.169721) (xy 201.305698 75.821318) (xy 201.521302 75.732012) (xy 201.870983 75.498363) (xy 202.071475 75.297871) + (xy 202.098815 75.331185) (xy 202.195506 75.410537) (xy 202.30582 75.469502) (xy 202.425518 75.505812) (xy 202.55 75.518072) + (xy 204.85 75.518072) (xy 204.974482 75.505812) (xy 205.09418 75.469502) (xy 205.204494 75.410537) (xy 205.29 75.340364) + (xy 205.290001 85.881514) (xy 205.29 85.881524) (xy 205.29 85.881531) (xy 205.285719 85.925) (xy 205.29 85.96847) + (xy 205.290001 86.881515) (xy 205.29 86.881524) (xy 205.29 87.114999) (xy 204.035 87.114999) (xy 204.035 87.10326) + (xy 204.002911 86.94194) (xy 203.96 86.838343) (xy 203.96 80.387322) (xy 203.963676 80.349999) (xy 203.96 80.312676) + (xy 203.96 80.312667) (xy 203.949003 80.201014) (xy 203.905546 80.057753) (xy 203.890843 80.030246) (xy 203.834974 79.925723) + (xy 203.763799 79.838997) (xy 203.740001 79.809999) (xy 203.711004 79.786202) (xy 202.282879 78.358078) (xy 202.239967 78.254479) + (xy 202.148587 78.117719) (xy 202.032281 78.001413) (xy 201.895521 77.910033) (xy 201.74356 77.847089) (xy 201.58224 77.815) + (xy 201.41776 77.815) (xy 201.25644 77.847089) (xy 201.104479 77.910033) (xy 200.967719 78.001413) (xy 200.851413 78.117719) + (xy 200.760033 78.254479) (xy 200.697089 78.40644) (xy 200.665 78.56776) (xy 200.665 78.73224) (xy 200.697089 78.89356) + (xy 200.760033 79.045521) (xy 200.851413 79.182281) (xy 200.967719 79.298587) (xy 201.104479 79.389967) (xy 201.208078 79.432879) + (xy 202.44 80.664802) (xy 202.440001 86.838341) (xy 202.397089 86.94194) (xy 202.365 87.10326) (xy 202.365 87.114999) + (xy 200.575616 87.114999) (xy 200.573911 87.106429) (xy 200.510967 86.954468) (xy 200.419587 86.817708) (xy 200.385838 86.783959) + (xy 200.430537 86.729494) (xy 200.489502 86.61918) (xy 200.525812 86.499482) (xy 200.538072 86.375) (xy 200.538072 85.81173) + (xy 200.934601 85.415201) (xy 200.995521 85.389967) (xy 201.132281 85.298587) (xy 201.248587 85.182281) (xy 201.339967 85.045521) + (xy 201.402911 84.89356) (xy 201.435 84.73224) (xy 201.435 84.56776) (xy 201.402911 84.40644) (xy 201.339967 84.254479) + (xy 201.248587 84.117719) (xy 201.132281 84.001413) (xy 200.995521 83.910033) (xy 200.84356 83.847089) (xy 200.68224 83.815) + (xy 200.535348 83.815) (xy 200.538072 83.625) (xy 200.525812 83.500518) (xy 200.489502 83.38082) (xy 200.430537 83.270506) + (xy 200.351185 83.173815) (xy 200.254494 83.094463) (xy 200.14418 83.035498) (xy 200.024482 82.999188) (xy 199.9 82.986928) + (xy 199.38575 82.99) (xy 199.227002 83.148748) (xy 199.227002 82.99) (xy 199.16 82.99) (xy 199.16 82.784877) + (xy 199.163435 82.75) (xy 199.149727 82.610816) (xy 199.109128 82.47698) (xy 199.0432 82.353637) (xy 198.954475 82.245525) + (xy 198.846363 82.1568) (xy 198.72302 82.090872) (xy 198.589184 82.050273) (xy 198.484877 82.04) (xy 198.45 82.036565) + (xy 198.415123 82.04) (xy 194.984877 82.04) (xy 194.95 82.036565) (xy 194.915123 82.04) (xy 194.810816 82.050273) + (xy 194.67698 82.090872) (xy 194.553637 82.1568) (xy 194.445525 82.245525) (xy 194.3568 82.353637) (xy 194.290872 82.47698) + (xy 194.250273 82.610816) (xy 194.236565 82.75) (xy 194.240001 82.784887) (xy 194.240001 82.986928) (xy 193.5 82.986928) + (xy 193.375518 82.999188) (xy 193.25582 83.035498) (xy 193.145506 83.094463) (xy 193.048815 83.173815) (xy 192.969463 83.270506) + (xy 192.918954 83.365) (xy 192.762322 83.365) (xy 192.724999 83.361324) (xy 192.687676 83.365) (xy 192.687667 83.365) + (xy 192.576014 83.375997) (xy 192.432753 83.419454) (xy 192.300724 83.490026) (xy 192.184999 83.584999) (xy 192.161201 83.613997) + (xy 191.458077 84.317121) (xy 191.354479 84.360033) (xy 191.217719 84.451413) (xy 191.101413 84.567719) (xy 191.010033 84.704479) + (xy 190.947089 84.85644) (xy 190.915 85.01776) (xy 190.915 85.18224) (xy 190.947089 85.34356) (xy 191.010033 85.495521) + (xy 191.101413 85.632281) (xy 191.217719 85.748587) (xy 191.354479 85.839967) (xy 191.50644 85.902911) (xy 191.66776 85.935) + (xy 191.83224 85.935) (xy 191.99356 85.902911) (xy 192.145521 85.839967) (xy 192.261137 85.762715) (xy 192.861928 86.363507) + (xy 192.861928 86.375) (xy 192.874188 86.499482) (xy 192.910498 86.61918) (xy 192.969463 86.729494) (xy 193.048815 86.826185) + (xy 193.145506 86.905537) (xy 193.25582 86.964502) (xy 193.375518 87.000812) (xy 193.415001 87.004701) (xy 193.415001 87.406521) + (xy 193.410719 87.45) (xy 193.427805 87.62349) (xy 193.478412 87.790313) (xy 193.56059 87.944059) (xy 193.643468 88.045046) + (xy 193.643471 88.045049) (xy 193.671184 88.078817) (xy 193.704952 88.10653) (xy 194.193465 88.595043) (xy 194.221182 88.628816) + (xy 194.35594 88.73941) (xy 194.509686 88.821588) (xy 194.578341 88.842414) (xy 194.320583 89.228175) (xy 194.118183 89.716814) + (xy 194.015 90.235551) (xy 194.015 90.764449) (xy 194.118183 91.283186) (xy 194.123749 91.296623) (xy 193.901302 91.147989) + (xy 193.592012 91.019877) (xy 193.627932 90.933158) (xy 193.685 90.64626) (xy 193.685 90.35374) (xy 193.627932 90.066842) + (xy 193.51599 89.796589) (xy 193.353475 89.553368) (xy 193.146632 89.346525) (xy 192.903411 89.18401) (xy 192.633158 89.072068) + (xy 192.34626 89.015) (xy 192.176697 89.015) (xy 192.082327 88.975911) (xy 191.776109 88.915) (xy 191.463891 88.915) + (xy 191.157673 88.975911) (xy 190.869221 89.095391) (xy 190.609621 89.26885) (xy 190.38885 89.489621) (xy 190.215391 89.749221) + (xy 190.095911 90.037673) (xy 190.035 90.343891) (xy 190.035 90.656109) (xy 190.095911 90.962327) (xy 190.215391 91.250779) + (xy 190.38885 91.510379) (xy 190.609621 91.73115) (xy 190.869221 91.904609) (xy 191.035016 91.973283) (xy 190.997988 92.028699) + (xy 190.837047 92.417245) (xy 190.755 92.829722) (xy 190.755 93.25028) (xy 190.837047 93.662757) (xy 190.969252 93.981928) + (xy 189.85 93.981928) (xy 189.725518 93.994188) (xy 189.60582 94.030498) (xy 189.495506 94.089463) (xy 189.398815 94.168815) + (xy 189.319463 94.265506) (xy 189.260498 94.37582) (xy 189.224188 94.495518) (xy 189.211928 94.62) (xy 189.211928 96.62) + (xy 189.224188 96.744482) (xy 189.260498 96.86418) (xy 189.319463 96.974494) (xy 189.398815 97.071185) (xy 189.495506 97.150537) + (xy 189.60582 97.209502) (xy 189.725518 97.245812) (xy 189.85 97.258072) (xy 191.61327 97.258072) (xy 192.329055 97.973858) + (xy 192.352849 98.002851) (xy 192.381842 98.026645) (xy 192.381846 98.026649) (xy 192.444506 98.078072) (xy 192.468574 98.097824) + (xy 192.600603 98.168396) (xy 192.743864 98.211853) (xy 192.855517 98.22285) (xy 192.855526 98.22285) (xy 192.892849 98.226526) + (xy 192.930172 98.22285) (xy 195.152346 98.22285) (xy 193.788998 99.586199) (xy 193.76 99.609997) (xy 193.736202 99.638995) + (xy 193.736201 99.638996) (xy 193.665026 99.725722) (xy 193.594454 99.857752) (xy 193.566692 99.949275) (xy 193.550998 100.001012) + (xy 193.542231 100.090026) (xy 193.536324 100.149998) (xy 193.540001 100.18733) (xy 193.54 101.986928) (xy 193.5 101.986928) + (xy 193.375518 101.999188) (xy 193.25582 102.035498) (xy 193.145506 102.094463) (xy 193.048815 102.173815) (xy 192.969463 102.270506) + (xy 192.910498 102.38082) (xy 192.874188 102.500518) (xy 192.861928 102.625) (xy 192.861928 103.063271) (xy 192.742704 103.182494) + (xy 192.639106 103.225406) (xy 192.589831 103.25833) (xy 192.440313 103.178412) (xy 192.27349 103.127805) (xy 192.1 103.110719) + (xy 191.92651 103.127805) (xy 191.759687 103.178412) (xy 191.605941 103.26059) (xy 191.471183 103.371183) (xy 191.36059 103.505941) + (xy 191.278412 103.659687) (xy 191.227805 103.82651) (xy 191.210719 104) (xy 191.227805 104.17349) (xy 191.278412 104.340313) + (xy 191.36059 104.494059) (xy 191.443468 104.595046) (xy 192.31847 105.470049) (xy 192.346183 105.503817) (xy 192.379951 105.53153) + (xy 192.379953 105.531532) (xy 192.434029 105.575911) (xy 192.480941 105.614411) (xy 192.634687 105.696589) (xy 192.80151 105.747195) + (xy 192.931523 105.76) (xy 192.931531 105.76) (xy 192.975 105.764281) (xy 192.996291 105.762184) (xy 193.048815 105.826185) + (xy 193.145506 105.905537) (xy 193.25582 105.964502) (xy 193.375518 106.000812) (xy 193.5 106.013072) (xy 194.24 106.013072) + (xy 194.24 106.215123) (xy 194.236565 106.25) (xy 194.250273 106.389184) (xy 194.290872 106.52302) (xy 194.3568 106.646363) + (xy 194.445525 106.754475) (xy 194.540291 106.832247) (xy 194.553637 106.8432) (xy 194.67698 106.909128) (xy 194.810816 106.949727) + (xy 194.95 106.963435) (xy 194.984877 106.96) (xy 195.815858 106.96) (xy 195.428175 107.120583) (xy 194.988412 107.414424) + (xy 194.614424 107.788412) (xy 194.320583 108.228175) (xy 194.118183 108.716814) (xy 194.015 109.235551) (xy 194.015 109.764449) + (xy 194.118183 110.283186) (xy 194.123749 110.296623) (xy 193.901302 110.147989) (xy 193.592012 110.019877) (xy 193.627932 109.933158) + (xy 193.685 109.64626) (xy 193.685 109.35374) (xy 193.627932 109.066842) (xy 193.51599 108.796589) (xy 193.353475 108.553368) + (xy 193.146632 108.346525) (xy 192.903411 108.18401) (xy 192.633158 108.072068) (xy 192.34626 108.015) (xy 192.176697 108.015) + (xy 192.082327 107.975911) (xy 191.776109 107.915) (xy 191.463891 107.915) (xy 191.157673 107.975911) (xy 190.869221 108.095391) + (xy 190.609621 108.26885) (xy 190.38885 108.489621) (xy 190.215391 108.749221) (xy 190.095911 109.037673) (xy 190.035 109.343891) + (xy 190.035 109.656109) (xy 190.095911 109.962327) (xy 190.215391 110.250779) (xy 190.38885 110.510379) (xy 190.609621 110.73115) + (xy 190.869221 110.904609) (xy 191.035016 110.973283) (xy 190.997988 111.028699) (xy 190.837047 111.417245) (xy 190.755 111.829722) + (xy 190.755 112.25028) (xy 190.837047 112.662757) (xy 190.969252 112.981928) (xy 189.85 112.981928) (xy 189.725518 112.994188) + (xy 189.60582 113.030498) (xy 189.495506 113.089463) (xy 189.436818 113.137627) (xy 189.395521 113.110033) (xy 189.291922 113.067121) + (xy 189.2915 113.066699) (xy 189.2915 109.725846) (xy 189.329494 109.705537) (xy 189.426185 109.626185) (xy 189.505537 109.529494) + (xy 189.564502 109.41918) (xy 189.600812 109.299482) (xy 189.613072 109.175) (xy 189.613072 107.875) (xy 189.600812 107.750518) + (xy 189.564502 107.63082) (xy 189.505537 107.520506) (xy 189.426185 107.423815) (xy 189.329494 107.344463) (xy 189.21918 107.285498) + (xy 189.099482 107.249188) (xy 188.975 107.236928) (xy 188.025 107.236928) (xy 187.900518 107.249188) (xy 187.78082 107.285498) + (xy 187.670506 107.344463) (xy 187.573815 107.423815) (xy 187.494463 107.520506) (xy 187.435498 107.63082) (xy 187.399188 107.750518) + (xy 187.386928 107.875) (xy 187.386928 109.175) (xy 187.399188 109.299482) (xy 187.435498 109.41918) (xy 187.494463 109.529494) + (xy 187.573815 109.626185) (xy 187.670506 109.705537) (xy 187.771501 109.759521) (xy 187.7715 113.344177) (xy 187.767824 113.3815) + (xy 187.7715 113.418822) (xy 187.7715 113.418832) (xy 187.782497 113.530485) (xy 187.813746 113.633501) (xy 187.825954 113.673746) + (xy 187.896526 113.805776) (xy 187.92327 113.838363) (xy 187.991499 113.921501) (xy 188.020503 113.945304) (xy 188.217121 114.141922) + (xy 188.240001 114.197159) (xy 188.24 115.212677) (xy 188.236324 115.25) (xy 188.24 115.287322) (xy 188.24 115.287332) + (xy 188.250997 115.398985) (xy 188.290959 115.530725) (xy 188.294454 115.542246) (xy 188.365026 115.674276) (xy 188.397475 115.713815) + (xy 188.459999 115.790001) (xy 188.489003 115.813804) (xy 190.440198 117.765) (xy 189.906523 117.765) (xy 189.77651 117.777805) + (xy 189.609687 117.828411) (xy 189.455941 117.910589) (xy 189.321183 118.021183) (xy 189.210589 118.155941) (xy 189.128411 118.309687) + (xy 189.077805 118.47651) (xy 189.060718 118.65) (xy 189.077805 118.82349) (xy 189.117654 118.954853) (xy 189.095304 118.932503) + (xy 189.071501 118.903499) (xy 188.955776 118.808526) (xy 188.855995 118.755191) (xy 188.839502 118.70082) (xy 188.780537 118.590506) + (xy 188.701185 118.493815) (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) (xy 188.25 118.306928) + (xy 186.25 118.306928) (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) (xy 185.798815 118.493815) + (xy 185.719463 118.590506) (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) (xy 185.611928 119.945) + (xy 185.624188 120.069482) (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) (xy 185.719463 120.340506) + (xy 185.660498 120.45082) (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.260001) (xy 184.488072 121.260001) + (xy 184.488072 120.695) (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) (xy 184.363708 120.32) + (xy 184.380537 120.299494) (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) (xy 184.485 119.73075) + (xy 184.32625 119.572) (xy 182.977 119.572) (xy 182.977 119.592) (xy 182.723 119.592) (xy 182.723 119.572) + (xy 182.703 119.572) (xy 182.703 119.318) (xy 182.723 119.318) (xy 182.723 119.298) (xy 182.977 119.298) + (xy 182.977 119.318) (xy 184.32625 119.318) (xy 184.485 119.15925) (xy 184.488072 118.945) (xy 184.475812 118.820518) + (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) (xy 184.379711 118.35376) + (xy 184.4118 118.19244) (xy 184.4118 118.02796) (xy 184.379711 117.86664) (xy 184.316767 117.714679) (xy 184.225387 117.577919) + (xy 184.109081 117.461613) (xy 183.972321 117.370233) (xy 183.82036 117.307289) (xy 183.65904 117.2752) (xy 183.49456 117.2752) + (xy 183.33324 117.307289) (xy 183.181279 117.370233) (xy 183.044519 117.461613) (xy 183.003532 117.5026) (xy 182.120557 117.5026) + (xy 182.01696 117.459689) (xy 181.85564 117.4276) (xy 181.69116 117.4276) (xy 181.52984 117.459689) (xy 181.377879 117.522633) + (xy 181.299353 117.575103) (xy 181.27625 117.552) (xy 180.127 117.552) (xy 180.127 117.572) (xy 180.0588 117.572) + (xy 180.0588 117.278) (xy 180.127 117.278) (xy 180.127 117.298) (xy 181.27625 117.298) (xy 181.435 117.13925) + (xy 181.438072 116.925) (xy 181.425812 116.800518) (xy 181.389502 116.68082) (xy 181.330537 116.570506) (xy 181.251185 116.473815) + (xy 181.154494 116.394463) (xy 181.04418 116.335498) (xy 180.924482 116.299188) (xy 180.8 116.286928) (xy 180.28575 116.29) + (xy 180.127002 116.448748) (xy 180.127002 116.29) (xy 180.0588 116.29) (xy 180.0588 116.070077) (xy 180.062235 116.0352) + (xy 180.048527 115.896016) (xy 180.007928 115.76218) (xy 179.942 115.638837) (xy 179.853275 115.530725) (xy 179.745163 115.442) + (xy 179.62182 115.376072) (xy 179.487984 115.335473) (xy 179.383677 115.3252) (xy 179.3488 115.321765) (xy 179.313923 115.3252) + (xy 175.883677 115.3252) (xy 175.863196 115.323183) (xy 175.848587 115.301319) (xy 175.732281 115.185013) (xy 175.595521 115.093633) + (xy 175.44356 115.030689) (xy 175.28224 114.9986) (xy 175.11776 114.9986) (xy 174.95644 115.030689) (xy 174.804479 115.093633) + (xy 174.667719 115.185013) (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) (xy 174.365 115.75136) + (xy 174.365 115.91584) (xy 174.397089 116.07716) (xy 174.44 116.180757) (xy 174.44 116.286928) (xy 174.4 116.286928) + (xy 174.275518 116.299188) (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.869463 116.570506) + (xy 173.810498 116.68082) (xy 173.774188 116.800518) (xy 173.761928 116.925) (xy 173.761928 117.453) (xy 173.74096 117.453) + (xy 173.6168 117.477697) (xy 173.6168 117.31676) (xy 173.584711 117.15544) (xy 173.521767 117.003479) (xy 173.430387 116.866719) + (xy 173.314081 116.750413) (xy 173.177321 116.659033) (xy 173.02536 116.596089) (xy 172.86404 116.564) (xy 172.729 116.564) + (xy 172.729 115.612557) (xy 172.771911 115.50896) (xy 172.804 115.34764) (xy 172.804 115.18316) (xy 172.771911 115.02184) + (xy 172.708967 114.869879) (xy 172.617587 114.733119) (xy 172.501281 114.616813) (xy 172.364521 114.525433) (xy 172.21256 114.462489) + (xy 172.05124 114.4304) (xy 171.88676 114.4304) (xy 171.72544 114.462489) (xy 171.573479 114.525433) (xy 171.436719 114.616813) + (xy 171.320413 114.733119) (xy 171.229033 114.869879) (xy 171.166089 115.02184) (xy 171.134 115.18316) (xy 171.134 115.34764) + (xy 171.166089 115.50896) (xy 171.209 115.612557) (xy 171.209001 119.921198) (xy 167.388072 123.742128) (xy 167.388072 122.87) + (xy 167.375812 122.745518) (xy 167.339502 122.62582) (xy 167.280537 122.515506) (xy 167.201185 122.418815) (xy 167.104494 122.339463) + (xy 166.99418 122.280498) (xy 166.874482 122.244188) (xy 166.75 122.231928) (xy 164.956887 122.231928) (xy 165.084609 122.040779) + (xy 165.204089 121.752327) (xy 165.265 121.446109) (xy 165.265 121.133891) (xy 165.204089 120.827673) (xy 165.084609 120.539221) + (xy 164.91115 120.279621) (xy 164.690379 120.05885) (xy 164.430779 119.885391) (xy 164.142327 119.765911) (xy 163.836109 119.705) + (xy 163.523891 119.705) (xy 163.217673 119.765911) (xy 163.123303 119.805) (xy 162.95374 119.805) (xy 162.666842 119.862068) + (xy 162.396589 119.97401) (xy 162.153368 120.136525) (xy 161.946525 120.343368) (xy 161.78401 120.586589) (xy 161.672068 120.856842) + (xy 161.615 121.14374) (xy 161.615 121.43626) (xy 161.672068 121.723158) (xy 161.707988 121.809876) (xy 161.398698 121.937988) + (xy 161.176252 122.086622) (xy 161.181817 122.073186) (xy 161.285 121.554449) (xy 161.285 121.025551) (xy 161.181817 120.506814) + (xy 160.979417 120.018175) (xy 160.750114 119.674999) (xy 160.911927 119.674999) (xy 160.949249 119.678675) (xy 160.986571 119.674999) + (xy 160.986582 119.674999) (xy 161.098235 119.664002) (xy 161.241496 119.620545) (xy 161.373525 119.549973) (xy 161.48925 119.455) + (xy 161.513053 119.425996) (xy 166.460999 114.478051) (xy 166.489997 114.454253) (xy 166.58497 114.338528) (xy 166.655542 114.206499) + (xy 166.698999 114.063237) (xy 166.706509 113.986984) (xy 166.752907 113.87497) (xy 166.754612 113.8664) (xy 183.798742 113.8664) + (xy 183.836064 113.870076) (xy 183.873386 113.8664) (xy 183.873397 113.8664) (xy 183.98505 113.855403) (xy 184.128311 113.811946) + (xy 184.26034 113.741374) (xy 184.376065 113.646401) (xy 184.399867 113.617398) (xy 184.925455 113.09181) (xy 185.029053 113.048899) + (xy 185.165813 112.957519) (xy 185.282119 112.841213) (xy 185.373499 112.704453) (xy 185.436443 112.552492) (xy 185.468532 112.391172) + (xy 185.468532 112.226692) (xy 185.436443 112.065372) (xy 185.373499 111.913411) (xy 185.282119 111.776651) (xy 185.165813 111.660345) + (xy 185.029053 111.568965) (xy 184.877092 111.506021) (xy 184.715772 111.473932) (xy 184.551292 111.473932) (xy 184.389972 111.506021) + (xy 184.238011 111.568965) (xy 184.101251 111.660345) (xy 183.984945 111.776651) (xy 183.893565 111.913411) (xy 183.850654 112.017009) + (xy 183.521263 112.3464) (xy 182.378401 112.3464) (xy 185.111003 109.613799) (xy 185.140001 109.590001) (xy 185.181036 109.54) + (xy 185.234974 109.474277) (xy 185.305546 109.342247) (xy 185.320315 109.29356) (xy 185.349003 109.198986) (xy 185.36 109.087333) + (xy 185.36 109.087324) (xy 185.363676 109.050001) (xy 185.36 109.012678) (xy 185.36 108.918072) (xy 185.75 108.918072) + (xy 185.874482 108.905812) (xy 185.99418 108.869502) (xy 186.104494 108.810537) (xy 186.201185 108.731185) (xy 186.280537 108.634494) + (xy 186.339502 108.52418) (xy 186.375812 108.404482) (xy 186.388072 108.28) (xy 186.388072 106.28) (xy 186.375812 106.155518) + (xy 186.339502 106.03582) (xy 186.280537 105.925506) (xy 186.201185 105.828815) (xy 186.104494 105.749463) (xy 185.99418 105.690498) + (xy 185.874482 105.654188) (xy 185.75 105.641928) (xy 183.956887 105.641928) (xy 184.084609 105.450779) (xy 184.204089 105.162327) + (xy 184.265 104.856109) (xy 184.265 104.543891) (xy 184.22146 104.325) (xy 187.386928 104.325) (xy 187.386928 105.625) + (xy 187.399188 105.749482) (xy 187.435498 105.86918) (xy 187.494463 105.979494) (xy 187.573815 106.076185) (xy 187.670506 106.155537) + (xy 187.78082 106.214502) (xy 187.900518 106.250812) (xy 188.025 106.263072) (xy 188.650908 106.263072) (xy 188.738913 106.394781) + (xy 188.855219 106.511087) (xy 188.991979 106.602467) (xy 189.14394 106.665411) (xy 189.30526 106.6975) (xy 189.46974 106.6975) + (xy 189.63106 106.665411) (xy 189.783021 106.602467) (xy 189.919781 106.511087) (xy 190.036087 106.394781) (xy 190.127467 106.258021) + (xy 190.190411 106.10606) (xy 190.2225 105.94474) (xy 190.2225 105.78026) (xy 190.190411 105.61894) (xy 190.127467 105.466979) + (xy 190.036087 105.330219) (xy 189.919781 105.213913) (xy 189.783021 105.122533) (xy 189.679423 105.079622) (xy 189.613072 105.01327) + (xy 189.613072 104.325) (xy 189.600812 104.200518) (xy 189.564502 104.08082) (xy 189.505537 103.970506) (xy 189.426185 103.873815) + (xy 189.329494 103.794463) (xy 189.21918 103.735498) (xy 189.099482 103.699188) (xy 188.975 103.686928) (xy 188.025 103.686928) + (xy 187.900518 103.699188) (xy 187.78082 103.735498) (xy 187.670506 103.794463) (xy 187.573815 103.873815) (xy 187.494463 103.970506) + (xy 187.435498 104.08082) (xy 187.399188 104.200518) (xy 187.386928 104.325) (xy 184.22146 104.325) (xy 184.204089 104.237673) + (xy 184.084609 103.949221) (xy 183.91115 103.689621) (xy 183.690379 103.46885) (xy 183.430779 103.295391) (xy 183.142327 103.175911) + (xy 182.836109 103.115) (xy 182.523891 103.115) (xy 182.217673 103.175911) (xy 182.123303 103.215) (xy 181.95374 103.215) + (xy 181.666842 103.272068) (xy 181.396589 103.38401) (xy 181.153368 103.546525) (xy 180.946525 103.753368) (xy 180.78401 103.996589) + (xy 180.672068 104.266842) (xy 180.615 104.55374) (xy 180.615 104.84626) (xy 180.672068 105.133158) (xy 180.707988 105.219876) + (xy 180.398698 105.347988) (xy 180.176252 105.496622) (xy 180.181817 105.483186) (xy 180.285 104.964449) (xy 180.285 104.435551) + (xy 180.181817 103.916814) (xy 179.979417 103.428175) (xy 179.685576 102.988412) (xy 179.311588 102.614424) (xy 178.871825 102.320583) + (xy 178.725564 102.26) (xy 179.315123 102.26) (xy 179.35 102.263435) (xy 179.384877 102.26) (xy 179.489184 102.249727) + (xy 179.62302 102.209128) (xy 179.746363 102.1432) (xy 179.854475 102.054475) (xy 179.9432 101.946363) (xy 180.009128 101.82302) + (xy 180.049727 101.689184) (xy 180.063435 101.55) (xy 180.06 101.515123) (xy 180.06 101.213072) (xy 180.8 101.213072) + (xy 180.924482 101.200812) (xy 181.04418 101.164502) (xy 181.154494 101.105537) (xy 181.251185 101.026185) (xy 181.330537 100.929494) + (xy 181.389502 100.81918) (xy 181.425812 100.699482) (xy 181.438072 100.575) (xy 181.438072 99.92573) (xy 181.761004 99.602798) + (xy 181.790001 99.579001) (xy 181.884974 99.463276) (xy 181.913356 99.410177) (xy 181.989967 99.295521) (xy 182.052911 99.14356) + (xy 182.085 98.98224) (xy 182.085 98.81776) (xy 182.052911 98.65644) (xy 181.989967 98.504479) (xy 181.898587 98.367719) + (xy 181.782281 98.251413) (xy 181.645521 98.160033) (xy 181.49356 98.097089) (xy 181.396473 98.077777) (xy 181.435 98.03925) + (xy 181.438072 97.825) (xy 181.425812 97.700518) (xy 181.389502 97.58082) (xy 181.330537 97.470506) (xy 181.251185 97.373815) + (xy 181.154494 97.294463) (xy 181.04418 97.235498) (xy 180.924482 97.199188) (xy 180.8 97.186928) (xy 180.28575 97.19) + (xy 180.127002 97.348748) (xy 180.127002 97.19) (xy 180.06 97.19) (xy 180.06 97.084877) (xy 180.063435 97.05) + (xy 180.049727 96.910816) (xy 180.009128 96.77698) (xy 179.9432 96.653637) (xy 179.854475 96.545525) (xy 179.746363 96.4568) + (xy 179.62302 96.390872) (xy 179.489184 96.350273) (xy 179.384877 96.34) (xy 179.35 96.336565) (xy 179.315123 96.34) + (xy 175.884877 96.34) (xy 175.85 96.336565) (xy 175.815123 96.34) (xy 175.710816 96.350273) (xy 175.57698 96.390872) + (xy 175.453637 96.4568) (xy 175.345525 96.545525) (xy 175.2568 96.653637) (xy 175.190872 96.77698) (xy 175.150273 96.910816) + (xy 175.136565 97.05) (xy 175.140001 97.084887) (xy 175.140001 97.186928) (xy 174.4 97.186928) (xy 174.275518 97.199188) + (xy 174.15582 97.235498) (xy 174.045506 97.294463) (xy 173.948815 97.373815) (xy 173.869463 97.470506) (xy 173.810498 97.58082) + (xy 173.798882 97.619111) (xy 173.797753 97.619454) (xy 173.665723 97.690026) (xy 173.59386 97.749003) (xy 173.549999 97.784999) + (xy 173.5262 97.813998) (xy 172.989002 98.351197) (xy 172.959999 98.374999) (xy 172.919797 98.423986) (xy 172.865026 98.490724) + (xy 172.814634 98.585) (xy 172.794454 98.622754) (xy 172.750997 98.766015) (xy 172.749669 98.779501) (xy 172.697089 98.90644) + (xy 172.665 99.06776) (xy 172.665 99.076799) (xy 172.659687 99.078411) (xy 172.505941 99.160589) (xy 172.371183 99.271183) + (xy 172.260589 99.405941) (xy 172.178411 99.559687) (xy 172.127805 99.72651) (xy 172.110718 99.9) (xy 172.127805 100.07349) + (xy 172.178411 100.240313) (xy 172.260589 100.394059) (xy 172.371183 100.528817) (xy 172.505941 100.639411) (xy 172.659687 100.721589) + (xy 172.82651 100.772195) (xy 172.956523 100.785) (xy 173.80013 100.785) (xy 173.810498 100.81918) (xy 173.869463 100.929494) + (xy 173.948815 101.026185) (xy 174.045506 101.105537) (xy 174.15582 101.164502) (xy 174.275518 101.200812) (xy 174.4 101.213072) + (xy 175.14 101.213072) (xy 175.14 101.515123) (xy 175.136565 101.55) (xy 175.150273 101.689184) (xy 175.190872 101.82302) + (xy 175.2568 101.946363) (xy 175.345525 102.054475) (xy 175.430471 102.124188) (xy 175.453637 102.1432) (xy 175.57698 102.209128) + (xy 175.710816 102.249727) (xy 175.85 102.263435) (xy 175.884877 102.26) (xy 176.474436 102.26) (xy 176.328175 102.320583) + (xy 175.888412 102.614424) (xy 175.514424 102.988412) (xy 175.220583 103.428175) (xy 175.018183 103.916814) (xy 174.915 104.435551) + (xy 174.915 104.964449) (xy 175.018183 105.483186) (xy 175.023749 105.496623) (xy 174.801302 105.347989) (xy 174.492012 105.219877) + (xy 174.527932 105.133158) (xy 174.585 104.84626) (xy 174.585 104.55374) (xy 174.527932 104.266842) (xy 174.41599 103.996589) + (xy 174.253475 103.753368) (xy 174.046632 103.546525) (xy 173.803411 103.38401) (xy 173.533158 103.272068) (xy 173.24626 103.215) + (xy 173.076697 103.215) (xy 172.982327 103.175911) (xy 172.676109 103.115) (xy 172.363891 103.115) (xy 172.057673 103.175911) + (xy 171.769221 103.295391) (xy 171.509621 103.46885) (xy 171.28885 103.689621) (xy 171.115391 103.949221) (xy 170.995911 104.237673) + (xy 170.935 104.543891) (xy 170.935 104.856109) (xy 170.995911 105.162327) (xy 171.115391 105.450779) (xy 171.28885 105.710379) + (xy 171.509621 105.93115) (xy 171.769221 106.104609) (xy 171.935016 106.173283) (xy 171.897988 106.228699) (xy 171.737047 106.617245) + (xy 171.655 107.029722) (xy 171.655 107.45028) (xy 171.737047 107.862757) (xy 171.869252 108.181928) (xy 170.75 108.181928) + (xy 170.625518 108.194188) (xy 170.50582 108.230498) (xy 170.395506 108.289463) (xy 170.336818 108.337627) (xy 170.295521 108.310033) + (xy 170.191923 108.267122) (xy 170.01 108.085199) (xy 170.01 105.142683) (xy 170.079494 105.105537) (xy 170.176185 105.026185) + (xy 170.255537 104.929494) (xy 170.314502 104.81918) (xy 170.350812 104.699482) (xy 170.363072 104.575) (xy 170.363072 103.275) + (xy 170.350812 103.150518) (xy 170.314502 103.03082) (xy 170.255537 102.920506) (xy 170.176185 102.823815) (xy 170.079494 102.744463) + (xy 169.96918 102.685498) (xy 169.849482 102.649188) (xy 169.725 102.636928) (xy 168.775 102.636928) (xy 168.650518 102.649188) + (xy 168.53082 102.685498) (xy 168.420506 102.744463) (xy 168.323815 102.823815) (xy 168.244463 102.920506) (xy 168.185498 103.03082) + (xy 168.149188 103.150518) (xy 168.136928 103.275) (xy 168.136928 104.575) (xy 168.149188 104.699482) (xy 168.185498 104.81918) + (xy 168.244463 104.929494) (xy 168.323815 105.026185) (xy 168.420506 105.105537) (xy 168.49 105.142683) (xy 168.490001 108.362668) + (xy 168.486324 108.4) (xy 168.490001 108.437333) (xy 168.500998 108.548986) (xy 168.50721 108.569463) (xy 168.544454 108.692246) + (xy 168.615026 108.824276) (xy 168.675829 108.898364) (xy 168.71 108.940001) (xy 168.738998 108.963799) (xy 169.117122 109.341923) + (xy 169.140001 109.397159) (xy 169.14 110.485673) (xy 169.136324 110.522996) (xy 169.14 110.560318) (xy 169.14 110.560328) + (xy 169.150997 110.671981) (xy 169.19119 110.804482) (xy 169.194454 110.815242) (xy 169.265026 110.947272) (xy 169.28823 110.975546) + (xy 169.359999 111.062997) (xy 169.389003 111.0868) (xy 170.648602 112.3464) (xy 168.483846 112.3464) (xy 168.543367 112.257321) + (xy 168.606311 112.10536) (xy 168.6384 111.94404) (xy 168.6384 111.77956) (xy 168.606311 111.61824) (xy 168.543367 111.466279) + (xy 168.451987 111.329519) (xy 168.335681 111.213213) (xy 168.198921 111.121833) (xy 168.04696 111.058889) (xy 167.88564 111.0268) + (xy 167.72116 111.0268) (xy 167.55984 111.058889) (xy 167.456243 111.1018) (xy 166.764397 111.1018) (xy 166.66855 111.062099) + (xy 166.50723 111.03001) (xy 166.34275 111.03001) (xy 166.18143 111.062099) (xy 166.029469 111.125043) (xy 165.892709 111.216423) + (xy 165.776403 111.332729) (xy 165.685023 111.469489) (xy 165.622079 111.62145) (xy 165.58999 111.78277) (xy 165.58999 111.94725) + (xy 165.622079 112.10857) (xy 165.685023 112.260531) (xy 165.742399 112.3464) (xy 163.836311 112.3464) (xy 163.798988 112.342724) + (xy 163.761666 112.3464) (xy 163.761655 112.3464) (xy 163.650002 112.357397) (xy 163.521391 112.39641) (xy 163.500209 112.39641) + (xy 163.371598 112.357397) (xy 163.259945 112.3464) (xy 163.259934 112.3464) (xy 163.222612 112.342724) (xy 163.18529 112.3464) + (xy 156.751823 112.3464) (xy 156.7145 112.342724) (xy 156.677177 112.3464) (xy 156.677168 112.3464) (xy 156.565515 112.357397) + (xy 156.422254 112.400854) (xy 156.290225 112.471426) (xy 156.1745 112.566399) (xy 156.150701 112.595398) (xy 155.688998 113.057102) + (xy 155.66 113.0809) (xy 155.636202 113.109898) (xy 155.636201 113.109899) (xy 155.565026 113.196625) (xy 155.494454 113.328655) + (xy 155.472514 113.400984) (xy 155.450998 113.471915) (xy 155.442078 113.562481) (xy 155.436324 113.620901) (xy 155.440001 113.658233) + (xy 155.440001 113.776928) (xy 155.4 113.776928) (xy 155.275518 113.789188) (xy 155.15582 113.825498) (xy 155.045506 113.884463) + (xy 154.948815 113.963815) (xy 154.869463 114.060506) (xy 154.810498 114.17082) (xy 154.777728 114.278848) (xy 154.775524 114.280026) + (xy 154.659799 114.374999) (xy 154.636 114.403998) (xy 154.287602 114.752397) (xy 154.258599 114.776199) (xy 154.217716 114.826016) + (xy 154.163626 114.891924) (xy 154.1298 114.955208) (xy 154.1298 114.83276) (xy 154.097711 114.67144) (xy 154.034767 114.519479) + (xy 153.943387 114.382719) (xy 153.827081 114.266413) (xy 153.690321 114.175033) (xy 153.53836 114.112089) (xy 153.37704 114.08) + (xy 153.21256 114.08) (xy 153.05124 114.112089) (xy 152.899279 114.175033) (xy 152.762519 114.266413) (xy 152.646213 114.382719) + (xy 152.554833 114.519479) (xy 152.491889 114.67144) (xy 152.4598 114.83276) (xy 152.4598 114.99724) (xy 152.491889 115.15856) + (xy 152.534801 115.262159) (xy 152.5348 116.30185) (xy 152.52778 116.298098) (xy 152.408082 116.261788) (xy 152.2836 116.249528) + (xy 150.2836 116.249528) (xy 150.159118 116.261788) (xy 150.03942 116.298098) (xy 149.929106 116.357063) (xy 149.832415 116.436415) + (xy 149.753063 116.533106) (xy 149.694098 116.64342) (xy 149.657788 116.763118) (xy 149.645528 116.8876) (xy 149.645528 117.8876) + (xy 149.657788 118.012082) (xy 149.694098 118.13178) (xy 149.753063 118.242094) (xy 149.769892 118.2626) (xy 149.753063 118.283106) + (xy 149.694098 118.39342) (xy 149.657788 118.513118) (xy 149.645528 118.6376) (xy 149.645528 118.789227) (xy 149.482903 118.626602) + (xy 149.459101 118.597599) (xy 149.343376 118.502626) (xy 149.211347 118.432054) (xy 149.068086 118.388597) (xy 148.956433 118.3776) + (xy 148.956422 118.3776) (xy 148.9191 118.373924) (xy 148.881778 118.3776) (xy 148.464646 118.3776) (xy 148.414137 118.283106) + (xy 148.397308 118.2626) (xy 148.414137 118.242094) (xy 148.473102 118.13178) (xy 148.509412 118.012082) (xy 148.521672 117.8876) + (xy 148.5186 117.67335) (xy 148.35985 117.5146) (xy 147.0106 117.5146) (xy 147.0106 117.5346) (xy 146.7566 117.5346) + (xy 146.7566 117.5146) (xy 146.7366 117.5146) (xy 146.7366 117.2606) (xy 146.7566 117.2606) (xy 146.7566 116.41135) + (xy 147.0106 116.41135) (xy 147.0106 117.2606) (xy 148.35985 117.2606) (xy 148.5186 117.10185) (xy 148.521672 116.8876) + (xy 148.509412 116.763118) (xy 148.473102 116.64342) (xy 148.414137 116.533106) (xy 148.334785 116.436415) (xy 148.238094 116.357063) + (xy 148.12778 116.298098) (xy 148.008082 116.261788) (xy 147.8836 116.249528) (xy 147.16935 116.2526) (xy 147.0106 116.41135) + (xy 146.7566 116.41135) (xy 146.59785 116.2526) (xy 145.8836 116.249528) (xy 145.759118 116.261788) (xy 145.63942 116.298098) + (xy 145.529106 116.357063) (xy 145.432415 116.436415) (xy 145.353063 116.533106) (xy 145.294098 116.64342) (xy 145.257788 116.763118) + (xy 145.245528 116.8876) (xy 145.2486 117.10185) (xy 145.407348 117.260598) (xy 145.2486 117.260598) (xy 145.2486 117.3768) + (xy 145.14056 117.3768) (xy 144.97924 117.408889) (xy 144.827279 117.471833) (xy 144.690519 117.563213) (xy 144.644333 117.609399) + (xy 144.592984 117.513334) (xy 144.581157 117.498923) (xy 144.498011 117.397609) (xy 144.469007 117.373806) (xy 144.253079 117.157878) + (xy 144.210167 117.054279) (xy 144.118787 116.917519) (xy 144.002481 116.801213) (xy 143.865721 116.709833) (xy 143.71376 116.646889) + (xy 143.55244 116.6148) (xy 143.38796 116.6148) (xy 143.304826 116.631337) (xy 143.289502 116.58082) (xy 143.230537 116.470506) + (xy 143.151185 116.373815) (xy 143.054494 116.294463) (xy 142.94418 116.235498) (xy 142.824482 116.199188) (xy 142.7 116.186928) + (xy 142.18575 116.19) (xy 142.027002 116.348748) (xy 142.027002 116.19) (xy 141.9604 116.19) (xy 141.9604 115.984077) + (xy 141.963835 115.9492) (xy 141.950127 115.810016) (xy 141.909528 115.67618) (xy 141.880882 115.622586) (xy 141.959787 115.543681) + (xy 142.051167 115.406921) (xy 142.114111 115.25496) (xy 142.1462 115.09364) (xy 142.1462 114.92916) (xy 142.114111 114.76784) + (xy 142.051167 114.615879) (xy 141.959787 114.479119) (xy 141.843481 114.362813) (xy 141.706721 114.271433) (xy 141.55476 114.208489) + (xy 141.39344 114.1764) (xy 141.22896 114.1764) (xy 141.06764 114.208489) (xy 140.964043 114.2514) (xy 138.224323 114.2514) + (xy 138.187 114.247724) (xy 138.149677 114.2514) (xy 138.149667 114.2514) (xy 138.038014 114.262397) (xy 137.910712 114.301013) + (xy 137.894753 114.305854) (xy 137.762723 114.376426) (xy 137.696956 114.4304) (xy 137.646999 114.471399) (xy 137.6232 114.500398) + (xy 137.26559 114.858009) (xy 137.160435 114.914216) (xy 137.04471 115.009189) (xy 137.020907 115.038193) (xy 136.588998 115.470102) + (xy 136.56 115.4939) (xy 136.536202 115.522898) (xy 136.536201 115.522899) (xy 136.465026 115.609625) (xy 136.394454 115.741655) + (xy 136.373569 115.810506) (xy 136.350998 115.884915) (xy 136.343445 115.961601) (xy 136.336324 116.033901) (xy 136.340001 116.071233) + (xy 136.340001 116.186928) (xy 136.3 116.186928) (xy 136.175518 116.199188) (xy 136.05582 116.235498) (xy 135.945506 116.294463) + (xy 135.848815 116.373815) (xy 135.769463 116.470506) (xy 135.710498 116.58082) (xy 135.674188 116.700518) (xy 135.661928 116.825) + (xy 135.661928 117.1228) (xy 135.53936 117.1228) (xy 135.37804 117.154889) (xy 135.226079 117.217833) (xy 135.089319 117.309213) + (xy 134.973013 117.425519) (xy 134.881633 117.562279) (xy 134.818689 117.71424) (xy 134.7866 117.87556) (xy 134.7866 118.04004) + (xy 134.818689 118.20136) (xy 134.881633 118.353321) (xy 134.911001 118.397274) (xy 134.866557 118.504572) (xy 134.834468 118.665892) + (xy 134.834468 118.830372) (xy 134.866557 118.991692) (xy 134.909469 119.095291) (xy 134.909468 120.203545) (xy 134.905792 120.240868) + (xy 134.909468 120.27819) (xy 134.909468 120.2782) (xy 134.920465 120.389853) (xy 134.955944 120.506814) (xy 134.963922 120.533114) + (xy 135.034494 120.665144) (xy 135.065331 120.702718) (xy 135.129467 120.780869) (xy 135.15847 120.804671) (xy 135.7688 121.415002) + (xy 135.792599 121.444001) (xy 135.908324 121.538974) (xy 136.040353 121.609546) (xy 136.183614 121.653003) (xy 136.295267 121.664) + (xy 136.295276 121.664) (xy 136.332599 121.667676) (xy 136.369922 121.664) (xy 137.738836 121.664) (xy 137.414424 121.988412) + (xy 137.120583 122.428175) (xy 136.918183 122.916814) (xy 136.815 123.435551) (xy 136.815 123.964449) (xy 136.918183 124.483186) + (xy 136.923749 124.496623) (xy 136.701302 124.347989) (xy 136.392012 124.219877) (xy 136.427932 124.133158) (xy 136.485 123.84626) + (xy 136.485 123.55374) (xy 136.427932 123.266842) (xy 136.31599 122.996589) (xy 136.153475 122.753368) (xy 135.946632 122.546525) + (xy 135.703411 122.38401) (xy 135.433158 122.272068) (xy 135.14626 122.215) (xy 134.976697 122.215) (xy 134.882327 122.175911) + (xy 134.576109 122.115) (xy 134.263891 122.115) (xy 133.957673 122.175911) (xy 133.669221 122.295391) (xy 133.409621 122.46885) + (xy 133.18885 122.689621) (xy 133.015391 122.949221) (xy 132.895911 123.237673) (xy 132.835 123.543891) (xy 132.835 123.856109) + (xy 132.895911 124.162327) (xy 133.015391 124.450779) (xy 133.18885 124.710379) (xy 133.409621 124.93115) (xy 133.669221 125.104609) + (xy 133.835016 125.173283) (xy 133.797988 125.228699) (xy 133.637047 125.617245) (xy 133.555 126.029722) (xy 133.555 126.45028) + (xy 133.637047 126.862757) (xy 133.769252 127.181928) (xy 132.65 127.181928) (xy 132.525518 127.194188) (xy 132.40582 127.230498) + (xy 132.295506 127.289463) (xy 132.198815 127.368815) (xy 132.119463 127.465506) (xy 132.060498 127.57582) (xy 132.024188 127.695518) + (xy 132.011928 127.82) (xy 132.011928 128.640326) (xy 130.5396 127.167999) (xy 130.5396 122.445157) (xy 130.582511 122.34156) + (xy 130.6146 122.18024) (xy 130.6146 122.01576) (xy 130.582511 121.85444) (xy 130.519567 121.702479) (xy 130.428187 121.565719) + (xy 130.311881 121.449413) (xy 130.175121 121.358033) (xy 130.071522 121.315121) (xy 129.845404 121.089003) (xy 129.821601 121.059999) + (xy 129.705876 120.965026) (xy 129.573847 120.894454) (xy 129.430586 120.850997) (xy 129.318933 120.84) (xy 129.318922 120.84) + (xy 129.2816 120.836324) (xy 129.244278 120.84) (xy 128.767683 120.84) (xy 128.730537 120.770506) (xy 128.651185 120.673815) + (xy 128.554494 120.594463) (xy 128.44418 120.535498) (xy 128.324482 120.499188) (xy 128.2 120.486928) (xy 126.9 120.486928) + (xy 126.775518 120.499188) (xy 126.65582 120.535498) (xy 126.545506 120.594463) (xy 126.448815 120.673815) (xy 126.369463 120.770506) + (xy 126.310498 120.88082) (xy 126.274188 121.000518) (xy 126.261928 121.125) (xy 126.261928 122.075) (xy 126.274188 122.199482) + (xy 126.310498 122.31918) (xy 126.369463 122.429494) (xy 126.448815 122.526185) (xy 126.545506 122.605537) (xy 126.65582 122.664502) + (xy 126.775518 122.700812) (xy 126.9 122.713072) (xy 128.2 122.713072) (xy 128.324482 122.700812) (xy 128.44418 122.664502) + (xy 128.554494 122.605537) (xy 128.651185 122.526185) (xy 128.730537 122.429494) (xy 128.767683 122.36) (xy 128.966799 122.36) + (xy 128.996721 122.389922) (xy 129.0196 122.445157) (xy 129.0196 123.365) (xy 128.91776 123.365) (xy 128.75644 123.397089) + (xy 128.746866 123.401055) (xy 128.730537 123.370506) (xy 128.651185 123.273815) (xy 128.554494 123.194463) (xy 128.44418 123.135498) + (xy 128.324482 123.099188) (xy 128.2 123.086928) (xy 126.9 123.086928) (xy 126.775518 123.099188) (xy 126.65582 123.135498) + (xy 126.545506 123.194463) (xy 126.448815 123.273815) (xy 126.369463 123.370506) (xy 126.310498 123.48082) (xy 126.274188 123.600518) + (xy 126.261928 123.725) (xy 126.261928 124.675) (xy 126.274188 124.799482) (xy 126.310498 124.91918) (xy 126.369463 125.029494) + (xy 126.448815 125.126185) (xy 126.545506 125.205537) (xy 126.65582 125.264502) (xy 126.775518 125.300812) (xy 126.9 125.313072) + (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) (xy 128.554494 125.205537) (xy 128.651185 125.126185) + (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) (xy 128.91776 125.035) (xy 129.019601 125.035) + (xy 129.019601 127.445468) (xy 129.015924 127.4828) (xy 129.019601 127.520133) (xy 129.030598 127.631786) (xy 129.036621 127.651642) + (xy 129.074054 127.775046) (xy 129.144626 127.907076) (xy 129.204773 127.980364) (xy 129.2396 128.022801) (xy 129.268598 128.046599) + (xy 131.841522 130.619524) (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) (xy 132.228879 131.067567) + (xy 132.38084 131.130511) (xy 132.54216 131.1626) (xy 132.70664 131.1626) (xy 132.86796 131.130511) (xy 133.019921 131.067567) + (xy 133.156681 130.976187) (xy 133.272987 130.859881) (xy 133.364367 130.723121) (xy 133.368454 130.713255) (xy 134.1002 131.445002) + (xy 134.123998 131.474) (xy 134.152996 131.497798) (xy 134.239722 131.568973) (xy 134.366218 131.636587) (xy 134.371752 131.639545) + (xy 134.515013 131.683002) (xy 134.626666 131.693999) (xy 134.626675 131.693999) (xy 134.663998 131.697675) (xy 134.701321 131.693999) + (xy 137.473 131.693999) (xy 137.426999 131.74) (xy 126.937322 131.74) (xy 126.899999 131.736324) (xy 126.862676 131.74) + (xy 126.862667 131.74) (xy 126.751014 131.750997) (xy 126.631235 131.787331) (xy 126.607753 131.794454) (xy 126.475723 131.865026) + (xy 126.394815 131.931426) (xy 126.359999 131.959999) (xy 126.336201 131.988997) (xy 125.789234 132.535964) (xy 125.789234 130.57257) + (xy 126.564013 130.364969) (xy 126.68108 130.320908) (xy 126.787302 130.254856) (xy 126.878596 130.169349) (xy 126.951455 130.067675) + (xy 127.003078 129.953741) (xy 127.031481 129.831924) (xy 127.035574 129.706907) (xy 127.015198 129.583494) (xy 126.49756 127.651642) + (xy 126.453499 127.534575) (xy 126.387447 127.428353) (xy 126.30194 127.337059) (xy 126.200266 127.2642) (xy 126.086332 127.212577) + (xy 125.964515 127.184174) (xy 125.839498 127.180081) (xy 125.716085 127.200457) (xy 123.982326 127.665016) (xy 124.030992 127.547526) + (xy 124.091903 127.241308) (xy 124.091903 126.92909) (xy 124.030992 126.622872) (xy 123.911512 126.33442) (xy 123.738053 126.07482) + (xy 123.517282 125.854049) (xy 123.257682 125.68059) (xy 122.96923 125.56111) (xy 122.663012 125.500199) (xy 122.350794 125.500199) + (xy 122.044576 125.56111) (xy 121.756124 125.68059) (xy 121.588772 125.792411) (xy 121.513508 125.807382) (xy 121.243255 125.919324) + (xy 121.000034 126.081839) (xy 120.793191 126.288682) (xy 120.630676 126.531903) (xy 120.518734 126.802156) (xy 120.461666 127.089054) + (xy 120.461666 127.381574) (xy 120.518734 127.668472) (xy 120.630676 127.938725) (xy 120.738829 128.100587) (xy 120.576595 128.208988) + (xy 120.285 128.500583) (xy 120.285 128.135551) (xy 120.181817 127.616814) (xy 119.979417 127.128175) (xy 119.685576 126.688412) + (xy 119.660219 126.663055) (xy 119.75644 126.702911) (xy 119.91776 126.735) (xy 120.08224 126.735) (xy 120.24356 126.702911) + (xy 120.395521 126.639967) (xy 120.532281 126.548587) (xy 120.648587 126.432281) (xy 120.739967 126.295521) (xy 120.802911 126.14356) + (xy 120.835 125.98224) (xy 120.835 125.81776) (xy 120.802911 125.65644) (xy 120.739967 125.504479) (xy 120.648587 125.367719) + (xy 120.532281 125.251413) (xy 120.511776 125.237712) (xy 120.539967 125.195521) (xy 120.602911 125.04356) (xy 120.635 124.88224) + (xy 120.635 124.71776) (xy 120.602911 124.55644) (xy 120.56 124.452843) (xy 120.56 124.427565) (xy 120.563676 124.390242) + (xy 120.56 124.352919) (xy 120.56 124.352911) (xy 120.549003 124.241257) (xy 120.505546 124.097996) (xy 120.434974 123.965967) + (xy 120.340001 123.850242) (xy 120.311003 123.826444) (xy 120.236894 123.752335) (xy 120.255947 123.67062) (xy 120.26004 123.545603) + (xy 120.239664 123.42219) (xy 120.15787 123.116931) (xy 120.291923 122.982878) (xy 120.395521 122.939967) (xy 120.532281 122.848587) + (xy 120.648587 122.732281) (xy 120.739967 122.595521) (xy 120.802911 122.44356) (xy 120.835 122.28224) (xy 120.835 122.11776) + (xy 120.802911 121.95644) (xy 120.739967 121.804479) (xy 120.648587 121.667719) (xy 120.631228 121.65036) (xy 121.8976 121.65036) + (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.992633 122.128121) (xy 122.084013 122.264881) (xy 122.200319 122.381187) + (xy 122.337079 122.472567) (xy 122.482012 122.5326) (xy 122.337079 122.592633) (xy 122.200319 122.684013) (xy 122.084013 122.800319) + (xy 121.992633 122.937079) (xy 121.929689 123.08904) (xy 121.8976 123.25036) (xy 121.8976 123.41484) (xy 121.929689 123.57616) + (xy 121.9726 123.679757) (xy 121.9726 123.895278) (xy 121.968924 123.9326) (xy 121.9726 123.969922) (xy 121.9726 123.969932) + (xy 121.983597 124.081585) (xy 122.021393 124.206185) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.135817 124.403411) + (xy 122.192599 124.472601) (xy 122.221603 124.496404) (xy 122.436196 124.710997) (xy 122.459999 124.740001) (xy 122.575724 124.834974) + (xy 122.707753 124.905546) (xy 122.762007 124.922004) (xy 122.819463 125.029494) (xy 122.898815 125.126185) (xy 122.995506 125.205537) + (xy 123.10582 125.264502) (xy 123.225518 125.300812) (xy 123.35 125.313072) (xy 124.65 125.313072) (xy 124.774482 125.300812) + (xy 124.89418 125.264502) (xy 125.004494 125.205537) (xy 125.101185 125.126185) (xy 125.180537 125.029494) (xy 125.239502 124.91918) + (xy 125.275812 124.799482) (xy 125.288072 124.675) (xy 125.288072 123.725) (xy 125.275812 123.600518) (xy 125.239502 123.48082) + (xy 125.180537 123.370506) (xy 125.101185 123.273815) (xy 125.004494 123.194463) (xy 124.89418 123.135498) (xy 124.774482 123.099188) + (xy 124.65 123.086928) (xy 123.534636 123.086928) (xy 123.472567 122.937079) (xy 123.381187 122.800319) (xy 123.287816 122.706948) + (xy 123.35 122.713072) (xy 124.65 122.713072) (xy 124.774482 122.700812) (xy 124.89418 122.664502) (xy 125.004494 122.605537) + (xy 125.101185 122.526185) (xy 125.180537 122.429494) (xy 125.239502 122.31918) (xy 125.275812 122.199482) (xy 125.288072 122.075) + (xy 125.288072 121.125) (xy 125.275812 121.000518) (xy 125.239502 120.88082) (xy 125.180537 120.770506) (xy 125.101185 120.673815) + (xy 125.004494 120.594463) (xy 124.89418 120.535498) (xy 124.774482 120.499188) (xy 124.65 120.486928) (xy 123.35 120.486928) + (xy 123.225518 120.499188) (xy 123.10582 120.535498) (xy 122.995506 120.594463) (xy 122.898815 120.673815) (xy 122.819463 120.770506) + (xy 122.779786 120.844736) (xy 122.716214 120.850997) (xy 122.572953 120.894454) (xy 122.517699 120.923988) (xy 122.48904 120.929689) + (xy 122.337079 120.992633) (xy 122.200319 121.084013) (xy 122.084013 121.200319) (xy 121.992633 121.337079) (xy 121.929689 121.48904) + (xy 121.8976 121.65036) (xy 120.631228 121.65036) (xy 120.532281 121.551413) (xy 120.395521 121.460033) (xy 120.24356 121.397089) + (xy 120.08224 121.365) (xy 119.91776 121.365) (xy 119.75644 121.397089) (xy 119.610392 121.457584) (xy 119.533884 121.413412) + (xy 118.423794 121.71086) (xy 118.42897 121.730178) (xy 118.41826 121.733048) (xy 118.342167 121.449065) (xy 118.352878 121.446195) + (xy 118.358054 121.465514) (xy 119.468144 121.168067) (xy 119.580397 120.973638) (xy 119.527912 120.765894) (xy 119.483852 120.648826) + (xy 119.417799 120.542605) (xy 119.332292 120.451311) (xy 119.230618 120.378452) (xy 119.116684 120.32683) (xy 118.994868 120.298425) + (xy 118.86985 120.294333) (xy 118.746437 120.314709) (xy 118.250505 120.450774) (xy 118.138253 120.645199) (xy 118.097166 120.491861) + (xy 118.086453 120.494731) (xy 118.027859 120.276054) (xy 118.022151 120.241484) (xy 118.009809 120.208692) (xy 118.009807 120.208684) + (xy 117.972887 120.11059) (xy 117.899032 119.991823) (xy 117.803427 119.889746) (xy 117.689744 119.808281) (xy 117.562352 119.750561) + (xy 117.426149 119.718803) (xy 117.286366 119.714227) (xy 117.286365 119.714227) (xy 117.182953 119.7313) (xy 117.182948 119.731301) + (xy 117.148377 119.737009) (xy 117.115583 119.749352) (xy 116.935 119.797739) (xy 116.935 119.71776) (xy 116.902911 119.55644) + (xy 116.839967 119.404479) (xy 116.748587 119.267719) (xy 116.632281 119.151413) (xy 116.495521 119.060033) (xy 116.34356 118.997089) + (xy 116.18224 118.965) (xy 116.01776 118.965) (xy 115.85644 118.997089) (xy 115.752843 119.04) (xy 114.91455 119.04) + (xy 114.877217 119.036323) (xy 114.839884 119.04) (xy 114.728231 119.050997) (xy 114.58497 119.094454) (xy 114.452941 119.165026) + (xy 114.337216 119.259999) (xy 114.313418 119.288997) (xy 113.555582 120.046834) (xy 113.639967 119.920542) (xy 113.702911 119.768581) + (xy 113.735 119.607261) (xy 113.735 119.442781) (xy 113.702911 119.281461) (xy 113.639967 119.1295) (xy 113.548587 118.99274) + (xy 113.515847 118.96) (xy 121.638999 118.96) (xy 121.990922 119.311923) (xy 122.033833 119.415521) (xy 122.125213 119.552281) + (xy 122.241519 119.668587) (xy 122.378279 119.759967) (xy 122.53024 119.822911) (xy 122.69156 119.855) (xy 122.853982 119.855) + (xy 122.928815 119.946185) (xy 123.025506 120.025537) (xy 123.13582 120.084502) (xy 123.255518 120.120812) (xy 123.38 120.133072) + (xy 124.68 120.133072) (xy 124.804482 120.120812) (xy 124.92418 120.084502) (xy 125.034494 120.025537) (xy 125.131185 119.946185) + (xy 125.210537 119.849494) (xy 125.269502 119.73918) (xy 125.305812 119.619482) (xy 125.318072 119.495) (xy 125.318072 119.25) + (xy 125.34064 119.25) (xy 125.50196 119.217911) (xy 125.653921 119.154967) (xy 125.790681 119.063587) (xy 125.906987 118.947281) + (xy 125.998367 118.810521) (xy 126.061311 118.65856) (xy 126.083899 118.545) (xy 126.291928 118.545) (xy 126.291928 119.495) + (xy 126.304188 119.619482) (xy 126.340498 119.73918) (xy 126.399463 119.849494) (xy 126.478815 119.946185) (xy 126.575506 120.025537) + (xy 126.68582 120.084502) (xy 126.805518 120.120812) (xy 126.93 120.133072) (xy 128.23 120.133072) (xy 128.354482 120.120812) + (xy 128.47418 120.084502) (xy 128.584494 120.025537) (xy 128.681185 119.946185) (xy 128.756018 119.855) (xy 128.76504 119.855) + (xy 128.92636 119.822911) (xy 129.078321 119.759967) (xy 129.215081 119.668587) (xy 129.331387 119.552281) (xy 129.422767 119.415521) + (xy 129.485711 119.26356) (xy 129.5178 119.10224) (xy 129.5178 118.93776) (xy 129.485711 118.77644) (xy 129.422767 118.624479) + (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) (xy 128.92636 118.217089) (xy 128.76504 118.185) + (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) (xy 128.47418 117.955498) (xy 128.354482 117.919188) + (xy 128.23 117.906928) (xy 126.93 117.906928) (xy 126.805518 117.919188) (xy 126.68582 117.955498) (xy 126.575506 118.014463) + (xy 126.478815 118.093815) (xy 126.399463 118.190506) (xy 126.340498 118.30082) (xy 126.304188 118.420518) (xy 126.291928 118.545) + (xy 126.083899 118.545) (xy 126.0934 118.49724) (xy 126.0934 118.33276) (xy 126.061311 118.17144) (xy 125.998367 118.019479) + (xy 125.9676 117.973433) (xy 125.9676 117.475157) (xy 126.010511 117.37156) (xy 126.032383 117.261602) (xy 129.99428 117.261602) + (xy 130.031602 117.265278) (xy 130.068924 117.261602) (xy 130.068935 117.261602) (xy 130.180588 117.250605) (xy 130.323849 117.207148) + (xy 130.455878 117.136576) (xy 130.571603 117.041603) (xy 130.595405 117.0126) (xy 131.284549 116.323456) (xy 131.313548 116.299658) + (xy 131.408521 116.183933) (xy 131.479093 116.051904) (xy 131.52255 115.908643) (xy 131.533547 115.79699) (xy 131.533547 115.796982) + (xy 131.537223 115.759657) (xy 131.533547 115.722332) (xy 131.533547 113.975704) (xy 131.576458 113.872107) (xy 131.608547 113.710787) + (xy 131.608547 113.546307) (xy 131.576458 113.384987) (xy 131.513514 113.233026) (xy 131.422134 113.096266) (xy 131.305828 112.97996) + (xy 131.169068 112.88858) (xy 131.017107 112.825636) (xy 130.855787 112.793547) (xy 130.691307 112.793547) (xy 130.529987 112.825636) + (xy 130.378026 112.88858) (xy 130.241266 112.97996) (xy 130.12496 113.096266) (xy 130.03358 113.233026) (xy 129.970636 113.384987) + (xy 129.938547 113.546307) (xy 129.938547 113.710787) (xy 129.970636 113.872107) (xy 130.013547 113.975704) (xy 130.013547 114.163745) + (xy 128.807879 112.958077) (xy 128.764967 112.854479) (xy 128.673587 112.717719) (xy 128.557281 112.601413) (xy 128.420521 112.510033) + (xy 128.26856 112.447089) (xy 128.26 112.445386) (xy 128.26 111.318072) (xy 128.65 111.318072) (xy 128.774482 111.305812) + (xy 128.89418 111.269502) (xy 129.004494 111.210537) (xy 129.101185 111.131185) (xy 129.180537 111.034494) (xy 129.239502 110.92418) + (xy 129.275812 110.804482) (xy 129.288072 110.68) (xy 129.288072 108.68) (xy 129.275812 108.555518) (xy 129.239502 108.43582) + (xy 129.180537 108.325506) (xy 129.101185 108.228815) (xy 129.004494 108.149463) (xy 128.89418 108.090498) (xy 128.774482 108.054188) + (xy 128.65 108.041928) (xy 126.856887 108.041928) (xy 126.984609 107.850779) (xy 127.104089 107.562327) (xy 127.165 107.256109) + (xy 127.165 106.943891) (xy 127.104089 106.637673) (xy 126.984609 106.349221) (xy 126.81115 106.089621) (xy 126.590379 105.86885) + (xy 126.330779 105.695391) (xy 126.042327 105.575911) (xy 125.736109 105.515) (xy 125.423891 105.515) (xy 125.117673 105.575911) + (xy 125.023303 105.615) (xy 124.85374 105.615) (xy 124.566842 105.672068) (xy 124.296589 105.78401) (xy 124.053368 105.946525) + (xy 123.846525 106.153368) (xy 123.68401 106.396589) (xy 123.572068 106.666842) (xy 123.515 106.95374) (xy 123.515 107.24626) + (xy 123.572068 107.533158) (xy 123.607988 107.619876) (xy 123.298698 107.747988) (xy 123.076252 107.896622) (xy 123.081817 107.883186) + (xy 123.185 107.364449) (xy 123.185 106.835551) (xy 123.081817 106.316814) (xy 122.879417 105.828175) (xy 122.585576 105.388412) + (xy 122.211588 105.014424) (xy 121.771825 104.720583) (xy 121.384142 104.56) (xy 122.215123 104.56) (xy 122.25 104.563435) + (xy 122.284877 104.56) (xy 122.389184 104.549727) (xy 122.52302 104.509128) (xy 122.646363 104.4432) (xy 122.754475 104.354475) + (xy 122.8432 104.246363) (xy 122.909128 104.12302) (xy 122.949727 103.989184) (xy 122.963435 103.85) (xy 122.96 103.815123) + (xy 122.96 103.613072) (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) + (xy 124.151185 103.426185) (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) + (xy 124.338072 102.686729) (xy 124.741923 102.282878) (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) + (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) + (xy 125.189967 101.104479) (xy 125.098587 100.967719) (xy 124.982281 100.851413) (xy 124.845521 100.760033) (xy 124.69356 100.697089) + (xy 124.53224 100.665) (xy 124.36776 100.665) (xy 124.335 100.671516) (xy 124.335 100.597998) (xy 124.176252 100.597998) + (xy 124.335 100.43925) (xy 124.338072 100.225) (xy 124.325812 100.100518) (xy 124.289502 99.98082) (xy 124.230537 99.870506) + (xy 124.151185 99.773815) (xy 124.054494 99.694463) (xy 123.94418 99.635498) (xy 123.824482 99.599188) (xy 123.7 99.586928) + (xy 123.18575 99.59) (xy 123.027002 99.748748) (xy 123.027002 99.59) (xy 122.96 99.59) (xy 122.96 99.439) + (xy 126.257197 99.439) (xy 128.726203 101.908008) (xy 128.749997 101.937001) (xy 128.77899 101.960795) (xy 128.778994 101.960799) + (xy 128.831241 102.003676) (xy 128.865722 102.031974) (xy 128.997751 102.102546) (xy 129.141012 102.146003) (xy 129.252665 102.157) + (xy 129.252674 102.157) (xy 129.289997 102.160676) (xy 129.326263 102.157104) (xy 129.355665 102.16) (xy 129.402843 102.16) + (xy 129.50644 102.202911) (xy 129.66776 102.235) (xy 129.83224 102.235) (xy 129.912691 102.218997) (xy 129.935498 102.29418) + (xy 129.994463 102.404494) (xy 130.073815 102.501185) (xy 130.170506 102.580537) (xy 130.28082 102.639502) (xy 130.400518 102.675812) + (xy 130.525 102.688072) (xy 131.475 102.688072) (xy 131.599482 102.675812) (xy 131.71918 102.639502) (xy 131.829494 102.580537) + (xy 131.926185 102.501185) (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) + (xy 132.113072 101.982618) (xy 132.165001 101.940001) (xy 132.188803 101.910998) (xy 134.011009 100.088794) (xy 134.040001 100.065001) + (xy 134.063795 100.036008) (xy 134.063799 100.036004) (xy 134.134973 99.949277) (xy 134.134974 99.949276) (xy 134.205546 99.817247) + (xy 134.249003 99.673986) (xy 134.249136 99.672634) (xy 134.26059 99.694063) (xy 134.343468 99.79505) (xy 135.118466 100.570049) + (xy 135.146179 100.603817) (xy 135.179947 100.63153) (xy 135.179949 100.631532) (xy 135.25983 100.697089) (xy 135.280937 100.714411) + (xy 135.434683 100.796589) (xy 135.601506 100.847195) (xy 135.731519 100.86) (xy 135.731527 100.86) (xy 135.732361 100.860082) + (xy 135.769463 100.929494) (xy 135.848815 101.026185) (xy 135.945506 101.105537) (xy 136.05582 101.164502) (xy 136.175518 101.200812) + (xy 136.3 101.213072) (xy 137.04 101.213072) (xy 137.04 101.515123) (xy 137.036565 101.55) (xy 137.050273 101.689184) + (xy 137.090872 101.82302) (xy 137.1568 101.946363) (xy 137.245525 102.054475) (xy 137.330471 102.124188) (xy 137.353637 102.1432) + (xy 137.47698 102.209128) (xy 137.610816 102.249727) (xy 137.75 102.263435) (xy 137.784877 102.26) (xy 138.374436 102.26) + (xy 138.228175 102.320583) (xy 137.788412 102.614424) (xy 137.414424 102.988412) (xy 137.120583 103.428175) (xy 136.918183 103.916814) + (xy 136.815 104.435551) (xy 136.815 104.964449) (xy 136.918183 105.483186) (xy 136.923749 105.496623) (xy 136.701302 105.347989) + (xy 136.392012 105.219877) (xy 136.427932 105.133158) (xy 136.485 104.84626) (xy 136.485 104.55374) (xy 136.427932 104.266842) + (xy 136.31599 103.996589) (xy 136.153475 103.753368) (xy 135.946632 103.546525) (xy 135.703411 103.38401) (xy 135.433158 103.272068) + (xy 135.14626 103.215) (xy 134.976697 103.215) (xy 134.882327 103.175911) (xy 134.576109 103.115) (xy 134.263891 103.115) + (xy 133.957673 103.175911) (xy 133.669221 103.295391) (xy 133.409621 103.46885) (xy 133.18885 103.689621) (xy 133.015391 103.949221) + (xy 132.895911 104.237673) (xy 132.835 104.543891) (xy 132.835 104.856109) (xy 132.895911 105.162327) (xy 133.015391 105.450779) + (xy 133.18885 105.710379) (xy 133.409621 105.93115) (xy 133.669221 106.104609) (xy 133.835016 106.173283) (xy 133.797988 106.228699) + (xy 133.637047 106.617245) (xy 133.555 107.029722) (xy 133.555 107.45028) (xy 133.637047 107.862757) (xy 133.769252 108.181928) + (xy 132.65 108.181928) (xy 132.56 108.190792) (xy 132.56 105.787323) (xy 132.563676 105.75) (xy 132.56 105.712677) + (xy 132.56 105.612667) (xy 132.549003 105.501014) (xy 132.505546 105.357753) (xy 132.434974 105.225724) (xy 132.340001 105.109999) + (xy 132.224276 105.015026) (xy 132.113072 104.955585) (xy 132.113072 104.3) (xy 132.100812 104.175518) (xy 132.064502 104.05582) + (xy 132.005537 103.945506) (xy 131.926185 103.848815) (xy 131.829494 103.769463) (xy 131.71918 103.710498) (xy 131.599482 103.674188) + (xy 131.475 103.661928) (xy 130.525 103.661928) (xy 130.400518 103.674188) (xy 130.28082 103.710498) (xy 130.170506 103.769463) + (xy 130.073815 103.848815) (xy 129.994463 103.945506) (xy 129.935498 104.05582) (xy 129.899188 104.175518) (xy 129.886928 104.3) + (xy 129.886928 105.6) (xy 129.899188 105.724482) (xy 129.935498 105.84418) (xy 129.994463 105.954494) (xy 130.073815 106.051185) + (xy 130.170506 106.130537) (xy 130.28082 106.189502) (xy 130.400518 106.225812) (xy 130.525 106.238072) (xy 131.040001 106.238072) + (xy 131.04 108.602843) (xy 130.997089 108.70644) (xy 130.965 108.86776) (xy 130.965 109.03224) (xy 130.997089 109.19356) + (xy 131.040001 109.297159) (xy 131.04 111.712679) (xy 131.036324 111.750002) (xy 131.04 111.787324) (xy 131.04 111.787334) + (xy 131.050997 111.898987) (xy 131.083592 112.00644) (xy 131.094454 112.042248) (xy 131.165026 112.174278) (xy 131.19736 112.213677) + (xy 131.259999 112.290003) (xy 131.289002 112.313805) (xy 131.961204 112.986009) (xy 131.984998 113.015002) (xy 132.013991 113.038796) + (xy 132.013995 113.0388) (xy 132.064198 113.08) (xy 132.100723 113.109975) (xy 132.232752 113.180547) (xy 132.376013 113.224004) + (xy 132.487666 113.235001) (xy 132.487675 113.235001) (xy 132.524998 113.238677) (xy 132.562321 113.235001) (xy 145.487677 113.235001) + (xy 145.524999 113.238677) (xy 145.562321 113.235001) (xy 145.562332 113.235001) (xy 145.673985 113.224004) (xy 145.817246 113.180547) + (xy 145.949275 113.109975) (xy 146.065 113.015002) (xy 146.068071 113.01126) (xy 151.565 113.01126) (xy 151.565 113.17574) + (xy 151.597089 113.33706) (xy 151.660033 113.489021) (xy 151.751413 113.625781) (xy 151.867719 113.742087) (xy 152.004479 113.833467) + (xy 152.15644 113.896411) (xy 152.31776 113.9285) (xy 152.48224 113.9285) (xy 152.64356 113.896411) (xy 152.795521 113.833467) + (xy 152.860275 113.7902) (xy 154.339043 113.7902) (xy 154.44264 113.833111) (xy 154.60396 113.8652) (xy 154.76844 113.8652) + (xy 154.92976 113.833111) (xy 155.081721 113.770167) (xy 155.218481 113.678787) (xy 155.334787 113.562481) (xy 155.426167 113.425721) + (xy 155.489111 113.27376) (xy 155.5212 113.11244) (xy 155.5212 112.94796) (xy 155.489111 112.78664) (xy 155.426167 112.634679) + (xy 155.334787 112.497919) (xy 155.218481 112.381613) (xy 155.081721 112.290233) (xy 154.92976 112.227289) (xy 154.76844 112.1952) + (xy 154.60396 112.1952) (xy 154.44264 112.227289) (xy 154.339043 112.2702) (xy 152.541059 112.2702) (xy 152.48224 112.2585) + (xy 152.31776 112.2585) (xy 152.15644 112.290589) (xy 152.004479 112.353533) (xy 151.867719 112.444913) (xy 151.751413 112.561219) + (xy 151.660033 112.697979) (xy 151.597089 112.84994) (xy 151.565 113.01126) (xy 146.068071 113.01126) (xy 146.088803 112.985999) + (xy 147.011003 112.063799) (xy 147.040001 112.040001) (xy 147.134974 111.924276) (xy 147.205546 111.792247) (xy 147.249003 111.648986) + (xy 147.26 111.537333) (xy 147.26 111.537325) (xy 147.263676 111.5) (xy 147.26 111.462675) (xy 147.26 108.918072) + (xy 147.65 108.918072) (xy 147.774482 108.905812) (xy 147.89418 108.869502) (xy 148.004494 108.810537) (xy 148.101185 108.731185) + (xy 148.180537 108.634494) (xy 148.239502 108.52418) (xy 148.275812 108.404482) (xy 148.288072 108.28) (xy 148.288072 106.28) + (xy 148.275812 106.155518) (xy 148.239502 106.03582) (xy 148.180537 105.925506) (xy 148.101185 105.828815) (xy 148.004494 105.749463) + (xy 147.89418 105.690498) (xy 147.774482 105.654188) (xy 147.65 105.641928) (xy 145.856887 105.641928) (xy 145.984609 105.450779) + (xy 146.104089 105.162327) (xy 146.165 104.856109) (xy 146.165 104.543891) (xy 146.104089 104.237673) (xy 145.984609 103.949221) + (xy 145.81115 103.689621) (xy 145.590379 103.46885) (xy 145.330779 103.295391) (xy 145.042327 103.175911) (xy 144.736109 103.115) + (xy 144.423891 103.115) (xy 144.117673 103.175911) (xy 144.023303 103.215) (xy 143.85374 103.215) (xy 143.566842 103.272068) + (xy 143.296589 103.38401) (xy 143.053368 103.546525) (xy 142.846525 103.753368) (xy 142.68401 103.996589) (xy 142.572068 104.266842) + (xy 142.515 104.55374) (xy 142.515 104.84626) (xy 142.572068 105.133158) (xy 142.607988 105.219876) (xy 142.298698 105.347988) + (xy 142.076252 105.496622) (xy 142.081817 105.483186) (xy 142.185 104.964449) (xy 142.185 104.435551) (xy 142.081817 103.916814) + (xy 141.879417 103.428175) (xy 141.585576 102.988412) (xy 141.211588 102.614424) (xy 140.771825 102.320583) (xy 140.625564 102.26) + (xy 141.215123 102.26) (xy 141.25 102.263435) (xy 141.284877 102.26) (xy 141.389184 102.249727) (xy 141.52302 102.209128) + (xy 141.646363 102.1432) (xy 141.754475 102.054475) (xy 141.8432 101.946363) (xy 141.909128 101.82302) (xy 141.949727 101.689184) + (xy 141.963435 101.55) (xy 141.96 101.515123) (xy 141.96 101.213072) (xy 142.7 101.213072) (xy 142.824482 101.200812) + (xy 142.94418 101.164502) (xy 143.054494 101.105537) (xy 143.151185 101.026185) (xy 143.230537 100.929494) (xy 143.289502 100.81918) + (xy 143.325812 100.699482) (xy 143.330979 100.647014) (xy 143.400276 100.609974) (xy 143.516001 100.515001) (xy 143.539803 100.485998) + (xy 144.111004 99.914798) (xy 144.140001 99.891001) (xy 144.234974 99.775276) (xy 144.305546 99.643247) (xy 144.349003 99.499986) + (xy 144.35886 99.39991) (xy 144.402911 99.29356) (xy 144.435 99.13224) (xy 144.435 98.96776) (xy 144.402911 98.80644) + (xy 144.339967 98.654479) (xy 144.248587 98.517719) (xy 144.132281 98.401413) (xy 143.995521 98.310033) (xy 143.84356 98.247089) + (xy 143.68224 98.215) (xy 143.51776 98.215) (xy 143.35644 98.247089) (xy 143.335 98.25597) (xy 143.335 98.197998) + (xy 143.176252 98.197998) (xy 143.335 98.03925) (xy 143.338072 97.825) (xy 143.325812 97.700518) (xy 143.289502 97.58082) + (xy 143.230537 97.470506) (xy 143.151185 97.373815) (xy 143.054494 97.294463) (xy 142.94418 97.235498) (xy 142.824482 97.199188) + (xy 142.7 97.186928) (xy 142.18575 97.19) (xy 142.027002 97.348748) (xy 142.027002 97.19) (xy 141.96 97.19) + (xy 141.96 97.084877) (xy 141.963435 97.05) (xy 141.949727 96.910816) (xy 141.909128 96.77698) (xy 141.8432 96.653637) + (xy 141.754475 96.545525) (xy 141.646363 96.4568) (xy 141.52302 96.390872) (xy 141.389184 96.350273) (xy 141.284877 96.34) + (xy 141.25 96.336565) (xy 141.215123 96.34) (xy 137.784877 96.34) (xy 137.75 96.336565) (xy 137.715123 96.34) + (xy 137.610816 96.350273) (xy 137.47698 96.390872) (xy 137.353637 96.4568) (xy 137.245525 96.545525) (xy 137.1568 96.653637) + (xy 137.090872 96.77698) (xy 137.050273 96.910816) (xy 137.036565 97.05) (xy 137.040001 97.084887) (xy 137.040001 97.186928) + (xy 136.3 97.186928) (xy 136.175518 97.199188) (xy 136.05582 97.235498) (xy 135.945506 97.294463) (xy 135.848815 97.373815) + (xy 135.769463 97.470506) (xy 135.757338 97.493189) (xy 135.670753 97.519454) (xy 135.538724 97.590026) (xy 135.422999 97.684999) + (xy 135.399196 97.714003) (xy 135.189013 97.924186) (xy 135.160009 97.947989) (xy 135.112781 98.005537) (xy 135.065036 98.063714) + (xy 135.001431 98.182709) (xy 134.994464 98.195744) (xy 134.958342 98.314826) (xy 134.82651 98.327809) (xy 134.659687 98.378416) + (xy 134.505941 98.460594) (xy 134.371183 98.571187) (xy 134.26059 98.705945) (xy 134.26 98.707049) (xy 134.26 96.614801) + (xy 135.859999 95.014804) (xy 135.860008 95.014793) (xy 135.964801 94.91) (xy 149.240001 94.91) (xy 149.240001 95.572317) + (xy 149.170506 95.609463) (xy 149.073815 95.688815) (xy 148.994463 95.785506) (xy 148.935498 95.89582) (xy 148.899188 96.015518) + (xy 148.886928 96.14) (xy 148.886928 97.44) (xy 148.899188 97.564482) (xy 148.935498 97.68418) (xy 148.994463 97.794494) + (xy 149.073815 97.891185) (xy 149.165 97.966018) (xy 149.165 98.02224) (xy 149.197089 98.18356) (xy 149.260033 98.335521) + (xy 149.351413 98.472281) (xy 149.467719 98.588587) (xy 149.604479 98.679967) (xy 149.75644 98.742911) (xy 149.91776 98.775) + (xy 150.08224 98.775) (xy 150.24356 98.742911) (xy 150.395521 98.679967) (xy 150.532281 98.588587) (xy 150.648587 98.472281) + (xy 150.739967 98.335521) (xy 150.802911 98.18356) (xy 150.835 98.02224) (xy 150.835 97.966018) (xy 150.926185 97.891185) + (xy 151.005537 97.794494) (xy 151.064502 97.68418) (xy 151.100812 97.564482) (xy 151.113072 97.44) (xy 151.113072 96.14) + (xy 151.100812 96.015518) (xy 151.064502 95.89582) (xy 151.005537 95.785506) (xy 150.926185 95.688815) (xy 150.829494 95.609463) + (xy 150.76 95.572317) (xy 150.76 94.459601) (xy 151.546402 93.6732) (xy 154.487453 93.6732) (xy 154.524775 93.676876) + (xy 154.562097 93.6732) (xy 154.562108 93.6732) (xy 154.673761 93.662203) (xy 154.817022 93.618746) (xy 154.949051 93.548174) + (xy 154.969378 93.531492) (xy 155.004479 93.554946) (xy 155.108077 93.597858) (xy 155.440001 93.929782) (xy 155.440001 94.676928) + (xy 155.4 94.676928) (xy 155.275518 94.689188) (xy 155.15582 94.725498) (xy 155.045506 94.784463) (xy 154.948815 94.863815) + (xy 154.869463 94.960506) (xy 154.810498 95.07082) (xy 154.774188 95.190518) (xy 154.761928 95.315) (xy 154.761928 95.705) + (xy 154.66776 95.705) (xy 154.50644 95.737089) (xy 154.457685 95.757284) (xy 154.378817 95.661183) (xy 154.244059 95.550589) + (xy 154.090313 95.468411) (xy 153.92349 95.417805) (xy 153.75 95.400718) (xy 153.576511 95.417805) (xy 153.409688 95.468411) + (xy 153.255942 95.550589) (xy 153.121183 95.661183) (xy 153.010589 95.795941) (xy 152.928411 95.949687) (xy 152.877805 96.11651) + (xy 152.865 96.246523) (xy 152.865 96.458533) (xy 152.860719 96.502002) (xy 152.865 96.545471) (xy 152.865 96.545478) + (xy 152.875085 96.647877) (xy 152.877805 96.675492) (xy 152.884989 96.699173) (xy 152.928411 96.842314) (xy 153.010589 96.99606) + (xy 153.121183 97.130819) (xy 153.154956 97.158536) (xy 154.156468 98.160049) (xy 154.184181 98.193817) (xy 154.217949 98.22153) + (xy 154.217951 98.221532) (xy 154.262088 98.257754) (xy 154.318939 98.304411) (xy 154.472685 98.386589) (xy 154.639508 98.437195) + (xy 154.769521 98.45) (xy 154.769531 98.45) (xy 154.812997 98.454281) (xy 154.856463 98.45) (xy 154.894499 98.45) + (xy 154.948815 98.516185) (xy 155.045506 98.595537) (xy 155.15582 98.654502) (xy 155.275518 98.690812) (xy 155.315001 98.694701) + (xy 155.315001 99.101521) (xy 155.310719 99.145) (xy 155.327805 99.31849) (xy 155.378412 99.485313) (xy 155.46059 99.639059) + (xy 155.543468 99.740046) (xy 155.543471 99.740049) (xy 155.571184 99.773817) (xy 155.604952 99.80153) (xy 155.938466 100.135044) + (xy 155.966183 100.168817) (xy 156.100941 100.279411) (xy 156.254687 100.361589) (xy 156.42151 100.412195) (xy 156.551523 100.425) + (xy 156.551533 100.425) (xy 156.566374 100.426462) (xy 156.514424 100.478412) (xy 156.220583 100.918175) (xy 156.018183 101.406814) + (xy 155.915 101.925551) (xy 155.915 102.454449) (xy 156.018183 102.973186) (xy 156.023749 102.986623) (xy 155.801302 102.837989) + (xy 155.492012 102.709877) (xy 155.527932 102.623158) (xy 155.585 102.33626) (xy 155.585 102.04374) (xy 155.527932 101.756842) + (xy 155.41599 101.486589) (xy 155.253475 101.243368) (xy 155.046632 101.036525) (xy 154.803411 100.87401) (xy 154.533158 100.762068) + (xy 154.24626 100.705) (xy 154.076697 100.705) (xy 153.982327 100.665911) (xy 153.676109 100.605) (xy 153.363891 100.605) + (xy 153.057673 100.665911) (xy 152.769221 100.785391) (xy 152.509621 100.95885) (xy 152.28885 101.179621) (xy 152.115391 101.439221) + (xy 151.995911 101.727673) (xy 151.935 102.033891) (xy 151.935 102.346109) (xy 151.995911 102.652327) (xy 152.115391 102.940779) + (xy 152.28885 103.200379) (xy 152.509621 103.42115) (xy 152.769221 103.594609) (xy 152.935016 103.663283) (xy 152.897988 103.718699) + (xy 152.737047 104.107245) (xy 152.655 104.519722) (xy 152.655 104.94028) (xy 152.737047 105.352757) (xy 152.869252 105.671928) + (xy 151.75 105.671928) (xy 151.66 105.680792) (xy 151.66 101.277322) (xy 151.663676 101.239999) (xy 151.66 101.202676) + (xy 151.66 101.202667) (xy 151.649003 101.091014) (xy 151.605546 100.947753) (xy 151.534974 100.815724) (xy 151.440001 100.699999) + (xy 151.411003 100.676201) (xy 151.113072 100.37827) (xy 151.113072 99.69) (xy 151.100812 99.565518) (xy 151.064502 99.44582) + (xy 151.005537 99.335506) (xy 150.926185 99.238815) (xy 150.829494 99.159463) (xy 150.71918 99.100498) (xy 150.599482 99.064188) + (xy 150.475 99.051928) (xy 149.525 99.051928) (xy 149.400518 99.064188) (xy 149.28082 99.100498) (xy 149.170506 99.159463) + (xy 149.073815 99.238815) (xy 148.994463 99.335506) (xy 148.935498 99.44582) (xy 148.899188 99.565518) (xy 148.886928 99.69) + (xy 148.886928 100.99) (xy 148.899188 101.114482) (xy 148.935498 101.23418) (xy 148.994463 101.344494) (xy 149.073815 101.441185) + (xy 149.170506 101.520537) (xy 149.28082 101.579502) (xy 149.400518 101.615812) (xy 149.525 101.628072) (xy 150.140001 101.628072) + (xy 150.14 106.192843) (xy 150.097089 106.29644) (xy 150.065 106.45776) (xy 150.065 106.62224) (xy 150.097089 106.78356) + (xy 150.140001 106.887159) (xy 150.14 109.302679) (xy 150.136324 109.340002) (xy 150.14 109.377324) (xy 150.14 109.377334) + (xy 150.150997 109.488987) (xy 150.179297 109.582281) (xy 150.194454 109.632248) (xy 150.265026 109.764278) (xy 150.295009 109.800812) + (xy 150.359999 109.880003) (xy 150.389002 109.903805) (xy 151.061204 110.576009) (xy 151.084998 110.605002) (xy 151.113991 110.628796) + (xy 151.113995 110.6288) (xy 151.175187 110.679018) (xy 151.200723 110.699975) (xy 151.332752 110.770547) (xy 151.476013 110.814004) + (xy 151.587666 110.825001) (xy 151.587675 110.825001) (xy 151.624998 110.828677) (xy 151.662321 110.825001) (xy 164.587677 110.825001) + (xy 164.624999 110.828677) (xy 164.662321 110.825001) (xy 164.662332 110.825001) (xy 164.773985 110.814004) (xy 164.917246 110.770547) + (xy 165.049275 110.699975) (xy 165.165 110.605002) (xy 165.188803 110.575999) (xy 166.111003 109.653799) (xy 166.140001 109.630001) + (xy 166.234974 109.514276) (xy 166.305546 109.382247) (xy 166.349003 109.238986) (xy 166.36 109.127333) (xy 166.36 109.127325) + (xy 166.363676 109.09) (xy 166.36 109.052675) (xy 166.36 106.408072) (xy 166.75 106.408072) (xy 166.874482 106.395812) + (xy 166.99418 106.359502) (xy 167.104494 106.300537) (xy 167.201185 106.221185) (xy 167.280537 106.124494) (xy 167.339502 106.01418) + (xy 167.375812 105.894482) (xy 167.388072 105.77) (xy 167.388072 103.77) (xy 167.375812 103.645518) (xy 167.339502 103.52582) + (xy 167.280537 103.415506) (xy 167.201185 103.318815) (xy 167.104494 103.239463) (xy 166.99418 103.180498) (xy 166.874482 103.144188) + (xy 166.75 103.131928) (xy 164.956887 103.131928) (xy 165.084609 102.940779) (xy 165.204089 102.652327) (xy 165.265 102.346109) + (xy 165.265 102.033891) (xy 165.204089 101.727673) (xy 165.084609 101.439221) (xy 164.91115 101.179621) (xy 164.690379 100.95885) + (xy 164.430779 100.785391) (xy 164.142327 100.665911) (xy 163.836109 100.605) (xy 163.523891 100.605) (xy 163.217673 100.665911) + (xy 163.123303 100.705) (xy 162.95374 100.705) (xy 162.666842 100.762068) (xy 162.396589 100.87401) (xy 162.153368 101.036525) + (xy 161.946525 101.243368) (xy 161.78401 101.486589) (xy 161.672068 101.756842) (xy 161.615 102.04374) (xy 161.615 102.33626) + (xy 161.672068 102.623158) (xy 161.707988 102.709876) (xy 161.398698 102.837988) (xy 161.176252 102.986622) (xy 161.181817 102.973186) + (xy 161.285 102.454449) (xy 161.285 101.925551) (xy 161.181817 101.406814) (xy 160.979417 100.918175) (xy 160.685576 100.478412) + (xy 160.632164 100.425) (xy 165.556511 100.425) (xy 165.59998 100.429281) (xy 165.643449 100.425) (xy 165.643457 100.425) + (xy 165.77347 100.412195) (xy 165.940293 100.361589) (xy 166.094039 100.279411) (xy 166.228797 100.168817) (xy 166.256514 100.135044) + (xy 167.081522 99.310037) (xy 167.1644 99.20905) (xy 167.246578 99.055304) (xy 167.297184 98.888481) (xy 167.314271 98.714991) + (xy 167.297184 98.541501) (xy 167.246578 98.374677) (xy 167.1644 98.220932) (xy 167.053807 98.086173) (xy 166.919048 97.97558) + (xy 166.765303 97.893402) (xy 166.598479 97.842796) (xy 166.424989 97.825709) (xy 166.251499 97.842796) (xy 166.084676 97.893402) + (xy 165.93093 97.97558) (xy 165.829943 98.058458) (xy 165.233402 98.655) (xy 162.042538 98.655) (xy 162.04418 98.654502) + (xy 162.154494 98.595537) (xy 162.251185 98.516185) (xy 162.330537 98.419494) (xy 162.381046 98.325) (xy 162.687678 98.325) + (xy 162.725 98.328676) (xy 162.762322 98.325) (xy 162.762333 98.325) (xy 162.873986 98.314003) (xy 163.017247 98.270546) + (xy 163.149276 98.199974) (xy 163.265001 98.105001) (xy 163.288803 98.075998) (xy 163.811004 97.553798) (xy 163.840001 97.530001) + (xy 163.934974 97.414276) (xy 164.005546 97.282247) (xy 164.049003 97.138986) (xy 164.06 97.027333) (xy 164.06 97.027325) + (xy 164.063676 96.99) (xy 164.06 96.952675) (xy 164.06 96.014134) (xy 164.063676 95.976812) (xy 164.06 95.939489) + (xy 164.06 95.939479) (xy 164.049003 95.827826) (xy 164.005546 95.684565) (xy 163.987725 95.651224) (xy 163.934974 95.552535) + (xy 163.863799 95.465809) (xy 163.840001 95.436811) (xy 163.811003 95.413013) (xy 162.576992 94.179003) (xy 162.553189 94.149999) + (xy 162.437464 94.055026) (xy 162.305435 93.984454) (xy 162.162174 93.940997) (xy 162.050521 93.93) (xy 162.05051 93.93) + (xy 162.013188 93.926324) (xy 161.975866 93.93) (xy 161.797157 93.93) (xy 161.69356 93.887089) (xy 161.53224 93.855) + (xy 161.36776 93.855) (xy 161.20644 93.887089) (xy 161.054479 93.950033) (xy 160.937873 94.027946) (xy 160.854475 93.926325) + (xy 160.746363 93.8376) (xy 160.62302 93.771672) (xy 160.489184 93.731073) (xy 160.384877 93.7208) (xy 160.35 93.717365) + (xy 160.315123 93.7208) (xy 156.96 93.7208) (xy 156.96 93.652302) (xy 156.963676 93.614979) (xy 156.96 93.577656) + (xy 156.96 93.577646) (xy 156.949003 93.465993) (xy 156.905546 93.322732) (xy 156.834974 93.190703) (xy 156.740001 93.074978) + (xy 156.711002 93.05118) (xy 156.7098 93.049977) (xy 163.935176 93.049977) (xy 165.5462 94.661002) (xy 165.57 94.690002) + (xy 165.685725 94.784975) (xy 165.817754 94.855547) (xy 165.961015 94.899004) (xy 166.072668 94.910001) (xy 166.072677 94.910001) + (xy 166.11 94.913677) (xy 166.147323 94.910001) (xy 168.490001 94.910001) (xy 168.49 98.552843) (xy 168.447089 98.65644) + (xy 168.415 98.81776) (xy 168.415 98.98224) (xy 168.447089 99.14356) (xy 168.459533 99.173602) (xy 168.420506 99.194463) + (xy 168.323815 99.273815) (xy 168.244463 99.370506) (xy 168.185498 99.48082) (xy 168.149188 99.600518) (xy 168.136928 99.725) + (xy 168.136928 101.025) (xy 168.149188 101.149482) (xy 168.185498 101.26918) (xy 168.244463 101.379494) (xy 168.323815 101.476185) + (xy 168.420506 101.555537) (xy 168.53082 101.614502) (xy 168.650518 101.650812) (xy 168.775 101.663072) (xy 169.725 101.663072) + (xy 169.849482 101.650812) (xy 169.96918 101.614502) (xy 170.079494 101.555537) (xy 170.176185 101.476185) (xy 170.255537 101.379494) + (xy 170.314502 101.26918) (xy 170.350812 101.149482) (xy 170.363072 101.025) (xy 170.363072 99.725) (xy 170.350812 99.600518) + (xy 170.314502 99.48082) (xy 170.255537 99.370506) (xy 170.176185 99.273815) (xy 170.079494 99.194463) (xy 170.040467 99.173602) + (xy 170.052911 99.14356) (xy 170.085 98.98224) (xy 170.085 98.81776) (xy 170.052911 98.65644) (xy 170.01 98.552843) + (xy 170.01 95.51) (xy 170.08224 95.51) (xy 170.24356 95.477911) (xy 170.395521 95.414967) (xy 170.402955 95.41) + (xy 181.185199 95.41) (xy 182.649602 96.874404) (xy 182.6734 96.903402) (xy 182.702398 96.9272) (xy 182.789124 96.998375) + (xy 182.857706 97.035033) (xy 182.921154 97.068947) (xy 183.064415 97.112404) (xy 183.176068 97.123401) (xy 183.176078 97.123401) + (xy 183.213401 97.127077) (xy 183.250724 97.123401) (xy 185.127842 97.123401) (xy 185.231439 97.166312) (xy 185.392759 97.198401) + (xy 185.557239 97.198401) (xy 185.718559 97.166312) (xy 185.87052 97.103368) (xy 186.00728 97.011988) (xy 186.123586 96.895682) + (xy 186.214966 96.758922) (xy 186.27791 96.606961) (xy 186.309999 96.445641) (xy 186.309999 96.281161) (xy 186.27791 96.119841) + (xy 186.214966 95.96788) (xy 186.123586 95.83112) (xy 186.00728 95.714814) (xy 185.87052 95.623434) (xy 185.718559 95.56049) + (xy 185.557239 95.528401) (xy 185.392759 95.528401) (xy 185.231439 95.56049) (xy 185.127842 95.603401) (xy 183.528203 95.603401) + (xy 183.061957 95.137155) (xy 183.101014 95.149003) (xy 183.212667 95.16) (xy 183.212676 95.16) (xy 183.249999 95.163676) + (xy 183.287322 95.16) (xy 185.652843 95.16) (xy 185.75644 95.202911) (xy 185.91776 95.235) (xy 186.08224 95.235) + (xy 186.24356 95.202911) (xy 186.395521 95.139967) (xy 186.532281 95.048587) (xy 186.648587 94.932281) (xy 186.739967 94.795521) + (xy 186.802911 94.64356) (xy 186.835 94.48224) (xy 186.835 94.31776) (xy 186.802911 94.15644) (xy 186.739967 94.004479) + (xy 186.648587 93.867719) (xy 186.532281 93.751413) (xy 186.395521 93.660033) (xy 186.24356 93.597089) (xy 186.08224 93.565) + (xy 185.91776 93.565) (xy 185.75644 93.597089) (xy 185.652843 93.64) (xy 184.534801 93.64) (xy 185.111003 93.063799) + (xy 185.140001 93.040001) (xy 185.234974 92.924276) (xy 185.305546 92.792247) (xy 185.349003 92.648986) (xy 185.36 92.537333) + (xy 185.36 92.537325) (xy 185.363676 92.5) (xy 185.36 92.462675) (xy 185.36 89.9) (xy 187.386928 89.9) + (xy 187.386928 91.2) (xy 187.399188 91.324482) (xy 187.435498 91.44418) (xy 187.494463 91.554494) (xy 187.573815 91.651185) + (xy 187.665 91.726018) (xy 187.665 91.83224) (xy 187.697089 91.99356) (xy 187.760033 92.145521) (xy 187.851413 92.282281) + (xy 187.967719 92.398587) (xy 188.104479 92.489967) (xy 188.25644 92.552911) (xy 188.41776 92.585) (xy 188.58224 92.585) + (xy 188.74356 92.552911) (xy 188.895521 92.489967) (xy 189.032281 92.398587) (xy 189.148587 92.282281) (xy 189.239967 92.145521) + (xy 189.302911 91.99356) (xy 189.335 91.83224) (xy 189.335 91.726018) (xy 189.426185 91.651185) (xy 189.505537 91.554494) + (xy 189.564502 91.44418) (xy 189.600812 91.324482) (xy 189.613072 91.2) (xy 189.613072 89.9) (xy 189.600812 89.775518) + (xy 189.564502 89.65582) (xy 189.505537 89.545506) (xy 189.426185 89.448815) (xy 189.329494 89.369463) (xy 189.21918 89.310498) + (xy 189.099482 89.274188) (xy 188.975 89.261928) (xy 188.025 89.261928) (xy 187.900518 89.274188) (xy 187.78082 89.310498) + (xy 187.670506 89.369463) (xy 187.573815 89.448815) (xy 187.494463 89.545506) (xy 187.435498 89.65582) (xy 187.399188 89.775518) + (xy 187.386928 89.9) (xy 185.36 89.9) (xy 185.36 89.818072) (xy 185.75 89.818072) (xy 185.874482 89.805812) + (xy 185.99418 89.769502) (xy 186.104494 89.710537) (xy 186.201185 89.631185) (xy 186.280537 89.534494) (xy 186.339502 89.42418) + (xy 186.375812 89.304482) (xy 186.388072 89.18) (xy 186.388072 87.18) (xy 186.375812 87.055518) (xy 186.339502 86.93582) + (xy 186.280537 86.825506) (xy 186.201185 86.728815) (xy 186.104494 86.649463) (xy 185.99418 86.590498) (xy 185.874482 86.554188) + (xy 185.75 86.541928) (xy 183.956887 86.541928) (xy 184.084609 86.350779) (xy 184.204089 86.062327) (xy 184.265 85.756109) + (xy 184.265 85.443891) (xy 184.204089 85.137673) (xy 184.084609 84.849221) (xy 183.91115 84.589621) (xy 183.690379 84.36885) + (xy 183.430779 84.195391) (xy 183.142327 84.075911) (xy 182.836109 84.015) (xy 182.523891 84.015) (xy 182.217673 84.075911) + (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) (xy 181.153368 84.446525) + (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) (xy 180.615 85.74626) + (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) (xy 180.181817 86.383186) + (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) (xy 179.685576 83.888412) + (xy 179.457164 83.66) (xy 183.789324 83.66) (xy 183.90644 83.708511) (xy 184.06776 83.7406) (xy 184.23224 83.7406) + (xy 184.39356 83.708511) (xy 184.545521 83.645567) (xy 184.682281 83.554187) (xy 184.798587 83.437881) (xy 184.889967 83.301121) + (xy 184.952911 83.14916) (xy 184.985 82.98784) (xy 184.985 82.82336) (xy 185.1946 82.82336) (xy 185.1946 82.98784) + (xy 185.226689 83.14916) (xy 185.289633 83.301121) (xy 185.381013 83.437881) (xy 185.497319 83.554187) (xy 185.634079 83.645567) + (xy 185.737678 83.688479) (xy 187.74 85.690802) (xy 187.74 85.782317) (xy 187.670506 85.819463) (xy 187.573815 85.898815) + (xy 187.494463 85.995506) (xy 187.435498 86.10582) (xy 187.399188 86.225518) (xy 187.386928 86.35) (xy 187.386928 87.65) + (xy 187.399188 87.774482) (xy 187.435498 87.89418) (xy 187.494463 88.004494) (xy 187.573815 88.101185) (xy 187.665 88.176018) + (xy 187.665 88.33224) (xy 187.697089 88.49356) (xy 187.760033 88.645521) (xy 187.851413 88.782281) (xy 187.967719 88.898587) + (xy 188.104479 88.989967) (xy 188.25644 89.052911) (xy 188.41776 89.085) (xy 188.58224 89.085) (xy 188.74356 89.052911) + (xy 188.895521 88.989967) (xy 189.032281 88.898587) (xy 189.148587 88.782281) (xy 189.239967 88.645521) (xy 189.302911 88.49356) + (xy 189.335 88.33224) (xy 189.335 88.176018) (xy 189.426185 88.101185) (xy 189.505537 88.004494) (xy 189.564502 87.89418) + (xy 189.600812 87.774482) (xy 189.613072 87.65) (xy 189.613072 86.35) (xy 189.600812 86.225518) (xy 189.564502 86.10582) + (xy 189.505537 85.995506) (xy 189.426185 85.898815) (xy 189.329494 85.819463) (xy 189.26 85.782317) (xy 189.26 85.413322) + (xy 189.263676 85.375999) (xy 189.26 85.338676) (xy 189.26 85.338667) (xy 189.249003 85.227014) (xy 189.205546 85.083753) + (xy 189.134974 84.951724) (xy 189.040001 84.835999) (xy 189.011004 84.812202) (xy 186.812479 82.613678) (xy 186.769567 82.510079) + (xy 186.678187 82.373319) (xy 186.561881 82.257013) (xy 186.425121 82.165633) (xy 186.27316 82.102689) (xy 186.11184 82.0706) + (xy 185.94736 82.0706) (xy 185.78604 82.102689) (xy 185.634079 82.165633) (xy 185.497319 82.257013) (xy 185.381013 82.373319) + (xy 185.289633 82.510079) (xy 185.226689 82.66204) (xy 185.1946 82.82336) (xy 184.985 82.82336) (xy 184.952911 82.66204) + (xy 184.889967 82.510079) (xy 184.798587 82.373319) (xy 184.682281 82.257013) (xy 184.545521 82.165633) (xy 184.39356 82.102689) + (xy 184.23224 82.0706) (xy 184.06776 82.0706) (xy 183.90644 82.102689) (xy 183.816363 82.14) (xy 180.06 82.14) + (xy 180.06 82.113072) (xy 180.8 82.113072) (xy 180.924482 82.100812) (xy 181.04418 82.064502) (xy 181.154494 82.005537) + (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) (xy 181.425812 81.599482) (xy 181.431418 81.542562) + (xy 181.465001 81.515001) (xy 181.488803 81.485998) (xy 181.891923 81.082878) (xy 181.995521 81.039967) (xy 182.132281 80.948587) + (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) (xy 182.435 80.21776) + (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) (xy 181.995521 79.560033) + (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.51776 79.465) (xy 181.410571 79.486321) (xy 181.27625 79.352) + (xy 180.127 79.352) (xy 180.127 79.372) (xy 180.06 79.372) (xy 180.06 79.078) (xy 180.127 79.078) + (xy 180.127 79.098) (xy 181.27625 79.098) (xy 181.435 78.93925) (xy 181.438072 78.725) (xy 181.425812 78.600518) + (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) (xy 181.154494 78.194463) (xy 181.04418 78.135498) + (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.28575 78.09) (xy 180.127002 78.248748) (xy 180.127002 78.09) + (xy 180.06 78.09) (xy 180.06 77.984877) (xy 180.063435 77.95) (xy 180.049727 77.810816) (xy 180.009128 77.67698) + (xy 179.9432 77.553637) (xy 179.854475 77.445525) (xy 179.746363 77.3568) (xy 179.62302 77.290872) (xy 179.489184 77.250273) + (xy 179.384877 77.24) (xy 179.35 77.236565) (xy 179.315123 77.24) (xy 175.884877 77.24) (xy 175.85 77.236565) + (xy 175.815123 77.24) (xy 175.710816 77.250273) (xy 175.57698 77.290872) (xy 175.453637 77.3568) (xy 175.345525 77.445525) + (xy 175.2568 77.553637) (xy 175.190872 77.67698) (xy 175.150273 77.810816) (xy 175.136565 77.95) (xy 175.140001 77.984887) + (xy 175.140001 78.086928) (xy 174.4 78.086928) (xy 174.275518 78.099188) (xy 174.15582 78.135498) (xy 174.045506 78.194463) + (xy 173.948815 78.273815) (xy 173.869463 78.370506) (xy 173.810498 78.48082) (xy 173.806686 78.493387) (xy 173.720753 78.519454) + (xy 173.588724 78.590026) (xy 173.472999 78.684999) (xy 173.4492 78.713998) (xy 172.989002 79.174197) (xy 172.959999 79.197999) + (xy 172.916164 79.251413) (xy 172.865026 79.313724) (xy 172.80849 79.419494) (xy 172.794454 79.445754) (xy 172.750997 79.589015) + (xy 172.74 79.700668) (xy 172.74 79.700678) (xy 172.736324 79.738) (xy 172.74 79.775322) (xy 172.74 80.002841) + (xy 172.697089 80.106438) (xy 172.665 80.267758) (xy 172.665 80.432238) (xy 172.673412 80.474526) (xy 172.605941 80.510589) + (xy 172.471183 80.621183) (xy 172.360589 80.755941) (xy 172.278411 80.909687) (xy 172.269919 80.937681) (xy 172.148986 80.900997) + (xy 172.037333 80.89) (xy 172.037322 80.89) (xy 172 80.886324) (xy 171.962678 80.89) (xy 170.827238 80.89) + (xy 170.825812 80.875518) (xy 170.789502 80.75582) (xy 170.730537 80.645506) (xy 170.651185 80.548815) (xy 170.554494 80.469463) + (xy 170.44418 80.410498) (xy 170.324482 80.374188) (xy 170.2 80.361928) (xy 169.25 80.361928) (xy 169.125518 80.374188) + (xy 169.00582 80.410498) (xy 168.895506 80.469463) (xy 168.798815 80.548815) (xy 168.719463 80.645506) (xy 168.660498 80.75582) + (xy 168.624188 80.875518) (xy 168.611928 81) (xy 168.611928 82.3) (xy 168.624188 82.424482) (xy 168.660498 82.54418) + (xy 168.719463 82.654494) (xy 168.798815 82.751185) (xy 168.895506 82.830537) (xy 169.00582 82.889502) (xy 169.125518 82.925812) + (xy 169.25 82.938072) (xy 170.2 82.938072) (xy 170.324482 82.925812) (xy 170.44418 82.889502) (xy 170.554494 82.830537) + (xy 170.651185 82.751185) (xy 170.730537 82.654494) (xy 170.789502 82.54418) (xy 170.825812 82.424482) (xy 170.827238 82.41) + (xy 171.685199 82.41) (xy 172.6862 83.411002) (xy 172.709999 83.440001) (xy 172.738997 83.463799) (xy 172.825723 83.534974) + (xy 172.914151 83.58224) (xy 172.957753 83.605546) (xy 173.101014 83.649003) (xy 173.212667 83.66) (xy 173.212677 83.66) + (xy 173.25 83.663676) (xy 173.287323 83.66) (xy 174.445386 83.66) (xy 174.447089 83.66856) (xy 174.510033 83.820521) + (xy 174.601413 83.957281) (xy 174.717719 84.073587) (xy 174.854479 84.164967) (xy 175.00644 84.227911) (xy 175.16776 84.26) + (xy 175.266136 84.26) (xy 175.220583 84.328175) (xy 175.018183 84.816814) (xy 174.915 85.335551) (xy 174.915 85.864449) + (xy 175.018183 86.383186) (xy 175.023749 86.396623) (xy 174.801302 86.247989) (xy 174.492012 86.119877) (xy 174.527932 86.033158) + (xy 174.585 85.74626) (xy 174.585 85.45374) (xy 174.527932 85.166842) (xy 174.41599 84.896589) (xy 174.253475 84.653368) + (xy 174.046632 84.446525) (xy 173.803411 84.28401) (xy 173.533158 84.172068) (xy 173.24626 84.115) (xy 173.076697 84.115) + (xy 172.982327 84.075911) (xy 172.676109 84.015) (xy 172.363891 84.015) (xy 172.057673 84.075911) (xy 171.769221 84.195391) + (xy 171.509621 84.36885) (xy 171.28885 84.589621) (xy 171.115391 84.849221) (xy 170.995911 85.137673) (xy 170.935 85.443891) + (xy 170.935 85.756109) (xy 170.995911 86.062327) (xy 171.115391 86.350779) (xy 171.28885 86.610379) (xy 171.509621 86.83115) + (xy 171.769221 87.004609) (xy 171.935016 87.073283) (xy 171.897988 87.128699) (xy 171.737047 87.517245) (xy 171.655 87.929722) + (xy 171.655 88.35028) (xy 171.737047 88.762757) (xy 171.869252 89.081928) (xy 170.75 89.081928) (xy 170.625518 89.094188) + (xy 170.50582 89.130498) (xy 170.395506 89.189463) (xy 170.336818 89.237627) (xy 170.295521 89.210033) (xy 170.14356 89.147089) + (xy 169.98224 89.115) (xy 169.81776 89.115) (xy 169.65644 89.147089) (xy 169.504479 89.210033) (xy 169.367719 89.301413) + (xy 169.251413 89.417719) (xy 169.160033 89.554479) (xy 169.097089 89.70644) (xy 169.065 89.86776) (xy 169.065 90.03224) + (xy 169.097089 90.19356) (xy 169.140001 90.297159) (xy 169.14 92.712679) (xy 169.136324 92.750002) (xy 169.14 92.787324) + (xy 169.14 92.787334) (xy 169.149912 92.887967) (xy 169.145521 92.885033) (xy 168.99356 92.822089) (xy 168.83224 92.79) + (xy 168.66776 92.79) (xy 168.50644 92.822089) (xy 168.402843 92.865) (xy 166.599802 92.865) (xy 165.249801 91.515) + (xy 166.011003 90.753799) (xy 166.040001 90.730001) (xy 166.134974 90.614276) (xy 166.205546 90.482247) (xy 166.249003 90.338986) + (xy 166.26 90.227333) (xy 166.26 90.227325) (xy 166.263676 90.19) (xy 166.26 90.152675) (xy 166.26 87.408072) + (xy 166.440001 87.408072) (xy 166.440001 91.758477) (xy 166.452806 91.88849) (xy 166.503412 92.055313) (xy 166.58559 92.209059) + (xy 166.696184 92.343817) (xy 166.830942 92.454411) (xy 166.984688 92.536589) (xy 167.151511 92.587195) (xy 167.325 92.604282) + (xy 167.49849 92.587195) (xy 167.665313 92.536589) (xy 167.819059 92.454411) (xy 167.953817 92.343817) (xy 168.064411 92.209059) + (xy 168.146589 92.055313) (xy 168.197195 91.88849) (xy 168.21 91.758477) (xy 168.21 84.55) (xy 168.611928 84.55) + (xy 168.611928 85.85) (xy 168.624188 85.974482) (xy 168.660498 86.09418) (xy 168.719463 86.204494) (xy 168.798815 86.301185) + (xy 168.895506 86.380537) (xy 168.946789 86.407949) (xy 168.915 86.56776) (xy 168.915 86.73224) (xy 168.947089 86.89356) + (xy 169.010033 87.045521) (xy 169.101413 87.182281) (xy 169.217719 87.298587) (xy 169.354479 87.389967) (xy 169.50644 87.452911) + (xy 169.66776 87.485) (xy 169.83224 87.485) (xy 169.99356 87.452911) (xy 170.145521 87.389967) (xy 170.282281 87.298587) + (xy 170.398587 87.182281) (xy 170.489967 87.045521) (xy 170.552911 86.89356) (xy 170.585 86.73224) (xy 170.585 86.56776) + (xy 170.552911 86.40644) (xy 170.544414 86.385925) (xy 170.554494 86.380537) (xy 170.651185 86.301185) (xy 170.730537 86.204494) + (xy 170.789502 86.09418) (xy 170.825812 85.974482) (xy 170.838072 85.85) (xy 170.838072 84.55) (xy 170.825812 84.425518) + (xy 170.789502 84.30582) (xy 170.730537 84.195506) (xy 170.651185 84.098815) (xy 170.554494 84.019463) (xy 170.44418 83.960498) + (xy 170.324482 83.924188) (xy 170.2 83.911928) (xy 169.25 83.911928) (xy 169.125518 83.924188) (xy 169.00582 83.960498) + (xy 168.895506 84.019463) (xy 168.798815 84.098815) (xy 168.719463 84.195506) (xy 168.660498 84.30582) (xy 168.624188 84.425518) + (xy 168.611928 84.55) (xy 168.21 84.55) (xy 168.21 78.158466) (xy 168.214281 78.114999) (xy 168.21 78.071533) + (xy 168.21 78.071523) (xy 168.197195 77.94151) (xy 168.146589 77.774687) (xy 168.135 77.753005) (xy 168.135 65.463078) + (xy 168.386928 65.21115) (xy 168.386928 66.075) (xy 168.399188 66.199482) (xy 168.435498 66.31918) (xy 168.494463 66.429494) + (xy 168.573815 66.526185) (xy 168.670506 66.605537) (xy 168.78082 66.664502) (xy 168.900518 66.700812) (xy 169.025 66.713072) + (xy 169.708204 66.713072) (xy 169.747533 66.808021) (xy 169.838913 66.944781) (xy 169.955219 67.061087) (xy 170.091979 67.152467) + (xy 170.24394 67.215411) (xy 170.40526 67.2475) (xy 170.56974 67.2475) (xy 170.73106 67.215411) (xy 170.883021 67.152467) + (xy 171.019781 67.061087) (xy 171.031828 67.04904) (xy 171.115391 67.250779) (xy 171.28885 67.510379) (xy 171.509621 67.73115) + (xy 171.769221 67.904609) (xy 171.935016 67.973283) (xy 171.897988 68.028699) (xy 171.737047 68.417245) (xy 171.655 68.829722) + (xy 171.655 69.25028) (xy 171.737047 69.662757) (xy 171.869252 69.981928) (xy 170.75 69.981928) (xy 170.625518 69.994188) + (xy 170.50582 70.030498) (xy 170.395506 70.089463) (xy 170.336818 70.137627) (xy 170.295521 70.110033) (xy 170.14356 70.047089) + (xy 169.98224 70.015) (xy 169.81776 70.015) (xy 169.65644 70.047089) (xy 169.504479 70.110033) (xy 169.367719 70.201413) + (xy 169.251413 70.317719) (xy 169.160033 70.454479) (xy 169.097089 70.60644) (xy 169.065 70.76776) (xy 169.065 70.93224) + (xy 169.097089 71.09356) (xy 169.140001 71.197159) (xy 169.14 73.612679) (xy 169.136324 73.650002) (xy 169.14 73.687324) + (xy 169.14 73.687334) (xy 169.150997 73.798987) (xy 169.182907 73.904181) (xy 169.194454 73.942248) (xy 169.265026 74.074278) + (xy 169.297792 74.114203) (xy 169.359999 74.190003) (xy 169.389002 74.213805) (xy 170.061204 74.886009) (xy 170.084998 74.915002) + (xy 170.113991 74.938796) (xy 170.113995 74.9388) (xy 170.170259 74.984974) (xy 170.200723 75.009975) (xy 170.332752 75.080547) + (xy 170.476013 75.124004) (xy 170.587666 75.135001) (xy 170.587675 75.135001) (xy 170.624998 75.138677) (xy 170.662321 75.135001) + (xy 183.587677 75.135001) (xy 183.624999 75.138677) (xy 183.662321 75.135001) (xy 183.662332 75.135001) (xy 183.773985 75.124004) + (xy 183.917246 75.080547) (xy 184.049275 75.009975) (xy 184.165 74.915002) (xy 184.188803 74.885999) (xy 185.111003 73.963799) + (xy 185.140001 73.940001) (xy 185.234974 73.824276) (xy 185.305546 73.692247) (xy 185.349003 73.548986) (xy 185.36 73.437333) + (xy 185.36 73.437325) (xy 185.363676 73.4) (xy 185.36 73.362675) (xy 185.36 70.718072) (xy 185.75 70.718072) + (xy 185.874482 70.705812) (xy 185.99418 70.669502) (xy 186.104494 70.610537) (xy 186.201185 70.531185) (xy 186.280537 70.434494) + (xy 186.339502 70.32418) (xy 186.375812 70.204482) (xy 186.388072 70.08) (xy 186.388072 68.08) (xy 186.375812 67.955518) + (xy 186.339502 67.83582) (xy 186.280537 67.725506) (xy 186.201185 67.628815) (xy 186.104494 67.549463) (xy 185.99418 67.490498) + (xy 185.874482 67.454188) (xy 185.75 67.441928) (xy 183.956887 67.441928) (xy 184.084609 67.250779) (xy 184.204089 66.962327) + (xy 184.265 66.656109) (xy 184.265 66.343891) (xy 184.204089 66.037673) (xy 184.084609 65.749221) (xy 183.91115 65.489621) + (xy 183.876199 65.45467) (xy 183.898587 65.432281) (xy 183.989967 65.295521) (xy 184.052911 65.14356) (xy 184.085 64.98224) + (xy 184.085 64.81776) (xy 184.052911 64.65644) (xy 183.989967 64.504479) (xy 183.898587 64.367719) (xy 183.782281 64.251413) + (xy 183.710011 64.203124) (xy 183.710011 61.47883) (xy 183.752922 61.375233) (xy 183.785011 61.213913) (xy 183.785011 61.049433) + (xy 183.752922 60.888113) (xy 183.689978 60.736152) (xy 183.598598 60.599392) (xy 183.482292 60.483086) (xy 183.345532 60.391706) + (xy 183.193571 60.328762) (xy 183.032251 60.296673) (xy 182.867771 60.296673) (xy 182.706451 60.328762) (xy 182.55449 60.391706) + (xy 182.41773 60.483086) (xy 182.301424 60.599392) (xy 182.260586 60.66051) (xy 182.198585 60.567719) (xy 182.082279 60.451413) + (xy 181.945519 60.360033) (xy 181.793558 60.297089) (xy 181.632238 60.265) (xy 181.467758 60.265) (xy 181.318867 60.294617) + (xy 181.27625 60.252) (xy 180.127 60.252) (xy 180.127 60.272) (xy 180.06 60.272) (xy 180.06 59.978) + (xy 180.127 59.978) (xy 180.127 59.998) (xy 181.27625 59.998) (xy 181.435 59.83925) (xy 181.438072 59.625) + (xy 181.425812 59.500518) (xy 181.389502 59.38082) (xy 181.330537 59.270506) (xy 181.251185 59.173815) (xy 181.154494 59.094463) + (xy 181.04418 59.035498) (xy 180.924482 58.999188) (xy 180.8 58.986928) (xy 180.28575 58.99) (xy 180.127002 59.148748) + (xy 180.127002 58.99) (xy 180.06 58.99) (xy 180.06 58.783277) (xy 180.063435 58.7484) (xy 180.049727 58.609216) + (xy 180.009128 58.47538) (xy 179.9432 58.352037) (xy 179.854475 58.243925) (xy 179.746363 58.1552) (xy 179.62302 58.089272) + (xy 179.489184 58.048673) (xy 179.384877 58.0384) (xy 179.35 58.034965) (xy 179.315123 58.0384) (xy 175.884877 58.0384) + (xy 175.85 58.034965) (xy 175.815123 58.0384) (xy 175.710816 58.048673) (xy 175.57698 58.089272) (xy 175.453637 58.1552) + (xy 175.345525 58.243925) (xy 175.2568 58.352037) (xy 175.190872 58.47538) (xy 175.150273 58.609216) (xy 175.136565 58.7484) + (xy 175.140001 58.783287) (xy 175.140001 58.986928) (xy 174.4 58.986928) (xy 174.275518 58.999188) (xy 174.15582 59.035498) + (xy 174.045506 59.094463) (xy 173.948815 59.173815) (xy 173.869463 59.270506) (xy 173.810498 59.38082) (xy 173.774188 59.500518) + (xy 173.761928 59.625) (xy 173.761928 59.91327) (xy 173.322722 60.352476) (xy 173.304479 60.360033) (xy 173.167719 60.451413) + (xy 173.051413 60.567719) (xy 172.960033 60.704479) (xy 172.897089 60.85644) (xy 172.870522 60.99) (xy 172.310001 60.99) + (xy 172.310001 60.47047) (xy 172.314282 60.427001) (xy 172.310001 60.383532) (xy 172.310001 60.383524) (xy 172.297196 60.253511) + (xy 172.24659 60.086688) (xy 172.164412 59.932942) (xy 172.122145 59.88144) (xy 172.081533 59.831954) (xy 172.081531 59.831952) + (xy 172.053818 59.798184) (xy 172.020051 59.770472) (xy 168.635 56.385422) (xy 168.635 53.833477) (xy 168.639282 53.79) + (xy 168.635 53.746523) (xy 168.635 48.471105) (xy 168.650518 48.475812) (xy 168.775 48.488072) (xy 169.725 48.488072) + (xy 169.849482 48.475812) (xy 169.934399 48.450053) (xy 169.934399 51.015) (xy 169.81776 51.015) (xy 169.65644 51.047089) + (xy 169.504479 51.110033) (xy 169.367719 51.201413) (xy 169.251413 51.317719) (xy 169.160033 51.454479) (xy 169.097089 51.60644) + (xy 169.065 51.76776) (xy 169.065 51.93224) (xy 169.097089 52.09356) (xy 169.140001 52.197159) (xy 169.14 54.612679) + (xy 169.136324 54.650002) (xy 169.14 54.687324) (xy 169.14 54.687334) (xy 169.150997 54.798987) (xy 169.184976 54.911003) + (xy 169.194454 54.942248) (xy 169.265026 55.074278) (xy 169.304871 55.122828) (xy 169.359999 55.190003) (xy 169.389002 55.213805) + (xy 170.061204 55.886009) (xy 170.084998 55.915002) (xy 170.113991 55.938796) (xy 170.113995 55.9388) (xy 170.175729 55.989463) + (xy 170.200723 56.009975) (xy 170.332752 56.080547) (xy 170.476013 56.124004) (xy 170.587666 56.135001) (xy 170.587675 56.135001) + (xy 170.624998 56.138677) (xy 170.662321 56.135001) (xy 183.587677 56.135001) (xy 183.624999 56.138677) (xy 183.662321 56.135001) + (xy 183.662332 56.135001) (xy 183.773985 56.124004) (xy 183.917246 56.080547) (xy 184.049275 56.009975) (xy 184.165 55.915002) + (xy 184.188803 55.885999) (xy 185.111004 54.963798) (xy 185.140001 54.940001) (xy 185.234974 54.824276) (xy 185.305546 54.692247) + (xy 185.349003 54.548986) (xy 185.36 54.437333) (xy 185.36 54.437325) (xy 185.363676 54.4) (xy 185.36 54.362675) + (xy 185.36 51.718072) (xy 185.75 51.718072) (xy 185.874482 51.705812) (xy 185.99418 51.669502) (xy 186.104494 51.610537) + (xy 186.201185 51.531185) (xy 186.280537 51.434494) (xy 186.339502 51.32418) (xy 186.375812 51.204482) (xy 186.388072 51.08) + (xy 186.388072 49.08) (xy 186.375812 48.955518) (xy 186.339502 48.83582) (xy 186.280537 48.725506) (xy 186.201185 48.628815) + (xy 186.104494 48.549463) (xy 185.99418 48.490498) (xy 185.874482 48.454188) (xy 185.75 48.441928) (xy 183.956887 48.441928) + (xy 184.084609 48.250779) (xy 184.204089 47.962327) (xy 184.265 47.656109) (xy 184.265 47.343891) (xy 184.204089 47.037673) + (xy 184.084609 46.749221) (xy 183.91115 46.489621) (xy 183.690379 46.26885) (xy 183.430779 46.095391) (xy 183.142327 45.975911) + (xy 182.836109 45.915) (xy 182.523891 45.915) (xy 182.217673 45.975911) (xy 182.123303 46.015) (xy 181.95374 46.015) + (xy 181.666842 46.072068) (xy 181.396589 46.18401) (xy 181.153368 46.346525) (xy 180.946525 46.553368) (xy 180.78401 46.796589) + (xy 180.672068 47.066842) (xy 180.615 47.35374) (xy 180.615 47.64626) (xy 180.672068 47.933158) (xy 180.707988 48.019876) + (xy 180.398698 48.147988) (xy 180.176252 48.296622) (xy 180.181817 48.283186) (xy 180.285 47.764449) (xy 180.285 47.235551) + (xy 180.181817 46.716814) (xy 179.979417 46.228175) (xy 179.685576 45.788412) (xy 179.657164 45.76) (xy 179.812677 45.76) + (xy 179.849999 45.763676) (xy 179.887321 45.76) (xy 179.887332 45.76) (xy 179.998985 45.749003) (xy 180.142246 45.705546) + (xy 180.274275 45.634974) (xy 180.39 45.540001) (xy 180.413803 45.510997) (xy 180.541922 45.382878) (xy 180.645521 45.339966) + (xy 180.782281 45.248586) (xy 180.898587 45.13228) (xy 180.989967 44.99552) (xy 181.052911 44.843559) (xy 181.085 44.682239) + (xy 181.085 44.517759) (xy 181.052911 44.356439) (xy 181.01 44.252842) (xy 181.01 43.97487) (xy 181.04418 43.964502) + (xy 181.154494 43.905537) (xy 181.251185 43.826185) (xy 181.330537 43.729494) (xy 181.389502 43.61918) (xy 181.425812 43.499482) + (xy 181.438072 43.375) (xy 181.438072 42.375) (xy 181.425812 42.250518) (xy 181.389502 42.13082) (xy 181.330537 42.020506) + (xy 181.313708 42) (xy 181.330537 41.979494) (xy 181.389502 41.86918) (xy 181.425812 41.749482) (xy 181.438072 41.625) + (xy 181.435 41.41075) (xy 181.27625 41.252) (xy 180.127 41.252) (xy 180.127 41.272) (xy 180.06 41.272) + (xy 180.06 40.978) (xy 180.127 40.978) (xy 180.127 40.998) (xy 181.27625 40.998) (xy 181.435 40.83925) + (xy 181.436495 40.735) (xy 181.58224 40.735) (xy 181.74356 40.702911) (xy 181.895521 40.639967) (xy 182.032281 40.548587) + (xy 182.148587 40.432281) (xy 182.239967 40.295521) (xy 182.302911 40.14356) (xy 182.335 39.98224) (xy 182.335 39.81776) + (xy 182.302911 39.65644) (xy 182.239967 39.504479) (xy 182.148587 39.367719) (xy 182.032281 39.251413) (xy 181.895521 39.160033) + (xy 181.791922 39.117121) (xy 181.634801 38.96) (xy 188.535199 38.96) + ) + ) + (filled_polygon + (pts + (xy 101.570506 122.594463) (xy 101.473815 122.673815) (xy 101.394463 122.770506) (xy 101.335498 122.88082) (xy 101.299188 123.000518) + (xy 101.286928 123.125) (xy 101.286928 123.813271) (xy 100.883078 124.217121) (xy 100.779479 124.260033) (xy 100.642719 124.351413) + (xy 100.526413 124.467719) (xy 100.435033 124.604479) (xy 100.372089 124.75644) (xy 100.34 124.91776) (xy 100.34 125.08224) + (xy 100.372089 125.24356) (xy 100.435033 125.395521) (xy 100.526413 125.532281) (xy 100.642719 125.648587) (xy 100.779479 125.739967) + (xy 100.93144 125.802911) (xy 101.09276 125.835) (xy 101.25724 125.835) (xy 101.41856 125.802911) (xy 101.570521 125.739967) + (xy 101.707281 125.648587) (xy 101.823587 125.532281) (xy 101.914967 125.395521) (xy 101.957879 125.291922) (xy 102.064895 125.184907) + (xy 102.000033 125.281979) (xy 101.937089 125.43394) (xy 101.905 125.59526) (xy 101.905 125.75974) (xy 101.937089 125.92106) + (xy 102.000033 126.073021) (xy 102.091413 126.209781) (xy 102.207719 126.326087) (xy 102.339015 126.413816) (xy 102.784536 126.859338) + (xy 101.607306 126.859338) (xy 101.543653 126.770509) (xy 101.452359 126.685003) (xy 101.346137 126.61895) (xy 101.22907 126.574889) + (xy 101.105657 126.554513) (xy 100.98064 126.558606) (xy 100.858824 126.587009) (xy 100.744889 126.638632) (xy 100.659567 126.687893) + (xy 100.446477 126.474803) (xy 100.422674 126.445799) (xy 100.306949 126.350826) (xy 100.17492 126.280254) (xy 100.031659 126.236797) + (xy 99.920006 126.2258) (xy 99.919995 126.2258) (xy 99.882673 126.222124) (xy 99.845351 126.2258) (xy 98.856357 126.2258) + (xy 98.75276 126.182889) (xy 98.59144 126.1508) (xy 98.42696 126.1508) (xy 98.26564 126.182889) (xy 98.113679 126.245833) + (xy 97.976919 126.337213) (xy 97.860613 126.453519) (xy 97.769233 126.590279) (xy 97.706289 126.74224) (xy 97.6742 126.90356) + (xy 97.6742 127.06804) (xy 97.706289 127.22936) (xy 97.769233 127.381321) (xy 97.860613 127.518081) (xy 97.953124 127.610592) + (xy 97.894454 127.720353) (xy 97.850997 127.863614) (xy 97.84 127.975267) (xy 97.84 127.975278) (xy 97.836324 128.0126) + (xy 97.84 128.049922) (xy 97.84 128.05635) (xy 97.836324 128.093672) (xy 97.84 128.130994) (xy 97.84 128.131004) + (xy 97.850997 128.242657) (xy 97.879174 128.335546) (xy 97.894454 128.385918) (xy 97.965026 128.517948) (xy 97.998154 128.558314) + (xy 98.048775 128.619996) (xy 98.049741 128.649504) (xy 98.078144 128.771321) (xy 98.129768 128.885255) (xy 98.509144 129.542354) + (xy 98.294489 129.666285) (xy 98.262569 129.680748) (xy 98.234084 129.70116) (xy 98.234082 129.701161) (xy 98.148886 129.762211) + (xy 98.05328 129.864289) (xy 97.979426 129.983056) (xy 97.930161 130.11395) (xy 97.907379 130.25194) (xy 97.911955 130.391721) + (xy 97.943713 130.527926) (xy 98.001434 130.655317) (xy 98.021847 130.683803) (xy 98.363544 131.27564) (xy 97.981825 131.020583) + (xy 97.493186 130.818183) (xy 96.974449 130.715) (xy 96.445551 130.715) (xy 95.926814 130.818183) (xy 95.438175 131.020583) + (xy 94.998412 131.314424) (xy 94.740295 131.572541) (xy 94.740295 131.160165) (xy 94.702229 130.968796) (xy 94.893158 130.930818) + (xy 95.163411 130.818876) (xy 95.406632 130.656361) (xy 95.613475 130.449518) (xy 95.77599 130.206297) (xy 95.887932 129.936044) + (xy 95.945 129.649146) (xy 95.945 129.356626) (xy 95.887932 129.069728) (xy 95.77599 128.799475) (xy 95.733355 128.735668) + (xy 95.694089 128.538264) (xy 95.574609 128.249812) (xy 95.40115 127.990212) (xy 95.180379 127.769441) (xy 94.920779 127.595982) + (xy 94.632327 127.476502) (xy 94.326109 127.415591) (xy 94.108815 127.415591) (xy 97.736928 123.787478) (xy 97.736928 124.075) + (xy 97.749188 124.199482) (xy 97.785498 124.31918) (xy 97.844463 124.429494) (xy 97.923815 124.526185) (xy 98.020506 124.605537) + (xy 98.13082 124.664502) (xy 98.250518 124.700812) (xy 98.375 124.713072) (xy 99.675 124.713072) (xy 99.799482 124.700812) + (xy 99.91918 124.664502) (xy 100.029494 124.605537) (xy 100.126185 124.526185) (xy 100.205537 124.429494) (xy 100.264502 124.31918) + (xy 100.300812 124.199482) (xy 100.313072 124.075) (xy 100.313072 123.56173) (xy 100.491923 123.382878) (xy 100.595521 123.339967) + (xy 100.732281 123.248587) (xy 100.848587 123.132281) (xy 100.939967 122.995521) (xy 101.002911 122.84356) (xy 101.035 122.68224) + (xy 101.035 122.584799) (xy 101.588586 122.584799) + ) + ) + (filled_polygon + (pts + (xy 151.995911 121.752327) (xy 152.115391 122.040779) (xy 152.28885 122.300379) (xy 152.509621 122.52115) (xy 152.769221 122.694609) + (xy 152.935016 122.763283) (xy 152.897988 122.818699) (xy 152.737047 123.207245) (xy 152.655 123.619722) (xy 152.655 124.04028) + (xy 152.737047 124.452757) (xy 152.869252 124.771928) (xy 151.75 124.771928) (xy 151.625518 124.784188) (xy 151.50582 124.820498) + (xy 151.395506 124.879463) (xy 151.298815 124.958815) (xy 151.219463 125.055506) (xy 151.160498 125.16582) (xy 151.124188 125.285518) + (xy 151.111928 125.41) (xy 151.111928 127.41) (xy 151.124188 127.534482) (xy 151.160498 127.65418) (xy 151.219463 127.764494) + (xy 151.298815 127.861185) (xy 151.395506 127.940537) (xy 151.50582 127.999502) (xy 151.625518 128.035812) (xy 151.75 128.048072) + (xy 153.46327 128.048072) (xy 153.484188 128.06899) (xy 147.040831 128.06899) (xy 147.063795 128.041008) (xy 147.063799 128.041004) + (xy 147.134973 127.954277) (xy 147.134974 127.954276) (xy 147.154326 127.918072) (xy 147.65 127.918072) (xy 147.774482 127.905812) + (xy 147.89418 127.869502) (xy 148.004494 127.810537) (xy 148.101185 127.731185) (xy 148.180537 127.634494) (xy 148.239502 127.52418) + (xy 148.275812 127.404482) (xy 148.288072 127.28) (xy 148.288072 125.28) (xy 148.275812 125.155518) (xy 148.239502 125.03582) + (xy 148.180537 124.925506) (xy 148.101185 124.828815) (xy 148.004494 124.749463) (xy 147.89418 124.690498) (xy 147.774482 124.654188) + (xy 147.65 124.641928) (xy 145.856887 124.641928) (xy 145.984609 124.450779) (xy 146.104089 124.162327) (xy 146.165 123.856109) + (xy 146.165 123.543891) (xy 146.104089 123.237673) (xy 145.984609 122.949221) (xy 145.939361 122.881502) (xy 147.999843 122.881502) + (xy 148.10344 122.924413) (xy 148.26476 122.956502) (xy 148.42924 122.956502) (xy 148.59056 122.924413) (xy 148.742521 122.861469) + (xy 148.879281 122.770089) (xy 148.995587 122.653783) (xy 149.086967 122.517023) (xy 149.149911 122.365062) (xy 149.174231 122.2428) + (xy 151.024091 122.2428) (xy 151.061413 122.246476) (xy 151.098735 122.2428) (xy 151.098746 122.2428) (xy 151.210399 122.231803) + (xy 151.35366 122.188346) (xy 151.485689 122.117774) (xy 151.601414 122.022801) (xy 151.625217 121.993797) (xy 151.974471 121.644543) + ) + ) + (filled_polygon + (pts + (xy 104.3544 122.70704) (xy 104.386489 122.86836) (xy 104.449433 123.020321) (xy 104.540813 123.157081) (xy 104.657119 123.273387) + (xy 104.793879 123.364767) (xy 104.94584 123.427711) (xy 105.09781 123.45794) (xy 105.015 123.54075) (xy 105.011928 123.755) + (xy 105.024188 123.879482) (xy 105.060498 123.99918) (xy 105.119463 124.109494) (xy 105.136292 124.13) (xy 105.119463 124.150506) + (xy 105.060498 124.26082) (xy 105.024188 124.380518) (xy 105.011928 124.505) (xy 105.011928 125.505) (xy 105.017601 125.562598) + (xy 104.940199 125.64) (xy 103.714802 125.64) (xy 103.551396 125.476594) (xy 103.542911 125.43394) (xy 103.479967 125.281979) + (xy 103.388587 125.145219) (xy 103.272281 125.028913) (xy 103.135521 124.937533) (xy 102.98356 124.874589) (xy 102.82224 124.8425) + (xy 102.65776 124.8425) (xy 102.49644 124.874589) (xy 102.344479 124.937533) (xy 102.247407 125.002394) (xy 102.53673 124.713072) + (xy 103.225 124.713072) (xy 103.349482 124.700812) (xy 103.46918 124.664502) (xy 103.579494 124.605537) (xy 103.676185 124.526185) + (xy 103.755537 124.429494) (xy 103.814502 124.31918) (xy 103.850812 124.199482) (xy 103.863072 124.075) (xy 103.863072 123.125) + (xy 103.850812 123.000518) (xy 103.814502 122.88082) (xy 103.755537 122.770506) (xy 103.676185 122.673815) (xy 103.579494 122.594463) + (xy 103.561414 122.584799) (xy 104.3544 122.584799) + ) + ) + (filled_polygon + (pts + (xy 107.361728 121.0998) (xy 107.373988 121.224282) (xy 107.410298 121.34398) (xy 107.469263 121.454294) (xy 107.548615 121.550985) + (xy 107.645306 121.630337) (xy 107.75562 121.689302) (xy 107.875318 121.725612) (xy 107.9998 121.737872) (xy 109.2998 121.737872) + (xy 109.424282 121.725612) (xy 109.54398 121.689302) (xy 109.654294 121.630337) (xy 109.699999 121.592828) (xy 109.699998 122.222062) + (xy 109.695506 122.224463) (xy 109.598815 122.303815) (xy 109.519463 122.400506) (xy 109.460498 122.51082) (xy 109.424188 122.630518) + (xy 109.411928 122.755) (xy 109.411928 123.030002) (xy 109.108077 123.333853) (xy 109.004479 123.376765) (xy 108.867719 123.468145) + (xy 108.839569 123.496295) (xy 108.68224 123.465) (xy 108.51776 123.465) (xy 108.35644 123.497089) (xy 108.275051 123.530801) + (xy 108.12625 123.382) (xy 106.777 123.382) (xy 106.777 123.402) (xy 106.523 123.402) (xy 106.523 123.382) + (xy 106.503 123.382) (xy 106.503 123.128) (xy 106.523 123.128) (xy 106.523 122.27875) (xy 106.777 122.27875) + (xy 106.777 123.128) (xy 108.12625 123.128) (xy 108.285 122.96925) (xy 108.288072 122.755) (xy 108.275812 122.630518) + (xy 108.239502 122.51082) (xy 108.180537 122.400506) (xy 108.101185 122.303815) (xy 108.004494 122.224463) (xy 107.89418 122.165498) + (xy 107.774482 122.129188) (xy 107.65 122.116928) (xy 106.93575 122.12) (xy 106.777 122.27875) (xy 106.523 122.27875) + (xy 106.36425 122.12) (xy 105.956555 122.118246) (xy 107.361728 120.713074) + ) + ) + (filled_polygon + (pts + (xy 142.027 117.198) (xy 142.047 117.198) (xy 142.047 117.452) (xy 142.027 117.452) (xy 142.027 117.472) + (xy 141.9604 117.472) (xy 141.9604 117.178) (xy 142.027 117.178) + ) + ) + (filled_polygon + (pts + (xy 161.127 114.788) (xy 161.147 114.788) (xy 161.147 115.042) (xy 161.127 115.042) (xy 161.127 115.062) + (xy 161.0604 115.062) (xy 161.0604 114.768) (xy 161.127 114.768) + ) + ) + (filled_polygon + (pts + (xy 115.554951 99.743471) (xy 115.521184 99.771183) (xy 115.493471 99.804951) (xy 115.493468 99.804954) (xy 115.41059 99.905941) + (xy 115.328412 100.059687) (xy 115.277805 100.22651) (xy 115.260719 100.4) (xy 115.265001 100.443479) (xy 115.265 101.78153) + (xy 115.260719 101.825) (xy 115.265 101.868469) (xy 115.265 101.868476) (xy 115.271749 101.937) (xy 115.277805 101.99849) + (xy 115.287962 102.031973) (xy 115.328411 102.165312) (xy 115.410589 102.319058) (xy 115.521183 102.453817) (xy 115.554956 102.481534) + (xy 116.14347 103.070049) (xy 116.171183 103.103817) (xy 116.204951 103.13153) (xy 116.204953 103.131532) (xy 116.284834 103.197089) + (xy 116.305941 103.214411) (xy 116.459687 103.296589) (xy 116.62651 103.347195) (xy 116.756523 103.36) (xy 116.756531 103.36) + (xy 116.797837 103.364068) (xy 116.848815 103.426185) (xy 116.945506 103.505537) (xy 117.05582 103.564502) (xy 117.175518 103.600812) + (xy 117.3 103.613072) (xy 118.04 103.613072) (xy 118.04 103.815123) (xy 118.036565 103.85) (xy 118.050273 103.989184) + (xy 118.090872 104.12302) (xy 118.1568 104.246363) (xy 118.245525 104.354475) (xy 118.330578 104.424276) (xy 118.353637 104.4432) + (xy 118.47698 104.509128) (xy 118.610816 104.549727) (xy 118.75 104.563435) (xy 118.784877 104.56) (xy 119.615858 104.56) + (xy 119.228175 104.720583) (xy 118.788412 105.014424) (xy 118.414424 105.388412) (xy 118.120583 105.828175) (xy 117.918183 106.316814) + (xy 117.815 106.835551) (xy 117.815 107.364449) (xy 117.918183 107.883186) (xy 117.923749 107.896623) (xy 117.701302 107.747989) + (xy 117.392012 107.619877) (xy 117.427932 107.533158) (xy 117.485 107.24626) (xy 117.485 106.95374) (xy 117.427932 106.666842) + (xy 117.31599 106.396589) (xy 117.153475 106.153368) (xy 116.946632 105.946525) (xy 116.703411 105.78401) (xy 116.433158 105.672068) + (xy 116.14626 105.615) (xy 115.976697 105.615) (xy 115.882327 105.575911) (xy 115.576109 105.515) (xy 115.263891 105.515) + (xy 114.957673 105.575911) (xy 114.669221 105.695391) (xy 114.409621 105.86885) (xy 114.18885 106.089621) (xy 114.015391 106.349221) + (xy 113.895911 106.637673) (xy 113.835 106.943891) (xy 113.835 107.256109) (xy 113.895911 107.562327) (xy 114.015391 107.850779) + (xy 114.18885 108.110379) (xy 114.409621 108.33115) (xy 114.669221 108.504609) (xy 114.835016 108.573283) (xy 114.797988 108.628699) + (xy 114.637047 109.017245) (xy 114.555 109.429722) (xy 114.555 109.85028) (xy 114.637047 110.262757) (xy 114.769252 110.581928) + (xy 113.65 110.581928) (xy 113.56 110.590792) (xy 113.56 105.362323) (xy 113.563676 105.325) (xy 113.56 105.287677) + (xy 113.56 105.287667) (xy 113.549003 105.176014) (xy 113.505546 105.032753) (xy 113.434974 104.900724) (xy 113.340001 104.784999) + (xy 113.311002 104.761201) (xy 113.113072 104.56327) (xy 113.113072 103.875) (xy 113.100812 103.750518) (xy 113.064502 103.63082) + (xy 113.005537 103.520506) (xy 112.926185 103.423815) (xy 112.832137 103.346632) (xy 112.835 103.33224) (xy 112.835 103.16776) + (xy 112.802911 103.00644) (xy 112.739967 102.854479) (xy 112.670156 102.75) (xy 112.739967 102.645521) (xy 112.802911 102.49356) + (xy 112.835 102.33224) (xy 112.835 102.16776) (xy 112.832137 102.153368) (xy 112.926185 102.076185) (xy 113.005537 101.979494) + (xy 113.064502 101.86918) (xy 113.100812 101.749482) (xy 113.113072 101.625) (xy 113.113072 100.711729) (xy 114.385802 99.439) + (xy 115.859422 99.439) + ) + ) + (filled_polygon + (pts + (xy 202.288997 104.363799) (xy 202.289002 104.363803) (xy 202.84 104.914802) (xy 202.840001 108.318472) (xy 202.790379 108.26885) + (xy 202.530779 108.095391) (xy 202.242327 107.975911) (xy 201.936109 107.915) (xy 201.623891 107.915) (xy 201.317673 107.975911) + (xy 201.223303 108.015) (xy 201.05374 108.015) (xy 200.766842 108.072068) (xy 200.496589 108.18401) (xy 200.253368 108.346525) + (xy 200.046525 108.553368) (xy 199.88401 108.796589) (xy 199.772068 109.066842) (xy 199.715 109.35374) (xy 199.715 109.64626) + (xy 199.772068 109.933158) (xy 199.807988 110.019876) (xy 199.498698 110.147988) (xy 199.276252 110.296622) (xy 199.281817 110.283186) + (xy 199.385 109.764449) (xy 199.385 109.235551) (xy 199.281817 108.716814) (xy 199.079417 108.228175) (xy 198.798349 107.807527) + (xy 198.898585 107.707291) (xy 198.989965 107.570531) (xy 199.032877 107.466933) (xy 199.611003 106.888807) (xy 199.640001 106.865009) + (xy 199.734974 106.749284) (xy 199.805546 106.617255) (xy 199.849003 106.473994) (xy 199.86 106.362341) (xy 199.86 106.362332) + (xy 199.863676 106.325009) (xy 199.86 106.287686) (xy 199.86 106.013072) (xy 199.9 106.013072) (xy 200.024482 106.000812) + (xy 200.14418 105.964502) (xy 200.254494 105.905537) (xy 200.351185 105.826185) (xy 200.430537 105.729494) (xy 200.489502 105.61918) + (xy 200.497824 105.591746) (xy 200.534747 105.580546) (xy 200.666776 105.509974) (xy 200.782501 105.415001) (xy 200.806303 105.385998) + (xy 201.261003 104.931298) (xy 201.290001 104.907501) (xy 201.384974 104.791776) (xy 201.455546 104.659747) (xy 201.499003 104.516486) + (xy 201.51 104.404833) (xy 201.51 104.404824) (xy 201.513676 104.367501) (xy 201.51 104.330178) (xy 201.51 104.097157) + (xy 201.552911 103.99356) (xy 201.585 103.83224) (xy 201.585 103.66776) (xy 201.583024 103.657825) + ) + ) + (filled_polygon + (pts + (xy 218.277 102.998) (xy 218.297 102.998) (xy 218.297 103.252) (xy 218.277 103.252) (xy 218.277 103.272) + (xy 218.21 103.272) (xy 218.21 102.978) (xy 218.277 102.978) + ) + ) + (filled_polygon + (pts + (xy 199.227 102.998) (xy 199.247 102.998) (xy 199.247 103.252) (xy 199.227 103.252) (xy 199.227 103.272) + (xy 199.16 103.272) (xy 199.16 102.978) (xy 199.227 102.978) + ) + ) + (filled_polygon + (pts + (xy 200.512457 101.935124) (xy 200.512457 102.235135) (xy 200.508781 102.272457) (xy 200.512457 102.309779) (xy 200.512457 102.30979) + (xy 200.523454 102.421443) (xy 200.566911 102.564704) (xy 200.637483 102.696733) (xy 200.732456 102.812458) (xy 200.761458 102.836259) + (xy 200.842175 102.916976) (xy 200.83224 102.915) (xy 200.66776 102.915) (xy 200.50644 102.947089) (xy 200.383534 102.997998) + (xy 200.376252 102.997998) (xy 200.535 102.83925) (xy 200.538072 102.625) (xy 200.525812 102.500518) (xy 200.489502 102.38082) + (xy 200.430537 102.270506) (xy 200.351185 102.173815) (xy 200.254494 102.094463) (xy 200.14418 102.035498) (xy 200.024482 101.999188) + (xy 199.9 101.986928) (xy 199.38575 101.99) (xy 199.227002 102.148748) (xy 199.227002 101.99) (xy 199.16 101.99) + (xy 199.16 101.784877) (xy 199.163435 101.75) (xy 199.149727 101.610816) (xy 199.109128 101.47698) (xy 199.0432 101.353637) + (xy 198.954475 101.245525) (xy 198.846363 101.1568) (xy 198.72302 101.090872) (xy 198.589184 101.050273) (xy 198.484877 101.04) + (xy 198.45 101.036565) (xy 198.415123 101.04) (xy 195.06 101.04) (xy 195.06 100.464799) (xy 196.691925 98.832876) + (xy 196.795521 98.789965) (xy 196.932281 98.698585) (xy 197.048587 98.582279) (xy 197.139967 98.445519) (xy 197.202911 98.293558) + (xy 197.216976 98.22285) (xy 200.512458 98.22285) + ) + ) + (filled_polygon + (pts + (xy 123.027 100.598) (xy 123.047 100.598) (xy 123.047 100.852) (xy 123.027 100.852) (xy 123.027 100.872) + (xy 122.96 100.872) (xy 122.96 100.578) (xy 123.027 100.578) + ) + ) + (filled_polygon + (pts + (xy 129.315026 90.774276) (xy 129.356655 90.825) (xy 129.41 90.890001) (xy 129.438998 90.913799) (xy 132.636211 94.111013) + (xy 132.660009 94.140011) (xy 132.775734 94.234984) (xy 132.907763 94.305556) (xy 133.051024 94.349013) (xy 133.162677 94.36001) + (xy 133.162686 94.36001) (xy 133.200009 94.363686) (xy 133.237332 94.36001) (xy 134.365187 94.36001) (xy 132.988998 95.736201) + (xy 132.96 95.759999) (xy 132.936202 95.788997) (xy 132.936201 95.788998) (xy 132.865026 95.875724) (xy 132.794454 96.007754) + (xy 132.766245 96.10075) (xy 132.750998 96.151014) (xy 132.743581 96.226324) (xy 132.736324 96.3) (xy 132.737085 96.307727) + (xy 132.645273 96.086072) (xy 132.318601 95.597174) (xy 131.902826 95.181399) (xy 131.413928 94.854727) (xy 130.870692 94.629712) + (xy 130.293997 94.515) (xy 129.706003 94.515) (xy 129.129308 94.629712) (xy 128.586072 94.854727) (xy 128.097174 95.181399) + (xy 127.681399 95.597174) (xy 127.354727 96.086072) (xy 127.129712 96.629308) (xy 127.015 97.206003) (xy 127.015 97.793997) + (xy 127.07809 98.111171) (xy 126.996274 98.044026) (xy 126.864245 97.973454) (xy 126.720984 97.929997) (xy 126.609331 97.919) + (xy 126.60932 97.919) (xy 126.571998 97.915324) (xy 126.534676 97.919) (xy 114.108322 97.919) (xy 114.070999 97.915324) + (xy 114.033676 97.919) (xy 114.033667 97.919) (xy 113.922014 97.929997) (xy 113.778753 97.973454) (xy 113.646724 98.044026) + (xy 113.530999 98.138999) (xy 113.507201 98.167997) (xy 112.76 98.915198) (xy 112.76 98.512333) (xy 112.763676 98.47501) + (xy 112.76 98.437687) (xy 112.76 98.437678) (xy 112.749003 98.326025) (xy 112.705546 98.182764) (xy 112.634974 98.050735) + (xy 112.584536 97.989276) (xy 112.563799 97.964007) (xy 112.563795 97.964003) (xy 112.540001 97.93501) (xy 112.511008 97.911216) + (xy 112.132879 97.533089) (xy 112.089968 97.429491) (xy 111.998588 97.292731) (xy 111.882282 97.176425) (xy 111.745522 97.085045) + (xy 111.593561 97.022101) (xy 111.585 97.020398) (xy 111.585 91.585) (xy 112.090199 91.585) (xy 112.487165 91.981967) + (xy 112.401413 92.067719) (xy 112.310033 92.204479) (xy 112.247089 92.35644) (xy 112.215 92.51776) (xy 112.215 92.68224) + (xy 112.247089 92.84356) (xy 112.290001 92.947159) (xy 112.29 94.216677) (xy 112.286324 94.254) (xy 112.29 94.291322) + (xy 112.29 94.291332) (xy 112.300997 94.402985) (xy 112.334574 94.513676) (xy 112.344454 94.546246) (xy 112.415026 94.678276) + (xy 112.441719 94.710801) (xy 112.509999 94.794001) (xy 112.539003 94.817804) (xy 114.357202 96.636004) (xy 114.381 96.665002) + (xy 114.409998 96.6888) (xy 114.496724 96.759975) (xy 114.598289 96.814263) (xy 114.628754 96.830547) (xy 114.772015 96.874004) + (xy 114.883668 96.885001) (xy 114.883678 96.885001) (xy 114.921001 96.888677) (xy 114.958323 96.885001) (xy 125.960677 96.885001) + (xy 125.997999 96.888677) (xy 126.035321 96.885001) (xy 126.035332 96.885001) (xy 126.146985 96.874004) (xy 126.290246 96.830547) + (xy 126.422275 96.759975) (xy 126.538 96.665002) (xy 126.561803 96.635998) (xy 128.261003 94.936799) (xy 128.290001 94.913001) + (xy 128.384974 94.797276) (xy 128.455546 94.665247) (xy 128.499003 94.521986) (xy 128.51 94.410333) (xy 128.513677 94.373) + (xy 128.51 94.335667) (xy 128.51 92.318072) (xy 128.65 92.318072) (xy 128.774482 92.305812) (xy 128.89418 92.269502) + (xy 129.004494 92.210537) (xy 129.101185 92.131185) (xy 129.180537 92.034494) (xy 129.239502 91.92418) (xy 129.275812 91.804482) + (xy 129.288072 91.68) (xy 129.288072 90.723849) + ) + ) + (filled_polygon + (pts + (xy 142.027 98.198) (xy 142.047 98.198) (xy 142.047 98.452) (xy 142.027 98.452) (xy 142.027 98.472) + (xy 141.96 98.472) (xy 141.96 98.178) (xy 142.027 98.178) + ) + ) + (filled_polygon + (pts + (xy 180.127 98.198) (xy 180.147 98.198) (xy 180.147 98.452) (xy 180.127 98.452) (xy 180.127 98.472) + (xy 180.06 98.472) (xy 180.06 98.178) (xy 180.127 98.178) + ) + ) + (filled_polygon + (pts + (xy 161.127 95.688) (xy 161.147 95.688) (xy 161.147 95.942) (xy 161.127 95.942) (xy 161.127 95.962) + (xy 161.06 95.962) (xy 161.06 95.668) (xy 161.127 95.668) + ) + ) + (filled_polygon + (pts + (xy 149.435498 40.37082) (xy 149.399188 40.490518) (xy 149.386928 40.615) (xy 149.386928 41.915) (xy 149.399188 42.039482) + (xy 149.435498 42.15918) (xy 149.494463 42.269494) (xy 149.573815 42.366185) (xy 149.670506 42.445537) (xy 149.695689 42.458998) + (xy 149.697093 42.466056) (xy 149.760037 42.618017) (xy 149.851417 42.754777) (xy 149.967723 42.871083) (xy 150.104483 42.962463) + (xy 150.256444 43.025407) (xy 150.417764 43.057496) (xy 150.582244 43.057496) (xy 150.743564 43.025407) (xy 150.895525 42.962463) + (xy 151.032285 42.871083) (xy 151.148591 42.754777) (xy 151.239971 42.618017) (xy 151.239981 42.617993) (xy 151.239981 43.586616) + (xy 151.21918 43.575498) (xy 151.099482 43.539188) (xy 150.975 43.526928) (xy 150.025 43.526928) (xy 149.900518 43.539188) + (xy 149.78082 43.575498) (xy 149.670506 43.634463) (xy 149.573815 43.713815) (xy 149.494463 43.810506) (xy 149.435498 43.92082) + (xy 149.399188 44.040518) (xy 149.386928 44.165) (xy 149.386928 45.465) (xy 149.399188 45.589482) (xy 149.435498 45.70918) + (xy 149.494463 45.819494) (xy 149.573815 45.916185) (xy 149.670506 45.995537) (xy 149.78082 46.054502) (xy 149.900518 46.090812) + (xy 150.025 46.103072) (xy 150.642612 46.103072) (xy 150.713913 46.209781) (xy 150.830219 46.326087) (xy 150.966979 46.417467) + (xy 151.11894 46.480411) (xy 151.23998 46.504488) (xy 151.23998 47.932657) (xy 151.236304 47.96998) (xy 151.23998 48.007302) + (xy 151.23998 48.007312) (xy 151.250977 48.118965) (xy 151.285871 48.233997) (xy 151.294434 48.262226) (xy 151.365006 48.394256) + (xy 151.389419 48.424003) (xy 151.459979 48.509981) (xy 151.488982 48.533783) (xy 151.492706 48.537507) (xy 151.395506 48.589463) + (xy 151.298815 48.668815) (xy 151.219463 48.765506) (xy 151.160498 48.87582) (xy 151.124188 48.995518) (xy 151.120799 49.029931) + (xy 151.082281 48.991413) (xy 150.945521 48.900033) (xy 150.79356 48.837089) (xy 150.63224 48.805) (xy 150.46776 48.805) + (xy 150.30644 48.837089) (xy 150.154479 48.900033) (xy 150.017719 48.991413) (xy 149.901413 49.107719) (xy 149.810033 49.244479) + (xy 149.747089 49.39644) (xy 149.715 49.55776) (xy 149.715 49.72224) (xy 149.747089 49.88356) (xy 149.810033 50.035521) + (xy 149.901413 50.172281) (xy 150.017719 50.288587) (xy 150.154479 50.379967) (xy 150.30644 50.442911) (xy 150.46776 50.475) + (xy 150.63224 50.475) (xy 150.79356 50.442911) (xy 150.945521 50.379967) (xy 151.082281 50.288587) (xy 151.111928 50.25894) + (xy 151.111928 50.32827) (xy 149.958078 51.482121) (xy 149.854479 51.525033) (xy 149.717719 51.616413) (xy 149.601413 51.732719) + (xy 149.510033 51.869479) (xy 149.447089 52.02144) (xy 149.415 52.18276) (xy 149.415 52.34724) (xy 149.447089 52.50856) + (xy 149.510033 52.660521) (xy 149.601413 52.797281) (xy 149.717719 52.913587) (xy 149.854479 53.004967) (xy 150.00644 53.067911) + (xy 150.16776 53.1) (xy 150.33224 53.1) (xy 150.49356 53.067911) (xy 150.645521 53.004967) (xy 150.782281 52.913587) + (xy 150.898587 52.797281) (xy 150.989967 52.660521) (xy 151.032879 52.556922) (xy 151.831729 51.758072) (xy 154.05 51.758072) + (xy 154.174482 51.745812) (xy 154.29418 51.709502) (xy 154.404494 51.650537) (xy 154.501185 51.571185) (xy 154.515002 51.554348) + (xy 154.699017 51.738363) (xy 154.933014 51.894715) (xy 154.848815 51.963815) (xy 154.769463 52.060506) (xy 154.710498 52.17082) + (xy 154.674188 52.290518) (xy 154.661928 52.415) (xy 154.665 52.62925) (xy 154.82375 52.788) (xy 156.173 52.788) + (xy 156.173 52.768) (xy 156.427 52.768) (xy 156.427 52.788) (xy 156.447 52.788) (xy 156.447 53.042) + (xy 156.427 53.042) (xy 156.427 53.062) (xy 156.173 53.062) (xy 156.173 53.042) (xy 154.876128 53.042) + (xy 154.74356 52.987089) (xy 154.58224 52.955) (xy 154.41776 52.955) (xy 154.25644 52.987089) (xy 154.152843 53.03) + (xy 151.537333 53.03) (xy 151.5 53.026323) (xy 151.462667 53.03) (xy 151.351014 53.040997) (xy 151.207753 53.084454) + (xy 151.075724 53.155026) (xy 150.959999 53.249999) (xy 150.936201 53.278997) (xy 149.095906 55.119293) (xy 149.00644 55.137089) + (xy 148.854479 55.200033) (xy 148.717719 55.291413) (xy 148.601413 55.407719) (xy 148.510033 55.544479) (xy 148.447089 55.69644) + (xy 148.415 55.85776) (xy 148.415 56.02224) (xy 148.447089 56.18356) (xy 148.510033 56.335521) (xy 148.601413 56.472281) + (xy 148.717719 56.588587) (xy 148.732475 56.598447) (xy 148.825724 56.674974) (xy 148.957754 56.745546) (xy 149.101015 56.789002) + (xy 149.25 56.803676) (xy 149.398985 56.789002) (xy 149.542246 56.745546) (xy 149.674276 56.674974) (xy 149.761002 56.603799) + (xy 149.763997 56.600804) (xy 149.782281 56.588587) (xy 149.898587 56.472281) (xy 149.910804 56.453997) (xy 151.814802 54.55) + (xy 153.807418 54.55) (xy 153.865026 54.657776) (xy 153.96 54.773501) (xy 153.988998 54.797299) (xy 154.376196 55.184497) + (xy 154.399999 55.213501) (xy 154.467608 55.268986) (xy 154.515723 55.308474) (xy 154.629529 55.369305) (xy 154.647753 55.379046) + (xy 154.706789 55.396954) (xy 154.710498 55.40918) (xy 154.769463 55.519494) (xy 154.848815 55.616185) (xy 154.945506 55.695537) + (xy 155.05582 55.754502) (xy 155.175518 55.790812) (xy 155.3 55.803072) (xy 155.5317 55.803072) (xy 155.494454 55.872754) + (xy 155.469507 55.954997) (xy 155.450998 56.016014) (xy 155.444642 56.080546) (xy 155.436324 56.165) (xy 155.440001 56.202332) + (xy 155.440001 56.576928) (xy 155.4 56.576928) (xy 155.275518 56.589188) (xy 155.15582 56.625498) (xy 155.045506 56.684463) + (xy 154.948815 56.763815) (xy 154.869463 56.860506) (xy 154.810498 56.97082) (xy 154.774188 57.090518) (xy 154.761928 57.215) + (xy 154.761928 57.70327) (xy 154.458077 58.007121) (xy 154.354479 58.050033) (xy 154.217719 58.141413) (xy 154.101413 58.257719) + (xy 154.010033 58.394479) (xy 153.947089 58.54644) (xy 153.915 58.70776) (xy 153.915 58.87224) (xy 153.947089 59.03356) + (xy 154.010033 59.185521) (xy 154.087284 59.301135) (xy 153.443467 59.944953) (xy 153.360589 60.04594) (xy 153.278411 60.199686) + (xy 153.268188 60.233386) (xy 152.282879 59.248078) (xy 152.239967 59.144479) (xy 152.148587 59.007719) (xy 152.032281 58.891413) + (xy 151.895521 58.800033) (xy 151.797867 58.759583) (xy 151.790001 58.749999) (xy 151.674276 58.655026) (xy 151.542247 58.584454) + (xy 151.398986 58.540997) (xy 151.352874 58.536455) (xy 151.350812 58.515518) (xy 151.314502 58.39582) (xy 151.255537 58.285506) + (xy 151.176185 58.188815) (xy 151.079494 58.109463) (xy 150.96918 58.050498) (xy 150.849482 58.014188) (xy 150.725 58.001928) + (xy 149.775 58.001928) (xy 149.650518 58.014188) (xy 149.53082 58.050498) (xy 149.420506 58.109463) (xy 149.323815 58.188815) + (xy 149.244463 58.285506) (xy 149.185498 58.39582) (xy 149.149188 58.515518) (xy 149.136928 58.64) (xy 149.136928 59.94) + (xy 149.149188 60.064482) (xy 149.185498 60.18418) (xy 149.244463 60.294494) (xy 149.323815 60.391185) (xy 149.420506 60.470537) + (xy 149.53082 60.529502) (xy 149.650518 60.565812) (xy 149.775 60.578072) (xy 150.725 60.578072) (xy 150.849482 60.565812) + (xy 150.96918 60.529502) (xy 151.079494 60.470537) (xy 151.176185 60.391185) (xy 151.22135 60.336151) (xy 152.8642 61.979002) + (xy 152.887999 62.008001) (xy 153.003724 62.102974) (xy 153.135753 62.173546) (xy 153.279014 62.217003) (xy 153.390667 62.228) + (xy 153.390675 62.228) (xy 153.428 62.231676) (xy 153.465325 62.228) (xy 156.664836 62.228) (xy 156.514424 62.378412) + (xy 156.220583 62.818175) (xy 156.018183 63.306814) (xy 155.915 63.825551) (xy 155.915 64.354449) (xy 156.018183 64.873186) + (xy 156.023749 64.886623) (xy 155.801302 64.737989) (xy 155.492012 64.609877) (xy 155.527932 64.523158) (xy 155.585 64.23626) + (xy 155.585 63.94374) (xy 155.527932 63.656842) (xy 155.41599 63.386589) (xy 155.253475 63.143368) (xy 155.046632 62.936525) + (xy 154.803411 62.77401) (xy 154.533158 62.662068) (xy 154.24626 62.605) (xy 154.076697 62.605) (xy 153.982327 62.565911) + (xy 153.676109 62.505) (xy 153.363891 62.505) (xy 153.057673 62.565911) (xy 152.769221 62.685391) (xy 152.509621 62.85885) + (xy 152.37967 62.988802) (xy 152.282281 62.891413) (xy 152.145521 62.800033) (xy 151.99356 62.737089) (xy 151.83224 62.705) + (xy 151.66776 62.705) (xy 151.50644 62.737089) (xy 151.363072 62.796474) (xy 151.363072 62.19) (xy 151.350812 62.065518) + (xy 151.314502 61.94582) (xy 151.255537 61.835506) (xy 151.176185 61.738815) (xy 151.079494 61.659463) (xy 151.077778 61.658546) + (xy 151.085 61.62224) (xy 151.085 61.45776) (xy 151.052911 61.29644) (xy 150.989967 61.144479) (xy 150.898587 61.007719) + (xy 150.782281 60.891413) (xy 150.645521 60.800033) (xy 150.49356 60.737089) (xy 150.33224 60.705) (xy 150.16776 60.705) + (xy 150.00644 60.737089) (xy 149.854479 60.800033) (xy 149.717719 60.891413) (xy 149.601413 61.007719) (xy 149.510033 61.144479) + (xy 149.447089 61.29644) (xy 149.415 61.45776) (xy 149.415 61.62224) (xy 149.422222 61.658546) (xy 149.420506 61.659463) + (xy 149.323815 61.738815) (xy 149.244463 61.835506) (xy 149.185498 61.94582) (xy 149.149188 62.065518) (xy 149.136928 62.19) + (xy 149.136928 63.49) (xy 149.149188 63.614482) (xy 149.185498 63.73418) (xy 149.244463 63.844494) (xy 149.323815 63.941185) + (xy 149.420506 64.020537) (xy 149.53082 64.079502) (xy 149.650518 64.115812) (xy 149.775 64.128072) (xy 150.725 64.128072) + (xy 150.849482 64.115812) (xy 150.96918 64.079502) (xy 150.990001 64.068373) (xy 150.99 67.606544) (xy 150.98224 67.605) + (xy 150.81776 67.605) (xy 150.65644 67.637089) (xy 150.504479 67.700033) (xy 150.367719 67.791413) (xy 150.251413 67.907719) + (xy 150.160033 68.044479) (xy 150.097089 68.19644) (xy 150.065 68.35776) (xy 150.065 68.52224) (xy 150.097089 68.68356) + (xy 150.140001 68.787159) (xy 150.14 71.202679) (xy 150.136324 71.240002) (xy 150.14 71.277324) (xy 150.14 71.277334) + (xy 150.150997 71.388987) (xy 150.191046 71.521014) (xy 150.194454 71.532248) (xy 150.265026 71.664278) (xy 150.293859 71.699411) + (xy 150.359999 71.780003) (xy 150.389002 71.803805) (xy 151.061204 72.476009) (xy 151.084998 72.505002) (xy 151.113991 72.528796) + (xy 151.113995 72.5288) (xy 151.129161 72.541246) (xy 151.200723 72.599975) (xy 151.332752 72.670547) (xy 151.476013 72.714004) + (xy 151.587666 72.725001) (xy 151.587675 72.725001) (xy 151.624998 72.728677) (xy 151.662321 72.725001) (xy 164.587677 72.725001) + (xy 164.624999 72.728677) (xy 164.662321 72.725001) (xy 164.662332 72.725001) (xy 164.773985 72.714004) (xy 164.917246 72.670547) + (xy 165.049275 72.599975) (xy 165.165 72.505002) (xy 165.188803 72.475999) (xy 166.111003 71.553799) (xy 166.140001 71.530001) + (xy 166.234974 71.414276) (xy 166.305546 71.282247) (xy 166.349003 71.138986) (xy 166.36 71.027333) (xy 166.36 71.027325) + (xy 166.363676 70.99) (xy 166.36 70.952675) (xy 166.36 68.308072) (xy 166.365001 68.308072) (xy 166.365 77.996531) + (xy 166.360719 78.04) (xy 166.365 78.083469) (xy 166.365 78.083476) (xy 166.371068 78.145082) (xy 166.377805 78.21349) + (xy 166.392159 78.260808) (xy 166.428411 78.380312) (xy 166.44 78.401994) (xy 166.44 84.131928) (xy 164.956887 84.131928) + (xy 165.084609 83.940779) (xy 165.204089 83.652327) (xy 165.265 83.346109) (xy 165.265 83.033891) (xy 165.204089 82.727673) + (xy 165.084609 82.439221) (xy 165.041712 82.375021) (xy 165.08224 82.375021) (xy 165.24356 82.342932) (xy 165.395521 82.279988) + (xy 165.532281 82.188608) (xy 165.648587 82.072302) (xy 165.739967 81.935542) (xy 165.802911 81.783581) (xy 165.835 81.622261) + (xy 165.835 81.457781) (xy 165.802911 81.296461) (xy 165.76 81.192864) (xy 165.76 78.887157) (xy 165.802911 78.78356) + (xy 165.835 78.62224) (xy 165.835 78.45776) (xy 165.802911 78.29644) (xy 165.739967 78.144479) (xy 165.648587 78.007719) + (xy 165.532281 77.891413) (xy 165.395521 77.800033) (xy 165.24356 77.737089) (xy 165.08224 77.705) (xy 164.91776 77.705) + (xy 164.75644 77.737089) (xy 164.604479 77.800033) (xy 164.467719 77.891413) (xy 164.351413 78.007719) (xy 164.260033 78.144479) + (xy 164.197089 78.29644) (xy 164.165 78.45776) (xy 164.165 78.62224) (xy 164.197089 78.78356) (xy 164.24 78.887157) + (xy 164.240001 81.192862) (xy 164.197089 81.296461) (xy 164.165 81.457781) (xy 164.165 81.622261) (xy 164.176498 81.680065) + (xy 164.142327 81.665911) (xy 163.836109 81.605) (xy 163.523891 81.605) (xy 163.217673 81.665911) (xy 163.123303 81.705) + (xy 162.95374 81.705) (xy 162.666842 81.762068) (xy 162.396589 81.87401) (xy 162.153368 82.036525) (xy 161.946525 82.243368) + (xy 161.78401 82.486589) (xy 161.76 82.544555) (xy 161.76 79.703072) (xy 161.8 79.703072) (xy 161.924482 79.690812) + (xy 162.04418 79.654502) (xy 162.154494 79.595537) (xy 162.251185 79.516185) (xy 162.330537 79.419494) (xy 162.389502 79.30918) + (xy 162.425812 79.189482) (xy 162.438072 79.065) (xy 162.438072 78.52703) (xy 162.680497 78.284605) (xy 162.709494 78.260808) + (xy 162.804467 78.145083) (xy 162.875039 78.013054) (xy 162.918496 77.869793) (xy 162.922094 77.833265) (xy 162.972404 77.711805) + (xy 163.004493 77.550485) (xy 163.004493 77.386005) (xy 162.972404 77.224685) (xy 162.90946 77.072724) (xy 162.81808 76.935964) + (xy 162.701774 76.819658) (xy 162.565014 76.728278) (xy 162.413053 76.665334) (xy 162.317853 76.646397) (xy 162.435 76.52925) + (xy 162.438072 76.315) (xy 162.425812 76.190518) (xy 162.389502 76.07082) (xy 162.330537 75.960506) (xy 162.251185 75.863815) + (xy 162.154494 75.784463) (xy 162.04418 75.725498) (xy 161.924482 75.689188) (xy 161.8 75.676928) (xy 161.28575 75.68) + (xy 161.127002 75.838748) (xy 161.127002 75.68) (xy 161.06 75.68) (xy 161.06 75.491077) (xy 161.063435 75.4562) + (xy 161.049727 75.317016) (xy 161.009128 75.18318) (xy 160.9432 75.059837) (xy 160.854475 74.951725) (xy 160.746363 74.863) + (xy 160.62302 74.797072) (xy 160.489184 74.756473) (xy 160.384877 74.7462) (xy 160.35 74.742765) (xy 160.315123 74.7462) + (xy 156.884877 74.7462) (xy 156.85 74.742765) (xy 156.815123 74.7462) (xy 156.710816 74.756473) (xy 156.57698 74.797072) + (xy 156.453637 74.863) (xy 156.345525 74.951725) (xy 156.2568 75.059837) (xy 156.190872 75.18318) (xy 156.150273 75.317016) + (xy 156.136565 75.4562) (xy 156.140001 75.491087) (xy 156.140001 75.676928) (xy 155.4 75.676928) (xy 155.275518 75.689188) + (xy 155.15582 75.725498) (xy 155.045506 75.784463) (xy 154.948815 75.863815) (xy 154.869463 75.960506) (xy 154.818954 76.055) + (xy 154.449145 76.055) (xy 154.411812 76.051323) (xy 154.374479 76.055) (xy 154.262826 76.065997) (xy 154.119565 76.109454) + (xy 153.987536 76.180026) (xy 153.871811 76.274999) (xy 153.848013 76.303998) (xy 153.089002 77.063009) (xy 153.059999 77.086811) + (xy 153.015189 77.141413) (xy 152.965026 77.202536) (xy 152.912615 77.30059) (xy 152.894454 77.334566) (xy 152.850997 77.477827) + (xy 152.84 77.58948) (xy 152.84 77.58949) (xy 152.836324 77.626812) (xy 152.84 77.664134) (xy 152.84 77.692843) + (xy 152.797089 77.79644) (xy 152.765 77.95776) (xy 152.765 78.12224) (xy 152.797089 78.28356) (xy 152.860033 78.435521) + (xy 152.951413 78.572281) (xy 153.067719 78.688587) (xy 153.204479 78.779967) (xy 153.35644 78.842911) (xy 153.415003 78.85456) + (xy 153.415003 79.596523) (xy 153.410721 79.640002) (xy 153.427807 79.813492) (xy 153.478414 79.980315) (xy 153.560592 80.134061) + (xy 153.64347 80.235048) (xy 153.643473 80.235051) (xy 153.671186 80.268819) (xy 153.704953 80.296531) (xy 154.64347 81.235049) + (xy 154.671183 81.268817) (xy 154.704951 81.29653) (xy 154.704953 81.296532) (xy 154.784976 81.362205) (xy 154.805941 81.379411) + (xy 154.959687 81.461589) (xy 155.12651 81.512195) (xy 155.256523 81.525) (xy 155.256531 81.525) (xy 155.3 81.529281) + (xy 155.343469 81.525) (xy 156.483295 81.525) (xy 156.220583 81.918175) (xy 156.018183 82.406814) (xy 155.915 82.925551) + (xy 155.915 83.454449) (xy 156.018183 83.973186) (xy 156.023749 83.986623) (xy 155.801302 83.837989) (xy 155.492012 83.709877) + (xy 155.527932 83.623158) (xy 155.585 83.33626) (xy 155.585 83.04374) (xy 155.527932 82.756842) (xy 155.41599 82.486589) + (xy 155.253475 82.243368) (xy 155.046632 82.036525) (xy 154.803411 81.87401) (xy 154.533158 81.762068) (xy 154.24626 81.705) + (xy 154.076697 81.705) (xy 153.982327 81.665911) (xy 153.676109 81.605) (xy 153.363891 81.605) (xy 153.057673 81.665911) + (xy 152.769221 81.785391) (xy 152.509621 81.95885) (xy 152.28885 82.179621) (xy 152.115391 82.439221) (xy 151.995911 82.727673) + (xy 151.935 83.033891) (xy 151.935 83.346109) (xy 151.995911 83.652327) (xy 152.115391 83.940779) (xy 152.28885 84.200379) + (xy 152.509621 84.42115) (xy 152.769221 84.594609) (xy 152.935016 84.663283) (xy 152.897988 84.718699) (xy 152.737047 85.107245) + (xy 152.655 85.519722) (xy 152.655 85.94028) (xy 152.737047 86.352757) (xy 152.869252 86.671928) (xy 151.75 86.671928) + (xy 151.625518 86.684188) (xy 151.50582 86.720498) (xy 151.395506 86.779463) (xy 151.298815 86.858815) (xy 151.240386 86.930011) + (xy 151.195521 86.900033) (xy 151.091923 86.857122) (xy 150.51 86.275199) (xy 150.51 84.557683) (xy 150.579494 84.520537) + (xy 150.676185 84.441185) (xy 150.755537 84.344494) (xy 150.814502 84.23418) (xy 150.850812 84.114482) (xy 150.863072 83.99) + (xy 150.863072 82.69) (xy 150.850812 82.565518) (xy 150.814502 82.44582) (xy 150.755537 82.335506) (xy 150.676185 82.238815) + (xy 150.579494 82.159463) (xy 150.46918 82.100498) (xy 150.349482 82.064188) (xy 150.225 82.051928) (xy 149.275 82.051928) + (xy 149.150518 82.064188) (xy 149.03082 82.100498) (xy 148.920506 82.159463) (xy 148.823815 82.238815) (xy 148.744463 82.335506) + (xy 148.685498 82.44582) (xy 148.649188 82.565518) (xy 148.636928 82.69) (xy 148.636928 83.99) (xy 148.649188 84.114482) + (xy 148.685498 84.23418) (xy 148.744463 84.344494) (xy 148.823815 84.441185) (xy 148.920506 84.520537) (xy 148.99 84.557683) + (xy 148.990001 86.527333) (xy 148.991249 86.54) (xy 148.986324 86.59) (xy 149.000998 86.738985) (xy 149.044454 86.882246) + (xy 149.115026 87.014276) (xy 149.186201 87.101002) (xy 150.017122 87.931923) (xy 150.040001 87.987159) (xy 150.04 88.977177) + (xy 150.036324 89.0145) (xy 150.04 89.051822) (xy 150.04 89.051832) (xy 150.050997 89.163485) (xy 150.084578 89.274188) + (xy 150.094454 89.306746) (xy 150.165026 89.438776) (xy 150.193507 89.47348) (xy 150.259999 89.554501) (xy 150.289003 89.578304) + (xy 152.330498 91.6198) (xy 149.961123 91.6198) (xy 149.92379 91.616123) (xy 149.886457 91.6198) (xy 149.774804 91.630797) + (xy 149.631543 91.674254) (xy 149.499514 91.744826) (xy 149.383789 91.839799) (xy 149.359991 91.868797) (xy 148.388779 92.84001) + (xy 146.90329 92.84001) (xy 146.955546 92.742247) (xy 146.999003 92.598986) (xy 147.01 92.487333) (xy 147.01 92.487325) + (xy 147.013676 92.45) (xy 147.01 92.412675) (xy 147.01 89.818072) (xy 147.65 89.818072) (xy 147.774482 89.805812) + (xy 147.89418 89.769502) (xy 148.004494 89.710537) (xy 148.101185 89.631185) (xy 148.180537 89.534494) (xy 148.239502 89.42418) + (xy 148.275812 89.304482) (xy 148.288072 89.18) (xy 148.288072 87.18) (xy 148.275812 87.055518) (xy 148.239502 86.93582) + (xy 148.180537 86.825506) (xy 148.101185 86.728815) (xy 148.004494 86.649463) (xy 147.89418 86.590498) (xy 147.774482 86.554188) + (xy 147.65 86.541928) (xy 145.856887 86.541928) (xy 145.984609 86.350779) (xy 146.104089 86.062327) (xy 146.165 85.756109) + (xy 146.165 85.443891) (xy 146.104089 85.137673) (xy 145.984609 84.849221) (xy 145.81115 84.589621) (xy 145.590379 84.36885) + (xy 145.330779 84.195391) (xy 145.042327 84.075911) (xy 144.736109 84.015) (xy 144.423891 84.015) (xy 144.117673 84.075911) + (xy 144.023303 84.115) (xy 143.85374 84.115) (xy 143.566842 84.172068) (xy 143.296589 84.28401) (xy 143.053368 84.446525) + (xy 142.846525 84.653368) (xy 142.68401 84.896589) (xy 142.572068 85.166842) (xy 142.515 85.45374) (xy 142.515 85.74626) + (xy 142.572068 86.033158) (xy 142.607988 86.119876) (xy 142.298698 86.247988) (xy 142.076252 86.396622) (xy 142.081817 86.383186) + (xy 142.185 85.864449) (xy 142.185 85.335551) (xy 142.081817 84.816814) (xy 141.879417 84.328175) (xy 141.585576 83.888412) + (xy 141.257164 83.56) (xy 146.71269 83.56) (xy 146.750012 83.563676) (xy 146.787334 83.56) (xy 146.787345 83.56) + (xy 146.898998 83.549003) (xy 147.042259 83.505546) (xy 147.174288 83.434974) (xy 147.290013 83.340001) (xy 147.313815 83.310998) + (xy 147.791935 82.832878) (xy 147.895533 82.789967) (xy 148.032293 82.698587) (xy 148.148599 82.582281) (xy 148.239979 82.445521) + (xy 148.302923 82.29356) (xy 148.335012 82.13224) (xy 148.335012 81.96776) (xy 148.302923 81.80644) (xy 148.239979 81.654479) + (xy 148.148599 81.517719) (xy 148.032293 81.401413) (xy 147.895533 81.310033) (xy 147.743572 81.247089) (xy 147.582252 81.215) + (xy 147.417772 81.215) (xy 147.256452 81.247089) (xy 147.104491 81.310033) (xy 146.967731 81.401413) (xy 146.851425 81.517719) + (xy 146.760045 81.654479) (xy 146.717134 81.758077) (xy 146.435211 82.04) (xy 142.990019 82.04) (xy 143.054494 82.005537) + (xy 143.151185 81.926185) (xy 143.230537 81.829494) (xy 143.289502 81.71918) (xy 143.325812 81.599482) (xy 143.338072 81.475) + (xy 143.338072 81.286729) (xy 143.941923 80.682878) (xy 144.045521 80.639967) (xy 144.182281 80.548587) (xy 144.298587 80.432281) + (xy 144.389967 80.295521) (xy 144.452911 80.14356) (xy 144.485 79.98224) (xy 144.485 79.81776) (xy 144.452911 79.65644) + (xy 144.389967 79.504479) (xy 144.298587 79.367719) (xy 144.182281 79.251413) (xy 144.045521 79.160033) (xy 143.997157 79.14) + (xy 148.636928 79.14) (xy 148.636928 80.44) (xy 148.649188 80.564482) (xy 148.685498 80.68418) (xy 148.744463 80.794494) + (xy 148.823815 80.891185) (xy 148.915 80.966018) (xy 148.915 81.02224) (xy 148.947089 81.18356) (xy 149.010033 81.335521) + (xy 149.101413 81.472281) (xy 149.217719 81.588587) (xy 149.354479 81.679967) (xy 149.50644 81.742911) (xy 149.66776 81.775) + (xy 149.83224 81.775) (xy 149.99356 81.742911) (xy 150.145521 81.679967) (xy 150.282281 81.588587) (xy 150.398587 81.472281) + (xy 150.489967 81.335521) (xy 150.552911 81.18356) (xy 150.585 81.02224) (xy 150.585 80.966018) (xy 150.676185 80.891185) + (xy 150.755537 80.794494) (xy 150.814502 80.68418) (xy 150.850812 80.564482) (xy 150.863072 80.44) (xy 150.863072 79.14) + (xy 150.850812 79.015518) (xy 150.814502 78.89582) (xy 150.755537 78.785506) (xy 150.676185 78.688815) (xy 150.579494 78.609463) + (xy 150.46918 78.550498) (xy 150.349482 78.514188) (xy 150.225 78.501928) (xy 149.275 78.501928) (xy 149.150518 78.514188) + (xy 149.03082 78.550498) (xy 148.920506 78.609463) (xy 148.823815 78.688815) (xy 148.744463 78.785506) (xy 148.685498 78.89582) + (xy 148.649188 79.015518) (xy 148.636928 79.14) (xy 143.997157 79.14) (xy 143.89356 79.097089) (xy 143.73224 79.065) + (xy 143.56776 79.065) (xy 143.40644 79.097089) (xy 143.335 79.12668) (xy 143.335 79.097998) (xy 143.176252 79.097998) + (xy 143.335 78.93925) (xy 143.338072 78.725) (xy 143.325812 78.600518) (xy 143.289502 78.48082) (xy 143.230537 78.370506) + (xy 143.151185 78.273815) (xy 143.054494 78.194463) (xy 142.94418 78.135498) (xy 142.824482 78.099188) (xy 142.7 78.086928) + (xy 142.18575 78.09) (xy 142.027002 78.248748) (xy 142.027002 78.09) (xy 141.96 78.09) (xy 141.96 77.984877) + (xy 141.963435 77.95) (xy 141.949727 77.810816) (xy 141.909128 77.67698) (xy 141.8432 77.553637) (xy 141.754475 77.445525) + (xy 141.646363 77.3568) (xy 141.52302 77.290872) (xy 141.389184 77.250273) (xy 141.284877 77.24) (xy 141.25 77.236565) + (xy 141.215123 77.24) (xy 137.784877 77.24) (xy 137.75 77.236565) (xy 137.715123 77.24) (xy 137.610816 77.250273) + (xy 137.47698 77.290872) (xy 137.353637 77.3568) (xy 137.245525 77.445525) (xy 137.1568 77.553637) (xy 137.090872 77.67698) + (xy 137.050273 77.810816) (xy 137.036565 77.95) (xy 137.040001 77.984887) (xy 137.040001 78.086928) (xy 136.3 78.086928) + (xy 136.175518 78.099188) (xy 136.05582 78.135498) (xy 135.945506 78.194463) (xy 135.848815 78.273815) (xy 135.769463 78.370506) + (xy 135.710498 78.48082) (xy 135.674188 78.600518) (xy 135.663209 78.711989) (xy 135.26 79.115199) (xy 135.26 79.081523) + (xy 135.247195 78.95151) (xy 135.196589 78.784687) (xy 135.114411 78.630941) (xy 135.003817 78.496183) (xy 134.869059 78.385589) + (xy 134.715313 78.303411) (xy 134.54849 78.252805) (xy 134.375 78.235718) (xy 134.201511 78.252805) (xy 134.034688 78.303411) + (xy 133.880942 78.385589) (xy 133.746184 78.496183) (xy 133.63559 78.630941) (xy 133.553412 78.784687) (xy 133.502806 78.95151) + (xy 133.490001 79.081523) (xy 133.49 80.28153) (xy 133.485719 80.325) (xy 133.49 80.368469) (xy 133.49 80.368476) + (xy 133.49737 80.443303) (xy 133.502805 80.49849) (xy 133.511305 80.52651) (xy 133.553411 80.665312) (xy 133.635589 80.819058) + (xy 133.746183 80.953817) (xy 133.779956 80.981534) (xy 134.268466 81.470044) (xy 134.296183 81.503817) (xy 134.430941 81.614411) + (xy 134.584687 81.696589) (xy 134.75151 81.747195) (xy 134.881523 81.76) (xy 134.881533 81.76) (xy 134.924999 81.764281) + (xy 134.968465 81.76) (xy 135.732317 81.76) (xy 135.769463 81.829494) (xy 135.848815 81.926185) (xy 135.945506 82.005537) + (xy 136.009981 82.04) (xy 132.464802 82.04) (xy 132.363072 81.93827) (xy 132.363072 81.25) (xy 132.350812 81.125518) + (xy 132.314502 81.00582) (xy 132.255537 80.895506) (xy 132.176185 80.798815) (xy 132.079494 80.719463) (xy 131.96918 80.660498) + (xy 131.849482 80.624188) (xy 131.725 80.611928) (xy 130.775 80.611928) (xy 130.650518 80.624188) (xy 130.53082 80.660498) + (xy 130.420506 80.719463) (xy 130.323815 80.798815) (xy 130.244463 80.895506) (xy 130.185498 81.00582) (xy 130.162691 81.081003) + (xy 130.08224 81.065) (xy 129.91776 81.065) (xy 129.75644 81.097089) (xy 129.652843 81.14) (xy 129.57487 81.14) + (xy 129.564502 81.10582) (xy 129.505537 80.995506) (xy 129.426185 80.898815) (xy 129.329494 80.819463) (xy 129.21918 80.760498) + (xy 129.099482 80.724188) (xy 128.975 80.711928) (xy 128.025 80.711928) (xy 127.900518 80.724188) (xy 127.78082 80.760498) + (xy 127.670506 80.819463) (xy 127.601169 80.876367) (xy 124.609802 77.885001) (xy 125.787677 77.885001) (xy 125.824999 77.888677) + (xy 125.862321 77.885001) (xy 125.862332 77.885001) (xy 125.973985 77.874004) (xy 126.117246 77.830547) (xy 126.249275 77.759975) + (xy 126.365 77.665002) (xy 126.388803 77.635998) (xy 128.011003 76.013799) (xy 128.040001 75.990001) (xy 128.071669 75.951413) + (xy 128.134974 75.874277) (xy 128.205546 75.742247) (xy 128.208437 75.732715) (xy 128.249003 75.598986) (xy 128.26 75.487333) + (xy 128.26 75.487324) (xy 128.263676 75.450001) (xy 128.26 75.412678) (xy 128.26 73.318072) (xy 128.65 73.318072) + (xy 128.774482 73.305812) (xy 128.89418 73.269502) (xy 129.004494 73.210537) (xy 129.101185 73.131185) (xy 129.180537 73.034494) + (xy 129.239502 72.92418) (xy 129.275812 72.804482) (xy 129.288072 72.68) (xy 129.288072 70.68) (xy 129.275812 70.555518) + (xy 129.239502 70.43582) (xy 129.180537 70.325506) (xy 129.101185 70.228815) (xy 129.004494 70.149463) (xy 128.89418 70.090498) + (xy 128.774482 70.054188) (xy 128.65 70.041928) (xy 128.26 70.041928) (xy 128.26 67.337322) (xy 128.263676 67.299999) + (xy 128.26 67.262676) (xy 128.26 67.262667) (xy 128.249003 67.151014) (xy 128.205546 67.007753) (xy 128.134974 66.875724) + (xy 128.121811 66.859685) (xy 128.063799 66.788996) (xy 128.063795 66.788992) (xy 128.040001 66.759999) (xy 128.011009 66.736206) + (xy 127.813813 66.539011) (xy 127.864502 66.44418) (xy 127.900812 66.324482) (xy 127.913072 66.2) (xy 127.913072 64.925) + (xy 128.686928 64.925) (xy 128.686928 66.225) (xy 128.699188 66.349482) (xy 128.735498 66.46918) (xy 128.794463 66.579494) + (xy 128.873815 66.676185) (xy 128.970506 66.755537) (xy 129.08082 66.814502) (xy 129.200518 66.850812) (xy 129.325 66.863072) + (xy 130.275 66.863072) (xy 130.399482 66.850812) (xy 130.51918 66.814502) (xy 130.629494 66.755537) (xy 130.726185 66.676185) + (xy 130.805537 66.579494) (xy 130.864502 66.46918) (xy 130.877311 66.426954) (xy 130.91776 66.435) (xy 131.08224 66.435) + (xy 131.24356 66.402911) (xy 131.395521 66.339967) (xy 131.532281 66.248587) (xy 131.648587 66.132281) (xy 131.739967 65.995521) + (xy 131.802911 65.84356) (xy 131.835 65.68224) (xy 131.835 65.51776) (xy 131.802911 65.35644) (xy 131.739967 65.204479) + (xy 131.648587 65.067719) (xy 131.532281 64.951413) (xy 131.395521 64.860033) (xy 131.24356 64.797089) (xy 131.08224 64.765) + (xy 130.91776 64.765) (xy 130.891615 64.770201) (xy 130.864502 64.68082) (xy 130.805537 64.570506) (xy 130.726185 64.473815) + (xy 130.629494 64.394463) (xy 130.51918 64.335498) (xy 130.399482 64.299188) (xy 130.275 64.286928) (xy 129.325 64.286928) + (xy 129.200518 64.299188) (xy 129.08082 64.335498) (xy 128.970506 64.394463) (xy 128.873815 64.473815) (xy 128.794463 64.570506) + (xy 128.735498 64.68082) (xy 128.699188 64.800518) (xy 128.686928 64.925) (xy 127.913072 64.925) (xy 127.913072 64.9) + (xy 127.900812 64.775518) (xy 127.864502 64.65582) (xy 127.805537 64.545506) (xy 127.726185 64.448815) (xy 127.629494 64.369463) + (xy 127.51918 64.310498) (xy 127.43104 64.283761) (xy 128.531923 63.182878) (xy 128.587155 63.16) (xy 128.915019 63.16) + (xy 128.970506 63.205537) (xy 129.08082 63.264502) (xy 129.200518 63.300812) (xy 129.325 63.313072) (xy 130.275 63.313072) + (xy 130.399482 63.300812) (xy 130.51918 63.264502) (xy 130.629494 63.205537) (xy 130.726185 63.126185) (xy 130.782619 63.05742) + (xy 131.986205 64.261008) (xy 132.009999 64.290001) (xy 132.038992 64.313795) (xy 132.038996 64.313799) (xy 132.101417 64.365026) + (xy 132.125724 64.384974) (xy 132.257753 64.455546) (xy 132.401014 64.499003) (xy 132.512667 64.51) (xy 132.512676 64.51) + (xy 132.549999 64.513676) (xy 132.587322 64.51) (xy 133.107199 64.51) (xy 133.158196 64.560997) (xy 133.181999 64.590001) + (xy 133.297724 64.684974) (xy 133.429753 64.755546) (xy 133.573014 64.799003) (xy 133.684667 64.81) (xy 133.684676 64.81) + (xy 133.721999 64.813676) (xy 133.759322 64.81) (xy 137.492836 64.81) (xy 137.414424 64.888412) (xy 137.120583 65.328175) + (xy 136.918183 65.816814) (xy 136.815 66.335551) (xy 136.815 66.864449) (xy 136.918183 67.383186) (xy 136.923749 67.396623) + (xy 136.701302 67.247989) (xy 136.392012 67.119877) (xy 136.427932 67.033158) (xy 136.485 66.74626) (xy 136.485 66.45374) + (xy 136.427932 66.166842) (xy 136.31599 65.896589) (xy 136.153475 65.653368) (xy 135.946632 65.446525) (xy 135.703411 65.28401) + (xy 135.433158 65.172068) (xy 135.14626 65.115) (xy 134.976697 65.115) (xy 134.882327 65.075911) (xy 134.576109 65.015) + (xy 134.263891 65.015) (xy 133.957673 65.075911) (xy 133.669221 65.195391) (xy 133.409621 65.36885) (xy 133.18885 65.589621) + (xy 133.015391 65.849221) (xy 132.895911 66.137673) (xy 132.835 66.443891) (xy 132.835 66.756109) (xy 132.895911 67.062327) + (xy 133.015391 67.350779) (xy 133.18885 67.610379) (xy 133.409621 67.83115) (xy 133.669221 68.004609) (xy 133.835016 68.073283) + (xy 133.797988 68.128699) (xy 133.637047 68.517245) (xy 133.555 68.929722) (xy 133.555 69.35028) (xy 133.637047 69.762757) + (xy 133.769252 70.081928) (xy 132.65 70.081928) (xy 132.525518 70.094188) (xy 132.40582 70.130498) (xy 132.295506 70.189463) + (xy 132.270401 70.210066) (xy 132.195521 70.160033) (xy 132.04356 70.097089) (xy 131.88224 70.065) (xy 131.71776 70.065) + (xy 131.55644 70.097089) (xy 131.404479 70.160033) (xy 131.267719 70.251413) (xy 131.151413 70.367719) (xy 131.060033 70.504479) + (xy 130.997089 70.65644) (xy 130.965 70.81776) (xy 130.965 70.98224) (xy 130.997089 71.14356) (xy 131.040001 71.247159) + (xy 131.04 73.662679) (xy 131.036324 73.700002) (xy 131.04 73.737324) (xy 131.04 73.737334) (xy 131.050997 73.848987) + (xy 131.084591 73.959733) (xy 131.094454 73.992248) (xy 131.165026 74.124278) (xy 131.195167 74.161004) (xy 131.259999 74.240003) + (xy 131.289002 74.263805) (xy 131.961204 74.936009) (xy 131.984998 74.965002) (xy 132.013991 74.988796) (xy 132.013995 74.9888) + (xy 132.058989 75.025725) (xy 132.100723 75.059975) (xy 132.232752 75.130547) (xy 132.376013 75.174004) (xy 132.487666 75.185001) + (xy 132.487675 75.185001) (xy 132.524998 75.188677) (xy 132.562321 75.185001) (xy 145.487677 75.185001) (xy 145.524999 75.188677) + (xy 145.562321 75.185001) (xy 145.562332 75.185001) (xy 145.673985 75.174004) (xy 145.817246 75.130547) (xy 145.949275 75.059975) + (xy 146.065 74.965002) (xy 146.088803 74.935999) (xy 147.011003 74.013799) (xy 147.040001 73.990001) (xy 147.134974 73.874276) + (xy 147.205546 73.742247) (xy 147.249003 73.598986) (xy 147.26 73.487333) (xy 147.26 73.487325) (xy 147.263676 73.45) + (xy 147.26 73.412675) (xy 147.26 70.818072) (xy 147.65 70.818072) (xy 147.774482 70.805812) (xy 147.89418 70.769502) + (xy 148.004494 70.710537) (xy 148.101185 70.631185) (xy 148.180537 70.534494) (xy 148.239502 70.42418) (xy 148.275812 70.304482) + (xy 148.288072 70.18) (xy 148.288072 68.18) (xy 148.275812 68.055518) (xy 148.239502 67.93582) (xy 148.180537 67.825506) + (xy 148.101185 67.728815) (xy 148.004494 67.649463) (xy 147.89418 67.590498) (xy 147.774482 67.554188) (xy 147.65 67.541928) + (xy 145.856887 67.541928) (xy 145.984609 67.350779) (xy 146.104089 67.062327) (xy 146.165 66.756109) (xy 146.165 66.443891) + (xy 146.104089 66.137673) (xy 145.984609 65.849221) (xy 145.81115 65.589621) (xy 145.590379 65.36885) (xy 145.330779 65.195391) + (xy 145.042327 65.075911) (xy 144.736109 65.015) (xy 144.423891 65.015) (xy 144.117673 65.075911) (xy 144.023303 65.115) + (xy 143.85374 65.115) (xy 143.566842 65.172068) (xy 143.296589 65.28401) (xy 143.053368 65.446525) (xy 142.846525 65.653368) + (xy 142.68401 65.896589) (xy 142.572068 66.166842) (xy 142.515 66.45374) (xy 142.515 66.74626) (xy 142.572068 67.033158) + (xy 142.607988 67.119876) (xy 142.298698 67.247988) (xy 142.076252 67.396622) (xy 142.081817 67.383186) (xy 142.185 66.864449) + (xy 142.185 66.335551) (xy 142.081817 65.816814) (xy 141.879417 65.328175) (xy 141.585576 64.888412) (xy 141.507164 64.81) + (xy 143.212678 64.81) (xy 143.25 64.813676) (xy 143.287322 64.81) (xy 143.287333 64.81) (xy 143.398986 64.799003) + (xy 143.542247 64.755546) (xy 143.674276 64.684974) (xy 143.790001 64.590001) (xy 143.813804 64.560997) (xy 146.478202 61.8966) + (xy 146.61484 61.8966) (xy 146.77616 61.864511) (xy 146.928121 61.801567) (xy 147.064881 61.710187) (xy 147.181187 61.593881) + (xy 147.272567 61.457121) (xy 147.335511 61.30516) (xy 147.3676 61.14384) (xy 147.3676 60.97936) (xy 147.335511 60.81804) + (xy 147.272567 60.666079) (xy 147.181187 60.529319) (xy 147.064881 60.413013) (xy 146.928121 60.321633) (xy 146.77616 60.258689) + (xy 146.61484 60.2266) (xy 146.45036 60.2266) (xy 146.28904 60.258689) (xy 146.180569 60.303619) (xy 146.089414 60.312597) + (xy 145.946153 60.356054) (xy 145.814124 60.426626) (xy 145.698399 60.521599) (xy 145.674601 60.550597) (xy 142.935199 63.29) + (xy 141.96 63.29) (xy 141.96 63.113072) (xy 142.7 63.113072) (xy 142.824482 63.100812) (xy 142.94418 63.064502) + (xy 143.054494 63.005537) (xy 143.151185 62.926185) (xy 143.230537 62.829494) (xy 143.289502 62.71918) (xy 143.325812 62.599482) + (xy 143.338072 62.475) (xy 143.338072 62.036723) (xy 143.641923 61.732872) (xy 143.745521 61.689961) (xy 143.882281 61.598581) + (xy 143.998587 61.482275) (xy 144.089967 61.345515) (xy 144.152911 61.193554) (xy 144.185 61.032234) (xy 144.185 60.867754) + (xy 144.152911 60.706434) (xy 144.089967 60.554473) (xy 143.998587 60.417713) (xy 143.882281 60.301407) (xy 143.745521 60.210027) + (xy 143.59356 60.147083) (xy 143.43224 60.114994) (xy 143.335 60.114994) (xy 143.335 60.097998) (xy 143.176252 60.097998) + (xy 143.335 59.93925) (xy 143.338072 59.725) (xy 143.325812 59.600518) (xy 143.289502 59.48082) (xy 143.230537 59.370506) + (xy 143.151185 59.273815) (xy 143.054494 59.194463) (xy 142.94418 59.135498) (xy 142.824482 59.099188) (xy 142.7 59.086928) + (xy 142.18575 59.09) (xy 142.027002 59.248748) (xy 142.027002 59.09) (xy 141.96 59.09) (xy 141.96 58.984877) + (xy 141.963435 58.95) (xy 141.949727 58.810816) (xy 141.909128 58.67698) (xy 141.8432 58.553637) (xy 141.754475 58.445525) + (xy 141.646363 58.3568) (xy 141.52302 58.290872) (xy 141.389184 58.250273) (xy 141.284877 58.24) (xy 141.25 58.236565) + (xy 141.215123 58.24) (xy 137.784877 58.24) (xy 137.75 58.236565) (xy 137.715123 58.24) (xy 137.610816 58.250273) + (xy 137.47698 58.290872) (xy 137.353637 58.3568) (xy 137.245525 58.445525) (xy 137.1568 58.553637) (xy 137.090872 58.67698) + (xy 137.050273 58.810816) (xy 137.036565 58.95) (xy 137.040001 58.984887) (xy 137.040001 59.086928) (xy 136.3 59.086928) + (xy 136.175518 59.099188) (xy 136.05582 59.135498) (xy 135.945506 59.194463) (xy 135.848815 59.273815) (xy 135.77598 59.362565) + (xy 135.665313 59.303412) (xy 135.498489 59.252806) (xy 135.324999 59.235719) (xy 135.151509 59.252806) (xy 134.984687 59.303412) + (xy 134.830941 59.38559) (xy 134.729954 59.468468) (xy 134.40495 59.793472) (xy 134.371182 59.821185) (xy 134.343469 59.854953) + (xy 134.343466 59.854956) (xy 134.260588 59.955943) (xy 134.17841 60.109689) (xy 134.127803 60.276512) (xy 134.122311 60.332281) + (xy 134.114998 60.406525) (xy 134.114998 60.406533) (xy 134.110717 60.450002) (xy 134.114998 60.493471) (xy 134.114998 61.218533) + (xy 134.110717 61.262002) (xy 134.114998 61.305471) (xy 134.114998 61.305478) (xy 134.12553 61.412408) (xy 134.127803 61.435492) + (xy 134.136762 61.465025) (xy 134.178409 61.602314) (xy 134.260587 61.75606) (xy 134.371181 61.890819) (xy 134.404954 61.918536) + (xy 134.956466 62.470049) (xy 134.984179 62.503817) (xy 135.017947 62.53153) (xy 135.017949 62.531532) (xy 135.077673 62.580546) + (xy 135.118937 62.614411) (xy 135.272683 62.696589) (xy 135.439506 62.747195) (xy 135.569519 62.76) (xy 135.569529 62.76) + (xy 135.612995 62.764281) (xy 135.656462 62.76) (xy 135.732317 62.76) (xy 135.769463 62.829494) (xy 135.848815 62.926185) + (xy 135.945506 63.005537) (xy 136.05582 63.064502) (xy 136.175518 63.100812) (xy 136.3 63.113072) (xy 137.04 63.113072) + (xy 137.04 63.29) (xy 134.036801 63.29) (xy 133.985804 63.239003) (xy 133.962001 63.209999) (xy 133.846276 63.115026) + (xy 133.714247 63.044454) (xy 133.570986 63.000997) (xy 133.459333 62.99) (xy 133.459322 62.99) (xy 133.422 62.986324) + (xy 133.384678 62.99) (xy 132.864803 62.99) (xy 131.388803 61.514002) (xy 131.365001 61.484999) (xy 131.249276 61.390026) + (xy 131.117247 61.319454) (xy 130.973986 61.275997) (xy 130.902629 61.268969) (xy 130.900812 61.250518) (xy 130.864502 61.13082) + (xy 130.805537 61.020506) (xy 130.726185 60.923815) (xy 130.629494 60.844463) (xy 130.51918 60.785498) (xy 130.399482 60.749188) + (xy 130.275 60.736928) (xy 129.325 60.736928) (xy 129.200518 60.749188) (xy 129.08082 60.785498) (xy 128.970506 60.844463) + (xy 128.873815 60.923815) (xy 128.794463 61.020506) (xy 128.735498 61.13082) (xy 128.699188 61.250518) (xy 128.686928 61.375) + (xy 128.686928 61.64) (xy 128.587155 61.64) (xy 128.531921 61.617121) (xy 128.403801 61.489002) (xy 128.379999 61.459999) + (xy 128.264274 61.365026) (xy 128.132245 61.294454) (xy 127.988984 61.250997) (xy 127.902482 61.242477) (xy 127.900812 61.225518) + (xy 127.864502 61.10582) (xy 127.805537 60.995506) (xy 127.726185 60.898815) (xy 127.629494 60.819463) (xy 127.51918 60.760498) + (xy 127.399482 60.724188) (xy 127.275 60.711928) (xy 126.66 60.711928) (xy 126.66 60.274145) (xy 126.663677 60.236812) + (xy 126.649003 60.087826) (xy 126.605546 59.944565) (xy 126.534974 59.812536) (xy 126.49098 59.758929) (xy 126.440001 59.696811) + (xy 126.411002 59.673013) (xy 125.726991 58.989002) (xy 125.703189 58.959999) (xy 125.587464 58.865026) (xy 125.455435 58.794454) + (xy 125.312174 58.750997) (xy 125.200521 58.74) (xy 125.20051 58.74) (xy 125.163188 58.736324) (xy 125.125866 58.74) + (xy 124.947157 58.74) (xy 124.891922 58.717121) (xy 124.713804 58.539003) (xy 124.690001 58.509999) (xy 124.574276 58.415026) + (xy 124.471331 58.36) (xy 125.362678 58.36) (xy 125.4 58.363676) (xy 125.437322 58.36) (xy 125.437333 58.36) + (xy 125.548986 58.349003) (xy 125.692247 58.305546) (xy 125.824276 58.234974) (xy 125.940001 58.140001) (xy 125.963803 58.110998) + (xy 126.511002 57.5638) (xy 126.540001 57.540001) (xy 126.583557 57.486928) (xy 126.634974 57.424277) (xy 126.705546 57.292247) + (xy 126.718361 57.25) (xy 126.749003 57.148986) (xy 126.76 57.037333) (xy 126.76 57.037324) (xy 126.763676 57.000001) + (xy 126.76 56.962678) (xy 126.76 56.314801) (xy 127.259974 55.814828) (xy 127.129712 56.129308) (xy 127.015 56.706003) + (xy 127.015 57.293997) (xy 127.129712 57.870692) (xy 127.354727 58.413928) (xy 127.681399 58.902826) (xy 128.097174 59.318601) + (xy 128.586072 59.645273) (xy 129.129308 59.870288) (xy 129.706003 59.985) (xy 130.293997 59.985) (xy 130.870692 59.870288) + (xy 131.413928 59.645273) (xy 131.902826 59.318601) (xy 132.318601 58.902826) (xy 132.645273 58.413928) (xy 132.870288 57.870692) + (xy 132.985 57.293997) (xy 132.985 56.706003) (xy 132.948698 56.523499) (xy 134.236201 57.811003) (xy 134.259999 57.840001) + (xy 134.375724 57.934974) (xy 134.507753 58.005546) (xy 134.651014 58.049003) (xy 134.762667 58.06) (xy 134.762675 58.06) + (xy 134.8 58.063676) (xy 134.837325 58.06) (xy 146.152843 58.06) (xy 146.25644 58.102911) (xy 146.41776 58.135) + (xy 146.58224 58.135) (xy 146.74356 58.102911) (xy 146.895521 58.039967) (xy 147.032281 57.948587) (xy 147.148587 57.832281) + (xy 147.239967 57.695521) (xy 147.302911 57.54356) (xy 147.335 57.38224) (xy 147.335 57.21776) (xy 147.302911 57.05644) + (xy 147.239967 56.904479) (xy 147.148587 56.767719) (xy 147.032281 56.651413) (xy 146.895521 56.560033) (xy 146.74356 56.497089) + (xy 146.58224 56.465) (xy 146.41776 56.465) (xy 146.25644 56.497089) (xy 146.152843 56.54) (xy 135.114802 56.54) + (xy 132.832873 54.258072) (xy 134.313271 54.258072) (xy 135.493701 55.438503) (xy 135.517499 55.467501) (xy 135.546497 55.491299) + (xy 135.633223 55.562474) (xy 135.729015 55.613676) (xy 135.765253 55.633046) (xy 135.773549 55.635563) (xy 135.785585 55.69607) + (xy 135.848529 55.848031) (xy 135.939909 55.984791) (xy 136.056215 56.101097) (xy 136.192975 56.192477) (xy 136.344936 56.255421) + (xy 136.506256 56.28751) (xy 136.670736 56.28751) (xy 136.832056 56.255421) (xy 136.935653 56.21251) (xy 144.460168 56.21251) + (xy 144.49749 56.216186) (xy 144.534812 56.21251) (xy 144.534823 56.21251) (xy 144.646476 56.201513) (xy 144.789737 56.158056) + (xy 144.921766 56.087484) (xy 145.037491 55.992511) (xy 145.061294 55.963507) (xy 147.011003 54.013799) (xy 147.040001 53.990001) + (xy 147.134974 53.874276) (xy 147.205546 53.742247) (xy 147.249003 53.598986) (xy 147.26 53.487333) (xy 147.26 53.487323) + (xy 147.263676 53.45) (xy 147.26 53.412677) (xy 147.26 51.718072) (xy 147.65 51.718072) (xy 147.774482 51.705812) + (xy 147.89418 51.669502) (xy 148.004494 51.610537) (xy 148.101185 51.531185) (xy 148.180537 51.434494) (xy 148.239502 51.32418) + (xy 148.275812 51.204482) (xy 148.288072 51.08) (xy 148.288072 49.08) (xy 148.275812 48.955518) (xy 148.239502 48.83582) + (xy 148.180537 48.725506) (xy 148.101185 48.628815) (xy 148.004494 48.549463) (xy 147.89418 48.490498) (xy 147.774482 48.454188) + (xy 147.65 48.441928) (xy 145.856887 48.441928) (xy 145.984609 48.250779) (xy 146.104089 47.962327) (xy 146.165 47.656109) + (xy 146.165 47.343891) (xy 146.104089 47.037673) (xy 145.984609 46.749221) (xy 145.81115 46.489621) (xy 145.590379 46.26885) + (xy 145.330779 46.095391) (xy 145.042327 45.975911) (xy 144.736109 45.915) (xy 144.423891 45.915) (xy 144.117673 45.975911) + (xy 144.023303 46.015) (xy 143.85374 46.015) (xy 143.566842 46.072068) (xy 143.296589 46.18401) (xy 143.053368 46.346525) + (xy 142.846525 46.553368) (xy 142.68401 46.796589) (xy 142.572068 47.066842) (xy 142.515 47.35374) (xy 142.515 47.64626) + (xy 142.572068 47.933158) (xy 142.607988 48.019876) (xy 142.298698 48.147988) (xy 142.076252 48.296622) (xy 142.081817 48.283186) + (xy 142.185 47.764449) (xy 142.185 47.235551) (xy 142.081817 46.716814) (xy 141.879417 46.228175) (xy 141.585576 45.788412) + (xy 141.550903 45.753739) (xy 141.598986 45.749003) (xy 141.742247 45.705546) (xy 141.874276 45.634974) (xy 141.990001 45.540001) + (xy 142.013804 45.510997) (xy 142.410998 45.113803) (xy 142.440001 45.090001) (xy 142.506372 45.009128) (xy 142.534974 44.974277) + (xy 142.605546 44.842247) (xy 142.612373 44.81974) (xy 142.649003 44.698986) (xy 142.66 44.587333) (xy 142.66 44.587324) + (xy 142.663676 44.550001) (xy 142.66 44.512678) (xy 142.66 44.013072) (xy 142.7 44.013072) (xy 142.824482 44.000812) + (xy 142.94418 43.964502) (xy 143.054494 43.905537) (xy 143.151185 43.826185) (xy 143.230537 43.729494) (xy 143.289502 43.61918) + (xy 143.325812 43.499482) (xy 143.338072 43.375) (xy 143.338072 42.767476) (xy 143.532296 42.573251) (xy 143.635894 42.53034) + (xy 143.772654 42.43896) (xy 143.88896 42.322654) (xy 143.98034 42.185894) (xy 144.043284 42.033933) (xy 144.075373 41.872613) + (xy 144.075373 41.708133) (xy 144.043284 41.546813) (xy 143.98034 41.394852) (xy 143.88896 41.258092) (xy 143.772654 41.141786) + (xy 143.635894 41.050406) (xy 143.483933 40.987462) (xy 143.322613 40.955373) (xy 143.218877 40.955373) (xy 143.335 40.83925) + (xy 143.338072 40.625) (xy 143.325812 40.500518) (xy 143.298357 40.410011) (xy 148.999481 40.410011) (xy 149.036803 40.413687) + (xy 149.074125 40.410011) (xy 149.074136 40.410011) (xy 149.185789 40.399014) (xy 149.32905 40.355557) (xy 149.391828 40.322001) + (xy 149.461593 40.322001) + ) + ) + (filled_polygon + (pts + (xy 127.872028 84.28283) (xy 127.78082 84.310498) (xy 127.670506 84.369463) (xy 127.573815 84.448815) (xy 127.494463 84.545506) + (xy 127.435498 84.65582) (xy 127.399188 84.775518) (xy 127.386928 84.9) (xy 127.386928 86.2) (xy 127.399188 86.324482) + (xy 127.435498 86.44418) (xy 127.494463 86.554494) (xy 127.573815 86.651185) (xy 127.670506 86.730537) (xy 127.681212 86.736259) + (xy 127.665 86.81776) (xy 127.665 86.98224) (xy 127.697089 87.14356) (xy 127.74 87.247157) (xy 127.740001 89.041928) + (xy 126.856887 89.041928) (xy 126.984609 88.850779) (xy 127.104089 88.562327) (xy 127.165 88.256109) (xy 127.165 87.943891) + (xy 127.104089 87.637673) (xy 126.984609 87.349221) (xy 126.81115 87.089621) (xy 126.590379 86.86885) (xy 126.330779 86.695391) + (xy 126.042327 86.575911) (xy 125.736109 86.515) (xy 125.423891 86.515) (xy 125.117673 86.575911) (xy 125.023303 86.615) + (xy 124.85374 86.615) (xy 124.566842 86.672068) (xy 124.296589 86.78401) (xy 124.053368 86.946525) (xy 123.846525 87.153368) + (xy 123.68401 87.396589) (xy 123.572068 87.666842) (xy 123.515 87.95374) (xy 123.515 88.24626) (xy 123.572068 88.533158) + (xy 123.607988 88.619876) (xy 123.298698 88.747988) (xy 123.076252 88.896622) (xy 123.081817 88.883186) (xy 123.185 88.364449) + (xy 123.185 87.835551) (xy 123.081817 87.316814) (xy 122.879417 86.828175) (xy 122.585576 86.388412) (xy 122.211588 86.014424) + (xy 121.771825 85.720583) (xy 121.384142 85.56) (xy 122.215123 85.56) (xy 122.25 85.563435) (xy 122.284877 85.56) + (xy 122.369771 85.551639) (xy 122.389184 85.549727) (xy 122.52302 85.509128) (xy 122.646363 85.4432) (xy 122.754475 85.354475) + (xy 122.8432 85.246363) (xy 122.909128 85.12302) (xy 122.949727 84.989184) (xy 122.959145 84.89356) (xy 122.963435 84.85) + (xy 122.96 84.815123) (xy 122.96 84.613072) (xy 123.7 84.613072) (xy 123.824482 84.600812) (xy 123.94418 84.564502) + (xy 124.054494 84.505537) (xy 124.151185 84.426185) (xy 124.230537 84.329494) (xy 124.281046 84.235) (xy 125.047045 84.235) + (xy 125.054479 84.239967) (xy 125.20644 84.302911) (xy 125.36776 84.335) (xy 125.53224 84.335) (xy 125.69356 84.302911) + (xy 125.845521 84.239967) (xy 125.982281 84.148587) (xy 126.098587 84.032281) (xy 126.189967 83.895521) (xy 126.252911 83.74356) + (xy 126.285 83.58224) (xy 126.285 83.41776) (xy 126.252911 83.25644) (xy 126.189967 83.104479) (xy 126.098587 82.967719) + (xy 125.982281 82.851413) (xy 125.845521 82.760033) (xy 125.69356 82.697089) (xy 125.53224 82.665) (xy 125.36776 82.665) + (xy 125.20644 82.697089) (xy 125.163199 82.715) (xy 124.281046 82.715) (xy 124.230537 82.620506) (xy 124.213708 82.6) + (xy 124.230537 82.579494) (xy 124.289502 82.46918) (xy 124.325812 82.349482) (xy 124.338072 82.225) (xy 124.335 82.01075) + (xy 124.17625 81.852) (xy 123.027 81.852) (xy 123.027 81.872) (xy 122.96 81.872) (xy 122.96 81.578) + (xy 123.027 81.578) (xy 123.027 81.598) (xy 124.17625 81.598) (xy 124.335 81.43925) (xy 124.338072 81.225) + (xy 124.325812 81.100518) (xy 124.289502 80.98082) (xy 124.230537 80.870506) (xy 124.151185 80.773815) (xy 124.054494 80.694463) + (xy 123.94418 80.635498) (xy 123.824482 80.599188) (xy 123.7 80.586928) (xy 123.18575 80.59) (xy 123.027002 80.748748) + (xy 123.027002 80.59) (xy 122.96 80.59) (xy 122.96 80.384877) (xy 122.963435 80.35) (xy 122.949727 80.210816) + (xy 122.909128 80.07698) (xy 122.8432 79.953637) (xy 122.754475 79.845525) (xy 122.650262 79.76) (xy 123.349199 79.76) + ) + ) + (filled_polygon + (pts + (xy 115.796183 84.103817) (xy 115.930941 84.214411) (xy 116.084687 84.296589) (xy 116.25151 84.347195) (xy 116.381523 84.36) + (xy 116.381533 84.36) (xy 116.424999 84.364281) (xy 116.468466 84.36) (xy 116.794499 84.36) (xy 116.848815 84.426185) + (xy 116.945506 84.505537) (xy 117.05582 84.564502) (xy 117.175518 84.600812) (xy 117.3 84.613072) (xy 118.04 84.613072) + (xy 118.04 84.815123) (xy 118.036565 84.85) (xy 118.050273 84.989184) (xy 118.090872 85.12302) (xy 118.1568 85.246363) + (xy 118.245525 85.354475) (xy 118.330571 85.42427) (xy 118.353637 85.4432) (xy 118.47698 85.509128) (xy 118.610816 85.549727) + (xy 118.75 85.563435) (xy 118.784877 85.56) (xy 119.615858 85.56) (xy 119.228175 85.720583) (xy 118.788412 86.014424) + (xy 118.414424 86.388412) (xy 118.120583 86.828175) (xy 118.087914 86.907046) (xy 118.032281 86.851413) (xy 117.895521 86.760033) + (xy 117.791925 86.717122) (xy 115.759994 84.685193) (xy 115.759994 84.147157) (xy 115.784063 84.089049) + ) + ) + (filled_polygon + (pts + (xy 103.688351 75.781732) (xy 103.931032 75.882254) (xy 104.06499 75.9089) (xy 104.064991 84.489014) (xy 103.83575 84.49) + (xy 103.677 84.64875) (xy 103.677 85.498) (xy 103.697 85.498) (xy 103.697 85.743928) (xy 103.670049 85.741274) + (xy 103.632727 85.74495) (xy 103.632717 85.74495) (xy 103.521064 85.755947) (xy 103.468144 85.772) (xy 103.423 85.772) + (xy 103.423 85.752) (xy 103.403 85.752) (xy 103.403 85.498) (xy 103.423 85.498) (xy 103.423 84.64875) + (xy 103.26425 84.49) (xy 102.55 84.486928) (xy 102.425518 84.499188) (xy 102.30582 84.535498) (xy 102.195506 84.594463) + (xy 102.13501 84.644111) (xy 102.13501 84.600617) (xy 102.138686 84.563294) (xy 102.13501 84.525971) (xy 102.13501 84.525962) + (xy 102.124013 84.414309) (xy 102.080556 84.271048) (xy 102.0717 84.254479) (xy 102.009984 84.139018) (xy 101.938809 84.052292) + (xy 101.915011 84.023294) (xy 101.886014 83.999497) (xy 98.976499 81.089983) (xy 98.976499 75.907211) (xy 99.108662 75.9335) + (xy 99.371338 75.9335) (xy 99.628968 75.882254) (xy 99.819272 75.803427) (xy 99.819272 76.965994) (xy 99.729215 77.026168) + (xy 99.543475 77.211908) (xy 99.39754 77.430316) (xy 99.297018 77.672997) (xy 99.245772 77.930627) (xy 99.245772 78.193303) + (xy 99.297018 78.450933) (xy 99.39754 78.693614) (xy 99.543475 78.912022) (xy 99.729215 79.097762) (xy 99.862717 79.186965) + (xy 99.729215 79.276168) (xy 99.543475 79.461908) (xy 99.39754 79.680316) (xy 99.297018 79.922997) (xy 99.245772 80.180627) + (xy 99.245772 80.443303) (xy 99.297018 80.700933) (xy 99.39754 80.943614) (xy 99.543475 81.162022) (xy 99.729215 81.347762) + (xy 99.947623 81.493697) (xy 100.190304 81.594219) (xy 100.447934 81.645465) (xy 100.71061 81.645465) (xy 100.96824 81.594219) + (xy 101.210921 81.493697) (xy 101.429329 81.347762) (xy 101.615069 81.162022) (xy 101.643633 81.119272) (xy 101.664203 81.150057) + (xy 101.849943 81.335797) (xy 102.068351 81.481732) (xy 102.311032 81.582254) (xy 102.568662 81.6335) (xy 102.831338 81.6335) + (xy 103.088968 81.582254) (xy 103.331649 81.481732) (xy 103.550057 81.335797) (xy 103.735797 81.150057) (xy 103.881732 80.931649) + (xy 103.982254 80.688968) (xy 104.0335 80.431338) (xy 104.0335 80.168662) (xy 103.982254 79.911032) (xy 103.881732 79.668351) + (xy 103.735797 79.449943) (xy 103.550057 79.264203) (xy 103.45397 79.2) (xy 103.550057 79.135797) (xy 103.735797 78.950057) + (xy 103.881732 78.731649) (xy 103.982254 78.488968) (xy 104.0335 78.231338) (xy 104.0335 77.968662) (xy 103.982254 77.711032) + (xy 103.881732 77.468351) (xy 103.735797 77.249943) (xy 103.550057 77.064203) (xy 103.394136 76.96002) (xy 103.438475 76.905993) + (xy 103.509047 76.773964) (xy 103.552504 76.630703) (xy 103.563501 76.51905) (xy 103.563501 76.51904) (xy 103.567177 76.481717) + (xy 103.563501 76.444394) (xy 103.563501 75.69831) + ) + ) + (filled_polygon + (pts + (xy 218.227 83.998) (xy 218.247 83.998) (xy 218.247 84.252) (xy 218.227 84.252) (xy 218.227 84.272) + (xy 218.16 84.272) (xy 218.16 83.978) (xy 218.227 83.978) + ) + ) + (filled_polygon + (pts + (xy 199.227 83.998) (xy 199.247 83.998) (xy 199.247 84.252) (xy 199.227 84.252) (xy 199.227 84.272) + (xy 199.16 84.272) (xy 199.16 83.978) (xy 199.227 83.978) + ) + ) + (filled_polygon + (pts + (xy 110.210096 73.165103) (xy 109.989003 73.386196) (xy 109.959999 73.409999) (xy 109.906061 73.475723) (xy 109.865026 73.525724) + (xy 109.821944 73.606324) (xy 109.794454 73.657754) (xy 109.750997 73.801015) (xy 109.74 73.912668) (xy 109.74 73.912678) + (xy 109.736324 73.95) (xy 109.74 73.987323) (xy 109.740001 77.84) (xy 109.300072 77.84) (xy 109.300072 77.838) + (xy 109.287812 77.713518) (xy 109.251502 77.59382) (xy 109.192537 77.483506) (xy 109.113185 77.386815) (xy 109.016494 77.307463) + (xy 109.002532 77.3) (xy 109.016494 77.292537) (xy 109.113185 77.213185) (xy 109.192537 77.116494) (xy 109.251502 77.00618) + (xy 109.287812 76.886482) (xy 109.300072 76.762) (xy 109.297 76.28575) (xy 109.13825 76.127) (xy 108.027 76.127) + (xy 108.027 76.147) (xy 107.773 76.147) (xy 107.773 76.127) (xy 106.66175 76.127) (xy 106.503 76.28575) + (xy 106.499928 76.762) (xy 106.512188 76.886482) (xy 106.548498 77.00618) (xy 106.607463 77.116494) (xy 106.686815 77.213185) + (xy 106.783506 77.292537) (xy 106.797468 77.3) (xy 106.783506 77.307463) (xy 106.686815 77.386815) (xy 106.607463 77.483506) + (xy 106.548498 77.59382) (xy 106.512188 77.713518) (xy 106.499928 77.838) (xy 106.499928 79.362) (xy 106.512188 79.486482) + (xy 106.548498 79.60618) (xy 106.607463 79.716494) (xy 106.686815 79.813185) (xy 106.731674 79.85) (xy 106.686815 79.886815) + (xy 106.607463 79.983506) (xy 106.548498 80.09382) (xy 106.512188 80.213518) (xy 106.499928 80.338) (xy 106.499928 81.862) + (xy 106.505882 81.92245) (xy 106.451509 81.927805) (xy 106.284686 81.978411) (xy 106.130941 82.060589) (xy 106.029953 82.143468) + (xy 105.804952 82.368469) (xy 105.771184 82.396182) (xy 105.743471 82.42995) (xy 105.743468 82.429953) (xy 105.66059 82.53094) + (xy 105.58499 82.672379) (xy 105.58499 75.924593) (xy 105.854503 75.655081) (xy 105.883502 75.631282) (xy 105.978475 75.515557) + (xy 106.049047 75.383528) (xy 106.092504 75.240267) (xy 106.092727 75.238) (xy 106.499928 75.238) (xy 106.503 75.71425) + (xy 106.66175 75.873) (xy 107.773 75.873) (xy 107.773 74.76175) (xy 108.027 74.76175) (xy 108.027 75.873) + (xy 109.13825 75.873) (xy 109.297 75.71425) (xy 109.300072 75.238) (xy 109.287812 75.113518) (xy 109.251502 74.99382) + (xy 109.192537 74.883506) (xy 109.113185 74.786815) (xy 109.016494 74.707463) (xy 108.90618 74.648498) (xy 108.786482 74.612188) + (xy 108.662 74.599928) (xy 108.18575 74.603) (xy 108.027 74.76175) (xy 107.773 74.76175) (xy 107.61425 74.603) + (xy 107.138 74.599928) (xy 107.013518 74.612188) (xy 106.89382 74.648498) (xy 106.783506 74.707463) (xy 106.686815 74.786815) + (xy 106.607463 74.883506) (xy 106.548498 74.99382) (xy 106.512188 75.113518) (xy 106.499928 75.238) (xy 106.092727 75.238) + (xy 106.103501 75.128614) (xy 106.103501 75.128605) (xy 106.107177 75.091282) (xy 106.103501 75.053959) (xy 106.103501 74.146041) + (xy 106.107177 74.108718) (xy 106.103501 74.071396) (xy 106.103501 74.071386) (xy 106.092504 73.959733) (xy 106.049047 73.816472) + (xy 105.978475 73.684443) (xy 105.96 73.661931) (xy 105.96 70.634802) (xy 106.2062 70.881002) (xy 106.229999 70.910001) + (xy 106.345724 71.004974) (xy 106.477753 71.075546) (xy 106.621014 71.119003) (xy 106.732667 71.13) (xy 106.732675 71.13) + (xy 106.77 71.133676) (xy 106.807325 71.13) (xy 107.549317 71.13) (xy 107.633695 71.25628) (xy 107.82828 71.450865) + (xy 108.057088 71.60375) (xy 108.311325 71.709059) (xy 108.581223 71.762745) (xy 108.856407 71.762745) (xy 109.126305 71.709059) + (xy 109.380542 71.60375) (xy 109.60935 71.450865) (xy 109.803935 71.25628) (xy 109.95682 71.027472) (xy 110.062129 70.773235) + (xy 110.115815 70.503337) (xy 110.115815 70.228153) (xy 110.062129 69.958255) (xy 110.050425 69.93) (xy 110.210096 69.93) + ) + ) + (filled_polygon + (pts + (xy 142.027 79.098) (xy 142.047 79.098) (xy 142.047 79.352) (xy 142.027 79.352) (xy 142.027 79.372) + (xy 141.96 79.372) (xy 141.96 79.078) (xy 142.027 79.078) + ) + ) + (filled_polygon + (pts + (xy 161.127 76.688) (xy 161.147 76.688) (xy 161.147 76.942) (xy 161.127 76.942) (xy 161.127 76.962) + (xy 161.06 76.962) (xy 161.06 76.668) (xy 161.127 76.668) + ) + ) + (filled_polygon + (pts + (xy 114.936189 67.236001) (xy 114.959988 67.265) (xy 115.075713 67.359973) (xy 115.207742 67.430545) (xy 115.351003 67.474002) + (xy 115.462656 67.484999) (xy 115.462666 67.484999) (xy 115.499989 67.488675) (xy 115.537312 67.484999) (xy 118.349886 67.484999) + (xy 118.120583 67.828175) (xy 117.918183 68.316814) (xy 117.815 68.835551) (xy 117.815 69.364449) (xy 117.918183 69.883186) + (xy 117.923749 69.896623) (xy 117.701302 69.747989) (xy 117.392012 69.619877) (xy 117.427932 69.533158) (xy 117.485 69.24626) + (xy 117.485 68.95374) (xy 117.427932 68.666842) (xy 117.31599 68.396589) (xy 117.153475 68.153368) (xy 116.946632 67.946525) + (xy 116.703411 67.78401) (xy 116.433158 67.672068) (xy 116.14626 67.615) (xy 115.976697 67.615) (xy 115.882327 67.575911) + (xy 115.576109 67.515) (xy 115.263891 67.515) (xy 114.957673 67.575911) (xy 114.669221 67.695391) (xy 114.409621 67.86885) + (xy 114.18885 68.089621) (xy 114.015391 68.349221) (xy 113.895911 68.637673) (xy 113.835 68.943891) (xy 113.835 69.256109) + (xy 113.895911 69.562327) (xy 114.015391 69.850779) (xy 114.18885 70.110379) (xy 114.409621 70.33115) (xy 114.669221 70.504609) + (xy 114.835016 70.573283) (xy 114.797988 70.628699) (xy 114.637047 71.017245) (xy 114.555 71.429722) (xy 114.555 71.85028) + (xy 114.637047 72.262757) (xy 114.769252 72.581928) (xy 113.65 72.581928) (xy 113.525518 72.594188) (xy 113.40582 72.630498) + (xy 113.295506 72.689463) (xy 113.198815 72.768815) (xy 113.119463 72.865506) (xy 113.060498 72.97582) (xy 113.024188 73.095518) + (xy 113.011928 73.22) (xy 113.011928 73.46) (xy 112.404437 73.46) (xy 112.404437 69.51058) (xy 112.452906 69.393565) + (xy 112.484995 69.232245) (xy 112.484995 69.067765) (xy 112.452906 68.906445) (xy 112.389962 68.754484) (xy 112.298582 68.617724) + (xy 112.182276 68.501418) (xy 112.045516 68.410038) (xy 111.893555 68.347094) (xy 111.732235 68.315005) (xy 111.730095 68.315005) + (xy 111.730095 64.029906) + ) + ) + (filled_polygon + (pts + (xy 95.56 69.01887) (xy 95.56 68.926622) (xy 95.652248 68.926622) + ) + ) + (filled_polygon + (pts + (xy 96.827 68.67262) (xy 96.847 68.67262) (xy 96.847 68.844808) (xy 96.553 68.844808) (xy 96.553 68.67262) + (xy 96.573 68.67262) (xy 96.573 68.65262) (xy 96.827 68.65262) + ) + ) + (filled_polygon + (pts + (xy 198.228698 59.372012) (xy 198.284017 59.394926) (xy 198.248815 59.423815) (xy 198.169463 59.520506) (xy 198.110498 59.63082) + (xy 198.074188 59.750518) (xy 198.061928 59.875) (xy 198.061928 60.875) (xy 198.074188 60.999482) (xy 198.110498 61.11918) + (xy 198.169463 61.229494) (xy 198.186292 61.25) (xy 198.169463 61.270506) (xy 198.110498 61.38082) (xy 198.074188 61.500518) + (xy 198.061928 61.625) (xy 198.065 61.83925) (xy 198.22375 61.998) (xy 199.573 61.998) (xy 199.573 61.978) + (xy 199.827 61.978) (xy 199.827 61.998) (xy 201.023872 61.998) (xy 201.15644 62.052911) (xy 201.31776 62.085) + (xy 201.48224 62.085) (xy 201.64356 62.052911) (xy 201.795521 61.989967) (xy 201.932281 61.898587) (xy 201.935511 61.895357) + (xy 201.935511 64.777042) (xy 201.93123 64.820511) (xy 201.935511 64.86398) (xy 201.935511 64.863987) (xy 201.946114 64.971638) + (xy 201.948316 64.994001) (xy 201.960753 65.034999) (xy 201.998922 65.160823) (xy 202.0811 65.314569) (xy 202.191694 65.449328) + (xy 202.225467 65.477045) (xy 205.29 68.541579) (xy 205.29 68.815) (xy 202.134801 68.815) (xy 202.856923 68.092878) + (xy 202.960521 68.049967) (xy 203.097281 67.958587) (xy 203.213587 67.842281) (xy 203.304967 67.705521) (xy 203.367911 67.55356) + (xy 203.4 67.39224) (xy 203.4 67.22776) (xy 203.367911 67.06644) (xy 203.304967 66.914479) (xy 203.213587 66.777719) + (xy 203.097281 66.661413) (xy 202.960521 66.570033) (xy 202.80856 66.507089) (xy 202.64724 66.475) (xy 202.48276 66.475) + (xy 202.32144 66.507089) (xy 202.169479 66.570033) (xy 202.032719 66.661413) (xy 201.916413 66.777719) (xy 201.825033 66.914479) + (xy 201.782122 67.018077) (xy 201.210199 67.59) (xy 200.997157 67.59) (xy 200.89356 67.547089) (xy 200.73224 67.515) + (xy 200.56776 67.515) (xy 200.417981 67.544793) (xy 200.430537 67.529494) (xy 200.489502 67.41918) (xy 200.50056 67.382726) + (xy 200.507747 67.380546) (xy 200.639776 67.309974) (xy 200.755501 67.215001) (xy 200.779303 67.185998) (xy 201.161007 66.804295) + (xy 201.190005 66.780497) (xy 201.284978 66.664772) (xy 201.35555 66.532743) (xy 201.389282 66.421543) (xy 201.389971 66.420511) + (xy 201.452915 66.26855) (xy 201.485004 66.10723) (xy 201.485004 65.94275) (xy 201.452915 65.78143) (xy 201.389971 65.629469) + (xy 201.298591 65.492709) (xy 201.182285 65.376403) (xy 201.045525 65.285023) (xy 200.893564 65.222079) (xy 200.732244 65.18999) + (xy 200.567764 65.18999) (xy 200.52312 65.19887) (xy 200.37625 65.052) (xy 199.227 65.052) (xy 199.227 65.072) + (xy 199.16 65.072) (xy 199.16 64.778) (xy 199.227 64.778) (xy 199.227 64.798) (xy 200.37625 64.798) + (xy 200.535 64.63925) (xy 200.538072 64.425) (xy 200.525812 64.300518) (xy 200.489502 64.18082) (xy 200.430537 64.070506) + (xy 200.351185 63.973815) (xy 200.254494 63.894463) (xy 200.14418 63.835498) (xy 200.024482 63.799188) (xy 199.9 63.786928) + (xy 199.38575 63.79) (xy 199.227002 63.948748) (xy 199.227002 63.79) (xy 199.16 63.79) (xy 199.16 63.584877) + (xy 199.163435 63.55) (xy 199.149727 63.410816) (xy 199.109128 63.27698) (xy 199.100773 63.261348) (xy 199.41425 63.26) + (xy 199.573 63.10125) (xy 199.573 62.252) (xy 199.827 62.252) (xy 199.827 63.10125) (xy 199.98575 63.26) + (xy 200.7 63.263072) (xy 200.824482 63.250812) (xy 200.94418 63.214502) (xy 201.054494 63.155537) (xy 201.151185 63.076185) + (xy 201.230537 62.979494) (xy 201.289502 62.86918) (xy 201.325812 62.749482) (xy 201.338072 62.625) (xy 201.335 62.41075) + (xy 201.17625 62.252) (xy 199.827 62.252) (xy 199.573 62.252) (xy 198.22375 62.252) (xy 198.065 62.41075) + (xy 198.061928 62.625) (xy 198.074188 62.749482) (xy 198.101646 62.84) (xy 197.956893 62.84) (xy 197.980547 62.795746) + (xy 197.98714 62.77401) (xy 198.024004 62.652485) (xy 198.035001 62.540832) (xy 198.035001 62.540822) (xy 198.038677 62.503499) + (xy 198.035001 62.466176) (xy 198.035001 59.242588) + ) + ) + (filled_polygon + (pts + (xy 110.210096 68.299761) (xy 110.201534 68.301464) (xy 110.049573 68.364408) (xy 109.991807 68.403006) (xy 110.062129 68.233235) + (xy 110.115815 67.963337) (xy 110.115815 67.688153) (xy 110.062129 67.418255) (xy 109.95682 67.164018) (xy 109.803935 66.93521) + (xy 109.60935 66.740625) (xy 109.380542 66.58774) (xy 109.3033 66.555745) (xy 109.380542 66.52375) (xy 109.60935 66.370865) + (xy 109.803935 66.17628) (xy 109.95682 65.947472) (xy 110.062129 65.693235) (xy 110.115815 65.423337) (xy 110.115815 65.148153) + (xy 110.062129 64.878255) (xy 109.95682 64.624018) (xy 109.803935 64.39521) (xy 109.60935 64.200625) (xy 109.380542 64.04774) + (xy 109.3033 64.015745) (xy 109.380542 63.98375) (xy 109.60935 63.830865) (xy 109.803935 63.63628) (xy 109.95682 63.407472) + (xy 110.062129 63.153235) (xy 110.115815 62.883337) (xy 110.115815 62.608153) (xy 110.062129 62.338255) (xy 109.95682 62.084018) + (xy 109.803935 61.85521) (xy 109.60935 61.660625) (xy 109.380542 61.50774) (xy 109.3033 61.475745) (xy 109.380542 61.44375) + (xy 109.60935 61.290865) (xy 109.803935 61.09628) (xy 109.95682 60.867472) (xy 110.062129 60.613235) (xy 110.115815 60.343337) + (xy 110.115815 60.068153) (xy 110.062129 59.798255) (xy 109.95682 59.544018) (xy 109.803935 59.31521) (xy 109.60935 59.120625) + (xy 109.380542 58.96774) (xy 109.3033 58.935745) (xy 109.380542 58.90375) (xy 109.60935 58.750865) (xy 109.803935 58.55628) + (xy 109.95682 58.327472) (xy 110.062129 58.073235) (xy 110.115815 57.803337) (xy 110.115815 57.528153) (xy 110.062129 57.258255) + (xy 109.95682 57.004018) (xy 109.803935 56.77521) (xy 109.60935 56.580625) (xy 109.380542 56.42774) (xy 109.3033 56.395745) + (xy 109.380542 56.36375) (xy 109.60935 56.210865) (xy 109.803935 56.01628) (xy 109.95682 55.787472) (xy 110.062129 55.533235) + (xy 110.115815 55.263337) (xy 110.115815 54.988153) (xy 110.062129 54.718255) (xy 109.95682 54.464018) (xy 109.803935 54.23521) + (xy 109.60935 54.040625) (xy 109.380542 53.88774) (xy 109.3033 53.855745) (xy 109.380542 53.82375) (xy 109.60935 53.670865) + (xy 109.803935 53.47628) (xy 109.95682 53.247472) (xy 110.062129 52.993235) (xy 110.115815 52.723337) (xy 110.115815 52.448153) + (xy 110.062129 52.178255) (xy 109.95682 51.924018) (xy 109.803935 51.69521) (xy 109.60935 51.500625) (xy 109.380542 51.34774) + (xy 109.308872 51.318053) (xy 109.321838 51.313381) (xy 109.437795 51.251401) (xy 109.504775 51.01131) (xy 108.718815 50.22535) + (xy 108.704673 50.239493) (xy 108.525068 50.059888) (xy 108.53921 50.045745) (xy 108.525068 50.031603) (xy 108.704673 49.851998) + (xy 108.718815 49.86614) (xy 108.732958 49.851998) (xy 108.912563 50.031603) (xy 108.89842 50.045745) (xy 109.68438 50.831705) + (xy 109.924471 50.764725) (xy 110.041571 50.515697) (xy 110.107838 50.24861) (xy 110.120725 49.973728) (xy 110.079737 49.701612) + (xy 110.005347 49.495163) (xy 110.045073 49.462561) (xy 110.07279 49.428788) (xy 110.210095 49.291483) + ) + ) + (filled_polygon + (pts + (xy 102.163998 40.490556) (xy 102.135 40.514354) (xy 102.111202 40.543352) (xy 102.111201 40.543353) (xy 102.040026 40.630079) + (xy 101.969454 40.762109) (xy 101.93433 40.877901) (xy 101.925998 40.905369) (xy 101.915198 41.015027) (xy 101.911324 41.054355) + (xy 101.915001 41.091688) (xy 101.915 53.467114) (xy 101.848587 53.367719) (xy 101.732281 53.251413) (xy 101.595521 53.160033) + (xy 101.44356 53.097089) (xy 101.285008 53.065551) (xy 101.285008 50.089218) (xy 101.289289 50.045752) (xy 101.285008 50.002286) + (xy 101.285008 50.002276) (xy 101.272203 49.872263) (xy 101.221597 49.70544) (xy 101.139419 49.551694) (xy 101.028825 49.416936) + (xy 100.995052 49.389219) (xy 100.995046 49.389213) (xy 100.894059 49.306335) (xy 100.740313 49.224157) (xy 100.57349 49.17355) + (xy 100.4 49.156464) (xy 100.22651 49.17355) (xy 100.059687 49.224157) (xy 99.905941 49.306335) (xy 99.771183 49.416928) + (xy 99.66059 49.551686) (xy 99.578412 49.705432) (xy 99.527805 49.872255) (xy 99.510719 50.045745) (xy 99.515009 50.089305) + (xy 99.515008 67.844048) (xy 98.976499 67.844048) (xy 98.976499 53.481144) (xy 99.025252 53.432391) (xy 99.054256 53.408588) + (xy 99.149229 53.292863) (xy 99.219801 53.160834) (xy 99.229454 53.129011) (xy 99.263258 53.017573) (xy 99.270768 52.941319) + (xy 99.317166 52.829305) (xy 99.349255 52.667985) (xy 99.349255 52.503505) (xy 99.317166 52.342185) (xy 99.254222 52.190224) + (xy 99.162842 52.053464) (xy 99.046536 51.937158) (xy 98.909776 51.845778) (xy 98.757815 51.782834) (xy 98.596495 51.750745) + (xy 98.432015 51.750745) (xy 98.270695 51.782834) (xy 98.118734 51.845778) (xy 97.981974 51.937158) (xy 97.865668 52.053464) + (xy 97.774288 52.190224) (xy 97.711344 52.342185) (xy 97.679255 52.503505) (xy 97.679255 52.624079) (xy 97.676498 52.626342) + (xy 97.62485 52.689276) (xy 97.581525 52.742067) (xy 97.534895 52.829305) (xy 97.510953 52.874097) (xy 97.467496 53.017358) + (xy 97.456499 53.129011) (xy 97.456499 53.129021) (xy 97.452823 53.166343) (xy 97.456499 53.203665) (xy 97.4565 67.874666) + (xy 97.395982 67.856308) (xy 97.2715 67.844048) (xy 96.98575 67.84712) (xy 96.870155 67.962715) (xy 96.885 67.888087) + (xy 96.885 67.723607) (xy 96.852911 67.562287) (xy 96.81 67.45869) (xy 96.81 51.83037) (xy 96.839967 51.785521) + (xy 96.902911 51.63356) (xy 96.935 51.47224) (xy 96.935 51.30776) (xy 96.902911 51.14644) (xy 96.839967 50.994479) + (xy 96.748587 50.857719) (xy 96.632281 50.741413) (xy 96.495521 50.650033) (xy 96.34356 50.587089) (xy 96.18224 50.555) + (xy 96.01776 50.555) (xy 95.85644 50.587089) (xy 95.704479 50.650033) (xy 95.567719 50.741413) (xy 95.56 50.749132) + (xy 95.56 44.896884) (xy 95.632281 44.848587) (xy 95.748587 44.732281) (xy 95.839967 44.595521) (xy 95.902911 44.44356) + (xy 95.935 44.28224) (xy 95.935 44.11776) (xy 95.902911 43.95644) (xy 95.839967 43.804479) (xy 95.748587 43.667719) + (xy 95.632281 43.551413) (xy 95.495521 43.460033) (xy 95.34356 43.397089) (xy 95.18224 43.365) (xy 95.01776 43.365) + (xy 94.85644 43.397089) (xy 94.704479 43.460033) (xy 94.567719 43.551413) (xy 94.451413 43.667719) (xy 94.360033 43.804479) + (xy 94.317121 43.908078) (xy 94.289003 43.936196) (xy 94.259999 43.959999) (xy 94.255198 43.96585) (xy 94.197795 43.760089) + (xy 94.062055 43.69626) (xy 94.140542 43.66375) (xy 94.36935 43.510865) (xy 94.563935 43.31628) (xy 94.71682 43.087472) + (xy 94.822129 42.833235) (xy 94.875815 42.563337) (xy 94.875815 42.288153) (xy 94.822129 42.018255) (xy 94.71682 41.764018) + (xy 94.563935 41.53521) (xy 94.36935 41.340625) (xy 94.140542 41.18774) (xy 93.886305 41.082431) (xy 93.616407 41.028745) + (xy 93.564337 41.028745) (xy 93.523314 40.82251) (xy 93.418005 40.568273) (xy 93.26512 40.339465) (xy 93.070535 40.14488) + (xy 92.841727 39.991995) (xy 92.58749 39.886686) (xy 92.317592 39.833) (xy 92.042408 39.833) (xy 91.77251 39.886686) + (xy 91.518273 39.991995) (xy 91.289465 40.14488) (xy 91.09488 40.339465) (xy 90.941995 40.568273) (xy 90.836686 40.82251) + (xy 90.783 41.092408) (xy 90.783 41.367592) (xy 90.836686 41.63749) (xy 90.941995 41.891727) (xy 91.09488 42.120535) + (xy 91.289465 42.31512) (xy 91.518273 42.468005) (xy 91.595515 42.5) (xy 91.518273 42.531995) (xy 91.289465 42.68488) + (xy 91.09488 42.879465) (xy 90.941995 43.108273) (xy 90.836686 43.36251) (xy 90.783 43.632408) (xy 90.783 43.907592) + (xy 90.836686 44.17749) (xy 90.941995 44.431727) (xy 91.09488 44.660535) (xy 91.289465 44.85512) (xy 91.518273 45.008005) + (xy 91.589943 45.037692) (xy 91.576977 45.042364) (xy 91.46102 45.104344) (xy 91.39404 45.344435) (xy 92.18 46.130395) + (xy 92.96596 45.344435) (xy 92.956048 45.308907) (xy 93.29921 44.965745) (xy 93.285068 44.951603) (xy 93.464673 44.771998) + (xy 93.478815 44.78614) (xy 93.492958 44.771998) (xy 93.672563 44.951603) (xy 93.65842 44.965745) (xy 93.672563 44.979888) + (xy 93.492958 45.159493) (xy 93.478815 45.14535) (xy 92.692855 45.93131) (xy 92.702767 45.966838) (xy 92.359605 46.31) + (xy 92.373748 46.324143) (xy 92.194143 46.503748) (xy 92.18 46.489605) (xy 92.165858 46.503748) (xy 91.986253 46.324143) + (xy 92.000395 46.31) (xy 91.214435 45.52404) (xy 90.974344 45.59102) (xy 90.857244 45.840048) (xy 90.790977 46.107135) + (xy 90.77809 46.382017) (xy 90.819078 46.654133) (xy 90.912364 46.913023) (xy 90.974344 47.02898) (xy 91.214433 47.095959) + (xy 91.098023 47.212369) (xy 91.113917 47.228263) (xy 91.094444 47.251991) (xy 88.959058 49.387379) (xy 88.958857 38.511863) + (xy 88.971894 38.382509) (xy 88.998593 38.296493) (xy 89.041067 38.218238) (xy 89.097851 38.149414) (xy 89.16667 38.092633) + (xy 89.244936 38.05015) (xy 89.33096 38.023445) (xy 89.473606 38.009063) (xy 105.261763 37.392791) + ) + ) + (filled_polygon + (pts + (xy 168.386928 62.525) (xy 168.399188 62.649482) (xy 168.421668 62.723587) (xy 168.352441 62.760589) (xy 168.333363 62.776246) + (xy 168.251453 62.843468) (xy 168.251451 62.84347) (xy 168.217683 62.871183) (xy 168.18997 62.904951) (xy 166.654951 64.439971) + (xy 166.621184 64.467683) (xy 166.593471 64.501451) (xy 166.593468 64.501454) (xy 166.51059 64.602441) (xy 166.428412 64.756187) + (xy 166.377805 64.92301) (xy 166.367078 65.031928) (xy 164.956887 65.031928) (xy 165.084609 64.840779) (xy 165.204089 64.552327) + (xy 165.265 64.246109) (xy 165.265 63.933891) (xy 165.204089 63.627673) (xy 165.084609 63.339221) (xy 164.91115 63.079621) + (xy 164.690379 62.85885) (xy 164.430779 62.685391) (xy 164.142327 62.565911) (xy 163.836109 62.505) (xy 163.523891 62.505) + (xy 163.217673 62.565911) (xy 163.123303 62.605) (xy 162.95374 62.605) (xy 162.666842 62.662068) (xy 162.396589 62.77401) + (xy 162.153368 62.936525) (xy 161.946525 63.143368) (xy 161.78401 63.386589) (xy 161.672068 63.656842) (xy 161.615 63.94374) + (xy 161.615 64.23626) (xy 161.672068 64.523158) (xy 161.707988 64.609876) (xy 161.398698 64.737988) (xy 161.176252 64.886622) + (xy 161.181817 64.873186) (xy 161.285 64.354449) (xy 161.285 63.825551) (xy 161.181817 63.306814) (xy 160.979417 62.818175) + (xy 160.685576 62.378412) (xy 160.535164 62.228) (xy 168.386928 62.228) + ) + ) + (filled_polygon + (pts + (xy 117.907753 40.944454) (xy 117.775724 41.015026) (xy 117.775722 41.015027) (xy 117.775723 41.015027) (xy 117.688996 41.086201) + (xy 117.688992 41.086205) (xy 117.659999 41.109999) (xy 117.636205 41.138992) (xy 116.108077 42.667121) (xy 116.004479 42.710033) + (xy 115.867719 42.801413) (xy 115.751413 42.917719) (xy 115.660033 43.054479) (xy 115.597089 43.20644) (xy 115.565 43.36776) + (xy 115.565 43.53224) (xy 115.597089 43.69356) (xy 115.603299 43.708552) (xy 115.505941 43.76059) (xy 115.371183 43.871183) + (xy 115.26059 44.005941) (xy 115.178412 44.159687) (xy 115.127805 44.32651) (xy 115.110719 44.5) (xy 115.127805 44.67349) + (xy 115.178412 44.840313) (xy 115.26059 44.994059) (xy 115.343468 45.095046) (xy 116.21847 45.970049) (xy 116.246183 46.003817) + (xy 116.279951 46.03153) (xy 116.279953 46.031532) (xy 116.368054 46.103835) (xy 116.380941 46.114411) (xy 116.534687 46.196589) + (xy 116.70151 46.247195) (xy 116.791243 46.256033) (xy 116.848815 46.326185) (xy 116.945506 46.405537) (xy 117.05582 46.464502) + (xy 117.175518 46.500812) (xy 117.3 46.513072) (xy 118.04 46.513072) (xy 118.04 46.715123) (xy 118.036565 46.75) + (xy 118.050273 46.889184) (xy 118.090872 47.02302) (xy 118.1568 47.146363) (xy 118.245525 47.254475) (xy 118.343645 47.335) + (xy 118.353637 47.3432) (xy 118.47698 47.409128) (xy 118.610816 47.449727) (xy 118.75 47.463435) (xy 118.784877 47.46) + (xy 119.615858 47.46) (xy 119.228175 47.620583) (xy 118.788412 47.914424) (xy 118.414424 48.288412) (xy 118.120583 48.728175) + (xy 117.918183 49.216814) (xy 117.815 49.735551) (xy 117.815 50.264449) (xy 117.918183 50.783186) (xy 117.923749 50.796623) + (xy 117.701302 50.647989) (xy 117.392012 50.519877) (xy 117.427932 50.433158) (xy 117.485 50.14626) (xy 117.485 49.85374) + (xy 117.427932 49.566842) (xy 117.31599 49.296589) (xy 117.153475 49.053368) (xy 116.946632 48.846525) (xy 116.703411 48.68401) + (xy 116.433158 48.572068) (xy 116.14626 48.515) (xy 115.976697 48.515) (xy 115.882327 48.475911) (xy 115.576109 48.415) + (xy 115.263891 48.415) (xy 114.957673 48.475911) (xy 114.669221 48.595391) (xy 114.409621 48.76885) (xy 114.18885 48.989621) + (xy 114.015391 49.249221) (xy 113.895911 49.537673) (xy 113.835 49.843891) (xy 113.835 50.156109) (xy 113.895911 50.462327) + (xy 114.015391 50.750779) (xy 114.18885 51.010379) (xy 114.409621 51.23115) (xy 114.669221 51.404609) (xy 114.835016 51.473283) + (xy 114.797988 51.528699) (xy 114.637047 51.917245) (xy 114.555 52.329722) (xy 114.555 52.75028) (xy 114.637047 53.162757) + (xy 114.769252 53.481928) (xy 113.65 53.481928) (xy 113.525518 53.494188) (xy 113.40582 53.530498) (xy 113.295506 53.589463) + (xy 113.198815 53.668815) (xy 113.119463 53.765506) (xy 113.060498 53.87582) (xy 113.024188 53.995518) (xy 113.011928 54.12) + (xy 113.011928 56.12) (xy 113.024188 56.244482) (xy 113.060498 56.36418) (xy 113.119463 56.474494) (xy 113.198815 56.571185) + (xy 113.295506 56.650537) (xy 113.40582 56.709502) (xy 113.525518 56.745812) (xy 113.65 56.758072) (xy 113.9531 56.758072) + (xy 114.010033 56.895521) (xy 114.101413 57.032281) (xy 114.217719 57.148587) (xy 114.354479 57.239967) (xy 114.50644 57.302911) + (xy 114.66776 57.335) (xy 114.83224 57.335) (xy 114.99356 57.302911) (xy 115.040862 57.283318) (xy 115.036197 57.289002) + (xy 114.713988 57.611211) (xy 114.68499 57.635009) (xy 114.661192 57.664007) (xy 114.661191 57.664008) (xy 114.590016 57.750734) + (xy 114.519444 57.882764) (xy 114.497367 57.955546) (xy 114.475988 58.026024) (xy 114.468415 58.102911) (xy 114.461314 58.17501) + (xy 114.464991 58.212342) (xy 114.46499 64.437667) (xy 114.461314 64.47499) (xy 114.46499 64.512312) (xy 114.46499 64.512322) + (xy 114.475987 64.623975) (xy 114.476954 64.627162) (xy 112.357869 62.508078) (xy 112.314957 62.404479) (xy 112.223577 62.267719) + (xy 112.107271 62.151413) (xy 111.970511 62.060033) (xy 111.81855 61.997089) (xy 111.730095 61.979494) (xy 111.730095 59.781674) + (xy 112.404953 60.456532) (xy 112.50594 60.53941) (xy 112.659686 60.621588) (xy 112.826509 60.672194) (xy 112.999999 60.689281) + (xy 113.173489 60.672194) (xy 113.340313 60.621588) (xy 113.494058 60.53941) (xy 113.628817 60.428817) (xy 113.73941 60.294058) + (xy 113.821588 60.140313) (xy 113.872194 59.973489) (xy 113.889281 59.799999) (xy 113.872194 59.626509) (xy 113.821588 59.459686) + (xy 113.73941 59.30594) (xy 113.656532 59.204953) (xy 112.535 58.083422) (xy 112.535 46.886993) (xy 112.546588 46.865313) + (xy 112.597194 46.69849) (xy 112.614281 46.525001) (xy 112.597194 46.35151) (xy 112.546588 46.184687) (xy 112.46441 46.030941) + (xy 112.353817 45.896183) (xy 112.219059 45.78559) (xy 112.065313 45.703412) (xy 111.89849 45.652806) (xy 111.730095 45.636221) + (xy 111.730095 44.71435) (xy 111.733771 44.677025) (xy 111.730095 44.6397) (xy 111.730095 44.639692) (xy 111.719098 44.528039) + (xy 111.675641 44.384778) (xy 111.605069 44.252749) (xy 111.510096 44.137024) (xy 111.481099 44.113227) (xy 110.085187 42.717315) + (xy 110.115815 42.563337) (xy 110.115815 42.288153) (xy 110.062129 42.018255) (xy 109.95682 41.764018) (xy 109.803935 41.53521) + (xy 109.60935 41.340625) (xy 109.380542 41.18774) (xy 109.126305 41.082431) (xy 108.856407 41.028745) (xy 108.804337 41.028745) + (xy 108.780719 40.910011) (xy 118.021298 40.910011) + ) + ) + (filled_polygon + (pts + (xy 123.027 62.598) (xy 123.047 62.598) (xy 123.047 62.852) (xy 123.027 62.852) (xy 123.027 62.872) + (xy 122.96 62.872) (xy 122.96 62.578) (xy 123.027 62.578) + ) + ) + (filled_polygon + (pts + (xy 121.074188 59.249482) (xy 121.110498 59.36918) (xy 121.169463 59.479494) (xy 121.186292 59.5) (xy 121.169463 59.520506) + (xy 121.110498 59.63082) (xy 121.074188 59.750518) (xy 121.061928 59.875) (xy 121.065 60.08925) (xy 121.22375 60.248) + (xy 122.573 60.248) (xy 122.573 60.228) (xy 122.827 60.228) (xy 122.827 60.248) (xy 124.17625 60.248) + (xy 124.192372 60.231878) (xy 124.204479 60.239967) (xy 124.35644 60.302911) (xy 124.51776 60.335) (xy 124.68224 60.335) + (xy 124.84356 60.302911) (xy 124.877316 60.288929) (xy 125.140001 60.551615) (xy 125.14 62.809132) (xy 125.132281 62.801413) + (xy 124.995521 62.710033) (xy 124.84356 62.647089) (xy 124.68224 62.615) (xy 124.51776 62.615) (xy 124.35644 62.647089) + (xy 124.335 62.65597) (xy 124.335 62.597998) (xy 124.176252 62.597998) (xy 124.335 62.43925) (xy 124.338072 62.225) + (xy 124.325812 62.100518) (xy 124.289502 61.98082) (xy 124.230537 61.870506) (xy 124.151185 61.773815) (xy 124.054494 61.694463) + (xy 123.94418 61.635498) (xy 123.824482 61.599188) (xy 123.7 61.586928) (xy 123.18575 61.59) (xy 123.027002 61.748748) + (xy 123.027002 61.59) (xy 122.96 61.59) (xy 122.96 61.48425) (xy 122.98575 61.51) (xy 123.7 61.513072) + (xy 123.824482 61.500812) (xy 123.94418 61.464502) (xy 124.054494 61.405537) (xy 124.151185 61.326185) (xy 124.230537 61.229494) + (xy 124.289502 61.11918) (xy 124.325812 60.999482) (xy 124.338072 60.875) (xy 124.335 60.66075) (xy 124.17625 60.502) + (xy 122.827 60.502) (xy 122.827 60.522) (xy 122.573 60.522) (xy 122.573 60.502) (xy 121.22375 60.502) + (xy 121.08575 60.64) (xy 119.938072 60.64) (xy 119.938072 60.376727) (xy 121.073393 59.241407) + ) + ) + (filled_polygon + (pts + (xy 170.540001 60.79358) (xy 170.540001 60.934983) (xy 170.505537 60.870506) (xy 170.426185 60.773815) (xy 170.329494 60.694463) + (xy 170.21918 60.635498) (xy 170.099482 60.599188) (xy 169.975 60.586928) (xy 169.025 60.586928) (xy 168.900518 60.599188) + (xy 168.78082 60.635498) (xy 168.670506 60.694463) (xy 168.654011 60.708) (xy 165.071576 60.708) (xy 167.762999 58.016578) + ) + ) + (filled_polygon + (pts + (xy 142.027 60.098) (xy 142.047 60.098) (xy 142.047 60.352) (xy 142.027 60.352) (xy 142.027 60.372) + (xy 141.96 60.372) (xy 141.96 60.078) (xy 142.027 60.078) + ) + ) + (filled_polygon + (pts + (xy 164.967125 57.081921) (xy 165.010036 57.185518) (xy 165.101416 57.322278) (xy 165.217722 57.438584) (xy 165.354482 57.529964) + (xy 165.506443 57.592908) (xy 165.654133 57.622286) (xy 163.27142 60.005) (xy 162.512202 60.005) (xy 162.536004 59.975997) + (xy 162.810998 59.701003) (xy 162.840001 59.677201) (xy 162.934974 59.561476) (xy 163.005546 59.429447) (xy 163.049003 59.286186) + (xy 163.06 59.174533) (xy 163.06 59.174524) (xy 163.063676 59.137201) (xy 163.06 59.099878) (xy 163.06 59.087157) + (xy 163.102911 58.98356) (xy 163.135 58.82224) (xy 163.135 58.65776) (xy 163.102911 58.49644) (xy 163.039967 58.344479) + (xy 162.948587 58.207719) (xy 162.832281 58.091413) (xy 162.695521 58.000033) (xy 162.54356 57.937089) (xy 162.38224 57.905) + (xy 162.33925 57.905) (xy 162.27625 57.842) (xy 161.127 57.842) (xy 161.127 57.862) (xy 161.06 57.862) + (xy 161.06 57.568) (xy 161.127 57.568) (xy 161.127 57.588) (xy 162.27625 57.588) (xy 162.435 57.42925) + (xy 162.438072 57.215) (xy 162.425812 57.090518) (xy 162.389502 56.97082) (xy 162.330537 56.860506) (xy 162.251185 56.763815) + (xy 162.154494 56.684463) (xy 162.04418 56.625498) (xy 161.924482 56.589188) (xy 161.8 56.576928) (xy 161.28575 56.58) + (xy 161.127002 56.738748) (xy 161.127002 56.58) (xy 161.06 56.58) (xy 161.06 56.365677) (xy 161.063435 56.3308) + (xy 161.049727 56.191616) (xy 161.009128 56.05778) (xy 160.9432 55.934437) (xy 160.854475 55.826325) (xy 160.826141 55.803072) + (xy 161.7 55.803072) (xy 161.824482 55.790812) (xy 161.94418 55.754502) (xy 162.054494 55.695537) (xy 162.151185 55.616185) + (xy 162.230537 55.519494) (xy 162.289502 55.40918) (xy 162.306939 55.351697) (xy 162.40644 55.392911) (xy 162.56776 55.425) + (xy 162.73224 55.425) (xy 162.89356 55.392911) (xy 162.997157 55.35) (xy 163.235205 55.35) + ) + ) + (filled_polygon + (pts + (xy 205.115 47.543476) (xy 205.115001 47.543486) (xy 205.115 53.401627) (xy 205.09418 53.390498) (xy 204.974482 53.354188) + (xy 204.85 53.341928) (xy 204.623127 53.341928) (xy 204.635 53.28224) (xy 204.635 53.11776) (xy 204.602911 52.95644) + (xy 204.539967 52.804479) (xy 204.448587 52.667719) (xy 204.332281 52.551413) (xy 204.195521 52.460033) (xy 204.04356 52.397089) + (xy 203.88224 52.365) (xy 203.71776 52.365) (xy 203.55644 52.397089) (xy 203.404479 52.460033) (xy 203.365 52.486412) + (xy 203.365 52.243891) (xy 203.304089 51.937673) (xy 203.184609 51.649221) (xy 203.01115 51.389621) (xy 202.790379 51.16885) + (xy 202.530779 50.995391) (xy 202.242327 50.875911) (xy 201.936109 50.815) (xy 201.623891 50.815) (xy 201.317673 50.875911) + (xy 201.223303 50.915) (xy 201.05374 50.915) (xy 200.766842 50.972068) (xy 200.76 50.974902) (xy 200.76 48.399322) + (xy 200.763676 48.361999) (xy 200.76 48.324676) (xy 200.76 48.324667) (xy 200.749863 48.221741) (xy 200.819001 48.165001) + (xy 200.842804 48.135997) (xy 201.260997 47.717804) (xy 201.290001 47.694001) (xy 201.384974 47.578276) (xy 201.409559 47.532281) + (xy 201.453438 47.45019) (xy 201.489967 47.395521) (xy 201.552911 47.24356) (xy 201.585 47.08224) (xy 201.585 46.91776) + (xy 201.552911 46.75644) (xy 201.489967 46.604479) (xy 201.398587 46.467719) (xy 201.282281 46.351413) (xy 201.145521 46.260033) + (xy 200.99356 46.197089) (xy 200.83224 46.165) (xy 200.66776 46.165) (xy 200.50644 46.197089) (xy 200.446264 46.222014) + (xy 200.37625 46.152) (xy 199.227 46.152) (xy 199.227 46.172) (xy 199.16 46.172) (xy 199.16 45.878) + (xy 199.227 45.878) (xy 199.227 45.898) (xy 200.37625 45.898) (xy 200.535 45.73925) (xy 200.538072 45.525) + (xy 200.525812 45.400518) (xy 200.489502 45.28082) (xy 200.430537 45.170506) (xy 200.351185 45.073815) (xy 200.254494 44.994463) + (xy 200.14418 44.935498) (xy 200.024482 44.899188) (xy 199.9 44.886928) (xy 199.38575 44.89) (xy 199.227002 45.048748) + (xy 199.227002 44.89) (xy 199.16 44.89) (xy 199.16 44.684877) (xy 199.163435 44.65) (xy 199.149727 44.510816) + (xy 199.109128 44.37698) (xy 199.092783 44.3464) (xy 205.115001 44.3464) + ) + ) + (filled_polygon + (pts + (xy 166.865001 52.905) (xy 165.682887 52.905) (xy 165.782281 52.838587) (xy 165.898587 52.722281) (xy 165.989967 52.585521) + (xy 166.052911 52.43356) (xy 166.085 52.27224) (xy 166.085 52.10776) (xy 166.052911 51.94644) (xy 166.01 51.842843) + (xy 166.01 49.218072) (xy 166.75 49.218072) (xy 166.865001 49.206746) + ) + ) + (filled_polygon + (pts + (xy 199.240001 51.51586) (xy 199.079417 51.128175) (xy 198.785576 50.688412) (xy 198.411588 50.314424) (xy 197.971825 50.020583) + (xy 197.584142 49.86) (xy 198.415123 49.86) (xy 198.45 49.863435) (xy 198.484877 49.86) (xy 198.589184 49.849727) + (xy 198.72302 49.809128) (xy 198.846363 49.7432) (xy 198.954475 49.654475) (xy 199.0432 49.546363) (xy 199.109128 49.42302) + (xy 199.149727 49.289184) (xy 199.163435 49.15) (xy 199.16 49.115123) (xy 199.16 48.913072) (xy 199.24 48.913072) + ) + ) + (filled_polygon + (pts + (xy 210.464999 47.30653) (xy 210.460718 47.349999) (xy 210.464999 47.393468) (xy 210.464999 47.393475) (xy 210.475589 47.500997) + (xy 210.477804 47.523489) (xy 210.490032 47.563799) (xy 210.52841 47.690311) (xy 210.610588 47.844057) (xy 210.721182 47.978816) + (xy 210.754955 48.006533) (xy 211.118466 48.370044) (xy 211.146183 48.403817) (xy 211.280941 48.514411) (xy 211.434687 48.596589) + (xy 211.60151 48.647195) (xy 211.731523 48.66) (xy 211.731533 48.66) (xy 211.774999 48.664281) (xy 211.818465 48.66) + (xy 212.037036 48.66) (xy 211.997089 48.75644) (xy 211.965 48.91776) (xy 211.965 49.08224) (xy 211.997089 49.24356) + (xy 212.040001 49.347159) (xy 212.04 50.452843) (xy 211.997089 50.55644) (xy 211.965 50.71776) (xy 211.965 50.88224) + (xy 211.997089 51.04356) (xy 212.017836 51.093649) (xy 212.003411 51.08401) (xy 211.733158 50.972068) (xy 211.44626 50.915) + (xy 211.276697 50.915) (xy 211.182327 50.875911) (xy 210.876109 50.815) (xy 210.563891 50.815) (xy 210.257673 50.875911) + (xy 210.01 50.9785) (xy 210.01 47.009587) (xy 210.04356 47.002911) (xy 210.195521 46.939967) (xy 210.332281 46.848587) + (xy 210.448587 46.732281) (xy 210.464999 46.707719) + ) + ) + (filled_polygon + (pts + (xy 123.09 49.240848) (xy 123.087945 49.247622) (xy 123.081817 49.216814) (xy 122.879417 48.728175) (xy 122.585576 48.288412) + (xy 122.211588 47.914424) (xy 121.771825 47.620583) (xy 121.384142 47.46) (xy 122.215123 47.46) (xy 122.25 47.463435) + (xy 122.284877 47.46) (xy 122.389184 47.449727) (xy 122.52302 47.409128) (xy 122.646363 47.3432) (xy 122.754475 47.254475) + (xy 122.8432 47.146363) (xy 122.909128 47.02302) (xy 122.949727 46.889184) (xy 122.963435 46.75) (xy 122.96 46.715123) + (xy 122.96 46.513072) (xy 123.090001 46.513072) + ) + ) + (filled_polygon + (pts + (xy 110.210095 44.991827) (xy 110.210095 47.114649) (xy 110.076509 47.127806) (xy 110.068438 47.130254) (xy 109.986451 46.902722) + (xy 109.924471 46.786765) (xy 109.68438 46.719785) (xy 108.89842 47.505745) (xy 108.912563 47.519888) (xy 108.732958 47.699493) + (xy 108.718815 47.68535) (xy 108.704673 47.699493) (xy 108.525068 47.519888) (xy 108.53921 47.505745) (xy 108.525068 47.491603) + (xy 108.704673 47.311998) (xy 108.718815 47.32614) (xy 109.504775 46.54018) (xy 109.437795 46.300089) (xy 109.302055 46.23626) + (xy 109.380542 46.20375) (xy 109.60935 46.050865) (xy 109.803935 45.85628) (xy 109.95682 45.627472) (xy 110.062129 45.373235) + (xy 110.115815 45.103337) (xy 110.115815 44.897547) + ) + ) + (filled_polygon + (pts + (xy 166.68524 43.373311) (xy 166.84656 43.4054) (xy 166.865 43.4054) (xy 166.865 45.953254) (xy 166.75 45.941928) + (xy 164.956887 45.941928) (xy 165.084609 45.750779) (xy 165.204089 45.462327) (xy 165.265 45.156109) (xy 165.265 44.843891) + (xy 165.204089 44.537673) (xy 165.084609 44.249221) (xy 164.91115 43.989621) (xy 164.690379 43.76885) (xy 164.430779 43.595391) + (xy 164.142327 43.475911) (xy 163.836109 43.415) (xy 163.523891 43.415) (xy 163.217673 43.475911) (xy 163.123303 43.515) + (xy 162.95374 43.515) (xy 162.666842 43.572068) (xy 162.66 43.574902) (xy 162.66 43.4308) (xy 162.71844 43.4308) + (xy 162.87976 43.398711) (xy 162.983357 43.3558) (xy 166.642965 43.3558) + ) + ) + (filled_polygon + (pts + (xy 153.945628 40.970049) (xy 153.973341 41.003817) (xy 154.007109 41.03153) (xy 154.007111 41.031532) (xy 154.08378 41.094453) + (xy 154.108099 41.114411) (xy 154.261845 41.196589) (xy 154.428668 41.247195) (xy 154.558681 41.26) (xy 154.558689 41.26) + (xy 154.602158 41.264281) (xy 154.645627 41.26) (xy 154.894499 41.26) (xy 154.948815 41.326185) (xy 155.045506 41.405537) + (xy 155.15582 41.464502) (xy 155.275518 41.500812) (xy 155.4 41.513072) (xy 156.14 41.513072) (xy 156.14 41.695923) + (xy 156.136565 41.7308) (xy 156.150273 41.869984) (xy 156.190872 42.00382) (xy 156.2568 42.127163) (xy 156.345525 42.235275) + (xy 156.442702 42.315026) (xy 156.453637 42.324) (xy 156.57698 42.389928) (xy 156.710816 42.430527) (xy 156.85 42.444235) + (xy 156.884877 42.4408) (xy 157.762211 42.4408) (xy 157.328175 42.620583) (xy 156.888412 42.914424) (xy 156.514424 43.288412) + (xy 156.220583 43.728175) (xy 156.018183 44.216814) (xy 155.915 44.735551) (xy 155.915 45.264449) (xy 156.018183 45.783186) + (xy 156.023749 45.796623) (xy 155.801302 45.647989) (xy 155.492012 45.519877) (xy 155.527932 45.433158) (xy 155.585 45.14626) + (xy 155.585 44.85374) (xy 155.527932 44.566842) (xy 155.41599 44.296589) (xy 155.253475 44.053368) (xy 155.046632 43.846525) + (xy 154.803411 43.68401) (xy 154.533158 43.572068) (xy 154.24626 43.515) (xy 154.076697 43.515) (xy 153.982327 43.475911) + (xy 153.676109 43.415) (xy 153.363891 43.415) (xy 153.057673 43.475911) (xy 152.769221 43.595391) (xy 152.75998 43.601566) + (xy 152.75998 42.090953) (xy 152.810242 42.015731) (xy 152.873186 41.86377) (xy 152.905275 41.70245) (xy 152.905275 41.53797) + (xy 152.873186 41.37665) (xy 152.810242 41.224689) (xy 152.718862 41.087929) (xy 152.602556 40.971623) (xy 152.465796 40.880243) + (xy 152.313835 40.817299) (xy 152.152515 40.78521) (xy 151.988035 40.78521) (xy 151.826715 40.817299) (xy 151.674754 40.880243) + (xy 151.613072 40.921458) (xy 151.613072 40.615) (xy 151.609329 40.576992) (xy 151.666178 40.614977) (xy 151.818139 40.677921) + (xy 151.979459 40.71001) (xy 152.143939 40.71001) (xy 152.305259 40.677921) (xy 152.45722 40.614977) (xy 152.473316 40.604222) + (xy 152.479614 40.606831) (xy 152.640934 40.63892) (xy 152.805414 40.63892) (xy 152.966734 40.606831) (xy 153.118695 40.543887) + (xy 153.255455 40.452507) (xy 153.341771 40.366191) + ) + ) + (filled_polygon + (pts + (xy 131.359627 42.717428) (xy 130.525 42.717428) (xy 130.400518 42.729688) (xy 130.28082 42.765998) (xy 130.170506 42.824963) + (xy 130.073815 42.904315) (xy 129.994463 43.001006) (xy 129.960257 43.065) (xy 129.91776 43.065) (xy 129.804704 43.087489) + (xy 129.755537 42.995506) (xy 129.676185 42.898815) (xy 129.579494 42.819463) (xy 129.46918 42.760498) (xy 129.349482 42.724188) + (xy 129.225 42.711928) (xy 128.275 42.711928) (xy 128.150518 42.724188) (xy 128.03082 42.760498) (xy 127.920506 42.819463) + (xy 127.823815 42.898815) (xy 127.744463 42.995506) (xy 127.685498 43.10582) (xy 127.652379 43.215) (xy 127.412322 43.215) + (xy 127.374999 43.211324) (xy 127.337676 43.215) (xy 127.337667 43.215) (xy 127.226014 43.225997) (xy 127.082753 43.269454) + (xy 126.950724 43.340026) (xy 126.944903 43.344803) (xy 126.863996 43.411201) (xy 126.863992 43.411205) (xy 126.834999 43.434999) + (xy 126.811205 43.463992) (xy 126.458076 43.817122) (xy 126.354479 43.860033) (xy 126.217719 43.951413) (xy 126.211841 43.957291) + (xy 126.189967 43.904481) (xy 126.098587 43.767721) (xy 125.982281 43.651415) (xy 125.845521 43.560035) (xy 125.69356 43.497091) + (xy 125.53224 43.465002) (xy 125.36776 43.465002) (xy 125.20644 43.497091) (xy 125.054479 43.560035) (xy 124.917719 43.651415) + (xy 124.801413 43.767721) (xy 124.710033 43.904481) (xy 124.667122 44.008079) (xy 124.270533 44.404667) (xy 124.289502 44.36918) + (xy 124.325812 44.249482) (xy 124.338072 44.125) (xy 124.335 43.91075) (xy 124.17625 43.752) (xy 123.027 43.752) + (xy 123.027 43.772) (xy 122.96 43.772) (xy 122.96 43.478) (xy 123.027 43.478) (xy 123.027 43.498) + (xy 124.17625 43.498) (xy 124.335 43.33925) (xy 124.338072 43.125) (xy 124.325812 43.000518) (xy 124.289502 42.88082) + (xy 124.230537 42.770506) (xy 124.151185 42.673815) (xy 124.054494 42.594463) (xy 123.94418 42.535498) (xy 123.824482 42.499188) + (xy 123.7 42.486928) (xy 123.18575 42.49) (xy 123.027002 42.648748) (xy 123.027002 42.49) (xy 122.96 42.49) + (xy 122.96 42.41) (xy 131.052199 42.41) + ) + ) + (filled_polygon + (pts + (xy 161.14 44.115859) (xy 160.979417 43.728175) (xy 160.685576 43.288412) (xy 160.311588 42.914424) (xy 159.871825 42.620583) + (xy 159.437789 42.4408) (xy 160.315123 42.4408) (xy 160.35 42.444235) (xy 160.384877 42.4408) (xy 160.398006 42.439507) + (xy 160.489184 42.430527) (xy 160.62302 42.389928) (xy 160.746363 42.324) (xy 160.854475 42.235275) (xy 160.9432 42.127163) + (xy 161.009128 42.00382) (xy 161.049727 41.869984) (xy 161.058097 41.785) (xy 161.063435 41.7308) (xy 161.06 41.695923) + (xy 161.06 41.513072) (xy 161.140001 41.513072) + ) + ) + (filled_polygon + (pts + (xy 107.613748 43.755858) (xy 107.599605 43.77) (xy 107.613748 43.784143) (xy 107.434143 43.963748) (xy 107.42 43.949605) + (xy 107.405858 43.963748) (xy 107.226253 43.784143) (xy 107.240395 43.77) (xy 107.226253 43.755858) (xy 107.405858 43.576253) + (xy 107.42 43.590395) (xy 107.434143 43.576253) + ) + ) + (filled_polygon + (pts + (xy 167.409687 37.618411) (xy 167.255941 37.700589) (xy 167.121183 37.811183) (xy 167.010589 37.945942) (xy 166.928411 38.099688) + (xy 166.877805 38.266511) (xy 166.865 38.396524) (xy 166.865 41.7354) (xy 166.84656 41.7354) (xy 166.68524 41.767489) + (xy 166.533279 41.830433) (xy 166.525247 41.8358) (xy 162.983357 41.8358) (xy 162.87976 41.792889) (xy 162.71844 41.7608) + (xy 162.66 41.7608) (xy 162.66 40.969822) (xy 162.663676 40.932499) (xy 162.66 40.895176) (xy 162.66 40.895167) + (xy 162.649003 40.783514) (xy 162.605546 40.640253) (xy 162.600108 40.630079) (xy 162.560191 40.5554) (xy 162.563804 40.550997) + (xy 162.791911 40.32289) (xy 162.895537 40.279967) (xy 163.032297 40.188587) (xy 163.148603 40.072281) (xy 163.239983 39.935521) + (xy 163.302927 39.78356) (xy 163.335016 39.62224) (xy 163.335016 39.45776) (xy 163.302927 39.29644) (xy 163.239983 39.144479) + (xy 163.148603 39.007719) (xy 163.032297 38.891413) (xy 162.895537 38.800033) (xy 162.743576 38.737089) (xy 162.582256 38.705) + (xy 162.417776 38.705) (xy 162.256456 38.737089) (xy 162.220457 38.752) (xy 161.127 38.752) (xy 161.127 38.772) + (xy 161.06 38.772) (xy 161.06 38.478) (xy 161.127 38.478) (xy 161.127 38.498) (xy 162.27625 38.498) + (xy 162.435 38.33925) (xy 162.438072 38.125) (xy 162.425812 38.000518) (xy 162.389502 37.88082) (xy 162.330537 37.770506) + (xy 162.251185 37.673815) (xy 162.154494 37.594463) (xy 162.147622 37.59079) (xy 167.50074 37.59079) + ) + ) + (filled_polygon + (pts + (xy 142.027 40.998) (xy 142.047 40.998) (xy 142.047 41.252) (xy 142.027 41.252) (xy 142.027 41.272) + (xy 141.96 41.272) (xy 141.96 40.978) (xy 142.027 40.978) + ) + ) + (filled_polygon + (pts + (xy 182.019511 37.44) (xy 172.042602 37.44) (xy 170.472384 35.869783) (xy 170.448581 35.840779) (xy 170.332856 35.745806) + (xy 170.219098 35.685) (xy 170.896299 35.685) + ) + ) + (filled_polygon + (pts + (xy 153.944944 35.745806) (xy 153.944942 35.745807) (xy 153.944943 35.745807) (xy 153.858216 35.816981) (xy 153.858212 35.816985) + (xy 153.829219 35.840779) (xy 153.805425 35.869772) (xy 152.685199 36.99) (xy 152.266679 36.99) (xy 152.229356 36.986324) + (xy 152.192034 36.99) (xy 152.192023 36.99) (xy 152.08037 37.000997) (xy 152.068235 37.004678) (xy 115.204767 37.004678) + (xy 149.013379 35.685) (xy 154.058702 35.685) + ) + ) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.lib b/Sofle_RGB_v3/PCB/SofleKeyboard.lib new file mode 100644 index 00000000..a65f666b --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.lib @@ -0,0 +1,42 @@ +EESchema-LIBRARY Version 2.4 +#encoding utf-8 +# +# LED_sk2812_SM +# +DEF LED_sk2812_SM D 0 40 Y Y 1 F N +F0 "D" 0 150 50 H V C CNN +F1 "LED_sk2812_SM" 0 -150 50 H V C CNN +F2 "" 0 0 50 H I C CNN +F3 "" 0 0 50 H I C CNN +DRAW +T 0 0 0 31 0 1 1 SK6812mini Normal 0 C C +S 150 -100 -150 100 1 1 0 f +X DOUT 1 -200 50 50 R 25 25 1 1 O +X VSS 2 -200 -50 50 R 25 25 1 1 W +X DIN 3 200 -50 50 L 25 25 1 1 I +X VDD 4 200 50 50 L 25 25 1 1 W +ENDDRAW +ENDDEF +# +# SW_PUSH-MX_W_LED +# +DEF SW_PUSH-MX_W_LED SW? 0 40 Y Y 2 L N +F0 "SW?" 0 150 50 H V C CNN +F1 "SW_PUSH-MX_W_LED" 50 -150 25 H V C CNN +F2 "Button_Switch_Keyboard:SK6812MINI_and_cherry" 0 150 50 H I C CNN +F3 "" 0 150 50 H I C CNN +DRAW +T 0 0 0 31 0 2 0 SK6812mini Normal 0 C C +S -170 50 170 60 1 1 0 N +S 150 -100 -150 100 2 1 0 f +P 4 1 1 0 -40 60 -30 90 30 90 40 60 N +X ~ 5 300 0 200 L 25 24 1 1 P I +X ~ 6 -300 0 200 R 25 24 1 1 P I +X DOUT 1 -200 50 50 R 25 25 2 1 O +X VSS 2 -200 -50 50 R 25 25 2 1 W +X DIN 3 200 -50 50 L 25 25 2 1 I +X VDD 4 200 50 50 L 25 25 2 1 W +ENDDRAW +ENDDEF +# +#End Library diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.net b/Sofle_RGB_v3/PCB/SofleKeyboard.net new file mode 100644 index 00000000..6f3f231c --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.net @@ -0,0 +1,899 @@ +(export (version D) + (design + (source /Users/kata0510/git/Lily58/pcb/Lily58_Socket/Lily58_Socket.sch) + (date "2018 November 16, Friday 04:10:34") + (tool "Eeschema (5.0.0-3-g5ebb6b6)") + (sheet (number 1) (name /) (tstamps /) + (title_block + (title) + (company) + (rev) + (date) + (source Lily58_Socket.sch) + (comment (number 1) (value "")) + (comment (number 2) (value "")) + (comment (number 3) (value "")) + (comment (number 4) (value ""))))) + (components + (comp (ref U1) + (value ProMicro) + (footprint Lily58-footprint:ProMicro_rev2) + (libsource (lib "") (part ProMicro_2) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722440)) + (comp (ref SW25) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722503)) + (comp (ref SW26) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722582)) + (comp (ref SW1) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7225DA)) + (comp (ref D1) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7226E7)) + (comp (ref SW2) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7227CD)) + (comp (ref D2) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722847)) + (comp (ref SW3) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7228F7)) + (comp (ref D3) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722950)) + (comp (ref SW4) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722A11)) + (comp (ref D4) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722A8F)) + (comp (ref SW5) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722B51)) + (comp (ref D5) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722BAD)) + (comp (ref SW6) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722CA9)) + (comp (ref D6) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B722FE1)) + (comp (ref SW8) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723388)) + (comp (ref SW9) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723731)) + (comp (ref SW10) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7237A6)) + (comp (ref SW11) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B72387D)) + (comp (ref SW12) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723AD3)) + (comp (ref SW7) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723C9D)) + (comp (ref D7) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723D94)) + (comp (ref D8) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723E5F)) + (comp (ref D9) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B723FA1)) + (comp (ref D10) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7240EA)) + (comp (ref D11) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B72424D)) + (comp (ref D12) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7243C0)) + (comp (ref SW13) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7250AD)) + (comp (ref SW14) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B725133)) + (comp (ref SW15) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7251BF)) + (comp (ref SW16) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B72524E)) + (comp (ref SW17) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7252F1)) + (comp (ref SW18) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B725398)) + (comp (ref D13) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7254EE)) + (comp (ref D14) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7255FF)) + (comp (ref D15) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B72571C)) + (comp (ref D16) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B725841)) + (comp (ref D17) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B72596D)) + (comp (ref D18) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B725AA2)) + (comp (ref SW21) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B726F89)) + (comp (ref SW22) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727035)) + (comp (ref SW23) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7270F6)) + (comp (ref SW24) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7271A5)) + (comp (ref SW20) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727256)) + (comp (ref SW19) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727312)) + (comp (ref D19) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B72767A)) + (comp (ref D20) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7277CE)) + (comp (ref D21) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727929)) + (comp (ref D22) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727A89)) + (comp (ref D23) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727BFE)) + (comp (ref D24) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B727D79)) + (comp (ref SW27) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7293B0)) + (comp (ref SW28) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B734347)) + (comp (ref SW29) + (value SW_PUSH) + (footprint Lily58-footprint:CherryMX_KailhLowProfile_Hotswap) + (libsource (lib "") (part SW_PUSH) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B73449B)) + (comp (ref D25) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B734844)) + (comp (ref D26) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B7349D1)) + (comp (ref D27) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B734B62)) + (comp (ref D28) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B734CF9)) + (comp (ref D29) + (value D) + (footprint Lily58-footprint:Diode_SOD123) + (libsource (lib "") (part D) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B734F9E)) + (comp (ref R1) + (value R) + (footprint Lily58-footprint:RESISTOR_mini) + (libsource (lib "") (part R) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B739F4A)) + (comp (ref R2) + (value R) + (footprint Lily58-footprint:RESISTOR_mini) + (libsource (lib "") (part R) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B73A034)) + (comp (ref J2) + (value 4PIN) + (footprint Lily58-footprint:MJ-4PP-9) + (libsource (lib "") (part MJ-4PP-9) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B742D8C)) + (comp (ref J1) + (value LED) + (footprint Lily58-footprint:LED) + (libsource (lib "") (part LED) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74AE32)) + (comp (ref TH1) + (value HOLE) + (footprint Lily58-footprint:M2_HOLE_PCB) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74CE27)) + (comp (ref TH2) + (value HOLE) + (footprint Lily58-footprint:M2_HOLE_PCB) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74D0C7)) + (comp (ref TH4) + (value HOLE) + (footprint Lily58-footprint:HOLE_M2_TH) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74D1C0)) + (comp (ref TH5) + (value HOLE) + (footprint Lily58-footprint:HOLE_M2_TH) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74D78B)) + (comp (ref TH6) + (value HOLE) + (footprint Lily58-footprint:HOLE_M2_TH) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74D88C)) + (comp (ref TH7) + (value HOLE) + (footprint Lily58-footprint:HOLE_M2_TH) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74D98F)) + (comp (ref TH3) + (value HOLE) + (footprint Lily58-footprint:HOLE_M2_TH) + (libsource (lib "") (part HOLE) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B74DA95)) + (comp (ref RSW1) + (value SW_RST) + (footprint Lily58-footprint:TACT_SWITCH_TVBP06) + (libsource (lib "") (part SW_RST) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B8CE7E7)) + (comp (ref P1) + (value i2c_pin) + (footprint Lily58-footprint:1pin_conn) + (libsource (lib "") (part i2c_pin) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B8F6780)) + (comp (ref P2) + (value i2c_pin) + (footprint Lily58-footprint:1pin_conn) + (libsource (lib "") (part i2c_pin) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B8F6980)) + (comp (ref W1) + (value jumper) + (footprint Lily58-footprint:jumper_data) + (libsource (lib Device) (part Jumper) (description "Jumper, generic, normally closed")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B900157)) + (comp (ref J3) + (value OLED) + (footprint Lily58-footprint:OLED_4Pin) + (libsource (lib "") (part OLED) (description "")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B91007B)) + (comp (ref JP1) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B911E74)) + (comp (ref JP2) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B9120CE)) + (comp (ref JP3) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B913646)) + (comp (ref JP4) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B913C11)) + (comp (ref JP5) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B9141F4)) + (comp (ref JP6) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B9141FA)) + (comp (ref JP7) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B914200)) + (comp (ref JP8) + (value Jumper_NO_Small) + (footprint Lily58-footprint:Jumper) + (datasheet ~) + (libsource (lib Device) (part Jumper_NO_Small) (description "Jumper, normally open")) + (sheetpath (names /) (tstamps /)) + (tstamp 5B914206))) + (libparts + (libpart (lib "") (part Lily58-cache:D) + (footprints + (fp TO-???*) + (fp *_Diode_*) + (fp *SingleDiode*) + (fp D_*)) + (fields + (field (name Reference) D) + (field (name Value) Lily58-cache:D)) + (pins + (pin (num 1) (name K) (type passive)) + (pin (num 2) (name A) (type passive)))) + (libpart (lib "") (part Lily58-cache:HOLE) + (fields + (field (name Reference) U) + (field (name Value) Lily58-cache:HOLE))) + (libpart (lib "") (part Lily58-cache:LED) + (footprints + (fp Connector*:*_??x*mm*) + (fp Connector*:*1x??x*mm*) + (fp Pin?Header?Straight?1X*) + (fp Pin?Header?Angled?1X*) + (fp Socket?Strip?Straight?1X*) + (fp Socket?Strip?Angled?1X*)) + (fields + (field (name Reference) J) + (field (name Value) Lily58-cache:LED)) + (pins + (pin (num 1) (name Pin_1) (type passive)) + (pin (num 2) (name Pin_2) (type passive)) + (pin (num 3) (name Pin_3) (type passive)))) + (libpart (lib "") (part Lily58-cache:MJ-4PP-9) + (fields + (field (name Reference) J) + (field (name Value) Lily58-cache:MJ-4PP-9)) + (pins + (pin (num 1) (name ~) (type passive)) + (pin (num 2) (name ~) (type passive)) + (pin (num 3) (name ~) (type passive)) + (pin (num 4) (name ~) (type passive)))) + (libpart (lib "") (part Lily58-cache:OLED) + (footprints + (fp Pin_Header_Straight_1X04) + (fp Pin_Header_Angled_1X04) + (fp Socket_Strip_Straight_1X04) + (fp Socket_Strip_Angled_1X04)) + (fields + (field (name Reference) J) + (field (name Value) Lily58-cache:OLED)) + (pins + (pin (num 1) (name P1) (type passive)) + (pin (num 2) (name P2) (type passive)) + (pin (num 3) (name P3) (type passive)) + (pin (num 4) (name P4) (type passive)))) + (libpart (lib "") (part Lily58-cache:ProMicro_2) + (fields + (field (name Reference) U) + (field (name Value) Lily58-cache:ProMicro_2)) + (pins + (pin (num 1) (name "TX(PD3)") (type input)) + (pin (num 2) (name "RX(PD2)") (type input)) + (pin (num 3) (name GND) (type input)) + (pin (num 4) (name GND) (type input)) + (pin (num 5) (name "SDA(PD1)") (type input)) + (pin (num 6) (name "SCL(PD0)") (type input)) + (pin (num 7) (name "D4(PD4)") (type input)) + (pin (num 8) (name "D5(PC6)") (type input)) + (pin (num 9) (name "D6(PD7)") (type input)) + (pin (num 10) (name "D7(PE6)") (type input)) + (pin (num 11) (name "D8(PB4)") (type input)) + (pin (num 12) (name "D9(PB5)") (type input)) + (pin (num 13) (name "D10(PB6)") (type input)) + (pin (num 14) (name "D16(PB2)") (type input)) + (pin (num 15) (name "D14(PB3)") (type input)) + (pin (num 16) (name "D15(PB1)") (type input)) + (pin (num 17) (name "A0(PF7)") (type input)) + (pin (num 18) (name "A1(PF6)") (type input)) + (pin (num 19) (name "A2(PF5)") (type input)) + (pin (num 20) (name "A3(PF4)") (type input)) + (pin (num 21) (name VCC) (type input)) + (pin (num 22) (name RST) (type input)) + (pin (num 23) (name GND) (type input)) + (pin (num 24) (name RAW) (type input)))) + (libpart (lib "") (part Lily58-cache:R) + (footprints + (fp R_*)) + (fields + (field (name Reference) R) + (field (name Value) Lily58-cache:R)) + (pins + (pin (num 1) (name ~) (type passive)) + (pin (num 2) (name ~) (type passive)))) + (libpart (lib "") (part Lily58-cache:SW_PUSH) + (fields + (field (name Reference) SW) + (field (name Value) Lily58-cache:SW_PUSH)) + (pins + (pin (num 1) (name 1) (type passive)) + (pin (num 2) (name 2) (type passive)))) + (libpart (lib "") (part Lily58-cache:SW_RST) + (fields + (field (name Reference) RSW) + (field (name Value) Lily58-cache:SW_RST)) + (pins + (pin (num 1) (name 1) (type passive)) + (pin (num 2) (name 2) (type passive)))) + (libpart (lib "") (part Lily58-cache:i2c_pin) + (footprints + (fp Connector*:*_??x*mm*) + (fp Connector*:*1x??x*mm*) + (fp Pin?Header?Straight?1X*) + (fp Pin?Header?Angled?1X*) + (fp Socket?Strip?Straight?1X*) + (fp Socket?Strip?Angled?1X*)) + (fields + (field (name Reference) J) + (field (name Value) Lily58-cache:i2c_pin)) + (pins + (pin (num 1) (name Pin_1) (type passive)))) + (libpart (lib Device) (part Jumper) + (description "Jumper, generic, normally closed") + (docs ~) + (fields + (field (name Reference) JP) + (field (name Value) Jumper)) + (pins + (pin (num 1) (name 1) (type passive)) + (pin (num 2) (name 2) (type passive)))) + (libpart (lib Device) (part Jumper_NO_Small) + (description "Jumper, normally open") + (docs ~) + (fields + (field (name Reference) JP) + (field (name Value) Jumper_NO_Small)) + (pins + (pin (num 1) (name 1) (type passive)) + (pin (num 2) (name 2) (type passive))))) + (libraries + (library (logical Device) + (uri "/Library/Application Support/kicad/library/Device.lib"))) + (nets + (net (code 1) (name LED) + (node (ref U1) (pin 1)) + (node (ref J1) (pin 2))) + (net (code 2) (name "Net-(U1-Pad19)") + (node (ref U1) (pin 19))) + (net (code 3) (name DATA) + (node (ref W1) (pin 1)) + (node (ref U1) (pin 2))) + (net (code 4) (name "Net-(U1-Pad20)") + (node (ref U1) (pin 20))) + (net (code 5) (name RESET) + (node (ref RSW1) (pin 2)) + (node (ref U1) (pin 22))) + (net (code 6) (name "Net-(U1-Pad24)") + (node (ref U1) (pin 24))) + (net (code 7) (name SDA) + (node (ref JP5) (pin 2)) + (node (ref R1) (pin 2)) + (node (ref U1) (pin 5)) + (node (ref JP4) (pin 2))) + (net (code 8) (name SCL) + (node (ref R2) (pin 2)) + (node (ref JP3) (pin 2)) + (node (ref JP6) (pin 2)) + (node (ref U1) (pin 6))) + (net (code 9) (name "Net-(U1-Pad7)") + (node (ref U1) (pin 7))) + (net (code 10) (name "Net-(D25-Pad2)") + (node (ref SW25) (pin 2)) + (node (ref D25) (pin 2))) + (net (code 11) (name "Net-(D26-Pad2)") + (node (ref SW26) (pin 2)) + (node (ref D26) (pin 2))) + (net (code 12) (name "Net-(D1-Pad2)") + (node (ref SW1) (pin 2)) + (node (ref D1) (pin 2))) + (net (code 13) (name "Net-(D2-Pad2)") + (node (ref SW2) (pin 2)) + (node (ref D2) (pin 2))) + (net (code 14) (name "Net-(D3-Pad2)") + (node (ref SW3) (pin 2)) + (node (ref D3) (pin 2))) + (net (code 15) (name "Net-(D4-Pad2)") + (node (ref SW4) (pin 2)) + (node (ref D4) (pin 2))) + (net (code 16) (name "Net-(D5-Pad2)") + (node (ref D5) (pin 2)) + (node (ref SW5) (pin 2))) + (net (code 17) (name "Net-(D6-Pad2)") + (node (ref SW6) (pin 2)) + (node (ref D6) (pin 2))) + (net (code 18) (name "Net-(D8-Pad2)") + (node (ref SW8) (pin 2)) + (node (ref D8) (pin 2))) + (net (code 19) (name "Net-(D9-Pad2)") + (node (ref SW9) (pin 2)) + (node (ref D9) (pin 2))) + (net (code 20) (name "Net-(D10-Pad2)") + (node (ref D10) (pin 2)) + (node (ref SW10) (pin 2))) + (net (code 21) (name "Net-(D11-Pad2)") + (node (ref D11) (pin 2)) + (node (ref SW11) (pin 2))) + (net (code 22) (name "Net-(D12-Pad2)") + (node (ref D12) (pin 2)) + (node (ref SW12) (pin 2))) + (net (code 23) (name "Net-(D7-Pad2)") + (node (ref SW7) (pin 2)) + (node (ref D7) (pin 2))) + (net (code 24) (name "Net-(D13-Pad2)") + (node (ref D13) (pin 2)) + (node (ref SW13) (pin 2))) + (net (code 25) (name "Net-(D14-Pad2)") + (node (ref D14) (pin 2)) + (node (ref SW14) (pin 2))) + (net (code 26) (name "Net-(D15-Pad2)") + (node (ref D15) (pin 2)) + (node (ref SW15) (pin 2))) + (net (code 27) (name "Net-(D16-Pad2)") + (node (ref D16) (pin 2)) + (node (ref SW16) (pin 2))) + (net (code 28) (name "Net-(D17-Pad2)") + (node (ref D17) (pin 2)) + (node (ref SW17) (pin 2))) + (net (code 29) (name "Net-(D18-Pad2)") + (node (ref D18) (pin 2)) + (node (ref SW18) (pin 2))) + (net (code 30) (name "Net-(D21-Pad2)") + (node (ref SW21) (pin 2)) + (node (ref D21) (pin 2))) + (net (code 31) (name "Net-(D22-Pad2)") + (node (ref D22) (pin 2)) + (node (ref SW22) (pin 2))) + (net (code 32) (name "Net-(D23-Pad2)") + (node (ref SW23) (pin 2)) + (node (ref D23) (pin 2))) + (net (code 33) (name col0) + (node (ref SW18) (pin 1)) + (node (ref SW12) (pin 1)) + (node (ref U1) (pin 18)) + (node (ref SW6) (pin 1)) + (node (ref SW24) (pin 1))) + (net (code 34) (name "Net-(D24-Pad2)") + (node (ref D24) (pin 2)) + (node (ref SW24) (pin 2))) + (net (code 35) (name col4) + (node (ref SW14) (pin 1)) + (node (ref SW26) (pin 1)) + (node (ref U1) (pin 14)) + (node (ref SW8) (pin 1)) + (node (ref SW2) (pin 1)) + (node (ref SW20) (pin 1))) + (net (code 36) (name "Net-(D20-Pad2)") + (node (ref SW20) (pin 2)) + (node (ref D20) (pin 2))) + (net (code 37) (name col5) + (node (ref U1) (pin 13)) + (node (ref SW19) (pin 1)) + (node (ref SW13) (pin 1)) + (node (ref SW25) (pin 1)) + (node (ref SW7) (pin 1)) + (node (ref SW1) (pin 1))) + (net (code 38) (name "Net-(D19-Pad2)") + (node (ref SW19) (pin 2)) + (node (ref D19) (pin 2))) + (net (code 39) (name col3) + (node (ref U1) (pin 15)) + (node (ref SW3) (pin 1)) + (node (ref SW9) (pin 1)) + (node (ref SW27) (pin 1)) + (node (ref SW21) (pin 1)) + (node (ref SW15) (pin 1))) + (net (code 40) (name "Net-(D27-Pad2)") + (node (ref SW27) (pin 2)) + (node (ref D27) (pin 2))) + (net (code 41) (name col2) + (node (ref SW16) (pin 1)) + (node (ref U1) (pin 16)) + (node (ref SW22) (pin 1)) + (node (ref SW28) (pin 1)) + (node (ref SW10) (pin 1)) + (node (ref SW4) (pin 1))) + (net (code 42) (name "Net-(D28-Pad2)") + (node (ref D28) (pin 2)) + (node (ref SW28) (pin 2))) + (net (code 43) (name col1) + (node (ref SW5) (pin 1)) + (node (ref SW11) (pin 1)) + (node (ref SW29) (pin 1)) + (node (ref SW23) (pin 1)) + (node (ref U1) (pin 17)) + (node (ref SW17) (pin 1))) + (net (code 44) (name "Net-(D29-Pad2)") + (node (ref SW29) (pin 2)) + (node (ref D29) (pin 2))) + (net (code 45) (name row0) + (node (ref U1) (pin 8)) + (node (ref D1) (pin 1)) + (node (ref D2) (pin 1)) + (node (ref D3) (pin 1)) + (node (ref D4) (pin 1)) + (node (ref D5) (pin 1)) + (node (ref D6) (pin 1))) + (net (code 46) (name row1) + (node (ref U1) (pin 9)) + (node (ref D7) (pin 1)) + (node (ref D8) (pin 1)) + (node (ref D9) (pin 1)) + (node (ref D10) (pin 1)) + (node (ref D11) (pin 1)) + (node (ref D12) (pin 1))) + (net (code 47) (name row2) + (node (ref U1) (pin 10)) + (node (ref D13) (pin 1)) + (node (ref D14) (pin 1)) + (node (ref D15) (pin 1)) + (node (ref D16) (pin 1)) + (node (ref D17) (pin 1)) + (node (ref D18) (pin 1))) + (net (code 48) (name row3) + (node (ref D19) (pin 1)) + (node (ref D20) (pin 1)) + (node (ref D21) (pin 1)) + (node (ref D22) (pin 1)) + (node (ref D23) (pin 1)) + (node (ref D24) (pin 1)) + (node (ref U1) (pin 11))) + (net (code 49) (name row4) + (node (ref U1) (pin 12)) + (node (ref D25) (pin 1)) + (node (ref D26) (pin 1)) + (node (ref D27) (pin 1)) + (node (ref D28) (pin 1)) + (node (ref D29) (pin 1))) + (net (code 50) (name VCC) + (node (ref U1) (pin 21)) + (node (ref JP7) (pin 2)) + (node (ref J1) (pin 1)) + (node (ref J2) (pin 1)) + (node (ref JP2) (pin 2)) + (node (ref R2) (pin 1)) + (node (ref R1) (pin 1))) + (net (code 51) (name GND) + (node (ref J1) (pin 3)) + (node (ref U1) (pin 23)) + (node (ref U1) (pin 3)) + (node (ref U1) (pin 4)) + (node (ref JP1) (pin 2)) + (node (ref RSW1) (pin 1)) + (node (ref J2) (pin 2)) + (node (ref JP8) (pin 2))) + (net (code 52) (name "Net-(J2-Pad4)") + (node (ref J2) (pin 4)) + (node (ref P1) (pin 1))) + (net (code 53) (name "Net-(J2-Pad3)") + (node (ref P2) (pin 1)) + (node (ref W1) (pin 2)) + (node (ref J2) (pin 3))) + (net (code 54) (name "Net-(J3-Pad2)") + (node (ref JP7) (pin 1)) + (node (ref J3) (pin 2)) + (node (ref JP3) (pin 1))) + (net (code 55) (name "Net-(J3-Pad3)") + (node (ref JP6) (pin 1)) + (node (ref J3) (pin 3)) + (node (ref JP2) (pin 1))) + (net (code 56) (name "Net-(J3-Pad4)") + (node (ref JP5) (pin 1)) + (node (ref JP1) (pin 1)) + (node (ref J3) (pin 4))) + (net (code 57) (name "Net-(J3-Pad1)") + (node (ref JP4) (pin 1)) + (node (ref J3) (pin 1)) + (node (ref JP8) (pin 1))))) \ No newline at end of file diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.pro b/Sofle_RGB_v3/PCB/SofleKeyboard.pro new file mode 100644 index 00000000..188f191e --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.pro @@ -0,0 +1,43 @@ +update=Ne 22. září 2019, 16:36:42 CEST +version=1 +last_client=kicad +[general] +version=1 +RootSch= +BoardNm= +[pcbnew] +version=1 +LastNetListRead= +UseCmpFile=1 +PadDrill=0.600000000000 +PadDrillOvalY=0.600000000000 +PadSizeH=1.500000000000 +PadSizeV=1.500000000000 +PcbTextSizeV=1.500000000000 +PcbTextSizeH=1.500000000000 +PcbTextThickness=0.300000000000 +ModuleTextSizeV=1.000000000000 +ModuleTextSizeH=1.000000000000 +ModuleTextSizeThickness=0.150000000000 +SolderMaskClearance=0.000000000000 +SolderMaskMinWidth=0.000000000000 +DrawSegmentWidth=0.200000000000 +BoardOutlineThickness=0.100000000000 +ModuleOutlineThickness=0.150000000000 +[cvpcb] +version=1 +NetIExt=net +[eeschema] +version=1 +LibDir= +[eeschema/libraries] +[schematic_editor] +version=1 +PageLayoutDescrFile= +PlotDirectoryName= +SubpartIdSeparator=0 +SubpartFirstId=65 +NetFmtName=Pcbnew +SpiceAjustPassiveValues=0 +LabSize=50 +ERC_TestSimilarLabels=1 diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.sch b/Sofle_RGB_v3/PCB/SofleKeyboard.sch new file mode 100644 index 00000000..390e01f9 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.sch @@ -0,0 +1,2627 @@ +EESchema Schematic File Version 4 +EELAYER 30 0 +EELAYER END +$Descr A4 11693 8268 +encoding utf-8 +Sheet 1 1 +Title "" +Date "" +Rev "" +Comp "" +Comment1 "" +Comment2 "" +Comment3 "" +Comment4 "" +$EndDescr +Text GLabel 6050 3750 0 50 Input ~ 0 +row0 +Text GLabel 6050 4400 0 50 Input ~ 0 +row1 +Text GLabel 6050 5050 0 50 Input ~ 0 +row2 +Text GLabel 6050 5700 0 50 Input ~ 0 +row3 +Text GLabel 6050 6350 0 50 Input ~ 0 +row4 +Text GLabel 10300 3450 1 50 Input ~ 0 +col0 +Text GLabel 9500 3450 1 50 Input ~ 0 +col1 +Text GLabel 8700 3450 1 50 Input ~ 0 +col2 +Text GLabel 7900 3450 1 50 Input ~ 0 +col3 +Text GLabel 7100 3450 1 50 Input ~ 0 +col4 +Text GLabel 6300 3450 1 50 Input ~ 0 +col5 +Wire Wire Line + 6050 6350 6900 6350 +Text GLabel 2400 1950 2 50 Input ~ 0 +col5 +Text GLabel 2400 1850 2 50 Input ~ 0 +col4 +Text GLabel 2400 1750 2 50 Input ~ 0 +col3 +Text GLabel 2400 1650 2 50 Input ~ 0 +col2 +Text GLabel 2400 1550 2 50 Input ~ 0 +col1 +Text GLabel 2400 1450 2 50 Input ~ 0 +col0 +NoConn ~ 1100 1450 +Text GLabel 2400 1050 2 50 Input ~ 0 +RESET +NoConn ~ 2400 850 +Text GLabel 1100 850 0 50 Input ~ 0 +LED +Text GLabel 1100 1350 0 50 Input ~ 0 +SCL +Text GLabel 1100 1250 0 50 Input ~ 0 +SDA +Text GLabel 1100 1550 0 50 Input ~ 0 +row0 +Text GLabel 1100 1650 0 50 Input ~ 0 +row1 +Text GLabel 1100 1750 0 50 Input ~ 0 +row2 +Text GLabel 1100 1850 0 50 Input ~ 0 +row3 +Text GLabel 1100 1950 0 50 Input ~ 0 +row4 +Text GLabel 2850 3950 3 50 Input ~ 0 +SDA +Text GLabel 2750 2300 2 50 Input ~ 0 +LED +Text GLabel 1200 2450 2 50 Input ~ 0 +RESET +Text GLabel 3000 3950 3 50 Input ~ 0 +SCL +Connection ~ 8500 3750 +Wire Wire Line + 8500 3750 9300 3750 +Wire Wire Line + 7100 3450 7100 4100 +Wire Wire Line + 7700 3750 8500 3750 +Connection ~ 8700 5400 +Connection ~ 9300 5700 +Wire Wire Line + 9300 5700 10100 5700 +Connection ~ 7900 5400 +Connection ~ 8500 5700 +Wire Wire Line + 8500 5700 9300 5700 +Connection ~ 7100 5400 +Wire Wire Line + 7100 5400 7100 6050 +Wire Wire Line + 7700 5700 8500 5700 +Connection ~ 7100 4750 +Wire Wire Line + 7100 4750 7100 5400 +Wire Wire Line + 7700 5050 8500 5050 +Connection ~ 7900 4750 +Wire Wire Line + 7900 4750 7900 5400 +Connection ~ 8500 5050 +Wire Wire Line + 8500 5050 9300 5050 +Connection ~ 8700 4750 +Wire Wire Line + 8700 4750 8700 5400 +Connection ~ 9300 5050 +Wire Wire Line + 9300 5050 10100 5050 +Connection ~ 8700 4100 +Wire Wire Line + 8700 4100 8700 4750 +Connection ~ 9300 4400 +Wire Wire Line + 9300 4400 10100 4400 +Wire Wire Line + 8700 3450 8700 4100 +Connection ~ 7900 4100 +Wire Wire Line + 7900 4100 7900 4750 +Connection ~ 8500 4400 +Wire Wire Line + 8500 4400 9300 4400 +Wire Wire Line + 7900 3450 7900 4100 +Connection ~ 7100 4100 +Wire Wire Line + 7100 4100 7100 4750 +Wire Wire Line + 7700 4400 8500 4400 +Connection ~ 9500 4100 +Connection ~ 10100 4400 +Wire Wire Line + 10100 4400 10900 4400 +Wire Wire Line + 9500 3450 9500 4100 +Connection ~ 10100 5050 +Wire Wire Line + 10100 5050 10900 5050 +Wire Wire Line + 9500 4100 9500 4750 +Connection ~ 10100 5700 +Wire Wire Line + 10100 5700 10900 5700 +Wire Wire Line + 9500 5400 9500 6050 +Connection ~ 9300 6350 +Wire Wire Line + 9300 6350 10100 6350 +Wire Wire Line + 8700 5400 8700 6050 +Connection ~ 8500 6350 +Wire Wire Line + 8500 6350 9300 6350 +Wire Wire Line + 7900 5400 7900 6050 +Connection ~ 7700 6350 +Wire Wire Line + 7700 6350 8500 6350 +Connection ~ 6900 6350 +Wire Wire Line + 6900 6350 7700 6350 +Wire Wire Line + 9500 5400 9500 4750 +Connection ~ 9500 5400 +Connection ~ 9500 4750 +Wire Wire Line + 10300 4750 10300 5400 +Wire Wire Line + 10300 4750 10300 4100 +Connection ~ 10300 4750 +Wire Wire Line + 10300 4100 10300 3450 +Connection ~ 10300 4100 +Wire Wire Line + 6300 3450 6300 4100 +Wire Wire Line + 6300 4100 6300 4750 +Connection ~ 6300 4100 +Wire Wire Line + 6300 4750 6300 5400 +Connection ~ 6300 4750 +Wire Wire Line + 6300 5400 6300 6050 +Connection ~ 6300 5400 +Wire Wire Line + 10100 3750 10900 3750 +Wire Wire Line + 10100 3750 9300 3750 +Connection ~ 10100 3750 +Connection ~ 9300 3750 +Wire Wire Line + 7700 3750 6900 3750 +Connection ~ 7700 3750 +Wire Wire Line + 6900 3750 6050 3750 +Connection ~ 6900 3750 +Wire Wire Line + 7700 4400 6900 4400 +Connection ~ 7700 4400 +Wire Wire Line + 6900 4400 6050 4400 +Connection ~ 6900 4400 +Wire Wire Line + 7700 5050 6900 5050 +Connection ~ 7700 5050 +Wire Wire Line + 6900 5050 6050 5050 +Connection ~ 6900 5050 +Wire Wire Line + 7700 5700 6900 5700 +Connection ~ 7700 5700 +Wire Wire Line + 6900 5700 6050 5700 +Connection ~ 6900 5700 +Wire Wire Line + 1100 1050 1100 1150 +Wire Wire Line + 1100 1150 850 1150 +Connection ~ 1100 1150 +Wire Wire Line + 1700 3200 1600 3200 +Wire Wire Line + 1600 3300 1700 3300 +Wire Wire Line + 1600 3400 2000 3400 +Wire Wire Line + 1600 3050 2000 3050 +Wire Wire Line + 1700 3000 1700 3200 +Wire Wire Line + 1700 3300 1700 3450 +Text GLabel 1100 950 0 50 Input ~ 0 +DATA +Text GLabel 2600 3400 2 50 Input ~ 0 +DATA +Wire Wire Line + 1000 3800 1150 3800 +Wire Wire Line + 1000 3900 1100 3900 +Wire Wire Line + 1000 4000 1050 4000 +Wire Wire Line + 1200 4100 1000 4100 +Wire Wire Line + 1000 4100 1000 4550 +Wire Wire Line + 1000 4550 1200 4550 +Connection ~ 1000 4100 +Wire Wire Line + 1050 4000 1050 4450 +Wire Wire Line + 1050 4450 1200 4450 +Connection ~ 1050 4000 +Wire Wire Line + 1050 4000 1200 4000 +Wire Wire Line + 1100 3900 1100 4350 +Wire Wire Line + 1100 4350 1200 4350 +Connection ~ 1100 3900 +Wire Wire Line + 1100 3900 1200 3900 +Wire Wire Line + 1150 3800 1150 4250 +Wire Wire Line + 1150 4250 1200 4250 +Connection ~ 1150 3800 +Wire Wire Line + 1150 3800 1200 3800 +Text GLabel 1400 4350 2 50 Input ~ 0 +SCL +Text GLabel 1400 4250 2 50 Input ~ 0 +SDA +Text GLabel 1400 4000 2 50 Input ~ 0 +SCL +Text GLabel 1400 4100 2 50 Input ~ 0 +SDA +Wire Wire Line + 2400 950 2700 950 +Wire Wire Line + 2400 1150 2700 1150 +Connection ~ 2000 3400 +Wire Wire Line + 10300 5400 10300 6050 +Connection ~ 10300 5400 +Wire Wire Line + 10100 6350 10900 6350 +Connection ~ 10100 6350 +Text GLabel 3150 6050 2 50 Input ~ 0 +SW25A +Text GLabel 3150 6250 2 50 Input ~ 0 +SW25B +Wire Wire Line + 2850 6050 3150 6050 +Wire Wire Line + 2850 6250 3150 6250 +Text GLabel 6350 6050 2 50 Input ~ 0 +SW25A +Text GLabel 6900 5900 0 50 Input ~ 0 +SW25B +Wire Wire Line + 6900 5900 6900 6050 +Wire Wire Line + 6300 6050 6350 6050 +Text GLabel 2400 1250 2 50 Input ~ 0 +ENCA +Text GLabel 2400 1350 2 50 Input ~ 0 +ENCB +Text GLabel 2100 6050 0 50 Input ~ 0 +ENCA +Text GLabel 2100 6250 0 50 Input ~ 0 +ENCB +Wire Wire Line + 2100 6250 2250 6250 +Wire Wire Line + 2100 6050 2250 6050 +Wire Wire Line + 2250 6150 1650 6150 +Wire Wire Line + 1650 6150 1650 6250 +Text Label 1800 3400 0 50 ~ 0 +i2c_d +Text Label 1750 3050 0 50 ~ 0 +i2c_c +Wire Wire Line + 5100 850 4850 850 +Wire Wire Line + 4850 850 4850 950 +Wire Wire Line + 4850 950 4700 950 +Wire Wire Line + 4300 850 4100 850 +Wire Wire Line + 4100 850 4100 950 +Wire Wire Line + 4100 950 3950 950 +Wire Wire Line + 3550 850 3350 850 +Wire Wire Line + 3350 1500 3550 1500 +Wire Wire Line + 3950 1600 4150 1600 +Wire Wire Line + 4150 1600 4150 1500 +Wire Wire Line + 4150 1500 4300 1500 +Wire Wire Line + 4700 1600 4900 1600 +Wire Wire Line + 4900 1600 4900 1500 +Wire Wire Line + 4900 1500 5100 1500 +Wire Wire Line + 5700 600 5500 600 +Wire Wire Line + 3950 600 3950 850 +Wire Wire Line + 4700 850 4700 600 +Connection ~ 4700 600 +Wire Wire Line + 4700 600 3950 600 +Wire Wire Line + 5500 850 5500 600 +Connection ~ 5500 600 +Wire Wire Line + 5500 600 4700 600 +Wire Wire Line + 3550 2000 4300 2000 +Connection ~ 4300 2000 +Wire Wire Line + 3550 2000 3250 2000 +Wire Wire Line + 3250 2000 3250 1850 +Connection ~ 3550 2000 +Wire Wire Line + 3350 850 3350 1500 +Wire Wire Line + 3950 1500 3950 1200 +Wire Wire Line + 3950 1200 3550 1200 +Wire Wire Line + 3550 1200 3550 950 +Wire Wire Line + 3950 1200 4300 1200 +Wire Wire Line + 4300 1200 4300 950 +Connection ~ 3950 1200 +Wire Wire Line + 4300 1200 4700 1200 +Wire Wire Line + 4700 1200 4700 1500 +Connection ~ 4300 1200 +Wire Wire Line + 4700 1200 5100 1200 +Wire Wire Line + 5100 1200 5100 950 +Connection ~ 4700 1200 +Connection ~ 5100 1200 +Wire Wire Line + 6350 700 6350 950 +Wire Wire Line + 5500 950 6350 950 +Text Label 5900 950 0 50 ~ 0 +underglow +Wire Wire Line + 5500 1500 5500 1200 +Wire Wire Line + 5100 1200 5500 1200 +Wire Wire Line + 6550 700 7100 700 +Wire Wire Line + 4300 2000 5100 2000 +Wire Wire Line + 3550 1600 3550 2000 +Wire Wire Line + 4300 1600 4300 2000 +Wire Wire Line + 5100 1600 5100 2000 +Text GLabel 4200 2500 1 50 Input ~ 0 +LED +Wire Wire Line + 4200 2500 4200 2550 +Wire Wire Line + 4450 2650 4300 2650 +Wire Wire Line + 4850 2650 5000 2650 +Wire Wire Line + 4450 2550 4200 2550 +Text GLabel 5000 2650 2 50 Input ~ 0 +lights +Text GLabel 6300 950 3 50 Input ~ 0 +lights +Text GLabel 3950 2550 0 50 Input ~ 0 +lights +Wire Wire Line + 5500 1200 5900 1200 +Connection ~ 5500 1200 +Wire Wire Line + 7100 1600 7100 700 +Wire Wire Line + 7550 1900 7550 2150 +Wire Wire Line + 7950 1900 7550 1900 +Wire Wire Line + 7950 1800 7950 1900 +Wire Wire Line + 7550 1450 7550 1700 +Wire Wire Line + 7950 1450 7550 1450 +Wire Wire Line + 7950 1350 7950 1450 +Wire Wire Line + 7550 1000 7550 1250 +Wire Wire Line + 7950 1000 7550 1000 +Wire Wire Line + 7950 900 7950 1000 +Wire Wire Line + 7500 800 7550 800 +Wire Wire Line + 7500 600 7500 800 +Wire Wire Line + 8150 600 7500 600 +Wire Wire Line + 8150 800 8150 600 +Wire Wire Line + 8550 1000 8550 900 +Wire Wire Line + 8150 1000 8550 1000 +Wire Wire Line + 8150 1250 8150 1000 +Wire Wire Line + 8550 1450 8550 1350 +Wire Wire Line + 8150 1450 8550 1450 +Wire Wire Line + 8150 1700 8150 1450 +Wire Wire Line + 8550 1900 8550 1800 +Wire Wire Line + 8150 1900 8550 1900 +Wire Wire Line + 8150 2150 8150 1900 +Wire Wire Line + 8550 2350 8550 2250 +Wire Wire Line + 8150 2350 8550 2350 +Wire Wire Line + 8150 2600 8150 2350 +Wire Wire Line + 8550 2800 8550 2700 +Wire Wire Line + 9150 2800 8550 2800 +Wire Wire Line + 9150 2700 9150 2800 +Wire Wire Line + 8750 2350 8750 2600 +Wire Wire Line + 9150 2350 8750 2350 +Wire Wire Line + 9150 2250 9150 2350 +Wire Wire Line + 8750 1900 8750 2150 +Wire Wire Line + 9150 1900 8750 1900 +Wire Wire Line + 9150 1800 9150 1900 +Wire Wire Line + 8750 1450 8750 1700 +Wire Wire Line + 9150 1450 8750 1450 +Wire Wire Line + 9150 1350 9150 1450 +Wire Wire Line + 8750 1000 8750 1250 +Wire Wire Line + 9150 1000 8750 1000 +Wire Wire Line + 9150 900 9150 1000 +Wire Wire Line + 8700 800 8750 800 +Wire Wire Line + 8700 600 8700 800 +Wire Wire Line + 9350 600 8700 600 +Wire Wire Line + 9350 800 9350 600 +Wire Wire Line + 9750 1000 9750 900 +Wire Wire Line + 9350 1000 9750 1000 +Wire Wire Line + 9350 1250 9350 1000 +Wire Wire Line + 9750 1450 9750 1350 +Wire Wire Line + 9350 1450 9750 1450 +Wire Wire Line + 9350 1700 9350 1450 +Wire Wire Line + 9750 1900 9750 1800 +Wire Wire Line + 9350 1900 9750 1900 +Wire Wire Line + 9350 2150 9350 1900 +Wire Wire Line + 9750 2350 9750 2250 +Wire Wire Line + 9350 2350 9750 2350 +Wire Wire Line + 9350 2600 9350 2350 +Wire Wire Line + 9250 2700 9250 2900 +Connection ~ 9250 2700 +Wire Wire Line + 9350 2700 9250 2700 +Wire Wire Line + 9250 2600 9250 2700 +Connection ~ 9250 2600 +Wire Wire Line + 9150 2600 9250 2600 +Wire Wire Line + 9250 2250 9250 2600 +Connection ~ 9250 2250 +Wire Wire Line + 9350 2250 9250 2250 +Wire Wire Line + 9250 2150 9250 2250 +Connection ~ 9250 2150 +Wire Wire Line + 9150 2150 9250 2150 +Wire Wire Line + 9250 1800 9250 2150 +Connection ~ 9250 1800 +Wire Wire Line + 9350 1800 9250 1800 +Wire Wire Line + 9250 1700 9250 1800 +Connection ~ 9250 1700 +Wire Wire Line + 9150 1700 9250 1700 +Wire Wire Line + 9250 1350 9250 1700 +Connection ~ 9250 1350 +Wire Wire Line + 9350 1350 9250 1350 +Wire Wire Line + 9250 1250 9250 1350 +Connection ~ 9250 1250 +Wire Wire Line + 9150 1250 9250 1250 +Wire Wire Line + 9250 900 9250 1250 +Connection ~ 9250 900 +Wire Wire Line + 9350 900 9250 900 +Wire Wire Line + 9250 800 9250 900 +Wire Wire Line + 9150 800 9250 800 +Wire Wire Line + 8650 800 8650 900 +Connection ~ 8650 800 +Wire Wire Line + 8550 800 8650 800 +Wire Wire Line + 8650 900 8650 1250 +Connection ~ 8650 900 +Wire Wire Line + 8750 900 8650 900 +Wire Wire Line + 8650 1250 8650 1350 +Connection ~ 8650 1250 +Wire Wire Line + 8550 1250 8650 1250 +Wire Wire Line + 8650 1350 8650 1700 +Connection ~ 8650 1350 +Wire Wire Line + 8750 1350 8650 1350 +Wire Wire Line + 8650 1700 8650 1800 +Connection ~ 8650 1700 +Wire Wire Line + 8550 1700 8650 1700 +Wire Wire Line + 8650 1800 8650 2150 +Connection ~ 8650 1800 +Wire Wire Line + 8750 1800 8650 1800 +Wire Wire Line + 8650 2250 8650 2600 +Connection ~ 8650 2250 +Wire Wire Line + 8750 2250 8650 2250 +Wire Wire Line + 8650 2150 8650 2250 +Connection ~ 8650 2150 +Wire Wire Line + 8550 2150 8650 2150 +Wire Wire Line + 8650 2600 8650 2700 +Connection ~ 8650 2600 +Wire Wire Line + 8550 2600 8650 2600 +Wire Wire Line + 8650 2700 8750 2700 +Wire Wire Line + 8650 550 8650 800 +Wire Wire Line + 7450 900 7450 1350 +Connection ~ 7450 900 +Wire Wire Line + 7550 900 7450 900 +Wire Wire Line + 7450 1350 7450 1800 +Connection ~ 7450 1350 +Wire Wire Line + 7550 1350 7450 1350 +Wire Wire Line + 7450 1800 7450 2250 +Connection ~ 7450 1800 +Wire Wire Line + 7550 1800 7450 1800 +Wire Wire Line + 7450 2250 7550 2250 +Wire Wire Line + 7450 550 7450 900 +Wire Wire Line + 8050 900 8050 1250 +Connection ~ 8050 900 +Wire Wire Line + 8050 800 8050 900 +Wire Wire Line + 7950 800 8050 800 +Connection ~ 8050 1250 +Wire Wire Line + 7950 1250 8050 1250 +Wire Wire Line + 8050 1350 8050 1250 +Connection ~ 8050 1350 +Wire Wire Line + 8150 1350 8050 1350 +Wire Wire Line + 8050 1700 8050 1350 +Connection ~ 8050 1700 +Wire Wire Line + 7950 1700 8050 1700 +Wire Wire Line + 8050 1800 8050 1700 +Connection ~ 8050 1800 +Wire Wire Line + 8150 1800 8050 1800 +Wire Wire Line + 8050 2150 8050 1800 +Connection ~ 8050 2150 +Wire Wire Line + 7950 2150 8050 2150 +Wire Wire Line + 8050 2250 8050 2150 +Connection ~ 8050 2250 +Wire Wire Line + 8150 2250 8050 2250 +Wire Wire Line + 8050 2700 8050 2250 +Connection ~ 8050 2700 +Wire Wire Line + 8150 2700 8050 2700 +Wire Wire Line + 8050 900 8150 900 +Wire Wire Line + 8050 2900 8050 2700 +Wire Wire Line + 10450 2600 10450 2700 +Connection ~ 10450 2600 +Wire Wire Line + 10350 2600 10450 2600 +Wire Wire Line + 10450 2150 10450 2250 +Connection ~ 10450 2150 +Wire Wire Line + 10450 1800 10450 2150 +Wire Wire Line + 10350 2150 10450 2150 +Wire Wire Line + 10450 1700 10450 1800 +Connection ~ 10450 1700 +Wire Wire Line + 10350 1700 10450 1700 +Wire Wire Line + 10450 1250 10450 1350 +Connection ~ 10450 1250 +Wire Wire Line + 10350 1250 10450 1250 +Wire Wire Line + 10450 900 10450 1250 +Connection ~ 10450 900 +Wire Wire Line + 10450 800 10450 900 +Wire Wire Line + 10350 800 10450 800 +Wire Wire Line + 9850 900 9850 800 +Connection ~ 9850 900 +Wire Wire Line + 9950 900 9850 900 +Wire Wire Line + 9850 800 9850 550 +Connection ~ 9850 800 +Wire Wire Line + 9750 800 9850 800 +Wire Wire Line + 9850 1350 9850 1250 +Connection ~ 9850 1350 +Wire Wire Line + 9950 1350 9850 1350 +Wire Wire Line + 9850 1250 9850 900 +Connection ~ 9850 1250 +Wire Wire Line + 9750 1250 9850 1250 +Wire Wire Line + 9850 1800 9850 1700 +Connection ~ 9850 1800 +Wire Wire Line + 9950 1800 9850 1800 +Wire Wire Line + 9850 1700 9850 1350 +Connection ~ 9850 1700 +Wire Wire Line + 9750 1700 9850 1700 +Wire Wire Line + 9850 2150 9850 1800 +Connection ~ 9850 2150 +Wire Wire Line + 9750 2150 9850 2150 +Wire Wire Line + 9850 2250 9850 2150 +Connection ~ 9850 2250 +Wire Wire Line + 9950 2250 9850 2250 +Wire Wire Line + 9850 2600 9850 2250 +Connection ~ 9850 2600 +Wire Wire Line + 9750 2600 9850 2600 +Wire Wire Line + 9850 2700 9850 2600 +Wire Wire Line + 9950 2700 9850 2700 +Wire Wire Line + 9750 2800 9750 2700 +Wire Wire Line + 10350 2800 9750 2800 +Wire Wire Line + 10350 2700 10350 2800 +Wire Wire Line + 9900 2600 9950 2600 +Wire Wire Line + 9900 2350 9900 2600 +Wire Wire Line + 10350 2350 9900 2350 +Wire Wire Line + 10350 2250 10350 2350 +Wire Wire Line + 9900 2150 9950 2150 +Wire Wire Line + 9900 1900 9900 2150 +Wire Wire Line + 10350 1900 9900 1900 +Wire Wire Line + 10350 1800 10350 1900 +Wire Wire Line + 9900 1700 9950 1700 +Wire Wire Line + 9900 1450 9900 1700 +Wire Wire Line + 10350 1450 9900 1450 +Wire Wire Line + 10350 1350 10350 1450 +Wire Wire Line + 9900 1250 9950 1250 +Wire Wire Line + 9900 1000 9900 1250 +Wire Wire Line + 10350 1000 9900 1000 +Wire Wire Line + 10350 900 10350 1000 +Wire Wire Line + 9900 800 9950 800 +Wire Wire Line + 9900 600 9900 800 +Wire Wire Line + 10550 600 9900 600 +Wire Wire Line + 10550 800 10550 600 +Wire Wire Line + 10950 1000 10950 900 +Wire Wire Line + 10550 1000 10950 1000 +Wire Wire Line + 10550 1250 10550 1000 +Wire Wire Line + 10950 1450 10950 1350 +Wire Wire Line + 10550 1450 10950 1450 +Wire Wire Line + 10550 1700 10550 1450 +Wire Wire Line + 10950 1900 10950 1800 +Wire Wire Line + 10550 1900 10950 1900 +Wire Wire Line + 10550 2150 10550 1900 +Wire Wire Line + 10950 2350 10950 2250 +Wire Wire Line + 10550 2350 10950 2350 +Wire Wire Line + 10550 2600 10550 2350 +Wire Wire Line + 10950 2700 10950 3000 +Wire Wire Line + 10450 2700 10450 2900 +Connection ~ 10450 2700 +Wire Wire Line + 10550 2700 10450 2700 +Wire Wire Line + 10450 2250 10450 2600 +Connection ~ 10450 2250 +Wire Wire Line + 10550 2250 10450 2250 +Connection ~ 10450 1800 +Wire Wire Line + 10550 1800 10450 1800 +Connection ~ 10450 1350 +Wire Wire Line + 10450 1350 10450 1700 +Wire Wire Line + 10450 1350 10550 1350 +Wire Wire Line + 10550 900 10450 900 +Connection ~ 11050 2150 +Wire Wire Line + 11050 2600 10950 2600 +Wire Wire Line + 11050 2150 11050 2600 +Connection ~ 11050 1700 +Wire Wire Line + 11050 2150 10950 2150 +Wire Wire Line + 11050 1700 11050 2150 +Connection ~ 11050 1250 +Wire Wire Line + 11050 1700 10950 1700 +Wire Wire Line + 11050 1250 11050 1700 +Connection ~ 11050 800 +Wire Wire Line + 11050 1250 10950 1250 +Wire Wire Line + 11050 800 11050 1250 +Wire Wire Line + 11050 800 11050 700 +Wire Wire Line + 10950 800 11050 800 +$Comp +L SofleKeyboard:LED_sk2812_SM D36 +U 1 1 5F7EF5F8 +P 5300 1550 +F 0 "D36" H 5300 1377 50 0000 C CNN +F 1 "LED_sk2812_SM" H 5300 1724 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 5300 1550 50 0001 C CNN +F 3 "" H 5300 1550 50 0001 C CNN + 1 5300 1550 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D37 +U 1 1 5F918D28 +P 4650 2600 +F 0 "D37" H 4650 2427 50 0000 C CNN +F 1 "LED_sk2812_SM" H 4650 2774 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 4650 2600 50 0001 C CNN +F 3 "" H 4650 2600 50 0001 C CNN + 1 4650 2600 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW1 +U 1 1 5B7225DA +P 6600 3450 +F 0 "SW1" H 6600 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 3450 50 0001 C CNN +F 3 "" H 6600 3450 50 0000 C CNN + 1 6600 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW2 +U 2 1 5F74DC46 +P 8350 850 +F 0 "SW2" H 8350 1023 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 1100 50 0001 C CNN +F 3 "" H 8350 1100 50 0001 C CNN + 2 8350 850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW2 +U 1 1 5B7227CD +P 7400 3450 +F 0 "SW2" H 7400 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 3450 50 0001 C CNN +F 3 "" H 7400 3450 50 0000 C CNN + 1 7400 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW3 +U 2 1 5F74EA54 +P 8950 850 +F 0 "SW3" H 8950 677 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 1100 50 0001 C CNN +F 3 "" H 8950 1100 50 0001 C CNN + 2 8950 850 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW4 +U 2 1 5F74FBCC +P 9550 850 +F 0 "SW4" H 9550 1023 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 1100 50 0001 C CNN +F 3 "" H 9550 1100 50 0001 C CNN + 2 9550 850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR024 +U 1 1 5FEF0394 +P 8050 2900 +F 0 "#PWR024" H 8050 2650 50 0001 C CNN +F 1 "GND" H 8055 2727 50 0000 C CNN +F 2 "" H 8050 2900 50 0001 C CNN +F 3 "" H 8050 2900 50 0001 C CNN + 1 8050 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR025 +U 1 1 5FEEFF47 +P 9250 2900 +F 0 "#PWR025" H 9250 2650 50 0001 C CNN +F 1 "GND" H 9255 2727 50 0000 C CNN +F 2 "" H 9250 2900 50 0001 C CNN +F 3 "" H 9250 2900 50 0001 C CNN + 1 9250 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR026 +U 1 1 5FEEF6D8 +P 10450 2900 +F 0 "#PWR026" H 10450 2650 50 0001 C CNN +F 1 "GND" H 10455 2727 50 0000 C CNN +F 2 "" H 10450 2900 50 0001 C CNN +F 3 "" H 10450 2900 50 0001 C CNN + 1 10450 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR015 +U 1 1 5FEEF38A +P 7450 550 +F 0 "#PWR015" H 7450 400 50 0001 C CNN +F 1 "VCC" H 7467 723 50 0000 C CNN +F 2 "" H 7450 550 50 0001 C CNN +F 3 "" H 7450 550 50 0001 C CNN + 1 7450 550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR016 +U 1 1 5FEEEC68 +P 8650 550 +F 0 "#PWR016" H 8650 400 50 0001 C CNN +F 1 "VCC" H 8667 723 50 0000 C CNN +F 2 "" H 8650 550 50 0001 C CNN +F 3 "" H 8650 550 50 0001 C CNN + 1 8650 550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR017 +U 1 1 5FEEE81F +P 9850 550 +F 0 "#PWR017" H 9850 400 50 0001 C CNN +F 1 "VCC" H 9867 723 50 0000 C CNN +F 2 "" H 9850 550 50 0001 C CNN +F 3 "" H 9850 550 50 0001 C CNN + 1 9850 550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR019 +U 1 1 5FBCA77E +P 11050 700 +F 0 "#PWR019" H 11050 550 50 0001 C CNN +F 1 "VCC" H 11067 873 50 0000 C CNN +F 2 "" H 11050 700 50 0001 C CNN +F 3 "" H 11050 700 50 0001 C CNN + 1 11050 700 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR023 +U 1 1 5FB348BA +P 5400 2850 +F 0 "#PWR023" H 5400 2600 50 0001 C CNN +F 1 "GND" H 5405 2677 50 0000 C CNN +F 2 "" H 5400 2850 50 0001 C CNN +F 3 "" H 5400 2850 50 0001 C CNN + 1 5400 2850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR022 +U 1 1 5FB33FDA +P 4100 2900 +F 0 "#PWR022" H 4100 2750 50 0001 C CNN +F 1 "VCC" H 4117 3073 50 0000 C CNN +F 2 "" H 4100 2900 50 0001 C CNN +F 3 "" H 4100 2900 50 0001 C CNN + 1 4100 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR021 +U 1 1 5F89E5EE +P 3250 1850 +F 0 "#PWR021" H 3250 1700 50 0001 C CNN +F 1 "VCC" H 3267 2023 50 0000 C CNN +F 2 "" H 3250 1850 50 0001 C CNN +F 3 "" H 3250 1850 50 0001 C CNN + 1 3250 1850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR020 +U 1 1 5F84539D +P 5900 1200 +F 0 "#PWR020" H 5900 950 50 0001 C CNN +F 1 "GND" H 5905 1027 50 0000 C CNN +F 2 "" H 5900 1200 50 0001 C CNN +F 3 "" H 5900 1200 50 0001 C CNN + 1 5900 1200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR018 +U 1 1 5F843EAE +P 5700 600 +F 0 "#PWR018" H 5700 450 50 0001 C CNN +F 1 "VCC" H 5717 773 50 0000 C CNN +F 2 "" H 5700 600 50 0001 C CNN +F 3 "" H 5700 600 50 0001 C CNN + 1 5700 600 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW30 +U 2 1 5F7D72C1 +P 10750 2650 +F 0 "SW30" H 10750 2823 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 2900 50 0001 C CNN +F 3 "" H 10750 2900 50 0001 C CNN + 2 10750 2650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW26 +U 2 1 5F7D72BB +P 8350 2650 +F 0 "SW26" H 8350 2823 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 2900 50 0001 C CNN +F 3 "" H 8350 2900 50 0001 C CNN + 2 8350 2650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW27 +U 2 1 5F7D72B5 +P 8950 2650 +F 0 "SW27" H 8950 2477 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 2900 50 0001 C CNN +F 3 "" H 8950 2900 50 0001 C CNN + 2 8950 2650 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW28 +U 2 1 5F7D72AF +P 9550 2650 +F 0 "SW28" H 9550 2823 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 2900 50 0001 C CNN +F 3 "" H 9550 2900 50 0001 C CNN + 2 9550 2650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW29 +U 2 1 5F7D72A9 +P 10150 2650 +F 0 "SW29" H 10150 2477 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 2900 50 0001 C CNN +F 3 "" H 10150 2900 50 0001 C CNN + 2 10150 2650 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW13 +U 2 1 5F7D01B3 +P 7750 1750 +F 0 "SW13" H 7750 1577 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 2000 50 0001 C CNN +F 3 "" H 7750 2000 50 0001 C CNN + 2 7750 1750 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW14 +U 2 1 5F7D01AD +P 8350 1750 +F 0 "SW14" H 8350 1923 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 2000 50 0001 C CNN +F 3 "" H 8350 2000 50 0001 C CNN + 2 8350 1750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW15 +U 2 1 5F7D01A7 +P 8950 1750 +F 0 "SW15" H 8950 1577 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 2000 50 0001 C CNN +F 3 "" H 8950 2000 50 0001 C CNN + 2 8950 1750 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW16 +U 2 1 5F7D01A1 +P 9550 1750 +F 0 "SW16" H 9550 1923 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 2000 50 0001 C CNN +F 3 "" H 9550 2000 50 0001 C CNN + 2 9550 1750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW17 +U 2 1 5F7D019B +P 10150 1750 +F 0 "SW17" H 10150 1577 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 2000 50 0001 C CNN +F 3 "" H 10150 2000 50 0001 C CNN + 2 10150 1750 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW18 +U 2 1 5F7D0195 +P 10750 1750 +F 0 "SW18" H 10750 1923 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 2000 50 0001 C CNN +F 3 "" H 10750 2000 50 0001 C CNN + 2 10750 1750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW19 +U 2 1 5F7D018F +P 7750 2200 +F 0 "SW19" H 7750 2027 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 2450 50 0001 C CNN +F 3 "" H 7750 2450 50 0001 C CNN + 2 7750 2200 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW20 +U 2 1 5F7D0189 +P 8350 2200 +F 0 "SW20" H 8350 2373 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 2450 50 0001 C CNN +F 3 "" H 8350 2450 50 0001 C CNN + 2 8350 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW21 +U 2 1 5F7D0183 +P 8950 2200 +F 0 "SW21" H 8950 2027 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 2450 50 0001 C CNN +F 3 "" H 8950 2450 50 0001 C CNN + 2 8950 2200 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW22 +U 2 1 5F7D017D +P 9550 2200 +F 0 "SW22" H 9550 2373 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 2450 50 0001 C CNN +F 3 "" H 9550 2450 50 0001 C CNN + 2 9550 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW23 +U 2 1 5F7D0177 +P 10150 2200 +F 0 "SW23" H 10150 2027 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 2450 50 0001 C CNN +F 3 "" H 10150 2450 50 0001 C CNN + 2 10150 2200 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW24 +U 2 1 5F7D0171 +P 10750 2200 +F 0 "SW24" H 10750 2373 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 2450 50 0001 C CNN +F 3 "" H 10750 2450 50 0001 C CNN + 2 10750 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:ProMicro_2-Lily58-cache-Lily58_Pro-rescue U1 +U 1 1 5B722440 +P 1750 1400 +F 0 "U1" H 1750 2100 60 0000 C CNN +F 1 "ProMicro" H 1750 700 60 0000 C CNN +F 2 "SofleRGB:ProMicro" H 1850 350 60 0001 C CNN +F 3 "" H 1850 350 60 0000 C CNN + 1 1750 1400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW26 +U 1 1 5B722582 +P 7400 6050 +F 0 "SW26" H 7400 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 6050 50 0001 C CNN +F 3 "" H 7400 6050 50 0000 C CNN + 1 7400 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D1 +U 1 1 5B7226E7 +P 6900 3600 +F 0 "D1" V 6946 3521 50 0000 R CNN +F 1 "D" V 6855 3521 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 6900 3600 50 0001 C CNN +F 3 "" H 6900 3600 50 0001 C CNN + 1 6900 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D2 +U 1 1 5B722847 +P 7700 3600 +F 0 "D2" V 7746 3521 50 0000 R CNN +F 1 "D" V 7655 3521 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 7700 3600 50 0001 C CNN +F 3 "" H 7700 3600 50 0001 C CNN + 1 7700 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW3 +U 1 1 5B7228F7 +P 8200 3450 +F 0 "SW3" H 8200 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 3450 50 0001 C CNN +F 3 "" H 8200 3450 50 0000 C CNN + 1 8200 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D3 +U 1 1 5B722950 +P 8500 3600 +F 0 "D3" V 8546 3521 50 0000 R CNN +F 1 "D" V 8455 3521 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 8500 3600 50 0001 C CNN +F 3 "" H 8500 3600 50 0001 C CNN + 1 8500 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D4 +U 1 1 5B722A8F +P 9300 3600 +F 0 "D4" V 9346 3521 50 0000 R CNN +F 1 "D" V 9255 3521 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 9300 3600 50 0001 C CNN +F 3 "" H 9300 3600 50 0001 C CNN + 1 9300 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW5 +U 1 1 5B722B51 +P 9800 3450 +F 0 "SW5" H 9800 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 3450 50 0001 C CNN +F 3 "" H 9800 3450 50 0000 C CNN + 1 9800 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D5 +U 1 1 5B722BAD +P 10100 3600 +F 0 "D5" V 10146 3521 50 0000 R CNN +F 1 "D" V 10055 3521 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10100 3600 50 0001 C CNN +F 3 "" H 10100 3600 50 0001 C CNN + 1 10100 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW6 +U 1 1 5B722CA9 +P 10600 3450 +F 0 "SW6" H 10600 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 3400 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 3450 50 0001 C CNN +F 3 "" H 10600 3450 50 0000 C CNN + 1 10600 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D6 +U 1 1 5B722FE1 +P 10900 3600 +F 0 "D6" V 10946 3521 50 0000 R CNN +F 1 "D" V 10855 3521 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10900 3600 50 0001 C CNN +F 3 "" H 10900 3600 50 0001 C CNN + 1 10900 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW8 +U 1 1 5B723388 +P 7400 4100 +F 0 "SW8" H 7400 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 4100 50 0001 C CNN +F 3 "" H 7400 4100 50 0000 C CNN + 1 7400 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW9 +U 1 1 5B723731 +P 8200 4100 +F 0 "SW9" H 8200 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 4100 50 0001 C CNN +F 3 "" H 8200 4100 50 0000 C CNN + 1 8200 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW10 +U 1 1 5B7237A6 +P 9000 4100 +F 0 "SW10" H 9000 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 4100 50 0001 C CNN +F 3 "" H 9000 4100 50 0000 C CNN + 1 9000 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW11 +U 1 1 5B72387D +P 9800 4100 +F 0 "SW11" H 9800 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 4100 50 0001 C CNN +F 3 "" H 9800 4100 50 0000 C CNN + 1 9800 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW12 +U 1 1 5B723AD3 +P 10600 4100 +F 0 "SW12" H 10600 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 4100 50 0001 C CNN +F 3 "" H 10600 4100 50 0000 C CNN + 1 10600 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW7 +U 1 1 5B723C9D +P 6600 4100 +F 0 "SW7" H 6600 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 4100 50 0001 C CNN +F 3 "" H 6600 4100 50 0000 C CNN + 1 6600 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D7 +U 1 1 5B723D94 +P 6900 4250 +F 0 "D7" V 6946 4171 50 0000 R CNN +F 1 "D" V 6855 4171 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 6900 4250 50 0001 C CNN +F 3 "" H 6900 4250 50 0001 C CNN + 1 6900 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D8 +U 1 1 5B723E5F +P 7700 4250 +F 0 "D8" V 7746 4171 50 0000 R CNN +F 1 "D" V 7655 4171 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 7700 4250 50 0001 C CNN +F 3 "" H 7700 4250 50 0001 C CNN + 1 7700 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D9 +U 1 1 5B723FA1 +P 8500 4250 +F 0 "D9" V 8546 4171 50 0000 R CNN +F 1 "D" V 8455 4171 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 8500 4250 50 0001 C CNN +F 3 "" H 8500 4250 50 0001 C CNN + 1 8500 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D10 +U 1 1 5B7240EA +P 9300 4250 +F 0 "D10" V 9346 4171 50 0000 R CNN +F 1 "D" V 9255 4171 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 9300 4250 50 0001 C CNN +F 3 "" H 9300 4250 50 0001 C CNN + 1 9300 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D11 +U 1 1 5B72424D +P 10100 4250 +F 0 "D11" V 10146 4171 50 0000 R CNN +F 1 "D" V 10055 4171 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10100 4250 50 0001 C CNN +F 3 "" H 10100 4250 50 0001 C CNN + 1 10100 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D12 +U 1 1 5B7243C0 +P 10900 4250 +F 0 "D12" V 10946 4171 50 0000 R CNN +F 1 "D" V 10855 4171 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10900 4250 50 0001 C CNN +F 3 "" H 10900 4250 50 0001 C CNN + 1 10900 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW13 +U 1 1 5B7250AD +P 6600 4750 +F 0 "SW13" H 6600 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 4750 50 0001 C CNN +F 3 "" H 6600 4750 50 0000 C CNN + 1 6600 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW14 +U 1 1 5B725133 +P 7400 4750 +F 0 "SW14" H 7400 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 4750 50 0001 C CNN +F 3 "" H 7400 4750 50 0000 C CNN + 1 7400 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW15 +U 1 1 5B7251BF +P 8200 4750 +F 0 "SW15" H 8200 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 4750 50 0001 C CNN +F 3 "" H 8200 4750 50 0000 C CNN + 1 8200 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW16 +U 1 1 5B72524E +P 9000 4750 +F 0 "SW16" H 9000 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 4750 50 0001 C CNN +F 3 "" H 9000 4750 50 0000 C CNN + 1 9000 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW17 +U 1 1 5B7252F1 +P 9800 4750 +F 0 "SW17" H 9800 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 4750 50 0001 C CNN +F 3 "" H 9800 4750 50 0000 C CNN + 1 9800 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW18 +U 1 1 5B725398 +P 10600 4750 +F 0 "SW18" H 10600 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 4750 50 0001 C CNN +F 3 "" H 10600 4750 50 0000 C CNN + 1 10600 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D13 +U 1 1 5B7254EE +P 6900 4900 +F 0 "D13" V 6946 4821 50 0000 R CNN +F 1 "D" V 6855 4821 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 6900 4900 50 0001 C CNN +F 3 "" H 6900 4900 50 0001 C CNN + 1 6900 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D14 +U 1 1 5B7255FF +P 7700 4900 +F 0 "D14" V 7746 4821 50 0000 R CNN +F 1 "D" V 7655 4821 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 7700 4900 50 0001 C CNN +F 3 "" H 7700 4900 50 0001 C CNN + 1 7700 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D15 +U 1 1 5B72571C +P 8500 4900 +F 0 "D15" V 8546 4821 50 0000 R CNN +F 1 "D" V 8455 4821 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 8500 4900 50 0001 C CNN +F 3 "" H 8500 4900 50 0001 C CNN + 1 8500 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D16 +U 1 1 5B725841 +P 9300 4900 +F 0 "D16" V 9346 4821 50 0000 R CNN +F 1 "D" V 9255 4821 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 9300 4900 50 0001 C CNN +F 3 "" H 9300 4900 50 0001 C CNN + 1 9300 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D17 +U 1 1 5B72596D +P 10100 4900 +F 0 "D17" V 10146 4821 50 0000 R CNN +F 1 "D" V 10055 4821 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10100 4900 50 0001 C CNN +F 3 "" H 10100 4900 50 0001 C CNN + 1 10100 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D18 +U 1 1 5B725AA2 +P 10900 4900 +F 0 "D18" V 10946 4821 50 0000 R CNN +F 1 "D" V 10855 4821 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10900 4900 50 0001 C CNN +F 3 "" H 10900 4900 50 0001 C CNN + 1 10900 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW21 +U 1 1 5B726F89 +P 8200 5400 +F 0 "SW21" H 8200 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 5400 50 0001 C CNN +F 3 "" H 8200 5400 50 0000 C CNN + 1 8200 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW22 +U 1 1 5B727035 +P 9000 5400 +F 0 "SW22" H 9000 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 5400 50 0001 C CNN +F 3 "" H 9000 5400 50 0000 C CNN + 1 9000 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW23 +U 1 1 5B7270F6 +P 9800 5400 +F 0 "SW23" H 9800 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 5400 50 0001 C CNN +F 3 "" H 9800 5400 50 0000 C CNN + 1 9800 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW24 +U 1 1 5B7271A5 +P 10600 5400 +F 0 "SW24" H 10600 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 5400 50 0001 C CNN +F 3 "" H 10600 5400 50 0000 C CNN + 1 10600 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW20 +U 1 1 5B727256 +P 7400 5400 +F 0 "SW20" H 7400 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 5400 50 0001 C CNN +F 3 "" H 7400 5400 50 0000 C CNN + 1 7400 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW19 +U 1 1 5B727312 +P 6600 5400 +F 0 "SW19" H 6600 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 5400 50 0001 C CNN +F 3 "" H 6600 5400 50 0000 C CNN + 1 6600 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D19 +U 1 1 5B72767A +P 6900 5550 +F 0 "D19" V 6946 5471 50 0000 R CNN +F 1 "D" V 6855 5471 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 6900 5550 50 0001 C CNN +F 3 "" H 6900 5550 50 0001 C CNN + 1 6900 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D20 +U 1 1 5B7277CE +P 7700 5550 +F 0 "D20" V 7746 5471 50 0000 R CNN +F 1 "D" V 7655 5471 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 7700 5550 50 0001 C CNN +F 3 "" H 7700 5550 50 0001 C CNN + 1 7700 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D21 +U 1 1 5B727929 +P 8500 5550 +F 0 "D21" V 8546 5471 50 0000 R CNN +F 1 "D" V 8455 5471 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 8500 5550 50 0001 C CNN +F 3 "" H 8500 5550 50 0001 C CNN + 1 8500 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D22 +U 1 1 5B727A89 +P 9300 5550 +F 0 "D22" V 9346 5471 50 0000 R CNN +F 1 "D" V 9255 5471 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 9300 5550 50 0001 C CNN +F 3 "" H 9300 5550 50 0001 C CNN + 1 9300 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D23 +U 1 1 5B727BFE +P 10100 5550 +F 0 "D23" V 10146 5471 50 0000 R CNN +F 1 "D" V 10055 5471 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10100 5550 50 0001 C CNN +F 3 "" H 10100 5550 50 0001 C CNN + 1 10100 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D24 +U 1 1 5B727D79 +P 10900 5550 +F 0 "D24" V 10946 5471 50 0000 R CNN +F 1 "D" V 10855 5471 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10900 5550 50 0001 C CNN +F 3 "" H 10900 5550 50 0001 C CNN + 1 10900 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW27 +U 1 1 5B7293B0 +P 8200 6050 +F 0 "SW27" H 8200 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 6050 50 0001 C CNN +F 3 "" H 8200 6050 50 0000 C CNN + 1 8200 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW28 +U 1 1 5B734347 +P 9000 6050 +F 0 "SW28" H 9000 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 6050 50 0001 C CNN +F 3 "" H 9000 6050 50 0000 C CNN + 1 9000 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW29 +U 1 1 5B73449B +P 9800 6050 +F 0 "SW29" H 9800 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 6050 50 0001 C CNN +F 3 "" H 9800 6050 50 0000 C CNN + 1 9800 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D25 +U 1 1 5B734844 +P 6900 6200 +F 0 "D25" V 6946 6121 50 0000 R CNN +F 1 "D" V 6855 6121 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 6900 6200 50 0001 C CNN +F 3 "" H 6900 6200 50 0001 C CNN + 1 6900 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D26 +U 1 1 5B7349D1 +P 7700 6200 +F 0 "D26" V 7746 6121 50 0000 R CNN +F 1 "D" V 7655 6121 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 7700 6200 50 0001 C CNN +F 3 "" H 7700 6200 50 0001 C CNN + 1 7700 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D27 +U 1 1 5B734B62 +P 8500 6200 +F 0 "D27" V 8546 6121 50 0000 R CNN +F 1 "D" V 8455 6121 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 8500 6200 50 0001 C CNN +F 3 "" H 8500 6200 50 0001 C CNN + 1 8500 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D28 +U 1 1 5B734CF9 +P 9300 6200 +F 0 "D28" V 9346 6121 50 0000 R CNN +F 1 "D" V 9255 6121 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 9300 6200 50 0001 C CNN +F 3 "" H 9300 6200 50 0001 C CNN + 1 9300 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D29 +U 1 1 5B734F9E +P 10100 6200 +F 0 "D29" V 10146 6121 50 0000 R CNN +F 1 "D" V 10055 6121 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10100 6200 50 0001 C CNN +F 3 "" H 10100 6200 50 0001 C CNN + 1 10100 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR04 +U 1 1 5B736B57 +P 2700 1150 +F 0 "#PWR04" H 2700 1000 50 0001 C CNN +F 1 "VCC" H 2700 1300 50 0000 C CNN +F 2 "" H 2700 1150 50 0001 C CNN +F 3 "" H 2700 1150 50 0001 C CNN + 1 2700 1150 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR05 +U 1 1 5B739B47 +P 2850 3650 +F 0 "#PWR05" H 2850 3500 50 0001 C CNN +F 1 "VCC" H 2850 3800 50 0000 C CNN +F 2 "" H 2850 3650 50 0001 C CNN +F 3 "" H 2850 3650 50 0001 C CNN + 1 2850 3650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR06 +U 1 1 5B739CDC +P 3000 3650 +F 0 "#PWR06" H 3000 3500 50 0001 C CNN +F 1 "VCC" H 3000 3800 50 0000 C CNN +F 2 "" H 3000 3650 50 0001 C CNN +F 3 "" H 3000 3650 50 0001 C CNN + 1 3000 3650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:R-Lily58-cache-Lily58_Pro-rescue R1 +U 1 1 5B739F4A +P 2850 3800 +F 0 "R1" V 2950 3800 50 0000 C BNN +F 1 "R" V 2850 3800 50 0000 C CNN +F 2 "SofleRGB:RESISTOR_mini" V 2780 3800 50 0001 C CNN +F 3 "" H 2850 3800 50 0001 C CNN + 1 2850 3800 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:R-Lily58-cache-Lily58_Pro-rescue R2 +U 1 1 5B73A034 +P 3000 3800 +F 0 "R2" V 3100 3800 50 0000 C BNN +F 1 "R" V 3000 3800 50 0000 C CNN +F 2 "SofleRGB:RESISTOR_mini" V 2930 3800 50 0001 C CNN +F 3 "" H 3000 3800 50 0001 C CNN + 1 3000 3800 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue J2 +U 1 1 5B742D8C +P 1150 3200 +F 0 "J2" H 1100 3500 60 0000 C CNN +F 1 "4PIN" H 1100 2900 60 0000 C CNN +F 2 "SofleRGB:MJ-4PP-9" H 1150 3150 60 0001 C CNN +F 3 "" H 1150 3150 60 0000 C CNN + 1 1150 3200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:LED-Lily58-cache-Lily58_Pro-rescue J1 +U 1 1 5B74AE32 +P 2550 2300 +F 0 "J1" H 2550 2500 50 0000 C CNN +F 1 "LED" H 2550 2100 50 0000 C CNN +F 2 "SofleRGB:LED" H 2550 2300 50 0001 C CNN +F 3 "" H 2550 2300 50 0001 C CNN + 1 2550 2300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR07 +U 1 1 5B74B06A +P 2750 2200 +F 0 "#PWR07" H 2750 2050 50 0001 C CNN +F 1 "VCC" H 2767 2373 50 0000 C CNN +F 2 "" H 2750 2200 50 0001 C CNN +F 3 "" H 2750 2200 50 0001 C CNN + 1 2750 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR08 +U 1 1 5B74B15A +P 2750 2400 +F 0 "#PWR08" H 2750 2150 50 0001 C CNN +F 1 "GND" H 2755 2227 50 0000 C CNN +F 2 "" H 2750 2400 50 0001 C CNN +F 3 "" H 2750 2400 50 0001 C CNN + 1 2750 2400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR010 +U 1 1 5B74C10F +P 900 2450 +F 0 "#PWR010" H 900 2200 50 0001 C CNN +F 1 "GND" H 905 2277 50 0000 C CNN +F 2 "" H 900 2450 50 0001 C CNN +F 3 "" H 900 2450 50 0001 C CNN + 1 900 2450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:PWR_FLAG-Lily58-cache-Lily58_Pro-rescue #FLG01 +U 1 1 5B74C681 +P 3550 7500 +F 0 "#FLG01" H 3550 7575 50 0001 C CNN +F 1 "PWR_FLAG" H 3550 7674 50 0000 C CNN +F 2 "" H 3550 7500 50 0001 C CNN +F 3 "" H 3550 7500 50 0001 C CNN + 1 3550 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR012 +U 1 1 5B74C7EB +P 3550 7500 +F 0 "#PWR012" H 3550 7250 50 0001 C CNN +F 1 "GND" H 3555 7327 50 0000 C CNN +F 2 "" H 3550 7500 50 0001 C CNN +F 3 "" H 3550 7500 50 0001 C CNN + 1 3550 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR013 +U 1 1 5B74C8DE +P 3900 7500 +F 0 "#PWR013" H 3900 7350 50 0001 C CNN +F 1 "VCC" H 3917 7673 50 0000 C CNN +F 2 "" H 3900 7500 50 0001 C CNN +F 3 "" H 3900 7500 50 0001 C CNN + 1 3900 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:PWR_FLAG-Lily58-cache-Lily58_Pro-rescue #FLG02 +U 1 1 5B74C9D1 +P 3900 7500 +F 0 "#FLG02" H 3900 7575 50 0001 C CNN +F 1 "PWR_FLAG" H 3900 7673 50 0000 C CNN +F 2 "" H 3900 7500 50 0001 C CNN +F 3 "" H 3900 7500 50 0001 C CNN + 1 3900 7500 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH1 +U 1 1 5B74CE27 +P 750 7500 +F 0 "TH1" H 750 7500 60 0000 C CNN +F 1 "HOLE" H 750 7400 60 0000 C CNN +F 2 "SofleRGB:M2_HOLE_PCB" H 750 7500 60 0001 C CNN +F 3 "" H 750 7500 60 0000 C CNN + 1 750 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH2 +U 1 1 5B74D0C7 +P 1100 7500 +F 0 "TH2" H 1100 7500 60 0000 C CNN +F 1 "HOLE" H 1100 7400 60 0000 C CNN +F 2 "SofleRGB:M2_HOLE_PCB" H 1100 7500 60 0001 C CNN +F 3 "" H 1100 7500 60 0000 C CNN + 1 1100 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH4 +U 1 1 5B74D1C0 +P 2100 7500 +F 0 "TH4" H 2100 7500 60 0000 C CNN +F 1 "HOLE" H 2100 7400 60 0000 C CNN +F 2 "SofleRGB:HOLE_M2_TH" H 2100 7500 60 0001 C CNN +F 3 "" H 2100 7500 60 0000 C CNN + 1 2100 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH5 +U 1 1 5B74D78B +P 2450 7500 +F 0 "TH5" H 2450 7500 60 0000 C CNN +F 1 "HOLE" H 2450 7400 60 0000 C CNN +F 2 "SofleRGB:HOLE_M2_TH" H 2450 7500 60 0001 C CNN +F 3 "" H 2450 7500 60 0000 C CNN + 1 2450 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH6 +U 1 1 5B74D88C +P 2800 7500 +F 0 "TH6" H 2800 7500 60 0000 C CNN +F 1 "HOLE" H 2800 7400 60 0000 C CNN +F 2 "SofleRGB:HOLE_M2_TH" H 2800 7500 60 0001 C CNN +F 3 "" H 2800 7500 60 0000 C CNN + 1 2800 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH7 +U 1 1 5B74D98F +P 3150 7500 +F 0 "TH7" H 3150 7500 60 0000 C CNN +F 1 "HOLE" H 3150 7400 60 0000 C CNN +F 2 "SofleRGB:HOLE_M2_TH" H 3150 7500 60 0001 C CNN +F 3 "" H 3150 7500 60 0000 C CNN + 1 3150 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH3 +U 1 1 5B74DA95 +P 1750 7500 +F 0 "TH3" H 1750 7500 60 0000 C CNN +F 1 "HOLE" H 1750 7400 60 0000 C CNN +F 2 "SofleRGB:HOLE_M2_TH" H 1750 7500 60 0001 C CNN +F 3 "" H 1750 7500 60 0000 C CNN + 1 1750 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:SW_RST-Lily58-cache-Lily58_Pro-rescue RSW1 +U 1 1 5B8CE7E7 +P 1050 2450 +F 0 "RSW1" H 1050 2706 40 0000 C CNN +F 1 "SW_RST" H 1050 2623 50 0000 C CNN +F 2 "SofleRGB:TACT_SWITCH_TVBP06" H 1050 2450 50 0001 C CNN +F 3 "" H 1050 2450 50 0001 C CNN + 1 1050 2450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR0101 +U 1 1 5B8CD05E +P 2700 950 +F 0 "#PWR0101" H 2700 700 50 0001 C CNN +F 1 "GND" H 2700 800 50 0000 C CNN +F 2 "" H 2700 950 50 0001 C CNN +F 3 "" H 2700 950 50 0001 C CNN + 1 2700 950 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR0102 +U 1 1 5B8CD27F +P 850 1150 +F 0 "#PWR0102" H 850 900 50 0001 C CNN +F 1 "GND" H 850 1000 50 0000 C CNN +F 2 "" H 850 1150 50 0001 C CNN +F 3 "" H 850 1150 50 0001 C CNN + 1 850 1150 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR02 +U 1 1 5B8F3218 +P 1700 3450 +F 0 "#PWR02" H 1700 3200 50 0001 C CNN +F 1 "GND" H 1705 3277 50 0000 C CNN +F 2 "" H 1700 3450 50 0001 C CNN +F 3 "" H 1700 3450 50 0001 C CNN + 1 1700 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-power #PWR01 +U 1 1 5B8F42DA +P 1700 3000 +F 0 "#PWR01" H 1700 2850 50 0001 C CNN +F 1 "VCC" H 1717 3173 50 0000 C CNN +F 2 "" H 1700 3000 50 0001 C CNN +F 3 "" H 1700 3000 50 0001 C CNN + 1 1700 3000 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:i2c_pin-Lily58-cache-Lily58_Pro-rescue P1 +U 1 1 5B8F6780 +P 2000 2850 +F 0 "P1" H 2000 2950 50 0000 C CNN +F 1 "i2c_pin" V 2100 2850 50 0000 C CNN +F 2 "SofleRGB:1pin_conn" H 2000 2850 50 0001 C CNN +F 3 "" H 2000 2850 50 0001 C CNN + 1 2000 2850 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:i2c_pin-Lily58-cache-Lily58_Pro-rescue P2 +U 1 1 5B8F6980 +P 2000 3600 +F 0 "P2" H 2000 3500 50 0000 C CNN +F 1 "i2c_pin" V 2100 3600 50 0000 C CNN +F 2 "SofleRGB:1pin_conn" H 2000 3600 50 0001 C CNN +F 3 "" H 2000 3600 50 0001 C CNN + 1 2000 3600 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper-Device W1 +U 1 1 5B900157 +P 2300 3400 +F 0 "W1" H 2300 3350 50 0000 C CNN +F 1 "jumper" H 2300 3550 50 0000 C CNN +F 2 "SofleRGB:jumper_data" H 2300 3400 50 0001 C CNN +F 3 "" H 2300 3400 50 0000 C CNN + 1 2300 3400 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard-rescue:OLED-Lily58-cache-Lily58_Pro-rescue J3 +U 1 1 5B91007B +P 800 3950 +F 0 "J3" H 800 3700 50 0000 C CNN +F 1 "OLED" H 800 4200 50 0000 C CNN +F 2 "SofleRGB:OLED_4Pin" H 800 3950 50 0001 C CNN +F 3 "" H 800 3950 50 0000 C CNN + 1 800 3950 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP1 +U 1 1 5B911E74 +P 1300 3800 +F 0 "JP1" H 1300 3750 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 3894 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 3800 50 0001 C CNN +F 3 "~" H 1300 3800 50 0001 C CNN + 1 1300 3800 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP2 +U 1 1 5B9120CE +P 1300 3900 +F 0 "JP2" H 1300 3850 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 3994 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 3900 50 0001 C CNN +F 3 "~" H 1300 3900 50 0001 C CNN + 1 1300 3900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP3 +U 1 1 5B913646 +P 1300 4000 +F 0 "JP3" H 1300 3950 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4094 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 4000 50 0001 C CNN +F 3 "~" H 1300 4000 50 0001 C CNN + 1 1300 4000 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP4 +U 1 1 5B913C11 +P 1300 4100 +F 0 "JP4" H 1300 4050 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4194 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 4100 50 0001 C CNN +F 3 "~" H 1300 4100 50 0001 C CNN + 1 1300 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP5 +U 1 1 5B9141F4 +P 1300 4250 +F 0 "JP5" H 1300 4200 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4344 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 4250 50 0001 C CNN +F 3 "~" H 1300 4250 50 0001 C CNN + 1 1300 4250 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP6 +U 1 1 5B9141FA +P 1300 4350 +F 0 "JP6" H 1300 4300 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4444 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 4350 50 0001 C CNN +F 3 "~" H 1300 4350 50 0001 C CNN + 1 1300 4350 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP7 +U 1 1 5B914200 +P 1300 4450 +F 0 "JP7" H 1300 4400 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4544 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 4450 50 0001 C CNN +F 3 "~" H 1300 4450 50 0001 C CNN + 1 1300 4450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP8 +U 1 1 5B914206 +P 1300 4550 +F 0 "JP8" H 1300 4500 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4644 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 1300 4550 50 0001 C CNN +F 3 "~" H 1300 4550 50 0001 C CNN + 1 1300 4550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR03 +U 1 1 5B9205B8 +P 1400 3800 +F 0 "#PWR03" H 1400 3550 50 0001 C CNN +F 1 "GND" V 1405 3672 50 0000 R CNN +F 2 "" H 1400 3800 50 0001 C CNN +F 3 "" H 1400 3800 50 0001 C CNN + 1 1400 3800 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-power #PWR09 +U 1 1 5B9207DA +P 1400 3900 +F 0 "#PWR09" H 1400 3750 50 0001 C CNN +F 1 "VCC" V 1417 4028 50 0000 L CNN +F 2 "" H 1400 3900 50 0001 C CNN +F 3 "" H 1400 3900 50 0001 C CNN + 1 1400 3900 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR014 +U 1 1 5B920A11 +P 1400 4550 +F 0 "#PWR014" H 1400 4300 50 0001 C CNN +F 1 "GND" V 1405 4422 50 0000 R CNN +F 2 "" H 1400 4550 50 0001 C CNN +F 3 "" H 1400 4550 50 0001 C CNN + 1 1400 4550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-power #PWR011 +U 1 1 5B920C33 +P 1400 4450 +F 0 "#PWR011" H 1400 4300 50 0001 C CNN +F 1 "VCC" V 1417 4578 50 0000 L CNN +F 2 "" H 1400 4450 50 0001 C CNN +F 3 "" H 1400 4450 50 0001 C CNN + 1 1400 4450 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW30 +U 1 1 5D954F78 +P 10600 6050 +F 0 "SW30" H 10600 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 6050 50 0001 C CNN +F 3 "" H 10600 6050 50 0000 C CNN + 1 10600 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D30 +U 1 1 5D956FE1 +P 10900 6200 +F 0 "D30" V 10946 6121 50 0000 R CNN +F 1 "D" V 10855 6121 50 0000 R CNN +F 2 "SofleRGB:crkbd-diode" H 10900 6200 50 0001 C CNN +F 3 "" H 10900 6200 50 0001 C CNN + 1 10900 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:Rotary_Encoder_Switch-Device SW25 +U 1 1 5DA04574 +P 2550 6150 +F 0 "SW25" H 2550 6517 50 0000 C CNN +F 1 "Rotary_Encoder_Switch" H 2550 6426 50 0000 C CNN +F 2 "SofleRGB:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified" H 2400 6310 50 0001 C CNN +F 3 "~" H 2550 6410 50 0001 C CNN + 1 2550 6150 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR0103 +U 1 1 5DA35FE6 +P 1650 6250 +F 0 "#PWR0103" H 1650 6000 50 0001 C CNN +F 1 "GND" H 1655 6077 50 0000 C CNN +F 2 "" H 1650 6250 50 0001 C CNN +F 3 "" H 1650 6250 50 0001 C CNN + 1 1650 6250 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW5 +U 2 1 5F751B72 +P 10150 850 +F 0 "SW5" H 10150 677 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 1100 50 0001 C CNN +F 3 "" H 10150 1100 50 0001 C CNN + 2 10150 850 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW6 +U 2 1 5F752AB9 +P 10750 850 +F 0 "SW6" H 10750 1023 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 1100 50 0001 C CNN +F 3 "" H 10750 1100 50 0001 C CNN + 2 10750 850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW7 +U 2 1 5F754917 +P 7750 1300 +F 0 "SW7" H 7750 1127 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 1550 50 0001 C CNN +F 3 "" H 7750 1550 50 0001 C CNN + 2 7750 1300 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW8 +U 2 1 5F755BEC +P 8350 1300 +F 0 "SW8" H 8350 1473 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 1550 50 0001 C CNN +F 3 "" H 8350 1550 50 0001 C CNN + 2 8350 1300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW9 +U 2 1 5F756CE6 +P 8950 1300 +F 0 "SW9" H 8950 1127 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 1550 50 0001 C CNN +F 3 "" H 8950 1550 50 0001 C CNN + 2 8950 1300 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW10 +U 2 1 5F757ED7 +P 9550 1300 +F 0 "SW10" H 9550 1473 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 1550 50 0001 C CNN +F 3 "" H 9550 1550 50 0001 C CNN + 2 9550 1300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW11 +U 2 1 5F758F15 +P 10150 1300 +F 0 "SW11" H 10150 1127 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 1550 50 0001 C CNN +F 3 "" H 10150 1550 50 0001 C CNN + 2 10150 1300 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW12 +U 2 1 5F75A082 +P 10750 1300 +F 0 "SW12" H 10750 1473 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 1550 50 0001 C CNN +F 3 "" H 10750 1550 50 0001 C CNN + 2 10750 1300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D35 +U 1 1 5F7EF5F2 +P 4500 1550 +F 0 "D35" H 4500 1377 50 0000 C CNN +F 1 "LED_sk2812_SM" H 4500 1724 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 4500 1550 50 0001 C CNN +F 3 "" H 4500 1550 50 0001 C CNN + 1 4500 1550 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D34 +U 1 1 5F7EC8B3 +P 3750 1550 +F 0 "D34" H 3750 1377 50 0000 C CNN +F 1 "LED_sk2812_SM" H 3750 1724 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 3750 1550 50 0001 C CNN +F 3 "" H 3750 1550 50 0001 C CNN + 1 3750 1550 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D33 +U 1 1 5F7EC8AD +P 5300 900 +F 0 "D33" H 5300 1073 50 0000 C CNN +F 1 "LED_sk2812_SM" H 5300 1074 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 5300 900 50 0001 C CNN +F 3 "" H 5300 900 50 0001 C CNN + 1 5300 900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D32 +U 1 1 5F7E9258 +P 4500 900 +F 0 "D32" H 4500 1073 50 0000 C CNN +F 1 "LED_sk2812_SM" H 4500 1074 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 4500 900 50 0001 C CNN +F 3 "" H 4500 900 50 0001 C CNN + 1 4500 900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D31 +U 1 1 5F7E6561 +P 3750 900 +F 0 "D31" H 3750 1073 50 0000 C CNN +F 1 "LED_sk2812_SM" H 3750 1074 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 3750 900 50 0001 C CNN +F 3 "" H 3750 900 50 0001 C CNN + 1 3750 900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW1 +U 2 1 5F749FCB +P 7750 850 +F 0 "SW1" H 7750 677 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 1100 50 0001 C CNN +F 3 "" H 7750 1100 50 0001 C CNN + 2 7750 850 + -1 0 0 1 +$EndComp +NoConn ~ 7950 2250 +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW4 +U 1 1 5B722A11 +P 9000 3450 +F 0 "SW4" H 9000 3705 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 3614 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 3450 50 0001 C CNN +F 3 "" H 9000 3450 50 0000 C CNN + 1 9000 3450 + 1 0 0 -1 +$EndComp +Wire Wire Line + 4100 2900 4300 2900 +Wire Wire Line + 4300 2650 4300 2900 +Wire Wire Line + 4850 2550 5400 2550 +Wire Wire Line + 5400 2550 5400 2850 +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP9 +U 1 1 61D5D1D0 +P 4050 2550 +F 0 "JP9" H 4050 2500 50 0000 C CNN +F 1 "Jumper_NO_Small" H 4050 2644 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 4050 2550 50 0001 C CNN +F 3 "~" H 4050 2550 50 0001 C CNN + 1 4050 2550 + 1 0 0 -1 +$EndComp +Connection ~ 4200 2550 +Wire Wire Line + 4200 2550 4150 2550 +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP10 +U 1 1 620925F6 +P 6450 700 +F 0 "JP10" H 6450 650 50 0000 C CNN +F 1 "Jumper_NO_Small" H 6450 794 50 0001 C CNN +F 2 "SofleRGB:Jumper" H 6450 700 50 0001 C CNN +F 3 "~" H 6450 700 50 0001 C CNN + 1 6450 700 + 1 0 0 -1 +$EndComp +Wire Wire Line + 5500 1600 7100 1600 +Text GLabel 10950 3000 0 50 Input ~ 0 +BL +Text GLabel 6950 700 1 50 Input ~ 0 +BL +$EndSCHEMATC diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.sch-bak b/Sofle_RGB_v3/PCB/SofleKeyboard.sch-bak new file mode 100644 index 00000000..4820d0cf --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.sch-bak @@ -0,0 +1,2627 @@ +EESchema Schematic File Version 4 +EELAYER 30 0 +EELAYER END +$Descr A4 11693 8268 +encoding utf-8 +Sheet 1 1 +Title "" +Date "" +Rev "" +Comp "" +Comment1 "" +Comment2 "" +Comment3 "" +Comment4 "" +$EndDescr +Text GLabel 6050 3750 0 50 Input ~ 0 +row0 +Text GLabel 6050 4400 0 50 Input ~ 0 +row1 +Text GLabel 6050 5050 0 50 Input ~ 0 +row2 +Text GLabel 6050 5700 0 50 Input ~ 0 +row3 +Text GLabel 6050 6350 0 50 Input ~ 0 +row4 +Text GLabel 10300 3450 1 50 Input ~ 0 +col0 +Text GLabel 9500 3450 1 50 Input ~ 0 +col1 +Text GLabel 8700 3450 1 50 Input ~ 0 +col2 +Text GLabel 7900 3450 1 50 Input ~ 0 +col3 +Text GLabel 7100 3450 1 50 Input ~ 0 +col4 +Text GLabel 6300 3450 1 50 Input ~ 0 +col5 +Wire Wire Line + 6050 6350 6900 6350 +Text GLabel 2400 1950 2 50 Input ~ 0 +col5 +Text GLabel 2400 1850 2 50 Input ~ 0 +col4 +Text GLabel 2400 1750 2 50 Input ~ 0 +col3 +Text GLabel 2400 1650 2 50 Input ~ 0 +col2 +Text GLabel 2400 1550 2 50 Input ~ 0 +col1 +Text GLabel 2400 1450 2 50 Input ~ 0 +col0 +NoConn ~ 1100 1450 +Text GLabel 2400 1050 2 50 Input ~ 0 +RESET +NoConn ~ 2400 850 +Text GLabel 1100 850 0 50 Input ~ 0 +LED +Text GLabel 1100 1350 0 50 Input ~ 0 +SCL +Text GLabel 1100 1250 0 50 Input ~ 0 +SDA +Text GLabel 1100 1550 0 50 Input ~ 0 +row0 +Text GLabel 1100 1650 0 50 Input ~ 0 +row1 +Text GLabel 1100 1750 0 50 Input ~ 0 +row2 +Text GLabel 1100 1850 0 50 Input ~ 0 +row3 +Text GLabel 1100 1950 0 50 Input ~ 0 +row4 +Text GLabel 2850 3950 3 50 Input ~ 0 +SDA +Text GLabel 2750 2300 2 50 Input ~ 0 +LED +Text GLabel 1200 2450 2 50 Input ~ 0 +RESET +Text GLabel 3000 3950 3 50 Input ~ 0 +SCL +Connection ~ 8500 3750 +Wire Wire Line + 8500 3750 9300 3750 +Wire Wire Line + 7100 3450 7100 4100 +Wire Wire Line + 7700 3750 8500 3750 +Connection ~ 8700 5400 +Connection ~ 9300 5700 +Wire Wire Line + 9300 5700 10100 5700 +Connection ~ 7900 5400 +Connection ~ 8500 5700 +Wire Wire Line + 8500 5700 9300 5700 +Connection ~ 7100 5400 +Wire Wire Line + 7100 5400 7100 6050 +Wire Wire Line + 7700 5700 8500 5700 +Connection ~ 7100 4750 +Wire Wire Line + 7100 4750 7100 5400 +Wire Wire Line + 7700 5050 8500 5050 +Connection ~ 7900 4750 +Wire Wire Line + 7900 4750 7900 5400 +Connection ~ 8500 5050 +Wire Wire Line + 8500 5050 9300 5050 +Connection ~ 8700 4750 +Wire Wire Line + 8700 4750 8700 5400 +Connection ~ 9300 5050 +Wire Wire Line + 9300 5050 10100 5050 +Connection ~ 8700 4100 +Wire Wire Line + 8700 4100 8700 4750 +Connection ~ 9300 4400 +Wire Wire Line + 9300 4400 10100 4400 +Wire Wire Line + 8700 3450 8700 4100 +Connection ~ 7900 4100 +Wire Wire Line + 7900 4100 7900 4750 +Connection ~ 8500 4400 +Wire Wire Line + 8500 4400 9300 4400 +Wire Wire Line + 7900 3450 7900 4100 +Connection ~ 7100 4100 +Wire Wire Line + 7100 4100 7100 4750 +Wire Wire Line + 7700 4400 8500 4400 +Connection ~ 9500 4100 +Connection ~ 10100 4400 +Wire Wire Line + 10100 4400 10900 4400 +Wire Wire Line + 9500 3450 9500 4100 +Connection ~ 10100 5050 +Wire Wire Line + 10100 5050 10900 5050 +Wire Wire Line + 9500 4100 9500 4750 +Connection ~ 10100 5700 +Wire Wire Line + 10100 5700 10900 5700 +Wire Wire Line + 9500 5400 9500 6050 +Connection ~ 9300 6350 +Wire Wire Line + 9300 6350 10100 6350 +Wire Wire Line + 8700 5400 8700 6050 +Connection ~ 8500 6350 +Wire Wire Line + 8500 6350 9300 6350 +Wire Wire Line + 7900 5400 7900 6050 +Connection ~ 7700 6350 +Wire Wire Line + 7700 6350 8500 6350 +Connection ~ 6900 6350 +Wire Wire Line + 6900 6350 7700 6350 +Wire Wire Line + 9500 5400 9500 4750 +Connection ~ 9500 5400 +Connection ~ 9500 4750 +Wire Wire Line + 10300 4750 10300 5400 +Wire Wire Line + 10300 4750 10300 4100 +Connection ~ 10300 4750 +Wire Wire Line + 10300 4100 10300 3450 +Connection ~ 10300 4100 +Wire Wire Line + 6300 3450 6300 4100 +Wire Wire Line + 6300 4100 6300 4750 +Connection ~ 6300 4100 +Wire Wire Line + 6300 4750 6300 5400 +Connection ~ 6300 4750 +Wire Wire Line + 6300 5400 6300 6050 +Connection ~ 6300 5400 +Wire Wire Line + 10100 3750 10900 3750 +Wire Wire Line + 10100 3750 9300 3750 +Connection ~ 10100 3750 +Connection ~ 9300 3750 +Wire Wire Line + 7700 3750 6900 3750 +Connection ~ 7700 3750 +Wire Wire Line + 6900 3750 6050 3750 +Connection ~ 6900 3750 +Wire Wire Line + 7700 4400 6900 4400 +Connection ~ 7700 4400 +Wire Wire Line + 6900 4400 6050 4400 +Connection ~ 6900 4400 +Wire Wire Line + 7700 5050 6900 5050 +Connection ~ 7700 5050 +Wire Wire Line + 6900 5050 6050 5050 +Connection ~ 6900 5050 +Wire Wire Line + 7700 5700 6900 5700 +Connection ~ 7700 5700 +Wire Wire Line + 6900 5700 6050 5700 +Connection ~ 6900 5700 +Wire Wire Line + 1100 1050 1100 1150 +Wire Wire Line + 1100 1150 850 1150 +Connection ~ 1100 1150 +Wire Wire Line + 1700 3200 1600 3200 +Wire Wire Line + 1600 3300 1700 3300 +Wire Wire Line + 1600 3400 2000 3400 +Wire Wire Line + 1600 3050 2000 3050 +Wire Wire Line + 1700 3000 1700 3200 +Wire Wire Line + 1700 3300 1700 3450 +Text GLabel 1100 950 0 50 Input ~ 0 +DATA +Text GLabel 2600 3400 2 50 Input ~ 0 +DATA +Wire Wire Line + 1000 3800 1150 3800 +Wire Wire Line + 1000 3900 1100 3900 +Wire Wire Line + 1000 4000 1050 4000 +Wire Wire Line + 1200 4100 1000 4100 +Wire Wire Line + 1000 4100 1000 4550 +Wire Wire Line + 1000 4550 1200 4550 +Connection ~ 1000 4100 +Wire Wire Line + 1050 4000 1050 4450 +Wire Wire Line + 1050 4450 1200 4450 +Connection ~ 1050 4000 +Wire Wire Line + 1050 4000 1200 4000 +Wire Wire Line + 1100 3900 1100 4350 +Wire Wire Line + 1100 4350 1200 4350 +Connection ~ 1100 3900 +Wire Wire Line + 1100 3900 1200 3900 +Wire Wire Line + 1150 3800 1150 4250 +Wire Wire Line + 1150 4250 1200 4250 +Connection ~ 1150 3800 +Wire Wire Line + 1150 3800 1200 3800 +Text GLabel 1400 4350 2 50 Input ~ 0 +SCL +Text GLabel 1400 4250 2 50 Input ~ 0 +SDA +Text GLabel 1400 4000 2 50 Input ~ 0 +SCL +Text GLabel 1400 4100 2 50 Input ~ 0 +SDA +Wire Wire Line + 2400 950 2700 950 +Wire Wire Line + 2400 1150 2700 1150 +Connection ~ 2000 3400 +Wire Wire Line + 10300 5400 10300 6050 +Connection ~ 10300 5400 +Wire Wire Line + 10100 6350 10900 6350 +Connection ~ 10100 6350 +Text GLabel 3150 6050 2 50 Input ~ 0 +SW25A +Text GLabel 3150 6250 2 50 Input ~ 0 +SW25B +Wire Wire Line + 2850 6050 3150 6050 +Wire Wire Line + 2850 6250 3150 6250 +Text GLabel 6350 6050 2 50 Input ~ 0 +SW25A +Text GLabel 6900 5900 0 50 Input ~ 0 +SW25B +Wire Wire Line + 6900 5900 6900 6050 +Wire Wire Line + 6300 6050 6350 6050 +Text GLabel 2400 1250 2 50 Input ~ 0 +ENCA +Text GLabel 2400 1350 2 50 Input ~ 0 +ENCB +Text GLabel 2100 6050 0 50 Input ~ 0 +ENCA +Text GLabel 2100 6250 0 50 Input ~ 0 +ENCB +Wire Wire Line + 2100 6250 2250 6250 +Wire Wire Line + 2100 6050 2250 6050 +Wire Wire Line + 2250 6150 1650 6150 +Wire Wire Line + 1650 6150 1650 6250 +Text Label 1800 3400 0 50 ~ 0 +i2c_d +Text Label 1750 3050 0 50 ~ 0 +i2c_c +Wire Wire Line + 5100 850 4850 850 +Wire Wire Line + 4850 850 4850 950 +Wire Wire Line + 4850 950 4700 950 +Wire Wire Line + 4300 850 4100 850 +Wire Wire Line + 4100 850 4100 950 +Wire Wire Line + 4100 950 3950 950 +Wire Wire Line + 3550 850 3350 850 +Wire Wire Line + 3350 1500 3550 1500 +Wire Wire Line + 3950 1600 4150 1600 +Wire Wire Line + 4150 1600 4150 1500 +Wire Wire Line + 4150 1500 4300 1500 +Wire Wire Line + 4700 1600 4900 1600 +Wire Wire Line + 4900 1600 4900 1500 +Wire Wire Line + 4900 1500 5100 1500 +Wire Wire Line + 5700 600 5500 600 +Wire Wire Line + 3950 600 3950 850 +Wire Wire Line + 4700 850 4700 600 +Connection ~ 4700 600 +Wire Wire Line + 4700 600 3950 600 +Wire Wire Line + 5500 850 5500 600 +Connection ~ 5500 600 +Wire Wire Line + 5500 600 4700 600 +Wire Wire Line + 3550 2000 4300 2000 +Connection ~ 4300 2000 +Wire Wire Line + 3550 2000 3250 2000 +Wire Wire Line + 3250 2000 3250 1850 +Connection ~ 3550 2000 +Wire Wire Line + 3350 850 3350 1500 +Wire Wire Line + 3950 1500 3950 1200 +Wire Wire Line + 3950 1200 3550 1200 +Wire Wire Line + 3550 1200 3550 950 +Wire Wire Line + 3950 1200 4300 1200 +Wire Wire Line + 4300 1200 4300 950 +Connection ~ 3950 1200 +Wire Wire Line + 4300 1200 4700 1200 +Wire Wire Line + 4700 1200 4700 1500 +Connection ~ 4300 1200 +Wire Wire Line + 4700 1200 5100 1200 +Wire Wire Line + 5100 1200 5100 950 +Connection ~ 4700 1200 +Connection ~ 5100 1200 +Wire Wire Line + 6350 700 6350 950 +Wire Wire Line + 5500 950 6350 950 +Text Label 5900 950 0 50 ~ 0 +underglow +Wire Wire Line + 5500 1500 5500 1200 +Wire Wire Line + 5100 1200 5500 1200 +Wire Wire Line + 6550 700 7100 700 +Wire Wire Line + 4300 2000 5100 2000 +Wire Wire Line + 3550 1600 3550 2000 +Wire Wire Line + 4300 1600 4300 2000 +Wire Wire Line + 5100 1600 5100 2000 +Text GLabel 4200 2500 1 50 Input ~ 0 +LED +Wire Wire Line + 4200 2500 4200 2550 +Wire Wire Line + 4450 2650 4300 2650 +Wire Wire Line + 4850 2650 5000 2650 +Wire Wire Line + 4450 2550 4200 2550 +Text GLabel 5000 2650 2 50 Input ~ 0 +lights +Text GLabel 6300 950 3 50 Input ~ 0 +lights +Text GLabel 3950 2550 0 50 Input ~ 0 +lights +Wire Wire Line + 5500 1200 5900 1200 +Connection ~ 5500 1200 +Wire Wire Line + 7100 1600 7100 700 +Wire Wire Line + 7550 1900 7550 2150 +Wire Wire Line + 7950 1900 7550 1900 +Wire Wire Line + 7950 1800 7950 1900 +Wire Wire Line + 7550 1450 7550 1700 +Wire Wire Line + 7950 1450 7550 1450 +Wire Wire Line + 7950 1350 7950 1450 +Wire Wire Line + 7550 1000 7550 1250 +Wire Wire Line + 7950 1000 7550 1000 +Wire Wire Line + 7950 900 7950 1000 +Wire Wire Line + 7500 800 7550 800 +Wire Wire Line + 7500 600 7500 800 +Wire Wire Line + 8150 600 7500 600 +Wire Wire Line + 8150 800 8150 600 +Wire Wire Line + 8550 1000 8550 900 +Wire Wire Line + 8150 1000 8550 1000 +Wire Wire Line + 8150 1250 8150 1000 +Wire Wire Line + 8550 1450 8550 1350 +Wire Wire Line + 8150 1450 8550 1450 +Wire Wire Line + 8150 1700 8150 1450 +Wire Wire Line + 8550 1900 8550 1800 +Wire Wire Line + 8150 1900 8550 1900 +Wire Wire Line + 8150 2150 8150 1900 +Wire Wire Line + 8550 2350 8550 2250 +Wire Wire Line + 8150 2350 8550 2350 +Wire Wire Line + 8150 2600 8150 2350 +Wire Wire Line + 8550 2800 8550 2700 +Wire Wire Line + 9150 2800 8550 2800 +Wire Wire Line + 9150 2700 9150 2800 +Wire Wire Line + 8750 2350 8750 2600 +Wire Wire Line + 9150 2350 8750 2350 +Wire Wire Line + 9150 2250 9150 2350 +Wire Wire Line + 8750 1900 8750 2150 +Wire Wire Line + 9150 1900 8750 1900 +Wire Wire Line + 9150 1800 9150 1900 +Wire Wire Line + 8750 1450 8750 1700 +Wire Wire Line + 9150 1450 8750 1450 +Wire Wire Line + 9150 1350 9150 1450 +Wire Wire Line + 8750 1000 8750 1250 +Wire Wire Line + 9150 1000 8750 1000 +Wire Wire Line + 9150 900 9150 1000 +Wire Wire Line + 8700 800 8750 800 +Wire Wire Line + 8700 600 8700 800 +Wire Wire Line + 9350 600 8700 600 +Wire Wire Line + 9350 800 9350 600 +Wire Wire Line + 9750 1000 9750 900 +Wire Wire Line + 9350 1000 9750 1000 +Wire Wire Line + 9350 1250 9350 1000 +Wire Wire Line + 9750 1450 9750 1350 +Wire Wire Line + 9350 1450 9750 1450 +Wire Wire Line + 9350 1700 9350 1450 +Wire Wire Line + 9750 1900 9750 1800 +Wire Wire Line + 9350 1900 9750 1900 +Wire Wire Line + 9350 2150 9350 1900 +Wire Wire Line + 9750 2350 9750 2250 +Wire Wire Line + 9350 2350 9750 2350 +Wire Wire Line + 9350 2600 9350 2350 +Wire Wire Line + 9250 2700 9250 2900 +Connection ~ 9250 2700 +Wire Wire Line + 9350 2700 9250 2700 +Wire Wire Line + 9250 2600 9250 2700 +Connection ~ 9250 2600 +Wire Wire Line + 9150 2600 9250 2600 +Wire Wire Line + 9250 2250 9250 2600 +Connection ~ 9250 2250 +Wire Wire Line + 9350 2250 9250 2250 +Wire Wire Line + 9250 2150 9250 2250 +Connection ~ 9250 2150 +Wire Wire Line + 9150 2150 9250 2150 +Wire Wire Line + 9250 1800 9250 2150 +Connection ~ 9250 1800 +Wire Wire Line + 9350 1800 9250 1800 +Wire Wire Line + 9250 1700 9250 1800 +Connection ~ 9250 1700 +Wire Wire Line + 9150 1700 9250 1700 +Wire Wire Line + 9250 1350 9250 1700 +Connection ~ 9250 1350 +Wire Wire Line + 9350 1350 9250 1350 +Wire Wire Line + 9250 1250 9250 1350 +Connection ~ 9250 1250 +Wire Wire Line + 9150 1250 9250 1250 +Wire Wire Line + 9250 900 9250 1250 +Connection ~ 9250 900 +Wire Wire Line + 9350 900 9250 900 +Wire Wire Line + 9250 800 9250 900 +Wire Wire Line + 9150 800 9250 800 +Wire Wire Line + 8650 800 8650 900 +Connection ~ 8650 800 +Wire Wire Line + 8550 800 8650 800 +Wire Wire Line + 8650 900 8650 1250 +Connection ~ 8650 900 +Wire Wire Line + 8750 900 8650 900 +Wire Wire Line + 8650 1250 8650 1350 +Connection ~ 8650 1250 +Wire Wire Line + 8550 1250 8650 1250 +Wire Wire Line + 8650 1350 8650 1700 +Connection ~ 8650 1350 +Wire Wire Line + 8750 1350 8650 1350 +Wire Wire Line + 8650 1700 8650 1800 +Connection ~ 8650 1700 +Wire Wire Line + 8550 1700 8650 1700 +Wire Wire Line + 8650 1800 8650 2150 +Connection ~ 8650 1800 +Wire Wire Line + 8750 1800 8650 1800 +Wire Wire Line + 8650 2250 8650 2600 +Connection ~ 8650 2250 +Wire Wire Line + 8750 2250 8650 2250 +Wire Wire Line + 8650 2150 8650 2250 +Connection ~ 8650 2150 +Wire Wire Line + 8550 2150 8650 2150 +Wire Wire Line + 8650 2600 8650 2700 +Connection ~ 8650 2600 +Wire Wire Line + 8550 2600 8650 2600 +Wire Wire Line + 8650 2700 8750 2700 +Wire Wire Line + 8650 550 8650 800 +Wire Wire Line + 7450 900 7450 1350 +Connection ~ 7450 900 +Wire Wire Line + 7550 900 7450 900 +Wire Wire Line + 7450 1350 7450 1800 +Connection ~ 7450 1350 +Wire Wire Line + 7550 1350 7450 1350 +Wire Wire Line + 7450 1800 7450 2250 +Connection ~ 7450 1800 +Wire Wire Line + 7550 1800 7450 1800 +Wire Wire Line + 7450 2250 7550 2250 +Wire Wire Line + 7450 550 7450 900 +Wire Wire Line + 8050 900 8050 1250 +Connection ~ 8050 900 +Wire Wire Line + 8050 800 8050 900 +Wire Wire Line + 7950 800 8050 800 +Connection ~ 8050 1250 +Wire Wire Line + 7950 1250 8050 1250 +Wire Wire Line + 8050 1350 8050 1250 +Connection ~ 8050 1350 +Wire Wire Line + 8150 1350 8050 1350 +Wire Wire Line + 8050 1700 8050 1350 +Connection ~ 8050 1700 +Wire Wire Line + 7950 1700 8050 1700 +Wire Wire Line + 8050 1800 8050 1700 +Connection ~ 8050 1800 +Wire Wire Line + 8150 1800 8050 1800 +Wire Wire Line + 8050 2150 8050 1800 +Connection ~ 8050 2150 +Wire Wire Line + 7950 2150 8050 2150 +Wire Wire Line + 8050 2250 8050 2150 +Connection ~ 8050 2250 +Wire Wire Line + 8150 2250 8050 2250 +Wire Wire Line + 8050 2700 8050 2250 +Connection ~ 8050 2700 +Wire Wire Line + 8150 2700 8050 2700 +Wire Wire Line + 8050 900 8150 900 +Wire Wire Line + 8050 2900 8050 2700 +Wire Wire Line + 10450 2600 10450 2700 +Connection ~ 10450 2600 +Wire Wire Line + 10350 2600 10450 2600 +Wire Wire Line + 10450 2150 10450 2250 +Connection ~ 10450 2150 +Wire Wire Line + 10450 1800 10450 2150 +Wire Wire Line + 10350 2150 10450 2150 +Wire Wire Line + 10450 1700 10450 1800 +Connection ~ 10450 1700 +Wire Wire Line + 10350 1700 10450 1700 +Wire Wire Line + 10450 1250 10450 1350 +Connection ~ 10450 1250 +Wire Wire Line + 10350 1250 10450 1250 +Wire Wire Line + 10450 900 10450 1250 +Connection ~ 10450 900 +Wire Wire Line + 10450 800 10450 900 +Wire Wire Line + 10350 800 10450 800 +Wire Wire Line + 9850 900 9850 800 +Connection ~ 9850 900 +Wire Wire Line + 9950 900 9850 900 +Wire Wire Line + 9850 800 9850 550 +Connection ~ 9850 800 +Wire Wire Line + 9750 800 9850 800 +Wire Wire Line + 9850 1350 9850 1250 +Connection ~ 9850 1350 +Wire Wire Line + 9950 1350 9850 1350 +Wire Wire Line + 9850 1250 9850 900 +Connection ~ 9850 1250 +Wire Wire Line + 9750 1250 9850 1250 +Wire Wire Line + 9850 1800 9850 1700 +Connection ~ 9850 1800 +Wire Wire Line + 9950 1800 9850 1800 +Wire Wire Line + 9850 1700 9850 1350 +Connection ~ 9850 1700 +Wire Wire Line + 9750 1700 9850 1700 +Wire Wire Line + 9850 2150 9850 1800 +Connection ~ 9850 2150 +Wire Wire Line + 9750 2150 9850 2150 +Wire Wire Line + 9850 2250 9850 2150 +Connection ~ 9850 2250 +Wire Wire Line + 9950 2250 9850 2250 +Wire Wire Line + 9850 2600 9850 2250 +Connection ~ 9850 2600 +Wire Wire Line + 9750 2600 9850 2600 +Wire Wire Line + 9850 2700 9850 2600 +Wire Wire Line + 9950 2700 9850 2700 +Wire Wire Line + 9750 2800 9750 2700 +Wire Wire Line + 10350 2800 9750 2800 +Wire Wire Line + 10350 2700 10350 2800 +Wire Wire Line + 9900 2600 9950 2600 +Wire Wire Line + 9900 2350 9900 2600 +Wire Wire Line + 10350 2350 9900 2350 +Wire Wire Line + 10350 2250 10350 2350 +Wire Wire Line + 9900 2150 9950 2150 +Wire Wire Line + 9900 1900 9900 2150 +Wire Wire Line + 10350 1900 9900 1900 +Wire Wire Line + 10350 1800 10350 1900 +Wire Wire Line + 9900 1700 9950 1700 +Wire Wire Line + 9900 1450 9900 1700 +Wire Wire Line + 10350 1450 9900 1450 +Wire Wire Line + 10350 1350 10350 1450 +Wire Wire Line + 9900 1250 9950 1250 +Wire Wire Line + 9900 1000 9900 1250 +Wire Wire Line + 10350 1000 9900 1000 +Wire Wire Line + 10350 900 10350 1000 +Wire Wire Line + 9900 800 9950 800 +Wire Wire Line + 9900 600 9900 800 +Wire Wire Line + 10550 600 9900 600 +Wire Wire Line + 10550 800 10550 600 +Wire Wire Line + 10950 1000 10950 900 +Wire Wire Line + 10550 1000 10950 1000 +Wire Wire Line + 10550 1250 10550 1000 +Wire Wire Line + 10950 1450 10950 1350 +Wire Wire Line + 10550 1450 10950 1450 +Wire Wire Line + 10550 1700 10550 1450 +Wire Wire Line + 10950 1900 10950 1800 +Wire Wire Line + 10550 1900 10950 1900 +Wire Wire Line + 10550 2150 10550 1900 +Wire Wire Line + 10950 2350 10950 2250 +Wire Wire Line + 10550 2350 10950 2350 +Wire Wire Line + 10550 2600 10550 2350 +Wire Wire Line + 10950 2700 10950 3000 +Wire Wire Line + 10450 2700 10450 2900 +Connection ~ 10450 2700 +Wire Wire Line + 10550 2700 10450 2700 +Wire Wire Line + 10450 2250 10450 2600 +Connection ~ 10450 2250 +Wire Wire Line + 10550 2250 10450 2250 +Connection ~ 10450 1800 +Wire Wire Line + 10550 1800 10450 1800 +Connection ~ 10450 1350 +Wire Wire Line + 10450 1350 10450 1700 +Wire Wire Line + 10450 1350 10550 1350 +Wire Wire Line + 10550 900 10450 900 +Connection ~ 11050 2150 +Wire Wire Line + 11050 2600 10950 2600 +Wire Wire Line + 11050 2150 11050 2600 +Connection ~ 11050 1700 +Wire Wire Line + 11050 2150 10950 2150 +Wire Wire Line + 11050 1700 11050 2150 +Connection ~ 11050 1250 +Wire Wire Line + 11050 1700 10950 1700 +Wire Wire Line + 11050 1250 11050 1700 +Connection ~ 11050 800 +Wire Wire Line + 11050 1250 10950 1250 +Wire Wire Line + 11050 800 11050 1250 +Wire Wire Line + 11050 800 11050 700 +Wire Wire Line + 10950 800 11050 800 +$Comp +L SofleKeyboard:LED_sk2812_SM D36 +U 1 1 5F7EF5F8 +P 5300 1550 +F 0 "D36" H 5300 1377 50 0000 C CNN +F 1 "LED_sk2812_SM" H 5300 1724 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 5300 1550 50 0001 C CNN +F 3 "" H 5300 1550 50 0001 C CNN + 1 5300 1550 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D37 +U 1 1 5F918D28 +P 4650 2600 +F 0 "D37" H 4650 2427 50 0000 C CNN +F 1 "LED_sk2812_SM" H 4650 2774 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 4650 2600 50 0001 C CNN +F 3 "" H 4650 2600 50 0001 C CNN + 1 4650 2600 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW1 +U 1 1 5B7225DA +P 6600 3450 +F 0 "SW1" H 6600 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 3450 50 0001 C CNN +F 3 "" H 6600 3450 50 0000 C CNN + 1 6600 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW2 +U 2 1 5F74DC46 +P 8350 850 +F 0 "SW2" H 8350 1023 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 1100 50 0001 C CNN +F 3 "" H 8350 1100 50 0001 C CNN + 2 8350 850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW2 +U 1 1 5B7227CD +P 7400 3450 +F 0 "SW2" H 7400 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 3450 50 0001 C CNN +F 3 "" H 7400 3450 50 0000 C CNN + 1 7400 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW3 +U 2 1 5F74EA54 +P 8950 850 +F 0 "SW3" H 8950 677 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 1100 50 0001 C CNN +F 3 "" H 8950 1100 50 0001 C CNN + 2 8950 850 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW4 +U 2 1 5F74FBCC +P 9550 850 +F 0 "SW4" H 9550 1023 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 1100 50 0001 C CNN +F 3 "" H 9550 1100 50 0001 C CNN + 2 9550 850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR024 +U 1 1 5FEF0394 +P 8050 2900 +F 0 "#PWR024" H 8050 2650 50 0001 C CNN +F 1 "GND" H 8055 2727 50 0000 C CNN +F 2 "" H 8050 2900 50 0001 C CNN +F 3 "" H 8050 2900 50 0001 C CNN + 1 8050 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR025 +U 1 1 5FEEFF47 +P 9250 2900 +F 0 "#PWR025" H 9250 2650 50 0001 C CNN +F 1 "GND" H 9255 2727 50 0000 C CNN +F 2 "" H 9250 2900 50 0001 C CNN +F 3 "" H 9250 2900 50 0001 C CNN + 1 9250 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR026 +U 1 1 5FEEF6D8 +P 10450 2900 +F 0 "#PWR026" H 10450 2650 50 0001 C CNN +F 1 "GND" H 10455 2727 50 0000 C CNN +F 2 "" H 10450 2900 50 0001 C CNN +F 3 "" H 10450 2900 50 0001 C CNN + 1 10450 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR015 +U 1 1 5FEEF38A +P 7450 550 +F 0 "#PWR015" H 7450 400 50 0001 C CNN +F 1 "VCC" H 7467 723 50 0000 C CNN +F 2 "" H 7450 550 50 0001 C CNN +F 3 "" H 7450 550 50 0001 C CNN + 1 7450 550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR016 +U 1 1 5FEEEC68 +P 8650 550 +F 0 "#PWR016" H 8650 400 50 0001 C CNN +F 1 "VCC" H 8667 723 50 0000 C CNN +F 2 "" H 8650 550 50 0001 C CNN +F 3 "" H 8650 550 50 0001 C CNN + 1 8650 550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR017 +U 1 1 5FEEE81F +P 9850 550 +F 0 "#PWR017" H 9850 400 50 0001 C CNN +F 1 "VCC" H 9867 723 50 0000 C CNN +F 2 "" H 9850 550 50 0001 C CNN +F 3 "" H 9850 550 50 0001 C CNN + 1 9850 550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR019 +U 1 1 5FBCA77E +P 11050 700 +F 0 "#PWR019" H 11050 550 50 0001 C CNN +F 1 "VCC" H 11067 873 50 0000 C CNN +F 2 "" H 11050 700 50 0001 C CNN +F 3 "" H 11050 700 50 0001 C CNN + 1 11050 700 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR023 +U 1 1 5FB348BA +P 5400 2850 +F 0 "#PWR023" H 5400 2600 50 0001 C CNN +F 1 "GND" H 5405 2677 50 0000 C CNN +F 2 "" H 5400 2850 50 0001 C CNN +F 3 "" H 5400 2850 50 0001 C CNN + 1 5400 2850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR022 +U 1 1 5FB33FDA +P 4100 2900 +F 0 "#PWR022" H 4100 2750 50 0001 C CNN +F 1 "VCC" H 4117 3073 50 0000 C CNN +F 2 "" H 4100 2900 50 0001 C CNN +F 3 "" H 4100 2900 50 0001 C CNN + 1 4100 2900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR021 +U 1 1 5F89E5EE +P 3250 1850 +F 0 "#PWR021" H 3250 1700 50 0001 C CNN +F 1 "VCC" H 3267 2023 50 0000 C CNN +F 2 "" H 3250 1850 50 0001 C CNN +F 3 "" H 3250 1850 50 0001 C CNN + 1 3250 1850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR020 +U 1 1 5F84539D +P 5900 1200 +F 0 "#PWR020" H 5900 950 50 0001 C CNN +F 1 "GND" H 5905 1027 50 0000 C CNN +F 2 "" H 5900 1200 50 0001 C CNN +F 3 "" H 5900 1200 50 0001 C CNN + 1 5900 1200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR018 +U 1 1 5F843EAE +P 5700 600 +F 0 "#PWR018" H 5700 450 50 0001 C CNN +F 1 "VCC" H 5717 773 50 0000 C CNN +F 2 "" H 5700 600 50 0001 C CNN +F 3 "" H 5700 600 50 0001 C CNN + 1 5700 600 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW30 +U 2 1 5F7D72C1 +P 10750 2650 +F 0 "SW30" H 10750 2823 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 2900 50 0001 C CNN +F 3 "" H 10750 2900 50 0001 C CNN + 2 10750 2650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW26 +U 2 1 5F7D72BB +P 8350 2650 +F 0 "SW26" H 8350 2823 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 2900 50 0001 C CNN +F 3 "" H 8350 2900 50 0001 C CNN + 2 8350 2650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW27 +U 2 1 5F7D72B5 +P 8950 2650 +F 0 "SW27" H 8950 2477 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 2900 50 0001 C CNN +F 3 "" H 8950 2900 50 0001 C CNN + 2 8950 2650 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW28 +U 2 1 5F7D72AF +P 9550 2650 +F 0 "SW28" H 9550 2823 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 2900 50 0001 C CNN +F 3 "" H 9550 2900 50 0001 C CNN + 2 9550 2650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW29 +U 2 1 5F7D72A9 +P 10150 2650 +F 0 "SW29" H 10150 2477 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 2924 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 2900 50 0001 C CNN +F 3 "" H 10150 2900 50 0001 C CNN + 2 10150 2650 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW13 +U 2 1 5F7D01B3 +P 7750 1750 +F 0 "SW13" H 7750 1577 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 2000 50 0001 C CNN +F 3 "" H 7750 2000 50 0001 C CNN + 2 7750 1750 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW14 +U 2 1 5F7D01AD +P 8350 1750 +F 0 "SW14" H 8350 1923 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 2000 50 0001 C CNN +F 3 "" H 8350 2000 50 0001 C CNN + 2 8350 1750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW15 +U 2 1 5F7D01A7 +P 8950 1750 +F 0 "SW15" H 8950 1577 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 2000 50 0001 C CNN +F 3 "" H 8950 2000 50 0001 C CNN + 2 8950 1750 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW16 +U 2 1 5F7D01A1 +P 9550 1750 +F 0 "SW16" H 9550 1923 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 2000 50 0001 C CNN +F 3 "" H 9550 2000 50 0001 C CNN + 2 9550 1750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW17 +U 2 1 5F7D019B +P 10150 1750 +F 0 "SW17" H 10150 1577 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 2000 50 0001 C CNN +F 3 "" H 10150 2000 50 0001 C CNN + 2 10150 1750 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW18 +U 2 1 5F7D0195 +P 10750 1750 +F 0 "SW18" H 10750 1923 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 2024 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 2000 50 0001 C CNN +F 3 "" H 10750 2000 50 0001 C CNN + 2 10750 1750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW19 +U 2 1 5F7D018F +P 7750 2200 +F 0 "SW19" H 7750 2027 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 2450 50 0001 C CNN +F 3 "" H 7750 2450 50 0001 C CNN + 2 7750 2200 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW20 +U 2 1 5F7D0189 +P 8350 2200 +F 0 "SW20" H 8350 2373 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 2450 50 0001 C CNN +F 3 "" H 8350 2450 50 0001 C CNN + 2 8350 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW21 +U 2 1 5F7D0183 +P 8950 2200 +F 0 "SW21" H 8950 2027 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 2450 50 0001 C CNN +F 3 "" H 8950 2450 50 0001 C CNN + 2 8950 2200 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW22 +U 2 1 5F7D017D +P 9550 2200 +F 0 "SW22" H 9550 2373 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 2450 50 0001 C CNN +F 3 "" H 9550 2450 50 0001 C CNN + 2 9550 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW23 +U 2 1 5F7D0177 +P 10150 2200 +F 0 "SW23" H 10150 2027 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 2450 50 0001 C CNN +F 3 "" H 10150 2450 50 0001 C CNN + 2 10150 2200 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW24 +U 2 1 5F7D0171 +P 10750 2200 +F 0 "SW24" H 10750 2373 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 2474 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 2450 50 0001 C CNN +F 3 "" H 10750 2450 50 0001 C CNN + 2 10750 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:ProMicro_2-Lily58-cache-Lily58_Pro-rescue U1 +U 1 1 5B722440 +P 1750 1400 +F 0 "U1" H 1750 2100 60 0000 C CNN +F 1 "ProMicro" H 1750 700 60 0000 C CNN +F 2 "SofleKeyboard-footprint:ProMicro" H 1850 350 60 0001 C CNN +F 3 "" H 1850 350 60 0000 C CNN + 1 1750 1400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW26 +U 1 1 5B722582 +P 7400 6050 +F 0 "SW26" H 7400 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 6050 50 0001 C CNN +F 3 "" H 7400 6050 50 0000 C CNN + 1 7400 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D1 +U 1 1 5B7226E7 +P 6900 3600 +F 0 "D1" V 6946 3521 50 0000 R CNN +F 1 "D" V 6855 3521 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 6900 3600 50 0001 C CNN +F 3 "" H 6900 3600 50 0001 C CNN + 1 6900 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D2 +U 1 1 5B722847 +P 7700 3600 +F 0 "D2" V 7746 3521 50 0000 R CNN +F 1 "D" V 7655 3521 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 7700 3600 50 0001 C CNN +F 3 "" H 7700 3600 50 0001 C CNN + 1 7700 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW3 +U 1 1 5B7228F7 +P 8200 3450 +F 0 "SW3" H 8200 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 3450 50 0001 C CNN +F 3 "" H 8200 3450 50 0000 C CNN + 1 8200 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D3 +U 1 1 5B722950 +P 8500 3600 +F 0 "D3" V 8546 3521 50 0000 R CNN +F 1 "D" V 8455 3521 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 8500 3600 50 0001 C CNN +F 3 "" H 8500 3600 50 0001 C CNN + 1 8500 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D4 +U 1 1 5B722A8F +P 9300 3600 +F 0 "D4" V 9346 3521 50 0000 R CNN +F 1 "D" V 9255 3521 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 9300 3600 50 0001 C CNN +F 3 "" H 9300 3600 50 0001 C CNN + 1 9300 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW5 +U 1 1 5B722B51 +P 9800 3450 +F 0 "SW5" H 9800 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 3350 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 3450 50 0001 C CNN +F 3 "" H 9800 3450 50 0000 C CNN + 1 9800 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D5 +U 1 1 5B722BAD +P 10100 3600 +F 0 "D5" V 10146 3521 50 0000 R CNN +F 1 "D" V 10055 3521 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10100 3600 50 0001 C CNN +F 3 "" H 10100 3600 50 0001 C CNN + 1 10100 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW6 +U 1 1 5B722CA9 +P 10600 3450 +F 0 "SW6" H 10600 3600 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 3400 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 3450 50 0001 C CNN +F 3 "" H 10600 3450 50 0000 C CNN + 1 10600 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D6 +U 1 1 5B722FE1 +P 10900 3600 +F 0 "D6" V 10946 3521 50 0000 R CNN +F 1 "D" V 10855 3521 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10900 3600 50 0001 C CNN +F 3 "" H 10900 3600 50 0001 C CNN + 1 10900 3600 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW8 +U 1 1 5B723388 +P 7400 4100 +F 0 "SW8" H 7400 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 4100 50 0001 C CNN +F 3 "" H 7400 4100 50 0000 C CNN + 1 7400 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW9 +U 1 1 5B723731 +P 8200 4100 +F 0 "SW9" H 8200 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 4100 50 0001 C CNN +F 3 "" H 8200 4100 50 0000 C CNN + 1 8200 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW10 +U 1 1 5B7237A6 +P 9000 4100 +F 0 "SW10" H 9000 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 4100 50 0001 C CNN +F 3 "" H 9000 4100 50 0000 C CNN + 1 9000 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW11 +U 1 1 5B72387D +P 9800 4100 +F 0 "SW11" H 9800 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 4100 50 0001 C CNN +F 3 "" H 9800 4100 50 0000 C CNN + 1 9800 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW12 +U 1 1 5B723AD3 +P 10600 4100 +F 0 "SW12" H 10600 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 4100 50 0001 C CNN +F 3 "" H 10600 4100 50 0000 C CNN + 1 10600 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW7 +U 1 1 5B723C9D +P 6600 4100 +F 0 "SW7" H 6600 4250 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 4000 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 4100 50 0001 C CNN +F 3 "" H 6600 4100 50 0000 C CNN + 1 6600 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D7 +U 1 1 5B723D94 +P 6900 4250 +F 0 "D7" V 6946 4171 50 0000 R CNN +F 1 "D" V 6855 4171 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 6900 4250 50 0001 C CNN +F 3 "" H 6900 4250 50 0001 C CNN + 1 6900 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D8 +U 1 1 5B723E5F +P 7700 4250 +F 0 "D8" V 7746 4171 50 0000 R CNN +F 1 "D" V 7655 4171 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 7700 4250 50 0001 C CNN +F 3 "" H 7700 4250 50 0001 C CNN + 1 7700 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D9 +U 1 1 5B723FA1 +P 8500 4250 +F 0 "D9" V 8546 4171 50 0000 R CNN +F 1 "D" V 8455 4171 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 8500 4250 50 0001 C CNN +F 3 "" H 8500 4250 50 0001 C CNN + 1 8500 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D10 +U 1 1 5B7240EA +P 9300 4250 +F 0 "D10" V 9346 4171 50 0000 R CNN +F 1 "D" V 9255 4171 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 9300 4250 50 0001 C CNN +F 3 "" H 9300 4250 50 0001 C CNN + 1 9300 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D11 +U 1 1 5B72424D +P 10100 4250 +F 0 "D11" V 10146 4171 50 0000 R CNN +F 1 "D" V 10055 4171 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10100 4250 50 0001 C CNN +F 3 "" H 10100 4250 50 0001 C CNN + 1 10100 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D12 +U 1 1 5B7243C0 +P 10900 4250 +F 0 "D12" V 10946 4171 50 0000 R CNN +F 1 "D" V 10855 4171 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10900 4250 50 0001 C CNN +F 3 "" H 10900 4250 50 0001 C CNN + 1 10900 4250 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW13 +U 1 1 5B7250AD +P 6600 4750 +F 0 "SW13" H 6600 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 4750 50 0001 C CNN +F 3 "" H 6600 4750 50 0000 C CNN + 1 6600 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW14 +U 1 1 5B725133 +P 7400 4750 +F 0 "SW14" H 7400 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 4750 50 0001 C CNN +F 3 "" H 7400 4750 50 0000 C CNN + 1 7400 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW15 +U 1 1 5B7251BF +P 8200 4750 +F 0 "SW15" H 8200 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 4750 50 0001 C CNN +F 3 "" H 8200 4750 50 0000 C CNN + 1 8200 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW16 +U 1 1 5B72524E +P 9000 4750 +F 0 "SW16" H 9000 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 4750 50 0001 C CNN +F 3 "" H 9000 4750 50 0000 C CNN + 1 9000 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW17 +U 1 1 5B7252F1 +P 9800 4750 +F 0 "SW17" H 9800 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 4750 50 0001 C CNN +F 3 "" H 9800 4750 50 0000 C CNN + 1 9800 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW18 +U 1 1 5B725398 +P 10600 4750 +F 0 "SW18" H 10600 4900 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 4650 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 4750 50 0001 C CNN +F 3 "" H 10600 4750 50 0000 C CNN + 1 10600 4750 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D13 +U 1 1 5B7254EE +P 6900 4900 +F 0 "D13" V 6946 4821 50 0000 R CNN +F 1 "D" V 6855 4821 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 6900 4900 50 0001 C CNN +F 3 "" H 6900 4900 50 0001 C CNN + 1 6900 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D14 +U 1 1 5B7255FF +P 7700 4900 +F 0 "D14" V 7746 4821 50 0000 R CNN +F 1 "D" V 7655 4821 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 7700 4900 50 0001 C CNN +F 3 "" H 7700 4900 50 0001 C CNN + 1 7700 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D15 +U 1 1 5B72571C +P 8500 4900 +F 0 "D15" V 8546 4821 50 0000 R CNN +F 1 "D" V 8455 4821 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 8500 4900 50 0001 C CNN +F 3 "" H 8500 4900 50 0001 C CNN + 1 8500 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D16 +U 1 1 5B725841 +P 9300 4900 +F 0 "D16" V 9346 4821 50 0000 R CNN +F 1 "D" V 9255 4821 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 9300 4900 50 0001 C CNN +F 3 "" H 9300 4900 50 0001 C CNN + 1 9300 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D17 +U 1 1 5B72596D +P 10100 4900 +F 0 "D17" V 10146 4821 50 0000 R CNN +F 1 "D" V 10055 4821 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10100 4900 50 0001 C CNN +F 3 "" H 10100 4900 50 0001 C CNN + 1 10100 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D18 +U 1 1 5B725AA2 +P 10900 4900 +F 0 "D18" V 10946 4821 50 0000 R CNN +F 1 "D" V 10855 4821 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10900 4900 50 0001 C CNN +F 3 "" H 10900 4900 50 0001 C CNN + 1 10900 4900 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW21 +U 1 1 5B726F89 +P 8200 5400 +F 0 "SW21" H 8200 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 5400 50 0001 C CNN +F 3 "" H 8200 5400 50 0000 C CNN + 1 8200 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW22 +U 1 1 5B727035 +P 9000 5400 +F 0 "SW22" H 9000 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 5400 50 0001 C CNN +F 3 "" H 9000 5400 50 0000 C CNN + 1 9000 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW23 +U 1 1 5B7270F6 +P 9800 5400 +F 0 "SW23" H 9800 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 5400 50 0001 C CNN +F 3 "" H 9800 5400 50 0000 C CNN + 1 9800 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW24 +U 1 1 5B7271A5 +P 10600 5400 +F 0 "SW24" H 10600 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 5400 50 0001 C CNN +F 3 "" H 10600 5400 50 0000 C CNN + 1 10600 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW20 +U 1 1 5B727256 +P 7400 5400 +F 0 "SW20" H 7400 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7400 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7400 5400 50 0001 C CNN +F 3 "" H 7400 5400 50 0000 C CNN + 1 7400 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW19 +U 1 1 5B727312 +P 6600 5400 +F 0 "SW19" H 6600 5550 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 6600 5300 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 6600 5400 50 0001 C CNN +F 3 "" H 6600 5400 50 0000 C CNN + 1 6600 5400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D19 +U 1 1 5B72767A +P 6900 5550 +F 0 "D19" V 6946 5471 50 0000 R CNN +F 1 "D" V 6855 5471 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 6900 5550 50 0001 C CNN +F 3 "" H 6900 5550 50 0001 C CNN + 1 6900 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D20 +U 1 1 5B7277CE +P 7700 5550 +F 0 "D20" V 7746 5471 50 0000 R CNN +F 1 "D" V 7655 5471 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 7700 5550 50 0001 C CNN +F 3 "" H 7700 5550 50 0001 C CNN + 1 7700 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D21 +U 1 1 5B727929 +P 8500 5550 +F 0 "D21" V 8546 5471 50 0000 R CNN +F 1 "D" V 8455 5471 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 8500 5550 50 0001 C CNN +F 3 "" H 8500 5550 50 0001 C CNN + 1 8500 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D22 +U 1 1 5B727A89 +P 9300 5550 +F 0 "D22" V 9346 5471 50 0000 R CNN +F 1 "D" V 9255 5471 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 9300 5550 50 0001 C CNN +F 3 "" H 9300 5550 50 0001 C CNN + 1 9300 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D23 +U 1 1 5B727BFE +P 10100 5550 +F 0 "D23" V 10146 5471 50 0000 R CNN +F 1 "D" V 10055 5471 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10100 5550 50 0001 C CNN +F 3 "" H 10100 5550 50 0001 C CNN + 1 10100 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D24 +U 1 1 5B727D79 +P 10900 5550 +F 0 "D24" V 10946 5471 50 0000 R CNN +F 1 "D" V 10855 5471 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10900 5550 50 0001 C CNN +F 3 "" H 10900 5550 50 0001 C CNN + 1 10900 5550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW27 +U 1 1 5B7293B0 +P 8200 6050 +F 0 "SW27" H 8200 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8200 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8200 6050 50 0001 C CNN +F 3 "" H 8200 6050 50 0000 C CNN + 1 8200 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW28 +U 1 1 5B734347 +P 9000 6050 +F 0 "SW28" H 9000 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 6050 50 0001 C CNN +F 3 "" H 9000 6050 50 0000 C CNN + 1 9000 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW29 +U 1 1 5B73449B +P 9800 6050 +F 0 "SW29" H 9800 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9800 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9800 6050 50 0001 C CNN +F 3 "" H 9800 6050 50 0000 C CNN + 1 9800 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D25 +U 1 1 5B734844 +P 6900 6200 +F 0 "D25" V 6946 6121 50 0000 R CNN +F 1 "D" V 6855 6121 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 6900 6200 50 0001 C CNN +F 3 "" H 6900 6200 50 0001 C CNN + 1 6900 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D26 +U 1 1 5B7349D1 +P 7700 6200 +F 0 "D26" V 7746 6121 50 0000 R CNN +F 1 "D" V 7655 6121 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 7700 6200 50 0001 C CNN +F 3 "" H 7700 6200 50 0001 C CNN + 1 7700 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D27 +U 1 1 5B734B62 +P 8500 6200 +F 0 "D27" V 8546 6121 50 0000 R CNN +F 1 "D" V 8455 6121 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 8500 6200 50 0001 C CNN +F 3 "" H 8500 6200 50 0001 C CNN + 1 8500 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D28 +U 1 1 5B734CF9 +P 9300 6200 +F 0 "D28" V 9346 6121 50 0000 R CNN +F 1 "D" V 9255 6121 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 9300 6200 50 0001 C CNN +F 3 "" H 9300 6200 50 0001 C CNN + 1 9300 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D29 +U 1 1 5B734F9E +P 10100 6200 +F 0 "D29" V 10146 6121 50 0000 R CNN +F 1 "D" V 10055 6121 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10100 6200 50 0001 C CNN +F 3 "" H 10100 6200 50 0001 C CNN + 1 10100 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR04 +U 1 1 5B736B57 +P 2700 1150 +F 0 "#PWR04" H 2700 1000 50 0001 C CNN +F 1 "VCC" H 2700 1300 50 0000 C CNN +F 2 "" H 2700 1150 50 0001 C CNN +F 3 "" H 2700 1150 50 0001 C CNN + 1 2700 1150 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR05 +U 1 1 5B739B47 +P 2850 3650 +F 0 "#PWR05" H 2850 3500 50 0001 C CNN +F 1 "VCC" H 2850 3800 50 0000 C CNN +F 2 "" H 2850 3650 50 0001 C CNN +F 3 "" H 2850 3650 50 0001 C CNN + 1 2850 3650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR06 +U 1 1 5B739CDC +P 3000 3650 +F 0 "#PWR06" H 3000 3500 50 0001 C CNN +F 1 "VCC" H 3000 3800 50 0000 C CNN +F 2 "" H 3000 3650 50 0001 C CNN +F 3 "" H 3000 3650 50 0001 C CNN + 1 3000 3650 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:R-Lily58-cache-Lily58_Pro-rescue R1 +U 1 1 5B739F4A +P 2850 3800 +F 0 "R1" V 2950 3800 50 0000 C BNN +F 1 "R" V 2850 3800 50 0000 C CNN +F 2 "SofleKeyboard-footprint:RESISTOR_mini" V 2780 3800 50 0001 C CNN +F 3 "" H 2850 3800 50 0001 C CNN + 1 2850 3800 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:R-Lily58-cache-Lily58_Pro-rescue R2 +U 1 1 5B73A034 +P 3000 3800 +F 0 "R2" V 3100 3800 50 0000 C BNN +F 1 "R" V 3000 3800 50 0000 C CNN +F 2 "SofleKeyboard-footprint:RESISTOR_mini" V 2930 3800 50 0001 C CNN +F 3 "" H 3000 3800 50 0001 C CNN + 1 3000 3800 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:MJ-4PP-9-Lily58-cache-Lily58_Pro-rescue J2 +U 1 1 5B742D8C +P 1150 3200 +F 0 "J2" H 1100 3500 60 0000 C CNN +F 1 "4PIN" H 1100 2900 60 0000 C CNN +F 2 "SofleKeyboard-footprint:MJ-4PP-9" H 1150 3150 60 0001 C CNN +F 3 "" H 1150 3150 60 0000 C CNN + 1 1150 3200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:LED-Lily58-cache-Lily58_Pro-rescue J1 +U 1 1 5B74AE32 +P 2550 2300 +F 0 "J1" H 2550 2500 50 0000 C CNN +F 1 "LED" H 2550 2100 50 0000 C CNN +F 2 "SofleKeyboard-footprint:LED" H 2550 2300 50 0001 C CNN +F 3 "" H 2550 2300 50 0001 C CNN + 1 2550 2300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR07 +U 1 1 5B74B06A +P 2750 2200 +F 0 "#PWR07" H 2750 2050 50 0001 C CNN +F 1 "VCC" H 2767 2373 50 0000 C CNN +F 2 "" H 2750 2200 50 0001 C CNN +F 3 "" H 2750 2200 50 0001 C CNN + 1 2750 2200 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR08 +U 1 1 5B74B15A +P 2750 2400 +F 0 "#PWR08" H 2750 2150 50 0001 C CNN +F 1 "GND" H 2755 2227 50 0000 C CNN +F 2 "" H 2750 2400 50 0001 C CNN +F 3 "" H 2750 2400 50 0001 C CNN + 1 2750 2400 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR010 +U 1 1 5B74C10F +P 900 2450 +F 0 "#PWR010" H 900 2200 50 0001 C CNN +F 1 "GND" H 905 2277 50 0000 C CNN +F 2 "" H 900 2450 50 0001 C CNN +F 3 "" H 900 2450 50 0001 C CNN + 1 900 2450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:PWR_FLAG-Lily58-cache-Lily58_Pro-rescue #FLG01 +U 1 1 5B74C681 +P 3550 7500 +F 0 "#FLG01" H 3550 7575 50 0001 C CNN +F 1 "PWR_FLAG" H 3550 7674 50 0000 C CNN +F 2 "" H 3550 7500 50 0001 C CNN +F 3 "" H 3550 7500 50 0001 C CNN + 1 3550 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR012 +U 1 1 5B74C7EB +P 3550 7500 +F 0 "#PWR012" H 3550 7250 50 0001 C CNN +F 1 "GND" H 3555 7327 50 0000 C CNN +F 2 "" H 3550 7500 50 0001 C CNN +F 3 "" H 3550 7500 50 0001 C CNN + 1 3550 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-Lily58-cache-Lily58_Pro-rescue #PWR013 +U 1 1 5B74C8DE +P 3900 7500 +F 0 "#PWR013" H 3900 7350 50 0001 C CNN +F 1 "VCC" H 3917 7673 50 0000 C CNN +F 2 "" H 3900 7500 50 0001 C CNN +F 3 "" H 3900 7500 50 0001 C CNN + 1 3900 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:PWR_FLAG-Lily58-cache-Lily58_Pro-rescue #FLG02 +U 1 1 5B74C9D1 +P 3900 7500 +F 0 "#FLG02" H 3900 7575 50 0001 C CNN +F 1 "PWR_FLAG" H 3900 7673 50 0000 C CNN +F 2 "" H 3900 7500 50 0001 C CNN +F 3 "" H 3900 7500 50 0001 C CNN + 1 3900 7500 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH1 +U 1 1 5B74CE27 +P 750 7500 +F 0 "TH1" H 750 7500 60 0000 C CNN +F 1 "HOLE" H 750 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:M2_HOLE_PCB" H 750 7500 60 0001 C CNN +F 3 "" H 750 7500 60 0000 C CNN + 1 750 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH2 +U 1 1 5B74D0C7 +P 1100 7500 +F 0 "TH2" H 1100 7500 60 0000 C CNN +F 1 "HOLE" H 1100 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:M2_HOLE_PCB" H 1100 7500 60 0001 C CNN +F 3 "" H 1100 7500 60 0000 C CNN + 1 1100 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH4 +U 1 1 5B74D1C0 +P 2100 7500 +F 0 "TH4" H 2100 7500 60 0000 C CNN +F 1 "HOLE" H 2100 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:HOLE_M2_TH" H 2100 7500 60 0001 C CNN +F 3 "" H 2100 7500 60 0000 C CNN + 1 2100 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH5 +U 1 1 5B74D78B +P 2450 7500 +F 0 "TH5" H 2450 7500 60 0000 C CNN +F 1 "HOLE" H 2450 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:HOLE_M2_TH" H 2450 7500 60 0001 C CNN +F 3 "" H 2450 7500 60 0000 C CNN + 1 2450 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH6 +U 1 1 5B74D88C +P 2800 7500 +F 0 "TH6" H 2800 7500 60 0000 C CNN +F 1 "HOLE" H 2800 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:HOLE_M2_TH" H 2800 7500 60 0001 C CNN +F 3 "" H 2800 7500 60 0000 C CNN + 1 2800 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH7 +U 1 1 5B74D98F +P 3150 7500 +F 0 "TH7" H 3150 7500 60 0000 C CNN +F 1 "HOLE" H 3150 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:HOLE_M2_TH" H 3150 7500 60 0001 C CNN +F 3 "" H 3150 7500 60 0000 C CNN + 1 3150 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:HOLE-Lily58-cache-Lily58_Pro-rescue TH3 +U 1 1 5B74DA95 +P 1750 7500 +F 0 "TH3" H 1750 7500 60 0000 C CNN +F 1 "HOLE" H 1750 7400 60 0000 C CNN +F 2 "SofleKeyboard-footprint:HOLE_M2_TH" H 1750 7500 60 0001 C CNN +F 3 "" H 1750 7500 60 0000 C CNN + 1 1750 7500 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:SW_RST-Lily58-cache-Lily58_Pro-rescue RSW1 +U 1 1 5B8CE7E7 +P 1050 2450 +F 0 "RSW1" H 1050 2706 40 0000 C CNN +F 1 "SW_RST" H 1050 2623 50 0000 C CNN +F 2 "SofleKeyboard-footprint:TACT_SWITCH_TVBP06" H 1050 2450 50 0001 C CNN +F 3 "" H 1050 2450 50 0001 C CNN + 1 1050 2450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR0101 +U 1 1 5B8CD05E +P 2700 950 +F 0 "#PWR0101" H 2700 700 50 0001 C CNN +F 1 "GND" H 2700 800 50 0000 C CNN +F 2 "" H 2700 950 50 0001 C CNN +F 3 "" H 2700 950 50 0001 C CNN + 1 2700 950 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-Lily58-cache-Lily58_Pro-rescue #PWR0102 +U 1 1 5B8CD27F +P 850 1150 +F 0 "#PWR0102" H 850 900 50 0001 C CNN +F 1 "GND" H 850 1000 50 0000 C CNN +F 2 "" H 850 1150 50 0001 C CNN +F 3 "" H 850 1150 50 0001 C CNN + 1 850 1150 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR02 +U 1 1 5B8F3218 +P 1700 3450 +F 0 "#PWR02" H 1700 3200 50 0001 C CNN +F 1 "GND" H 1705 3277 50 0000 C CNN +F 2 "" H 1700 3450 50 0001 C CNN +F 3 "" H 1700 3450 50 0001 C CNN + 1 1700 3450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-power #PWR01 +U 1 1 5B8F42DA +P 1700 3000 +F 0 "#PWR01" H 1700 2850 50 0001 C CNN +F 1 "VCC" H 1717 3173 50 0000 C CNN +F 2 "" H 1700 3000 50 0001 C CNN +F 3 "" H 1700 3000 50 0001 C CNN + 1 1700 3000 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:i2c_pin-Lily58-cache-Lily58_Pro-rescue P1 +U 1 1 5B8F6780 +P 2000 2850 +F 0 "P1" H 2000 2950 50 0000 C CNN +F 1 "i2c_pin" V 2100 2850 50 0000 C CNN +F 2 "SofleKeyboard-footprint:1pin_conn" H 2000 2850 50 0001 C CNN +F 3 "" H 2000 2850 50 0001 C CNN + 1 2000 2850 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:i2c_pin-Lily58-cache-Lily58_Pro-rescue P2 +U 1 1 5B8F6980 +P 2000 3600 +F 0 "P2" H 2000 3500 50 0000 C CNN +F 1 "i2c_pin" V 2100 3600 50 0000 C CNN +F 2 "SofleKeyboard-footprint:1pin_conn" H 2000 3600 50 0001 C CNN +F 3 "" H 2000 3600 50 0001 C CNN + 1 2000 3600 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper-Device W1 +U 1 1 5B900157 +P 2300 3400 +F 0 "W1" H 2300 3350 50 0000 C CNN +F 1 "jumper" H 2300 3550 50 0000 C CNN +F 2 "SofleKeyboard-footprint:jumper_data" H 2300 3400 50 0001 C CNN +F 3 "" H 2300 3400 50 0000 C CNN + 1 2300 3400 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard-rescue:OLED-Lily58-cache-Lily58_Pro-rescue J3 +U 1 1 5B91007B +P 800 3950 +F 0 "J3" H 800 3700 50 0000 C CNN +F 1 "OLED" H 800 4200 50 0000 C CNN +F 2 "SofleKeyboard-footprint:OLED_4Pin" H 800 3950 50 0001 C CNN +F 3 "" H 800 3950 50 0000 C CNN + 1 800 3950 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP1 +U 1 1 5B911E74 +P 1300 3800 +F 0 "JP1" H 1300 3750 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 3894 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 3800 50 0001 C CNN +F 3 "~" H 1300 3800 50 0001 C CNN + 1 1300 3800 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP2 +U 1 1 5B9120CE +P 1300 3900 +F 0 "JP2" H 1300 3850 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 3994 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 3900 50 0001 C CNN +F 3 "~" H 1300 3900 50 0001 C CNN + 1 1300 3900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP3 +U 1 1 5B913646 +P 1300 4000 +F 0 "JP3" H 1300 3950 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4094 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 4000 50 0001 C CNN +F 3 "~" H 1300 4000 50 0001 C CNN + 1 1300 4000 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP4 +U 1 1 5B913C11 +P 1300 4100 +F 0 "JP4" H 1300 4050 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4194 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 4100 50 0001 C CNN +F 3 "~" H 1300 4100 50 0001 C CNN + 1 1300 4100 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP5 +U 1 1 5B9141F4 +P 1300 4250 +F 0 "JP5" H 1300 4200 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4344 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 4250 50 0001 C CNN +F 3 "~" H 1300 4250 50 0001 C CNN + 1 1300 4250 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP6 +U 1 1 5B9141FA +P 1300 4350 +F 0 "JP6" H 1300 4300 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4444 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 4350 50 0001 C CNN +F 3 "~" H 1300 4350 50 0001 C CNN + 1 1300 4350 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP7 +U 1 1 5B914200 +P 1300 4450 +F 0 "JP7" H 1300 4400 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4544 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 4450 50 0001 C CNN +F 3 "~" H 1300 4450 50 0001 C CNN + 1 1300 4450 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP8 +U 1 1 5B914206 +P 1300 4550 +F 0 "JP8" H 1300 4500 50 0000 C CNN +F 1 "Jumper_NO_Small" H 1300 4644 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 1300 4550 50 0001 C CNN +F 3 "~" H 1300 4550 50 0001 C CNN + 1 1300 4550 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR03 +U 1 1 5B9205B8 +P 1400 3800 +F 0 "#PWR03" H 1400 3550 50 0001 C CNN +F 1 "GND" V 1405 3672 50 0000 R CNN +F 2 "" H 1400 3800 50 0001 C CNN +F 3 "" H 1400 3800 50 0001 C CNN + 1 1400 3800 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-power #PWR09 +U 1 1 5B9207DA +P 1400 3900 +F 0 "#PWR09" H 1400 3750 50 0001 C CNN +F 1 "VCC" V 1417 4028 50 0000 L CNN +F 2 "" H 1400 3900 50 0001 C CNN +F 3 "" H 1400 3900 50 0001 C CNN + 1 1400 3900 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR014 +U 1 1 5B920A11 +P 1400 4550 +F 0 "#PWR014" H 1400 4300 50 0001 C CNN +F 1 "GND" V 1405 4422 50 0000 R CNN +F 2 "" H 1400 4550 50 0001 C CNN +F 3 "" H 1400 4550 50 0001 C CNN + 1 1400 4550 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:VCC-power #PWR011 +U 1 1 5B920C33 +P 1400 4450 +F 0 "#PWR011" H 1400 4300 50 0001 C CNN +F 1 "VCC" V 1417 4578 50 0000 L CNN +F 2 "" H 1400 4450 50 0001 C CNN +F 3 "" H 1400 4450 50 0001 C CNN + 1 1400 4450 + 0 1 1 0 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW30 +U 1 1 5D954F78 +P 10600 6050 +F 0 "SW30" H 10600 6200 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10600 5950 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10600 6050 50 0001 C CNN +F 3 "" H 10600 6050 50 0000 C CNN + 1 10600 6050 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:D-Lily58-cache-Lily58_Pro-rescue D30 +U 1 1 5D956FE1 +P 10900 6200 +F 0 "D30" V 10946 6121 50 0000 R CNN +F 1 "D" V 10855 6121 50 0000 R CNN +F 2 "Diode_SMD:crkbd-diode" H 10900 6200 50 0001 C CNN +F 3 "" H 10900 6200 50 0001 C CNN + 1 10900 6200 + 0 -1 -1 0 +$EndComp +$Comp +L SofleKeyboard-rescue:Rotary_Encoder_Switch-Device SW25 +U 1 1 5DA04574 +P 2550 6150 +F 0 "SW25" H 2550 6517 50 0000 C CNN +F 1 "Rotary_Encoder_Switch" H 2550 6426 50 0000 C CNN +F 2 "SofleKeyboard-footprint:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified" H 2400 6310 50 0001 C CNN +F 3 "~" H 2550 6410 50 0001 C CNN + 1 2550 6150 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard-rescue:GND-power #PWR0103 +U 1 1 5DA35FE6 +P 1650 6250 +F 0 "#PWR0103" H 1650 6000 50 0001 C CNN +F 1 "GND" H 1655 6077 50 0000 C CNN +F 2 "" H 1650 6250 50 0001 C CNN +F 3 "" H 1650 6250 50 0001 C CNN + 1 1650 6250 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW5 +U 2 1 5F751B72 +P 10150 850 +F 0 "SW5" H 10150 677 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 1100 50 0001 C CNN +F 3 "" H 10150 1100 50 0001 C CNN + 2 10150 850 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW6 +U 2 1 5F752AB9 +P 10750 850 +F 0 "SW6" H 10750 1023 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 1100 50 0001 C CNN +F 3 "" H 10750 1100 50 0001 C CNN + 2 10750 850 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW7 +U 2 1 5F754917 +P 7750 1300 +F 0 "SW7" H 7750 1127 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 1550 50 0001 C CNN +F 3 "" H 7750 1550 50 0001 C CNN + 2 7750 1300 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW8 +U 2 1 5F755BEC +P 8350 1300 +F 0 "SW8" H 8350 1473 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8350 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8350 1550 50 0001 C CNN +F 3 "" H 8350 1550 50 0001 C CNN + 2 8350 1300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW9 +U 2 1 5F756CE6 +P 8950 1300 +F 0 "SW9" H 8950 1127 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 8950 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 8950 1550 50 0001 C CNN +F 3 "" H 8950 1550 50 0001 C CNN + 2 8950 1300 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW10 +U 2 1 5F757ED7 +P 9550 1300 +F 0 "SW10" H 9550 1473 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9550 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9550 1550 50 0001 C CNN +F 3 "" H 9550 1550 50 0001 C CNN + 2 9550 1300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW11 +U 2 1 5F758F15 +P 10150 1300 +F 0 "SW11" H 10150 1127 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10150 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10150 1550 50 0001 C CNN +F 3 "" H 10150 1550 50 0001 C CNN + 2 10150 1300 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW12 +U 2 1 5F75A082 +P 10750 1300 +F 0 "SW12" H 10750 1473 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 10750 1574 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 10750 1550 50 0001 C CNN +F 3 "" H 10750 1550 50 0001 C CNN + 2 10750 1300 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D35 +U 1 1 5F7EF5F2 +P 4500 1550 +F 0 "D35" H 4500 1377 50 0000 C CNN +F 1 "LED_sk2812_SM" H 4500 1724 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 4500 1550 50 0001 C CNN +F 3 "" H 4500 1550 50 0001 C CNN + 1 4500 1550 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D34 +U 1 1 5F7EC8B3 +P 3750 1550 +F 0 "D34" H 3750 1377 50 0000 C CNN +F 1 "LED_sk2812_SM" H 3750 1724 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 3750 1550 50 0001 C CNN +F 3 "" H 3750 1550 50 0001 C CNN + 1 3750 1550 + -1 0 0 1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D33 +U 1 1 5F7EC8AD +P 5300 900 +F 0 "D33" H 5300 1073 50 0000 C CNN +F 1 "LED_sk2812_SM" H 5300 1074 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 5300 900 50 0001 C CNN +F 3 "" H 5300 900 50 0001 C CNN + 1 5300 900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D32 +U 1 1 5F7E9258 +P 4500 900 +F 0 "D32" H 4500 1073 50 0000 C CNN +F 1 "LED_sk2812_SM" H 4500 1074 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 4500 900 50 0001 C CNN +F 3 "" H 4500 900 50 0001 C CNN + 1 4500 900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:LED_sk2812_SM D31 +U 1 1 5F7E6561 +P 3750 900 +F 0 "D31" H 3750 1073 50 0000 C CNN +F 1 "LED_sk2812_SM" H 3750 1074 50 0001 C CNN +F 2 "LED_SMD:SK6812MINI_underglow_dev_Silk_GND" H 3750 900 50 0001 C CNN +F 3 "" H 3750 900 50 0001 C CNN + 1 3750 900 + 1 0 0 -1 +$EndComp +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW1 +U 2 1 5F749FCB +P 7750 850 +F 0 "SW1" H 7750 677 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 7750 1124 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 7750 1100 50 0001 C CNN +F 3 "" H 7750 1100 50 0001 C CNN + 2 7750 850 + -1 0 0 1 +$EndComp +NoConn ~ 7950 2250 +$Comp +L SofleKeyboard:SW_PUSH-MX_W_LED SW4 +U 1 1 5B722A11 +P 9000 3450 +F 0 "SW4" H 9000 3705 50 0000 C CNN +F 1 "SW_PUSH-MX_W_LED" H 9000 3614 50 0001 C CNN +F 2 "Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND" H 9000 3450 50 0001 C CNN +F 3 "" H 9000 3450 50 0000 C CNN + 1 9000 3450 + 1 0 0 -1 +$EndComp +Wire Wire Line + 4100 2900 4300 2900 +Wire Wire Line + 4300 2650 4300 2900 +Wire Wire Line + 4850 2550 5400 2550 +Wire Wire Line + 5400 2550 5400 2850 +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP9 +U 1 1 61D5D1D0 +P 4050 2550 +F 0 "JP9" H 4050 2500 50 0000 C CNN +F 1 "Jumper_NO_Small" H 4050 2644 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 4050 2550 50 0001 C CNN +F 3 "~" H 4050 2550 50 0001 C CNN + 1 4050 2550 + 1 0 0 -1 +$EndComp +Connection ~ 4200 2550 +Wire Wire Line + 4200 2550 4150 2550 +$Comp +L SofleKeyboard-rescue:Jumper_NO_Small-Device JP10 +U 1 1 620925F6 +P 6450 700 +F 0 "JP10" H 6450 650 50 0000 C CNN +F 1 "Jumper_NO_Small" H 6450 794 50 0001 C CNN +F 2 "SofleKeyboard-footprint:Jumper" H 6450 700 50 0001 C CNN +F 3 "~" H 6450 700 50 0001 C CNN + 1 6450 700 + 1 0 0 -1 +$EndComp +Wire Wire Line + 5500 1600 7100 1600 +Text GLabel 10950 3000 0 50 Input ~ 0 +BL +Text GLabel 6950 700 1 50 Input ~ 0 +BL +$EndSCHEMATC diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/1pin_conn.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/1pin_conn.kicad_mod new file mode 100644 index 00000000..a92a3830 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/1pin_conn.kicad_mod @@ -0,0 +1,33 @@ +(module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) + (descr "Resitance 3 pas") + (tags R) + (autoplace_cost180 10) + (fp_text reference P1 (at 0 -1.671944) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value i2c_pin (at 0 -1.4605) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text user P1 (at 0.2 -1.7) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (pad 1 thru_hole circle (at 0 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/3x1header.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/3x1header.kicad_mod new file mode 100644 index 00000000..8e4de9e9 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/3x1header.kicad_mod @@ -0,0 +1,35 @@ +(module Connector:3x1header (layer F.Cu) (tedit 5F6F4566) + (fp_text reference J4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value "key leds" (at 0 7.62) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) + (pad 1 thru_hole rect (at 0 0 90) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask)) + (pad 2 thru_hole circle (at 0 2.5) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask)) + (pad 3 thru_hole circle (at 0 5.1) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/HOLE_M2_TH.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/HOLE_M2_TH.kicad_mod new file mode 100644 index 00000000..4e35e5f7 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/HOLE_M2_TH.kicad_mod @@ -0,0 +1,10 @@ +(module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805C11) + (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + ) + (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/Jumper.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/Jumper.kicad_mod new file mode 100644 index 00000000..fad2ae19 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/Jumper.kicad_mod @@ -0,0 +1,22 @@ +(module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) + (attr smd) + (fp_text reference JP1 (at -2.286 0.127) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -0.50038 0) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/LED.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/LED.kicad_mod new file mode 100644 index 00000000..e9bbf3a9 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/LED.kicad_mod @@ -0,0 +1,53 @@ +(module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5D8F83FF) + (fp_text reference J1 (at 0 -2.54 -180) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED (at 0 7.62 -180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user VCC (at -2.2 0.1 -180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user VCC (at -2.2 0.1 -180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user GND (at -2.1 5.1 -180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user LED (at -2.2 2.5 -180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user LED (at -2.2 2.5 -180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user GND (at -2.1 5.14 -180) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) + (pad 3 thru_hole rect (at 0 5.1) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask)) + (pad 2 thru_hole rect (at 0 2.5) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask)) + (pad 1 thru_hole rect (at 0 0 90) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/M2_HOLE_PCB.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/M2_HOLE_PCB.kicad_mod new file mode 100644 index 00000000..875c6a78 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/M2_HOLE_PCB.kicad_mod @@ -0,0 +1,9 @@ +(module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) + (fp_text reference TH1 (at 0 2.7) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/MJ-4PP-9.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/MJ-4PP-9.kicad_mod new file mode 100644 index 00000000..3faad7c5 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/MJ-4PP-9.kicad_mod @@ -0,0 +1,43 @@ +(module SofleKeyboard-footprint:MJ-4PP-9 (layer F.Cu) (tedit 5D8BAE3B) + (fp_text reference J2 (at -0.889 6.4135) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value 4PIN (at 0 14) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user TRRS (at -0.75 6.45) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user TRRS (at -0.75 6.45) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) + (pad 4 thru_hole oval (at -2.1 11.8) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (clearance 0.15)) + (pad 1 thru_hole oval (at 2.1 10.3) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (clearance 0.15)) + (pad 2 thru_hole oval (at 2.1 6.3) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS)) + (pad 3 thru_hole oval (at 2.1 3.3) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at 0 8.5) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at 0 1.5) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad 2 thru_hole oval (at -3.85 6.3) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS)) + (pad 3 thru_hole oval (at -3.85 3.3) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS)) + (pad 4 thru_hole oval (at 0.35 11.8) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (clearance 0.15)) + (pad 1 thru_hole oval (at -3.85 10.3) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (clearance 0.15)) + (pad "" np_thru_hole circle (at -1.75 1.5) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at -1.75 8.5) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (model "../../../../../../Users/pluis/Documents/Magic Briefcase/Documents/KiCad/3d/AB2_TRS_3p5MM_PTH.wrl" + (at (xyz 0 0 0)) + (scale (xyz 0.42 0.42 0.42)) + (rotate (xyz 0 0 90)) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/OLED_4Pin.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/OLED_4Pin.kicad_mod new file mode 100644 index 00000000..42685646 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/OLED_4Pin.kicad_mod @@ -0,0 +1,22 @@ +(module SofleKeyboard-footprint:OLED_4Pin (layer F.Cu) (tedit 59FC8837) + (descr "Connecteur 6 pins") + (tags "CONN DEV") + (fp_text reference J3 (at -1.915 1.93 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value OLED (at 3.81 1.27) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer B.SilkS) (width 0.15)) + (pad 1 thru_hole circle (at 0 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 3 thru_hole circle (at 5.08 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 4 thru_hole circle (at 7.62 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/ProMicro.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/ProMicro.kicad_mod new file mode 100644 index 00000000..c445154f --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/ProMicro.kicad_mod @@ -0,0 +1,78 @@ +(module SofleKeyboard-footprint:ProMicro (layer F.Cu) (tedit 5B8BDEB4) + (fp_text reference U1 (at 0 1.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value ProMicro (at 0 -0.8) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -16.04) (layer B.SilkS) (width 0.15)) + (pad 24 thru_hole circle (at 6.42 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 23 thru_hole circle (at 6.42 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 22 thru_hole circle (at 6.42 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 21 thru_hole circle (at 6.42 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 20 thru_hole circle (at 6.42 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 19 thru_hole circle (at 6.42 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 18 thru_hole circle (at 6.42 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 17 thru_hole circle (at 6.42 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 16 thru_hole circle (at 6.42 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 15 thru_hole circle (at 6.42 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 14 thru_hole circle (at 6.42 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 13 thru_hole circle (at 6.42 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 12 thru_hole circle (at -8.82 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 11 thru_hole circle (at -8.82 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 10 thru_hole circle (at -8.82 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 9 thru_hole circle (at -8.82 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 8 thru_hole circle (at -8.82 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 7 thru_hole circle (at -8.82 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 6 thru_hole circle (at -8.82 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 5 thru_hole circle (at -8.82 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 4 thru_hole circle (at -8.82 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 3 thru_hole circle (at -8.82 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 2 thru_hole circle (at -8.82 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 1 thru_hole circle (at -8.82 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 5 thru_hole circle (at 7.718815 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 7 thru_hole circle (at 7.718815 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 24 thru_hole circle (at -7.521185 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 2 thru_hole circle (at 7.718815 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 11 thru_hole circle (at 7.718815 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 13 thru_hole circle (at -7.521185 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 8 thru_hole circle (at 7.718815 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 9 thru_hole circle (at 7.718815 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 17 thru_hole circle (at -7.521185 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 15 thru_hole circle (at -7.521185 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 20 thru_hole circle (at -7.521185 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 21 thru_hole circle (at -7.521185 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 23 thru_hole circle (at -7.521185 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 19 thru_hole circle (at -7.521185 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 12 thru_hole circle (at 7.718815 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 16 thru_hole circle (at -7.521185 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 1 thru_hole circle (at 7.718815 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 3 thru_hole circle (at 7.718815 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 14 thru_hole circle (at -7.521185 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 4 thru_hole circle (at 7.718815 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 6 thru_hole circle (at 7.718815 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 18 thru_hole circle (at -7.521185 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 10 thru_hole circle (at 7.718815 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) + (pad 22 thru_hole circle (at -7.521185 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/RESISTOR_mini.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/RESISTOR_mini.kicad_mod new file mode 100644 index 00000000..20b1eeb0 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/RESISTOR_mini.kicad_mod @@ -0,0 +1,34 @@ +(module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) + (descr "Resitance 3 pas") + (tags R) + (autoplace_cost180 10) + (fp_text reference R2 (at -0.039272 0.038035 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text user R2 (at 0 0 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified.kicad_mod new file mode 100644 index 00000000..8dcd8b27 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified.kicad_mod @@ -0,0 +1,56 @@ +(module SofleKeyboard-footprint:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified (layer F.Cu) (tedit 5D5C0C22) + (descr "Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html") + (tags "rotary encoder") + (fp_text reference SW25 (at 4.24 4.6) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value Rotary_Encoder_Switch (at 0 7.9) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -0.5 0) (end 0.5 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) + (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) + (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) + (pad A thru_hole circle (at -7.5 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask)) + (pad C thru_hole circle (at -7.5 0) (size 2 2) (drill 1) (layers *.Cu *.Mask)) + (pad B thru_hole circle (at -7.5 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask)) + (pad MP thru_hole rect (at 0 -5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad MP thru_hole rect (at 0 5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad S2 thru_hole circle (at 7 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask)) + (pad S1 thru_hole circle (at 7 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask)) + (model ${KISYS3DMOD}/Rotary_Encoder.3dshapes/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 1 1 1)) + (rotate (xyz 0 0 0)) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_and_cherry.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_and_cherry.kicad_mod new file mode 100644 index 00000000..e29285e7 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_and_cherry.kicad_mod @@ -0,0 +1,121 @@ +(module Button_Switch_Keyboard:SK6812MINI_and_cherry (layer F.Cu) (tedit 5F75D850) + (fp_text reference SW1 (at 0 3 -180 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 -180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 -180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 -180) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.3706 7.1254) (end -3.4206 7.1254) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.3706 5.6754) (end -1.3706 7.1254) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4206 5.6754) (end -1.3706 5.6754) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4206 7.1254) (end -3.4206 5.6754) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4206 5.35) (end -3.4206 3.9) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.4206 3.9) (end -1.3706 3.9) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.3706 3.9) (end -1.3706 5.35) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.3706 5.35) (end -3.4206 5.35) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (pad 2 smd rect (at -2.4 6.375) (size 1.6 1) (layers B.Cu B.Paste B.Mask)) + (pad 1 smd rect (at -2.4 4.625) (size 1.6 1) (layers B.Cu B.Paste B.Mask)) + (pad 4 smd rect (at 2.4 4.625) (size 1.6 1) (layers B.Cu B.Paste B.Mask)) + (pad 3 smd rect (at 2.4 6.375) (size 1.6 1) (layers B.Cu B.Paste B.Mask)) + (pad 2 smd rect (at -2.4 4.625) (size 1.6 1) (layers F.Cu F.Paste F.Mask)) + (pad 1 smd rect (at -2.4 6.375) (size 1.6 1) (layers F.Cu F.Paste F.Mask)) + (pad 3 smd rect (at 2.4 4.625) (size 1.6 1) (layers F.Cu F.Paste F.Mask)) + (pad 4 smd rect (at 2.4 6.375) (size 1.6 1) (layers F.Cu F.Paste F.Mask)) + (pad "" np_thru_hole circle (at 2.54 -5.08 180) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 90) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 180) (size 2.3 2) (layers B.Cu B.Paste B.Mask)) + (pad "" np_thru_hole circle (at -3.81 -2.54 180) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 180) (size 2.3 2) (layers F.Cu F.Paste F.Mask)) + (pad 6 smd rect (at -5.7 -5.12 180) (size 2.3 2) (layers F.Cu F.Mask)) + (pad "" np_thru_hole circle (at -2.54 -5.08 180) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 180) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 180) (size 2.3 2) (layers B.Cu B.Paste B.Mask)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_underglow_dev.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_underglow_dev.kicad_mod new file mode 100644 index 00000000..1e103714 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/SK6812MINI_underglow_dev.kicad_mod @@ -0,0 +1,28 @@ +(module LED_SMD:SK6812MINI_underglow_dev (layer F.Cu) (tedit 5F6F3B08) + (fp_text reference D31 (at -4.94 -0.76 -180) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value LED_sk2812_SM (at -0.3 2.7 -180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -3.4142 0.15) (end -0.9942 0.15) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.6) (end -3.4142 0.15) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15) (end -0.9642 1.6) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.6) (end -3.4142 1.6) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.4142 -1.6) (end -0.9942 -1.6) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 -0.15) (end -3.4142 -1.6) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 -1.6) (end -0.9642 -0.15) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 -0.15) (end -3.4142 -0.15) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask)) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask)) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/TACT_SWITCH_TVBP06.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/TACT_SWITCH_TVBP06.kicad_mod new file mode 100644 index 00000000..e5c327b8 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/TACT_SWITCH_TVBP06.kicad_mod @@ -0,0 +1,29 @@ +(module SofleKeyboard-footprint:TACT_SWITCH_TVBP06 (layer F.Cu) (tedit 5B8CD44F) + (fp_text reference RSW1 (at 0 -1.7 -180) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_RST (at 0 2 -180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user RESET (at 0 0) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user RESET (at 0 0) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 2.9 -1.8) (layer B.SilkS) (width 0.15)) + (pad 1 thru_hole circle (at -3.25 0) (size 2 2) (drill 1.3) (layers *.Cu *.Mask)) + (pad 2 thru_hole circle (at 3.25 0) (size 2 2) (drill 1.3) (layers *.Cu *.Mask)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/crkbd-diode.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/crkbd-diode.kicad_mod new file mode 100644 index 00000000..8a421eb9 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/crkbd-diode.kicad_mod @@ -0,0 +1,36 @@ +(module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) + (descr "Resitance 3 pas") + (tags R) + (autoplace_cost180 10) + (fp_text reference D1 (at 0.5 0 -180) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 -180) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/gecko-logo.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/gecko-logo.kicad_mod new file mode 100644 index 00000000..9e4fc12a --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/gecko-logo.kicad_mod @@ -0,0 +1,160 @@ +(module dane:gecko-logo (layer F.Cu) (tedit 0) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) +) diff --git a/Sofle_RGB_v3/PCB/SofleRGB.pretty/jumper_data.kicad_mod b/Sofle_RGB_v3/PCB/SofleRGB.pretty/jumper_data.kicad_mod new file mode 100644 index 00000000..83f8ed09 --- /dev/null +++ b/Sofle_RGB_v3/PCB/SofleRGB.pretty/jumper_data.kicad_mod @@ -0,0 +1,23 @@ +(module SofleKeyboard-footprint:jumper_data (layer F.Cu) (tedit 5D87BC97) + (attr smd) + (fp_text reference W1 (at -1.8 0 -270) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value jumper (at 0 1.524 -180) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) + ) +) diff --git a/Sofle_RGB_v3/PCB/custom mods/big gecko.kicad_mod b/Sofle_RGB_v3/PCB/custom mods/big gecko.kicad_mod new file mode 100644 index 00000000..cd47836d --- /dev/null +++ b/Sofle_RGB_v3/PCB/custom mods/big gecko.kicad_mod @@ -0,0 +1,86 @@ +(module LOGO (layer F.Cu) + (at 0 0) + (fp_text reference "G***" (at 0 0) (layer F.SilkS) hide + (effects (font (thickness 0.3))) + ) + (fp_text value "LOGO" (at 0.75 0) (layer F.SilkS) hide + (effects (font (thickness 0.3))) + ) + (fp_poly (pts (xy 4.008792 -12.306448) (xy 4.197112 -12.007480) (xy 4.404044 -11.544210) (xy 4.495193 -11.310908) (xy 4.645632 -10.936371) (xy 4.784941 -10.627718) (xy 4.898265 -10.415388) (xy 4.970751 -10.329822) + (xy 4.974167 -10.329363) (xy 5.050092 -10.252351) (xy 5.079949 -10.045593) (xy 5.080000 -10.034713) (xy 5.113317 -9.755915) (xy 5.195135 -9.454602) (xy 5.211393 -9.411710) (xy 5.267201 -9.250425) + (xy 5.296179 -9.086173) (xy 5.298526 -8.878855) (xy 5.274438 -8.588374) (xy 5.224113 -8.174631) (xy 5.217722 -8.125525) (xy 5.092658 -7.167724) (xy 6.032483 -5.933362) (xy 6.332372 -5.539501) + (xy 6.595504 -5.193938) (xy 6.805253 -4.918506) (xy 6.944992 -4.735039) (xy 6.997831 -4.665712) (xy 7.091364 -4.665750) (xy 7.304027 -4.711479) (xy 7.595899 -4.790485) (xy 7.927058 -4.890351) + (xy 8.257583 -4.998662) (xy 8.547553 -5.103002) (xy 8.757046 -5.190955) (xy 8.835840 -5.237342) (xy 8.974014 -5.408051) (xy 9.138994 -5.680530) (xy 9.305645 -6.003434) (xy 9.448830 -6.325416) + (xy 9.543412 -6.595131) (xy 9.567334 -6.731543) (xy 9.621743 -6.920752) (xy 9.750929 -7.012322) (xy 9.903831 -6.975306) (xy 9.930738 -6.951796) (xy 9.984745 -6.830536) (xy 9.925047 -6.687702) + (xy 9.863269 -6.505829) (xy 9.826150 -6.236452) (xy 9.821334 -6.102854) (xy 9.846313 -5.810759) (xy 9.931342 -5.650976) (xy 10.091553 -5.620288) (xy 10.342079 -5.715478) (xy 10.678968 -5.920542) + (xy 10.977005 -6.115371) (xy 11.166712 -6.222050) (xy 11.278384 -6.249676) (xy 11.342316 -6.207344) (xy 11.378883 -6.130693) (xy 11.390757 -5.945180) (xy 11.262293 -5.850421) (xy 11.178118 -5.842000) + (xy 11.028157 -5.774518) (xy 10.845381 -5.606436) (xy 10.671308 -5.389302) (xy 10.547456 -5.174661) (xy 10.514483 -5.018067) (xy 10.603837 -4.893628) (xy 10.791938 -4.759518) (xy 11.022617 -4.643398) + (xy 11.239706 -4.572926) (xy 11.387038 -4.575764) (xy 11.398102 -4.582931) (xy 11.543923 -4.621711) (xy 11.695131 -4.571846) (xy 11.767317 -4.462096) (xy 11.767370 -4.457108) (xy 11.711584 -4.258201) + (xy 11.571384 -4.188517) (xy 11.446334 -4.224592) (xy 11.232943 -4.292421) (xy 10.961049 -4.320264) (xy 10.686957 -4.310168) (xy 10.466973 -4.264179) (xy 10.357659 -4.185027) (xy 10.385497 -4.056494) + (xy 10.506628 -3.868428) (xy 10.680968 -3.665621) (xy 10.868434 -3.492869) (xy 11.028942 -3.394964) (xy 11.072072 -3.386666) (xy 11.156678 -3.328096) (xy 11.159805 -3.196456) (xy 11.096428 -3.057855) + (xy 10.981522 -2.978401) (xy 10.979499 -2.978001) (xy 10.831494 -3.019731) (xy 10.781916 -3.114629) (xy 10.687751 -3.223310) (xy 10.475353 -3.370838) (xy 10.185155 -3.536905) (xy 9.857590 -3.701206) + (xy 9.533091 -3.843434) (xy 9.252090 -3.943281) (xy 9.057977 -3.980444) (xy 8.900327 -3.968530) (xy 8.612074 -3.935059) (xy 8.229900 -3.884706) (xy 7.790492 -3.822147) (xy 7.638629 -3.799537) + (xy 7.207910 -3.737089) (xy 6.841258 -3.688476) (xy 6.568964 -3.657362) (xy 6.421322 -3.647409) (xy 6.403881 -3.650260) (xy 6.352335 -3.730308) (xy 6.228652 -3.927343) (xy 6.049727 -4.214317) + (xy 5.832458 -4.564178) (xy 5.760223 -4.680749) (xy 5.535213 -5.038600) (xy 5.342323 -5.335072) (xy 5.198334 -5.545152) (xy 5.120027 -5.643829) (xy 5.111460 -5.647682) (xy 5.108142 -5.558319) + (xy 5.114837 -5.322827) (xy 5.130465 -4.964044) (xy 5.153947 -4.504810) (xy 5.184204 -3.967966) (xy 5.214635 -3.464599) (xy 5.348626 -1.312333) (xy 4.494901 0.325997) (xy 4.247641 0.809688) + (xy 4.033833 1.245714) (xy 3.864036 1.611031) (xy 3.748813 1.882597) (xy 3.698722 2.037370) (xy 3.699431 2.061664) (xy 3.764335 2.155813) (xy 3.914025 2.365870) (xy 4.133465 2.670960) + (xy 4.407619 3.050208) (xy 4.721450 3.482739) (xy 4.886202 3.709242) (xy 5.211588 4.158048) (xy 5.501956 4.562034) (xy 5.742876 4.900838) (xy 5.919918 5.154098) (xy 6.018652 5.301451) + (xy 6.034192 5.329213) (xy 5.974578 5.397200) (xy 5.796802 5.549089) (xy 5.520049 5.769738) (xy 5.163506 6.044007) (xy 4.746359 6.356755) (xy 4.529667 6.516513) (xy 4.087721 6.842454) + (xy 3.694126 7.136281) (xy 3.368695 7.382910) (xy 3.131242 7.567258) (xy 3.001582 7.674241) (xy 2.983499 7.693548) (xy 3.031808 7.781953) (xy 3.189871 7.923749) (xy 3.418502 8.091759) + (xy 3.678515 8.258807) (xy 3.930726 8.397718) (xy 4.106334 8.472264) (xy 4.412245 8.532817) (xy 4.852633 8.562141) (xy 5.291667 8.561172) (xy 5.699381 8.544809) (xy 5.975175 8.517608) + (xy 6.156416 8.472635) (xy 6.280471 8.402956) (xy 6.318106 8.370696) (xy 6.455348 8.260340) (xy 6.550458 8.266690) (xy 6.640475 8.345903) (xy 6.733970 8.503449) (xy 6.735869 8.611508) + (xy 6.693626 8.741251) (xy 6.688667 8.769925) (xy 6.614880 8.794702) (xy 6.436877 8.805327) (xy 6.431852 8.805334) (xy 6.209851 8.843847) (xy 5.922339 8.942397) (xy 5.749288 9.021077) + (xy 5.503488 9.156939) (xy 5.380292 9.266966) (xy 5.345425 9.389048) (xy 5.349936 9.462532) (xy 5.404373 9.617435) (xy 5.549696 9.764660) (xy 5.818351 9.936095) (xy 5.849987 9.953969) + (xy 6.135973 10.104049) (xy 6.394482 10.222203) (xy 6.539148 10.273783) (xy 6.740576 10.381449) (xy 6.823204 10.546402) (xy 6.764427 10.721065) (xy 6.598243 10.825684) (xy 6.423925 10.808936) + (xy 6.310694 10.677535) (xy 6.310540 10.677053) (xy 6.229600 10.573265) (xy 6.041563 10.490123) (xy 5.715668 10.414131) (xy 5.707930 10.412666) (xy 5.408003 10.360645) (xy 5.227642 10.348569) + (xy 5.120999 10.380156) (xy 5.042228 10.459119) (xy 5.036122 10.467114) (xy 4.956084 10.596938) (xy 4.920577 10.745522) (xy 4.925177 10.962647) (xy 4.963532 11.284063) (xy 5.024702 11.554672) + (xy 5.122900 11.688914) (xy 5.175385 11.711335) (xy 5.284364 11.775531) (xy 5.274491 11.913776) (xy 5.261470 11.951289) (xy 5.136793 12.131490) (xy 4.977230 12.180574) (xy 4.834055 12.097138) + (xy 4.772390 11.964663) (xy 4.703558 11.749624) (xy 4.593307 11.462588) (xy 4.521332 11.292838) (xy 4.376632 11.014322) (xy 4.236003 10.865797) (xy 4.112720 10.817832) (xy 3.992927 10.807882) + (xy 3.909496 10.856272) (xy 3.837014 10.996375) (xy 3.750065 11.261568) (xy 3.733853 11.315367) (xy 3.656769 11.620774) (xy 3.615975 11.883137) (xy 3.618542 12.031873) (xy 3.604244 12.217563) + (xy 3.486621 12.329447) (xy 3.322945 12.347405) (xy 3.170487 12.251316) (xy 3.137425 12.200891) (xy 3.102392 12.038553) (xy 3.185683 11.929135) (xy 3.245412 11.854815) (xy 3.279239 11.731973) + (xy 3.289678 11.527733) (xy 3.279244 11.209225) (xy 3.262465 10.925411) (xy 3.239090 10.590975) (xy 3.208115 10.322389) (xy 3.155655 10.091708) (xy 3.067826 9.870990) (xy 2.930743 9.632288) + (xy 2.730520 9.347660) (xy 2.453274 8.989161) (xy 2.085118 8.528847) (xy 2.049860 8.484966) (xy 1.838623 8.230376) (xy 1.677213 8.033819) (xy 1.573738 7.874506) (xy 1.536304 7.731646) + (xy 1.573018 7.584448) (xy 1.691989 7.412123) (xy 1.901321 7.193879) (xy 2.209124 6.908926) (xy 2.623503 6.536474) (xy 2.910989 6.276605) (xy 4.086311 5.208104) (xy 3.385888 4.551385) + (xy 3.102975 4.290276) (xy 2.865272 4.078676) (xy 2.699480 3.939842) (xy 2.633899 3.896326) (xy 2.570270 3.964205) (xy 2.439322 4.146134) (xy 2.262183 4.411767) (xy 2.119776 4.634828) + (xy 1.726054 5.188633) (xy 1.228388 5.777403) (xy 0.671240 6.354557) (xy 0.099071 6.873513) (xy -0.351238 7.223740) (xy -0.816039 7.519737) (xy -1.372154 7.822480) (xy -1.962521 8.104647) + (xy -2.530077 8.338915) (xy -3.005666 8.494765) (xy -3.577315 8.618661) (xy -4.222851 8.712809) (xy -4.876540 8.770592) (xy -5.472646 8.785393) (xy -5.760882 8.772109) (xy -6.773518 8.605423) + (xy -7.750544 8.280201) (xy -8.678015 7.805848) (xy -9.541983 7.191771) (xy -10.328505 6.447374) (xy -11.023634 5.582064) (xy -11.423444 4.953000) (xy -11.618595 4.614334) (xy -11.383689 4.910667) + (xy -11.097038 5.242669) (xy -10.728255 5.627146) (xy -10.314829 6.028936) (xy -9.894248 6.412875) (xy -9.504001 6.743799) (xy -9.181575 6.986544) (xy -9.144000 7.011478) (xy -8.301169 7.471008) + (xy -7.413523 7.792745) (xy -6.506325 7.972352) (xy -5.604838 8.005491) (xy -4.734323 7.887822) (xy -4.460300 7.815795) (xy -3.928496 7.625735) (xy -3.326712 7.358476) (xy -2.716103 7.043948) + (xy -2.157827 6.712081) (xy -2.024415 6.623671) (xy -1.568021 6.291266) (xy -1.159217 5.940970) (xy -0.777720 5.548590) (xy -0.403251 5.089936) (xy -0.015528 4.540817) (xy 0.405731 3.877043) + (xy 0.721031 3.348967) (xy 1.214673 2.506933) (xy 0.416836 1.766246) (xy 0.118329 1.497962) (xy -0.132987 1.288836) (xy -0.313654 1.157147) (xy -0.400215 1.121172) (xy -0.404075 1.126613) + (xy -0.420423 1.245302) (xy -0.448572 1.497282) (xy -0.484767 1.847228) (xy -0.525250 2.259812) (xy -0.531075 2.320866) (xy -0.635000 3.414065) (xy -1.993674 2.103840) (xy -2.453761 1.663339) + (xy -2.814034 1.327474) (xy -3.093861 1.080596) (xy -3.312614 0.907056) (xy -3.489664 0.791204) (xy -3.644379 0.717392) (xy -3.754993 0.680882) (xy -4.059333 0.627232) (xy -4.436269 0.605791) + (xy -4.839055 0.613764) (xy -5.220949 0.648357) (xy -5.535206 0.706776) (xy -5.735081 0.786228) (xy -5.752868 0.800293) (xy -5.890426 0.884312) (xy -6.026935 0.833959) (xy -6.047621 0.819224) + (xy -6.165791 0.658346) (xy -6.147055 0.495850) (xy -6.008391 0.390139) (xy -5.918991 0.376733) (xy -5.719942 0.341037) (xy -5.451712 0.254960) (xy -5.170139 0.141382) (xy -4.931064 0.023183) + (xy -4.790326 -0.076757) (xy -4.780521 -0.089756) (xy -4.744706 -0.290207) (xy -4.876575 -0.502113) (xy -5.174969 -0.723995) (xy -5.352301 -0.821142) (xy -5.640886 -0.963725) (xy -5.885397 -1.076887) + (xy -6.032500 -1.135985) (xy -6.153923 -1.244416) (xy -6.170799 -1.420877) (xy -6.079066 -1.591733) (xy -5.908012 -1.687696) (xy -5.768555 -1.630190) (xy -5.718099 -1.533763) (xy -5.613565 -1.414546) + (xy -5.368973 -1.306206) (xy -5.140893 -1.240937) (xy -4.851955 -1.171824) (xy -4.676694 -1.149327) (xy -4.565394 -1.175608) (xy -4.468336 -1.252832) (xy -4.449843 -1.271017) (xy -4.338189 -1.481930) + (xy -4.295208 -1.778327) (xy -4.318563 -2.092898) (xy -4.405918 -2.358337) (xy -4.491418 -2.468905) (xy -4.638202 -2.665836) (xy -4.623949 -2.857959) (xy -4.564860 -2.936606) (xy -4.414643 -2.996368) + (xy -4.251464 -2.956924) (xy -4.153709 -2.843006) (xy -4.148677 -2.805292) (xy -4.116256 -2.660350) (xy -4.031437 -2.415811) (xy -3.918170 -2.137833) (xy -3.784575 -1.851350) (xy -3.678589 -1.690432) + (xy -3.571148 -1.621077) (xy -3.465898 -1.608666) (xy -3.337283 -1.626621) (xy -3.246470 -1.705440) (xy -3.165577 -1.882562) (xy -3.092227 -2.110410) (xy -3.018068 -2.406957) (xy -2.981700 -2.660811) + (xy -2.986519 -2.788852) (xy -2.967814 -2.968704) (xy -2.843258 -3.077427) (xy -2.671303 -3.084860) (xy -2.552944 -3.012563) (xy -2.463307 -2.875893) (xy -2.509946 -2.726361) (xy -2.520488 -2.709113) + (xy -2.573431 -2.531320) (xy -2.608814 -2.209271) (xy -2.624203 -1.767369) (xy -2.624666 -1.665787) (xy -2.624666 -0.789277) (xy -1.970276 0.118391) (xy -1.731578 0.452595) (xy -1.552860 0.692516) + (xy -1.422511 0.828275) (xy -1.328915 0.849992) (xy -1.260462 0.747787) (xy -1.205538 0.511781) (xy -1.152530 0.132094) (xy -1.089825 -0.401154) (xy -1.059842 -0.656166) (xy -1.003816 -1.100655) + (xy -0.950156 -1.478847) (xy -0.903417 -1.762018) (xy -0.868156 -1.921444) (xy -0.855276 -1.945973) (xy -0.779810 -1.891350) (xy -0.598866 -1.739745) (xy -0.332103 -1.508256) (xy 0.000818 -1.213980) + (xy 0.380239 -0.874015) (xy 0.458770 -0.803132) (xy 0.842573 -0.458076) (xy 1.181285 -0.156974) (xy 1.455877 0.083538) (xy 1.647316 0.246823) (xy 1.736573 0.316246) (xy 1.740554 0.317341) + (xy 1.742207 0.230037) (xy 1.733942 0.004692) (xy 1.717208 -0.327785) (xy 1.693456 -0.736484) (xy 1.683933 -0.889000) (xy 1.660198 -1.345361) (xy 1.650815 -1.778933) (xy 1.656950 -2.227835) + (xy 1.679767 -2.730189) (xy 1.720432 -3.324116) (xy 1.780111 -4.047739) (xy 1.780676 -4.054250) (xy 1.828135 -4.613729) (xy 1.868370 -5.114142) (xy 1.899657 -5.531778) (xy 1.920272 -5.842928) + (xy 1.928489 -6.023881) (xy 1.926587 -6.060301) (xy 1.847266 -6.031503) (xy 1.649779 -5.933955) (xy 1.363159 -5.782622) (xy 1.016435 -5.592466) (xy 0.986118 -5.575549) (xy 0.636329 -5.383178) + (xy 0.344837 -5.228696) (xy 0.140462 -5.126955) (xy 0.052021 -5.092809) (xy 0.050775 -5.093497) (xy -0.084486 -5.265183) (xy -0.297331 -5.519122) (xy -0.565672 -5.830555) (xy -0.867421 -6.174721) + (xy -1.180491 -6.526861) (xy -1.482793 -6.862215) (xy -1.752240 -7.156024) (xy -1.966744 -7.383528) (xy -2.104217 -7.519968) (xy -2.137516 -7.546491) (xy -2.426226 -7.678799) (xy -2.762183 -7.799976) + (xy -3.099463 -7.897437) (xy -3.392138 -7.958596) (xy -3.594284 -7.970865) (xy -3.640942 -7.958519) (xy -3.807467 -7.944113) (xy -3.933264 -8.046007) (xy -3.962151 -8.211873) (xy -3.951489 -8.247772) + (xy -3.891739 -8.310323) (xy -3.752101 -8.338704) (xy -3.498886 -8.336639) (xy -3.277501 -8.322266) (xy -2.956151 -8.300904) (xy -2.764697 -8.303008) (xy -2.664348 -8.337280) (xy -2.616310 -8.412421) + (xy -2.598038 -8.474684) (xy -2.591908 -8.662391) (xy -2.681429 -8.871965) (xy -2.882455 -9.131414) (xy -3.097960 -9.357649) (xy -3.290062 -9.593732) (xy -3.348354 -9.773902) (xy -3.271731 -9.881951) + (xy -3.135324 -9.906000) (xy -2.990623 -9.846983) (xy -2.963182 -9.757833) (xy -2.891514 -9.617542) (xy -2.712054 -9.456806) (xy -2.477753 -9.308432) (xy -2.241560 -9.205227) (xy -2.056426 -9.179999) + (xy -2.037813 -9.184488) (xy -1.903603 -9.302147) (xy -1.788074 -9.526172) (xy -1.710830 -9.793598) (xy -1.691474 -10.041462) (xy -1.728163 -10.179053) (xy -1.768266 -10.342283) (xy -1.718071 -10.423129) + (xy -1.565487 -10.486942) (xy -1.427232 -10.421450) (xy -1.363442 -10.260369) (xy -1.364419 -10.224846) (xy -1.371645 -10.027713) (xy -1.371140 -9.745478) (xy -1.367834 -9.598375) (xy -1.347171 -9.328831) + (xy -1.295538 -9.184657) (xy -1.196962 -9.122553) (xy -1.191779 -9.121153) (xy -1.041410 -9.159003) (xy -0.853374 -9.307554) (xy -0.665819 -9.526094) (xy -0.516892 -9.773913) (xy -0.470429 -9.890996) + (xy -0.367123 -10.041468) (xy -0.226426 -10.059102) (xy -0.070309 -9.982436) (xy -0.017853 -9.852691) (xy -0.083045 -9.732959) (xy -0.147127 -9.701381) (xy -0.244094 -9.600287) (xy -0.363217 -9.376690) + (xy -0.489137 -9.073214) (xy -0.606496 -8.732482) (xy -0.699935 -8.397117) (xy -0.754096 -8.109741) (xy -0.761648 -7.995958) (xy -0.708977 -7.783194) (xy -0.558471 -7.462639) (xy -0.320743 -7.056549) + (xy -0.291795 -7.010859) (xy 0.177706 -6.274718) (xy 1.083686 -6.748646) (xy 1.440256 -6.936849) (xy 1.741750 -7.099134) (xy 1.956427 -7.218197) (xy 2.052542 -7.276736) (xy 2.052596 -7.276782) + (xy 2.071864 -7.378344) (xy 2.075562 -7.611689) (xy 2.064035 -7.940014) (xy 2.043409 -8.255007) (xy 2.014001 -8.680171) (xy 2.006037 -8.979515) (xy 2.022315 -9.195521) (xy 2.065631 -9.370673) + (xy 2.126787 -9.521345) (xy 2.226646 -9.802804) (xy 2.280965 -10.075418) (xy 2.284141 -10.132625) (xy 2.326472 -10.353958) (xy 2.419538 -10.428958) (xy 2.508462 -10.513964) (xy 2.645849 -10.725041) + (xy 2.813924 -11.032423) (xy 2.966776 -11.345333) (xy 3.224719 -11.864203) (xy 3.447046 -12.219994) (xy 3.644604 -12.412461) (xy 3.828238 -12.441361) (xy 4.008792 -12.306448) )(layer F.Mask) (width 0.010000) + ) +) diff --git a/Sofle_RGB_v3/PCB/custom mods/gecko-logo.kicad_mod b/Sofle_RGB_v3/PCB/custom mods/gecko-logo.kicad_mod new file mode 100644 index 00000000..f4014169 --- /dev/null +++ b/Sofle_RGB_v3/PCB/custom mods/gecko-logo.kicad_mod @@ -0,0 +1,86 @@ +(module LOGO (layer F.Cu) + (at 0 0) + (fp_text reference "G***" (at 0 0) (layer F.SilkS) hide + (effects (font (thickness 0.3))) + ) + (fp_text value "LOGO" (at 0.75 0) (layer F.SilkS) hide + (effects (font (thickness 0.3))) + ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.506840) (xy 0.762000 -1.505208) (xy 0.766997 -1.463388) (xy 0.779270 -1.418191) (xy 0.781708 -1.411757) (xy 0.790080 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.749800) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) (xy 1.346102 -0.811208) (xy 1.370849 -0.852080) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.989270) (xy 1.435100 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) (xy 1.485574 -1.046296) (xy 1.489610 -1.042770) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.479490 -0.975875) (xy 1.473922 -0.935468) (xy 1.473200 -0.915429) (xy 1.476946 -0.871614) (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.646550 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.876300) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.776200) (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.618790 -0.713928) (xy 1.653392 -0.696510) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.687440) (xy 1.731588 -0.693257) (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.716950 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.648040) (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) (xy 1.660810 -0.508000) (xy 1.673501 -0.499215) (xy 1.673970 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.452960) (xy 1.617287 -0.467195) (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.595280) (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) (xy 0.960582 -0.547539) (xy 0.952850 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) (xy 0.779750 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.777630 -0.595195) (xy 0.782195 -0.519690) (xy 0.802293 -0.196850) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) (xy 0.554914 0.309249) (xy 0.564650 0.323371) (xy 0.587103 0.354880) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.522410) (xy 0.732930 0.556386) (xy 0.781738 0.623707) (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.809580) (xy 0.869520 0.832363) (xy 0.828007 0.865460) (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.679450 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.478480 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.615950 1.270839) (xy 0.661836 1.279922) (xy 0.727894 1.284321) (xy 0.793750 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.942070 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.239050) (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.010380 1.291726) + (xy 1.004043 1.311187) (xy 1.003300 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) (xy 0.964777 1.320800) (xy 0.931477 1.326577) (xy 0.888350 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.373540) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.802490 1.419379) (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.533330) (xy 0.980872 1.541067) (xy 1.011086 1.557217) (xy 1.023480 1.581960) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.621340) + (xy 0.946604 1.601630) (xy 0.946580 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) (xy 0.857350 1.562119) (xy 0.856189 1.561899) (xy 0.811200 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.589540) (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.733200) + (xy 0.768434 1.753337) (xy 0.776307 1.756700) (xy 0.792654 1.766329) (xy 0.791173 1.787066) (xy 0.789220 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.814570) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) (xy 0.656494 1.652148) (xy 0.635400 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.628440) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) (xy 0.548515 1.743116) (xy 0.542396 1.782470) (xy 0.542781 1.804780) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.852110) (xy 0.475573 1.837697) (xy 0.470613 1.830133) (xy 0.465358 1.805782) (xy 0.477852 1.789370) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.236060 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) (xy 0.393525 0.980471) (xy 0.436648 0.941490) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.429790 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) (xy 0.385540 0.594630) (xy 0.365898 0.621920) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.866610) (xy 0.100686 0.953183) (xy 0.014860 1.031026) (xy -0.052686 1.083560) (xy -0.122406 1.127960) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.450850 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.242030) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) (xy -1.653546 0.837309) (xy -1.713517 0.742950) (xy -1.742790 0.692150) (xy -1.707554 0.736600) + (xy -1.664556 0.786400) (xy -1.609239 0.844071) (xy -1.547225 0.904340) (xy -1.484138 0.961931) (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.371600 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) (xy -0.669045 1.172369) (xy -0.589275 1.143860) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.993550) (xy -0.235204 0.943689) (xy -0.173883 0.891145) (xy -0.116659 0.832288) (xy -0.060488 0.763490) (xy -0.002330 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.182200 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) (xy -0.079662 0.348129) (xy -0.095250 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.249500) + (xy -0.422106 0.199121) (xy -0.464080 0.162089) (xy -0.496893 0.136058) (xy -0.523450 0.118680) (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.608900 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.058520) (xy -0.887849 0.056509) (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.739660 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) (xy -0.776246 -0.108600) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.882810 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.925620 -0.213132) (xy -0.911860 -0.238761) (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.172400) (xy -0.684810 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.222290) + (xy -0.644282 -0.266750) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.684730 -0.440491) (xy -0.662197 -0.449456) + (xy -0.637720 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.241300) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.462730) (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.393700 -0.249869) (xy -0.393700 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.232930 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.189070 0.112168) (xy -0.180831 0.076767) (xy -0.172880 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) (xy -0.116972 -0.283703) (xy -0.089830 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.120470) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) (xy 0.218381 0.012530) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) (xy 0.252589 -0.133350) (xy 0.249029 -0.201805) (xy 0.247622 -0.266840) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) (xy 0.274220 -0.692060) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.288040 -0.876440) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) (xy 0.204473 -0.867394) (xy 0.152465 -0.838870) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) (xy -0.012673 -0.789778) (xy -0.044600 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.979030) (xy -0.222420 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.107530) (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.151820) (xy -0.414328 -1.169997) + (xy -0.464920 -1.184616) (xy -0.508821 -1.193790) (xy -0.539143 -1.195630) (xy -0.546142 -1.193778) (xy -0.571121 -1.191617) (xy -0.589990 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.248340) (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) (xy -0.464694 -1.403648) (xy -0.493510 -1.439060) (xy -0.502254 -1.466086) (xy -0.490760 -1.482293) + (xy -0.470299 -1.485900) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377000) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.469040) (xy -0.253722 -1.506220) (xy -0.259225 -1.526859) (xy -0.265240 -1.551343) (xy -0.257711 -1.563470) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.483650) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) (xy -0.012457 -1.459944) (xy -0.022070 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) (xy -0.114248 -1.199394) (xy -0.106347 -1.167480) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.043770 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) (xy 0.261262 -1.064871) (xy 0.293464 -1.082730) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) (xy 0.302100 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) (xy 0.348970 -1.553094) (xy 0.362930 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.701800) (xy 0.483707 -1.779631) (xy 0.517056 -1.833000) (xy 0.546690 -1.861870) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968) )(layer F.Mask) (width 0.010000) + ) +) diff --git a/Sofle_RGB_v3/PCB/custom mods/logo.kicad_mod b/Sofle_RGB_v3/PCB/custom mods/logo.kicad_mod new file mode 100644 index 00000000..411661ac --- /dev/null +++ b/Sofle_RGB_v3/PCB/custom mods/logo.kicad_mod @@ -0,0 +1,86 @@ +(module LOGO (layer F.Cu) + (at 0 0) + (fp_text reference "G***" (at 0 0) (layer F.SilkS) hide + (effects (font (thickness 0.3))) + ) + (fp_text value "LOGO" (at 0.75 0) (layer F.SilkS) hide + (effects (font (thickness 0.3))) + ) + (fp_poly (pts (xy 5.644444 5.644444) (xy -5.644444 5.644444) (xy -5.644444 0.769056) (xy -1.935538 0.769056) (xy -1.902630 0.829609) (xy -1.856953 0.902284) (xy -1.795534 0.984102) (xy -1.725081 1.067105) + (xy -1.652303 1.143334) (xy -1.591683 1.198475) (xy -1.453105 1.297751) (xy -1.302627 1.377000) (xy -1.163368 1.427763) (xy -1.063382 1.448264) (xy -0.945727 1.459141) (xy -0.819258 1.460405) + (xy -0.692832 1.452068) (xy -0.575307 1.434142) (xy -0.543376 1.426961) (xy -0.367200 1.369889) (xy -0.196115 1.287393) (xy -0.033891 1.182238) (xy 0.115702 1.057192) (xy 0.248893 0.915021) + (xy 0.357051 0.766220) (xy 0.389203 0.716725) (xy 0.416083 0.677646) (xy 0.434020 0.654199) (xy 0.438983 0.649803) (xy 0.452080 0.658621) (xy 0.481120 0.683082) (xy 0.521655 0.719319) + (xy 0.563937 0.758472) (xy 0.680296 0.867833) (xy 0.461207 1.065389) (xy 0.395732 1.124965) (xy 0.337958 1.178560) (xy 0.291000 1.223198) (xy 0.257976 1.255902) (xy 0.242003 1.273697) + (xy 0.241004 1.275659) (xy 0.248935 1.291057) (xy 0.271332 1.323404) (xy 0.304701 1.367878) (xy 0.343223 1.416770) (xy 0.405636 1.494617) (xy 0.452692 1.555190) (xy 0.486724 1.603204) + (xy 0.510064 1.643376) (xy 0.525046 1.680421) (xy 0.534000 1.719055) (xy 0.539261 1.763995) (xy 0.543161 1.819956) (xy 0.543237 1.821159) (xy 0.546950 1.889786) (xy 0.547453 1.935766) + (xy 0.544335 1.964531) (xy 0.537187 1.981517) (xy 0.530637 1.988446) (xy 0.516276 2.010815) (xy 0.522904 2.033482) (xy 0.546535 2.057256) (xy 0.578417 2.054275) (xy 0.591162 2.047339) + (xy 0.604320 2.024405) (xy 0.603126 2.005449) (xy 0.602831 1.976315) (xy 0.610081 1.931668) (xy 0.619499 1.894643) (xy 0.634843 1.848272) (xy 0.649161 1.822799) (xy 0.667289 1.811514) + (xy 0.681392 1.808835) (xy 0.703563 1.809131) (xy 0.720390 1.820039) (xy 0.737319 1.847194) (xy 0.754717 1.884674) (xy 0.773675 1.931725) (xy 0.786557 1.971705) (xy 0.790222 1.991865) + (xy 0.800125 2.018487) (xy 0.823833 2.029250) (xy 0.852348 2.024923) (xy 0.876673 2.006274) (xy 0.886699 1.983626) (xy 0.879210 1.960312) (xy 0.863237 1.952065) (xy 0.846250 1.942166) + (xy 0.835128 1.918982) (xy 0.827160 1.875947) (xy 0.825164 1.859775) (xy 0.820793 1.810107) (xy 0.823034 1.779183) (xy 0.833318 1.758006) (xy 0.843072 1.747101) (xy 0.860775 1.732227) + (xy 0.880568 1.726145) (xy 0.911097 1.728035) (xy 0.957136 1.736316) (xy 1.011055 1.749732) (xy 1.041411 1.764940) (xy 1.051836 1.779759) (xy 1.070618 1.801521) (xy 1.099633 1.804284) + (xy 1.127304 1.786965) (xy 1.127404 1.786844) (xy 1.137041 1.757425) (xy 1.123423 1.729689) (xy 1.095835 1.714066) (xy 1.056961 1.699467) (xy 1.009309 1.676669) (xy 0.962006 1.650636) + (xy 0.924180 1.626332) (xy 0.906639 1.611176) (xy 0.889572 1.577911) (xy 0.896983 1.548214) (xy 0.930256 1.519235) (xy 0.959086 1.503071) (xy 1.006906 1.482762) (xy 1.052054 1.469908) + (xy 1.071975 1.467556) (xy 1.101927 1.465860) (xy 1.114770 1.461770) (xy 1.114778 1.461654) (xy 1.119145 1.444991) (xy 1.122645 1.435251) (xy 1.119840 1.410312) (xy 1.106746 1.390984) + (xy 1.087917 1.375815) (xy 1.071541 1.379362) (xy 1.053018 1.395250) (xy 1.034463 1.408622) (xy 1.008938 1.417404) (xy 0.970194 1.422744) (xy 0.911978 1.425786) (xy 0.881944 1.426614) + (xy 0.800360 1.426137) (xy 0.732233 1.421014) (xy 0.684792 1.411792) (xy 0.684389 1.411662) (xy 0.648536 1.396090) (xy 0.605879 1.371999) (xy 0.562964 1.343918) (xy 0.526337 1.316372) + (xy 0.502543 1.293888) (xy 0.497250 1.282258) (xy 0.509227 1.271391) (xy 0.540729 1.246443) (xy 0.588454 1.209927) (xy 0.649100 1.164358) (xy 0.719363 1.112249) (xy 0.754944 1.086085) + (xy 0.828182 1.031711) (xy 0.892821 0.982438) (xy 0.945669 0.940806) (xy 0.983531 0.909358) (xy 1.003215 0.890634) (xy 1.005268 0.886910) (xy 0.996209 0.872233) (xy 0.972857 0.838236) + (xy 0.937634 0.788339) (xy 0.892964 0.725960) (xy 0.841270 0.654517) (xy 0.813876 0.616915) (xy 0.759255 0.541985) (xy 0.710046 0.474238) (xy 0.668761 0.417152) (xy 0.637910 0.374205) + (xy 0.620005 0.348874) (xy 0.616738 0.343978) (xy 0.620229 0.327340) (xy 0.635273 0.289652) (xy 0.660108 0.234745) (xy 0.692974 0.166454) (xy 0.732110 0.088612) (xy 0.749625 0.054700) + (xy 0.891933 -0.218722) (xy 0.869680 -0.577760) (xy 0.863816 -0.675282) (xy 0.858881 -0.763088) (xy 0.855061 -0.837379) (xy 0.852540 -0.894361) (xy 0.851504 -0.930236) (xy 0.851941 -0.941311) + (xy 0.860511 -0.931647) (xy 0.880979 -0.902015) (xy 0.910598 -0.856573) (xy 0.946622 -0.799478) (xy 0.960921 -0.776397) (xy 1.000922 -0.713858) (xy 1.036756 -0.662189) (xy 1.065365 -0.625512) + (xy 1.083691 -0.607952) (xy 1.086556 -0.607023) (xy 1.107924 -0.609113) (xy 1.151169 -0.614788) (xy 1.210295 -0.623215) (xy 1.279302 -0.633565) (xy 1.289602 -0.635150) (xy 1.361327 -0.645795) + (xy 1.425800 -0.654588) (xy 1.476381 -0.660673) (xy 1.506429 -0.663198) (xy 1.508098 -0.663222) (xy 1.541663 -0.656913) (xy 1.589033 -0.640225) (xy 1.643468 -0.616522) (xy 1.698229 -0.589167) + (xy 1.746574 -0.561521) (xy 1.781764 -0.536948) (xy 1.796986 -0.519105) (xy 1.813427 -0.497634) (xy 1.829916 -0.496334) (xy 1.849176 -0.509346) (xy 1.859885 -0.532380) (xy 1.859547 -0.554418) + (xy 1.845667 -0.564442) (xy 1.845345 -0.564444) (xy 1.821218 -0.574609) (xy 1.790575 -0.600080) (xy 1.760067 -0.633324) (xy 1.736347 -0.666807) (xy 1.726066 -0.692996) (xy 1.726757 -0.698756) + (xy 1.737363 -0.712090) (xy 1.760302 -0.717867) (xy 1.802474 -0.717451) (xy 1.816843 -0.716539) (xy 1.865616 -0.711620) (xy 1.905192 -0.704928) (xy 1.921364 -0.700155) (xy 1.942434 -0.699354) + (xy 1.954624 -0.720408) (xy 1.954648 -0.751768) (xy 1.932098 -0.768209) (xy 1.891553 -0.768251) (xy 1.853377 -0.770657) (xy 1.810852 -0.785450) (xy 1.774188 -0.807638) (xy 1.753593 -0.832227) + (xy 1.752426 -0.836282) (xy 1.758403 -0.863523) (xy 1.779435 -0.899472) (xy 1.808606 -0.935538) (xy 1.838999 -0.963128) (xy 1.863020 -0.973667) (xy 1.892871 -0.982827) (xy 1.900146 -1.008283) + (xy 1.896480 -1.021782) (xy 1.888538 -1.036954) (xy 1.876616 -1.041661) (xy 1.855665 -1.034387) (xy 1.820637 -1.013615) (xy 1.779828 -0.986757) (xy 1.721371 -0.951386) (xy 1.680371 -0.936484) + (xy 1.654307 -0.942586) (xy 1.640657 -0.970228) (xy 1.636889 -1.017142) (xy 1.640313 -1.064199) (xy 1.648978 -1.103056) (xy 1.654174 -1.114617) (xy 1.664185 -1.141240) (xy 1.655123 -1.158633) + (xy 1.629842 -1.169349) (xy 1.606934 -1.157677) (xy 1.594908 -1.128774) (xy 1.594556 -1.121924) (xy 1.587548 -1.089022) (xy 1.569320 -1.041034) (xy 1.544060 -0.986518) (xy 1.515958 -0.934032) + (xy 1.489203 -0.892132) (xy 1.472640 -0.872890) (xy 1.451576 -0.861497) (xy 1.412285 -0.845876) (xy 1.361422 -0.828096) (xy 1.305640 -0.810227) (xy 1.251592 -0.794337) (xy 1.205932 -0.782496) + (xy 1.175313 -0.776773) (xy 1.166305 -0.777619) (xy 1.156803 -0.790086) (xy 1.132978 -0.821368) (xy 1.097601 -0.867823) (xy 1.053447 -0.925809) (xy 1.005580 -0.988677) (xy 0.849109 -1.194187) + (xy 0.870667 -1.352836) (xy 0.879814 -1.423573) (xy 0.884530 -1.473301) (xy 0.884776 -1.508890) (xy 0.880514 -1.537209) (xy 0.871704 -1.565128) (xy 0.869446 -1.571131) (xy 0.854971 -1.619443) + (xy 0.847128 -1.665879) (xy 0.846667 -1.676166) (xy 0.841757 -1.708976) (xy 0.829028 -1.721561) (xy 0.817565 -1.734010) (xy 0.799107 -1.767972) (xy 0.776131 -1.818373) (xy 0.751112 -1.880140) + (xy 0.749199 -1.885151) (xy 0.712948 -1.973415) (xy 0.680528 -2.034278) (xy 0.650132 -2.067782) (xy 0.619951 -2.073968) (xy 0.588177 -2.052876) (xy 0.553005 -2.004547) (xy 0.512625 -1.929021) + (xy 0.494463 -1.890889) (xy 0.464438 -1.829960) (xy 0.437023 -1.780889) (xy 0.415181 -1.748636) (xy 0.403256 -1.738160) (xy 0.385539 -1.720832) (xy 0.380690 -1.688771) (xy 0.374480 -1.647211) + (xy 0.359386 -1.598694) (xy 0.353797 -1.585400) (xy 0.342008 -1.555932) (xy 0.335231 -1.526421) (xy 0.332979 -1.489693) (xy 0.334764 -1.438576) (xy 0.339449 -1.373989) (xy 0.344463 -1.305880) + (xy 0.346243 -1.260504) (xy 0.344409 -1.232516) (xy 0.338579 -1.216570) (xy 0.328373 -1.207323) (xy 0.327537 -1.206819) (xy 0.305584 -1.194489) (xy 0.265018 -1.172283) (xy 0.212118 -1.143621) + (xy 0.166592 -1.119123) (xy 0.029795 -1.045729) (xy -0.048603 -1.169976) (xy -0.086801 -1.234663) (xy -0.113494 -1.288591) (xy -0.126253 -1.326667) (xy -0.127000 -1.334188) (xy -0.122211 -1.374884) + (xy -0.109564 -1.427274) (xy -0.091639 -1.484239) (xy -0.071017 -1.538661) (xy -0.050278 -1.583421) (xy -0.032003 -1.611400) (xy -0.024521 -1.616897) (xy -0.004931 -1.633123) (xy -0.005906 -1.655334) + (xy -0.025115 -1.673016) (xy -0.037738 -1.676517) (xy -0.065463 -1.670632) (xy -0.078412 -1.648476) (xy -0.097176 -1.609727) (xy -0.125920 -1.571108) (xy -0.158100 -1.539497) (xy -0.187170 -1.521769) + (xy -0.200138 -1.520587) (xy -0.213529 -1.528019) (xy -0.221328 -1.545679) (xy -0.224941 -1.579675) (xy -0.225778 -1.631922) (xy -0.227129 -1.689007) (xy -0.231905 -1.723507) (xy -0.241189 -1.740960) + (xy -0.247893 -1.745039) (xy -0.276387 -1.744955) (xy -0.292661 -1.726287) (xy -0.289054 -1.698299) (xy -0.288027 -1.696509) (xy -0.281630 -1.664821) (xy -0.287389 -1.621817) (xy -0.302037 -1.577991) + (xy -0.322306 -1.543837) (xy -0.339636 -1.530748) (xy -0.368620 -1.532725) (xy -0.407335 -1.548455) (xy -0.446954 -1.572468) (xy -0.478654 -1.599299) (xy -0.493609 -1.623477) (xy -0.493864 -1.626306) + (xy -0.505303 -1.647073) (xy -0.522554 -1.651000) (xy -0.551354 -1.643134) (xy -0.557538 -1.621336) (xy -0.541290 -1.588306) (xy -0.516327 -1.559608) (xy -0.468520 -1.508808) (xy -0.440766 -1.470641) + (xy -0.430698 -1.440597) (xy -0.435952 -1.414163) (xy -0.437965 -1.410139) (xy -0.448990 -1.393931) (xy -0.464866 -1.385510) (xy -0.492841 -1.383430) (xy -0.540163 -1.386243) (xy -0.552591 -1.387266) + (xy -0.606680 -1.390561) (xy -0.638763 -1.388745) (xy -0.654708 -1.381134) (xy -0.658480 -1.374894) (xy -0.658083 -1.346007) (xy -0.639656 -1.326147) (xy -0.612465 -1.323984) (xy -0.606725 -1.326473) + (xy -0.577692 -1.331270) (xy -0.531105 -1.322020) (xy -0.503125 -1.313083) (xy -0.445907 -1.292431) (xy -0.399395 -1.272151) (xy -0.358828 -1.248539) (xy -0.319446 -1.217889) (xy -0.276490 -1.176497) + (xy -0.225198 -1.120658) (xy -0.160819 -1.046678) (xy -0.107537 -0.984696) (xy -0.060970 -0.930440) (xy -0.024102 -0.887393) (xy 0.000083 -0.859037) (xy 0.008570 -0.848916) (xy 0.021408 -0.853537) + (xy 0.053981 -0.869633) (xy 0.101490 -0.894728) (xy 0.159135 -0.926347) (xy 0.164353 -0.929258) (xy 0.222727 -0.961390) (xy 0.271449 -0.987291) (xy 0.305691 -1.004460) (xy 0.320623 -1.010395) + (xy 0.320842 -1.010306) (xy 0.320824 -0.995704) (xy 0.318544 -0.956967) (xy 0.314299 -0.898067) (xy 0.308384 -0.822974) (xy 0.301095 -0.735661) (xy 0.296273 -0.680072) (xy 0.286213 -0.559439) + (xy 0.279377 -0.460277) (xy 0.275563 -0.376047) (xy 0.274568 -0.300205) (xy 0.276190 -0.226212) (xy 0.279934 -0.152275) (xy 0.284155 -0.080200) (xy 0.287383 -0.019018) (xy 0.289378 0.026174) + (xy 0.289897 0.050280) (xy 0.289649 0.052863) (xy 0.278921 0.044917) (xy 0.250500 0.020730) (xy 0.207546 -0.016922) (xy 0.153220 -0.065265) (xy 0.090682 -0.121521) (xy 0.076771 -0.134109) + (xy 0.012459 -0.191988) (xy -0.044769 -0.242786) (xy -0.091637 -0.283652) (xy -0.124870 -0.311737) (xy -0.141192 -0.324191) (xy -0.142130 -0.324556) (xy -0.146804 -0.311358) (xy -0.153809 -0.275070) + (xy -0.162329 -0.220646) (xy -0.171547 -0.153041) (xy -0.175266 -0.123258) (xy -0.184833 -0.046860) (xy -0.194088 0.023129) (xy -0.202128 0.080138) (xy -0.208049 0.117596) (xy -0.209243 0.123873) + (xy -0.218722 0.169708) (xy -0.328083 0.019283) (xy -0.437444 -0.131141) (xy -0.437444 -0.277429) (xy -0.435604 -0.354714) (xy -0.430351 -0.412802) (xy -0.422089 -0.447648) (xy -0.420081 -0.451519) + (xy -0.410345 -0.477390) (xy -0.423173 -0.499730) (xy -0.425491 -0.502094) (xy -0.453857 -0.515825) (xy -0.481210 -0.509120) (xy -0.497811 -0.487007) (xy -0.497753 -0.464809) (xy -0.497595 -0.435922) + (xy -0.505083 -0.391273) (xy -0.515371 -0.351735) (xy -0.530714 -0.305336) (xy -0.544104 -0.280111) (xy -0.560236 -0.269810) (xy -0.578193 -0.268111) (xy -0.600700 -0.271677) (xy -0.618244 -0.286358) + (xy -0.636093 -0.318132) (xy -0.649712 -0.349250) (xy -0.669443 -0.396798) (xy -0.680804 -0.426537) (xy -0.686475 -0.446631) (xy -0.689132 -0.465242) (xy -0.689681 -0.471076) (xy -0.703141 -0.490502) + (xy -0.730032 -0.498970) (xy -0.756547 -0.492918) (xy -0.760810 -0.489434) (xy -0.775323 -0.458882) (xy -0.762754 -0.425991) (xy -0.748570 -0.411484) (xy -0.727578 -0.377985) (xy -0.717011 -0.329325) + (xy -0.717259 -0.276724) (xy -0.728709 -0.231398) (xy -0.741641 -0.211836) (xy -0.758233 -0.197499) (xy -0.775802 -0.191713) (xy -0.802635 -0.194118) (xy -0.847018 -0.204353) (xy -0.856816 -0.206823) + (xy -0.913451 -0.224524) (xy -0.944888 -0.243097) (xy -0.953017 -0.255627) (xy -0.970680 -0.279036) (xy -0.997008 -0.277413) (xy -1.013178 -0.265289) (xy -1.028591 -0.236181) (xy -1.025418 -0.206905) + (xy -1.005417 -0.189370) (xy -0.979778 -0.179256) (xy -0.939203 -0.160712) (xy -0.904915 -0.143951) (xy -0.845728 -0.108075) (xy -0.807476 -0.071549) (xy -0.792766 -0.037268) (xy -0.795016 -0.021974) + (xy -0.812752 -0.004368) (xy -0.848944 0.016761) (xy -0.894815 0.037527) (xy -0.941587 0.054045) (xy -0.980484 0.062430) (xy -0.986499 0.062789) (xy -1.017122 0.073570) (xy -1.028940 0.097883) + (xy -1.019122 0.125992) (xy -1.007937 0.136537) (xy -0.984009 0.147734) (xy -0.962441 0.136649) (xy -0.960541 0.134958) (xy -0.934551 0.123509) (xy -0.886313 0.113274) (xy -0.821799 0.105487) + (xy -0.815212 0.104933) (xy -0.751798 0.100530) (xy -0.699418 0.100102) (xy -0.654000 0.105718) (xy -0.611474 0.119449) (xy -0.567768 0.143366) (xy -0.518812 0.179540) (xy -0.460534 0.230041) + (xy -0.388864 0.296939) (xy -0.333356 0.350017) (xy -0.105833 0.568368) (xy -0.088513 0.386489) (xy -0.081709 0.316791) (xy -0.075534 0.256706) (xy -0.070615 0.212127) (xy -0.067580 0.188950) + (xy -0.067346 0.187769) (xy -0.056317 0.190413) (xy -0.028865 0.209585) (xy 0.011098 0.242237) (xy 0.059665 0.285324) (xy 0.069473 0.294374) (xy 0.202445 0.417822) (xy 0.120301 0.558161) + (xy 0.038754 0.692424) (xy -0.036366 0.804257) (xy -0.108561 0.897650) (xy -0.181335 0.976588) (xy -0.258193 1.045060) (xy -0.342639 1.107053) (xy -0.387480 1.136044) (xy -0.553925 1.227189) + (xy -0.716407 1.290469) (xy -0.875425 1.325888) (xy -1.031474 1.333449) (xy -1.185053 1.313154) (xy -1.336657 1.265007) (xy -1.486785 1.189011) (xy -1.557501 1.143310) (xy -1.628762 1.088412) + (xy -1.708490 1.017766) (xy -1.788985 0.938758) (xy -1.862547 0.858774) (xy -1.896146 0.818444) (xy -1.935538 0.769056) (xy -5.644444 0.769056) (xy -5.644444 -5.644444) (xy 5.644444 -5.644444) + (xy 5.644444 5.644444) )(layer Eco2.User) (width 0.010000) + ) +) diff --git a/Sofle_RGB_v3/PCB/fp-info-cache b/Sofle_RGB_v3/PCB/fp-info-cache new file mode 100644 index 00000000..0457b29a --- /dev/null +++ b/Sofle_RGB_v3/PCB/fp-info-cache @@ -0,0 +1,83161 @@ +19440712348276718 +Battery +BatteryHolder_Bulgin_BX0036_1xC +Bulgin Battery Holder, BX0036, Battery Type C (https://www.bulgin.com/products/pub/media/bulgin/data/Battery_holders.pdf) +Bulgin BX0036 +0 +2 +2 +Battery +BatteryHolder_ComfortableElectronic_CH273-2450_1x2450 +Comfortable Electronic CR2450 battery holder, http://www.comf.com.tw/ProductDetail.asp?no=148 +Comfortable Electronic CR2450 +0 +2 +2 +Battery +BatteryHolder_Eagle_12BH611-GR +https://eu.mouser.com/datasheet/2/209/EPD-200766-1274481.pdf +9V Battery Holder +0 +2 +2 +Battery +BatteryHolder_Keystone_103_1x20mm +http://www.keyelco.com/product-pdf.cfm?p=719 +Keystone type 103 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_104_1x23mm +http://www.keyelco.com/product-pdf.cfm?p=744 +Keystone type 104 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_105_1x2430 +http://www.keyelco.com/product-pdf.cfm?p=745 +Keystone type 105 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_106_1x20mm +http://www.keyelco.com/product-pdf.cfm?p=720 +Keystone type 106 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_107_1x23mm +http://www.keyelco.com/product-pdf.cfm?p=746 +Keystone type 107 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_500 +Keystone #500, CR1220 battery holder, http://www.keyelco.com/product-pdf.cfm?p=710 +CR1220 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_1042_1x18650 +Battery holder for 18650 cylindrical cells http://www.keyelco.com/product.cfm/product_id/918 +18650 Keystone 1042 Li-ion +0 +2 +2 +Battery +BatteryHolder_Keystone_1058_1x2032 +http://www.keyelco.com/product-pdf.cfm?p=14028 +Keystone type 1058 coin cell retainer +0 +2 +2 +Battery +BatteryHolder_Keystone_1060_1x2032 +http://www.keyelco.com/product-pdf.cfm?p=726 +CR2032 BR2032 BatteryHolder Battery +0 +2 +2 +Battery +BatteryHolder_Keystone_2460_1xAA +https://www.keyelco.com/product-pdf.cfm?p=1025 +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2462_2xAA +2xAA cell battery holder, Keystone P/N 2462, https://www.keyelco.com/product-pdf.cfm?p=1027 +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2466_1xAAA +1xAAA Battery Holder, Keystone, Plastic Case, http://www.keyelco.com/product-pdf.cfm?p=1031 +AAA battery holder Keystone +0 +2 +2 +Battery +BatteryHolder_Keystone_2468_2xAAA +2xAAA cell battery holder, Keystone P/N 2468, http://www.keyelco.com/product-pdf.cfm?p=1033 +AAA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2479_3xAAA +Keystone Battery Holder, 2479, Battery Type 3xAAA (Script generated with StandardBox.py) (Keystone Battery Holder, 2479, Battery Type 3xAAA) +Keystone Battery Holder 2479 Battery Type 3xAAA +0 +2 +2 +Battery +BatteryHolder_Keystone_2993 +http://www.keyelco.com/product-pdf.cfm?p=776 +Keystone type 2993 negative battery contact +0 +1 +1 +Battery +BatteryHolder_Keystone_2998_1x6.8mm +www.keyelco.com/product-pdf.cfm?p=763 +Keystone type 2998 battery holder +0 +3 +2 +Battery +BatteryHolder_Keystone_3000_1x12mm +http://www.keyelco.com/product-pdf.cfm?p=777 +Keystone type 3000 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3001_1x12mm +http://www.keyelco.com/product-pdf.cfm?p=778 +Keystone type 3001 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3002_1x2032 +https://www.tme.eu/it/Document/a823211ec201a9e209042d155fe22d2b/KEYS2996.pdf +BR2016 CR2016 DL2016 BR2020 CL2020 BR2025 CR2025 DL2025 DR2032 CR2032 DL2032 +0 +3 +2 +Battery +BatteryHolder_Keystone_3008_1x2450 +http://www.keyelco.com/product-pdf.cfm?p=786 +Keystone type 3008 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3009_1x2450 +http://www.keyelco.com/product-pdf.cfm?p=787 +Keystone type 3009 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3034_1x20mm +Keystone 3034 SMD battery holder for 2020, 2025 and 2032 coincell batteries. http://www.keyelco.com/product-pdf.cfm?p=798 +Keystone type 3034 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_LINX_BAT-HLD-012-SMT +SMT battery holder for CR1216/1220/1225, https://linxtechnologies.com/wp/wp-content/uploads/bat-hld-012-smt.pdf +battery holder coin cell cr1216 cr1220 cr1225 +0 +3 +2 +Battery +BatteryHolder_MPD_BA9VPC_1xPP3 +1xPP3 (9V) battery holder, Memory Protection Devices P/N BA9VPC, http://www.memoryprotectiondevices.com/datasheets/BA9VPC-datasheet.pdf +PP3 Battery Holder BA9VPC 9V +0 +2 +2 +Battery +BatteryHolder_MPD_BC2AAPC_2xAA +2xAA cell battery holder, Memory Protection Devices P/N BC2AAPC, http://www.memoryprotectiondevices.com/datasheets/BC2AAPC-datasheet.pdf +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_MPD_BC12AAPC_2xAA +2xAA cell battery holder, Memory Protection Devices P/N BC12AAPC, http://www.memoryprotectiondevices.com/datasheets/BC12AAPC-datasheet.pdf +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_MPD_BC2003_1x2032 +http://www.memoryprotectiondevices.com/datasheets/BC-2003-datasheet.pdf +BC2003 CR2032 2032 Battery Holder +0 +3 +2 +Battery +BatteryHolder_MPD_BH-18650-PC2 +18650 Battery Holder (http://www.memoryprotectiondevices.com/datasheets/BK-18650-PC2-datasheet.pdf) +18650 Battery Holder +0 +2 +2 +Battery +BatteryHolder_Seiko_MS621F +Seiko MS621F, https://www.sii.co.jp/en/me/files/2014/02/file_EXTENDED_PRDCT_SPEC_75_FILE_11.jpg +Seiko MS621F +0 +2 +2 +Battery +BatteryHolder_TruPower_BH-331P_3xAA +Keystone Battery Holder BH-331P Battery Type 3xAA (Script generated with StandardBox.py) (Keystone Battery Holder BH-331P Battery Type 3xAA) +Battery Holder BH-331P Battery Type 3xAA +0 +2 +2 +Battery +Battery_CR1225 +CR1225 battery +battery CR1225 coin cell +0 +0 +0 +Battery +Battery_Panasonic_CR1025-VSK_Vertical_CircularHoles +Panasonic CR-1025/VSK battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-1025 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR1220-VCN_Vertical_CircularHoles +Panasonic CR-1220/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-1220 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR1632-V1AN_Vertical_CircularHoles +Panasonic CR-1632-V1AN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-1632 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2025-V1AK_Vertical_CircularHoles +Panasonic CR-2025/V1AK battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2025 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2032-VS1N_Vertical_CircularHoles +Panasonic CR-2032/VS1N battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2032 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2354-VCN_Vertical_CircularHoles +Panasonic CR-2354/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2354/VCN coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2450-VAN_Vertical_CircularHoles +Panasonic CR-2450/VAN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2450 coin cell +0 +2 +2 +Battery +Battery_Panasonic_CR2477-VCN_Vertical_CircularHoles +Panasonic CR-2477/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-2477 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR3032-VCN_Vertical_CircularHoles +Panasonic CR-3032/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.pdf +battery CR-3032 coin cell vertical +0 +2 +2 +Button_Switch_Keyboard +SK6812MINI_and_cherry_Silk_GND + + +0 +12 +6 +Button_Switch_Keyboard +SW_Cherry_MX_1.00u_PCB +Cherry MX keyswitch, 1.00u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.00u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.00u_Plate +Cherry MX keyswitch, 1.00u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.00u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.25u_PCB +Cherry MX keyswitch, 1.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.25u_Plate +Cherry MX keyswitch, 1.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.50u_PCB +Cherry MX keyswitch, 1.50u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.50u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.50u_Plate +Cherry MX keyswitch, 1.50u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.50u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.75u_PCB +Cherry MX keyswitch, 1.75u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.75u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.75u_Plate +Cherry MX keyswitch, 1.75u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.75u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_PCB +Cherry MX keyswitch, 2.00u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Plate +Cherry MX keyswitch, 2.00u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Vertical_PCB +Cherry MX keyswitch, 2.00u, vertical, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u vertical PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Vertical_Plate +Cherry MX keyswitch, 2.00u, vertical, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u vertical plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.25u_PCB +Cherry MX keyswitch, 2.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.25u_Plate +Cherry MX keyswitch, 2.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.75u_PCB +Cherry MX keyswitch, 2.75u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.75u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.75u_Plate +Cherry MX keyswitch, 2.75u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.75u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_6.25u_PCB +Cherry MX keyswitch, 6.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 6.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_6.25u_Plate +Cherry MX keyswitch, 6.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 6.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_ISOEnter_PCB +Cherry MX keyswitch, ISO Enter, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch ISO enter PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_ISOEnter_Plate +Cherry MX keyswitch, ISO Enter, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch ISO enter plate +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.00u +Matias/ALPS keyswitch, 1.00u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.00u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.25u +Matias/ALPS keyswitch, 1.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.50u +Matias/ALPS keyswitch, 1.50u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.50u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.75u +Matias/ALPS keyswitch, 1.75u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.75u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.00u +Matias/ALPS keyswitch, 2.00u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.00u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.25u +Matias/ALPS keyswitch, 2.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.75u +Matias/ALPS keyswitch, 2.75u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.75u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_6.25u +Matias/ALPS keyswitch, 6.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 6.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_ISOEnter +Matias/ALPS keyswitch, ISO Enter, http://matias.ca/switches/ +Matias ALPS keyswitch ISO enter +0 +2 +2 +Button_Switch_SMD +Nidec_Copal_SH-7010A +4-bit rotary coded switch, J-hook, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_SMD +Nidec_Copal_SH-7010B +4-bit rotary coded switch, gull wing, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_SMD +Nidec_Copal_SH-7040B +4-bit rotary coded switch, gull wing, Gray code, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +5 +5 +Button_Switch_SMD +Panasonic_EVQPUJ_EVQPUA +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUJ EVQPUA +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUK_EVQPUB +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUK EVQPUB +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUL_EVQPUC +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUL EVQPUC +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUM_EVQPUD +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUM EVQPUD +0 +4 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 1x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W8.61mm_P2.54mm_LowProfile +SMD 1x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_9.78x4.72mm_W8.61mm_P2.54mm +SMD 1x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x4.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CHS-01A_W5.08mm_P1.27mm_JPin +SMD 1x-dip-switch SPST Copal_CHS-01A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CHS-01B_W7.62mm_P1.27mm +SMD 1x-dip-switch SPST Copal_CHS-01B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CVS-01xB_W5.9mm_P1mm +SMD 1x-dip-switch SPST Copal_CVS-01xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +6 +3 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Omron_A6S-110x_W8.9mm_P2.54mm +SMD 1x-dip-switch SPST Omron_A6S-110x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 2x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W8.61mm_P2.54mm_LowProfile +SMD 2x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_9.78x7.26mm_W8.61mm_P2.54mm +SMD 2x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x7.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CHS-02A_W5.08mm_P1.27mm_JPin +SMD 2x-dip-switch SPST Copal_CHS-02A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CHS-02B_W7.62mm_P1.27mm +SMD 2x-dip-switch SPST Copal_CHS-02B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CVS-02xB_W5.9mm_P1mm +SMD 2x-dip-switch SPST Copal_CVS-02xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +8 +5 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_KingTek_DSHP02TJ_W5.25mm_P1.27mm_JPin +SMD 2x-dip-switch SPST KingTek_DSHP02TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_KingTek_DSHP02TS_W7.62mm_P1.27mm +SMD 2x-dip-switch SPST KingTek_DSHP02TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Omron_A6H-2101_W6.15mm_P1.27mm +SMD 2x-dip-switch SPST Omron_A6H-2101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Omron_A6S-210x_W8.9mm_P2.54mm +SMD 2x-dip-switch SPST Omron_A6S-210x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 3x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W8.61mm_P2.54mm_LowProfile +SMD 3x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_9.78x9.8mm_W8.61mm_P2.54mm +SMD 3x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x9.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_Copal_CVS-03xB_W5.9mm_P1mm +SMD 3x-dip-switch SPST Copal_CVS-03xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +10 +7 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_KingTek_DSHP03TJ_W5.25mm_P1.27mm_JPin +SMD 3x-dip-switch SPST KingTek_DSHP03TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_KingTek_DSHP03TS_W7.62mm_P1.27mm +SMD 3x-dip-switch SPST KingTek_DSHP03TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_Omron_A6S-310x_W8.9mm_P2.54mm +SMD 3x-dip-switch SPST Omron_A6S-310x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 4x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W8.61mm_P2.54mm_LowProfile +SMD 4x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_9.78x12.34mm_W8.61mm_P2.54mm +SMD 4x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x12.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CHS-04A_W5.08mm_P1.27mm_JPin +SMD 4x-dip-switch SPST Copal_CHS-04A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CHS-04B_W7.62mm_P1.27mm +SMD 4x-dip-switch SPST Copal_CHS-04B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CVS-04xB_W5.9mm_P1mm +SMD 4x-dip-switch SPST Copal_CVS-04xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +12 +9 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_KingTek_DSHP04TJ_W5.25mm_P1.27mm_JPin +SMD 4x-dip-switch SPST KingTek_DSHP04TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_KingTek_DSHP04TS_W7.62mm_P1.27mm +SMD 4x-dip-switch SPST KingTek_DSHP04TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Omron_A6H-4101_W6.15mm_P1.27mm +SMD 4x-dip-switch SPST Omron_A6H-4101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Omron_A6S-410x_W8.9mm_P2.54mm +SMD 4x-dip-switch SPST Omron_A6S-410x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 5x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W8.61mm_P2.54mm_LowProfile +SMD 5x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_9.78x14.88mm_W8.61mm_P2.54mm +SMD 5x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x14.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_KingTek_DSHP05TJ_W5.25mm_P1.27mm_JPin +SMD 5x-dip-switch SPST KingTek_DSHP05TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_KingTek_DSHP05TS_W7.62mm_P1.27mm +SMD 5x-dip-switch SPST KingTek_DSHP05TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_Omron_A6S-510x_W8.9mm_P2.54mm +SMD 5x-dip-switch SPST Omron_A6S-510x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 6x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W8.61mm_P2.54mm_LowProfile +SMD 6x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_9.78x17.42mm_W8.61mm_P2.54mm +SMD 6x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x17.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Copal_CHS-06A_W5.08mm_P1.27mm_JPin +SMD 6x-dip-switch SPST Copal_CHS-06A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Copal_CHS-06B_W7.62mm_P1.27mm +SMD 6x-dip-switch SPST Copal_CHS-06B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_KingTek_DSHP06TJ_W5.25mm_P1.27mm_JPin +SMD 6x-dip-switch SPST KingTek_DSHP06TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_KingTek_DSHP06TS_W7.62mm_P1.27mm +SMD 6x-dip-switch SPST KingTek_DSHP06TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Omron_A6H-6101_W6.15mm_P1.27mm +SMD 6x-dip-switch SPST Omron_A6H-6101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Omron_A6S-610x_W8.9mm_P2.54mm +SMD 6x-dip-switch SPST Omron_A6S-610x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 7x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W8.61mm_P2.54mm_LowProfile +SMD 7x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_9.78x19.96mm_W8.61mm_P2.54mm +SMD 7x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x19.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_KingTek_DSHP07TJ_W5.25mm_P1.27mm_JPin +SMD 7x-dip-switch SPST KingTek_DSHP07TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_KingTek_DSHP07TS_W7.62mm_P1.27mm +SMD 7x-dip-switch SPST KingTek_DSHP07TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_Omron_A6S-710x_W8.9mm_P2.54mm +SMD 7x-dip-switch SPST Omron_A6S-710x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 8x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W8.61mm_P2.54mm_LowProfile +SMD 8x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_9.78x22.5mm_W8.61mm_P2.54mm +SMD 8x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x22.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CHS-08A_W5.08mm_P1.27mm_JPin +SMD 8x-dip-switch SPST Copal_CHS-08A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CHS-08B_W7.62mm_P1.27mm +SMD 8x-dip-switch SPST Copal_CHS-08B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CVS-08xB_W5.9mm_P1mm +SMD 8x-dip-switch SPST Copal_CVS-08xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +20 +17 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_KingTek_DSHP08TJ_W5.25mm_P1.27mm_JPin +SMD 8x-dip-switch SPST KingTek_DSHP08TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_KingTek_DSHP08TS_W7.62mm_P1.27mm +SMD 8x-dip-switch SPST KingTek_DSHP08TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Omron_A6H-8101_W6.15mm_P1.27mm +SMD 8x-dip-switch SPST Omron_A6H-8101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Omron_A6S-810x_W8.9mm_P2.54mm +SMD 8x-dip-switch SPST Omron_A6S-810x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 9x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W8.61mm_P2.54mm_LowProfile +SMD 9x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_9.78x25.04mm_W8.61mm_P2.54mm +SMD 9x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x25.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_KingTek_DSHP09TJ_W5.25mm_P1.27mm_JPin +SMD 9x-dip-switch SPST KingTek_DSHP09TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_KingTek_DSHP09TS_W7.62mm_P1.27mm +SMD 9x-dip-switch SPST KingTek_DSHP09TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_Omron_A6S-910x_W8.9mm_P2.54mm +SMD 9x-dip-switch SPST Omron_A6S-910x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 10x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W8.61mm_P2.54mm_LowProfile +SMD 10x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_9.78x27.58mm_W8.61mm_P2.54mm +SMD 10x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x27.58mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Copal_CHS-10A_W5.08mm_P1.27mm_JPin +SMD 10x-dip-switch SPST Copal_CHS-10A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Copal_CHS-10B_W7.62mm_P1.27mm +SMD 10x-dip-switch SPST Copal_CHS-10B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_KingTek_DSHP10TJ_W5.25mm_P1.27mm_JPin +SMD 10x-dip-switch SPST KingTek_DSHP10TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_KingTek_DSHP10TS_W7.62mm_P1.27mm +SMD 10x-dip-switch SPST KingTek_DSHP10TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Omron_A6H-10101_W6.15mm_P1.27mm +SMD 10x-dip-switch SPST Omron_A6H-10101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Omron_A6S-1010x_W8.9mm_P2.54mm +SMD 10x-dip-switch SPST Omron_A6S-1010x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 11x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W8.61mm_P2.54mm_LowProfile +SMD 11x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_9.78x30.12mm_W8.61mm_P2.54mm +SMD 11x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x30.12mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 12x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +24 +24 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W8.61mm_P2.54mm_LowProfile +SMD 12x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +24 +24 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_9.78x32.66mm_W8.61mm_P2.54mm +SMD 12x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x32.66mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +24 +24 +Button_Switch_SMD +SW_DPDT_CK_JS202011JCQN +Sub-miniature slide switch, vertical, SMT J bend https://dznh3ojzb2azq.cloudfront.net/products/Slide/JS/documents/datasheet.pdf +switch DPDT SMT +0 +6 +6 +Button_Switch_SMD +SW_MEC_5GSH9 +MEC 5G single pole normally-open tactile switch +switch normally-open pushbutton push-button +0 +4 +4 +Button_Switch_SMD +SW_Push_1P1T-MP_NO_Horizontal_Alps_SKRTLAE010 +Side push button (https://www.alps.com/prod/info/E/PDF/Tact/SurfaceMount/SKRT/SKRT.pdf) +push horizontal SPST 1P1T +0 +5 +3 +Button_Switch_SMD +SW_Push_1P1T-SH_NO_CK_KMR2xxG +CK components KMR2 tactile switch with ground pin http://www.ckswitches.com/media/1479/kmr2.pdf +tactile switch kmr2 +0 +5 +3 +Button_Switch_SMD +SW_Push_1P1T_NO_6x6mm_H9.5mm +tactile push button, 6x6mm e.g. PTS645xx series, height=9.5mm +tact sw push 6mm smd +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KMR2 +CK components KMR2 tactile switch http://www.ckswitches.com/media/1479/kmr2.pdf +tactile switch kmr2 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KSC6xxJ +CK components KSC6 tactile switch https://www.ckswitches.com/media/1972/ksc6.pdf +tactile switch ksc6 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KSC7xxJ +CK components KSC7 tactile switch https://www.ckswitches.com/media/1973/ksc7.pdf +tactile switch ksc7 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_PTS125Sx43PSMTR +C&K Switches 1P1T SMD PTS125 Series 12mm Tact Switch with Pegs, https://www.ckswitches.com/media/1462/pts125.pdf +Button Tactile Switch SPST 1P1T +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_Vertical_Wuerth_434133025816 +https://katalog.we-online.com/em/datasheet/434133025816.pdf +tactile switch Wurth Wuerth +0 +4 +2 +Button_Switch_SMD +SW_Push_SPST_NO_Alps_SKRK +http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKRK/SKRKAHE020.html +SMD SMT button +0 +2 +2 +Button_Switch_SMD +SW_SP3T_PCM13 +Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf + +0 +8 +4 +Button_Switch_SMD +SW_SPDT_CK-JS102011SAQN +Sub-miniature slide switch, right-angle, http://www.ckswitches.com/media/1422/js.pdf +switch spdt +0 +3 +3 +Button_Switch_SMD +SW_SPDT_PCM12 +Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf + +0 +7 +3 +Button_Switch_SMD +SW_SPST_B3S-1000 +Surface Mount Tactile Switch for High-Density Packaging +Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3S-1100 +Surface Mount Tactile Switch for High-Density Packaging with Ground Terminal +Tactile Switch +0 +5 +3 +Button_Switch_SMD +SW_SPST_B3SL-1002P +Middle Stroke Tactile Switch, B3SL +Middle Stroke Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3SL-1022P +Middle Stroke Tactile Switch, B3SL +Middle Stroke Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3U-1000P +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, without Ground Terminal, without Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-1000P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, without Ground Terminal, with Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-1100P +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, with Ground Terminal, without Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-1100P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, with Ground Terminal, with Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-3000P +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, without Ground Terminal, without Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-3000P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, without Ground Terminal, with Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-3100P +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, with Ground Terminal, without Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-3100P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, with Ground Terminal, with Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_CK_KXT3 +https://www.ckswitches.com/media/1465/kxt3.pdf +Switch SPST KXT3 +0 +2 +2 +Button_Switch_SMD +SW_SPST_CK_RS282G05A3 +https://www.mouser.com/ds/2/60/RS-282G05A-SM_RT-1159762.pdf +SPST button tactile switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_EVPBF +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP0 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE28.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP2 +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP7A +Light Touch Switch,https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE20.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP7C +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQPE1 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE7.pdf + +0 +2 +2 +Button_Switch_SMD +SW_SPST_EVQQ2 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE28.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_FSMSM +http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=1437566-3&DocType=Customer+Drawing&DocLang=English +SPST button tactile switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_Omron_B3FS-100xP +Surface Mount Tactile Switch for High-Density Mounting, 3.1mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +4 +Button_Switch_SMD +SW_SPST_Omron_B3FS-101xP +Surface Mount Tactile Switch for High-Density Mounting, 4.3mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +4 +Button_Switch_SMD +SW_SPST_Omron_B3FS-105xP +Surface Mount Tactile Switch for High-Density Mounting, 7.3mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +4 +Button_Switch_SMD +SW_SPST_PTS645 +C&K Components SPST SMD PTS645 Series 6mm Tact Switch +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_PTS810 +C&K Components, PTS 810 Series, Microminiature SMT Top Actuated, http://www.ckswitches.com/media/1476/pts810.pdf +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_Panasonic_EVQPL_3PL_5PL_PT_A08 +Light Touch Switch, http://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE3.pdf +SMD SMT SPST EVQPL EVQPT +0 +6 +3 +Button_Switch_SMD +SW_SPST_Panasonic_EVQPL_3PL_5PL_PT_A15 +Light Touch Switch, http://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE3.pdf +SMD SMT SPST EVQPL EVQPT +0 +6 +3 +Button_Switch_SMD +SW_SPST_REED_CT05-XXXX-G1 +Coto Technologies SPST Reed Switch CT05-XXXX-G1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT05-XXXX-J1 +Coto Technologies SPST Reed Switch CT05-XXXX-J1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G1 +Coto Technologies SPST Reed Switch CT10-XXXX-G1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G2 +Coto Technologies SPST Reed Switch CT10-XXXX-G2 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G4 +Coto Technologies SPST Reed Switch CT10-XXXX-G4 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_SKQG_WithStem +ALPS 5.2mm Square Low-profile Type (Surface Mount) SKQG Series, With stem, http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKQG/SKQGAFE010.html +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_SKQG_WithoutStem +ALPS 5.2mm Square Low-profile Type (Surface Mount) SKQG Series, Without stem, http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKQG/SKQGAEE010.html +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305A +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305B +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305C +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3342 +Low-profile SMD Tactile Switch, https://www.e-switch.com/system/asset/product_line/data_sheet/165/TL3342.pdf +SPST Tactile Switch +0 +4 +2 +Button_Switch_THT +KSA_Tactile_SPST +KSA http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SWITCH SMD KSA SW +0 +5 +5 +Button_Switch_THT +Nidec_Copal_SH-7010C +4-bit rotary coded switch, through-hole, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_THT +Push_E-Switch_KS01Q01 +E-Switch KS01Q01 http://spec_sheets.e-switch.com/specs/29-KS01Q01.pdf +Push Button +0 +4 +4 +Button_Switch_THT +SW_CW_GPTS203211B +SPST Off-On Pushbutton, 1A, 30V, CW Industries P/N GPTS203211B, http://switches-connectors-custom.cwind.com/Asset/GPTS203211BR2.pdf +SPST button switch Off-On +0 +2 +2 +Button_Switch_THT +SW_CuK_JS202011AQN_DPDT_Angled +CuK sub miniature slide switch, JS series, DPDT, right angle, http://www.ckswitches.com/media/1422/js.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_CuK_JS202011CQN_DPDT_Straight +CuK sub miniature slide switch, JS series, DPDT, right angle, http://www.ckswitches.com/media/1422/js.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_CuK_OS102011MA1QN1_SPDT_Angled +CuK miniature slide switch, OS series, SPDT, right angle, http://www.ckswitches.com/media/1428/os.pdf +switch SPDT +0 +5 +3 +Button_Switch_THT +SW_DIP_SPSTx01_Piano_10.8x4.1mm_W7.62mm_P2.54mm +1x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x4.1mm +DIP Switch SPST Piano 7.62mm 300mil +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W7.62mm_P2.54mm_LowProfile +1x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx01_Slide_9.78x4.72mm_W7.62mm_P2.54mm +1x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x4.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx02_Piano_10.8x6.64mm_W7.62mm_P2.54mm +2x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x6.64mm +DIP Switch SPST Piano 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Piano_CTS_Series194-2MSTN_W7.62mm_P2.54mm +2x-dip-switch SPST CTS_Series194-2MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W7.62mm_P2.54mm_LowProfile +2x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Slide_9.78x7.26mm_W7.62mm_P2.54mm +2x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x7.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx03_Piano_10.8x9.18mm_W7.62mm_P2.54mm +3x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x9.18mm +DIP Switch SPST Piano 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Piano_CTS_Series194-3MSTN_W7.62mm_P2.54mm +3x-dip-switch SPST CTS_Series194-3MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W7.62mm_P2.54mm_LowProfile +3x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Slide_9.78x9.8mm_W7.62mm_P2.54mm +3x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x9.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx04_Piano_10.8x11.72mm_W7.62mm_P2.54mm +4x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x11.72mm +DIP Switch SPST Piano 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Piano_CTS_Series194-4MSTN_W7.62mm_P2.54mm +4x-dip-switch SPST CTS_Series194-4MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W7.62mm_P2.54mm_LowProfile +4x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Slide_9.78x12.34mm_W7.62mm_P2.54mm +4x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x12.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx05_Piano_10.8x14.26mm_W7.62mm_P2.54mm +5x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x14.26mm +DIP Switch SPST Piano 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Piano_CTS_Series194-5MSTN_W7.62mm_P2.54mm +5x-dip-switch SPST CTS_Series194-5MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W7.62mm_P2.54mm_LowProfile +5x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Slide_9.78x14.88mm_W7.62mm_P2.54mm +5x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x14.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx06_Piano_10.8x16.8mm_W7.62mm_P2.54mm +6x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x16.8mm +DIP Switch SPST Piano 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Piano_CTS_Series194-6MSTN_W7.62mm_P2.54mm +6x-dip-switch SPST CTS_Series194-6MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W7.62mm_P2.54mm_LowProfile +6x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Slide_9.78x17.42mm_W7.62mm_P2.54mm +6x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x17.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx07_Piano_10.8x19.34mm_W7.62mm_P2.54mm +7x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x19.34mm +DIP Switch SPST Piano 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Piano_CTS_Series194-7MSTN_W7.62mm_P2.54mm +7x-dip-switch SPST CTS_Series194-7MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W7.62mm_P2.54mm_LowProfile +7x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Slide_9.78x19.96mm_W7.62mm_P2.54mm +7x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x19.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx08_Piano_10.8x21.88mm_W7.62mm_P2.54mm +8x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x21.88mm +DIP Switch SPST Piano 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Piano_CTS_Series194-8MSTN_W7.62mm_P2.54mm +8x-dip-switch SPST CTS_Series194-8MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W7.62mm_P2.54mm_LowProfile +8x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Slide_9.78x22.5mm_W7.62mm_P2.54mm +8x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x22.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx09_Piano_10.8x24.42mm_W7.62mm_P2.54mm +9x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x24.42mm +DIP Switch SPST Piano 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Piano_CTS_Series194-9MSTN_W7.62mm_P2.54mm +9x-dip-switch SPST CTS_Series194-9MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W7.62mm_P2.54mm_LowProfile +9x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Slide_9.78x25.04mm_W7.62mm_P2.54mm +9x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x25.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx10_Piano_10.8x26.96mm_W7.62mm_P2.54mm +10x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x26.96mm +DIP Switch SPST Piano 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Piano_CTS_Series194-10MSTN_W7.62mm_P2.54mm +10x-dip-switch SPST CTS_Series194-10MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W7.62mm_P2.54mm_LowProfile +10x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Slide_9.78x27.58mm_W7.62mm_P2.54mm +10x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x27.58mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx11_Piano_10.8x29.5mm_W7.62mm_P2.54mm +11x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x29.5mm +DIP Switch SPST Piano 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Piano_CTS_Series194-11MSTN_W7.62mm_P2.54mm +11x-dip-switch SPST CTS_Series194-11MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W7.62mm_P2.54mm_LowProfile +11x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Slide_9.78x30.12mm_W7.62mm_P2.54mm +11x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x30.12mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx12_Piano_10.8x32.04mm_W7.62mm_P2.54mm +12x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x32.04mm +DIP Switch SPST Piano 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Piano_CTS_Series194-12MSTN_W7.62mm_P2.54mm +12x-dip-switch SPST CTS_Series194-12MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W7.62mm_P2.54mm_LowProfile +12x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Slide_9.78x32.66mm_W7.62mm_P2.54mm +12x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x32.66mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_E-Switch_EG1224_SPDT_Angled +E-Switch slide switch, EG series, SPDT, right angle, http://spec_sheets.e-switch.com/specs/P040042.pdf +switch SPDT +0 +7 +3 +Button_Switch_THT +SW_E-Switch_EG1271_DPDT +E-Switch sub miniature slide switch, EG series, DPDT, http://spec_sheets.e-switch.com/specs/P040047.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_E-Switch_EG2219_DPDT_Angled +E-Switch slide switch, EG series, DPDT, right angle, http://spec_sheets.e-switch.com/specs/P040170.pdf +switch DPDT +0 +10 +6 +Button_Switch_THT +SW_Lever_1P2T_NKK_GW12LxH +Switch, single pole double throw, right angle, http://www.nkkswitches.com/pdf/GW.pdf +switch single-pole double-throw spdt ON-ON horizontal +0 +5 +3 +Button_Switch_THT +SW_MEC_5GTH9 +MEC 5G single pole normally-open tactile switch https://cdn.sos.sk/productdata/80/f6/aabf7be6/5gth9358222.pdf +switch normally-open pushbutton push-button +0 +4 +2 +Button_Switch_THT +SW_NKK_BB15AH +https://www.nkkswitches.com/pdf/Bpushbuttons-1.pdf +Pushbutton Right-angle +0 +5 +3 +Button_Switch_THT +SW_NKK_G1xJP +Switch NKK G1xJP http://www.nkkswitches.com/pdf/gwillum.pdf +SWITCH TOGGLE ILLUM SPDT NKK +0 +6 +6 +Button_Switch_THT +SW_NKK_GW12LJP +Switch, single pole double throw, illuminated paddle, http://www.nkkswitches.com/pdf/gwillum.pdf +switch single-pole double-throw spdt ON-ON illuminated LED +0 +6 +6 +Button_Switch_THT +SW_PUSH-12mm +SW PUSH 12mm https://www.e-switch.com/system/asset/product_line/data_sheet/143/TL1100.pdf +tact sw push 12mm +0 +4 +2 +Button_Switch_THT +SW_PUSH-12mm_Wuerth-430476085716 +SW PUSH 12mm http://katalog.we-online.de/em/datasheet/430476085716.pdf +tact sw push 12mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm +https://www.omron.com/ecb/products/pdf/en-b3f.pdf +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H4.3mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=4.3mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H7.3mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=7.3mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H8.5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=8.5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H8mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=8mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H9.5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=9.5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H13mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=13mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_E-Switch_FS5700DP_DPDT +FS5700 series pushbutton footswitch, DPDT, https://www.e-switch.com/system/asset/product_line/data_sheet/226/FS5700.pdf +switch DPDT footswitch +0 +6 +6 +Button_Switch_THT +SW_PUSH_LCD_E3_SAxxxx +Switch with LCD screen E3 SAxxxx +switch normally-open pushbutton push-button LCD +0 +6 +6 +Button_Switch_THT +SW_PUSH_LCD_E3_SAxxxx_SocketPins +Switch with LCD screen E3 SAxxxx +switch normally-open pushbutton push-button LCD +0 +6 +6 +Button_Switch_THT +SW_Push_1P1T_NO_LED_E-Switch_TL1250 +illuminated right angle tact switch https://www.e-switch.com/system/asset/product_line/data_sheet/148/TL1250.pdf +led push switch right angle +0 +6 +4 +Button_Switch_THT +SW_Push_1P2T_Vertical_E-Switch_800UDP8P1A1M6 + right angle SPDT push button https://www.e-switch.com/system/asset/product_line/data_sheet/210/800U.pdf +IP67 ultra-miniture horizontal +0 +5 +3 +Button_Switch_THT +SW_Push_2P2T_Vertical_E-Switch_800UDP8P1A1M6 + right angle DPDT push button https://www.e-switch.com/system/asset/product_line/data_sheet/210/800U.pdf +IP67 ultra-miniture horizontal +0 +8 +6 +Button_Switch_THT +SW_Slide_1P2T_CK_OS102011MS2Q +CuK miniature slide switch, OS series, SPDT, https://www.ckswitches.com/media/1428/os.pdf +switch SPDT +0 +5 +3 +Button_Switch_THT +SW_TH_Tactile_Omron_B3F-10xx +SW_TH_Tactile_Omron_B3F-10xx_https://www.omron.com/ecb/products/pdf/en-b3f.pdf +Omron B3F-10xx +0 +4 +4 +Button_Switch_THT +SW_Tactile_SKHH_Angled +tactile switch 6mm ALPS SKHH right angle http://www.alps.com/prod/info/E/HTML/Tact/SnapIn/SKHH/SKHHLUA010.html +tactile switch 6mm ALPS SKHH right angle +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx31-2LFS +tactile switch SPST right angle, PTS645VL31-2 LFS +tactile switch SPST angled PTS645VL31-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx39-2LFS +tactile switch SPST right angle, PTS645VL39-2 LFS +tactile switch SPST angled PTS645VL39-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx58-2LFS +tactile switch SPST right angle, PTS645VL58-2 LFS +tactile switch SPST angled PTS645VL58-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx83-2LFS +tactile switch SPST right angle, PTS645VL83-2 LFS +tactile switch SPST angled PTS645VL83-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_Straight_KSA0Axx1LFTR +SW PUSH SMALL http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SW PUSH SMALL Tactile C&K +0 +4 +2 +Button_Switch_THT +SW_Tactile_Straight_KSL0Axx1LFTR +SW PUSH SMALL http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SW PUSH SMALL Tactile C&K +0 +4 +2 +Buzzer_Beeper +Buzzer_12x9.5RM7.6 +Generic Buzzer, D12mm height 9.5mm with RM7.6mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_15x7.5RM7.6 +Generic Buzzer, D15mm height 7.5mm with RM7.6mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_CUI_CPT-9019S-SMT +https://www.cui.com/product/resource/cpt-9019s-smt.pdf +buzzer piezo +0 +2 +2 +Buzzer_Beeper +Buzzer_D14mm_H7mm_P10mm +Generic Buzzer, D14mm height 7mm with pitch 10mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_Mallory_AST1109MLTRQ +Mallory low-profile piezo buzzer, https://www.mspindy.com/specifications/AST1109MLTRQ.pdf +buzzer piezo +0 +2 +2 +Buzzer_Beeper +Buzzer_Murata_PKMCS0909E4000-R1 +Murata Buzzer http://www.murata.com/en-us/api/pdfdownloadapi?cate=&partno=PKMCS0909E4000-R1 +Murata Buzzer Beeper +0 +2 +2 +Buzzer_Beeper +Buzzer_TDK_PS1240P02BT_D12.2mm_H6.5mm +Buzzer, D12.2mm height 6.5mm, https://product.tdk.com/info/en/catalog/datasheets/piezoelectronic_buzzer_ps_en.pdf +buzzer +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_CUI_CMT-8504-100-SMT +magnetic transducer buzzer, 5V, SPL of 100 dB at 10 cm, https://www.cuidevices.com/product/resource/pdf/cmt-8504-100-smt-tr.pdf +CMT 8504 +0 +4 +4 +Buzzer_Beeper +MagneticBuzzer_CUI_CST-931RP-A +CST-931RP-A, http://www.cui.com/product/resource/cst-931rp-a.pdf +CST-931RP-A +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_Kingstate_KCG0601 +Buzzer, Elektromagnetic Beeper, Summer, +Kingstate KCG0601 +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_Kobitone_254-EMB84Q-RO +MagneticBuzzer Kobitone 254-EMB84Q-RO https://www.mouser.es/datasheet/2/209/KT-400385-1171904.pdf +MagneticBuzzer Kobitone 254-EMB84Q-RO +0 +3 +3 +Buzzer_Beeper +MagneticBuzzer_PUI_AT-0927-TT-6-R +Buzzer Magnetic 9mm AT-0927-TT-6-R, http://www.puiaudio.com/pdf/AT-0927-TT-6-R.pdf +Buzzer Magnetic 9mm AT-0927-TT-6-R +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABI-009-RC +Buzzer, Elektromagnetic Beeper, Summer, 6V-DC, +Pro Signal ABI-009-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABI-010-RC +Buzzer, Elektromagnetic Beeper, Summer, 12V-DC, +Pro Signal ABI-010-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABT-410-RC +Buzzer, Elektromagnetic Beeper, Summer, 1,5V-DC, +Pro Signal ABT-410-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProjectsUnlimited_AI-4228-TWT-R +Buzzer, Elektromagnetic Beeper, Summer, 3-28V-DC, https://www.kynix.com/uploadfiles/pdf/AI-4228-TWT-R.pdf +Projects Unlimited AI-4228-TWT-R +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_StarMicronics_HMB-06_HMB-12 +Buzzer, Elektromagnetic Beeper, Summer, +Star Micronics HMB-06 HMB-12 +0 +2 +2 +Buzzer_Beeper +PUIAudio_SMT_0825_S_4_R +SMD 8540, http://www.puiaudio.com/product-detail.aspx?partnumber=SMT-0825-S-4-R +SMD 8540 +0 +4 +4 +Buzzer_Beeper +Speaker_CUI_CMR-1206S-67 +Speaker, 30mW, 300-7000Hz, IP67 face, 12x6x2,25mm, https://www.cuidevices.com/product/resource/cmr-12062s-67.pdf +speaker CUI +0 +2 +2 +Calibration_Scale +Gauge_10mm_Type1_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 1, +Gauge Massstab 10mm CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type1_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 1, +Gauge Massstab 10mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type2_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 2, +Gauge Massstab 10mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type2_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 2, +Gauge Massstab 10mm SilkScreenTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type3_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 3, +Gauge Massstab 10mm CopperTop Type 3 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type3_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 3, +Gauge Massstab 10mm SilkScreenTop Type 3 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type4_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 4, +Gauge Massstab 10mm CopperTop Type 4 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type4_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 4, +Gauge Massstab 10mm SilkScreenTop Type 4 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type5_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 5, +Gauge Massstab 10mm CopperTop Type 5 +0 +0 +0 +Calibration_Scale +Gauge_10mm_Type5_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 5, +Gauge Massstab 10mm SilkScreenTop Type 5 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type1_CopperTop +Gauge, Massstab, 50mm, CopperTop, Type 1, +Gauge Massstab 50mm CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type1_SilkScreenTop +Gauge, Massstab, 50mm, SilkScreenTop, Type 1, +Gauge Massstab 50mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type2_CopperTop +Gauge, Massstab, 50mm, CopperTop, Type 2, +Gauge Massstab 50mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_50mm_Type2_SilkScreenTop +Gauge, Massstab, 50mm, SilkScreenTop, Type 2, +Gauge Massstab 50mm SilkScreenTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Grid_Type1_CopperTop +Gauge, Massstab, 100mm, Gitter, Grid, CopperTop, Type 1, +Gauge Massstab 100mm Gitter Grid CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type1_CopperTop +Gauge, Massstab, 100mm, CopperTop, Type 1, +Gauge Massstab 100mm CopperTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type1_SilkScreenTop +Gauge, Massstab, 100mm, SilkScreenTop, Type 1, +Gauge Massstab 100mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type2_CopperTop +Gauge, Massstab, 100mm, CopperTop, Type 2, +Gauge Massstab 100mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type2_SilkScreenTop +Gauge, Massstab, 100mm, SilkScreenTop, Type 2, +Gauge Massstab 100mm SilkScreenTop Type 2 +0 +0 +0 +Capacitor_SMD +CP_Elec_3x5.3 +SMT capacitor, aluminium electrolytic, 3x5.3, Cornell Dubilier Electronics +Capacitor Electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_3x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 3.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x3 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.3 +SMD capacitor, aluminum electrolytic, Vishay, 4.0x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.4 +SMD capacitor, aluminum electrolytic, Panasonic A5 / Nichicon, 4.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 4.0x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.8 +SMD capacitor, aluminum electrolytic, Panasonic, 4.0x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x3 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x3.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x4.4 +SMD capacitor, aluminum electrolytic, Panasonic B45, 5.0x4.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.3 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 5.0x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.8 +SMD capacitor, aluminum electrolytic, Panasonic, 5.0x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.9 +SMD capacitor, aluminum electrolytic, Panasonic B6, 5.0x5.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x3 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x3.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x4.9 +SMD capacitor, aluminum electrolytic, Panasonic C5, 6.3x4.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.2 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 6.3x5.2mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.3 +SMD capacitor, aluminum electrolytic, Cornell Dubilier, 6.3x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.4 +SMD capacitor, aluminum electrolytic, Panasonic C55, 6.3x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.4_Nichicon +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 6.3x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.8 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.9 +SMD capacitor, aluminum electrolytic, Panasonic C6, 6.3x5.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x7.7 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x7.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x9.9 +SMD capacitor, aluminum electrolytic, Panasonic C10, 6.3x9.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.2 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x6.2mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.5 +SMD capacitor, aluminum electrolytic, Rubycon, 8.0x6.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 8.0x6.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.9 +SMD capacitor, aluminum electrolytic, Panasonic E7, 8.0x6.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x10 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x10mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x10.5 +SMD capacitor, aluminum electrolytic, Vishay 0810, 8.0x10.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x11.9 +SMD capacitor, aluminum electrolytic, Panasonic E12, 8.0x11.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x7.7 +SMD capacitor, aluminum electrolytic, Nichicon, 10.0x7.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x7.9 +SMD capacitor, aluminum electrolytic, Panasonic F8, 10.0x7.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x10 +SMD capacitor, aluminum electrolytic, Nichicon, 10.0x10.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x10.5 +SMD capacitor, aluminum electrolytic, Vishay 1010, 10.0x10.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x12.5 +SMD capacitor, aluminum electrolytic, Vishay 1012, 10.0x12.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x12.6 +SMD capacitor, aluminum electrolytic, Panasonic F12, 10.0x12.6mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x14.3 +SMD capacitor, aluminum electrolytic, Vishay 1014, 10.0x14.3mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_16x17.5 +SMD capacitor, aluminum electrolytic, Vishay 1616, 16.0x17.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_16x22 +SMD capacitor, aluminum electrolytic, Vishay 1621, 16.0x22.0mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_18x17.5 +SMD capacitor, aluminum electrolytic, Vishay 1816, 18.0x17.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_18x22 +SMD capacitor, aluminum electrolytic, Vishay 1821, 18.0x22.0mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +C_0201_0603Metric +Capacitor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +capacitor +0 +4 +2 +Capacitor_SMD +C_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Capacitor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +4 +2 +Capacitor_SMD +C_0402_1005Metric +Capacitor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0402_1005Metric_Pad0.74x0.62mm_HandSolder +Capacitor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0504_1310Metric +Capacitor SMD 0504 (1310 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0504_1310Metric_Pad0.83x1.28mm_HandSolder +Capacitor SMD 0504 (1310 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0603_1608Metric +Capacitor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0603_1608Metric_Pad1.08x0.95mm_HandSolder +Capacitor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0805_2012Metric +Capacitor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf, https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0805_2012Metric_Pad1.18x1.45mm_HandSolder +Capacitor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf, https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_01005_0402Metric +Capacitor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +capacitor +0 +4 +2 +Capacitor_SMD +C_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Capacitor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +4 +2 +Capacitor_SMD +C_1206_3216Metric +Capacitor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1206_3216Metric_Pad1.33x1.80mm_HandSolder +Capacitor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1210_3225Metric +Capacitor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1210_3225Metric_Pad1.33x2.70mm_HandSolder +Capacitor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1812_4532Metric +Capacitor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1812_4532Metric_Pad1.57x3.40mm_HandSolder +Capacitor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1825_4564Metric +Capacitor SMD 1825 (4564 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1825_4564Metric_Pad1.57x6.80mm_HandSolder +Capacitor SMD 1825 (4564 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_2220_5650Metric +Capacitor SMD 2220 (5650 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_2220_5650Metric_Pad1.97x5.40mm_HandSolder +Capacitor SMD 2220 (5650 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_2225_5664Metric +Capacitor SMD 2225 (5664 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_2225_5664Metric_Pad1.80x6.60mm_HandSolder +Capacitor SMD 2225 (5664 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_3640_9110Metric +Capacitor SMD 3640 (9110 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_3640_9110Metric_Pad2.10x10.45mm_HandSolder +Capacitor SMD 3640 (9110 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_Elec_3x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 3.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_4x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 4.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_4x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 4.0x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_5x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 5.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_5x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 5.0x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x7.7 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x7.7mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x6.2 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x6.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x10.2 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x10.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_10x10.2 +SMD capacitor, aluminum electrolytic nonpolar, 10.0x10.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZB4-A +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZB4 TZB4-A +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZB4-B +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZB4 TZB4-A +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZC3 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZC3 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZR1 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZR1 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZW4 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZW4 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZY2 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZY2 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Sprague-Goodman_SGC3 +trimmer capacitor SMD horizontal, http://media.wix.com/ugd/d86717_38d9821e12823a7aa9cef38c6c2a73cc.pdf + Sprague Goodman SGC3 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JN +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JN +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JQ +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JQ +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JR +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JR +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JV +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JV +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JZ +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JR +0 +2 +2 +Capacitor_THT +CP_Axial_L10.0mm_D4.5mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=10*4.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 10mm diameter 4.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L10.0mm_D6.0mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=10*6mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 10mm diameter 6mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D5.0mm_P18.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=18mm, , length*diameter=11*5mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 18mm length 11mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D6.0mm_P18.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=18mm, , length*diameter=11*6mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 18mm length 11mm diameter 6mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D8.0mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=11*8mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 11mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D6.5mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*6.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 6.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D8.0mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*8mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D10.0mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L20.0mm_D10.0mm_P26.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=26mm, , length*diameter=20*10mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 26mm length 20mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L20.0mm_D13.0mm_P26.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=26mm, , length*diameter=20*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 26mm length 20mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L21.0mm_D8.0mm_P28.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=28mm, , length*diameter=21*8mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 28mm length 21mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L25.0mm_D10.0mm_P30.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=30mm, , length*diameter=25*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 30mm length 25mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L26.5mm_D20.0mm_P33.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=33mm, , length*diameter=26.5*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 33mm length 26.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D10.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*10mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D13.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D16.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*16mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D20.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D10.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D12.5mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*12.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D15.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*15mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 15mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D18.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*18mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L34.5mm_D20.0mm_P41.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=41mm, , length*diameter=34.5*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 41mm length 34.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D13.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D16.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*16mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D20.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L38.0mm_D18.0mm_P44.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=44mm, , length*diameter=38*18mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 44mm length 38mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L38.0mm_D21.0mm_P44.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=44mm, , length*diameter=38*21mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 44mm length 38mm diameter 21mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L40.0mm_D16.0mm_P48.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=48mm, , length*diameter=40*16mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 48mm length 40mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D23.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D26.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D29.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D32.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D35.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.5mm_D20.0mm_P49.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=49mm, , length*diameter=42.5*20mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 49mm length 42.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L46.0mm_D20.0mm_P52.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=52mm, , length*diameter=46*20mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 52mm length 46mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D23.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D26.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D29.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D32.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D35.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D23.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D26.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D29.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D32.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D35.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D23.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D26.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D29.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D32.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D35.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D23.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D26.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D29.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D32.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D35.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D4.0mm_P1.50mm +CP, Radial series, Radial, pin pitch=1.50mm, , diameter=4mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 1.50mm diameter 4mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D4.0mm_P2.00mm +CP, Radial series, Radial, pin pitch=2.00mm, , diameter=4mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.00mm diameter 4mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D5.0mm_P2.00mm +CP, Radial series, Radial, pin pitch=2.00mm, , diameter=5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.00mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D5.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D6.3mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=6.3mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 6.3mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D7.5mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=7.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 7.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P3.50mm +CP, Radial series, Radial, pin pitch=3.50mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.50mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P3.80mm +CP, Radial series, Radial, pin pitch=3.80mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.80mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P2.50mm_P5.00mm +CP, Radial series, Radial, pin pitch=2.50mm 5.00mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm 5.00mm diameter 10mm Electrolytic Capacitor +0 +4 +2 +Capacitor_THT +CP_Radial_D10.0mm_P3.50mm +CP, Radial series, Radial, pin pitch=3.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P3.80mm +CP, Radial series, Radial, pin pitch=3.80mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.80mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P5.00mm_P7.50mm +CP, Radial series, Radial, pin pitch=5.00mm 7.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm 7.50mm diameter 10mm Electrolytic Capacitor +0 +4 +2 +Capacitor_THT +CP_Radial_D10.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D14.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=14mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 14mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D14.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=14mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 14mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D16.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=16mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D17.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=17mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 17mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D18.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=18mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D22.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=22mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 22mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D22.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=22mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 22mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D24.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=24mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 24mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D24.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=24mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 24mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D25.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=25mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 25mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D25.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=25mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 25mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D26.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=26mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 26mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D26.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=26mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D30.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=30mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 30mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D30.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=30mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 30mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D35.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=35mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 35mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D35.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=35mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 35mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D40.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=40mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 40mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D40.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=40mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 40mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D4.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=4.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 4.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D4.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=4.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 4.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=5.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 5.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=5.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 5.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=5.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 5.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=5.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 5.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D6.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=6.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 6.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D6.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=6.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 6.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D7.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=7.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 7.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D7.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=7.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 7.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D8.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=8.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 8.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D8.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=8.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 8.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D9.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=9.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 9.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D9.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=9.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 9.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D10.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=10.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 10.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D10.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=10.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 10.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P7.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=7.5mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 7.5mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P10.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=10mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 10mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P12.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=12.5mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 12.5mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 15mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P7.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=7.5mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 7.5mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P10.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=10mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 10mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P12.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=12.5mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 12.5mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 15mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D6.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D6.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D7.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D7.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D8.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*8.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 8.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D8.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*8.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 8.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D9.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D9.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D10.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D10.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D6.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=17*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 17mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D6.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=17*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 17mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D7.0mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=17*7.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 17mm diameter 7.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D7.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=17*7.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 17mm diameter 7.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D7.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D8.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*8.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 8.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D9.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*9mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 9mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D9.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L22.0mm_D9.5mm_P27.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=27.5mm, , length*diameter=22*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 27.5mm length 22mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L22.0mm_D10.5mm_P27.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=27.5mm, , length*diameter=22*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 27.5mm length 22mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Disc_D3.0mm_W1.6mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.0*1.6mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.0mm width 1.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.0mm_W2.0mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3*2mm^2, Capacitor +C Disc series Radial pin pitch 2.50mm diameter 3mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.4mm_W2.1mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.4*2.1mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.4mm width 2.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.8mm_W2.6mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.8*2.6mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.8mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D4.3mm_W1.9mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=4.3*1.9mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 4.3mm width 1.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D4.7mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=4.7*2.5mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 4.7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.0mm_W2.5mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=5*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 2.50mm diameter 5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=5*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.1mm_W3.2mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=5.1*3.2mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 5.1mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D6.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=6*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 6mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D6.0mm_W4.4mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=6*4.4mm^2, Capacitor +C Disc series Radial pin pitch 5.00mm diameter 6mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*2.5mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W4.4mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*4.4mm^2, Capacitor +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=8*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 8mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=9*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 9mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=10*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 10mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.0mm_W4.4mm_P7.75mm +C, Disc series, Radial, pin pitch=7.75mm, , diameter*width=12*4.4mm^2, Capacitor +C Disc series Radial pin pitch 7.75mm diameter 12mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=12.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 12.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=12.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 12.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D14.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=14.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 14.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D14.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=14.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 14.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D16.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=16.0*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 16.0mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D16.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=16.0*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 16.0mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D4.0mm_H5.0mm_P1.50mm +C, Radial series, Radial, pin pitch=1.50mm, diameter=4mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 1.50mm diameter 4mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D4.0mm_H7.0mm_P1.50mm +C, Radial series, Radial, pin pitch=1.50mm, diameter=4mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 1.50mm diameter 4mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H5.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H7.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H11.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=11mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 11mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H5.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H7.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H11.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=11mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 11mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D8.0mm_H7.0mm_P3.50mm +C, Radial series, Radial, pin pitch=3.50mm, diameter=8mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 3.50mm diameter 8mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D8.0mm_H11.5mm_P3.50mm +C, Radial series, Radial, pin pitch=3.50mm, diameter=8mm, height=11.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 3.50mm diameter 8mm height 11.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H12.5mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=12.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 12.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H16.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=16mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 16mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H20.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=20mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 20mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D12.5mm_H20.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=12.5mm, height=20mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 12.5mm height 20mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D12.5mm_H25.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=12.5mm, height=25mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 12.5mm height 25mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D16.0mm_H25.0mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=16mm, height=25mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 16mm height 25mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D16.0mm_H31.5mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=16mm, height=31.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 16mm height 31.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D18.0mm_H35.5mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=18mm, height=35.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 18mm height 35.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.0mm_W2.5mm_P2.50mm +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4*2.5mm^2, Capacitor +C Rect series Radial pin pitch 2.50mm length 4mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W2.0mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*2mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W3.0mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*3.0mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W3.8mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*3.8mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 3.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W4.6mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*4.6mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 4.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W5.5mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*5.5mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 5.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W2.0mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*2mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W2.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*2.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W3.5mm_P2.50mm_P5.00mm +C, Rect series, Radial, pin pitch=2.50mm 5.00mm, , length*width=7*3.5mm^2, Capacitor +C Rect series Radial pin pitch 2.50mm 5.00mm length 7mm width 3.5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L7.0mm_W3.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*3.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W4.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*4.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W6.0mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*6mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W6.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*6.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 6.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W2.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*2.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W3.0mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*3.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W3.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*3.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W4.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*4.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W5.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*5.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 5.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W7.2mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*7.2mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 7.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W8.5mm_P5.00mm_FKP2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*8.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W11.0mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.5mm_W6.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.5*6.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7.5mm width 6.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.6mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.2mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.3mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.4mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.6mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.8mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.9mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.0mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.2mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.9mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W5.1mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W5.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*5.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 5.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W6.4mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W6.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*6.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 6.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W7.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*7.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 7.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W8.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*8.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W9.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*9.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 9.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W9.8mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*9.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 9.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W2.5mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*2.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W3.0mm_P7.50mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*3mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W3.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*3.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W4.0mm_P7.50mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W4.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*4.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W5.0mm_P5.00mm_P7.50mm +C, Rect series, Radial, pin pitch=5.00mm 7.50mm, , length*width=10*5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm 7.50mm length 10mm width 5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L10.3mm_W4.5mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*4.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W5.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W5.7mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*5.7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 5.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W7.2mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*7.2mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 7.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W2.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*2.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 2.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W3.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*3.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 3.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W3.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*3.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W4.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*4.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 4.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W4.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*4.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 4.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W5.1mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W5.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*5.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 5.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W6.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*6.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 6.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W6.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W7.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W8.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*8.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 8.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.1mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.9mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W8.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*8.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 8.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W8.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*8.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 8.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W9.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*9.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 9.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W9.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*9.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 9.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W3.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*3mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W4.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W5.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W6.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W6.5mm_P7.50mm_P10.00mm +C, Rect series, Radial, pin pitch=7.50mm 10.00mm, , length*width=13*6.5mm^2, Capacitor +C Rect series Radial pin pitch 7.50mm 10.00mm length 13mm width 6.5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L13.0mm_W8.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.5mm_W4.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13.5*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13.5mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.5mm_W5.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13.5*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W4.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*4.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 4.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W4.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*4.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 4.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W5.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W6.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W7.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W7.3mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W8.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*8.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 8.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W8.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*8.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 8.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W9.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W9.2mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*9.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 9.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W10.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*10.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 10.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W10.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*10.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 10.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W11.2mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*11.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 11.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W11.8mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*11.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 11.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.5mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W5.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W6.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W7.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W8.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W9.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W11.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W5.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W6.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W7.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W8.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W9.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W11.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W7.0mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W8.3mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*8.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 8.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W8.6mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*8.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 8.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.1mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.3mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.9mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.2mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.6mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.8mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W5.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W6.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W7.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W8.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*8.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W10.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*10.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 10.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W11.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*11.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 11.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W9.0mm_P22.00mm +C, Rect series, Radial, pin pitch=22.00mm, , length*width=27*9mm^2, Capacitor +C Rect series Radial pin pitch 22.00mm length 27mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W9.0mm_P23.00mm +C, Rect series, Radial, pin pitch=23.00mm, , length*width=27*9mm^2, Capacitor +C Rect series Radial pin pitch 23.00mm length 27mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W11.0mm_P22.00mm +C, Rect series, Radial, pin pitch=22.00mm, , length*width=27*11mm^2, Capacitor +C Rect series Radial pin pitch 22.00mm length 27mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W8.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W10.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*10mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 10mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W12.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*12mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 12mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.6mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.8mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.9mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W9.1mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*9.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 9.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W9.6mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*9.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 9.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W11.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*11mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W11.9mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*11.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 11.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W12.2mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*12.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 12.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W13.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*13mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W13.8mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*13.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 13.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W14.2mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*14.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 14.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W16.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*16mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 16mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W9.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W11.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W13.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W15.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W17.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*17mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 17mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W20.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L32.0mm_W15.0mm_P27.00mm +C, Rect series, Radial, pin pitch=27.00mm, , length*width=32*15mm^2, Capacitor +C Rect series Radial pin pitch 27.00mm length 32mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W13.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W15.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W20.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W9.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W11.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W13.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W15.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W17.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*17mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 17mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W19.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*19mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 19mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W20.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W24.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*24mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 24mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W31.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*31mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 31mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W35.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*35mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 35mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W40.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*40mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 40mm Capacitor +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-08_AVX-J +Tantalum Capacitor SMD AVX-J (1608-08 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-08_AVX-J_Pad1.25x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-J (1608-08 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-10_AVX-L +Tantalum Capacitor SMD AVX-L (1608-10 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-10_AVX-L_Pad1.25x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-L (1608-10 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-12_Kemet-R +Tantalum Capacitor SMD Kemet-R (2012-12 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-12_Kemet-R_Pad1.30x1.05mm_HandSolder +Tantalum Capacitor SMD Kemet-R (2012-12 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-15_AVX-P +Tantalum Capacitor SMD AVX-P (2012-15 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-15_AVX-P_Pad1.30x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-P (2012-15 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-10_Kemet-I +Tantalum Capacitor SMD Kemet-I (3216-10 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-10_Kemet-I_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-I (3216-10 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-12_Kemet-S +Tantalum Capacitor SMD Kemet-S (3216-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-12_Kemet-S_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-S (3216-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-18_Kemet-A +Tantalum Capacitor SMD Kemet-A (3216-18 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-18_Kemet-A_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-A (3216-18 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-12_Kemet-T +Tantalum Capacitor SMD Kemet-T (3528-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-12_Kemet-T_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-T (3528-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-15_AVX-H +Tantalum Capacitor SMD AVX-H (3528-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-15_AVX-H_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD AVX-H (3528-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-21_Kemet-B +Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-21_Kemet-B_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-15_Kemet-U +Tantalum Capacitor SMD Kemet-U (6032-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-15_Kemet-U_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-U (6032-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-20_AVX-F +Tantalum Capacitor SMD AVX-F (6032-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-20_AVX-F_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD AVX-F (6032-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-28_Kemet-C +Tantalum Capacitor SMD Kemet-C (6032-28 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-28_Kemet-C_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-C (6032-28 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-20_AVX-U +Tantalum Capacitor SMD AVX-U (7132-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-20_AVX-U_Pad2.72x3.50mm_HandSolder +Tantalum Capacitor SMD AVX-U (7132-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-28_AVX-C +Tantalum Capacitor SMD AVX-C (7132-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-28_AVX-C_Pad2.72x3.50mm_HandSolder +Tantalum Capacitor SMD AVX-C (7132-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-15_AVX-R +Tantalum Capacitor SMD AVX-R (7260-15 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-15_AVX-R_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-R (7260-15 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-20_AVX-M +Tantalum Capacitor SMD AVX-M (7260-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-20_AVX-M_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-M (7260-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-28_AVX-M +Tantalum Capacitor SMD AVX-M (7260-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-28_AVX-M_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-M (7260-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-38_AVX-R +Tantalum Capacitor SMD AVX-R (7260-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-38_AVX-R_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-R (7260-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-15_Kemet-W +Tantalum Capacitor SMD Kemet-W (7343-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-15_Kemet-W_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-W (7343-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-20_Kemet-V +Tantalum Capacitor SMD Kemet-V (7343-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-20_Kemet-V_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-V (7343-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-30_AVX-N +Tantalum Capacitor SMD AVX-N (7343-30 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-30_AVX-N_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD AVX-N (7343-30 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-31_Kemet-D +Tantalum Capacitor SMD Kemet-D (7343-31 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-31_Kemet-D_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-D (7343-31 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-40_Kemet-Y +Tantalum Capacitor SMD Kemet-Y (7343-40 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-40_Kemet-Y_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-Y (7343-40 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-43_Kemet-X +Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-43_Kemet-X_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7360-38_Kemet-E +Tantalum Capacitor SMD Kemet-E (7360-38 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7360-38_Kemet-E_Pad2.25x4.25mm_HandSolder +Tantalum Capacitor SMD Kemet-E (7360-38 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-38_AVX-V +Tantalum Capacitor SMD AVX-V (7361-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-38_AVX-V_Pad2.18x3.30mm_HandSolder +Tantalum Capacitor SMD AVX-V (7361-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-438_AVX-U +Tantalum Capacitor SMD AVX-U (7361-438 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-438_AVX-U_Pad2.18x3.30mm_HandSolder +Tantalum Capacitor SMD AVX-U (7361-438 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Connector +Banana_Jack_1Pin +Single banana socket, footprint - 6mm drill +banana socket +0 +1 +1 +Connector +Banana_Jack_2Pin +Dual banana socket, footprint - 2 x 6mm drills +banana socket +0 +2 +2 +Connector +Banana_Jack_3Pin +Triple banana socket, footprint - 3 x 6mm drills +banana socket +0 +3 +3 +Connector +CUI_PD-30 +3 pin connector, PD-30, http://www.cui.com/product/resource/pd-30.pdf +connector 3-pin PD-30 power DIN +0 +4 +4 +Connector +CalTest_CT3151 +Right-angle standard banana jack, http://www.caltestelectronics.com/images/attachments/P315100rH_drawing.pdf +banana jack horizontal +0 +4 +1 +Connector +Connector_SFP_and_Cage +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=2227302&DocType=Customer+Drawing&DocLang=English +SFP+ SFP +0 +40 +21 +Connector +DTF13-12Px +http://www.te.com/usa-en/product-DTF13-12PA-G003.html +DEUTSCH DT header 12 pin +0 +12 +12 +Connector +FanPinHeader_1x03_P2.54mm_Vertical +3-pin CPU fan Through hole pin header, see http://www.formfactors.org/developer%5Cspecs%5Crev1_2_public.pdf +pin header 3-pin CPU fan +0 +3 +3 +Connector +FanPinHeader_1x04_P2.54mm_Vertical +4-pin CPU fan Through hole pin header, e.g. for Wieson part number 2366C888-007 Molex 47053-1000, Foxconn HF27040-M1, Tyco 1470947-1 or equivalent, see http://www.formfactors.org/developer%5Cspecs%5Crev1_2_public.pdf +pin header 4-pin CPU fan +0 +4 +4 +Connector +GB042-34S-H10 +http://www.lsmtron.com/pdf/Connector&Antenna_catalog.PDF +34pin SMD connector +0 +34 +34 +Connector +IHI_B6A-PCB-45_Vertical +https://lugsdirect.com/PDF_Webprint/B6A-PCB-45-XX(-X).pdf +connector IHI B6A-PCB-45 +0 +49 +1 +Connector +JWT_A3963_1x02_P3.96mm_Vertical +JWT A3963, 3.96mm pitch Pin head connector (http://www.jwt.com.tw/pro_pdf/A3963.pdf) +connector JWT A3963 pinhead +0 +2 +2 +Connector +NS-Tech_Grove_1x04_P2mm_Vertical +https://statics3.seeedstudio.com/images/opl/datasheet/3470130P1.pdf +Grove-1x04 +0 +4 +4 +Connector +SpringContact_Harwin_S1941-46R +7.25mm SMT Multi-directional Spring Contact (T+R), https://cdn.harwin.com/pdfs/S1941R.pdf +spring contact emi emc shield +0 +1 +1 +Connector +Tag-Connect_TC2030-IDC-FP_2x03_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2030-IDC.pdf +tag connect programming header pogo pins +0 +6 +6 +Connector +Tag-Connect_TC2030-IDC-NL_2x03_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2030-IDC-NL.pdf +tag connect programming header pogo pins +0 +6 +6 +Connector +Tag-Connect_TC2050-IDC-FP_2x05_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2050-IDC-430%20Datasheet.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2050-IDC-NL_2x05_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2050-IDC-NL%20Datasheet.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2050-IDC-NL_2x05_P1.27mm_Vertical_with_bottom_clip +Tag-Connect programming header with bottom courtyard for TC2050-NL Clip board ; https://www.tag-connect.com/wp-content/uploads/bsk-pdf-manager/TC2050-IDC-NL_Datasheet_8.pdf https://www.tag-connect.com/wp-content/uploads/bsk-pdf-manager/TC2050-CLIP_Datasheet_25.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2070-IDC-FP_2x07_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2070-IDC%20Datasheet.pdf +tag connect programming header pogo pins +0 +14 +14 +Connector_AMASS +AMASS_MR30PW-FB_1x03_P3.50mm_Horizontal +Connector XT30 Horizontal PCB Female, https://www.tme.eu/en/Document/5e47640ba39fa492dbd4c0f4c8ae7b93/MR30PW%20SPEC.pdf +RC Connector XT30 +0 +5 +3 +Connector_AMASS +AMASS_MR30PW-M_1x03_P3.50mm_Horizontal +Connector XT30 Horizontal PCB Male, https://www.tme.eu/en/Document/5e47640ba39fa492dbd4c0f4c8ae7b93/MR30PW%20SPEC.pdf +RC Connector XT30 +0 +5 +3 +Connector_AMASS +AMASS_XT30PW-F_1x02_P2.50mm_Horizontal +Connector XT30 Horizontal PCB Female, https://www.tme.eu/en/Document/ce4077e36b79046da520ca73227e15de/XT30PW%20SPEC.pdf +RC Connector XT30 +0 +4 +2 +Connector_AMASS +AMASS_XT30PW-M_1x02_P2.50mm_Horizontal +Connector XT30 Horizontal PCB Male, https://www.tme.eu/en/Document/ce4077e36b79046da520ca73227e15de/XT30PW%20SPEC.pdf +RC Connector XT30 +0 +4 +2 +Connector_AMASS +AMASS_XT30U-F_1x02_P5.0mm_Vertical +Connector XT30 Vertical Cable Female, https://www.tme.eu/en/Document/3cbfa5cfa544d79584972dd5234a409e/XT30U%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30U-M_1x02_P5.0mm_Vertical +Connector XT30 Vertical Cable Male, https://www.tme.eu/en/Document/3cbfa5cfa544d79584972dd5234a409e/XT30U%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30UPB-F_1x02_P5.0mm_Vertical +Connector XT30 Vertical PCB Female, https://www.tme.eu/en/Document/4acc913878197f8c2e30d4b8cdc47230/XT30UPB%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30UPB-M_1x02_P5.0mm_Vertical +Connector XT30 Vertical PCB Male, https://www.tme.eu/en/Document/4acc913878197f8c2e30d4b8cdc47230/XT30UPB%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT60-F_1x02_P7.20mm_Vertical +AMASS female XT60, through hole, vertical, https://www.tme.eu/Document/2d152ced3b7a446066e6c419d84bb460/XT60%20SPEC.pdf +XT60 female vertical +0 +2 +2 +Connector_AMASS +AMASS_XT60-M_1x02_P7.20mm_Vertical +AMASS female XT60, through hole, vertical, https://www.tme.eu/Document/2d152ced3b7a446066e6c419d84bb460/XT60%20SPEC.pdf +XT60 female vertical +0 +2 +2 +Connector_Amphenol +Amphenol_M8S-03PMMR-SF8001 +M8 Male connector for panel, 90° PCB mount (https://www.amphenolltw.com/2012download/2D%20PDF/03_M%20Series%20Sensor%20Connectors/M8S-XXPMMR-SF8001.pdf) +three-pin M8 +0 +5 +4 +Connector_Audio +Jack_3.5mm_CUI_SJ-3523-SMT_Horizontal +3.5 mm, Stereo, Right Angle, Surface Mount (SMT), Audio Jack Connector (https://www.cui.com/product/resource/sj-352x-smt-series.pdf) +3.5mm audio cui horizontal jack stereo +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ-3524-SMT_Horizontal +3.5 mm, Stereo, Right Angle, Surface Mount (SMT), Audio Jack Connector (https://www.cui.com/product/resource/sj-352x-smt-series.pdf) +3.5mm audio cui horizontal jack stereo +0 +4 +4 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3533NG_Horizontal +TRS 3.5mm, horizontal, through-hole, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3533NG_Horizontal_CircularHoles +TRS 3.5mm, horizontal, through-hole, , circular holeshttps://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal circular +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3535NG_Horizontal +TRS 3.5mm, horizontal, through-hole, with switch, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal +0 +5 +5 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3535NG_Horizontal_CircularHoles +TRS 3.5mm, horizontal, through-hole, with switch, circular holes, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal circular +0 +5 +5 +Connector_Audio +Jack_3.5mm_Ledino_KB3SPRS_Horizontal +https://www.reichelt.de/index.html?ACTION=7&LA=3&OPEN=0&INDEX=0&FILENAME=C160%252FKB3SPRS.pdf +jack stereo TRS +0 +5 +5 +Connector_Audio +Jack_3.5mm_PJ311_Horizontal +PJ311 6pin SMD 3.5mm stereo headphones jack. +headphones jack plug stereo 3.5mm PJ311 +0 +6 +6 +Connector_Audio +Jack_3.5mm_PJ320D_Horizontal +Headphones with microphone connector, 3.5mm, 4 pins (http://www.qingpu-electronics.com/en/products/WQP-PJ320D-72.html) +3.5mm jack mic microphone phones headphones 4pins audio plug +0 +4 +4 +Connector_Audio +Jack_3.5mm_PJ320E_Horizontal +Headphones with microphone connector, 3.5mm, 4 pins (http://www.qingpu-electronics.com/en/products/WQP-PJ320E-177.html) +3.5mm jack mic microphone phones headphones 4pins audio plug +0 +5 +4 +Connector_Audio +Jack_3.5mm_PJ31060-I_Horizontal +PJ31060-I 6pin SMD 3.5mm headphones jack (http://www.china-bsun.com/Product48/1577.html) +headphones jack plug stereo 3.5mm PJ31060-I PJ31060 +0 +6 +6 +Connector_Audio +Jack_3.5mm_QingPu_WQP-PJ398SM_Vertical_CircularHoles +TRS 3.5mm, vertical, Thonkiconn, PCB mount, (http://www.qingpu-electronics.com/en/products/WQP-PJ398SM-362.html) +WQP-PJ398SM WQP-PJ301M-12 TRS 3.5mm mono vertical jack thonkiconn qingpu +0 +3 +3 +Connector_Audio +Jack_3.5mm_Switronic_ST-005-G_horizontal +3.5mm horizontal headphones jack, http://akizukidenshi.com/download/ds/switronic/ST-005-G.pdf +Connector Audio Switronic ST-005-G +0 +4 +3 +Connector_Audio +Jack_6.35mm_Neutrik_NJ2FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, Non-switching mono jack (T/S), https://www.neutrik.com/en/product/nj2fd-v +neutrik jack vertical +0 +2 +2 +Connector_Audio +Jack_6.35mm_Neutrik_NJ3FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, Non-switching stereo jack (T/R/S), https://www.neutrik.com/en/product/nj3fd-v +neutrik jack vertical +0 +3 +3 +Connector_Audio +Jack_6.35mm_Neutrik_NJ5FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, 2 x switching (normalling) stereo jack (T/TN/R/RN/S), https://www.neutrik.com/en/product/nj5fd-v +neutrik jack vertical +0 +5 +5 +Connector_Audio +Jack_6.35mm_Neutrik_NJ6FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, 3 x switching (normalling) stereo jack (T/TN/R/RN/S/SN), https://www.neutrik.com/en/product/nj6fd-v +neutrik jack vertical +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NJ6TB-V_Vertical +6.35mm (1/4 in) Vertical Jack, 3 x switching (normalling) stereo jack B-gauge type (T/TN/R/RN/S/SN), https://www.neutrik.com/en/product/nj6tb-v +neutrik jack vertical +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HCD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with chrome ferrule and straight PCB pins, https://www.neutrik.com/en/product/nmj4hcd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HFD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with full threaded nose and straight PCB pins, https://www.neutrik.com/en/product/nmj4hfd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HFD3_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with a full threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj4hfd3 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HHD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with a half threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj4hhd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HCD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with chrome ferrule and straight PCB pins, https://www.neutrik.com/en/product/nmj6hcd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HCD3_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with chrome ferrule and offset PCB pins, https://www.neutrik.com/en/product/nmj6hcd3 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD2-AU_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, full threaded nose, straight PCB pins, gold plated contacts, https://www.neutrik.com/en/product/nmj6hfd2-au +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and straight PCB pins, https://www.neutrik.com/en/product/nmj6hfd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD3_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj6hfd3 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD4_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and fishtail PCB pins, https://www.neutrik.com/en/product/nmj6hfd4 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HHD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with half threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj6hhd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ3HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, unswitched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj3hf-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj4hf-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HF_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, fully threaded nose, https://www.neutrik.com/en/product/nrj4hf +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HH-1_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, half threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj4hh-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HH_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, half threaded nose, https://www.neutrik.com/en/product/nrj4hh +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-1-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hf-1-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hf-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, fully threaded nose, https://www.neutrik.com/en/product/nrj6hf-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, fully threaded nose, https://www.neutrik.com/en/product/nrj6hf +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, half threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hh-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, half threaded nose, https://www.neutrik.com/en/product/nrj6hh-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, half threaded nose, https://www.neutrik.com/en/product/nrj6hh +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose, gold plated contacts, efficient chassis ground connection, T+R+S normalling contact, https://www.neutrik.com/en/product/nrj6hm-1-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1-PRE_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose, efficient chassis ground connection, T+R normalling contact, https://www.neutrik.com/en/product/nrj6hm-1-pre +neutrik jack slim +0 +6 +5 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose with efficient chassis ground connection, T+R+S normalling contact, https://www.neutrik.com/en/product/nrj6hm-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ8HC_Horizontal +Stacking Jacks, Mono dual jack, full nose, https://www.neutrik.com/en/product/nsj8hc +neutrik jack stacking +0 +9 +9 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ8HL_Horizontal +Stacking Jacks, Mono dual jack, quick fix nose, https://www.neutrik.com/en/product/nsj8hl +neutrik jack stacking +0 +9 +9 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HC_Horizontal +Stacking Jacks, Stereo dual jack, full nose, https://www.neutrik.com/en/product/nsj12hc +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HF-1_Horizontal +Stacking Jacks, Stereo dual jack, full threaded nose, https://www.neutrik.com/en/product/nsj12hf-1 +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HH-1_Horizontal +Stacking Jacks, Stereo dual jack, half threaded nose, https://www.neutrik.com/en/product/nsj12hh-1 +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HL_Horizontal +Stacking Jacks, Stereo dual jack, quick fix nose, https://www.neutrik.com/en/product/nsj12hl +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj5fi-h-0 +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj5fi-h +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj5fi-v-0 +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj5fi-v +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H-0_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fa-h-0 +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H-DA_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/ncj6fa-h-da +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, https://www.neutrik.com/en/product/ncj6fa-h +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V-0_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fa-v-0 +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V-DA_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/ncj6fa-v-da +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, https://www.neutrik.com/en/product/ncj6fa-v +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj6fi-h-0 +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fi-h +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj6fi-v-0 +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fi-v +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, horizontal PCB mount, https://www.neutrik.com/en/product/ncj9fi-h-0 +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj9fi-h +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, vertical PCB mount, https://www.neutrik.com/en/product/ncj9fi-v-0 +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj9fi-v +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj10fi-h-0 +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj10fi-h +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj10fi-v-0 +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj10fi-v +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah1-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1-DA_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3faah1-da +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH2-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah2-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH2_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah2 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV-0_Vertical +AA Series, 3 pole female receptacle, grounding: without ground/shell contact, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1-0_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav1-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1-DA_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3faav1-da +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV2-0_Vertical +AA Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav2-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV2_Vertical +AA Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav2 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV_Vertical +AA Series, 3 pole female receptacle, grounding: without ground/shell contact, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1-DA_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fah1-da +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2-DA_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fah2-da +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, lateral left PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3fahl1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3fahr1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR2-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR2_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3fahr2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1-DA_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fav1-da +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2-DA_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fav2-da +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV_Vertical +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-B_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbh1-b +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-DA_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbh1-da +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-E_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3fbh1-e +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fbh1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-B_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbh2-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-DA_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbh2-da +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-E_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3fbh2-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fbh2 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBHL1_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3fbhl1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-0_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring, no latch, https://www.neutrik.com/en/product/nc3fbv1-0 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-B_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbv1-b +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-DA_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbv1-da +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-B_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbv2-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-DA_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbv2-da +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-SW_Vertical +B Series, 3 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv2-sw +neutrik xlr b +0 +7 +7 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv2 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH-0_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH-1_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah-1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV-0_Vertical +AA Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV-1_Vertical +AA Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav-1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV_Vertical +AA Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAFH-PH_Horizontal +A Series, Chassis connector H female (A series layout), horizontal PCB mount, https://www.neutrik.com/en/product/nc4mafh-ph +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAH-0_Horizontal +A Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mah-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAHL_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3mahl +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAHR_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3mahr +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAH_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mah +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAMH-PH_Horizontal +A Series, Chassis connector Phoenix H male (A series layout), horizontal PCB mount, https://www.neutrik.com/en/product/nc4mamh-ph +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAV-0_Vertical +A Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, vertical PCB mount, https://www.neutrik.com/en/product/nc3mav-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAV_Vertical +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3mav +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-0_Horizontal +B Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh-0 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-1_Horizontal +B Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh-1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbh-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-E_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3mbh-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHL-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral left PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbhl-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHL_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral left PCB mount, https://www.neutrik.com/en/product/nc3mbhl +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHR-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral right PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbhr-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHR_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral right PCB mount, https://www.neutrik.com/en/product/nc3mbhr +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-0_Vertical +B Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-0 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-1_Vertical +B Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-B_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbv-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-E_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3mbv-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-SW_Vertical +B Series, 3 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-sw +neutrik xlr b +0 +7 +7 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC4FAH-0_Horizontal +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc4fah-0 +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAH_Horizontal +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4fah +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAV-0_Vertical +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc4fav-0 +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAV_Vertical +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4fav +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FBH_Horizontal +B Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4fbh +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FBV_Vertical +B Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4fbv +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MAH_Horizontal +A Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4mah +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MAV_Vertical +A Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4mav +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MBH_Horizontal +B Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4mbh +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MBV_Vertical +B Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4mbv +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH-0_Horizontal +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc5fah-0 +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH-DA_Horizontal +A Series, 5 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc5fah-da +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH_Horizontal +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5fah +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV-DA_Vertical +A Series, 5 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc5fav-da +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV-SW_Vertical +A Series, 5 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, color coding possible, https://www.neutrik.com/en/product/nc5fav-sw +neutrik xlr a +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV_Vertical +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fav +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBH-B_Horizontal +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5fbh-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBH_Horizontal +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5fbh +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV-B_Vertical +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5fbv-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV-SW_Vertical +B Series, 5 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fbv-sw +neutrik xlr b +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV_Vertical +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fbv +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MAH_Horizontal +A Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5mah +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MAV-SW_Vertical +A Series, 5 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mav-sw +neutrik xlr a +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5MAV_Vertical +A Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mav +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBH-B_Horizontal +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5mbh-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBH_Horizontal +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5mbh +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV-B_Vertical +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5mbv-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV-SW_Vertical +B Series, 5 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mbv-sw +neutrik xlr b +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV_Vertical +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mbv +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_speakON-6.35mm_Neutrik_NLJ2MD-H_Horizontal +speakON Combo, 2 pole combination of speakON socket and 6.35mm (1/4in) jack receptacle, horizontal pcb mount, https://www.neutrik.com/en/product/nlj2md-h +neutrik speakon combo +0 +2 +2 +Connector_Audio +Jack_speakON-6.35mm_Neutrik_NLJ2MD-V_Vertical +speakON Combo, 2 pole combination of speakON socket and 6.35mm (1/4in) jack receptacle, vertical pcb mount, https://www.neutrik.com/en/product/nlj2md-v +neutrik speakon combo +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL2MD-H_Horizontal +speakON Chassis Connectors, 2 pole chassis connector, gray D-size flange, countersunk thru holes, horizontal PCB, https://www.neutrik.com/en/product/nl2md-h +neutrik speakon +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL2MD-V_Vertical +speakON Chassis Connectors, 2 pole chassis connector, black D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl2md-v +neutrik speakon +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-1_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, countersunk thru holes, horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-1 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-2_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, mirrored self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-2 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-3_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-3 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, grey D-size flange, self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-1_Vertical +speakON Chassis Connectors, 4 pole chassis connector, grey D-size flange, self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-1 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-2_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, mirrored self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-2 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-R_Vertical +speakON Chassis Connectors, 4 pole chassis connector, red D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-r +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-S_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, switchable version of NL4MD-V with 8 vertical PCB contacts (4 switching contacts), https://www.neutrik.com/en/product/nl4md-v-s +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL8MD-V-1_Vertical +speakON Chassis Connectors, 8 pole chassis connector, nickel metal square G-size flange, self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl8md-v-1 +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NL8MD-V_Vertical +speakON Chassis Connectors, 8 pole chassis connector, nickel metal square G-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl8md-v +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NLT4MD-V_Vertical +STX Series, 4 pole male chassis connector, metal housing, vertical PCB mount, self tapping screw holes (A-screw), https://www.neutrik.com/en/product/nlt4md-v +neutrik speakon stx +0 +4 +4 +Connector_Audio +MiniXLR-5_Switchcraft_TRAPC_Horizontal +http://www.switchcraft.com/ProductSummary.aspx?Parent=620 http://www.switchcraft.com/Drawings/TRAPC_X-TRASM_X_SERIES_CD.PDF +THT Mini XLR 5Pin right angle +0 +5 +5 +Connector_BarrelJack +BarrelJack_CLIFF_FC681465S_SMT_Horizontal +Surface-mount DC Barrel Jack, https://www.cliffuk.co.uk/products/dcconnectors/FC681465S.pdf +Power Jack SMT +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-036AH-SMT_Horizontal +Surface-mount DC Barrel Jack, http://www.cui.com/product/resource/pj-036ah-smt.pdf +Power Jack SMT +0 +3 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-063AH_Horizontal +Barrel Jack, 2.0mm ID, 5.5mm OD, 24V, 8A, no switch, https://www.cui.com/product/resource/pj-063ah.pdf +barrel jack cui dc power +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-063AH_Horizontal_CircularHoles +Barrel Jack, 2.0mm ID, 5.5mm OD, 24V, 8A, no switch, https://www.cui.com/product/resource/pj-063ah.pdf +barrel jack cui dc power +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-102AH_Horizontal +Thin-pin DC Barrel Jack, https://cdn-shop.adafruit.com/datasheets/21mmdcjackDatasheet.pdf +Power Jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_Horizontal +DC Barrel Jack +Power Jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_Wuerth_6941xx301002 +Wuerth electronics barrel jack connector (5.5mm outher diameter, inner diameter 2.05mm or 2.55mm depending on exact order number), See: http://katalog.we-online.de/em/datasheet/6941xx301002.pdf +connector barrel jack +0 +3 +3 +Connector_Card +CF-Card_3M_N7E50-7516PK-20-WF +Compact Flash Card connector (https://multimedia.3m.com/mws/media/22365O/3mtm-cf-card-header-compactflashtm-type-i-sm-ts0662.pdf) +connector cf +0 +54 +50 +Connector_Card +SD_Kyocera_145638009211859+ +SD Card Connector, Normal Type, Outer Tail, Without Ejector (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638009511859+ +SD Card Connector, Normal Type, Outer Tail, Spring Eject Type (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638109211859+ +SD Card Connector, Reverse Type, Outer Tail, Without Ejector (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638109511859+ +SD Card Connector, Reverse Type, Outer Tail, Spring Eject Type (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_TE_2041021 +SD card connector, top mount, SMT (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F2041021%7FB%7Fpdf%7FEnglish%7FENG_CD_2041021_B_C_2041021_B.pdf%7F2041021-4) +sd card +0 +15 +12 +Connector_Card +microSD_HC_Hirose_DM3AT-SF-PEJM5 +Micro SD, SMD, right-angle, push-pull (https://www.hirose.com/product/en/download_file/key_name/DM3AT-SF-PEJM5/category/Drawing%20(2D)/doc_file_id/44099/?file_category_id=6&item_id=06090031000&is_series=) +Micro SD +0 +14 +11 +Connector_Card +microSD_HC_Hirose_DM3BT-DSF-PEJS +Micro SD, SMD, reverse on-board, right-angle, push-pull (https://www.hirose.com/product/en/download_file/key_name/DM3BT-DSF-PEJS/category/Drawing%20(2D)/doc_file_id/44097/?file_category_id=6&item_id=06090029900&is_series=) +Micro SD +0 +16 +11 +Connector_Card +microSD_HC_Hirose_DM3D-SF +Micro SD, SMD, right-angle, push-pull (https://media.digikey.com/PDF/Data%20Sheets/Hirose%20PDFs/DM3D-SF.pdf) +Micro SD +0 +14 +11 +Connector_Card +microSD_HC_Molex_104031-0811 +1.10mm Pitch microSD Memory Card Connector, Surface Mount, Push-Pull Type, 1.42mm Height, with Detect Switch (https://www.molex.com/pdm_docs/sd/1040310811_sd.pdf) +microSD SD molex +0 +14 +11 +Connector_Card +microSD_HC_Wuerth_693072010801 +http://katalog.we-online.de/em/datasheet/693072010801.pdf +Micro SD Wuerth Wurth Würth +0 +12 +9 +Connector_Card +microSIM_JAE_SF53S006VCBR2000 +https://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ115712.pdf +microSIM GSM Card +0 +14 +7 +Connector_Coaxial +BNC_Amphenol_031-6575_Horizontal +dual independently isolated BNC plug (https://www.amphenolrf.com/downloads/dl/file/id/2980/product/644/031_6575_customer_drawing.pdf) +Dual BNC Amphenol Horizontal +0 +6 +4 +Connector_Coaxial +BNC_Amphenol_B6252HB-NPP3G-50_Horizontal +http://www.farnell.com/datasheets/612848.pdf +BNC Amphenol Horizontal +0 +4 +2 +Connector_Coaxial +BNC_PanelMountable_Vertical +Panel-mountable BNC connector mounted through PCB, vertical +BNC connector +0 +2 +2 +Connector_Coaxial +BNC_TEConnectivity_1478204_Vertical +BNC female PCB mount 4 pin straight chassis connector http://www.te.com/usa-en/product-1-1478204-0.html +BNC female PCB mount 4 pin straight chassis connector +0 +5 +2 +Connector_Coaxial +BNC_Win_364A2x95_Horizontal +Dual front isolated BNC plug (https://www.winconn.com/wp-content/uploads/364A2595.pdf) +Dual BNC Horizontal Isolated +0 +6 +3 +Connector_Coaxial +CoaxialSwitch_Hirose_MS-156C3_Horizontal +Subminiature Coaxial Switch 1.35mm High, DC to 11GHz +Switch Coaxial RF +0 +12 +3 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_0.8mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_1.0mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_1.6mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-1471_Vertical +http://www.molex.com/pdm_docs/sd/734151471_sd.pdf +Molex MMCX Coaxial Connector 50 ohms Female Jack Vertical THT +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_901-144_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/7023/product/3103/901_144_customer_drawing.pdf +SMA THT Female Jack Vertical +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-10_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/4007/product/2974/132134_10_customer_drawing.pdf +SMA SMD Female Jack Vertical +0 +3 +2 +Connector_Coaxial +SMA_Amphenol_132134-11_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/3406/product/2975/132134_11_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-14_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1793/product/2976/132134_14_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-16_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1141/product/2978/132134_16_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/2187/product/2843/132134_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132203-12_Horizontal +https://www.amphenolrf.com/media/downloads/1769/132203-12.pdf +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132289_EdgeMount +http://www.amphenolrf.com/132289.html +SMA +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132291-12_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1688/product/3020/132291_12_customer_drawing.pdf +SMA THT Female Jack Vertical Bulkhead +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132291_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/3222/product/2918/132291_customer_drawing.pdf +SMA THT Female Jack Vertical Bulkhead +0 +5 +2 +Connector_Coaxial +SMA_Molex_73251-1153_EdgeMount_Horizontal +Molex SMA RF Connectors, Edge Mount, (http://www.molex.com/pdm_docs/sd/732511150_sd.pdf) +sma edge +0 +11 +2 +Connector_Coaxial +SMA_Molex_73251-2120_EdgeMount_Horizontal +Molex SMA RF Connector, Edge Mount, (http://www.molex.com/pdm_docs/sd/732512120_sd.pdf) +sma edge +0 +11 +2 +Connector_Coaxial +SMA_Molex_73251-2200_Horizontal +https://www.molex.com/webdocs/datasheets/pdf/en-us/0732512200_RF_COAX_CONNECTORS.pdf +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Samtec_SMA-J-P-X-ST-EM1_EdgeMount +Connector SMA, 0Hz to 20GHz, 50Ohm, Edge Mount (http://suddendocs.samtec.com/prints/sma-j-p-x-st-em1-mkt.pdf) +SMA Straight Samtec Edge Mount +0 +5 +2 +Connector_Coaxial +SMA_Wurth_60312002114503_Vertical +https://www.we-online.de/katalog/datasheet/60312002114503.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMB_Jack_Vertical +SMB pcb mounting jack +SMB Jack Striaght +0 +5 +2 +Connector_Coaxial +U.FL_Hirose_U.FL-R-SMT-1_Vertical +Hirose U.FL Coaxial https://www.hirose.com/product/en/products/U.FL/U.FL-R-SMT-1%2810%29/ +Hirose U.FL Coaxial +0 +3 +2 +Connector_Coaxial +U.FL_Molex_MCRF_73412-0110_Vertical +Molex Microcoaxial RF Connectors (MCRF), mates Hirose U.FL, (http://www.molex.com/pdm_docs/sd/734120110_sd.pdf) +mcrf hirose ufl u.fl microcoaxial +0 +4 +2 +Connector_DIN +DIN41612_B2_2x8_Female_Vertical_THT +DIN41612 connector, type B/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +16 +16 +Connector_DIN +DIN41612_B2_2x8_Male_Horizontal_THT +DIN41612 connector, type B/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +16 +16 +Connector_DIN +DIN41612_B2_2x16_Female_Vertical_THT +DIN41612 connector, type B/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +32 +32 +Connector_DIN +DIN41612_B2_2x16_Male_Horizontal_THT +DIN41612 connector, type B/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +32 +32 +Connector_DIN +DIN41612_B3_2x5_Female_Vertical_THT +DIN41612 connector, type B/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +10 +10 +Connector_DIN +DIN41612_B3_2x5_Male_Horizontal_THT +DIN41612 connector, type B/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +10 +10 +Connector_DIN +DIN41612_B3_2x10_Female_Vertical_THT +DIN41612 connector, type B/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +20 +20 +Connector_DIN +DIN41612_B3_2x10_Male_Horizontal_THT +DIN41612 connector, type B/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +20 +20 +Connector_DIN +DIN41612_B_1x32_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_1x32_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x16_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x16_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x32_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +64 +64 +Connector_DIN +DIN41612_B_2x32_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +64 +64 +Connector_DIN +DIN41612_C2_2x16_Female_Vertical_THT +DIN41612 connector, type C/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +32 +32 +Connector_DIN +DIN41612_C2_2x16_Male_Horizontal_THT +DIN41612 connector, type C/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +32 +32 +Connector_DIN +DIN41612_C2_3x16_Female_Vertical_THT +DIN41612 connector, type C/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +48 +48 +Connector_DIN +DIN41612_C2_3x16_Male_Horizontal_THT +DIN41612 connector, type C/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +48 +48 +Connector_DIN +DIN41612_C3_2x10_Female_Vertical_THT +DIN41612 connector, type C/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +20 +20 +Connector_DIN +DIN41612_C3_2x10_Male_Horizontal_THT +DIN41612 connector, type C/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +20 +20 +Connector_DIN +DIN41612_C3_3x10_Female_Vertical_THT +DIN41612 connector, type C/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +30 +30 +Connector_DIN +DIN41612_C3_3x10_Male_Horizontal_THT +DIN41612 connector, type C/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +30 +30 +Connector_DIN +DIN41612_C_1x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_1x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x16_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x16_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +64 +64 +Connector_DIN +DIN41612_C_2x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +64 +64 +Connector_DIN +DIN41612_C_3x16_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +48 +48 +Connector_DIN +DIN41612_C_3x16_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +48 +48 +Connector_DIN +DIN41612_C_3x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +96 +96 +Connector_DIN +DIN41612_C_3x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +96 +96 +Connector_DIN +DIN41612_D_2x8_Female_Vertical_THT +DIN41612 connector, type D, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +16 +16 +Connector_DIN +DIN41612_D_2x8_Male_Horizontal_THT +DIN41612 connector, type D, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +16 +16 +Connector_DIN +DIN41612_D_2x16_Female_Vertical_THT +DIN41612 connector, type D, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +32 +32 +Connector_DIN +DIN41612_D_2x16_Male_Horizontal_THT +DIN41612 connector, type D, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_RowsAC_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_RowsAC_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_3x16_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +48 +48 +Connector_DIN +DIN41612_E_3x16_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +48 +48 +Connector_DIN +DIN41612_F_2x16_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_RowsZD_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_RowsZD_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_3x16_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +48 +48 +Connector_DIN +DIN41612_F_3x16_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +48 +48 +Connector_DIN +DIN41612_Q2_2x16_Male_Horizontal_THT +DIN41612 connector, type Q/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/2 +0 +32 +32 +Connector_DIN +DIN41612_Q2_2x16_Male_Vertical_THT +DIN41612 connector, type Q/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/2 +0 +32 +32 +Connector_DIN +DIN41612_Q3_2x10_Male_Horizontal_THT +DIN41612 connector, type Q/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/3 +0 +20 +20 +Connector_DIN +DIN41612_Q3_2x10_Male_Vertical_THT +DIN41612 connector, type Q/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/3 +0 +20 +20 +Connector_DIN +DIN41612_Q_2x32_Male_Horizontal_THT +DIN41612 connector, type Q, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q +0 +64 +64 +Connector_DIN +DIN41612_Q_2x32_Male_Vertical_THT +DIN41612 connector, type Q, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q +0 +64 +64 +Connector_DIN +DIN41612_R2_2x16_Male_Horizontal_THT +DIN41612 connector, type R/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +32 +32 +Connector_DIN +DIN41612_R2_2x16_Male_Vertical_THT +DIN41612 connector, type R/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +32 +32 +Connector_DIN +DIN41612_R2_3x16_Male_Horizontal_THT +DIN41612 connector, type R/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +48 +48 +Connector_DIN +DIN41612_R2_3x16_Male_Vertical_THT +DIN41612 connector, type R/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +48 +48 +Connector_DIN +DIN41612_R3_2x10_Male_Horizontal_THT +DIN41612 connector, type R/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +20 +20 +Connector_DIN +DIN41612_R3_2x10_Male_Vertical_THT +DIN41612 connector, type R/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +20 +20 +Connector_DIN +DIN41612_R3_3x10_Male_Horizontal_THT +DIN41612 connector, type R/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +30 +30 +Connector_DIN +DIN41612_R3_3x10_Male_Vertical_THT +DIN41612 connector, type R/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +30 +30 +Connector_DIN +DIN41612_R_1x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_1x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x16_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x16_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +64 +64 +Connector_DIN +DIN41612_R_2x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +64 +64 +Connector_DIN +DIN41612_R_3x16_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +48 +48 +Connector_DIN +DIN41612_R_3x16_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +48 +48 +Connector_DIN +DIN41612_R_3x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +96 +96 +Connector_DIN +DIN41612_R_3x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +96 +96 +Connector_Dsub +DSUB-9_Female_EdgeMount_P2.77mm +9-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Vertical_P2.77x2.84mm +9-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Vertical_P2.77x2.84mm_MountingHoles +9-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_EdgeMount_P2.77mm +9-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Vertical_P2.77x2.84mm +9-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Vertical_P2.77x2.84mm_MountingHoles +9-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 25mm +0 +11 +10 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 25mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_EdgeMount_P2.77mm +15-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Vertical_P2.77x2.84mm +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Vertical_P2.77x2.84mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_EdgeMount_P2.77mm +15-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Vertical_P2.77x2.84mm +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Vertical_P2.77x2.84mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-25_Female_EdgeMount_P2.77mm +25-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Vertical_P2.77x2.84mm +25-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Vertical_P2.77x2.84mm_MountingHoles +25-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_EdgeMount_P2.77mm +25-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Vertical_P2.77x2.84mm +25-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Vertical_P2.77x2.84mm_MountingHoles +25-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +26-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +26-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-37_Female_EdgeMount_P2.77mm +37-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Vertical_P2.77x2.84mm +37-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Vertical_P2.77x2.84mm_MountingHoles +37-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_EdgeMount_P2.77mm +37-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Vertical_P2.77x2.84mm +37-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Vertical_P2.77x2.84mm_MountingHoles +37-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +44-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +44-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x2.54mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x2.54mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Female_Vertical_P2.41x1.98mm_MountingHoles +62-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.41x1.98mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector straight vertical THT female pitch 2.41x1.98mm mounting holes distance 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x2.54mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x2.54mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Male_Vertical_P2.41x1.98mm_MountingHoles +62-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.41x1.98mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector straight vertical THT male pitch 2.41x1.98mm mounting holes distance 63.5mm +0 +64 +63 +Connector_FFC-FPC +Hirose_FH12-6S-0.5SH_1x06-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-6S-0.5SH, 6 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +8 +7 +Connector_FFC-FPC +Hirose_FH12-8S-0.5SH_1x08-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-8S-0.5SH, 8 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +10 +9 +Connector_FFC-FPC +Hirose_FH12-10S-0.5SH_1x10-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-10S-0.5SH, 10 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +12 +11 +Connector_FFC-FPC +Hirose_FH12-11S-0.5SH_1x11-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-11S-0.5SH, 11 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +13 +12 +Connector_FFC-FPC +Hirose_FH12-12S-0.5SH_1x12-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-12S-0.5SH, 12 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +14 +13 +Connector_FFC-FPC +Hirose_FH12-13S-0.5SH_1x13-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-13S-0.5SH, 13 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +15 +14 +Connector_FFC-FPC +Hirose_FH12-14S-0.5SH_1x14-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-14S-0.5SH, 14 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +16 +15 +Connector_FFC-FPC +Hirose_FH12-15S-0.5SH_1x15-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-15S-0.5SH, 15 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +17 +16 +Connector_FFC-FPC +Hirose_FH12-16S-0.5SH_1x16-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-16S-0.5SH, 16 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +18 +17 +Connector_FFC-FPC +Hirose_FH12-17S-0.5SH_1x17-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-17S-0.5SH, 17 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +19 +18 +Connector_FFC-FPC +Hirose_FH12-18S-0.5SH_1x18-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-18S-0.5SH, 18 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +20 +19 +Connector_FFC-FPC +Hirose_FH12-19S-0.5SH_1x19-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-19S-0.5SH, 19 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +21 +20 +Connector_FFC-FPC +Hirose_FH12-20S-0.5SH_1x20-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-20S-0.5SH, 20 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +22 +21 +Connector_FFC-FPC +Hirose_FH12-22S-0.5SH_1x22-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-22S-0.5SH, 22 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +24 +23 +Connector_FFC-FPC +Hirose_FH12-24S-0.5SH_1x24-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-24S-0.5SH, 24 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +26 +25 +Connector_FFC-FPC +Hirose_FH12-25S-0.5SH_1x25-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-25S-0.5SH, 25 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +27 +26 +Connector_FFC-FPC +Hirose_FH12-26S-0.5SH_1x26-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-26S-0.5SH, 26 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +28 +27 +Connector_FFC-FPC +Hirose_FH12-28S-0.5SH_1x28-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-28S-0.5SH, 28 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +30 +29 +Connector_FFC-FPC +Hirose_FH12-30S-0.5SH_1x30-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-30S-0.5SH, 30 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +32 +31 +Connector_FFC-FPC +Hirose_FH12-32S-0.5SH_1x32-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-32S-0.5SH, 32 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +34 +33 +Connector_FFC-FPC +Hirose_FH12-33S-0.5SH_1x33-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-33S-0.5SH, 33 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +35 +34 +Connector_FFC-FPC +Hirose_FH12-34S-0.5SH_1x34-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-34S-0.5SH, 34 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +36 +35 +Connector_FFC-FPC +Hirose_FH12-35S-0.5SH_1x35-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-35S-0.5SH, 35 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +37 +36 +Connector_FFC-FPC +Hirose_FH12-36S-0.5SH_1x36-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-36S-0.5SH, 36 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +38 +37 +Connector_FFC-FPC +Hirose_FH12-40S-0.5SH_1x40-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-40S-0.5SH, 40 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +42 +41 +Connector_FFC-FPC +Hirose_FH12-45S-0.5SH_1x45-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-45S-0.5SH, 45 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +47 +46 +Connector_FFC-FPC +Hirose_FH12-50S-0.5SH_1x50-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-50S-0.5SH, 50 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +52 +51 +Connector_FFC-FPC +Hirose_FH12-53S-0.5SH_1x53-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-53S-0.5SH, 53 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +55 +54 +Connector_FFC-FPC +JAE_FF0825SA1_2Rows-25Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0825SA1, 25 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +25 +25 +Connector_FFC-FPC +JAE_FF0829SA1_2Rows-29Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0829SA1, 29 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +29 +29 +Connector_FFC-FPC +JAE_FF0841SA1_2Rows-41Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0841SA1, 41 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +41 +41 +Connector_FFC-FPC +JAE_FF0851SA1_2Rows-51Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0851SA1, 51 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +51 +51 +Connector_FFC-FPC +JAE_FF0871SA1_2Rows-71Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0871SA1, 71 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +71 +71 +Connector_FFC-FPC +JAE_FF0881SA1_2Rows-81Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0881SA1, 81 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +81 +81 +Connector_FFC-FPC +Molex_54132-5033_1x50-1MP_P0.5mm_Horizontal +Molex FFC/FPC connector, 50 bottom-side contacts, 0.5mm pitch, 2.0mm height, https://www.molex.com/pdm_docs/sd/541325033_sd.pdf +FFC FPC +0 +54 +51 +Connector_FFC-FPC +Molex_200528-0040_1x04-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0040, 4 Circuits (https://www.molex.com/pdm_docs/sd/2005280040_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +6 +5 +Connector_FFC-FPC +Molex_200528-0050_1x05-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0050, 5 Circuits (https://www.molex.com/pdm_docs/sd/2005280050_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +7 +6 +Connector_FFC-FPC +Molex_200528-0060_1x06-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0060, 6 Circuits (https://www.molex.com/pdm_docs/sd/2005280060_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +8 +7 +Connector_FFC-FPC +Molex_200528-0070_1x07-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0070, 7 Circuits (https://www.molex.com/pdm_docs/sd/2005280070_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +9 +8 +Connector_FFC-FPC +Molex_200528-0080_1x08-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0080, 8 Circuits (https://www.molex.com/pdm_docs/sd/2005280080_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +10 +9 +Connector_FFC-FPC +Molex_200528-0090_1x09-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0090, 9 Circuits (https://www.molex.com/pdm_docs/sd/2005280090_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +11 +10 +Connector_FFC-FPC +Molex_200528-0100_1x10-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0100, 10 Circuits (https://www.molex.com/pdm_docs/sd/2005280100_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +12 +11 +Connector_FFC-FPC +Molex_200528-0110_1x11-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0110, 11 Circuits (https://www.molex.com/pdm_docs/sd/2005280110_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +13 +12 +Connector_FFC-FPC +Molex_200528-0120_1x12-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0120, 12 Circuits (https://www.molex.com/pdm_docs/sd/2005280120_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +14 +13 +Connector_FFC-FPC +Molex_200528-0130_1x13-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0130, 13 Circuits (https://www.molex.com/pdm_docs/sd/2005280130_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +15 +14 +Connector_FFC-FPC +Molex_200528-0140_1x14-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0140, 14 Circuits (https://www.molex.com/pdm_docs/sd/2005280140_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +16 +15 +Connector_FFC-FPC +Molex_200528-0150_1x15-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0150, 15 Circuits (https://www.molex.com/pdm_docs/sd/2005280150_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +17 +16 +Connector_FFC-FPC +Molex_200528-0160_1x16-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0160, 16 Circuits (https://www.molex.com/pdm_docs/sd/2005280160_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +18 +17 +Connector_FFC-FPC +Molex_200528-0170_1x17-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0170, 17 Circuits (https://www.molex.com/pdm_docs/sd/2005280170_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +19 +18 +Connector_FFC-FPC +Molex_200528-0180_1x18-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0180, 18 Circuits (https://www.molex.com/pdm_docs/sd/2005280180_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +20 +19 +Connector_FFC-FPC +Molex_200528-0190_1x19-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0190, 19 Circuits (https://www.molex.com/pdm_docs/sd/2005280190_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +21 +20 +Connector_FFC-FPC +Molex_200528-0200_1x20-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0200, 20 Circuits (https://www.molex.com/pdm_docs/sd/2005280200_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +22 +21 +Connector_FFC-FPC +Molex_200528-0210_1x21-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0210, 21 Circuits (https://www.molex.com/pdm_docs/sd/2005280210_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +23 +22 +Connector_FFC-FPC +Molex_200528-0220_1x22-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0220, 22 Circuits (https://www.molex.com/pdm_docs/sd/2005280220_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +24 +23 +Connector_FFC-FPC +Molex_200528-0230_1x23-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0230, 23 Circuits (https://www.molex.com/pdm_docs/sd/2005280230_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +25 +24 +Connector_FFC-FPC +Molex_200528-0240_1x24-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0240, 24 Circuits (https://www.molex.com/pdm_docs/sd/2005280240_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +26 +25 +Connector_FFC-FPC +Molex_200528-0250_1x25-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0250, 25 Circuits (https://www.molex.com/pdm_docs/sd/2005280250_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +27 +26 +Connector_FFC-FPC +Molex_200528-0260_1x26-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0260, 26 Circuits (https://www.molex.com/pdm_docs/sd/2005280260_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +28 +27 +Connector_FFC-FPC +Molex_200528-0270_1x27-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0270, 27 Circuits (https://www.molex.com/pdm_docs/sd/2005280270_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +29 +28 +Connector_FFC-FPC +Molex_200528-0280_1x28-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0280, 28 Circuits (https://www.molex.com/pdm_docs/sd/2005280280_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +30 +29 +Connector_FFC-FPC +Molex_200528-0290_1x29-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0290, 29 Circuits (https://www.molex.com/pdm_docs/sd/2005280290_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +31 +30 +Connector_FFC-FPC +Molex_200528-0300_1x30-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0300, 30 Circuits (https://www.molex.com/pdm_docs/sd/2005280300_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +32 +31 +Connector_FFC-FPC +Molex_502231-1500_1x15-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 15 Circuits (https://www.molex.com/pdm_docs/sd/5022311500_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +17 +16 +Connector_FFC-FPC +Molex_502231-2400_1x24-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 24 Circuits (https://www.molex.com/pdm_docs/sd/5022312400_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +26 +25 +Connector_FFC-FPC +Molex_502231-3300_1x33-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 33 Circuits (https://www.molex.com/pdm_docs/sd/5022313300_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +36 +34 +Connector_FFC-FPC +Molex_502244-1530_1x15-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 15 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +19 +16 +Connector_FFC-FPC +Molex_502244-2430_1x24-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 24 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +28 +25 +Connector_FFC-FPC +Molex_502244-3330_1x33-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 33 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +39 +34 +Connector_FFC-FPC +Molex_502250-1791_2Rows-17Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-1791, 17 Circuits (http://www.molex.com/pdm_docs/sd/5022501791_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +19 +18 +Connector_FFC-FPC +Molex_502250-2191_2Rows-21Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2191, 21 Circuits (http://www.molex.com/pdm_docs/sd/5022502191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +23 +22 +Connector_FFC-FPC +Molex_502250-2391_2Rows-23Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2391, 23 Circuits (http://www.molex.com/pdm_docs/sd/5022502391_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +25 +24 +Connector_FFC-FPC +Molex_502250-2791_2Rows-27Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2791, 27 Circuits (http://www.molex.com/pdm_docs/sd/5022502791_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +29 +28 +Connector_FFC-FPC +Molex_502250-3391_2Rows-33Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3391, 33 Circuits (http://www.molex.com/pdm_docs/sd/5022503391_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +35 +34 +Connector_FFC-FPC +Molex_502250-3591_2Rows-35Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3591, 35 Circuits (http://www.molex.com/pdm_docs/sd/5022503591_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +37 +36 +Connector_FFC-FPC +Molex_502250-3991_2Rows-39Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3991, 39 Circuits (http://www.molex.com/pdm_docs/sd/5022503991_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +41 +40 +Connector_FFC-FPC +Molex_502250-4191_2Rows-41Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-4191, 41 Circuits (http://www.molex.com/pdm_docs/sd/5022504191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +43 +42 +Connector_FFC-FPC +Molex_502250-5191_2Rows-51Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-5191, 51 Circuits (http://www.molex.com/pdm_docs/sd/5022505191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +53 +52 +Connector_FFC-FPC +TE_0-1734839-5_1x05-1MP_P0.5mm_Horizontal +TE FPC connector, 05 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +7 +6 +Connector_FFC-FPC +TE_0-1734839-6_1x06-1MP_P0.5mm_Horizontal +TE FPC connector, 06 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +8 +7 +Connector_FFC-FPC +TE_0-1734839-7_1x07-1MP_P0.5mm_Horizontal +TE FPC connector, 07 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +9 +8 +Connector_FFC-FPC +TE_0-1734839-8_1x08-1MP_P0.5mm_Horizontal +TE FPC connector, 08 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +10 +9 +Connector_FFC-FPC +TE_0-1734839-9_1x09-1MP_P0.5mm_Horizontal +TE FPC connector, 09 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +11 +10 +Connector_FFC-FPC +TE_1-84952-0_1x10-1MP_P1.0mm_Horizontal +TE FPC connector, 10 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +12 +11 +Connector_FFC-FPC +TE_1-84952-1_1x11-1MP_P1.0mm_Horizontal +TE FPC connector, 11 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +13 +12 +Connector_FFC-FPC +TE_1-84952-2_1x12-1MP_P1.0mm_Horizontal +TE FPC connector, 12 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +14 +13 +Connector_FFC-FPC +TE_1-84952-3_1x13-1MP_P1.0mm_Horizontal +TE FPC connector, 13 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +15 +14 +Connector_FFC-FPC +TE_1-84952-4_1x14-1MP_P1.0mm_Horizontal +TE FPC connector, 14 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +16 +15 +Connector_FFC-FPC +TE_1-84952-5_1x15-1MP_P1.0mm_Horizontal +TE FPC connector, 15 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +17 +16 +Connector_FFC-FPC +TE_1-84952-6_1x16-1MP_P1.0mm_Horizontal +TE FPC connector, 16 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +18 +17 +Connector_FFC-FPC +TE_1-84952-7_1x17-1MP_P1.0mm_Horizontal +TE FPC connector, 17 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +19 +18 +Connector_FFC-FPC +TE_1-84952-8_1x18-1MP_P1.0mm_Horizontal +TE FPC connector, 18 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +20 +19 +Connector_FFC-FPC +TE_1-84952-9_1x19-1MP_P1.0mm_Horizontal +TE FPC connector, 19 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +21 +20 +Connector_FFC-FPC +TE_1-84953-0_1x10-1MP_P1.0mm_Horizontal +TE FPC connector, 10 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +12 +11 +Connector_FFC-FPC +TE_1-84953-1_1x11-1MP_P1.0mm_Horizontal +TE FPC connector, 11 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +13 +12 +Connector_FFC-FPC +TE_1-84953-2_1x12-1MP_P1.0mm_Horizontal +TE FPC connector, 12 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +14 +13 +Connector_FFC-FPC +TE_1-84953-3_1x13-1MP_P1.0mm_Horizontal +TE FPC connector, 13 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +15 +14 +Connector_FFC-FPC +TE_1-84953-4_1x14-1MP_P1.0mm_Horizontal +TE FPC connector, 14 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +16 +15 +Connector_FFC-FPC +TE_1-84953-5_1x15-1MP_P1.0mm_Horizontal +TE FPC connector, 15 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +17 +16 +Connector_FFC-FPC +TE_1-84953-6_1x16-1MP_P1.0mm_Horizontal +TE FPC connector, 16 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +18 +17 +Connector_FFC-FPC +TE_1-84953-7_1x17-1MP_P1.0mm_Horizontal +TE FPC connector, 17 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +19 +18 +Connector_FFC-FPC +TE_1-84953-8_1x18-1MP_P1.0mm_Horizontal +TE FPC connector, 18 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +20 +19 +Connector_FFC-FPC +TE_1-84953-9_1x19-1MP_P1.0mm_Horizontal +TE FPC connector, 19 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +21 +20 +Connector_FFC-FPC +TE_1-1734839-0_1x10-1MP_P0.5mm_Horizontal +TE FPC connector, 10 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +12 +11 +Connector_FFC-FPC +TE_1-1734839-1_1x11-1MP_P0.5mm_Horizontal +TE FPC connector, 11 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +13 +12 +Connector_FFC-FPC +TE_1-1734839-2_1x12-1MP_P0.5mm_Horizontal +TE FPC connector, 12 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +14 +13 +Connector_FFC-FPC +TE_1-1734839-3_1x13-1MP_P0.5mm_Horizontal +TE FPC connector, 13 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +15 +14 +Connector_FFC-FPC +TE_1-1734839-4_1x14-1MP_P0.5mm_Horizontal +TE FPC connector, 14 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +16 +15 +Connector_FFC-FPC +TE_1-1734839-5_1x15-1MP_P0.5mm_Horizontal +TE FPC connector, 15 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +17 +16 +Connector_FFC-FPC +TE_1-1734839-6_1x16-1MP_P0.5mm_Horizontal +TE FPC connector, 16 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +18 +17 +Connector_FFC-FPC +TE_1-1734839-7_1x17-1MP_P0.5mm_Horizontal +TE FPC connector, 17 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +19 +18 +Connector_FFC-FPC +TE_1-1734839-8_1x18-1MP_P0.5mm_Horizontal +TE FPC connector, 18 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +20 +19 +Connector_FFC-FPC +TE_1-1734839-9_1x19-1MP_P0.5mm_Horizontal +TE FPC connector, 19 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +21 +20 +Connector_FFC-FPC +TE_2-84952-0_1x20-1MP_P1.0mm_Horizontal +TE FPC connector, 20 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +22 +21 +Connector_FFC-FPC +TE_2-84952-1_1x21-1MP_P1.0mm_Horizontal +TE FPC connector, 21 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +23 +22 +Connector_FFC-FPC +TE_2-84952-2_1x22-1MP_P1.0mm_Horizontal +TE FPC connector, 22 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +24 +23 +Connector_FFC-FPC +TE_2-84952-3_1x23-1MP_P1.0mm_Horizontal +TE FPC connector, 23 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +25 +24 +Connector_FFC-FPC +TE_2-84952-4_1x24-1MP_P1.0mm_Horizontal +TE FPC connector, 24 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +26 +25 +Connector_FFC-FPC +TE_2-84952-5_1x25-1MP_P1.0mm_Horizontal +TE FPC connector, 25 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +27 +26 +Connector_FFC-FPC +TE_2-84952-6_1x26-1MP_P1.0mm_Horizontal +TE FPC connector, 26 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +28 +27 +Connector_FFC-FPC +TE_2-84952-7_1x27-1MP_P1.0mm_Horizontal +TE FPC connector, 27 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +29 +28 +Connector_FFC-FPC +TE_2-84952-8_1x28-1MP_P1.0mm_Horizontal +TE FPC connector, 28 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +30 +29 +Connector_FFC-FPC +TE_2-84952-9_1x29-1MP_P1.0mm_Horizontal +TE FPC connector, 29 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +31 +30 +Connector_FFC-FPC +TE_2-84953-0_1x20-1MP_P1.0mm_Horizontal +TE FPC connector, 20 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +22 +21 +Connector_FFC-FPC +TE_2-84953-1_1x21-1MP_P1.0mm_Horizontal +TE FPC connector, 21 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +23 +22 +Connector_FFC-FPC +TE_2-84953-2_1x22-1MP_P1.0mm_Horizontal +TE FPC connector, 22 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +24 +23 +Connector_FFC-FPC +TE_2-84953-3_1x23-1MP_P1.0mm_Horizontal +TE FPC connector, 23 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +25 +24 +Connector_FFC-FPC +TE_2-84953-4_1x24-1MP_P1.0mm_Horizontal +TE FPC connector, 24 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +26 +25 +Connector_FFC-FPC +TE_2-84953-5_1x25-1MP_P1.0mm_Horizontal +TE FPC connector, 25 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +27 +26 +Connector_FFC-FPC +TE_2-84953-6_1x26-1MP_P1.0mm_Horizontal +TE FPC connector, 26 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +28 +27 +Connector_FFC-FPC +TE_2-84953-7_1x27-1MP_P1.0mm_Horizontal +TE FPC connector, 27 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +29 +28 +Connector_FFC-FPC +TE_2-84953-8_1x28-1MP_P1.0mm_Horizontal +TE FPC connector, 28 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +30 +29 +Connector_FFC-FPC +TE_2-84953-9_1x29-1MP_P1.0mm_Horizontal +TE FPC connector, 29 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +31 +30 +Connector_FFC-FPC +TE_2-1734839-0_1x20-1MP_P0.5mm_Horizontal +TE FPC connector, 20 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +22 +21 +Connector_FFC-FPC +TE_2-1734839-1_1x21-1MP_P0.5mm_Horizontal +TE FPC connector, 21 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +23 +22 +Connector_FFC-FPC +TE_2-1734839-2_1x22-1MP_P0.5mm_Horizontal +TE FPC connector, 22 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +24 +23 +Connector_FFC-FPC +TE_2-1734839-3_1x23-1MP_P0.5mm_Horizontal +TE FPC connector, 23 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +25 +24 +Connector_FFC-FPC +TE_2-1734839-4_1x24-1MP_P0.5mm_Horizontal +TE FPC connector, 24 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +26 +25 +Connector_FFC-FPC +TE_2-1734839-5_1x25-1MP_P0.5mm_Horizontal +TE FPC connector, 25 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +27 +26 +Connector_FFC-FPC +TE_2-1734839-6_1x26-1MP_P0.5mm_Horizontal +TE FPC connector, 26 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +28 +27 +Connector_FFC-FPC +TE_2-1734839-7_1x27-1MP_P0.5mm_Horizontal +TE FPC connector, 27 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +29 +28 +Connector_FFC-FPC +TE_2-1734839-8_1x28-1MP_P0.5mm_Horizontal +TE FPC connector, 28 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +30 +29 +Connector_FFC-FPC +TE_2-1734839-9_1x29-1MP_P0.5mm_Horizontal +TE FPC connector, 29 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +31 +30 +Connector_FFC-FPC +TE_3-84952-0_1x30-1MP_P1.0mm_Horizontal +TE FPC connector, 30 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +32 +31 +Connector_FFC-FPC +TE_3-84953-0_1x30-1MP_P1.0mm_Horizontal +TE FPC connector, 30 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +32 +31 +Connector_FFC-FPC +TE_3-1734839-0_1x30-1MP_P0.5mm_Horizontal +TE FPC connector, 30 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +32 +31 +Connector_FFC-FPC +TE_3-1734839-1_1x31-1MP_P0.5mm_Horizontal +TE FPC connector, 31 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +33 +32 +Connector_FFC-FPC +TE_3-1734839-2_1x32-1MP_P0.5mm_Horizontal +TE FPC connector, 32 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +34 +33 +Connector_FFC-FPC +TE_3-1734839-3_1x33-1MP_P0.5mm_Horizontal +TE FPC connector, 33 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +35 +34 +Connector_FFC-FPC +TE_3-1734839-4_1x34-1MP_P0.5mm_Horizontal +TE FPC connector, 34 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +36 +35 +Connector_FFC-FPC +TE_3-1734839-5_1x35-1MP_P0.5mm_Horizontal +TE FPC connector, 35 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +37 +36 +Connector_FFC-FPC +TE_3-1734839-6_1x36-1MP_P0.5mm_Horizontal +TE FPC connector, 36 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +38 +37 +Connector_FFC-FPC +TE_3-1734839-7_1x37-1MP_P0.5mm_Horizontal +TE FPC connector, 37 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +39 +38 +Connector_FFC-FPC +TE_3-1734839-8_1x38-1MP_P0.5mm_Horizontal +TE FPC connector, 38 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +40 +39 +Connector_FFC-FPC +TE_3-1734839-9_1x39-1MP_P0.5mm_Horizontal +TE FPC connector, 39 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +41 +40 +Connector_FFC-FPC +TE_4-1734839-0_1x40-1MP_P0.5mm_Horizontal +TE FPC connector, 40 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +42 +41 +Connector_FFC-FPC +TE_4-1734839-1_1x41-1MP_P0.5mm_Horizontal +TE FPC connector, 41 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +43 +42 +Connector_FFC-FPC +TE_4-1734839-2_1x42-1MP_P0.5mm_Horizontal +TE FPC connector, 42 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +44 +43 +Connector_FFC-FPC +TE_4-1734839-3_1x43-1MP_P0.5mm_Horizontal +TE FPC connector, 43 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +45 +44 +Connector_FFC-FPC +TE_4-1734839-4_1x44-1MP_P0.5mm_Horizontal +TE FPC connector, 44 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +46 +45 +Connector_FFC-FPC +TE_4-1734839-5_1x45-1MP_P0.5mm_Horizontal +TE FPC connector, 45 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +47 +46 +Connector_FFC-FPC +TE_4-1734839-6_1x46-1MP_P0.5mm_Horizontal +TE FPC connector, 46 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +48 +47 +Connector_FFC-FPC +TE_4-1734839-7_1x47-1MP_P0.5mm_Horizontal +TE FPC connector, 47 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +49 +48 +Connector_FFC-FPC +TE_4-1734839-8_1x48-1MP_P0.5mm_Horizontal +TE FPC connector, 48 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +50 +49 +Connector_FFC-FPC +TE_4-1734839-9_1x49-1MP_P0.5mm_Horizontal +TE FPC connector, 49 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +51 +50 +Connector_FFC-FPC +TE_5-1734839-0_1x50-1MP_P0.5mm_Horizontal +TE FPC connector, 50 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +52 +51 +Connector_FFC-FPC +TE_84952-4_1x04-1MP_P1.0mm_Horizontal +TE FPC connector, 04 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +6 +5 +Connector_FFC-FPC +TE_84952-5_1x05-1MP_P1.0mm_Horizontal +TE FPC connector, 05 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +7 +6 +Connector_FFC-FPC +TE_84952-6_1x06-1MP_P1.0mm_Horizontal +TE FPC connector, 06 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +8 +7 +Connector_FFC-FPC +TE_84952-7_1x07-1MP_P1.0mm_Horizontal +TE FPC connector, 07 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +9 +8 +Connector_FFC-FPC +TE_84952-8_1x08-1MP_P1.0mm_Horizontal +TE FPC connector, 08 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +10 +9 +Connector_FFC-FPC +TE_84952-9_1x09-1MP_P1.0mm_Horizontal +TE FPC connector, 09 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +11 +10 +Connector_FFC-FPC +TE_84953-4_1x04-1MP_P1.0mm_Horizontal +TE FPC connector, 04 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +6 +5 +Connector_FFC-FPC +TE_84953-5_1x05-1MP_P1.0mm_Horizontal +TE FPC connector, 05 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +7 +6 +Connector_FFC-FPC +TE_84953-6_1x06-1MP_P1.0mm_Horizontal +TE FPC connector, 06 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +8 +7 +Connector_FFC-FPC +TE_84953-7_1x07-1MP_P1.0mm_Horizontal +TE FPC connector, 07 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +9 +8 +Connector_FFC-FPC +TE_84953-8_1x08-1MP_P1.0mm_Horizontal +TE FPC connector, 08 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +10 +9 +Connector_FFC-FPC +TE_84953-9_1x09-1MP_P1.0mm_Horizontal +TE FPC connector, 09 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +11 +10 +Connector_FFC-FPC +Wuerth_68611214422_1x12-1MP_P1.0mm_Horizontal +http://katalog.we-online.de/em/datasheet/68611214422.pdf +Wuerth FPC 68611214422 connector 12 bottom-side contacts 1.0mm pitch 1.0mm height SMT +0 +14 +13 +Connector_HDMI +HDMI_A_Contact_Technology_HDMI-19APL2_Horizontal +HDMI Contact Technology Type A http://www.contactswitch.com/en/download.aspx?id=1449 +HDMI Contact Technology Type A +0 +23 +20 +Connector_HDMI +HDMI_A_Kycon_KDMIX-SL1-NS-WS-B15_VerticalRightAngle +HDMI, Type A, Kycon KDMIX-SL1-NS-WS-B15, Vertical Right Angle, http://www.kycon.com/Pub_Eng_Draw/KDMIX-SL1-NS-WS-B15.pdf +hdmi type a +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-0x01 +HDMI, Micro, Type D, SMD, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle smd +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-1x01 +HDMI, Micro, Type D, THT, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle tht +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-2x0x +HDMI, Micro, Type D, THT/SMD hybrid, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle tht smd hybrid +0 +23 +20 +Connector_Harwin +Harwin_Gecko-G125-FVX0605L0X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row female, vertical entry, PN:G125-FVX0605L0X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-FVX1005L0X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row female, vertical entry, PN:G125-FVX1005L0X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-FVX1205L0X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row female, vertical entry, PN:G125-FVX1205L0X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-FVX1605L0X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row female, vertical entry, PN:G125-FVX1605L0X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-FVX2005L0X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row female, vertical entry, PN:G125-FVX2005L0X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-FVX2605L0X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row female, vertical entry, PN:G125-FVX2605L0X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-FVX3405L0X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row female, vertical entry, PN:G125-FVX3405L0X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-FVX5005L0X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row female, vertical entry, PN:G125-FVX5005L0X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_Gecko-G125-MVX0605L0X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row male, vertical entry, no latches, PN:G125-MVX0605L0X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-MVX0605L1X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row male, vertical entry, with latches, PN:G125-MVX0605L1X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-MVX1005L0X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row male, vertical entry, no latches, PN:G125-MVX1005L0X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-MVX1005L1X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row male, vertical entry, with latches, PN:G125-MVX1005L1X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-MVX1205L0X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row male, vertical entry, no latches, PN:G125-MVX1205L0X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-MVX1205L1X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row male, vertical entry, with latches, PN:G125-MVX1205L1X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-MVX1605L0X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row male, vertical entry, no latches, PN:G125-MVX1605L0X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-MVX1605L1X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row male, vertical entry, with latches, PN:G125-MVX1605L1X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-MVX2005L0X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row male, vertical entry, no latches, PN:G125-MVX2005L0X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-MVX2005L1X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row male, vertical entry, with latches, PN:G125-MVX2005L1X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-MVX2605L0X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row male, vertical entry, no latches, PN:G125-MVX2605L0X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-MVX2605L1X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row male, vertical entry, with latches, PN:G125-MVX2605L1X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-MVX3405L0X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row male, vertical entry, no latches, PN:G125-MVX3405L0X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-MVX3405L1X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row male, vertical entry, with latches, PN:G125-MVX3405L1X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-MVX5005L0X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row male, vertical entry, no latches, PN:G125-MVX5005L0X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_Gecko-G125-MVX5005L1X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row male, vertical entry, with latches, PN:G125-MVX5005L1X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_LTek-Male_02_P2.00mm_Vertical +Harwin LTek Connector, 2 pins, single row male, vertical entry +connector harwin ltek M80 +0 +2 +2 +Connector_Harwin +Harwin_LTek-Male_02_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 2 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +6 +2 +Connector_Harwin +Harwin_LTek-Male_2x02_P2.00mm_Vertical +Harwin LTek Connector, 4 pins, single row male, vertical entry +connector harwin ltek M80 +0 +4 +4 +Connector_Harwin +Harwin_LTek-Male_2x02_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 4 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +8 +4 +Connector_Harwin +Harwin_LTek-Male_2x03_P2.00mm_Vertical +Harwin LTek Connector, 6 pins, single row male, vertical entry +connector harwin ltek M80 +0 +6 +6 +Connector_Harwin +Harwin_LTek-Male_2x03_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 6 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +10 +6 +Connector_Harwin +Harwin_LTek-Male_2x04_P2.00mm_Vertical +Harwin LTek Connector, 8 pins, single row male, vertical entry +connector harwin ltek M80 +0 +8 +8 +Connector_Harwin +Harwin_LTek-Male_2x04_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 8 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +12 +8 +Connector_Harwin +Harwin_LTek-Male_2x05_P2.00mm_Vertical +Harwin LTek Connector, 10 pins, single row male, vertical entry +connector harwin ltek M80 +0 +10 +10 +Connector_Harwin +Harwin_LTek-Male_2x05_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 10 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +14 +10 +Connector_Harwin +Harwin_LTek-Male_2x06_P2.00mm_Vertical +Harwin LTek Connector, 12 pins, single row male, vertical entry +connector harwin ltek M80 +0 +12 +12 +Connector_Harwin +Harwin_LTek-Male_2x06_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 12 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +16 +12 +Connector_Harwin +Harwin_LTek-Male_2x07_P2.00mm_Vertical +Harwin LTek Connector, 14 pins, single row male, vertical entry +connector harwin ltek M80 +0 +14 +14 +Connector_Harwin +Harwin_LTek-Male_2x07_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 14 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +18 +14 +Connector_Harwin +Harwin_LTek-Male_2x08_P2.00mm_Vertical +Harwin LTek Connector, 16 pins, single row male, vertical entry +connector harwin ltek M80 +0 +16 +16 +Connector_Harwin +Harwin_LTek-Male_2x08_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 16 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +20 +16 +Connector_Harwin +Harwin_LTek-Male_2x09_P2.00mm_Vertical +Harwin LTek Connector, 18 pins, single row male, vertical entry +connector harwin ltek M80 +0 +18 +18 +Connector_Harwin +Harwin_LTek-Male_2x09_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 18 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +22 +18 +Connector_Harwin +Harwin_LTek-Male_2x10_P2.00mm_Vertical +Harwin LTek Connector, 20 pins, single row male, vertical entry +connector harwin ltek M80 +0 +20 +20 +Connector_Harwin +Harwin_LTek-Male_2x10_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 20 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +24 +20 +Connector_Harwin +Harwin_LTek-Male_2x13_P2.00mm_Vertical +Harwin LTek Connector, 26 pins, single row male, vertical entry +connector harwin ltek M80 +0 +26 +26 +Connector_Harwin +Harwin_LTek-Male_2x13_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 26 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +30 +26 +Connector_Harwin +Harwin_LTek-Male_2x17_P2.00mm_Vertical +Harwin LTek Connector, 34 pins, single row male, vertical entry +connector harwin ltek M80 +0 +34 +34 +Connector_Harwin +Harwin_LTek-Male_2x17_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 34 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +38 +34 +Connector_Harwin +Harwin_LTek-Male_2x22_P2.00mm_Vertical +Harwin LTek Connector, 44 pins, single row male, vertical entry +connector harwin ltek M80 +0 +44 +44 +Connector_Harwin +Harwin_LTek-Male_2x22_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 44 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +48 +44 +Connector_Harwin +Harwin_LTek-Male_03_P2.00mm_Vertical +Harwin LTek Connector, 3 pins, single row male, vertical entry +connector harwin ltek M80 +0 +3 +3 +Connector_Harwin +Harwin_LTek-Male_03_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 3 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +7 +3 +Connector_Harwin +Harwin_LTek-Male_04_P2.00mm_Vertical +Harwin LTek Connector, 4 pins, single row male, vertical entry +connector harwin ltek M80 +0 +4 +4 +Connector_Harwin +Harwin_LTek-Male_04_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 4 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +8 +4 +Connector_Harwin +Harwin_LTek-Male_05_P2.00mm_Vertical +Harwin LTek Connector, 5 pins, single row male, vertical entry +connector harwin ltek M80 +0 +5 +5 +Connector_Harwin +Harwin_LTek-Male_05_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 5 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +9 +5 +Connector_Harwin +Harwin_LTek-Male_06_P2.00mm_Vertical +Harwin LTek Connector, 6 pins, single row male, vertical entry +connector harwin ltek M80 +0 +6 +6 +Connector_Harwin +Harwin_LTek-Male_06_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 6 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +10 +6 +Connector_Harwin +Harwin_LTek-Male_07_P2.00mm_Vertical +Harwin LTek Connector, 7 pins, single row male, vertical entry +connector harwin ltek M80 +0 +7 +7 +Connector_Harwin +Harwin_LTek-Male_07_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 7 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +11 +7 +Connector_Harwin +Harwin_LTek-Male_17_P2.00mm_Vertical +Harwin LTek Connector, 17 pins, single row male, vertical entry +connector harwin ltek M80 +0 +17 +17 +Connector_Harwin +Harwin_LTek-Male_17_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 17 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +21 +17 +Connector_Harwin +Harwin_LTek-Male_22_P2.00mm_Vertical +Harwin LTek Connector, 22 pins, single row male, vertical entry +connector harwin ltek M80 +0 +22 +22 +Connector_Harwin +Harwin_LTek-Male_22_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 22 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +26 +22 +Connector_Harwin +Harwin_M20-89003xx_1x03_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89003xx, 3 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +4 +3 +Connector_Harwin +Harwin_M20-89004xx_1x04_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89004xx, 4 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +5 +4 +Connector_Harwin +Harwin_M20-89005xx_1x05_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89005xx, 5 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +6 +5 +Connector_Harwin +Harwin_M20-89006xx_1x06_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89006xx, 6 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +7 +6 +Connector_Harwin +Harwin_M20-89007xx_1x07_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89007xx, 7 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +8 +7 +Connector_Harwin +Harwin_M20-89008xx_1x08_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89008xx, 8 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +9 +8 +Connector_Harwin +Harwin_M20-89009xx_1x09_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89009xx, 9 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +10 +9 +Connector_Harwin +Harwin_M20-89010xx_1x10_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89010xx, 10 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +11 +10 +Connector_Harwin +Harwin_M20-89011xx_1x11_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89011xx, 11 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +12 +11 +Connector_Harwin +Harwin_M20-89012xx_1x12_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89012xx, 12 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +13 +12 +Connector_Harwin +Harwin_M20-89013xx_1x13_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89013xx, 13 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +14 +13 +Connector_Harwin +Harwin_M20-89014xx_1x14_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89014xx, 14 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +15 +14 +Connector_Harwin +Harwin_M20-89015xx_1x15_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89015xx, 15 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +16 +15 +Connector_Harwin +Harwin_M20-89016xx_1x16_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89016xx, 16 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +17 +16 +Connector_Harwin +Harwin_M20-89017xx_1x17_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89017xx, 17 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +18 +17 +Connector_Harwin +Harwin_M20-89018xx_1x18_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89018xx, 18 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +19 +18 +Connector_Harwin +Harwin_M20-89019xx_1x19_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89019xx, 19 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +20 +19 +Connector_Harwin +Harwin_M20-89020xx_1x20_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89020xx, 20 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +21 +20 +Connector_Harwin +Harwin_M20-7810245_2x02_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810245, 2 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +4 +4 +Connector_Harwin +Harwin_M20-7810345_2x03_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810345, 3 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +6 +6 +Connector_Harwin +Harwin_M20-7810445_2x04_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810445, 4 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +8 +8 +Connector_Harwin +Harwin_M20-7810545_2x05_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810545, 5 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +10 +10 +Connector_Harwin +Harwin_M20-7810645_2x06_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810645, 6 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +12 +12 +Connector_Harwin +Harwin_M20-7810745_2x07_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810745, 7 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +14 +14 +Connector_Harwin +Harwin_M20-7810845_2x08_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810845, 8 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +16 +16 +Connector_Harwin +Harwin_M20-7810945_2x09_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810945, 9 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +18 +18 +Connector_Harwin +Harwin_M20-7811045_2x10_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811045, 10 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +20 +20 +Connector_Harwin +Harwin_M20-7811245_2x12_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811245, 12 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +24 +24 +Connector_Harwin +Harwin_M20-7811545_2x15_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811545, 15 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +30 +30 +Connector_Harwin +Harwin_M20-7812045_2x20_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7812045, 20 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +40 +40 +Connector_Hirose +Hirose_BM24_BM24-40DP-2-0.35V_2x20_P0.35mm_PowerPin2_Vertical +Hirose BM24 series connector, BM24-40DP/2-0.35V (https://www.hirose.com/product/en/download_file/key_name/BM24/category/Catalog/doc_file_id/47680/?file_category_id=4&item_id=50&is_series=1) +connector Hirose BM24 40pin header +0 +44 +42 +Connector_Hirose +Hirose_BM24_BM24-40DS-2-0.35V_2x20_P0.35mm_PowerPin2_Vertical +Hirose BM24 series connector, BM24-40DS/2-0.35V (https://www.hirose.com/product/en/download_file/key_name/BM24/category/Catalog/doc_file_id/47680/?file_category_id=4&item_id=50&is_series=1) +connector Hirose 40pin receptacle vertical +0 +42 +42 +Connector_Hirose +Hirose_DF3EA-02P-2H_1x02-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-02P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +4 +3 +Connector_Hirose +Hirose_DF3EA-03P-2H_1x03-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-03P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +5 +4 +Connector_Hirose +Hirose_DF3EA-04P-2H_1x04-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-04P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +6 +5 +Connector_Hirose +Hirose_DF3EA-05P-2H_1x05-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-05P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +7 +6 +Connector_Hirose +Hirose_DF3EA-06P-2H_1x06-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-06P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +8 +7 +Connector_Hirose +Hirose_DF3EA-07P-2H_1x07-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-07P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +9 +8 +Connector_Hirose +Hirose_DF3EA-08P-2H_1x08-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-08P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +10 +9 +Connector_Hirose +Hirose_DF3EA-09P-2H_1x09-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-09P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +11 +10 +Connector_Hirose +Hirose_DF3EA-10P-2H_1x10-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-10P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +12 +11 +Connector_Hirose +Hirose_DF3EA-11P-2H_1x11-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-11P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +13 +12 +Connector_Hirose +Hirose_DF3EA-12P-2H_1x12-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-12P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +14 +13 +Connector_Hirose +Hirose_DF3EA-13P-2H_1x13-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-13P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +15 +14 +Connector_Hirose +Hirose_DF3EA-14P-2H_1x14-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-14P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +16 +15 +Connector_Hirose +Hirose_DF3EA-15P-2H_1x15-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-15P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +17 +16 +Connector_Hirose +Hirose_DF11-4DP-2DSA_2x02_P2.00mm_Vertical +Hirose DF11 through hole, DF11-4DP-2DSA, 2 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF11-6DP-2DSA_2x03_P2.00mm_Vertical +Hirose DF11 through hole, DF11-6DP-2DSA, 3 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF11-8DP-2DSA_2x04_P2.00mm_Vertical +Hirose DF11 through hole, DF11-8DP-2DSA, 4 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +8 +8 +Connector_Hirose +Hirose_DF11-10DP-2DSA_2x05_P2.00mm_Vertical +Hirose DF11 through hole, DF11-10DP-2DSA, 5 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +10 +10 +Connector_Hirose +Hirose_DF11-12DP-2DSA_2x06_P2.00mm_Vertical +Hirose DF11 through hole, DF11-12DP-2DSA, 6 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +12 +12 +Connector_Hirose +Hirose_DF11-14DP-2DSA_2x07_P2.00mm_Vertical +Hirose DF11 through hole, DF11-14DP-2DSA, 7 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +14 +14 +Connector_Hirose +Hirose_DF11-16DP-2DSA_2x08_P2.00mm_Vertical +Hirose DF11 through hole, DF11-16DP-2DSA, 8 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +16 +16 +Connector_Hirose +Hirose_DF11-18DP-2DSA_2x09_P2.00mm_Vertical +Hirose DF11 through hole, DF11-18DP-2DSA, 9 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +18 +18 +Connector_Hirose +Hirose_DF11-20DP-2DSA_2x10_P2.00mm_Vertical +Hirose DF11 through hole, DF11-20DP-2DSA, 10 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +20 +20 +Connector_Hirose +Hirose_DF11-22DP-2DSA_2x11_P2.00mm_Vertical +Hirose DF11 through hole, DF11-22DP-2DSA, 11 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +22 +22 +Connector_Hirose +Hirose_DF11-24DP-2DSA_2x12_P2.00mm_Vertical +Hirose DF11 through hole, DF11-24DP-2DSA, 12 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +24 +24 +Connector_Hirose +Hirose_DF11-26DP-2DSA_2x13_P2.00mm_Vertical +Hirose DF11 through hole, DF11-26DP-2DSA, 13 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +26 +26 +Connector_Hirose +Hirose_DF11-28DP-2DSA_2x14_P2.00mm_Vertical +Hirose DF11 through hole, DF11-28DP-2DSA, 14 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +28 +28 +Connector_Hirose +Hirose_DF11-30DP-2DSA_2x15_P2.00mm_Vertical +Hirose DF11 through hole, DF11-30DP-2DSA, 15 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +30 +30 +Connector_Hirose +Hirose_DF11-32DP-2DSA_2x16_P2.00mm_Vertical +Hirose DF11 through hole, DF11-32DP-2DSA, 16 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +32 +32 +Connector_Hirose +Hirose_DF12_DF12C3.0-10DS-0.5V_2x05_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-10DS-0.5V, 10 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +20 +10 +Connector_Hirose +Hirose_DF12_DF12C3.0-14DS-0.5V_2x07_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-14DS-0.5V, 14 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +28 +14 +Connector_Hirose +Hirose_DF12_DF12C3.0-20DS-0.5V_2x10_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-20DS-0.5V, 20 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +40 +20 +Connector_Hirose +Hirose_DF12_DF12C3.0-30DS-0.5V_2x15_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-30DS-0.5V, 30 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +60 +30 +Connector_Hirose +Hirose_DF12_DF12C3.0-32DS-0.5V_2x16_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-32DS-0.5V, 32 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +64 +32 +Connector_Hirose +Hirose_DF12_DF12C3.0-36DS-0.5V_2x18_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-36DS-0.5V, 36 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +72 +36 +Connector_Hirose +Hirose_DF12_DF12C3.0-40DS-0.5V_2x20_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-40DS-0.5V, 40 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +80 +40 +Connector_Hirose +Hirose_DF12_DF12C3.0-50DS-0.5V_2x25_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-50DS-0.5V, 50 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +100 +50 +Connector_Hirose +Hirose_DF12_DF12C3.0-60DS-0.5V_2x30_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-60DS-0.5V, 60 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +120 +60 +Connector_Hirose +Hirose_DF12_DF12E3.0-10DP-0.5V_2x05_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-10DP-0.5V, 10 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +20 +10 +Connector_Hirose +Hirose_DF12_DF12E3.0-14DP-0.5V_2x07_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-14DP-0.5V, 14 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +28 +14 +Connector_Hirose +Hirose_DF12_DF12E3.0-20DP-0.5V_2x10_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-20DP-0.5V, 20 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +40 +20 +Connector_Hirose +Hirose_DF12_DF12E3.0-30DP-0.5V_2x15_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-30DP-0.5V, 30 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +60 +30 +Connector_Hirose +Hirose_DF12_DF12E3.0-32DP-0.5V_2x16_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-32DP-0.5V, 32 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +64 +32 +Connector_Hirose +Hirose_DF12_DF12E3.0-36DP-0.5V_2x18_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-36DP-0.5V, 36 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +72 +36 +Connector_Hirose +Hirose_DF12_DF12E3.0-40DP-0.5V_2x20_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-40DP-0.5V, 40 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +80 +40 +Connector_Hirose +Hirose_DF12_DF12E3.0-50DP-0.5V_2x25_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-50DP-0.5V, 50 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +100 +50 +Connector_Hirose +Hirose_DF12_DF12E3.0-60DP-0.5V_2x30_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-60DP-0.5V, 60 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +120 +60 +Connector_Hirose +Hirose_DF12_DF12E3.0-80DP-0.5V_2x40_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-80DP-0.5V, 80 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +160 +80 +Connector_Hirose +Hirose_DF13-02P-1.25DSA_1x02_P1.25mm_Vertical +Hirose DF13 through hole, DF13-02P-1.25DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF13-02P-1.25DS_1x02_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-02P-1.25DS, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +2 +2 +Connector_Hirose +Hirose_DF13-03P-1.25DSA_1x03_P1.25mm_Vertical +Hirose DF13 through hole, DF13-03P-1.25DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF13-03P-1.25DS_1x03_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-03P-1.25DS, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +3 +3 +Connector_Hirose +Hirose_DF13-04P-1.25DSA_1x04_P1.25mm_Vertical +Hirose DF13 through hole, DF13-04P-1.25DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF13-04P-1.25DS_1x04_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-04P-1.25DS, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +4 +4 +Connector_Hirose +Hirose_DF13-05P-1.25DSA_1x05_P1.25mm_Vertical +Hirose DF13 through hole, DF13-05P-1.25DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +5 +5 +Connector_Hirose +Hirose_DF13-05P-1.25DS_1x05_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-05P-1.25DS, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +5 +5 +Connector_Hirose +Hirose_DF13-06P-1.25DSA_1x06_P1.25mm_Vertical +Hirose DF13 through hole, DF13-06P-1.25DSA, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF13-06P-1.25DS_1x06_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-06P-1.25DS, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +6 +6 +Connector_Hirose +Hirose_DF13-07P-1.25DSA_1x07_P1.25mm_Vertical +Hirose DF13 through hole, DF13-07P-1.25DSA, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +7 +7 +Connector_Hirose +Hirose_DF13-07P-1.25DS_1x07_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-07P-1.25DS, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +7 +7 +Connector_Hirose +Hirose_DF13-08P-1.25DSA_1x08_P1.25mm_Vertical +Hirose DF13 through hole, DF13-08P-1.25DSA, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +8 +8 +Connector_Hirose +Hirose_DF13-08P-1.25DS_1x08_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-08P-1.25DS, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +8 +8 +Connector_Hirose +Hirose_DF13-09P-1.25DSA_1x09_P1.25mm_Vertical +Hirose DF13 through hole, DF13-09P-1.25DSA, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +9 +9 +Connector_Hirose +Hirose_DF13-09P-1.25DS_1x09_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-09P-1.25DS, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +9 +9 +Connector_Hirose +Hirose_DF13-10P-1.25DSA_1x10_P1.25mm_Vertical +Hirose DF13 through hole, DF13-10P-1.25DSA, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +10 +10 +Connector_Hirose +Hirose_DF13-10P-1.25DS_1x10_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-10P-1.25DS, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +10 +10 +Connector_Hirose +Hirose_DF13-11P-1.25DSA_1x11_P1.25mm_Vertical +Hirose DF13 through hole, DF13-11P-1.25DSA, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +11 +11 +Connector_Hirose +Hirose_DF13-11P-1.25DS_1x11_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-11P-1.25DS, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +11 +11 +Connector_Hirose +Hirose_DF13-12P-1.25DSA_1x12_P1.25mm_Vertical +Hirose DF13 through hole, DF13-12P-1.25DSA, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +12 +12 +Connector_Hirose +Hirose_DF13-12P-1.25DS_1x12_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-12P-1.25DS, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +12 +12 +Connector_Hirose +Hirose_DF13-13P-1.25DSA_1x13_P1.25mm_Vertical +Hirose DF13 through hole, DF13-13P-1.25DSA, 13 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +13 +13 +Connector_Hirose +Hirose_DF13-14P-1.25DSA_1x14_P1.25mm_Vertical +Hirose DF13 through hole, DF13-14P-1.25DSA, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +14 +14 +Connector_Hirose +Hirose_DF13-14P-1.25DS_1x14_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-14P-1.25DS, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +14 +14 +Connector_Hirose +Hirose_DF13-15P-1.25DSA_1x15_P1.25mm_Vertical +Hirose DF13 through hole, DF13-15P-1.25DSA, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +15 +15 +Connector_Hirose +Hirose_DF13-15P-1.25DS_1x15_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-15P-1.25DS, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +15 +15 +Connector_Hirose +Hirose_DF13C_CL535-0402-2-51_1x02-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0402-2-51, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +4 +3 +Connector_Hirose +Hirose_DF13C_CL535-0403-5-51_1x03-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0403-5-51, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +5 +4 +Connector_Hirose +Hirose_DF13C_CL535-0404-8-51_1x04-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0404-8-51, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +6 +5 +Connector_Hirose +Hirose_DF13C_CL535-0405-0-51_1x05-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0405-0-51, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +7 +6 +Connector_Hirose +Hirose_DF13C_CL535-0406-3-51_1x06-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0406-3-51, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +8 +7 +Connector_Hirose +Hirose_DF13C_CL535-0407-6-51_1x07-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0407-6-51, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +9 +8 +Connector_Hirose +Hirose_DF13C_CL535-0408-9-51_1x08-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0408-9-51, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +10 +9 +Connector_Hirose +Hirose_DF13C_CL535-0409-1-51_1x09-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0409-1-51, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +11 +10 +Connector_Hirose +Hirose_DF13C_CL535-0410-4-51_1x10-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0410-4-51, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +12 +11 +Connector_Hirose +Hirose_DF13C_CL535-0411-3-51_1x11-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0411-3-51, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +13 +12 +Connector_Hirose +Hirose_DF13C_CL535-0412-6-51_1x12-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0412-6-51, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +14 +13 +Connector_Hirose +Hirose_DF13C_CL535-0414-1-51_1x14-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0414-1-51, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +16 +15 +Connector_Hirose +Hirose_DF13C_CL535-0415-4-51_1x15-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0415-4-51, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +17 +16 +Connector_Hirose +Hirose_DF52-2S-0.8H_1x02-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-2S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +4 +3 +Connector_Hirose +Hirose_DF52-3S-0.8H_1x03-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-3S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +5 +4 +Connector_Hirose +Hirose_DF52-4S-0.8H_1x04-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-4S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +6 +5 +Connector_Hirose +Hirose_DF52-5S-0.8H_1x05-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-5S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +7 +6 +Connector_Hirose +Hirose_DF52-6S-0.8H_1x06-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-6S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +8 +7 +Connector_Hirose +Hirose_DF52-7S-0.8H_1x07-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-7S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +9 +8 +Connector_Hirose +Hirose_DF52-8S-0.8H_1x08-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-8S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +10 +9 +Connector_Hirose +Hirose_DF52-9S-0.8H_1x09-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-9S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +11 +10 +Connector_Hirose +Hirose_DF52-10S-0.8H_1x10-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-10S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +12 +11 +Connector_Hirose +Hirose_DF52-11S-0.8H_1x11-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-11S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +13 +12 +Connector_Hirose +Hirose_DF52-12S-0.8H_1x12-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-12S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +14 +13 +Connector_Hirose +Hirose_DF52-14S-0.8H_1x14-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-14S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +16 +15 +Connector_Hirose +Hirose_DF52-15S-0.8H_1x15-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-15S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +17 +16 +Connector_Hirose +Hirose_DF63-5P-3.96DSA_1x05_P3.96mm_Vertical +Hirose DF63 through hole, DF63-5P-3.96DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +5 +5 +Connector_Hirose +Hirose_DF63-6P-3.96DSA_1x06_P3.96mm_Vertical +Hirose DF63 through hole, DF63-6P-3.96DSA, 6 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF63M-1P-3.96DSA_1x01_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-1P-3.96DSA, 1 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +1 +1 +Connector_Hirose +Hirose_DF63M-2P-3.96DSA_1x02_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-2P-3.96DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF63M-3P-3.96DSA_1x03_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-3P-3.96DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF63M-4P-3.96DSA_1x04_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-4P-3.96DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF63R-1P-3.96DSA_1x01_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-1P-3.96DSA, 1 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +1 +1 +Connector_Hirose +Hirose_DF63R-2P-3.96DSA_1x02_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-2P-3.96DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF63R-3P-3.96DSA_1x03_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-3P-3.96DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF63R-4P-3.96DSA_1x04_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-4P-3.96DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF63R-5P-3.96DSA_1x05_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-5P-3.96DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +5 +5 +Connector_IDC +IDC-Header_2x03_P2.54mm_Horizontal +Through hole IDC box header, 2x03, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x03 2.54mm double row +0 +6 +6 +Connector_IDC +IDC-Header_2x03_P2.54mm_Vertical +Through hole IDC box header, 2x03, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x03 2.54mm double row +0 +6 +6 +Connector_IDC +IDC-Header_2x04_P2.54mm_Horizontal +Through hole IDC box header, 2x04, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x04 2.54mm double row +0 +8 +8 +Connector_IDC +IDC-Header_2x04_P2.54mm_Vertical +Through hole IDC box header, 2x04, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x04 2.54mm double row +0 +8 +8 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05_P2.54mm_Horizontal +Through hole IDC box header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Vertical +Through hole IDC box header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06_P2.54mm_Horizontal +Through hole IDC box header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Vertical +Through hole IDC box header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07_P2.54mm_Horizontal +Through hole IDC box header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Horizontal_Lock +Connector IDC Locked, 10 contacts, compatible header: PANCON HE10 (Series 50, (https://www.reboul.fr/storage/00003af6.pdf) +connector idc locked +0 +16 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Vertical +Through hole IDC box header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08_P2.54mm_Horizontal +Through hole IDC box header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Vertical +Through hole IDC box header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10_P2.54mm_Horizontal +Through hole IDC box header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Vertical +Through hole IDC box header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12_P2.54mm_Horizontal +Through hole IDC box header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Vertical +Through hole IDC box header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13_P2.54mm_Horizontal +Through hole IDC box header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Vertical +Through hole IDC box header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15_P2.54mm_Horizontal +Through hole IDC box header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Vertical +Through hole IDC box header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17_P2.54mm_Horizontal +Through hole IDC box header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Vertical +Through hole IDC box header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20_P2.54mm_Horizontal +Through hole IDC box header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Vertical +Through hole IDC box header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25_P2.54mm_Horizontal +Through hole IDC box header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Vertical +Through hole IDC box header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30_P2.54mm_Horizontal +Through hole IDC box header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Vertical +Through hole IDC box header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32_P2.54mm_Horizontal +Through hole IDC box header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Vertical +Through hole IDC box header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x32 2.54mm double row +0 +64 +64 +Connector_JAE +JAE_LY20-4P-DLT1_2x02_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-4P-DLT1, 2 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +4 +4 +Connector_JAE +JAE_LY20-4P-DT1_2x02_P2.00mm_Vertical +Molex LY 20 series connector, LY20-4P-DT1, 2 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +4 +4 +Connector_JAE +JAE_LY20-6P-DLT1_2x03_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-6P-DLT1, 3 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +6 +6 +Connector_JAE +JAE_LY20-6P-DT1_2x03_P2.00mm_Vertical +Molex LY 20 series connector, LY20-6P-DT1, 3 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +6 +6 +Connector_JAE +JAE_LY20-8P-DLT1_2x04_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-8P-DLT1, 4 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +8 +8 +Connector_JAE +JAE_LY20-8P-DT1_2x04_P2.00mm_Vertical +Molex LY 20 series connector, LY20-8P-DT1, 4 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +8 +8 +Connector_JAE +JAE_LY20-10P-DLT1_2x05_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-10P-DLT1, 5 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +10 +10 +Connector_JAE +JAE_LY20-10P-DT1_2x05_P2.00mm_Vertical +Molex LY 20 series connector, LY20-10P-DT1, 5 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +10 +10 +Connector_JAE +JAE_LY20-12P-DLT1_2x06_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-12P-DLT1, 6 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +12 +12 +Connector_JAE +JAE_LY20-12P-DT1_2x06_P2.00mm_Vertical +Molex LY 20 series connector, LY20-12P-DT1, 6 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +12 +12 +Connector_JAE +JAE_LY20-14P-DLT1_2x07_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-14P-DLT1, 7 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +14 +14 +Connector_JAE +JAE_LY20-14P-DT1_2x07_P2.00mm_Vertical +Molex LY 20 series connector, LY20-14P-DT1, 7 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +14 +14 +Connector_JAE +JAE_LY20-16P-DLT1_2x08_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-16P-DLT1, 8 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +16 +16 +Connector_JAE +JAE_LY20-16P-DT1_2x08_P2.00mm_Vertical +Molex LY 20 series connector, LY20-16P-DT1, 8 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +16 +16 +Connector_JAE +JAE_LY20-18P-DLT1_2x09_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-18P-DLT1, 9 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +18 +18 +Connector_JAE +JAE_LY20-18P-DT1_2x09_P2.00mm_Vertical +Molex LY 20 series connector, LY20-18P-DT1, 9 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +18 +18 +Connector_JAE +JAE_LY20-20P-DLT1_2x10_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-20P-DLT1, 10 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +20 +20 +Connector_JAE +JAE_LY20-20P-DT1_2x10_P2.00mm_Vertical +Molex LY 20 series connector, LY20-20P-DT1, 10 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +20 +20 +Connector_JAE +JAE_LY20-22P-DLT1_2x11_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-22P-DLT1, 11 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +22 +22 +Connector_JAE +JAE_LY20-22P-DT1_2x11_P2.00mm_Vertical +Molex LY 20 series connector, LY20-22P-DT1, 11 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +22 +22 +Connector_JAE +JAE_LY20-24P-DLT1_2x12_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-24P-DLT1, 12 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +24 +24 +Connector_JAE +JAE_LY20-24P-DT1_2x12_P2.00mm_Vertical +Molex LY 20 series connector, LY20-24P-DT1, 12 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +24 +24 +Connector_JAE +JAE_LY20-26P-DLT1_2x13_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-26P-DLT1, 13 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +26 +26 +Connector_JAE +JAE_LY20-26P-DT1_2x13_P2.00mm_Vertical +Molex LY 20 series connector, LY20-26P-DT1, 13 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +26 +26 +Connector_JAE +JAE_LY20-28P-DLT1_2x14_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-28P-DLT1, 14 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +28 +28 +Connector_JAE +JAE_LY20-28P-DT1_2x14_P2.00mm_Vertical +Molex LY 20 series connector, LY20-28P-DT1, 14 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +28 +28 +Connector_JAE +JAE_LY20-30P-DLT1_2x15_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-30P-DLT1, 15 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +30 +30 +Connector_JAE +JAE_LY20-30P-DT1_2x15_P2.00mm_Vertical +Molex LY 20 series connector, LY20-30P-DT1, 15 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +30 +30 +Connector_JAE +JAE_LY20-32P-DLT1_2x16_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-32P-DLT1, 16 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +32 +32 +Connector_JAE +JAE_LY20-32P-DT1_2x16_P2.00mm_Vertical +Molex LY 20 series connector, LY20-32P-DT1, 16 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +32 +32 +Connector_JAE +JAE_LY20-34P-DLT1_2x17_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-34P-DLT1, 17 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +34 +34 +Connector_JAE +JAE_LY20-34P-DT1_2x17_P2.00mm_Vertical +Molex LY 20 series connector, LY20-34P-DT1, 17 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +34 +34 +Connector_JAE +JAE_LY20-36P-DLT1_2x18_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-36P-DLT1, 18 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +36 +36 +Connector_JAE +JAE_LY20-36P-DT1_2x18_P2.00mm_Vertical +Molex LY 20 series connector, LY20-36P-DT1, 18 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +36 +36 +Connector_JAE +JAE_LY20-38P-DLT1_2x19_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-38P-DLT1, 19 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +38 +38 +Connector_JAE +JAE_LY20-38P-DT1_2x19_P2.00mm_Vertical +Molex LY 20 series connector, LY20-38P-DT1, 19 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +38 +38 +Connector_JAE +JAE_LY20-40P-DLT1_2x20_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-40P-DLT1, 20 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +40 +40 +Connector_JAE +JAE_LY20-40P-DT1_2x20_P2.00mm_Vertical +Molex LY 20 series connector, LY20-40P-DT1, 20 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +40 +40 +Connector_JAE +JAE_LY20-42P-DLT1_2x21_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-42P-DLT1, 21 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +42 +42 +Connector_JAE +JAE_LY20-42P-DT1_2x21_P2.00mm_Vertical +Molex LY 20 series connector, LY20-42P-DT1, 21 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +42 +42 +Connector_JAE +JAE_LY20-44P-DLT1_2x22_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-44P-DLT1, 22 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +44 +44 +Connector_JAE +JAE_LY20-44P-DT1_2x22_P2.00mm_Vertical +Molex LY 20 series connector, LY20-44P-DT1, 22 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +44 +44 +Connector_JAE +JAE_MM70-314-310B1 +http://www.heilind.com/marketing/documents/jae/JAE_MM70.pdf +connector JAE MXM +0 +280 +279 +Connector_JAE +JAE_SIM_Card_SF72S006 +SIM Card, Push-Push, https://www.jae.com/direct/topics/topics_file_download/topics_id=68892&ext_no=06&index=0&_lang=en&v=202003111511468456809 +SIM Card with Detect Switch +0 +18 +9 +Connector_JST +JST_ACH_BM01B-ACHSS-A-GAN-ETF_1x01-1MP_P1.20mm_Vertical +JST ACH series connector, BM01B-ACHSS-A-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +3 +2 +Connector_JST +JST_ACH_BM02B-ACHSS-GAN-ETF_1x02-1MP_P1.20mm_Vertical +JST ACH series connector, BM02B-ACHSS-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +4 +3 +Connector_JST +JST_ACH_BM03B-ACHSS-GAN-ETF_1x03-1MP_P1.20mm_Vertical +JST ACH series connector, BM03B-ACHSS-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +5 +4 +Connector_JST +JST_ACH_BM04B-ACHSS-A-GAN-ETF_1x04-1MP_P1.20mm_Vertical +JST ACH series connector, BM04B-ACHSS-A-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +6 +5 +Connector_JST +JST_ACH_BM05B-ACHSS-A-GAN-ETF_1x05-1MP_P1.20mm_Vertical +JST ACH series connector, BM05B-ACHSS-A-GAN-ETF (http://www.jst-mfg.com/product/pdf/eng/eACH.pdf), generated with kicad-footprint-generator +connector JST ACH vertical +0 +7 +6 +Connector_JST +JST_AUH_BM03B-AUHKS-GA-TB_1x03-1MP_P1.50mm_Vertical +JST AUH series connector, BM03B-AUHKS-GA-TB (http://www.jst-mfg.com/product/pdf/eng/eAUH.pdf), generated with kicad-footprint-generator +connector JST AUH side entry +0 +5 +4 +Connector_JST +JST_AUH_BM05B-AUHKS-GA-TB_1x05-1MP_P1.50mm_Vertical +JST AUH series connector, BM05B-AUHKS-GA-TB (http://www.jst-mfg.com/product/pdf/eng/eAUH.pdf), generated with kicad-footprint-generator +connector JST AUH side entry +0 +7 +6 +Connector_JST +JST_EH_B2B-EH-A_1x02_P2.50mm_Vertical +JST EH series connector, B2B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +2 +2 +Connector_JST +JST_EH_B3B-EH-A_1x03_P2.50mm_Vertical +JST EH series connector, B3B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +3 +3 +Connector_JST +JST_EH_B4B-EH-A_1x04_P2.50mm_Vertical +JST EH series connector, B4B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +4 +4 +Connector_JST +JST_EH_B5B-EH-A_1x05_P2.50mm_Vertical +JST EH series connector, B5B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +5 +5 +Connector_JST +JST_EH_B6B-EH-A_1x06_P2.50mm_Vertical +JST EH series connector, B6B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +6 +6 +Connector_JST +JST_EH_B7B-EH-A_1x07_P2.50mm_Vertical +JST EH series connector, B7B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +7 +7 +Connector_JST +JST_EH_B8B-EH-A_1x08_P2.50mm_Vertical +JST EH series connector, B8B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +8 +8 +Connector_JST +JST_EH_B9B-EH-A_1x09_P2.50mm_Vertical +JST EH series connector, B9B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH vertical +0 +9 +9 +Connector_JST +JST_EH_B10B-EH-A_1x10_P2.50mm_Vertical +JST EH series connector, B10B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +10 +10 +Connector_JST +JST_EH_B11B-EH-A_1x11_P2.50mm_Vertical +JST EH series connector, B11B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +11 +11 +Connector_JST +JST_EH_B12B-EH-A_1x12_P2.50mm_Vertical +JST EH series connector, B12B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +12 +12 +Connector_JST +JST_EH_B13B-EH-A_1x13_P2.50mm_Vertical +JST EH series connector, B13B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +13 +13 +Connector_JST +JST_EH_B14B-EH-A_1x14_P2.50mm_Vertical +JST EH series connector, B14B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +14 +14 +Connector_JST +JST_EH_B15B-EH-A_1x15_P2.50mm_Vertical +JST EH series connector, B15B-EH-A (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH side entry +0 +15 +15 +Connector_JST +JST_EH_S2B-EH_1x02_P2.50mm_Horizontal +JST EH series connector, S2B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +2 +2 +Connector_JST +JST_EH_S3B-EH_1x03_P2.50mm_Horizontal +JST EH series connector, S3B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +3 +3 +Connector_JST +JST_EH_S4B-EH_1x04_P2.50mm_Horizontal +JST EH series connector, S4B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +4 +4 +Connector_JST +JST_EH_S5B-EH_1x05_P2.50mm_Horizontal +JST EH series connector, S5B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +5 +5 +Connector_JST +JST_EH_S6B-EH_1x06_P2.50mm_Horizontal +JST EH series connector, S6B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +6 +6 +Connector_JST +JST_EH_S7B-EH_1x07_P2.50mm_Horizontal +JST EH series connector, S7B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +7 +7 +Connector_JST +JST_EH_S8B-EH_1x08_P2.50mm_Horizontal +JST EH series connector, S8B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +8 +8 +Connector_JST +JST_EH_S9B-EH_1x09_P2.50mm_Horizontal +JST EH series connector, S9B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH horizontal +0 +9 +9 +Connector_JST +JST_EH_S10B-EH_1x10_P2.50mm_Horizontal +JST EH series connector, S10B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +10 +10 +Connector_JST +JST_EH_S11B-EH_1x11_P2.50mm_Horizontal +JST EH series connector, S11B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +11 +11 +Connector_JST +JST_EH_S12B-EH_1x12_P2.50mm_Horizontal +JST EH series connector, S12B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +12 +12 +Connector_JST +JST_EH_S13B-EH_1x13_P2.50mm_Horizontal +JST EH series connector, S13B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +13 +13 +Connector_JST +JST_EH_S14B-EH_1x14_P2.50mm_Horizontal +JST EH series connector, S14B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +14 +14 +Connector_JST +JST_EH_S15B-EH_1x15_P2.50mm_Horizontal +JST EH series connector, S15B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator +connector JST EH top entry +0 +15 +15 +Connector_JST +JST_GH_BM02B-GHS-TBT_1x02-1MP_P1.25mm_Vertical +JST GH series connector, BM02B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +4 +3 +Connector_JST +JST_GH_BM03B-GHS-TBT_1x03-1MP_P1.25mm_Vertical +JST GH series connector, BM03B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +5 +4 +Connector_JST +JST_GH_BM04B-GHS-TBT_1x04-1MP_P1.25mm_Vertical +JST GH series connector, BM04B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +6 +5 +Connector_JST +JST_GH_BM05B-GHS-TBT_1x05-1MP_P1.25mm_Vertical +JST GH series connector, BM05B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +7 +6 +Connector_JST +JST_GH_BM06B-GHS-TBT_1x06-1MP_P1.25mm_Vertical +JST GH series connector, BM06B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +8 +7 +Connector_JST +JST_GH_BM07B-GHS-TBT_1x07-1MP_P1.25mm_Vertical +JST GH series connector, BM07B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +9 +8 +Connector_JST +JST_GH_BM08B-GHS-TBT_1x08-1MP_P1.25mm_Vertical +JST GH series connector, BM08B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +10 +9 +Connector_JST +JST_GH_BM09B-GHS-TBT_1x09-1MP_P1.25mm_Vertical +JST GH series connector, BM09B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +11 +10 +Connector_JST +JST_GH_BM10B-GHS-TBT_1x10-1MP_P1.25mm_Vertical +JST GH series connector, BM10B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +12 +11 +Connector_JST +JST_GH_BM11B-GHS-TBT_1x11-1MP_P1.25mm_Vertical +JST GH series connector, BM11B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +13 +12 +Connector_JST +JST_GH_BM12B-GHS-TBT_1x12-1MP_P1.25mm_Vertical +JST GH series connector, BM12B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +14 +13 +Connector_JST +JST_GH_BM13B-GHS-TBT_1x13-1MP_P1.25mm_Vertical +JST GH series connector, BM13B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +15 +14 +Connector_JST +JST_GH_BM14B-GHS-TBT_1x14-1MP_P1.25mm_Vertical +JST GH series connector, BM14B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +16 +15 +Connector_JST +JST_GH_BM15B-GHS-TBT_1x15-1MP_P1.25mm_Vertical +JST GH series connector, BM15B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH side entry +0 +17 +16 +Connector_JST +JST_GH_SM02B-GHS-TB_1x02-1MP_P1.25mm_Horizontal +JST GH series connector, SM02B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +4 +3 +Connector_JST +JST_GH_SM03B-GHS-TB_1x03-1MP_P1.25mm_Horizontal +JST GH series connector, SM03B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +5 +4 +Connector_JST +JST_GH_SM04B-GHS-TB_1x04-1MP_P1.25mm_Horizontal +JST GH series connector, SM04B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +6 +5 +Connector_JST +JST_GH_SM05B-GHS-TB_1x05-1MP_P1.25mm_Horizontal +JST GH series connector, SM05B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +7 +6 +Connector_JST +JST_GH_SM06B-GHS-TB_1x06-1MP_P1.25mm_Horizontal +JST GH series connector, SM06B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +8 +7 +Connector_JST +JST_GH_SM07B-GHS-TB_1x07-1MP_P1.25mm_Horizontal +JST GH series connector, SM07B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +9 +8 +Connector_JST +JST_GH_SM08B-GHS-TB_1x08-1MP_P1.25mm_Horizontal +JST GH series connector, SM08B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +10 +9 +Connector_JST +JST_GH_SM09B-GHS-TB_1x09-1MP_P1.25mm_Horizontal +JST GH series connector, SM09B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +11 +10 +Connector_JST +JST_GH_SM10B-GHS-TB_1x10-1MP_P1.25mm_Horizontal +JST GH series connector, SM10B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +12 +11 +Connector_JST +JST_GH_SM11B-GHS-TB_1x11-1MP_P1.25mm_Horizontal +JST GH series connector, SM11B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +13 +12 +Connector_JST +JST_GH_SM12B-GHS-TB_1x12-1MP_P1.25mm_Horizontal +JST GH series connector, SM12B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +14 +13 +Connector_JST +JST_GH_SM13B-GHS-TB_1x13-1MP_P1.25mm_Horizontal +JST GH series connector, SM13B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +15 +14 +Connector_JST +JST_GH_SM14B-GHS-TB_1x14-1MP_P1.25mm_Horizontal +JST GH series connector, SM14B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +16 +15 +Connector_JST +JST_GH_SM15B-GHS-TB_1x15-1MP_P1.25mm_Horizontal +JST GH series connector, SM15B-GHS-TB (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator +connector JST GH top entry +0 +17 +16 +Connector_JST +JST_J2100_B06B-J21DK-GGXR_2x03_P2.50x4.00mm_Vertical +JST J2100 series connector, B06B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +8 +6 +Connector_JST +JST_J2100_B08B-J21DK-GGXR_2x04_P2.50x4.00mm_Vertical +JST J2100 series connector, B08B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +10 +8 +Connector_JST +JST_J2100_B10B-J21DK-GGXR_2x05_P2.50x4.00mm_Vertical +JST J2100 series connector, B10B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +12 +10 +Connector_JST +JST_J2100_B12B-J21DK-GGXR_2x06_P2.50x4.00mm_Vertical +JST J2100 series connector, B12B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +14 +12 +Connector_JST +JST_J2100_B16B-J21DK-GGXR_2x08_P2.50x4.00mm_Vertical +JST J2100 series connector, B16B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +18 +16 +Connector_JST +JST_J2100_B20B-J21DK-GGXR_2x10_P2.50x4.00mm_Vertical +JST J2100 series connector, B20B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 vertical +0 +22 +20 +Connector_JST +JST_J2100_S06B-J21DK-GGXR_2x03_P2.50mm_Horizontal +JST J2100 series connector, S06B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +7 +6 +Connector_JST +JST_J2100_S08B-J21DK-GGXR_2x04_P2.50mm_Horizontal +JST J2100 series connector, S08B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +10 +8 +Connector_JST +JST_J2100_S10B-J21DK-GGXR_2x05_P2.50mm_Horizontal +JST J2100 series connector, S10B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +12 +10 +Connector_JST +JST_J2100_S12B-J21DK-GGXR_2x06_P2.50mm_Horizontal +JST J2100 series connector, S12B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +14 +12 +Connector_JST +JST_J2100_S16B-J21DK-GGXR_2x08_P2.50mm_Horizontal +JST J2100 series connector, S16B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +18 +16 +Connector_JST +JST_J2100_S20B-J21DK-GGXR_2x10_P2.50mm_Horizontal +JST J2100 series connector, S20B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with kicad-footprint-generator +connector JST J2100 horizontal +0 +22 +20 +Connector_JST +JST_JWPF_B02B-JWPF-SK-R_1x02_P2.00mm_Vertical +JST JWPF series connector, B02B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +2 +2 +Connector_JST +JST_JWPF_B03B-JWPF-SK-R_1x03_P2.00mm_Vertical +JST JWPF series connector, B03B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +3 +3 +Connector_JST +JST_JWPF_B04B-JWPF-SK-R_1x04_P2.00mm_Vertical +JST JWPF series connector, B04B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +4 +4 +Connector_JST +JST_JWPF_B06B-JWPF-SK-R_2x03_P2.00mm_Vertical +JST JWPF series connector, B06B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +6 +6 +Connector_JST +JST_JWPF_B08B-JWPF-SK-R_2x04_P2.00mm_Vertical +JST JWPF series connector, B08B-JWPF-SK-R (http://www.jst-mfg.com/product/pdf/eng/eJWPF1.pdf), generated with kicad-footprint-generator +connector JST JWPF side entry +0 +8 +8 +Connector_JST +JST_LEA_SM02B-LEASS-TF_1x02-1MP_P4.20mm_Horizontal +JST LEA series connector, SM02B-LEASS-TF (http://www.jst-mfg.com/product/pdf/eng/eLEA.pdf), generated with kicad-footprint-generator +connector JST LEA top entry +0 +4 +3 +Connector_JST +JST_NV_B02P-NV_1x02_P5.00mm_Vertical +JST NV series connector, B02P-NV (http://www.jst-mfg.com/product/pdf/eng/eNV.pdf), generated with kicad-footprint-generator +connector JST NV side entry +0 +2 +2 +Connector_JST +JST_NV_B03P-NV_1x03_P5.00mm_Vertical +JST NV series connector, B03P-NV (http://www.jst-mfg.com/product/pdf/eng/eNV.pdf), generated with kicad-footprint-generator +connector JST NV side entry +0 +3 +3 +Connector_JST +JST_NV_B04P-NV_1x04_P5.00mm_Vertical +JST NV series connector, B04P-NV (http://www.jst-mfg.com/product/pdf/eng/eNV.pdf), generated with kicad-footprint-generator +connector JST NV side entry +0 +4 +4 +Connector_JST +JST_PHD_B8B-PHDSS_2x04_P2.00mm_Vertical +JST PHD series connector, B8B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +8 +8 +Connector_JST +JST_PHD_B10B-PHDSS_2x05_P2.00mm_Vertical +JST PHD series connector, B10B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +10 +10 +Connector_JST +JST_PHD_B12B-PHDSS_2x06_P2.00mm_Vertical +JST PHD series connector, B12B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +12 +12 +Connector_JST +JST_PHD_B14B-PHDSS_2x07_P2.00mm_Vertical +JST PHD series connector, B14B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +14 +14 +Connector_JST +JST_PHD_B16B-PHDSS_2x08_P2.00mm_Vertical +JST PHD series connector, B16B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +16 +16 +Connector_JST +JST_PHD_B18B-PHDSS_2x09_P2.00mm_Vertical +JST PHD series connector, B18B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +18 +18 +Connector_JST +JST_PHD_B20B-PHDSS_2x10_P2.00mm_Vertical +JST PHD series connector, B20B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +20 +20 +Connector_JST +JST_PHD_B22B-PHDSS_2x11_P2.00mm_Vertical +JST PHD series connector, B22B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +22 +22 +Connector_JST +JST_PHD_B24B-PHDSS_2x12_P2.00mm_Vertical +JST PHD series connector, B24B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +24 +24 +Connector_JST +JST_PHD_B26B-PHDSS_2x13_P2.00mm_Vertical +JST PHD series connector, B26B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +26 +26 +Connector_JST +JST_PHD_B28B-PHDSS_2x14_P2.00mm_Vertical +JST PHD series connector, B28B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +28 +28 +Connector_JST +JST_PHD_B30B-PHDSS_2x15_P2.00mm_Vertical +JST PHD series connector, B30B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +30 +30 +Connector_JST +JST_PHD_B32B-PHDSS_2x16_P2.00mm_Vertical +JST PHD series connector, B32B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +32 +32 +Connector_JST +JST_PHD_B34B-PHDSS_2x17_P2.00mm_Vertical +JST PHD series connector, B34B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD vertical +0 +34 +34 +Connector_JST +JST_PHD_S8B-PHDSS_2x04_P2.00mm_Horizontal +JST PHD series connector, S8B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +8 +8 +Connector_JST +JST_PHD_S10B-PHDSS_2x05_P2.00mm_Horizontal +JST PHD series connector, S10B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +10 +10 +Connector_JST +JST_PHD_S12B-PHDSS_2x06_P2.00mm_Horizontal +JST PHD series connector, S12B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +12 +12 +Connector_JST +JST_PHD_S14B-PHDSS_2x07_P2.00mm_Horizontal +JST PHD series connector, S14B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +14 +14 +Connector_JST +JST_PHD_S16B-PHDSS_2x08_P2.00mm_Horizontal +JST PHD series connector, S16B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +16 +16 +Connector_JST +JST_PHD_S18B-PHDSS_2x09_P2.00mm_Horizontal +JST PHD series connector, S18B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +18 +18 +Connector_JST +JST_PHD_S20B-PHDSS_2x10_P2.00mm_Horizontal +JST PHD series connector, S20B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +20 +20 +Connector_JST +JST_PHD_S22B-PHDSS_2x11_P2.00mm_Horizontal +JST PHD series connector, S22B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +22 +22 +Connector_JST +JST_PHD_S24B-PHDSS_2x12_P2.00mm_Horizontal +JST PHD series connector, S24B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +24 +24 +Connector_JST +JST_PHD_S26B-PHDSS_2x13_P2.00mm_Horizontal +JST PHD series connector, S26B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +26 +26 +Connector_JST +JST_PHD_S28B-PHDSS_2x14_P2.00mm_Horizontal +JST PHD series connector, S28B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +28 +28 +Connector_JST +JST_PHD_S30B-PHDSS_2x15_P2.00mm_Horizontal +JST PHD series connector, S30B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +30 +30 +Connector_JST +JST_PHD_S32B-PHDSS_2x16_P2.00mm_Horizontal +JST PHD series connector, S32B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +32 +32 +Connector_JST +JST_PHD_S34B-PHDSS_2x17_P2.00mm_Horizontal +JST PHD series connector, S34B-PHDSS (http://www.jst-mfg.com/product/pdf/eng/ePHD.pdf), generated with kicad-footprint-generator +connector JST PHD horizontal +0 +34 +34 +Connector_JST +JST_PH_B2B-PH-K_1x02_P2.00mm_Vertical +JST PH series connector, B2B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +2 +2 +Connector_JST +JST_PH_B2B-PH-SM4-TB_1x02-1MP_P2.00mm_Vertical +JST PH series connector, B2B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +4 +3 +Connector_JST +JST_PH_B3B-PH-K_1x03_P2.00mm_Vertical +JST PH series connector, B3B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +3 +3 +Connector_JST +JST_PH_B3B-PH-SM4-TB_1x03-1MP_P2.00mm_Vertical +JST PH series connector, B3B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +5 +4 +Connector_JST +JST_PH_B4B-PH-K_1x04_P2.00mm_Vertical +JST PH series connector, B4B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +4 +4 +Connector_JST +JST_PH_B4B-PH-SM4-TB_1x04-1MP_P2.00mm_Vertical +JST PH series connector, B4B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +6 +5 +Connector_JST +JST_PH_B5B-PH-K_1x05_P2.00mm_Vertical +JST PH series connector, B5B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +5 +5 +Connector_JST +JST_PH_B5B-PH-SM4-TB_1x05-1MP_P2.00mm_Vertical +JST PH series connector, B5B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +7 +6 +Connector_JST +JST_PH_B6B-PH-K_1x06_P2.00mm_Vertical +JST PH series connector, B6B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +6 +6 +Connector_JST +JST_PH_B6B-PH-SM4-TB_1x06-1MP_P2.00mm_Vertical +JST PH series connector, B6B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +8 +7 +Connector_JST +JST_PH_B7B-PH-K_1x07_P2.00mm_Vertical +JST PH series connector, B7B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +7 +7 +Connector_JST +JST_PH_B7B-PH-SM4-TB_1x07-1MP_P2.00mm_Vertical +JST PH series connector, B7B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +9 +8 +Connector_JST +JST_PH_B8B-PH-K_1x08_P2.00mm_Vertical +JST PH series connector, B8B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +8 +8 +Connector_JST +JST_PH_B8B-PH-SM4-TB_1x08-1MP_P2.00mm_Vertical +JST PH series connector, B8B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +10 +9 +Connector_JST +JST_PH_B9B-PH-K_1x09_P2.00mm_Vertical +JST PH series connector, B9B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +9 +9 +Connector_JST +JST_PH_B9B-PH-SM4-TB_1x09-1MP_P2.00mm_Vertical +JST PH series connector, B9B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +11 +10 +Connector_JST +JST_PH_B10B-PH-K_1x10_P2.00mm_Vertical +JST PH series connector, B10B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +10 +10 +Connector_JST +JST_PH_B10B-PH-SM4-TB_1x10-1MP_P2.00mm_Vertical +JST PH series connector, B10B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +12 +11 +Connector_JST +JST_PH_B11B-PH-K_1x11_P2.00mm_Vertical +JST PH series connector, B11B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +11 +11 +Connector_JST +JST_PH_B11B-PH-SM4-TB_1x11-1MP_P2.00mm_Vertical +JST PH series connector, B11B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +13 +12 +Connector_JST +JST_PH_B12B-PH-K_1x12_P2.00mm_Vertical +JST PH series connector, B12B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +12 +12 +Connector_JST +JST_PH_B12B-PH-SM4-TB_1x12-1MP_P2.00mm_Vertical +JST PH series connector, B12B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +14 +13 +Connector_JST +JST_PH_B13B-PH-K_1x13_P2.00mm_Vertical +JST PH series connector, B13B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +13 +13 +Connector_JST +JST_PH_B13B-PH-SM4-TB_1x13-1MP_P2.00mm_Vertical +JST PH series connector, B13B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +15 +14 +Connector_JST +JST_PH_B14B-PH-K_1x14_P2.00mm_Vertical +JST PH series connector, B14B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +14 +14 +Connector_JST +JST_PH_B14B-PH-SM4-TB_1x14-1MP_P2.00mm_Vertical +JST PH series connector, B14B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +16 +15 +Connector_JST +JST_PH_B15B-PH-K_1x15_P2.00mm_Vertical +JST PH series connector, B15B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +15 +15 +Connector_JST +JST_PH_B15B-PH-SM4-TB_1x15-1MP_P2.00mm_Vertical +JST PH series connector, B15B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +17 +16 +Connector_JST +JST_PH_B16B-PH-K_1x16_P2.00mm_Vertical +JST PH series connector, B16B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +16 +16 +Connector_JST +JST_PH_B16B-PH-SM4-TB_1x16-1MP_P2.00mm_Vertical +JST PH series connector, B16B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH side entry +0 +18 +17 +Connector_JST +JST_PH_S2B-PH-K_1x02_P2.00mm_Horizontal +JST PH series connector, S2B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +2 +2 +Connector_JST +JST_PH_S2B-PH-SM4-TB_1x02-1MP_P2.00mm_Horizontal +JST PH series connector, S2B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +4 +3 +Connector_JST +JST_PH_S3B-PH-K_1x03_P2.00mm_Horizontal +JST PH series connector, S3B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +3 +3 +Connector_JST +JST_PH_S3B-PH-SM4-TB_1x03-1MP_P2.00mm_Horizontal +JST PH series connector, S3B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +5 +4 +Connector_JST +JST_PH_S4B-PH-K_1x04_P2.00mm_Horizontal +JST PH series connector, S4B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +4 +4 +Connector_JST +JST_PH_S4B-PH-SM4-TB_1x04-1MP_P2.00mm_Horizontal +JST PH series connector, S4B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +6 +5 +Connector_JST +JST_PH_S5B-PH-K_1x05_P2.00mm_Horizontal +JST PH series connector, S5B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +5 +5 +Connector_JST +JST_PH_S5B-PH-SM4-TB_1x05-1MP_P2.00mm_Horizontal +JST PH series connector, S5B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +7 +6 +Connector_JST +JST_PH_S6B-PH-K_1x06_P2.00mm_Horizontal +JST PH series connector, S6B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +6 +6 +Connector_JST +JST_PH_S6B-PH-SM4-TB_1x06-1MP_P2.00mm_Horizontal +JST PH series connector, S6B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +8 +7 +Connector_JST +JST_PH_S7B-PH-K_1x07_P2.00mm_Horizontal +JST PH series connector, S7B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +7 +7 +Connector_JST +JST_PH_S7B-PH-SM4-TB_1x07-1MP_P2.00mm_Horizontal +JST PH series connector, S7B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +9 +8 +Connector_JST +JST_PH_S8B-PH-K_1x08_P2.00mm_Horizontal +JST PH series connector, S8B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +8 +8 +Connector_JST +JST_PH_S8B-PH-SM4-TB_1x08-1MP_P2.00mm_Horizontal +JST PH series connector, S8B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +10 +9 +Connector_JST +JST_PH_S9B-PH-K_1x09_P2.00mm_Horizontal +JST PH series connector, S9B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +9 +9 +Connector_JST +JST_PH_S9B-PH-SM4-TB_1x09-1MP_P2.00mm_Horizontal +JST PH series connector, S9B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +11 +10 +Connector_JST +JST_PH_S10B-PH-K_1x10_P2.00mm_Horizontal +JST PH series connector, S10B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +10 +10 +Connector_JST +JST_PH_S10B-PH-SM4-TB_1x10-1MP_P2.00mm_Horizontal +JST PH series connector, S10B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +12 +11 +Connector_JST +JST_PH_S11B-PH-K_1x11_P2.00mm_Horizontal +JST PH series connector, S11B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +11 +11 +Connector_JST +JST_PH_S11B-PH-SM4-TB_1x11-1MP_P2.00mm_Horizontal +JST PH series connector, S11B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +13 +12 +Connector_JST +JST_PH_S12B-PH-K_1x12_P2.00mm_Horizontal +JST PH series connector, S12B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +12 +12 +Connector_JST +JST_PH_S12B-PH-SM4-TB_1x12-1MP_P2.00mm_Horizontal +JST PH series connector, S12B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +14 +13 +Connector_JST +JST_PH_S13B-PH-K_1x13_P2.00mm_Horizontal +JST PH series connector, S13B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +13 +13 +Connector_JST +JST_PH_S13B-PH-SM4-TB_1x13-1MP_P2.00mm_Horizontal +JST PH series connector, S13B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +15 +14 +Connector_JST +JST_PH_S14B-PH-K_1x14_P2.00mm_Horizontal +JST PH series connector, S14B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +14 +14 +Connector_JST +JST_PH_S14B-PH-SM4-TB_1x14-1MP_P2.00mm_Horizontal +JST PH series connector, S14B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +16 +15 +Connector_JST +JST_PH_S15B-PH-K_1x15_P2.00mm_Horizontal +JST PH series connector, S15B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +15 +15 +Connector_JST +JST_PH_S15B-PH-SM4-TB_1x15-1MP_P2.00mm_Horizontal +JST PH series connector, S15B-PH-SM4-TB (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +17 +16 +Connector_JST +JST_PH_S16B-PH-K_1x16_P2.00mm_Horizontal +JST PH series connector, S16B-PH-K (http://www.jst-mfg.com/product/pdf/eng/ePH.pdf), generated with kicad-footprint-generator +connector JST PH top entry +0 +16 +16 +Connector_JST +JST_PUD_B08B-PUDSS_2x04_P2.00mm_Vertical +JST PUD series connector, B08B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +8 +8 +Connector_JST +JST_PUD_B10B-PUDSS_2x05_P2.00mm_Vertical +JST PUD series connector, B10B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +10 +10 +Connector_JST +JST_PUD_B12B-PUDSS_2x06_P2.00mm_Vertical +JST PUD series connector, B12B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +12 +12 +Connector_JST +JST_PUD_B14B-PUDSS_2x07_P2.00mm_Vertical +JST PUD series connector, B14B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +14 +14 +Connector_JST +JST_PUD_B16B-PUDSS_2x08_P2.00mm_Vertical +JST PUD series connector, B16B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +16 +16 +Connector_JST +JST_PUD_B18B-PUDSS_2x09_P2.00mm_Vertical +JST PUD series connector, B18B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +18 +18 +Connector_JST +JST_PUD_B20B-PUDSS_2x10_P2.00mm_Vertical +JST PUD series connector, B20B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +20 +20 +Connector_JST +JST_PUD_B22B-PUDSS_2x11_P2.00mm_Vertical +JST PUD series connector, B22B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +22 +22 +Connector_JST +JST_PUD_B24B-PUDSS_2x12_P2.00mm_Vertical +JST PUD series connector, B24B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +24 +24 +Connector_JST +JST_PUD_B26B-PUDSS_2x13_P2.00mm_Vertical +JST PUD series connector, B26B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +26 +26 +Connector_JST +JST_PUD_B28B-PUDSS_2x14_P2.00mm_Vertical +JST PUD series connector, B28B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +28 +28 +Connector_JST +JST_PUD_B30B-PUDSS_2x15_P2.00mm_Vertical +JST PUD series connector, B30B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +30 +30 +Connector_JST +JST_PUD_B32B-PUDSS_2x16_P2.00mm_Vertical +JST PUD series connector, B32B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +32 +32 +Connector_JST +JST_PUD_B34B-PUDSS_2x17_P2.00mm_Vertical +JST PUD series connector, B34B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +34 +34 +Connector_JST +JST_PUD_B36B-PUDSS_2x18_P2.00mm_Vertical +JST PUD series connector, B36B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +36 +36 +Connector_JST +JST_PUD_B38B-PUDSS_2x19_P2.00mm_Vertical +JST PUD series connector, B38B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +38 +38 +Connector_JST +JST_PUD_B40B-PUDSS_2x20_P2.00mm_Vertical +JST PUD series connector, B40B-PUDSS (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD side entry +0 +40 +40 +Connector_JST +JST_PUD_S08B-PUDSS-1_2x04_P2.00mm_Horizontal +JST PUD series connector, S08B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +8 +8 +Connector_JST +JST_PUD_S10B-PUDSS-1_2x05_P2.00mm_Horizontal +JST PUD series connector, S10B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +10 +10 +Connector_JST +JST_PUD_S12B-PUDSS-1_2x06_P2.00mm_Horizontal +JST PUD series connector, S12B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +12 +12 +Connector_JST +JST_PUD_S14B-PUDSS-1_2x07_P2.00mm_Horizontal +JST PUD series connector, S14B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +14 +14 +Connector_JST +JST_PUD_S16B-PUDSS-1_2x08_P2.00mm_Horizontal +JST PUD series connector, S16B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +16 +16 +Connector_JST +JST_PUD_S18B-PUDSS-1_2x09_P2.00mm_Horizontal +JST PUD series connector, S18B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +18 +18 +Connector_JST +JST_PUD_S20B-PUDSS-1_2x10_P2.00mm_Horizontal +JST PUD series connector, S20B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +20 +20 +Connector_JST +JST_PUD_S22B-PUDSS-1_2x11_P2.00mm_Horizontal +JST PUD series connector, S22B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +22 +22 +Connector_JST +JST_PUD_S24B-PUDSS-1_2x12_P2.00mm_Horizontal +JST PUD series connector, S24B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +24 +24 +Connector_JST +JST_PUD_S26B-PUDSS-1_2x13_P2.00mm_Horizontal +JST PUD series connector, S26B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +26 +26 +Connector_JST +JST_PUD_S28B-PUDSS-1_2x14_P2.00mm_Horizontal +JST PUD series connector, S28B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +28 +28 +Connector_JST +JST_PUD_S30B-PUDSS-1_2x15_P2.00mm_Horizontal +JST PUD series connector, S30B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +30 +30 +Connector_JST +JST_PUD_S32B-PUDSS-1_2x16_P2.00mm_Horizontal +JST PUD series connector, S32B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +32 +32 +Connector_JST +JST_PUD_S34B-PUDSS-1_2x17_P2.00mm_Horizontal +JST PUD series connector, S34B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +34 +34 +Connector_JST +JST_PUD_S36B-PUDSS-1_2x18_P2.00mm_Horizontal +JST PUD series connector, S36B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +36 +36 +Connector_JST +JST_PUD_S38B-PUDSS-1_2x19_P2.00mm_Horizontal +JST PUD series connector, S38B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +38 +38 +Connector_JST +JST_PUD_S40B-PUDSS-1_2x20_P2.00mm_Horizontal +JST PUD series connector, S40B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator +connector JST PUD top entry +0 +40 +40 +Connector_JST +JST_SFH_SM02B-SFHRS-TF_1x02-1MP_P4.20mm_Horizontal +JST SFH series connector, SM02B-SFHRS-TF (http://www.jst-mfg.com/product/pdf/eng/eSFH.pdf), generated with kicad-footprint-generator +connector JST SFH horizontal +0 +4 +3 +Connector_JST +JST_SHL_SM02B-SHLS-TF_1x02-1MP_P1.00mm_Horizontal +JST SHL series connector, SM02B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +4 +3 +Connector_JST +JST_SHL_SM05B-SHLS-TF_1x05-1MP_P1.00mm_Horizontal +JST SHL series connector, SM05B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +7 +6 +Connector_JST +JST_SHL_SM06B-SHLS-TF_1x06-1MP_P1.00mm_Horizontal +JST SHL series connector, SM06B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +8 +7 +Connector_JST +JST_SHL_SM07B-SHLS-TF_1x07-1MP_P1.00mm_Horizontal +JST SHL series connector, SM07B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +9 +8 +Connector_JST +JST_SHL_SM08B-SHLS-TF_1x08-1MP_P1.00mm_Horizontal +JST SHL series connector, SM08B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +10 +9 +Connector_JST +JST_SHL_SM10B-SHLS-TF_1x10-1MP_P1.00mm_Horizontal +JST SHL series connector, SM10B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +12 +11 +Connector_JST +JST_SHL_SM11B-SHLS-TF_1x11-1MP_P1.00mm_Horizontal +JST SHL series connector, SM11B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +13 +12 +Connector_JST +JST_SHL_SM12B-SHLS-TF_1x12-1MP_P1.00mm_Horizontal +JST SHL series connector, SM12B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +14 +13 +Connector_JST +JST_SHL_SM14B-SHLS-TF_1x14-1MP_P1.00mm_Horizontal +JST SHL series connector, SM14B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +16 +15 +Connector_JST +JST_SHL_SM16B-SHLS-TF_1x16-1MP_P1.00mm_Horizontal +JST SHL series connector, SM16B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +18 +17 +Connector_JST +JST_SHL_SM20B-SHLS-TF_1x20-1MP_P1.00mm_Horizontal +JST SHL series connector, SM20B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +22 +21 +Connector_JST +JST_SHL_SM22B-SHLS-TF_1x22-1MP_P1.00mm_Horizontal +JST SHL series connector, SM22B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +24 +23 +Connector_JST +JST_SHL_SM26B-SHLS-TF_1x26-1MP_P1.00mm_Horizontal +JST SHL series connector, SM26B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +28 +27 +Connector_JST +JST_SHL_SM30B-SHLS-TF_1x30-1MP_P1.00mm_Horizontal +JST SHL series connector, SM30B-SHLS-TF (http://www.jst-mfg.com/product/pdf/eng/eSHL.pdf), generated with kicad-footprint-generator +connector JST SHL top entry +0 +32 +31 +Connector_JST +JST_SH_BM02B-SRSS-TB_1x02-1MP_P1.00mm_Vertical +JST SH series connector, BM02B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +4 +3 +Connector_JST +JST_SH_BM03B-SRSS-TB_1x03-1MP_P1.00mm_Vertical +JST SH series connector, BM03B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +5 +4 +Connector_JST +JST_SH_BM04B-SRSS-TB_1x04-1MP_P1.00mm_Vertical +JST SH series connector, BM04B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +6 +5 +Connector_JST +JST_SH_BM05B-SRSS-TB_1x05-1MP_P1.00mm_Vertical +JST SH series connector, BM05B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +7 +6 +Connector_JST +JST_SH_BM06B-SRSS-TB_1x06-1MP_P1.00mm_Vertical +JST SH series connector, BM06B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +8 +7 +Connector_JST +JST_SH_BM07B-SRSS-TB_1x07-1MP_P1.00mm_Vertical +JST SH series connector, BM07B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +9 +8 +Connector_JST +JST_SH_BM08B-SRSS-TB_1x08-1MP_P1.00mm_Vertical +JST SH series connector, BM08B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +10 +9 +Connector_JST +JST_SH_BM09B-SRSS-TB_1x09-1MP_P1.00mm_Vertical +JST SH series connector, BM09B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +11 +10 +Connector_JST +JST_SH_BM10B-SRSS-TB_1x10-1MP_P1.00mm_Vertical +JST SH series connector, BM10B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +12 +11 +Connector_JST +JST_SH_BM11B-SRSS-TB_1x11-1MP_P1.00mm_Vertical +JST SH series connector, BM11B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +13 +12 +Connector_JST +JST_SH_BM12B-SRSS-TB_1x12-1MP_P1.00mm_Vertical +JST SH series connector, BM12B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +14 +13 +Connector_JST +JST_SH_BM13B-SRSS-TB_1x13-1MP_P1.00mm_Vertical +JST SH series connector, BM13B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +15 +14 +Connector_JST +JST_SH_BM14B-SRSS-TB_1x14-1MP_P1.00mm_Vertical +JST SH series connector, BM14B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +16 +15 +Connector_JST +JST_SH_BM15B-SRSS-TB_1x15-1MP_P1.00mm_Vertical +JST SH series connector, BM15B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH side entry +0 +17 +16 +Connector_JST +JST_SH_SM02B-SRSS-TB_1x02-1MP_P1.00mm_Horizontal +JST SH series connector, SM02B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +4 +3 +Connector_JST +JST_SH_SM03B-SRSS-TB_1x03-1MP_P1.00mm_Horizontal +JST SH series connector, SM03B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +5 +4 +Connector_JST +JST_SH_SM04B-SRSS-TB_1x04-1MP_P1.00mm_Horizontal +JST SH series connector, SM04B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +6 +5 +Connector_JST +JST_SH_SM05B-SRSS-TB_1x05-1MP_P1.00mm_Horizontal +JST SH series connector, SM05B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +7 +6 +Connector_JST +JST_SH_SM06B-SRSS-TB_1x06-1MP_P1.00mm_Horizontal +JST SH series connector, SM06B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +8 +7 +Connector_JST +JST_SH_SM07B-SRSS-TB_1x07-1MP_P1.00mm_Horizontal +JST SH series connector, SM07B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +9 +8 +Connector_JST +JST_SH_SM08B-SRSS-TB_1x08-1MP_P1.00mm_Horizontal +JST SH series connector, SM08B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +10 +9 +Connector_JST +JST_SH_SM09B-SRSS-TB_1x09-1MP_P1.00mm_Horizontal +JST SH series connector, SM09B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +11 +10 +Connector_JST +JST_SH_SM10B-SRSS-TB_1x10-1MP_P1.00mm_Horizontal +JST SH series connector, SM10B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +12 +11 +Connector_JST +JST_SH_SM11B-SRSS-TB_1x11-1MP_P1.00mm_Horizontal +JST SH series connector, SM11B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +13 +12 +Connector_JST +JST_SH_SM12B-SRSS-TB_1x12-1MP_P1.00mm_Horizontal +JST SH series connector, SM12B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +14 +13 +Connector_JST +JST_SH_SM13B-SRSS-TB_1x13-1MP_P1.00mm_Horizontal +JST SH series connector, SM13B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +15 +14 +Connector_JST +JST_SH_SM14B-SRSS-TB_1x14-1MP_P1.00mm_Horizontal +JST SH series connector, SM14B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +16 +15 +Connector_JST +JST_SH_SM15B-SRSS-TB_1x15-1MP_P1.00mm_Horizontal +JST SH series connector, SM15B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +17 +16 +Connector_JST +JST_SH_SM20B-SRSS-TB_1x20-1MP_P1.00mm_Horizontal +JST SH series connector, SM20B-SRSS-TB (http://www.jst-mfg.com/product/pdf/eng/eSH.pdf), generated with kicad-footprint-generator +connector JST SH top entry +0 +22 +21 +Connector_JST +JST_SUR_BM02B-SURS-TF_1x02-1MP_P0.80mm_Vertical +JST SUR series connector, BM02B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +4 +3 +Connector_JST +JST_SUR_BM03B-SURS-TF_1x03-1MP_P0.80mm_Vertical +JST SUR series connector, BM03B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +5 +4 +Connector_JST +JST_SUR_BM04B-SURS-TF_1x04-1MP_P0.80mm_Vertical +JST SUR series connector, BM04B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +6 +5 +Connector_JST +JST_SUR_BM05B-SURS-TF_1x05-1MP_P0.80mm_Vertical +JST SUR series connector, BM05B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +7 +6 +Connector_JST +JST_SUR_BM06B-SURS-TF_1x06-1MP_P0.80mm_Vertical +JST SUR series connector, BM06B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +8 +7 +Connector_JST +JST_SUR_BM08B-SURS-TF_1x08-1MP_P0.80mm_Vertical +JST SUR series connector, BM08B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +10 +9 +Connector_JST +JST_SUR_BM10B-SURS-TF_1x10-1MP_P0.80mm_Vertical +JST SUR series connector, BM10B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +12 +11 +Connector_JST +JST_SUR_BM12B-SURS-TF_1x12-1MP_P0.80mm_Vertical +JST SUR series connector, BM12B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +14 +13 +Connector_JST +JST_SUR_BM14B-SURS-TF_1x14-1MP_P0.80mm_Vertical +JST SUR series connector, BM14B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +16 +15 +Connector_JST +JST_SUR_BM15B-SURS-TF_1x15-1MP_P0.80mm_Vertical +JST SUR series connector, BM15B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +17 +16 +Connector_JST +JST_SUR_BM16B-SURS-TF_1x16-1MP_P0.80mm_Vertical +JST SUR series connector, BM16B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +18 +17 +Connector_JST +JST_SUR_BM17B-SURS-TF_1x17-1MP_P0.80mm_Vertical +JST SUR series connector, BM17B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +19 +18 +Connector_JST +JST_SUR_BM20B-SURS-TF_1x20-1MP_P0.80mm_Vertical +JST SUR series connector, BM20B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR side entry +0 +22 +21 +Connector_JST +JST_SUR_SM02B-SURS-TF_1x02-1MP_P0.80mm_Horizontal +JST SUR series connector, SM02B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +4 +3 +Connector_JST +JST_SUR_SM03B-SURS-TF_1x03-1MP_P0.80mm_Horizontal +JST SUR series connector, SM03B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +5 +4 +Connector_JST +JST_SUR_SM04B-SURS-TF_1x04-1MP_P0.80mm_Horizontal +JST SUR series connector, SM04B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +6 +5 +Connector_JST +JST_SUR_SM05B-SURS-TF_1x05-1MP_P0.80mm_Horizontal +JST SUR series connector, SM05B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +7 +6 +Connector_JST +JST_SUR_SM06B-SURS-TF_1x06-1MP_P0.80mm_Horizontal +JST SUR series connector, SM06B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +8 +7 +Connector_JST +JST_SUR_SM08B-SURS-TF_1x08-1MP_P0.80mm_Horizontal +JST SUR series connector, SM08B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +10 +9 +Connector_JST +JST_SUR_SM10B-SURS-TF_1x10-1MP_P0.80mm_Horizontal +JST SUR series connector, SM10B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +12 +11 +Connector_JST +JST_SUR_SM12B-SURS-TF_1x12-1MP_P0.80mm_Horizontal +JST SUR series connector, SM12B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +14 +13 +Connector_JST +JST_SUR_SM14B-SURS-TF_1x14-1MP_P0.80mm_Horizontal +JST SUR series connector, SM14B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +16 +15 +Connector_JST +JST_SUR_SM15B-SURS-TF_1x15-1MP_P0.80mm_Horizontal +JST SUR series connector, SM15B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +17 +16 +Connector_JST +JST_SUR_SM16B-SURS-TF_1x16-1MP_P0.80mm_Horizontal +JST SUR series connector, SM16B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +18 +17 +Connector_JST +JST_SUR_SM17B-SURS-TF_1x17-1MP_P0.80mm_Horizontal +JST SUR series connector, SM17B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +19 +18 +Connector_JST +JST_SUR_SM20B-SURS-TF_1x20-1MP_P0.80mm_Horizontal +JST SUR series connector, SM20B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +22 +21 +Connector_JST +JST_SUR_SM22B-SURS-TF_1x22-1MP_P0.80mm_Horizontal +JST SUR series connector, SM22B-SURS-TF (http://www.jst-mfg.com/product/pdf/eng/eSUR.pdf), generated with kicad-footprint-generator +connector JST SUR top entry +0 +24 +23 +Connector_JST +JST_VH_B2P-VH-B_1x02_P3.96mm_Vertical +JST VH PBT series connector, B2P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +2 +2 +Connector_JST +JST_VH_B2P-VH-FB-B_1x02_P3.96mm_Vertical +JST VH series connector, B2P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +2 +2 +Connector_JST +JST_VH_B2P-VH_1x02_P3.96mm_Vertical +JST VH series connector, B2P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +2 +2 +Connector_JST +JST_VH_B2P3-VH_1x02_P7.92mm_Vertical +JST VH series connector, B2P3-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +2 +2 +Connector_JST +JST_VH_B2PS-VH_1x02_P3.96mm_Horizontal +JST VH series connector, B2PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +2 +2 +Connector_JST +JST_VH_B3P-VH-B_1x03_P3.96mm_Vertical +JST VH PBT series connector, B3P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +3 +3 +Connector_JST +JST_VH_B3P-VH-FB-B_1x03_P3.96mm_Vertical +JST VH series connector, B3P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +3 +3 +Connector_JST +JST_VH_B3P-VH_1x03_P3.96mm_Vertical +JST VH series connector, B3P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +3 +3 +Connector_JST +JST_VH_B3PS-VH_1x03_P3.96mm_Horizontal +JST VH series connector, B3PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +3 +3 +Connector_JST +JST_VH_B4P-VH-B_1x04_P3.96mm_Vertical +JST VH PBT series connector, B4P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +4 +4 +Connector_JST +JST_VH_B4P-VH-FB-B_1x04_P3.96mm_Vertical +JST VH series connector, B4P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +4 +4 +Connector_JST +JST_VH_B4P-VH_1x04_P3.96mm_Vertical +JST VH series connector, B4P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +4 +4 +Connector_JST +JST_VH_B4PS-VH_1x04_P3.96mm_Horizontal +JST VH series connector, B4PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +4 +4 +Connector_JST +JST_VH_B5P-VH-B_1x05_P3.96mm_Vertical +JST VH PBT series connector, B5P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +5 +5 +Connector_JST +JST_VH_B5P-VH-FB-B_1x05_P3.96mm_Vertical +JST VH series connector, B5P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +5 +5 +Connector_JST +JST_VH_B5P-VH_1x05_P3.96mm_Vertical +JST VH series connector, B5P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +5 +5 +Connector_JST +JST_VH_B5PS-VH_1x05_P3.96mm_Horizontal +JST VH series connector, B5PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +5 +5 +Connector_JST +JST_VH_B6P-VH-B_1x06_P3.96mm_Vertical +JST VH PBT series connector, B6P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +6 +6 +Connector_JST +JST_VH_B6P-VH-FB-B_1x06_P3.96mm_Vertical +JST VH series connector, B6P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +6 +6 +Connector_JST +JST_VH_B6P-VH_1x06_P3.96mm_Vertical +JST VH series connector, B6P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +6 +6 +Connector_JST +JST_VH_B6PS-VH_1x06_P3.96mm_Horizontal +JST VH series connector, B6PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +6 +6 +Connector_JST +JST_VH_B7P-VH-B_1x07_P3.96mm_Vertical +JST VH PBT series connector, B7P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +7 +7 +Connector_JST +JST_VH_B7P-VH-FB-B_1x07_P3.96mm_Vertical +JST VH series connector, B7P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +7 +7 +Connector_JST +JST_VH_B7P-VH_1x07_P3.96mm_Vertical +JST VH series connector, B7P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +7 +7 +Connector_JST +JST_VH_B7PS-VH_1x07_P3.96mm_Horizontal +JST VH series connector, B7PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +7 +7 +Connector_JST +JST_VH_B8P-VH-B_1x08_P3.96mm_Vertical +JST VH PBT series connector, B8P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +8 +8 +Connector_JST +JST_VH_B8P-VH-FB-B_1x08_P3.96mm_Vertical +JST VH series connector, B8P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +8 +8 +Connector_JST +JST_VH_B8P-VH_1x08_P3.96mm_Vertical +JST VH series connector, B8P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +8 +8 +Connector_JST +JST_VH_B8PS-VH_1x08_P3.96mm_Horizontal +JST VH series connector, B8PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +8 +8 +Connector_JST +JST_VH_B9P-VH-B_1x09_P3.96mm_Vertical +JST VH PBT series connector, B9P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +9 +9 +Connector_JST +JST_VH_B9P-VH-FB-B_1x09_P3.96mm_Vertical +JST VH series connector, B9P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +9 +9 +Connector_JST +JST_VH_B9P-VH_1x09_P3.96mm_Vertical +JST VH series connector, B9P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +9 +9 +Connector_JST +JST_VH_B9PS-VH_1x09_P3.96mm_Horizontal +JST VH series connector, B9PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +9 +9 +Connector_JST +JST_VH_B10P-VH-B_1x10_P3.96mm_Vertical +JST VH PBT series connector, B10P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +10 +10 +Connector_JST +JST_VH_B10P-VH-FB-B_1x10_P3.96mm_Vertical +JST VH series connector, B10P-VH-FB-B, shrouded (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH side entry +0 +10 +10 +Connector_JST +JST_VH_B10P-VH_1x10_P3.96mm_Vertical +JST VH series connector, B10P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +10 +10 +Connector_JST +JST_VH_B10PS-VH_1x10_P3.96mm_Horizontal +JST VH series connector, B10PS-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +10 +10 +Connector_JST +JST_VH_B11P-VH-B_1x11_P3.96mm_Vertical +JST VH PBT series connector, B11P-VH-B (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH vertical +0 +11 +11 +Connector_JST +JST_VH_S2P-VH_1x02_P3.96mm_Horizontal +JST VH series connector, S2P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +2 +2 +Connector_JST +JST_VH_S3P-VH_1x03_P3.96mm_Horizontal +JST VH series connector, S3P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +3 +3 +Connector_JST +JST_VH_S4P-VH_1x04_P3.96mm_Horizontal +JST VH series connector, S4P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +4 +4 +Connector_JST +JST_VH_S5P-VH_1x05_P3.96mm_Horizontal +JST VH series connector, S5P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +5 +5 +Connector_JST +JST_VH_S6P-VH_1x06_P3.96mm_Horizontal +JST VH series connector, S6P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +6 +6 +Connector_JST +JST_VH_S7P-VH_1x07_P3.96mm_Horizontal +JST VH series connector, S7P-VH (http://www.jst-mfg.com/product/pdf/eng/eVH.pdf), generated with kicad-footprint-generator +connector JST VH top entry +0 +7 +7 +Connector_JST +JST_XAG_SM05B-XAGKS-BN-TB_1x05-1MP_P2.50mm_Horizontal +JST XAG series connector, SM05B-XAGKS-BN-TB (http://www.jst-mfg.com/product/pdf/eng/eXAG.pdf), generated with kicad-footprint-generator +connector JST XAG top entry +0 +7 +6 +Connector_JST +JST_XH_B1B-XH-AM_1x01_P2.50mm_Vertical +JST XH series connector, B1B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +1 +1 +Connector_JST +JST_XH_B2B-XH-AM_1x02_P2.50mm_Vertical +JST XH series connector, B2B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +2 +2 +Connector_JST +JST_XH_B2B-XH-A_1x02_P2.50mm_Vertical +JST XH series connector, B2B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +2 +2 +Connector_JST +JST_XH_B3B-XH-AM_1x03_P2.50mm_Vertical +JST XH series connector, B3B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +3 +3 +Connector_JST +JST_XH_B3B-XH-A_1x03_P2.50mm_Vertical +JST XH series connector, B3B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +3 +3 +Connector_JST +JST_XH_B4B-XH-AM_1x04_P2.50mm_Vertical +JST XH series connector, B4B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +4 +4 +Connector_JST +JST_XH_B4B-XH-A_1x04_P2.50mm_Vertical +JST XH series connector, B4B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +4 +4 +Connector_JST +JST_XH_B5B-XH-AM_1x05_P2.50mm_Vertical +JST XH series connector, B5B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +5 +5 +Connector_JST +JST_XH_B5B-XH-A_1x05_P2.50mm_Vertical +JST XH series connector, B5B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +5 +5 +Connector_JST +JST_XH_B6B-XH-AM_1x06_P2.50mm_Vertical +JST XH series connector, B6B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +6 +6 +Connector_JST +JST_XH_B6B-XH-A_1x06_P2.50mm_Vertical +JST XH series connector, B6B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +6 +6 +Connector_JST +JST_XH_B7B-XH-AM_1x07_P2.50mm_Vertical +JST XH series connector, B7B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +7 +7 +Connector_JST +JST_XH_B7B-XH-A_1x07_P2.50mm_Vertical +JST XH series connector, B7B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +7 +7 +Connector_JST +JST_XH_B8B-XH-AM_1x08_P2.50mm_Vertical +JST XH series connector, B8B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +8 +8 +Connector_JST +JST_XH_B8B-XH-A_1x08_P2.50mm_Vertical +JST XH series connector, B8B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +8 +8 +Connector_JST +JST_XH_B9B-XH-AM_1x09_P2.50mm_Vertical +JST XH series connector, B9B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical boss +0 +9 +9 +Connector_JST +JST_XH_B9B-XH-A_1x09_P2.50mm_Vertical +JST XH series connector, B9B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH vertical +0 +9 +9 +Connector_JST +JST_XH_B10B-XH-AM_1x10_P2.50mm_Vertical +JST XH series connector, B10B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry boss +0 +10 +10 +Connector_JST +JST_XH_B10B-XH-A_1x10_P2.50mm_Vertical +JST XH series connector, B10B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +10 +10 +Connector_JST +JST_XH_B11B-XH-A_1x11_P2.50mm_Vertical +JST XH series connector, B11B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +11 +11 +Connector_JST +JST_XH_B12B-XH-AM_1x12_P2.50mm_Vertical +JST XH series connector, B12B-XH-AM, with boss (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry boss +0 +12 +12 +Connector_JST +JST_XH_B12B-XH-A_1x12_P2.50mm_Vertical +JST XH series connector, B12B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +12 +12 +Connector_JST +JST_XH_B13B-XH-A_1x13_P2.50mm_Vertical +JST XH series connector, B13B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +13 +13 +Connector_JST +JST_XH_B14B-XH-A_1x14_P2.50mm_Vertical +JST XH series connector, B14B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +14 +14 +Connector_JST +JST_XH_B15B-XH-A_1x15_P2.50mm_Vertical +JST XH series connector, B15B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +15 +15 +Connector_JST +JST_XH_B16B-XH-A_1x16_P2.50mm_Vertical +JST XH series connector, B16B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +16 +16 +Connector_JST +JST_XH_B20B-XH-A_1x20_P2.50mm_Vertical +JST XH series connector, B20B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH side entry +0 +20 +20 +Connector_JST +JST_XH_S2B-XH-A-1_1x02_P2.50mm_Horizontal +JST XH series connector, S2B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +2 +2 +Connector_JST +JST_XH_S2B-XH-A_1x02_P2.50mm_Horizontal +JST XH series connector, S2B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +2 +2 +Connector_JST +JST_XH_S3B-XH-A-1_1x03_P2.50mm_Horizontal +JST XH series connector, S3B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +3 +3 +Connector_JST +JST_XH_S3B-XH-A_1x03_P2.50mm_Horizontal +JST XH series connector, S3B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +3 +3 +Connector_JST +JST_XH_S4B-XH-A-1_1x04_P2.50mm_Horizontal +JST XH series connector, S4B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +4 +4 +Connector_JST +JST_XH_S4B-XH-A_1x04_P2.50mm_Horizontal +JST XH series connector, S4B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +4 +4 +Connector_JST +JST_XH_S5B-XH-A-1_1x05_P2.50mm_Horizontal +JST XH series connector, S5B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +5 +5 +Connector_JST +JST_XH_S5B-XH-A_1x05_P2.50mm_Horizontal +JST XH series connector, S5B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +5 +5 +Connector_JST +JST_XH_S6B-XH-A-1_1x06_P2.50mm_Horizontal +JST XH series connector, S6B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +6 +6 +Connector_JST +JST_XH_S6B-XH-A_1x06_P2.50mm_Horizontal +JST XH series connector, S6B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +6 +6 +Connector_JST +JST_XH_S7B-XH-A-1_1x07_P2.50mm_Horizontal +JST XH series connector, S7B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +7 +7 +Connector_JST +JST_XH_S7B-XH-A_1x07_P2.50mm_Horizontal +JST XH series connector, S7B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +7 +7 +Connector_JST +JST_XH_S8B-XH-A-1_1x08_P2.50mm_Horizontal +JST XH series connector, S8B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +8 +8 +Connector_JST +JST_XH_S8B-XH-A_1x08_P2.50mm_Horizontal +JST XH series connector, S8B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +8 +8 +Connector_JST +JST_XH_S9B-XH-A-1_1x09_P2.50mm_Horizontal +JST XH series connector, S9B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +9 +9 +Connector_JST +JST_XH_S9B-XH-A_1x09_P2.50mm_Horizontal +JST XH series connector, S9B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH horizontal +0 +9 +9 +Connector_JST +JST_XH_S10B-XH-A-1_1x10_P2.50mm_Horizontal +JST XH series connector, S10B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +10 +10 +Connector_JST +JST_XH_S10B-XH-A_1x10_P2.50mm_Horizontal +JST XH series connector, S10B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +10 +10 +Connector_JST +JST_XH_S11B-XH-A-1_1x11_P2.50mm_Horizontal +JST XH series connector, S11B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +11 +11 +Connector_JST +JST_XH_S11B-XH-A_1x11_P2.50mm_Horizontal +JST XH series connector, S11B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +11 +11 +Connector_JST +JST_XH_S12B-XH-A-1_1x12_P2.50mm_Horizontal +JST XH series connector, S12B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +12 +12 +Connector_JST +JST_XH_S12B-XH-A_1x12_P2.50mm_Horizontal +JST XH series connector, S12B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +12 +12 +Connector_JST +JST_XH_S13B-XH-A-1_1x13_P2.50mm_Horizontal +JST XH series connector, S13B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +13 +13 +Connector_JST +JST_XH_S13B-XH-A_1x13_P2.50mm_Horizontal +JST XH series connector, S13B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +13 +13 +Connector_JST +JST_XH_S14B-XH-A-1_1x14_P2.50mm_Horizontal +JST XH series connector, S14B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +14 +14 +Connector_JST +JST_XH_S14B-XH-A_1x14_P2.50mm_Horizontal +JST XH series connector, S14B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +14 +14 +Connector_JST +JST_XH_S15B-XH-A-1_1x15_P2.50mm_Horizontal +JST XH series connector, S15B-XH-A-1 (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +15 +15 +Connector_JST +JST_XH_S15B-XH-A_1x15_P2.50mm_Horizontal +JST XH series connector, S15B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +15 +15 +Connector_JST +JST_XH_S16B-XH-A_1x16_P2.50mm_Horizontal +JST XH series connector, S16B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator +connector JST XH top entry +0 +16 +16 +Connector_JST +JST_ZE_B02B-ZESK-1D_1x02_P1.50mm_Vertical +JST ZE series connector, B02B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +2 +2 +Connector_JST +JST_ZE_B03B-ZESK-1D_1x03_P1.50mm_Vertical +JST ZE series connector, B03B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +3 +3 +Connector_JST +JST_ZE_B03B-ZESK-D_1x03_P1.50mm_Vertical +JST ZE series connector, B03B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +3 +3 +Connector_JST +JST_ZE_B04B-ZESK-1D_1x04_P1.50mm_Vertical +JST ZE series connector, B04B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +4 +4 +Connector_JST +JST_ZE_B04B-ZESK-D_1x04_P1.50mm_Vertical +JST ZE series connector, B04B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +4 +4 +Connector_JST +JST_ZE_B05B-ZESK-1D_1x05_P1.50mm_Vertical +JST ZE series connector, B05B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +5 +5 +Connector_JST +JST_ZE_B05B-ZESK-D_1x05_P1.50mm_Vertical +JST ZE series connector, B05B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +5 +5 +Connector_JST +JST_ZE_B06B-ZESK-1D_1x06_P1.50mm_Vertical +JST ZE series connector, B06B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +6 +6 +Connector_JST +JST_ZE_B06B-ZESK-D_1x06_P1.50mm_Vertical +JST ZE series connector, B06B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +6 +6 +Connector_JST +JST_ZE_B07B-ZESK-1D_1x07_P1.50mm_Vertical +JST ZE series connector, B07B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +7 +7 +Connector_JST +JST_ZE_B07B-ZESK-D_1x07_P1.50mm_Vertical +JST ZE series connector, B07B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +7 +7 +Connector_JST +JST_ZE_B08B-ZESK-1D_1x08_P1.50mm_Vertical +JST ZE series connector, B08B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +8 +8 +Connector_JST +JST_ZE_B08B-ZESK-D_1x08_P1.50mm_Vertical +JST ZE series connector, B08B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +8 +8 +Connector_JST +JST_ZE_B09B-ZESK-1D_1x09_P1.50mm_Vertical +JST ZE series connector, B09B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +9 +9 +Connector_JST +JST_ZE_B09B-ZESK-D_1x09_P1.50mm_Vertical +JST ZE series connector, B09B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +9 +9 +Connector_JST +JST_ZE_B10B-ZESK-1D_1x10_P1.50mm_Vertical +JST ZE series connector, B10B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +10 +10 +Connector_JST +JST_ZE_B10B-ZESK-D_1x10_P1.50mm_Vertical +JST ZE series connector, B10B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +10 +10 +Connector_JST +JST_ZE_B11B-ZESK-1D_1x11_P1.50mm_Vertical +JST ZE series connector, B11B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +11 +11 +Connector_JST +JST_ZE_B11B-ZESK-D_1x11_P1.50mm_Vertical +JST ZE series connector, B11B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +11 +11 +Connector_JST +JST_ZE_B12B-ZESK-1D_1x12_P1.50mm_Vertical +JST ZE series connector, B12B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +12 +12 +Connector_JST +JST_ZE_B12B-ZESK-D_1x12_P1.50mm_Vertical +JST ZE series connector, B12B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +12 +12 +Connector_JST +JST_ZE_B13B-ZESK-1D_1x13_P1.50mm_Vertical +JST ZE series connector, B13B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +13 +13 +Connector_JST +JST_ZE_B13B-ZESK-D_1x13_P1.50mm_Vertical +JST ZE series connector, B13B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +13 +13 +Connector_JST +JST_ZE_B14B-ZESK-1D_1x14_P1.50mm_Vertical +JST ZE series connector, B14B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +14 +14 +Connector_JST +JST_ZE_B14B-ZESK-D_1x14_P1.50mm_Vertical +JST ZE series connector, B14B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +14 +14 +Connector_JST +JST_ZE_B15B-ZESK-1D_1x15_P1.50mm_Vertical +JST ZE series connector, B15B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +15 +15 +Connector_JST +JST_ZE_B15B-ZESK-D_1x15_P1.50mm_Vertical +JST ZE series connector, B15B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +15 +15 +Connector_JST +JST_ZE_B16B-ZESK-1D_1x16_P1.50mm_Vertical +JST ZE series connector, B16B-ZESK-1D, with boss (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry boss +0 +16 +16 +Connector_JST +JST_ZE_B16B-ZESK-D_1x16_P1.50mm_Vertical +JST ZE series connector, B16B-ZESK-D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE side entry +0 +16 +16 +Connector_JST +JST_ZE_BM02B-ZESS-TBT_1x02-1MP_P1.50mm_Vertical +JST ZE series connector, BM02B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +4 +3 +Connector_JST +JST_ZE_BM03B-ZESS-TBT_1x03-1MP_P1.50mm_Vertical +JST ZE series connector, BM03B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +5 +4 +Connector_JST +JST_ZE_BM04B-ZESS-TBT_1x04-1MP_P1.50mm_Vertical +JST ZE series connector, BM04B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +6 +5 +Connector_JST +JST_ZE_BM05B-ZESS-TBT_1x05-1MP_P1.50mm_Vertical +JST ZE series connector, BM05B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +7 +6 +Connector_JST +JST_ZE_BM06B-ZESS-TBT_1x06-1MP_P1.50mm_Vertical +JST ZE series connector, BM06B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +8 +7 +Connector_JST +JST_ZE_BM07B-ZESS-TBT_1x07-1MP_P1.50mm_Vertical +JST ZE series connector, BM07B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +9 +8 +Connector_JST +JST_ZE_BM08B-ZESS-TBT_1x08-1MP_P1.50mm_Vertical +JST ZE series connector, BM08B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +10 +9 +Connector_JST +JST_ZE_BM09B-ZESS-TBT_1x09-1MP_P1.50mm_Vertical +JST ZE series connector, BM09B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +11 +10 +Connector_JST +JST_ZE_BM10B-ZESS-TBT_1x10-1MP_P1.50mm_Vertical +JST ZE series connector, BM10B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +12 +11 +Connector_JST +JST_ZE_BM11B-ZESS-TBT_1x11-1MP_P1.50mm_Vertical +JST ZE series connector, BM11B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +13 +12 +Connector_JST +JST_ZE_BM12B-ZESS-TBT_1x12-1MP_P1.50mm_Vertical +JST ZE series connector, BM12B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +14 +13 +Connector_JST +JST_ZE_BM13B-ZESS-TBT_1x13-1MP_P1.50mm_Vertical +JST ZE series connector, BM13B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +15 +14 +Connector_JST +JST_ZE_BM14B-ZESS-TBT_1x14-1MP_P1.50mm_Vertical +JST ZE series connector, BM14B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +16 +15 +Connector_JST +JST_ZE_BM15B-ZESS-TBT_1x15-1MP_P1.50mm_Vertical +JST ZE series connector, BM15B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +17 +16 +Connector_JST +JST_ZE_BM16B-ZESS-TBT_1x16-1MP_P1.50mm_Vertical +JST ZE series connector, BM16B-ZESS-TBT (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE vertical +0 +18 +17 +Connector_JST +JST_ZE_S02B-ZESK-2D_1x02_P1.50mm_Horizontal +JST ZE series connector, S02B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +2 +2 +Connector_JST +JST_ZE_S03B-ZESK-2D_1x03_P1.50mm_Horizontal +JST ZE series connector, S03B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +3 +3 +Connector_JST +JST_ZE_S04B-ZESK-2D_1x04_P1.50mm_Horizontal +JST ZE series connector, S04B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +4 +4 +Connector_JST +JST_ZE_S05B-ZESK-2D_1x05_P1.50mm_Horizontal +JST ZE series connector, S05B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +5 +5 +Connector_JST +JST_ZE_S06B-ZESK-2D_1x06_P1.50mm_Horizontal +JST ZE series connector, S06B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +6 +6 +Connector_JST +JST_ZE_S07B-ZESK-2D_1x07_P1.50mm_Horizontal +JST ZE series connector, S07B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +7 +7 +Connector_JST +JST_ZE_S08B-ZESK-2D_1x08_P1.50mm_Horizontal +JST ZE series connector, S08B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +8 +8 +Connector_JST +JST_ZE_S09B-ZESK-2D_1x09_P1.50mm_Horizontal +JST ZE series connector, S09B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +9 +9 +Connector_JST +JST_ZE_S10B-ZESK-2D_1x10_P1.50mm_Horizontal +JST ZE series connector, S10B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +10 +10 +Connector_JST +JST_ZE_S11B-ZESK-2D_1x11_P1.50mm_Horizontal +JST ZE series connector, S11B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +11 +11 +Connector_JST +JST_ZE_S12B-ZESK-2D_1x12_P1.50mm_Horizontal +JST ZE series connector, S12B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +12 +12 +Connector_JST +JST_ZE_S13B-ZESK-2D_1x13_P1.50mm_Horizontal +JST ZE series connector, S13B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +13 +13 +Connector_JST +JST_ZE_S14B-ZESK-2D_1x14_P1.50mm_Horizontal +JST ZE series connector, S14B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +14 +14 +Connector_JST +JST_ZE_S15B-ZESK-2D_1x15_P1.50mm_Horizontal +JST ZE series connector, S15B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +15 +15 +Connector_JST +JST_ZE_S16B-ZESK-2D_1x16_P1.50mm_Horizontal +JST ZE series connector, S16B-ZESK-2D (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE top entry +0 +16 +16 +Connector_JST +JST_ZE_SM02B-ZESS-TB_1x02-1MP_P1.50mm_Horizontal +JST ZE series connector, SM02B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +4 +3 +Connector_JST +JST_ZE_SM03B-ZESS-TB_1x03-1MP_P1.50mm_Horizontal +JST ZE series connector, SM03B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +5 +4 +Connector_JST +JST_ZE_SM04B-ZESS-TB_1x04-1MP_P1.50mm_Horizontal +JST ZE series connector, SM04B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +6 +5 +Connector_JST +JST_ZE_SM05B-ZESS-TB_1x05-1MP_P1.50mm_Horizontal +JST ZE series connector, SM05B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +7 +6 +Connector_JST +JST_ZE_SM06B-ZESS-TB_1x06-1MP_P1.50mm_Horizontal +JST ZE series connector, SM06B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +8 +7 +Connector_JST +JST_ZE_SM07B-ZESS-TB_1x07-1MP_P1.50mm_Horizontal +JST ZE series connector, SM07B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +9 +8 +Connector_JST +JST_ZE_SM08B-ZESS-TB_1x08-1MP_P1.50mm_Horizontal +JST ZE series connector, SM08B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +10 +9 +Connector_JST +JST_ZE_SM09B-ZESS-TB_1x09-1MP_P1.50mm_Horizontal +JST ZE series connector, SM09B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +11 +10 +Connector_JST +JST_ZE_SM10B-ZESS-TB_1x10-1MP_P1.50mm_Horizontal +JST ZE series connector, SM10B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +12 +11 +Connector_JST +JST_ZE_SM11B-ZESS-TB_1x11-1MP_P1.50mm_Horizontal +JST ZE series connector, SM11B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +13 +12 +Connector_JST +JST_ZE_SM12B-ZESS-TB_1x12-1MP_P1.50mm_Horizontal +JST ZE series connector, SM12B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +14 +13 +Connector_JST +JST_ZE_SM13B-ZESS-TB_1x13-1MP_P1.50mm_Horizontal +JST ZE series connector, SM13B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +15 +14 +Connector_JST +JST_ZE_SM14B-ZESS-TB_1x14-1MP_P1.50mm_Horizontal +JST ZE series connector, SM14B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +16 +15 +Connector_JST +JST_ZE_SM15B-ZESS-TB_1x15-1MP_P1.50mm_Horizontal +JST ZE series connector, SM15B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +17 +16 +Connector_JST +JST_ZE_SM16B-ZESS-TB_1x16-1MP_P1.50mm_Horizontal +JST ZE series connector, SM16B-ZESS-TB (http://www.jst-mfg.com/product/pdf/eng/eZE.pdf), generated with kicad-footprint-generator +connector JST ZE horizontal +0 +18 +17 +Connector_Molex +Molex_CLIK-Mate_502382-0270_1x02-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0270 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502382-0370_1x03-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0370 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502382-0470_1x04-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0470 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502382-0570_1x05-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0570 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502382-0670_1x06-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0670 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502382-0770_1x07-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0770 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502382-0870_1x08-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0870 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502382-0970_1x09-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-0970 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502382-1070_1x10-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1070 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502382-1170_1x11-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1170 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_502382-1270_1x12-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1270 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502382-1370_1x13-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1370 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502382-1470_1x14-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1470 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502382-1570_1x15-1MP_P1.25mm_Vertical +Molex CLIK-Mate series connector, 502382-1570 (http://www.molex.com/pdm_docs/sd/5023820270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502386-0270_1x02-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0270 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502386-0370_1x03-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0370 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502386-0470_1x04-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0470 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502386-0570_1x05-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0570 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502386-0670_1x06-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0670 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502386-0770_1x07-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0770 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502386-0870_1x08-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0870 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502386-0970_1x09-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-0970 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502386-1070_1x10-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1070 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502386-1170_1x11-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1170 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_502386-1270_1x12-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1270 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502386-1370_1x13-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1370 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502386-1470_1x14-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1470 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502386-1570_1x15-1MP_P1.25mm_Horizontal +Molex CLIK-Mate series connector, 502386-1570 (http://www.molex.com/pdm_docs/sd/5023860270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502443-0270_1x02-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0270 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502443-0370_1x03-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0370 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502443-0470_1x04-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0470 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502443-0570_1x05-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0570 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502443-0670_1x06-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0670 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502443-0770_1x07-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0770 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502443-0870_1x08-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0870 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502443-0970_1x09-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-0970 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502443-1270_1x12-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1270 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502443-1370_1x13-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1370 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502443-1470_1x14-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1470 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502443-1570_1x15-1MP_P2.00mm_Vertical +Molex CLIK-Mate series connector, 502443-1570 (http://www.molex.com/pdm_docs/sd/5024430270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502494-0270_1x02-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0270 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502494-0370_1x03-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0370 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502494-0470_1x04-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0470 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502494-0670_1x06-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0670 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502494-0870_1x08-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-0870 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502494-1070_1x10-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1070 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502494-1270_1x12-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1270 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502494-1370_1x13-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1370 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502494-1470_1x14-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1470 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502494-1570_1x15-1MP_P2.00mm_Horizontal +Molex CLIK-Mate series connector, 502494-1570 (http://www.molex.com/pdm_docs/sd/5024940270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_502585-0270_1x02-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0270 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_502585-0370_1x03-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0370 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_502585-0470_1x04-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0470 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_502585-0570_1x05-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0570 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_502585-0670_1x06-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0670 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_502585-0770_1x07-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0770 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_502585-0870_1x08-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0870 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_502585-0970_1x09-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-0970 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_502585-1070_1x10-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1070 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_502585-1170_1x11-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1170 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_502585-1270_1x12-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1270 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_502585-1370_1x13-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1370 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_502585-1470_1x14-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1470 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_502585-1570_1x15-1MP_P1.50mm_Horizontal +Molex CLIK-Mate series connector, 502585-1570 (http://www.molex.com/pdm_docs/sd/5025850270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate top entry +0 +17 +16 +Connector_Molex +Molex_CLIK-Mate_505405-0270_1x02-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0270 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +4 +3 +Connector_Molex +Molex_CLIK-Mate_505405-0370_1x03-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0370 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +5 +4 +Connector_Molex +Molex_CLIK-Mate_505405-0470_1x04-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0470 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +6 +5 +Connector_Molex +Molex_CLIK-Mate_505405-0570_1x05-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0570 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +7 +6 +Connector_Molex +Molex_CLIK-Mate_505405-0670_1x06-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0670 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +8 +7 +Connector_Molex +Molex_CLIK-Mate_505405-0770_1x07-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0770 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +9 +8 +Connector_Molex +Molex_CLIK-Mate_505405-0870_1x08-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0870 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +10 +9 +Connector_Molex +Molex_CLIK-Mate_505405-0970_1x09-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-0970 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +11 +10 +Connector_Molex +Molex_CLIK-Mate_505405-1070_1x10-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1070 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +12 +11 +Connector_Molex +Molex_CLIK-Mate_505405-1170_1x11-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1170 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +13 +12 +Connector_Molex +Molex_CLIK-Mate_505405-1270_1x12-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1270 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +14 +13 +Connector_Molex +Molex_CLIK-Mate_505405-1370_1x13-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1370 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +15 +14 +Connector_Molex +Molex_CLIK-Mate_505405-1470_1x14-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1470 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +16 +15 +Connector_Molex +Molex_CLIK-Mate_505405-1570_1x15-1MP_P1.50mm_Vertical +Molex CLIK-Mate series connector, 505405-1570 (http://www.molex.com/pdm_docs/sd/5054050270_sd.pdf), generated with kicad-footprint-generator +connector Molex CLIK-Mate side entry +0 +17 +16 +Connector_Molex +Molex_KK-254_AE-6410-02A_1x02_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-02A example for new part number: 22-27-2021, 2 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +2 +2 +Connector_Molex +Molex_KK-254_AE-6410-03A_1x03_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-03A example for new part number: 22-27-2031, 3 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +3 +3 +Connector_Molex +Molex_KK-254_AE-6410-04A_1x04_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-04A example for new part number: 22-27-2041, 4 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +4 +4 +Connector_Molex +Molex_KK-254_AE-6410-05A_1x05_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-05A example for new part number: 22-27-2051, 5 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +5 +5 +Connector_Molex +Molex_KK-254_AE-6410-06A_1x06_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-06A example for new part number: 22-27-2061, 6 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +6 +6 +Connector_Molex +Molex_KK-254_AE-6410-07A_1x07_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-07A example for new part number: 22-27-2071, 7 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +7 +7 +Connector_Molex +Molex_KK-254_AE-6410-08A_1x08_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-08A example for new part number: 22-27-2081, 8 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +8 +8 +Connector_Molex +Molex_KK-254_AE-6410-09A_1x09_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-09A example for new part number: 22-27-2091, 9 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +9 +9 +Connector_Molex +Molex_KK-254_AE-6410-10A_1x10_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-10A example for new part number: 22-27-2101, 10 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +10 +10 +Connector_Molex +Molex_KK-254_AE-6410-11A_1x11_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-11A example for new part number: 22-27-2111, 11 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +11 +11 +Connector_Molex +Molex_KK-254_AE-6410-12A_1x12_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-12A example for new part number: 22-27-2121, 12 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +12 +12 +Connector_Molex +Molex_KK-254_AE-6410-13A_1x13_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-13A example for new part number: 22-27-2131, 13 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +13 +13 +Connector_Molex +Molex_KK-254_AE-6410-14A_1x14_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-14A example for new part number: 22-27-2141, 14 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +14 +14 +Connector_Molex +Molex_KK-254_AE-6410-15A_1x15_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-15A example for new part number: 22-27-2151, 15 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +15 +15 +Connector_Molex +Molex_KK-254_AE-6410-16A_1x16_P2.54mm_Vertical +Molex KK-254 Interconnect System, old/engineering part number: AE-6410-16A example for new part number: 22-27-2161, 16 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-254 vertical +0 +16 +16 +Connector_Molex +Molex_KK-396_A-41791-0002_1x02_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0002 example for new part number: 26-60-4020, 2 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +2 +2 +Connector_Molex +Molex_KK-396_A-41791-0003_1x03_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0003 example for new part number: 26-60-4030, 3 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +3 +3 +Connector_Molex +Molex_KK-396_A-41791-0004_1x04_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0004 example for new part number: 26-60-4040, 4 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +4 +4 +Connector_Molex +Molex_KK-396_A-41791-0005_1x05_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0005 example for new part number: 26-60-4050, 5 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +5 +5 +Connector_Molex +Molex_KK-396_A-41791-0006_1x06_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0006 example for new part number: 26-60-4060, 6 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +6 +6 +Connector_Molex +Molex_KK-396_A-41791-0007_1x07_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0007 example for new part number: 26-60-4070, 7 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +7 +7 +Connector_Molex +Molex_KK-396_A-41791-0008_1x08_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0008 example for new part number: 26-60-4080, 8 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +8 +8 +Connector_Molex +Molex_KK-396_A-41791-0009_1x09_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0009 example for new part number: 26-60-4090, 9 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +9 +9 +Connector_Molex +Molex_KK-396_A-41791-0010_1x10_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0010 example for new part number: 26-60-4100, 10 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +10 +10 +Connector_Molex +Molex_KK-396_A-41791-0011_1x11_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0011 example for new part number: 26-60-4110, 11 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +11 +11 +Connector_Molex +Molex_KK-396_A-41791-0012_1x12_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0012 example for new part number: 26-60-4120, 12 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +12 +12 +Connector_Molex +Molex_KK-396_A-41791-0013_1x13_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0013 example for new part number: 26-60-4130, 13 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +13 +13 +Connector_Molex +Molex_KK-396_A-41791-0014_1x14_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0014 example for new part number: 26-60-4140, 14 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +14 +14 +Connector_Molex +Molex_KK-396_A-41791-0015_1x15_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0015 example for new part number: 26-60-4150, 15 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +15 +15 +Connector_Molex +Molex_KK-396_A-41791-0016_1x16_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0016 example for new part number: 26-60-4160, 16 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +16 +16 +Connector_Molex +Molex_KK-396_A-41791-0017_1x17_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0017 example for new part number: 26-60-4170, 17 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +17 +17 +Connector_Molex +Molex_KK-396_A-41791-0018_1x18_P3.96mm_Vertical +Molex KK 396 Interconnect System, old/engineering part number: A-41791-0018 example for new part number: 26-60-4180, 18 Pins (https://www.molex.com/pdm_docs/sd/026604020_sd.pdf), generated with kicad-footprint-generator +connector Molex KK-396 vertical +0 +18 +18 +Connector_Molex +Molex_Mega-Fit_76825-0002_2x01_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0002 (compatible alternatives: 172064-0002, 172064-1002), 1 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +2 +2 +Connector_Molex +Molex_Mega-Fit_76825-0004_2x02_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0004 (compatible alternatives: 172064-0004, 172064-1004), 2 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +4 +4 +Connector_Molex +Molex_Mega-Fit_76825-0006_2x03_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0006 (compatible alternatives: 172064-0006, 172064-1006), 3 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +6 +6 +Connector_Molex +Molex_Mega-Fit_76825-0008_2x04_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0008 (compatible alternatives: 172064-0008, 172064-1008), 4 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +8 +8 +Connector_Molex +Molex_Mega-Fit_76825-0010_2x05_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0010 (compatible alternatives: 172064-0010, 172064-1010), 5 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +10 +10 +Connector_Molex +Molex_Mega-Fit_76825-0012_2x06_P5.70mm_Horizontal +Molex Mega-Fit Power Connectors, 76825-0012 (compatible alternatives: 172064-0012, 172064-1012), 6 Pins per row (http://www.molex.com/pdm_docs/sd/1720640002_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit top entry +0 +12 +12 +Connector_Molex +Molex_Mega-Fit_76829-0002_2x01_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0002 (compatible alternatives: 172065-0002, 172065-1002), 1 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +2 +2 +Connector_Molex +Molex_Mega-Fit_76829-0004_2x02_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0004 (compatible alternatives: 172065-0004, 172065-1004), 2 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Mega-Fit_76829-0006_2x03_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0006 (compatible alternatives: 172065-0006, 172065-1006), 3 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Mega-Fit_76829-0008_2x04_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0008 (compatible alternatives: 172065-0008, 172065-1008), 4 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Mega-Fit_76829-0010_2x05_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0010 (compatible alternatives: 172065-0010, 172065-1010), 5 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +10 +10 +Connector_Molex +Molex_Mega-Fit_76829-0012_2x06_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0012 (compatible alternatives: 172065-0012, 172065-1012), 6 Pins per row (http://www.molex.com/pdm_docs/sd/768290004_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +12 +12 +Connector_Molex +Molex_Mega-Fit_76829-0102_2x01_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0102 (compatible alternatives: 172065-0202, 172065-0302), 1 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +2 +2 +Connector_Molex +Molex_Mega-Fit_76829-0104_2x02_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0104 (compatible alternatives: 172065-0204, 172065-0304), 2 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Mega-Fit_76829-0106_2x03_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0106 (compatible alternatives: 172065-0206, 172065-0306), 3 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Mega-Fit_76829-0108_2x04_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0108 (compatible alternatives: 172065-0208, 172065-0308), 4 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Mega-Fit_76829-0110_2x05_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0110 (compatible alternatives: 172065-0210, 172065-0310), 5 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +10 +10 +Connector_Molex +Molex_Mega-Fit_76829-0112_2x06_P5.70mm_Vertical +Molex Mega-Fit Power Connectors, 76829-0112 (compatible alternatives: 172065-0212, 172065-0312), 6 Pins per row (http://www.molex.com/pdm_docs/sd/768290102_sd.pdf), generated with kicad-footprint-generator +connector Molex Mega-Fit side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0200_2x01_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0200 (alternative finishes: 43045-020x), 1 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0210_2x01-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0210 (compatible alternatives: 43045-0211, 43045-0209), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +4 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0212_2x01_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0212 (compatible alternatives: 43045-0213, 43045-0224), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0215_2x01_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0215 (compatible alternatives: 43045-0216, 43045-0217), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0218_2x01-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0218 (compatible alternatives: 43045-0219, 43045-0220), 1 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +4 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0221_2x01-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0221 (alternative finishes: 43045-022x), 1 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +4 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0400_2x02_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0400 (alternative finishes: 43045-040x), 2 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0410_2x02-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0410 (compatible alternatives: 43045-0411, 43045-0409), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +6 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0412_2x02_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0412 (compatible alternatives: 43045-0413, 43045-0424), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0415_2x02_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0415 (compatible alternatives: 43045-0416, 43045-0417), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0418_2x02-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0418 (compatible alternatives: 43045-0419, 43045-0420), 2 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +6 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0421_2x02-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0421 (alternative finishes: 43045-042x), 2 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +6 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0600_2x03_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0600 (alternative finishes: 43045-060x), 3 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0610_2x03-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0610 (compatible alternatives: 43045-0611, 43045-0609), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +8 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0612_2x03_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0612 (compatible alternatives: 43045-0613, 43045-0624), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0615_2x03_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0615 (compatible alternatives: 43045-0616, 43045-0617), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0618_2x03-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0618 (compatible alternatives: 43045-0619, 43045-0620), 3 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +8 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0621_2x03-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0621 (alternative finishes: 43045-062x), 3 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +8 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0800_2x04_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0800 (alternative finishes: 43045-080x), 4 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0810_2x04-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0810 (compatible alternatives: 43045-0811, 43045-0809), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +10 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0812_2x04_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0812 (compatible alternatives: 43045-0813, 43045-0824), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0815_2x04_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0815 (compatible alternatives: 43045-0816, 43045-0817), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0818_2x04-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-0818 (compatible alternatives: 43045-0819, 43045-0820), 4 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +10 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43045-0821_2x04-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-0821 (alternative finishes: 43045-082x), 4 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +10 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1000_2x05_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1000 (alternative finishes: 43045-100x), 5 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1010_2x05-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1010 (compatible alternatives: 43045-1011, 43045-1009), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +12 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1012_2x05_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1012 (compatible alternatives: 43045-1013, 43045-1024), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1015_2x05_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1015 (compatible alternatives: 43045-1016, 43045-1017), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1018_2x05-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1018 (compatible alternatives: 43045-1019, 43045-1020), 5 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +12 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1021_2x05-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1021 (alternative finishes: 43045-102x), 5 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +12 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1200_2x06_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1200 (alternative finishes: 43045-120x), 6 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1210_2x06-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1210 (compatible alternatives: 43045-1211, 43045-1209), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +14 +13 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1212_2x06_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1212 (compatible alternatives: 43045-1213, 43045-1224), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1215_2x06_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1215 (compatible alternatives: 43045-1216, 43045-1217), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1218_2x06-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1218 (compatible alternatives: 43045-1219, 43045-1220), 6 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +14 +13 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1221_2x06-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1221 (alternative finishes: 43045-122x), 6 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +14 +13 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1400_2x07_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1400 (alternative finishes: 43045-140x), 7 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +14 +14 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1410_2x07-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1410 (compatible alternatives: 43045-1411, 43045-1409), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +16 +15 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1412_2x07_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1412 (compatible alternatives: 43045-1413, 43045-1424), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +14 +14 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1415_2x07_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1415 (compatible alternatives: 43045-1416, 43045-1417), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +14 +14 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1418_2x07-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1418 (compatible alternatives: 43045-1419, 43045-1420), 7 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +16 +15 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1421_2x07-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1421 (alternative finishes: 43045-142x), 7 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +16 +15 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1600_2x08_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1600 (alternative finishes: 43045-160x), 8 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +16 +16 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1610_2x08-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1610 (compatible alternatives: 43045-1611, 43045-1609), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +18 +17 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1612_2x08_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1612 (compatible alternatives: 43045-1613, 43045-1624), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +16 +16 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1615_2x08_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1615 (compatible alternatives: 43045-1616, 43045-1617), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +16 +16 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1618_2x08-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1618 (compatible alternatives: 43045-1619, 43045-1620), 8 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +18 +17 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1621_2x08-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1621 (alternative finishes: 43045-162x), 8 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +18 +17 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1800_2x09_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1800 (alternative finishes: 43045-180x), 9 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +18 +18 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1810_2x09-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1810 (compatible alternatives: 43045-1811, 43045-1809), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +20 +19 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1812_2x09_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1812 (compatible alternatives: 43045-1813, 43045-1824), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +18 +18 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1815_2x09_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1815 (compatible alternatives: 43045-1816, 43045-1817), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +18 +18 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1818_2x09-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-1818 (compatible alternatives: 43045-1819, 43045-1820), 9 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +20 +19 +Connector_Molex +Molex_Micro-Fit_3.0_43045-1821_2x09-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-1821 (alternative finishes: 43045-182x), 9 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +20 +19 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2000_2x10_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2000 (alternative finishes: 43045-200x), 10 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +20 +20 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2010_2x10-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2010 (compatible alternatives: 43045-2011, 43045-2009), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +22 +21 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2012_2x10_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2012 (compatible alternatives: 43045-2013, 43045-2024), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +20 +20 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2015_2x10_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2015 (compatible alternatives: 43045-2016, 43045-2017), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +20 +20 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2018_2x10-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2018 (compatible alternatives: 43045-2019, 43045-2020), 10 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +22 +21 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2021_2x10-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2021 (alternative finishes: 43045-202x), 10 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +22 +21 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2200_2x11_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2200 (alternative finishes: 43045-220x), 11 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +22 +22 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2210_2x11-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2210 (compatible alternatives: 43045-2211, 43045-2209), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +24 +23 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2212_2x11_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2212 (compatible alternatives: 43045-2213, 43045-2224), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +22 +22 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2215_2x11_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2215 (compatible alternatives: 43045-2216, 43045-2217), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +22 +22 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2218_2x11-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2218 (compatible alternatives: 43045-2219, 43045-2220), 11 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +24 +23 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2221_2x11-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2221 (alternative finishes: 43045-222x), 11 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +24 +23 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2400_2x12_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2400 (alternative finishes: 43045-240x), 12 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +24 +24 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2410_2x12-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2410 (compatible alternatives: 43045-2411, 43045-2409), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450210_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +26 +25 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2412_2x12_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2412 (compatible alternatives: 43045-2413, 43045-2424), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450212_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +24 +24 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2415_2x12_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2415 (compatible alternatives: 43045-2416, 43045-2417), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450217_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +24 +24 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2418_2x12-1MP_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43045-2418 (compatible alternatives: 43045-2419, 43045-2420), 12 Pins per row (http://www.molex.com/pdm_docs/sd/430450218_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 side entry +0 +26 +25 +Connector_Molex +Molex_Micro-Fit_3.0_43045-2421_2x12-1MP_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43045-2421 (alternative finishes: 43045-242x), 12 Pins per row (https://www.molex.com/pdm_docs/sd/430450221_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 horizontal +0 +26 +25 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0200_1x02_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0200 (compatible alternatives: 43650-0201, 43650-0202), 2 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0215_1x02_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0215 (compatible alternatives: 43650-0216, 43650-0217), 2 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +2 +2 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0300_1x03_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0300 (compatible alternatives: 43650-0301, 43650-0302), 3 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +3 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0315_1x03_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0315 (compatible alternatives: 43650-0316, 43650-0317), 3 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +3 +3 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0400_1x04_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0400 (compatible alternatives: 43650-0401, 43650-0402), 4 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0415_1x04_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0415 (compatible alternatives: 43650-0416, 43650-0417), 4 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +4 +4 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0500_1x05_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0500 (compatible alternatives: 43650-0501, 43650-0502), 5 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +5 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0515_1x05_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0515 (compatible alternatives: 43650-0516, 43650-0517), 5 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +5 +5 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0600_1x06_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0600 (compatible alternatives: 43650-0601, 43650-0602), 6 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0615_1x06_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0615 (compatible alternatives: 43650-0616, 43650-0617), 6 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +6 +6 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0700_1x07_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0700 (compatible alternatives: 43650-0701, 43650-0702), 7 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +7 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0715_1x07_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0715 (compatible alternatives: 43650-0716, 43650-0717), 7 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +7 +7 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0800_1x08_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0800 (compatible alternatives: 43650-0801, 43650-0802), 8 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0815_1x08_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0815 (compatible alternatives: 43650-0816, 43650-0817), 8 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +8 +8 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0900_1x09_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-0900 (compatible alternatives: 43650-0901, 43650-0902), 9 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +9 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43650-0915_1x09_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-0915 (compatible alternatives: 43650-0916, 43650-0917), 9 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +9 +9 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1000_1x10_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-1000 (compatible alternatives: 43650-1001, 43650-1002), 10 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1015_1x10_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-1015 (compatible alternatives: 43650-1016, 43650-1017), 10 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +10 +10 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1100_1x11_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-1100 (compatible alternatives: 43650-1101, 43650-1102), 11 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +11 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1115_1x11_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-1115 (compatible alternatives: 43650-1116, 43650-1117), 11 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +11 +11 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1200_1x12_P3.00mm_Horizontal +Molex Micro-Fit 3.0 Connector System, 43650-1200 (compatible alternatives: 43650-1201, 43650-1202), 12 Pins per row (https://www.molex.com/pdm_docs/sd/436500300_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 top entry +0 +12 +12 +Connector_Molex +Molex_Micro-Fit_3.0_43650-1215_1x12_P3.00mm_Vertical +Molex Micro-Fit 3.0 Connector System, 43650-1215 (compatible alternatives: 43650-1216, 43650-1217), 12 Pins per row (http://www.molex.com/pdm_docs/sd/436500215_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Fit_3.0 vertical +0 +12 +12 +Connector_Molex +Molex_Micro-Latch_53253-0270_1x02_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0270 (compatible alternatives: 53253-0250), 2 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +2 +2 +Connector_Molex +Molex_Micro-Latch_53253-0370_1x03_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0370 (compatible alternatives: 53253-0350), 3 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +3 +3 +Connector_Molex +Molex_Micro-Latch_53253-0470_1x04_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0470 (compatible alternatives: 53253-0450), 4 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +4 +4 +Connector_Molex +Molex_Micro-Latch_53253-0570_1x05_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0570 (compatible alternatives: 53253-0550), 5 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +5 +5 +Connector_Molex +Molex_Micro-Latch_53253-0670_1x06_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0670 (compatible alternatives: 53253-0650), 6 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +6 +6 +Connector_Molex +Molex_Micro-Latch_53253-0770_1x07_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0770 (compatible alternatives: 53253-0750), 7 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +7 +7 +Connector_Molex +Molex_Micro-Latch_53253-0870_1x08_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0870 (compatible alternatives: 53253-0850), 8 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +8 +8 +Connector_Molex +Molex_Micro-Latch_53253-0970_1x09_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-0970 (compatible alternatives: 53253-0950), 9 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +9 +9 +Connector_Molex +Molex_Micro-Latch_53253-1070_1x10_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1070 (compatible alternatives: 53253-1050), 10 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +10 +10 +Connector_Molex +Molex_Micro-Latch_53253-1170_1x11_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1170 (compatible alternatives: 53253-1150), 11 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +11 +11 +Connector_Molex +Molex_Micro-Latch_53253-1270_1x12_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1270 (compatible alternatives: 53253-1250), 12 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +12 +12 +Connector_Molex +Molex_Micro-Latch_53253-1370_1x13_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1370 (compatible alternatives: 53253-1350), 13 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +13 +13 +Connector_Molex +Molex_Micro-Latch_53253-1470_1x14_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1470 (compatible alternatives: 53253-1450), 14 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +14 +14 +Connector_Molex +Molex_Micro-Latch_53253-1570_1x15_P2.00mm_Vertical +Molex Micro-Latch Wire-to-Board Connector System, 53253-1570 (compatible alternatives: 53253-1550), 15 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch side entry +0 +15 +15 +Connector_Molex +Molex_Micro-Latch_53254-0270_1x02_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0270 (compatible alternatives: 53254-0250), 2 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +2 +2 +Connector_Molex +Molex_Micro-Latch_53254-0370_1x03_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0370 (compatible alternatives: 53254-0350), 3 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +3 +3 +Connector_Molex +Molex_Micro-Latch_53254-0470_1x04_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0470 (compatible alternatives: 53254-0450), 4 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +4 +4 +Connector_Molex +Molex_Micro-Latch_53254-0570_1x05_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0570 (compatible alternatives: 53254-0550), 5 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +5 +5 +Connector_Molex +Molex_Micro-Latch_53254-0670_1x06_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0670 (compatible alternatives: 53254-0650), 6 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +6 +6 +Connector_Molex +Molex_Micro-Latch_53254-0770_1x07_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0770 (compatible alternatives: 53254-0750), 7 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +7 +7 +Connector_Molex +Molex_Micro-Latch_53254-0870_1x08_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0870 (compatible alternatives: 53254-0850), 8 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +8 +8 +Connector_Molex +Molex_Micro-Latch_53254-0970_1x09_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-0970 (compatible alternatives: 53254-0950), 9 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +9 +9 +Connector_Molex +Molex_Micro-Latch_53254-1070_1x10_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1070 (compatible alternatives: 53254-1050), 10 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +10 +10 +Connector_Molex +Molex_Micro-Latch_53254-1170_1x11_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1170 (compatible alternatives: 53254-1150), 11 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +11 +11 +Connector_Molex +Molex_Micro-Latch_53254-1270_1x12_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1270 (compatible alternatives: 53254-1250), 12 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +12 +12 +Connector_Molex +Molex_Micro-Latch_53254-1370_1x13_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1370 (compatible alternatives: 53254-1350), 13 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +13 +13 +Connector_Molex +Molex_Micro-Latch_53254-1470_1x14_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1470 (compatible alternatives: 53254-1450), 14 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +14 +14 +Connector_Molex +Molex_Micro-Latch_53254-1570_1x15_P2.00mm_Horizontal +Molex Micro-Latch Wire-to-Board Connector System, 53254-1570 (compatible alternatives: 53254-1550), 15 Pins per row (http://www.molex.com/pdm_docs/sd/532530770_sd.pdf), generated with kicad-footprint-generator +connector Molex Micro-Latch top entry +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55932-0210_1x02_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0210, with PCB locator, 2 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55932-0230_1x02_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0230, 2 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55932-0310_1x03_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0310, with PCB locator, 3 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55932-0330_1x03_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0330, 3 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55932-0410_1x04_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0410, with PCB locator, 4 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55932-0430_1x04_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0430, 4 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55932-0510_1x05_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0510, with PCB locator, 5 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55932-0530_1x05_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0530, 5 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55932-0610_1x06_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0610, with PCB locator, 6 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55932-0630_1x06_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0630, 6 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55932-0710_1x07_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0710, with PCB locator, 7 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55932-0730_1x07_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0730, 7 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55932-0810_1x08_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0810, with PCB locator, 8 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55932-0830_1x08_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0830, 8 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55932-0910_1x09_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0910, with PCB locator, 9 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55932-0930_1x09_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-0930, 9 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55932-1010_1x10_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1010, with PCB locator, 10 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55932-1030_1x10_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1030, 10 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55932-1110_1x11_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1110, with PCB locator, 11 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55932-1130_1x11_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1130, 11 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55932-1210_1x12_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1210, with PCB locator, 12 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55932-1230_1x12_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1230, 12 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55932-1310_1x13_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1310, with PCB locator, 13 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55932-1330_1x13_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1330, 13 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55932-1410_1x14_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1410, with PCB locator, 14 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55932-1430_1x14_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1430, 14 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55932-1510_1x15_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1510, with PCB locator, 15 Pins (http://www.molex.com/pdm_docs/sd/559320210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55932-1530_1x15_P2.00mm_Vertical +Molex MicroClasp Wire-to-Board System, 55932-1530, 15 Pins (http://www.molex.com/pdm_docs/sd/559320530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp side entry +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55935-0210_1x02_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0210, with PCB locator, 2 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55935-0230_1x02_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0230, 2 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +2 +2 +Connector_Molex +Molex_MicroClasp_55935-0310_1x03_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0310, with PCB locator, 3 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55935-0330_1x03_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0330, 3 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +3 +3 +Connector_Molex +Molex_MicroClasp_55935-0410_1x04_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0410, with PCB locator, 4 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55935-0430_1x04_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0430, 4 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +4 +4 +Connector_Molex +Molex_MicroClasp_55935-0510_1x05_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0510, with PCB locator, 5 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55935-0530_1x05_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0530, 5 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +5 +5 +Connector_Molex +Molex_MicroClasp_55935-0610_1x06_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0610, with PCB locator, 6 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55935-0630_1x06_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0630, 6 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +6 +6 +Connector_Molex +Molex_MicroClasp_55935-0710_1x07_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0710, with PCB locator, 7 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55935-0730_1x07_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0730, 7 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +7 +7 +Connector_Molex +Molex_MicroClasp_55935-0810_1x08_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0810, with PCB locator, 8 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55935-0830_1x08_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0830, 8 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +8 +8 +Connector_Molex +Molex_MicroClasp_55935-0910_1x09_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0910, with PCB locator, 9 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55935-0930_1x09_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-0930, 9 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +9 +9 +Connector_Molex +Molex_MicroClasp_55935-1010_1x10_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1010, with PCB locator, 10 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55935-1030_1x10_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1030, 10 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +10 +10 +Connector_Molex +Molex_MicroClasp_55935-1110_1x11_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1110, with PCB locator, 11 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55935-1130_1x11_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1130, 11 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +11 +11 +Connector_Molex +Molex_MicroClasp_55935-1210_1x12_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1210, with PCB locator, 12 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55935-1230_1x12_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1230, 12 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +12 +12 +Connector_Molex +Molex_MicroClasp_55935-1310_1x13_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1310, with PCB locator, 13 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55935-1330_1x13_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1330, 13 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +13 +13 +Connector_Molex +Molex_MicroClasp_55935-1410_1x14_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1410, with PCB locator, 14 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55935-1430_1x14_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1430, 14 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +14 +14 +Connector_Molex +Molex_MicroClasp_55935-1510_1x15_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1510, with PCB locator, 15 Pins (http://www.molex.com/pdm_docs/sd/559350210_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +15 +15 +Connector_Molex +Molex_MicroClasp_55935-1530_1x15_P2.00mm_Horizontal +Molex MicroClasp Wire-to-Board System, 55935-1530, 15 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator +connector Molex MicroClasp horizontal +0 +15 +15 +Connector_Molex +Molex_Mini-Fit_Jr_5566-02A2_2x01_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-02A2, example for new mpn: 39-28-902x, 1 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5566-02A_2x01_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-02A, example for new mpn: 39-28-x02x, 1 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5566-04A2_2x02_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-04A2, example for new mpn: 39-28-904x, 2 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5566-04A_2x02_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-04A, example for new mpn: 39-28-x04x, 2 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5566-06A2_2x03_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-06A2, example for new mpn: 39-28-906x, 3 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5566-06A_2x03_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-06A, example for new mpn: 39-28-x06x, 3 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5566-08A2_2x04_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-08A2, example for new mpn: 39-28-908x, 4 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5566-08A_2x04_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-08A, example for new mpn: 39-28-x08x, 4 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5566-10A2_2x05_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-10A2, example for new mpn: 39-28-910x, 5 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5566-10A_2x05_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-10A, example for new mpn: 39-28-x10x, 5 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5566-12A2_2x06_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-12A2, example for new mpn: 39-28-912x, 6 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5566-12A_2x06_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-12A, example for new mpn: 39-28-x12x, 6 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5566-14A2_2x07_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-14A2, example for new mpn: 39-28-914x, 7 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5566-14A_2x07_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-14A, example for new mpn: 39-28-x14x, 7 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5566-16A2_2x08_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-16A2, example for new mpn: 39-28-916x, 8 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5566-16A_2x08_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-16A, example for new mpn: 39-28-x16x, 8 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5566-18A2_2x09_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-18A2, example for new mpn: 39-28-918x, 9 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5566-18A_2x09_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-18A, example for new mpn: 39-28-x18x, 9 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5566-20A2_2x10_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-20A2, example for new mpn: 39-28-920x, 10 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5566-20A_2x10_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-20A, example for new mpn: 39-28-x20x, 10 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5566-22A2_2x11_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-22A2, example for new mpn: 39-28-922x, 11 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5566-22A_2x11_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-22A, example for new mpn: 39-28-x22x, 11 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5566-24A2_2x12_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-24A2, example for new mpn: 39-28-924x, 12 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039289068_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entryplastic_peg +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Jr_5566-24A_2x12_P4.20mm_Vertical +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-24A, example for new mpn: 39-28-x24x, 12 Pins per row, Mounting: (http://www.molex.com/pdm_docs/sd/039281043_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr side entry +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Jr_5569-02A1_2x01_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-02A1, example for new mpn: 39-29-4029, 1 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5569-02A2_2x01_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-02A2, example for new mpn: 39-30-0020, 1 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +2 +2 +Connector_Molex +Molex_Mini-Fit_Jr_5569-04A1_2x02_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-04A1, example for new mpn: 39-29-4049, 2 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5569-04A2_2x02_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-04A2, example for new mpn: 39-30-0040, 2 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +4 +4 +Connector_Molex +Molex_Mini-Fit_Jr_5569-06A1_2x03_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-06A1, example for new mpn: 39-29-4069, 3 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5569-06A2_2x03_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-06A2, example for new mpn: 39-30-0060, 3 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +6 +6 +Connector_Molex +Molex_Mini-Fit_Jr_5569-08A1_2x04_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-08A1, example for new mpn: 39-29-4089, 4 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5569-08A2_2x04_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-08A2, example for new mpn: 39-30-0080, 4 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +8 +8 +Connector_Molex +Molex_Mini-Fit_Jr_5569-10A1_2x05_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-10A1, example for new mpn: 39-29-4109, 5 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5569-10A2_2x05_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-10A2, example for new mpn: 39-30-0100, 5 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +10 +10 +Connector_Molex +Molex_Mini-Fit_Jr_5569-12A1_2x06_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-12A1, example for new mpn: 39-29-4129, 6 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5569-12A2_2x06_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-12A2, example for new mpn: 39-30-0120, 6 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +12 +12 +Connector_Molex +Molex_Mini-Fit_Jr_5569-14A1_2x07_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-14A1, example for new mpn: 39-29-4149, 7 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5569-14A2_2x07_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-14A2, example for new mpn: 39-30-0140, 7 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +14 +14 +Connector_Molex +Molex_Mini-Fit_Jr_5569-16A1_2x08_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-16A1, example for new mpn: 39-29-4169, 8 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5569-16A2_2x08_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-16A2, example for new mpn: 39-30-0160, 8 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +16 +16 +Connector_Molex +Molex_Mini-Fit_Jr_5569-18A1_2x09_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-18A1, example for new mpn: 39-29-4189, 9 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5569-18A2_2x09_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-18A2, example for new mpn: 39-30-0180, 9 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +18 +18 +Connector_Molex +Molex_Mini-Fit_Jr_5569-20A1_2x10_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-20A1, example for new mpn: 39-29-4209, 10 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5569-20A2_2x10_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-20A2, example for new mpn: 39-30-0200, 10 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +20 +20 +Connector_Molex +Molex_Mini-Fit_Jr_5569-22A1_2x11_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-22A1, example for new mpn: 39-29-4229, 11 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5569-22A2_2x11_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-22A2, example for new mpn: 39-30-0220, 11 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +22 +22 +Connector_Molex +Molex_Mini-Fit_Jr_5569-24A1_2x12_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-24A1, example for new mpn: 39-29-4249, 12 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryscrew_flange +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Jr_5569-24A2_2x12_P4.20mm_Horizontal +Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5569-24A2, example for new mpn: 39-30-0240, 12 Pins per row, Mounting: Snap-in Plastic Peg PCB Lock (http://www.molex.com/pdm_docs/sd/039300020_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Jr top entryplastic_peg +0 +24 +24 +Connector_Molex +Molex_Mini-Fit_Sr_42819-22XX_1x02_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-22XX, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +6 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42819-22XX_1x02_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-22XX, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +32 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42819-32XX_1x03_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-32XX, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +8 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42819-32XX_1x03_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-32XX, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +47 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42819-42XX_1x04_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-42XX, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +10 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42819-42XX_1x04_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-42XX, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +62 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42819-52XX_1x05_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-52XX, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +12 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42819-52XX_1x05_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-52XX, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +77 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42819-62XX_1x06_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 42819-62XX, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +14 +6 +Connector_Molex +Molex_Mini-Fit_Sr_42819-62XX_1x06_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42819-62XX, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +92 +6 +Connector_Molex +Molex_Mini-Fit_Sr_42820-22XX_1x02_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-22XX, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +6 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42820-22XX_1x02_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-22XX, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +32 +2 +Connector_Molex +Molex_Mini-Fit_Sr_42820-32XX_1x03_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-32XX, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +8 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42820-32XX_1x03_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-32XX, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +47 +3 +Connector_Molex +Molex_Mini-Fit_Sr_42820-42XX_1x04_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-42XX, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +10 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42820-42XX_1x04_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-42XX, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +62 +4 +Connector_Molex +Molex_Mini-Fit_Sr_42820-52XX_1x05_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-52XX, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +12 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42820-52XX_1x05_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-52XX, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +77 +5 +Connector_Molex +Molex_Mini-Fit_Sr_42820-62XX_1x06_P10.00mm_Horizontal +Molex Mini-Fit Sr. Power Connectors, 42820-62XX, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +14 +6 +Connector_Molex +Molex_Mini-Fit_Sr_42820-62XX_1x06_P10.00mm_Horizontal_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 42820-62XX, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/428202214_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr top entry +0 +92 +6 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx06_2x03_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx06, 3 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +14 +6 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx06_2x03_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx06, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +92 +6 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx08_2x04_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx08, 4 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +18 +8 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx08_2x04_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx08, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +122 +8 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx10_2x05_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx10, 5 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +22 +10 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx10_2x05_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx10, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +152 +10 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx12_2x06_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx12, 6 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +26 +12 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx12_2x06_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx12, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +182 +12 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx14_2x07_P10.00mm_Vertical +Molex Mini-Fit Sr. Power Connectors, 43915-xx14, 7 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +30 +14 +Connector_Molex +Molex_Mini-Fit_Sr_43915-xx14_2x07_P10.00mm_Vertical_ThermalVias +Molex Mini-Fit Sr. Power Connectors, 43915-xx14, With thermal vias in pads, 7 Pins per row (http://www.molex.com/pdm_docs/sd/439151404_sd.pdf), generated with kicad-footprint-generator +connector Molex Mini-Fit_Sr side entry +0 +212 +14 +Connector_Molex +Molex_Nano-Fit_105309-xx02_1x02_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx02, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +2 +2 +Connector_Molex +Molex_Nano-Fit_105309-xx03_1x03_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx03, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +3 +3 +Connector_Molex +Molex_Nano-Fit_105309-xx04_1x04_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx04, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105309-xx05_1x05_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx05, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +5 +5 +Connector_Molex +Molex_Nano-Fit_105309-xx06_1x06_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx06, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105309-xx07_1x07_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx07, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +7 +7 +Connector_Molex +Molex_Nano-Fit_105309-xx08_1x08_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105309-xx08, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053091203_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105310-xx04_2x02_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx04, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105310-xx06_2x03_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx06, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105310-xx08_2x04_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx08, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105310-xx10_2x05_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx10, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +10 +10 +Connector_Molex +Molex_Nano-Fit_105310-xx12_2x06_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx12, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +12 +12 +Connector_Molex +Molex_Nano-Fit_105310-xx14_2x07_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx14, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +14 +14 +Connector_Molex +Molex_Nano-Fit_105310-xx16_2x08_P2.50mm_Vertical +Molex Nano-Fit Power Connectors, 105310-xx16, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053101208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit side entry +0 +16 +16 +Connector_Molex +Molex_Nano-Fit_105313-xx02_1x02_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx02, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +2 +2 +Connector_Molex +Molex_Nano-Fit_105313-xx03_1x03_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx03, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +3 +3 +Connector_Molex +Molex_Nano-Fit_105313-xx04_1x04_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx04, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105313-xx05_1x05_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx05, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +5 +5 +Connector_Molex +Molex_Nano-Fit_105313-xx06_1x06_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx06, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105313-xx07_1x07_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx07, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +7 +7 +Connector_Molex +Molex_Nano-Fit_105313-xx08_1x08_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105313-xx08, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105314-xx04_2x02_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx04, 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +4 +4 +Connector_Molex +Molex_Nano-Fit_105314-xx06_2x03_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx06, 3 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +6 +6 +Connector_Molex +Molex_Nano-Fit_105314-xx08_2x04_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx08, 4 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +8 +8 +Connector_Molex +Molex_Nano-Fit_105314-xx10_2x05_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx10, 5 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +10 +10 +Connector_Molex +Molex_Nano-Fit_105314-xx12_2x06_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx12, 6 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +12 +12 +Connector_Molex +Molex_Nano-Fit_105314-xx14_2x07_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx14, 7 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +14 +14 +Connector_Molex +Molex_Nano-Fit_105314-xx16_2x08_P2.50mm_Horizontal +Molex Nano-Fit Power Connectors, 105314-xx16, 8 Pins per row (http://www.molex.com/pdm_docs/sd/1053141208_sd.pdf), generated with kicad-footprint-generator +connector Molex Nano-Fit top entry +0 +16 +16 +Connector_Molex +Molex_Panelmate_53780-0270_1x02-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0270 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +4 +3 +Connector_Molex +Molex_Panelmate_53780-0370_1x03-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0370 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +5 +4 +Connector_Molex +Molex_Panelmate_53780-0470_1x04-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0470 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +6 +5 +Connector_Molex +Molex_Panelmate_53780-0570_1x05-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0570 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +7 +6 +Connector_Molex +Molex_Panelmate_53780-0670_1x06-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0670 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +8 +7 +Connector_Molex +Molex_Panelmate_53780-0770_1x07-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0770 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +9 +8 +Connector_Molex +Molex_Panelmate_53780-0870_1x08-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0870 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +10 +9 +Connector_Molex +Molex_Panelmate_53780-0970_1x09-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-0970 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +11 +10 +Connector_Molex +Molex_Panelmate_53780-1070_1x10-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1070 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +12 +11 +Connector_Molex +Molex_Panelmate_53780-1270_1x12-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1270 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +14 +13 +Connector_Molex +Molex_Panelmate_53780-1470_1x14-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1470 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +16 +15 +Connector_Molex +Molex_Panelmate_53780-1570_1x15-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1570 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +17 +16 +Connector_Molex +Molex_Panelmate_53780-1870_1x18-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-1870 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +20 +19 +Connector_Molex +Molex_Panelmate_53780-3070_1x30-1MP_P1.25mm_Horizontal +Molex Panelmate series connector, 53780-3070 (), generated with kicad-footprint-generator +connector Molex Panelmate top entry +0 +32 +31 +Connector_Molex +Molex_Pico-Clasp_202396-0207_1x02-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0207 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +4 +3 +Connector_Molex +Molex_Pico-Clasp_202396-0307_1x03-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0307 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +5 +4 +Connector_Molex +Molex_Pico-Clasp_202396-0407_1x04-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0407 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +6 +5 +Connector_Molex +Molex_Pico-Clasp_202396-0507_1x05-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0507 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +7 +6 +Connector_Molex +Molex_Pico-Clasp_202396-0607_1x06-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0607 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +8 +7 +Connector_Molex +Molex_Pico-Clasp_202396-0707_1x07-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0707 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +9 +8 +Connector_Molex +Molex_Pico-Clasp_202396-0807_1x08-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0807 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +10 +9 +Connector_Molex +Molex_Pico-Clasp_202396-0907_1x09-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-0907 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +11 +10 +Connector_Molex +Molex_Pico-Clasp_202396-1007_1x10-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1007 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +12 +11 +Connector_Molex +Molex_Pico-Clasp_202396-1107_1x11-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1107 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +13 +12 +Connector_Molex +Molex_Pico-Clasp_202396-1207_1x12-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1207 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +14 +13 +Connector_Molex +Molex_Pico-Clasp_202396-1307_1x13-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1307 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +15 +14 +Connector_Molex +Molex_Pico-Clasp_202396-1407_1x14-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1407 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +16 +15 +Connector_Molex +Molex_Pico-Clasp_202396-1507_1x15-1MP_P1.00mm_Horizontal +Molex Pico-Clasp series connector, 202396-1507 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp top entry +0 +17 +16 +Connector_Molex +Molex_Pico-Clasp_501331-0207_1x02-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0207 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +4 +3 +Connector_Molex +Molex_Pico-Clasp_501331-0307_1x03-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0307 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +5 +4 +Connector_Molex +Molex_Pico-Clasp_501331-0407_1x04-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0407 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +6 +5 +Connector_Molex +Molex_Pico-Clasp_501331-0507_1x05-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0507 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +7 +6 +Connector_Molex +Molex_Pico-Clasp_501331-0607_1x06-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0607 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +8 +7 +Connector_Molex +Molex_Pico-Clasp_501331-0707_1x07-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0707 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +9 +8 +Connector_Molex +Molex_Pico-Clasp_501331-0807_1x08-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0807 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +10 +9 +Connector_Molex +Molex_Pico-Clasp_501331-0907_1x09-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-0907 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +11 +10 +Connector_Molex +Molex_Pico-Clasp_501331-1007_1x10-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1007 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +12 +11 +Connector_Molex +Molex_Pico-Clasp_501331-1107_1x11-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1107 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +13 +12 +Connector_Molex +Molex_Pico-Clasp_501331-1207_1x12-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1207 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +14 +13 +Connector_Molex +Molex_Pico-Clasp_501331-1307_1x13-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1307 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +15 +14 +Connector_Molex +Molex_Pico-Clasp_501331-1407_1x14-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1407 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +16 +15 +Connector_Molex +Molex_Pico-Clasp_501331-1507_1x15-1MP_P1.00mm_Vertical +Molex Pico-Clasp series connector, 501331-1507 (http://www.molex.com/pdm_docs/sd/5013310207_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Clasp side entry +0 +17 +16 +Connector_Molex +Molex_Pico-EZmate_78171-0002_1x02-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0002 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +4 +3 +Connector_Molex +Molex_Pico-EZmate_78171-0003_1x03-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0003 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +5 +4 +Connector_Molex +Molex_Pico-EZmate_78171-0004_1x04-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0004 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +6 +5 +Connector_Molex +Molex_Pico-EZmate_78171-0005_1x05-1MP_P1.20mm_Vertical +Molex Pico-EZmate series connector, 78171-0005 (http://www.molex.com/pdm_docs/sd/781710002_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate side entry +0 +7 +6 +Connector_Molex +Molex_Pico-EZmate_Slim_202656-0021_1x02-1MP_P1.20mm_Vertical +Molex Pico-EZmate_Slim series connector, 202656-0021 (http://www.molex.com/pdm_docs/sd/2026560021_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-EZmate_Slim side entry +0 +4 +3 +Connector_Molex +Molex_Pico-Lock_504050-0491_1x04-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0491 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +6 +5 +Connector_Molex +Molex_Pico-Lock_504050-0591_1x05-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0591 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +7 +6 +Connector_Molex +Molex_Pico-Lock_504050-0691_1x06-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0691 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +8 +7 +Connector_Molex +Molex_Pico-Lock_504050-0791_1x07-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0791 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +9 +8 +Connector_Molex +Molex_Pico-Lock_504050-0891_1x08-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-0891 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +10 +9 +Connector_Molex +Molex_Pico-Lock_504050-1091_1x10-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-1091 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +12 +11 +Connector_Molex +Molex_Pico-Lock_504050-1291_1x12-1MP_P1.50mm_Horizontal +Molex Pico-Lock series connector, 504050-1291 (http://www.molex.com/pdm_docs/sd/5040500891_sd.pdf), generated with kicad-footprint-generator +connector Molex Pico-Lock horizontal +0 +14 +13 +Connector_Molex +Molex_Pico-SPOX_87437-1443_1x14-P1.5mm_Vertical +Molex Pico-SPOX Connector System, 87437-1443, 14 Pins per row (https://www.molex.com/pdm_docs/sd/874371443_sd.pdf#page=2) +molex pico spox 14 +0 +28 +14 +Connector_Molex +Molex_PicoBlade_53047-0210_1x02_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0210, 2 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +2 +2 +Connector_Molex +Molex_PicoBlade_53047-0310_1x03_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0310, 3 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +3 +3 +Connector_Molex +Molex_PicoBlade_53047-0410_1x04_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0410, 4 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +4 +4 +Connector_Molex +Molex_PicoBlade_53047-0510_1x05_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0510, 5 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +5 +5 +Connector_Molex +Molex_PicoBlade_53047-0610_1x06_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0610, 6 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +6 +6 +Connector_Molex +Molex_PicoBlade_53047-0710_1x07_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0710, 7 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +7 +7 +Connector_Molex +Molex_PicoBlade_53047-0810_1x08_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0810, 8 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +8 +8 +Connector_Molex +Molex_PicoBlade_53047-0910_1x09_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-0910, 9 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +9 +9 +Connector_Molex +Molex_PicoBlade_53047-1010_1x10_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1010, 10 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +10 +10 +Connector_Molex +Molex_PicoBlade_53047-1110_1x11_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1110, 11 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +11 +11 +Connector_Molex +Molex_PicoBlade_53047-1210_1x12_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1210, 12 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +12 +12 +Connector_Molex +Molex_PicoBlade_53047-1310_1x13_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1310, 13 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +13 +13 +Connector_Molex +Molex_PicoBlade_53047-1410_1x14_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1410, 14 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +14 +14 +Connector_Molex +Molex_PicoBlade_53047-1510_1x15_P1.25mm_Vertical +Molex PicoBlade Connector System, 53047-1510, 15 Pins per row (http://www.molex.com/pdm_docs/sd/530470610_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +15 +15 +Connector_Molex +Molex_PicoBlade_53048-0210_1x02_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0210, 2 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +2 +2 +Connector_Molex +Molex_PicoBlade_53048-0310_1x03_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0310, 3 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +3 +3 +Connector_Molex +Molex_PicoBlade_53048-0410_1x04_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0410, 4 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +4 +4 +Connector_Molex +Molex_PicoBlade_53048-0510_1x05_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0510, 5 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +5 +5 +Connector_Molex +Molex_PicoBlade_53048-0610_1x06_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0610, 6 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +6 +6 +Connector_Molex +Molex_PicoBlade_53048-0710_1x07_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0710, 7 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +7 +7 +Connector_Molex +Molex_PicoBlade_53048-0810_1x08_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0810, 8 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +8 +8 +Connector_Molex +Molex_PicoBlade_53048-0910_1x09_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-0910, 9 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +9 +9 +Connector_Molex +Molex_PicoBlade_53048-1010_1x10_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1010, 10 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +10 +10 +Connector_Molex +Molex_PicoBlade_53048-1110_1x11_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1110, 11 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +11 +11 +Connector_Molex +Molex_PicoBlade_53048-1210_1x12_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1210, 12 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +12 +12 +Connector_Molex +Molex_PicoBlade_53048-1310_1x13_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1310, 13 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +13 +13 +Connector_Molex +Molex_PicoBlade_53048-1410_1x14_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1410, 14 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +14 +14 +Connector_Molex +Molex_PicoBlade_53048-1510_1x15_P1.25mm_Horizontal +Molex PicoBlade Connector System, 53048-1510, 15 Pins per row (http://www.molex.com/pdm_docs/sd/530480210_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +15 +15 +Connector_Molex +Molex_PicoBlade_53261-0271_1x02-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0271 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +4 +3 +Connector_Molex +Molex_PicoBlade_53261-0371_1x03-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0371 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +5 +4 +Connector_Molex +Molex_PicoBlade_53261-0471_1x04-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0471 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +6 +5 +Connector_Molex +Molex_PicoBlade_53261-0571_1x05-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0571 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +7 +6 +Connector_Molex +Molex_PicoBlade_53261-0671_1x06-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0671 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +8 +7 +Connector_Molex +Molex_PicoBlade_53261-0771_1x07-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0771 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +9 +8 +Connector_Molex +Molex_PicoBlade_53261-0871_1x08-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0871 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +10 +9 +Connector_Molex +Molex_PicoBlade_53261-0971_1x09-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-0971 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +11 +10 +Connector_Molex +Molex_PicoBlade_53261-1071_1x10-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1071 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +12 +11 +Connector_Molex +Molex_PicoBlade_53261-1171_1x11-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1171 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +13 +12 +Connector_Molex +Molex_PicoBlade_53261-1271_1x12-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1271 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +14 +13 +Connector_Molex +Molex_PicoBlade_53261-1371_1x13-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1371 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +15 +14 +Connector_Molex +Molex_PicoBlade_53261-1471_1x14-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1471 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +16 +15 +Connector_Molex +Molex_PicoBlade_53261-1571_1x15-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1571 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +17 +16 +Connector_Molex +Molex_PicoBlade_53261-1771_1x17-1MP_P1.25mm_Horizontal +Molex PicoBlade series connector, 53261-1771 (http://www.molex.com/pdm_docs/sd/532610271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade top entry +0 +19 +18 +Connector_Molex +Molex_PicoBlade_53398-0271_1x02-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0271 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +4 +3 +Connector_Molex +Molex_PicoBlade_53398-0371_1x03-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0371 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +5 +4 +Connector_Molex +Molex_PicoBlade_53398-0471_1x04-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0471 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +6 +5 +Connector_Molex +Molex_PicoBlade_53398-0571_1x05-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0571 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +7 +6 +Connector_Molex +Molex_PicoBlade_53398-0671_1x06-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0671 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +8 +7 +Connector_Molex +Molex_PicoBlade_53398-0771_1x07-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0771 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +9 +8 +Connector_Molex +Molex_PicoBlade_53398-0871_1x08-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0871 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +10 +9 +Connector_Molex +Molex_PicoBlade_53398-0971_1x09-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-0971 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +11 +10 +Connector_Molex +Molex_PicoBlade_53398-1071_1x10-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1071 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +12 +11 +Connector_Molex +Molex_PicoBlade_53398-1171_1x11-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1171 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +13 +12 +Connector_Molex +Molex_PicoBlade_53398-1271_1x12-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1271 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +14 +13 +Connector_Molex +Molex_PicoBlade_53398-1371_1x13-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1371 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +15 +14 +Connector_Molex +Molex_PicoBlade_53398-1471_1x14-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1471 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +16 +15 +Connector_Molex +Molex_PicoBlade_53398-1571_1x15-1MP_P1.25mm_Vertical +Molex PicoBlade series connector, 53398-1571 (http://www.molex.com/pdm_docs/sd/533980271_sd.pdf), generated with kicad-footprint-generator +connector Molex PicoBlade side entry +0 +17 +16 +Connector_Molex +Molex_Picoflex_90325-0004_2x02_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0004, 4 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +4 +4 +Connector_Molex +Molex_Picoflex_90325-0006_2x03_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0006, 6 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +6 +6 +Connector_Molex +Molex_Picoflex_90325-0008_2x04_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0008, 8 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +8 +8 +Connector_Molex +Molex_Picoflex_90325-0010_2x05_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0010, 10 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +10 +10 +Connector_Molex +Molex_Picoflex_90325-0012_2x06_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0012, 12 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +12 +12 +Connector_Molex +Molex_Picoflex_90325-0014_2x07_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0014, 14 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +14 +14 +Connector_Molex +Molex_Picoflex_90325-0016_2x08_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0016, 16 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +16 +16 +Connector_Molex +Molex_Picoflex_90325-0018_2x09_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0018, 18 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +18 +18 +Connector_Molex +Molex_Picoflex_90325-0020_2x10_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0020, 20 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +20 +20 +Connector_Molex +Molex_Picoflex_90325-0022_2x11_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0022, 22 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +22 +22 +Connector_Molex +Molex_Picoflex_90325-0024_2x12_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0024, 24 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +24 +24 +Connector_Molex +Molex_Picoflex_90325-0026_2x13_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90325-0026, 26 Pins (http://www.molex.com/pdm_docs/sd/903250004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +26 +26 +Connector_Molex +Molex_Picoflex_90814-0004_2x02_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0004, 4 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +4 +4 +Connector_Molex +Molex_Picoflex_90814-0006_2x03_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0006, 6 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +6 +6 +Connector_Molex +Molex_Picoflex_90814-0008_2x04_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0008, 8 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +8 +8 +Connector_Molex +Molex_Picoflex_90814-0010_2x05_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0010, 10 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +10 +10 +Connector_Molex +Molex_Picoflex_90814-0012_2x06_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0012, 12 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +12 +12 +Connector_Molex +Molex_Picoflex_90814-0014_2x07_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0014, 14 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +14 +14 +Connector_Molex +Molex_Picoflex_90814-0016_2x08_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0016, 16 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +16 +16 +Connector_Molex +Molex_Picoflex_90814-0018_2x09_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0018, 18 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +18 +18 +Connector_Molex +Molex_Picoflex_90814-0020_2x10_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0020, 20 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +20 +20 +Connector_Molex +Molex_Picoflex_90814-0022_2x11_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0022, 22 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +22 +22 +Connector_Molex +Molex_Picoflex_90814-0024_2x12_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0024, 24 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +24 +24 +Connector_Molex +Molex_Picoflex_90814-0026_2x13_P1.27mm_Vertical +Molex Picoflex Ribbon-Cable Connectors, 90814-0026, 26 Pins (http://www.molex.com/pdm_docs/sd/908140004_sd.pdf), generated with kicad-footprint-generator +connector Molex Picoflex side entry +0 +26 +26 +Connector_Molex +Molex_SL_171971-0002_1x02_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0002 (compatible alternatives: 171971-0102, 171971-0202), 2 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +2 +2 +Connector_Molex +Molex_SL_171971-0003_1x03_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0003 (compatible alternatives: 171971-0103, 171971-0203), 3 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +3 +3 +Connector_Molex +Molex_SL_171971-0004_1x04_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0004 (compatible alternatives: 171971-0104, 171971-0204), 4 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +4 +4 +Connector_Molex +Molex_SL_171971-0005_1x05_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0005 (compatible alternatives: 171971-0105, 171971-0205), 5 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +5 +5 +Connector_Molex +Molex_SL_171971-0006_1x06_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0006 (compatible alternatives: 171971-0106, 171971-0206), 6 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +6 +6 +Connector_Molex +Molex_SL_171971-0007_1x07_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0007 (compatible alternatives: 171971-0107, 171971-0207), 7 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +7 +7 +Connector_Molex +Molex_SL_171971-0008_1x08_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0008 (compatible alternatives: 171971-0108, 171971-0208), 8 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +8 +8 +Connector_Molex +Molex_SL_171971-0009_1x09_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0009 (compatible alternatives: 171971-0109, 171971-0209), 9 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +9 +9 +Connector_Molex +Molex_SL_171971-0010_1x10_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0010 (compatible alternatives: 171971-0110, 171971-0210), 10 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +10 +10 +Connector_Molex +Molex_SL_171971-0011_1x11_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0011 (compatible alternatives: 171971-0111, 171971-0211), 11 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +11 +11 +Connector_Molex +Molex_SL_171971-0012_1x12_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0012 (compatible alternatives: 171971-0112, 171971-0212), 12 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +12 +12 +Connector_Molex +Molex_SL_171971-0013_1x13_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0013 (compatible alternatives: 171971-0113, 171971-0213), 13 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +13 +13 +Connector_Molex +Molex_SL_171971-0014_1x14_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0014 (compatible alternatives: 171971-0114, 171971-0214), 14 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +14 +14 +Connector_Molex +Molex_SL_171971-0015_1x15_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0015 (compatible alternatives: 171971-0115, 171971-0215), 15 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +15 +15 +Connector_Molex +Molex_SL_171971-0016_1x16_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0016 (compatible alternatives: 171971-0116, 171971-0216), 16 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +16 +16 +Connector_Molex +Molex_SL_171971-0017_1x17_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0017 (compatible alternatives: 171971-0117, 171971-0217), 17 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +17 +17 +Connector_Molex +Molex_SL_171971-0018_1x18_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0018 (compatible alternatives: 171971-0118, 171971-0218), 18 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +18 +18 +Connector_Molex +Molex_SL_171971-0019_1x19_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0019 (compatible alternatives: 171971-0119, 171971-0219), 19 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +19 +19 +Connector_Molex +Molex_SL_171971-0020_1x20_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0020 (compatible alternatives: 171971-0120, 171971-0220), 20 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +20 +20 +Connector_Molex +Molex_SL_171971-0021_1x21_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0021 (compatible alternatives: 171971-0121, 171971-0221), 21 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +21 +21 +Connector_Molex +Molex_SL_171971-0022_1x22_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0022 (compatible alternatives: 171971-0122, 171971-0222), 22 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +22 +22 +Connector_Molex +Molex_SL_171971-0023_1x23_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0023 (compatible alternatives: 171971-0123, 171971-0223), 23 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +23 +23 +Connector_Molex +Molex_SL_171971-0024_1x24_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0024 (compatible alternatives: 171971-0124, 171971-0224), 24 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +24 +24 +Connector_Molex +Molex_SL_171971-0025_1x25_P2.54mm_Vertical +Molex Stackable Linear Connector, 171971-0025 (compatible alternatives: 171971-0125, 171971-0225), 25 Pins per row (https://www.molex.com/pdm_docs/sd/1719710002_sd.pdf), generated with kicad-footprint-generator +connector Molex SL vertical +0 +25 +25 +Connector_Molex +Molex_SPOX_5267-02A_1x02_P2.50mm_Vertical +Molex SPOX Connector System, 5267-02A, 2 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +2 +2 +Connector_Molex +Molex_SPOX_5267-03A_1x03_P2.50mm_Vertical +Molex SPOX Connector System, 5267-03A, 3 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +3 +3 +Connector_Molex +Molex_SPOX_5267-04A_1x04_P2.50mm_Vertical +Molex SPOX Connector System, 5267-04A, 4 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +4 +4 +Connector_Molex +Molex_SPOX_5267-05A_1x05_P2.50mm_Vertical +Molex SPOX Connector System, 5267-05A, 5 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +5 +5 +Connector_Molex +Molex_SPOX_5267-06A_1x06_P2.50mm_Vertical +Molex SPOX Connector System, 5267-06A, 6 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +6 +6 +Connector_Molex +Molex_SPOX_5267-07A_1x07_P2.50mm_Vertical +Molex SPOX Connector System, 5267-07A, 7 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +7 +7 +Connector_Molex +Molex_SPOX_5267-08A_1x08_P2.50mm_Vertical +Molex SPOX Connector System, 5267-08A, 8 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +8 +8 +Connector_Molex +Molex_SPOX_5267-09A_1x09_P2.50mm_Vertical +Molex SPOX Connector System, 5267-09A, 9 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +9 +9 +Connector_Molex +Molex_SPOX_5267-10A_1x10_P2.50mm_Vertical +Molex SPOX Connector System, 5267-10A, 10 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +10 +10 +Connector_Molex +Molex_SPOX_5267-11A_1x11_P2.50mm_Vertical +Molex SPOX Connector System, 5267-11A, 11 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +11 +11 +Connector_Molex +Molex_SPOX_5267-12A_1x12_P2.50mm_Vertical +Molex SPOX Connector System, 5267-12A, 12 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +12 +12 +Connector_Molex +Molex_SPOX_5267-13A_1x13_P2.50mm_Vertical +Molex SPOX Connector System, 5267-13A, 13 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +13 +13 +Connector_Molex +Molex_SPOX_5267-14A_1x14_P2.50mm_Vertical +Molex SPOX Connector System, 5267-14A, 14 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +14 +14 +Connector_Molex +Molex_SPOX_5267-15A_1x15_P2.50mm_Vertical +Molex SPOX Connector System, 5267-15A, 15 Pins per row (http://www.molex.com/pdm_docs/sd/022035035_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX side entry +0 +15 +15 +Connector_Molex +Molex_SPOX_5268-02A_1x02_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-02A, 2 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +2 +2 +Connector_Molex +Molex_SPOX_5268-03A_1x03_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-03A, 3 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +3 +3 +Connector_Molex +Molex_SPOX_5268-04A_1x04_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-04A, 4 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +4 +4 +Connector_Molex +Molex_SPOX_5268-05A_1x05_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-05A, 5 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +5 +5 +Connector_Molex +Molex_SPOX_5268-06A_1x06_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-06A, 6 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +6 +6 +Connector_Molex +Molex_SPOX_5268-07A_1x07_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-07A, 7 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +7 +7 +Connector_Molex +Molex_SPOX_5268-08A_1x08_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-08A, 8 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +8 +8 +Connector_Molex +Molex_SPOX_5268-09A_1x09_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-09A, 9 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +9 +9 +Connector_Molex +Molex_SPOX_5268-10A_1x10_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-10A, 10 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +10 +10 +Connector_Molex +Molex_SPOX_5268-11A_1x11_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-11A, 11 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +11 +11 +Connector_Molex +Molex_SPOX_5268-12A_1x12_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-12A, 12 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +12 +12 +Connector_Molex +Molex_SPOX_5268-13A_1x13_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-13A, 13 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +13 +13 +Connector_Molex +Molex_SPOX_5268-14A_1x14_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-14A, 14 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +14 +14 +Connector_Molex +Molex_SPOX_5268-15A_1x15_P2.50mm_Horizontal +Molex SPOX Connector System, 5268-15A, 15 Pins per row (https://www.molex.com/pdm_docs/sd/022057045_sd.pdf), generated with kicad-footprint-generator +connector Molex SPOX horizontal +0 +15 +15 +Connector_Molex +Molex_Sabre_43160-0102_1x02_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +4 +2 +Connector_Molex +Molex_Sabre_43160-0102_1x02_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +30 +2 +Connector_Molex +Molex_Sabre_43160-0103_1x03_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +6 +3 +Connector_Molex +Molex_Sabre_43160-0103_1x03_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +45 +3 +Connector_Molex +Molex_Sabre_43160-0104_1x04_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +8 +4 +Connector_Molex +Molex_Sabre_43160-0104_1x04_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +60 +4 +Connector_Molex +Molex_Sabre_43160-0105_1x05_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +10 +5 +Connector_Molex +Molex_Sabre_43160-0105_1x05_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +75 +5 +Connector_Molex +Molex_Sabre_43160-0106_1x06_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-0106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +12 +6 +Connector_Molex +Molex_Sabre_43160-0106_1x06_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-0106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431600105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +90 +6 +Connector_Molex +Molex_Sabre_43160-1102_1x02_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +6 +2 +Connector_Molex +Molex_Sabre_43160-1102_1x02_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +32 +2 +Connector_Molex +Molex_Sabre_43160-1103_1x03_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +8 +3 +Connector_Molex +Molex_Sabre_43160-1103_1x03_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +47 +3 +Connector_Molex +Molex_Sabre_43160-1104_1x04_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +10 +4 +Connector_Molex +Molex_Sabre_43160-1104_1x04_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +62 +4 +Connector_Molex +Molex_Sabre_43160-1105_1x05_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +12 +5 +Connector_Molex +Molex_Sabre_43160-1105_1x05_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +77 +5 +Connector_Molex +Molex_Sabre_43160-1106_1x06_P7.49mm_Horizontal +Molex Sabre Power Connector, 43160-1106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +14 +6 +Connector_Molex +Molex_Sabre_43160-1106_1x06_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 43160-1106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431605304_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +92 +6 +Connector_Molex +Molex_Sabre_43160-2102_1x02_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +6 +2 +Connector_Molex +Molex_Sabre_43160-2102_1x02_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +32 +2 +Connector_Molex +Molex_Sabre_43160-2103_1x03_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +8 +3 +Connector_Molex +Molex_Sabre_43160-2103_1x03_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +47 +3 +Connector_Molex +Molex_Sabre_43160-2104_1x04_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +10 +4 +Connector_Molex +Molex_Sabre_43160-2104_1x04_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +62 +4 +Connector_Molex +Molex_Sabre_43160-2105_1x05_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +12 +5 +Connector_Molex +Molex_Sabre_43160-2105_1x05_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +77 +5 +Connector_Molex +Molex_Sabre_43160-2106_1x06_P7.49mm_Vertical +Molex Sabre Power Connector, 43160-2106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +14 +6 +Connector_Molex +Molex_Sabre_43160-2106_1x06_P7.49mm_Vertical_ThermalVias +Molex Sabre Power Connector, 43160-2106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/431602102_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre side entry +0 +92 +6 +Connector_Molex +Molex_Sabre_46007-1102_1x02_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1102, 2 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +4 +2 +Connector_Molex +Molex_Sabre_46007-1102_1x02_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1102, With thermal vias in pads, 2 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +30 +2 +Connector_Molex +Molex_Sabre_46007-1103_1x03_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1103, 3 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +6 +3 +Connector_Molex +Molex_Sabre_46007-1103_1x03_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1103, With thermal vias in pads, 3 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +45 +3 +Connector_Molex +Molex_Sabre_46007-1104_1x04_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1104, 4 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +8 +4 +Connector_Molex +Molex_Sabre_46007-1104_1x04_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1104, With thermal vias in pads, 4 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +60 +4 +Connector_Molex +Molex_Sabre_46007-1105_1x05_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1105, 5 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +10 +5 +Connector_Molex +Molex_Sabre_46007-1105_1x05_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1105, With thermal vias in pads, 5 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +75 +5 +Connector_Molex +Molex_Sabre_46007-1106_1x06_P7.49mm_Horizontal +Molex Sabre Power Connector, 46007-1106, 6 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +12 +6 +Connector_Molex +Molex_Sabre_46007-1106_1x06_P7.49mm_Horizontal_ThermalVias +Molex Sabre Power Connector, 46007-1106, With thermal vias in pads, 6 Pins per row (http://www.molex.com/pdm_docs/sd/460071105_sd.pdf), generated with kicad-footprint-generator +connector Molex Sabre top entry +0 +90 +6 +Connector_Molex +Molex_SlimStack_52991-0208_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0208, 20 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +20 +20 +Connector_Molex +Molex_SlimStack_52991-0308_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0308, 30 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +30 +30 +Connector_Molex +Molex_SlimStack_52991-0408_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0408, 40 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +40 +40 +Connector_Molex +Molex_SlimStack_52991-0508_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0508, 50 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +50 +50 +Connector_Molex +Molex_SlimStack_52991-0608_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0608, 60 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +60 +60 +Connector_Molex +Molex_SlimStack_52991-0708_2x35_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0708, 70 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +70 +70 +Connector_Molex +Molex_SlimStack_52991-0808_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 52991-0808, 80 Pins (http://www.molex.com/pdm_docs/sd/529910308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +80 +80 +Connector_Molex +Molex_SlimStack_53748-0208_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0208, 20 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +20 +20 +Connector_Molex +Molex_SlimStack_53748-0308_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0308, 30 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +30 +30 +Connector_Molex +Molex_SlimStack_53748-0408_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0408, 40 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +40 +40 +Connector_Molex +Molex_SlimStack_53748-0608_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0608, 60 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +60 +60 +Connector_Molex +Molex_SlimStack_53748-0708_2x35_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0708, 70 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +70 +70 +Connector_Molex +Molex_SlimStack_53748-0808_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 53748-0808, 80 Pins (https://www.molex.com/pdm_docs/sd/537480308_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack vertical +0 +80 +80 +Connector_Molex +Molex_SlimStack_54722-0164_2x08_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0164, 16 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +16 +16 +Connector_Molex +Molex_SlimStack_54722-0204_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0204, 20 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_54722-0224_2x11_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0224, 22 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_54722-0244_2x12_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0244, 24 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_54722-0304_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0304, 30 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_54722-0344_2x17_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0344, 34 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_54722-0404_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0404, 40 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_54722-0504_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0504, 50 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_54722-0604_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0604, 60 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_54722-0804_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 54722-0804, 80 Pins (http://www.molex.com/pdm_docs/sd/547220804_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_Molex +Molex_SlimStack_55560-0161_2x08_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0161, 16 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +16 +16 +Connector_Molex +Molex_SlimStack_55560-0201_2x10_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0201, 20 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_55560-0221_2x11_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0221, 22 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_55560-0241_2x12_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0241, 24 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_55560-0301_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0301, 30 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_55560-0341_2x17_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0341, 34 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_55560-0401_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0401, 40 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_55560-0501_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0501, 50 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_55560-0601_2x30_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0601, 60 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_55560-0801_2x40_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 55560-0801, 80 Pins (http://www.molex.com/pdm_docs/sd/555600207_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_Molex +Molex_SlimStack_501920-3001_2x15_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 501920-3001, 30 Pins (http://www.molex.com/pdm_docs/sd/5019204001_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_501920-4001_2x20_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 501920-4001, 40 Pins (http://www.molex.com/pdm_docs/sd/5019204001_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_501920-5001_2x25_P0.50mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 501920-5001, 50 Pins (http://www.molex.com/pdm_docs/sd/5019204001_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_502426-0810_2x04_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-0810, 8 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +8 +8 +Connector_Molex +Molex_SlimStack_502426-1410_2x07_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-1410, 14 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +14 +14 +Connector_Molex +Molex_SlimStack_502426-2010_2x10_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2010, 20 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_502426-2210_2x11_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2210, 22 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_502426-2410_2x12_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2410, 24 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_502426-2610_2x13_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-2610, 26 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +26 +26 +Connector_Molex +Molex_SlimStack_502426-3010_2x15_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-3010, 30 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_502426-3210_2x16_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-3210, 32 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +32 +32 +Connector_Molex +Molex_SlimStack_502426-3410_2x17_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-3410, 34 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_502426-4010_2x20_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-4010, 40 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_502426-4410_2x22_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-4410, 44 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +44 +44 +Connector_Molex +Molex_SlimStack_502426-5010_2x25_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-5010, 50 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_502426-6010_2x30_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-6010, 60 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_502426-6410_2x32_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-6410, 64 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +64 +64 +Connector_Molex +Molex_SlimStack_502426-8010_2x40_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502426-8010, 80 Pins (http://www.molex.com/pdm_docs/sd/5024260810_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_Molex +Molex_SlimStack_502430-0820_2x04_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-0820, 8 Pins (http://www.molex.com/pdm_docs/sd/5024300820_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +8 +8 +Connector_Molex +Molex_SlimStack_502430-1410_2x07_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-1410, 14 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +14 +14 +Connector_Molex +Molex_SlimStack_502430-2010_2x10_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2010, 20 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +20 +20 +Connector_Molex +Molex_SlimStack_502430-2210_2x11_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2210, 22 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +22 +22 +Connector_Molex +Molex_SlimStack_502430-2410_2x12_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2410, 24 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +24 +24 +Connector_Molex +Molex_SlimStack_502430-2610_2x13_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-2610, 26 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +26 +26 +Connector_Molex +Molex_SlimStack_502430-3010_2x15_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-3010, 30 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +30 +30 +Connector_Molex +Molex_SlimStack_502430-3210_2x16_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-3210, 32 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +32 +32 +Connector_Molex +Molex_SlimStack_502430-3410_2x17_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-3410, 34 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +34 +34 +Connector_Molex +Molex_SlimStack_502430-4010_2x20_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-4010, 40 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +40 +40 +Connector_Molex +Molex_SlimStack_502430-4410_2x22_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-4410, 44 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +44 +44 +Connector_Molex +Molex_SlimStack_502430-5010_2x25_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-5010, 50 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +50 +50 +Connector_Molex +Molex_SlimStack_502430-6010_2x30_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-6010, 60 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +60 +60 +Connector_Molex +Molex_SlimStack_502430-6410_2x32_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-6410, 64 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +64 +64 +Connector_Molex +Molex_SlimStack_502430-8010_2x40_P0.40mm_Vertical +Molex SlimStack Fine-Pitch SMT Board-to-Board Connectors, 502430-8010, 80 Pins (http://www.molex.com/pdm_docs/sd/5024301410_sd.pdf), generated with kicad-footprint-generator +connector Molex SlimStack side entry +0 +80 +80 +Connector_PCBEdge +4UCON_10156_2x40_P1.27mm_Socket_Horizontal +4UCON 10156 Card edge socket with 80 contacts (40 each side), through-hole, http://www.4uconnector.com/online/object/4udrawing/10156.pdf +4UCON 10156 Card edge socket with 80 contacts +0 +80 +80 +Connector_PCBEdge +BUS_AT +AT ISA 16 bits Bus Edge Connector +BUS ISA AT Edge connector +0 +98 +98 +Connector_PCBEdge +BUS_PCI +PCI bus Edge Connector +PCI bus Edge Connector +0 +240 +120 +Connector_PCBEdge +BUS_PCI_Express_Mini +Mini-PCI Express bus connector (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=11) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Dual +Mini-PCI Express bus connector full size with dual clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=28) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Full +Mini-PCI Express bus connector full size with clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=24) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Half +Mini-PCI Express bus connector half size with clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=25) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCIexpress_x1 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +36 +36 +Connector_PCBEdge +BUS_PCIexpress_x4 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +64 +64 +Connector_PCBEdge +BUS_PCIexpress_x8 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +98 +98 +Connector_PCBEdge +BUS_PCIexpress_x16 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +164 +164 +Connector_PCBEdge +Samtec_MECF-05-0_-L-DV_2x05_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-0_-NP-L-DV_2x05_P1.27mm_Edge +Highspeed card edge connector for PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-05-01-L-DV-WT_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +10 +8 +Connector_PCBEdge +Samtec_MECF-05-01-L-DV_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-01-NP-L-DV-WT_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +12 +10 +Connector_PCBEdge +Samtec_MECF-05-01-NP-L-DV_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-05-02-L-DV-WT_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +10 +8 +Connector_PCBEdge +Samtec_MECF-05-02-L-DV_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-02-NP-L-DV-WT_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +12 +10 +Connector_PCBEdge +Samtec_MECF-05-02-NP-L-DV_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-08-0_-L-DV_2x08_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-0_-NP-L-DV_2x08_P1.27mm_Edge +Highspeed card edge connector for PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-08-01-L-DV-WT_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +16 +14 +Connector_PCBEdge +Samtec_MECF-08-01-L-DV_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-01-NP-L-DV-WT_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +18 +16 +Connector_PCBEdge +Samtec_MECF-08-01-NP-L-DV_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-08-02-L-DV-WT_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +16 +14 +Connector_PCBEdge +Samtec_MECF-08-02-L-DV_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-02-NP-L-DV-WT_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +18 +16 +Connector_PCBEdge +Samtec_MECF-08-02-NP-L-DV_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-20-0_-L-DV_2x20_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-0_-NP-L-DV_2x20_P1.27mm_Edge +Highspeed card edge connector for PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-20-01-L-DV-WT_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +40 +38 +Connector_PCBEdge +Samtec_MECF-20-01-L-DV_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-01-NP-L-DV-WT_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +42 +40 +Connector_PCBEdge +Samtec_MECF-20-01-NP-L-DV_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-20-02-L-DV-WT_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +40 +38 +Connector_PCBEdge +Samtec_MECF-20-02-L-DV_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-02-NP-L-DV-WT_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +42 +40 +Connector_PCBEdge +Samtec_MECF-20-02-NP-L-DV_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-30-0_-L-DV_2x30_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-0_-NP-L-DV_2x30_P1.27mm_Edge +Highspeed card edge connector for PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-30-01-L-DV-WT_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +60 +58 +Connector_PCBEdge +Samtec_MECF-30-01-L-DV_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-01-NP-L-DV-WT_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +62 +60 +Connector_PCBEdge +Samtec_MECF-30-01-NP-L-DV_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-30-02-L-DV-WT_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +60 +58 +Connector_PCBEdge +Samtec_MECF-30-02-L-DV_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-02-NP-L-DV-WT_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +62 +60 +Connector_PCBEdge +Samtec_MECF-30-02-NP-L-DV_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-40-0_-L-DV_2x40_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-0_-NP-L-DV_2x40_P1.27mm_Edge +Highspeed card edge connector for PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-40-01-L-DV-WT_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +80 +78 +Connector_PCBEdge +Samtec_MECF-40-01-L-DV_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-01-NP-L-DV-WT_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +82 +80 +Connector_PCBEdge +Samtec_MECF-40-01-NP-L-DV_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-40-02-L-DV-WT_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +80 +78 +Connector_PCBEdge +Samtec_MECF-40-02-L-DV_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-02-NP-L-DV-WT_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +82 +80 +Connector_PCBEdge +Samtec_MECF-40-02-NP-L-DV_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-50-0_-L-DV_2x50_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-0_-NP-L-DV_2x50_P1.27mm_Edge +Highspeed card edge connector for PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-50-01-L-DV-WT_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +100 +98 +Connector_PCBEdge +Samtec_MECF-50-01-L-DV_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-01-NP-L-DV-WT_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +102 +100 +Connector_PCBEdge +Samtec_MECF-50-01-NP-L-DV_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-50-02-L-DV-WT_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +100 +98 +Connector_PCBEdge +Samtec_MECF-50-02-L-DV_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-02-NP-L-DV-WT_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +102 +100 +Connector_PCBEdge +Samtec_MECF-50-02-NP-L-DV_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-60-0_-L-DV_2x60_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-0_-NP-L-DV_2x60_P1.27mm_Edge +Highspeed card edge connector for PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-60-01-L-DV-WT_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +118 +116 +Connector_PCBEdge +Samtec_MECF-60-01-L-DV_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-01-NP-L-DV-WT_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +122 +120 +Connector_PCBEdge +Samtec_MECF-60-01-NP-L-DV_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-60-02-L-DV-WT_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +118 +116 +Connector_PCBEdge +Samtec_MECF-60-02-L-DV_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-02-NP-L-DV-WT_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +122 +120 +Connector_PCBEdge +Samtec_MECF-60-02-NP-L-DV_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-70-0_-L-DV_2x70_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-0_-NP-L-DV_2x70_P1.27mm_Edge +Highspeed card edge connector for PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +Samtec_MECF-70-01-L-DV-WT_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +138 +136 +Connector_PCBEdge +Samtec_MECF-70-01-L-DV_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-01-NP-L-DV-WT_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +142 +140 +Connector_PCBEdge +Samtec_MECF-70-01-NP-L-DV_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +Samtec_MECF-70-02-L-DV-WT_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +138 +136 +Connector_PCBEdge +Samtec_MECF-70-02-L-DV_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-02-NP-L-DV-WT_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +142 +140 +Connector_PCBEdge +Samtec_MECF-70-02-NP-L-DV_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +molex_EDGELOCK_2-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +2 +2 +Connector_PCBEdge +molex_EDGELOCK_4-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +4 +4 +Connector_PCBEdge +molex_EDGELOCK_6-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +6 +6 +Connector_PCBEdge +molex_EDGELOCK_8-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_2-G-7,62_1x02_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/2-G-7,62; number of pins: 02; pin pitch: 7.62mm; Angled || order number: 1766233 12A 630V +phoenix_contact connector GMSTBA_01x02_G_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_2-G_1x02_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/2-G; number of pins: 02; pin pitch: 7.50mm; Angled || order number: 1766343 12A 630V +phoenix_contact connector GMSTBA_01x02_G_7.50mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_3-G-7,62_1x03_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/3-G-7,62; number of pins: 03; pin pitch: 7.62mm; Angled || order number: 1766246 12A 630V +phoenix_contact connector GMSTBA_01x03_G_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_3-G_1x03_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/3-G; number of pins: 03; pin pitch: 7.50mm; Angled || order number: 1766356 12A 630V +phoenix_contact connector GMSTBA_01x03_G_7.50mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_4-G-7,62_1x04_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/4-G-7,62; number of pins: 04; pin pitch: 7.62mm; Angled || order number: 1766259 12A 630V +phoenix_contact connector GMSTBA_01x04_G_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_4-G_1x04_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/4-G; number of pins: 04; pin pitch: 7.50mm; Angled || order number: 1766369 12A 630V +phoenix_contact connector GMSTBA_01x04_G_7.50mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_5-G-7,62_1x05_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/5-G-7,62; number of pins: 05; pin pitch: 7.62mm; Angled || order number: 1766262 12A 630V +phoenix_contact connector GMSTBA_01x05_G_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_5-G_1x05_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/5-G; number of pins: 05; pin pitch: 7.50mm; Angled || order number: 1766372 12A 630V +phoenix_contact connector GMSTBA_01x05_G_7.50mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_6-G-7,62_1x06_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/6-G-7,62; number of pins: 06; pin pitch: 7.62mm; Angled || order number: 1766275 12A 630V +phoenix_contact connector GMSTBA_01x06_G_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_6-G_1x06_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/6-G; number of pins: 06; pin pitch: 7.50mm; Angled || order number: 1766385 12A 630V +phoenix_contact connector GMSTBA_01x06_G_7.50mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_7-G-7,62_1x07_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/7-G-7,62; number of pins: 07; pin pitch: 7.62mm; Angled || order number: 1766288 12A 630V +phoenix_contact connector GMSTBA_01x07_G_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_7-G_1x07_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/7-G; number of pins: 07; pin pitch: 7.50mm; Angled || order number: 1766398 12A 630V +phoenix_contact connector GMSTBA_01x07_G_7.50mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_8-G-7,62_1x08_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/8-G-7,62; number of pins: 08; pin pitch: 7.62mm; Angled || order number: 1766291 12A 630V +phoenix_contact connector GMSTBA_01x08_G_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_8-G_1x08_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/8-G; number of pins: 08; pin pitch: 7.50mm; Angled || order number: 1766408 12A 630V +phoenix_contact connector GMSTBA_01x08_G_7.50mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_9-G-7,62_1x09_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/9-G-7,62; number of pins: 09; pin pitch: 7.62mm; Angled || order number: 1766301 12A 630V +phoenix_contact connector GMSTBA_01x09_G_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_9-G_1x09_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/9-G; number of pins: 09; pin pitch: 7.50mm; Angled || order number: 1766411 12A 630V +phoenix_contact connector GMSTBA_01x09_G_7.50mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_10-G-7,62_1x10_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/10-G-7,62; number of pins: 10; pin pitch: 7.62mm; Angled || order number: 1766314 12A 630V +phoenix_contact connector GMSTBA_01x10_G_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_10-G_1x10_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/10-G; number of pins: 10; pin pitch: 7.50mm; Angled || order number: 1766424 12A 630V +phoenix_contact connector GMSTBA_01x10_G_7.50mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_11-G-7,62_1x11_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/11-G-7,62; number of pins: 11; pin pitch: 7.62mm; Angled || order number: 1766327 12A 630V +phoenix_contact connector GMSTBA_01x11_G_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_11-G_1x11_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/11-G; number of pins: 11; pin pitch: 7.50mm; Angled || order number: 1766437 12A 630V +phoenix_contact connector GMSTBA_01x11_G_7.50mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_12-G-7,62_1x12_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/12-G-7,62; number of pins: 12; pin pitch: 7.62mm; Angled || order number: 1766330 12A 630V +phoenix_contact connector GMSTBA_01x12_G_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_12-G_1x12_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/12-G; number of pins: 12; pin pitch: 7.50mm; Angled || order number: 1766440 12A 630V +phoenix_contact connector GMSTBA_01x12_G_7.50mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_2-G-7,62_1x02_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/2-G-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical || order number: 1766770 12A 630V +phoenix_contact connector GMSTBVA_01x02_G_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_2-G_1x02_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/2-G; number of pins: 02; pin pitch: 7.50mm; Vertical || order number: 1766660 12A 630V +phoenix_contact connector GMSTBVA_01x02_G_7.50mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_3-G-7,62_1x03_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/3-G-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical || order number: 1766783 12A 630V +phoenix_contact connector GMSTBVA_01x03_G_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_3-G_1x03_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/3-G; number of pins: 03; pin pitch: 7.50mm; Vertical || order number: 1766673 12A 630V +phoenix_contact connector GMSTBVA_01x03_G_7.50mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_4-G-7,62_1x04_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/4-G-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical || order number: 1766796 12A 630V +phoenix_contact connector GMSTBVA_01x04_G_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_4-G_1x04_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/4-G; number of pins: 04; pin pitch: 7.50mm; Vertical || order number: 1766686 12A 630V +phoenix_contact connector GMSTBVA_01x04_G_7.50mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_5-G-7,62_1x05_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/5-G-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical || order number: 1766806 12A 630V +phoenix_contact connector GMSTBVA_01x05_G_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_5-G_1x05_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/5-G; number of pins: 05; pin pitch: 7.50mm; Vertical || order number: 1766699 12A 630V +phoenix_contact connector GMSTBVA_01x05_G_7.50mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_6-G-7,62_1x06_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/6-G-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical || order number: 1766819 12A 630V +phoenix_contact connector GMSTBVA_01x06_G_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_6-G_1x06_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/6-G; number of pins: 06; pin pitch: 7.50mm; Vertical || order number: 1766709 12A 630V +phoenix_contact connector GMSTBVA_01x06_G_7.50mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_7-G-7,62_1x07_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/7-G-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical || order number: 1766822 12A 630V +phoenix_contact connector GMSTBVA_01x07_G_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_7-G_1x07_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/7-G; number of pins: 07; pin pitch: 7.50mm; Vertical || order number: 1766712 12A 630V +phoenix_contact connector GMSTBVA_01x07_G_7.50mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_8-G-7,62_1x08_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/8-G-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical || order number: 1766835 12A 630V +phoenix_contact connector GMSTBVA_01x08_G_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_8-G_1x08_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/8-G; number of pins: 08; pin pitch: 7.50mm; Vertical || order number: 1766725 12A 630V +phoenix_contact connector GMSTBVA_01x08_G_7.50mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_9-G-7,62_1x09_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/9-G-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical || order number: 1766848 12A 630V +phoenix_contact connector GMSTBVA_01x09_G_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_9-G_1x09_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/9-G; number of pins: 09; pin pitch: 7.50mm; Vertical || order number: 1766738 12A 630V +phoenix_contact connector GMSTBVA_01x09_G_7.50mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_10-G-7,62_1x10_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/10-G-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical || order number: 1766851 12A 630V +phoenix_contact connector GMSTBVA_01x10_G_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_10-G_1x10_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/10-G; number of pins: 10; pin pitch: 7.50mm; Vertical || order number: 1766741 12A 630V +phoenix_contact connector GMSTBVA_01x10_G_7.50mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_11-G-7,62_1x11_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/11-G-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical || order number: 1766864 12A 630V +phoenix_contact connector GMSTBVA_01x11_G_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_11-G_1x11_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/11-G; number of pins: 11; pin pitch: 7.50mm; Vertical || order number: 1766754 12A 630V +phoenix_contact connector GMSTBVA_01x11_G_7.50mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_12-G-7,62_1x12_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/12-G-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical || order number: 1766877 12A 630V +phoenix_contact connector GMSTBVA_01x12_G_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_12-G_1x12_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/12-G; number of pins: 12; pin pitch: 7.50mm; Vertical || order number: 1766767 12A 630V +phoenix_contact connector GMSTBVA_01x12_G_7.50mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_2-GF-7,62_1x02_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829154 12A 630V +phoenix_contact connector GMSTBV_01x02_GF_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_2-GF-7,62_1x02_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829154 12A 630V +phoenix_contact connector GMSTBV_01x02_GF_7.62mm_MH +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_3-GF-7,62_1x03_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829167 12A 630V +phoenix_contact connector GMSTBV_01x03_GF_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_3-GF-7,62_1x03_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829167 12A 630V +phoenix_contact connector GMSTBV_01x03_GF_7.62mm_MH +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_4-GF-7,62_1x04_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829170 12A 630V +phoenix_contact connector GMSTBV_01x04_GF_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_4-GF-7,62_1x04_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829170 12A 630V +phoenix_contact connector GMSTBV_01x04_GF_7.62mm_MH +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_5-GF-7,62_1x05_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829183 12A 630V +phoenix_contact connector GMSTBV_01x05_GF_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_5-GF-7,62_1x05_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829183 12A 630V +phoenix_contact connector GMSTBV_01x05_GF_7.62mm_MH +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_6-GF-7,62_1x06_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829196 12A 630V +phoenix_contact connector GMSTBV_01x06_GF_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_6-GF-7,62_1x06_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829196 12A 630V +phoenix_contact connector GMSTBV_01x06_GF_7.62mm_MH +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_7-GF-7,62_1x07_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829206 12A 630V +phoenix_contact connector GMSTBV_01x07_GF_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_7-GF-7,62_1x07_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829206 12A 630V +phoenix_contact connector GMSTBV_01x07_GF_7.62mm_MH +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_8-GF-7,62_1x08_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829219 12A 630V +phoenix_contact connector GMSTBV_01x08_GF_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_8-GF-7,62_1x08_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829219 12A 630V +phoenix_contact connector GMSTBV_01x08_GF_7.62mm_MH +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_9-GF-7,62_1x09_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829222 12A 630V +phoenix_contact connector GMSTBV_01x09_GF_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_9-GF-7,62_1x09_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829222 12A 630V +phoenix_contact connector GMSTBV_01x09_GF_7.62mm_MH +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_10-GF-7,62_1x10_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829235 12A 630V +phoenix_contact connector GMSTBV_01x10_GF_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_10-GF-7,62_1x10_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829235 12A 630V +phoenix_contact connector GMSTBV_01x10_GF_7.62mm_MH +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_11-GF-7,62_1x11_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829248 12A 630V +phoenix_contact connector GMSTBV_01x11_GF_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_11-GF-7,62_1x11_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829248 12A 630V +phoenix_contact connector GMSTBV_01x11_GF_7.62mm_MH +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_12-GF-7,62_1x12_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829251 12A 630V +phoenix_contact connector GMSTBV_01x12_GF_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_12-GF-7,62_1x12_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829251 12A 630V +phoenix_contact connector GMSTBV_01x12_GF_7.62mm_MH +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_2-GF-7,62_1x02_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806229 12A 630V +phoenix_contact connector GMSTB_01x02_GF_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_2-GF-7,62_1x02_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806229 12A 630V +phoenix_contact connector GMSTB_01x02_GF_7.62mm_MH +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_3-GF-7,62_1x03_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806232 12A 630V +phoenix_contact connector GMSTB_01x03_GF_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_3-GF-7,62_1x03_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806232 12A 630V +phoenix_contact connector GMSTB_01x03_GF_7.62mm_MH +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_4-GF-7,62_1x04_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806245 12A 630V +phoenix_contact connector GMSTB_01x04_GF_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_4-GF-7,62_1x04_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806245 12A 630V +phoenix_contact connector GMSTB_01x04_GF_7.62mm_MH +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_5-GF-7,62_1x05_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806258 12A 630V +phoenix_contact connector GMSTB_01x05_GF_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_5-GF-7,62_1x05_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806258 12A 630V +phoenix_contact connector GMSTB_01x05_GF_7.62mm_MH +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_6-GF-7,62_1x06_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806261 12A 630V +phoenix_contact connector GMSTB_01x06_GF_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_6-GF-7,62_1x06_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806261 12A 630V +phoenix_contact connector GMSTB_01x06_GF_7.62mm_MH +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_7-GF-7,62_1x07_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806274 12A 630V +phoenix_contact connector GMSTB_01x07_GF_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_7-GF-7,62_1x07_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806274 12A 630V +phoenix_contact connector GMSTB_01x07_GF_7.62mm_MH +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_8-GF-7,62_1x08_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806287 12A 630V +phoenix_contact connector GMSTB_01x08_GF_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_8-GF-7,62_1x08_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806287 12A 630V +phoenix_contact connector GMSTB_01x08_GF_7.62mm_MH +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_9-GF-7,62_1x09_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806290 12A 630V +phoenix_contact connector GMSTB_01x09_GF_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_9-GF-7,62_1x09_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806290 12A 630V +phoenix_contact connector GMSTB_01x09_GF_7.62mm_MH +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_10-GF-7,62_1x10_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806300 12A 630V +phoenix_contact connector GMSTB_01x10_GF_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_10-GF-7,62_1x10_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806300 12A 630V +phoenix_contact connector GMSTB_01x10_GF_7.62mm_MH +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_11-GF-7,62_1x11_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806313 12A 630V +phoenix_contact connector GMSTB_01x11_GF_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_11-GF-7,62_1x11_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806313 12A 630V +phoenix_contact connector GMSTB_01x11_GF_7.62mm_MH +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_12-GF-7,62_1x12_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806326 12A 630V +phoenix_contact connector GMSTB_01x12_GF_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_12-GF-7,62_1x12_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806326 12A 630V +phoenix_contact connector GMSTB_01x12_GF_7.62mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-G-3.5_1x02_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical || order number: 1843606 8A 160V +phoenix_contact connector MCV_01x02_G_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-G-3.81_1x02_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical || order number: 1803426 8A 160V +phoenix_contact connector MCV_01x02_G_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.5_1x02_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843224 8A 160V +phoenix_contact connector MCV_01x02_GF_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.5_1x02_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843224 8A 160V +phoenix_contact connector MCV_01x02_GF_3.5mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.81_1x02_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830596 8A 160V +phoenix_contact connector MCV_01x02_GF_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.81_1x02_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830596 8A 160V +phoenix_contact connector MCV_01x02_GF_3.81mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-G-3.5_1x03_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical || order number: 1843619 8A 160V +phoenix_contact connector MCV_01x03_G_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-G-3.81_1x03_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical || order number: 1803439 8A 160V +phoenix_contact connector MCV_01x03_G_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.5_1x03_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843237 8A 160V +phoenix_contact connector MCV_01x03_GF_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.5_1x03_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843237 8A 160V +phoenix_contact connector MCV_01x03_GF_3.5mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.81_1x03_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830606 8A 160V +phoenix_contact connector MCV_01x03_GF_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.81_1x03_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830606 8A 160V +phoenix_contact connector MCV_01x03_GF_3.81mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-G-3.5_1x04_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical || order number: 1843622 8A 160V +phoenix_contact connector MCV_01x04_G_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-G-3.81_1x04_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical || order number: 1803442 8A 160V +phoenix_contact connector MCV_01x04_G_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.5_1x04_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843240 8A 160V +phoenix_contact connector MCV_01x04_GF_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.5_1x04_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843240 8A 160V +phoenix_contact connector MCV_01x04_GF_3.5mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.81_1x04_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830619 8A 160V +phoenix_contact connector MCV_01x04_GF_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.81_1x04_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830619 8A 160V +phoenix_contact connector MCV_01x04_GF_3.81mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-G-3.5_1x05_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical || order number: 1843635 8A 160V +phoenix_contact connector MCV_01x05_G_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-G-3.81_1x05_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical || order number: 1803455 8A 160V +phoenix_contact connector MCV_01x05_G_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.5_1x05_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843253 8A 160V +phoenix_contact connector MCV_01x05_GF_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.5_1x05_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843253 8A 160V +phoenix_contact connector MCV_01x05_GF_3.5mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.81_1x05_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830622 8A 160V +phoenix_contact connector MCV_01x05_GF_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.81_1x05_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830622 8A 160V +phoenix_contact connector MCV_01x05_GF_3.81mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-G-3.5_1x06_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical || order number: 1843648 8A 160V +phoenix_contact connector MCV_01x06_G_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-G-3.81_1x06_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical || order number: 1803468 8A 160V +phoenix_contact connector MCV_01x06_G_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.5_1x06_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843266 8A 160V +phoenix_contact connector MCV_01x06_GF_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.5_1x06_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843266 8A 160V +phoenix_contact connector MCV_01x06_GF_3.5mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.81_1x06_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830635 8A 160V +phoenix_contact connector MCV_01x06_GF_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.81_1x06_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830635 8A 160V +phoenix_contact connector MCV_01x06_GF_3.81mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-G-3.5_1x07_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical || order number: 1843651 8A 160V +phoenix_contact connector MCV_01x07_G_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-G-3.81_1x07_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical || order number: 1803471 8A 160V +phoenix_contact connector MCV_01x07_G_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.5_1x07_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843279 8A 160V +phoenix_contact connector MCV_01x07_GF_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.5_1x07_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843279 8A 160V +phoenix_contact connector MCV_01x07_GF_3.5mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.81_1x07_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830648 8A 160V +phoenix_contact connector MCV_01x07_GF_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.81_1x07_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830648 8A 160V +phoenix_contact connector MCV_01x07_GF_3.81mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-G-3.5_1x08_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical || order number: 1843664 8A 160V +phoenix_contact connector MCV_01x08_G_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-G-3.81_1x08_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical || order number: 1803484 8A 160V +phoenix_contact connector MCV_01x08_G_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.5_1x08_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843282 8A 160V +phoenix_contact connector MCV_01x08_GF_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.5_1x08_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843282 8A 160V +phoenix_contact connector MCV_01x08_GF_3.5mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.81_1x08_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830651 8A 160V +phoenix_contact connector MCV_01x08_GF_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.81_1x08_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830651 8A 160V +phoenix_contact connector MCV_01x08_GF_3.81mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-G-3.5_1x09_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical || order number: 1843677 8A 160V +phoenix_contact connector MCV_01x09_G_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-G-3.81_1x09_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical || order number: 1803497 8A 160V +phoenix_contact connector MCV_01x09_G_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.5_1x09_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843295 8A 160V +phoenix_contact connector MCV_01x09_GF_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.5_1x09_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843295 8A 160V +phoenix_contact connector MCV_01x09_GF_3.5mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.81_1x09_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830664 8A 160V +phoenix_contact connector MCV_01x09_GF_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.81_1x09_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830664 8A 160V +phoenix_contact connector MCV_01x09_GF_3.81mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-G-3.5_1x10_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical || order number: 1843680 8A 160V +phoenix_contact connector MCV_01x10_G_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-G-3.81_1x10_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical || order number: 1803507 8A 160V +phoenix_contact connector MCV_01x10_G_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.5_1x10_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843305 8A 160V +phoenix_contact connector MCV_01x10_GF_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.5_1x10_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843305 8A 160V +phoenix_contact connector MCV_01x10_GF_3.5mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.81_1x10_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830677 8A 160V +phoenix_contact connector MCV_01x10_GF_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.81_1x10_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830677 8A 160V +phoenix_contact connector MCV_01x10_GF_3.81mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-G-3.5_1x11_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical || order number: 1843693 8A 160V +phoenix_contact connector MCV_01x11_G_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-G-3.81_1x11_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical || order number: 1803510 8A 160V +phoenix_contact connector MCV_01x11_G_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.5_1x11_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843318 8A 160V +phoenix_contact connector MCV_01x11_GF_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.5_1x11_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843318 8A 160V +phoenix_contact connector MCV_01x11_GF_3.5mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.81_1x11_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830680 8A 160V +phoenix_contact connector MCV_01x11_GF_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.81_1x11_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830680 8A 160V +phoenix_contact connector MCV_01x11_GF_3.81mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-G-3.5_1x12_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical || order number: 1843703 8A 160V +phoenix_contact connector MCV_01x12_G_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-G-3.81_1x12_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical || order number: 1803523 8A 160V +phoenix_contact connector MCV_01x12_G_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.5_1x12_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843321 8A 160V +phoenix_contact connector MCV_01x12_GF_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.5_1x12_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843321 8A 160V +phoenix_contact connector MCV_01x12_GF_3.5mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.81_1x12_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830693 8A 160V +phoenix_contact connector MCV_01x12_GF_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.81_1x12_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830693 8A 160V +phoenix_contact connector MCV_01x12_GF_3.81mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-G-3.5_1x13_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/13-G-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical || order number: 1843716 8A 160V +phoenix_contact connector MCV_01x13_G_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-G-3.81_1x13_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/13-G-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical || order number: 1803536 8A 160V +phoenix_contact connector MCV_01x13_G_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.5_1x13_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843334 8A 160V +phoenix_contact connector MCV_01x13_GF_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.5_1x13_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843334 8A 160V +phoenix_contact connector MCV_01x13_GF_3.5mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.81_1x13_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830703 8A 160V +phoenix_contact connector MCV_01x13_GF_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.81_1x13_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830703 8A 160V +phoenix_contact connector MCV_01x13_GF_3.81mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-G-3.5_1x14_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/14-G-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical || order number: 1843729 8A 160V +phoenix_contact connector MCV_01x14_G_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-G-3.81_1x14_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/14-G-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical || order number: 1803549 8A 160V +phoenix_contact connector MCV_01x14_G_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.5_1x14_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843347 8A 160V +phoenix_contact connector MCV_01x14_GF_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.5_1x14_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843347 8A 160V +phoenix_contact connector MCV_01x14_GF_3.5mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.81_1x14_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830716 8A 160V +phoenix_contact connector MCV_01x14_GF_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.81_1x14_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830716 8A 160V +phoenix_contact connector MCV_01x14_GF_3.81mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-G-3.5_1x15_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/15-G-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical || order number: 1843732 8A 160V +phoenix_contact connector MCV_01x15_G_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-G-3.81_1x15_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/15-G-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical || order number: 1803552 8A 160V +phoenix_contact connector MCV_01x15_G_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.5_1x15_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843350 8A 160V +phoenix_contact connector MCV_01x15_GF_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.5_1x15_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843350 8A 160V +phoenix_contact connector MCV_01x15_GF_3.5mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.81_1x15_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830729 8A 160V +phoenix_contact connector MCV_01x15_GF_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.81_1x15_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830729 8A 160V +phoenix_contact connector MCV_01x15_GF_3.81mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-G-3.5_1x16_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/16-G-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical || order number: 1843745 8A 160V +phoenix_contact connector MCV_01x16_G_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-G-3.81_1x16_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/16-G-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical || order number: 1803565 8A 160V +phoenix_contact connector MCV_01x16_G_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.5_1x16_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843363 8A 160V +phoenix_contact connector MCV_01x16_GF_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.5_1x16_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843363 8A 160V +phoenix_contact connector MCV_01x16_GF_3.5mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.81_1x16_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830732 8A 160V +phoenix_contact connector MCV_01x16_GF_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.81_1x16_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830732 8A 160V +phoenix_contact connector MCV_01x16_GF_3.81mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-G-3.5_1x02_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-3.5; number of pins: 02; pin pitch: 3.50mm; Angled || order number: 1844210 8A 160V +phoenix_contact connector MC_01x02_G_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-G-3.81_1x02_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-3.81; number of pins: 02; pin pitch: 3.81mm; Angled || order number: 1803277 8A 160V +phoenix_contact connector MC_01x02_G_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.5_1x02_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843790 8A 160V +phoenix_contact connector MC_01x02_GF_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.5_1x02_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843790 8A 160V +phoenix_contact connector MC_01x02_GF_3.5mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.81_1x02_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827868 8A 160V +phoenix_contact connector MC_01x02_GF_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.81_1x02_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827868 8A 160V +phoenix_contact connector MC_01x02_GF_3.81mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-G-3.5_1x03_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-3.5; number of pins: 03; pin pitch: 3.50mm; Angled || order number: 1844223 8A 160V +phoenix_contact connector MC_01x03_G_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-G-3.81_1x03_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-3.81; number of pins: 03; pin pitch: 3.81mm; Angled || order number: 1803280 8A 160V +phoenix_contact connector MC_01x03_G_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.5_1x03_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843800 8A 160V +phoenix_contact connector MC_01x03_GF_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.5_1x03_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843800 8A 160V +phoenix_contact connector MC_01x03_GF_3.5mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.81_1x03_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827871 8A 160V +phoenix_contact connector MC_01x03_GF_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.81_1x03_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827871 8A 160V +phoenix_contact connector MC_01x03_GF_3.81mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-G-3.5_1x04_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-3.5; number of pins: 04; pin pitch: 3.50mm; Angled || order number: 1844236 8A 160V +phoenix_contact connector MC_01x04_G_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-G-3.81_1x04_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-3.81; number of pins: 04; pin pitch: 3.81mm; Angled || order number: 1803293 8A 160V +phoenix_contact connector MC_01x04_G_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.5_1x04_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843813 8A 160V +phoenix_contact connector MC_01x04_GF_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.5_1x04_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843813 8A 160V +phoenix_contact connector MC_01x04_GF_3.5mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.81_1x04_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827884 8A 160V +phoenix_contact connector MC_01x04_GF_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.81_1x04_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827884 8A 160V +phoenix_contact connector MC_01x04_GF_3.81mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-G-3.5_1x05_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-3.5; number of pins: 05; pin pitch: 3.50mm; Angled || order number: 1844249 8A 160V +phoenix_contact connector MC_01x05_G_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-G-3.81_1x05_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-3.81; number of pins: 05; pin pitch: 3.81mm; Angled || order number: 1803303 8A 160V +phoenix_contact connector MC_01x05_G_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.5_1x05_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843826 8A 160V +phoenix_contact connector MC_01x05_GF_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.5_1x05_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843826 8A 160V +phoenix_contact connector MC_01x05_GF_3.5mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.81_1x05_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827897 8A 160V +phoenix_contact connector MC_01x05_GF_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.81_1x05_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827897 8A 160V +phoenix_contact connector MC_01x05_GF_3.81mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-G-3.5_1x06_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-3.5; number of pins: 06; pin pitch: 3.50mm; Angled || order number: 1844252 8A 160V +phoenix_contact connector MC_01x06_G_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-G-3.81_1x06_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-3.81; number of pins: 06; pin pitch: 3.81mm; Angled || order number: 1803316 8A 160V +phoenix_contact connector MC_01x06_G_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.5_1x06_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843839 8A 160V +phoenix_contact connector MC_01x06_GF_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.5_1x06_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843839 8A 160V +phoenix_contact connector MC_01x06_GF_3.5mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.81_1x06_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827907 8A 160V +phoenix_contact connector MC_01x06_GF_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.81_1x06_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827907 8A 160V +phoenix_contact connector MC_01x06_GF_3.81mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-G-3.5_1x07_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-3.5; number of pins: 07; pin pitch: 3.50mm; Angled || order number: 1844265 8A 160V +phoenix_contact connector MC_01x07_G_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-G-3.81_1x07_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-3.81; number of pins: 07; pin pitch: 3.81mm; Angled || order number: 1803329 8A 160V +phoenix_contact connector MC_01x07_G_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.5_1x07_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843842 8A 160V +phoenix_contact connector MC_01x07_GF_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.5_1x07_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843842 8A 160V +phoenix_contact connector MC_01x07_GF_3.5mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.81_1x07_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827910 8A 160V +phoenix_contact connector MC_01x07_GF_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.81_1x07_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827910 8A 160V +phoenix_contact connector MC_01x07_GF_3.81mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-G-3.5_1x08_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-3.5; number of pins: 08; pin pitch: 3.50mm; Angled || order number: 1844278 8A 160V +phoenix_contact connector MC_01x08_G_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-G-3.81_1x08_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-3.81; number of pins: 08; pin pitch: 3.81mm; Angled || order number: 1803332 8A 160V +phoenix_contact connector MC_01x08_G_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.5_1x08_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843855 8A 160V +phoenix_contact connector MC_01x08_GF_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.5_1x08_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843855 8A 160V +phoenix_contact connector MC_01x08_GF_3.5mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.81_1x08_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827923 8A 160V +phoenix_contact connector MC_01x08_GF_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.81_1x08_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827923 8A 160V +phoenix_contact connector MC_01x08_GF_3.81mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-G-3.5_1x09_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-3.5; number of pins: 09; pin pitch: 3.50mm; Angled || order number: 1844281 8A 160V +phoenix_contact connector MC_01x09_G_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-G-3.81_1x09_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-3.81; number of pins: 09; pin pitch: 3.81mm; Angled || order number: 1803345 8A 160V +phoenix_contact connector MC_01x09_G_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.5_1x09_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843868 8A 160V +phoenix_contact connector MC_01x09_GF_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.5_1x09_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843868 8A 160V +phoenix_contact connector MC_01x09_GF_3.5mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.81_1x09_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827936 8A 160V +phoenix_contact connector MC_01x09_GF_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.81_1x09_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827936 8A 160V +phoenix_contact connector MC_01x09_GF_3.81mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-G-3.5_1x10_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-3.5; number of pins: 10; pin pitch: 3.50mm; Angled || order number: 1844294 8A 160V +phoenix_contact connector MC_01x10_G_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-G-3.81_1x10_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-3.81; number of pins: 10; pin pitch: 3.81mm; Angled || order number: 1803358 8A 160V +phoenix_contact connector MC_01x10_G_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.5_1x10_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843871 8A 160V +phoenix_contact connector MC_01x10_GF_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.5_1x10_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843871 8A 160V +phoenix_contact connector MC_01x10_GF_3.5mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.81_1x10_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827949 8A 160V +phoenix_contact connector MC_01x10_GF_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.81_1x10_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827949 8A 160V +phoenix_contact connector MC_01x10_GF_3.81mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-G-3.5_1x11_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-3.5; number of pins: 11; pin pitch: 3.50mm; Angled || order number: 1844304 8A 160V +phoenix_contact connector MC_01x11_G_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-G-3.81_1x11_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-3.81; number of pins: 11; pin pitch: 3.81mm; Angled || order number: 1803361 8A 160V +phoenix_contact connector MC_01x11_G_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.5_1x11_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843884 8A 160V +phoenix_contact connector MC_01x11_GF_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.5_1x11_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843884 8A 160V +phoenix_contact connector MC_01x11_GF_3.5mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.81_1x11_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827952 8A 160V +phoenix_contact connector MC_01x11_GF_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.81_1x11_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827952 8A 160V +phoenix_contact connector MC_01x11_GF_3.81mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-G-3.5_1x12_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-3.5; number of pins: 12; pin pitch: 3.50mm; Angled || order number: 1844317 8A 160V +phoenix_contact connector MC_01x12_G_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-G-3.81_1x12_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-3.81; number of pins: 12; pin pitch: 3.81mm; Angled || order number: 1803374 8A 160V +phoenix_contact connector MC_01x12_G_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.5_1x12_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843897 8A 160V +phoenix_contact connector MC_01x12_GF_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.5_1x12_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843897 8A 160V +phoenix_contact connector MC_01x12_GF_3.5mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.81_1x12_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827965 8A 160V +phoenix_contact connector MC_01x12_GF_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.81_1x12_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827965 8A 160V +phoenix_contact connector MC_01x12_GF_3.81mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-G-3.5_1x13_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/13-G-3.5; number of pins: 13; pin pitch: 3.50mm; Angled || order number: 1844320 8A 160V +phoenix_contact connector MC_01x13_G_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-G-3.81_1x13_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/13-G-3.81; number of pins: 13; pin pitch: 3.81mm; Angled || order number: 1803387 8A 160V +phoenix_contact connector MC_01x13_G_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.5_1x13_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843907 8A 160V +phoenix_contact connector MC_01x13_GF_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.5_1x13_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843907 8A 160V +phoenix_contact connector MC_01x13_GF_3.5mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.81_1x13_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827978 8A 160V +phoenix_contact connector MC_01x13_GF_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.81_1x13_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827978 8A 160V +phoenix_contact connector MC_01x13_GF_3.81mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-G-3.5_1x14_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/14-G-3.5; number of pins: 14; pin pitch: 3.50mm; Angled || order number: 1844333 8A 160V +phoenix_contact connector MC_01x14_G_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-G-3.81_1x14_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/14-G-3.81; number of pins: 14; pin pitch: 3.81mm; Angled || order number: 1803390 8A 160V +phoenix_contact connector MC_01x14_G_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.5_1x14_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843910 8A 160V +phoenix_contact connector MC_01x14_GF_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.5_1x14_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843910 8A 160V +phoenix_contact connector MC_01x14_GF_3.5mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.81_1x14_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827981 8A 160V +phoenix_contact connector MC_01x14_GF_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.81_1x14_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827981 8A 160V +phoenix_contact connector MC_01x14_GF_3.81mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-G-3.5_1x15_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/15-G-3.5; number of pins: 15; pin pitch: 3.50mm; Angled || order number: 1844346 8A 160V +phoenix_contact connector MC_01x15_G_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-G-3.81_1x15_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/15-G-3.81; number of pins: 15; pin pitch: 3.81mm; Angled || order number: 1803400 8A 160V +phoenix_contact connector MC_01x15_G_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.5_1x15_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843923 8A 160V +phoenix_contact connector MC_01x15_GF_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.5_1x15_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843923 8A 160V +phoenix_contact connector MC_01x15_GF_3.5mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.81_1x15_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827994 8A 160V +phoenix_contact connector MC_01x15_GF_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.81_1x15_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827994 8A 160V +phoenix_contact connector MC_01x15_GF_3.81mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-G-3.5_1x16_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/16-G-3.5; number of pins: 16; pin pitch: 3.50mm; Angled || order number: 1844359 8A 160V +phoenix_contact connector MC_01x16_G_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-G-3.81_1x16_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/16-G-3.81; number of pins: 16; pin pitch: 3.81mm; Angled || order number: 1803413 8A 160V +phoenix_contact connector MC_01x16_G_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.5_1x16_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843936 8A 160V +phoenix_contact connector MC_01x16_GF_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.5_1x16_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843936 8A 160V +phoenix_contact connector MC_01x16_GF_3.5mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.81_1x16_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Angled; threaded flange || order number: 1828003 8A 160V +phoenix_contact connector MC_01x16_GF_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.81_1x16_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1828003 8A 160V +phoenix_contact connector MC_01x16_GF_3.81mm_MH +0 +16 +16 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-G-5.08_1x02_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical || order number: 1836299 8A 320V +phoenix_contact connector MCV_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-GF-5.08_1x02_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847615 8A 320V +phoenix_contact connector MCV_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-GF-5.08_1x02_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847615 8A 320V +phoenix_contact connector MCV_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-G-5.08_1x03_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical || order number: 1836309 8A 320V +phoenix_contact connector MCV_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-GF-5.08_1x03_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847628 8A 320V +phoenix_contact connector MCV_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-GF-5.08_1x03_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847628 8A 320V +phoenix_contact connector MCV_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-G-5.08_1x04_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical || order number: 1836312 8A 320V +phoenix_contact connector MCV_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-GF-5.08_1x04_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847631 8A 320V +phoenix_contact connector MCV_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-GF-5.08_1x04_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847631 8A 320V +phoenix_contact connector MCV_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-G-5.08_1x05_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical || order number: 1836325 8A 320V +phoenix_contact connector MCV_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-GF-5.08_1x05_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847644 8A 320V +phoenix_contact connector MCV_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-GF-5.08_1x05_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847644 8A 320V +phoenix_contact connector MCV_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-G-5.08_1x06_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical || order number: 1836338 8A 320V +phoenix_contact connector MCV_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-GF-5.08_1x06_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847657 8A 320V +phoenix_contact connector MCV_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-GF-5.08_1x06_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847657 8A 320V +phoenix_contact connector MCV_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-G-5.08_1x07_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical || order number: 1836341 8A 320V +phoenix_contact connector MCV_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-GF-5.08_1x07_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847660 8A 320V +phoenix_contact connector MCV_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-GF-5.08_1x07_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847660 8A 320V +phoenix_contact connector MCV_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-G-5.08_1x08_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical || order number: 1836354 8A 320V +phoenix_contact connector MCV_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-GF-5.08_1x08_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847673 8A 320V +phoenix_contact connector MCV_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-GF-5.08_1x08_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847673 8A 320V +phoenix_contact connector MCV_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-G-5.08_1x09_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical || order number: 1836367 8A 320V +phoenix_contact connector MCV_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-GF-5.08_1x09_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847686 8A 320V +phoenix_contact connector MCV_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-GF-5.08_1x09_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847686 8A 320V +phoenix_contact connector MCV_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-G-5.08_1x10_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical || order number: 1836370 8A 320V +phoenix_contact connector MCV_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-GF-5.08_1x10_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847699 8A 320V +phoenix_contact connector MCV_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-GF-5.08_1x10_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847699 8A 320V +phoenix_contact connector MCV_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-G-5.08_1x11_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical || order number: 1836383 8A 320V +phoenix_contact connector MCV_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-GF-5.08_1x11_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847709 8A 320V +phoenix_contact connector MCV_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-GF-5.08_1x11_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847709 8A 320V +phoenix_contact connector MCV_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-G-5.08_1x12_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical || order number: 1836396 8A 320V +phoenix_contact connector MCV_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-GF-5.08_1x12_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847712 8A 320V +phoenix_contact connector MCV_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-GF-5.08_1x12_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847712 8A 320V +phoenix_contact connector MCV_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-G-5.08_1x02_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-5.08; number of pins: 02; pin pitch: 5.08mm; Angled || order number: 1836189 8A 320V +phoenix_contact connector MC_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-GF-5.08_1x02_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847466 8A 320V +phoenix_contact connector MC_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-GF-5.08_1x02_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847466 8A 320V +phoenix_contact connector MC_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-G-5.08_1x03_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-5.08; number of pins: 03; pin pitch: 5.08mm; Angled || order number: 1836192 8A 320V +phoenix_contact connector MC_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-GF-5.08_1x03_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847479 8A 320V +phoenix_contact connector MC_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-GF-5.08_1x03_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847479 8A 320V +phoenix_contact connector MC_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-G-5.08_1x04_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-5.08; number of pins: 04; pin pitch: 5.08mm; Angled || order number: 1836202 8A 320V +phoenix_contact connector MC_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-GF-5.08_1x04_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847482 8A 320V +phoenix_contact connector MC_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-GF-5.08_1x04_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847482 8A 320V +phoenix_contact connector MC_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-G-5.08_1x05_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-5.08; number of pins: 05; pin pitch: 5.08mm; Angled || order number: 1836215 8A 320V +phoenix_contact connector MC_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-GF-5.08_1x05_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847495 8A 320V +phoenix_contact connector MC_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-GF-5.08_1x05_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847495 8A 320V +phoenix_contact connector MC_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-G-5.08_1x06_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-5.08; number of pins: 06; pin pitch: 5.08mm; Angled || order number: 1836228 8A 320V +phoenix_contact connector MC_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-GF-5.08_1x06_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847505 8A 320V +phoenix_contact connector MC_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-GF-5.08_1x06_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847505 8A 320V +phoenix_contact connector MC_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-G-5.08_1x07_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-5.08; number of pins: 07; pin pitch: 5.08mm; Angled || order number: 1836231 8A 320V +phoenix_contact connector MC_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-GF-5.08_1x07_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847518 8A 320V +phoenix_contact connector MC_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-GF-5.08_1x07_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847518 8A 320V +phoenix_contact connector MC_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-G-5.08_1x08_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-5.08; number of pins: 08; pin pitch: 5.08mm; Angled || order number: 1836244 8A 320V +phoenix_contact connector MC_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-GF-5.08_1x08_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847521 8A 320V +phoenix_contact connector MC_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-GF-5.08_1x08_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847521 8A 320V +phoenix_contact connector MC_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-G-5.08_1x09_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-5.08; number of pins: 09; pin pitch: 5.08mm; Angled || order number: 1836257 8A 320V +phoenix_contact connector MC_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-GF-5.08_1x09_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847534 8A 320V +phoenix_contact connector MC_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-GF-5.08_1x09_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847534 8A 320V +phoenix_contact connector MC_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-G-5.08_1x10_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-5.08; number of pins: 10; pin pitch: 5.08mm; Angled || order number: 1836260 8A 320V +phoenix_contact connector MC_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-GF-5.08_1x10_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847547 8A 320V +phoenix_contact connector MC_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-GF-5.08_1x10_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847547 8A 320V +phoenix_contact connector MC_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-G-5.08_1x11_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-5.08; number of pins: 11; pin pitch: 5.08mm; Angled || order number: 1836273 8A 320V +phoenix_contact connector MC_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-GF-5.08_1x11_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847550 8A 320V +phoenix_contact connector MC_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-GF-5.08_1x11_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847550 8A 320V +phoenix_contact connector MC_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-G-5.08_1x12_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-5.08; number of pins: 12; pin pitch: 5.08mm; Angled || order number: 1836286 8A 320V +phoenix_contact connector MC_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-GF-5.08_1x12_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847563 8A 320V +phoenix_contact connector MC_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-GF-5.08_1x12_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847563 8A 320V +phoenix_contact connector MC_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_2-G-5,08_1x02_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/2-G-5,08; number of pins: 02; pin pitch: 5.08mm; Angled || order number: 1757242 12A || order number: 1923869 16A (HC) +phoenix_contact connector MSTBA_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_2-G_1x02_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/2-G; number of pins: 02; pin pitch: 5.00mm; Angled || order number: 1757475 12A || order number: 1923759 16A (HC) +phoenix_contact connector MSTBA_01x02_G_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_3-G-5,08_1x03_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/3-G-5,08; number of pins: 03; pin pitch: 5.08mm; Angled || order number: 1757255 12A || order number: 1923872 16A (HC) +phoenix_contact connector MSTBA_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_3-G_1x03_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/3-G; number of pins: 03; pin pitch: 5.00mm; Angled || order number: 1757488 12A || order number: 1923762 16A (HC) +phoenix_contact connector MSTBA_01x03_G_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_4-G-5,08_1x04_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/4-G-5,08; number of pins: 04; pin pitch: 5.08mm; Angled || order number: 1757268 12A || order number: 1923885 16A (HC) +phoenix_contact connector MSTBA_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_4-G_1x04_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/4-G; number of pins: 04; pin pitch: 5.00mm; Angled || order number: 1757491 12A || order number: 1923775 16A (HC) +phoenix_contact connector MSTBA_01x04_G_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_5-G-5,08_1x05_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/5-G-5,08; number of pins: 05; pin pitch: 5.08mm; Angled || order number: 1757271 12A || order number: 1923898 16A (HC) +phoenix_contact connector MSTBA_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_5-G_1x05_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/5-G; number of pins: 05; pin pitch: 5.00mm; Angled || order number: 1757501 12A || order number: 1923788 16A (HC) +phoenix_contact connector MSTBA_01x05_G_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_6-G-5,08_1x06_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/6-G-5,08; number of pins: 06; pin pitch: 5.08mm; Angled || order number: 1757284 12A || order number: 1923908 16A (HC) +phoenix_contact connector MSTBA_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_6-G_1x06_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/6-G; number of pins: 06; pin pitch: 5.00mm; Angled || order number: 1757514 12A || order number: 1923791 16A (HC) +phoenix_contact connector MSTBA_01x06_G_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_7-G-5,08_1x07_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/7-G-5,08; number of pins: 07; pin pitch: 5.08mm; Angled || order number: 1757297 12A || order number: 1923911 16A (HC) +phoenix_contact connector MSTBA_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_7-G_1x07_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/7-G; number of pins: 07; pin pitch: 5.00mm; Angled || order number: 1757493 12A || order number: 1923801 16A (HC) +phoenix_contact connector MSTBA_01x07_G_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_8-G-5,08_1x08_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/8-G-5,08; number of pins: 08; pin pitch: 5.08mm; Angled || order number: 1757307 12A || order number: 1923924 16A (HC) +phoenix_contact connector MSTBA_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_8-G_1x08_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/8-G; number of pins: 08; pin pitch: 5.00mm; Angled || order number: 1757527 12A || order number: 1923814 16A (HC) +phoenix_contact connector MSTBA_01x08_G_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_9-G-5,08_1x09_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/9-G-5,08; number of pins: 09; pin pitch: 5.08mm; Angled || order number: 1757310 12A || order number: 1923937 16A (HC) +phoenix_contact connector MSTBA_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_9-G_1x09_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/9-G; number of pins: 09; pin pitch: 5.00mm; Angled || order number: 1757530 12A || order number: 1923827 16A (HC) +phoenix_contact connector MSTBA_01x09_G_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_10-G-5,08_1x10_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/10-G-5,08; number of pins: 10; pin pitch: 5.08mm; Angled || order number: 1757323 12A || order number: 1923940 16A (HC) +phoenix_contact connector MSTBA_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_10-G_1x10_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/10-G; number of pins: 10; pin pitch: 5.00mm; Angled || order number: 1757543 12A || order number: 1923830 16A (HC) +phoenix_contact connector MSTBA_01x10_G_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_11-G-5,08_1x11_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/11-G-5,08; number of pins: 11; pin pitch: 5.08mm; Angled || order number: 1757336 12A || order number: 1923953 16A (HC) +phoenix_contact connector MSTBA_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_11-G_1x11_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/11-G; number of pins: 11; pin pitch: 5.00mm; Angled || order number: 1757556 12A || order number: 1923843 16A (HC) +phoenix_contact connector MSTBA_01x11_G_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_12-G-5,08_1x12_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/12-G-5,08; number of pins: 12; pin pitch: 5.08mm; Angled || order number: 1757349 12A || order number: 1923966 16A (HC) +phoenix_contact connector MSTBA_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_12-G_1x12_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/12-G; number of pins: 12; pin pitch: 5.00mm; Angled || order number: 1757569 12A || order number: 1923856 16A (HC) +phoenix_contact connector MSTBA_01x12_G_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_13-G-5,08_1x13_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/13-G-5,08; number of pins: 13; pin pitch: 5.08mm; Angled || order number: 1757352 12A +phoenix_contact connector MSTBA_01x13_G_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_13-G_1x13_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/13-G; number of pins: 13; pin pitch: 5.00mm; Angled || order number: 1757572 12A +phoenix_contact connector MSTBA_01x13_G_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_14-G-5,08_1x14_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/14-G-5,08; number of pins: 14; pin pitch: 5.08mm; Angled || order number: 1757365 12A +phoenix_contact connector MSTBA_01x14_G_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_14-G_1x14_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/14-G; number of pins: 14; pin pitch: 5.00mm; Angled || order number: 1757585 12A +phoenix_contact connector MSTBA_01x14_G_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_15-G-5,08_1x15_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/15-G-5,08; number of pins: 15; pin pitch: 5.08mm; Angled || order number: 1757378 12A +phoenix_contact connector MSTBA_01x15_G_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_15-G_1x15_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/15-G; number of pins: 15; pin pitch: 5.00mm; Angled || order number: 1757598 12A +phoenix_contact connector MSTBA_01x15_G_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_16-G-5,08_1x16_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/16-G-5,08; number of pins: 16; pin pitch: 5.08mm; Angled || order number: 1757381 12A +phoenix_contact connector MSTBA_01x16_G_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBA_2,5_16-G_1x16_P5.00mm_Horizontal +Generic Phoenix Contact connector footprint for: MSTBA_2,5/16-G; number of pins: 16; pin pitch: 5.00mm; Angled || order number: 1757608 12A +phoenix_contact connector MSTBA_01x16_G_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_2-G-5,08_1x02_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/2-G-5,08; number of pins: 02; pin pitch: 5.08mm; Vertical || order number: 1755736 12A || order number: 1924305 16A (HC) +phoenix_contact connector MSTBVA_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_2-G_1x02_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/2-G; number of pins: 02; pin pitch: 5.00mm; Vertical || order number: 1755516 12A || order number: 1924198 16A (HC) +phoenix_contact connector MSTBVA_01x02_G_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_3-G-5,08_1x03_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/3-G-5,08; number of pins: 03; pin pitch: 5.08mm; Vertical || order number: 1755749 12A || order number: 1924318 16A (HC) +phoenix_contact connector MSTBVA_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_3-G_1x03_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/3-G; number of pins: 03; pin pitch: 5.00mm; Vertical || order number: 1755529 12A || order number: 1924208 16A (HC) +phoenix_contact connector MSTBVA_01x03_G_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_4-G-5,08_1x04_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/4-G-5,08; number of pins: 04; pin pitch: 5.08mm; Vertical || order number: 1755752 12A || order number: 1924321 16A (HC) +phoenix_contact connector MSTBVA_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_4-G_1x04_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/4-G; number of pins: 04; pin pitch: 5.00mm; Vertical || order number: 1755532 12A || order number: 1924211 16A (HC) +phoenix_contact connector MSTBVA_01x04_G_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_5-G-5,08_1x05_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/5-G-5,08; number of pins: 05; pin pitch: 5.08mm; Vertical || order number: 1755765 12A || order number: 1924334 16A (HC) +phoenix_contact connector MSTBVA_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_5-G_1x05_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/5-G; number of pins: 05; pin pitch: 5.00mm; Vertical || order number: 1755545 12A || order number: 1924224 16A (HC) +phoenix_contact connector MSTBVA_01x05_G_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_6-G-5,08_1x06_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/6-G-5,08; number of pins: 06; pin pitch: 5.08mm; Vertical || order number: 1755778 12A || order number: 1924347 16A (HC) +phoenix_contact connector MSTBVA_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_6-G_1x06_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/6-G; number of pins: 06; pin pitch: 5.00mm; Vertical || order number: 1755558 12A || order number: 1924237 16A (HC) +phoenix_contact connector MSTBVA_01x06_G_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_7-G-5,08_1x07_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/7-G-5,08; number of pins: 07; pin pitch: 5.08mm; Vertical || order number: 1755781 12A || order number: 1924350 16A (HC) +phoenix_contact connector MSTBVA_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_7-G_1x07_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/7-G; number of pins: 07; pin pitch: 5.00mm; Vertical || order number: 1755561 12A || order number: 1924240 16A (HC) +phoenix_contact connector MSTBVA_01x07_G_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_8-G-5,08_1x08_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/8-G-5,08; number of pins: 08; pin pitch: 5.08mm; Vertical || order number: 1755794 12A || order number: 1924363 16A (HC) +phoenix_contact connector MSTBVA_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_8-G_1x08_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/8-G; number of pins: 08; pin pitch: 5.00mm; Vertical || order number: 1755574 12A || order number: 1924253 16A (HC) +phoenix_contact connector MSTBVA_01x08_G_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_9-G-5,08_1x09_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/9-G-5,08; number of pins: 09; pin pitch: 5.08mm; Vertical || order number: 1755804 12A || order number: 1924376 16A (HC) +phoenix_contact connector MSTBVA_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_9-G_1x09_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/9-G; number of pins: 09; pin pitch: 5.00mm; Vertical || order number: 1755587 12A || order number: 1924266 16A (HC) +phoenix_contact connector MSTBVA_01x09_G_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_10-G-5,08_1x10_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/10-G-5,08; number of pins: 10; pin pitch: 5.08mm; Vertical || order number: 1755817 12A || order number: 1924389 16A (HC) +phoenix_contact connector MSTBVA_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_10-G_1x10_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/10-G; number of pins: 10; pin pitch: 5.00mm; Vertical || order number: 1755503 12A || order number: 1924279 16A (HC) +phoenix_contact connector MSTBVA_01x10_G_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_11-G-5,08_1x11_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/11-G-5,08; number of pins: 11; pin pitch: 5.08mm; Vertical || order number: 1755820 12A || order number: 1924392 16A (HC) +phoenix_contact connector MSTBVA_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_11-G_1x11_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/11-G; number of pins: 11; pin pitch: 5.00mm; Vertical || order number: 1755590 12A || order number: 1924282 16A (HC) +phoenix_contact connector MSTBVA_01x11_G_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_12-G-5,08_1x12_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/12-G-5,08; number of pins: 12; pin pitch: 5.08mm; Vertical || order number: 1755833 12A || order number: 1924402 16A (HC) +phoenix_contact connector MSTBVA_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_12-G_1x12_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/12-G; number of pins: 12; pin pitch: 5.00mm; Vertical || order number: 1755600 12A || order number: 1924295 16A (HC) +phoenix_contact connector MSTBVA_01x12_G_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_13-G-5,08_1x13_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/13-G-5,08; number of pins: 13; pin pitch: 5.08mm; Vertical || order number: 1755846 12A +phoenix_contact connector MSTBVA_01x13_G_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_13-G_1x13_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/13-G; number of pins: 13; pin pitch: 5.00mm; Vertical || order number: 1755613 12A +phoenix_contact connector MSTBVA_01x13_G_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_14-G-5,08_1x14_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/14-G-5,08; number of pins: 14; pin pitch: 5.08mm; Vertical || order number: 1755859 12A +phoenix_contact connector MSTBVA_01x14_G_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_14-G_1x14_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/14-G; number of pins: 14; pin pitch: 5.00mm; Vertical || order number: 1755626 12A +phoenix_contact connector MSTBVA_01x14_G_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_15-G-5,08_1x15_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/15-G-5,08; number of pins: 15; pin pitch: 5.08mm; Vertical || order number: 1755862 12A +phoenix_contact connector MSTBVA_01x15_G_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_15-G_1x15_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/15-G; number of pins: 15; pin pitch: 5.00mm; Vertical || order number: 1755639 12A +phoenix_contact connector MSTBVA_01x15_G_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_16-G-5,08_1x16_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/16-G-5,08; number of pins: 16; pin pitch: 5.08mm; Vertical || order number: 1755875 12A +phoenix_contact connector MSTBVA_01x16_G_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBVA_2,5_16-G_1x16_P5.00mm_Vertical +Generic Phoenix Contact connector footprint for: MSTBVA_2,5/16-G; number of pins: 16; pin pitch: 5.00mm; Vertical || order number: 1755642 12A +phoenix_contact connector MSTBVA_01x16_G_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF-5,08_1x02_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777073 12A || order number: 1924525 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF-5,08_1x02_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777073 12A || order number: 1924525 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF_1x02_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776883 12A || order number: 1924415 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_2-GF_1x02_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776883 12A || order number: 1924415 16A (HC) +phoenix_contact connector MSTBV_01x02_GF_5.00mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF-5,08_1x03_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777086 12A || order number: 1924538 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF-5,08_1x03_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777086 12A || order number: 1924538 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF_1x03_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776896 12A || order number: 1924428 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_3-GF_1x03_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776896 12A || order number: 1924428 16A (HC) +phoenix_contact connector MSTBV_01x03_GF_5.00mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF-5,08_1x04_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777099 12A || order number: 1924541 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF-5,08_1x04_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777099 12A || order number: 1924541 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF_1x04_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776906 12A || order number: 1924431 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_4-GF_1x04_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776906 12A || order number: 1924431 16A (HC) +phoenix_contact connector MSTBV_01x04_GF_5.00mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF-5,08_1x05_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777109 12A || order number: 1924554 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF-5,08_1x05_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777109 12A || order number: 1924554 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF_1x05_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776919 12A || order number: 1924444 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_5-GF_1x05_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776919 12A || order number: 1924444 16A (HC) +phoenix_contact connector MSTBV_01x05_GF_5.00mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF-5,08_1x06_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777112 12A || order number: 1924567 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF-5,08_1x06_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777112 12A || order number: 1924567 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF_1x06_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776922 12A || order number: 1924457 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_6-GF_1x06_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776922 12A || order number: 1924457 16A (HC) +phoenix_contact connector MSTBV_01x06_GF_5.00mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF-5,08_1x07_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777125 12A || order number: 1924570 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF-5,08_1x07_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777125 12A || order number: 1924570 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF_1x07_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776935 12A || order number: 1924460 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_7-GF_1x07_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776935 12A || order number: 1924460 16A (HC) +phoenix_contact connector MSTBV_01x07_GF_5.00mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF-5,08_1x08_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777138 12A || order number: 1924583 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF-5,08_1x08_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777138 12A || order number: 1924583 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF_1x08_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776948 12A || order number: 1924473 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_8-GF_1x08_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776948 12A || order number: 1924473 16A (HC) +phoenix_contact connector MSTBV_01x08_GF_5.00mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF-5,08_1x09_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777141 12A || order number: 1924596 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF-5,08_1x09_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777141 12A || order number: 1924596 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF_1x09_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776951 12A || order number: 1924486 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_9-GF_1x09_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776951 12A || order number: 1924486 16A (HC) +phoenix_contact connector MSTBV_01x09_GF_5.00mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF-5,08_1x10_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777154 12A || order number: 1924606 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF-5,08_1x10_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777154 12A || order number: 1924606 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF_1x10_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776964 12A || order number: 1924499 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_10-GF_1x10_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776964 12A || order number: 1924499 16A (HC) +phoenix_contact connector MSTBV_01x10_GF_5.00mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF-5,08_1x11_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777167 12A || order number: 1924619 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF-5,08_1x11_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777167 12A || order number: 1924619 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF_1x11_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776977 12A || order number: 1924509 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_11-GF_1x11_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776977 12A || order number: 1924509 16A (HC) +phoenix_contact connector MSTBV_01x11_GF_5.00mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF-5,08_1x12_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777170 12A || order number: 1924622 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF-5,08_1x12_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777170 12A || order number: 1924622 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF_1x12_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776980 12A || order number: 1924512 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_12-GF_1x12_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776980 12A || order number: 1924512 16A (HC) +phoenix_contact connector MSTBV_01x12_GF_5.00mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF-5,08_1x13_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777183 12A +phoenix_contact connector MSTBV_01x13_GF_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF-5,08_1x13_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777183 12A +phoenix_contact connector MSTBV_01x13_GF_5.08mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF_1x13_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776993 12A +phoenix_contact connector MSTBV_01x13_GF_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_13-GF_1x13_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776993 12A +phoenix_contact connector MSTBV_01x13_GF_5.00mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF-5,08_1x14_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777196 12A +phoenix_contact connector MSTBV_01x14_GF_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF-5,08_1x14_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777196 12A +phoenix_contact connector MSTBV_01x14_GF_5.08mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF_1x14_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776002 12A +phoenix_contact connector MSTBV_01x14_GF_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_14-GF_1x14_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776002 12A +phoenix_contact connector MSTBV_01x14_GF_5.00mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF-5,08_1x15_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777206 12A +phoenix_contact connector MSTBV_01x15_GF_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF-5,08_1x15_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777206 12A +phoenix_contact connector MSTBV_01x15_GF_5.08mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF_1x15_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776015 12A +phoenix_contact connector MSTBV_01x15_GF_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_15-GF_1x15_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776015 12A +phoenix_contact connector MSTBV_01x15_GF_5.00mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF-5,08_1x16_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1777219 12A +phoenix_contact connector MSTBV_01x16_GF_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF-5,08_1x16_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1777219 12A +phoenix_contact connector MSTBV_01x16_GF_5.08mm_MH +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF_1x16_P5.00mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Vertical; threaded flange || order number: 1776028 12A +phoenix_contact connector MSTBV_01x16_GF_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTBV_2,5_16-GF_1x16_P5.00mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTBV_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776028 12A +phoenix_contact connector MSTBV_01x16_GF_5.00mm_MH +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF-5,08_1x02_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776508 12A || order number: 1924088 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF-5,08_1x02_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF-5,08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776508 12A || order number: 1924088 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF_1x02_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776692 12A || order number: 1923979 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.00mm +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_2-GF_1x02_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/2-GF; number of pins: 02; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776692 12A || order number: 1923979 16A (HC) +phoenix_contact connector MSTB_01x02_GF_5.00mm_MH +0 +2 +2 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF-5,08_1x03_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776511 12A || order number: 1924091 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF-5,08_1x03_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF-5,08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776511 12A || order number: 1924091 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF_1x03_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776702 12A || order number: 1923982 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.00mm +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_3-GF_1x03_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/3-GF; number of pins: 03; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776702 12A || order number: 1923982 16A (HC) +phoenix_contact connector MSTB_01x03_GF_5.00mm_MH +0 +3 +3 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF-5,08_1x04_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776524 12A || order number: 1924101 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF-5,08_1x04_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF-5,08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776524 12A || order number: 1924101 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF_1x04_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776715 12A || order number: 1923995 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.00mm +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_4-GF_1x04_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/4-GF; number of pins: 04; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776715 12A || order number: 1923995 16A (HC) +phoenix_contact connector MSTB_01x04_GF_5.00mm_MH +0 +4 +4 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF-5,08_1x05_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776537 12A || order number: 1924114 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF-5,08_1x05_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF-5,08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776537 12A || order number: 1924114 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF_1x05_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776728 12A || order number: 1924004 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.00mm +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_5-GF_1x05_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/5-GF; number of pins: 05; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776728 12A || order number: 1924004 16A (HC) +phoenix_contact connector MSTB_01x05_GF_5.00mm_MH +0 +5 +5 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF-5,08_1x06_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776540 12A || order number: 1924127 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF-5,08_1x06_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF-5,08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776540 12A || order number: 1924127 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF_1x06_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776731 12A || order number: 1924017 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.00mm +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_6-GF_1x06_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/6-GF; number of pins: 06; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776731 12A || order number: 1924017 16A (HC) +phoenix_contact connector MSTB_01x06_GF_5.00mm_MH +0 +6 +6 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF-5,08_1x07_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776553 12A || order number: 1924130 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF-5,08_1x07_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF-5,08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776553 12A || order number: 1924130 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF_1x07_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776744 12A || order number: 1924020 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.00mm +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_7-GF_1x07_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/7-GF; number of pins: 07; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776744 12A || order number: 1924020 16A (HC) +phoenix_contact connector MSTB_01x07_GF_5.00mm_MH +0 +7 +7 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF-5,08_1x08_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776566 12A || order number: 1924143 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF-5,08_1x08_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF-5,08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776566 12A || order number: 1924143 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF_1x08_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776757 12A || order number: 1924033 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.00mm +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_8-GF_1x08_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/8-GF; number of pins: 08; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776757 12A || order number: 1924033 16A (HC) +phoenix_contact connector MSTB_01x08_GF_5.00mm_MH +0 +8 +8 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF-5,08_1x09_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776579 12A || order number: 1924156 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF-5,08_1x09_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF-5,08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776579 12A || order number: 1924156 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF_1x09_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776760 12A || order number: 1924046 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.00mm +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_9-GF_1x09_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/9-GF; number of pins: 09; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776760 12A || order number: 1924046 16A (HC) +phoenix_contact connector MSTB_01x09_GF_5.00mm_MH +0 +9 +9 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF-5,08_1x10_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776582 12A || order number: 1924169 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF-5,08_1x10_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF-5,08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776582 12A || order number: 1924169 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF_1x10_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776773 12A || order number: 1924059 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.00mm +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_10-GF_1x10_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/10-GF; number of pins: 10; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776773 12A || order number: 1924059 16A (HC) +phoenix_contact connector MSTB_01x10_GF_5.00mm_MH +0 +10 +10 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF-5,08_1x11_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776595 12A || order number: 1924172 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF-5,08_1x11_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF-5,08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776595 12A || order number: 1924172 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF_1x11_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776786 12A || order number: 1924062 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.00mm +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_11-GF_1x11_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/11-GF; number of pins: 11; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776786 12A || order number: 1924062 16A (HC) +phoenix_contact connector MSTB_01x11_GF_5.00mm_MH +0 +11 +11 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF-5,08_1x12_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776605 12A || order number: 1924185 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF-5,08_1x12_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF-5,08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776605 12A || order number: 1924185 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF_1x12_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776799 12A || order number: 1924075 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.00mm +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_12-GF_1x12_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/12-GF; number of pins: 12; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776799 12A || order number: 1924075 16A (HC) +phoenix_contact connector MSTB_01x12_GF_5.00mm_MH +0 +12 +12 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF-5,08_1x13_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776618 12A +phoenix_contact connector MSTB_01x13_GF_5.08mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF-5,08_1x13_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF-5,08; number of pins: 13; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776618 12A +phoenix_contact connector MSTB_01x13_GF_5.08mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF_1x13_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776809 12A +phoenix_contact connector MSTB_01x13_GF_5.00mm +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_13-GF_1x13_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/13-GF; number of pins: 13; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776809 12A +phoenix_contact connector MSTB_01x13_GF_5.00mm_MH +0 +13 +13 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF-5,08_1x14_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776621 12A +phoenix_contact connector MSTB_01x14_GF_5.08mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF-5,08_1x14_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF-5,08; number of pins: 14; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776621 12A +phoenix_contact connector MSTB_01x14_GF_5.08mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF_1x14_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776812 12A +phoenix_contact connector MSTB_01x14_GF_5.00mm +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_14-GF_1x14_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/14-GF; number of pins: 14; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776812 12A +phoenix_contact connector MSTB_01x14_GF_5.00mm_MH +0 +14 +14 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF-5,08_1x15_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776634 12A +phoenix_contact connector MSTB_01x15_GF_5.08mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF-5,08_1x15_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF-5,08; number of pins: 15; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776634 12A +phoenix_contact connector MSTB_01x15_GF_5.08mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF_1x15_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776825 12A +phoenix_contact connector MSTB_01x15_GF_5.00mm +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_15-GF_1x15_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/15-GF; number of pins: 15; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776825 12A +phoenix_contact connector MSTB_01x15_GF_5.00mm_MH +0 +15 +15 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF-5,08_1x16_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Angled; threaded flange || order number: 1776647 12A +phoenix_contact connector MSTB_01x16_GF_5.08mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF-5,08_1x16_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF-5,08; number of pins: 16; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776647 12A +phoenix_contact connector MSTB_01x16_GF_5.08mm_MH +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF_1x16_P5.00mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Angled; threaded flange || order number: 1776838 12A +phoenix_contact connector MSTB_01x16_GF_5.00mm +0 +16 +16 +Connector_Phoenix_MSTB +PhoenixContact_MSTB_2,5_16-GF_1x16_P5.00mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MSTB_2,5/16-GF; number of pins: 16; pin pitch: 5.00mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1776838 12A +phoenix_contact connector MSTB_01x16_GF_5.00mm_MH +0 +16 +16 +Connector_Pin +Pin_D0.7mm_L6.5mm_W1.8mm_FlatFork +solder Pin_ with flat fork, hole diameter 0.7mm, length 6.5mm, width 1.8mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D0.9mm_L10.0mm_W2.4mm_FlatFork +solder Pin_ with flat fork, hole diameter 0.9mm, length 10.0mm, width 2.4mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.0mm_L10.0mm +solder Pin_ diameter 1.0mm, hole diameter 1.0mm (press fit), length 10.0mm +solder Pin_ press fit +0 +1 +1 +Connector_Pin +Pin_D1.0mm_L10.0mm_LooseFit +solder Pin_ diameter 1.0mm, hole diameter 1.2mm (loose fit), length 10.0mm +solder Pin_ loose fit +0 +1 +1 +Connector_Pin +Pin_D1.1mm_L8.5mm_W2.5mm_FlatFork +solder Pin_ with flat fork, hole diameter 1.1mm, length 8.5mm, width 2.5mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.1mm_L10.2mm_W3.5mm_Flat +solder Pin_ with flat with hole, hole diameter 1.1mm, length 10.2mm, width 3.5mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.2mm_L10.2mm_W2.9mm_FlatFork +solder Pin_ with flat with fork, hole diameter 1.2mm, length 11.3mm, width 3.0mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.2mm_L11.3mm_W3.0mm_Flat +solder Pin_ with flat with hole, hole diameter 1.2mm, length 11.3mm, width 3.0mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L10.0mm_W3.5mm_Flat +solder Pin_ with flat with hole, hole diameter 1.3mm, length 10.0mm, width 3.5mm, e.g. Ettinger 13.13.865, https://katalog.ettinger.de/#p=434 +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.0mm +solder Pin_ diameter 1.3mm, hole diameter 1.3mm, length 11.0mm +solder Pin_ pressfit +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.0mm_LooseFit +solder Pin_ diameter 1.3mm, hole diameter 1.5mm (loose fit), length 11.0mm +solder Pin_ loose fit +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.3mm_W2.8mm_Flat +solder Pin_ with flat with hole, hole diameter 1.3mm, length 11.3mm, width 2.8mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.4mm_L8.5mm_W2.8mm_FlatFork +solder Pin_ with flat with fork, hole diameter 1.4mm, length 8.5mm, width 2.8mm, e.g. Ettinger 13.13.890, https://katalog.ettinger.de/#p=434 +solder Pin_ with flat fork +0 +1 +1 +Connector_PinHeader_1.00mm +PinHeader_1x01_P1.00mm_Horizontal +Through hole angled pin header, 1x01, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x01 1.00mm single row +0 +1 +1 +Connector_PinHeader_1.00mm +PinHeader_1x01_P1.00mm_Vertical +Through hole straight pin header, 1x01, 1.00mm pitch, single row +Through hole pin header THT 1x01 1.00mm single row +0 +1 +1 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Horizontal +Through hole angled pin header, 1x02, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Vertical +Through hole straight pin header, 1x02, 1.00mm pitch, single row +Through hole pin header THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 1.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x02_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 1.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Horizontal +Through hole angled pin header, 1x03, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Vertical +Through hole straight pin header, 1x03, 1.00mm pitch, single row +Through hole pin header THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 1.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x03_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 1.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Horizontal +Through hole angled pin header, 1x04, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Vertical +Through hole straight pin header, 1x04, 1.00mm pitch, single row +Through hole pin header THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 1.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x04_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 1.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Horizontal +Through hole angled pin header, 1x05, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Vertical +Through hole straight pin header, 1x05, 1.00mm pitch, single row +Through hole pin header THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 1.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x05_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 1.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Horizontal +Through hole angled pin header, 1x06, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Vertical +Through hole straight pin header, 1x06, 1.00mm pitch, single row +Through hole pin header THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 1.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x06_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 1.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Horizontal +Through hole angled pin header, 1x07, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Vertical +Through hole straight pin header, 1x07, 1.00mm pitch, single row +Through hole pin header THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 1.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x07_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 1.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Horizontal +Through hole angled pin header, 1x08, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Vertical +Through hole straight pin header, 1x08, 1.00mm pitch, single row +Through hole pin header THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 1.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x08_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 1.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Horizontal +Through hole angled pin header, 1x09, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Vertical +Through hole straight pin header, 1x09, 1.00mm pitch, single row +Through hole pin header THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 1.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x09_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 1.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Horizontal +Through hole angled pin header, 1x10, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Vertical +Through hole straight pin header, 1x10, 1.00mm pitch, single row +Through hole pin header THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 1.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x10_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 1.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Horizontal +Through hole angled pin header, 1x11, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Vertical +Through hole straight pin header, 1x11, 1.00mm pitch, single row +Through hole pin header THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 1.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x11_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 1.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Horizontal +Through hole angled pin header, 1x12, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Vertical +Through hole straight pin header, 1x12, 1.00mm pitch, single row +Through hole pin header THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 1.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x12_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 1.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Horizontal +Through hole angled pin header, 1x13, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Vertical +Through hole straight pin header, 1x13, 1.00mm pitch, single row +Through hole pin header THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 1.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x13_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 1.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Horizontal +Through hole angled pin header, 1x14, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Vertical +Through hole straight pin header, 1x14, 1.00mm pitch, single row +Through hole pin header THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 1.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x14_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 1.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Horizontal +Through hole angled pin header, 1x15, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Vertical +Through hole straight pin header, 1x15, 1.00mm pitch, single row +Through hole pin header THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 1.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x15_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 1.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Horizontal +Through hole angled pin header, 1x16, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Vertical +Through hole straight pin header, 1x16, 1.00mm pitch, single row +Through hole pin header THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 1.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x16_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 1.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Horizontal +Through hole angled pin header, 1x17, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Vertical +Through hole straight pin header, 1x17, 1.00mm pitch, single row +Through hole pin header THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 1.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x17_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 1.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Horizontal +Through hole angled pin header, 1x18, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Vertical +Through hole straight pin header, 1x18, 1.00mm pitch, single row +Through hole pin header THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 1.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x18_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 1.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Horizontal +Through hole angled pin header, 1x19, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Vertical +Through hole straight pin header, 1x19, 1.00mm pitch, single row +Through hole pin header THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 1.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x19_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 1.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Horizontal +Through hole angled pin header, 1x20, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Vertical +Through hole straight pin header, 1x20, 1.00mm pitch, single row +Through hole pin header THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 1.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x20_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 1.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Horizontal +Through hole angled pin header, 1x21, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Vertical +Through hole straight pin header, 1x21, 1.00mm pitch, single row +Through hole pin header THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 1.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x21_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 1.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Horizontal +Through hole angled pin header, 1x22, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Vertical +Through hole straight pin header, 1x22, 1.00mm pitch, single row +Through hole pin header THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 1.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x22_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 1.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Horizontal +Through hole angled pin header, 1x23, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Vertical +Through hole straight pin header, 1x23, 1.00mm pitch, single row +Through hole pin header THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 1.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x23_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 1.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Horizontal +Through hole angled pin header, 1x24, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Vertical +Through hole straight pin header, 1x24, 1.00mm pitch, single row +Through hole pin header THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 1.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x24_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 1.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Horizontal +Through hole angled pin header, 1x25, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Vertical +Through hole straight pin header, 1x25, 1.00mm pitch, single row +Through hole pin header THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 1.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x25_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 1.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Horizontal +Through hole angled pin header, 1x26, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Vertical +Through hole straight pin header, 1x26, 1.00mm pitch, single row +Through hole pin header THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 1.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x26_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 1.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Horizontal +Through hole angled pin header, 1x27, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Vertical +Through hole straight pin header, 1x27, 1.00mm pitch, single row +Through hole pin header THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 1.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x27_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 1.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Horizontal +Through hole angled pin header, 1x28, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Vertical +Through hole straight pin header, 1x28, 1.00mm pitch, single row +Through hole pin header THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 1.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x28_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 1.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Horizontal +Through hole angled pin header, 1x29, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Vertical +Through hole straight pin header, 1x29, 1.00mm pitch, single row +Through hole pin header THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 1.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x29_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 1.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Horizontal +Through hole angled pin header, 1x30, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Vertical +Through hole straight pin header, 1x30, 1.00mm pitch, single row +Through hole pin header THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 1.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x30_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 1.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Horizontal +Through hole angled pin header, 1x31, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Vertical +Through hole straight pin header, 1x31, 1.00mm pitch, single row +Through hole pin header THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 1.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x31_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 1.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Horizontal +Through hole angled pin header, 1x32, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Vertical +Through hole straight pin header, 1x32, 1.00mm pitch, single row +Through hole pin header THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 1.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x32_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 1.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Horizontal +Through hole angled pin header, 1x33, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Vertical +Through hole straight pin header, 1x33, 1.00mm pitch, single row +Through hole pin header THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 1.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x33_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 1.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Horizontal +Through hole angled pin header, 1x34, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Vertical +Through hole straight pin header, 1x34, 1.00mm pitch, single row +Through hole pin header THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 1.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x34_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 1.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Horizontal +Through hole angled pin header, 1x35, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Vertical +Through hole straight pin header, 1x35, 1.00mm pitch, single row +Through hole pin header THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 1.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x35_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 1.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Horizontal +Through hole angled pin header, 1x36, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Vertical +Through hole straight pin header, 1x36, 1.00mm pitch, single row +Through hole pin header THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 1.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x36_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 1.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Horizontal +Through hole angled pin header, 1x37, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Vertical +Through hole straight pin header, 1x37, 1.00mm pitch, single row +Through hole pin header THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 1.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x37_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 1.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Horizontal +Through hole angled pin header, 1x38, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Vertical +Through hole straight pin header, 1x38, 1.00mm pitch, single row +Through hole pin header THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 1.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x38_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 1.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Horizontal +Through hole angled pin header, 1x39, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Vertical +Through hole straight pin header, 1x39, 1.00mm pitch, single row +Through hole pin header THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 1.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x39_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 1.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Horizontal +Through hole angled pin header, 1x40, 1.00mm pitch, 2.0mm pin length, single row +Through hole angled pin header THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Vertical +Through hole straight pin header, 1x40, 1.00mm pitch, single row +Through hole pin header THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 1.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 1.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_1x40_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 1.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 1.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x01_P1.00mm_Horizontal +Through hole angled pin header, 2x01, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x01 1.00mm double row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_2x01_P1.00mm_Vertical +Through hole straight pin header, 2x01, 1.00mm pitch, double rows +Through hole pin header THT 2x01 1.00mm double row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_2x01_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x01 1.00mm double row +0 +2 +2 +Connector_PinHeader_1.00mm +PinHeader_2x02_P1.00mm_Horizontal +Through hole angled pin header, 2x02, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x02 1.00mm double row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_2x02_P1.00mm_Vertical +Through hole straight pin header, 2x02, 1.00mm pitch, double rows +Through hole pin header THT 2x02 1.00mm double row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_2x02_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x02 1.00mm double row +0 +4 +4 +Connector_PinHeader_1.00mm +PinHeader_2x03_P1.00mm_Horizontal +Through hole angled pin header, 2x03, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x03 1.00mm double row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_2x03_P1.00mm_Vertical +Through hole straight pin header, 2x03, 1.00mm pitch, double rows +Through hole pin header THT 2x03 1.00mm double row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_2x03_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x03 1.00mm double row +0 +6 +6 +Connector_PinHeader_1.00mm +PinHeader_2x04_P1.00mm_Horizontal +Through hole angled pin header, 2x04, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x04 1.00mm double row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_2x04_P1.00mm_Vertical +Through hole straight pin header, 2x04, 1.00mm pitch, double rows +Through hole pin header THT 2x04 1.00mm double row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_2x04_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x04 1.00mm double row +0 +8 +8 +Connector_PinHeader_1.00mm +PinHeader_2x05_P1.00mm_Horizontal +Through hole angled pin header, 2x05, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x05 1.00mm double row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_2x05_P1.00mm_Vertical +Through hole straight pin header, 2x05, 1.00mm pitch, double rows +Through hole pin header THT 2x05 1.00mm double row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_2x05_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x05 1.00mm double row +0 +10 +10 +Connector_PinHeader_1.00mm +PinHeader_2x06_P1.00mm_Horizontal +Through hole angled pin header, 2x06, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x06 1.00mm double row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_2x06_P1.00mm_Vertical +Through hole straight pin header, 2x06, 1.00mm pitch, double rows +Through hole pin header THT 2x06 1.00mm double row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_2x06_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x06 1.00mm double row +0 +12 +12 +Connector_PinHeader_1.00mm +PinHeader_2x07_P1.00mm_Horizontal +Through hole angled pin header, 2x07, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x07 1.00mm double row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_2x07_P1.00mm_Vertical +Through hole straight pin header, 2x07, 1.00mm pitch, double rows +Through hole pin header THT 2x07 1.00mm double row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_2x07_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x07 1.00mm double row +0 +14 +14 +Connector_PinHeader_1.00mm +PinHeader_2x08_P1.00mm_Horizontal +Through hole angled pin header, 2x08, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x08 1.00mm double row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_2x08_P1.00mm_Vertical +Through hole straight pin header, 2x08, 1.00mm pitch, double rows +Through hole pin header THT 2x08 1.00mm double row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_2x08_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x08 1.00mm double row +0 +16 +16 +Connector_PinHeader_1.00mm +PinHeader_2x09_P1.00mm_Horizontal +Through hole angled pin header, 2x09, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x09 1.00mm double row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_2x09_P1.00mm_Vertical +Through hole straight pin header, 2x09, 1.00mm pitch, double rows +Through hole pin header THT 2x09 1.00mm double row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_2x09_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x09 1.00mm double row +0 +18 +18 +Connector_PinHeader_1.00mm +PinHeader_2x10_P1.00mm_Horizontal +Through hole angled pin header, 2x10, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x10 1.00mm double row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_2x10_P1.00mm_Vertical +Through hole straight pin header, 2x10, 1.00mm pitch, double rows +Through hole pin header THT 2x10 1.00mm double row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_2x10_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x10 1.00mm double row +0 +20 +20 +Connector_PinHeader_1.00mm +PinHeader_2x11_P1.00mm_Horizontal +Through hole angled pin header, 2x11, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x11 1.00mm double row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_2x11_P1.00mm_Vertical +Through hole straight pin header, 2x11, 1.00mm pitch, double rows +Through hole pin header THT 2x11 1.00mm double row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_2x11_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x11 1.00mm double row +0 +22 +22 +Connector_PinHeader_1.00mm +PinHeader_2x12_P1.00mm_Horizontal +Through hole angled pin header, 2x12, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x12 1.00mm double row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_2x12_P1.00mm_Vertical +Through hole straight pin header, 2x12, 1.00mm pitch, double rows +Through hole pin header THT 2x12 1.00mm double row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_2x12_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x12 1.00mm double row +0 +24 +24 +Connector_PinHeader_1.00mm +PinHeader_2x13_P1.00mm_Horizontal +Through hole angled pin header, 2x13, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x13 1.00mm double row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_2x13_P1.00mm_Vertical +Through hole straight pin header, 2x13, 1.00mm pitch, double rows +Through hole pin header THT 2x13 1.00mm double row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_2x13_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x13 1.00mm double row +0 +26 +26 +Connector_PinHeader_1.00mm +PinHeader_2x14_P1.00mm_Horizontal +Through hole angled pin header, 2x14, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x14 1.00mm double row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_2x14_P1.00mm_Vertical +Through hole straight pin header, 2x14, 1.00mm pitch, double rows +Through hole pin header THT 2x14 1.00mm double row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_2x14_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x14 1.00mm double row +0 +28 +28 +Connector_PinHeader_1.00mm +PinHeader_2x15_P1.00mm_Horizontal +Through hole angled pin header, 2x15, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x15 1.00mm double row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_2x15_P1.00mm_Vertical +Through hole straight pin header, 2x15, 1.00mm pitch, double rows +Through hole pin header THT 2x15 1.00mm double row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_2x15_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x15 1.00mm double row +0 +30 +30 +Connector_PinHeader_1.00mm +PinHeader_2x16_P1.00mm_Horizontal +Through hole angled pin header, 2x16, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x16 1.00mm double row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_2x16_P1.00mm_Vertical +Through hole straight pin header, 2x16, 1.00mm pitch, double rows +Through hole pin header THT 2x16 1.00mm double row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_2x16_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x16 1.00mm double row +0 +32 +32 +Connector_PinHeader_1.00mm +PinHeader_2x17_P1.00mm_Horizontal +Through hole angled pin header, 2x17, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x17 1.00mm double row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_2x17_P1.00mm_Vertical +Through hole straight pin header, 2x17, 1.00mm pitch, double rows +Through hole pin header THT 2x17 1.00mm double row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_2x17_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x17 1.00mm double row +0 +34 +34 +Connector_PinHeader_1.00mm +PinHeader_2x18_P1.00mm_Horizontal +Through hole angled pin header, 2x18, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x18 1.00mm double row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_2x18_P1.00mm_Vertical +Through hole straight pin header, 2x18, 1.00mm pitch, double rows +Through hole pin header THT 2x18 1.00mm double row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_2x18_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x18 1.00mm double row +0 +36 +36 +Connector_PinHeader_1.00mm +PinHeader_2x19_P1.00mm_Horizontal +Through hole angled pin header, 2x19, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x19 1.00mm double row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_2x19_P1.00mm_Vertical +Through hole straight pin header, 2x19, 1.00mm pitch, double rows +Through hole pin header THT 2x19 1.00mm double row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_2x19_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x19 1.00mm double row +0 +38 +38 +Connector_PinHeader_1.00mm +PinHeader_2x20_P1.00mm_Horizontal +Through hole angled pin header, 2x20, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x20 1.00mm double row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x20_P1.00mm_Vertical +Through hole straight pin header, 2x20, 1.00mm pitch, double rows +Through hole pin header THT 2x20 1.00mm double row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x20_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x20 1.00mm double row +0 +40 +40 +Connector_PinHeader_1.00mm +PinHeader_2x21_P1.00mm_Horizontal +Through hole angled pin header, 2x21, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x21 1.00mm double row +0 +42 +42 +Connector_PinHeader_1.00mm +PinHeader_2x21_P1.00mm_Vertical +Through hole straight pin header, 2x21, 1.00mm pitch, double rows +Through hole pin header THT 2x21 1.00mm double row +0 +42 +42 +Connector_PinHeader_1.00mm +PinHeader_2x21_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x21 1.00mm double row +0 +42 +42 +Connector_PinHeader_1.00mm +PinHeader_2x22_P1.00mm_Horizontal +Through hole angled pin header, 2x22, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x22 1.00mm double row +0 +44 +44 +Connector_PinHeader_1.00mm +PinHeader_2x22_P1.00mm_Vertical +Through hole straight pin header, 2x22, 1.00mm pitch, double rows +Through hole pin header THT 2x22 1.00mm double row +0 +44 +44 +Connector_PinHeader_1.00mm +PinHeader_2x22_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x22 1.00mm double row +0 +44 +44 +Connector_PinHeader_1.00mm +PinHeader_2x23_P1.00mm_Horizontal +Through hole angled pin header, 2x23, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x23 1.00mm double row +0 +46 +46 +Connector_PinHeader_1.00mm +PinHeader_2x23_P1.00mm_Vertical +Through hole straight pin header, 2x23, 1.00mm pitch, double rows +Through hole pin header THT 2x23 1.00mm double row +0 +46 +46 +Connector_PinHeader_1.00mm +PinHeader_2x23_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x23 1.00mm double row +0 +46 +46 +Connector_PinHeader_1.00mm +PinHeader_2x24_P1.00mm_Horizontal +Through hole angled pin header, 2x24, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x24 1.00mm double row +0 +48 +48 +Connector_PinHeader_1.00mm +PinHeader_2x24_P1.00mm_Vertical +Through hole straight pin header, 2x24, 1.00mm pitch, double rows +Through hole pin header THT 2x24 1.00mm double row +0 +48 +48 +Connector_PinHeader_1.00mm +PinHeader_2x24_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x24 1.00mm double row +0 +48 +48 +Connector_PinHeader_1.00mm +PinHeader_2x25_P1.00mm_Horizontal +Through hole angled pin header, 2x25, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x25 1.00mm double row +0 +50 +50 +Connector_PinHeader_1.00mm +PinHeader_2x25_P1.00mm_Vertical +Through hole straight pin header, 2x25, 1.00mm pitch, double rows +Through hole pin header THT 2x25 1.00mm double row +0 +50 +50 +Connector_PinHeader_1.00mm +PinHeader_2x25_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x25 1.00mm double row +0 +50 +50 +Connector_PinHeader_1.00mm +PinHeader_2x26_P1.00mm_Horizontal +Through hole angled pin header, 2x26, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x26 1.00mm double row +0 +52 +52 +Connector_PinHeader_1.00mm +PinHeader_2x26_P1.00mm_Vertical +Through hole straight pin header, 2x26, 1.00mm pitch, double rows +Through hole pin header THT 2x26 1.00mm double row +0 +52 +52 +Connector_PinHeader_1.00mm +PinHeader_2x26_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x26 1.00mm double row +0 +52 +52 +Connector_PinHeader_1.00mm +PinHeader_2x27_P1.00mm_Horizontal +Through hole angled pin header, 2x27, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x27 1.00mm double row +0 +54 +54 +Connector_PinHeader_1.00mm +PinHeader_2x27_P1.00mm_Vertical +Through hole straight pin header, 2x27, 1.00mm pitch, double rows +Through hole pin header THT 2x27 1.00mm double row +0 +54 +54 +Connector_PinHeader_1.00mm +PinHeader_2x27_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x27 1.00mm double row +0 +54 +54 +Connector_PinHeader_1.00mm +PinHeader_2x28_P1.00mm_Horizontal +Through hole angled pin header, 2x28, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x28 1.00mm double row +0 +56 +56 +Connector_PinHeader_1.00mm +PinHeader_2x28_P1.00mm_Vertical +Through hole straight pin header, 2x28, 1.00mm pitch, double rows +Through hole pin header THT 2x28 1.00mm double row +0 +56 +56 +Connector_PinHeader_1.00mm +PinHeader_2x28_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x28 1.00mm double row +0 +56 +56 +Connector_PinHeader_1.00mm +PinHeader_2x29_P1.00mm_Horizontal +Through hole angled pin header, 2x29, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x29 1.00mm double row +0 +58 +58 +Connector_PinHeader_1.00mm +PinHeader_2x29_P1.00mm_Vertical +Through hole straight pin header, 2x29, 1.00mm pitch, double rows +Through hole pin header THT 2x29 1.00mm double row +0 +58 +58 +Connector_PinHeader_1.00mm +PinHeader_2x29_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x29 1.00mm double row +0 +58 +58 +Connector_PinHeader_1.00mm +PinHeader_2x30_P1.00mm_Horizontal +Through hole angled pin header, 2x30, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x30 1.00mm double row +0 +60 +60 +Connector_PinHeader_1.00mm +PinHeader_2x30_P1.00mm_Vertical +Through hole straight pin header, 2x30, 1.00mm pitch, double rows +Through hole pin header THT 2x30 1.00mm double row +0 +60 +60 +Connector_PinHeader_1.00mm +PinHeader_2x30_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x30 1.00mm double row +0 +60 +60 +Connector_PinHeader_1.00mm +PinHeader_2x31_P1.00mm_Horizontal +Through hole angled pin header, 2x31, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x31 1.00mm double row +0 +62 +62 +Connector_PinHeader_1.00mm +PinHeader_2x31_P1.00mm_Vertical +Through hole straight pin header, 2x31, 1.00mm pitch, double rows +Through hole pin header THT 2x31 1.00mm double row +0 +62 +62 +Connector_PinHeader_1.00mm +PinHeader_2x31_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x31 1.00mm double row +0 +62 +62 +Connector_PinHeader_1.00mm +PinHeader_2x32_P1.00mm_Horizontal +Through hole angled pin header, 2x32, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x32 1.00mm double row +0 +64 +64 +Connector_PinHeader_1.00mm +PinHeader_2x32_P1.00mm_Vertical +Through hole straight pin header, 2x32, 1.00mm pitch, double rows +Through hole pin header THT 2x32 1.00mm double row +0 +64 +64 +Connector_PinHeader_1.00mm +PinHeader_2x32_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x32 1.00mm double row +0 +64 +64 +Connector_PinHeader_1.00mm +PinHeader_2x33_P1.00mm_Horizontal +Through hole angled pin header, 2x33, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x33 1.00mm double row +0 +66 +66 +Connector_PinHeader_1.00mm +PinHeader_2x33_P1.00mm_Vertical +Through hole straight pin header, 2x33, 1.00mm pitch, double rows +Through hole pin header THT 2x33 1.00mm double row +0 +66 +66 +Connector_PinHeader_1.00mm +PinHeader_2x33_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x33 1.00mm double row +0 +66 +66 +Connector_PinHeader_1.00mm +PinHeader_2x34_P1.00mm_Horizontal +Through hole angled pin header, 2x34, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x34 1.00mm double row +0 +68 +68 +Connector_PinHeader_1.00mm +PinHeader_2x34_P1.00mm_Vertical +Through hole straight pin header, 2x34, 1.00mm pitch, double rows +Through hole pin header THT 2x34 1.00mm double row +0 +68 +68 +Connector_PinHeader_1.00mm +PinHeader_2x34_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x34 1.00mm double row +0 +68 +68 +Connector_PinHeader_1.00mm +PinHeader_2x35_P1.00mm_Horizontal +Through hole angled pin header, 2x35, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x35 1.00mm double row +0 +70 +70 +Connector_PinHeader_1.00mm +PinHeader_2x35_P1.00mm_Vertical +Through hole straight pin header, 2x35, 1.00mm pitch, double rows +Through hole pin header THT 2x35 1.00mm double row +0 +70 +70 +Connector_PinHeader_1.00mm +PinHeader_2x35_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x35 1.00mm double row +0 +70 +70 +Connector_PinHeader_1.00mm +PinHeader_2x36_P1.00mm_Horizontal +Through hole angled pin header, 2x36, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x36 1.00mm double row +0 +72 +72 +Connector_PinHeader_1.00mm +PinHeader_2x36_P1.00mm_Vertical +Through hole straight pin header, 2x36, 1.00mm pitch, double rows +Through hole pin header THT 2x36 1.00mm double row +0 +72 +72 +Connector_PinHeader_1.00mm +PinHeader_2x36_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x36 1.00mm double row +0 +72 +72 +Connector_PinHeader_1.00mm +PinHeader_2x37_P1.00mm_Horizontal +Through hole angled pin header, 2x37, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x37 1.00mm double row +0 +74 +74 +Connector_PinHeader_1.00mm +PinHeader_2x37_P1.00mm_Vertical +Through hole straight pin header, 2x37, 1.00mm pitch, double rows +Through hole pin header THT 2x37 1.00mm double row +0 +74 +74 +Connector_PinHeader_1.00mm +PinHeader_2x37_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x37 1.00mm double row +0 +74 +74 +Connector_PinHeader_1.00mm +PinHeader_2x38_P1.00mm_Horizontal +Through hole angled pin header, 2x38, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x38 1.00mm double row +0 +76 +76 +Connector_PinHeader_1.00mm +PinHeader_2x38_P1.00mm_Vertical +Through hole straight pin header, 2x38, 1.00mm pitch, double rows +Through hole pin header THT 2x38 1.00mm double row +0 +76 +76 +Connector_PinHeader_1.00mm +PinHeader_2x38_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x38 1.00mm double row +0 +76 +76 +Connector_PinHeader_1.00mm +PinHeader_2x39_P1.00mm_Horizontal +Through hole angled pin header, 2x39, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x39 1.00mm double row +0 +78 +78 +Connector_PinHeader_1.00mm +PinHeader_2x39_P1.00mm_Vertical +Through hole straight pin header, 2x39, 1.00mm pitch, double rows +Through hole pin header THT 2x39 1.00mm double row +0 +78 +78 +Connector_PinHeader_1.00mm +PinHeader_2x39_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x39 1.00mm double row +0 +78 +78 +Connector_PinHeader_1.00mm +PinHeader_2x40_P1.00mm_Horizontal +Through hole angled pin header, 2x40, 1.00mm pitch, 2.0mm pin length, double rows +Through hole angled pin header THT 2x40 1.00mm double row +0 +80 +80 +Connector_PinHeader_1.00mm +PinHeader_2x40_P1.00mm_Vertical +Through hole straight pin header, 2x40, 1.00mm pitch, double rows +Through hole pin header THT 2x40 1.00mm double row +0 +80 +80 +Connector_PinHeader_1.00mm +PinHeader_2x40_P1.00mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 1.00mm pitch, double rows +Surface mounted pin header SMD 2x40 1.00mm double row +0 +80 +80 +Connector_PinHeader_1.27mm +PinHeader_1x01_P1.27mm_Horizontal +Through hole angled pin header, 1x01, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x01 1.27mm single row +0 +1 +1 +Connector_PinHeader_1.27mm +PinHeader_1x01_P1.27mm_Vertical +Through hole straight pin header, 1x01, 1.27mm pitch, single row +Through hole pin header THT 1x01 1.27mm single row +0 +1 +1 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Horizontal +Through hole angled pin header, 1x02, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x02 1.27mm single row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Vertical +Through hole straight pin header, 1x02, 1.27mm pitch, single row +Through hole pin header THT 1x02 1.27mm single row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 1.27mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x02_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 1.27mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Horizontal +Through hole angled pin header, 1x03, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x03 1.27mm single row +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Vertical +Through hole straight pin header, 1x03, 1.27mm pitch, single row +Through hole pin header THT 1x03 1.27mm single row +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 1.27mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x03_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 1.27mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Horizontal +Through hole angled pin header, 1x04, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x04 1.27mm single row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Vertical +Through hole straight pin header, 1x04, 1.27mm pitch, single row +Through hole pin header THT 1x04 1.27mm single row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 1.27mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x04_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 1.27mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Horizontal +Through hole angled pin header, 1x05, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x05 1.27mm single row +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Vertical +Through hole straight pin header, 1x05, 1.27mm pitch, single row +Through hole pin header THT 1x05 1.27mm single row +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 1.27mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x05_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 1.27mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Horizontal +Through hole angled pin header, 1x06, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x06 1.27mm single row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Vertical +Through hole straight pin header, 1x06, 1.27mm pitch, single row +Through hole pin header THT 1x06 1.27mm single row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 1.27mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x06_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 1.27mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Horizontal +Through hole angled pin header, 1x07, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x07 1.27mm single row +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Vertical +Through hole straight pin header, 1x07, 1.27mm pitch, single row +Through hole pin header THT 1x07 1.27mm single row +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 1.27mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x07_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 1.27mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Horizontal +Through hole angled pin header, 1x08, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x08 1.27mm single row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Vertical +Through hole straight pin header, 1x08, 1.27mm pitch, single row +Through hole pin header THT 1x08 1.27mm single row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 1.27mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x08_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 1.27mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Horizontal +Through hole angled pin header, 1x09, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x09 1.27mm single row +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Vertical +Through hole straight pin header, 1x09, 1.27mm pitch, single row +Through hole pin header THT 1x09 1.27mm single row +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 1.27mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x09_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 1.27mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Horizontal +Through hole angled pin header, 1x10, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x10 1.27mm single row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Vertical +Through hole straight pin header, 1x10, 1.27mm pitch, single row +Through hole pin header THT 1x10 1.27mm single row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 1.27mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x10_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 1.27mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Horizontal +Through hole angled pin header, 1x11, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x11 1.27mm single row +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Vertical +Through hole straight pin header, 1x11, 1.27mm pitch, single row +Through hole pin header THT 1x11 1.27mm single row +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 1.27mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x11_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 1.27mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Horizontal +Through hole angled pin header, 1x12, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x12 1.27mm single row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Vertical +Through hole straight pin header, 1x12, 1.27mm pitch, single row +Through hole pin header THT 1x12 1.27mm single row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 1.27mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x12_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 1.27mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Horizontal +Through hole angled pin header, 1x13, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x13 1.27mm single row +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Vertical +Through hole straight pin header, 1x13, 1.27mm pitch, single row +Through hole pin header THT 1x13 1.27mm single row +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 1.27mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x13_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 1.27mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Horizontal +Through hole angled pin header, 1x14, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x14 1.27mm single row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Vertical +Through hole straight pin header, 1x14, 1.27mm pitch, single row +Through hole pin header THT 1x14 1.27mm single row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 1.27mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x14_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 1.27mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Horizontal +Through hole angled pin header, 1x15, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x15 1.27mm single row +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Vertical +Through hole straight pin header, 1x15, 1.27mm pitch, single row +Through hole pin header THT 1x15 1.27mm single row +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 1.27mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x15_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 1.27mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Horizontal +Through hole angled pin header, 1x16, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x16 1.27mm single row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Vertical +Through hole straight pin header, 1x16, 1.27mm pitch, single row +Through hole pin header THT 1x16 1.27mm single row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 1.27mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x16_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 1.27mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Horizontal +Through hole angled pin header, 1x17, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x17 1.27mm single row +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Vertical +Through hole straight pin header, 1x17, 1.27mm pitch, single row +Through hole pin header THT 1x17 1.27mm single row +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 1.27mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x17_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 1.27mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Horizontal +Through hole angled pin header, 1x18, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x18 1.27mm single row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Vertical +Through hole straight pin header, 1x18, 1.27mm pitch, single row +Through hole pin header THT 1x18 1.27mm single row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 1.27mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x18_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 1.27mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Horizontal +Through hole angled pin header, 1x19, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x19 1.27mm single row +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Vertical +Through hole straight pin header, 1x19, 1.27mm pitch, single row +Through hole pin header THT 1x19 1.27mm single row +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 1.27mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x19_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 1.27mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Horizontal +Through hole angled pin header, 1x20, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x20 1.27mm single row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Vertical +Through hole straight pin header, 1x20, 1.27mm pitch, single row +Through hole pin header THT 1x20 1.27mm single row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 1.27mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x20_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 1.27mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Horizontal +Through hole angled pin header, 1x21, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x21 1.27mm single row +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Vertical +Through hole straight pin header, 1x21, 1.27mm pitch, single row +Through hole pin header THT 1x21 1.27mm single row +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 1.27mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x21_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 1.27mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Horizontal +Through hole angled pin header, 1x22, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x22 1.27mm single row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Vertical +Through hole straight pin header, 1x22, 1.27mm pitch, single row +Through hole pin header THT 1x22 1.27mm single row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 1.27mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x22_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 1.27mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Horizontal +Through hole angled pin header, 1x23, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x23 1.27mm single row +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Vertical +Through hole straight pin header, 1x23, 1.27mm pitch, single row +Through hole pin header THT 1x23 1.27mm single row +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 1.27mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x23_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 1.27mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Horizontal +Through hole angled pin header, 1x24, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x24 1.27mm single row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Vertical +Through hole straight pin header, 1x24, 1.27mm pitch, single row +Through hole pin header THT 1x24 1.27mm single row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 1.27mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x24_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 1.27mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Horizontal +Through hole angled pin header, 1x25, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x25 1.27mm single row +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Vertical +Through hole straight pin header, 1x25, 1.27mm pitch, single row +Through hole pin header THT 1x25 1.27mm single row +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 1.27mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x25_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 1.27mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Horizontal +Through hole angled pin header, 1x26, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x26 1.27mm single row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Vertical +Through hole straight pin header, 1x26, 1.27mm pitch, single row +Through hole pin header THT 1x26 1.27mm single row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 1.27mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x26_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 1.27mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Horizontal +Through hole angled pin header, 1x27, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x27 1.27mm single row +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Vertical +Through hole straight pin header, 1x27, 1.27mm pitch, single row +Through hole pin header THT 1x27 1.27mm single row +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 1.27mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x27_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 1.27mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Horizontal +Through hole angled pin header, 1x28, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x28 1.27mm single row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Vertical +Through hole straight pin header, 1x28, 1.27mm pitch, single row +Through hole pin header THT 1x28 1.27mm single row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 1.27mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x28_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 1.27mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Horizontal +Through hole angled pin header, 1x29, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x29 1.27mm single row +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Vertical +Through hole straight pin header, 1x29, 1.27mm pitch, single row +Through hole pin header THT 1x29 1.27mm single row +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 1.27mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x29_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 1.27mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Horizontal +Through hole angled pin header, 1x30, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x30 1.27mm single row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Vertical +Through hole straight pin header, 1x30, 1.27mm pitch, single row +Through hole pin header THT 1x30 1.27mm single row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 1.27mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x30_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 1.27mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Horizontal +Through hole angled pin header, 1x31, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x31 1.27mm single row +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Vertical +Through hole straight pin header, 1x31, 1.27mm pitch, single row +Through hole pin header THT 1x31 1.27mm single row +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 1.27mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x31_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 1.27mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Horizontal +Through hole angled pin header, 1x32, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x32 1.27mm single row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Vertical +Through hole straight pin header, 1x32, 1.27mm pitch, single row +Through hole pin header THT 1x32 1.27mm single row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 1.27mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x32_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 1.27mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Horizontal +Through hole angled pin header, 1x33, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x33 1.27mm single row +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Vertical +Through hole straight pin header, 1x33, 1.27mm pitch, single row +Through hole pin header THT 1x33 1.27mm single row +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 1.27mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x33_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 1.27mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Horizontal +Through hole angled pin header, 1x34, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x34 1.27mm single row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Vertical +Through hole straight pin header, 1x34, 1.27mm pitch, single row +Through hole pin header THT 1x34 1.27mm single row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 1.27mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x34_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 1.27mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Horizontal +Through hole angled pin header, 1x35, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x35 1.27mm single row +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Vertical +Through hole straight pin header, 1x35, 1.27mm pitch, single row +Through hole pin header THT 1x35 1.27mm single row +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 1.27mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x35_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 1.27mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Horizontal +Through hole angled pin header, 1x36, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x36 1.27mm single row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Vertical +Through hole straight pin header, 1x36, 1.27mm pitch, single row +Through hole pin header THT 1x36 1.27mm single row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 1.27mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x36_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 1.27mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Horizontal +Through hole angled pin header, 1x37, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x37 1.27mm single row +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Vertical +Through hole straight pin header, 1x37, 1.27mm pitch, single row +Through hole pin header THT 1x37 1.27mm single row +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 1.27mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x37_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 1.27mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Horizontal +Through hole angled pin header, 1x38, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x38 1.27mm single row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Vertical +Through hole straight pin header, 1x38, 1.27mm pitch, single row +Through hole pin header THT 1x38 1.27mm single row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 1.27mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x38_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 1.27mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Horizontal +Through hole angled pin header, 1x39, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x39 1.27mm single row +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Vertical +Through hole straight pin header, 1x39, 1.27mm pitch, single row +Through hole pin header THT 1x39 1.27mm single row +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 1.27mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x39_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 1.27mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Horizontal +Through hole angled pin header, 1x40, 1.27mm pitch, 4.0mm pin length, single row +Through hole angled pin header THT 1x40 1.27mm single row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Vertical +Through hole straight pin header, 1x40, 1.27mm pitch, single row +Through hole pin header THT 1x40 1.27mm single row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 1.27mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 1.27mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_1x40_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 1.27mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 1.27mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x01_P1.27mm_Horizontal +Through hole angled pin header, 2x01, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x01 1.27mm double row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_2x01_P1.27mm_Vertical +Through hole straight pin header, 2x01, 1.27mm pitch, double rows +Through hole pin header THT 2x01 1.27mm double row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_2x01_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x01 1.27mm double row +0 +2 +2 +Connector_PinHeader_1.27mm +PinHeader_2x02_P1.27mm_Horizontal +Through hole angled pin header, 2x02, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x02 1.27mm double row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_2x02_P1.27mm_Vertical +Through hole straight pin header, 2x02, 1.27mm pitch, double rows +Through hole pin header THT 2x02 1.27mm double row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_2x02_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x02 1.27mm double row +0 +4 +4 +Connector_PinHeader_1.27mm +PinHeader_2x03_P1.27mm_Horizontal +Through hole angled pin header, 2x03, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_2x03_P1.27mm_Vertical +Through hole straight pin header, 2x03, 1.27mm pitch, double rows +Through hole pin header THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_2x03_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x03 1.27mm double row +0 +6 +6 +Connector_PinHeader_1.27mm +PinHeader_2x04_P1.27mm_Horizontal +Through hole angled pin header, 2x04, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_2x04_P1.27mm_Vertical +Through hole straight pin header, 2x04, 1.27mm pitch, double rows +Through hole pin header THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_2x04_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x04 1.27mm double row +0 +8 +8 +Connector_PinHeader_1.27mm +PinHeader_2x05_P1.27mm_Horizontal +Through hole angled pin header, 2x05, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_2x05_P1.27mm_Vertical +Through hole straight pin header, 2x05, 1.27mm pitch, double rows +Through hole pin header THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_2x05_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x05 1.27mm double row +0 +10 +10 +Connector_PinHeader_1.27mm +PinHeader_2x06_P1.27mm_Horizontal +Through hole angled pin header, 2x06, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_2x06_P1.27mm_Vertical +Through hole straight pin header, 2x06, 1.27mm pitch, double rows +Through hole pin header THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_2x06_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x06 1.27mm double row +0 +12 +12 +Connector_PinHeader_1.27mm +PinHeader_2x07_P1.27mm_Horizontal +Through hole angled pin header, 2x07, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_2x07_P1.27mm_Vertical +Through hole straight pin header, 2x07, 1.27mm pitch, double rows +Through hole pin header THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_2x07_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x07 1.27mm double row +0 +14 +14 +Connector_PinHeader_1.27mm +PinHeader_2x08_P1.27mm_Horizontal +Through hole angled pin header, 2x08, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_2x08_P1.27mm_Vertical +Through hole straight pin header, 2x08, 1.27mm pitch, double rows +Through hole pin header THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_2x08_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x08 1.27mm double row +0 +16 +16 +Connector_PinHeader_1.27mm +PinHeader_2x09_P1.27mm_Horizontal +Through hole angled pin header, 2x09, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_2x09_P1.27mm_Vertical +Through hole straight pin header, 2x09, 1.27mm pitch, double rows +Through hole pin header THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_2x09_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x09 1.27mm double row +0 +18 +18 +Connector_PinHeader_1.27mm +PinHeader_2x10_P1.27mm_Horizontal +Through hole angled pin header, 2x10, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_2x10_P1.27mm_Vertical +Through hole straight pin header, 2x10, 1.27mm pitch, double rows +Through hole pin header THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_2x10_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x10 1.27mm double row +0 +20 +20 +Connector_PinHeader_1.27mm +PinHeader_2x11_P1.27mm_Horizontal +Through hole angled pin header, 2x11, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_2x11_P1.27mm_Vertical +Through hole straight pin header, 2x11, 1.27mm pitch, double rows +Through hole pin header THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_2x11_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x11 1.27mm double row +0 +22 +22 +Connector_PinHeader_1.27mm +PinHeader_2x12_P1.27mm_Horizontal +Through hole angled pin header, 2x12, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_2x12_P1.27mm_Vertical +Through hole straight pin header, 2x12, 1.27mm pitch, double rows +Through hole pin header THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_2x12_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x12 1.27mm double row +0 +24 +24 +Connector_PinHeader_1.27mm +PinHeader_2x13_P1.27mm_Horizontal +Through hole angled pin header, 2x13, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_2x13_P1.27mm_Vertical +Through hole straight pin header, 2x13, 1.27mm pitch, double rows +Through hole pin header THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_2x13_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x13 1.27mm double row +0 +26 +26 +Connector_PinHeader_1.27mm +PinHeader_2x14_P1.27mm_Horizontal +Through hole angled pin header, 2x14, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_2x14_P1.27mm_Vertical +Through hole straight pin header, 2x14, 1.27mm pitch, double rows +Through hole pin header THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_2x14_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x14 1.27mm double row +0 +28 +28 +Connector_PinHeader_1.27mm +PinHeader_2x15_P1.27mm_Horizontal +Through hole angled pin header, 2x15, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_2x15_P1.27mm_Vertical +Through hole straight pin header, 2x15, 1.27mm pitch, double rows +Through hole pin header THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_2x15_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x15 1.27mm double row +0 +30 +30 +Connector_PinHeader_1.27mm +PinHeader_2x16_P1.27mm_Horizontal +Through hole angled pin header, 2x16, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_2x16_P1.27mm_Vertical +Through hole straight pin header, 2x16, 1.27mm pitch, double rows +Through hole pin header THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_2x16_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x16 1.27mm double row +0 +32 +32 +Connector_PinHeader_1.27mm +PinHeader_2x17_P1.27mm_Horizontal +Through hole angled pin header, 2x17, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_2x17_P1.27mm_Vertical +Through hole straight pin header, 2x17, 1.27mm pitch, double rows +Through hole pin header THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_2x17_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x17 1.27mm double row +0 +34 +34 +Connector_PinHeader_1.27mm +PinHeader_2x18_P1.27mm_Horizontal +Through hole angled pin header, 2x18, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_2x18_P1.27mm_Vertical +Through hole straight pin header, 2x18, 1.27mm pitch, double rows +Through hole pin header THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_2x18_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x18 1.27mm double row +0 +36 +36 +Connector_PinHeader_1.27mm +PinHeader_2x19_P1.27mm_Horizontal +Through hole angled pin header, 2x19, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_2x19_P1.27mm_Vertical +Through hole straight pin header, 2x19, 1.27mm pitch, double rows +Through hole pin header THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_2x19_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x19 1.27mm double row +0 +38 +38 +Connector_PinHeader_1.27mm +PinHeader_2x20_P1.27mm_Horizontal +Through hole angled pin header, 2x20, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x20_P1.27mm_Vertical +Through hole straight pin header, 2x20, 1.27mm pitch, double rows +Through hole pin header THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x20_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x20 1.27mm double row +0 +40 +40 +Connector_PinHeader_1.27mm +PinHeader_2x21_P1.27mm_Horizontal +Through hole angled pin header, 2x21, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinHeader_1.27mm +PinHeader_2x21_P1.27mm_Vertical +Through hole straight pin header, 2x21, 1.27mm pitch, double rows +Through hole pin header THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinHeader_1.27mm +PinHeader_2x21_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x21 1.27mm double row +0 +42 +42 +Connector_PinHeader_1.27mm +PinHeader_2x22_P1.27mm_Horizontal +Through hole angled pin header, 2x22, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinHeader_1.27mm +PinHeader_2x22_P1.27mm_Vertical +Through hole straight pin header, 2x22, 1.27mm pitch, double rows +Through hole pin header THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinHeader_1.27mm +PinHeader_2x22_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x22 1.27mm double row +0 +44 +44 +Connector_PinHeader_1.27mm +PinHeader_2x23_P1.27mm_Horizontal +Through hole angled pin header, 2x23, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinHeader_1.27mm +PinHeader_2x23_P1.27mm_Vertical +Through hole straight pin header, 2x23, 1.27mm pitch, double rows +Through hole pin header THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinHeader_1.27mm +PinHeader_2x23_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x23 1.27mm double row +0 +46 +46 +Connector_PinHeader_1.27mm +PinHeader_2x24_P1.27mm_Horizontal +Through hole angled pin header, 2x24, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinHeader_1.27mm +PinHeader_2x24_P1.27mm_Vertical +Through hole straight pin header, 2x24, 1.27mm pitch, double rows +Through hole pin header THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinHeader_1.27mm +PinHeader_2x24_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x24 1.27mm double row +0 +48 +48 +Connector_PinHeader_1.27mm +PinHeader_2x25_P1.27mm_Horizontal +Through hole angled pin header, 2x25, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinHeader_1.27mm +PinHeader_2x25_P1.27mm_Vertical +Through hole straight pin header, 2x25, 1.27mm pitch, double rows +Through hole pin header THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinHeader_1.27mm +PinHeader_2x25_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x25 1.27mm double row +0 +50 +50 +Connector_PinHeader_1.27mm +PinHeader_2x26_P1.27mm_Horizontal +Through hole angled pin header, 2x26, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinHeader_1.27mm +PinHeader_2x26_P1.27mm_Vertical +Through hole straight pin header, 2x26, 1.27mm pitch, double rows +Through hole pin header THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinHeader_1.27mm +PinHeader_2x26_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x26 1.27mm double row +0 +52 +52 +Connector_PinHeader_1.27mm +PinHeader_2x27_P1.27mm_Horizontal +Through hole angled pin header, 2x27, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinHeader_1.27mm +PinHeader_2x27_P1.27mm_Vertical +Through hole straight pin header, 2x27, 1.27mm pitch, double rows +Through hole pin header THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinHeader_1.27mm +PinHeader_2x27_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x27 1.27mm double row +0 +54 +54 +Connector_PinHeader_1.27mm +PinHeader_2x28_P1.27mm_Horizontal +Through hole angled pin header, 2x28, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinHeader_1.27mm +PinHeader_2x28_P1.27mm_Vertical +Through hole straight pin header, 2x28, 1.27mm pitch, double rows +Through hole pin header THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinHeader_1.27mm +PinHeader_2x28_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x28 1.27mm double row +0 +56 +56 +Connector_PinHeader_1.27mm +PinHeader_2x29_P1.27mm_Horizontal +Through hole angled pin header, 2x29, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinHeader_1.27mm +PinHeader_2x29_P1.27mm_Vertical +Through hole straight pin header, 2x29, 1.27mm pitch, double rows +Through hole pin header THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinHeader_1.27mm +PinHeader_2x29_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x29 1.27mm double row +0 +58 +58 +Connector_PinHeader_1.27mm +PinHeader_2x30_P1.27mm_Horizontal +Through hole angled pin header, 2x30, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinHeader_1.27mm +PinHeader_2x30_P1.27mm_Vertical +Through hole straight pin header, 2x30, 1.27mm pitch, double rows +Through hole pin header THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinHeader_1.27mm +PinHeader_2x30_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x30 1.27mm double row +0 +60 +60 +Connector_PinHeader_1.27mm +PinHeader_2x31_P1.27mm_Horizontal +Through hole angled pin header, 2x31, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinHeader_1.27mm +PinHeader_2x31_P1.27mm_Vertical +Through hole straight pin header, 2x31, 1.27mm pitch, double rows +Through hole pin header THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinHeader_1.27mm +PinHeader_2x31_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x31 1.27mm double row +0 +62 +62 +Connector_PinHeader_1.27mm +PinHeader_2x32_P1.27mm_Horizontal +Through hole angled pin header, 2x32, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinHeader_1.27mm +PinHeader_2x32_P1.27mm_Vertical +Through hole straight pin header, 2x32, 1.27mm pitch, double rows +Through hole pin header THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinHeader_1.27mm +PinHeader_2x32_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x32 1.27mm double row +0 +64 +64 +Connector_PinHeader_1.27mm +PinHeader_2x33_P1.27mm_Horizontal +Through hole angled pin header, 2x33, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinHeader_1.27mm +PinHeader_2x33_P1.27mm_Vertical +Through hole straight pin header, 2x33, 1.27mm pitch, double rows +Through hole pin header THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinHeader_1.27mm +PinHeader_2x33_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x33 1.27mm double row +0 +66 +66 +Connector_PinHeader_1.27mm +PinHeader_2x34_P1.27mm_Horizontal +Through hole angled pin header, 2x34, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinHeader_1.27mm +PinHeader_2x34_P1.27mm_Vertical +Through hole straight pin header, 2x34, 1.27mm pitch, double rows +Through hole pin header THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinHeader_1.27mm +PinHeader_2x34_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x34 1.27mm double row +0 +68 +68 +Connector_PinHeader_1.27mm +PinHeader_2x35_P1.27mm_Horizontal +Through hole angled pin header, 2x35, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinHeader_1.27mm +PinHeader_2x35_P1.27mm_Vertical +Through hole straight pin header, 2x35, 1.27mm pitch, double rows +Through hole pin header THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinHeader_1.27mm +PinHeader_2x35_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x35 1.27mm double row +0 +70 +70 +Connector_PinHeader_1.27mm +PinHeader_2x36_P1.27mm_Horizontal +Through hole angled pin header, 2x36, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinHeader_1.27mm +PinHeader_2x36_P1.27mm_Vertical +Through hole straight pin header, 2x36, 1.27mm pitch, double rows +Through hole pin header THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinHeader_1.27mm +PinHeader_2x36_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x36 1.27mm double row +0 +72 +72 +Connector_PinHeader_1.27mm +PinHeader_2x37_P1.27mm_Horizontal +Through hole angled pin header, 2x37, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinHeader_1.27mm +PinHeader_2x37_P1.27mm_Vertical +Through hole straight pin header, 2x37, 1.27mm pitch, double rows +Through hole pin header THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinHeader_1.27mm +PinHeader_2x37_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x37 1.27mm double row +0 +74 +74 +Connector_PinHeader_1.27mm +PinHeader_2x38_P1.27mm_Horizontal +Through hole angled pin header, 2x38, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinHeader_1.27mm +PinHeader_2x38_P1.27mm_Vertical +Through hole straight pin header, 2x38, 1.27mm pitch, double rows +Through hole pin header THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinHeader_1.27mm +PinHeader_2x38_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x38 1.27mm double row +0 +76 +76 +Connector_PinHeader_1.27mm +PinHeader_2x39_P1.27mm_Horizontal +Through hole angled pin header, 2x39, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinHeader_1.27mm +PinHeader_2x39_P1.27mm_Vertical +Through hole straight pin header, 2x39, 1.27mm pitch, double rows +Through hole pin header THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinHeader_1.27mm +PinHeader_2x39_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x39 1.27mm double row +0 +78 +78 +Connector_PinHeader_1.27mm +PinHeader_2x40_P1.27mm_Horizontal +Through hole angled pin header, 2x40, 1.27mm pitch, 4.0mm pin length, double rows +Through hole angled pin header THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinHeader_1.27mm +PinHeader_2x40_P1.27mm_Vertical +Through hole straight pin header, 2x40, 1.27mm pitch, double rows +Through hole pin header THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinHeader_1.27mm +PinHeader_2x40_P1.27mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 1.27mm pitch, double rows +Surface mounted pin header SMD 2x40 1.27mm double row +0 +80 +80 +Connector_PinHeader_2.00mm +PinHeader_1x01_P2.00mm_Horizontal +Through hole angled pin header, 1x01, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinHeader_2.00mm +PinHeader_1x01_P2.00mm_Vertical +Through hole straight pin header, 1x01, 2.00mm pitch, single row +Through hole pin header THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Horizontal +Through hole angled pin header, 1x02, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Vertical +Through hole straight pin header, 1x02, 2.00mm pitch, single row +Through hole pin header THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 2.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x02_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 2.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Horizontal +Through hole angled pin header, 1x03, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Vertical +Through hole straight pin header, 1x03, 2.00mm pitch, single row +Through hole pin header THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 2.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x03_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 2.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Horizontal +Through hole angled pin header, 1x04, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Vertical +Through hole straight pin header, 1x04, 2.00mm pitch, single row +Through hole pin header THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 2.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x04_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 2.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Horizontal +Through hole angled pin header, 1x05, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Vertical +Through hole straight pin header, 1x05, 2.00mm pitch, single row +Through hole pin header THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 2.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x05_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 2.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Horizontal +Through hole angled pin header, 1x06, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Vertical +Through hole straight pin header, 1x06, 2.00mm pitch, single row +Through hole pin header THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 2.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x06_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 2.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Horizontal +Through hole angled pin header, 1x07, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Vertical +Through hole straight pin header, 1x07, 2.00mm pitch, single row +Through hole pin header THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 2.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x07_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 2.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Horizontal +Through hole angled pin header, 1x08, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Vertical +Through hole straight pin header, 1x08, 2.00mm pitch, single row +Through hole pin header THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 2.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x08_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 2.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Horizontal +Through hole angled pin header, 1x09, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Vertical +Through hole straight pin header, 1x09, 2.00mm pitch, single row +Through hole pin header THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 2.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x09_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 2.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Horizontal +Through hole angled pin header, 1x10, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Vertical +Through hole straight pin header, 1x10, 2.00mm pitch, single row +Through hole pin header THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 2.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x10_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 2.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Horizontal +Through hole angled pin header, 1x11, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Vertical +Through hole straight pin header, 1x11, 2.00mm pitch, single row +Through hole pin header THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 2.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x11_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 2.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Horizontal +Through hole angled pin header, 1x12, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Vertical +Through hole straight pin header, 1x12, 2.00mm pitch, single row +Through hole pin header THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 2.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x12_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 2.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Horizontal +Through hole angled pin header, 1x13, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Vertical +Through hole straight pin header, 1x13, 2.00mm pitch, single row +Through hole pin header THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 2.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x13_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 2.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Horizontal +Through hole angled pin header, 1x14, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Vertical +Through hole straight pin header, 1x14, 2.00mm pitch, single row +Through hole pin header THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 2.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x14_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 2.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Horizontal +Through hole angled pin header, 1x15, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Vertical +Through hole straight pin header, 1x15, 2.00mm pitch, single row +Through hole pin header THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 2.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x15_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 2.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Horizontal +Through hole angled pin header, 1x16, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Vertical +Through hole straight pin header, 1x16, 2.00mm pitch, single row +Through hole pin header THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 2.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x16_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 2.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Horizontal +Through hole angled pin header, 1x17, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Vertical +Through hole straight pin header, 1x17, 2.00mm pitch, single row +Through hole pin header THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 2.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x17_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 2.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Horizontal +Through hole angled pin header, 1x18, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Vertical +Through hole straight pin header, 1x18, 2.00mm pitch, single row +Through hole pin header THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 2.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x18_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 2.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Horizontal +Through hole angled pin header, 1x19, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Vertical +Through hole straight pin header, 1x19, 2.00mm pitch, single row +Through hole pin header THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 2.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x19_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 2.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Horizontal +Through hole angled pin header, 1x20, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Vertical +Through hole straight pin header, 1x20, 2.00mm pitch, single row +Through hole pin header THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 2.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x20_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 2.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Horizontal +Through hole angled pin header, 1x21, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Vertical +Through hole straight pin header, 1x21, 2.00mm pitch, single row +Through hole pin header THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 2.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x21_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 2.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Horizontal +Through hole angled pin header, 1x22, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Vertical +Through hole straight pin header, 1x22, 2.00mm pitch, single row +Through hole pin header THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 2.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x22_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 2.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Horizontal +Through hole angled pin header, 1x23, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Vertical +Through hole straight pin header, 1x23, 2.00mm pitch, single row +Through hole pin header THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 2.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x23_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 2.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Horizontal +Through hole angled pin header, 1x24, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Vertical +Through hole straight pin header, 1x24, 2.00mm pitch, single row +Through hole pin header THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 2.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x24_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 2.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Horizontal +Through hole angled pin header, 1x25, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Vertical +Through hole straight pin header, 1x25, 2.00mm pitch, single row +Through hole pin header THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 2.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x25_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 2.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Horizontal +Through hole angled pin header, 1x26, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Vertical +Through hole straight pin header, 1x26, 2.00mm pitch, single row +Through hole pin header THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 2.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x26_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 2.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Horizontal +Through hole angled pin header, 1x27, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Vertical +Through hole straight pin header, 1x27, 2.00mm pitch, single row +Through hole pin header THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 2.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x27_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 2.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Horizontal +Through hole angled pin header, 1x28, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Vertical +Through hole straight pin header, 1x28, 2.00mm pitch, single row +Through hole pin header THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 2.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x28_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 2.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Horizontal +Through hole angled pin header, 1x29, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Vertical +Through hole straight pin header, 1x29, 2.00mm pitch, single row +Through hole pin header THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 2.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x29_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 2.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Horizontal +Through hole angled pin header, 1x30, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Vertical +Through hole straight pin header, 1x30, 2.00mm pitch, single row +Through hole pin header THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 2.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x30_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 2.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Horizontal +Through hole angled pin header, 1x31, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Vertical +Through hole straight pin header, 1x31, 2.00mm pitch, single row +Through hole pin header THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 2.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x31_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 2.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Horizontal +Through hole angled pin header, 1x32, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Vertical +Through hole straight pin header, 1x32, 2.00mm pitch, single row +Through hole pin header THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 2.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x32_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 2.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Horizontal +Through hole angled pin header, 1x33, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Vertical +Through hole straight pin header, 1x33, 2.00mm pitch, single row +Through hole pin header THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 2.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x33_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 2.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Horizontal +Through hole angled pin header, 1x34, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Vertical +Through hole straight pin header, 1x34, 2.00mm pitch, single row +Through hole pin header THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 2.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x34_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 2.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Horizontal +Through hole angled pin header, 1x35, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Vertical +Through hole straight pin header, 1x35, 2.00mm pitch, single row +Through hole pin header THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 2.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x35_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 2.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Horizontal +Through hole angled pin header, 1x36, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Vertical +Through hole straight pin header, 1x36, 2.00mm pitch, single row +Through hole pin header THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 2.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x36_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 2.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Horizontal +Through hole angled pin header, 1x37, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Vertical +Through hole straight pin header, 1x37, 2.00mm pitch, single row +Through hole pin header THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 2.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x37_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 2.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Horizontal +Through hole angled pin header, 1x38, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Vertical +Through hole straight pin header, 1x38, 2.00mm pitch, single row +Through hole pin header THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 2.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x38_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 2.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Horizontal +Through hole angled pin header, 1x39, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Vertical +Through hole straight pin header, 1x39, 2.00mm pitch, single row +Through hole pin header THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 2.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x39_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 2.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Horizontal +Through hole angled pin header, 1x40, 2.00mm pitch, 4.2mm pin length, single row +Through hole angled pin header THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Vertical +Through hole straight pin header, 1x40, 2.00mm pitch, single row +Through hole pin header THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 2.00mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 2.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_1x40_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 2.00mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 2.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x01_P2.00mm_Horizontal +Through hole angled pin header, 2x01, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_2x01_P2.00mm_Vertical +Through hole straight pin header, 2x01, 2.00mm pitch, double rows +Through hole pin header THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_2x01_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x01 2.00mm double row +0 +2 +2 +Connector_PinHeader_2.00mm +PinHeader_2x02_P2.00mm_Horizontal +Through hole angled pin header, 2x02, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_2x02_P2.00mm_Vertical +Through hole straight pin header, 2x02, 2.00mm pitch, double rows +Through hole pin header THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_2x02_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x02 2.00mm double row +0 +4 +4 +Connector_PinHeader_2.00mm +PinHeader_2x03_P2.00mm_Horizontal +Through hole angled pin header, 2x03, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_2x03_P2.00mm_Vertical +Through hole straight pin header, 2x03, 2.00mm pitch, double rows +Through hole pin header THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_2x03_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x03 2.00mm double row +0 +6 +6 +Connector_PinHeader_2.00mm +PinHeader_2x04_P2.00mm_Horizontal +Through hole angled pin header, 2x04, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_2x04_P2.00mm_Vertical +Through hole straight pin header, 2x04, 2.00mm pitch, double rows +Through hole pin header THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_2x04_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x04 2.00mm double row +0 +8 +8 +Connector_PinHeader_2.00mm +PinHeader_2x05_P2.00mm_Horizontal +Through hole angled pin header, 2x05, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_2x05_P2.00mm_Vertical +Through hole straight pin header, 2x05, 2.00mm pitch, double rows +Through hole pin header THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_2x05_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x05 2.00mm double row +0 +10 +10 +Connector_PinHeader_2.00mm +PinHeader_2x06_P2.00mm_Horizontal +Through hole angled pin header, 2x06, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_2x06_P2.00mm_Vertical +Through hole straight pin header, 2x06, 2.00mm pitch, double rows +Through hole pin header THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_2x06_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x06 2.00mm double row +0 +12 +12 +Connector_PinHeader_2.00mm +PinHeader_2x07_P2.00mm_Horizontal +Through hole angled pin header, 2x07, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_2x07_P2.00mm_Vertical +Through hole straight pin header, 2x07, 2.00mm pitch, double rows +Through hole pin header THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_2x07_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x07 2.00mm double row +0 +14 +14 +Connector_PinHeader_2.00mm +PinHeader_2x08_P2.00mm_Horizontal +Through hole angled pin header, 2x08, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_2x08_P2.00mm_Vertical +Through hole straight pin header, 2x08, 2.00mm pitch, double rows +Through hole pin header THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_2x08_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x08 2.00mm double row +0 +16 +16 +Connector_PinHeader_2.00mm +PinHeader_2x09_P2.00mm_Horizontal +Through hole angled pin header, 2x09, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_2x09_P2.00mm_Vertical +Through hole straight pin header, 2x09, 2.00mm pitch, double rows +Through hole pin header THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_2x09_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x09 2.00mm double row +0 +18 +18 +Connector_PinHeader_2.00mm +PinHeader_2x10_P2.00mm_Horizontal +Through hole angled pin header, 2x10, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_2x10_P2.00mm_Vertical +Through hole straight pin header, 2x10, 2.00mm pitch, double rows +Through hole pin header THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_2x10_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x10 2.00mm double row +0 +20 +20 +Connector_PinHeader_2.00mm +PinHeader_2x11_P2.00mm_Horizontal +Through hole angled pin header, 2x11, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_2x11_P2.00mm_Vertical +Through hole straight pin header, 2x11, 2.00mm pitch, double rows +Through hole pin header THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_2x11_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x11 2.00mm double row +0 +22 +22 +Connector_PinHeader_2.00mm +PinHeader_2x12_P2.00mm_Horizontal +Through hole angled pin header, 2x12, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_2x12_P2.00mm_Vertical +Through hole straight pin header, 2x12, 2.00mm pitch, double rows +Through hole pin header THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_2x12_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x12 2.00mm double row +0 +24 +24 +Connector_PinHeader_2.00mm +PinHeader_2x13_P2.00mm_Horizontal +Through hole angled pin header, 2x13, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_2x13_P2.00mm_Vertical +Through hole straight pin header, 2x13, 2.00mm pitch, double rows +Through hole pin header THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_2x13_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x13 2.00mm double row +0 +26 +26 +Connector_PinHeader_2.00mm +PinHeader_2x14_P2.00mm_Horizontal +Through hole angled pin header, 2x14, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_2x14_P2.00mm_Vertical +Through hole straight pin header, 2x14, 2.00mm pitch, double rows +Through hole pin header THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_2x14_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x14 2.00mm double row +0 +28 +28 +Connector_PinHeader_2.00mm +PinHeader_2x15_P2.00mm_Horizontal +Through hole angled pin header, 2x15, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_2x15_P2.00mm_Vertical +Through hole straight pin header, 2x15, 2.00mm pitch, double rows +Through hole pin header THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_2x15_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x15 2.00mm double row +0 +30 +30 +Connector_PinHeader_2.00mm +PinHeader_2x16_P2.00mm_Horizontal +Through hole angled pin header, 2x16, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_2x16_P2.00mm_Vertical +Through hole straight pin header, 2x16, 2.00mm pitch, double rows +Through hole pin header THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_2x16_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x16 2.00mm double row +0 +32 +32 +Connector_PinHeader_2.00mm +PinHeader_2x17_P2.00mm_Horizontal +Through hole angled pin header, 2x17, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_2x17_P2.00mm_Vertical +Through hole straight pin header, 2x17, 2.00mm pitch, double rows +Through hole pin header THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_2x17_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x17 2.00mm double row +0 +34 +34 +Connector_PinHeader_2.00mm +PinHeader_2x18_P2.00mm_Horizontal +Through hole angled pin header, 2x18, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_2x18_P2.00mm_Vertical +Through hole straight pin header, 2x18, 2.00mm pitch, double rows +Through hole pin header THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_2x18_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x18 2.00mm double row +0 +36 +36 +Connector_PinHeader_2.00mm +PinHeader_2x19_P2.00mm_Horizontal +Through hole angled pin header, 2x19, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_2x19_P2.00mm_Vertical +Through hole straight pin header, 2x19, 2.00mm pitch, double rows +Through hole pin header THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_2x19_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x19 2.00mm double row +0 +38 +38 +Connector_PinHeader_2.00mm +PinHeader_2x20_P2.00mm_Horizontal +Through hole angled pin header, 2x20, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x20_P2.00mm_Vertical +Through hole straight pin header, 2x20, 2.00mm pitch, double rows +Through hole pin header THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x20_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x20 2.00mm double row +0 +40 +40 +Connector_PinHeader_2.00mm +PinHeader_2x21_P2.00mm_Horizontal +Through hole angled pin header, 2x21, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinHeader_2.00mm +PinHeader_2x21_P2.00mm_Vertical +Through hole straight pin header, 2x21, 2.00mm pitch, double rows +Through hole pin header THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinHeader_2.00mm +PinHeader_2x21_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x21 2.00mm double row +0 +42 +42 +Connector_PinHeader_2.00mm +PinHeader_2x22_P2.00mm_Horizontal +Through hole angled pin header, 2x22, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinHeader_2.00mm +PinHeader_2x22_P2.00mm_Vertical +Through hole straight pin header, 2x22, 2.00mm pitch, double rows +Through hole pin header THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinHeader_2.00mm +PinHeader_2x22_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x22 2.00mm double row +0 +44 +44 +Connector_PinHeader_2.00mm +PinHeader_2x23_P2.00mm_Horizontal +Through hole angled pin header, 2x23, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinHeader_2.00mm +PinHeader_2x23_P2.00mm_Vertical +Through hole straight pin header, 2x23, 2.00mm pitch, double rows +Through hole pin header THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinHeader_2.00mm +PinHeader_2x23_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x23 2.00mm double row +0 +46 +46 +Connector_PinHeader_2.00mm +PinHeader_2x24_P2.00mm_Horizontal +Through hole angled pin header, 2x24, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinHeader_2.00mm +PinHeader_2x24_P2.00mm_Vertical +Through hole straight pin header, 2x24, 2.00mm pitch, double rows +Through hole pin header THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinHeader_2.00mm +PinHeader_2x24_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x24 2.00mm double row +0 +48 +48 +Connector_PinHeader_2.00mm +PinHeader_2x25_P2.00mm_Horizontal +Through hole angled pin header, 2x25, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinHeader_2.00mm +PinHeader_2x25_P2.00mm_Vertical +Through hole straight pin header, 2x25, 2.00mm pitch, double rows +Through hole pin header THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinHeader_2.00mm +PinHeader_2x25_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x25 2.00mm double row +0 +50 +50 +Connector_PinHeader_2.00mm +PinHeader_2x26_P2.00mm_Horizontal +Through hole angled pin header, 2x26, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinHeader_2.00mm +PinHeader_2x26_P2.00mm_Vertical +Through hole straight pin header, 2x26, 2.00mm pitch, double rows +Through hole pin header THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinHeader_2.00mm +PinHeader_2x26_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x26 2.00mm double row +0 +52 +52 +Connector_PinHeader_2.00mm +PinHeader_2x27_P2.00mm_Horizontal +Through hole angled pin header, 2x27, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinHeader_2.00mm +PinHeader_2x27_P2.00mm_Vertical +Through hole straight pin header, 2x27, 2.00mm pitch, double rows +Through hole pin header THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinHeader_2.00mm +PinHeader_2x27_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x27 2.00mm double row +0 +54 +54 +Connector_PinHeader_2.00mm +PinHeader_2x28_P2.00mm_Horizontal +Through hole angled pin header, 2x28, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinHeader_2.00mm +PinHeader_2x28_P2.00mm_Vertical +Through hole straight pin header, 2x28, 2.00mm pitch, double rows +Through hole pin header THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinHeader_2.00mm +PinHeader_2x28_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x28 2.00mm double row +0 +56 +56 +Connector_PinHeader_2.00mm +PinHeader_2x29_P2.00mm_Horizontal +Through hole angled pin header, 2x29, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinHeader_2.00mm +PinHeader_2x29_P2.00mm_Vertical +Through hole straight pin header, 2x29, 2.00mm pitch, double rows +Through hole pin header THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinHeader_2.00mm +PinHeader_2x29_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x29 2.00mm double row +0 +58 +58 +Connector_PinHeader_2.00mm +PinHeader_2x30_P2.00mm_Horizontal +Through hole angled pin header, 2x30, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinHeader_2.00mm +PinHeader_2x30_P2.00mm_Vertical +Through hole straight pin header, 2x30, 2.00mm pitch, double rows +Through hole pin header THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinHeader_2.00mm +PinHeader_2x30_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x30 2.00mm double row +0 +60 +60 +Connector_PinHeader_2.00mm +PinHeader_2x31_P2.00mm_Horizontal +Through hole angled pin header, 2x31, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinHeader_2.00mm +PinHeader_2x31_P2.00mm_Vertical +Through hole straight pin header, 2x31, 2.00mm pitch, double rows +Through hole pin header THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinHeader_2.00mm +PinHeader_2x31_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x31 2.00mm double row +0 +62 +62 +Connector_PinHeader_2.00mm +PinHeader_2x32_P2.00mm_Horizontal +Through hole angled pin header, 2x32, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinHeader_2.00mm +PinHeader_2x32_P2.00mm_Vertical +Through hole straight pin header, 2x32, 2.00mm pitch, double rows +Through hole pin header THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinHeader_2.00mm +PinHeader_2x32_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x32 2.00mm double row +0 +64 +64 +Connector_PinHeader_2.00mm +PinHeader_2x33_P2.00mm_Horizontal +Through hole angled pin header, 2x33, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinHeader_2.00mm +PinHeader_2x33_P2.00mm_Vertical +Through hole straight pin header, 2x33, 2.00mm pitch, double rows +Through hole pin header THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinHeader_2.00mm +PinHeader_2x33_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x33 2.00mm double row +0 +66 +66 +Connector_PinHeader_2.00mm +PinHeader_2x34_P2.00mm_Horizontal +Through hole angled pin header, 2x34, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinHeader_2.00mm +PinHeader_2x34_P2.00mm_Vertical +Through hole straight pin header, 2x34, 2.00mm pitch, double rows +Through hole pin header THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinHeader_2.00mm +PinHeader_2x34_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x34 2.00mm double row +0 +68 +68 +Connector_PinHeader_2.00mm +PinHeader_2x35_P2.00mm_Horizontal +Through hole angled pin header, 2x35, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinHeader_2.00mm +PinHeader_2x35_P2.00mm_Vertical +Through hole straight pin header, 2x35, 2.00mm pitch, double rows +Through hole pin header THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinHeader_2.00mm +PinHeader_2x35_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x35 2.00mm double row +0 +70 +70 +Connector_PinHeader_2.00mm +PinHeader_2x36_P2.00mm_Horizontal +Through hole angled pin header, 2x36, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinHeader_2.00mm +PinHeader_2x36_P2.00mm_Vertical +Through hole straight pin header, 2x36, 2.00mm pitch, double rows +Through hole pin header THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinHeader_2.00mm +PinHeader_2x36_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x36 2.00mm double row +0 +72 +72 +Connector_PinHeader_2.00mm +PinHeader_2x37_P2.00mm_Horizontal +Through hole angled pin header, 2x37, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinHeader_2.00mm +PinHeader_2x37_P2.00mm_Vertical +Through hole straight pin header, 2x37, 2.00mm pitch, double rows +Through hole pin header THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinHeader_2.00mm +PinHeader_2x37_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x37 2.00mm double row +0 +74 +74 +Connector_PinHeader_2.00mm +PinHeader_2x38_P2.00mm_Horizontal +Through hole angled pin header, 2x38, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinHeader_2.00mm +PinHeader_2x38_P2.00mm_Vertical +Through hole straight pin header, 2x38, 2.00mm pitch, double rows +Through hole pin header THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinHeader_2.00mm +PinHeader_2x38_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x38 2.00mm double row +0 +76 +76 +Connector_PinHeader_2.00mm +PinHeader_2x39_P2.00mm_Horizontal +Through hole angled pin header, 2x39, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinHeader_2.00mm +PinHeader_2x39_P2.00mm_Vertical +Through hole straight pin header, 2x39, 2.00mm pitch, double rows +Through hole pin header THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinHeader_2.00mm +PinHeader_2x39_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x39 2.00mm double row +0 +78 +78 +Connector_PinHeader_2.00mm +PinHeader_2x40_P2.00mm_Horizontal +Through hole angled pin header, 2x40, 2.00mm pitch, 4.2mm pin length, double rows +Through hole angled pin header THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinHeader_2.00mm +PinHeader_2x40_P2.00mm_Vertical +Through hole straight pin header, 2x40, 2.00mm pitch, double rows +Through hole pin header THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinHeader_2.00mm +PinHeader_2x40_P2.00mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 2.00mm pitch, double rows +Surface mounted pin header SMD 2x40 2.00mm double row +0 +80 +80 +Connector_PinHeader_2.54mm +PinHeader_1x01_P2.54mm_Horizontal +Through hole angled pin header, 1x01, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinHeader_2.54mm +PinHeader_1x01_P2.54mm_Vertical +Through hole straight pin header, 1x01, 2.54mm pitch, single row +Through hole pin header THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Horizontal +Through hole angled pin header, 1x02, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Vertical +Through hole straight pin header, 1x02, 2.54mm pitch, single row +Through hole pin header THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x02, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x02 2.54mm single row style1 pin1 left +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x02_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x02, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x02 2.54mm single row style2 pin1 right +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Horizontal +Through hole angled pin header, 1x03, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Vertical +Through hole straight pin header, 1x03, 2.54mm pitch, single row +Through hole pin header THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x03, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x03 2.54mm single row style1 pin1 left +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x03_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x03, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x03 2.54mm single row style2 pin1 right +0 +3 +3 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Horizontal +Through hole angled pin header, 1x04, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Vertical +Through hole straight pin header, 1x04, 2.54mm pitch, single row +Through hole pin header THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x04, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x04 2.54mm single row style1 pin1 left +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x04_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x04, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x04 2.54mm single row style2 pin1 right +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Horizontal +Through hole angled pin header, 1x05, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Vertical +Through hole straight pin header, 1x05, 2.54mm pitch, single row +Through hole pin header THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x05, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x05 2.54mm single row style1 pin1 left +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x05_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x05, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x05 2.54mm single row style2 pin1 right +0 +5 +5 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Horizontal +Through hole angled pin header, 1x06, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Vertical +Through hole straight pin header, 1x06, 2.54mm pitch, single row +Through hole pin header THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x06, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x06 2.54mm single row style1 pin1 left +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x06_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x06, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x06 2.54mm single row style2 pin1 right +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Horizontal +Through hole angled pin header, 1x07, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Vertical +Through hole straight pin header, 1x07, 2.54mm pitch, single row +Through hole pin header THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x07, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x07 2.54mm single row style1 pin1 left +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x07_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x07, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x07 2.54mm single row style2 pin1 right +0 +7 +7 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Horizontal +Through hole angled pin header, 1x08, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Vertical +Through hole straight pin header, 1x08, 2.54mm pitch, single row +Through hole pin header THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x08, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x08 2.54mm single row style1 pin1 left +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x08_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x08, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x08 2.54mm single row style2 pin1 right +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Horizontal +Through hole angled pin header, 1x09, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Vertical +Through hole straight pin header, 1x09, 2.54mm pitch, single row +Through hole pin header THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x09, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x09 2.54mm single row style1 pin1 left +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x09_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x09, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x09 2.54mm single row style2 pin1 right +0 +9 +9 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Horizontal +Through hole angled pin header, 1x10, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Vertical +Through hole straight pin header, 1x10, 2.54mm pitch, single row +Through hole pin header THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x10, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x10 2.54mm single row style1 pin1 left +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x10_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x10, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x10 2.54mm single row style2 pin1 right +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Horizontal +Through hole angled pin header, 1x11, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Vertical +Through hole straight pin header, 1x11, 2.54mm pitch, single row +Through hole pin header THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x11, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x11 2.54mm single row style1 pin1 left +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x11_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x11, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x11 2.54mm single row style2 pin1 right +0 +11 +11 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Horizontal +Through hole angled pin header, 1x12, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Vertical +Through hole straight pin header, 1x12, 2.54mm pitch, single row +Through hole pin header THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x12, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x12 2.54mm single row style1 pin1 left +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x12_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x12, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x12 2.54mm single row style2 pin1 right +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Horizontal +Through hole angled pin header, 1x13, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Vertical +Through hole straight pin header, 1x13, 2.54mm pitch, single row +Through hole pin header THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x13, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x13 2.54mm single row style1 pin1 left +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x13_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x13, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x13 2.54mm single row style2 pin1 right +0 +13 +13 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Horizontal +Through hole angled pin header, 1x14, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Vertical +Through hole straight pin header, 1x14, 2.54mm pitch, single row +Through hole pin header THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x14, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x14 2.54mm single row style1 pin1 left +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x14_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x14, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x14 2.54mm single row style2 pin1 right +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Horizontal +Through hole angled pin header, 1x15, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Vertical +Through hole straight pin header, 1x15, 2.54mm pitch, single row +Through hole pin header THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x15, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x15 2.54mm single row style1 pin1 left +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x15_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x15, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x15 2.54mm single row style2 pin1 right +0 +15 +15 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Horizontal +Through hole angled pin header, 1x16, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Vertical +Through hole straight pin header, 1x16, 2.54mm pitch, single row +Through hole pin header THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x16, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x16 2.54mm single row style1 pin1 left +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x16_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x16, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x16 2.54mm single row style2 pin1 right +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Horizontal +Through hole angled pin header, 1x17, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Vertical +Through hole straight pin header, 1x17, 2.54mm pitch, single row +Through hole pin header THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x17, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x17 2.54mm single row style1 pin1 left +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x17_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x17, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x17 2.54mm single row style2 pin1 right +0 +17 +17 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Horizontal +Through hole angled pin header, 1x18, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Vertical +Through hole straight pin header, 1x18, 2.54mm pitch, single row +Through hole pin header THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x18, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x18 2.54mm single row style1 pin1 left +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x18_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x18, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x18 2.54mm single row style2 pin1 right +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Horizontal +Through hole angled pin header, 1x19, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Vertical +Through hole straight pin header, 1x19, 2.54mm pitch, single row +Through hole pin header THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x19, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x19 2.54mm single row style1 pin1 left +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x19_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x19, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x19 2.54mm single row style2 pin1 right +0 +19 +19 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Horizontal +Through hole angled pin header, 1x20, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Vertical +Through hole straight pin header, 1x20, 2.54mm pitch, single row +Through hole pin header THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x20, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x20 2.54mm single row style1 pin1 left +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x20_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x20, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x20 2.54mm single row style2 pin1 right +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Horizontal +Through hole angled pin header, 1x21, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Vertical +Through hole straight pin header, 1x21, 2.54mm pitch, single row +Through hole pin header THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x21, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x21 2.54mm single row style1 pin1 left +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x21_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x21, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x21 2.54mm single row style2 pin1 right +0 +21 +21 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Horizontal +Through hole angled pin header, 1x22, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Vertical +Through hole straight pin header, 1x22, 2.54mm pitch, single row +Through hole pin header THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x22, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x22 2.54mm single row style1 pin1 left +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x22_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x22, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x22 2.54mm single row style2 pin1 right +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Horizontal +Through hole angled pin header, 1x23, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Vertical +Through hole straight pin header, 1x23, 2.54mm pitch, single row +Through hole pin header THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x23, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x23 2.54mm single row style1 pin1 left +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x23_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x23, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x23 2.54mm single row style2 pin1 right +0 +23 +23 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Horizontal +Through hole angled pin header, 1x24, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Vertical +Through hole straight pin header, 1x24, 2.54mm pitch, single row +Through hole pin header THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x24, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x24 2.54mm single row style1 pin1 left +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x24_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x24, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x24 2.54mm single row style2 pin1 right +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Horizontal +Through hole angled pin header, 1x25, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Vertical +Through hole straight pin header, 1x25, 2.54mm pitch, single row +Through hole pin header THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x25, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x25 2.54mm single row style1 pin1 left +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x25_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x25, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x25 2.54mm single row style2 pin1 right +0 +25 +25 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Horizontal +Through hole angled pin header, 1x26, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Vertical +Through hole straight pin header, 1x26, 2.54mm pitch, single row +Through hole pin header THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x26, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x26 2.54mm single row style1 pin1 left +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x26_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x26, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x26 2.54mm single row style2 pin1 right +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Horizontal +Through hole angled pin header, 1x27, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Vertical +Through hole straight pin header, 1x27, 2.54mm pitch, single row +Through hole pin header THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x27, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x27 2.54mm single row style1 pin1 left +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x27_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x27, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x27 2.54mm single row style2 pin1 right +0 +27 +27 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Horizontal +Through hole angled pin header, 1x28, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Vertical +Through hole straight pin header, 1x28, 2.54mm pitch, single row +Through hole pin header THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x28, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x28 2.54mm single row style1 pin1 left +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x28_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x28, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x28 2.54mm single row style2 pin1 right +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Horizontal +Through hole angled pin header, 1x29, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Vertical +Through hole straight pin header, 1x29, 2.54mm pitch, single row +Through hole pin header THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x29, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x29 2.54mm single row style1 pin1 left +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x29_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x29, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x29 2.54mm single row style2 pin1 right +0 +29 +29 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Horizontal +Through hole angled pin header, 1x30, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Vertical +Through hole straight pin header, 1x30, 2.54mm pitch, single row +Through hole pin header THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x30, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x30 2.54mm single row style1 pin1 left +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x30_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x30, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x30 2.54mm single row style2 pin1 right +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Horizontal +Through hole angled pin header, 1x31, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Vertical +Through hole straight pin header, 1x31, 2.54mm pitch, single row +Through hole pin header THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x31, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x31 2.54mm single row style1 pin1 left +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x31_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x31, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x31 2.54mm single row style2 pin1 right +0 +31 +31 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Horizontal +Through hole angled pin header, 1x32, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Vertical +Through hole straight pin header, 1x32, 2.54mm pitch, single row +Through hole pin header THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x32, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x32 2.54mm single row style1 pin1 left +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x32_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x32, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x32 2.54mm single row style2 pin1 right +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Horizontal +Through hole angled pin header, 1x33, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Vertical +Through hole straight pin header, 1x33, 2.54mm pitch, single row +Through hole pin header THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x33, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x33 2.54mm single row style1 pin1 left +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x33_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x33, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x33 2.54mm single row style2 pin1 right +0 +33 +33 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Horizontal +Through hole angled pin header, 1x34, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Vertical +Through hole straight pin header, 1x34, 2.54mm pitch, single row +Through hole pin header THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x34, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x34 2.54mm single row style1 pin1 left +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x34_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x34, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x34 2.54mm single row style2 pin1 right +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Horizontal +Through hole angled pin header, 1x35, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Vertical +Through hole straight pin header, 1x35, 2.54mm pitch, single row +Through hole pin header THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x35, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x35 2.54mm single row style1 pin1 left +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x35_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x35, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x35 2.54mm single row style2 pin1 right +0 +35 +35 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Horizontal +Through hole angled pin header, 1x36, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Vertical +Through hole straight pin header, 1x36, 2.54mm pitch, single row +Through hole pin header THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x36, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x36 2.54mm single row style1 pin1 left +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x36_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x36, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x36 2.54mm single row style2 pin1 right +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Horizontal +Through hole angled pin header, 1x37, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Vertical +Through hole straight pin header, 1x37, 2.54mm pitch, single row +Through hole pin header THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x37, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x37 2.54mm single row style1 pin1 left +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x37_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x37, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x37 2.54mm single row style2 pin1 right +0 +37 +37 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Horizontal +Through hole angled pin header, 1x38, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Vertical +Through hole straight pin header, 1x38, 2.54mm pitch, single row +Through hole pin header THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x38, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x38 2.54mm single row style1 pin1 left +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x38_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x38, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x38 2.54mm single row style2 pin1 right +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Horizontal +Through hole angled pin header, 1x39, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Vertical +Through hole straight pin header, 1x39, 2.54mm pitch, single row +Through hole pin header THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x39, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x39 2.54mm single row style1 pin1 left +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x39_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x39, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x39 2.54mm single row style2 pin1 right +0 +39 +39 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Horizontal +Through hole angled pin header, 1x40, 2.54mm pitch, 6mm pin length, single row +Through hole angled pin header THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Vertical +Through hole straight pin header, 1x40, 2.54mm pitch, single row +Through hole pin header THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight pin header, 1x40, 2.54mm pitch, single row, style 1 (pin 1 left) +Surface mounted pin header SMD 1x40 2.54mm single row style1 pin1 left +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_1x40_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight pin header, 1x40, 2.54mm pitch, single row, style 2 (pin 1 right) +Surface mounted pin header SMD 1x40 2.54mm single row style2 pin1 right +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x01_P2.54mm_Horizontal +Through hole angled pin header, 2x01, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_2x01_P2.54mm_Vertical +Through hole straight pin header, 2x01, 2.54mm pitch, double rows +Through hole pin header THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_2x01_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x01, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x01 2.54mm double row +0 +2 +2 +Connector_PinHeader_2.54mm +PinHeader_2x02_P2.54mm_Horizontal +Through hole angled pin header, 2x02, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_2x02_P2.54mm_Vertical +Through hole straight pin header, 2x02, 2.54mm pitch, double rows +Through hole pin header THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_2x02_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x02, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x02 2.54mm double row +0 +4 +4 +Connector_PinHeader_2.54mm +PinHeader_2x03_P2.54mm_Horizontal +Through hole angled pin header, 2x03, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_2x03_P2.54mm_Vertical +Through hole straight pin header, 2x03, 2.54mm pitch, double rows +Through hole pin header THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_2x03_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x03, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x03 2.54mm double row +0 +6 +6 +Connector_PinHeader_2.54mm +PinHeader_2x04_P2.54mm_Horizontal +Through hole angled pin header, 2x04, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_2x04_P2.54mm_Vertical +Through hole straight pin header, 2x04, 2.54mm pitch, double rows +Through hole pin header THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_2x04_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x04, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x04 2.54mm double row +0 +8 +8 +Connector_PinHeader_2.54mm +PinHeader_2x05_P2.54mm_Horizontal +Through hole angled pin header, 2x05, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_2x05_P2.54mm_Vertical +Through hole straight pin header, 2x05, 2.54mm pitch, double rows +Through hole pin header THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_2x05_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x05, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x05 2.54mm double row +0 +10 +10 +Connector_PinHeader_2.54mm +PinHeader_2x06_P2.54mm_Horizontal +Through hole angled pin header, 2x06, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_2x06_P2.54mm_Vertical +Through hole straight pin header, 2x06, 2.54mm pitch, double rows +Through hole pin header THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_2x06_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x06, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x06 2.54mm double row +0 +12 +12 +Connector_PinHeader_2.54mm +PinHeader_2x07_P2.54mm_Horizontal +Through hole angled pin header, 2x07, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_2x07_P2.54mm_Vertical +Through hole straight pin header, 2x07, 2.54mm pitch, double rows +Through hole pin header THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_2x07_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x07, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x07 2.54mm double row +0 +14 +14 +Connector_PinHeader_2.54mm +PinHeader_2x08_P2.54mm_Horizontal +Through hole angled pin header, 2x08, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_2x08_P2.54mm_Vertical +Through hole straight pin header, 2x08, 2.54mm pitch, double rows +Through hole pin header THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_2x08_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x08, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x08 2.54mm double row +0 +16 +16 +Connector_PinHeader_2.54mm +PinHeader_2x09_P2.54mm_Horizontal +Through hole angled pin header, 2x09, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_2x09_P2.54mm_Vertical +Through hole straight pin header, 2x09, 2.54mm pitch, double rows +Through hole pin header THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_2x09_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x09, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x09 2.54mm double row +0 +18 +18 +Connector_PinHeader_2.54mm +PinHeader_2x10_P2.54mm_Horizontal +Through hole angled pin header, 2x10, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_2x10_P2.54mm_Vertical +Through hole straight pin header, 2x10, 2.54mm pitch, double rows +Through hole pin header THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_2x10_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x10, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x10 2.54mm double row +0 +20 +20 +Connector_PinHeader_2.54mm +PinHeader_2x11_P2.54mm_Horizontal +Through hole angled pin header, 2x11, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_2x11_P2.54mm_Vertical +Through hole straight pin header, 2x11, 2.54mm pitch, double rows +Through hole pin header THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_2x11_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x11, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x11 2.54mm double row +0 +22 +22 +Connector_PinHeader_2.54mm +PinHeader_2x12_P2.54mm_Horizontal +Through hole angled pin header, 2x12, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_2x12_P2.54mm_Vertical +Through hole straight pin header, 2x12, 2.54mm pitch, double rows +Through hole pin header THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_2x12_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x12, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x12 2.54mm double row +0 +24 +24 +Connector_PinHeader_2.54mm +PinHeader_2x13_P2.54mm_Horizontal +Through hole angled pin header, 2x13, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_2x13_P2.54mm_Vertical +Through hole straight pin header, 2x13, 2.54mm pitch, double rows +Through hole pin header THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_2x13_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x13, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x13 2.54mm double row +0 +26 +26 +Connector_PinHeader_2.54mm +PinHeader_2x14_P2.54mm_Horizontal +Through hole angled pin header, 2x14, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_2x14_P2.54mm_Vertical +Through hole straight pin header, 2x14, 2.54mm pitch, double rows +Through hole pin header THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_2x14_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x14, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x14 2.54mm double row +0 +28 +28 +Connector_PinHeader_2.54mm +PinHeader_2x15_P2.54mm_Horizontal +Through hole angled pin header, 2x15, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_2x15_P2.54mm_Vertical +Through hole straight pin header, 2x15, 2.54mm pitch, double rows +Through hole pin header THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_2x15_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x15, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x15 2.54mm double row +0 +30 +30 +Connector_PinHeader_2.54mm +PinHeader_2x16_P2.54mm_Horizontal +Through hole angled pin header, 2x16, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_2x16_P2.54mm_Vertical +Through hole straight pin header, 2x16, 2.54mm pitch, double rows +Through hole pin header THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_2x16_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x16, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x16 2.54mm double row +0 +32 +32 +Connector_PinHeader_2.54mm +PinHeader_2x17_P2.54mm_Horizontal +Through hole angled pin header, 2x17, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_2x17_P2.54mm_Vertical +Through hole straight pin header, 2x17, 2.54mm pitch, double rows +Through hole pin header THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_2x17_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x17, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x17 2.54mm double row +0 +34 +34 +Connector_PinHeader_2.54mm +PinHeader_2x18_P2.54mm_Horizontal +Through hole angled pin header, 2x18, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_2x18_P2.54mm_Vertical +Through hole straight pin header, 2x18, 2.54mm pitch, double rows +Through hole pin header THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_2x18_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x18, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x18 2.54mm double row +0 +36 +36 +Connector_PinHeader_2.54mm +PinHeader_2x19_P2.54mm_Horizontal +Through hole angled pin header, 2x19, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_2x19_P2.54mm_Vertical +Through hole straight pin header, 2x19, 2.54mm pitch, double rows +Through hole pin header THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_2x19_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x19, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x19 2.54mm double row +0 +38 +38 +Connector_PinHeader_2.54mm +PinHeader_2x20_P2.54mm_Horizontal +Through hole angled pin header, 2x20, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x20_P2.54mm_Vertical +Through hole straight pin header, 2x20, 2.54mm pitch, double rows +Through hole pin header THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x20_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x20, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x20 2.54mm double row +0 +40 +40 +Connector_PinHeader_2.54mm +PinHeader_2x21_P2.54mm_Horizontal +Through hole angled pin header, 2x21, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinHeader_2.54mm +PinHeader_2x21_P2.54mm_Vertical +Through hole straight pin header, 2x21, 2.54mm pitch, double rows +Through hole pin header THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinHeader_2.54mm +PinHeader_2x21_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x21, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x21 2.54mm double row +0 +42 +42 +Connector_PinHeader_2.54mm +PinHeader_2x22_P2.54mm_Horizontal +Through hole angled pin header, 2x22, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinHeader_2.54mm +PinHeader_2x22_P2.54mm_Vertical +Through hole straight pin header, 2x22, 2.54mm pitch, double rows +Through hole pin header THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinHeader_2.54mm +PinHeader_2x22_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x22, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x22 2.54mm double row +0 +44 +44 +Connector_PinHeader_2.54mm +PinHeader_2x23_P2.54mm_Horizontal +Through hole angled pin header, 2x23, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinHeader_2.54mm +PinHeader_2x23_P2.54mm_Vertical +Through hole straight pin header, 2x23, 2.54mm pitch, double rows +Through hole pin header THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinHeader_2.54mm +PinHeader_2x23_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x23, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x23 2.54mm double row +0 +46 +46 +Connector_PinHeader_2.54mm +PinHeader_2x24_P2.54mm_Horizontal +Through hole angled pin header, 2x24, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinHeader_2.54mm +PinHeader_2x24_P2.54mm_Vertical +Through hole straight pin header, 2x24, 2.54mm pitch, double rows +Through hole pin header THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinHeader_2.54mm +PinHeader_2x24_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x24, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x24 2.54mm double row +0 +48 +48 +Connector_PinHeader_2.54mm +PinHeader_2x25_P2.54mm_Horizontal +Through hole angled pin header, 2x25, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinHeader_2.54mm +PinHeader_2x25_P2.54mm_Vertical +Through hole straight pin header, 2x25, 2.54mm pitch, double rows +Through hole pin header THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinHeader_2.54mm +PinHeader_2x25_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x25, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x25 2.54mm double row +0 +50 +50 +Connector_PinHeader_2.54mm +PinHeader_2x26_P2.54mm_Horizontal +Through hole angled pin header, 2x26, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinHeader_2.54mm +PinHeader_2x26_P2.54mm_Vertical +Through hole straight pin header, 2x26, 2.54mm pitch, double rows +Through hole pin header THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinHeader_2.54mm +PinHeader_2x26_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x26, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x26 2.54mm double row +0 +52 +52 +Connector_PinHeader_2.54mm +PinHeader_2x27_P2.54mm_Horizontal +Through hole angled pin header, 2x27, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinHeader_2.54mm +PinHeader_2x27_P2.54mm_Vertical +Through hole straight pin header, 2x27, 2.54mm pitch, double rows +Through hole pin header THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinHeader_2.54mm +PinHeader_2x27_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x27, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x27 2.54mm double row +0 +54 +54 +Connector_PinHeader_2.54mm +PinHeader_2x28_P2.54mm_Horizontal +Through hole angled pin header, 2x28, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinHeader_2.54mm +PinHeader_2x28_P2.54mm_Vertical +Through hole straight pin header, 2x28, 2.54mm pitch, double rows +Through hole pin header THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinHeader_2.54mm +PinHeader_2x28_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x28, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x28 2.54mm double row +0 +56 +56 +Connector_PinHeader_2.54mm +PinHeader_2x29_P2.54mm_Horizontal +Through hole angled pin header, 2x29, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinHeader_2.54mm +PinHeader_2x29_P2.54mm_Vertical +Through hole straight pin header, 2x29, 2.54mm pitch, double rows +Through hole pin header THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinHeader_2.54mm +PinHeader_2x29_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x29, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x29 2.54mm double row +0 +58 +58 +Connector_PinHeader_2.54mm +PinHeader_2x30_P2.54mm_Horizontal +Through hole angled pin header, 2x30, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinHeader_2.54mm +PinHeader_2x30_P2.54mm_Vertical +Through hole straight pin header, 2x30, 2.54mm pitch, double rows +Through hole pin header THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinHeader_2.54mm +PinHeader_2x30_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x30, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x30 2.54mm double row +0 +60 +60 +Connector_PinHeader_2.54mm +PinHeader_2x31_P2.54mm_Horizontal +Through hole angled pin header, 2x31, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinHeader_2.54mm +PinHeader_2x31_P2.54mm_Vertical +Through hole straight pin header, 2x31, 2.54mm pitch, double rows +Through hole pin header THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinHeader_2.54mm +PinHeader_2x31_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x31, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x31 2.54mm double row +0 +62 +62 +Connector_PinHeader_2.54mm +PinHeader_2x32_P2.54mm_Horizontal +Through hole angled pin header, 2x32, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinHeader_2.54mm +PinHeader_2x32_P2.54mm_Vertical +Through hole straight pin header, 2x32, 2.54mm pitch, double rows +Through hole pin header THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinHeader_2.54mm +PinHeader_2x32_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x32, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x32 2.54mm double row +0 +64 +64 +Connector_PinHeader_2.54mm +PinHeader_2x33_P2.54mm_Horizontal +Through hole angled pin header, 2x33, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinHeader_2.54mm +PinHeader_2x33_P2.54mm_Vertical +Through hole straight pin header, 2x33, 2.54mm pitch, double rows +Through hole pin header THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinHeader_2.54mm +PinHeader_2x33_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x33, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x33 2.54mm double row +0 +66 +66 +Connector_PinHeader_2.54mm +PinHeader_2x34_P2.54mm_Horizontal +Through hole angled pin header, 2x34, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinHeader_2.54mm +PinHeader_2x34_P2.54mm_Vertical +Through hole straight pin header, 2x34, 2.54mm pitch, double rows +Through hole pin header THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinHeader_2.54mm +PinHeader_2x34_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x34, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x34 2.54mm double row +0 +68 +68 +Connector_PinHeader_2.54mm +PinHeader_2x35_P2.54mm_Horizontal +Through hole angled pin header, 2x35, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinHeader_2.54mm +PinHeader_2x35_P2.54mm_Vertical +Through hole straight pin header, 2x35, 2.54mm pitch, double rows +Through hole pin header THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinHeader_2.54mm +PinHeader_2x35_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x35, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x35 2.54mm double row +0 +70 +70 +Connector_PinHeader_2.54mm +PinHeader_2x36_P2.54mm_Horizontal +Through hole angled pin header, 2x36, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinHeader_2.54mm +PinHeader_2x36_P2.54mm_Vertical +Through hole straight pin header, 2x36, 2.54mm pitch, double rows +Through hole pin header THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinHeader_2.54mm +PinHeader_2x36_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x36, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x36 2.54mm double row +0 +72 +72 +Connector_PinHeader_2.54mm +PinHeader_2x37_P2.54mm_Horizontal +Through hole angled pin header, 2x37, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinHeader_2.54mm +PinHeader_2x37_P2.54mm_Vertical +Through hole straight pin header, 2x37, 2.54mm pitch, double rows +Through hole pin header THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinHeader_2.54mm +PinHeader_2x37_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x37, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x37 2.54mm double row +0 +74 +74 +Connector_PinHeader_2.54mm +PinHeader_2x38_P2.54mm_Horizontal +Through hole angled pin header, 2x38, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinHeader_2.54mm +PinHeader_2x38_P2.54mm_Vertical +Through hole straight pin header, 2x38, 2.54mm pitch, double rows +Through hole pin header THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinHeader_2.54mm +PinHeader_2x38_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x38, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x38 2.54mm double row +0 +76 +76 +Connector_PinHeader_2.54mm +PinHeader_2x39_P2.54mm_Horizontal +Through hole angled pin header, 2x39, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinHeader_2.54mm +PinHeader_2x39_P2.54mm_Vertical +Through hole straight pin header, 2x39, 2.54mm pitch, double rows +Through hole pin header THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinHeader_2.54mm +PinHeader_2x39_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x39, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x39 2.54mm double row +0 +78 +78 +Connector_PinHeader_2.54mm +PinHeader_2x40_P2.54mm_Horizontal +Through hole angled pin header, 2x40, 2.54mm pitch, 6mm pin length, double rows +Through hole angled pin header THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinHeader_2.54mm +PinHeader_2x40_P2.54mm_Vertical +Through hole straight pin header, 2x40, 2.54mm pitch, double rows +Through hole pin header THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinHeader_2.54mm +PinHeader_2x40_P2.54mm_Vertical_SMD +surface-mounted straight pin header, 2x40, 2.54mm pitch, double rows +Surface mounted pin header SMD 2x40 2.54mm double row +0 +80 +80 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical +Through hole straight socket strip, 1x02, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x02 1.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x02 1.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical +Through hole straight socket strip, 1x03, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x03 1.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x03 1.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical +Through hole straight socket strip, 1x04, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x04 1.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x04 1.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical +Through hole straight socket strip, 1x05, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x05 1.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x05 1.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical +Through hole straight socket strip, 1x06, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x06 1.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x06 1.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical +Through hole straight socket strip, 1x07, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x07 1.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x07 1.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical +Through hole straight socket strip, 1x08, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x08 1.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x08 1.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical +Through hole straight socket strip, 1x09, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x09 1.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x09 1.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical +Through hole straight socket strip, 1x10, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x10 1.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x10 1.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical +Through hole straight socket strip, 1x11, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x11 1.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x11 1.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical +Through hole straight socket strip, 1x12, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x12 1.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x12 1.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical +Through hole straight socket strip, 1x13, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x13 1.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x13 1.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical +Through hole straight socket strip, 1x14, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x14 1.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x14 1.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical +Through hole straight socket strip, 1x15, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x15 1.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x15 1.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical +Through hole straight socket strip, 1x16, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x16 1.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x16 1.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical +Through hole straight socket strip, 1x17, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x17 1.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x17 1.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical +Through hole straight socket strip, 1x18, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x18 1.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x18 1.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical +Through hole straight socket strip, 1x19, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x19 1.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x19 1.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical +Through hole straight socket strip, 1x20, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x20 1.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x20 1.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical +Through hole straight socket strip, 1x21, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x21 1.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x21 1.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical +Through hole straight socket strip, 1x22, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x22 1.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x22 1.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical +Through hole straight socket strip, 1x23, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x23 1.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x23 1.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical +Through hole straight socket strip, 1x24, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x24 1.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x24 1.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical +Through hole straight socket strip, 1x25, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x25 1.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x25 1.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical +Through hole straight socket strip, 1x26, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x26 1.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x26 1.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical +Through hole straight socket strip, 1x27, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x27 1.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x27 1.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical +Through hole straight socket strip, 1x28, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x28 1.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x28 1.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical +Through hole straight socket strip, 1x29, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x29 1.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x29 1.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical +Through hole straight socket strip, 1x30, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x30 1.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x30 1.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical +Through hole straight socket strip, 1x31, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x31 1.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x31 1.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical +Through hole straight socket strip, 1x32, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x32 1.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x32 1.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical +Through hole straight socket strip, 1x33, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x33 1.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x33 1.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical +Through hole straight socket strip, 1x34, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x34 1.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x34 1.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical +Through hole straight socket strip, 1x35, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x35 1.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x35 1.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical +Through hole straight socket strip, 1x36, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x36 1.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x36 1.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical +Through hole straight socket strip, 1x37, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x37 1.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x37 1.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical +Through hole straight socket strip, 1x38, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x38 1.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x38 1.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical +Through hole straight socket strip, 1x39, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x39 1.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x39 1.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical +Through hole straight socket strip, 1x40, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x40 1.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x40 1.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_2x02_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x02 1.00mm double row +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_2x03_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x03 1.00mm double row +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_2x04_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x04 1.00mm double row +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_2x05_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x05 1.00mm double row +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_2x06_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x06 1.00mm double row +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_2x07_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x07 1.00mm double row +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_2x08_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x08 1.00mm double row +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_2x09_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x09 1.00mm double row +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_2x10_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x10 1.00mm double row +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_2x11_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x11 1.00mm double row +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_2x12_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x12 1.00mm double row +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_2x13_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x13 1.00mm double row +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_2x14_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x14 1.00mm double row +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_2x15_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x15 1.00mm double row +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_2x16_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x16 1.00mm double row +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_2x17_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x17 1.00mm double row +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_2x18_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x18 1.00mm double row +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_2x19_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x19 1.00mm double row +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_2x20_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x20 1.00mm double row +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_2x21_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x21 1.00mm double row +0 +42 +42 +Connector_PinSocket_1.00mm +PinSocket_2x22_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x22 1.00mm double row +0 +44 +44 +Connector_PinSocket_1.00mm +PinSocket_2x23_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x23 1.00mm double row +0 +46 +46 +Connector_PinSocket_1.00mm +PinSocket_2x24_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x24 1.00mm double row +0 +48 +48 +Connector_PinSocket_1.00mm +PinSocket_2x25_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x25 1.00mm double row +0 +50 +50 +Connector_PinSocket_1.00mm +PinSocket_2x26_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x26 1.00mm double row +0 +52 +52 +Connector_PinSocket_1.00mm +PinSocket_2x27_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x27 1.00mm double row +0 +54 +54 +Connector_PinSocket_1.00mm +PinSocket_2x28_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x28 1.00mm double row +0 +56 +56 +Connector_PinSocket_1.00mm +PinSocket_2x29_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x29 1.00mm double row +0 +58 +58 +Connector_PinSocket_1.00mm +PinSocket_2x30_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x30 1.00mm double row +0 +60 +60 +Connector_PinSocket_1.00mm +PinSocket_2x31_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x31 1.00mm double row +0 +62 +62 +Connector_PinSocket_1.00mm +PinSocket_2x32_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x32 1.00mm double row +0 +64 +64 +Connector_PinSocket_1.00mm +PinSocket_2x33_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x33 1.00mm double row +0 +66 +66 +Connector_PinSocket_1.00mm +PinSocket_2x34_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x34 1.00mm double row +0 +68 +68 +Connector_PinSocket_1.00mm +PinSocket_2x35_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x35 1.00mm double row +0 +70 +70 +Connector_PinSocket_1.00mm +PinSocket_2x36_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x36 1.00mm double row +0 +72 +72 +Connector_PinSocket_1.00mm +PinSocket_2x37_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x37 1.00mm double row +0 +74 +74 +Connector_PinSocket_1.00mm +PinSocket_2x38_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x38 1.00mm double row +0 +76 +76 +Connector_PinSocket_1.00mm +PinSocket_2x39_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x39 1.00mm double row +0 +78 +78 +Connector_PinSocket_1.00mm +PinSocket_2x40_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x40 1.00mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_1x01_P1.27mm_Vertical +Through hole straight socket strip, 1x01, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x01 1.27mm single row +0 +1 +1 +Connector_PinSocket_1.27mm +PinSocket_1x02_P1.27mm_Vertical +Through hole straight socket strip, 1x02, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x02 1.27mm single row +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_1x02_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x02 1.27mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_1x02_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x02 1.27mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_1x03_P1.27mm_Vertical +Through hole straight socket strip, 1x03, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x03 1.27mm single row +0 +3 +3 +Connector_PinSocket_1.27mm +PinSocket_1x03_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x03 1.27mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_1.27mm +PinSocket_1x03_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x03 1.27mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_1.27mm +PinSocket_1x04_P1.27mm_Vertical +Through hole straight socket strip, 1x04, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x04 1.27mm single row +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_1x04_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x04 1.27mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_1x04_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x04 1.27mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_1x05_P1.27mm_Vertical +Through hole straight socket strip, 1x05, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x05 1.27mm single row +0 +5 +5 +Connector_PinSocket_1.27mm +PinSocket_1x05_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x05 1.27mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_1.27mm +PinSocket_1x05_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x05 1.27mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_1.27mm +PinSocket_1x06_P1.27mm_Vertical +Through hole straight socket strip, 1x06, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x06 1.27mm single row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_1x06_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x06 1.27mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_1x06_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x06 1.27mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_1x07_P1.27mm_Vertical +Through hole straight socket strip, 1x07, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x07 1.27mm single row +0 +7 +7 +Connector_PinSocket_1.27mm +PinSocket_1x07_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x07 1.27mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_1.27mm +PinSocket_1x07_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x07 1.27mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_1.27mm +PinSocket_1x08_P1.27mm_Vertical +Through hole straight socket strip, 1x08, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x08 1.27mm single row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_1x08_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x08 1.27mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_1x08_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x08 1.27mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_1x09_P1.27mm_Vertical +Through hole straight socket strip, 1x09, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x09 1.27mm single row +0 +9 +9 +Connector_PinSocket_1.27mm +PinSocket_1x09_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x09 1.27mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_1.27mm +PinSocket_1x09_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x09 1.27mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_1.27mm +PinSocket_1x10_P1.27mm_Vertical +Through hole straight socket strip, 1x10, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x10 1.27mm single row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_1x10_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x10 1.27mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_1x10_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x10 1.27mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_1x11_P1.27mm_Vertical +Through hole straight socket strip, 1x11, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x11 1.27mm single row +0 +11 +11 +Connector_PinSocket_1.27mm +PinSocket_1x11_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x11 1.27mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_1.27mm +PinSocket_1x11_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x11 1.27mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_1.27mm +PinSocket_1x12_P1.27mm_Vertical +Through hole straight socket strip, 1x12, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x12 1.27mm single row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_1x12_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x12 1.27mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_1x12_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x12 1.27mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_1x13_P1.27mm_Vertical +Through hole straight socket strip, 1x13, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x13 1.27mm single row +0 +13 +13 +Connector_PinSocket_1.27mm +PinSocket_1x13_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x13 1.27mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_1.27mm +PinSocket_1x13_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x13 1.27mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_1.27mm +PinSocket_1x14_P1.27mm_Vertical +Through hole straight socket strip, 1x14, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x14 1.27mm single row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_1x14_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x14 1.27mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_1x14_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x14 1.27mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_1x15_P1.27mm_Vertical +Through hole straight socket strip, 1x15, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x15 1.27mm single row +0 +15 +15 +Connector_PinSocket_1.27mm +PinSocket_1x15_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x15 1.27mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_1.27mm +PinSocket_1x15_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x15 1.27mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_1.27mm +PinSocket_1x16_P1.27mm_Vertical +Through hole straight socket strip, 1x16, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x16 1.27mm single row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_1x16_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x16 1.27mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_1x16_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x16 1.27mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_1x17_P1.27mm_Vertical +Through hole straight socket strip, 1x17, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x17 1.27mm single row +0 +17 +17 +Connector_PinSocket_1.27mm +PinSocket_1x17_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x17 1.27mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_1.27mm +PinSocket_1x17_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x17 1.27mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_1.27mm +PinSocket_1x18_P1.27mm_Vertical +Through hole straight socket strip, 1x18, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x18 1.27mm single row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_1x18_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x18 1.27mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_1x18_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x18 1.27mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_1x19_P1.27mm_Vertical +Through hole straight socket strip, 1x19, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x19 1.27mm single row +0 +19 +19 +Connector_PinSocket_1.27mm +PinSocket_1x19_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x19 1.27mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_1.27mm +PinSocket_1x19_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x19 1.27mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_1.27mm +PinSocket_1x20_P1.27mm_Vertical +Through hole straight socket strip, 1x20, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x20 1.27mm single row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_1x20_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x20 1.27mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_1x20_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x20 1.27mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_1x21_P1.27mm_Vertical +Through hole straight socket strip, 1x21, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x21 1.27mm single row +0 +21 +21 +Connector_PinSocket_1.27mm +PinSocket_1x21_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x21 1.27mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_1.27mm +PinSocket_1x21_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x21 1.27mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_1.27mm +PinSocket_1x22_P1.27mm_Vertical +Through hole straight socket strip, 1x22, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x22 1.27mm single row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_1x22_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x22 1.27mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_1x22_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x22 1.27mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_1x23_P1.27mm_Vertical +Through hole straight socket strip, 1x23, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x23 1.27mm single row +0 +23 +23 +Connector_PinSocket_1.27mm +PinSocket_1x23_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x23 1.27mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_1.27mm +PinSocket_1x23_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x23 1.27mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_1.27mm +PinSocket_1x24_P1.27mm_Vertical +Through hole straight socket strip, 1x24, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x24 1.27mm single row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_1x24_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x24 1.27mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_1x24_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x24 1.27mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_1x25_P1.27mm_Vertical +Through hole straight socket strip, 1x25, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x25 1.27mm single row +0 +25 +25 +Connector_PinSocket_1.27mm +PinSocket_1x25_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x25 1.27mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_1.27mm +PinSocket_1x25_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x25 1.27mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_1.27mm +PinSocket_1x26_P1.27mm_Vertical +Through hole straight socket strip, 1x26, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x26 1.27mm single row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_1x26_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x26 1.27mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_1x26_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x26 1.27mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_1x27_P1.27mm_Vertical +Through hole straight socket strip, 1x27, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x27 1.27mm single row +0 +27 +27 +Connector_PinSocket_1.27mm +PinSocket_1x27_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x27 1.27mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_1.27mm +PinSocket_1x27_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x27 1.27mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_1.27mm +PinSocket_1x28_P1.27mm_Vertical +Through hole straight socket strip, 1x28, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x28 1.27mm single row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_1x28_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x28 1.27mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_1x28_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x28 1.27mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_1x29_P1.27mm_Vertical +Through hole straight socket strip, 1x29, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x29 1.27mm single row +0 +29 +29 +Connector_PinSocket_1.27mm +PinSocket_1x29_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x29 1.27mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_1.27mm +PinSocket_1x29_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x29 1.27mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_1.27mm +PinSocket_1x30_P1.27mm_Vertical +Through hole straight socket strip, 1x30, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x30 1.27mm single row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_1x30_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x30 1.27mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_1x30_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x30 1.27mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_1x31_P1.27mm_Vertical +Through hole straight socket strip, 1x31, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x31 1.27mm single row +0 +31 +31 +Connector_PinSocket_1.27mm +PinSocket_1x31_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x31 1.27mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_1.27mm +PinSocket_1x31_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x31 1.27mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_1.27mm +PinSocket_1x32_P1.27mm_Vertical +Through hole straight socket strip, 1x32, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x32 1.27mm single row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_1x32_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x32 1.27mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_1x32_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x32 1.27mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_1x33_P1.27mm_Vertical +Through hole straight socket strip, 1x33, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x33 1.27mm single row +0 +33 +33 +Connector_PinSocket_1.27mm +PinSocket_1x33_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x33 1.27mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_1.27mm +PinSocket_1x33_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x33 1.27mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_1.27mm +PinSocket_1x34_P1.27mm_Vertical +Through hole straight socket strip, 1x34, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x34 1.27mm single row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_1x34_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x34 1.27mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_1x34_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x34 1.27mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_1x35_P1.27mm_Vertical +Through hole straight socket strip, 1x35, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x35 1.27mm single row +0 +35 +35 +Connector_PinSocket_1.27mm +PinSocket_1x35_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x35 1.27mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_1.27mm +PinSocket_1x35_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x35 1.27mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_1.27mm +PinSocket_1x36_P1.27mm_Vertical +Through hole straight socket strip, 1x36, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x36 1.27mm single row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_1x36_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x36 1.27mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_1x36_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x36 1.27mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_1x37_P1.27mm_Vertical +Through hole straight socket strip, 1x37, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x37 1.27mm single row +0 +37 +37 +Connector_PinSocket_1.27mm +PinSocket_1x37_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x37 1.27mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_1.27mm +PinSocket_1x37_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x37 1.27mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_1.27mm +PinSocket_1x38_P1.27mm_Vertical +Through hole straight socket strip, 1x38, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x38 1.27mm single row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_1x38_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x38 1.27mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_1x38_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x38 1.27mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_1x39_P1.27mm_Vertical +Through hole straight socket strip, 1x39, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x39 1.27mm single row +0 +39 +39 +Connector_PinSocket_1.27mm +PinSocket_1x39_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x39 1.27mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_1.27mm +PinSocket_1x39_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x39 1.27mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_1.27mm +PinSocket_1x40_P1.27mm_Vertical +Through hole straight socket strip, 1x40, 1.27mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x40 1.27mm single row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_1x40_P1.27mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 1.27mm pitch, single row, style 1 (pin 1 left) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x40 1.27mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_1x40_P1.27mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 1.27mm pitch, single row, style 2 (pin 1 right) (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD075.pdf&t=1511594726925), script generated +Surface mounted socket strip SMD 1x40 1.27mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x01_P1.27mm_Vertical +Through hole straight socket strip, 2x01, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x01 1.27mm double row +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_2x01_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x01, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x01 1.27mm double row +0 +2 +2 +Connector_PinSocket_1.27mm +PinSocket_2x02_P1.27mm_Vertical +Through hole straight socket strip, 2x02, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x02 1.27mm double row +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_2x02_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x02 1.27mm double row +0 +4 +4 +Connector_PinSocket_1.27mm +PinSocket_2x03_P1.27mm_Horizontal +Through hole angled socket strip, 2x03, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_2x03_P1.27mm_Vertical +Through hole straight socket strip, 2x03, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x03 1.27mm double row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_2x03_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x03 1.27mm double row +0 +6 +6 +Connector_PinSocket_1.27mm +PinSocket_2x04_P1.27mm_Horizontal +Through hole angled socket strip, 2x04, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_2x04_P1.27mm_Vertical +Through hole straight socket strip, 2x04, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x04 1.27mm double row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_2x04_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x04 1.27mm double row +0 +8 +8 +Connector_PinSocket_1.27mm +PinSocket_2x05_P1.27mm_Horizontal +Through hole angled socket strip, 2x05, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_2x05_P1.27mm_Vertical +Through hole straight socket strip, 2x05, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x05 1.27mm double row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_2x05_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x05 1.27mm double row +0 +10 +10 +Connector_PinSocket_1.27mm +PinSocket_2x06_P1.27mm_Horizontal +Through hole angled socket strip, 2x06, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_2x06_P1.27mm_Vertical +Through hole straight socket strip, 2x06, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x06 1.27mm double row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_2x06_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x06 1.27mm double row +0 +12 +12 +Connector_PinSocket_1.27mm +PinSocket_2x07_P1.27mm_Horizontal +Through hole angled socket strip, 2x07, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_2x07_P1.27mm_Vertical +Through hole straight socket strip, 2x07, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x07 1.27mm double row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_2x07_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x07 1.27mm double row +0 +14 +14 +Connector_PinSocket_1.27mm +PinSocket_2x08_P1.27mm_Horizontal +Through hole angled socket strip, 2x08, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_2x08_P1.27mm_Vertical +Through hole straight socket strip, 2x08, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x08 1.27mm double row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_2x08_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x08 1.27mm double row +0 +16 +16 +Connector_PinSocket_1.27mm +PinSocket_2x09_P1.27mm_Horizontal +Through hole angled socket strip, 2x09, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_2x09_P1.27mm_Vertical +Through hole straight socket strip, 2x09, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x09 1.27mm double row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_2x09_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x09 1.27mm double row +0 +18 +18 +Connector_PinSocket_1.27mm +PinSocket_2x10_P1.27mm_Horizontal +Through hole angled socket strip, 2x10, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_2x10_P1.27mm_Vertical +Through hole straight socket strip, 2x10, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x10 1.27mm double row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_2x10_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x10 1.27mm double row +0 +20 +20 +Connector_PinSocket_1.27mm +PinSocket_2x11_P1.27mm_Horizontal +Through hole angled socket strip, 2x11, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_2x11_P1.27mm_Vertical +Through hole straight socket strip, 2x11, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x11 1.27mm double row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_2x11_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x11 1.27mm double row +0 +22 +22 +Connector_PinSocket_1.27mm +PinSocket_2x12_P1.27mm_Horizontal +Through hole angled socket strip, 2x12, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_2x12_P1.27mm_Vertical +Through hole straight socket strip, 2x12, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x12 1.27mm double row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_2x12_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x12 1.27mm double row +0 +24 +24 +Connector_PinSocket_1.27mm +PinSocket_2x13_P1.27mm_Horizontal +Through hole angled socket strip, 2x13, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_2x13_P1.27mm_Vertical +Through hole straight socket strip, 2x13, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x13 1.27mm double row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_2x13_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x13 1.27mm double row +0 +26 +26 +Connector_PinSocket_1.27mm +PinSocket_2x14_P1.27mm_Horizontal +Through hole angled socket strip, 2x14, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_2x14_P1.27mm_Vertical +Through hole straight socket strip, 2x14, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x14 1.27mm double row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_2x14_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x14 1.27mm double row +0 +28 +28 +Connector_PinSocket_1.27mm +PinSocket_2x15_P1.27mm_Horizontal +Through hole angled socket strip, 2x15, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_2x15_P1.27mm_Vertical +Through hole straight socket strip, 2x15, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x15 1.27mm double row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_2x15_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x15 1.27mm double row +0 +30 +30 +Connector_PinSocket_1.27mm +PinSocket_2x16_P1.27mm_Horizontal +Through hole angled socket strip, 2x16, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_2x16_P1.27mm_Vertical +Through hole straight socket strip, 2x16, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x16 1.27mm double row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_2x16_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x16 1.27mm double row +0 +32 +32 +Connector_PinSocket_1.27mm +PinSocket_2x17_P1.27mm_Horizontal +Through hole angled socket strip, 2x17, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_2x17_P1.27mm_Vertical +Through hole straight socket strip, 2x17, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x17 1.27mm double row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_2x17_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x17 1.27mm double row +0 +34 +34 +Connector_PinSocket_1.27mm +PinSocket_2x18_P1.27mm_Horizontal +Through hole angled socket strip, 2x18, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_2x18_P1.27mm_Vertical +Through hole straight socket strip, 2x18, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x18 1.27mm double row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_2x18_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x18 1.27mm double row +0 +36 +36 +Connector_PinSocket_1.27mm +PinSocket_2x19_P1.27mm_Horizontal +Through hole angled socket strip, 2x19, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_2x19_P1.27mm_Vertical +Through hole straight socket strip, 2x19, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x19 1.27mm double row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_2x19_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x19 1.27mm double row +0 +38 +38 +Connector_PinSocket_1.27mm +PinSocket_2x20_P1.27mm_Horizontal +Through hole angled socket strip, 2x20, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x20_P1.27mm_Vertical +Through hole straight socket strip, 2x20, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x20 1.27mm double row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x20_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x20 1.27mm double row +0 +40 +40 +Connector_PinSocket_1.27mm +PinSocket_2x21_P1.27mm_Horizontal +Through hole angled socket strip, 2x21, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinSocket_1.27mm +PinSocket_2x21_P1.27mm_Vertical +Through hole straight socket strip, 2x21, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x21 1.27mm double row +0 +42 +42 +Connector_PinSocket_1.27mm +PinSocket_2x21_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x21 1.27mm double row +0 +42 +42 +Connector_PinSocket_1.27mm +PinSocket_2x22_P1.27mm_Horizontal +Through hole angled socket strip, 2x22, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinSocket_1.27mm +PinSocket_2x22_P1.27mm_Vertical +Through hole straight socket strip, 2x22, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x22 1.27mm double row +0 +44 +44 +Connector_PinSocket_1.27mm +PinSocket_2x22_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x22 1.27mm double row +0 +44 +44 +Connector_PinSocket_1.27mm +PinSocket_2x23_P1.27mm_Horizontal +Through hole angled socket strip, 2x23, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinSocket_1.27mm +PinSocket_2x23_P1.27mm_Vertical +Through hole straight socket strip, 2x23, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x23 1.27mm double row +0 +46 +46 +Connector_PinSocket_1.27mm +PinSocket_2x23_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x23 1.27mm double row +0 +46 +46 +Connector_PinSocket_1.27mm +PinSocket_2x24_P1.27mm_Horizontal +Through hole angled socket strip, 2x24, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinSocket_1.27mm +PinSocket_2x24_P1.27mm_Vertical +Through hole straight socket strip, 2x24, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x24 1.27mm double row +0 +48 +48 +Connector_PinSocket_1.27mm +PinSocket_2x24_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x24 1.27mm double row +0 +48 +48 +Connector_PinSocket_1.27mm +PinSocket_2x25_P1.27mm_Horizontal +Through hole angled socket strip, 2x25, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinSocket_1.27mm +PinSocket_2x25_P1.27mm_Vertical +Through hole straight socket strip, 2x25, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x25 1.27mm double row +0 +50 +50 +Connector_PinSocket_1.27mm +PinSocket_2x25_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x25 1.27mm double row +0 +50 +50 +Connector_PinSocket_1.27mm +PinSocket_2x26_P1.27mm_Horizontal +Through hole angled socket strip, 2x26, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinSocket_1.27mm +PinSocket_2x26_P1.27mm_Vertical +Through hole straight socket strip, 2x26, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x26 1.27mm double row +0 +52 +52 +Connector_PinSocket_1.27mm +PinSocket_2x26_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x26 1.27mm double row +0 +52 +52 +Connector_PinSocket_1.27mm +PinSocket_2x27_P1.27mm_Horizontal +Through hole angled socket strip, 2x27, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinSocket_1.27mm +PinSocket_2x27_P1.27mm_Vertical +Through hole straight socket strip, 2x27, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x27 1.27mm double row +0 +54 +54 +Connector_PinSocket_1.27mm +PinSocket_2x27_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x27 1.27mm double row +0 +54 +54 +Connector_PinSocket_1.27mm +PinSocket_2x28_P1.27mm_Horizontal +Through hole angled socket strip, 2x28, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinSocket_1.27mm +PinSocket_2x28_P1.27mm_Vertical +Through hole straight socket strip, 2x28, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x28 1.27mm double row +0 +56 +56 +Connector_PinSocket_1.27mm +PinSocket_2x28_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x28 1.27mm double row +0 +56 +56 +Connector_PinSocket_1.27mm +PinSocket_2x29_P1.27mm_Horizontal +Through hole angled socket strip, 2x29, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinSocket_1.27mm +PinSocket_2x29_P1.27mm_Vertical +Through hole straight socket strip, 2x29, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x29 1.27mm double row +0 +58 +58 +Connector_PinSocket_1.27mm +PinSocket_2x29_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x29 1.27mm double row +0 +58 +58 +Connector_PinSocket_1.27mm +PinSocket_2x30_P1.27mm_Horizontal +Through hole angled socket strip, 2x30, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinSocket_1.27mm +PinSocket_2x30_P1.27mm_Vertical +Through hole straight socket strip, 2x30, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x30 1.27mm double row +0 +60 +60 +Connector_PinSocket_1.27mm +PinSocket_2x30_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x30 1.27mm double row +0 +60 +60 +Connector_PinSocket_1.27mm +PinSocket_2x31_P1.27mm_Horizontal +Through hole angled socket strip, 2x31, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinSocket_1.27mm +PinSocket_2x31_P1.27mm_Vertical +Through hole straight socket strip, 2x31, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x31 1.27mm double row +0 +62 +62 +Connector_PinSocket_1.27mm +PinSocket_2x31_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x31 1.27mm double row +0 +62 +62 +Connector_PinSocket_1.27mm +PinSocket_2x32_P1.27mm_Horizontal +Through hole angled socket strip, 2x32, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinSocket_1.27mm +PinSocket_2x32_P1.27mm_Vertical +Through hole straight socket strip, 2x32, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x32 1.27mm double row +0 +64 +64 +Connector_PinSocket_1.27mm +PinSocket_2x32_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x32 1.27mm double row +0 +64 +64 +Connector_PinSocket_1.27mm +PinSocket_2x33_P1.27mm_Horizontal +Through hole angled socket strip, 2x33, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinSocket_1.27mm +PinSocket_2x33_P1.27mm_Vertical +Through hole straight socket strip, 2x33, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x33 1.27mm double row +0 +66 +66 +Connector_PinSocket_1.27mm +PinSocket_2x33_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x33 1.27mm double row +0 +66 +66 +Connector_PinSocket_1.27mm +PinSocket_2x34_P1.27mm_Horizontal +Through hole angled socket strip, 2x34, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinSocket_1.27mm +PinSocket_2x34_P1.27mm_Vertical +Through hole straight socket strip, 2x34, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x34 1.27mm double row +0 +68 +68 +Connector_PinSocket_1.27mm +PinSocket_2x34_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x34 1.27mm double row +0 +68 +68 +Connector_PinSocket_1.27mm +PinSocket_2x35_P1.27mm_Horizontal +Through hole angled socket strip, 2x35, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinSocket_1.27mm +PinSocket_2x35_P1.27mm_Vertical +Through hole straight socket strip, 2x35, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x35 1.27mm double row +0 +70 +70 +Connector_PinSocket_1.27mm +PinSocket_2x35_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x35 1.27mm double row +0 +70 +70 +Connector_PinSocket_1.27mm +PinSocket_2x36_P1.27mm_Horizontal +Through hole angled socket strip, 2x36, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinSocket_1.27mm +PinSocket_2x36_P1.27mm_Vertical +Through hole straight socket strip, 2x36, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x36 1.27mm double row +0 +72 +72 +Connector_PinSocket_1.27mm +PinSocket_2x36_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x36 1.27mm double row +0 +72 +72 +Connector_PinSocket_1.27mm +PinSocket_2x37_P1.27mm_Horizontal +Through hole angled socket strip, 2x37, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinSocket_1.27mm +PinSocket_2x37_P1.27mm_Vertical +Through hole straight socket strip, 2x37, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x37 1.27mm double row +0 +74 +74 +Connector_PinSocket_1.27mm +PinSocket_2x37_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x37 1.27mm double row +0 +74 +74 +Connector_PinSocket_1.27mm +PinSocket_2x38_P1.27mm_Horizontal +Through hole angled socket strip, 2x38, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinSocket_1.27mm +PinSocket_2x38_P1.27mm_Vertical +Through hole straight socket strip, 2x38, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x38 1.27mm double row +0 +76 +76 +Connector_PinSocket_1.27mm +PinSocket_2x38_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x38 1.27mm double row +0 +76 +76 +Connector_PinSocket_1.27mm +PinSocket_2x39_P1.27mm_Horizontal +Through hole angled socket strip, 2x39, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinSocket_1.27mm +PinSocket_2x39_P1.27mm_Vertical +Through hole straight socket strip, 2x39, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x39 1.27mm double row +0 +78 +78 +Connector_PinSocket_1.27mm +PinSocket_2x39_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x39 1.27mm double row +0 +78 +78 +Connector_PinSocket_1.27mm +PinSocket_2x40_P1.27mm_Horizontal +Through hole angled socket strip, 2x40, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_2x40_P1.27mm_Vertical +Through hole straight socket strip, 2x40, 1.27mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x40 1.27mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_2x40_P1.27mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 1.27mm pitch, double cols (from Kicad 4.0.7!), script generated +Surface mounted socket strip SMD 2x40 1.27mm double row +0 +80 +80 +Connector_PinSocket_1.27mm +PinSocket_2x41_P1.27mm_Horizontal +Through hole angled socket strip, 2x41, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x41 1.27mm double row +0 +82 +82 +Connector_PinSocket_1.27mm +PinSocket_2x42_P1.27mm_Horizontal +Through hole angled socket strip, 2x42, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x42 1.27mm double row +0 +84 +84 +Connector_PinSocket_1.27mm +PinSocket_2x43_P1.27mm_Horizontal +Through hole angled socket strip, 2x43, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x43 1.27mm double row +0 +86 +86 +Connector_PinSocket_1.27mm +PinSocket_2x44_P1.27mm_Horizontal +Through hole angled socket strip, 2x44, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x44 1.27mm double row +0 +88 +88 +Connector_PinSocket_1.27mm +PinSocket_2x45_P1.27mm_Horizontal +Through hole angled socket strip, 2x45, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x45 1.27mm double row +0 +90 +90 +Connector_PinSocket_1.27mm +PinSocket_2x46_P1.27mm_Horizontal +Through hole angled socket strip, 2x46, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x46 1.27mm double row +0 +92 +92 +Connector_PinSocket_1.27mm +PinSocket_2x47_P1.27mm_Horizontal +Through hole angled socket strip, 2x47, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x47 1.27mm double row +0 +94 +94 +Connector_PinSocket_1.27mm +PinSocket_2x48_P1.27mm_Horizontal +Through hole angled socket strip, 2x48, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x48 1.27mm double row +0 +96 +96 +Connector_PinSocket_1.27mm +PinSocket_2x49_P1.27mm_Horizontal +Through hole angled socket strip, 2x49, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x49 1.27mm double row +0 +98 +98 +Connector_PinSocket_1.27mm +PinSocket_2x50_P1.27mm_Horizontal +Through hole angled socket strip, 2x50, 1.27mm pitch, 4.4mm socket length, double cols (https://gct.co/pdfjs/web/viewer.html?file=/Files/Drawings/BD091.pdf&t=1511594177220), script generated +Through hole angled socket strip THT 2x50 1.27mm double row +0 +100 +100 +Connector_PinSocket_2.00mm +PinSocket_1x01_P2.00mm_Horizontal +Through hole angled socket strip, 1x01, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinSocket_2.00mm +PinSocket_1x01_P2.00mm_Vertical +Through hole straight socket strip, 1x01, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x01 2.00mm single row +0 +1 +1 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Horizontal +Through hole angled socket strip, 1x02, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Vertical +Through hole straight socket strip, 1x02, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x02 2.00mm single row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x02 2.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x02_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x02 2.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Horizontal +Through hole angled socket strip, 1x03, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Vertical +Through hole straight socket strip, 1x03, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x03 2.00mm single row +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x03 2.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x03_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x03 2.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Horizontal +Through hole angled socket strip, 1x04, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Vertical +Through hole straight socket strip, 1x04, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x04 2.00mm single row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x04 2.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x04_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x04 2.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Horizontal +Through hole angled socket strip, 1x05, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Vertical +Through hole straight socket strip, 1x05, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x05 2.00mm single row +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x05 2.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x05_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x05 2.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Horizontal +Through hole angled socket strip, 1x06, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Vertical +Through hole straight socket strip, 1x06, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x06 2.00mm single row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x06 2.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x06_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x06 2.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Horizontal +Through hole angled socket strip, 1x07, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Vertical +Through hole straight socket strip, 1x07, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x07 2.00mm single row +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x07 2.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x07_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x07 2.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Horizontal +Through hole angled socket strip, 1x08, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Vertical +Through hole straight socket strip, 1x08, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x08 2.00mm single row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x08 2.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x08_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x08 2.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Horizontal +Through hole angled socket strip, 1x09, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Vertical +Through hole straight socket strip, 1x09, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x09 2.00mm single row +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x09 2.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x09_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x09 2.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Horizontal +Through hole angled socket strip, 1x10, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Vertical +Through hole straight socket strip, 1x10, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x10 2.00mm single row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x10 2.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x10_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x10 2.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Horizontal +Through hole angled socket strip, 1x11, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Vertical +Through hole straight socket strip, 1x11, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x11 2.00mm single row +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x11 2.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x11_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x11 2.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Horizontal +Through hole angled socket strip, 1x12, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Vertical +Through hole straight socket strip, 1x12, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x12 2.00mm single row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x12 2.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x12_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x12 2.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Horizontal +Through hole angled socket strip, 1x13, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Vertical +Through hole straight socket strip, 1x13, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x13 2.00mm single row +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x13 2.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x13_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x13 2.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Horizontal +Through hole angled socket strip, 1x14, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Vertical +Through hole straight socket strip, 1x14, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x14 2.00mm single row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x14 2.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x14_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x14 2.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Horizontal +Through hole angled socket strip, 1x15, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Vertical +Through hole straight socket strip, 1x15, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x15 2.00mm single row +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x15 2.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x15_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x15 2.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Horizontal +Through hole angled socket strip, 1x16, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Vertical +Through hole straight socket strip, 1x16, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x16 2.00mm single row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x16 2.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x16_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x16 2.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Horizontal +Through hole angled socket strip, 1x17, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Vertical +Through hole straight socket strip, 1x17, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x17 2.00mm single row +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x17 2.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x17_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x17 2.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Horizontal +Through hole angled socket strip, 1x18, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Vertical +Through hole straight socket strip, 1x18, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x18 2.00mm single row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x18 2.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x18_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x18 2.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Horizontal +Through hole angled socket strip, 1x19, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Vertical +Through hole straight socket strip, 1x19, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x19 2.00mm single row +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x19 2.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x19_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x19 2.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Horizontal +Through hole angled socket strip, 1x20, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Vertical +Through hole straight socket strip, 1x20, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x20 2.00mm single row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x20 2.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x20_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x20 2.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Horizontal +Through hole angled socket strip, 1x21, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Vertical +Through hole straight socket strip, 1x21, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x21 2.00mm single row +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x21 2.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x21_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x21 2.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Horizontal +Through hole angled socket strip, 1x22, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Vertical +Through hole straight socket strip, 1x22, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x22 2.00mm single row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x22 2.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x22_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x22 2.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Horizontal +Through hole angled socket strip, 1x23, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Vertical +Through hole straight socket strip, 1x23, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x23 2.00mm single row +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x23 2.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x23_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x23 2.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Horizontal +Through hole angled socket strip, 1x24, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Vertical +Through hole straight socket strip, 1x24, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x24 2.00mm single row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x24 2.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x24_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x24 2.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Horizontal +Through hole angled socket strip, 1x25, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Vertical +Through hole straight socket strip, 1x25, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x25 2.00mm single row +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x25 2.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x25_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x25 2.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Horizontal +Through hole angled socket strip, 1x26, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Vertical +Through hole straight socket strip, 1x26, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x26 2.00mm single row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x26 2.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x26_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x26 2.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Horizontal +Through hole angled socket strip, 1x27, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Vertical +Through hole straight socket strip, 1x27, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x27 2.00mm single row +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x27 2.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x27_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x27 2.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Horizontal +Through hole angled socket strip, 1x28, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Vertical +Through hole straight socket strip, 1x28, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x28 2.00mm single row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x28 2.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x28_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x28 2.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Horizontal +Through hole angled socket strip, 1x29, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Vertical +Through hole straight socket strip, 1x29, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x29 2.00mm single row +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x29 2.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x29_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x29 2.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Horizontal +Through hole angled socket strip, 1x30, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Vertical +Through hole straight socket strip, 1x30, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x30 2.00mm single row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x30 2.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x30_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x30 2.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Horizontal +Through hole angled socket strip, 1x31, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Vertical +Through hole straight socket strip, 1x31, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x31 2.00mm single row +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x31 2.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x31_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x31 2.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Horizontal +Through hole angled socket strip, 1x32, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Vertical +Through hole straight socket strip, 1x32, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x32 2.00mm single row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x32 2.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x32_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x32 2.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Horizontal +Through hole angled socket strip, 1x33, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Vertical +Through hole straight socket strip, 1x33, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x33 2.00mm single row +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x33 2.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x33_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x33 2.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Horizontal +Through hole angled socket strip, 1x34, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Vertical +Through hole straight socket strip, 1x34, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x34 2.00mm single row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x34 2.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x34_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x34 2.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Horizontal +Through hole angled socket strip, 1x35, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Vertical +Through hole straight socket strip, 1x35, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x35 2.00mm single row +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x35 2.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x35_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x35 2.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Horizontal +Through hole angled socket strip, 1x36, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Vertical +Through hole straight socket strip, 1x36, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x36 2.00mm single row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x36 2.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x36_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x36 2.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Horizontal +Through hole angled socket strip, 1x37, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Vertical +Through hole straight socket strip, 1x37, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x37 2.00mm single row +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x37 2.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x37_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x37 2.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Horizontal +Through hole angled socket strip, 1x38, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Vertical +Through hole straight socket strip, 1x38, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x38 2.00mm single row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x38 2.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x38_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x38 2.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Horizontal +Through hole angled socket strip, 1x39, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Vertical +Through hole straight socket strip, 1x39, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x39 2.00mm single row +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x39 2.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x39_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x39 2.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Horizontal +Through hole angled socket strip, 1x40, 2.00mm pitch, 6.35mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Vertical +Through hole straight socket strip, 1x40, 2.00mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x40 2.00mm single row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 2.00mm pitch, single row, style 1 (pin 1 left) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x40 2.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_1x40_P2.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 2.00mm pitch, single row, style 2 (pin 1 right) (https://www.jayconsystems.com/fileuploader/download/download/?d=1&file=custom%2Fupload%2FFile-1375728122.pdf), script generated +Surface mounted socket strip SMD 1x40 2.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x01_P2.00mm_Horizontal +Through hole angled socket strip, 2x01, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_2x01_P2.00mm_Vertical +Through hole straight socket strip, 2x01, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x01 2.00mm double row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_2x01_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x01, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x01 2.00mm double row +0 +2 +2 +Connector_PinSocket_2.00mm +PinSocket_2x02_P2.00mm_Horizontal +Through hole angled socket strip, 2x02, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_2x02_P2.00mm_Vertical +Through hole straight socket strip, 2x02, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x02 2.00mm double row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_2x02_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x02 2.00mm double row +0 +4 +4 +Connector_PinSocket_2.00mm +PinSocket_2x03_P2.00mm_Horizontal +Through hole angled socket strip, 2x03, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_2x03_P2.00mm_Vertical +Through hole straight socket strip, 2x03, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x03 2.00mm double row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_2x03_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x03 2.00mm double row +0 +6 +6 +Connector_PinSocket_2.00mm +PinSocket_2x04_P2.00mm_Horizontal +Through hole angled socket strip, 2x04, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_2x04_P2.00mm_Vertical +Through hole straight socket strip, 2x04, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x04 2.00mm double row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_2x04_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x04 2.00mm double row +0 +8 +8 +Connector_PinSocket_2.00mm +PinSocket_2x05_P2.00mm_Horizontal +Through hole angled socket strip, 2x05, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_2x05_P2.00mm_Vertical +Through hole straight socket strip, 2x05, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x05 2.00mm double row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_2x05_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x05 2.00mm double row +0 +10 +10 +Connector_PinSocket_2.00mm +PinSocket_2x06_P2.00mm_Horizontal +Through hole angled socket strip, 2x06, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_2x06_P2.00mm_Vertical +Through hole straight socket strip, 2x06, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x06 2.00mm double row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_2x06_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x06 2.00mm double row +0 +12 +12 +Connector_PinSocket_2.00mm +PinSocket_2x07_P2.00mm_Horizontal +Through hole angled socket strip, 2x07, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_2x07_P2.00mm_Vertical +Through hole straight socket strip, 2x07, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x07 2.00mm double row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_2x07_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x07 2.00mm double row +0 +14 +14 +Connector_PinSocket_2.00mm +PinSocket_2x08_P2.00mm_Horizontal +Through hole angled socket strip, 2x08, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_2x08_P2.00mm_Vertical +Through hole straight socket strip, 2x08, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x08 2.00mm double row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_2x08_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x08 2.00mm double row +0 +16 +16 +Connector_PinSocket_2.00mm +PinSocket_2x09_P2.00mm_Horizontal +Through hole angled socket strip, 2x09, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_2x09_P2.00mm_Vertical +Through hole straight socket strip, 2x09, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x09 2.00mm double row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_2x09_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x09 2.00mm double row +0 +18 +18 +Connector_PinSocket_2.00mm +PinSocket_2x10_P2.00mm_Horizontal +Through hole angled socket strip, 2x10, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_2x10_P2.00mm_Vertical +Through hole straight socket strip, 2x10, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x10 2.00mm double row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_2x10_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x10 2.00mm double row +0 +20 +20 +Connector_PinSocket_2.00mm +PinSocket_2x11_P2.00mm_Horizontal +Through hole angled socket strip, 2x11, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_2x11_P2.00mm_Vertical +Through hole straight socket strip, 2x11, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x11 2.00mm double row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_2x11_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x11 2.00mm double row +0 +22 +22 +Connector_PinSocket_2.00mm +PinSocket_2x12_P2.00mm_Horizontal +Through hole angled socket strip, 2x12, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_2x12_P2.00mm_Vertical +Through hole straight socket strip, 2x12, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x12 2.00mm double row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_2x12_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x12 2.00mm double row +0 +24 +24 +Connector_PinSocket_2.00mm +PinSocket_2x13_P2.00mm_Horizontal +Through hole angled socket strip, 2x13, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_2x13_P2.00mm_Vertical +Through hole straight socket strip, 2x13, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x13 2.00mm double row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_2x13_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x13 2.00mm double row +0 +26 +26 +Connector_PinSocket_2.00mm +PinSocket_2x14_P2.00mm_Horizontal +Through hole angled socket strip, 2x14, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_2x14_P2.00mm_Vertical +Through hole straight socket strip, 2x14, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x14 2.00mm double row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_2x14_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x14 2.00mm double row +0 +28 +28 +Connector_PinSocket_2.00mm +PinSocket_2x15_P2.00mm_Horizontal +Through hole angled socket strip, 2x15, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_2x15_P2.00mm_Vertical +Through hole straight socket strip, 2x15, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x15 2.00mm double row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_2x15_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x15 2.00mm double row +0 +30 +30 +Connector_PinSocket_2.00mm +PinSocket_2x16_P2.00mm_Horizontal +Through hole angled socket strip, 2x16, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_2x16_P2.00mm_Vertical +Through hole straight socket strip, 2x16, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x16 2.00mm double row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_2x16_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x16 2.00mm double row +0 +32 +32 +Connector_PinSocket_2.00mm +PinSocket_2x17_P2.00mm_Horizontal +Through hole angled socket strip, 2x17, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_2x17_P2.00mm_Vertical +Through hole straight socket strip, 2x17, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x17 2.00mm double row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_2x17_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x17 2.00mm double row +0 +34 +34 +Connector_PinSocket_2.00mm +PinSocket_2x18_P2.00mm_Horizontal +Through hole angled socket strip, 2x18, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_2x18_P2.00mm_Vertical +Through hole straight socket strip, 2x18, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x18 2.00mm double row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_2x18_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x18 2.00mm double row +0 +36 +36 +Connector_PinSocket_2.00mm +PinSocket_2x19_P2.00mm_Horizontal +Through hole angled socket strip, 2x19, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_2x19_P2.00mm_Vertical +Through hole straight socket strip, 2x19, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x19 2.00mm double row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_2x19_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x19 2.00mm double row +0 +38 +38 +Connector_PinSocket_2.00mm +PinSocket_2x20_P2.00mm_Horizontal +Through hole angled socket strip, 2x20, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x20_P2.00mm_Vertical +Through hole straight socket strip, 2x20, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x20 2.00mm double row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x20_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x20 2.00mm double row +0 +40 +40 +Connector_PinSocket_2.00mm +PinSocket_2x21_P2.00mm_Horizontal +Through hole angled socket strip, 2x21, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinSocket_2.00mm +PinSocket_2x21_P2.00mm_Vertical +Through hole straight socket strip, 2x21, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x21 2.00mm double row +0 +42 +42 +Connector_PinSocket_2.00mm +PinSocket_2x21_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x21 2.00mm double row +0 +42 +42 +Connector_PinSocket_2.00mm +PinSocket_2x22_P2.00mm_Horizontal +Through hole angled socket strip, 2x22, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinSocket_2.00mm +PinSocket_2x22_P2.00mm_Vertical +Through hole straight socket strip, 2x22, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x22 2.00mm double row +0 +44 +44 +Connector_PinSocket_2.00mm +PinSocket_2x22_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x22 2.00mm double row +0 +44 +44 +Connector_PinSocket_2.00mm +PinSocket_2x23_P2.00mm_Horizontal +Through hole angled socket strip, 2x23, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinSocket_2.00mm +PinSocket_2x23_P2.00mm_Vertical +Through hole straight socket strip, 2x23, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x23 2.00mm double row +0 +46 +46 +Connector_PinSocket_2.00mm +PinSocket_2x23_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x23 2.00mm double row +0 +46 +46 +Connector_PinSocket_2.00mm +PinSocket_2x24_P2.00mm_Horizontal +Through hole angled socket strip, 2x24, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinSocket_2.00mm +PinSocket_2x24_P2.00mm_Vertical +Through hole straight socket strip, 2x24, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x24 2.00mm double row +0 +48 +48 +Connector_PinSocket_2.00mm +PinSocket_2x24_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x24 2.00mm double row +0 +48 +48 +Connector_PinSocket_2.00mm +PinSocket_2x25_P2.00mm_Horizontal +Through hole angled socket strip, 2x25, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinSocket_2.00mm +PinSocket_2x25_P2.00mm_Vertical +Through hole straight socket strip, 2x25, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x25 2.00mm double row +0 +50 +50 +Connector_PinSocket_2.00mm +PinSocket_2x25_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x25 2.00mm double row +0 +50 +50 +Connector_PinSocket_2.00mm +PinSocket_2x26_P2.00mm_Horizontal +Through hole angled socket strip, 2x26, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinSocket_2.00mm +PinSocket_2x26_P2.00mm_Vertical +Through hole straight socket strip, 2x26, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x26 2.00mm double row +0 +52 +52 +Connector_PinSocket_2.00mm +PinSocket_2x26_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x26 2.00mm double row +0 +52 +52 +Connector_PinSocket_2.00mm +PinSocket_2x27_P2.00mm_Horizontal +Through hole angled socket strip, 2x27, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinSocket_2.00mm +PinSocket_2x27_P2.00mm_Vertical +Through hole straight socket strip, 2x27, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x27 2.00mm double row +0 +54 +54 +Connector_PinSocket_2.00mm +PinSocket_2x27_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x27 2.00mm double row +0 +54 +54 +Connector_PinSocket_2.00mm +PinSocket_2x28_P2.00mm_Horizontal +Through hole angled socket strip, 2x28, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinSocket_2.00mm +PinSocket_2x28_P2.00mm_Vertical +Through hole straight socket strip, 2x28, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x28 2.00mm double row +0 +56 +56 +Connector_PinSocket_2.00mm +PinSocket_2x28_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x28 2.00mm double row +0 +56 +56 +Connector_PinSocket_2.00mm +PinSocket_2x29_P2.00mm_Horizontal +Through hole angled socket strip, 2x29, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinSocket_2.00mm +PinSocket_2x29_P2.00mm_Vertical +Through hole straight socket strip, 2x29, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x29 2.00mm double row +0 +58 +58 +Connector_PinSocket_2.00mm +PinSocket_2x29_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x29 2.00mm double row +0 +58 +58 +Connector_PinSocket_2.00mm +PinSocket_2x30_P2.00mm_Horizontal +Through hole angled socket strip, 2x30, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinSocket_2.00mm +PinSocket_2x30_P2.00mm_Vertical +Through hole straight socket strip, 2x30, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x30 2.00mm double row +0 +60 +60 +Connector_PinSocket_2.00mm +PinSocket_2x30_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x30 2.00mm double row +0 +60 +60 +Connector_PinSocket_2.00mm +PinSocket_2x31_P2.00mm_Horizontal +Through hole angled socket strip, 2x31, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinSocket_2.00mm +PinSocket_2x31_P2.00mm_Vertical +Through hole straight socket strip, 2x31, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x31 2.00mm double row +0 +62 +62 +Connector_PinSocket_2.00mm +PinSocket_2x31_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x31 2.00mm double row +0 +62 +62 +Connector_PinSocket_2.00mm +PinSocket_2x32_P2.00mm_Horizontal +Through hole angled socket strip, 2x32, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinSocket_2.00mm +PinSocket_2x32_P2.00mm_Vertical +Through hole straight socket strip, 2x32, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x32 2.00mm double row +0 +64 +64 +Connector_PinSocket_2.00mm +PinSocket_2x32_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x32 2.00mm double row +0 +64 +64 +Connector_PinSocket_2.00mm +PinSocket_2x33_P2.00mm_Horizontal +Through hole angled socket strip, 2x33, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinSocket_2.00mm +PinSocket_2x33_P2.00mm_Vertical +Through hole straight socket strip, 2x33, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x33 2.00mm double row +0 +66 +66 +Connector_PinSocket_2.00mm +PinSocket_2x33_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x33 2.00mm double row +0 +66 +66 +Connector_PinSocket_2.00mm +PinSocket_2x34_P2.00mm_Horizontal +Through hole angled socket strip, 2x34, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinSocket_2.00mm +PinSocket_2x34_P2.00mm_Vertical +Through hole straight socket strip, 2x34, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x34 2.00mm double row +0 +68 +68 +Connector_PinSocket_2.00mm +PinSocket_2x34_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x34 2.00mm double row +0 +68 +68 +Connector_PinSocket_2.00mm +PinSocket_2x35_P2.00mm_Horizontal +Through hole angled socket strip, 2x35, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinSocket_2.00mm +PinSocket_2x35_P2.00mm_Vertical +Through hole straight socket strip, 2x35, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x35 2.00mm double row +0 +70 +70 +Connector_PinSocket_2.00mm +PinSocket_2x35_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x35 2.00mm double row +0 +70 +70 +Connector_PinSocket_2.00mm +PinSocket_2x36_P2.00mm_Horizontal +Through hole angled socket strip, 2x36, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinSocket_2.00mm +PinSocket_2x36_P2.00mm_Vertical +Through hole straight socket strip, 2x36, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x36 2.00mm double row +0 +72 +72 +Connector_PinSocket_2.00mm +PinSocket_2x36_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x36 2.00mm double row +0 +72 +72 +Connector_PinSocket_2.00mm +PinSocket_2x37_P2.00mm_Horizontal +Through hole angled socket strip, 2x37, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinSocket_2.00mm +PinSocket_2x37_P2.00mm_Vertical +Through hole straight socket strip, 2x37, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x37 2.00mm double row +0 +74 +74 +Connector_PinSocket_2.00mm +PinSocket_2x37_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x37 2.00mm double row +0 +74 +74 +Connector_PinSocket_2.00mm +PinSocket_2x38_P2.00mm_Horizontal +Through hole angled socket strip, 2x38, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinSocket_2.00mm +PinSocket_2x38_P2.00mm_Vertical +Through hole straight socket strip, 2x38, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x38 2.00mm double row +0 +76 +76 +Connector_PinSocket_2.00mm +PinSocket_2x38_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x38 2.00mm double row +0 +76 +76 +Connector_PinSocket_2.00mm +PinSocket_2x39_P2.00mm_Horizontal +Through hole angled socket strip, 2x39, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinSocket_2.00mm +PinSocket_2x39_P2.00mm_Vertical +Through hole straight socket strip, 2x39, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x39 2.00mm double row +0 +78 +78 +Connector_PinSocket_2.00mm +PinSocket_2x39_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x39 2.00mm double row +0 +78 +78 +Connector_PinSocket_2.00mm +PinSocket_2x40_P2.00mm_Horizontal +Through hole angled socket strip, 2x40, 2.00mm pitch, 6.35mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinSocket_2.00mm +PinSocket_2x40_P2.00mm_Vertical +Through hole straight socket strip, 2x40, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x40 2.00mm double row +0 +80 +80 +Connector_PinSocket_2.00mm +PinSocket_2x40_P2.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 2.00mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x40 2.00mm double row +0 +80 +80 +Connector_PinSocket_2.54mm +PinSocket_1x01_P2.54mm_Horizontal +Through hole angled socket strip, 1x01, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinSocket_2.54mm +PinSocket_1x01_P2.54mm_Vertical +Through hole straight socket strip, 1x01, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x01 2.54mm single row +0 +1 +1 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Horizontal +Through hole angled socket strip, 1x02, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Vertical +Through hole straight socket strip, 1x02, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x02 2.54mm single row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x02 2.54mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x02_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x02 2.54mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Horizontal +Through hole angled socket strip, 1x03, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Vertical +Through hole straight socket strip, 1x03, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x03 2.54mm single row +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x03 2.54mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x03_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x03 2.54mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Horizontal +Through hole angled socket strip, 1x04, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Vertical +Through hole straight socket strip, 1x04, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x04 2.54mm single row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x04 2.54mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x04_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x04 2.54mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Horizontal +Through hole angled socket strip, 1x05, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Vertical +Through hole straight socket strip, 1x05, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x05 2.54mm single row +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x05 2.54mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x05_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x05 2.54mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Horizontal +Through hole angled socket strip, 1x06, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Vertical +Through hole straight socket strip, 1x06, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x06 2.54mm single row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x06 2.54mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x06_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x06 2.54mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Horizontal +Through hole angled socket strip, 1x07, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Vertical +Through hole straight socket strip, 1x07, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x07 2.54mm single row +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x07 2.54mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x07_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x07 2.54mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Horizontal +Through hole angled socket strip, 1x08, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Vertical +Through hole straight socket strip, 1x08, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x08 2.54mm single row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x08 2.54mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x08_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x08 2.54mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Horizontal +Through hole angled socket strip, 1x09, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Vertical +Through hole straight socket strip, 1x09, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x09 2.54mm single row +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x09 2.54mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x09_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x09 2.54mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Horizontal +Through hole angled socket strip, 1x10, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Vertical +Through hole straight socket strip, 1x10, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x10 2.54mm single row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x10 2.54mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x10_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x10 2.54mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Horizontal +Through hole angled socket strip, 1x11, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Vertical +Through hole straight socket strip, 1x11, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x11 2.54mm single row +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x11 2.54mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x11_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x11 2.54mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Horizontal +Through hole angled socket strip, 1x12, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Vertical +Through hole straight socket strip, 1x12, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x12 2.54mm single row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x12 2.54mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x12_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x12 2.54mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Horizontal +Through hole angled socket strip, 1x13, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Vertical +Through hole straight socket strip, 1x13, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x13 2.54mm single row +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x13 2.54mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x13_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x13 2.54mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Horizontal +Through hole angled socket strip, 1x14, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Vertical +Through hole straight socket strip, 1x14, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x14 2.54mm single row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x14 2.54mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x14_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x14 2.54mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Horizontal +Through hole angled socket strip, 1x15, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Vertical +Through hole straight socket strip, 1x15, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x15 2.54mm single row +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x15 2.54mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x15_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x15 2.54mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Horizontal +Through hole angled socket strip, 1x16, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Vertical +Through hole straight socket strip, 1x16, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x16 2.54mm single row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x16 2.54mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x16_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x16 2.54mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Horizontal +Through hole angled socket strip, 1x17, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Vertical +Through hole straight socket strip, 1x17, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x17 2.54mm single row +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x17 2.54mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x17_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x17 2.54mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Horizontal +Through hole angled socket strip, 1x18, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Vertical +Through hole straight socket strip, 1x18, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x18 2.54mm single row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x18 2.54mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x18_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x18 2.54mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Horizontal +Through hole angled socket strip, 1x19, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Vertical +Through hole straight socket strip, 1x19, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x19 2.54mm single row +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x19 2.54mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x19_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x19 2.54mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Horizontal +Through hole angled socket strip, 1x20, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Vertical +Through hole straight socket strip, 1x20, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x20 2.54mm single row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x20 2.54mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x20_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x20 2.54mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Horizontal +Through hole angled socket strip, 1x21, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Vertical +Through hole straight socket strip, 1x21, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x21 2.54mm single row +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x21 2.54mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x21_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x21 2.54mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Horizontal +Through hole angled socket strip, 1x22, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Vertical +Through hole straight socket strip, 1x22, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x22 2.54mm single row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x22 2.54mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x22_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x22 2.54mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Horizontal +Through hole angled socket strip, 1x23, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Vertical +Through hole straight socket strip, 1x23, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x23 2.54mm single row +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x23 2.54mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x23_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x23 2.54mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Horizontal +Through hole angled socket strip, 1x24, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Vertical +Through hole straight socket strip, 1x24, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x24 2.54mm single row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x24 2.54mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x24_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x24 2.54mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Horizontal +Through hole angled socket strip, 1x25, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Vertical +Through hole straight socket strip, 1x25, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x25 2.54mm single row +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x25 2.54mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x25_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x25 2.54mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Horizontal +Through hole angled socket strip, 1x26, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Vertical +Through hole straight socket strip, 1x26, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x26 2.54mm single row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x26 2.54mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x26_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x26 2.54mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Horizontal +Through hole angled socket strip, 1x27, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Vertical +Through hole straight socket strip, 1x27, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x27 2.54mm single row +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x27 2.54mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x27_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x27 2.54mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Horizontal +Through hole angled socket strip, 1x28, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Vertical +Through hole straight socket strip, 1x28, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x28 2.54mm single row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x28 2.54mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x28_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x28 2.54mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Horizontal +Through hole angled socket strip, 1x29, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Vertical +Through hole straight socket strip, 1x29, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x29 2.54mm single row +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x29 2.54mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x29_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x29 2.54mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Horizontal +Through hole angled socket strip, 1x30, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Vertical +Through hole straight socket strip, 1x30, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x30 2.54mm single row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x30 2.54mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x30_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x30 2.54mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Horizontal +Through hole angled socket strip, 1x31, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Vertical +Through hole straight socket strip, 1x31, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x31 2.54mm single row +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x31 2.54mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x31_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x31 2.54mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Horizontal +Through hole angled socket strip, 1x32, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Vertical +Through hole straight socket strip, 1x32, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x32 2.54mm single row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x32 2.54mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x32_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x32 2.54mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Horizontal +Through hole angled socket strip, 1x33, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Vertical +Through hole straight socket strip, 1x33, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x33 2.54mm single row +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x33 2.54mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x33_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x33 2.54mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Horizontal +Through hole angled socket strip, 1x34, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Vertical +Through hole straight socket strip, 1x34, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x34 2.54mm single row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x34 2.54mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x34_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x34 2.54mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Horizontal +Through hole angled socket strip, 1x35, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Vertical +Through hole straight socket strip, 1x35, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x35 2.54mm single row +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x35 2.54mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x35_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x35 2.54mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Horizontal +Through hole angled socket strip, 1x36, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Vertical +Through hole straight socket strip, 1x36, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x36 2.54mm single row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x36 2.54mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x36_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x36 2.54mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Horizontal +Through hole angled socket strip, 1x37, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Vertical +Through hole straight socket strip, 1x37, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x37 2.54mm single row +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x37 2.54mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x37_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x37 2.54mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Horizontal +Through hole angled socket strip, 1x38, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Vertical +Through hole straight socket strip, 1x38, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x38 2.54mm single row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x38 2.54mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x38_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x38 2.54mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Horizontal +Through hole angled socket strip, 1x39, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Vertical +Through hole straight socket strip, 1x39, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x39 2.54mm single row +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x39 2.54mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x39_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x39 2.54mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Horizontal +Through hole angled socket strip, 1x40, 2.54mm pitch, 8.51mm socket length, single row (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Vertical +Through hole straight socket strip, 1x40, 2.54mm pitch, single row (from Kicad 4.0.7), script generated +Through hole socket strip THT 1x40 2.54mm single row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 2.54mm pitch, single row, style 1 (pin 1 left) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x40 2.54mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_1x40_P2.54mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 2.54mm pitch, single row, style 2 (pin 1 right) (https://cdn.harwin.com/pdfs/M20-786.pdf), script generated +Surface mounted socket strip SMD 1x40 2.54mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x01_P2.54mm_Horizontal +Through hole angled socket strip, 2x01, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_2x01_P2.54mm_Vertical +Through hole straight socket strip, 2x01, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x01 2.54mm double row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_2x01_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x01, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x01 2.54mm double row +0 +2 +2 +Connector_PinSocket_2.54mm +PinSocket_2x02_P2.54mm_Horizontal +Through hole angled socket strip, 2x02, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_2x02_P2.54mm_Vertical +Through hole straight socket strip, 2x02, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x02 2.54mm double row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_2x02_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x02 2.54mm double row +0 +4 +4 +Connector_PinSocket_2.54mm +PinSocket_2x03_P2.54mm_Horizontal +Through hole angled socket strip, 2x03, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_2x03_P2.54mm_Vertical +Through hole straight socket strip, 2x03, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x03 2.54mm double row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_2x03_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x03 2.54mm double row +0 +6 +6 +Connector_PinSocket_2.54mm +PinSocket_2x04_P2.54mm_Horizontal +Through hole angled socket strip, 2x04, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_2x04_P2.54mm_Vertical +Through hole straight socket strip, 2x04, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x04 2.54mm double row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_2x04_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x04 2.54mm double row +0 +8 +8 +Connector_PinSocket_2.54mm +PinSocket_2x05_P2.54mm_Horizontal +Through hole angled socket strip, 2x05, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_2x05_P2.54mm_Vertical +Through hole straight socket strip, 2x05, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x05 2.54mm double row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_2x05_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x05 2.54mm double row +0 +10 +10 +Connector_PinSocket_2.54mm +PinSocket_2x06_P2.54mm_Horizontal +Through hole angled socket strip, 2x06, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_2x06_P2.54mm_Vertical +Through hole straight socket strip, 2x06, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x06 2.54mm double row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_2x06_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x06 2.54mm double row +0 +12 +12 +Connector_PinSocket_2.54mm +PinSocket_2x07_P2.54mm_Horizontal +Through hole angled socket strip, 2x07, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_2x07_P2.54mm_Vertical +Through hole straight socket strip, 2x07, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x07 2.54mm double row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_2x07_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x07 2.54mm double row +0 +14 +14 +Connector_PinSocket_2.54mm +PinSocket_2x08_P2.54mm_Horizontal +Through hole angled socket strip, 2x08, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_2x08_P2.54mm_Vertical +Through hole straight socket strip, 2x08, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x08 2.54mm double row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_2x08_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x08 2.54mm double row +0 +16 +16 +Connector_PinSocket_2.54mm +PinSocket_2x09_P2.54mm_Horizontal +Through hole angled socket strip, 2x09, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_2x09_P2.54mm_Vertical +Through hole straight socket strip, 2x09, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x09 2.54mm double row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_2x09_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x09 2.54mm double row +0 +18 +18 +Connector_PinSocket_2.54mm +PinSocket_2x10_P2.54mm_Horizontal +Through hole angled socket strip, 2x10, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_2x10_P2.54mm_Vertical +Through hole straight socket strip, 2x10, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x10 2.54mm double row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_2x10_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x10 2.54mm double row +0 +20 +20 +Connector_PinSocket_2.54mm +PinSocket_2x11_P2.54mm_Horizontal +Through hole angled socket strip, 2x11, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_2x11_P2.54mm_Vertical +Through hole straight socket strip, 2x11, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x11 2.54mm double row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_2x11_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x11 2.54mm double row +0 +22 +22 +Connector_PinSocket_2.54mm +PinSocket_2x12_P2.54mm_Horizontal +Through hole angled socket strip, 2x12, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_2x12_P2.54mm_Vertical +Through hole straight socket strip, 2x12, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x12 2.54mm double row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_2x12_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x12 2.54mm double row +0 +24 +24 +Connector_PinSocket_2.54mm +PinSocket_2x13_P2.54mm_Horizontal +Through hole angled socket strip, 2x13, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_2x13_P2.54mm_Vertical +Through hole straight socket strip, 2x13, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x13 2.54mm double row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_2x13_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x13 2.54mm double row +0 +26 +26 +Connector_PinSocket_2.54mm +PinSocket_2x14_P2.54mm_Horizontal +Through hole angled socket strip, 2x14, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_2x14_P2.54mm_Vertical +Through hole straight socket strip, 2x14, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x14 2.54mm double row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_2x14_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x14 2.54mm double row +0 +28 +28 +Connector_PinSocket_2.54mm +PinSocket_2x15_P2.54mm_Horizontal +Through hole angled socket strip, 2x15, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_2x15_P2.54mm_Vertical +Through hole straight socket strip, 2x15, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x15 2.54mm double row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_2x15_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x15 2.54mm double row +0 +30 +30 +Connector_PinSocket_2.54mm +PinSocket_2x16_P2.54mm_Horizontal +Through hole angled socket strip, 2x16, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_2x16_P2.54mm_Vertical +Through hole straight socket strip, 2x16, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x16 2.54mm double row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_2x16_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x16 2.54mm double row +0 +32 +32 +Connector_PinSocket_2.54mm +PinSocket_2x17_P2.54mm_Horizontal +Through hole angled socket strip, 2x17, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_2x17_P2.54mm_Vertical +Through hole straight socket strip, 2x17, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x17 2.54mm double row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_2x17_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x17 2.54mm double row +0 +34 +34 +Connector_PinSocket_2.54mm +PinSocket_2x18_P2.54mm_Horizontal +Through hole angled socket strip, 2x18, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_2x18_P2.54mm_Vertical +Through hole straight socket strip, 2x18, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x18 2.54mm double row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_2x18_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x18 2.54mm double row +0 +36 +36 +Connector_PinSocket_2.54mm +PinSocket_2x19_P2.54mm_Horizontal +Through hole angled socket strip, 2x19, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_2x19_P2.54mm_Vertical +Through hole straight socket strip, 2x19, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x19 2.54mm double row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_2x19_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x19 2.54mm double row +0 +38 +38 +Connector_PinSocket_2.54mm +PinSocket_2x20_P2.54mm_Horizontal +Through hole angled socket strip, 2x20, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x20_P2.54mm_Vertical +Through hole straight socket strip, 2x20, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x20 2.54mm double row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x20_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x20 2.54mm double row +0 +40 +40 +Connector_PinSocket_2.54mm +PinSocket_2x21_P2.54mm_Horizontal +Through hole angled socket strip, 2x21, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinSocket_2.54mm +PinSocket_2x21_P2.54mm_Vertical +Through hole straight socket strip, 2x21, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x21 2.54mm double row +0 +42 +42 +Connector_PinSocket_2.54mm +PinSocket_2x21_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x21 2.54mm double row +0 +42 +42 +Connector_PinSocket_2.54mm +PinSocket_2x22_P2.54mm_Horizontal +Through hole angled socket strip, 2x22, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinSocket_2.54mm +PinSocket_2x22_P2.54mm_Vertical +Through hole straight socket strip, 2x22, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x22 2.54mm double row +0 +44 +44 +Connector_PinSocket_2.54mm +PinSocket_2x22_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x22 2.54mm double row +0 +44 +44 +Connector_PinSocket_2.54mm +PinSocket_2x23_P2.54mm_Horizontal +Through hole angled socket strip, 2x23, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinSocket_2.54mm +PinSocket_2x23_P2.54mm_Vertical +Through hole straight socket strip, 2x23, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x23 2.54mm double row +0 +46 +46 +Connector_PinSocket_2.54mm +PinSocket_2x23_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x23 2.54mm double row +0 +46 +46 +Connector_PinSocket_2.54mm +PinSocket_2x24_P2.54mm_Horizontal +Through hole angled socket strip, 2x24, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinSocket_2.54mm +PinSocket_2x24_P2.54mm_Vertical +Through hole straight socket strip, 2x24, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x24 2.54mm double row +0 +48 +48 +Connector_PinSocket_2.54mm +PinSocket_2x24_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x24 2.54mm double row +0 +48 +48 +Connector_PinSocket_2.54mm +PinSocket_2x25_P2.54mm_Horizontal +Through hole angled socket strip, 2x25, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinSocket_2.54mm +PinSocket_2x25_P2.54mm_Vertical +Through hole straight socket strip, 2x25, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x25 2.54mm double row +0 +50 +50 +Connector_PinSocket_2.54mm +PinSocket_2x25_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x25 2.54mm double row +0 +50 +50 +Connector_PinSocket_2.54mm +PinSocket_2x26_P2.54mm_Horizontal +Through hole angled socket strip, 2x26, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinSocket_2.54mm +PinSocket_2x26_P2.54mm_Vertical +Through hole straight socket strip, 2x26, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x26 2.54mm double row +0 +52 +52 +Connector_PinSocket_2.54mm +PinSocket_2x26_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x26 2.54mm double row +0 +52 +52 +Connector_PinSocket_2.54mm +PinSocket_2x27_P2.54mm_Horizontal +Through hole angled socket strip, 2x27, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinSocket_2.54mm +PinSocket_2x27_P2.54mm_Vertical +Through hole straight socket strip, 2x27, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x27 2.54mm double row +0 +54 +54 +Connector_PinSocket_2.54mm +PinSocket_2x27_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x27 2.54mm double row +0 +54 +54 +Connector_PinSocket_2.54mm +PinSocket_2x28_P2.54mm_Horizontal +Through hole angled socket strip, 2x28, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinSocket_2.54mm +PinSocket_2x28_P2.54mm_Vertical +Through hole straight socket strip, 2x28, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x28 2.54mm double row +0 +56 +56 +Connector_PinSocket_2.54mm +PinSocket_2x28_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x28 2.54mm double row +0 +56 +56 +Connector_PinSocket_2.54mm +PinSocket_2x29_P2.54mm_Horizontal +Through hole angled socket strip, 2x29, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinSocket_2.54mm +PinSocket_2x29_P2.54mm_Vertical +Through hole straight socket strip, 2x29, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x29 2.54mm double row +0 +58 +58 +Connector_PinSocket_2.54mm +PinSocket_2x29_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x29 2.54mm double row +0 +58 +58 +Connector_PinSocket_2.54mm +PinSocket_2x30_P2.54mm_Horizontal +Through hole angled socket strip, 2x30, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinSocket_2.54mm +PinSocket_2x30_P2.54mm_Vertical +Through hole straight socket strip, 2x30, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x30 2.54mm double row +0 +60 +60 +Connector_PinSocket_2.54mm +PinSocket_2x30_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x30 2.54mm double row +0 +60 +60 +Connector_PinSocket_2.54mm +PinSocket_2x31_P2.54mm_Horizontal +Through hole angled socket strip, 2x31, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinSocket_2.54mm +PinSocket_2x31_P2.54mm_Vertical +Through hole straight socket strip, 2x31, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x31 2.54mm double row +0 +62 +62 +Connector_PinSocket_2.54mm +PinSocket_2x31_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x31 2.54mm double row +0 +62 +62 +Connector_PinSocket_2.54mm +PinSocket_2x32_P2.54mm_Horizontal +Through hole angled socket strip, 2x32, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinSocket_2.54mm +PinSocket_2x32_P2.54mm_Vertical +Through hole straight socket strip, 2x32, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x32 2.54mm double row +0 +64 +64 +Connector_PinSocket_2.54mm +PinSocket_2x32_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x32 2.54mm double row +0 +64 +64 +Connector_PinSocket_2.54mm +PinSocket_2x33_P2.54mm_Horizontal +Through hole angled socket strip, 2x33, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinSocket_2.54mm +PinSocket_2x33_P2.54mm_Vertical +Through hole straight socket strip, 2x33, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x33 2.54mm double row +0 +66 +66 +Connector_PinSocket_2.54mm +PinSocket_2x33_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x33 2.54mm double row +0 +66 +66 +Connector_PinSocket_2.54mm +PinSocket_2x34_P2.54mm_Horizontal +Through hole angled socket strip, 2x34, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinSocket_2.54mm +PinSocket_2x34_P2.54mm_Vertical +Through hole straight socket strip, 2x34, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x34 2.54mm double row +0 +68 +68 +Connector_PinSocket_2.54mm +PinSocket_2x34_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x34 2.54mm double row +0 +68 +68 +Connector_PinSocket_2.54mm +PinSocket_2x35_P2.54mm_Horizontal +Through hole angled socket strip, 2x35, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinSocket_2.54mm +PinSocket_2x35_P2.54mm_Vertical +Through hole straight socket strip, 2x35, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x35 2.54mm double row +0 +70 +70 +Connector_PinSocket_2.54mm +PinSocket_2x35_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x35 2.54mm double row +0 +70 +70 +Connector_PinSocket_2.54mm +PinSocket_2x36_P2.54mm_Horizontal +Through hole angled socket strip, 2x36, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinSocket_2.54mm +PinSocket_2x36_P2.54mm_Vertical +Through hole straight socket strip, 2x36, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x36 2.54mm double row +0 +72 +72 +Connector_PinSocket_2.54mm +PinSocket_2x36_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x36 2.54mm double row +0 +72 +72 +Connector_PinSocket_2.54mm +PinSocket_2x37_P2.54mm_Horizontal +Through hole angled socket strip, 2x37, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinSocket_2.54mm +PinSocket_2x37_P2.54mm_Vertical +Through hole straight socket strip, 2x37, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x37 2.54mm double row +0 +74 +74 +Connector_PinSocket_2.54mm +PinSocket_2x37_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x37 2.54mm double row +0 +74 +74 +Connector_PinSocket_2.54mm +PinSocket_2x38_P2.54mm_Horizontal +Through hole angled socket strip, 2x38, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinSocket_2.54mm +PinSocket_2x38_P2.54mm_Vertical +Through hole straight socket strip, 2x38, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x38 2.54mm double row +0 +76 +76 +Connector_PinSocket_2.54mm +PinSocket_2x38_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x38 2.54mm double row +0 +76 +76 +Connector_PinSocket_2.54mm +PinSocket_2x39_P2.54mm_Horizontal +Through hole angled socket strip, 2x39, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinSocket_2.54mm +PinSocket_2x39_P2.54mm_Vertical +Through hole straight socket strip, 2x39, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x39 2.54mm double row +0 +78 +78 +Connector_PinSocket_2.54mm +PinSocket_2x39_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x39 2.54mm double row +0 +78 +78 +Connector_PinSocket_2.54mm +PinSocket_2x40_P2.54mm_Horizontal +Through hole angled socket strip, 2x40, 2.54mm pitch, 8.51mm socket length, double cols (from Kicad 4.0.7), script generated +Through hole angled socket strip THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinSocket_2.54mm +PinSocket_2x40_P2.54mm_Vertical +Through hole straight socket strip, 2x40, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Through hole socket strip THT 2x40 2.54mm double row +0 +80 +80 +Connector_PinSocket_2.54mm +PinSocket_2x40_P2.54mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 2.54mm pitch, double cols (from Kicad 4.0.7), script generated +Surface mounted socket strip SMD 2x40 2.54mm double row +0 +80 +80 +Connector_RJ +RJ12_Amphenol_54601 +RJ12 connector https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/c-bmj-0082.pdf +RJ12 connector +0 +6 +6 +Connector_RJ +RJ14_Connfly_DS1133-S4_Horizontal +RJ14 connector 6P4C Horizontal http://www.connfly.com/userfiles/image/UpLoadFile/File/2012/10/26/DS1133.pdf +RJ14 connector 6P4C Connfly DS1133 +0 +4 +4 +Connector_RJ +RJ25_Wayconn_MJEA-660X1_Horizontal +RJ25 6P6C Socket 90 degrees, https://wayconn.com/wp-content/themes/way/datasheet/MJEA-660X1XXX_RJ25_6P6C_PCB_RA.pdf +RJ12 RJ18 RJ25 jack connector 6P6C +0 +6 +6 +Connector_RJ +RJ45_Abracon_ARJP11A-MA_Horizontal +Shielded RJ45 ethernet connector with transformer and POE (https://abracon.com/Magnetics/lan/ARJP11A.PDF) +ethernet 8p8c transformer poe rj45 +0 +15 +14 +Connector_RJ +RJ45_Amphenol_54602-x08_Horizontal +8 Pol Shallow Latch Connector, Modjack, RJ45 (https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/c-bmj-0102.pdf) +RJ45 +0 +8 +8 +Connector_RJ +RJ45_Amphenol_RJHSE538X +Shielded, 2 LED, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X.pdf +RJ45 8p8c ethernet cat5 +0 +14 +13 +Connector_RJ +RJ45_Amphenol_RJHSE538X-02 +Shielded, 2 LED, 2 Ports, http://www.amphenolinfocom.eu/NavData/Drawings/RJHSE-538X-02-REVC.pdf +RJ45 8p8c dual ethernet cat5 +0 +26 +25 +Connector_RJ +RJ45_Amphenol_RJHSE5380 +Shielded, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X.pdf +RJ45 8p8c ethernet cat5 +0 +10 +9 +Connector_RJ +RJ45_Amphenol_RJHSE5380-08 +Shielded, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X08.pdf +RJ45 8p8c ethernet cat5 +0 +68 +65 +Connector_RJ +RJ45_Amphenol_RJMG1BD3B8K1ANR +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, AutoMDIX, https://www.amphenolcanada.com/ProductSearch/Drawings/AC/RJMG1BD3B8K1ANR.PDF +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_BEL_SS74301-00x_Vertical +https://belfuse.com/resources/drawings/stewartconnector/dr-stw-ss-74301-001-ss-74301-002-ss-74301-005.pdf +RJ45 Vertical Shield LED Green Yellow +0 +14 +13 +Connector_RJ +RJ45_Cetus_J1B1211CCD_Horizontal +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, Cetus, used and distributed by WIZnet (https://wizwiki.net/wiki/lib/exe/fetch.php?media=products:wiz550web:wiz550webds_kr:j1b1211ccd.pdf) +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Hanrun_HR911105A +http://www.kosmodrom.com.ua/pdf/HR911105A.pdf +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Molex_0855135013_Vertical +1 Port, RJ45, Series 85513, vertical, SMD, https://www.molex.com/pdm_docs/sd/855135013_sd.pdf +RJ45 Vertical +0 +9 +9 +Connector_RJ +RJ45_Ninigi_GE +1 port ethernet throughhole connector, https://en.ninigi.com/product/rj45ge/pdf +RJ45 ethernet 8p8c +0 +10 +9 +Connector_RJ +RJ45_OST_PJ012-8P8CX_Vertical +RJ45 vertical connector https://www.on-shore.com/wp-content/uploads/PJ012-8P8CX.pdf +RJ45 PJ012 +0 +8 +8 +Connector_RJ +RJ45_Plug_Metz_AJP92A8813 +plug, ethernet, 8P8C, RJ45 Plug +AJP92A8813 8P8C RJ45 ethernet plug +0 +8 +8 +Connector_RJ +RJ45_Pulse_JK0654219NL_Horizontal +10/100/1000 Base-T RJ45 single port with LEDs https://media.digikey.com/pdf/Data%20Sheets/Pulse%20PDFs/JK%20Series.pdf#page=2 +RJ45 8p8c ethernet +0 +18 +17 +Connector_RJ +RJ45_Pulse_JXD6-0001NL_Horizontal +RJ45 ethernet transformer with magnetics (https://productfinder.pulseeng.com/doc_type/WEB301/doc_num/JXD6-0001NL/doc_part/JXD6-0001NL.pdf) +ethernet 8p8c transformer magjack +0 +12 +11 +Connector_RJ +RJ45_Wuerth_7499010001A_Horizontal +10/100Base-TX RJ45 ethernet magnetic transformer connector horizontal https://katalog.we-online.de/pbs/datasheet/7499010001A.pdf +RJ45 ethernet magnetic +0 +10 +9 +Connector_RJ +RJ45_Wuerth_7499010121A_Horizontal +10/100Base-TX RJ45 ethernet magnetic transformer connector horizontal with green/orange LEDs https://katalog.we-online.de/pbs/datasheet/7499010121A.pdf +RJ45 ethernet magnetic +0 +14 +13 +Connector_RJ +RJ45_Wuerth_7499111446_Horizontal +LAN-Transformer WE-RJ45LAN 10/100/1000 BaseT +ethernet lan connector +0 +16 +15 +Connector_RJ +RJ45_Wuerth_7499151120_Horizontal +Wuerth 7499151120, LAN-Transformer WE-RJ45LAN 10/100/1000 BaseT, Dual Ethernet Jack (http://katalog.we-online.de/pbs/datasheet/7499151120.pdf) +ethernet lan connector +0 +32 +29 +Connector_RJ +RJ45_Wuerth_74980111211_Horizontal +RJ45 LAN Transformer 10/100BaseT (https://katalog.we-online.de/pbs/datasheet/74980111211.pdf) +lan magnetics transformer +0 +14 +13 +Connector_SATA_SAS +SAS-mini_TEConnectivity_1888174_Vertical +36pin mini SAS connector, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=1888174&DocType=Customer+Drawing&DocLang=English +SAS mini connector +0 +44 +44 +Connector_SATA_SAS +SATA_Amphenol_10029364-001LF_Horizontal +https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10029364.pdf +SATA +0 +24 +23 +Connector_Samtec +Samtec_FMC_ASP-134486-01_10x40_P1.27mm_Vertical +http://suddendocs.samtec.com/prints/asp-134486-01-mkt.pdf +FMC HPC +0 +400 +400 +Connector_Samtec +Samtec_FMC_ASP-134602-01_10x40_P1.27mm_Vertical +https://www.marutsu.co.jp/contents/shop/marutsu/ds/asp-134602-01.pdf +FMC HPC +0 +400 +400 +Connector_Samtec +Samtec_FMC_ASP-134604-01_4x40_Vertical +http://www.samtec.com/standards/vita.aspx +FMC LPC VITA +0 +162 +160 +Connector_Samtec +Samtec_LSHM-105-xx.x-x-DV-N_2x05_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-105-xx.x-x-DV-N, 5 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +10 +10 +Connector_Samtec +Samtec_LSHM-105-xx.x-x-DV-S_2x05-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-105-xx.x-x-DV-S, 5 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +12 +11 +Connector_Samtec +Samtec_LSHM-110-xx.x-x-DV-N_2x10_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-110-xx.x-x-DV-N, 10 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +20 +20 +Connector_Samtec +Samtec_LSHM-110-xx.x-x-DV-S_2x10-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-110-xx.x-x-DV-S, 10 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +22 +21 +Connector_Samtec +Samtec_LSHM-120-xx.x-x-DV-N_2x20_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-120-xx.x-x-DV-N, 20 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +40 +40 +Connector_Samtec +Samtec_LSHM-120-xx.x-x-DV-S_2x20-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-120-xx.x-x-DV-S, 20 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +42 +41 +Connector_Samtec +Samtec_LSHM-130-xx.x-x-DV-N_2x30_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-130-xx.x-x-DV-N, 30 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +60 +60 +Connector_Samtec +Samtec_LSHM-130-xx.x-x-DV-S_2x30-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-130-xx.x-x-DV-S, 30 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +62 +61 +Connector_Samtec +Samtec_LSHM-140-xx.x-x-DV-N_2x40_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-140-xx.x-x-DV-N, 40 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +80 +80 +Connector_Samtec +Samtec_LSHM-140-xx.x-x-DV-S_2x40-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-140-xx.x-x-DV-S, 40 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +82 +81 +Connector_Samtec +Samtec_LSHM-150-xx.x-x-DV-N_2x50_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-150-xx.x-x-DV-N, 50 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +100 +100 +Connector_Samtec +Samtec_LSHM-150-xx.x-x-DV-S_2x50-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-150-xx.x-x-DV-S, 50 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +102 +101 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV-BE-LC_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV-BE-LC, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV-BE_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV-BE, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV-LC_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV-LC, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-102-02-xxx-DV_2x02_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-102-02-xxx-DV, 2 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +4 +4 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV-BE-LC_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV-BE-LC, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV-BE_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV-BE, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV-LC_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV-LC, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-103-02-xxx-DV_2x03_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-103-02-xxx-DV, 3 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +6 +6 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-A_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-A, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-BE-A_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-BE-A, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-BE-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-BE-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-BE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-BE, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-104-02-xxx-DV_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xxx-DV, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-A_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-A, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-BE-A_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-BE-A, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-BE-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-BE-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-BE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-BE, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-105-02-xxx-DV_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xxx-DV, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-A_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-A, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-BE-A_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-BE-A, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-BE-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-BE-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-BE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-BE, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-106-02-xxx-DV_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xxx-DV, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-A_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-A, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-BE-A_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-BE-A, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-BE-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-BE-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-BE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-BE, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-107-02-xxx-DV_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xxx-DV, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-A_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-A, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-BE-A_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-BE-A, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-BE-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-BE-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-BE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-BE, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-108-02-xxx-DV_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xxx-DV, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-A_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-A, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-BE-A_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-BE-A, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-BE-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-BE-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-BE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-BE, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-109-02-xxx-DV_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xxx-DV, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-A_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-A, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-BE-A_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-BE-A, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-BE-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-BE-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-BE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-BE, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-110-02-xxx-DV_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xxx-DV, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-A_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-A, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-BE-A_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-BE-A, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-BE-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-BE-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-BE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-BE, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-111-02-xxx-DV_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xxx-DV, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-A_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-A, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-BE-A_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-BE-A, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-BE-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-BE-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-BE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-BE, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-112-02-xxx-DV_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xxx-DV, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-A_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-A, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-BE-A_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-BE-A, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-BE-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-BE-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-BE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-BE, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-113-02-xxx-DV_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xxx-DV, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-A_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-A, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-BE-A_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-BE-A, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-BE-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-BE-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-BE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-BE, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-114-02-xxx-DV_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xxx-DV, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-A_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-A, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-BE-A_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-BE-A, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-BE-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-BE-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-BE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-BE, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-115-02-xxx-DV_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-A_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-A, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-BE-A_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-BE-A, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-BE-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-BE-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-BE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-BE, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-116-02-xxx-DV_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xxx-DV, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-A_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-A, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-BE-A_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-BE-A, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-BE-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-BE-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-BE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-BE, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-117-02-xxx-DV_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xxx-DV, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-A_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-A, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-BE-A_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-BE-A, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-BE-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-BE-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-BE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-BE, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-118-02-xxx-DV_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xxx-DV, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-A_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-A, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-BE-A_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-BE-A, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-BE-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-BE-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-BE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-BE, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-119-02-xxx-DV_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xxx-DV, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-A_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-A, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-BE-A_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-BE-A, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-BE-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-BE-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-BE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-BE, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-120-02-xxx-DV_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xxx-DV, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-A_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-A, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-BE-A_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-BE-A, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-BE-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-BE-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-BE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-BE, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-121-02-xxx-DV_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xxx-DV, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-A_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-A, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-BE-A_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-BE-A, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-BE-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-BE-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-BE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-BE, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-122-02-xxx-DV_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xxx-DV, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-A_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-A, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-BE-A_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-BE-A, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-BE-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-BE-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-BE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-BE, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-123-02-xxx-DV_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xxx-DV, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-A_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-A, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-BE-A_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-BE-A, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-BE-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-BE-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-BE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-BE, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-124-02-xxx-DV_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xxx-DV, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-A_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-A, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-BE-A_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-BE-A, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-BE-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-BE-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-BE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-BE, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-125-02-xxx-DV_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xxx-DV, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-A_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-A, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-BE-A_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-BE-A, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-BE-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-BE-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-BE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-BE, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-126-02-xxx-DV_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xxx-DV, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-A_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-A, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-BE-A_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-BE-A, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-BE-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-BE-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-BE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-BE, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-127-02-xxx-DV_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xxx-DV, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-A_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-A, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-BE-A_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE-A, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-BE-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-BE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-128-02-xxx-DV_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-A_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-A, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-BE-A_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-BE-A, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-BE-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-BE-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-BE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-BE, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-129-02-xxx-DV_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xxx-DV, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-A_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-A, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-BE-A_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-BE-A, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-BE-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-BE-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-BE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-BE, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-130-02-xxx-DV_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xxx-DV, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-A_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-A, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-BE-A_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-BE-A, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-BE-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-BE-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-BE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-BE, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-131-02-xxx-DV_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xxx-DV, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-A_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-A, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-BE-A_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-BE-A, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-BE-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-BE-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-BE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-BE, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-132-02-xxx-DV_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xxx-DV, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-A_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-A, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-BE-A_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-BE-A, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-BE-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-BE-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-BE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-BE, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-133-02-xxx-DV_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xxx-DV, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-A_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-A, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-BE-A_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-BE-A, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-BE-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-BE-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-BE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-BE, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-134-02-xxx-DV_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xxx-DV, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-A_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-A, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-BE-A_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-BE-A, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-BE-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-BE-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-BE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-BE, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-135-02-xxx-DV_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xxx-DV, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-A_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-A, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-BE-A_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-BE-A, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-BE-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-BE-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-BE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-BE, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-136-02-xxx-DV_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xxx-DV, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-A_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-A, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-BE-A_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-BE-A, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-BE-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-BE-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-BE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-BE, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-137-02-xxx-DV_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xxx-DV, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-A_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-A, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-BE-A_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-BE-A, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-BE-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-BE-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-BE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-BE, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-138-02-xxx-DV_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xxx-DV, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-A_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-A, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-BE-A_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-BE-A, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-BE-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-BE-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-BE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-BE, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-139-02-xxx-DV_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xxx-DV, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-A_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-A, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-BE-A_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-BE-A, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-BE-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-BE-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-BE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-BE, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-140-02-xxx-DV_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xxx-DV, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-A_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-A, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-BE-A_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-BE-A, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-BE-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-BE-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-BE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-BE, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-141-02-xxx-DV_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xxx-DV, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-A_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-A, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-BE-A_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-BE-A, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-BE-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-BE-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-BE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-BE, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-142-02-xxx-DV_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xxx-DV, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-A_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-A, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-BE-A_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-BE-A, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-BE-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-BE-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-BE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-BE, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-143-02-xxx-DV_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xxx-DV, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-A_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-A, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-BE-A_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-BE-A, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-BE-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-BE-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-BE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-BE, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-144-02-xxx-DV_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xxx-DV, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-A_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-A, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-BE-A_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-BE-A, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-BE-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-BE-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-BE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-BE, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-145-02-xxx-DV_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xxx-DV, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-A_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-A, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-BE-A_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-BE-A, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-BE-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-BE-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-BE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-BE, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-146-02-xxx-DV_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xxx-DV, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-A_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-A, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-BE-A_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-BE-A, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-BE-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-BE-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-BE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-BE, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-147-02-xxx-DV_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xxx-DV, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-A_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-A, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-BE-A_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-BE-A, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-BE-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-BE-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-BE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-BE, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-148-02-xxx-DV_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xxx-DV, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-A_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-A, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-BE-A_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-BE-A, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-BE-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-BE-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-BE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-BE, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-149-02-xxx-DV_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xxx-DV, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-A_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-A, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-BE-A_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-BE-A, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-BE-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-BE-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-BE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-BE, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_SMD +Samtec_HLE-150-02-xxx-DV_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xxx-DV, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-PE-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-PE-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-PE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-PE (compatible alternatives: HLE-104-02-xx-DV-PE-BE), 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-TE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-TE, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-PE-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-PE-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-PE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-PE (compatible alternatives: HLE-105-02-xx-DV-PE-BE), 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-TE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-TE, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-PE-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-PE-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-PE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-PE (compatible alternatives: HLE-106-02-xx-DV-PE-BE), 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-TE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-TE, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-PE-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-PE-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-PE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-PE (compatible alternatives: HLE-107-02-xx-DV-PE-BE), 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-TE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-TE, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-PE-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-PE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE (compatible alternatives: HLE-108-02-xx-DV-PE-BE), 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-TE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-TE, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-PE-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-PE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE (compatible alternatives: HLE-109-02-xx-DV-PE-BE), 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-TE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-TE, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-PE-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-PE-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-PE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-PE (compatible alternatives: HLE-110-02-xx-DV-PE-BE), 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-TE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-TE, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-PE-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-PE-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-PE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-PE (compatible alternatives: HLE-111-02-xx-DV-PE-BE), 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-TE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-TE, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-PE-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-PE-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-PE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-PE (compatible alternatives: HLE-112-02-xx-DV-PE-BE), 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-TE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-TE, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-PE-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-PE-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-PE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-PE (compatible alternatives: HLE-113-02-xx-DV-PE-BE), 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-TE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-TE, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-PE-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-PE-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-PE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-PE (compatible alternatives: HLE-114-02-xx-DV-PE-BE), 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-TE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-TE, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-PE-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-PE-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-PE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-PE (compatible alternatives: HLE-115-02-xx-DV-PE-BE), 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-TE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-TE, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-PE-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-PE-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-PE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-PE (compatible alternatives: HLE-116-02-xx-DV-PE-BE), 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-TE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-TE, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-PE-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-PE-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-PE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-PE (compatible alternatives: HLE-117-02-xx-DV-PE-BE), 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-TE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-TE, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-PE-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-PE-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-PE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-PE (compatible alternatives: HLE-118-02-xx-DV-PE-BE), 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-TE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-TE, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-PE-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-PE-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-PE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-PE (compatible alternatives: HLE-119-02-xx-DV-PE-BE), 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-TE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-TE, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-PE-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-PE-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-PE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-PE (compatible alternatives: HLE-120-02-xx-DV-PE-BE), 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-TE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-TE, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-PE-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-PE-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-PE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-PE (compatible alternatives: HLE-121-02-xx-DV-PE-BE), 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-TE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-TE, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-PE-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-PE-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-PE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-PE (compatible alternatives: HLE-122-02-xx-DV-PE-BE), 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-TE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-TE, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-PE-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-PE-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-PE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-PE (compatible alternatives: HLE-123-02-xx-DV-PE-BE), 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-TE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-TE, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-PE-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-PE-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-PE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-PE (compatible alternatives: HLE-124-02-xx-DV-PE-BE), 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-TE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-TE, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-PE-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-PE-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-PE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-PE (compatible alternatives: HLE-125-02-xx-DV-PE-BE), 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-TE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-TE, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-PE-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-PE-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-PE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-PE (compatible alternatives: HLE-126-02-xx-DV-PE-BE), 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-TE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-TE, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-PE-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-PE-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-PE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-PE (compatible alternatives: HLE-127-02-xx-DV-PE-BE), 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-TE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-TE, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-PE-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-PE-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-PE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-PE (compatible alternatives: HLE-128-02-xx-DV-PE-BE), 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-TE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-TE, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-PE-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-PE-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-PE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-PE (compatible alternatives: HLE-129-02-xx-DV-PE-BE), 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-TE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-TE, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-PE-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-PE-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-PE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-PE (compatible alternatives: HLE-130-02-xx-DV-PE-BE), 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-TE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-TE, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-PE-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-PE-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-PE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-PE (compatible alternatives: HLE-131-02-xx-DV-PE-BE), 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-TE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-TE, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-PE-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-PE-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-PE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-PE (compatible alternatives: HLE-132-02-xx-DV-PE-BE), 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-TE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-TE, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-PE-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-PE-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-PE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-PE (compatible alternatives: HLE-133-02-xx-DV-PE-BE), 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-TE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-TE, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-PE-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-PE-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-PE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-PE (compatible alternatives: HLE-134-02-xx-DV-PE-BE), 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-TE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-TE, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-PE-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-PE-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-PE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-PE (compatible alternatives: HLE-135-02-xx-DV-PE-BE), 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-TE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-TE, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-PE-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-PE-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-PE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-PE (compatible alternatives: HLE-136-02-xx-DV-PE-BE), 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-TE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-TE, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-PE-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-PE-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-PE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-PE (compatible alternatives: HLE-137-02-xx-DV-PE-BE), 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-TE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-TE, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-PE-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-PE-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-PE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-PE (compatible alternatives: HLE-138-02-xx-DV-PE-BE), 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-TE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-TE, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-PE-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-PE-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-PE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-PE (compatible alternatives: HLE-139-02-xx-DV-PE-BE), 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-TE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-TE, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-PE-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-PE-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-PE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-PE (compatible alternatives: HLE-140-02-xx-DV-PE-BE), 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-TE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-TE, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-PE-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-PE-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-PE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-PE (compatible alternatives: HLE-141-02-xx-DV-PE-BE), 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-TE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-TE, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-PE-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-PE-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-PE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-PE (compatible alternatives: HLE-142-02-xx-DV-PE-BE), 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-TE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-TE, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-PE-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-PE-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-PE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-PE (compatible alternatives: HLE-143-02-xx-DV-PE-BE), 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-TE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-TE, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-PE-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-PE-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-PE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-PE (compatible alternatives: HLE-144-02-xx-DV-PE-BE), 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-TE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-TE, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-PE-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-PE-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-PE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-PE (compatible alternatives: HLE-145-02-xx-DV-PE-BE), 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-TE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-TE, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-PE-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-PE-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-PE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-PE (compatible alternatives: HLE-146-02-xx-DV-PE-BE), 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-TE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-TE, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-PE-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-PE-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-PE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-PE (compatible alternatives: HLE-147-02-xx-DV-PE-BE), 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-TE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-TE, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-PE-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-PE-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-PE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-PE (compatible alternatives: HLE-148-02-xx-DV-PE-BE), 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-TE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-TE, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-PE-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-PE-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-PE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-PE (compatible alternatives: HLE-149-02-xx-DV-PE-BE), 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-TE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-TE, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-PE-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-PE-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-PE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-PE (compatible alternatives: HLE-150-02-xx-DV-PE-BE), 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-TE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-TE, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Stocko +Stocko_MKS_1651-6-0-202_1x2_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +2 +2 +Connector_Stocko +Stocko_MKS_1652-6-0-202_1x2_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +2 +2 +Connector_Stocko +Stocko_MKS_1653-6-0-303_1x3_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +3 +3 +Connector_Stocko +Stocko_MKS_1654-6-0-404_1x4_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +4 +4 +Connector_Stocko +Stocko_MKS_1655-6-0-505_1x5_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +5 +5 +Connector_Stocko +Stocko_MKS_1656-6-0-606_1x6_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +6 +6 +Connector_Stocko +Stocko_MKS_1657-6-0-707_1x7_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +7 +7 +Connector_Stocko +Stocko_MKS_1658-6-0-808_1x8_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +8 +8 +Connector_Stocko +Stocko_MKS_1659-6-0-909_1x9_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +9 +9 +Connector_Stocko +Stocko_MKS_1660-6-0-1010_1x10_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +10 +10 +Connector_Stocko +Stocko_MKS_1661-6-0-1111_1x11_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +11 +11 +Connector_Stocko +Stocko_MKS_1662-6-0-1212_1x12_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +12 +12 +Connector_Stocko +Stocko_MKS_1663-6-0-1313_1x13_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +13 +13 +Connector_Stocko +Stocko_MKS_1664-6-0-1414_1x14_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +14 +14 +Connector_Stocko +Stocko_MKS_1665-6-0-1515_1x15_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +15 +15 +Connector_Stocko +Stocko_MKS_1666-6-0-1616_1x16_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +16 +16 +Connector_Stocko +Stocko_MKS_1667-6-0-1717_1x17_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +17 +17 +Connector_Stocko +Stocko_MKS_1668-6-0-1818_1x18_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +18 +18 +Connector_Stocko +Stocko_MKS_1669-6-0-1919_1x19_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +19 +19 +Connector_Stocko +Stocko_MKS_1670-6-0-2020_1x20_P2.50mm_Vertical +Stocko MKS 16xx series connector, (https://www.stocko-contact.com/downloads/steckverbindersystem-raster-2,5-mm.pdf#page=15), generated with kicad-footprint-generator +Stocko RFK MKS 16xx +0 +20 +20 +Connector_TE-Connectivity +TE_1-826576-3_1x13_P3.96mm_Vertical +TE, 1-826576-3, 13 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +13 +13 +Connector_TE-Connectivity +TE_1-826576-5_1x15_P3.96mm_Vertical +TE, 1-826576-5, 15 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +15 +15 +Connector_TE-Connectivity +TE_1-826576-6_1x16_P3.96mm_Vertical +TE, 1-826576-6, 16 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +16 +16 +Connector_TE-Connectivity +TE_1-826576-7_1x17_P3.96mm_Vertical +TE, 1-826576-7, 17 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +17 +17 +Connector_TE-Connectivity +TE_1-826576-8_1x18_P3.96mm_Vertical +TE, 1-826576-8, 18 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +18 +18 +Connector_TE-Connectivity +TE_2-826576-0_1x20_P3.96mm_Vertical +TE, 2-826576-0, 20 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +20 +20 +Connector_TE-Connectivity +TE_3-826576-6_1x36_P3.96mm_Vertical +TE, 3-826576-6, 36 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +36 +36 +Connector_TE-Connectivity +TE_826576-2_1x02_P3.96mm_Vertical +TE, 826576-2, 2 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +2 +2 +Connector_TE-Connectivity +TE_826576-3_1x03_P3.96mm_Vertical +TE, 826576-3, 3 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +3 +3 +Connector_TE-Connectivity +TE_826576-5_1x05_P3.96mm_Vertical +TE, 826576-5, 5 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +5 +5 +Connector_TE-Connectivity +TE_826576-6_1x06_P3.96mm_Vertical +TE, 826576-6, 6 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +6 +6 +Connector_TE-Connectivity +TE_826576-7_1x07_P3.96mm_Vertical +TE, 826576-7, 7 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +7 +7 +Connector_TE-Connectivity +TE_826576-8_1x08_P3.96mm_Vertical +TE, 826576-8, 8 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +8 +8 +Connector_TE-Connectivity +TE_826576-9_1x09_P3.96mm_Vertical +TE, 826576-9, 9 Pins (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=826576&DocType=Customer+Drawing&DocLang=English), generated with kicad-footprint-generator +connector TE 826576 vertical +0 +9 +9 +Connector_TE-Connectivity +TE_5767171-1_2x19_P0.635mm_Vertical +PCB Mount Receptacle, Vertical, Board-to-Board, 38 Position, 24.003mm / .64mm [.945in] Centerline, Header Only, Palladium Nickel (https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F5767171%7FB2%7Fpdf%7FEnglish%7FENG_CD_5767171_B2.pdf%7F5767171-1#page=2) +mictor38 receptacle board-to-board +0 +43 +39 +Connector_TE-Connectivity +TE_AMPSEAL_1-776087-x_3Rows_23_P0.4mm_Horizontal +Connector +TE 776087 +0 +23 +23 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770182-x_3x03_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770182-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +9 +9 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770186-x_3x04_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770186-x, 4 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +12 +12 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770190-x_3x05_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770190-x, 5 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +15 +15 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770621-x_2x06_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770621-x, 6 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +12 +12 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770858-x_2x05_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770858-x, 5 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +10 +10 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770866-x_1x02_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770866-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +2 +2 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770870-x_1x03_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770870-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +3 +3 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770874-x_2x02_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770874-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +4 +4 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770875-x_2x03_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770875-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +6 +6 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770966-x_1x02_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770966-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +2 +2 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770967-x_1x03_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770967-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +3 +3 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770968-x_2x02_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770968-x, 2 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +4 +4 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770969-x_2x03_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770969-x, 3 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +6 +6 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770970-x_2x04_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770970-x, 4 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +8 +8 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770971-x_2x05_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770971-x, 5 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +10 +10 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770972-x_2x06_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770972-x, 6 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +12 +12 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770973-x_2x07_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770973-x, 7 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +14 +14 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-770974-x_2x08_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-770974-x, 8 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +16 +16 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794067-x_2x07_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794067-x, 7 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +14 +14 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794068-x_2x08_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794068-x, 8 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +16 +16 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794069-x_2x09_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794069-x, 9 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +18 +18 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794070-x_2x10_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794070-x, 10 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +20 +20 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794071-x_2x11_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794071-x, 11 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +22 +22 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794072-x_2x12_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794072-x, 12 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +24 +24 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794073-x_2x04_P4.14mm_Vertical +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794073-x, 4 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK side entry +0 +8 +8 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794105-x_2x09_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794105-x, 9 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +18 +18 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794106-x_2x10_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794106-x, 10 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +20 +20 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794107-x_2x11_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794107-x, 11 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +22 +22 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794108-x_2x12_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794108-x, 12 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +24 +24 +Connector_TE-Connectivity +TE_MATE-N-LOK_1-794374-x_1x01_P4.14mm_Horizontal +Molex Mini-Universal MATE-N-LOK, old mpn/engineering number: 1-794374-x, 1 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator +connector TE MATE-N-LOK top entry +0 +1 +1 +Connector_TE-Connectivity +TE_MATE-N-LOK_350211-1_1x04_P5.08mm_Vertical +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F350211%7FU5%7Fpdf%7FEnglish%7FENG_CD_350211_U5.pdf%7F350211-1 +connector TE MATE-N-LOK top entry ATA PATA IDE 5.25 inch floppy drive power +0 +4 +4 +Connector_USB +USB3_A_Molex_48393-001 +USB 3.0, type A, right angle (http://www.molex.com/pdm_docs/sd/483930003_sd.pdf) +USB 3.0 type A right angle +0 +13 +10 +Connector_USB +USB3_A_Plug_Wuerth_692112030100_Horizontal +USB3 type A Plug, Horizontal, http://katalog.we-online.de/em/datasheet/692112030100.pdf +usb A plug horizontal +0 +11 +10 +Connector_USB +USB_A_CNCTech_1001-011-01101_Horizontal +USB type A Plug, Horizontal, http://cnctech.us/pdfs/1001-011-01101.pdf +USB-A +0 +6 +5 +Connector_USB +USB_A_CONNFLY_DS1095-WNR0 +http://www.connfly.com/userfiles/image/UpLoadFile/File/2013/5/6/DS1095.pdf +USB-A receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_A_Molex_67643_Horizontal +USB type A, Horizontal, https://www.molex.com/pdm_docs/sd/676433910_sd.pdf +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_Molex_105057_Vertical +https://www.molex.com/pdm_docs/sd/1050570001_sd.pdf +USB A Vertical +0 +7 +5 +Connector_USB +USB_A_Stewart_SS-52100-001_Horizontal +USB A connector https://belfuse.com/resources/drawings/stewartconnector/dr-stw-ss-52100-001.pdf +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_Wuerth_614004134726_Horizontal +USB A connector https://www.we-online.com/catalog/datasheet/614004134726.pdf +USB_A Female Connector receptacle +0 +8 +5 +Connector_USB +USB_A_Wuerth_61400826021_Horizontal_Stacked +Stacked USB A connector http://katalog.we-online.de/em/datasheet/61400826021.pdf +Wuerth stacked USB_A +0 +12 +9 +Connector_USB +USB_B_Amphenol_MUSB-D511_Vertical_Rugged +A,phenol MUSB_D511, USB B female connector, straight, rugged, https://www.amphenolcanada.com/ProductSearch/drawings/AC/MUSBD511XX.pdf +USB_B_MUSB_Straight female connector straight rugged MUSB D511 +0 +6 +5 +Connector_USB +USB_B_Lumberg_2411_02_Horizontal +USB 2.0 receptacle type B, horizontal version, through-hole, https://downloads.lumberg.com/datenblaetter/en/2411_02.pdf +USB B receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_B_OST_USB-B1HSxx_Horizontal +USB B receptacle, Horizontal, through-hole, http://www.on-shore.com/wp-content/uploads/2015/09/usb-b1hsxx.pdf +USB-B receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_B_TE_5787834_Vertical +http://www.mouser.com/ds/2/418/NG_CD_5787834_A4-669110.pdf +USB_B USB B vertical female connector +0 +6 +5 +Connector_USB +USB_C_Plug_JAE_DX07P024AJ1 +Universal Serial Bus (USB) Shielded I/O Plug, Type C, Right Angle, Surface Mount, https://www.jae.com/en/searchfilter/?topics_keyword=DX07P024AJ1&mainItemSelect=1 +USB Type-C Plug Edge Mount +0 +30 +25 +Connector_USB +USB_C_Plug_Molex_105444 +Universal Serial Bus (USB) Shielded I/O Plug, Type C, Right Angle, Surface Mount, http://www.molex.com/pdm_docs/sd/1054440001_sd.pdf +USB Type-C Plug Edge Mount +0 +24 +23 +Connector_USB +USB_C_Receptacle_Amphenol_12401548E4-2A +USB TYPE C, RA RCPT PCB, Hybrid, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401548E4%7e2A +USB C Type-C Receptacle Hybrid +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401548E4-2A_CircularHoles +USB TYPE C, RA RCPT PCB, Hybrid, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401548E4%7e2A +USB C Type-C Receptacle Hybrid +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401610E4-2A +USB TYPE C, RA RCPT PCB, SMT, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401610E4%7e2A +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401610E4-2A_CircularHoles +USB TYPE C, RA RCPT PCB, SMT, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401610E4%7e2A +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_GCT_USB4085 +USB 2.0 Type C Receptacle, https://gct.co/Files/Drawings/USB4085.pdf +USB Type-C Receptacle Through-hole Right angle +0 +20 +17 +Connector_USB +USB_C_Receptacle_HRO_TYPE-C-31-M-12 +USB Type-C receptacle for USB 2.0 and PD, http://www.krhro.com/uploads/soft/180320/1-1P320120243.pdf +usb usb-c 2.0 pd +0 +20 +17 +Connector_USB +USB_C_Receptacle_JAE_DX07S024WJ1R350 +http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ117219.pdf +USB C Type-C Receptacle SMD +0 +30 +25 +Connector_USB +USB_C_Receptacle_JAE_DX07S024WJ3R400 +USB TYPE C, VERT RCPT PCB, SMT, http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ117928.pdf +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_Palconn_UTC16-G +http://www.palpilot.com/wp-content/uploads/2017/05/UTC027-GKN-OR-Rev-A.pdf +USB C Type-C Receptacle USB2.0 +0 +20 +17 +Connector_USB +USB_C_Receptacle_XKB_U262-16XN-4BVC11 +USB Type C, right-angle, SMT, https://datasheet.lcsc.com/szlcsc/1811141824_XKB-Enterprise-U262-161N-4BVC11_C319148.pdf +USB C Type-C Receptacle SMD +0 +20 +17 +Connector_USB +USB_Micro-AB_Molex_47590-0001 +Micro USB AB receptable, right-angle inverted (https://www.molex.com/pdm_docs/sd/475900001_sd.pdf) +Micro AB USB SMD +0 +14 +6 +Connector_USB +USB_Micro-B_Amphenol_10103594-0001LF_Horizontal +Micro USB Type B 10103594-0001LF, http://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10103594.pdf +USB USB_B USB_micro USB_OTG +0 +17 +6 +Connector_USB +USB_Micro-B_Amphenol_10104110_Horizontal +USB Micro-B, horizontal, https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10104110.pdf +USB Micro B horizontal +0 +9 +6 +Connector_USB +USB_Micro-B_Amphenol_10118194_Horizontal +USB Micro-B receptacle, horizontal, SMD, 10118194, https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10118194.pdf +USB Micro B horizontal SMD +0 +17 +6 +Connector_USB +USB_Micro-B_GCT_USB3076-30-A +GCT Micro USB https://gct.co/files/drawings/usb3076.pdf +Micro-USB SMD Typ-B GCT +0 +11 +6 +Connector_USB +USB_Micro-B_Molex-105017-0001 +http://www.molex.com/pdm_docs/sd/1050170001_sd.pdf +Micro-USB SMD Typ-B +0 +13 +6 +Connector_USB +USB_Micro-B_Molex-105133-0001 +Molex Vertical Micro USB Typ-B (http://www.molex.com/pdm_docs/sd/1051330001_sd.pdf) +Micro-USB SMD Typ-B Vertical +0 +8 +6 +Connector_USB +USB_Micro-B_Molex-105133-0031 +Molex Vertical Micro USB Typ-B (http://www.molex.com/pdm_docs/sd/1051330031_sd.pdf) +Micro-USB SMD Typ-B Vertical +0 +8 +6 +Connector_USB +USB_Micro-B_Molex_47346-0001 +Micro USB B receptable with flange, bottom-mount, SMD, right-angle (http://www.molex.com/pdm_docs/sd/473460001_sd.pdf) +Micro B USB SMD +0 +11 +6 +Connector_USB +USB_Micro-B_Wuerth_614105150721_Vertical +USB Micro-B receptacle, through-hole, vertical, http://katalog.we-online.de/em/datasheet/614105150721.pdf +usb micro receptacle vertical +0 +7 +6 +Connector_USB +USB_Micro-B_Wuerth_614105150721_Vertical_CircularHoles +USB Micro-B receptacle, through-hole, vertical, http://katalog.we-online.de/em/datasheet/614105150721.pdf +usb micro receptacle vertical +0 +7 +6 +Connector_USB +USB_Micro-B_Wuerth_629105150521 +USB Micro-B receptacle, http://www.mouser.com/ds/2/445/629105150521-469306.pdf +usb micro receptacle +0 +9 +6 +Connector_USB +USB_Micro-B_Wuerth_629105150521_CircularHoles +USB Micro-B receptacle, http://www.mouser.com/ds/2/445/629105150521-469306.pdf +usb micro receptacle +0 +9 +6 +Connector_USB +USB_Mini-B_AdamTech_MUSB-B5-S-VT-TSMT-1_SMD_Vertical +http://www.adam-tech.com/upload/MUSB-B5-S-VT-TSMT-1.pdf +USB Mini-B +0 +7 +6 +Connector_USB +USB_Mini-B_Lumberg_2486_01_Horizontal +USB Mini-B 5-pin SMD connector, http://downloads.lumberg.com/datenblaetter/en/2486_01.pdf +USB USB_B USB_Mini connector +0 +9 +6 +Connector_USB +USB_Mini-B_Tensility_54-00023_Vertical +http://www.tensility.com/pdffiles/54-00023.pdf +usb mini receptacle vertical +0 +7 +6 +Connector_USB +USB_Mini-B_Tensility_54-00023_Vertical_CircularHoles +http://www.tensility.com/pdffiles/54-00023.pdf +usb mini receptacle vertical +0 +7 +6 +Connector_USB +USB_Mini-B_Wuerth_65100516121_Horizontal +Mini USB 2.0 Type B SMT Horizontal 5 Contacts (https://katalog.we-online.de/em/datasheet/65100516121.pdf) +Mini USB 2.0 Type B +0 +9 +6 +Connector_Wago +Wago_734-132_1x02_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-132 , 2 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +2 +2 +Connector_Wago +Wago_734-133_1x03_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-133 , 3 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +3 +3 +Connector_Wago +Wago_734-134_1x04_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-134 , 4 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +4 +4 +Connector_Wago +Wago_734-135_1x05_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-135 , 5 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +5 +5 +Connector_Wago +Wago_734-136_1x06_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-136 , 6 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +6 +6 +Connector_Wago +Wago_734-137_1x07_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-137 , 7 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +7 +7 +Connector_Wago +Wago_734-138_1x08_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-138 , 8 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +8 +8 +Connector_Wago +Wago_734-139_1x09_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-139 , 9 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +9 +9 +Connector_Wago +Wago_734-140_1x10_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-140 , 10 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +10 +10 +Connector_Wago +Wago_734-141_1x11_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-141 , 11 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +11 +11 +Connector_Wago +Wago_734-142_1x12_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-142 , 12 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +12 +12 +Connector_Wago +Wago_734-143_1x13_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-143 , 13 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +13 +13 +Connector_Wago +Wago_734-144_1x14_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-144 , 14 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +14 +14 +Connector_Wago +Wago_734-146_1x16_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-146 , 16 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +16 +16 +Connector_Wago +Wago_734-148_1x18_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-148 , 18 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +18 +18 +Connector_Wago +Wago_734-150_1x20_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-150 , 20 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +20 +20 +Connector_Wago +Wago_734-154_1x24_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-154 , 24 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +24 +24 +Connector_Wago +Wago_734-162_1x02_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-162 , 2 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +2 +2 +Connector_Wago +Wago_734-163_1x03_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-163 , 3 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +3 +3 +Connector_Wago +Wago_734-164_1x04_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-164 , 4 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +4 +4 +Connector_Wago +Wago_734-165_1x05_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-165 , 5 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +5 +5 +Connector_Wago +Wago_734-166_1x06_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-166 , 6 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +6 +6 +Connector_Wago +Wago_734-167_1x07_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-167 , 7 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +7 +7 +Connector_Wago +Wago_734-168_1x08_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-168 , 8 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +8 +8 +Connector_Wago +Wago_734-169_1x09_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-169 , 9 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +9 +9 +Connector_Wago +Wago_734-170_1x10_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-170 , 10 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +10 +10 +Connector_Wago +Wago_734-171_1x11_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-171 , 11 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +11 +11 +Connector_Wago +Wago_734-172_1x12_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-172 , 12 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +12 +12 +Connector_Wago +Wago_734-173_1x13_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-173 , 13 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +13 +13 +Connector_Wago +Wago_734-174_1x14_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-174 , 14 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +14 +14 +Connector_Wago +Wago_734-176_1x16_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-176 , 16 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +16 +16 +Connector_Wago +Wago_734-178_1x18_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-178 , 18 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +18 +18 +Connector_Wago +Wago_734-180_1x20_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-180 , 20 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +20 +20 +Connector_Wago +Wago_734-184_1x24_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-184 , 24 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +24 +24 +Connector_Wire +SolderWire-0.1sqmm_1x01_D0.4mm_OD1mm +Soldered wire connection, for a single 0.1 mm² wire, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.1sqmm_1x01_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.1 mm² wire, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.1sqmm_1x01_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.1 mm² wire, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.1sqmm_1x02_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 2 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.1sqmm_1x02_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.1sqmm_1x02_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.1sqmm_1x03_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 3 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.1sqmm_1x03_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.1sqmm_1x03_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.1sqmm_1x04_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 4 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.1sqmm_1x04_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.1sqmm_1x04_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.1sqmm_1x05_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 5 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.1sqmm_1x05_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.1sqmm_1x05_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.1sqmm_1x06_P3.6mm_D0.4mm_OD1mm +Soldered wire connection, for 6 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.1sqmm_1x06_P3.6mm_D0.4mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.1sqmm_1x06_P3.6mm_D0.4mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.1 mm² wires, basic insulation, conductor diameter 0.4mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 0.1 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.1sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.1mm +Soldered wire connection, for a single 0.5 mm² wire, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.5 mm² wire, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.5 mm² wire, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.3mm +Soldered wire connection, for a single 0.5 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.5 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x01_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.5 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 2 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 2 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x02_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 3 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 3 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x03_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 4 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 4 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x04_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 5 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x05_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.6mm_D0.9mm_OD2.1mm +Soldered wire connection, for 6 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.6mm_D0.9mm_OD2.1mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.6mm_D0.9mm_OD2.1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.5 mm² wires, basic insulation, conductor diameter 0.9mm, outer diameter 2.1mm, size source Multi-Contact FLEXI-E 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.8mm_D0.9mm_OD2.3mm +Soldered wire connection, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.8mm_D0.9mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.5sqmm_1x06_P4.8mm_D0.9mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-xV 0.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.15sqmm_1x01_D0.5mm_OD1.5mm +Soldered wire connection, for a single 0.15 mm² wire, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.15sqmm_1x01_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.15 mm² wire, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.15sqmm_1x01_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.15 mm² wire, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.15sqmm_1x02_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 2 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.15sqmm_1x02_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.15sqmm_1x02_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.15sqmm_1x03_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 3 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.15sqmm_1x03_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.15sqmm_1x03_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.15sqmm_1x04_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 4 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.15sqmm_1x04_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.15sqmm_1x04_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.15sqmm_1x05_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 5 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.15sqmm_1x05_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.15sqmm_1x05_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.15sqmm_1x06_P4mm_D0.5mm_OD1.5mm +Soldered wire connection, for 6 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.15sqmm_1x06_P4mm_D0.5mm_OD1.5mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.15sqmm_1x06_P4mm_D0.5mm_OD1.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.15 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.15sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD1.7mm +Soldered wire connection, for a single 0.25 mm² wire, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.25 mm² wire, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.25 mm² wire, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD2mm +Soldered wire connection, for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x01_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 2 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 2 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x02_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 3 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 3 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x03_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 4 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 4 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x04_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 5 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 5 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x05_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.2mm_D0.65mm_OD1.7mm +Soldered wire connection, for 6 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.2mm_D0.65mm_OD1.7mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.2mm_D0.65mm_OD1.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.25 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 1.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.5mm_D0.65mm_OD2mm +Soldered wire connection, for 6 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.5mm_D0.65mm_OD2mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.25sqmm_1x06_P4.5mm_D0.65mm_OD2mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.25 mm² wires, reinforced insulation, conductor diameter 0.65mm, outer diameter 2mm, size source Multi-Contact FLEXI-2V 0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.25sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD2.3mm +Soldered wire connection, for a single 0.75 mm² wire, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.75 mm² wire, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.75 mm² wire, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD3.5mm +Soldered wire connection, for a single 0.75 mm² wire, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.75 mm² wire, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x01_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.75 mm² wire, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.75sqmm_1x02_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 2 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x02_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.75sqmm_1x03_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 3 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 3 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x03_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.75sqmm_1x04_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 4 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 4 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x04_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.75sqmm_1x05_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 5 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x05_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.75sqmm_1x06_P4.8mm_D1.25mm_OD2.3mm +Soldered wire connection, for 6 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P4.8mm_D1.25mm_OD2.3mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P4.8mm_D1.25mm_OD2.3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.75 mm² wires, basic insulation, conductor diameter 1.25mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P7mm_D1.25mm_OD3.5mm +Soldered wire connection, for 6 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P7mm_D1.25mm_OD3.5mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.75sqmm_1x06_P7mm_D1.25mm_OD3.5mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.75 mm² wires, reinforced insulation, conductor diameter 1.25mm, outer diameter 3.5mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.75sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.127sqmm_1x01_D0.48mm_OD1mm +Soldered wire connection, for a single 0.127 mm² wire, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +1 +1 +Connector_Wire +SolderWire-0.127sqmm_1x01_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for a single 0.127 mm² wire, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.127sqmm_1x01_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 0.127 mm² wire, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-0.127sqmm_1x02_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 2 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +2 +2 +Connector_Wire +SolderWire-0.127sqmm_1x02_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.127sqmm_1x02_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-0.127sqmm_1x03_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 3 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +3 +3 +Connector_Wire +SolderWire-0.127sqmm_1x03_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.127sqmm_1x03_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-0.127sqmm_1x04_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 4 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +4 +4 +Connector_Wire +SolderWire-0.127sqmm_1x04_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.127sqmm_1x04_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-0.127sqmm_1x05_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 5 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +5 +5 +Connector_Wire +SolderWire-0.127sqmm_1x05_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.127sqmm_1x05_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-0.127sqmm_1x06_P3.7mm_D0.48mm_OD1mm +Soldered wire connection, for 6 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm +0 +6 +6 +Connector_Wire +SolderWire-0.127sqmm_1x06_P3.7mm_D0.48mm_OD1mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-0.127sqmm_1x06_P3.7mm_D0.48mm_OD1mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 0.127 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 1mm, size source Multi-Contact FLEXI-E/HK 0.127 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 0.127sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3.9mm +Soldered wire connection, for a single 1.5 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for a single 1.5 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1.5 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3mm +Soldered wire connection, for a single 1.5 mm² wire, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for a single 1.5 mm² wire, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x01_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1.5 mm² wire, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1.5sqmm_1x02_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 2 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 2 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x02_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1.5sqmm_1x03_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 3 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 3 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x03_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1.5sqmm_1x04_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 4 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 4 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x04_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1.5sqmm_1x05_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 5 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 5 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x05_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1.5sqmm_1x06_P6mm_D1.7mm_OD3mm +Soldered wire connection, for 6 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P6mm_D1.7mm_OD3mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P6mm_D1.7mm_OD3mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1.5 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 3mm, size source Multi-Contact FLEXI-E 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P7.8mm_D1.7mm_OD3.9mm +Soldered wire connection, for 6 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P7.8mm_D1.7mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1.5sqmm_1x06_P7.8mm_D1.7mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1.5 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD2.7mm +Soldered wire connection, for a single 1 mm² wire, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for a single 1 mm² wire, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1 mm² wire, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD3.9mm +Soldered wire connection, for a single 1 mm² wire, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for a single 1 mm² wire, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x01_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 1 mm² wire, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-1sqmm_1x02_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 2 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 2 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x02_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-1sqmm_1x03_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 3 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 3 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x03_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-1sqmm_1x04_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 4 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 4 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x04_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-1sqmm_1x05_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 5 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 5 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x05_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-1sqmm_1x06_P5.4mm_D1.4mm_OD2.7mm +Soldered wire connection, for 6 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P5.4mm_D1.4mm_OD2.7mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P5.4mm_D1.4mm_OD2.7mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P7.8mm_D1.4mm_OD3.9mm +Soldered wire connection, for 6 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P7.8mm_D1.4mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-1sqmm_1x06_P7.8mm_D1.4mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 1 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 1.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 1sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD3.6mm +Soldered wire connection, for a single 2.5 mm² wire, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for a single 2.5 mm² wire, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 2.5 mm² wire, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD4.4mm +Soldered wire connection, for a single 2.5 mm² wire, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for a single 2.5 mm² wire, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x01_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 2.5 mm² wire, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2.5sqmm_1x02_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 2 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 2 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x02_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2.5sqmm_1x03_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 3 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 3 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x03_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2.5sqmm_1x04_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 4 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 4 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x04_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2.5sqmm_1x05_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 5 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 5 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x05_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2.5sqmm_1x06_P7.2mm_D2.4mm_OD3.6mm +Soldered wire connection, for 6 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P7.2mm_D2.4mm_OD3.6mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P7.2mm_D2.4mm_OD3.6mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 2.5 mm² wires, basic insulation, conductor diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P8.8mm_D2.4mm_OD4.4mm +Soldered wire connection, for 6 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P8.8mm_D2.4mm_OD4.4mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2.5sqmm_1x06_P8.8mm_D2.4mm_OD4.4mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 2.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2.5sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2sqmm_1x01_D2mm_OD3.9mm +Soldered wire connection, for a single 2 mm² wire, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +1 +1 +Connector_Wire +SolderWire-2sqmm_1x01_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for a single 2 mm² wire, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2sqmm_1x01_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for a single 2 mm² wire, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +1 +1 +Connector_Wire +SolderWire-2sqmm_1x02_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 2 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +2 +2 +Connector_Wire +SolderWire-2sqmm_1x02_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 2 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2sqmm_1x02_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 2 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +2 +2 +Connector_Wire +SolderWire-2sqmm_1x03_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 3 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +3 +3 +Connector_Wire +SolderWire-2sqmm_1x03_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 3 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2sqmm_1x03_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 3 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +3 +3 +Connector_Wire +SolderWire-2sqmm_1x04_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 4 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +4 +4 +Connector_Wire +SolderWire-2sqmm_1x04_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 4 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2sqmm_1x04_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 4 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +4 +4 +Connector_Wire +SolderWire-2sqmm_1x05_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 5 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +5 +5 +Connector_Wire +SolderWire-2sqmm_1x05_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 5 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2sqmm_1x05_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 5 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +5 +5 +Connector_Wire +SolderWire-2sqmm_1x06_P7.8mm_D2mm_OD3.9mm +Soldered wire connection, for 6 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm +0 +6 +6 +Connector_Wire +SolderWire-2sqmm_1x06_P7.8mm_D2mm_OD3.9mm_Relief +Soldered wire connection with feed through strain relief, for 6 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm strain-relief +0 +6 +6 +Connector_Wire +SolderWire-2sqmm_1x06_P7.8mm_D2mm_OD3.9mm_Relief2x +Soldered wire connection with double feed through strain relief, for 6 times 2 mm² wires, reinforced insulation, conductor diameter 2mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator +connector wire 2sqmm double-strain-relief +0 +6 +6 +Connector_Wire +SolderWirePad_1x01_SMD_1x2mm +Wire Pad, Square, SMD Pad, 5mm x 10mm, +MesurementPoint Square SMDPad 5mmx10mm +0 +1 +1 +Connector_Wire +SolderWirePad_1x01_SMD_5x10mm +Wire Pad, Square, SMD Pad, 5mm x 10mm, +MesurementPoint Square SMDPad 5mmx10mm +0 +1 +1 +Connector_Wuerth +Wuerth_WR-WTB_64800211622_1x02_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800211622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +2 +2 +Connector_Wuerth +Wuerth_WR-WTB_64800311622_1x03_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800311622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +3 +3 +Connector_Wuerth +Wuerth_WR-WTB_64800411622_1x04_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800411622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +4 +4 +Connector_Wuerth +Wuerth_WR-WTB_64800511622_1x05_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800511622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +5 +5 +Connector_Wuerth +Wuerth_WR-WTB_64800611622_1x06_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800611622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +6 +6 +Connector_Wuerth +Wuerth_WR-WTB_64800711622_1x07_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800711622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +7 +7 +Connector_Wuerth +Wuerth_WR-WTB_64800811622_1x08_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800811622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +8 +8 +Connector_Wuerth +Wuerth_WR-WTB_64800911622_1x09_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64800911622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +9 +9 +Connector_Wuerth +Wuerth_WR-WTB_64801011622_1x10_P1.50mm_Vertical +Wuerth WR-WTB series connector, 64801011622 (https://katalog.we-online.com/em/datasheet/6480xx11622.pdf), generated with kicad-footprint-generator +connector Wuerth WR-WTB vertical +0 +10 +10 +Converter_ACDC +Converter_ACDC_CUI_PBO-3-Sxx_THT_Vertical +ACDC-Converter, 3W, CUI PBO-3, THT https://www.cui.com/product/resource/pbo-3.pdf +Converter AC-DC THT Vertical +0 +6 +6 +Converter_ACDC +Converter_ACDC_Hahn_HS-400xx_THT +ACDC-Converter, 3W, Hahn-HS-400xx, THT https://www.schukat.com/schukat/schukat_cms_de.nsf/index/FrameView?OpenDocument&art=HS40009&wg=M7942 +Hahn ACDC-Converter THT +0 +4 +4 +Converter_ACDC +Converter_ACDC_HiLink_HLK-PMxx +ACDC-Converter, 3W, HiLink, HLK-PMxx, THT, http://www.hlktech.net/product_detail.php?ProId=54 +ACDC-Converter 3W THT HiLink board mount module +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-02-xx_SMD +ACDC-Converter, 3W, Meanwell, IRM-02, SMD, https://www.meanwell.com/Upload/PDF/IRM-02/IRM-02-SPEC.PDF +ACDC-Converter 3W +0 +14 +14 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-02-xx_THT +ACDC-Converter, 2W, Meanwell, IRM-02, THT, https://www.meanwell.co.uk/media/productPDF/IRM-02-spec.pdf +ACDC-Converter 2W THT +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-03-xx_SMD +ACDC-Converter, 3W, Meanwell, IRM-03, SMD, http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-03 +ACDC-Converter 3W +0 +14 +14 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-03-xx_THT +ACDC-Converter, 3W, Meanwell, IRM-03, THT, https://www.meanwell.com/Upload/PDF/IRM-03/IRM-03-SPEC.PDF +ACDC-Converter 3W THT +0 +5 +5 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-05-xx_THT +http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-05 +ACDC-Converter 5W Meanwell IRM-05 +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-10-xx_THT +http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-10 +ACDC-Converter 10W Meanwell IRM-10 +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-20-xx_THT +ACDC-Converter, 20W, Meanwell, IRM-20, THT http://www.meanwell.com/webapp/product/search.aspx?prod=IRM-20 +ACDC-Converter 20W Meanwell IRM-20 +0 +4 +4 +Converter_ACDC +Converter_ACDC_MeanWell_IRM-60-xx_THT +ACDC-Converter, 50-60W, Meanwell, IRM-60, THT https://www.meanwellusa.com/productPdf.aspx?i=687 +switching power supply +0 +4 +4 +Converter_ACDC +Converter_ACDC_RECOM_RAC01-xxSGB_THT +https://www.recom-power.com/pdf/Powerline-AC-DC/RAC01-GB.pdf +recom power ac dc rac01xxgb rac01-05sgb rac01-12sgb +0 +4 +4 +Converter_ACDC +Converter_ACDC_RECOM_RAC04-xxSGx_THT +https://www.recom-power.com/pdf/Powerline-AC-DC/RAC04-GA.pdf +recom power ac dc +0 +5 +5 +Converter_ACDC +Converter_ACDC_RECOM_RAC05-xxSK_THT +https://www.recom-power.com/pdf/Powerline-AC-DC/RAC05-K.pdf +recom power ac dc +0 +5 +5 +Converter_ACDC +Converter_ACDC_TRACO_TMG-15_THT +ACDC-Converter, TRACO, TMG Series 15 https://www.tracopower.com/products/tmg.pdf +ACDC-Converter TRACO TMG Series 15 +0 +4 +4 +Converter_ACDC +Converter_ACDC_TRACO_TMLM-04_THT +ACDC-Converter, TRACO, TMLM Series 04 https://www.tracopower.com/products/tmlm.pdf +ACDC-Converter TRACO TMLM Series 04 +0 +7 +7 +Converter_ACDC +Converter_ACDC_TRACO_TMLM-05_THT +ACDC-Converter, TRACO TMLM 05,https://www.tracopower.com/products/tmlm.pdf +ACDC-Converter TRACO TMLM 05 +0 +4 +4 +Converter_ACDC +Converter_ACDC_TRACO_TMLM-10-20_THT +ACDC-Converter, TRACO TMLM 10, TRACO TMLM 20, https://www.tracopower.com/products/tmlm.pdf +ACDC-Converter TRACO TMLM 10 and TMLM 20 +0 +4 +4 +Converter_ACDC +Converter_ACDC_Vigortronix_VTX-214-010-xxx_THT +Vigortronix VTX-214-010-xxx serie of ACDC converter, http://www.vigortronix.com/10WattACDCPCBPowerModule.aspx +Vigortronix VTX-214-010-xxx serie of ACDC converter +0 +4 +4 +Converter_ACDC +Converter_ACDC_Vigortronix_VTX-214-015-1xx_THT +Vigortronix VTX-214-010-xxx serie of ACDC converter, http://www.vigortronix.com/10WattACDCPCBPowerModule.aspx +Vigortronix VTX-214-010-xxx serie of ACDC converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_Artesyn_ATA_SMD +DCDC-Converter, Artesyn, ATA Series, 3W Single and Dual Output, 1500VDC Isolation, 24.0x13.7x8.0mm https://www.artesyn.com/power/assets/ata_series_ds_01apr2015_79c25814fd.pdf https://www.artesyn.com/power/assets/trn_dc-dc_ata_3w_series_releas1430412818_techref.pdf +DCDC SMD +0 +7 +7 +Converter_DCDC +Converter_DCDC_Bothhand_CFUDxxxx_THT +DCDC-Converter, BOTHHAND, Type CFxxxx-Serie, (Very dodgy url but was the only at hand), +DCDC-Converter BOTHHAND Type CFxxxx-Serie +0 +10 +10 +Converter_DCDC +Converter_DCDC_Bothhand_CFUSxxxxEH_THT +DCDC-Converter, BOTHHAND, Type CFxxxx-Serie, (Very dodgy url but was the only at hand), +DCDC-Converter BOTHHAND Type CFxxxx-Serie +0 +9 +9 +Converter_DCDC +Converter_DCDC_Bothhand_CFUSxxxx_THT +DCDC-Converter, BOTHHAND, Type CFxxxx-Serie, (Very dodgy url but was the only at hand), +DCDC-Converter BOTHHAND Type CFxxxx-Serie +0 +8 +8 +Converter_DCDC +Converter_DCDC_Cincon_EC5BExx_Dual_THT +DCDC-Converter, CINCON, EC5BExx, 18-36VDC to Dual output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/B%20CASE/SPEC-EC5BE-V24.pdf +DCDC-Converter CINCON EC5BExx 18-36VDC to Dual output +0 +6 +6 +Converter_DCDC +Converter_DCDC_Cincon_EC5BExx_Single_THT +DCDC-Converter, CINCON, EC5BExx, 18-36VDC to dual output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/B%20CASE/SPEC-EC5BE-V24.pdf +DCDC-Converter CINCON EC5BExx 18-36VDC to dual output +0 +4 +4 +Converter_DCDC +Converter_DCDC_Cincon_EC6Cxx_Dual-Triple_THT +DCDC-Converter, CINCON, EC6Cxx, dual or tripple output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/C%20CASE/SPEC-EC6C-V12.pdf +DCDC-Converter CINCON EC6Cxx dual or tripple output +0 +7 +7 +Converter_DCDC +Converter_DCDC_Cincon_EC6Cxx_Single_THT +DCDC-Converter, CINCON, EC6Cxx, single output, http://www.cincon.com/upload/media/data%20sheets/Data%20Sheet%20(DC)/C%20CASE/SPEC-EC6C-V12.pdf +DCDC-Converter CINCON EC6Cxx single output +0 +6 +6 +Converter_DCDC +Converter_DCDC_Cyntec_MUN12AD01-SH +http://www.cyntec.com/upfile/products/download/Cyntec%20MUN12AD01-SH_Datasheet.pdf +Power Module uPOL MUN12AD01 +0 +13 +9 +Converter_DCDC +Converter_DCDC_Cyntec_MUN12AD03-SH +http://www.cyntec.com/upfile/products/download/Cyntec%20MUN12AD03-SH_Datasheet.pdf +Power Module uPOL MUN12AD03 +0 +19 +11 +Converter_DCDC +Converter_DCDC_MeanWell_NID30_THT +Meanwell DCDC non-isolated converter SIP module, http://www.meanwell.com/webapp/product/search.aspx?prod=nid30 +DCDC non-isolated converter +0 +11 +11 +Converter_DCDC +Converter_DCDC_MeanWell_NID60_THT +MeanWell NID60, http://www.meanwell.com/Upload/PDF/NID60/NID60-SPEC.PDF +MeanWell NID60 +0 +11 +11 +Converter_DCDC +Converter_DCDC_Murata_MEE1SxxxxSC_THT +https://power.murata.com/pub/data/power/ncl/kdc_mee1.pdf +murata dc-dc transformer +0 +4 +4 +Converter_DCDC +Converter_DCDC_Murata_MEE3SxxxxSC_THT +https://power.murata.com/pub/data/power/ncl/kdc_mee3.pdf +murata dc-dc transformer +0 +4 +4 +Converter_DCDC +Converter_DCDC_Murata_MGJ2DxxxxxxSC_THT +Murata MGJ2DxxxxxxSC, 19.5x9.8x12.5mm, 5.2kVDC Isolated, 2W, SIP package style, https://power.murata.com/data/power/ncl/kdc_mgj2.pdf +Murata MGJ2DxxxxxxSC +0 +5 +5 +Converter_DCDC +Converter_DCDC_Murata_MGJ3 +Murata MGJ3, 5.2kVDC Isolated 3W Gate Drive, 15V/5V/5V Configurable, 22.61x23.11x14.19mm, https://power.murata.com/datasheet?/data/power/ncl/kdc_mgj3.pdf +DCDC SMD +0 +7 +7 +Converter_DCDC +Converter_DCDC_Murata_NCS1SxxxxSC_THT +Murata NCS1SxxxxSC https://power.murata.com/data/power/ncl/kdc_ncs1.pdf (Script generated with StandardBox.py) (Murata NCS1SxxxxSC https://power.murata.com/data/power/ncl/kdc_ncs1.pdf) +Murata NCS1SxxxxSC +0 +5 +5 +Converter_DCDC +Converter_DCDC_RECOM_R-78B-2.0_THT +DCDC-Converter, RECOM, RECOM_R-78B-2.0, SIP-3, pitch 2.54mm, package size 11.5x8.5x17.5mm^3, https://www.recom-power.com/pdf/Innoline/R-78Bxx-2.0.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78E-0.5_THT +DCDC-Converter, RECOM, RECOM_R-78E-0.5, SIP-3, pitch 2.54mm, package size 11.6x8.5x10.4mm^3, https://www.recom-power.com/pdf/Innoline/R-78Exx-0.5.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78HB-0.5L_THT +DCDC-Converter, RECOM, RECOM_R-78HB-0.5L, SIP-3, Horizontally Mounted, pitch 2.54mm, package size 11.5x8.5x17.5mm^3, https://www.recom-power.com/pdf/Innoline/R-78HBxx-0.5_L.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78HB-0.5_THT +DCDC-Converter, RECOM, RECOM_R-78HB-0.5, SIP-3, pitch 2.54mm, package size 11.5x8.5x17.5mm^3, https://www.recom-power.com/pdf/Innoline/R-78HBxx-0.5_L.pdf +dc-dc recom buck sip-3 pitch 2.54mm +0 +3 +3 +Converter_DCDC +Converter_DCDC_RECOM_R-78S-0.1_THT +DCDC-Converter, RECOM, RECOM_R-78S-0.1, SIP-4, pitch 2.54mm, package size 11.6x8.5x10.4mm^3, https://www.recom-power.com/pdf/Innoline/R-78Sxx-0.1.pdf +dc-dc recom buck sip-4 pitch 2.54mm +0 +4 +4 +Converter_DCDC +Converter_DCDC_RECOM_R5xxxDA_THT +DCDC-Converter, RECOM, RECOM_R5xxxDA, SIP-12, Horizontally Mounted, pitch 2.54mm, package size 32.2x9.1x15mm^3, https://www.recom-power.com/pdf/Innoline/R-5xxxPA_DA.pdf +dc-dc recom buck sip-12 pitch 2.54mm +0 +12 +12 +Converter_DCDC +Converter_DCDC_RECOM_R5xxxPA_THT +DCDC-Converter, RECOM, RECOM_R5xxxPA, SIP-12, pitch 2.54mm, package size 32.2x9.1x15mm^3, https://www.recom-power.com/pdf/Innoline/R-5xxxPA_DA.pdf +dc-dc recom buck sip-12 pitch 2.54mm +0 +12 +12 +Converter_DCDC +Converter_DCDC_RECOM_RPA60-xxxxSFW +RPA60-FW 60W Isolated DC to DC Converters +DCDC Regulator Single +0 +6 +6 +Converter_DCDC +Converter_DCDC_RECOM_RPMx.x-x.0 +https://www.recom-power.com/pdf/Innoline/RPM-6.0.pdf +dc-dc recom buck lga-25 pitch 2.29mm +0 +25 +25 +Converter_DCDC +Converter_DCDC_TRACO_TDN_5-xxxxWISM_SMD +Traco TDN 5WISM Series, 5W, SMD (https://assets.tracopower.com/20200225170127/TDN5WISM/documents/tdn5wism-datasheet.pdf#page=3) +dcdc traco 5w smd +0 +6 +6 +Converter_DCDC +Converter_DCDC_TRACO_TEN10-xxxx_Dual_THT +DCDC-Converter, TRACO, TEN10-xxxx, single output, https://assets.tracopower.com/20171102100522/TEN10/documents/ten10-datasheet.pdf +DCDC-Converter TRACO TEN10-xxxx single output +0 +5 +5 +Converter_DCDC +Converter_DCDC_TRACO_TEN10-xxxx_Single_THT +DCDC-Converter, TRACO, TEN10-xxxx, single output, https://assets.tracopower.com/20171102100522/TEN10/documents/ten10-datasheet.pdf +DCDC-Converter TRACO TEN10-xxxx single output +0 +4 +4 +Converter_DCDC +Converter_DCDC_TRACO_TEN10-xxxx_THT +DCDC-Converter, TRACO, TEN10-xxxx, https://assets.tracopower.com/20171102100522/TEN10/documents/ten10-datasheet.pdf +DCDC-Converter TRACO TEN10-xxxx +0 +4 +4 +Converter_DCDC +Converter_DCDC_TRACO_TEN20-xxxx-N4_THT +DCDC-Converter TRACO TEN20 Generic, https://assets.tracopower.com/20171102100522/TEN20/documents/ten20-datasheet.pdf +DCDC-Converter TRACO TEN20 Generic +0 +5 +5 +Converter_DCDC +Converter_DCDC_TRACO_TEN20-xxxx_THT +DCDC-Converter TRACO TEN20 Generic, https://assets.tracopower.com/20171102100522/TEN20/documents/ten20-datasheet.pdf +DCDC-Converter TRACO TEN20 Generic +0 +6 +6 +Converter_DCDC +Converter_DCDC_TRACO_THD_15-xxxxWIN_THT +Traco THD 15WIN, 15W, THT (https://www.tracopower.com/products/thd15win.pdf#page=3) +traco dcdc tht 15w +0 +9 +9 +Converter_DCDC +Converter_DCDC_TRACO_TMR-1-xxxx_Dual_THT +DCDC-Converter, TRACO, TMR 1-xxxx, Dual output, Rev. March 21.2016 +DCDC-Converter TRACO TMR1-xxxx Dual_output +0 +5 +5 +Converter_DCDC +Converter_DCDC_TRACO_TMR-1-xxxx_Single_THT +DCDC-Converter, TRACO, TMR 1-xxxx, Single output, Rev. March 21.2016 +DCDC-Converter TRACO TMR1-xxxx Single_output +0 +4 +4 +Converter_DCDC +Converter_DCDC_TRACO_TMR-1SM_SMD +http://assets.tracopower.com/TMR1SM/documents/tmr1sm-datasheet.pdf +DCDC SMD TRACO TMR-1SM +0 +7 +7 +Converter_DCDC +Converter_DCDC_TRACO_TMR-2xxxxWI_THT +https://www.tracopower.com/products/tmr2wi.pdf +DCDC-Converter TRACO TMRxxxxWI Single/Dual_output +0 +7 +7 +Converter_DCDC +Converter_DCDC_TRACO_TMR-xxxx_THT +DCDC-Converter, TRACO, TMR xxxx, Single/Dual output, http://www.datasheetlib.com/datasheet/135136/tmr-2-2410e_traco-power.html?page=3#datasheet +DCDC-Converter TRACO TMRxxxx Single/Dual_output +0 +7 +7 +Converter_DCDC +Converter_DCDC_TRACO_TSR-1_THT +DCDC-Converter, TRACO, TSR 1-xxxx +DCDC-Converter TRACO TSR-1 +0 +3 +3 +Converter_DCDC +Converter_DCDC_XP_POWER-IA48xxD_THT +XP_POWER IA48xxD, DIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IA48xxD DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IA48xxS_THT +XP_POWER IA48xxS, SIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IA48xxS SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-IAxxxxD_THT +XP_POWER IAxxxxD, DIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IAxxxxD DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IAxxxxS_THT +XP_POWER IAxxxxS, SIP, (https://www.xppower.com/pdfs/SF_IA.pdf), generated with kicad-footprint-generator +XP_POWER IAxxxxS SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxDH_THT +XP_POWER IHxxxxDH, DIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxDH DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxD_THT +XP_POWER IHxxxxD, DIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxD DIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxSH_THT +XP_POWER IHxxxxSH, SIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxSH SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-IHxxxxS_THT +XP_POWER IHxxxxS, SIP, (https://www.xppower.com/pdfs/SF_IH.pdf), generated with kicad-footprint-generator +XP_POWER IHxxxxS SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-ISU02_SMD +DCDC-Converter, XP POWER, ISU02 Series, 2W Single and Dual Output, 1500VDC Isolation, 19.0x17.0x8.7mm https://www.xppower.com/Portals/0/pdfs/SF_ISU02.pdf +DCDC SMD XP POWER ISU02 +0 +7 +7 +Converter_DCDC +Converter_DCDC_XP_POWER-ITQxxxxS-H_THT +XP_POWER ITQxxxxS-H, SIP, (https://www.xppower.com/pdfs/SF_ITQ.pdf), generated with kicad-footprint-generator +XP_POWER ITQxxxxS-H SIP DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER-ITXxxxxSA_THT +XP_POWER ITXxxxxSA, SIP, (https://www.xppower.com/pdfs/SF_ITX.pdf), generated with kicad-footprint-generator +XP_POWER ITXxxxxSA SIP DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_XP_POWER-ITxxxxxS_THT +XP_POWER ITxxxxxS, SIP, (https://www.xppower.com/portals/0/pdfs/SF_ITX.pdf https://www.xppower.com/portals/0/pdfs/SF_ITQ.pdf), generated with kicad-footprint-generator +XP_POWER ITxxxxxS SIP DCDC-Converter +0 +7 +7 +Converter_DCDC +Converter_DCDC_XP_POWER_JTDxxxxxxx_THT +XP Power JTD Series DC-DC Converter +DCDC Isolated +0 +6 +6 +Converter_DCDC +Converter_DCDC_XP_POWER_JTExxxxDxx_THT +DCDC-Converter, XP POWER, Type JTE06 Series, Dual Output +DCDC-Converter XP_POWER JTE06 Dual +0 +8 +8 +Converter_DCDC +Converter_DCDC_muRata_CRE1xxxxxx3C_THT +Isolated 1W single output DC/DC, http://power.murata.com/data/power/ncl/kdc_cre1.pdf +Isolated 1W single output DC/DC +0 +4 +4 +Converter_DCDC +Converter_DCDC_muRata_CRE1xxxxxxDC_THT +Isloated DC-DC, http://power.murata.com/data/power/ncl/kdc_cre1.pdf +Isloated DC-DC +0 +4 +4 +Converter_DCDC +Converter_DCDC_muRata_CRE1xxxxxxSC_THT +http://power.murata.com/data/power/ncl/kdc_cre1.pdf +murata dc-dc transformer +0 +4 +4 +Converter_DCDC +Converter_DCDC_muRata_NMAxxxxDC_THT +Isolated 1W DCDC-Converter, http://power.murata.com/data/power/ncl/kdc_nma.pdf +Isolated 1W DCDC-Converter +0 +6 +6 +Converter_DCDC +Converter_DCDC_muRata_NMAxxxxSC_THT +muRata NMAxxxxSC footprint based on SIP7, http://power.murata.com/data/power/ncl/kdc_nma.pdf +muRata NMAxxxxSC DCDC-Converter +0 +5 +5 +Converter_DCDC +Converter_DCDC_muRata_NXExSxxxxMC_SMD +Isolated 1W or 2W Single Output SM DC/DC Converters http://power.murata.com/data/power/ncl/kdc_nxe1.pdf http://power.murata.com/data/power/ncl/kdc_nxe2.pdf +Isolated 1W or 2W Single Output SM DC/DC Converters +0 +5 +5 +Converter_DCDC +Converter_DCDC_muRata_OKI-78SR_Horizontal +https://power.murata.com/data/power/oki-78sr.pdf +78sr3.3 78sr5 78sr9 78sr12 78srXX +0 +3 +3 +Converter_DCDC +Converter_DCDC_muRata_OKI-78SR_Vertical +https://power.murata.com/data/power/oki-78sr.pdf +78sr3.3 78sr5 78sr9 78sr12 78srXX +0 +3 +3 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Horizontal +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +2 +2 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Horizontal_1EP_style1 +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +3 +3 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Horizontal_1EP_style2 +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +5 +3 +Crystal +Crystal_AT310_D3.0mm_L10.0mm_Vertical +Crystal THT AT310 10.0mm-10.5mm length 3.0mm diameter http://www.cinetech.com.tw/upload/2011/04/20110401165201.pdf +['AT310'] +0 +2 +2 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Horizontal +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +2 +2 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Horizontal_1EP_style1 +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +3 +3 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Horizontal_1EP_style2 +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +5 +3 +Crystal +Crystal_C26-LF_D2.1mm_L6.5mm_Vertical +Crystal THT C26-LF 6.5mm length 2.06mm diameter +['C26-LF'] +0 +2 +2 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Horizontal +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +2 +2 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Horizontal_1EP_style1 +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +3 +3 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Horizontal_1EP_style2 +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +5 +3 +Crystal +Crystal_C38-LF_D3.0mm_L8.0mm_Vertical +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +2 +2 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Horizontal +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +2 +2 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Horizontal_1EP_style1 +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +3 +3 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Horizontal_1EP_style2 +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +5 +3 +Crystal +Crystal_DS10_D1.0mm_L4.3mm_Vertical +Crystal THT DS10 4.3mm length 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +2 +2 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Horizontal +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +2 +2 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Horizontal_1EP_style1 +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +3 +3 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Horizontal_1EP_style2 +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +5 +3 +Crystal +Crystal_DS15_D1.5mm_L5.0mm_Vertical +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +2 +2 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Horizontal +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +2 +2 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Horizontal_1EP_style1 +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +3 +3 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Horizontal_1EP_style2 +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +5 +3 +Crystal +Crystal_DS26_D2.0mm_L6.0mm_Vertical +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +2 +2 +Crystal +Crystal_HC18-U_Horizontal +Crystal THT HC-18/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC18-U_Horizontal_1EP_style1 +Crystal THT HC-18/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC18-U_Horizontal_1EP_style2 +Crystal THT HC-18/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC18-U_Vertical +Crystal THT HC-18/U, http://5hertz.com/pdfs/04404_D.pdf +THT crystalHC-18/U +0 +2 +2 +Crystal +Crystal_HC33-U_Horizontal +Crystal THT HC-33/U http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC33-U_Horizontal_1EP_style1 +Crystal THT HC-33/U http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC33-U_Horizontal_1EP_style2 +Crystal THT HC-33/U http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC33-U_Vertical +Crystal THT HC-33/U, http://pdi.bentech-taiwan.com/PDI/GEN20SPEV20HC3320U.pdf +THT crystalHC-33/U +0 +2 +2 +Crystal +Crystal_HC35-U +Crystal, Quarz, HC35/U, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/TO71xx.pdf +Crystal Quarz HC35/U +0 +3 +3 +Crystal +Crystal_HC49-4H_Vertical +Crystal THT HC-49-4H http://5hertz.com/pdfs/04404_D.pdf +THT crystalHC-49-4H +0 +2 +2 +Crystal +Crystal_HC49-U-3Pin_Vertical +Crystal THT HC-49/U, 3pin-version, http://www.raltron.com/products/pdfspecs/crystal_hc_49_45_51.pdf +THT crystalHC-49/U +0 +3 +3 +Crystal +Crystal_HC49-U_Horizontal +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC49-U_Horizontal_1EP_style1 +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC49-U_Horizontal_1EP_style2 +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC49-U_Vertical +Crystal THT HC-49/U http://5hertz.com/pdfs/04404_D.pdf +THT crystalHC-49/U +0 +2 +2 +Crystal +Crystal_HC50_Horizontal +Crystal THT HC-50 http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC50_Horizontal_1EP_style1 +Crystal THT HC-50 http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC50_Horizontal_1EP_style2 +Crystal THT HC-50 http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC50_Vertical +Crystal THT HC-50, http://www.crovencrystals.com/croven_pdf/HC-50_Crystal_Holder_Rev_00.pdf +THT crystalHC-50 +0 +2 +2 +Crystal +Crystal_HC51-U_Vertical +Crystal THT HC-51/U, http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystalHC-51/U +0 +2 +2 +Crystal +Crystal_HC51_Horizontal +Crystal THT HC-51 http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC51_Horizontal_1EP_style1 +Crystal THT HC-51 http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC51_Horizontal_1EP_style2 +Crystal THT HC-51 http://www.crovencrystals.com/croven_pdf/HC-51_Crystal_Holder_Rev_00.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-6mm_Horizontal +Crystal THT HC-51/6mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC52-6mm_Horizontal_1EP_style1 +Crystal THT HC-51/6mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC52-6mm_Horizontal_1EP_style2 +Crystal THT HC-51/6mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-6mm_Vertical +Crystal THT HC-52/6mm, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystalHC-49/U +0 +2 +2 +Crystal +Crystal_HC52-8mm_Horizontal +Crystal THT HC-51/8mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC52-8mm_Horizontal_1EP_style1 +Crystal THT HC-51/8mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC52-8mm_Horizontal_1EP_style2 +Crystal THT HC-51/8mm http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-8mm_Vertical +Crystal THT HC-52/8mm, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystalHC-49/U +0 +2 +2 +Crystal +Crystal_HC52-U-3Pin_Vertical +Crystal THT HC-52/U, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystalHC-52/U +0 +3 +3 +Crystal +Crystal_HC52-U_Horizontal +Crystal THT HC-51/U http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +2 +2 +Crystal +Crystal_HC52-U_Horizontal_1EP_style1 +Crystal THT HC-51/U http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +3 +3 +Crystal +Crystal_HC52-U_Horizontal_1EP_style2 +Crystal THT HC-51/U http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal +0 +5 +3 +Crystal +Crystal_HC52-U_Vertical +Crystal THT HC-52/U, http://www.kvg-gmbh.de/assets/uploads/files/product_pdfs/XS71xx.pdf +THT crystal HC-52/U +0 +2 +2 +Crystal +Crystal_Round_D1.0mm_Vertical +Crystal THT DS10 1.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS10'] +0 +2 +2 +Crystal +Crystal_Round_D1.5mm_Vertical +Crystal THT DS15 5.0mm length 1.5mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS15'] +0 +2 +2 +Crystal +Crystal_Round_D2.0mm_Vertical +Crystal THT DS26 6.0mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/DS-Series.pdf +['DS26'] +0 +2 +2 +Crystal +Crystal_Round_D3.0mm_Vertical +Crystal THT C38-LF 8.0mm length 3.0mm diameter +['C38-LF'] +0 +2 +2 +Crystal +Crystal_SMD_0603-2Pin_6.0x3.5mm +SMD Crystal SERIES SMD0603/2 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-2.pdf, 6.0x3.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_0603-2Pin_6.0x3.5mm_HandSoldering +SMD Crystal SERIES SMD0603/2 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-2.pdf, hand-soldering, 6.0x3.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_0603-4Pin_6.0x3.5mm +SMD Crystal SERIES SMD0603/4 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-4.pdf, 6.0x3.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_0603-4Pin_6.0x3.5mm_HandSoldering +SMD Crystal SERIES SMD0603/4 http://www.petermann-technik.de/fileadmin/petermann/pdf/SMD0603-4.pdf, hand-soldering, 6.0x3.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_2012-2Pin_2.0x1.2mm +SMD Crystal 2012/2 http://txccrystal.com/images/pdf/9ht11.pdf, 2.0x1.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_2012-2Pin_2.0x1.2mm_HandSoldering +SMD Crystal 2012/2 http://txccrystal.com/images/pdf/9ht11.pdf, hand-soldering, 2.0x1.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_2016-4Pin_2.0x1.6mm +SMD Crystal SERIES SMD2016/4 http://www.q-crystal.com/upload/5/2015552223166229.pdf, 2.0x1.6mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_2520-4Pin_2.5x2.0mm +SMD Crystal SERIES SMD2520/4 http://www.newxtal.com/UploadFiles/Images/2012-11-12-09-29-09-776.pdf, 2.5x2.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_3215-2Pin_3.2x1.5mm +SMD Crystal FC-135 https://support.epson.biz/td/api/doc_check.php?dl=brief_FC-135R_en.pdf +SMD SMT Crystal +0 +2 +2 +Crystal +Crystal_SMD_3225-4Pin_3.2x2.5mm +SMD Crystal SERIES SMD3225/4 http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_3225-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal SERIES SMD3225/4 http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_5032-2Pin_5.0x3.2mm +SMD Crystal SERIES SMD2520/2 http://www.icbase.com/File/PDF/HKC/HKC00061008.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_5032-2Pin_5.0x3.2mm_HandSoldering +SMD Crystal SERIES SMD2520/2 http://www.icbase.com/File/PDF/HKC/HKC00061008.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_5032-4Pin_5.0x3.2mm +SMD Crystal SERIES SMD2520/4 http://www.icbase.com/File/PDF/HKC/HKC00061008.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_7050-2Pin_7.0x5.0mm +SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_7050-2Pin_7.0x5.0mm_HandSoldering +SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_7050-4Pin_7.0x5.0mm +SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM3-2Pin_5.0x3.2mm +Abracon Miniature Ceramic Smd Crystal ABM3 http://www.abracon.com/Resonators/abm3.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_Abracon_ABM3-2Pin_5.0x3.2mm_HandSoldering +Abracon Miniature Ceramic Smd Crystal ABM3 http://www.abracon.com/Resonators/abm3.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_Abracon_ABM3B-4Pin_5.0x3.2mm +Abracon Miniature Ceramic Smd Crystal ABM3B http://www.abracon.com/Resonators/abm3b.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM3C-4Pin_5.0x3.2mm +Abracon Miniature Ceramic Smd Crystal ABM3C http://www.abracon.com/Resonators/abm3c.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM7-2Pin_6.0x3.5mm +SMD Crystal Abracon ABM7, https://abracon.com/Resonators/abm7.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_Abracon_ABM8G-4Pin_3.2x2.5mm +Abracon Miniature Ceramic Smd Crystal ABM8G http://www.abracon.com/Resonators/ABM8G.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABM10-4Pin_2.5x2.0mm +Abracon Miniature Ceramic Smd Crystal ABM10 http://www.abracon.com/Resonators/ABM10.pdf +SMD SMT crystal Abracon ABM10 +0 +4 +4 +Crystal +Crystal_SMD_Abracon_ABS25-4Pin_8.0x3.8mm +Abracon Miniature Ceramic SMD Crystal ABS25 https://abracon.com/Resonators/abs25.pdf, 8.0x3.8mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_ECS_CSM3X-2Pin_7.6x4.1mm +http://www.ecsxtal.com/store/pdf/CSM-3X.pdf +Crystal CSM-3X +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_EQ161-2Pin_3.2x1.5mm +SMD Crystal EuroQuartz EQ161 series http://cdn-reichelt.de/documents/datenblatt/B400/PG32768C.pdf, 3.2x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_EQ161-2Pin_3.2x1.5mm_HandSoldering +SMD Crystal EuroQuartz EQ161 series http://cdn-reichelt.de/documents/datenblatt/B400/PG32768C.pdf, hand-soldering, 3.2x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_MJ-4Pin_5.0x3.2mm +SMD Crystal EuroQuartz MJ series http://cdn-reichelt.de/documents/datenblatt/B400/MJ.pdf, 5.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MJ-4Pin_5.0x3.2mm_HandSoldering +SMD Crystal EuroQuartz MJ series http://cdn-reichelt.de/documents/datenblatt/B400/MJ.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MQ-4Pin_7.0x5.0mm +SMD Crystal EuroQuartz MQ series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MQ-4Pin_7.0x5.0mm_HandSoldering +SMD Crystal EuroQuartz MQ series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MQ2-2Pin_7.0x5.0mm +SMD Crystal EuroQuartz MQ2 series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_MQ2-2Pin_7.0x5.0mm_HandSoldering +SMD Crystal EuroQuartz MQ2 series http://cdn-reichelt.de/documents/datenblatt/B400/MQ.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_EuroQuartz_MT-4Pin_3.2x2.5mm +SMD Crystal EuroQuartz MT series http://cdn-reichelt.de/documents/datenblatt/B400/MT.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_MT-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal EuroQuartz MT series http://cdn-reichelt.de/documents/datenblatt/B400/MT.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_X22-4Pin_2.5x2.0mm +SMD Crystal EuroQuartz X22 series http://cdn-reichelt.de/documents/datenblatt/B400/DS_X22.pdf, 2.5x2.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_EuroQuartz_X22-4Pin_2.5x2.0mm_HandSoldering +SMD Crystal EuroQuartz X22 series http://cdn-reichelt.de/documents/datenblatt/B400/DS_X22.pdf, hand-soldering, 2.5x2.0mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_FOX_FE-2Pin_7.5x5.0mm +crystal Ceramic Resin Sealed SMD http://www.foxonline.com/pdfs/fe.pdf, 7.5x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_FOX_FE-2Pin_7.5x5.0mm_HandSoldering +crystal Ceramic Resin Sealed SMD http://www.foxonline.com/pdfs/fe.pdf, hand-soldering, 7.5x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_FOX_FQ7050-2Pin_7.0x5.0mm +FOX SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_FOX_FQ7050-2Pin_7.0x5.0mm_HandSoldering +FOX SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_FOX_FQ7050-4Pin_7.0x5.0mm +FOX SMD Crystal SERIES SMD7050/4 https://www.foxonline.com/pdfs/FQ7050.pdf, 7.0x5.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_FrontierElectronics_FM206 +SMD Watch Crystal FrontierElectronics FM206 6.0mm length 1.9mm diameter http://www.chinafronter.com/wp-content/uploads/2013/12/FM206.pdf +['FM206'] +0 +3 +3 +Crystal +Crystal_SMD_G8-2Pin_3.2x1.5mm +SMD Crystal G8, 3.2x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_G8-2Pin_3.2x1.5mm_HandSoldering +SMD Crystal G8, hand-soldering, 3.2x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_HC49-SD +SMD Crystal HC-49-SD http://cdn-reichelt.de/documents/datenblatt/B400/xxx-HC49-SMD.pdf, 11.4x4.7mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_HC49-SD_HandSoldering +SMD Crystal HC-49-SD http://cdn-reichelt.de/documents/datenblatt/B400/xxx-HC49-SMD.pdf, hand-soldering, 11.4x4.7mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC1V-T1A-2Pin_8.0x3.7mm +SMD Crystal MicroCrystal CC1V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC1V-T1A.pdf, 8.0x3.7mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC1V-T1A-2Pin_8.0x3.7mm_HandSoldering +SMD Crystal MicroCrystal CC1V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC1V-T1A.pdf, hand-soldering, 8.0x3.7mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC4V-T1A-2Pin_5.0x1.9mm +SMD Crystal MicroCrystal CC4V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC4V-T1A.pdf, 5.0x1.9mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC4V-T1A-2Pin_5.0x1.9mm_HandSoldering +SMD Crystal MicroCrystal CC4V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC4V-T1A.pdf, hand-soldering, 5.0x1.9mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC5V-T1A-2Pin_4.1x1.5mm +SMD Crystal MicroCrystal CC5V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC5V-T1A.pdf, 4.1x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC5V-T1A-2Pin_4.1x1.5mm_HandSoldering +SMD Crystal MicroCrystal CC5V-T1A series http://cdn-reichelt.de/documents/datenblatt/B400/CC5V-T1A.pdf, hand-soldering, 4.1x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC7V-T1A-2Pin_3.2x1.5mm +SMD Crystal MicroCrystal CC7V-T1A/CM7V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC7V-T1A.pdf, 3.2x1.5mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC7V-T1A-2Pin_3.2x1.5mm_HandSoldering +SMD Crystal MicroCrystal CC7V-T1A/CM7V-T1A series http://www.microcrystal.com/images/_Product-Documentation/01_TF_ceramic_Packages/01_Datasheet/CC1V-T1A.pdf, hand-soldering, 3.2x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC8V-T1A-2Pin_2.0x1.2mm +SMD Crystal MicroCrystal CC8V-T1A/CM8V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CC8V-T1A.pdf, 2.0x1.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CC8V-T1A-2Pin_2.0x1.2mm_HandSoldering +SMD Crystal MicroCrystal CC8V-T1A/CM8V-T1A series http://www.microcrystal.com/images/_Product-Documentation/01_TF_ceramic_Packages/01_Datasheet/CC8V-T1A.pdf, hand-soldering, 2.0x1.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CM9V-T1A-2Pin_1.6x1.0mm +SMD Crystal MicroCrystal CM9V-T1A series https://www.microcrystal.com/fileadmin/Media/Products/32kHz/Datasheet/CM9V-T1A.pdf, 1.6x1.0mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_CM9V-T1A-2Pin_1.6x1.0mm_HandSoldering +SMD Crystal MicroCrystal CM9V-T1A series http://www.microcrystal.com/images/_Product-Documentation/01_TF_ceramic_Packages/01_Datasheet/CM9V-T1A.pdf, hand-soldering, 1.6x1.0mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_MicroCrystal_MS1V-T1K +SMD Watch Crystal MicroCrystal MS1V-T1K 6.1mm length 2.0mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/MS1V-T1K.pdf +['MS1V-T1K'] +0 +3 +3 +Crystal +Crystal_SMD_MicroCrystal_MS3V-T1R +SMD Watch Crystal MicroCrystal MS3V-T1R 5.2mm length 1.4mm diameter http://www.microcrystal.com/images/_Product-Documentation/03_TF_metal_Packages/01_Datasheet/MS3V-T1R.pdf +['MS3V-T1R'] +0 +3 +3 +Crystal +Crystal_SMD_Qantek_QC5CB-2Pin_5x3.2mm +SMD Crystal Qantek QC5CB, https://www.qantek.com/tl_files/products/crystals/QC5CB.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_FA238-4Pin_3.2x2.5mm +crystal Epson Toyocom FA-238 https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_FA238-4Pin_3.2x2.5mm_HandSoldering +crystal Epson Toyocom FA-238 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_FA238V-4Pin_3.2x2.5mm +crystal Epson Toyocom FA-238 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_FA238V-4Pin_3.2x2.5mm_HandSoldering +crystal Epson Toyocom FA-238 series http://www.mouser.com/ds/2/137/1721499-465440.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA406-4Pin_11.7x4.0mm +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, 11.7x4.0mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA406-4Pin_11.7x4.0mm_HandSoldering +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, hand-soldering, 11.7x4.0mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA505-2Pin_12.7x5.1mm +SMD Crystal Seiko Epson MC-505 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, 12.7x5.1mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MA505-2Pin_12.7x5.1mm_HandSoldering +SMD Crystal Seiko Epson MC-505 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, hand-soldering, 12.7x5.1mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MA506-4Pin_12.7x5.1mm +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, 12.7x5.1mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MA506-4Pin_12.7x5.1mm_HandSoldering +SMD Crystal Seiko Epson MC-506 http://media.digikey.com/pdf/Data%20Sheets/Epson%20PDFs/MA-505,506.pdf, hand-soldering, 12.7x5.1mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC146-4Pin_6.7x1.5mm +SMD Crystal Seiko Epson MC-146 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, 6.7x1.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC146-4Pin_6.7x1.5mm_HandSoldering +SMD Crystal Seiko Epson MC-146 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, hand-soldering, 6.7x1.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC156-4Pin_7.1x2.5mm +SMD Crystal Seiko Epson MC-156 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, 7.1x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC156-4Pin_7.1x2.5mm_HandSoldering +SMD Crystal Seiko Epson MC-156 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-156_en.pdf, hand-soldering, 7.1x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC306-4Pin_8.0x3.2mm +SMD Crystal Seiko Epson MC-306 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, 8.0x3.2mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC306-4Pin_8.0x3.2mm_HandSoldering +SMD Crystal Seiko Epson MC-306 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, hand-soldering, 8.0x3.2mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC405-2Pin_9.6x4.1mm +SMD Crystal Seiko Epson MC-405 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, 9.6x4.1mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MC405-2Pin_9.6x4.1mm_HandSoldering +SMD Crystal Seiko Epson MC-405 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, hand-soldering, 9.6x4.1mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_SeikoEpson_MC406-4Pin_9.6x4.1mm +SMD Crystal Seiko Epson MC-406 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, 9.6x4.1mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_MC406-4Pin_9.6x4.1mm_HandSoldering +SMD Crystal Seiko Epson MC-406 https://support.epson.biz/td/api/doc_check.php?dl=brief_MC-306_en.pdf, hand-soldering, 9.6x4.1mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_TSX3225-4Pin_3.2x2.5mm +crystal Epson Toyocom TSX-3225 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_SeikoEpson_TSX3225-4Pin_3.2x2.5mm_HandSoldering +crystal Epson Toyocom TSX-3225 series https://support.epson.biz/td/api/doc_check.php?dl=brief_fa-238v_en.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_TXC_7A-2Pin_5x3.2mm +SMD Crystal TXC 7A http://txccrystal.com/images/pdf/7a.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_TXC_7M-4Pin_3.2x2.5mm +SMD Crystal TXC 7M http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, 3.2x2.5mm^2 package +SMD SMT crystal +0 +4 +4 +Crystal +Crystal_SMD_TXC_7M-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal TXC 7M http://www.txccrystal.com/images/pdf/7m-accuracy.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal hand-soldering +0 +4 +4 +Crystal +Crystal_SMD_TXC_9HT11-2Pin_2.0x1.2mm +SMD Crystal TXC 9HT11 http://txccrystal.com/images/pdf/9ht11.pdf, 2.0x1.2mm^2 package +SMD SMT crystal +0 +2 +2 +Crystal +Crystal_SMD_TXC_9HT11-2Pin_2.0x1.2mm_HandSoldering +SMD Crystal TXC 9HT11 http://txccrystal.com/images/pdf/9ht11.pdf, hand-soldering, 2.0x1.2mm^2 package +SMD SMT crystal hand-soldering +0 +2 +2 +Crystal +Crystal_SMD_TXC_AX_8045-2Pin_8.0x4.5mm +http://www.txccrystal.com/images/pdf/ax-automotive.pdf +SMD SMT crystal +0 +2 +2 +Crystal +Resonator-2Pin_W6.0mm_H3.0mm +Ceramic Resomator/Filter 6.0x3.0mm^2, length*width=6.0x3.0mm^2 package, package length=6.0mm, package width=3.0mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-2Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter 7.0x2.5mm^2, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-2Pin_W8.0mm_H3.5mm +Ceramic Resomator/Filter 8.0x3.5mm^2, length*width=8.0x3.5mm^2 package, package length=8.0mm, package width=3.5mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-2Pin_W10.0mm_H5.0mm +Ceramic Resomator/Filter 10.0x5.0 RedFrequency MG/MT/MX series, http://www.red-frequency.com/download/datenblatt/redfrequency-datenblatt-ir-zta.pdf, length*width=10.0x5.0mm^2 package, package length=10.0mm, package width=5.0mm, 2 pins +THT ceramic resonator filter +0 +2 +2 +Crystal +Resonator-3Pin_W6.0mm_H3.0mm +Ceramic Resomator/Filter 6.0x3.0mm^2, length*width=6.0x3.0mm^2 package, package length=6.0mm, package width=3.0mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator-3Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter 7.0x2.5mm^2, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator-3Pin_W8.0mm_H3.5mm +Ceramic Resomator/Filter 8.0x3.5mm^2, length*width=8.0x3.5mm^2 package, package length=8.0mm, package width=3.5mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator-3Pin_W10.0mm_H5.0mm +Ceramic Resomator/Filter 10.0x5.0mm^2 RedFrequency MG/MT/MX series, http://www.red-frequency.com/download/datenblatt/redfrequency-datenblatt-ir-zta.pdf, length*width=10.0x5.0mm^2 package, package length=10.0mm, package width=5.0mm, 3 pins +THT ceramic resonator filter +0 +3 +3 +Crystal +Resonator_SMD-3Pin_7.2x3.0mm +SMD Resomator/Filter 7.2x3.0mm, Murata CSTCC8M00G53-R0; 8MHz resonator, SMD, Farnell (Element 14) #1170435, http://www.farnell.com/datasheets/19296.pdf?_ga=1.247244932.122297557.1475167906, 7.2x3.0mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD-3Pin_7.2x3.0mm_HandSoldering +SMD Resomator/Filter 7.2x3.0mm, Murata CSTCC8M00G53-R0; 8MHz resonator, SMD, Farnell (Element 14) #1170435, http://www.farnell.com/datasheets/19296.pdf?_ga=1.247244932.122297557.1475167906, hand-soldering, 7.2x3.0mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_SMD_muRata_CDSCB-2Pin_4.5x2.0mm +SMD Resomator/Filter Murata CDSCB, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 4.5x2.0mm^2 package +SMD SMT ceramic resonator filter filter +0 +2 +2 +Crystal +Resonator_SMD_muRata_CDSCB-2Pin_4.5x2.0mm_HandSoldering +SMD Resomator/Filter Murata CDSCB, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 4.5x2.0mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +2 +2 +Crystal +Resonator_SMD_muRata_CSTxExxV-3Pin_3.0x1.1mm +SMD Resomator/Filter Murata CSTCE, https://www.murata.com/en-eu/products/productdata/8801162264606/SPEC-CSTNE16M0VH3C000R0.pdf +SMD SMT ceramic resonator filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_CSTxExxV-3Pin_3.0x1.1mm_HandSoldering +SMD Resomator/Filter Murata CSTCE, https://www.murata.com/en-eu/products/productdata/8801162264606/SPEC-CSTNE16M0VH3C000R0.pdf +SMD SMT ceramic resonator filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFECV-3Pin_6.9x2.9mm +SMD Resomator/Filter Murata SFECV, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 6.9x2.9mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFECV-3Pin_6.9x2.9mm_HandSoldering +SMD Resomator/Filter Murata SFECV, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 6.9x2.9mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFSKA-3Pin_7.9x3.8mm +SMD Resomator/Filter Murata SFSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_SFSKA-3Pin_7.9x3.8mm_HandSoldering +SMD Resomator/Filter Murata SFSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_SMD_muRata_TPSKA-3Pin_7.9x3.8mm +SMD Resomator/Filter Murata TPSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter +0 +3 +3 +Crystal +Resonator_SMD_muRata_TPSKA-3Pin_7.9x3.8mm_HandSoldering +SMD Resomator/Filter Murata TPSKA, http://cdn-reichelt.de/documents/datenblatt/B400/SFECV-107.pdf, hand-soldering, 7.9x3.8mm^2 package +SMD SMT ceramic resonator filter filter hand-soldering +0 +3 +3 +Crystal +Resonator_muRata_CSTLSxxxG-3Pin_W8.0mm_H3.0mm +Ceramic Resomator/Filter Murata CSTLSxxxG, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/timingdevice/ceralock/p17e.ashx, length*width=8.0x3.0mm^2 package, package length=8.0mm, package width=3.0mm, 3 pins +THT ceramic resonator filter CSTLSxxxG +0 +3 +3 +Crystal +Resonator_muRata_CSTLSxxxX-3Pin_W5.5mm_H3.0mm +Ceramic Resomator/Filter Murata CSTLSxxxX, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/timingdevice/ceralock/p17e.ashx, length*width=5.5x3.0mm^2 package, package length=5.5mm, package width=3.0mm, 3 pins +THT ceramic resonator filter CSTLSxxxX +0 +3 +3 +Crystal +Resonator_muRata_DSN6-3Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter Murata DSN6, http://cdn-reichelt.de/documents/datenblatt/B400/DSN6NC51H.pdf, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 3 pins +THT ceramic resonator filter DSN6 +0 +3 +3 +Crystal +Resonator_muRata_DSS6-3Pin_W7.0mm_H2.5mm +Ceramic Resomator/Filter Murata DSS6, http://cdn-reichelt.de/documents/datenblatt/B400/DSN6NC51H.pdf, length*width=7.0x2.5mm^2 package, package length=7.0mm, package width=2.5mm, 3 pins +THT ceramic resonator filter DSS6 +0 +3 +3 +Diode_SMD +D_0201_0603Metric +Diode SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +diode +0 +4 +2 +Diode_SMD +D_0201_0603Metric_Castellated +Diode SMD 0201 (0603 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +diode castellated +0 +4 +2 +Diode_SMD +D_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Diode SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +diode handsolder +0 +4 +2 +Diode_SMD +D_0402_1005Metric +Diode SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_0402_1005Metric_Castellated +Diode SMD 0402 (1005 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_0402_1005Metric_Pad0.77x0.64mm_HandSolder +Diode SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_0603_1608Metric +Diode SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_0603_1608Metric_Castellated +Diode SMD 0603 (1608 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_0603_1608Metric_Pad1.05x0.95mm_HandSolder +Diode SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_0805_2012Metric +Diode SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_0805_2012Metric_Castellated +Diode SMD 0805 (2012 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_0805_2012Metric_Pad1.15x1.40mm_HandSolder +Diode SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_01005_0402Metric +Diode SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +diode +0 +4 +2 +Diode_SMD +D_01005_0402Metric_Castellated +Diode SMD 01005 (0402 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +diode castellated +0 +4 +2 +Diode_SMD +D_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Diode SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +diode handsolder +0 +4 +2 +Diode_SMD +D_1206_3216Metric +Diode SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_1206_3216Metric_Castellated +Diode SMD 1206 (3216 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_1206_3216Metric_Pad1.42x1.75mm_HandSolder +Diode SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_1210_3225Metric +Diode SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_1210_3225Metric_Castellated +Diode SMD 1210 (3225 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_1210_3225Metric_Pad1.42x2.65mm_HandSolder +Diode SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_1812_4532Metric +Diode SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_1812_4532Metric_Castellated +Diode SMD 1812 (4532 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Diode SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2010_5025Metric +Diode SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2010_5025Metric_Castellated +Diode SMD 2010 (5025 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2010_5025Metric_Pad1.52x2.65mm_HandSolder +Diode SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2114_3652Metric +Diode SMD 2114 (3652 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2114_3652Metric_Castellated +Diode SMD 2114 (3652 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2114_3652Metric_Pad1.85x3.75mm_HandSolder +Diode SMD 2114 (3652 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2512_6332Metric +Diode SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2512_6332Metric_Castellated +Diode SMD 2512 (6332 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2512_6332Metric_Pad1.52x3.35mm_HandSolder +Diode SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_2816_7142Metric +Diode SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_2816_7142Metric_Castellated +Diode SMD 2816 (7142 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Diode SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_3220_8050Metric +Diode SMD 3220 (8050 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode +0 +2 +2 +Diode_SMD +D_3220_8050Metric_Castellated +Diode SMD 3220 (8050 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode castellated +0 +2 +2 +Diode_SMD +D_3220_8050Metric_Pad2.65x5.15mm_HandSolder +Diode SMD 3220 (8050 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator +diode handsolder +0 +2 +2 +Diode_SMD +D_MELF +Diode, MELF,, +Diode MELF +0 +2 +2 +Diode_SMD +D_MELF-RM10_Universal_Handsoldering +Diode, Universal, MELF, RM10, Handsoldering, SMD, Thruhole, +Diode Universal MELF RM10 Handsoldering SMD Thruhole +0 +2 +2 +Diode_SMD +D_MELF_Handsoldering +Diode MELF Handsoldering +Diode MELF Handsoldering +0 +2 +2 +Diode_SMD +D_MicroMELF +Diode, MicroMELF, Reflow Soldering, http://www.vishay.com/docs/85597/bzm55.pdf +MicroMELF Diode +0 +2 +2 +Diode_SMD +D_MicroMELF_Handsoldering +Diode, MicroMELF, Hand Soldering, http://www.vishay.com/docs/85597/bzm55.pdf +MicroMELF Diode +0 +2 +2 +Diode_SMD +D_MiniMELF +Diode Mini-MELF (SOD-80) +Diode Mini-MELF (SOD-80) +0 +2 +2 +Diode_SMD +D_MiniMELF_Handsoldering +Diode Mini-MELF (SOD-80) Handsoldering +Diode Mini-MELF (SOD-80) Handsoldering +0 +2 +2 +Diode_SMD +D_PowerDI-5 +PowerDI,Diode,Vishay,https://www.diodes.com/assets/Package-Files/PowerDI5.pdf +PowerDI diode vishay +0 +3 +2 +Diode_SMD +D_PowerDI-123 +http://www.diodes.com/_files/datasheets/ds30497.pdf +PowerDI diode vishay +0 +2 +2 +Diode_SMD +D_Powermite2_AK +Microsemi Powermite 2 SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5341) +PowerMite2 +0 +2 +2 +Diode_SMD +D_Powermite2_KA +Microsemi Powermite 2 SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5341) +PowerMite2 +0 +2 +2 +Diode_SMD +D_Powermite3 +Microsemi Powermite 3 SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5340) +PowerMite3 +0 +3 +3 +Diode_SMD +D_Powermite_AK +Microsemi Powermite SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5339, https://www.onsemi.com/pub/Collateral/457-04.PDF) +Powermite +0 +2 +2 +Diode_SMD +D_Powermite_KA +Microsemi Powermite SMD power package (https://www.microsemi.com/packaging-information/partpackage/details?pid=5339, https://www.onsemi.com/pub/Collateral/457-04.PDF) +Powermite +0 +2 +2 +Diode_SMD +D_QFN_3.3x3.3mm_P0.65mm +QFN, diode, 3.3x3.3x1mm (https://www.wolfspeed.com/media/downloads/846/C3D1P7060Q.pdf) +diode qfn 3.3 +0 +3 +2 +Diode_SMD +D_SC-80 +JEITA SC-80 +SC-80 +0 +2 +2 +Diode_SMD +D_SC-80_HandSoldering +JEITA SC-80 +SC-80 +0 +2 +2 +Diode_SMD +D_SMA +Diode SMA (DO-214AC) +Diode SMA (DO-214AC) +0 +2 +2 +Diode_SMD +D_SMA-SMB_Universal_Handsoldering +Diode, Universal, SMA (DO-214AC) or SMB (DO-214AA), Handsoldering, +Diode Universal SMA (DO-214AC) SMB (DO-214AA) Handsoldering +0 +2 +2 +Diode_SMD +D_SMA_Handsoldering +Diode SMA (DO-214AC) Handsoldering +Diode SMA (DO-214AC) Handsoldering +0 +2 +2 +Diode_SMD +D_SMB +Diode SMB (DO-214AA) +Diode SMB (DO-214AA) +0 +2 +2 +Diode_SMD +D_SMB-SMC_Universal_Handsoldering +Diode, Universal, SMB(DO-214AA) or SMC (DO-214AB), Handsoldering, +Diode Universal SMB(DO-214AA) SMC (DO-214AB) Handsoldering +0 +2 +2 +Diode_SMD +D_SMB_Handsoldering +Diode SMB (DO-214AA) Handsoldering +Diode SMB (DO-214AA) Handsoldering +0 +2 +2 +Diode_SMD +D_SMB_Modified +Diode SMB (DO-214AA) Modified (http://www.littelfuse.com/~/media/electronics/datasheets/sidactors/littelfuse_sidactor_battrax_positive_negative_modified_do_214_datasheet.pdf.pdf) +Diode SMB (DO-214AA) +0 +3 +3 +Diode_SMD +D_SMC +Diode SMC (DO-214AB) +Diode SMC (DO-214AB) +0 +2 +2 +Diode_SMD +D_SMC-RM10_Universal_Handsoldering +Diode, Universal, SMC (DO-214AB), RM10, Handsoldering, SMD, Thruhole +Diode Universal SMC (DO-214AB) RM10 Handsoldering SMD Thruhole +0 +2 +2 +Diode_SMD +D_SMC_Handsoldering +Diode SMC (DO-214AB) Handsoldering +Diode SMC (DO-214AB) Handsoldering +0 +2 +2 +Diode_SMD +D_SMF +Diode SMF (DO-219AB), http://www.vishay.com/docs/95572/smf_do-219ab.pdf +Diode SMF (DO-214AB) +0 +2 +2 +Diode_SMD +D_SOD-110 +SOD-110 +SOD-110 +0 +2 +2 +Diode_SMD +D_SOD-123 +SOD-123 +SOD-123 +0 +2 +2 +Diode_SMD +D_SOD-123F +D_SOD-123F +D_SOD-123F +0 +2 +2 +Diode_SMD +D_SOD-128 +D_SOD-128 (CFP5 SlimSMAW), https://assets.nexperia.com/documents/outline-drawing/SOD128.pdf +D_SOD-128 +0 +2 +2 +Diode_SMD +D_SOD-323 +SOD-323 +SOD-323 +0 +2 +2 +Diode_SMD +D_SOD-323F +SOD-323F http://www.nxp.com/documents/outline_drawing/SOD323F.pdf +SOD-323F +0 +2 +2 +Diode_SMD +D_SOD-323_HandSoldering +SOD-323 +SOD-323 +0 +2 +2 +Diode_SMD +D_SOD-523 +http://www.diodes.com/datasheets/ap02001.pdf p.144 +Diode SOD523 +0 +2 +2 +Diode_SMD +D_SOD-923 +https://www.onsemi.com/pub/Collateral/ESD9B-D.PDF#page=4 +Diode SOD923 +0 +2 +2 +Diode_SMD +D_SOT-23_ANK +SOT-23, Single Diode +SOT-23 +0 +3 +2 +Diode_SMD +D_SOT-23_NKA +SOT-23, Single Diode +SOT-23 +0 +3 +2 +Diode_SMD +D_TUMD2 +ROHM - TUMD2 +TUMD2 +0 +2 +2 +Diode_SMD +Diode_Bridge_Bourns_CD-DF4xxS +8.1x10.5mm, 4A, single phase bridge rectifier, https://www.bourns.com/docs/Product-Datasheets/CD-DF4xxSL.pdf +Surface Mount Bridge Rectifier Diode +0 +4 +4 +Diode_SMD +Diode_Bridge_Diotec_ABS +SMD diode bridge ABS (Diotec), see https://diotec.com/tl_files/diotec/files/pdf/datasheets/abs2.pdf +ABS MBLS +0 +4 +4 +Diode_SMD +Diode_Bridge_Diotec_MicroDil_3.0x3.0x1.8mm +SMD package Diotec Diotec MicroDil, body 3.0x3.0x1.8mm (e.g. diode bridge), see https://diotec.com/tl_files/diotec/files/pdf/datasheets/mys40.pdf +Diotec MicroDil diode bridge +0 +4 +4 +Diode_SMD +Diode_Bridge_Diotec_SO-DIL-Slim +SMD diode bridge Diotec SO-DIL Slim, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/b40fs.pdf +DFS SO-DIL Slim +0 +4 +4 +Diode_SMD +Diode_Bridge_Vishay_DFS +SMD diode bridge DFS, see http://www.vishay.com/docs/88854/padlayouts.pdf +DFS +0 +4 +4 +Diode_SMD +Diode_Bridge_Vishay_DFSFlat +SMD diode bridge Low Profile DFS "Flat", see http://www.vishay.com/docs/88874/dfl15005.pdf +DFS +0 +4 +4 +Diode_SMD +Diode_Bridge_Vishay_MBLS +SMD diode bridge MBLS, see http://www.vishay.com/docs/89959/mbl104s.pdf http://www.vishay.com/docs/88854/padlayouts.pdf +DFS +0 +4 +4 +Diode_SMD +Littelfuse_PolyZen-LS +http://m.littelfuse.com/~/media/electronics/datasheets/polyzen_devices/littelfuse_polyzen_standard_polyzen_catalog_datasheet.pdf.pdf +Diode Polymer Protected Zener Diode Littelfuse LS +0 +3 +3 +Diode_THT +D_5KPW_P7.62mm_Vertical_AnodeUp +Diode, 5KPW series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9*8mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KPW series Axial Vertical pin pitch 7.62mm length 9mm diameter 8mm +0 +2 +2 +Diode_THT +D_5KPW_P7.62mm_Vertical_KathodeUp +Diode, 5KPW series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9*8mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KPW series Axial Vertical pin pitch 7.62mm length 9mm diameter 8mm +0 +2 +2 +Diode_THT +D_5KPW_P12.70mm_Horizontal +Diode, 5KPW series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9*8mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KPW series Axial Horizontal pin pitch 12.7mm length 9mm diameter 8mm +0 +2 +2 +Diode_THT +D_5KP_P7.62mm_Vertical_AnodeUp +Diode, 5KP series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Vertical pin pitch 7.62mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5KP_P7.62mm_Vertical_KathodeUp +Diode, 5KP series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Vertical pin pitch 7.62mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5KP_P10.16mm_Horizontal +Diode, 5KP series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Horizontal pin pitch 10.16mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5KP_P12.70mm_Horizontal +Diode, 5KP series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=7.62*9.53mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5KP series Axial Horizontal pin pitch 12.7mm length 7.62mm diameter 9.53mm +0 +2 +2 +Diode_THT +D_5W_P5.08mm_Vertical_AnodeUp +Diode, 5W series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Vertical pin pitch 5.08mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_5W_P5.08mm_Vertical_KathodeUp +Diode, 5W series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Vertical pin pitch 5.08mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_5W_P10.16mm_Horizontal +Diode, 5W series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Horizontal pin pitch 10.16mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_5W_P12.70mm_Horizontal +Diode, 5W series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=8.9*3.7mm^2, , http://www.diodes.com/_files/packages/8686949.gif +Diode 5W series Axial Horizontal pin pitch 12.7mm length 8.9mm diameter 3.7mm +0 +2 +2 +Diode_THT +D_A-405_P2.54mm_Vertical_AnodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P2.54mm_Vertical_KathodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P5.08mm_Vertical_AnodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P5.08mm_Vertical_KathodeUp +Diode, A-405 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P7.62mm_Horizontal +Diode, A-405 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Horizontal pin pitch 7.62mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P10.16mm_Horizontal +Diode, A-405 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Horizontal pin pitch 10.16mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_A-405_P12.70mm_Horizontal +Diode, A-405 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/A-405.pdf +Diode A-405 series Axial Horizontal pin pitch 12.7mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-15_P2.54mm_Vertical_AnodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 2.54mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P2.54mm_Vertical_KathodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 2.54mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P3.81mm_Vertical_AnodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 3.81mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P3.81mm_Vertical_KathodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 3.81mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P5.08mm_Vertical_AnodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 5.08mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P5.08mm_Vertical_KathodeUp +Diode, DO-15 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Vertical pin pitch 5.08mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P10.16mm_Horizontal +Diode, DO-15 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Horizontal pin pitch 10.16mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P12.70mm_Horizontal +Diode, DO-15 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Horizontal pin pitch 12.7mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-15_P15.24mm_Horizontal +Diode, DO-15 series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=7.6*3.6mm^2, , http://www.diodes.com/_files/packages/DO-15.pdf +Diode DO-15 series Axial Horizontal pin pitch 15.24mm length 7.6mm diameter 3.6mm +0 +2 +2 +Diode_THT +D_DO-27_P5.08mm_Vertical_AnodeUp +Diode, DO-27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Vertical pin pitch 5.08mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-27_P5.08mm_Vertical_KathodeUp +Diode, DO-27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Vertical pin pitch 5.08mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-27_P12.70mm_Horizontal +Diode, DO-27 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Horizontal pin pitch 12.7mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-27_P15.24mm_Horizontal +Diode, DO-27 series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.52*5.33mm^2, , http://www.slottechforum.com/slotinfo/Techstuff/CD2%20Diodes%20and%20Transistors/Cases/Diode%20DO-27.jpg +Diode DO-27 series Axial Horizontal pin pitch 15.24mm length 9.52mm diameter 5.33mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P2.54mm_Vertical_AnodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 2.54mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P2.54mm_Vertical_KathodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 2.54mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P5.08mm_Vertical_AnodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 5.08mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P5.08mm_Vertical_KathodeUp +Diode, DO-34_SOD68 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Vertical pin pitch 5.08mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P7.62mm_Horizontal +Diode, DO-34_SOD68 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Horizontal pin pitch 7.62mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P10.16mm_Horizontal +Diode, DO-34_SOD68 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Horizontal pin pitch 10.16mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-34_SOD68_P12.70mm_Horizontal +Diode, DO-34_SOD68 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=3.04*1.6mm^2, , https://www.nxp.com/docs/en/data-sheet/KTY83_SER.pdf +Diode DO-34_SOD68 series Axial Horizontal pin pitch 12.7mm length 3.04mm diameter 1.6mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P2.54mm_Vertical_AnodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 2.54mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P2.54mm_Vertical_KathodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 2.54mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P3.81mm_Vertical_AnodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 3.81mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P3.81mm_Vertical_KathodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 3.81mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P5.08mm_Vertical_AnodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 5.08mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P5.08mm_Vertical_KathodeUp +Diode, DO-35_SOD27 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Vertical pin pitch 5.08mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P7.62mm_Horizontal +Diode, DO-35_SOD27 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Horizontal pin pitch 7.62mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P10.16mm_Horizontal +Diode, DO-35_SOD27 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Horizontal pin pitch 10.16mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-35_SOD27_P12.70mm_Horizontal +Diode, DO-35_SOD27 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=4*2mm^2, , http://www.diodes.com/_files/packages/DO-35.pdf +Diode DO-35_SOD27 series Axial Horizontal pin pitch 12.7mm length 4mm diameter 2mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P2.54mm_Vertical_AnodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P2.54mm_Vertical_KathodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 2.54mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P3.81mm_Vertical_AnodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=5.2*2.7mm^2, , https://www.diodes.com/assets/Package-Files/DO-41-Plastic.pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 3.81mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P3.81mm_Vertical_KathodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=5.2*2.7mm^2, , https://www.diodes.com/assets/Package-Files/DO-41-Plastic.pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 3.81mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P5.08mm_Vertical_AnodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P5.08mm_Vertical_KathodeUp +Diode, DO-41_SOD81 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Vertical pin pitch 5.08mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P7.62mm_Horizontal +Diode, DO-41_SOD81 series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Horizontal pin pitch 7.62mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P10.16mm_Horizontal +Diode, DO-41_SOD81 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Horizontal pin pitch 10.16mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-41_SOD81_P12.70mm_Horizontal +Diode, DO-41_SOD81 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=5.2*2.7mm^2, , http://www.diodes.com/_files/packages/DO-41%20(Plastic).pdf +Diode DO-41_SOD81 series Axial Horizontal pin pitch 12.7mm length 5.2mm diameter 2.7mm +0 +2 +2 +Diode_THT +D_DO-201AD_P3.81mm_Vertical_AnodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 3.81mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P3.81mm_Vertical_KathodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 3.81mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P5.08mm_Vertical_AnodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 5.08mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P5.08mm_Vertical_KathodeUp +Diode, DO-201AD series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Vertical pin pitch 5.08mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P12.70mm_Horizontal +Diode, DO-201AD series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Horizontal pin pitch 12.7mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AD_P15.24mm_Horizontal +Diode, DO-201AD series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.5*5.2mm^2, , http://www.diodes.com/_files/packages/DO-201AD.pdf +Diode DO-201AD series Axial Horizontal pin pitch 15.24mm length 9.5mm diameter 5.2mm +0 +2 +2 +Diode_THT +D_DO-201AE_P3.81mm_Vertical_AnodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 3.81mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P3.81mm_Vertical_KathodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 3.81mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P5.08mm_Vertical_AnodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 5.08mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P5.08mm_Vertical_KathodeUp +Diode, DO-201AE series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Vertical pin pitch 5.08mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P12.70mm_Horizontal +Diode, DO-201AE series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Horizontal pin pitch 12.7mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201AE_P15.24mm_Horizontal +Diode, DO-201AE series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9*5.3mm^2, , http://www.farnell.com/datasheets/529758.pdf +Diode DO-201AE series Axial Horizontal pin pitch 15.24mm length 9mm diameter 5.3mm +0 +2 +2 +Diode_THT +D_DO-201_P3.81mm_Vertical_AnodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 3.81mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P3.81mm_Vertical_KathodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=3.81mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 3.81mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P5.08mm_Vertical_AnodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 5.08mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P5.08mm_Vertical_KathodeUp +Diode, DO-201 series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Vertical pin pitch 5.08mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P12.70mm_Horizontal +Diode, DO-201 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Horizontal pin pitch 12.7mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-201_P15.24mm_Horizontal +Diode, DO-201 series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.53*5.21mm^2, , http://www.diodes.com/_files/packages/DO-201.pdf +Diode DO-201 series Axial Horizontal pin pitch 15.24mm length 9.53mm diameter 5.21mm +0 +2 +2 +Diode_THT +D_DO-247_Horizontal_TabDown +Diode, DO-247 series, Horizontal, TabDown, P 10.9mm +diode rectifier +0 +2 +2 +Diode_THT +D_DO-247_Horizontal_TabUp +Diode, DO-247 series, Horizontal, TabUp, P 10.9mm +diode rectifier +0 +2 +2 +Diode_THT +D_DO-247_Vertical +Diode, DO-247 series, Vertical, P 10.9mm +diode rectifier +0 +2 +2 +Diode_THT +D_P600_R-6_P7.62mm_Vertical_AnodeUp +Diode, P600_R-6 series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Vertical pin pitch 7.62mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_P600_R-6_P7.62mm_Vertical_KathodeUp +Diode, P600_R-6 series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Vertical pin pitch 7.62mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_P600_R-6_P12.70mm_Horizontal +Diode, P600_R-6 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Horizontal pin pitch 12.7mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_P600_R-6_P20.00mm_Horizontal +Diode, P600_R-6 series, Axial, Horizontal, pin pitch=20mm, , length*diameter=9.1*9.1mm^2, , http://www.vishay.com/docs/88692/p600a.pdf, http://www.diodes.com/_files/packages/R-6.pdf +Diode P600_R-6 series Axial Horizontal pin pitch 20mm length 9.1mm diameter 9.1mm +0 +2 +2 +Diode_THT +D_T-1_P2.54mm_Vertical_AnodeUp +Diode, T-1 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Vertical pin pitch 2.54mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P2.54mm_Vertical_KathodeUp +Diode, T-1 series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Vertical pin pitch 2.54mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P5.08mm_Horizontal +Diode, T-1 series, Axial, Horizontal, pin pitch=5.08mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Horizontal pin pitch 5.08mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P10.16mm_Horizontal +Diode, T-1 series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Horizontal pin pitch 10.16mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +D_T-1_P12.70mm_Horizontal +Diode, T-1 series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=3.2*2.6mm^2, , http://www.diodes.com/_files/packages/T-1.pdf +Diode T-1 series Axial Horizontal pin pitch 12.7mm length 3.2mm diameter 2.6mm +0 +2 +2 +Diode_THT +Diode_Bridge_15.1x15.1x6.3mm_P10.9mm +Single phase bridge rectifier case 15.1x15.1mm, pitch 10.9mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/pb1000.pdf +Diode Bridge PB10xxS +0 +4 +4 +Diode_THT +Diode_Bridge_15.2x15.2x6.3mm_P10.9mm +Single phase bridge rectifier case 15.2x15.2mm, pitch 10.9mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/kbpc600.pdf +Diode Bridge KBPC6xx +0 +4 +4 +Diode_THT +Diode_Bridge_15.7x15.7x6.3mm_P10.8mm +Single phase bridge rectifier case 15.7x15.7 +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_16.7x16.7x6.3mm_P10.8mm +Single phase bridge rectifier case 16.7x16.7 +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_19.0x3.5x10.0mm_P5.0mm +Vishay GBU rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88606/g3sba20.pdf +Vishay GBU rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_19.0x19.0x6.8mm_P12.7mm +Single phase bridge rectifier case 19x19mm, pitch 12.7mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/pb1000.pdf +Diode Bridge PB10xx +0 +4 +4 +Diode_THT +Diode_Bridge_28.6x28.6x7.3mm_P18.0mm_P11.6mm +Single phase bridge rectifier case 28.6x28.6mm, pitch 18.0mm & 11.6mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/kbpc1500fw.pdf +Diode Bridge KBPCxxxxWP +0 +4 +4 +Diode_THT +Diode_Bridge_32.0x5.6x17.0mm_P10.0mm_P7.5mm +Diotec 32x5.6x17mm rectifier package, 7.5mm/10mm pitch, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/b40c3700.pdf +Diotec rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_DIP-4_W5.08mm_P2.54mm +4-lead dip package for diode bridges, row spacing 5.08mm, pin-spacing 2.54mm, see http://www.vishay.com/docs/88898/b2m.pdf +DIL DIP PDIP 5.08mm 2.54 +0 +4 +4 +Diode_THT +Diode_Bridge_DIP-4_W7.62mm_P5.08mm +4-lead dip package for diode bridges, row spacing 7.62 mm (300 mils), see http://cdn-reichelt.de/documents/datenblatt/A400/HDBL101G_20SERIES-TSC.pdf +DIL DIP PDIP 5.08mm 7.62mm 300mil +0 +4 +4 +Diode_THT +Diode_Bridge_IXYS_GUFP +Three phase, Bridge, Rectifier +diode module +0 +5 +5 +Diode_THT +Diode_Bridge_Round_D8.9mm +4-lead round diode bridge package, diameter 8.9mm, pin pitch 5.08mm, see http://cdn-reichelt.de/documents/datenblatt/A400/W005M-W10M_SEP.PDF +diode bridge 8.9mm 8.85mm WOB pitch 5.08mm +0 +4 +4 +Diode_THT +Diode_Bridge_Round_D9.0mm +4-lead round diode bridge package, diameter 9.0mm, pin pitch 5.0mm, see https://diotec.com/tl_files/diotec/files/pdf/datasheets/b40r.pdf +diode bridge 9.0mm 8.85mm WOB pitch 5.0mm +0 +4 +4 +Diode_THT +Diode_Bridge_Round_D9.8mm +4-lead round diode bridge package, diameter 9.8mm, pin pitch 5.08mm, see http://www.vishay.com/docs/88769/woo5g.pdf +diode bridge 9.8mm WOG pitch 5.08mm +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_GBL +Vishay GBL rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88609/gbl005.pdf +Vishay GBL rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_GBU +Vishay GBU rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88606/g3sba20.pdf +Vishay GBU rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBL +Vishay KBL rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88655/kbl005.pdf +Vishay KBL rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBPC1 +Single phase bridge rectifier case KBPC1, see http://www.vishay.com/docs/93585/vs-kbpc1series.pdf +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBPC6 +Single phase bridge rectifier case KBPC6, see http://www.vishay.com/docs/93585/vs-kbpc1series.pdf +Diode Bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBPM +Vishay KBM rectifier package, 3.95mm pitch (http://www.farnell.com/datasheets/2238158.pdf, http://www.cdil.com/s/kbp2005_.pdf) +Vishay KBM rectifier diode bridge +0 +4 +4 +Diode_THT +Diode_Bridge_Vishay_KBU +Vishay KBU rectifier package, 5.08mm pitch, see http://www.vishay.com/docs/88656/kbu4.pdf +Vishay KBU rectifier diode bridge +0 +4 +4 +Display +AG12864E +STN/FSTN LCD 128x64 dot https://www.digchip.com/datasheets/parts/datasheet/1121/AG-12864E-pdf.php +AG12864E Graphics Display 128x64 Ampire +0 +24 +20 +Display +Adafruit_SSD1306 +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI https://learn.adafruit.com/monochrome-oled-breakouts/downloads +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI +0 +8 +8 +Display +Adafruit_SSD1306_No_Mounting_Holes +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI https://learn.adafruit.com/monochrome-oled-breakouts/downloads +Adafruit SSD1306 OLED 1.3 inch 128x64 I2C & SPI +0 +8 +8 +Display +CR2013-MI2120 +CR2013-MI2120 ILI9341 LCD Breakout http://pan.baidu.com/s/11Y990 +CR2013-MI2120 ILI9341 LCD Breakout +0 +18 +14 +Display +EA-eDIP128B-XXX +LCD-graphical display with LED backlight 128x64 RS-232 I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip128-6e.pdf +LCD-graphical display with LED backlight 128x64 RS-232 I2C or SPI +0 +32 +32 +Display +EA_DOGS104X-A +LCD 4x10 character 3.3V VDD I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/doma/dogs104e.pdf +LCD 4x10 character 3.3V VDD I2C or SPI +0 +14 +14 +Display +EA_DOGXL160-7 +Grapchical,Display,LCD,160x104 http://www.lcd-module.com/eng/pdf/grafik/dogxl160-7e.pdf +EA_DOGXL160-7 +0 +22 +22 +Display +EA_DOGXL160-7_Backlight +Grapchical,Display,LCD,160x104 http://www.lcd-module.com/eng/pdf/grafik/dogxl160-7e.pdf +EA_DOGXL160-7_Backlight +0 +22 +22 +Display +EA_T123X-I2C +http://www.lcd-module.de/pdf/doma/t123-i2c.pdf +3 Line 12 character wide alpha numeric LCD +0 +6 +6 +Display +EA_eDIP160-XXX +LCD-graphical display with LED backlight 160x104 RS-232 I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip160-7e.pdf +LCD-graphical display with LED backlight 160x104 RS-232 I2C or SPI +0 +40 +40 +Display +EA_eDIP240-XXX +LCD graphical display LED backlight 240x128 http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip240-7e.pdf +LCD graphical display LED backlight 240x128 +0 +40 +40 +Display +EA_eDIP320X-XXX +LCD display 320x340 RS-232 I2C or SPI http://www.lcd-module.com/fileadmin/eng/pdf/grafik/edip320-8e.pdf +LCD display 320x340 RS-232 I2C or SPI +0 +48 +48 +Display +EA_eDIPTFT32-XXX +TFT-graphic display 320x240 16 bit colour with led backlight http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft32-ae.pdf +TFT-graphic display 320x240 16 bit colour with led backlight +0 +40 +40 +Display +EA_eDIPTFT43-ATC +http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft43-ae.pdf +TFT graphical display 480x272 16-bit colour with LED backlight +0 +40 +40 +Display +EA_eDIPTFT43-XXX +TFT graphical display 480x272 16-bit colour with LED backlight http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft43-ae.pdf +TFT graphical display 480x272 16-bit colour with LED backlight +0 +40 +40 +Display +EA_eDIPTFT57-XXX +http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft57-ae.pdf +TFT-graphic display 640x480 16 bit colour +0 +48 +48 +Display +EA_eDIPTFT70-ATC +TFT-graphical display 800x480 16-bit colours with capacitive touch panel http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft70-ae.pdf +TFT-graphical display 800x480 16-bit colours with capacitive touch panel +0 +48 +48 +Display +EA_eDIPTFT70-XXX +TFT-graphical display 800x480 16-bit colours http://www.lcd-module.com/fileadmin/eng/pdf/grafik/ediptft70-ae.pdf +TFT-graphical display 800x480 16-bit colours and touch display +0 +48 +48 +Display +HDSM-441B_HDSM-443B +2 Digit 7 segemnt blue LED, right hand decimal, https://docs.broadcom.com/docs/AV02-1589EN +2 Digit 7 segment blue LED +0 +10 +10 +Display +HDSM-541B_HDSM-543B +2 digit 7 segement blue LED with right hand decimal, https://docs.broadcom.com/docs/AV02-1588EN +2 digit 7 segement blue LED with right hand decimal +0 +10 +10 +Display +HDSP-48xx +10-Element Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Bar Graph Array +0 +20 +20 +Display +HDSP-4830 +10-Element Red Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Bar Graph Array +0 +20 +20 +Display +HDSP-4832 +10-Element Red Yellow Green Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Yellow Green Bar Graph Array +0 +20 +20 +Display +HDSP-4836 +10-Element Red Yellow Green Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Yellow Green Bar Graph Array +0 +20 +20 +Display +HDSP-4840 +10-Element Yellow Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Yellow Bar Graph Array +0 +20 +20 +Display +HDSP-4850 +10-Element Green Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Green Bar Graph Array +0 +20 +20 +Display +HLCP-J100 +10-Element Red Bar Graph Array https://docs.broadcom.com/docs/AV02-1798EN +10-Element Red Bar Graph Array +0 +20 +20 +Display +HY1602E +http://www.icbank.com/data/ICBShop/board/HY1602E.pdf +LCD 16x2 Alphanumeric 16pin +0 +20 +16 +Display +LCD-016N002L +16 x 2 Character LCD, http://www.vishay.com/product?docid=37299 +LCD-016N002L 16 x 2 Character LCD +0 +24 +20 +Display +LM16255 +LCD LM16255 16x2 character http://www.datasheetlib.com/datasheet/259542/lm16255_sharp-electronics.html +LCD 12x2 +0 +14 +14 +Display +NHD-0420H1Z +NHD-0420H1Z LCD http://www.newhavendisplay.com/specs/NHD-0420H1Z-FSW-GBW-33V3.pdf +NHD-0420H1Z LCD +0 +16 +16 +Display +NHD-C0220BiZ +NHD-C0220BiZ LCD http://www.newhavendisplay.com/specs/NHD-C0220BiZ-FSW-FBW-3V3M.pdf +NHD-C0220BiZ LCD +0 +10 +10 +Display +OLED-128O064D +128x64 OLED display +display oled +0 +30 +30 +Display +RC1602A +http://www.raystar-optronics.com/down.php?ProID=18 +LCD 16x2 Alphanumeric 16pin +0 +22 +18 +Display +WC1602A +LCD 16x2 http://www.wincomlcd.com/pdf/WC1602A-SFYLYHTC06.pdf +LCD 16x2 Alphanumeric 16pin +0 +20 +16 +Display_7Segment +7SEGMENT-LED__HDSM531_HDSM533_SMD +7-Segment Display, HDSM53x, https://docs.broadcom.com/docs/AV02-0713EN +7segment LED HDSM531 HDSM533 +0 +10 +10 +Display_7Segment +7SegmentLED_LTS6760_LTS6780 +7-Segment Display, LTS67x0, http://optoelectronics.liteon.com/upload/download/DS30-2001-355/S6760jd.pdf +7Segment LED LTS6760 LTS6780 +0 +10 +10 +Display_7Segment +AD-121F2 +Single Digit 7-segment RGB LED Display, 1-inch digit height, common anode, http://usasyck.com/products/AD-121F2_cat_e.pdf +RGB LED digit +0 +22 +22 +Display_7Segment +AFF_2x7SEG-DIGIT_10mm +Afficheur 7 segments 10mm DIGIT +AFFICHEUR +0 +16 +16 +Display_7Segment +CA56-12CGKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12CGKWA(Ver.9A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12EWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CA56-12EWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SEKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12SEKWA(Ver.7A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SRWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CA56-12SRWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SURKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12SURKWA(Ver.8A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CA56-12SYKWA +4 digit 7 segment green LED, http://www.kingbright.com/attachments/file/psearch/000/00/00/CA56-12SYKWA(Ver.6A).pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CC56-12GWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CA56-11GWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +CC56-12YWA +4 digit 7 segment green LED, http://www.kingbrightusa.com/images/catalog/SPEC/CC56-12YWA.pdf +4 digit 7 segment green LED +0 +12 +12 +Display_7Segment +DA04-11CGKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11CGKWA(Ver.6A).pdf +Dubble digit green 7 segment LED display +0 +16 +16 +Display_7Segment +DA04-11SEKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11SEKWA(Ver.9A).pdf +Dubble digit super bright orange 7 segment LED display +0 +16 +16 +Display_7Segment +DA04-11SURKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11SURKWA(Ver.10A).pdf +Dubble digit hyper red 7 segment LED display +0 +16 +16 +Display_7Segment +DA04-11SYKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA04-11SYKWA(Ver.6A).pdf +Dubble digit super bright yellow 7 segment LED display +0 +16 +16 +Display_7Segment +DA56-11CGKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11CGKWA(Ver.16A).pdf +Double digit seven segment green LED display +0 +18 +18 +Display_7Segment +DA56-11SEKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11SEKWA(Ver.9A).pdf +Double digit seven segment super bright orange LED display +0 +18 +18 +Display_7Segment +DA56-11SURKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11SURKWA(Ver.11A).pdf +Double digit seven segment hyper red LED display +0 +18 +18 +Display_7Segment +DA56-11SYKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/DA56-11SYKWA(Ver.11A).pdf +Double digit seven segment super bright yellow LED display +0 +18 +18 +Display_7Segment +DE113-XX-XX +http://www.display-elektronik.de/filter/DE113-RS-20_635.pdf +3 1/5 digit LOW BAT + 7-Segment LCD +0 +40 +40 +Display_7Segment +DE114-RS-20 +http://www.display-elektronik.de/filter/DE113-RS-20_635.pdf +3 1/5 digit reflective LCD LOW-BAT + 7-Segment +0 +40 +40 +Display_7Segment +DE122-XX-XX +http://www.display-elektronik.de/filter/DE122-RS-20_635.pdf +6 digit 7 segment LCD +0 +50 +50 +Display_7Segment +DE170-XX-XX +http://www.display-elektronik.de/filter/DE170-RS-20_75.pdf +3 1/5 digit reflective arrow bat + 7 segment LCD +0 +40 +40 +Display_7Segment +ELD_426XXXX +http://www.everlight.com/file/ProductFile/D426SYGWA-S530-E2.pdf +Double digit 7 segment brilliant yellow green LED +0 +10 +10 +Display_7Segment +HDSP-7401 +One digit 7 segment yellow, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment yellow +0 +10 +10 +Display_7Segment +HDSP-7507 ++-1 overflow 7 segment high efficiency red, https://docs.broadcom.com/docs/AV02-2553EN ++-1 overflow 7 segment high efficiency red +0 +10 +10 +Display_7Segment +HDSP-7801 +One digit 7 segment green, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment green +0 +10 +10 +Display_7Segment +HDSP-7807 ++-1 overflow 7 segment green, https://docs.broadcom.com/docs/AV02-2553EN ++-1 overflow 7 segment green +0 +10 +10 +Display_7Segment +HDSP-A151 +One digit 7 segment red, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment high efficiency red +0 +10 +10 +Display_7Segment +HDSP-A401 +One digit 7 segment orange, common anode, https://docs.broadcom.com/docs/AV02-2553EN +One digit 7 segment orange common anode +0 +10 +10 +Display_7Segment +KCSC02-105 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-105(Ver.9A).pdf +Single digit 7 segement hyper red LED +0 +10 +10 +Display_7Segment +KCSC02-106 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-106(Ver.10A).pdf +Single digit 7 segement super bright orange LED +0 +10 +10 +Display_7Segment +KCSC02-107 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-107(Ver.9A).pdf +Single digit 7 segement super bright yellow LED +0 +10 +10 +Display_7Segment +KCSC02-123 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-123(Ver.10A).pdf +Single digit 7 segement super bright yellow LED +0 +10 +10 +Display_7Segment +KCSC02-136 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KCSC02-136(Ver.6B).pdf +Single digit 7 segement super bright yellow LED +0 +10 +10 +Display_7Segment +MAN71A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment red LED with right dot +0 +14 +14 +Display_7Segment +MAN72A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment red LED with left dot +0 +14 +14 +Display_7Segment +MAN73A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +Overflow +- 1 red LED +0 +14 +14 +Display_7Segment +MAN3410A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment green LED with dot +0 +14 +14 +Display_7Segment +MAN3420A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment green LED with left dot +0 +14 +14 +Display_7Segment +MAN3610A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment orange LED with right dot +0 +14 +14 +Display_7Segment +MAN3620A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment orange LED with left dot +0 +14 +14 +Display_7Segment +MAN3630A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +Overflow +- 1 orange LED +0 +14 +14 +Display_7Segment +MAN3810A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment yellow LED with right dot +0 +14 +14 +Display_7Segment +MAN3820A +https://www.digchip.com/datasheets/parts/datasheet/161/MAN3640A-pdf.php +One digit 7 segment yellow LED with left dot +0 +14 +14 +Display_7Segment +SA15-11xxx +http://www.kingbrightusa.com/images/catalog/SPEC/SA15-11SRWA.pdf +SA15-11xxx single digit 7 segment display 38.1mm 1.5inch +0 +10 +10 +Display_7Segment +SBC18-11SURKCGKWA +http://www.kingbright.com/attachments/file/psearch/000/00/00/SBC18-11SURKCGKWA(Ver.6A).pdf +single digit 7 segemnt red/green LED +0 +10 +10 +Display_7Segment +Sx39-1xxxxx +Single digit 7 segment LED display in red, yellow or green colour http://www.kingbrightusa.com/images/catalog/SPEC/sa39-11ewa.pdf +One digit LED 7 segment SA39-11 SC39-11 SA39-12 SC39-12 +0 +10 +10 +Ferrite_THT +LairdTech_28C0236-0JW-10 +Ferrite, vertical, LairdTech 28C0236-0JW-10, https://assets.lairdtech.com/home/brandworld/files/28C0236-0JW-10.pdf, JW Miller core https://www.bourns.com/products/magnetic-products/j.w.-miller-through-hole-ferrite-beads-emi-filters +Ferrite vertical LairdTech 28C0236-0JW-10 +0 +2 +2 +Fiducial +Fiducial_0.5mm_Mask1.5mm +Circular Fiducial, 0.5mm bare copper, 1.5mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_0.5mm_Mask1mm +Circular Fiducial, 0.5mm bare copper, 1mm soldermask opening (Level C) +fiducial +0 +1 +0 +Fiducial +Fiducial_0.75mm_Mask1.5mm +Circular Fiducial, 0.75mm bare copper, 1.5mm soldermask opening (Level B) +fiducial +0 +1 +0 +Fiducial +Fiducial_0.75mm_Mask2.25mm +Circular Fiducial, 0.75mm bare copper, 2.25mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_1.5mm_Mask3mm +Circular Fiducial, 1.5mm bare copper, 3mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_1.5mm_Mask4.5mm +Circular Fiducial, 1.5mm bare copper, 4.5mm soldermask opening +fiducial +0 +1 +0 +Fiducial +Fiducial_1mm_Mask2mm +Circular Fiducial, 1mm bare copper, 2mm soldermask opening (Level A) +fiducial +0 +1 +0 +Fiducial +Fiducial_1mm_Mask3mm +Circular Fiducial, 1mm bare copper, 3mm soldermask opening (recommended) +fiducial +0 +1 +0 +Filter +Filter_1109-5_1.1x0.9mm +5-pin SAW filter package - 1.1x0.9 mm Body; (see https://www.murata.com/~/media/webrenewal/support/library/catalog/products/filter/rf/p73e.ashx?la=en-gb) +Filter 5 +0 +5 +5 +Filter +Filter_1411-5_1.4x1.1mm +5-pin filter package - 1.4x1.1 mm Body; (see https://global.kyocera.com/prdct/electro/product/pdf/sf14_tdlte.pdf) +Filter 5 +0 +5 +5 +Filter +Filter_Bourns_SRF0905_6.0x9.2mm +https://www.bourns.com/docs/Product-Datasheets/SRF0905.pdf +Line Filter +0 +4 +4 +Filter +Filter_FILTERCON_1FPxx +0.5A, 250VAC, 50/60Hz line filter (https://filtercon.com.pl/wp-content/uploads/2019/07/Karta-katalogowa-FP-12-1.pdf) +EMI filter +0 +4 +4 +Filter +Filter_Mini-Circuits_FV1206 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206.pdf +Mini-Circuits Filter SMD 1206 +0 +6 +4 +Filter +Filter_Mini-Circuits_FV1206-1 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-1.pdf +Mini-Circuits Filter SMD 1206 +0 +6 +6 +Filter +Filter_Mini-Circuits_FV1206-4 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-4.pdf +Mini-Circuits Filter SMD 1206 +0 +8 +4 +Filter +Filter_Mini-Circuits_FV1206-5 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-5.pdf +Mini-Circuits Filter SMD 1206 +0 +8 +4 +Filter +Filter_Mini-Circuits_FV1206-6 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-6.pdf +Mini-Circuits Filter SMD 1206 +0 +14 +8 +Filter +Filter_Mini-Circuits_FV1206-7 +Mini-Circuits Filter SMD 1206 https://ww2.minicircuits.com/case_style/FV1206-7.pdf +Mini-Circuits Filter SMD 1206 +0 +5 +3 +Filter +Filter_Murata_BNX025 +https://www.murata.com/en-us/products/productdata/8796778004510/QNFH9101.pdf?1496719830000 +EMI Filter +0 +6 +4 +Filter +Filter_Murata_BNX025_ThermalVias +https://www.murata.com/en-us/products/productdata/8796778004510/QNFH9101.pdf?1496719830000 +EMI Filter +0 +19 +4 +Filter +Filter_Schaffner_FN405 +Compact PCB mounting EMI filter (https://www.schaffner.com/de/produkte/download/product/datasheet/fn-405-pcb-mounting-filter/) +EMI filter +0 +5 +5 +Filter +Filter_Schaffner_FN406 +Ultra Compact EMC Filter (https://www.schaffner.com/products/download/product/datasheet/fn-406-ultra-compact-emc-filter/) +emi filter +0 +5 +5 +Fuse +Fuse_0402_1005Metric +Fuse SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_0402_1005Metric_Castellated +Fuse SMD 0402 (1005 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_0402_1005Metric_Pad0.77x0.64mm_HandSolder +Fuse SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_0603_1608Metric +Fuse SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_0603_1608Metric_Castellated +Fuse SMD 0603 (1608 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_0603_1608Metric_Pad1.05x0.95mm_HandSolder +Fuse SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_0805_2012Metric +Fuse SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_0805_2012Metric_Castellated +Fuse SMD 0805 (2012 Metric), castellated end terminal, IPC_7351. (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_0805_2012Metric_Pad1.15x1.40mm_HandSolder +Fuse SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_1206_3216Metric +Fuse SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_1206_3216Metric_Castellated +Fuse SMD 1206 (3216 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_1206_3216Metric_Pad1.42x1.75mm_HandSolder +Fuse SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_1210_3225Metric +Fuse SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_1210_3225Metric_Castellated +Fuse SMD 1210 (3225 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_1210_3225Metric_Pad1.42x2.65mm_HandSolder +Fuse SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_1812_4532Metric +Fuse SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_1812_4532Metric_Castellated +Fuse SMD 1812 (4532 Metric), castellated end terminal, IPC_7351. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Fuse SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2010_5025Metric +Fuse SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2010_5025Metric_Castellated +Fuse SMD 2010 (5025 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2010_5025Metric_Pad1.52x2.65mm_HandSolder +Fuse SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2512_6332Metric +Fuse SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2512_6332Metric_Castellated +Fuse SMD 2512 (6332 Metric), castellated end terminal, IPC_7351. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2512_6332Metric_Pad1.52x3.35mm_HandSolder +Fuse SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2816_7142Metric +Fuse SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2816_7142Metric_Castellated +Fuse SMD 2816 (7142 Metric), castellated end terminal, IPC_7351. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Fuse SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_2920_7451Metric +Fuse SMD 2920 (7451 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://www.megastar.com/products/fusetronic/polyswitch/PDF/smd2920.pdf), generated with kicad-footprint-generator +fuse +0 +2 +2 +Fuse +Fuse_2920_7451Metric_Castellated +Fuse SMD 2920 (7451 Metric), castellated end terminal, IPC_7351. (Body size from: http://www.megastar.com/products/fusetronic/polyswitch/PDF/smd2920.pdf), generated with kicad-footprint-generator +fuse castellated +0 +2 +2 +Fuse +Fuse_2920_7451Metric_Pad2.10x5.45mm_HandSolder +Fuse SMD 2920 (7451 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://www.megastar.com/products/fusetronic/polyswitch/PDF/smd2920.pdf), generated with kicad-footprint-generator +fuse handsolder +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0005FF_L8.3mm_W3.8mm +Fuse 0ZRE0005FF, BelFuse, Radial Leaded PTC, https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0008FF_L8.3mm_W3.8mm +Fuse 0ZRE0008FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0012FF_L8.3mm_W3.8mm +Fuse 0ZRE0012FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0016FF_L9.9mm_W3.8mm +Fuse 0ZRE0016FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0025FF_L9.6mm_W3.8mm +Fuse 0ZRE0025FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0033FF_L11.4mm_W3.8mm +Fuse 0ZRE0033FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0040FF_L11.5mm_W3.8mm +Fuse 0ZRE0040FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0055FF_L14.0mm_W4.1mm +Fuse 0ZRE0055FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0075FF_L11.5mm_W4.8mm +Fuse 0ZRE0075FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0100FF_L18.7mm_W5.1mm +Fuse 0ZRE0100FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0125FF_L21.2mm_W5.3mm +Fuse 0ZRE0125FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0150FF_L23.4mm_W5.3mm +Fuse 0ZRE0150FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_BelFuse_0ZRE0200FF_L24.9mm_W6.1mm +Fuse 0ZRE0200FF, BelFuse, Radial Leaded PTC,https://www.belfuse.com/resources/datasheets/circuitprotection/ds-cp-0zre-series.pdf +0ZRE BelFuse radial PTC +0 +2 +2 +Fuse +Fuse_Blade_ATO_directSolder +car blade fuse direct solder +car blade fuse +0 +2 +2 +Fuse +Fuse_Blade_Mini_directSolder +car blade fuse mini, direct solder +car blade fuse mini +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG300 +PTC Resettable Fuse, Ihold = 3.0A, Itrip=5.1A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG400 +PTC Resettable Fuse, Ihold = 4.0A, Itrip=6.8A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG500 +PTC Resettable Fuse, Ihold = 5.0A, Itrip=8.5A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG600 +PTC Resettable Fuse, Ihold = 6.0A, Itrip=10.2A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG650 +PTC Resettable Fuse, Ihold = 6.5A, Itrip=11.1A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG700 +PTC Resettable Fuse, Ihold = 7.0A, Itrip=11.9A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG800 +PTC Resettable Fuse, Ihold = 8.0A, Itrip=13.6A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG900 +PTC Resettable Fuse, Ihold = 9.0A, Itrip=15.3A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG1000 +PTC Resettable Fuse, Ihold = 10.0A, Itrip=17.0A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RG1100 +PTC Resettable Fuse, Ihold = 11.0A, Itrip=18.7A, http://www.bourns.com/docs/Product-Datasheets/mfrg.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT050 +PTC Resettable Fuse, Ihold = 0.5A, Itrip=0.92A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT070 +PTC Resettable Fuse, Ihold = 0.7A, Itrip=1.4A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT100 +PTC Resettable Fuse, Ihold = 1.0A, Itrip=1.8A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT200 +PTC Resettable Fuse, Ihold = 2.0A, Itrip=3.8A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT300 +PTC Resettable Fuse, Ihold = 3.0A, Itrip=6.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT400 +PTC Resettable Fuse, Ihold = 4.0A, Itrip=7.5A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT500 +PTC Resettable Fuse, Ihold = 5.0A, Itrip=9.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT550 +PTC Resettable Fuse, Ihold = 5.5A, Itrip=10.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT600 +PTC Resettable Fuse, Ihold = 6.0A, Itrip=10.8A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT650 +PTC Resettable Fuse, Ihold = 6.5A, Itrip=12.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT700 +PTC Resettable Fuse, Ihold = 7.0A, Itrip=13.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT750 +PTC Resettable Fuse, Ihold = 7.5A, Itrip=13.1A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT800 +PTC Resettable Fuse, Ihold = 8.0A, Itrip=15.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT900 +PTC Resettable Fuse, Ihold = 9.0A, Itrip=16.5A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT1000 +PTC Resettable Fuse, Ihold = 10.0A, Itrip=18.5A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT1100 +PTC Resettable Fuse, Ihold = 11.0A, Itrip=20.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-RHT1300 +PTC Resettable Fuse, Ihold = 13.0A, Itrip=24.0A, http://www.bourns.com/docs/product-datasheets/mfrht.pdf +ptc resettable fuse polyfuse THT +0 +2 +2 +Fuse +Fuse_Bourns_MF-SM_7.98x5.44mm +https://www.bourns.com/docs/Product-Datasheets/mfsm.pdf +bourns ptc resettable fuse polyfuse MF-SM MF-SMHT +0 +2 +2 +Fuse +Fuse_Bourns_MF-SM_9.5x6.71mm +https://www.bourns.com/docs/Product-Datasheets/mfsm.pdf +bourns ptc resettable fuse polyfuse MF-SM MF-SMHT +0 +2 +2 +Fuse +Fuse_Littelfuse-LVR100 +Littelfuse, resettable fuse, PTC, polyswitch LVR100, Ih 1A http://www.littelfuse.com/~/media/electronics/datasheets/resettable_ptcs/littelfuse_ptc_lvr_catalog_datasheet.pdf.pdf +LVR100 PTC resettable polyswitch +0 +2 +2 +Fuse +Fuse_Littelfuse-LVR125 +Littelfuse, resettable fuse, PTC, polyswitch LVR125, Ih 1.25A, http://www.littelfuse.com/~/media/electronics/datasheets/resettable_ptcs/littelfuse_ptc_lvr_catalog_datasheet.pdf.pdf +LVR125 PTC resettable polyswitch +0 +2 +2 +Fuse +Fuse_Littelfuse-LVR200 +Littelfuse, resettable fuse, PTC, polyswitch LVR200, Ih 2A, http://www.littelfuse.com/~/media/electronics/datasheets/resettable_ptcs/littelfuse_ptc_lvr_catalog_datasheet.pdf.pdf +LVR200 PTC resettable polyswitch +0 +2 +2 +Fuse +Fuse_Littelfuse-NANO2-451_453 +Littelfuse NANO2 https://www.littelfuse.com/~/media/electronics/datasheets/fuses/littelfuse_fuse_451_453_datasheet.pdf.pdf +Fuse Nano2 +0 +2 +2 +Fuse +Fuse_Littelfuse_372_D8.50mm +Fuse, Littelfuse, 372, 8.5x8mm, https://www.littelfuse.com/~/media/electronics/datasheets/fuses/littelfuse_fuse_372_datasheet.pdf.pdf +fuse tht radial +0 +2 +2 +Fuse +Fuse_Littelfuse_395Series +Fuse, TE5, Littelfuse/Wickmann, No. 460, No560, +Fuse TE5 Littelfuse/Wickmann No. 460 No560 +0 +2 +2 +Fuse +Fuse_Schurter_UMT250 +Surface Mount Fuse, 3 x 10.1 mm, Time-Lag T, 250 VAC, 125 VDC (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_UMT_250.pdf) +Schurter fuse smd +0 +2 +2 +Fuse +Fuse_Schurter_UMZ250 +Surface Mount Fuse with Clip, 4.2 x 11.1 mm, Time-Lag T, 250 VAC, 125 VDC (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_UMZ_250.pdf) +fuse smd mount holder +0 +2 +2 +Fuse +Fuse_SunFuse-6HP +SunFuse Ceramic Slow Blow Fuse 6H_6HP.PDF +UL/CSA 6x32mm Ceramic Slow Blow Fuse +0 +2 +2 +Fuse +Fuseholder_Blade_ATO_Littelfuse_Pudenz_2_Pin +Fuseholder ATO Blade littelfuse Pudenz 2 Pin +Fuseholder ATO Blade littelfuse Pudenz 2 Pin +0 +2 +2 +Fuse +Fuseholder_Blade_Mini_Keystone_3568 +fuse holder, car blade fuse mini, http://www.keyelco.com/product-pdf.cfm?p=306 +car blade fuse mini +0 +4 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Bulgin_FX0456_Vertical_Closed +Fuseholder, 5x20, closed, vertical, Bulgin, FX0456, https://www.bulgin.com/products/pub/media/bulgin/data/Fuseholders.pdf +Fuseholder 5x20 closed vertical Bulgin FX0456 Sicherungshalter +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Bulgin_FX0457_Horizontal_Closed +Fuseholder, 5x20, closed, horizontal, Bulgin, FX0457, Sicherungshalter, +Fuseholder 5x20 closed horizontal Bulgin FX0457 Sicherungshalter +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_EATON_H15-V-1_Vertical_Closed +PCB fuse holders for 5 mm x 20 mm fuses; 250V; 10A (http://www.cooperindustries.com/content/dam/public/bussmann/Electronics/Resources/product-datasheets/bus-elx-ds-4426-h15.pdf) +fuse holder vertical 5x20mm +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_EATON_HBV_Vertical_Closed +5 mm x 20 mm fuse holders; Vertical w/ Stability Pins; 250V; 6.3-16A (http://www.cooperindustries.com/content/dam/public/bussmann/Electronics/Resources/product-datasheets/Bus_Elx_DS_2118_HB_PCB_Series.pdf) +fuse holder vertical 5x20mm +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_EATON_HBW_Vertical_Closed +5 mm x 20 mm fuse holders; Vertical w/o Stability Pins; 250V; 6.3-16A (http://www.cooperindustries.com/content/dam/public/bussmann/Electronics/Resources/product-datasheets/Bus_Elx_DS_2118_HB_PCB_Series.pdf) +fuse holder vertical 5x20mm +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_0031_8201_Horizontal_Open +Fuseholder horizontal open, 5x20mm, 500V, 16A, Schurter 0031.8201, https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_OGN.pdf +Fuseholder horizontal open 5x20 Schurter 0031.8201 +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_FAB_0031-355x_Horizontal_Closed +Fuseholder 5x20mm horizontal Shurter model FAB, Suitable for order numbers 0031.3551 and 0031.3558 (https://www.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FAB.pdf) +Fuseholder 5x20mm closed horizontal +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_FPG4_Vertical_Closed +Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap/Fingergrip, vertical, IEC 60335-1; 250VAC/10A VDE; 500V/16A UL/CSA (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FPG4.pdf) +fuse holder vertical 5x20mm +0 +4 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_FUP_0031.2510_Horizontal_Closed +Shock-Safe closed Fuseholder, Schurter FUP Series, 5.0 x 20mm, Slotted Cap, horizontal, 500 VAC 4W/16A (VDE), 600V 30A (UL/CSA), order numbers: 0031.2510 (0031.2500 + 0031.2323), http://www.schurter.ch/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FUP.pdf +Fuseholder 5x20mm horizontal closed +0 +3 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Schurter_OGN-SMD_Horizontal_Open +Fuseholder horizontal open, 5x20mm, 500V, 16A (https://us.schurter.com/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_OGN-SMD.pdf) +Fuseholder horizontal open 5x20 Schurter 0031.8221 +0 +2 +2 +Fuse +Fuseholder_Cylinder-5x20mm_Stelvio-Kontek_PTF78_Horizontal_Open +https://www.tme.eu/en/Document/3b48dbe2b9714a62652c97b08fcd464b/PTF78.pdf +Fuseholder horizontal open 5x20 Stelvio-Kontek PTF/78 +0 +2 +2 +Fuse +Fuseholder_Cylinder-6.3x32mm_Schurter_0031-8002_Horizontal_Open +Fuseholder, horizontal, open, 6.3x32, Schurter, 0031.8002, https://www.schurter.com/en/datasheet/typ_OG__Holder__6.3x32.pdf +Fuseholder horizontal open 6.3x32 Schurter 0031.8002 +0 +2 +2 +Fuse +Fuseholder_Cylinder-6.3x32mm_Schurter_FUP_0031.2520_Horizontal_Closed +Shock-Safe closed Fuseholder, Schurter FUP Series, 6.3 x 32 mm, Slotted Cap, horizontal, 500 VAC 4W/16A (VDE), 600V 30A (UL/CSA), order numbers: 0031.2520 (0031.2500 + 0031.2321), http://www.schurter.ch/bundles/snceschurter/epim/_ProdPool_/newDS/en/typ_FUP.pdf +Fuseholder 6.3x32mm horizontal closed +0 +3 +2 +Fuse +Fuseholder_Littelfuse_Nano2_157x +Littelfuse NANO2 holder, https://www.littelfuse.com/~/media/electronics/datasheets/fuses/littelfuse_fuse_157_datasheet.pdf.pdf +SMD Nano2 holder +0 +2 +2 +Fuse +Fuseholder_TR5_Littelfuse_No560_No460 +Fuse, Fuseholder, TR5, Littelfuse/Wickmann, No. 460, No560, https://www.littelfuse.com/~/media/electronics/datasheets/fuse_holders/littelfuse_fuse_holder_559_560_datasheet.pdf.pdf +Fuse Fuseholder TR5 Littelfuse/Wickmann No. 460 No560 +0 +2 +2 +Heatsink +Heatsink_35x26mm_1xFixation3mm_Fischer-SK486-35 +Heatsink, 35mm x 26mm, 1x Fixation 3mm, Fischer SK486-35 +heatsink +0 +1 +1 +Heatsink +Heatsink_38x38mm_SpringFixation +Heatsink, 38x38mm, Spring Fixation, diagonal, +heatsink +0 +4 +1 +Heatsink +Heatsink_62x40mm_2xFixation3mm +Heatsink, 62 x 40mm, 2x 3mm Drills, +heatsink +0 +2 +1 +Heatsink +Heatsink_125x35x50mm_3xFixationM3 +Heatsink, 125x35x50mm, 3 fixation holes 3.2mm +heatsink +0 +0 +0 +Heatsink +Heatsink_AAVID_573300D00010G_TO-263 +Heatsink, 12.70mm x 26.16mm x 10.16, SMD, 18K/W, TO-263, D2 Pak, https://www.shopaavid.com/Product/573300D00000G +Heatsink AAVID TO-263 D2 Pak +0 +2 +1 +Heatsink +Heatsink_Aavid-TV5G_TO220_Horizontal +Heatsink TV5G TO-220 Horizontal, https://www.shopaavid.com/Product/TV-5G +Heatsink TV5G TO-220 Horizontal +0 +0 +0 +Heatsink +Heatsink_Fischer_FK224xx2201_25x8.3mm +25x8.3mm Heatsink, 18K/W, TO-220, https://www.fischerelektronik.de/web_fischer/en_GB/$catalogue/fischerData/PR/FK224_220_1_/datasheet.xhtml?branch=heatsinks +heatsink TO-220 +0 +2 +1 +Heatsink +Heatsink_Fischer_FK24413D2PAK_26x13mm +26x13 mm SMD heatsink for TO-252 TO-263 TO-268, https://www.fischerelektronik.de/pim/upload/fischerData/cadpdf/base/fk_244_13_d2_pak.pdf +heatsink TO-252 TO-263 TO-268 +0 +2 +1 +Heatsink +Heatsink_Fischer_SK104-STC-STIC_35x13mm_2xDrill2.5mm +Heatsink, 35mm x 13mm, 2x Fixation 2,5mm Drill, Soldering, Fischer SK104-STC-STIC, +Heatsink fischer TO-220 +0 +2 +1 +Heatsink +Heatsink_Fischer_SK104-STCB_35x13mm__2xDrill3.5mm_ScrewM3 +Heatsink, 35mm x 13mm, 2x Fixation 2,5mm Drill, Soldering, Fischer SK104-STC-STIC, +Heatsink fischer TO-220 +0 +2 +1 +Heatsink +Heatsink_Fischer_SK129-STS_42x25mm_2xDrill2.5mm +Heatsink, Fischer SK129 +heatsink fischer +0 +2 +1 +Heatsink +Heatsink_SheetType_50x7mm_2Fixations +Heatsink, Sheet type, 50x7mm, 2 fixations (solder), +Heatsink sheet +0 +2 +1 +Heatsink +Heatsink_Stonecold_HS-132_32x14mm_2xFixation1.5mm +Heatsink, StoneCold HS +heatsink +0 +2 +1 +Inductor_SMD +L_6.3x6.3_H3 +Choke, SMD, 6.3x6.3mm 3mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_7.3x7.3_H3.5 +Choke, SMD, 7.3x7.3mm 3.5mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_7.3x7.3_H4.5 +Choke, SMD, 7.3x7.3mm 4.5mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_10.4x10.4_H4.8 +Choke, SMD, 10.4x10.4mm 4.8mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_12x12mm_H4.5mm +Choke, SMD, 12x12mm 4.5mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_12x12mm_H6mm +Choke, SMD, 12x12mm 6mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_12x12mm_H8mm +Choke, SMD, 12x12mm 8mm height +Choke SMD +0 +2 +2 +Inductor_SMD +L_0201_0603Metric +Inductor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +inductor +0 +4 +2 +Inductor_SMD +L_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Inductor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +4 +2 +Inductor_SMD +L_0402_1005Metric +Inductor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_0402_1005Metric_Pad0.77x0.64mm_HandSolder +Inductor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_0603_1608Metric +Inductor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_0603_1608Metric_Pad1.05x0.95mm_HandSolder +Inductor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_0805_2012Metric +Inductor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_0805_2012Metric_Pad1.05x1.20mm_HandSolder +Inductor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_0805_2012Metric_Pad1.15x1.40mm_HandSolder +Inductor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_01005_0402Metric +Inductor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +inductor +0 +4 +2 +Inductor_SMD +L_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Inductor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +4 +2 +Inductor_SMD +L_1008_2520Metric +Inductor SMD 1008 (2520 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://ecsxtal.com/store/pdf/ECS-MPI2520-SMD-POWER-INDUCTOR.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1008_2520Metric_Pad1.43x2.20mm_HandSolder +Inductor SMD 1008 (2520 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://ecsxtal.com/store/pdf/ECS-MPI2520-SMD-POWER-INDUCTOR.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1206_3216Metric +Inductor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1206_3216Metric_Pad1.22x1.90mm_HandSolder +Inductor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1206_3216Metric_Pad1.42x1.75mm_HandSolder +Inductor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1210_3225Metric +Inductor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1210_3225Metric_Pad1.42x2.65mm_HandSolder +Inductor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1806_4516Metric +Inductor SMD 1806 (4516 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.modelithics.com/models/Vendor/MuRata/BLM41P.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1806_4516Metric_Pad1.57x1.80mm_HandSolder +Capacitor SMD 1806 (4516 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.modelithics.com/models/Vendor/MuRata/BLM41P.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_1812_4532Metric +Inductor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Inductor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_2010_5025Metric +Inductor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_2010_5025Metric_Pad1.52x2.65mm_HandSolder +Inductor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_2512_6332Metric +Inductor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_2512_6332Metric_Pad1.52x3.35mm_HandSolder +Inductor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_2816_7142Metric +Inductor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +inductor +0 +2 +2 +Inductor_SMD +L_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Inductor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +inductor handsolder +0 +2 +2 +Inductor_SMD +L_Abracon_ASPI-0630LR +smd shielded power inductor https://abracon.com/Magnetics/power/ASPI-0630LR.pdf +inductor abracon smd shielded +0 +2 +2 +Inductor_SMD +L_Abracon_ASPI-3012S +smd shielded power inductor http://www.abracon.com/Magnetics/power/ASPI-3012S.pdf +inductor abracon smd shielded +0 +2 +2 +Inductor_SMD +L_Bourns-SRN1060 +Bourns SRN1060 series SMD inductor https://www.bourns.com/docs/Product-Datasheets/SRN1060.pdf +Bourns SRN1060 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRN4018 +Bourns SRN4018 series SMD inductor, https://www.bourns.com/docs/Product-Datasheets/SRN4018.pdf +Bourns SRN4018 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRN6028 +Bourns SRN6028 series SMD inductor +Bourns SRN6028 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRN8040_8x8.15mm +Bourns SRN8040 series SMD inductor 8x8.15mm, https://www.bourns.com/docs/Product-Datasheets/SRN8040.pdf +Bourns SRN8040 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRR1005 +Bourns SRR1005 series SMD inductor +Bourns SRR1005 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRU1028_10.0x10.0mm +Bourns SRU1028 series SMD inductor, https://www.bourns.com/docs/Product-Datasheets/SRU1028.pdf +Bourns SRU1028 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRU8028_8.0x8.0mm +Bourns SRU8028 series SMD inductor +Bourns SRU8028 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns-SRU8043 +Bourns SRU8043 series SMD inductor +Bourns SRU8043 SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SDR1806 +https://www.bourns.com/docs/Product-Datasheets/SDR1806.pdf +Bourns SDR1806 +0 +2 +2 +Inductor_SMD +L_Bourns_SRF1260 +Inductor, Bourns, SRF1260, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://www.bourns.com/docs/Product-Datasheets/SRF1260.pdf) +Inductor Bourns_SRF1260 +0 +4 +4 +Inductor_SMD +L_Bourns_SRN6045TA +http://www.bourns.com/docs/product-datasheets/srn6045ta.pdf +Semi-shielded Power Inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRN8040TA +https://www.bourns.com/docs/product-datasheets/srn8040ta.pdf +Inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRP1245A +Bourns SRP1245A series SMD inductor http://www.bourns.com/docs/Product-Datasheets/SRP1245A.pdf +Bourns SRP1245A SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRP2313AA +Bourns SRR1260 series SMD inductor http://www.bourns.com/docs/product-datasheets/srp2313aa.pdf +Bourns SRR1260 SMD inductor +0 +4 +2 +Inductor_SMD +L_Bourns_SRP5030T +Inductor, Bourns, SRP5030T, 5.7mmx5.2mm (Script generated with StandardBox.py) (https://www.bourns.com/data/global/pdfs/SRP5030T.pdf) +Inductor Bourns_SRP5030T +0 +2 +2 +Inductor_SMD +L_Bourns_SRP7028A_7.3x6.6mm +Shielded Power Inductors (https://www.bourns.com/docs/product-datasheets/srp7028a.pdf) +Shielded Inductors Bourns SMD SRP7028A +0 +2 +2 +Inductor_SMD +L_Bourns_SRR1210A +Bourns SRR1210A series SMD inductor https://www.bourns.com/docs/Product-Datasheets/SRR1210A.pdf +Bourns SRR1210A SMD inductor +0 +2 +2 +Inductor_SMD +L_Bourns_SRR1260 +Bourns SRR1260 series SMD inductor http://www.bourns.com/docs/Product-Datasheets/SRR1260.pdf +Bourns SRR1260 SMD inductor +0 +2 +2 +Inductor_SMD +L_Coilcraft_LPS4018 +SMD Inductor Coilcraft LPS4018 https://www.coilcraft.com/pdfs/lps4018.pdf +L Coilcraft LPS4018 +0 +2 +2 +Inductor_SMD +L_Coilcraft_LPS5030 +Shielded Power Inductor SMD, Coilcraft LPS5030, https://www.coilcraft.com/pdfs/lps5030.pdf, StepUp generated footprint +inductor +0 +2 +2 +Inductor_SMD +L_Coilcraft_XAL60xx_6.36x6.56mm +Coilcraft XAL60xx series, https://www.coilcraft.com/pdfs/xal60xx.pdf +L Coilcraft XAL60xx +0 +2 +2 +Inductor_SMD +L_Coilcraft_XAL5030 +L_Coilcraft_XAL5030 +L Coilcraft XAL5030 +0 +2 +2 +Inductor_SMD +L_Coilcraft_XxL4020 +L_Coilcraft_XxL4020 https://www.coilcraft.com/pdfs/xfl4020.pdf +L Coilcraft XxL4020 +0 +2 +2 +Inductor_SMD +L_Coilcraft_XxL4030 +L_Coilcraft_XxL4030 https://www.coilcraft.com/pdfs/xfl4030.pdf +L Coilcraft XxL4030 +0 +2 +2 +Inductor_SMD +L_Coilcraft_XxL4040 +L_Coilcraft_XxL4040 https://www.coilcraft.com/pdfs/xal4000.pdf +L Coilcraft XxL4040 +0 +2 +2 +Inductor_SMD +L_CommonModeChoke_Coilcraft_0603USB +Coilcraft 0603USB Series Common Mode Choke, https://www.coilcraft.com/pdfs/0603usb.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonModeChoke_Coilcraft_0805USB +Coilcraft 0805USB Series Common Mode Choke, https://www.coilcraft.com/pdfs/0805usb.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonModeChoke_Coilcraft_1812CAN +Coilcraft 1812CAN Series Common Mode Choke, https://www.coilcraft.com/pdfs/1812can.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonModeChoke_Wuerth_WE-SL5 +WE-SL5 SMT Common Mode Line Filter, https://www.we-online.de/katalog/en/WE-SL5/, https://www.we-online.de/katalog/datasheet/744272471.pdf +SMT Common Mode Line Filter +0 +4 +4 +Inductor_SMD +L_CommonMode_Delevan_4222 +API Delevan, Surface Mount Common Mode Bead, 4222 4222R, http://www.delevan.com/seriesPDFs/4222.pdf +surface mount common mode bead +0 +4 +4 +Inductor_SMD +L_CommonMode_Wuerth_WE-SL2 +http://katalog.we-online.de/en/pbs/WE-SL2?sid=5fbec16187#vs_t1:c1_ct:1 +Wuerth WE-SL2 +0 +4 +4 +Inductor_SMD +L_Fastron_PISN +Choke, Drossel, PISN, SMD, Fastron, +Choke Drossel PISN SMD Fastron +0 +2 +2 +Inductor_SMD +L_Fastron_PISN_Handsoldering +Choke, Drossel, PISN, SMD, Fastron, +Choke Drossel PISN SMD Fastron +0 +2 +2 +Inductor_SMD +L_Fastron_PISR +Choke, Drossel, PISR, Fastron, SMD, +Choke Drossel PISR Fastron SMD +0 +2 +2 +Inductor_SMD +L_Fastron_PISR_Handsoldering +Choke, Drossel, PISR, Fastron, SMD, +Choke Drossel PISR Fastron SMD +0 +2 +2 +Inductor_SMD +L_Murata_DEM35xxC +https://www.murata.com/~/media/webrenewal/products/inductor/chip/tokoproducts/wirewoundferritetypeforpl/m_dem3518c.ashx +Inductor SMD DEM35xxC +0 +2 +2 +Inductor_SMD +L_Murata_LQH2MCNxxxx02_2.0x1.6mm +Inductor, Murata, LQH2MCN_02 series, 1.6x2.0x0.9mm (https://search.murata.co.jp/Ceramy/image/img/P02/JELF243A-0053.pdf) +chip coil inductor Murata LQH2MC +0 +2 +2 +Inductor_SMD +L_Murata_LQH55DN_5.7x5.0mm +Inductor, SMD, 5.7x5.0x4.7mm, https://search.murata.co.jp/Ceramy/image/img/P02/JELF243A-0045.pdf +inductor smd +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_1turn_HDM0131A +Neosid, Air-Coil, SML, 1turn, HDM0131A, +Neosid Air-Coil SML 1turn HDM0131A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_2turn_HAM0231A +Neosid, Air-Coil, SML, 2turn, HAM0231A, +Neosid Air-Coil SML 2turn HAM0231A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_2turn_HDM0231A +Neosid, Air-Coil, SML, 2turn, HDM0231A, +Neosid Air-Coil SML 2turn HDM0231A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_3turn_HAM0331A +Neosid, Air-Coil, SML, 2turn, HAM0331A, +Neosid Air-Coil SML 3turn HAM0331A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_3turn_HDM0331A +Neosid, Air-Coil, SML, 3turn, HDM0331A, +Neosid Air-Coil SML 3turn HDM0331A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_4turn_HAM0431A +Neosid, Air-Coil, SML, 4turn, HAM0431A, +Neosid Air-Coil SML 4turn HAM0431A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_4turn_HDM0431A +Neosid, Air-Coil, SML, 4turn, HDM0431A, +Neosid Air-Coil SML 4turn HDM0431A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_5turn_HAM0531A +Neosid, Air-Coil, SML, 5turn, HAM0531A, +Neosid Air-Coil SML 5turn HAM0531A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_5turn_HDM0531A +Neosid, Air-Coil, SML, 5turn, HDM0531A, +Neosid Air-Coil SML 5turn HDM0531A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_6-10turn_HAM0631A-HAM1031A +Neosid, Air-Coil, SML, 6-10turn, HAM0631A-HAM1031A, +Neosid Air-Coil SML 6-10turn HAM0631A-HAM1031A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_6-10turn_HDM0431A-HDM1031A +Neosid, Air-Coil, SML, 6-10turn, HDM0431A-HDM1031A, +Neosid Air-Coil SML 6-10turn HDM0431A-HDM1031A +0 +2 +2 +Inductor_SMD +L_Neosid_Air-Coil_SML_6turn_HAM0631A +Neosid, Air-Coil, SML, 6turn, HAM0631A, +Neosid Air-Coil SML 6turn HAM0631A +0 +2 +2 +Inductor_SMD +L_Neosid_MicroCoil_Ms36-L +Neosid, Micro Coil, Inductor, Ms36-L, SMD, Fixed inductor, anti clockwise, https://neosid.de/en/products/inductors/rod-core-chokes/smd-rod-core-chokes/52026/ms-36/7-h?c=94 +Neosid Micro Coil Inductor Ms36-L SMD Fixed inductor anti clockwise +0 +2 +2 +Inductor_SMD +L_Neosid_Ms42 +Neosid, Inductor, SMs42, Fixed inductor, SMD, magneticaly shielded, https://neosid.de/import-data/product-pdf/neoFestind_Ms42.pdf +Neosid Inductor SMs42 Fixed inductor SMD magneticaly shielded +0 +2 +2 +Inductor_SMD +L_Neosid_Ms50 +Neosid, Power Inductor, Ms50, SMD, Fixed inductor, https://neosid.de/import-data/product-pdf/neoFestind_Ms50.pdf +Neosid Power Inductor Ms50 SMD Fixed inductor +0 +2 +2 +Inductor_SMD +L_Neosid_Ms50T +Neosid, Power Inductor, Ms50T, SMD, Fixed inductor, high temperature, https://neosid.de/import-data/product-pdf/neoFestind_Ms50T.pdf +Neosid Power Inductor Ms50T SMD Fixed inductor high temperature +0 +2 +2 +Inductor_SMD +L_Neosid_Ms85 +Neosid, Ms85, Ms85T, SMD Inductor, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms85.pdf +Neosid Ms85 Ms85T SMD Inductor Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms85T +Neosid, Ms85, Ms85T, SMD Inductor, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms85T.pdf +Neosid Ms85 Ms85T SMD Inductor Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms95 +Neosid,Inductor,Ms95, Ms95a, Ms95T, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms95.pdf +NeosidInductorMs95 Ms95a Ms95T Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms95T +Neosid,Inductor,Ms95, Ms95a, Ms95T, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms95T.pdf +NeosidInductorMs95 Ms95a Ms95T Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_Ms95a +Neosid,Inductor,Ms95, Ms95a, Ms95T, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_Ms95a.pdf +NeosidInductorMs95 Ms95a Ms95T Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE95H +Neosid, Inductor,SM-NE95H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE95H.pdf +Neosid Inductor SM-NE95H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE127 +Neosid, Inductor, SM-NE127, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE127.pdf +Neosid Inductor SM-NE127 Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE127_HandSoldering +Neosid, Inductor, SM-NE127, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE127.pdf +Neosid Inductor SM-NE127 Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-NE150 +Neosid, Inductor, SM-NE150, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMNE150.pdf +Neosid Inductor SM-NE150 Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC0512H +Neosid, Inductor, PIC0512H, Power Inductor, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC0512H.pdf +Neosid Inductor PIC0512H Power Inductor Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC0602H +Neosid, Power Inductor, SM-PIC0602H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC0602H.pdf +Neosid Power Inductor SM-PIC0602H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC0612H +Neosid, Power Inductor, SM-PIC0612H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC0612H.pdf +Neosid Power Inductor SM-PIC0612H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SM-PIC1004H +Neosid, Inductor, SM-PIC1004H, Fixed inductor, SMD, https://neosid.de/import-data/product-pdf/neoFestind_SMPIC1004H.pdf +Neosid Inductor SM-PIC1004H Fixed inductor SMD +0 +2 +2 +Inductor_SMD +L_Neosid_SMS-ME3010 +Neosid, Inductor, SMS-ME3010, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_SMSME3010.pdf +Neosid Inductor SMS-ME3010 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMS-ME3015 +Neosid, Power Inductor, SMS-ME3015, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_SMSME3015.pdf +Neosid Power Inductor SMS-ME3015 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs42 +Neosid, Inductor, SMs42, Fixed inductor, SMD, magneticaly shielded, https://neosid.de/import-data/product-pdf/neoFestind_ma_SMs42.pdf +Neosid Inductor SMs42 Fixed inductor SMD magneticaly shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs50 +Neosid, Inductor, SMs50, Fixed inductor, SMD, magneticaly shielded, https://neosid.de/import-data/product-pdf/neoFestind_ma_SMs50.pdf +Neosid Inductor SMs50 Fixed inductor SMD magneticaly shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs85 +Neosid, Inductor, SMs85, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_ma_SMs85.pdf +Neosid Inductor SMs85 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Neosid_SMs95_SMs95p +Neosid, Inductor, SMs95, Fixed inductor, SMD, magnetically shielded, https://neosid.de/import-data/product-pdf/neoFestind_SMs95SMs95p.pdf +Neosid Inductor SMs95 Fixed inductor SMD magnetically shielded +0 +2 +2 +Inductor_SMD +L_Pulse_PA4320 +Inductor SMD Pulse PA4320 http://productfinder.pulseeng.com/products/datasheets/P787.pdf +Inductor SMD Pulse PA4320 +0 +2 +2 +Inductor_SMD +L_Sagami_CER1242B +Inductor, Sagami, h=4.5mm, http://www.sagami-elec.co.jp/file/CER1242B-CER1257B-CER1277B.pdf +inductor sagami cer12xxb smd +0 +2 +2 +Inductor_SMD +L_Sagami_CER1257B +Inductor, Sagami, h=6.0mm, http://www.sagami-elec.co.jp/file/CER1242B-CER1257B-CER1277B.pdf +inductor sagami cer12xxb smd +0 +2 +2 +Inductor_SMD +L_Sagami_CER1277B +Inductor, Sagami, h=8.0mm, http://www.sagami-elec.co.jp/file/CER1242B-CER1257B-CER1277B.pdf +inductor sagami cer12xxb smd +0 +2 +2 +Inductor_SMD +L_Sagami_CWR1242C +Sagami power inductor, CWR1242C, H=4.5mm (http://www.sagami-elec.co.jp/file/16Car_SMDCwr.pdf) +inductor sagami cwr12xx smd +0 +4 +2 +Inductor_SMD +L_Sagami_CWR1257C +Sagami power inductor, CWR1242C, H=6.0mm (http://www.sagami-elec.co.jp/file/16Car_SMDCwr.pdf) +inductor sagami cwr12xx smd +0 +4 +2 +Inductor_SMD +L_Sagami_CWR1277C +Sagami power inductor, CWR1242C, H=7.7mm (http://www.sagami-elec.co.jp/file/16Car_SMDCwr.pdf) +inductor sagami cwr12xx smd +0 +4 +2 +Inductor_SMD +L_SigTra_SC3316F +http://www.signaltransformer.com/sites/all/pdf/smd/P080_SC3316F.pdf +Choke +0 +2 +2 +Inductor_SMD +L_Sumida_CDMC6D28_7.25x6.5mm +SMD Power Inductor (http://products.sumida.com/products/pdf/CDMC6D28.pdf) +Inductor Sumida SMD CDMC6D28 +0 +2 +2 +Inductor_SMD +L_Sunlord_MWSA0518_5.4x5.2mm +Inductor, Sunlord, MWSA0518, 5.4mmx5.2mm +inductor Sunlord smd +0 +2 +2 +Inductor_SMD +L_TDK_NLV25_2.5x2.0mm +TDK NLV25, 2.5x2.0x1.8mm, https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_standard_nlv25-ef_en.pdf +tdk nlv25 nlcv25 nlfv25 +0 +2 +2 +Inductor_SMD +L_TDK_NLV32_3.2x2.5mm +TDK NLV32, 3.2x2.5x2.2mm, https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_standard_nlv32-ef_en.pdf +tdk nlv32 nlcv32 nlfv32 +0 +2 +2 +Inductor_SMD +L_TDK_SLF6025 +Inductor, TDK, SLF6025, 6.0mmx6.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf6025_en.pdf) +Inductor TDK_SLF6025 +0 +2 +2 +Inductor_SMD +L_TDK_SLF6028 +Inductor, TDK, SLF6028, 6.0mmx6.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf6028_en.pdf) +Inductor TDK_SLF6028 +0 +2 +2 +Inductor_SMD +L_TDK_SLF6045 +Inductor, TDK, SLF6045, 6.0mmx6.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf6045_en.pdf) +Inductor TDK_SLF6045 +0 +2 +2 +Inductor_SMD +L_TDK_SLF7032 +Inductor, TDK, SLF7032, 7.0mmx7.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf7032_en.pdf) +Inductor TDK_SLF7032 +0 +2 +2 +Inductor_SMD +L_TDK_SLF7045 +Inductor, TDK, SLF7045, 7.0mmx7.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf7045_en.pdf) +Inductor TDK_SLF7045 +0 +2 +2 +Inductor_SMD +L_TDK_SLF7055 +Inductor, TDK, SLF7055, 7.0mmx7.0mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/document/catalog/smd/inductor_commercial_power_slf7055_en.pdf) +Inductor TDK_SLF7055 +0 +2 +2 +Inductor_SMD +L_TDK_SLF10145 +Inductor, TDK, SLF10145, 10.1mmx10.1mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_automotive_power_slf10145-h_en.pdf) +Inductor TDK_SLF10145 +0 +2 +2 +Inductor_SMD +L_TDK_SLF10165 +Inductor, TDK, SLF10165, 10.1mmx10.1mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_power_slf10165_en.pdf) +Inductor TDK_SLF10165 +0 +2 +2 +Inductor_SMD +L_TDK_SLF12555 +Inductor, TDK, SLF12555, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_commercial_power_slf12555_en.pdf) +Inductor SLF12555 +0 +2 +2 +Inductor_SMD +L_TDK_SLF12565 +Inductor, TDK, SLF12565, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_automotive_power_slf12565-h_en.pdf) +Inductor SLF12565 +0 +2 +2 +Inductor_SMD +L_TDK_SLF12575 +Inductor, TDK, SLF12575, 12.5mmx12.5mm (Script generated with StandardBox.py) (https://product.tdk.com/info/en/catalog/datasheets/inductor_automotive_power_slf12575-h_en.pdf) +Inductor SLF12575 +0 +2 +2 +Inductor_SMD +L_TDK_VLF10040 +Inductor,TDK, TDK-VLP-8040, 8.6mmx8.6mm +inductor TDK VLP smd VLF10040 +0 +2 +2 +Inductor_SMD +L_TDK_VLP8040 +Inductor,TDK, TDK-VLP-8040, 8.6mmx8.6mm +inductor TDK VLP smd VLP8040 +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-1616 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-1616, 1.6mmx1.6mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-2020 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-2020, 2.0mmx2.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-3030 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-3030, 3.0mmx3.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-4040 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-4040, 4.0mmx4.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_MD-5050 +Inductor, Taiyo Yuden, MD series, Taiyo-Yuden_MD-5050, 5.0mmx5.0mm +inductor taiyo-yuden md smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-20xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-20xx, 2.0mmx2.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-20xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-20xx, 2.0mmx2.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-24xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-24xx, 2.4mmx2.4mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-24xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-24xx, 2.4mmx2.4mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-30xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-30xx, 3.0mmx3.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-30xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-30xx, 3.0mmx3.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-40xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-40xx, 4.0mmx4.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-40xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-40xx, 4.0mmx4.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-50xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-50xx, 4.9mmx4.9mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-50xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-50xx, 4.9mmx4.9mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-60xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-60xx, 6.0mmx6.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-60xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-60xx, 6.0mmx6.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-80xx +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-80xx, 8.0mmx8.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-80xx_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-80xx, 8.0mmx8.0mm +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-10050_9.8x10.0mm +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-10050, 9.8mmx10.0mm, https://ds.yuden.co.jp/TYCOMPAS/or/specSheet?pn=NR10050T1R3N +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_Taiyo-Yuden_NR-10050_9.8x10.0mm_HandSoldering +Inductor, Taiyo Yuden, NR series, Taiyo-Yuden_NR-10050, 9.8mmx10.0mm, https://ds.yuden.co.jp/TYCOMPAS/or/specSheet?pn=NR10050T1R3N +inductor taiyo-yuden nr smd +0 +2 +2 +Inductor_SMD +L_TracoPower_TCK-047_5.2x5.8mm +Inductor, Traco, TCK-047, 5.2x5.8mm, https://www.tracopower.com/products/tck047.pdf +inductor smd traco +0 +2 +2 +Inductor_SMD +L_TracoPower_TCK-141 +Choke, SMD, 4.0x4.0mm 2.1mm height, https://www.tracopower.com/products/tck141.pdf +Choke SMD +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-1212 +Inductor, Vishay, IHLP series, 3.0mmx3.0mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-1616 +Inductor, Vishay, IHLP series, 4.1mmx4.1mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-2020 +Inductor, Vishay, IHLP series, 5.1mmx5.1mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-2525 +Inductor, Vishay, IHLP series, 6.3mmx6.3mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-4040 +Inductor, Vishay, IHLP series, 10.2mmx10.2mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-5050 +Inductor, Vishay, IHLP series, 12.7mmx12.7mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHLP-6767 +Inductor, Vishay, IHLP series, 17.0mmx17.0mm +inductor vishay ihlp smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-3825 +Inductor, Vishay, Vishay_IHSM-3825, http://www.vishay.com/docs/34018/ihsm3825.pdf, 11.2mmx6.3mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-4825 +Inductor, Vishay, Vishay_IHSM-4825, http://www.vishay.com/docs/34019/ihsm4825.pdf, 13.7mmx6.3mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-5832 +Inductor, Vishay, Vishay_IHSM-5832, http://www.vishay.com/docs/34020/ihsm5832.pdf, 16.3mmx8.1mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Vishay_IHSM-7832 +Inductor, Vishay, Vishay_IHSM-7832, http://www.vishay.com/docs/34021/ihsm7832.pdf, 19.8mmx8.1mm +inductor vishay icsm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1030 +Inductor, Wuerth Elektronik, Wuerth_HCI-1030, 10.6mmx10.6mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1040 +Inductor, Wuerth Elektronik, Wuerth_HCI-1040, 10.2mmx10.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1050 +Inductor, Wuerth Elektronik, Wuerth_HCI-1050, 10.2mmx10.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1335 +Inductor, Wuerth Elektronik, Wuerth_HCI-1335, 12.8mmx12.8mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1350 +Inductor, Wuerth Elektronik, Wuerth_HCI-1350, 12.8mmx12.8mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1365 +Inductor, Wuerth Elektronik, Wuerth_HCI-1365, 12.8mmx12.8mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-1890 +Inductor, Wuerth Elektronik, Wuerth_HCI-1890, 18.2mmx18.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-2212 +Inductor, Wuerth Elektronik, Wuerth_HCI-2212, 22.5mmx22.0mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-5040 +Inductor, Wuerth Elektronik, Wuerth_HCI-5040, 5.5mmx5.2mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-7030 +Inductor, Wuerth Elektronik, Wuerth_HCI-7030, 6.9mmx6.9mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-7040 +Inductor, Wuerth Elektronik, Wuerth_HCI-7040, 6.9mmx6.9mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCI-7050 +Inductor, Wuerth Elektronik, Wuerth_HCI-7050, 6.9mmx6.9mm +inductor Wuerth hci smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1050 +Inductor, Wuerth Elektronik, Wuerth_HCM-1050, 10.2mmx7.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1052 +Inductor, Wuerth Elektronik, Wuerth_HCM-1052, 10.5mmx10.3mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1070 +Inductor, Wuerth Elektronik, Wuerth_HCM-1070, 10.1mmx7.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1078 +Inductor, Wuerth Elektronik, Wuerth_HCM-1078, 9.4mmx6.2mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1190 +Inductor, Wuerth Elektronik, Wuerth_HCM-1190, 10.5mmx11.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1240 +Inductor, Wuerth Elektronik, Wuerth_HCM-1240, 10.0mmx11.8mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1350 +Inductor, Wuerth Elektronik, Wuerth_HCM-1350, 13.5mmx13.3mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-1390 +Inductor, Wuerth Elektronik, Wuerth_HCM-1390, 12.5mmx13.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-7050 +Inductor, Wuerth Elektronik, Wuerth_HCM-7050, 7.2mmx7.0mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_HCM-7070 +Inductor, Wuerth Elektronik, Wuerth_HCM-7070, 7.4mmx7.2mm +inductor Wuerth hcm smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-1610 +Inductor, Wuerth Elektronik, Wuerth_MAPI-1610, 1.6mmx1.6mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2010 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2010, 2.0mmx1.6mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2506 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2506, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2508 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2508, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2510 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2510, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-2512 +Inductor, Wuerth Elektronik, Wuerth_MAPI-2512, 2.5mmx2.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3010 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3010, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3012 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3012, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3015 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3015, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-3020 +Inductor, Wuerth Elektronik, Wuerth_MAPI-3020, 3.0mmx3.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-4020 +Inductor, Wuerth Elektronik, Wuerth_MAPI-4020, 4.0mmx4.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_MAPI-4030 +Inductor, Wuerth Elektronik, Wuerth_MAPI-4030, 4.0mmx4.0mm +inductor Wuerth smd +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-DD-Typ-L-Typ-XL-Typ-XXL +Shielded Coupled Inductor, Wuerth Elektronik, WE-DD, SMD, Typ L, Typ XL, Typ XXL, https://katalog.we-online.com/pbs/datasheet/744874001.pdf +Choke Coupled Double Inductor SMD Wuerth WE-DD TypL TypXL TypXXL +0 +4 +4 +Inductor_SMD +L_Wuerth_WE-DD-Typ-M-Typ-S +Shielded Coupled Inductor, Wuerth Elektronik, WE-DD, SMD, Typ M, Typ S, https://katalog.we-online.com/pbs/datasheet/744878001.pdf, https://katalog.we-online.de/pbs/datasheet/744877001.pdf +Choke Coupled Double Inductor SMD Wuerth WE-DD TypM TypS +0 +4 +4 +Inductor_SMD +L_Wuerth_WE-GF-1210 +Unshielded Inductor, Wuerth Elektronik, WE-GF, SMD, 1210, https://www.we-online.de/katalog/datasheet/74476401.pdf +Unshielded Inductor WE-GF 1210 Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-7345 +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMD, 7345, https://katalog.we-online.com/pbs/datasheet/744777001.pdf +Choke Shielded Power Inductor WE-PD 7345 Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-LS +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMD, Typ LS, https://katalog.we-online.com/pbs/datasheet/7447715906.pdf +Choke Shielded Power Inductor WE-PD TypLS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-LS_Handsoldering +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMD, Typ LS, Handsoldering, https://katalog.we-online.com/pbs/datasheet/7447715906.pdf +Choke Shielded Power Inductor WE-PD TypLS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-M-Typ-S +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMT, Typ M, Typ S, https://katalog.we-online.com/pbs/datasheet/744778005.pdf +Choke Shielded Power Inductor WE-PD TypM TypS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD-Typ-M-Typ-S_Handsoldering +Shielded Power Inductor, Wuerth Elektronik, WE-PD, SMT, Typ M, Typ S, Handsoldering, https://katalog.we-online.com/pbs/datasheet/744778005.pdf +Choke Shielded Power Inductor WE-PD TypM TypS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD2-Typ-L +Power Inductor, Wuerth Elektronik, WE-PD2, SMD, Typ L, , https://katalog.we-online.com/pbs/datasheet/74477510.pdf +Choke Power Inductor WE-PD2 TypL Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD2-Typ-MS +Power Inductor, Wuerth Elektronik, WE-PD2, SMD, Typ MS, https://katalog.we-online.com/pbs/datasheet/744774022.pdf +Choke Power Inductor WE-PD2 TypMS Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD2-Typ-XL +Power Inductor, Wuerth Elektronik, WE-PD2, SMT, Typ XL, https://katalog.we-online.com/pbs/datasheet/744776012.pdf +Choke Power Inductor WE-PD2 TypXL Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PD4-Typ-X +Power Inductor, Wuerth Elektronik, WE-PD4, SMT, Typ X, https://katalog.we-online.de/pbs/datasheet/74458001.pdf +Choke Power Inductor WE-PD4 TypX Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PDF +Shielded Power Inductor, Wuerth Elektronik, WE-PDF, SMD, https://katalog.we-online.de/pbs/datasheet/7447797022.pdf +Choke Shielded Power Inductor WE-PDF Wuerth +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-PDF_Handsoldering +Shielded Power Inductor, Wuerth Elektronik, WE-PDF, SMD, Handsoldering, https://katalog.we-online.de/pbs/datasheet/7447797022.pdf +Choke Shielded Power Inductor WE-PDF Wuerth Handsoldering +0 +2 +2 +Inductor_SMD +L_Wuerth_WE-TPC-3816 +L_Wuerth_WE-TPC-3816 StepUp generated footprint, http://katalog.we-online.de/pbs/datasheet/7440310047.pdf +wurth wuerth smd inductor +0 +2 +2 +Inductor_THT +Choke_EPCOS_B82722A +Current-Compensated Ring Core Double Chokes, EPCOS, B82722A, 22.3mmx22.7mm, https://en.tdk.eu/inf/30/db/ind_2008/b82722a_j.pdf +chokes epcos tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN102-04-14.0x14.0mm +Current-compensated Chokes, Schaffner, RN102-04, 14.0mmx14.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN112-04-17.7x17.1mm +Current-compensated Chokes, Schaffner, RN112-04, 17.7mmx17.1mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN114-04-22.5x21.5mm +Current-compensated Chokes, Schaffner, RN114-04, 22.5mmx21.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN116-04-22.5x21.5mm +Current-compensated Chokes, Schaffner, RN116-04, 22.5mmx21.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN122-04-28.0x27.0mm +Current-compensated Chokes, Schaffner, RN122-04, 28.0mmx27.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN142-04-33.1x32.5mm +Current-compensated Chokes, Schaffner, RN142-04, 33.1mmx32.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN143-04-33.1x32.5mm +Current-compensated Chokes, Schaffner, RN143-04, 33.1mmx32.5mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN152-04-43.0x41.8mm +Current-compensated Chokes, Schaffner, RN152-04, 43.0mmx41.8mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN202-04-8.8x18.2mm +Current-compensated Chokes, Schaffner, RN202-04, 8.8mmx18.2mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN204-04-9.0x14.0mm +Current-compensated Chokes, Schaffner, RN204-04, 9.0mmx14.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN212-04-12.5x18.0mm +Current-compensated Chokes, Schaffner, RN212-04, 12.5mmx18.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN214-04-15.5x23.0mm +Current-compensated Chokes, Schaffner, RN214-04, 15.5mmx23.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN216-04-15.5x23.0mm +Current-compensated Chokes, Schaffner, RN216-04, 15.5mmx23.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN218-04-12.5x18.0mm +Current-compensated Chokes, Schaffner, RN218-04, 12.5mmx18.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN222-04-18.0x31.0mm +Current-compensated Chokes, Schaffner, RN222-04, 18.0mmx31.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN232-04-18.0x31.0mm +Current-compensated Chokes, Schaffner, RN232-04, 18.0mmx31.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +Choke_Schaffner_RN242-04-18.0x31.0mm +Current-compensated Chokes, Schaffner, RN242-04, 18.0mmx31.0mm https://www.schaffner.com/products/download/product/datasheet/rn-series-common-mode-chokes-new/ +chokes schaffner tht +0 +4 +4 +Inductor_THT +L_Axial_L5.0mm_D3.6mm_P10.00mm_Horizontal_Murata_BL01RN1A2A2 +Inductor, Murata BL01RN1A2A2, Axial, Horizontal, pin pitch=10.00mm, length*diameter=5*3.6mm, https://www.murata.com/en-global/products/productdetail?partno=BL01RN1A2A2%23 +inductor axial horizontal +0 +2 +2 +Inductor_THT +L_Axial_L5.3mm_D2.2mm_P2.54mm_Vertical_Vishay_IM-1 +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=5.3*2.2mm^2, Vishay, IM-1, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Vertical pin pitch 2.54mm length 5.3mm diameter 2.2mm Vishay IM-1 +0 +2 +2 +Inductor_THT +L_Axial_L5.3mm_D2.2mm_P7.62mm_Horizontal_Vishay_IM-1 +Inductor, Axial series, Axial, Horizontal, pin pitch=7.62mm, , length*diameter=5.3*2.2mm^2, Vishay, IM-1, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Horizontal pin pitch 7.62mm length 5.3mm diameter 2.2mm Vishay IM-1 +0 +2 +2 +Inductor_THT +L_Axial_L5.3mm_D2.2mm_P10.16mm_Horizontal_Vishay_IM-1 +Inductor, Axial series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=5.3*2.2mm^2, Vishay, IM-1, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Horizontal pin pitch 10.16mm length 5.3mm diameter 2.2mm Vishay IM-1 +0 +2 +2 +Inductor_THT +L_Axial_L6.6mm_D2.7mm_P2.54mm_Vertical_Vishay_IM-2 +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=6.6*2.7mm^2, Vishay, IM-2, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Vertical pin pitch 2.54mm length 6.6mm diameter 2.7mm Vishay IM-2 +0 +2 +2 +Inductor_THT +L_Axial_L6.6mm_D2.7mm_P10.16mm_Horizontal_Vishay_IM-2 +Inductor, Axial series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=6.6*2.7mm^2, Vishay, IM-2, http://www.vishay.com/docs/34030/im.pdf +Inductor Axial series Axial Horizontal pin pitch 10.16mm length 6.6mm diameter 2.7mm Vishay IM-2 +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P2.54mm_Vertical_Fastron_MICC +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 2.54mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P5.08mm_Vertical_Fastron_MICC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P10.16mm_Horizontal_Fastron_MICC +Inductor, Axial series, Axial, Horizontal, pin pitch=10.16mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 10.16mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L7.0mm_D3.3mm_P12.70mm_Horizontal_Fastron_MICC +Inductor, Axial series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=7*3.3mm^2, Fastron, MICC, http://www.fastrongroup.com/image-show/70/MICC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 12.7mm length 7mm diameter 3.3mm Fastron MICC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P2.54mm_Vertical_Fastron_SMCC +Inductor, Axial series, Axial, Vertical, pin pitch=2.54mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Vertical pin pitch 2.54mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P5.08mm_Vertical_Fastron_SMCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P12.70mm_Horizontal_Fastron_SMCC +Inductor, Axial series, Axial, Horizontal, pin pitch=12.7mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Horizontal pin pitch 12.7mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L9.5mm_D4.0mm_P15.24mm_Horizontal_Fastron_SMCC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=9.5*4mm^2, Fastron, SMCC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_SMCC_NEU.pdf, http://cdn-reichelt.de/documents/datenblatt/B400/LEADEDINDUCTORS.pdf +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 9.5mm diameter 4mm Fastron SMCC +0 +2 +2 +Inductor_THT +L_Axial_L11.0mm_D4.5mm_P5.08mm_Vertical_Fastron_MECC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=11*4.5mm^2, Fastron, MECC, http://www.fastrongroup.com/image-show/21/MECC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 11mm diameter 4.5mm Fastron MECC +0 +2 +2 +Inductor_THT +L_Axial_L11.0mm_D4.5mm_P7.62mm_Vertical_Fastron_MECC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=11*4.5mm^2, Fastron, MECC, http://www.fastrongroup.com/image-show/21/MECC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 11mm diameter 4.5mm Fastron MECC +0 +2 +2 +Inductor_THT +L_Axial_L11.0mm_D4.5mm_P15.24mm_Horizontal_Fastron_MECC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=11*4.5mm^2, Fastron, MECC, http://www.fastrongroup.com/image-show/21/MECC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 11mm diameter 4.5mm Fastron MECC +0 +2 +2 +Inductor_THT +L_Axial_L12.0mm_D5.0mm_P5.08mm_Vertical_Fastron_MISC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=12*5mm^2, Fastron, MISC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MISC.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 12mm diameter 5mm Fastron MISC +0 +2 +2 +Inductor_THT +L_Axial_L12.0mm_D5.0mm_P7.62mm_Vertical_Fastron_MISC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=12*5mm^2, Fastron, MISC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MISC.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 12mm diameter 5mm Fastron MISC +0 +2 +2 +Inductor_THT +L_Axial_L12.0mm_D5.0mm_P15.24mm_Horizontal_Fastron_MISC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=12*5mm^2, Fastron, MISC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MISC.pdf +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 12mm diameter 5mm Fastron MISC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P5.08mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P7.62mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P20.32mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L12.8mm_D5.8mm_P25.40mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=12.8*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 12.8mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L13.0mm_D4.5mm_P5.08mm_Vertical_Fastron_HCCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=13*4.5mm^2, Fastron, HCCC, http://www.fastrongroup.com/image-show/19/HCCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 13mm diameter 4.5mm Fastron HCCC +0 +2 +2 +Inductor_THT +L_Axial_L13.0mm_D4.5mm_P7.62mm_Vertical_Fastron_HCCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=13*4.5mm^2, Fastron, HCCC, http://www.fastrongroup.com/image-show/19/HCCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 13mm diameter 4.5mm Fastron HCCC +0 +2 +2 +Inductor_THT +L_Axial_L13.0mm_D4.5mm_P15.24mm_Horizontal_Fastron_HCCC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=13*4.5mm^2, Fastron, HCCC, http://www.fastrongroup.com/image-show/19/HCCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 13mm diameter 4.5mm Fastron HCCC +0 +2 +2 +Inductor_THT +L_Axial_L14.0mm_D4.5mm_P5.08mm_Vertical_Fastron_LACC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=14*4.5mm^2, Fastron, LACC, http://www.fastrongroup.com/image-show/20/LACC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 14mm diameter 4.5mm Fastron LACC +0 +2 +2 +Inductor_THT +L_Axial_L14.0mm_D4.5mm_P7.62mm_Vertical_Fastron_LACC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=14*4.5mm^2, Fastron, LACC, http://www.fastrongroup.com/image-show/20/LACC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 14mm diameter 4.5mm Fastron LACC +0 +2 +2 +Inductor_THT +L_Axial_L14.0mm_D4.5mm_P15.24mm_Horizontal_Fastron_LACC +Inductor, Axial series, Axial, Horizontal, pin pitch=15.24mm, , length*diameter=14*4.5mm^2, Fastron, LACC, http://www.fastrongroup.com/image-show/20/LACC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 15.24mm length 14mm diameter 4.5mm Fastron LACC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P5.08mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P7.62mm_Vertical_Fastron_HBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P20.32mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L14.5mm_D5.8mm_P25.40mm_Horizontal_Fastron_HBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=14.5*5.8mm^2, Fastron, HBCC, http://www.fastrongroup.com/image-show/18/HBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 14.5mm diameter 5.8mm Fastron HBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P5.08mm_Vertical_Fastron_VHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P7.62mm_Vertical_Fastron_VHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P20.32mm_Horizontal_Fastron_VHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D6.3mm_P25.40mm_Horizontal_Fastron_VHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=16*6.3mm^2, Fastron, VHBCC, http://www.fastrongroup.com/image-show/25/VHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 16mm diameter 6.3mm Fastron VHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P5.08mm_Vertical_Fastron_XHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 5.08mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P7.62mm_Vertical_Fastron_XHBCC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Vertical pin pitch 7.62mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P20.32mm_Horizontal_Fastron_XHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D7.5mm_P25.40mm_Horizontal_Fastron_XHBCC +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=16*7.5mm^2, Fastron, XHBCC, http://www.fastrongroup.com/image-show/26/XHBCC.pdf?type=Complete-DataSheet&productType=series +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 16mm diameter 7.5mm Fastron XHBCC +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D9.5mm_P5.08mm_Vertical_Vishay_IM-10-37 +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=16*9.5mm^2, Vishay, IM-10-37, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 16mm diameter 9.5mm Vishay IM-10-37 +0 +2 +2 +Inductor_THT +L_Axial_L16.0mm_D9.5mm_P20.32mm_Horizontal_Vishay_IM-10-37 +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=16*9.5mm^2, Vishay, IM-10-37, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 16mm diameter 9.5mm Vishay IM-10-37 +0 +2 +2 +Inductor_THT +L_Axial_L17.5mm_D12.0mm_P7.62mm_Vertical_Vishay_IM-10-46 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=17.5*12mm^2, Vishay, IM-10-46, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 17.5mm diameter 12mm Vishay IM-10-46 +0 +2 +2 +Inductor_THT +L_Axial_L17.5mm_D12.0mm_P20.32mm_Horizontal_Vishay_IM-10-46 +Inductor, Axial series, Axial, Horizontal, pin pitch=20.32mm, , length*diameter=17.5*12mm^2, Vishay, IM-10-46, http://www.vishay.com/docs/34030/im10.pdf +Inductor Axial series Axial Horizontal pin pitch 20.32mm length 17.5mm diameter 12mm Vishay IM-10-46 +0 +2 +2 +Inductor_THT +L_Axial_L20.0mm_D8.0mm_P5.08mm_Vertical +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=20*8mm^2 +Inductor Axial series Axial Vertical pin pitch 5.08mm length 20mm diameter 8mm +0 +2 +2 +Inductor_THT +L_Axial_L20.0mm_D8.0mm_P7.62mm_Vertical +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=20*8mm^2 +Inductor Axial series Axial Vertical pin pitch 7.62mm length 20mm diameter 8mm +0 +2 +2 +Inductor_THT +L_Axial_L20.0mm_D8.0mm_P25.40mm_Horizontal +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=20*8mm^2 +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 20mm diameter 8mm +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.1mm_P7.62mm_Vertical_Vishay_IHA-101 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=20.32*12.07mm^2, Vishay, IHA-101, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 20.32mm diameter 12.07mm Vishay IHA-101 +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.1mm_P28.50mm_Horizontal_Vishay_IHA-101 +Inductor, Axial series, Axial, Horizontal, pin pitch=28.5mm, , length*diameter=20.32*12.07mm^2, Vishay, IHA-101, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 28.5mm length 20.32mm diameter 12.07mm Vishay IHA-101 +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.7mm_P7.62mm_Vertical_Vishay_IHA-201 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=20.32*12.7mm^2, Vishay, IHA-201, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 20.32mm diameter 12.7mm Vishay IHA-201 +0 +2 +2 +Inductor_THT +L_Axial_L20.3mm_D12.7mm_P25.40mm_Horizontal_Vishay_IHA-201 +Inductor, Axial series, Axial, Horizontal, pin pitch=25.4mm, , length*diameter=20.32*12.7mm^2, Vishay, IHA-201, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 25.4mm length 20.32mm diameter 12.7mm Vishay IHA-201 +0 +2 +2 +Inductor_THT +L_Axial_L23.4mm_D12.7mm_P7.62mm_Vertical_Vishay_IHA-203 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=23.37*12.7mm^2, Vishay, IHA-203, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 23.37mm diameter 12.7mm Vishay IHA-203 +0 +2 +2 +Inductor_THT +L_Axial_L23.4mm_D12.7mm_P32.00mm_Horizontal_Vishay_IHA-203 +Inductor, Axial series, Axial, Horizontal, pin pitch=32mm, , length*diameter=23.37*12.7mm^2, Vishay, IHA-203, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 32mm length 23.37mm diameter 12.7mm Vishay IHA-203 +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.1mm_P5.08mm_Vertical_Vishay_IM-10-28 +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=24*7.1mm^2, Vishay, IM-10-28, http://www.vishay.com/docs/34035/im10.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 24mm diameter 7.1mm Vishay IM-10-28 +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.1mm_P30.48mm_Horizontal_Vishay_IM-10-28 +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=24*7.1mm^2, Vishay, IM-10-28, http://www.vishay.com/docs/34035/im10.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 24mm diameter 7.1mm Vishay IM-10-28 +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.5mm_P5.08mm_Vertical_Fastron_MESC +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=24*7.5mm^2, Fastron, MESC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MESC.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 24mm diameter 7.5mm Fastron MESC +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.5mm_P7.62mm_Vertical_Fastron_MESC +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=24*7.5mm^2, Fastron, MESC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MESC.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 24mm diameter 7.5mm Fastron MESC +0 +2 +2 +Inductor_THT +L_Axial_L24.0mm_D7.5mm_P27.94mm_Horizontal_Fastron_MESC +Inductor, Axial series, Axial, Horizontal, pin pitch=27.94mm, , length*diameter=24*7.5mm^2, Fastron, MESC, http://cdn-reichelt.de/documents/datenblatt/B400/DS_MESC.pdf +Inductor Axial series Axial Horizontal pin pitch 27.94mm length 24mm diameter 7.5mm Fastron MESC +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D9.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=26*9mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 26mm diameter 9mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D9.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26*9mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26mm diameter 9mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D9.0mm_P30.48mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=26*9mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 26mm diameter 9mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D10.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=26*10mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 26mm diameter 10mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D10.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26*10mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26mm diameter 10mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D10.0mm_P30.48mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=26*10mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 26mm diameter 10mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D11.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=26*11mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 26mm diameter 11mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D11.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26*11mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26mm diameter 11mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.0mm_D11.0mm_P30.48mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=30.48mm, , length*diameter=26*11mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 30.48mm length 26mm diameter 11mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D12.1mm_P7.62mm_Vertical_Vishay_IHA-103 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26.67*12.07mm^2, Vishay, IHA-103, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26.67mm diameter 12.07mm Vishay IHA-103 +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D12.1mm_P35.00mm_Horizontal_Vishay_IHA-103 +Inductor, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=26.67*12.07mm^2, Vishay, IHA-103, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 35mm length 26.67mm diameter 12.07mm Vishay IHA-103 +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D14.0mm_P7.62mm_Vertical_Vishay_IHA-104 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=26.67*13.97mm^2, Vishay, IHA-104, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 26.67mm diameter 13.97mm Vishay IHA-104 +0 +2 +2 +Inductor_THT +L_Axial_L26.7mm_D14.0mm_P35.00mm_Horizontal_Vishay_IHA-104 +Inductor, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=26.67*13.97mm^2, Vishay, IHA-104, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 35mm length 26.67mm diameter 13.97mm Vishay IHA-104 +0 +2 +2 +Inductor_THT +L_Axial_L29.9mm_D14.0mm_P7.62mm_Vertical_Vishay_IHA-105 +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=29.85*13.97mm^2, Vishay, IHA-105, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 29.85mm diameter 13.97mm Vishay IHA-105 +0 +2 +2 +Inductor_THT +L_Axial_L29.9mm_D14.0mm_P38.00mm_Horizontal_Vishay_IHA-105 +Inductor, Axial series, Axial, Horizontal, pin pitch=38mm, , length*diameter=29.85*13.97mm^2, Vishay, IHA-105, http://www.vishay.com/docs/34014/iha.pdf +Inductor Axial series Axial Horizontal pin pitch 38mm length 29.85mm diameter 13.97mm Vishay IHA-105 +0 +2 +2 +Inductor_THT +L_Axial_L30.0mm_D8.0mm_P5.08mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=5.08mm, , length*diameter=30*8mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 5.08mm length 30mm diameter 8mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L30.0mm_D8.0mm_P7.62mm_Vertical_Fastron_77A +Inductor, Axial series, Axial, Vertical, pin pitch=7.62mm, , length*diameter=30*8mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Vertical pin pitch 7.62mm length 30mm diameter 8mm Fastron 77A +0 +2 +2 +Inductor_THT +L_Axial_L30.0mm_D8.0mm_P35.56mm_Horizontal_Fastron_77A +Inductor, Axial series, Axial, Horizontal, pin pitch=35.56mm, , length*diameter=30*8mm^2, Fastron, 77A, http://cdn-reichelt.de/documents/datenblatt/B400/DS_77A.pdf +Inductor Axial series Axial Horizontal pin pitch 35.56mm length 30mm diameter 8mm Fastron 77A +0 +2 +2 +Inductor_THT +L_CommonMode_Toroid_Vertical_L19.3mm_W10.8mm_Px6.35mm_Py15.24mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=6.35*15.24mm^2, , length*width=19.304*10.795mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 6.35*15.24mm^2 length 19.304mm width 10.795mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L21.0mm_W10.0mm_Px5.08mm_Py12.70mm_muRATA_5100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=5.08*12.70mm^2, , length*width=21*10mm^2, muRATA, 5100, http://www.murata-ps.com/data/magnetics/kmp_5100.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 5.08*12.70mm^2 length 21mm width 10mm muRATA 5100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L24.0mm_W16.3mm_Px10.16mm_Py20.32mm_muRATA_5200 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=10.16*20.32mm^2, , length*width=24*16.3mm^2, muRATA, 5200, http://www.murata-ps.com/data/magnetics/kmp_5200.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 10.16*20.32mm^2 length 24mm width 16.3mm muRATA 5200 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L30.5mm_W15.2mm_Px10.16mm_Py20.32mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=10.16*20.32mm^2, , length*width=30.479999999999997*15.239999999999998mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 10.16*20.32mm^2 length 30.479999999999997mm width 15.239999999999998mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L34.3mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=34.29*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 34.29mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L36.8mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=36.83*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 36.83mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L38.1mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=38.099999999999994*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 38.099999999999994mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L39.4mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=39.37*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 39.37mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L41.9mm_W20.3mm_Px15.24mm_Py22.86mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=15.24*22.86mm^2, , length*width=41.91*20.32mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 15.24*22.86mm^2 length 41.91mm width 20.32mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Toroid_Vertical_L43.2mm_W22.9mm_Px17.78mm_Py30.48mm_Bourns_8100 +L_CommonMode_Toroid, Vertical series, Radial, pin pitch=17.78*30.48mm^2, , length*width=43.18*22.86mm^2, Bourns, 8100, http://datasheet.octopart.com/8120-RC-Bourns-datasheet-10228452.pdf +L_CommonMode_Toroid Vertical series Radial pin pitch 17.78*30.48mm^2 length 43.18mm width 22.86mm Bourns 8100 +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-L +Wuerth, WE-CMB, Bauform L, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-M +Wuerth, WE-CMB, Bauform M, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-S +Wuerth, WE-CMB, Bauform S, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-XL +Wuerth, WE-CMB, Bauform XL, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-XS +Wuerth, WE-CMB, Bauform XS, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_CommonMode_Wuerth_WE-CMB-XXL +Wuerth, WE-CMB, Bauform XXL, +CommonModeChoke Gleichtaktdrossel +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM120 +Lodestone Pacific, 30.48mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM160 +Lodestone Pacific, 40.64mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM254 +Lodestone Pacific, 64.51mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM280 +Lodestone Pacific, 71.12mm diameter vertical toroid mount, 16AWG/1.27mm holes, http://www.lodestonepacific.com/CatKpdf/VTM_Series.pdf +vertical inductor toroid mount +0 +4 +4 +Inductor_THT +L_Mount_Lodestone_VTM950-6 +Lodestone Pacific, vertical toroid mount, 11x19mm, 6 pins, http://www.lodestonepacific.com/CatKpdf/VTM950-6.pdf +vertical inductor toroid mount +0 +6 +6 +Inductor_THT +L_Radial_D6.0mm_P4.00mm +Inductor, Radial series, Radial, pin pitch=4.00mm, , diameter=6.0mm, http://www.abracon.com/Magnetics/radial/AIUR-07.pdf +Inductor Radial series Radial pin pitch 4.00mm diameter 6.0mm +0 +2 +2 +Inductor_THT +L_Radial_D7.0mm_P3.00mm +Inductor, Radial series, Radial, pin pitch=3.00mm, , diameter=7mm, http://www.abracon.com/Magnetics/radial/AIUR-16.pdf +Inductor Radial series Radial pin pitch 3.00mm diameter 7mm +0 +2 +2 +Inductor_THT +L_Radial_D7.2mm_P3.00mm_MuRATA_1700 +Inductor, Radial series, Radial, pin pitch=3.00mm, , diameter=7.2mm, MuRATA, 1700, http://www.murata-ps.com/data/magnetics/kmp_1700.pdf +Inductor Radial series Radial pin pitch 3.00mm diameter 7.2mm MuRATA 1700 +0 +2 +2 +Inductor_THT +L_Radial_D7.5mm_P3.50mm_Fastron_07P +Inductor, Radial series, Radial, pin pitch=3.50mm, , diameter=7.5mm, Fastron, 07P, http://www.fastrongroup.com/image-show/39/07P.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 3.50mm diameter 7.5mm Fastron 07P +0 +2 +2 +Inductor_THT +L_Radial_D7.5mm_P5.00mm_Fastron_07P +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=7.5mm, Fastron, 07P, http://www.fastrongroup.com/image-show/39/07P.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 7.5mm Fastron 07P +0 +2 +2 +Inductor_THT +L_Radial_D7.8mm_P5.00mm_Fastron_07HCP +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=7.8mm, Fastron, 07HCP, http://www.abracon.com/Magnetics/radial/AISR875.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 7.8mm Fastron 07HCP +0 +2 +2 +Inductor_THT +L_Radial_D8.7mm_P5.00mm_Fastron_07HCP +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=8.7mm, Fastron, 07HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_07HCP.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 8.7mm Fastron 07HCP +0 +2 +2 +Inductor_THT +L_Radial_D9.5mm_P5.00mm_Fastron_07HVP +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=9.5mm, Fastron, 07HVP, http://www.fastrongroup.com/image-show/107/07HVP%2007HVP_T.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 9.5mm Fastron 07HVP +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Fastron_07M +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Fastron, 07M, http://www.fastrongroup.com/image-show/37/07M.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 10mm Fastron 07M +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Fastron_07P +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Fastron, 07P, http://www.fastrongroup.com/image-show/37/07M.pdf?type=Complete-DataSheet&productType=series +Inductor Radial series Radial pin pitch 5.00mm diameter 10mm Fastron 07P +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Neosid_SD12_style3 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10.0mm, Neosid, SD12, style3, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 10.0mm Neosid SD12 style3 +0 +2 +2 +Inductor_THT +L_Radial_D10.0mm_P5.00mm_Neosid_SD12k_style3 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10.0mm, Neosid, SD12k, style3, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12k.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 10.0mm Neosid SD12k style3 +0 +2 +2 +Inductor_THT +L_Radial_D10.5mm_P4.00x5.00mm_Murata_1200RS +Inductor, Radial, Pitch=4.00x5.00mm, Diameter=10.5mm, Murata 1200RS, http://www.murata-ps.com/data/magnetics/kmp_1200rs.pdf +Inductor Radial Murata 1200RS +0 +4 +2 +Inductor_THT +L_Radial_D10.5mm_P5.00mm_Abacron_AISR-01 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=10.5mm, Abacron, AISR-01, http://www.abracon.com/Magnetics/radial/AISR-01.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 10.5mm Abacron AISR-01 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P5.00mm_Fastron_11P +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=12.0mm, Fastron, 11P, http://cdn-reichelt.de/documents/datenblatt/B400/DS_11P.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 12.0mm Fastron 11P +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P5.00mm_Neosid_SD12_style2 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=12.0mm, Neosid, SD12, style2, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 12.0mm Neosid SD12 style2 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P5.00mm_Neosid_SD12k_style2 +Inductor, Radial series, Radial, pin pitch=5.00mm, , diameter=12.0mm, Neosid, SD12k, style2, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12k.pdf +Inductor Radial series Radial pin pitch 5.00mm diameter 12.0mm Neosid SD12k style2 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P6.00mm_MuRATA_1900R +Inductor, Radial series, Radial, pin pitch=6.00mm, , diameter=12.0mm, MuRATA, 1900R, http://www.murata-ps.com/data/magnetics/kmp_1900r.pdf +Inductor Radial series Radial pin pitch 6.00mm diameter 12.0mm MuRATA 1900R +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P10.00mm_Neosid_SD12_style1 +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=12.0mm, Neosid, SD12, style1, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 12.0mm Neosid SD12 style1 +0 +2 +2 +Inductor_THT +L_Radial_D12.0mm_P10.00mm_Neosid_SD12k_style1 +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=12.0mm, Neosid, SD12k, style1, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd12k.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 12.0mm Neosid SD12k style1 +0 +2 +2 +Inductor_THT +L_Radial_D12.5mm_P7.00mm_Fastron_09HCP +Inductor, Radial series, Radial, pin pitch=7.00mm, , diameter=12.5mm, Fastron, 09HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_09HCP.pdf +Inductor Radial series Radial pin pitch 7.00mm diameter 12.5mm Fastron 09HCP +0 +2 +2 +Inductor_THT +L_Radial_D12.5mm_P9.00mm_Fastron_09HCP +Inductor, Radial series, Radial, pin pitch=9.00mm, , diameter=12.5mm, Fastron, 09HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_09HCP.pdf +Inductor Radial series Radial pin pitch 9.00mm diameter 12.5mm Fastron 09HCP +0 +2 +2 +Inductor_THT +L_Radial_D13.5mm_P7.00mm_Fastron_09HCP +Inductor, Radial series, Radial, pin pitch=7.00mm, , diameter=13.5mm, Fastron, 09HCP, http://cdn-reichelt.de/documents/datenblatt/B400/DS_09HCP.pdf +Inductor Radial series Radial pin pitch 7.00mm diameter 13.5mm Fastron 09HCP +0 +2 +2 +Inductor_THT +L_Radial_D14.2mm_P10.00mm_Neosid_SD14 +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=14.2mm, Neosid, SD14, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd14.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 14.2mm Neosid SD14 +0 +2 +2 +Inductor_THT +L_Radial_D16.8mm_P11.43mm_Vishay_IHB-1 +Inductor, Radial series, Radial, pin pitch=11.43mm, , diameter=16.8mm, Vishay, IHB-1, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 11.43mm diameter 16.8mm Vishay IHB-1 +0 +2 +2 +Inductor_THT +L_Radial_D16.8mm_P12.07mm_Vishay_IHB-1 +Inductor, Radial series, Radial, pin pitch=12.07mm, , diameter=16.8mm, Vishay, IHB-1, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 12.07mm diameter 16.8mm Vishay IHB-1 +0 +2 +2 +Inductor_THT +L_Radial_D16.8mm_P12.70mm_Vishay_IHB-1 +Inductor, Radial series, Radial, pin pitch=12.70mm, , diameter=16.8mm, Vishay, IHB-1, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 12.70mm diameter 16.8mm Vishay IHB-1 +0 +2 +2 +Inductor_THT +L_Radial_D18.0mm_P10.00mm +Inductor, Radial series, Radial, pin pitch=10.00mm, , diameter=18mm, http://www.abracon.com/Magnetics/radial/AIUR-15.pdf +Inductor Radial series Radial pin pitch 10.00mm diameter 18mm +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P14.61mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=14.61mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 14.61mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P15.00mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=15.00mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 15.00mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P15.24mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=15.24mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 15.24mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P15.75mm_Vishay_IHB-2 +Inductor, Radial series, Radial, pin pitch=15.75mm, , diameter=21mm, Vishay, IHB-2, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 15.75mm diameter 21mm Vishay IHB-2 +0 +2 +2 +Inductor_THT +L_Radial_D21.0mm_P19.00mm +Inductor, Radial series, Radial, pin pitch=19.00mm, , diameter=21mm, http://www.abracon.com/Magnetics/radial/AIRD02.pdf +Inductor Radial series Radial pin pitch 19.00mm diameter 21mm +0 +2 +2 +Inductor_THT +L_Radial_D24.0mm_P24.00mm +Inductor, Radial series, Radial, pin pitch=24.00mm, , diameter=24mm +Inductor Radial series Radial pin pitch 24.00mm diameter 24mm +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P22.90mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=22.90mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 22.90mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.10mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.10mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.10mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.40mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.40mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.40mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.70mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.70mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.70mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D24.4mm_P23.90mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=23.90mm, , diameter=24.4mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 23.90mm diameter 24.4mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D27.9mm_P18.29mm_Vishay_IHB-3 +Inductor, Radial series, Radial, pin pitch=18.29mm, , diameter=27.9mm, Vishay, IHB-3, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 18.29mm diameter 27.9mm Vishay IHB-3 +0 +2 +2 +Inductor_THT +L_Radial_D27.9mm_P19.05mm_Vishay_IHB-3 +Inductor, Radial series, Radial, pin pitch=19.05mm, , diameter=27.9mm, Vishay, IHB-3, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 19.05mm diameter 27.9mm Vishay IHB-3 +0 +2 +2 +Inductor_THT +L_Radial_D27.9mm_P20.07mm_Vishay_IHB-3 +Inductor, Radial series, Radial, pin pitch=20.07mm, , diameter=27.9mm, Vishay, IHB-3, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 20.07mm diameter 27.9mm Vishay IHB-3 +0 +2 +2 +Inductor_THT +L_Radial_D28.0mm_P29.20mm +Inductor, Radial series, Radial, pin pitch=29.20mm, , diameter=28mm +Inductor Radial series Radial pin pitch 29.20mm diameter 28mm +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P28.30mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=28.30mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 28.30mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P28.50mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=28.50mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 28.50mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P28.80mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=28.80mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 28.80mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P29.00mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=29.00mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 29.00mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D29.8mm_P29.30mm_muRATA_1400series +Inductor, Radial series, Radial, pin pitch=29.30mm, , diameter=29.8mm, muRATA, 1400series, http://www.murata-ps.com/data/magnetics/kmp_1400.pdf +Inductor Radial series Radial pin pitch 29.30mm diameter 29.8mm muRATA 1400series +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P26.16mm_Vishay_IHB-5 +Inductor, Radial series, Radial, pin pitch=26.16mm, , diameter=40.64mm, Vishay, IHB-5, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 26.16mm diameter 40.64mm Vishay IHB-5 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P27.18mm_Vishay_IHB-4 +Inductor, Radial series, Radial, pin pitch=27.18mm, , diameter=40.64mm, Vishay, IHB-4, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 27.18mm diameter 40.64mm Vishay IHB-4 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P27.94mm_Vishay_IHB-4 +Inductor, Radial series, Radial, pin pitch=27.94mm, , diameter=40.64mm, Vishay, IHB-4, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 27.94mm diameter 40.64mm Vishay IHB-4 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P27.94mm_Vishay_IHB-5 +Inductor, Radial series, Radial, pin pitch=27.94mm, , diameter=40.64mm, Vishay, IHB-5, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 27.94mm diameter 40.64mm Vishay IHB-5 +0 +2 +2 +Inductor_THT +L_Radial_D40.6mm_P28.70mm_Vishay_IHB-5 +Inductor, Radial series, Radial, pin pitch=28.70mm, , diameter=40.64mm, Vishay, IHB-5, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 28.70mm diameter 40.64mm Vishay IHB-5 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P33.27mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=33.27mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 33.27mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P34.29mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=34.29mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 34.29mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P35.81mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=35.81mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 35.81mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P36.32mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=36.32mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 36.32mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_D50.8mm_P38.86mm_Vishay_IHB-6 +Inductor, Radial series, Radial, pin pitch=38.86mm, , diameter=50.8mm, Vishay, IHB-6, http://www.vishay.com/docs/34015/ihb.pdf +Inductor Radial series Radial pin pitch 38.86mm diameter 50.8mm Vishay IHB-6 +0 +2 +2 +Inductor_THT +L_Radial_L7.5mm_W4.6mm_P5.00mm_Neosid_SD75 +Inductor, Radial series, Radial, pin pitch=5.00mm, , length*width=7.5*4.6mm^2, Neosid, SD75, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd75.pdf +Inductor Radial series Radial pin pitch 5.00mm length 7.5mm width 4.6mm Neosid SD75 +0 +2 +2 +Inductor_THT +L_Radial_L8.0mm_W8.0mm_P5.00mm_Neosid_NE-CPB-07E +Inductor, Radial series, Radial, pin pitch=5.00mm, , length*width=8*8mm^2, Neosid, NE-CPB-07E, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB07E.pdf +Inductor Radial series Radial pin pitch 5.00mm length 8mm width 8mm Neosid NE-CPB-07E +0 +2 +2 +Inductor_THT +L_Radial_L8.0mm_W8.0mm_P5.00mm_Neosid_SD8 +Inductor, Radial series, Radial, pin pitch=5.00mm, , length*width=8*8mm^2, Neosid, SD8, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_Sd8.pdf +Inductor Radial series Radial pin pitch 5.00mm length 8mm width 8mm Neosid SD8 +0 +2 +2 +Inductor_THT +L_Radial_L9.1mm_W9.1mm_Px6.35mm_Py6.35mm_Pulse_LP-25 +Inductor, Radial series, Radial, pin pitch=6.35*6.35mm^2, , length*width=9.14*9.14mm^2, Pulse, LP-25, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 6.35*6.35mm^2 length 9.14mm width 9.14mm Pulse LP-25 +0 +2 +2 +Inductor_THT +L_Radial_L10.2mm_W10.2mm_Px7.62mm_Py7.62mm_Pulse_LP-30 +Inductor, Radial series, Radial, pin pitch=7.62*7.62mm^2, , length*width=10.16*10.16mm^2, Pulse, LP-30, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 7.62*7.62mm^2 length 10.16mm width 10.16mm Pulse LP-30 +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.3mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.3mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.3mm +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.5mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.5mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.5mm +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.7mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.7mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.7mm +0 +2 +2 +Inductor_THT +L_Radial_L11.5mm_W11.5mm_Px6.00mm_Py6.00mm_Neosid_NE-CPB-11EN_Drill1.8mm +Inductor, Radial series, Radial, pin pitch=6.00*6.00mm^2, , length*width=11.5*11.5mm^2, Neosid, NE-CPB-11EN, Drill1.8mm, http://www.neosid.de/produktblaetter/neosid_Festinduktivitaet_NE_CPB11EN.pdf +Inductor Radial series Radial pin pitch 6.00*6.00mm^2 length 11.5mm width 11.5mm Neosid NE-CPB-11EN Drill1.8mm +0 +2 +2 +Inductor_THT +L_Radial_L12.6mm_W12.6mm_Px9.52mm_Py9.52mm_Pulse_LP-37 +Inductor, Radial series, Radial, pin pitch=9.52*9.52mm^2, , length*width=12.57*12.57mm^2, Pulse, LP-37, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 9.52*9.52mm^2 length 12.57mm width 12.57mm Pulse LP-37 +0 +2 +2 +Inductor_THT +L_Radial_L16.1mm_W16.1mm_Px7.62mm_Py12.70mm_Pulse_LP-44 +Inductor, Radial series, Radial, pin pitch=7.62*12.70mm^2, , length*width=16.13*16.13mm^2, Pulse, LP-44, http://datasheet.octopart.com/PE-54044NL-Pulse-datasheet-5313493.pdf +Inductor Radial series Radial pin pitch 7.62*12.70mm^2 length 16.13mm width 16.13mm Pulse LP-44 +0 +2 +2 +Inductor_THT +L_SELF1408 +Self Ferrite 14 - 08 +SELF +0 +7 +3 +Inductor_THT +L_SELF1418 +Self Ferrite 14 - 18 +SELF +0 +10 +4 +Inductor_THT +L_Toroid_Horizontal_D3.2mm_P6.40mm_Diameter3-5mm_Amidon-T12 +L_Toroid, Horizontal series, Radial, pin pitch=6.40mm, , diameter=3.175mm, Diameter3-5mm, Amidon-T12 +L_Toroid Horizontal series Radial pin pitch 6.40mm diameter 3.175mm Diameter3-5mm Amidon-T12 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D4.1mm_P8.00mm_Diameter4-5mm_Amidon-T16 +L_Toroid, Horizontal series, Radial, pin pitch=8.00mm, , diameter=4.064mm, Diameter4-5mm, Amidon-T16 +L_Toroid Horizontal series Radial pin pitch 8.00mm diameter 4.064mm Diameter4-5mm Amidon-T16 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D5.1mm_P9.00mm_Diameter6-5mm_Amidon-T20 +L_Toroid, Horizontal series, Radial, pin pitch=9.00mm, , diameter=5.08mm, Diameter6-5mm, Amidon-T20 +L_Toroid Horizontal series Radial pin pitch 9.00mm diameter 5.08mm Diameter6-5mm Amidon-T20 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D6.5mm_P10.00mm_Diameter7-5mm_Amidon-T25 +L_Toroid, Horizontal series, Radial, pin pitch=10.00mm, , diameter=6.476999999999999mm, Diameter7-5mm, Amidon-T25 +L_Toroid Horizontal series Radial pin pitch 10.00mm diameter 6.476999999999999mm Diameter7-5mm Amidon-T25 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D7.8mm_P13.00mm_Diameter9-5mm_Amidon-T30 +L_Toroid, Horizontal series, Radial, pin pitch=13.00mm, , diameter=7.7978mm, Diameter9-5mm, Amidon-T30 +L_Toroid Horizontal series Radial pin pitch 13.00mm diameter 7.7978mm Diameter9-5mm Amidon-T30 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D9.5mm_P15.00mm_Diameter10-5mm_Amidon-T37 +L_Toroid, Horizontal series, Radial, pin pitch=15.00mm, , diameter=9.524999999999999mm, Diameter10-5mm, Amidon-T37 +L_Toroid Horizontal series Radial pin pitch 15.00mm diameter 9.524999999999999mm Diameter10-5mm Amidon-T37 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D11.2mm_P17.00mm_Diameter12-5mm_Amidon-T44 +L_Toroid, Horizontal series, Radial, pin pitch=17.00mm, , diameter=11.176mm, Diameter12-5mm, Amidon-T44 +L_Toroid Horizontal series Radial pin pitch 17.00mm diameter 11.176mm Diameter12-5mm Amidon-T44 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D12.7mm_P20.00mm_Diameter14-5mm_Amidon-T50 +L_Toroid, Horizontal series, Radial, pin pitch=20.00mm, , diameter=12.7mm, Diameter14-5mm, Amidon-T50 +L_Toroid Horizontal series Radial pin pitch 20.00mm diameter 12.7mm Diameter14-5mm Amidon-T50 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D16.8mm_P14.70mm_Vishay_TJ3 +L_Toroid, Horizontal series, Radial, pin pitch=14.70mm, , diameter=16.8mm, Vishay, TJ3, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 14.70mm diameter 16.8mm Vishay TJ3 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D16.8mm_P14.70mm_Vishay_TJ3_BigPads +L_Toroid, Horizontal series, Radial, pin pitch=14.70mm, , diameter=16.8mm, Vishay, TJ3, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 14.70mm diameter 16.8mm Vishay TJ3 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D17.3mm_P15.24mm_Bourns_2000 +L_Toroid, Horizontal series, Radial, pin pitch=15.24mm, , diameter=17.3mm, Bourns, 2000, http://www.bourns.com/docs/Product-Datasheets/2000_series.pdf?sfvrsn=5 +L_Toroid Horizontal series Radial pin pitch 15.24mm diameter 17.3mm Bourns 2000 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D21.8mm_P19.10mm_Bourns_2100 +L_Toroid, Horizontal series, Radial, pin pitch=19.10mm, , diameter=21.8mm, Bourns, 2100, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 19.10mm diameter 21.8mm Bourns 2100 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D21.8mm_P19.60mm_Bourns_2100 +L_Toroid, Horizontal series, Radial, pin pitch=19.60mm, , diameter=21.8mm, Bourns, 2100, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 19.60mm diameter 21.8mm Bourns 2100 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D22.4mm_P19.80mm_Vishay_TJ4 +L_Toroid, Horizontal series, Radial, pin pitch=19.80mm, , diameter=22.4mm, Vishay, TJ4, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 19.80mm diameter 22.4mm Vishay TJ4 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D24.1mm_P21.80mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=21.80mm, , diameter=24.1mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 21.80mm diameter 24.1mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D24.1mm_P23.10mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=23.10mm, , diameter=24.1mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 23.10mm diameter 24.1mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D25.4mm_P22.90mm_Vishay_TJ5 +L_Toroid, Horizontal series, Radial, pin pitch=22.90mm, , diameter=25.4mm, Vishay, TJ5, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 22.90mm diameter 25.4mm Vishay TJ5 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D25.4mm_P22.90mm_Vishay_TJ5_BigPads +L_Toroid, Horizontal series, Radial, pin pitch=22.90mm, , diameter=25.4mm, Vishay, TJ5, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 22.90mm diameter 25.4mm Vishay TJ5 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D26.0mm_P5.08mm +inductor 26mm diameter toroid +SELF INDUCTOR +0 +3 +2 +Inductor_THT +L_Toroid_Horizontal_D28.0mm_P25.10mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=25.10mm, , diameter=28mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 25.10mm diameter 28mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D28.0mm_P26.67mm_Bourns_2200 +L_Toroid, Horizontal series, Radial, pin pitch=26.67mm, , diameter=28mm, Bourns, 2200, http://www.bourns.com/docs/Product-Datasheets/2100_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 26.67mm diameter 28mm Bourns 2200 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D32.5mm_P28.90mm_Bourns_2300 +L_Toroid, Horizontal series, Radial, pin pitch=28.90mm, , diameter=32.5mm, Bourns, 2300, http://www.bourns.com/docs/Product-Datasheets/2300_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 28.90mm diameter 32.5mm Bourns 2300 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D32.5mm_P30.00mm_Bourns_2300 +L_Toroid, Horizontal series, Radial, pin pitch=30.00mm, , diameter=32.5mm, Bourns, 2300, http://www.bourns.com/docs/Product-Datasheets/2300_series.pdf?sfvrsn=3 +L_Toroid Horizontal series Radial pin pitch 30.00mm diameter 32.5mm Bourns 2300 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D35.1mm_P31.00mm_Vishay_TJ6 +L_Toroid, Horizontal series, Radial, pin pitch=31.00mm, , diameter=35.1mm, Vishay, TJ6, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 31.00mm diameter 35.1mm Vishay TJ6 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D40.0mm_P48.26mm +L_Toroid, Horizontal series, Radial, pin pitch=48.26mm, , diameter=40mm +L_Toroid Horizontal series Radial pin pitch 48.26mm diameter 40mm +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D41.9mm_P37.60mm_Vishay_TJ7 +L_Toroid, Horizontal series, Radial, pin pitch=37.60mm, , diameter=41.9mm, Vishay, TJ7, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 37.60mm diameter 41.9mm Vishay TJ7 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D49.3mm_P44.60mm_Vishay_TJ8 +L_Toroid, Horizontal series, Radial, pin pitch=44.60mm, , diameter=49.3mm, Vishay, TJ8, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 44.60mm diameter 49.3mm Vishay TJ8 +0 +2 +2 +Inductor_THT +L_Toroid_Horizontal_D69.1mm_P63.20mm_Vishay_TJ9 +L_Toroid, Horizontal series, Radial, pin pitch=63.20mm, , diameter=69.1mm, Vishay, TJ9, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Horizontal series Radial pin pitch 63.20mm diameter 69.1mm Vishay TJ9 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L10.0mm_W5.0mm_P5.08mm +L_Toroid, Vertical series, Radial, pin pitch=5.08mm, , length*width=10*5mm^2 +L_Toroid Vertical series Radial pin pitch 5.08mm length 10mm width 5mm +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L13.0mm_W6.5mm_P5.60mm +L_Toroid, Vertical series, Radial, pin pitch=5.60mm, , length*width=13*6.5mm^2 +L_Toroid Vertical series Radial pin pitch 5.60mm length 13mm width 6.5mm +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L14.0mm_W5.6mm_P5.30mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=5.30mm, , length*width=14*5.6mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 5.30mm length 14mm width 5.6mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L14.0mm_W6.3mm_P4.57mm_Pulse_A +L_Toroid, Vertical series, Radial, pin pitch=4.57mm, , length*width=13.97*6.35mm^2, Pulse, A, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 4.57mm length 13.97mm width 6.35mm Pulse A +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L14.7mm_W8.6mm_P5.58mm_Pulse_KM-1 +L_Toroid, Vertical series, Radial, pin pitch=5.58mm, , length*width=14.73*8.64mm^2, Pulse, KM-1, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 5.58mm length 14.73mm width 8.64mm Pulse KM-1 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.0mm_W8.0mm_P7.62mm +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=16*8mm^2 +L_Toroid Vertical series Radial pin pitch 7.62mm length 16mm width 8mm +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.3mm_W7.1mm_P7.11mm_Pulse_H +L_Toroid, Vertical series, Radial, pin pitch=7.11mm, , length*width=16.26*7.11mm^2, Pulse, H, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.11mm length 16.26mm width 7.11mm Pulse H +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.4mm_W7.6mm_P6.60mm_Vishay_TJ3 +L_Toroid, Vertical series, Radial, pin pitch=6.60mm, , length*width=16.4*7.6mm^2, Vishay, TJ3, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 6.60mm length 16.4mm width 7.6mm Vishay TJ3 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.5mm_W11.4mm_P7.62mm_Pulse_KM-2 +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=16.51*11.43mm^2, Pulse, KM-2, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.62mm length 16.51mm width 11.43mm Pulse KM-2 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.8mm_W9.2mm_P7.10mm_Vishay_TJ3 +L_Toroid, Vertical series, Radial, pin pitch=7.10mm, , length*width=16.8*9.2mm^2, Vishay, TJ3, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 7.10mm length 16.8mm width 9.2mm Vishay TJ3 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L16.8mm_W9.2mm_P7.10mm_Vishay_TJ3_BigPads +L_Toroid, Vertical series, Radial, pin pitch=7.10mm, , length*width=16.8*9.2mm^2, Vishay, TJ3, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 7.10mm length 16.8mm width 9.2mm Vishay TJ3 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L17.8mm_W8.1mm_P7.62mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=17.8*8.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 7.62mm length 17.8mm width 8.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L17.8mm_W9.7mm_P7.11mm_Pulse_B +L_Toroid, Vertical series, Radial, pin pitch=7.11mm, , length*width=17.78*9.65mm^2, Pulse, B, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.11mm length 17.78mm width 9.65mm Pulse B +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L19.1mm_W8.1mm_P7.10mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=7.10mm, , length*width=19.1*8.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 7.10mm length 19.1mm width 8.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W8.4mm_P8.38mm_Pulse_G +L_Toroid, Vertical series, Radial, pin pitch=8.38mm, , length*width=21.59*8.38mm^2, Pulse, G, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 8.38mm length 21.59mm width 8.38mm Pulse G +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W9.1mm_P8.40mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=8.40mm, , length*width=21.6*9.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 8.40mm length 21.6mm width 9.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W9.5mm_P7.11mm_Pulse_C +L_Toroid, Vertical series, Radial, pin pitch=7.11mm, , length*width=21.59*9.53mm^2, Pulse, C, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.11mm length 21.59mm width 9.53mm Pulse C +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L21.6mm_W11.4mm_P7.62mm_Pulse_KM-3 +L_Toroid, Vertical series, Radial, pin pitch=7.62mm, , length*width=21.59*11.43mm^2, Pulse, KM-3, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 7.62mm length 21.59mm width 11.43mm Pulse KM-3 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L22.4mm_W10.2mm_P7.90mm_Vishay_TJ4 +L_Toroid, Vertical series, Radial, pin pitch=7.90mm, , length*width=22.4*10.2mm^2, Vishay, TJ4, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 7.90mm length 22.4mm width 10.2mm Vishay TJ4 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L24.6mm_W15.5mm_P11.44mm_Pulse_KM-4 +L_Toroid, Vertical series, Radial, pin pitch=11.44mm, , length*width=24.64*15.5mm^2, Pulse, KM-4, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 11.44mm length 24.64mm width 15.5mm Pulse KM-4 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L25.4mm_W14.7mm_P12.20mm_Vishay_TJ5 +L_Toroid, Vertical series, Radial, pin pitch=12.20mm, , length*width=25.4*14.7mm^2, Vishay, TJ5, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 12.20mm length 25.4mm width 14.7mm Vishay TJ5 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L25.4mm_W14.7mm_P12.20mm_Vishay_TJ5_BigPads +L_Toroid, Vertical series, Radial, pin pitch=12.20mm, , length*width=25.4*14.7mm^2, Vishay, TJ5, BigPads, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 12.20mm length 25.4mm width 14.7mm Vishay TJ5 BigPads +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L26.7mm_W14.0mm_P10.16mm_Pulse_D +L_Toroid, Vertical series, Radial, pin pitch=10.16mm, , length*width=26.67*13.97mm^2, Pulse, D, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 10.16mm length 26.67mm width 13.97mm Pulse D +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L28.6mm_W14.3mm_P11.43mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=11.43mm, , length*width=28.6*14.3mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 11.43mm length 28.6mm width 14.3mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L31.8mm_W15.9mm_P13.50mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=13.50mm, , length*width=31.8*15.9mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 13.50mm length 31.8mm width 15.9mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L33.0mm_W17.8mm_P12.70mm_Pulse_KM-5 +L_Toroid, Vertical series, Radial, pin pitch=12.70mm, , length*width=33.02*17.78mm^2, Pulse, KM-5, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 12.70mm length 33.02mm width 17.78mm Pulse KM-5 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L35.1mm_W21.1mm_P18.50mm_Vishay_TJ6 +L_Toroid, Vertical series, Radial, pin pitch=18.50mm, , length*width=35.1*21.1mm^2, Vishay, TJ6, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 18.50mm length 35.1mm width 21.1mm Vishay TJ6 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L35.6mm_W17.8mm_P12.70mm_Pulse_E +L_Toroid, Vertical series, Radial, pin pitch=12.70mm, , length*width=35.56*17.78mm^2, Pulse, E, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 12.70mm length 35.56mm width 17.78mm Pulse E +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L41.9mm_W17.8mm_P12.70mm_Pulse_F +L_Toroid, Vertical series, Radial, pin pitch=12.70mm, , length*width=41.91*17.78mm^2, Pulse, F, http://datasheet.octopart.com/PE-92112KNL-Pulse-datasheet-17853305.pdf +L_Toroid Vertical series Radial pin pitch 12.70mm length 41.91mm width 17.78mm Pulse F +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L41.9mm_W19.1mm_P15.80mm_Vishay_TJ7 +L_Toroid, Vertical series, Radial, pin pitch=15.80mm, , length*width=41.9*19.1mm^2, Vishay, TJ7, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 15.80mm length 41.9mm width 19.1mm Vishay TJ7 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L46.0mm_W19.1mm_P21.80mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=21.80mm, , length*width=46*19.1mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 21.80mm length 46mm width 19.1mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L48.8mm_W25.4mm_P20.80mm_Vishay_TJ8 +L_Toroid, Vertical series, Radial, pin pitch=20.80mm, , length*width=48.8*25.4mm^2, Vishay, TJ8, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 20.80mm length 48.8mm width 25.4mm Vishay TJ8 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L54.0mm_W23.8mm_P20.10mm_Bourns_5700 +L_Toroid, Vertical series, Radial, pin pitch=20.10mm, , length*width=54*23.8mm^2, Bourns, 5700, http://www.bourns.com/docs/Product-Datasheets/5700_series.pdf +L_Toroid Vertical series Radial pin pitch 20.10mm length 54mm width 23.8mm Bourns 5700 +0 +2 +2 +Inductor_THT +L_Toroid_Vertical_L67.6mm_W36.1mm_P31.80mm_Vishay_TJ9 +L_Toroid, Vertical series, Radial, pin pitch=31.80mm, , length*width=67.6*36.1mm^2, Vishay, TJ9, http://www.vishay.com/docs/34079/tj.pdf +L_Toroid Vertical series Radial pin pitch 31.80mm length 67.6mm width 36.1mm Vishay TJ9 +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged2Bar_Pad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, bridged with 2 copper strips +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged2Bar_RoundedPad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm, rounded Pads, 0.3mm gap, bridged with 2 copper strips +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged_Pad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, bridged with 1 copper strip +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Bridged_RoundedPad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm, rounded Pads, 0.3mm gap, bridged with 1 copper strip +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Open_Pad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, open +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Open_RoundedPad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm, rounded Pads, 0.3mm gap, open +solder jumper open +0 +2 +2 +Jumper +SolderJumper-2_P1.3mm_Open_TrianglePad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Triangular Pads, 0.3mm gap, open +solder jumper open +0 +2 +2 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_Pad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_Pad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_RoundedPad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged2Bar12_RoundedPad1.0x1.5mm_NumberLabels +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 Bridged2Bar with 2 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_Pad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_Pad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_RoundedPad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Bridged12_RoundedPad1.0x1.5mm_NumberLabels +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, pads 1-2 bridged with 1 copper strip, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_Pad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm Pads, 0.3mm gap, open +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_Pad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, open, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_RoundedPad1.0x1.5mm +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, open +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P1.3mm_Open_RoundedPad1.0x1.5mm_NumberLabels +SMD Solder 3-pad Jumper, 1x1.5mm rounded Pads, 0.3mm gap, open, labeled with numbers +solder jumper open +0 +3 +3 +Jumper +SolderJumper-3_P2.0mm_Open_TrianglePad1.0x1.5mm +SMD Solder Jumper, 1x1.5mm Triangular Pads, 0.3mm gap, open +solder jumper open +0 +5 +3 +Jumper +SolderJumper-3_P2.0mm_Open_TrianglePad1.0x1.5mm_NumberLabels +SMD Solder Jumper, 1x1.5mm Triangular Pads, 0.3mm gap, open, labeled with numbers +solder jumper open +0 +5 +3 +LED_SMD +LED-APA102-2020 +http://www.led-color.com/upload/201604/APA102-2020%20SMD%20LED.pdf +LED RGB SPI +0 +8 +6 +LED_SMD +LED-L1T2_LUMILEDS +http://www.lumileds.com/uploads/438/DS133-pdf +LUMILEDS LUXEON TX L1T2 LED +0 +3 +3 +LED_SMD +LED_1W_3W_R8 +https://www.gme.cz/data/attachments/dsh.518-234.1.pdf +LED 1W 3W 5W +0 +3 +3 +LED_SMD +LED_0201_0603Metric +LED SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +LED +0 +4 +2 +LED_SMD +LED_0201_0603Metric_Castellated +LED SMD 0201 (0603 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +LED castellated +0 +4 +2 +LED_SMD +LED_0201_0603Metric_Pad0.64x0.40mm_HandSolder +LED SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +LED handsolder +0 +4 +2 +LED_SMD +LED_0402_1005Metric +LED SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_0402_1005Metric_Castellated +LED SMD 0402 (1005 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_0402_1005Metric_Pad0.77x0.64mm_HandSolder +LED SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_0603_1608Metric +LED SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_0603_1608Metric_Castellated +LED SMD 0603 (1608 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_0603_1608Metric_Pad1.05x0.95mm_HandSolder +LED SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_0805_2012Metric +LED SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_0805_2012Metric_Castellated +LED SMD 0805 (2012 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_0805_2012Metric_Pad1.15x1.40mm_HandSolder +LED SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_1206_3216Metric +LED SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_1206_3216Metric_Castellated +LED SMD 1206 (3216 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_1206_3216Metric_Pad1.42x1.75mm_HandSolder +LED SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_1206_3216Metric_ReverseMount_Hole1.8x2.4mm +LED SMD 1206 (3216 Metric), reverse mount, square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +diode reverse +0 +2 +2 +LED_SMD +LED_1210_3225Metric +LED SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_1210_3225Metric_Castellated +LED SMD 1210 (3225 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_1210_3225Metric_Pad1.42x2.65mm_HandSolder +LED SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_1812_4532Metric +LED SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_1812_4532Metric_Castellated +LED SMD 1812 (4532 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_1812_4532Metric_Pad1.30x3.40mm_HandSolder +LED SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_2010_5025Metric +LED SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_2010_5025Metric_Castellated +LED SMD 2010 (5025 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_2010_5025Metric_Pad1.52x2.65mm_HandSolder +LED SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_2512_6332Metric +LED SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_2512_6332Metric_Castellated +LED SMD 2512 (6332 Metric), castellated end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_2512_6332Metric_Pad1.52x3.35mm_HandSolder +LED SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_2816_7142Metric +LED SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +LED +0 +2 +2 +LED_SMD +LED_2816_7142Metric_Castellated +LED SMD 2816 (7142 Metric), castellated end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +LED castellated +0 +2 +2 +LED_SMD +LED_2816_7142Metric_Pad3.20x4.45mm_HandSolder +LED SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +LED handsolder +0 +2 +2 +LED_SMD +LED_ASMB-KTF0-0A306 +2220 Tricolor PLCC-4 LED, https://docs.broadcom.com/docs/ASMB-KTF0-0A306-DS100 +Tricolor LED +0 +4 +4 +LED_SMD +LED_Avago_PLCC4_3.2x2.8mm_CW +https://docs.broadcom.com/docs/AV02-4186EN +LED Avago PLCC-4 ASMB-MTB0-0A3A2 +0 +4 +4 +LED_SMD +LED_Avago_PLCC6_3x2.8mm +https://docs.broadcom.com/docs/AV02-3793EN +LED Avago PLCC-6 ASMT-YTB7-0AA02 +0 +6 +6 +LED_SMD +LED_Cree-PLCC4_2x2mm_CW +2.0mm x 2.0mm PLCC4 LED, http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/HB/Data-Sheets/CLMVBFKA.pdf +LED Cree PLCC-4 +0 +4 +4 +LED_SMD +LED_Cree-PLCC4_3.2x2.8mm_CCW +3.2mm x 2.8mm PLCC4 LED, http://www.cree.com/led-components/media/documents/CLV1AFKB(874).pdf +LED Cree PLCC-4 +0 +4 +4 +LED_SMD +LED_Cree-PLCC4_5x5mm_CW +5.0mm x 5.0mm PLCC4 LED +LED Cree PLCC-4 +0 +4 +4 +LED_SMD +LED_Cree-PLCC6_4.7x1.5mm +4.7mm x 1.5mm PLCC6 LED, http://www.cree.com/led-components/media/documents/1381-QLS6AFKW.pdf +LED Cree PLCC-6 +0 +6 +6 +LED_SMD +LED_Cree-XB +http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/XLampXBD.pdf +LED Cree XB +0 +5 +3 +LED_SMD +LED_Cree-XH +http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds-XHB.pdf +LED Cree XH +0 +8 +2 +LED_SMD +LED_Cree-XHP35 +http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds--XHP35.pdf +LED Cree XHP35 +0 +6 +3 +LED_SMD +LED_Cree-XHP50_6V +Cree XHP50, 6V footprint, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP50.pdf +LED Cree XHP50 +0 +15 +3 +LED_SMD +LED_Cree-XHP50_12V +Cree XHP50, 12V footprint, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP50.pdf +LED XHP50 Cree +0 +15 +3 +LED_SMD +LED_Cree-XHP70_6V +Cree XHP70 LED, 6V version, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP70.pdf +LED Cree XHP70 +0 +15 +3 +LED_SMD +LED_Cree-XHP70_12V +Cree XHP70 LED, 12V version, http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/ds%20XHP70.pdf +LED Cree XHP70 +0 +15 +3 +LED_SMD +LED_Cree-XP +LED Cree-XP http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/XLampXPE2.pdf +LED Cree XP +0 +6 +3 +LED_SMD +LED_Cree-XP-G +LED Cree-XP-G http://www.cree.com/~/media/Files/Cree/LED%20Components%20and%20Modules/XLamp/Data%20and%20Binning/XLampXPG.pdf +LED Cree XP-G +0 +6 +3 +LED_SMD +LED_Cree-XQ +LED Cree-XQ http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds-XQB.pdf +LED Cree XQ +0 +2 +2 +LED_SMD +LED_Cree-XQ_HandSoldering +LED Cree-XQ handsoldering pads http://www.cree.com/~/media/Files/Cree/LED-Components-and-Modules/XLamp/Data-and-Binning/ds-XQB.pdf +LED Cree XQ +0 +2 +2 +LED_SMD +LED_Dialight_591 +LED SMD 3mm Right Angle series (http://www.dialightsignalsandcomponents.com/Assets/Drawings/2D_Drawings_DrawingDetailedSpec/C17354.pdf) +LED Dialight 591 +0 +2 +2 +LED_SMD +LED_Inolux_IN-PI554FCH_PLCC4_5.0x5.0mm_P3.2mm +http://www.inolux-corp.com/datasheet/SMDLED/Addressable%20LED/IN-PI554FCH.pdf +RGB LED NeoPixel addressable +0 +4 +4 +LED_SMD +LED_Kingbright_AAA3528ESGCT +Kingbright, dual LED, 3.5 x 2.8 mm Surface Mount LED Lamp (http://www.kingbrightusa.com/images/catalog/SPEC/AAA3528ESGCT.pdf) +dual led smd +0 +4 +4 +LED_SMD +LED_Kingbright_APFA3010_3x1.5mm_Horizontal +LED RGB, APFA3010, http://www.kingbrightusa.com/images/catalog/SPEC/APFA3010LSEEZGKQBKC.pdf +LED RGB APFA3010 KINGBRIGHT 3x1.5mm +0 +4 +4 +LED_SMD +LED_LiteOn_LTST-C19HE1WT +LiteOn RGB LED; https://optoelectronics.liteon.com/upload/download/DS22-2008-0044/LTST-C19HE1WT.pdf +LED RGB Chip SMD +0 +4 +4 +LED_SMD +LED_LiteOn_LTST-S326 +http://optoelectronics.liteon.com/upload/download/DS22-2000-287/LTST-S326KGJRKT.PDF +LED SMD right angle CCA +0 +3 +3 +LED_SMD +LED_Lumex_SML-LX0303SIUPGUSB +Lumex RGB LED, clear, SMD, https://www.lumex.com/spec/SML-LX0303SIUPGUSB.pdf +LED RGB +0 +4 +4 +LED_SMD +LED_Osram_Lx_P47F_D2mm_ReverseMount +OSRAM, reverse-mount LED, SMD, 2mm diameter, http://www.farnell.com/datasheets/2711587.pdf +LED ReverseMount Reverse +0 +4 +2 +LED_SMD +LED_PLCC-2 +LED PLCC-2 SMD package +LED PLCC-2 SMD +0 +2 +2 +LED_SMD +LED_PLCC_2835 +https://www.luckylight.cn/media/component/data-sheet/R2835BC-B2M-M10.pdf +LED +0 +2 +2 +LED_SMD +LED_PLCC_2835_Handsoldering +https://www.luckylight.cn/media/component/data-sheet/R2835BC-B2M-M10.pdf +LED +0 +2 +2 +LED_SMD +LED_RGB_1210 +RGB LED 3.2x2.7mm http://www.avagotech.com/docs/AV02-0610EN +LED 3227 +0 +4 +4 +LED_SMD +LED_RGB_5050-6 +http://cdn.sparkfun.com/datasheets/Components/LED/5060BRG4.pdf +RGB LED 5050-6 +0 +6 +6 +LED_SMD +LED_RGB_Cree-PLCC-6_6x5mm_P2.1mm +http://www.farnell.com/datasheets/2003905.pdf +LED RGB PLCC-6 CLP6C-FBK +0 +6 +6 +LED_SMD +LED_RGB_Getian_GT-P6PRGB4303 +https://www.gme.sk/img/cache/doc/518/177/vykonova-led-getian-gt-p6prgb4303-datasheet-1.pdf +LED RGB +0 +7 +7 +LED_SMD +LED_RGB_PLCC-6 +RGB LED PLCC-6 +RGB LED PLCC-6 +0 +6 +6 +LED_SMD +LED_ROHM_SMLVN6 +https://www.rohm.com/datasheet/SMLVN6RGB1U +LED ROHM SMLVN6 +0 +6 +6 +LED_SMD +LED_SK6805_PLCC4_2.4x2.7mm_P1.3mm +https://cdn-shop.adafruit.com/product-files/3484/3484_Datasheet.pdf +LED RGB NeoPixel Nano +0 +4 +4 +LED_SMD +LED_SK6812MINI_PLCC4_3.5x3.5mm_P1.75mm +https://cdn-shop.adafruit.com/product-files/2686/SK6812MINI_REV.01-1-2.pdf +LED RGB NeoPixel Mini +0 +4 +4 +LED_SMD +LED_SK6812_EC15_1.5x1.5mm +http://www.newstar-ledstrip.com/product/20181119172602110.pdf +LED RGB NeoPixel +0 +4 +4 +LED_SMD +LED_SK6812_PLCC4_5.0x5.0mm_P3.2mm +https://cdn-shop.adafruit.com/product-files/1138/SK6812+LED+datasheet+.pdf +LED RGB NeoPixel +0 +4 +4 +LED_SMD +LED_WS2812B_PLCC4_5.0x5.0mm_P3.2mm +https://cdn-shop.adafruit.com/datasheets/WS2812B.pdf +LED RGB NeoPixel +0 +4 +4 +LED_SMD +LED_WS2812_PLCC6_5.0x5.0mm_P1.6mm +https://cdn-shop.adafruit.com/datasheets/WS2812.pdf +LED RGB NeoPixel +0 +6 +6 +LED_SMD +LED_Yuji_5730 +LED,Yuji,5730,https://cdn.shopify.com/s/files/1/0344/6401/files/YJWJ014-1.1_YJ-BC-5730L-G02.pdf +LED Yuji 5730 +0 +3 +2 +LED_SMD +LED_miniPLCC_2315 +https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DAV02-2205EN_DS_ASMT-TxBM_2014-05-09.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430858274704&ssbinary=true +LED +0 +2 +2 +LED_SMD +LED_miniPLCC_2315_Handsoldering +https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DAV02-2205EN_DS_ASMT-TxBM_2014-05-09.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430858274704&ssbinary=true +LED +0 +2 +2 +LED_SMD +SK6812MINI_underglow_dev_Silk_GND + + +0 +8 +4 +LED_THT +LED_BL-FL7680RGB +'Piranha' RGB LED, through hole, common anode, 7.62x7.62mm, BGRA pin order, https://cdn-shop.adafruit.com/datasheets/BL-FL7680RGB.pdf +RGB LED Piranha Super-Flux BetLux +0 +4 +4 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O1.27mm_Z1.6mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O1.27mm_Z4.9mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O1.27mm_Z8.2mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O3.81mm_Z1.6mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O3.81mm_Z4.9mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O3.81mm_Z8.2mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O6.35mm_Z1.6mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O6.35mm_Z4.9mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W1.8mm_H2.4mm_Horizontal_O6.35mm_Z8.2mm +LED, , diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm, 2 pins +LED diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 4.9mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 8.2mm 2 pins +0 +2 +2 +LED_THT +LED_D1.8mm_W3.3mm_H2.4mm +LED, Round, Rectangular size 3.3x2.4mm^2 diameter 1.8mm, 2 pins +LED Round Rectangular size 3.3x2.4mm^2 diameter 1.8mm 2 pins +0 +2 +2 +LED_THT +LED_D2.0mm_W4.0mm_H2.8mm_FlatTop +LED, Round, FlatTop, Rectangular size 4.0x2.8mm^2 diameter 2.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-1034IDT(Ver.9A).pdf +LED Round FlatTop Rectangular size 4.0x2.8mm^2 diameter 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D2.0mm_W4.8mm_H2.5mm_FlatTop +LED, Round, FlatTop, Rectangular size 4.8x2.5mm^2 diameter 2.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-13GD(Ver.11B).pdf +LED Round FlatTop Rectangular size 4.8x2.5mm^2 diameter 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm +LED, diameter 3.0mm, 2 pins +LED diameter 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm-3 +LED, diameter 3.0mm, 2 pins, diameter 3.0mm, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-3VSURKCGKC(Ver.8A).pdf +LED diameter 3.0mm 2 pins diameter 3.0mm 3 pins +0 +3 +3 +LED_THT +LED_D3.0mm_Clear +IR-LED, diameter 3.0mm, 2 pins, color: clear +IR infrared LED diameter 3.0mm 2 pins clear +0 +2 +2 +LED_THT +LED_D3.0mm_FlatTop +LED, Round, FlatTop, diameter 3.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-47XEC(Ver.9A).pdf +LED Round FlatTop diameter 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm_Clear +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm_IRBlack +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z2.0mm_IRGrey +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z6.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O1.27mm_Z10.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O3.81mm_Z2.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O3.81mm_Z6.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O3.81mm_Z10.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O6.35mm_Z2.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O6.35mm_Z6.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_Horizontal_O6.35mm_Z10.0mm +LED, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 2.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 6.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins, diameter 3.0mm z-position of LED center 10.0mm, 2 pins +LED diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 2.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 6.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins diameter 3.0mm z-position of LED center 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D3.0mm_IRBlack +IR-ED, diameter 3.0mm, 2 pins, color: black +IR infrared LED diameter 3.0mm 2 pins black +0 +2 +2 +LED_THT +LED_D3.0mm_IRGrey +IR-LED, diameter 3.0mm, 2 pins, color: grey +IR infrared LED diameter 3.0mm 2 pins grey +0 +2 +2 +LED_THT +LED_D4.0mm +LED, diameter 4.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-43GD(Ver.12B).pdf +LED diameter 4.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm-3 +LED, diameter 5.0mm, 2 pins, diameter 5.0mm, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-59EGC(Ver.17A).pdf +LED diameter 5.0mm 2 pins diameter 5.0mm 3 pins +0 +3 +3 +LED_THT +LED_D5.0mm-3_Horizontal_O3.81mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 3 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 3 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +3 +3 +LED_THT +LED_D5.0mm-4_RGB +LED, diameter 5.0mm, 2 pins, diameter 5.0mm, 3 pins, diameter 5.0mm, 4 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-154A4SUREQBFZGEW(Ver.9A).pdf +LED diameter 5.0mm 2 pins diameter 5.0mm 3 pins diameter 5.0mm 4 pins RGB RGBLED +0 +4 +4 +LED_THT +LED_D5.0mm-4_RGB_Staggered_Pins +LED, diameter 5.0mm, 4 pins, WP154A4, http://webtest4.kingbright.com/attachments/file/psearch/000/00/00/L-154A4SUREQBFZGEW(Ver.9A).pdf +rgb led +0 +4 +4 +LED_THT +LED_D5.0mm-4_RGB_Wide_Pins +LED, diameter 5.0mm, 2 pins, diameter 5.0mm, 3 pins, diameter 5.0mm, 4 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-154A4SUREQBFZGEW(Ver.9A).pdf +LED diameter 5.0mm 2 pins diameter 5.0mm 3 pins diameter 5.0mm 4 pins RGB RGBLED +0 +4 +4 +LED_THT +LED_D5.0mm_Clear +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_FlatTop +LED, Round, FlatTop, diameter 5.0mm, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-483GDT(Ver.15B).pdf +LED Round FlatTop diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm_Clear +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm_IRBlack +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z3.0mm_IRGrey +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z9.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O1.27mm_Z15.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O3.81mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O3.81mm_Z9.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O3.81mm_Z15.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O6.35mm_Z3.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O6.35mm_Z9.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_Horizontal_O6.35mm_Z15.0mm +LED, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 3.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 9.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins, diameter 5.0mm z-position of LED center 15.0mm, 2 pins +LED diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 3.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 9.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins diameter 5.0mm z-position of LED center 15.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_IRBlack +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D5.0mm_IRGrey +LED, diameter 5.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LL-504BC2E-009.pdf +LED diameter 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_D8.0mm +LED, diameter 8.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LED8MMGE_LED8MMGN_LED8MMRT%23KIN.pdf +LED diameter 8.0mm 2 pins +0 +2 +2 +LED_THT +LED_D8.0mm-3 +LED, diameter 8.0mm, 2 pins, diameter 8.0mm, 3 pins +LED diameter 8.0mm 2 pins diameter 8.0mm 3 pins +0 +3 +3 +LED_THT +LED_D10.0mm +LED, diameter 10.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LED10-4500RT%23KIN.pdf +LED diameter 10.0mm 2 pins +0 +2 +2 +LED_THT +LED_D10.0mm-3 +LED, diameter 10.0mm, 2 pins, diameter 10.0mm, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-819EGW(Ver.14A).pdf +LED diameter 10.0mm 2 pins diameter 10.0mm 3 pins +0 +3 +3 +LED_THT +LED_D20.0mm +LED, diameter 20.0mm, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/DLC2-6GD%28V6%29.pdf +LED diameter 20.0mm 2 pins +0 +2 +2 +LED_THT +LED_Oval_W5.2mm_H3.8mm +LED_Oval, Oval, Oval size 5.2x3.8mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-5603QBC-D(Ver.12B).pdf +LED_Oval Oval Oval size 5.2x3.8mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.0mm_H2.0mm +LED_Rectangular, Rectangular, Rectangular size 3.0x2.0mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 3.0x2.0mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.9mm_H1.8mm +LED_Rectangular, Rectangular, Rectangular size 3.9x1.8mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-2774GD(Ver.7B).pdf +LED_Rectangular Rectangular Rectangular size 3.9x1.8mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.9mm_H1.8mm_FlatTop +LED_Rectangular, Rectangular, Rectangular size 3.9x1.8mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-2774GD(Ver.7B).pdf +LED_Rectangular Rectangular Rectangular size 3.9x1.8mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W3.9mm_H1.9mm +LED_Rectangular, Rectangular, Rectangular size 3.9x1.9mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-144GDT(Ver.14B).pdf +LED_Rectangular Rectangular Rectangular size 3.9x1.9mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm-3Pins +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2, 3 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 3 pins +0 +3 +3 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O1.27mm_Z1.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O1.27mm_Z3.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O1.27mm_Z5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O3.81mm_Z1.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O3.81mm_Z3.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O3.81mm_Z5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O6.35mm_Z1.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O6.35mm_Z3.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H2.0mm_Horizontal_O6.35mm_Z5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins, Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm, 2 pins +LED_Rectangular Rectangular Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 1.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 5.0mm 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W5.0mm_H5.0mm +LED_Rectangular, Rectangular, Rectangular size 5.0x5.0mm^2, 2 pins, http://www.kingbright.com/attachments/file/psearch/000/00/00/L-169XCGDK(Ver.9B).pdf +LED_Rectangular Rectangular Rectangular size 5.0x5.0mm^2 2 pins +0 +2 +2 +LED_THT +LED_Rectangular_W7.62mm_H4.55mm_P5.08mm_R3 +Datasheet can be found at https://www.gme.cz/data/attachments/dsh.511-795.1.pdf +LED automotive super flux 7.62mm +0 +4 +2 +LED_THT +LED_SideEmitter_Rectangular_W4.5mm_H1.6mm +LED_SideEmitter_Rectangular, Rectangular, SideEmitter, Rectangular size 4.5x1.6mm^2, 2 pins, http://cdn-reichelt.de/documents/datenblatt/A500/LED15MMGE_LED15MMGN%23KIN.pdf +LED_SideEmitter_Rectangular Rectangular SideEmitter Rectangular size 4.5x1.6mm^2 2 pins +0 +2 +2 +LED_THT +LED_VCCLite_5381H1_6.35x6.35mm +Red 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Red 5381 Series LED +0 +2 +2 +LED_THT +LED_VCCLite_5381H3_6.35x6.35mm +Amber 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Amber 5381 Series LED +0 +2 +2 +LED_THT +LED_VCCLite_5381H5_6.35x6.35mm +Green 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Green 5381 Series LED +0 +2 +2 +LED_THT +LED_VCCLite_5381H7_6.35x6.35mm +Yellow 5381 Series LED VCCLite https://vcclite.com/wp-content/uploads/wpallimport/files/files/5381Series.pdf http://static.vcclite.com/pdf/Mounting%20Hole%20Pattern%202.pdf +Yellow 5381 Series LED +0 +2 +2 +Module +A20_OLINUXINO_LIME2 +A20 Olinuxino LIME2, 1.2GHz, 512-1024MB RAM, Micro-SD, NAND or eMMC, 1000Mbit Ethernet +A20 Olimex Olinuxino LIME2 development board +0 +180 +180 +Module +Adafruit_HUZZAH_ESP8266_breakout +32-bit microcontroller module with WiFi, https://www.adafruit.com/product/2471 +ESP8266 WiFi microcontroller +0 +20 +20 +Module +Adafruit_HUZZAH_ESP8266_breakout_WithMountingHoles +32-bit microcontroller module with WiFi, https://www.adafruit.com/product/2471 +ESP8266 WiFi microcontroller +0 +20 +20 +Module +Arduino_Nano +Arduino Nano, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino Nano +0 +30 +30 +Module +Arduino_Nano_WithMountingHoles +Arduino Nano, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino Nano +0 +30 +30 +Module +Arduino_UNO_R2 +Arduino UNO R2, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R2 +0 +30 +30 +Module +Arduino_UNO_R2_WithMountingHoles +Arduino UNO R2, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R2 +0 +30 +30 +Module +Arduino_UNO_R3 +Arduino UNO R3, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R3 +0 +32 +32 +Module +Arduino_UNO_R3_WithMountingHoles +Arduino UNO R3, http://www.mouser.com/pdfdocs/Gravitech_Arduino_Nano3_0.pdf +Arduino UNO R3 +0 +32 +32 +Module +BeagleBoard_PocketBeagle +PocketBeagle, https://github.com/beagleboard/pocketbeagle/wiki/System-Reference-Manual#71_Expansion_Header_Connectors +PocketBeagle +0 +72 +72 +Module +Maple_Mini +Maple Mini, http://docs.leaflabs.com/static.leaflabs.com/pub/leaflabs/maple-docs/0.0.12/hardware/maple-mini.html +Maple Mini +0 +40 +40 +Module +Onion_Omega2+ +https://onion.io/omega2/ +Omega Onion module +0 +32 +32 +Module +Onion_Omega2S +https://github.com/OnionIoT/Omega2/raw/master/Documents/Omega2S%20Datasheet.pdf +onion omega module +0 +89 +64 +Module +Pololu_Breakout-16_15.2x20.3mm +Pololu Breakout 16-pin 15.2x20.3mm 0.6x0.8\ +Pololu Breakout +0 +16 +16 +Module +Raspberry_Pi_Zero_Socketed_THT_FaceDown_MountingHoles +Raspberry Pi Zero using through hole straight pin socket, 2x20, 2.54mm pitch, https://www.raspberrypi.org/documentation/hardware/raspberrypi/mechanical/rpi_MECH_Zero_1p2.pdf +raspberry pi zero through hole +0 +40 +40 +Module +ST_Morpho_Connector_144_STLink +ST Morpho Connector 144 With STLink +ST Morpho Connector 144 STLink +0 +148 +148 +Module +ST_Morpho_Connector_144_STLink_MountingHoles +ST Morpho Connector 144 With STLink +ST Morpho Connector 144 STLink +0 +148 +148 +Module +Texas_EUK_R-PDSS-T7_THT +Texas Instruments EUK 7 Pin Double Sided Module +module pcb +0 +7 +7 +Module +Texas_EUS_R-PDSS-T5_THT +Texas Instruments EUS 5 Pin Double Sided Module +module pcb +0 +5 +5 +Module +Texas_EUW_R-PDSS-T7_THT +Texas Instruments EUW 7 Pin Double Sided Module +module pcb +0 +7 +7 +Module +WEMOS_D1_mini_light +16-pin module, column spacing 22.86 mm (900 mils), https://wiki.wemos.cc/products:d1:d1_mini, https://c1.staticflickr.com/1/734/31400410271_f278b087db_z.jpg +ESP8266 WiFi microcontroller +0 +16 +16 +MountingEquipment +DINRailAdapter_3xM3_PhoenixContact_1201578 +https://www.phoenixcontact.com/online/portal/us?uri=pxc-oc-itemdetail:pid=1201578&library=usen&tab=1 +DIN rail adapter universal three M3 clearance holes +0 +0 +0 +MountingHole +MountingHole_2.1mm +Mounting Hole 2.1mm, no annular +mounting hole 2.1mm no annular +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2 +Mounting Hole 2.2mm, no annular, M2 +mounting hole 2.2mm no annular m2 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_DIN965 +Mounting Hole 2.2mm, no annular, M2, DIN965 +mounting hole 2.2mm no annular m2 din965 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_DIN965_Pad +Mounting Hole 2.2mm, M2, DIN965 +mounting hole 2.2mm m2 din965 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_DIN965_Pad_TopBottom +Mounting Hole 2.2mm, M2, DIN965 +mounting hole 2.2mm m2 din965 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_DIN965_Pad_TopOnly +Mounting Hole 2.2mm, M2, DIN965 +mounting hole 2.2mm m2 din965 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_ISO7380 +Mounting Hole 2.2mm, no annular, M2, ISO7380 +mounting hole 2.2mm no annular m2 iso7380 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_ISO7380_Pad +Mounting Hole 2.2mm, M2, ISO7380 +mounting hole 2.2mm m2 iso7380 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_ISO7380_Pad_TopBottom +Mounting Hole 2.2mm, M2, ISO7380 +mounting hole 2.2mm m2 iso7380 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_ISO7380_Pad_TopOnly +Mounting Hole 2.2mm, M2, ISO7380 +mounting hole 2.2mm m2 iso7380 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_ISO14580 +Mounting Hole 2.2mm, no annular, M2, ISO14580 +mounting hole 2.2mm no annular m2 iso14580 +0 +0 +0 +MountingHole +MountingHole_2.2mm_M2_ISO14580_Pad +Mounting Hole 2.2mm, M2, ISO14580 +mounting hole 2.2mm m2 iso14580 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_ISO14580_Pad_TopBottom +Mounting Hole 2.2mm, M2, ISO14580 +mounting hole 2.2mm m2 iso14580 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_ISO14580_Pad_TopOnly +Mounting Hole 2.2mm, M2, ISO14580 +mounting hole 2.2mm m2 iso14580 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_Pad +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +1 +1 +MountingHole +MountingHole_2.2mm_M2_Pad_TopBottom +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +3 +1 +MountingHole +MountingHole_2.2mm_M2_Pad_TopOnly +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +2 +1 +MountingHole +MountingHole_2.2mm_M2_Pad_Via +Mounting Hole 2.2mm, M2 +mounting hole 2.2mm m2 +0 +9 +1 +MountingHole +MountingHole_2.5mm +Mounting Hole 2.5mm, no annular +mounting hole 2.5mm no annular +0 +0 +0 +MountingHole +MountingHole_2.5mm_Pad +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +1 +1 +MountingHole +MountingHole_2.5mm_Pad_TopBottom +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +3 +1 +MountingHole +MountingHole_2.5mm_Pad_TopOnly +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +2 +1 +MountingHole +MountingHole_2.5mm_Pad_Via +Mounting Hole 2.5mm +mounting hole 2.5mm +0 +9 +1 +MountingHole +MountingHole_2.7mm +Mounting Hole 2.7mm, no annular +mounting hole 2.7mm no annular +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5 +Mounting Hole 2.7mm, no annular, M2.5 +mounting hole 2.7mm no annular m2.5 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_DIN965 +Mounting Hole 2.7mm, no annular, M2.5, DIN965 +mounting hole 2.7mm no annular m2.5 din965 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_DIN965_Pad +Mounting Hole 2.7mm, M2.5, DIN965 +mounting hole 2.7mm m2.5 din965 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_DIN965_Pad_TopBottom +Mounting Hole 2.7mm, M2.5, DIN965 +mounting hole 2.7mm m2.5 din965 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_DIN965_Pad_TopOnly +Mounting Hole 2.7mm, M2.5, DIN965 +mounting hole 2.7mm m2.5 din965 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380 +Mounting Hole 2.7mm, no annular, M2.5, ISO7380 +mounting hole 2.7mm no annular m2.5 iso7380 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380_Pad +Mounting Hole 2.7mm, M2.5, ISO7380 +mounting hole 2.7mm m2.5 iso7380 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380_Pad_TopBottom +Mounting Hole 2.7mm, M2.5, ISO7380 +mounting hole 2.7mm m2.5 iso7380 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO7380_Pad_TopOnly +Mounting Hole 2.7mm, M2.5, ISO7380 +mounting hole 2.7mm m2.5 iso7380 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580 +Mounting Hole 2.7mm, no annular, M2.5, ISO14580 +mounting hole 2.7mm no annular m2.5 iso14580 +0 +0 +0 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580_Pad +Mounting Hole 2.7mm, M2.5, ISO14580 +mounting hole 2.7mm m2.5 iso14580 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580_Pad_TopBottom +Mounting Hole 2.7mm, M2.5, ISO14580 +mounting hole 2.7mm m2.5 iso14580 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_ISO14580_Pad_TopOnly +Mounting Hole 2.7mm, M2.5, ISO14580 +mounting hole 2.7mm m2.5 iso14580 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad +Mounting Hole 2.7mm, M2.5 +mounting hole 2.7mm m2.5 +0 +1 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad_TopBottom +Mounting Hole 2.7mm, M2.5 +mounting hole 2.7mm m2.5 +0 +3 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad_TopOnly +Mounting Hole 2.7mm, M2.5 +mounting hole 2.7mm m2.5 +0 +2 +1 +MountingHole +MountingHole_2.7mm_M2.5_Pad_Via +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +9 +1 +MountingHole +MountingHole_2.7mm_Pad +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +1 +1 +MountingHole +MountingHole_2.7mm_Pad_TopBottom +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +3 +1 +MountingHole +MountingHole_2.7mm_Pad_TopOnly +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +2 +1 +MountingHole +MountingHole_2.7mm_Pad_Via +Mounting Hole 2.7mm +mounting hole 2.7mm +0 +9 +1 +MountingHole +MountingHole_2mm +Mounting Hole 2mm, no annular +mounting hole 2mm no annular +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3 +Mounting Hole 3.2mm, no annular, M3 +mounting hole 3.2mm no annular m3 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_DIN965 +Mounting Hole 3.2mm, no annular, M3, DIN965 +mounting hole 3.2mm no annular m3 din965 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_DIN965_Pad +Mounting Hole 3.2mm, M3, DIN965 +mounting hole 3.2mm m3 din965 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_DIN965_Pad_TopBottom +Mounting Hole 3.2mm, M3, DIN965 +mounting hole 3.2mm m3 din965 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_DIN965_Pad_TopOnly +Mounting Hole 3.2mm, M3, DIN965 +mounting hole 3.2mm m3 din965 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_ISO7380 +Mounting Hole 3.2mm, no annular, M3, ISO7380 +mounting hole 3.2mm no annular m3 iso7380 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_ISO7380_Pad +Mounting Hole 3.2mm, M3, ISO7380 +mounting hole 3.2mm m3 iso7380 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_ISO7380_Pad_TopBottom +Mounting Hole 3.2mm, M3, ISO7380 +mounting hole 3.2mm m3 iso7380 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_ISO7380_Pad_TopOnly +Mounting Hole 3.2mm, M3, ISO7380 +mounting hole 3.2mm m3 iso7380 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_ISO14580 +Mounting Hole 3.2mm, no annular, M3, ISO14580 +mounting hole 3.2mm no annular m3 iso14580 +0 +0 +0 +MountingHole +MountingHole_3.2mm_M3_ISO14580_Pad +Mounting Hole 3.2mm, M3, ISO14580 +mounting hole 3.2mm m3 iso14580 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_ISO14580_Pad_TopBottom +Mounting Hole 3.2mm, M3, ISO14580 +mounting hole 3.2mm m3 iso14580 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_ISO14580_Pad_TopOnly +Mounting Hole 3.2mm, M3, ISO14580 +mounting hole 3.2mm m3 iso14580 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_Pad +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +1 +1 +MountingHole +MountingHole_3.2mm_M3_Pad_TopBottom +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +3 +1 +MountingHole +MountingHole_3.2mm_M3_Pad_TopOnly +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +2 +1 +MountingHole +MountingHole_3.2mm_M3_Pad_Via +Mounting Hole 3.2mm, M3 +mounting hole 3.2mm m3 +0 +9 +1 +MountingHole +MountingHole_3.5mm +Mounting Hole 3.5mm, no annular +mounting hole 3.5mm no annular +0 +0 +0 +MountingHole +MountingHole_3.5mm_Pad +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +1 +1 +MountingHole +MountingHole_3.5mm_Pad_TopBottom +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +3 +1 +MountingHole +MountingHole_3.5mm_Pad_TopOnly +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +2 +1 +MountingHole +MountingHole_3.5mm_Pad_Via +Mounting Hole 3.5mm +mounting hole 3.5mm +0 +9 +1 +MountingHole +MountingHole_3.7mm +Mounting Hole 3.7mm, no annular +mounting hole 3.7mm no annular +0 +0 +0 +MountingHole +MountingHole_3.7mm_Pad +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +1 +1 +MountingHole +MountingHole_3.7mm_Pad_TopBottom +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +3 +1 +MountingHole +MountingHole_3.7mm_Pad_TopOnly +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +2 +1 +MountingHole +MountingHole_3.7mm_Pad_Via +Mounting Hole 3.7mm +mounting hole 3.7mm +0 +9 +1 +MountingHole +MountingHole_3mm +Mounting Hole 3mm, no annular +mounting hole 3mm no annular +0 +0 +0 +MountingHole +MountingHole_3mm_Pad +Mounting Hole 3mm +mounting hole 3mm +0 +1 +1 +MountingHole +MountingHole_3mm_Pad_TopBottom +Mounting Hole 3mm +mounting hole 3mm +0 +3 +1 +MountingHole +MountingHole_3mm_Pad_TopOnly +Mounting Hole 3mm +mounting hole 3mm +0 +2 +1 +MountingHole +MountingHole_3mm_Pad_Via +Mounting Hole 3mm +mounting hole 3mm +0 +9 +1 +MountingHole +MountingHole_4.3mm_M4 +Mounting Hole 4.3mm, no annular, M4 +mounting hole 4.3mm no annular m4 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_DIN965 +Mounting Hole 4.3mm, no annular, M4, DIN965 +mounting hole 4.3mm no annular m4 din965 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_DIN965_Pad +Mounting Hole 4.3mm, M4, DIN965 +mounting hole 4.3mm m4 din965 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_DIN965_Pad_TopBottom +Mounting Hole 4.3mm, M4, DIN965 +mounting hole 4.3mm m4 din965 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_DIN965_Pad_TopOnly +Mounting Hole 4.3mm, M4, DIN965 +mounting hole 4.3mm m4 din965 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_ISO7380 +Mounting Hole 4.3mm, no annular, M4, ISO7380 +mounting hole 4.3mm no annular m4 iso7380 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_ISO7380_Pad +Mounting Hole 4.3mm, M4, ISO7380 +mounting hole 4.3mm m4 iso7380 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_ISO7380_Pad_TopBottom +Mounting Hole 4.3mm, M4, ISO7380 +mounting hole 4.3mm m4 iso7380 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_ISO7380_Pad_TopOnly +Mounting Hole 4.3mm, M4, ISO7380 +mounting hole 4.3mm m4 iso7380 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_ISO14580 +Mounting Hole 4.3mm, no annular, M4, ISO14580 +mounting hole 4.3mm no annular m4 iso14580 +0 +0 +0 +MountingHole +MountingHole_4.3mm_M4_ISO14580_Pad +Mounting Hole 4.3mm, M4, ISO14580 +mounting hole 4.3mm m4 iso14580 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_ISO14580_Pad_TopBottom +Mounting Hole 4.3mm, M4, ISO14580 +mounting hole 4.3mm m4 iso14580 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_ISO14580_Pad_TopOnly +Mounting Hole 4.3mm, M4, ISO14580 +mounting hole 4.3mm m4 iso14580 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_Pad +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +1 +1 +MountingHole +MountingHole_4.3mm_M4_Pad_TopBottom +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +3 +1 +MountingHole +MountingHole_4.3mm_M4_Pad_TopOnly +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +2 +1 +MountingHole +MountingHole_4.3mm_M4_Pad_Via +Mounting Hole 4.3mm, M4 +mounting hole 4.3mm m4 +0 +9 +1 +MountingHole +MountingHole_4.3x6.2mm_M4_Pad +Mounting Hole 4.3x6.2mm, M4 +mounting hole 4.3x6.2mm m4 +0 +1 +1 +MountingHole +MountingHole_4.3x6.2mm_M4_Pad_Via +Mounting Hole 4.3x6.2mm, M4 +mounting hole 4.3x6.2mm m4 +0 +17 +1 +MountingHole +MountingHole_4.5mm +Mounting Hole 4.5mm, no annular +mounting hole 4.5mm no annular +0 +0 +0 +MountingHole +MountingHole_4.5mm_Pad +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +1 +1 +MountingHole +MountingHole_4.5mm_Pad_TopBottom +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +3 +1 +MountingHole +MountingHole_4.5mm_Pad_TopOnly +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +2 +1 +MountingHole +MountingHole_4.5mm_Pad_Via +Mounting Hole 4.5mm +mounting hole 4.5mm +0 +9 +1 +MountingHole +MountingHole_4mm +Mounting Hole 4mm, no annular +mounting hole 4mm no annular +0 +0 +0 +MountingHole +MountingHole_4mm_Pad +Mounting Hole 4mm +mounting hole 4mm +0 +1 +1 +MountingHole +MountingHole_4mm_Pad_TopBottom +Mounting Hole 4mm +mounting hole 4mm +0 +3 +1 +MountingHole +MountingHole_4mm_Pad_TopOnly +Mounting Hole 4mm +mounting hole 4mm +0 +2 +1 +MountingHole +MountingHole_4mm_Pad_Via +Mounting Hole 4mm +mounting hole 4mm +0 +9 +1 +MountingHole +MountingHole_5.3mm_M5 +Mounting Hole 5.3mm, no annular, M5 +mounting hole 5.3mm no annular m5 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_DIN965 +Mounting Hole 5.3mm, no annular, M5, DIN965 +mounting hole 5.3mm no annular m5 din965 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_DIN965_Pad +Mounting Hole 5.3mm, M5, DIN965 +mounting hole 5.3mm m5 din965 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_DIN965_Pad_TopBottom +Mounting Hole 5.3mm, M5, DIN965 +mounting hole 5.3mm m5 din965 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_DIN965_Pad_TopOnly +Mounting Hole 5.3mm, M5, DIN965 +mounting hole 5.3mm m5 din965 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_ISO7380 +Mounting Hole 5.3mm, no annular, M5, ISO7380 +mounting hole 5.3mm no annular m5 iso7380 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_ISO7380_Pad +Mounting Hole 5.3mm, M5, ISO7380 +mounting hole 5.3mm m5 iso7380 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_ISO7380_Pad_TopBottom +Mounting Hole 5.3mm, M5, ISO7380 +mounting hole 5.3mm m5 iso7380 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_ISO7380_Pad_TopOnly +Mounting Hole 5.3mm, M5, ISO7380 +mounting hole 5.3mm m5 iso7380 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_ISO14580 +Mounting Hole 5.3mm, no annular, M5, ISO14580 +mounting hole 5.3mm no annular m5 iso14580 +0 +0 +0 +MountingHole +MountingHole_5.3mm_M5_ISO14580_Pad +Mounting Hole 5.3mm, M5, ISO14580 +mounting hole 5.3mm m5 iso14580 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_ISO14580_Pad_TopBottom +Mounting Hole 5.3mm, M5, ISO14580 +mounting hole 5.3mm m5 iso14580 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_ISO14580_Pad_TopOnly +Mounting Hole 5.3mm, M5, ISO14580 +mounting hole 5.3mm m5 iso14580 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_Pad +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +1 +1 +MountingHole +MountingHole_5.3mm_M5_Pad_TopBottom +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +3 +1 +MountingHole +MountingHole_5.3mm_M5_Pad_TopOnly +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +2 +1 +MountingHole +MountingHole_5.3mm_M5_Pad_Via +Mounting Hole 5.3mm, M5 +mounting hole 5.3mm m5 +0 +9 +1 +MountingHole +MountingHole_5.5mm +Mounting Hole 5.5mm, no annular +mounting hole 5.5mm no annular +0 +0 +0 +MountingHole +MountingHole_5.5mm_Pad +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +1 +1 +MountingHole +MountingHole_5.5mm_Pad_TopBottom +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +3 +1 +MountingHole +MountingHole_5.5mm_Pad_TopOnly +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +2 +1 +MountingHole +MountingHole_5.5mm_Pad_Via +Mounting Hole 5.5mm +mounting hole 5.5mm +0 +9 +1 +MountingHole +MountingHole_5mm +Mounting Hole 5mm, no annular +mounting hole 5mm no annular +0 +0 +0 +MountingHole +MountingHole_5mm_Pad +Mounting Hole 5mm +mounting hole 5mm +0 +1 +1 +MountingHole +MountingHole_5mm_Pad_TopBottom +Mounting Hole 5mm +mounting hole 5mm +0 +3 +1 +MountingHole +MountingHole_5mm_Pad_TopOnly +Mounting Hole 5mm +mounting hole 5mm +0 +2 +1 +MountingHole +MountingHole_5mm_Pad_Via +Mounting Hole 5mm +mounting hole 5mm +0 +9 +1 +MountingHole +MountingHole_6.4mm_M6 +Mounting Hole 6.4mm, no annular, M6 +mounting hole 6.4mm no annular m6 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_DIN965 +Mounting Hole 6.4mm, no annular, M6, DIN965 +mounting hole 6.4mm no annular m6 din965 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_DIN965_Pad +Mounting Hole 6.4mm, M6, DIN965 +mounting hole 6.4mm m6 din965 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_DIN965_Pad_TopBottom +Mounting Hole 6.4mm, M6, DIN965 +mounting hole 6.4mm m6 din965 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_DIN965_Pad_TopOnly +Mounting Hole 6.4mm, M6, DIN965 +mounting hole 6.4mm m6 din965 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_ISO7380 +Mounting Hole 6.4mm, no annular, M6, ISO7380 +mounting hole 6.4mm no annular m6 iso7380 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_ISO7380_Pad +Mounting Hole 6.4mm, M6, ISO7380 +mounting hole 6.4mm m6 iso7380 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_ISO7380_Pad_TopBottom +Mounting Hole 6.4mm, M6, ISO7380 +mounting hole 6.4mm m6 iso7380 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_ISO7380_Pad_TopOnly +Mounting Hole 6.4mm, M6, ISO7380 +mounting hole 6.4mm m6 iso7380 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_ISO14580 +Mounting Hole 6.4mm, no annular, M6, ISO14580 +mounting hole 6.4mm no annular m6 iso14580 +0 +0 +0 +MountingHole +MountingHole_6.4mm_M6_ISO14580_Pad +Mounting Hole 6.4mm, M6, ISO14580 +mounting hole 6.4mm m6 iso14580 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_ISO14580_Pad_TopBottom +Mounting Hole 6.4mm, M6, ISO14580 +mounting hole 6.4mm m6 iso14580 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_ISO14580_Pad_TopOnly +Mounting Hole 6.4mm, M6, ISO14580 +mounting hole 6.4mm m6 iso14580 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_Pad +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +1 +1 +MountingHole +MountingHole_6.4mm_M6_Pad_TopBottom +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +3 +1 +MountingHole +MountingHole_6.4mm_M6_Pad_TopOnly +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +2 +1 +MountingHole +MountingHole_6.4mm_M6_Pad_Via +Mounting Hole 6.4mm, M6 +mounting hole 6.4mm m6 +0 +9 +1 +MountingHole +MountingHole_6.5mm +Mounting Hole 6.5mm, no annular +mounting hole 6.5mm no annular +0 +0 +0 +MountingHole +MountingHole_6.5mm_Pad +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +1 +1 +MountingHole +MountingHole_6.5mm_Pad_TopBottom +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +3 +1 +MountingHole +MountingHole_6.5mm_Pad_TopOnly +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +2 +1 +MountingHole +MountingHole_6.5mm_Pad_Via +Mounting Hole 6.5mm +mounting hole 6.5mm +0 +9 +1 +MountingHole +MountingHole_6mm +Mounting Hole 6mm, no annular +mounting hole 6mm no annular +0 +0 +0 +MountingHole +MountingHole_6mm_Pad +Mounting Hole 6mm +mounting hole 6mm +0 +1 +1 +MountingHole +MountingHole_6mm_Pad_TopBottom +Mounting Hole 6mm +mounting hole 6mm +0 +3 +1 +MountingHole +MountingHole_6mm_Pad_TopOnly +Mounting Hole 6mm +mounting hole 6mm +0 +2 +1 +MountingHole +MountingHole_6mm_Pad_Via +Mounting Hole 6mm +mounting hole 6mm +0 +9 +1 +MountingHole +MountingHole_8.4mm_M8 +Mounting Hole 8.4mm, no annular, M8 +mounting hole 8.4mm no annular m8 +0 +0 +0 +MountingHole +MountingHole_8.4mm_M8_Pad +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +1 +1 +MountingHole +MountingHole_8.4mm_M8_Pad_TopBottom +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +3 +1 +MountingHole +MountingHole_8.4mm_M8_Pad_TopOnly +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +2 +1 +MountingHole +MountingHole_8.4mm_M8_Pad_Via +Mounting Hole 8.4mm, M8 +mounting hole 8.4mm m8 +0 +9 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H5mm_9771050360 +Mounting Hardware, external M3, height 5, Wuerth electronics 9771050360 (https://katalog.we-online.com/em/datasheet/9771050360.pdf), generated with kicad-footprint-generator +Mounting M3 9771050360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H6mm_9771060360 +Mounting Hardware, external M3, height 6, Wuerth electronics 9771060360 (https://katalog.we-online.com/em/datasheet/9771060360.pdf), generated with kicad-footprint-generator +Mounting M3 9771060360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H7mm_9771070360 +Mounting Hardware, external M3, height 7, Wuerth electronics 9771070360 (https://katalog.we-online.com/em/datasheet/9771070360.pdf), generated with kicad-footprint-generator +Mounting M3 9771070360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H8mm_9771080360 +Mounting Hardware, external M3, height 8, Wuerth electronics 9771080360 (https://katalog.we-online.com/em/datasheet/9771080360.pdf), generated with kicad-footprint-generator +Mounting M3 9771080360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H9mm_9771090360 +Mounting Hardware, external M3, height 9, Wuerth electronics 9771090360 (https://katalog.we-online.com/em/datasheet/9771090360.pdf), generated with kicad-footprint-generator +Mounting M3 9771090360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H10mm_9771100360 +Mounting Hardware, external M3, height 10, Wuerth electronics 9771100360 (https://katalog.we-online.com/em/datasheet/9771100360.pdf), generated with kicad-footprint-generator +Mounting M3 9771100360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H11mm_9771110360 +Mounting Hardware, external M3, height 11, Wuerth electronics 9771110360 (https://katalog.we-online.com/em/datasheet/9771110360.pdf), generated with kicad-footprint-generator +Mounting M3 9771110360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H12mm_9771120360 +Mounting Hardware, external M3, height 12, Wuerth electronics 9771120360 (https://katalog.we-online.com/em/datasheet/9771120360.pdf), generated with kicad-footprint-generator +Mounting M3 9771120360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H13mm_9771130360 +Mounting Hardware, external M3, height 13, Wuerth electronics 9771130360 (https://katalog.we-online.com/em/datasheet/9771130360.pdf), generated with kicad-footprint-generator +Mounting M3 9771130360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H14mm_9771140360 +Mounting Hardware, external M3, height 14, Wuerth electronics 9771140360 (https://katalog.we-online.com/em/datasheet/9771140360.pdf), generated with kicad-footprint-generator +Mounting M3 9771140360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSE-ExternalM3_H15mm_9771150360 +Mounting Hardware, external M3, height 15, Wuerth electronics 9771150360 (https://katalog.we-online.com/em/datasheet/9771150360.pdf), generated with kicad-footprint-generator +Mounting M3 9771150360 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H1mm_9774010482 +Mounting Hardware, inside through hole 4.5mm, height 1, Wuerth electronics 9774010482 (https://katalog.we-online.de/em/datasheet/9774010482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774010482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H2mm_9774020482 +Mounting Hardware, inside through hole 4.5mm, height 2, Wuerth electronics 9774020482 (https://katalog.we-online.de/em/datasheet/9774020482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774020482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H3mm_9774030482 +Mounting Hardware, inside through hole 4.5mm, height 3, Wuerth electronics 9774030482 (https://katalog.we-online.de/em/datasheet/9774030482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774030482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H4mm_9774040482 +Mounting Hardware, inside through hole 4.5mm, height 4, Wuerth electronics 9774040482 (https://katalog.we-online.de/em/datasheet/9774040482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774040482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H5mm_9774050482 +Mounting Hardware, inside through hole 4.5mm, height 5, Wuerth electronics 9774050482 (https://katalog.we-online.de/em/datasheet/9774050482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774050482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H6mm_9774060482 +Mounting Hardware, inside through hole 4.5mm, height 6, Wuerth electronics 9774060482 (https://katalog.we-online.de/em/datasheet/9774060482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774060482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H7mm_9774070482 +Mounting Hardware, inside through hole 4.5mm, height 7, Wuerth electronics 9774070482 (https://katalog.we-online.de/em/datasheet/9774070482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774070482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H8mm_9774080482 +Mounting Hardware, inside through hole 4.5mm, height 8, Wuerth electronics 9774080482 (https://katalog.we-online.de/em/datasheet/9774080482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774080482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H9mm_9774090482 +Mounting Hardware, inside through hole 4.5mm, height 9, Wuerth electronics 9774090482 (https://katalog.we-online.de/em/datasheet/9774090482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774090482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-4.5mm_H10mm_9774100482 +Mounting Hardware, inside through hole 4.5mm, height 10, Wuerth electronics 9774100482 (https://katalog.we-online.de/em/datasheet/9774100482.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774100482 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H1.5mm_9774015633 +Mounting Hardware, inside through hole M1.6, height 1.5, Wuerth electronics 9774015633 (https://katalog.we-online.com/em/datasheet/9774015633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774015633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H1mm_9774010633 +Mounting Hardware, inside through hole M1.6, height 1, Wuerth electronics 9774010633 (https://katalog.we-online.com/em/datasheet/9774010633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774010633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2.5mm_9774025633 +Mounting Hardware, inside through hole M1.6, height 2.5, Wuerth electronics 9774025633 (https://katalog.we-online.com/em/datasheet/9774025633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774025633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2.5mm_ThreadDepth1.5mm_97730256332 +Mounting Hardware, inside blind hole M1.6, height 2.5, Wuerth electronics 97730256332 (https://katalog.we-online.com/em/datasheet/97730256332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730256332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2.5mm_ThreadDepth1.5mm_NoNPTH_97730256330 +Mounting Hardware, inside blind hole M1.6, height 2.5, Wuerth electronics 97730256330 (https://katalog.we-online.com/em/datasheet/97730256330R.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730256330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H2mm_9774020633 +Mounting Hardware, inside through hole M1.6, height 2, Wuerth electronics 9774020633 (https://katalog.we-online.com/em/datasheet/9774020633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774020633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3.5mm_ThreadDepth2mm_97730356332 +Mounting Hardware, inside blind hole M1.6, height 3.5, Wuerth electronics 97730356332 (https://katalog.we-online.com/em/datasheet/97730356332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730356332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3.5mm_ThreadDepth2mm_97730356334 +Mounting Hardware, inside blind hole M1.6, height 3.5, Wuerth electronics 97730356334 (https://katalog.we-online.com/em/datasheet/97730356334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730356334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3.5mm_ThreadDepth2mm_NoNPTH_97730356330 +Mounting Hardware, inside blind hole M1.6, height 3.5, Wuerth electronics 97730356330 (https://katalog.we-online.com/em/datasheet/97730356330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730356330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3mm_9774030633 +Mounting Hardware, inside through hole M1.6, height 3, Wuerth electronics 9774030633 (https://katalog.we-online.com/em/datasheet/9774030633.pdf), generated with kicad-footprint-generator +Mounting M1.6 9774030633 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3mm_ThreadDepth1.8mm_97730306332 +Mounting Hardware, inside blind hole M1.6, height 3, Wuerth electronics 97730306332 (https://katalog.we-online.com/em/datasheet/97730306332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730306332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H3mm_ThreadDepth1.8mm_NoNPTH_97730306330 +Mounting Hardware, inside blind hole M1.6, height 3, Wuerth electronics 97730306330 (https://katalog.we-online.com/em/datasheet/97730306330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730306330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4.5mm_ThreadDepth2mm_97730456332 +Mounting Hardware, inside blind hole M1.6, height 4.5, Wuerth electronics 97730456332 (https://katalog.we-online.com/em/datasheet/97730456332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730456332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4.5mm_ThreadDepth2mm_97730456334 +Mounting Hardware, inside blind hole M1.6, height 4.5, Wuerth electronics 97730456334 (https://katalog.we-online.com/em/datasheet/97730456334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730456334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4.5mm_ThreadDepth2mm_NoNPTH_97730456330 +Mounting Hardware, inside blind hole M1.6, height 4.5, Wuerth electronics 97730456330 (https://katalog.we-online.com/em/datasheet/97730456330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730456330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4mm_ThreadDepth2mm_97730406332 +Mounting Hardware, inside blind hole M1.6, height 4, Wuerth electronics 97730406332 (https://katalog.we-online.com/em/datasheet/97730406332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730406332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4mm_ThreadDepth2mm_97730406334 +Mounting Hardware, inside blind hole M1.6, height 4, Wuerth electronics 97730406334 (https://katalog.we-online.com/em/datasheet/97730406334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730406334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H4mm_ThreadDepth2mm_NoNPTH_97730406330 +Mounting Hardware, inside blind hole M1.6, height 4, Wuerth electronics 97730406330 (https://katalog.we-online.com/em/datasheet/97730406330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730406330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H5mm_ThreadDepth2mm_97730506332 +Mounting Hardware, inside blind hole M1.6, height 5, Wuerth electronics 97730506332 (https://katalog.we-online.com/em/datasheet/97730506332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730506332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H5mm_ThreadDepth2mm_97730506334 +Mounting Hardware, inside blind hole M1.6, height 5, Wuerth electronics 97730506334 (https://katalog.we-online.com/em/datasheet/97730506334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730506334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H5mm_ThreadDepth2mm_NoNPTH_97730506330 +Mounting Hardware, inside blind hole M1.6, height 5, Wuerth electronics 97730506330 (https://katalog.we-online.com/em/datasheet/97730506330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730506330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H6mm_ThreadDepth2mm_97730606332 +Mounting Hardware, inside blind hole M1.6, height 6, Wuerth electronics 97730606332 (https://katalog.we-online.com/em/datasheet/97730606332.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730606332 +0 +6 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H6mm_ThreadDepth2mm_97730606334 +Mounting Hardware, inside blind hole M1.6, height 6, Wuerth electronics 97730606334 (https://katalog.we-online.com/em/datasheet/97730606334.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730606334 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M1.6_H6mm_ThreadDepth2mm_NoNPTH_97730606330 +Mounting Hardware, inside blind hole M1.6, height 6, Wuerth electronics 97730606330 (https://katalog.we-online.com/em/datasheet/97730606330.pdf), generated with kicad-footprint-generator +Mounting M1.6 97730606330 +0 +5 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H1.5mm_9774015243 +Mounting Hardware, inside through hole M2, height 1.5, Wuerth electronics 9774015243 (https://katalog.we-online.de/em/datasheet/9774015243.pdf), generated with kicad-footprint-generator +Mounting M2 9774015243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H1mm_9774010243 +Mounting Hardware, inside through hole M2, height 1, Wuerth electronics 9774010243 (https://katalog.we-online.de/em/datasheet/9774010243.pdf), generated with kicad-footprint-generator +Mounting M2 9774010243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H2.5mm_9774025243 +Mounting Hardware, inside through hole M2, height 2.5, Wuerth electronics 9774025243 (https://katalog.we-online.de/em/datasheet/9774025243.pdf), generated with kicad-footprint-generator +Mounting M2 9774025243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H2mm_9774020243 +Mounting Hardware, inside through hole M2, height 2, Wuerth electronics 9774020243 (https://katalog.we-online.de/em/datasheet/9774020243.pdf), generated with kicad-footprint-generator +Mounting M2 9774020243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H3.5mm_9774035243 +Mounting Hardware, inside through hole M2, height 3.5, Wuerth electronics 9774035243 (https://katalog.we-online.de/em/datasheet/9774035243.pdf), generated with kicad-footprint-generator +Mounting M2 9774035243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H3mm_9774030243 +Mounting Hardware, inside through hole M2, height 3, Wuerth electronics 9774030243 (https://katalog.we-online.de/em/datasheet/9774030243.pdf), generated with kicad-footprint-generator +Mounting M2 9774030243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H4.5mm_9774045243 +Mounting Hardware, inside through hole M2, height 4.5, Wuerth electronics 9774045243 (https://katalog.we-online.de/em/datasheet/9774045243.pdf), generated with kicad-footprint-generator +Mounting M2 9774045243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H4mm_9774040243 +Mounting Hardware, inside through hole M2, height 4, Wuerth electronics 9774040243 (https://katalog.we-online.de/em/datasheet/9774040243.pdf), generated with kicad-footprint-generator +Mounting M2 9774040243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H5mm_9774050243 +Mounting Hardware, inside through hole M2, height 5, Wuerth electronics 9774050243 (https://katalog.we-online.de/em/datasheet/9774050243.pdf), generated with kicad-footprint-generator +Mounting M2 9774050243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H6mm_9774060243 +Mounting Hardware, inside through hole M2, height 6, Wuerth electronics 9774060243 (https://katalog.we-online.de/em/datasheet/9774060243.pdf), generated with kicad-footprint-generator +Mounting M2 9774060243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H7mm_9774070243 +Mounting Hardware, inside through hole M2, height 7, Wuerth electronics 9774070243 (https://katalog.we-online.de/em/datasheet/9774070243.pdf), generated with kicad-footprint-generator +Mounting M2 9774070243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M2_H8mm_9774080243 +Mounting Hardware, inside through hole M2, height 8, Wuerth electronics 9774080243 (https://katalog.we-online.de/em/datasheet/9774080243.pdf), generated with kicad-footprint-generator +Mounting M2 9774080243 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H1.5mm_9774015360 +Mounting Hardware, inside through hole M3, height 1.5, Wuerth electronics 9774015360 (https://katalog.we-online.de/em/datasheet/9774015360.pdf), generated with kicad-footprint-generator +Mounting M3 9774015360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H1mm_9774010360 +Mounting Hardware, inside through hole M3, height 1, Wuerth electronics 9774010360 (https://katalog.we-online.de/em/datasheet/9774010360.pdf), generated with kicad-footprint-generator +Mounting M3 9774010360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H2.5mm_9774025360 +Mounting Hardware, inside through hole M3, height 2.5, Wuerth electronics 9774025360 (https://katalog.we-online.de/em/datasheet/9774025360.pdf), generated with kicad-footprint-generator +Mounting M3 9774025360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H2mm_9774020360 +Mounting Hardware, inside through hole M3, height 2, Wuerth electronics 9774020360 (https://katalog.we-online.de/em/datasheet/9774020360.pdf), generated with kicad-footprint-generator +Mounting M3 9774020360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H3mm_9774030360 +Mounting Hardware, inside through hole M3, height 3, Wuerth electronics 9774030360 (https://katalog.we-online.de/em/datasheet/9774030360R.pdf), generated with kicad-footprint-generator +Mounting M3 9774030360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H4mm_9774040360 +Mounting Hardware, inside through hole M3, height 4, Wuerth electronics 9774040360 (https://katalog.we-online.de/em/datasheet/9774040360.pdf), generated with kicad-footprint-generator +Mounting M3 9774040360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H5mm_9774050360 +Mounting Hardware, inside through hole M3, height 5, Wuerth electronics 9774050360 (https://katalog.we-online.de/em/datasheet/9774050360.pdf), generated with kicad-footprint-generator +Mounting M3 9774050360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H6mm_9774060360 +Mounting Hardware, inside through hole M3, height 6, Wuerth electronics 9774060360 (https://katalog.we-online.de/em/datasheet/9774060360.pdf), generated with kicad-footprint-generator +Mounting M3 9774060360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H7mm_9774070360 +Mounting Hardware, inside through hole M3, height 7, Wuerth electronics 9774070360 (https://katalog.we-online.de/em/datasheet/9774070360.pdf), generated with kicad-footprint-generator +Mounting M3 9774070360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H8mm_9774080360 +Mounting Hardware, inside through hole M3, height 8, Wuerth electronics 9774080360 (https://katalog.we-online.de/em/datasheet/9774080360.pdf), generated with kicad-footprint-generator +Mounting M3 9774080360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H9mm_9774090360 +Mounting Hardware, inside through hole M3, height 9, Wuerth electronics 9774090360 (https://katalog.we-online.de/em/datasheet/9774090360.pdf), generated with kicad-footprint-generator +Mounting M3 9774090360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H10mm_9774100360 +Mounting Hardware, inside through hole M3, height 10, Wuerth electronics 9774100360 (https://katalog.we-online.de/em/datasheet/9774100360.pdf), generated with kicad-footprint-generator +Mounting M3 9774100360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H11mm_9774110360 +Mounting Hardware, inside through hole M3, height 11, Wuerth electronics 9774110360 (https://katalog.we-online.de/em/datasheet/9774110360.pdf), generated with kicad-footprint-generator +Mounting M3 9774110360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H12mm_9774120360 +Mounting Hardware, inside through hole M3, height 12, Wuerth electronics 9774120360 (https://katalog.we-online.de/em/datasheet/9774120360.pdf), generated with kicad-footprint-generator +Mounting M3 9774120360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H13mm_9774130360 +Mounting Hardware, inside through hole M3, height 13, Wuerth electronics 9774130360 (https://katalog.we-online.de/em/datasheet/9774130360.pdf), generated with kicad-footprint-generator +Mounting M3 9774130360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H14mm_9774140360 +Mounting Hardware, inside through hole M3, height 14, Wuerth electronics 9774140360 (https://katalog.we-online.de/em/datasheet/9774140360.pdf), generated with kicad-footprint-generator +Mounting M3 9774140360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSI-M3_H15mm_9774150360 +Mounting Hardware, inside through hole M3, height 15, Wuerth electronics 9774150360 (https://katalog.we-online.de/em/datasheet/9774150360.pdf), generated with kicad-footprint-generator +Mounting M3 9774150360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H2.6mm_ReverseMount_9775026960 +Mounting Hardware, inside through hole 3.2mm, height 2.6, Wuerth electronics 9775026960 (https://katalog.we-online.com/em/datasheet/9775026960R.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775026960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H3.1mm_ReverseMount_9775031960 +Mounting Hardware, inside through hole 3.2mm, height 3.1, Wuerth electronics 9775031960 (https://katalog.we-online.com/em/datasheet/9775031960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775031960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H3.6mm_ReverseMount_9775036960 +Mounting Hardware, inside through hole 3.2mm, height 3.6, Wuerth electronics 9775036960 (https://katalog.we-online.com/em/datasheet/9775036960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775036960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H4.1mm_ReverseMount_9775041960 +Mounting Hardware, inside through hole 3.2mm, height 4.1, Wuerth electronics 9775041960 (https://katalog.we-online.com/em/datasheet/9775041960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775041960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H4.6mm_ReverseMount_9775046960 +Mounting Hardware, inside through hole 3.2mm, height 4.6, Wuerth electronics 9775046960 (https://katalog.we-online.com/em/datasheet/9775046960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775046960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H5.1mm_ReverseMount_9775051960 +Mounting Hardware, inside through hole 3.2mm, height 5.1, Wuerth electronics 9775051960 (https://katalog.we-online.com/em/datasheet/9775051960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775051960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H5.6mm_ReverseMount_9775056960 +Mounting Hardware, inside through hole 3.2mm, height 5.6, Wuerth electronics 9775056960 (https://katalog.we-online.com/em/datasheet/9775056960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775056960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H6.6mm_ReverseMount_9775066960 +Mounting Hardware, inside through hole 3.2mm, height 6.6, Wuerth electronics 9775066960 (https://katalog.we-online.com/em/datasheet/9775066960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775066960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H7.6mm_ReverseMount_9775076960 +Mounting Hardware, inside through hole 3.2mm, height 7.6, Wuerth electronics 9775076960 (https://katalog.we-online.com/em/datasheet/9775076960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775076960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H8.6mm_ReverseMount_9775086960 +Mounting Hardware, inside through hole 3.2mm, height 8.6, Wuerth electronics 9775086960 (https://katalog.we-online.com/em/datasheet/9775086960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775086960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H9.6mm_ReverseMount_9775096960 +Mounting Hardware, inside through hole 3.2mm, height 9.6, Wuerth electronics 9775096960 (https://katalog.we-online.com/em/datasheet/9775096960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775096960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H10.6mm_ReverseMount_9775106960 +Mounting Hardware, inside through hole 3.2mm, height 10.6, Wuerth electronics 9775106960 (https://katalog.we-online.com/em/datasheet/9775106960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775106960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-3.2mm_H11.6mm_ReverseMount_9775116960 +Mounting Hardware, inside through hole 3.2mm, height 11.6, Wuerth electronics 9775116960 (https://katalog.we-online.com/em/datasheet/9775116960.pdf), generated with kicad-footprint-generator +Mounting 3.2mm 9775116960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H2.6mm_ReverseMount_9775026360 +Mounting Hardware, inside through hole M3, height 2.6, Wuerth electronics 9775026360 (https://katalog.we-online.com/em/datasheet/9775026360.pdf), generated with kicad-footprint-generator +Mounting M3 9775026360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H3.1mm_ReverseMount_9775031360 +Mounting Hardware, inside through hole M3, height 3.1, Wuerth electronics 9775031360 (https://katalog.we-online.com/em/datasheet/9775031360.pdf), generated with kicad-footprint-generator +Mounting M3 9775031360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H3.6mm_ReverseMount_9775036360 +Mounting Hardware, inside through hole M3, height 3.6, Wuerth electronics 9775036360 (https://katalog.we-online.com/em/datasheet/9775036360.pdf), generated with kicad-footprint-generator +Mounting M3 9775036360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H4.1mm_ReverseMount_9775041360 +Mounting Hardware, inside through hole M3, height 4.1, Wuerth electronics 9775041360 (https://katalog.we-online.com/em/datasheet/9775041360.pdf), generated with kicad-footprint-generator +Mounting M3 9775041360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H4.6mm_ReverseMount_9775046360 +Mounting Hardware, inside through hole M3, height 4.6, Wuerth electronics 9775046360 (https://katalog.we-online.com/em/datasheet/9775046360.pdf), generated with kicad-footprint-generator +Mounting M3 9775046360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H5.1mm_ReverseMount_9775051360 +Mounting Hardware, inside through hole M3, height 5.1, Wuerth electronics 9775051360 (https://katalog.we-online.com/em/datasheet/9775051360.pdf), generated with kicad-footprint-generator +Mounting M3 9775051360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H5.6mm_ReverseMount_9775056360 +Mounting Hardware, inside through hole M3, height 5.6, Wuerth electronics 9775056360 (https://katalog.we-online.com/em/datasheet/9775056360.pdf), generated with kicad-footprint-generator +Mounting M3 9775056360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H6.6mm_ReverseMount_9775066360 +Mounting Hardware, inside through hole M3, height 6.6, Wuerth electronics 9775066360 (https://katalog.we-online.com/em/datasheet/9775066360.pdf), generated with kicad-footprint-generator +Mounting M3 9775066360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H7.6mm_ReverseMount_9775076360 +Mounting Hardware, inside through hole M3, height 7.6, Wuerth electronics 9775076360 (https://katalog.we-online.com/em/datasheet/9775076360.pdf), generated with kicad-footprint-generator +Mounting M3 9775076360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H8.6mm_ReverseMount_9775086360 +Mounting Hardware, inside through hole M3, height 8.6, Wuerth electronics 9775086360 (https://katalog.we-online.com/em/datasheet/9775086360.pdf), generated with kicad-footprint-generator +Mounting M3 9775086360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H9.6mm_ReverseMount_9775096360 +Mounting Hardware, inside through hole M3, height 9.6, Wuerth electronics 9775096360 (https://katalog.we-online.com/em/datasheet/9775096360.pdf), generated with kicad-footprint-generator +Mounting M3 9775096360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H10.6mm_ReverseMount_9775106360 +Mounting Hardware, inside through hole M3, height 10.6, Wuerth electronics 9775106360 (https://katalog.we-online.com/em/datasheet/9775106360.pdf), generated with kicad-footprint-generator +Mounting M3 9775106360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSR-M3_H11.6mm_ReverseMount_9775116360 +Mounting Hardware, inside through hole M3, height 11.6, Wuerth electronics 9775116360 (https://katalog.we-online.com/em/datasheet/9775116360.pdf), generated with kicad-footprint-generator +Mounting M3 9775116360 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H2.5mm_SnapRivet_9776025960 +Mounting Hardware, inside through hole 3.3mm, height 2.5, Wuerth electronics 9776025960 (https://katalog.we-online.com/em/datasheet/9776025960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776025960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H2mm_SnapRivet_9776020960 +Mounting Hardware, inside through hole 3.3mm, height 2, Wuerth electronics 9776020960 (https://katalog.we-online.com/em/datasheet/9776020960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776020960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H3mm_SnapRivet_9776030960 +Mounting Hardware, inside through hole 3.3mm, height 3, Wuerth electronics 9776030960 (https://katalog.we-online.com/em/datasheet/9776030960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776030960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H4mm_SnapRivet_9776040960 +Mounting Hardware, inside through hole 3.3mm, height 4, Wuerth electronics 9776040960 (https://katalog.we-online.com/em/datasheet/9776040960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776040960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H5mm_SnapRivet_9776050960 +Mounting Hardware, inside through hole 3.3mm, height 5, Wuerth electronics 9776050960 (https://katalog.we-online.com/em/datasheet/9776050960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776050960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H6mm_SnapRivet_9776060960 +Mounting Hardware, inside through hole 3.3mm, height 6, Wuerth electronics 9776060960 (https://katalog.we-online.com/em/datasheet/9776060960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776060960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H7mm_SnapRivet_9776070960 +Mounting Hardware, inside through hole 3.3mm, height 7, Wuerth electronics 9776070960 (https://katalog.we-online.com/em/datasheet/9776070960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776070960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H8mm_SnapRivet_9776080960 +Mounting Hardware, inside through hole 3.3mm, height 8, Wuerth electronics 9776080960 (https://katalog.we-online.com/em/datasheet/9776080960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776080960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H9mm_SnapRivet_9776090960 +Mounting Hardware, inside through hole 3.3mm, height 9, Wuerth electronics 9776090960 (https://katalog.we-online.com/em/datasheet/9776090960.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776090960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMSSR-3.3mm_H10mm_SnapRivet_9776100960 +Mounting Hardware, inside through hole 3.3mm, height 10, Wuerth electronics 9776100960 (https://katalog.we-online.com/em/datasheet/9776100960R.pdf), generated with kicad-footprint-generator +Mounting 3.3mm 9776100960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H1.5mm_9774015951 +Mounting Hardware, inside through hole 2.7mm, height 1.5, Wuerth electronics 9774015951 (https://katalog.we-online.de/em/datasheet/9774015951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774015951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H1mm_9774010951 +Mounting Hardware, inside through hole 2.7mm, height 1, Wuerth electronics 9774010951 (https://katalog.we-online.de/em/datasheet/9774010951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774010951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H2.5mm_9774025951 +Mounting Hardware, inside through hole 2.7mm, height 2.5, Wuerth electronics 9774025951 (https://katalog.we-online.de/em/datasheet/9774025951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774025951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H2mm_9774020951 +Mounting Hardware, inside through hole 2.7mm, height 2, Wuerth electronics 9774020951 (https://katalog.we-online.de/em/datasheet/9774020951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774020951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H3mm_9774030951 +Mounting Hardware, inside through hole 2.7mm, height 3, Wuerth electronics 9774030951 (https://katalog.we-online.de/em/datasheet/9774030951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774030951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H4mm_9774040951 +Mounting Hardware, inside through hole 2.7mm, height 4, Wuerth electronics 9774040951 (https://katalog.we-online.de/em/datasheet/9774040951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774040951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H5.5mm_9774055951 +Mounting Hardware, inside through hole 2.7mm, height 5.5, Wuerth electronics 9774055951 (https://katalog.we-online.de/em/datasheet/9774055951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774055951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H5mm_9774050951 +Mounting Hardware, inside through hole 2.7mm, height 5, Wuerth electronics 9774050951 (https://katalog.we-online.de/em/datasheet/9774050951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774050951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H6.5mm_9774065951 +Mounting Hardware, inside through hole 2.7mm, height 6.5, Wuerth electronics 9774065951 (https://katalog.we-online.de/em/datasheet/9774065951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774065951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H6mm_9774060951 +Mounting Hardware, inside through hole 2.7mm, height 6, Wuerth electronics 9774060951 (https://katalog.we-online.de/em/datasheet/9774060951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774060951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H7mm_9774070951 +Mounting Hardware, inside through hole 2.7mm, height 7, Wuerth electronics 9774070951 (https://katalog.we-online.de/em/datasheet/9774070951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774070951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H8mm_9774080951 +Mounting Hardware, inside through hole 2.7mm, height 8, Wuerth electronics 9774080951 (https://katalog.we-online.de/em/datasheet/9774080951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774080951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H9mm_9774090951 +Mounting Hardware, inside through hole 2.7mm, height 9, Wuerth electronics 9774090951 (https://katalog.we-online.de/em/datasheet/9774090951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774090951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.7mm_H10mm_9774100951 +Mounting Hardware, inside through hole 2.7mm, height 10, Wuerth electronics 9774100951 (https://katalog.we-online.de/em/datasheet/9774100951.pdf), generated with kicad-footprint-generator +Mounting 2.7mm 9774100951 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H1.5mm_9774015943 +Mounting Hardware, inside through hole 2.25mm, height 1.5, Wuerth electronics 9774015943 (https://katalog.we-online.de/em/datasheet/9774015943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774015943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H1mm_9774010943 +Mounting Hardware, inside through hole 2.25mm, height 1, Wuerth electronics 9774010943 (https://katalog.we-online.de/em/datasheet/9774010943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774010943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H2.5mm_9774025943 +Mounting Hardware, inside through hole 2.25mm, height 2.5, Wuerth electronics 9774025943 (https://katalog.we-online.de/em/datasheet/9774025943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774025943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H2mm_9774020943 +Mounting Hardware, inside through hole 2.25mm, height 2, Wuerth electronics 9774020943 (https://katalog.we-online.de/em/datasheet/9774020943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774020943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H3.5mm_9774035943 +Mounting Hardware, inside through hole 2.25mm, height 3.5, Wuerth electronics 9774035943 (https://katalog.we-online.de/em/datasheet/9774035943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774035943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H3mm_9774030943 +Mounting Hardware, inside through hole 2.25mm, height 3, Wuerth electronics 9774030943 (https://katalog.we-online.de/em/datasheet/9774030943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774030943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H4.5mm_9774045943 +Mounting Hardware, inside through hole 2.25mm, height 4.5, Wuerth electronics 9774045943 (https://katalog.we-online.de/em/datasheet/9774045943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774045943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H4mm_9774040943 +Mounting Hardware, inside through hole 2.25mm, height 4, Wuerth electronics 9774040943 (https://katalog.we-online.de/em/datasheet/9774040943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774040943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H5mm_9774050943 +Mounting Hardware, inside through hole 2.25mm, height 5, Wuerth electronics 9774050943 (https://katalog.we-online.de/em/datasheet/9774050943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774050943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H6mm_9774060943 +Mounting Hardware, inside through hole 2.25mm, height 6, Wuerth electronics 9774060943 (https://katalog.we-online.de/em/datasheet/9774060943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774060943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H7mm_9774070943 +Mounting Hardware, inside through hole 2.25mm, height 7, Wuerth electronics 9774070943 (https://katalog.we-online.de/em/datasheet/9774070943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774070943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-2.25mm_H8mm_9774080943 +Mounting Hardware, inside through hole 2.25mm, height 8, Wuerth electronics 9774080943 (https://katalog.we-online.de/em/datasheet/9774080943.pdf), generated with kicad-footprint-generator +Mounting 2.25mm 9774080943 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H1.5mm_9774015960 +Mounting Hardware, inside through hole 3.3mm, height 1.5, Wuerth electronics 9774015960 (https://katalog.we-online.de/em/datasheet/9774015960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774015960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H1mm_9774010960 +Mounting Hardware, inside through hole 3.3mm, height 1, Wuerth electronics 9774010960 (https://katalog.we-online.de/em/datasheet/9774010960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774010960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H2.5mm_9774025960 +Mounting Hardware, inside through hole 3.3mm, height 2.5, Wuerth electronics 9774025960 (https://katalog.we-online.de/em/datasheet/9774025960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774025960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H2mm_9774020960 +Mounting Hardware, inside through hole 3.3mm, height 2, Wuerth electronics 9774020960 (https://katalog.we-online.de/em/datasheet/9774020960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774020960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H3mm_9774030960 +Mounting Hardware, inside through hole 3.3mm, height 3, Wuerth electronics 9774030960 (https://katalog.we-online.de/em/datasheet/9774030960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774030960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H4mm_9774040960 +Mounting Hardware, inside through hole 3.3mm, height 4, Wuerth electronics 9774040960 (https://katalog.we-online.de/em/datasheet/9774040960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774040960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H5mm_9774050960 +Mounting Hardware, inside through hole 3.3mm, height 5, Wuerth electronics 9774050960 (https://katalog.we-online.de/em/datasheet/9774050960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774050960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H6mm_9774060960 +Mounting Hardware, inside through hole 3.3mm, height 6, Wuerth electronics 9774060960 (https://katalog.we-online.de/em/datasheet/9774060960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774060960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H7mm_9774070960 +Mounting Hardware, inside through hole 3.3mm, height 7, Wuerth electronics 9774070960 (https://katalog.we-online.de/em/datasheet/9774070960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774070960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H8mm_9774080960 +Mounting Hardware, inside through hole 3.3mm, height 8, Wuerth electronics 9774080960 (https://katalog.we-online.de/em/datasheet/9774080960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774080960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H9mm_9774090960 +Mounting Hardware, inside through hole 3.3mm, height 9, Wuerth electronics 9774090960 (https://katalog.we-online.de/em/datasheet/9774090960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774090960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H10mm_9774100960 +Mounting Hardware, inside through hole 3.3mm, height 10, Wuerth electronics 9774100960 (https://katalog.we-online.de/em/datasheet/9774100960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774100960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H11mm_9774110960 +Mounting Hardware, inside through hole 3.3mm, height 11, Wuerth electronics 9774110960 (https://katalog.we-online.de/em/datasheet/9774110960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774110960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H12mm_9774120960 +Mounting Hardware, inside through hole 3.3mm, height 12, Wuerth electronics 9774120960 (https://katalog.we-online.de/em/datasheet/9774120960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774120960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H13mm_9774130960 +Mounting Hardware, inside through hole 3.3mm, height 13, Wuerth electronics 9774130960 (https://katalog.we-online.de/em/datasheet/9774130960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774130960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H14mm_9774140960 +Mounting Hardware, inside through hole 3.3mm, height 14, Wuerth electronics 9774140960 (https://katalog.we-online.de/em/datasheet/9774140960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774140960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-3.3mm_H15mm_9774150960 +Mounting Hardware, inside through hole 3.3mm, height 15, Wuerth electronics 9774150960 (https://katalog.we-online.de/em/datasheet/9774150960.pdf,), generated with kicad-footprint-generator +Mounting 3.3mm 9774150960 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H1mm_9774010982 +Mounting Hardware, inside through hole 4.5mm, height 1, Wuerth electronics 9774010982 (https://katalog.we-online.de/em/datasheet/9774010982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774010982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H2mm_9774020982 +Mounting Hardware, inside through hole 4.5mm, height 2, Wuerth electronics 9774020982 (https://katalog.we-online.de/em/datasheet/9774020982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774020982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H3mm_9774030982 +Mounting Hardware, inside through hole 4.5mm, height 3, Wuerth electronics 9774030982 (https://katalog.we-online.de/em/datasheet/9774030982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774030982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H4mm_9774040982 +Mounting Hardware, inside through hole 4.5mm, height 4, Wuerth electronics 9774040982 (https://katalog.we-online.de/em/datasheet/9774040982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774040982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H5mm_9774050982 +Mounting Hardware, inside through hole 4.5mm, height 5, Wuerth electronics 9774050982 (https://katalog.we-online.de/em/datasheet/9774050982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774050982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H6mm_9774060982 +Mounting Hardware, inside through hole 4.5mm, height 6, Wuerth electronics 9774060982 (https://katalog.we-online.de/em/datasheet/9774060982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774060982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H7mm_9774070982 +Mounting Hardware, inside through hole 4.5mm, height 7, Wuerth electronics 9774070982 (https://katalog.we-online.de/em/datasheet/9774070982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774070982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H8mm_9774080982 +Mounting Hardware, inside through hole 4.5mm, height 8, Wuerth electronics 9774080982 (https://katalog.we-online.de/em/datasheet/9774080982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774080982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H9mm_9774090982 +Mounting Hardware, inside through hole 4.5mm, height 9, Wuerth electronics 9774090982 (https://katalog.we-online.de/em/datasheet/9774090982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774090982 +0 +8 +1 +Mounting_Wuerth +Mounting_Wuerth_WA-SMST-4.5mm_H10mm_9774100982 +Mounting Hardware, inside through hole 4.5mm, height 10, Wuerth electronics 9774100982 (https://katalog.we-online.de/em/datasheet/9774100982.pdf), generated with kicad-footprint-generator +Mounting 4.5mm 9774100982 +0 +8 +1 +NetTie +NetTie-2_SMD_Pad0.5mm +Net tie, 2 pin, 0.5mm square SMD pads +net tie +0 +2 +2 +NetTie +NetTie-2_SMD_Pad2.0mm +Net tie, 2 pin, 2.0mm square SMD pads +net tie +0 +2 +2 +NetTie +NetTie-2_THT_Pad0.3mm +Net tie, 2 pin, 0.3mm round THT pads +net tie +0 +2 +2 +NetTie +NetTie-2_THT_Pad1.0mm +Net tie, 2 pin, 1.0mm round THT pads +net tie +0 +2 +2 +NetTie +NetTie-3_SMD_Pad0.5mm +Net tie, 3 pin, 0.5mm square SMD pads +net tie +0 +3 +3 +NetTie +NetTie-3_SMD_Pad2.0mm +Net tie, 3 pin, 2.0mm square SMD pads +net tie +0 +3 +3 +NetTie +NetTie-3_THT_Pad0.3mm +Net tie, 3 pin, 0.3mm round THT pads +net tie +0 +3 +3 +NetTie +NetTie-3_THT_Pad1.0mm +Net tie, 3 pin, 1.0mm round THT pads +net tie +0 +3 +3 +NetTie +NetTie-4_SMD_Pad0.5mm +Net tie, 4 pin, 0.5mm square SMD pads +net tie +0 +4 +4 +NetTie +NetTie-4_SMD_Pad2.0mm +Net tie, 4 pin, 2.0mm square SMD pads +net tie +0 +4 +4 +NetTie +NetTie-4_THT_Pad0.3mm +Net tie, 4 pin, 0.3mm round THT pads +net tie +0 +4 +4 +NetTie +NetTie-4_THT_Pad1.0mm +Net tie, 4 pin, 1.0mm round THT pads +net tie +0 +4 +4 +OptoDevice +ADNS-9800 +Laser Gaming Sensor ADNS-9800 +MOUSE MOUSE_SENSOR LASER_GAMING_SENSOR +0 +16 +16 +OptoDevice +AGILENT_HFBR-152x +Fiberoptic Transmitter TX, HFBR series (https://docs.broadcom.com/docs/AV02-3283EN) +Fiberoptic Transmitter +0 +6 +6 +OptoDevice +AGILENT_HFBR-252x +Fiberoptic Receiver RX, HFBR series (https://docs.broadcom.com/docs/AV02-3283EN) +Fiberoptic Transmitter +0 +6 +6 +OptoDevice +AMS_TSL2550_SMD +http://ams.com/eng/content/download/250130/975613/142977 +TSL2550 ambient light sensor +0 +4 +4 +OptoDevice +Broadcom_AFBR-16xxZ_Horizontal +Fiber Optic Transmitter and Receiver, https://docs.broadcom.com/docs/AV02-4369EN +Fiber Optic Transmitter and Receiver +0 +6 +6 +OptoDevice +Broadcom_AFBR-16xxZ_Tilted +Fiber Optic Transmitter and Receiver, https://docs.broadcom.com/docs/AV02-4369EN +Fiber Optic Transmitter and Receiver +0 +6 +6 +OptoDevice +Broadcom_AFBR-16xxZ_Vertical +Fiber Optic Transmitter and Receiver, https://docs.broadcom.com/docs/AV02-4369EN +Fiber Optic Transmitter and Receiver +0 +6 +6 +OptoDevice +Broadcom_APDS-9301 +ambient light sensor, i2c interface, 6-pin chipled package, https://docs.broadcom.com/docs/AV02-2315EN +ambient light sensor chipled +0 +6 +6 +OptoDevice +Broadcom_DFN-6_2x2mm_P0.65mm +Broadcom DFN, 6 Pin (https://docs.broadcom.com/docs/AV02-4755EN), generated with kicad-footprint-generator ipc_noLead_generator.py +Broadcom DFN NoLead +0 +6 +6 +OptoDevice +Broadcom_LGA-8_2x2mm_P0.53mm +Broadcom LGA, 8 Pin (https://docs.broadcom.com/docs/AV02-4755EN), generated with kicad-footprint-generator ipc_noLead_generator.py +Broadcom LGA NoLead +0 +8 +8 +OptoDevice +Everlight_ITR1201SR10AR +package for Everlight ITR1201SR10AR, light-direction upwards, see https://www.everlight.com/file/ProductFile/ITR1201SR10AR-TR.pdf +reflective opto couple photo coupler +0 +4 +4 +OptoDevice +Everlight_ITR8307 +package for Everlight ITR8307 with PCB cutout, light-direction upwards, see http://www.everlight.com/file/ProductFile/ITR8307.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Everlight_ITR8307F43 +package for Everlight ITR8307/F43, see https://everlighteurope.com/index.php?controller=attachment&id_attachment=5385 +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Everlight_ITR8307_Reverse +package for Everlight ITR8307 with PCB cutout, light-direction downwards, see http://www.everlight.com/file/ProductFile/ITR8307.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Finder_34.81 +Relay SPST, Finder Type 34.81 (opto relays/coupler), vertical/standing form, see https://gfinder.findernet.com/public/attachments/34/EN/S34USAEN.pdf +Relay SPST Finder +0 +4 +4 +OptoDevice +Hamamatsu_C12880 +Hamamatsu spectrometer, see http://www.hamamatsu.com/resources/pdf/ssd/c12880ma_kacc1226e.pdf +opto spectrometer Hamamatsu +0 +10 +10 +OptoDevice +Hamamatsu_S13360-30CS +SiPM, 2pin +Hamamatsu SiPM +0 +2 +2 +OptoDevice +Kingbright_KPS-5130 +http://www.kingbright.com/attachments/file/psearch/000/00/00/KPS-5130PD7C(Ver.14).pdf +KPS-5130 photodiode RGB sensor +0 +4 +4 +OptoDevice +Kingbright_KRC011_Horizontal +Subminiature Reflective Optical Sensor, http://www.kingbright.com/attachments/file/psearch/000/00/00/KRC011(Ver.15).pdf +Subminiature Reflective Optical Sensor +0 +4 +4 +OptoDevice +Kingbright_KRC011_Vertical +Subminiature Reflective Optical Sensor, http://www.kingbright.com/attachments/file/psearch/000/00/00/KRC011(Ver.15).pdf +Subminiature Reflective Optical Sensor +0 +4 +4 +OptoDevice +Kodenshi_LG206D +http://kodenshi.co.jp/products/pdf/sensor/photointerrupter_ic/LG206D.pdf +Photointerrupter infrared LED with photo IC +0 +5 +5 +OptoDevice +Kodenshi_LG206L +http://kodenshi.co.jp/products/pdf/sensor/photointerrupter_ic/LG205L.pdf +Photointerrupter infrared LED with photo IC +0 +5 +5 +OptoDevice +Kodenshi_SG105 +package for Kodenshi SG-105 with PCB cutout, light-direction upwards, see http://www.kodenshi.co.jp/products/pdf/sensor/photointerrupter_ref/SG-105.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Kodenshi_SG105F +package for Kodenshi SG-105F, see http://www.kodenshi.co.jp/products/pdf/sensor/photointerrupter_ref/SG-105F.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Kodenshi_SG105_Reverse +package for Kodenshi SG-105 with PCB cutout, light-direction downwards, see http://www.kodenshi.co.jp/products/pdf/sensor/photointerrupter_ref/SG-105.pdf +refective opto couple photo coupler +0 +4 +4 +OptoDevice +LaserDiode_TO3.3-D3.3-3 +Laser Diode, TO-3.3mm, 3pin +Laser Diode TO3.3 +0 +3 +3 +OptoDevice +LaserDiode_TO5-D9-3 +Laser Diode, TO5-like (D=9mm), 3pin +Laser Diode TO5-like +0 +3 +3 +OptoDevice +LaserDiode_TO18-D5.6-3 +Laser Diode, TO18-like (D=5.6mm), 3pin +Laser Diode TO18-like +0 +3 +3 +OptoDevice +LaserDiode_TO38ICut-3 +Laser Diode, TO-38-ICut, 3pin +Laser Diode TO38-ICut +0 +3 +3 +OptoDevice +LaserDiode_TO56-3 +Laser Diode, TO-56, 3pin +Laser Diode TO56 +0 +3 +3 +OptoDevice +Lightpipe_LPF-C012303S +https://www.lumex.com/spec/LPF-C012303S.pdf +lightpipe dual tower right angle 3mm +0 +0 +0 +OptoDevice +Lightpipe_Mentor_1275.x00x +https://www.mentor-bauelemente.de/katalog/ll/MENTOR-LL.pdf +spherical light pipe 4 way 3mm PLCC-2 PLCC-4 +0 +0 +0 +OptoDevice +Lightpipe_Mentor_1276.1004 +https://www.mentor-bauelemente.de/katalog/ll/MENTOR-LL.pdf +spherical light pipe 4 way 3mm PLCC-2 PLCC-4 +0 +0 +0 +OptoDevice +Lightpipe_Mentor_1276.2004 +https://www.mentor-bauelemente.de/katalog/ll/MENTOR-LL.pdf +planar light pipe 4 way 3mm PLCC-2 PLCC-4 +0 +0 +0 +OptoDevice +Lite-On_LTR-303ALS-01 +ambient light sensor, i2c interface, 6-pin chipled package, http://optoelectronics.liteon.com/upload/download/DS86-2013-0004/LTR-303ALS-01_DS_V1.pdf +ambient light sensor chipled +0 +6 +6 +OptoDevice +Luna_NSL-32 +Optoisolator with LED and photoresistor +optoisolator +0 +4 +4 +OptoDevice +Maxim_OLGA-14_3.3x5.6mm_P0.8mm +https://pdfserv.maximintegrated.com/land_patterns/90-0602.PDF +OLGA-14 OESIP-14 +0 +14 +14 +OptoDevice +ONSemi_QSE15x +3 Lead Plastic Package +ONSemi QSE158 QSE159 +0 +3 +3 +OptoDevice +OnSemi_CASE100AQ +OnSemi CASE 100AQ for QRE1113, see https://www.onsemi.com/pub/Collateral/QRE1113-D.PDF +reflective opto couple photo coupler +0 +4 +4 +OptoDevice +OnSemi_CASE100CY +OnSemi CASE 100CY, light-direction upwards, see http://www.onsemi.com/pub/Collateral/QRE1113-D.PDF +refective opto couple photo coupler +0 +4 +4 +OptoDevice +Osram_BPW82 +PhotoDiode, BPW82, RM2.54 +PhotoDiode BPW82 RM2.54 +0 +2 +2 +OptoDevice +Osram_DIL2_4.3x4.65mm_P5.08mm +PhotoDiode, plastic DIL, 4.3x4.65mm², RM5.08 +PhotoDiode plastic DIL RM5.08 +0 +2 +2 +OptoDevice +Osram_LPT80A +PhotoTransistor, sidelooker package, RM2.54 +PhotoTransistor sidelooker package RM2.54 +0 +2 +2 +OptoDevice +Osram_SFH9x0x +package for Osram SFH9x0x series of reflective photo interrupters/couplers, see http://www.osram-os.com/Graphics/XPic6/00200860_0.pdf +reflective photo interrupter SMD +0 +6 +6 +OptoDevice +Osram_SFH205 +PhotoDiode, SFH205, RM2.54 +PhotoDiode SFH205 RM2.54 +0 +2 +2 +OptoDevice +Osram_SFH225 +PhotoDiode, SFH225, RM2.54 +PhotoDiode SFH225 RM2.54 +0 +2 +2 +OptoDevice +Osram_SMD-DIL2_4.5x4.0mm +PhotoDiode, plastic SMD DIL, 4.5x4mm² +PhotoDiode plastic SMD DIL +0 +2 +2 +OptoDevice +Osram_SMD-SmartDIL +PhotoDiode, plastic SMD SmatDIL +PhotoDiode plastic SMD SmatDIL +0 +3 +3 +OptoDevice +Panasonic_APV-AQY_SSOP-4_4.45x2.65mm_P1.27mm +https://www.panasonic-electric-works.com/cps/rde/xbcr/pew_eu_en/technical_information_photomos_en.pdf +SSOP4 APV21 AQY22 +0 +4 +4 +OptoDevice +PerkinElmer_VTL5C +Axial Vactrol (http://www.qsl.net/wa1ion/vactrol/vactrol.pdf) +vactrol +0 +4 +4 +OptoDevice +PerkinElmer_VTL5Cx2 +Axial Vactrol (http://www.qsl.net/wa1ion/vactrol/vactrol.pdf) +vactrol +0 +5 +5 +OptoDevice +R_LDR_4.9x4.2mm_P2.54mm_Vertical +Resistor, LDR 4.9x4.2mm +Resistor LDR4.9x4.2 +0 +2 +2 +OptoDevice +R_LDR_5.0x4.1mm_P3mm_Vertical +Resistor, LDR 5x4.1mm, see http://cdn-reichelt.de/documents/datenblatt/A500/A90xxxx%23PE.pdf +Resistor LDR5x4.1mm +0 +2 +2 +OptoDevice +R_LDR_5.1x4.3mm_P3.4mm_Vertical +Resistor, LDR 5.1x3.4mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR5.1x3.4mm +0 +2 +2 +OptoDevice +R_LDR_5.2x5.2mm_P3.5mm_Horizontal +Resistor, LDR 5.2x5.2, upright, see http://cdn-reichelt.de/documents/datenblatt/A500/M996011A.pdf +Resistor LDR5.2x5.2 +0 +2 +2 +OptoDevice +R_LDR_7x6mm_P5.1mm_Vertical +Resistor, LDR 7x6mm +Resistor LDR7x6mm +0 +2 +2 +OptoDevice +R_LDR_10x8.5mm_P7.6mm_Vertical +Resistor, LDR 10x8.5mm +Resistor LDR10.8.5mm +0 +2 +2 +OptoDevice +R_LDR_11x9.4mm_P8.2mm_Vertical +Resistor, LDR 11x9.4mm +Resistor LDR11x9.4mm +0 +2 +2 +OptoDevice +R_LDR_12x10.8mm_P9.0mm_Vertical +Resistor, LDR 12x10.8mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR12x10.8mm +0 +2 +2 +OptoDevice +R_LDR_D6.4mm_P3.4mm_Vertical +Resistor, LDR D=6.4mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDRD=6.4mm +0 +2 +2 +OptoDevice +R_LDR_D13.8mm_P9.0mm_Vertical +Resistor, diameter 13.8mm pitch 9mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR +0 +2 +2 +OptoDevice +R_LDR_D20mm_P17.5mm_Vertical +Resistor, LDR 20mm diameter, pin pitch 17.5mm, see http://yourduino.com/docs/Photoresistor-5516-datasheet.pdf +Resistor LDR +0 +2 +2 +OptoDevice +ST_VL53L0X +https://www.st.com/resource/en/datasheet/vl53l1x.pdf +laser-ranging sensor +0 +12 +12 +OptoDevice +ST_VL53L1X +https://www.st.com/resource/en/datasheet/vl53l1x.pdf +laser-ranging sensor +0 +12 +12 +OptoDevice +Sharp_GP2Y0A41SK0F +http://www.sharp-world.com/products/device/lineup/data/pdf/datasheet/gp2y0a41sk_e.pdf +Distance Sensor Sharp +0 +2 +2 +OptoDevice +Sharp_IS471F +Sharp OPIC IS471F, see http://pdf.datasheetcatalog.com/datasheet/Sharp/mXvrzty.pdf +Sharp OPIC IS471F +0 +4 +4 +OptoDevice +Sharp_IS485 +Sharp OPIC, IS485, IS486, see http://microrato.ua.pt/main/Actividades/Estagios/Docs/IS485_6.pdf +Sharp OPIC IS485 IS486 +0 +3 +3 +OptoDevice +Siemens_SFH900 +package for Siemens SFH900 reflex photo interrupter/coupler/object detector, see https://www.batronix.com/pdf/sfh900.pdf +Siemens SFH900 reflex photo interrupter coupler object detector +0 +3 +3 +OptoDevice +Toshiba_TORX170_TORX173_TORX193_TORX194 +Fiberoptic Reciver, RX, Toshiba, Toslink, TORX170, TORX173, TORX193, TORX194 +Fiberoptic Reciver RX Toshiba Toslink TORX170 TORX173 TORX193 TORX194 +0 +6 +6 +OptoDevice +Toshiba_TOTX170_TOTX173_TOTX193_TOTX194 +Fiberoptic Reciver, RX, Toshiba, Toslink, TORX170, TORX173, TORX193, TORX194 +Fiberoptic Reciver RX Toshiba Toslink TORX170 TORX173 TORX193 TORX194 +0 +6 +6 +OptoDevice +Vishay_CAST-3Pin +IR Receiver Vishay TSOP-xxxx, CAST package, see https://www.vishay.com/docs/82493/tsop311.pdf +IRReceiverVishayTSOP-xxxx CAST +0 +3 +3 +OptoDevice +Vishay_CNY70 +package for Vishay CNY70 refective photo coupler/interrupter +Vishay CNY70 refective photo coupler +0 +4 +4 +OptoDevice +Vishay_MINICAST-3Pin +IR Receiver Vishay TSOP-xxxx, MINICAST package, see https://www.vishay.com/docs/82669/tsop32s40f.pdf +IR Receiver Vishay TSOP-xxxx MINICAST +0 +3 +3 +OptoDevice +Vishay_MINIMOLD-3Pin +IR Receiver Vishay TSOP-xxxx, MINIMOLD package, see https://www.vishay.com/docs/82742/tsop331.pdf +IR Receiver Vishay TSOP-xxxx MINIMOLD +0 +3 +3 +OptoDevice +Vishay_MOLD-3Pin +IR Receiver Vishay TSOP-xxxx, MOLD package, see https://www.vishay.com/docs/82669/tsop32s40f.pdf +IR Receiver Vishay TSOP-xxxx MOLD +0 +3 +3 +Oscillator +Oscillator_DIP-8 +Oscillator, DIP8,http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_DIP-8_LargePads +Oscillator, DIP8, Large Pads, http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_DIP-14 +Oscillator, DIP14, http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_DIP-14_LargePads +Oscillator, DIP14, Large Pads, http://cdn-reichelt.de/documents/datenblatt/B400/OSZI.pdf +oscillator +0 +4 +4 +Oscillator +Oscillator_OCXO_Morion_MV267 +http://www.morion.com.ru/catalog_pdf/MV267.pdf +OCXO +0 +5 +5 +Oscillator +Oscillator_OCXO_Morion_MV317 +https://www.morion-us.com/catalog_pdf/mv317.pdf +OCXO +0 +5 +5 +Oscillator +Oscillator_SMD_Abracon_ABLNO +https://abracon.com/Precisiontiming/ABLNO.pdf +VCXO XO +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASCO-4Pin_1.6x1.2mm +Miniature Crystal Clock Oscillator Abracon ASCO series, https://abracon.com/Oscillators/ASCO.pdf, 1.6x1.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASDMB-4Pin_2.5x2.0mm +Miniature Crystal Clock Oscillator Abracon ASDMB series, 2.5x2.0mm package, http://www.abracon.com/Oscillators/ASDMB.pdf +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASE-4Pin_3.2x2.5mm +Miniature Crystal Clock Oscillator Abracon ASE series, http://www.abracon.com/Oscillators/ASEseries.pdf, 3.2x2.5mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASE-4Pin_3.2x2.5mm_HandSoldering +Miniature Crystal Clock Oscillator Abracon ASE series, http://www.abracon.com/Oscillators/ASEseries.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASV-4Pin_7.0x5.1mm +Miniature Crystal Clock Oscillator Abracon ASV series, http://www.abracon.com/Oscillators/ASV.pdf, 7.0x5.1mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Abracon_ASV-4Pin_7.0x5.1mm_HandSoldering +Miniature Crystal Clock Oscillator Abracon ASV series, http://www.abracon.com/Oscillators/ASV.pdf, hand-soldering, 7.0x5.1mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Diodes_FN-4Pin_7.0x5.0mm +FN Series Crystal Clock Oscillator (XO) (https://www.diodes.com/assets/Datasheets/FN_3-3V.pdf) +Oscillator Crystal SMD SMT +0 +4 +4 +Oscillator +Oscillator_SMD_ECS_2520MV-xxx-xx-4Pin_2.5x2.0mm +Miniature Crystal Clock Oscillator ECS 2520MV series, https://www.ecsxtal.com/store/pdf/ECS-2520MV.pdf +Miniature Crystal Clock Oscillator ECS 2520MV series SMD SMT HCMOS +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO32-4Pin_3.2x2.5mm +Miniature Crystal Clock Oscillator EuroQuartz XO32 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO32.pdf, 3.2x2.5mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO32-4Pin_3.2x2.5mm_HandSoldering +Miniature Crystal Clock Oscillator EuroQuartz XO32 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO32.pdf, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO53-4Pin_5.0x3.2mm +Miniature Crystal Clock Oscillator EuroQuartz XO53 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO53.pdf, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO53-4Pin_5.0x3.2mm_HandSoldering +Miniature Crystal Clock Oscillator EuroQuartz XO53 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO53.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO91-4Pin_7.0x5.0mm +Miniature Crystal Clock Oscillator EuroQuartz XO91 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO91.pdf, 7.0x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_EuroQuartz_XO91-4Pin_7.0x5.0mm_HandSoldering +Miniature Crystal Clock Oscillator EuroQuartz XO91 series, http://cdn-reichelt.de/documents/datenblatt/B400/XO91.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS1-6Pin_14.8x9.1mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S1-KHZ/LHZ, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 14.8x9.1mm^2 package +SMD SMT crystal oscillator +0 +6 +6 +Oscillator +Oscillator_SMD_Fordahl_DFAS2-4Pin_7.3x5.1mm +Mminiature Crystal Clock Oscillator TXCO Fordahl DFA S2-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 7.3x5.1mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS2-4Pin_7.3x5.1mm_HandSoldering +Mminiature Crystal Clock Oscillator TXCO Fordahl DFA S2-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 7.3x5.1mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS3-4Pin_9.1x7.2mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S3-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 9.1x7.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS3-4Pin_9.1x7.2mm_HandSoldering +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S3-KS/LS/US, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 9.1x7.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS7-4Pin_19.9x12.9mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S7-K/L, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 19.9x12.9mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS7-4Pin_19.9x12.9mm_HandSoldering +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S7-K/L, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 19.9x12.9mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS11-4Pin_7.0x5.0mm +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S11-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 7.0x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS11-4Pin_7.0x5.0mm_HandSoldering +Miniature Crystal Clock Oscillator TXCO Fordahl DFA S11-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS15-4Pin_5.0x3.2mm +Ultraminiature Crystal Clock Oscillator TXCO Fordahl DFA S15-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_Fordahl_DFAS15-4Pin_5.0x3.2mm_HandSoldering +Ultraminiature Crystal Clock Oscillator TXCO Fordahl DFA S15-OV/UOV, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_IDT_JS6-6_5.0x3.2mm_P1.27mm +SMD Crystal Oscillator IDT https://www.idt.com/document/dst/xu-family-datasheet#page=15, 5.0x3.2mm +SMD SMT crystal oscillator +0 +6 +6 +Oscillator +Oscillator_SMD_IDT_JU6-6_7.0x5.0mm_P2.54mm +SMD Crystal Oscillator IDT https://www.idt.com/document/dst/xu-family-datasheet#page=17, 7.0x5.0mm +SMD SMT crystal oscillator +0 +6 +6 +Oscillator +Oscillator_SMD_IQD_IQXO70-4Pin_7.5x5.0mm +IQD Crystal Clock Oscillator IQXO-70, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, 7.5x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_IQD_IQXO70-4Pin_7.5x5.0mm_HandSoldering +IQD Crystal Clock Oscillator IQXO-70, http://www.iqdfrequencyproducts.com/products/details/iqxo-70-11-30.pdf, hand-soldering, 7.5x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Kyocera_2520-6Pin_2.5x2.0mm +https://global.kyocera.com/prdct/electro/product/pdf/kt2520_e.pdf +2.5mm 2mm SMD +0 +6 +6 +Oscillator +Oscillator_SMD_Kyocera_KC2520Z-4Pin_2.5x2.0mm +https://global.kyocera.com/prdct/electro/product/pdf/clock_z_xz_e.pdf +2.5mm 2mm SMD +0 +4 +4 +Oscillator +Oscillator_SMD_OCXO_ConnorWinfield_OH300 +http://www.conwin.com/datasheets/cx/cx282.pdf +OCXO +0 +7 +7 +Oscillator +Oscillator_SMD_SI570_SI571_HandSoldering +SI570, SI571, Programmable oscillator, Standard +SI570 SI571 Programmable oscillator Standard +0 +8 +8 +Oscillator +Oscillator_SMD_SI570_SI571_Standard +SI570, SI571, Programmable oscillator, Standard +SI570 SI571 Programmable oscillator Standard +0 +8 +8 +Oscillator +Oscillator_SMD_SeikoEpson_SG210-4Pin_2.5x2.0mm +SMD Crystal Oscillator Seiko Epson SG-210 https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-210SED, 2.5x2.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG210-4Pin_2.5x2.0mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-210 https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-210SED, hand-soldering, 2.5x2.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG3030CM +SMD Crystal Oscillator Seiko Epson SG-3030CM package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CA-4Pin_7.0x5.0mm +SMD Crystal Oscillator Seiko Epson SG-8002CA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 7.0x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CA-4Pin_7.0x5.0mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002CA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 7.0x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CE-4Pin_3.2x2.5mm +SMD Crystal Oscillator Seiko Epson SG-8002CE https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 3.2x2.5mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002CE-4Pin_3.2x2.5mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002CE https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 3.2x2.5mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JA-4Pin_14.0x8.7mm +SMD Crystal Oscillator Seiko Epson SG-8002JA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 14.0x8.7mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JA-4Pin_14.0x8.7mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002JA https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 14.0x8.7mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JC-4Pin_10.5x5.0mm +SMD Crystal Oscillator Seiko Epson SG-8002JC https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 10.5x5.0mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002JC-4Pin_10.5x5.0mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002JC https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 10.5x5.0mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002LB-4Pin_5.0x3.2mm +SMD Crystal Oscillator Seiko Epson SG-8002LB https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_SeikoEpson_SG8002LB-4Pin_5.0x3.2mm_HandSoldering +SMD Crystal Oscillator Seiko Epson SG-8002LB https://support.epson.biz/td/api/doc_check.php?mode=dl&lang=en&Parts=SG-8002DC, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SMD_Silicon_Labs_LGA-6_2.5x3.2mm_P1.25mm +Silicon_Labs LGA, 6 Pin (https://www.silabs.com/documents/public/data-sheets/si512-13.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Silicon_Labs LGA NoLead +0 +6 +6 +Oscillator +Oscillator_SMD_TCXO_G158 +TCXO +TCXO +0 +4 +4 +Oscillator +Oscillator_SMD_TXC_7C-4Pin_5.0x3.2mm +Miniature Crystal Clock Oscillator TXC 7C series, http://www.txccorp.com/download/products/osc/7C_o.pdf, 5.0x3.2mm^2 package +SMD SMT crystal oscillator +0 +4 +4 +Oscillator +Oscillator_SMD_TXC_7C-4Pin_5.0x3.2mm_HandSoldering +Miniature Crystal Clock Oscillator TXC 7C series, http://www.txccorp.com/download/products/osc/7C_o.pdf, hand-soldering, 5.0x3.2mm^2 package +SMD SMT crystal oscillator hand-soldering +0 +4 +4 +Oscillator +Oscillator_SeikoEpson_SG-8002DB +14-lead dip package, row spacing 7.62 mm (300 mils) +DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Oscillator +Oscillator_SeikoEpson_SG-8002DC +8-lead dip package, row spacing 7.62 mm (300 mils) +DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Package_BGA +Analog_BGA-28_4.0x6.25mm_Layout4x7_P0.8mm_Ball0.45mm_Pad0.4 +Analog BGA-28 4.0mm x 6.25mm package, pitch 0.4mm pad, based on https://www.analog.com/media/en/technical-documentation/data-sheets/8063fa.pdf +BGA 28 0.8 +0 +28 +28 +Package_BGA +BGA-9_1.6x1.6mm_Layout3x3_P0.5mm +BGA-9, http://www.ti.com/lit/ds/symlink/bq27421-g1.pdf +BGA-9 +0 +9 +9 +Package_BGA +BGA-16_1.92x1.92mm_Layout4x4_P0.5mm +BGA-16, http://www.st.com/content/ccc/resource/technical/document/datasheet/group2/bc/cd/62/9e/8f/30/47/69/CD00151267/files/CD00151267.pdf/jcr:content/translations/en.CD00151267.pdf +BGA-16 +0 +16 +16 +Package_BGA +BGA-25_6.35x6.35mm_Layout5x5_P1.27mm +BGA-25, http://cds.linear.com/docs/en/datasheet/4624fc.pdf +BGA-25 uModule +0 +25 +25 +Package_BGA +BGA-36_3.396x3.466mm_Layout6x6_P0.4mm_Ball0.25mm_Pad0.2mm_NSMD +Altera V36, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00486-00.pdf +Altera BGA-36 V36 VBGA +0 +36 +36 +Package_BGA +BGA-48_8.0x9.0mm_Layout6x8_P0.8mm +BGA-48 - pitch 0.8 mm +BGA-48 +0 +48 +48 +Package_BGA +BGA-64_9.0x9.0mm_Layout10x10_P0.8mm +BGA-64, 10x10 raster, 9x9mm package, pitch 0.8mm +BGA-64 +0 +64 +64 +Package_BGA +BGA-68_5.0x5.0mm_Layout9x9_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-68, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00344-01.pdf +Altera BGA-68 M68 MBGA +0 +68 +68 +Package_BGA +BGA-81_4.496x4.377mm_Layout9x9_P0.4mm_Ball0.25mm_Pad0.2mm_NSMD +Altera V81, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00478-01.pdf +Altera VBGA V81 BGA-81 +0 +81 +81 +Package_BGA +BGA-90_8.0x13.0mm_Layout2x3x15_P0.8mm +BGA-90, http://www.issi.com/WW/pdf/42-45S32800J.pdf +BGA-90 +0 +90 +90 +Package_BGA +BGA-96_9.0x13.0mm_Layout2x3x16_P0.8mm +BGA-96, http://www.mouser.com/ds/2/198/43-46TR16640B-81280BL-706483.pdf +BGA-96 +0 +96 +96 +Package_BGA +BGA-100_6.0x6.0mm_Layout11x11_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-100, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00345-01.pdf +Altera BGA-100 M100 MBGA +0 +100 +100 +Package_BGA +BGA-100_11.0x11.0mm_Layout10x10_P1.0mm_Ball0.5mm_Pad0.4mm_NSMD +BGA-100, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00223-02.pdf +BGA-100 +0 +100 +100 +Package_BGA +BGA-121_9.0x9.0mm_Layout11x11_P0.8mm_Ball0.4mm_Pad0.35mm_NSMD +121-ball, 0.8mm BGA (based on http://www.latticesemi.com/view_document?document_id=213) +BGA 0.8mm 9mm 121 +0 +121 +121 +Package_BGA +BGA-121_12.0x12.0mm_Layout11x11_P1.0mm +BGA-121, http://cds.linear.com/docs/en/packaging/05081891_A_bga121.pdf +BGA-121 +0 +121 +121 +Package_BGA +BGA-132_12x18mm_Layout11x17_P0.5mm +BGA-132 11x17 12x18mm 0.5pitch +BGA-132 +0 +132 +132 +Package_BGA +BGA-144_7.0x7.0mm_Layout13x13_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-144, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00346-00.pdf +Altera BGA-144 M144 MBGA +0 +144 +144 +Package_BGA +BGA-144_13.0x13.0mm_Layout12x12_P1.0mm +BGA-144, http://www.topline.tv/drawings/pdf/BGA%201,0mm%20pitch/LBGA144T1.0-DC128.pdf +BGA-144 +0 +144 +144 +Package_BGA +BGA-152_14x18mm_Layout13x17_P0.5mm +BGA-152_14x18mm_Layout13x17_P0.5mm +VBGA-152 +0 +152 +152 +Package_BGA +BGA-153_8.0x8.0mm_Layout15x15_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-153, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00471-00.pdf +Altera BGA-153 M153 MBGA +0 +153 +153 +Package_BGA +BGA-169_11.0x11.0mm_Layout13x13_P0.8mm_Ball0.5mm_Pad0.4mm_NSMD +Altera U169, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00470-01.pdf +Altera UBGA U169 BGA-169 +0 +169 +169 +Package_BGA +BGA-256_11.0x11.0mm_Layout20x20_P0.5mm_Ball0.3mm_Pad0.25mm_NSMD +Altera MBGA-256, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00348-01.pdf +Altera BGA-256 M256 MBGA +0 +256 +256 +Package_BGA +BGA-256_14.0x14.0mm_Layout16x16_P0.8mm_Ball0.45mm_Pad0.32mm_NSMD +BGA-256, dimensions: https://www.xilinx.com/support/documentation/package_specs/ft256.pdf, design rules: https://www.xilinx.com/support/documentation/user_guides/ug1099-bga-device-design-rules.pdf +BGA-256 +0 +256 +256 +Package_BGA +BGA-256_17.0x17.0mm_Layout16x16_P1.0mm_Ball0.5mm_Pad0.4mm_NSMD +BGA-256, dimensions: https://www.xilinx.com/support/documentation/package_specs/ft256.pdf, design rules: https://www.xilinx.com/support/documentation/user_guides/ug1099-bga-device-design-rules.pdf +BGA-256 +0 +256 +256 +Package_BGA +BGA-324_15.0x15.0mm_Layout18x18_P0.8mm_Ball0.5mm_Pad0.4mm_NSMD +Altera U324, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00474-02.pdf +Altera UBGA U324 BGA-324 +0 +324 +324 +Package_BGA +BGA-324_19.0x19.0mm_Layout18x18_P1.0mm_Ball0.5mm_Pad0.4mm_NSMD +BGA-324, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00233-03.pdf +BGA-324 +0 +324 +324 +Package_BGA +BGA-352_35.0x35.0mm_Layout26x26_P1.27mm +BGA-352, https://www.fujitsu.com/downloads/MICRO/fma/pdfmcu/b352p05.pdf +BGA-352 +0 +352 +352 +Package_BGA +BGA-400_21.0x21.0mm_Layout20x20_P1.0mm +BGA-400, https://www.xilinx.com/support/documentation/package_specs/fg400.pdf +BGA-400 +0 +400 +400 +Package_BGA +BGA-484_23.0x23.0mm_Layout22x22_P1.0mm +BGA-484, https://www.xilinx.com/support/documentation/package_specs/fg484.pdf +BGA-484 +0 +484 +484 +Package_BGA +BGA-624_21.0x21.0mm_Layout25x25_P0.8mm +BGA-624, 25x25 grid, 21x21mm package, pitch 0.8mm; https://www.nxp.com/docs/en/package-information/SOT1529-1.pdf +BGA 624 0.8 +0 +624 +624 +Package_BGA +BGA-625_21.0x21.0mm_Layout25x25_P0.8mm +BGA-625 +BGA-625 +0 +625 +625 +Package_BGA +BGA-672_27.0x27.0mm_Layout26x26_P1.0mm_Ball0.6mm_Pad0.5mm_NSMD +Altera BGA-672, https://www.altera.com/content/dam/altera-www/global/en_US/pdfs/literature/packaging/04r00472-00.pdf +Altera BGA-672 F672 FBGA +0 +672 +672 +Package_BGA +BGA-676_27.0x27.0mm_Layout26x26_P1.0mm_Ball0.6mm_Pad0.5mm_NSMD +XILINX BGA-676, https://www.xilinx.com/support/documentation/package_specs/fg676.pdf +XILINX BGA-676 FG676/FGG676 +0 +676 +676 +Package_BGA +BGA-1023_33.0x33.0mm_Layout32x32_P1.0mm +BGA-1023 +BGA-1023 +0 +1023 +1023 +Package_BGA +BGA-1156_35.0x35.0mm_Layout34x34_P1.0mm +BGA-1156 +BGA-1156 +0 +1156 +1156 +Package_BGA +BGA-1295_37.5x37.5mm_Layout36x36_P1.0mm +BGA-1295 +BGA-1295 +0 +1295 +1295 +Package_BGA +FB-BGA-484_23.0x23.0mm_Layout22x22_P1.0mm +Xilinx FB-484, https://www.xilinx.com/support/documentation/user_guides/ug1099-bga-device-design-rules.pdf +FB-BGA-484 +0 +484 +484 +Package_BGA +FBGA-78_7.5x11mm_Layout2x3x13_P0.8mm +FBGA-78, https://www.skhynix.com/product/filedata/fileDownload.do?seq=7687 +FBGA-78 +0 +78 +78 +Package_BGA +Fujitsu_WLP-15_2.28x3.092mm_Layout3x5_P0.4mm +WLP-15, 3x5 raster, 2.28x3.092mm package, pitch 0.4mm; http://www.fujitsu.com/global/documents/products/devices/semiconductor/fram/lineup/MB85RS1MT-DS501-00022-7v0-E.pdf +BGA 8 0.4 +0 +8 +8 +Package_BGA +LFBGA-100_10x10mm_Layout10x10_P0.8mm +LFBGA-100, 10x10 raster, 10x10mm package, pitch 0.8mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f103tb.pdf +BGA 100 0.8 +0 +100 +100 +Package_BGA +LFBGA-144_10x10mm_Layout12x12_P0.8mm +LFBGA-144, 12x12 raster, 10x10mm package, pitch 0.8mm; see section 6.1 of http://www.st.com/resource/en/datasheet/stm32f103ze.pdf +BGA 144 0.8 +0 +144 +144 +Package_BGA +LFBGA-169_16x12mm_Layout28x14_P0.5mm_Ball0.3_Pad0.3mm_NSMD +https://4donline.ihs.com/images/VipMasterIC/IC/SGST/SGSTS20279/SGSTS20279-1.pdf?hkey=EF798316E3902B6ED9A73243A3159BB0 +eMMC Flash LFBGA169 +0 +169 +169 +Package_BGA +Lattice_caBGA-381_17.0x17.0mm_Layout20x20_P0.8mm_Ball0.4mm_Pad0.4mm_NSMD +Lattice caBGA-381 footprint for ECP5 FPGAs, based on http://www.latticesemi.com/view_document?document_id=213 +BGA 381 0.8 +0 +381 +381 +Package_BGA +Lattice_caBGA-381_17.0x17.0mm_Layout20x20_P0.8mm_Ball0.4mm_Pad0.6mm_SMD +Lattice caBGA-381 footprint for ECP5 FPGAs, based on http://www.latticesemi.com/view_document?document_id=213 +BGA 381 0.8 +0 +381 +381 +Package_BGA +Linear_BGA-133_15.0x15.0mm_Layout12x12_P1.27mm +Analog Devices (Linear Tech), 133-pin BGA uModule, 15.0x15.0x4.92mm, https://www.analog.com/media/en/technical-documentation/data-sheets/4637fc.pdf +133 pin bga +0 +134 +134 +Package_BGA +Maxim_WLP-9_1.595x1.415_Layout3x3_P0.4mm_Ball0.27mm_Pad0.25mm_NSMD +Maxim_WLP-9 W91C1+1 https://pdfserv.maximintegrated.com/package_dwgs/21-0459.PDF +Maxim_WLP-9 +0 +9 +9 +Package_BGA +Maxim_WLP-12 +Maxim_WLP-12 W121B2+1 http://pdfserv.maximintegrated.com/package_dwgs/21-0009.PDF +Maxim_WLP-12 +0 +12 +12 +Package_BGA +Microchip_TFBGA-196_11x11mm_Layout14x14_P0.75mm_SMD +TFBGA-196, 11.0x11.0mm, 196 Ball, 14x14 Layout, 0.75mm Pitch, http://ww1.microchip.com/downloads/en/DeviceDoc/SAMA5D2-Series-Data-Sheet-DS60001476C.pdf#page=2956 +BGA 196 0.75 +0 +196 +196 +Package_BGA +ST_uTFBGA-36_3.6x3.6mm_Layout6x6_P0.5mm +ST uTFBGA-36, 0.25mm pad, 3.6x3.6mm, 36 Ball, 6x6 Layout, 0.5mm Pitch, https://www.st.com/resource/en/datasheet/stulpi01a.pdf +BGA 36 0.5 +0 +36 +36 +Package_BGA +TFBGA-64_5x5mm_Layout8x8_P0.5mm +TFBGA-64, 8x8 raster, 5x5mm package, pitch 0.5mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f100v8.pdf +BGA 64 0.5 +0 +64 +64 +Package_BGA +TFBGA-100_8x8mm_Layout10x10_P0.8mm +TFBGA-100, 10x10 raster, 8x8mm package, pitch 0.8mm; see section 6.2 of http://www.st.com/resource/en/datasheet/stm32f746zg.pdf +BGA 100 0.8 +0 +100 +100 +Package_BGA +TFBGA-100_9.0x9.0mm_Layout10x10_P0.8mm +TFBGA-100, 10x10, 9x9mm package, pitch 0.8mm +TFBGA-100 +0 +100 +100 +Package_BGA +TFBGA-121_10x10mm_Layout11x11_P0.8mm +TFBGA-121, 11x11 raster, 10x10mm package, pitch 0.8mm; http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#p495 +BGA 121 0.8 +0 +121 +121 +Package_BGA +TFBGA-216_13x13mm_Layout15x15_P0.8mm +TFBGA-216, 15x15 raster, 13x13mm package, pitch 0.8mm; see section 6.8 of http://www.st.com/resource/en/datasheet/stm32f746zg.pdf +BGA 216 0.8 +0 +216 +216 +Package_BGA +TFBGA-265_14x14mm_Layout17x17_P0.8mm +TFBGA-265, 17x17 raster, 14x14mm package, pitch 0.8mm; see section 7.8 of http://www.st.com/resource/en/datasheet/DM00387108.pdf +BGA 265 0.8 +0 +265 +265 +Package_BGA +Texas_DSBGA-5_0.822x1.116mm_Layout2x1x2_P0.4mm +Texas Instruments, DSBGA, 0.822x1.116mm, 5 bump 2x1x2 array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/opa330.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YFF S-XBGA-N5 +0 +10 +5 +Package_BGA +Texas_DSBGA-6_0.9x1.4mm_Layout2x3_P0.5mm +Texas Instruments, DSBGA, 0.9x1.4mm, 6 bump 2x3 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/ts5a3159a.pdf) +Texas Instruments DSBGA BGA YZP R-XBGA-N6 +0 +12 +6 +Package_BGA +Texas_DSBGA-8_0.9x1.9mm_Layout2x4_P0.5mm +Texas Instruments, DSBGA, 0.9x1.9mm, 8 bump 2x4 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txb0102.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YZP R-XBGA-N8 +0 +16 +8 +Package_BGA +Texas_DSBGA-8_1.43x1.41mm_Layout3x3_P0.5mm +Texas Instruments, DSBGA, 1.43x1.41mm, 8 bump 3x3 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/lmc555.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YZP R-XBGA-N8 +0 +16 +8 +Package_BGA +Texas_DSBGA-8_1.5195x1.5195mm_Layout3x3_P0.5mm +Texas Instruments, DSBGA, 1.5195x1.5195x0.600mm, 8 ball 3x3 area grid, YZR pad definition (http://www.ti.com/lit/ml/mxbg270/mxbg270.pdf) +BGA 8 0.5 +0 +8 +8 +Package_BGA +Texas_DSBGA-9_1.4715x1.4715mm_Layout3x3_P0.5mm +Texas Instruments, DSBGA, 1.4715x1.4715mm, 9 bump 3x3 array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/lm4990.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA YZR0009 +0 +18 +9 +Package_BGA +Texas_DSBGA-10_1.36x1.86mm_Layout3x4_P0.5mm +Texas Instruments, DSBGA, 1.36x1.86mm, 10 bump 3x4 (perimeter) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txs0104e.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA +0 +20 +10 +Package_BGA +Texas_DSBGA-12_1.36x1.86mm_Layout3x4_P0.5mm +Texas Instruments, DSBGA, 1.36x1.86mm, 12 bump 3x4 (area) array, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txs0104e.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +Texas Instruments DSBGA BGA +0 +24 +12 +Package_BGA +Texas_DSBGA-28_1.9x3.0mm_Layout4x7_P0.4mm +Texas Instruments, DSBGA, 3.0x1.9x0.625mm, 28 ball 7x4 area grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/bq51050b.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +BGA 28 0.4 +0 +28 +28 +Package_BGA +Texas_DSBGA-49_3.33x3.488mm_Layout7x7_P0.4mm +Texas Instruments, DSBGA, 3.33x3.488x0.625mm, 49 ball 7x7 area grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/msp430f2234.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +texas dsbga 49 +0 +49 +49 +Package_BGA +Texas_DSBGA-64_3.415x3.535mm_Layout8x8_P0.4mm +Texas Instruments, DSBGA, 3.415x3.535x0.625mm, 64 ball 8x8 area grid, NSMD pad definition (http://www.ti.com/lit/ds/slas718g/slas718g.pdf, http://www.ti.com/lit/an/snva009ag/snva009ag.pdf) +texas dsbga 64 +0 +64 +64 +Package_BGA +Texas_MicroStar_Junior_BGA-12_2.0x2.5mm_Layout4x3_P0.5mm +Texas Instruments, BGA Microstar Junior, 2x2.5mm, 12 bump 4x3 grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/txb0104.pdf, http://www.ti.com/lit/wp/ssyz015b/ssyz015b.pdf) +Texas_Junior_BGA-12 +0 +12 +12 +Package_BGA +Texas_MicroStar_Junior_BGA-80_5.0x5.0mm_Layout9x9_P0.5mm +Texas Instruments, BGA Microstar Junior, 5x5mm, 80 ball 9x9 grid, NSMD pad definition (http://www.ti.com/lit/ds/symlink/tlv320aic23b.pdf, http://www.ti.com/lit/wp/ssyz015b/ssyz015b.pdf) +Texas_Junior_BGA-80 +0 +80 +80 +Package_BGA +Texas_MicroStar_Junior_BGA-113_7.0x7.0mm_Layout12x12_P0.5mm +Texas Instruments, BGA Microstar Junior, 7x7mm, 113 ball 12x12 grid, NSMD pad definition (http://www.ti.com/lit/ml/mpbg674/mpbg674.pdf, http://www.ti.com/lit/wp/ssyz015b/ssyz015b.pdf) +Texas_Junior_BGA-113 +0 +113 +113 +Package_BGA +UCBGA-36_2.5x2.5mm_Layout6x6_P0.4mm +UCBGA-36, 6x6 raster, 2.5x2.5mm package, pitch 0.4mm; https://www.latticesemi.com/view_document?document_id=213 +BGA 36 0.4 +0 +36 +36 +Package_BGA +UCBGA-49_3x3mm_Layout7x7_P0.4mm +UCBGA-49, 7x7 raster, 3x3mm package, pitch 0.4mm; https://www.latticesemi.com/view_document?document_id=213 +BGA 49 0.4 +0 +49 +49 +Package_BGA +UCBGA-81_4x4mm_Layout9x9_P0.4mm +UCBGA-81, 9x9 raster, 4x4mm package, pitch 0.4mm; https://www.latticesemi.com/view_document?document_id=213 +BGA 81 0.4 +0 +81 +81 +Package_BGA +UFBGA-15_3.0x3.0mm_Layout4x4_P0.65mm +UFBGA-15, 4x4, 3x3mm package, pitch 0.65mm +UFBGA-15 +0 +15 +15 +Package_BGA +UFBGA-32_4.0x4.0mm_Layout6x6_P0.5mm +UFBGA-32, 6x6, 4x4mm package, pitch 0.5mm +UFBGA-32 +0 +32 +32 +Package_BGA +UFBGA-64_5x5mm_Layout8x8_P0.5mm +UFBGA-64, 8x8 raster, 5x5mm package, pitch 0.5mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f051t8.pdf +BGA 64 0.5 +0 +64 +64 +Package_BGA +UFBGA-100_7x7mm_Layout12x12_P0.5mm +UFBGA-100, 12x12 raster, 7x7mm package, pitch 0.5mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f103tb.pdf +BGA 100 0.5 +0 +100 +100 +Package_BGA +UFBGA-132_7x7mm_Layout12x12_P0.5mm +UFBGA-132, 12x12 raster, 7x7mm package, pitch 0.5mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32l152zc.pdf +BGA 132 0.5 +0 +132 +132 +Package_BGA +UFBGA-132_7x7mm_P0.5mm +UFBGA 132 Pins, 0.5mm Pitch, 0.3mm Ball, http://www.st.com/resource/en/datasheet/stm32l486qg.pdf +ufbga bga small-pitch +0 +132 +132 +Package_BGA +UFBGA-144_7x7mm_Layout12x12_P0.5mm +UFBGA-144, 12x12 raster, 7x7mm package, pitch 0.5mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f446ze.pdf +BGA 144 0.5 +0 +144 +144 +Package_BGA +UFBGA-144_10x10mm_Layout12x12_P0.8mm +UFBGA-144, 12x12 raster, 10x10mm package, pitch 0.8mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f446ze.pdf +BGA 144 0.8 +0 +144 +144 +Package_BGA +UFBGA-169_7x7mm_Layout13x13_P0.5mm +UFBGA-169, 13x13 raster, 7x7mm package, pitch 0.5mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32f429ng.pdf +BGA 169 0.5 +0 +169 +169 +Package_BGA +UFBGA-201_10x10mm_Layout15x15_P0.65mm +UFBGA-201, 15x15 raster, 10x10mm package, pitch 0.65mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32f207vg.pdf +BGA 201 0.65 +0 +201 +201 +Package_BGA +VFBGA-49_5.0x5.0mm_Layout7x7_P0.65mm +VFBGA-49, 7x7, 5x5mm package, pitch 0.65mm +VFBGA-49 +0 +49 +49 +Package_BGA +VFBGA-100_7.0x7.0mm_Layout10x10_P0.65mm +VFBGA-100, 10x10, 7x7mm package, pitch 0.65mm +VFBGA-100 +0 +100 +100 +Package_BGA +WLP-4_0.73x0.73mm_Layout2x2_P0.35mm_Ball0.22mm_Pad0.2mm_NSMD +WLP-4, 2x2 raster, 0.73x0.73mm package, pitch 0.35mm; https://datasheets.maximintegrated.com/en/ds/MAX40200.pdf +BGA 4 0.35 +0 +4 +4 +Package_BGA +WLP-4_0.83x0.83mm_P0.4mm +WLP-4_0.83x0.83mm_P0.4mm https://pdfserv.maximintegrated.com/package_dwgs/21-100107.PDF, https://www.maximintegrated.com/en/app-notes/index.mvp/id/1891 +WLP-4 +0 +4 +4 +Package_BGA +WLP-4_0.86x0.86mm_P0.4mm +WLP-4_0.86x0.86mm_P0.4mm https://pdfserv.maximintegrated.com/package_dwgs/21-0612.PDF, https://www.maximintegrated.com/en/app-notes/index.mvp/id/1891 +WLP-4 +0 +4 +4 +Package_BGA +WLP-9_1.448x1.468mm_Layout3x3_P0.4mm_Ball0.27mm_Pad0.25mm +WLP-9, 1.448x1.468mm, 9 Ball, 3x3 Layout, 0.4mm Pitch, https://pdfserv.maximintegrated.com/package_dwgs/21-100168.PDF +BGA 9 0.4 +0 +9 +9 +Package_BGA +XBGA-121_10x10mm_Layout11x11_P0.8mm +XBGA-121, 11x11 raster, 10x10mm package, pitch 0.6mm; http://ww1.microchip.com/downloads/en/DeviceDoc/39969b.pdf +BGA 121 0.8 +0 +121 +121 +Package_BGA +XFBGA-36_3.5x3.5mm_Layout6x6_P0.5mm +XFBGA-36, https://www.nxp.com/docs/en/package-information/SOT1555-1.pdf +XFBGA-36 +0 +36 +36 +Package_BGA +XFBGA-64_5.0x5.0mm_Layout8x8_P0.5mm +XFBGA-64, https://www.nxp.com/docs/en/package-information/SOT1555-1.pdf +XFBGA-64 +0 +64 +64 +Package_BGA +XFBGA-121_8x8mm_Layout11x11_P0.65mm +XFBGA-121, https://www.nxp.com/docs/en/package-information/SOT1533-1.pdf +XFBGA-121 +0 +121 +121 +Package_BGA +Xilinx_CLG225 +Zynq-7000 BGA, 15x15 grid, 13x13mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=77, NSMD pad definition Appendix A +BGA 225 0.8 CLG225 +0 +225 +225 +Package_BGA +Xilinx_CLG400 +Zynq-7000 BGA, 20x20 grid, 17x17mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=78, NSMD pad definition Appendix A +BGA 400 0.8 CLG400 CL400 +0 +400 +400 +Package_BGA +Xilinx_CLG484_CLG485 +Zynq-7000 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=79, NSMD pad definition Appendix A +BGA 484 0.8 CLG484 CL484 CLG485 CL485 +0 +484 +484 +Package_BGA +Xilinx_CPG236 +Artix-7 BGA, 19x19 grid, 10x10mm package, 0.5mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=266, NSMD pad definition Appendix A +BGA 238 0.5 CP236 CPG236 +0 +238 +238 +Package_BGA +Xilinx_CPG238 +Artix-7 BGA, 19x19 grid, 10x10mm package, 0.5mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=267, NSMD pad definition Appendix A +BGA 238 0.5 CPG238 +0 +238 +238 +Package_BGA +Xilinx_CPGA196 +Spartan-7 BGA, 14x14 grid, 8x8mm package, 0.5mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=260, NSMD pad definition Appendix A +BGA 196 0.5 CPGA196 +0 +196 +196 +Package_BGA +Xilinx_CSG324 +Artix-7 BGA, 18x18 grid, 15x15mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=268, NSMD pad definition Appendix A +BGA 324 0.8 CS324 CSG324 +0 +324 +324 +Package_BGA +Xilinx_CSG325 +Artix-7 BGA, 18x18 grid, 15x15mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=268, NSMD pad definition Appendix A +BGA 324 0.8 CS325 CSG235 +0 +324 +324 +Package_BGA +Xilinx_CSGA225 +Spartan-7 BGA, 15x15 grid, 13x13mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=262, NSMD pad definition Appendix A +BGA 225 0.8 CSGA225 +0 +225 +225 +Package_BGA +Xilinx_CSGA324 +Spartan-7 BGA, 18x18 grid, 15x15mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=263, NSMD pad definition Appendix A +BGA 324 0.8 CSGA324 +0 +324 +324 +Package_BGA +Xilinx_FBG484 +Artix-7, Kintex-7 and Zynq-7000 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=271, ttps://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=281, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=82, NSMD pad definition Appendix A +BGA 484 1 FB484 FBG484 FBV484 +0 +484 +484 +Package_BGA +Xilinx_FBG676 +Artix-7, Kintex-7 and Zynq-7000 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=273, https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=284, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=84, NSMD pad definition Appendix A +BGA 676 1 FB676 FBG676 FBV676 +0 +676 +676 +Package_BGA +Xilinx_FBG900 +Kintex-7 BGA, 30x30 grid, 31x31mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=289, NSMD pad definition Appendix A +BGA 900 1 FB900 FBG900 FBV900 +0 +900 +900 +Package_BGA +Xilinx_FFG676 +Kintex-7 and Zynq-7000 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=292, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=88, NSMD pad definition Appendix A +BGA 676 1 FF676 FFG676 FFV676 +0 +676 +676 +Package_BGA +Xilinx_FFG900_FFG901 +Kintex-7 and Zynq-7000 BGA, 30x30 grid, 31x31mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=294, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=90, NSMD pad definition Appendix A +BGA 900 1 FF900 FFG900 FFV900 FF901 FFG901 FFV901 +0 +900 +900 +Package_BGA +Xilinx_FFG1156 +Artix-7, Kintex-7 and Zynq-7000 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=277, https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=296, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=91, NSMD pad definition Appendix A +BGA 1156 1 FF1156 FFG1156 FFV1156 +0 +1156 +1156 +Package_BGA +Xilinx_FFG1157_FFG1158 +Virtex-7 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=299, NSMD pad definition Appendix A +BGA 1156 1 FF1157 FFG1157 FFV1157 FF1158 FFG1158 FFV1158 +0 +1156 +1156 +Package_BGA +Xilinx_FFG1761 +Virtex-7 BGA, 42x42 grid, 42.5x42.5mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=300, NSMD pad definition Appendix A +BGA 1760 1 FF1761 FFG1761 +0 +1760 +1760 +Package_BGA +Xilinx_FFG1926_FFG1927_FFG1928_FFG1930 +Virtex-7 BGA, 44x44 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=303, NSMD pad definition Appendix A +BGA 1924 1 FF1926 FFG1926 FF1927 FFG1927 FFV1927 FF1928 FFG1928 FF1930 FFG1930 +0 +1924 +1924 +Package_BGA +Xilinx_FFV1761 +Virtex-7 BGA, 42x42 grid, 42.5x42.5mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=301, NSMD pad definition Appendix A +BGA 1760 1 FFV1761 +0 +1760 +1760 +Package_BGA +Xilinx_FGG484 +Artix-7 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=275, NSMD pad definition Appendix A +BGA 484 1 FG484 FGG484 +0 +484 +484 +Package_BGA +Xilinx_FGG676 +Artix-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=276, NSMD pad definition Appendix A +BGA 676 1 FG676 FGG676 +0 +676 +676 +Package_BGA +Xilinx_FGGA484 +Spartan-7 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=264, NSMD pad definition Appendix A +BGA 484 1 FGGA484 +0 +484 +484 +Package_BGA +Xilinx_FGGA676 +Spartan-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=265, NSMD pad definition Appendix A +BGA 676 1 FGGA676 +0 +676 +676 +Package_BGA +Xilinx_FHG1761 +Virtex-7 BGA, 42x42 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=302, NSMD pad definition Appendix A +BGA 1760 1 FH1761 FHG1761 +0 +1760 +1760 +Package_BGA +Xilinx_FLG1925_FLG1926_FLG1928_FLG1930 +Virtex-7 BGA, 44x44 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=304, NSMD pad definition Appendix A +BGA 1924 1 FL1925 FLG1925 FL1926 FLG1926 FL1928 FLG1928 FL1930 FLG1930 +0 +1924 +1924 +Package_BGA +Xilinx_FTG256 +Artix-7 BGA, 16x16 grid, 17x17mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=269, NSMD pad definition Appendix A +BGA 256 1 FT256 FTG256 +0 +256 +256 +Package_BGA +Xilinx_FTGB196 +Spartan-7 BGA, 14x14 grid, 15x15mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=261, NSMD pad definition Appendix A +BGA 196 1 FTGB196 +0 +196 +196 +Package_BGA +Xilinx_RB484 +Artix-7 and Zynq-7000 BGA, 22x22 grid, 23x23mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=278, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=92, NSMD pad definition Appendix A +BGA 484 1 RB484 +0 +484 +484 +Package_BGA +Xilinx_RB676 +Artix-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=280, NSMD pad definition Appendix A +BGA 676 1 RB676 +0 +676 +676 +Package_BGA +Xilinx_RF676 +Kintex-7 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=297, NSMD pad definition Appendix A +BGA 676 1 RF676 +0 +676 +676 +Package_BGA +Xilinx_RF900 +Kintex-7 and Zynq-7000 BGA, 30x30 grid, 31x31mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=298, https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=94, NSMD pad definition Appendix A +BGA 900 1 RF900 +0 +900 +900 +Package_BGA +Xilinx_RF1156 +Zynq-7000 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=95, NSMD pad definition Appendix A +BGA 1156 1 RF1156 +0 +1156 +1156 +Package_BGA +Xilinx_RF1157_RF1158 +Virtex-7 BGA, 34x34 grid, 35x35mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=305, NSMD pad definition Appendix A +BGA 1156 1 RF1157 RF1158 +0 +1156 +1156 +Package_BGA +Xilinx_RF1761 +Virtex-7 BGA, 42x42 grid, 42.5x42.5mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=306, NSMD pad definition Appendix A +BGA 1760 1 RF1761 +0 +1760 +1760 +Package_BGA +Xilinx_RF1930 +Virtex-7 BGA, 44x44 grid, 45x45mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=307, NSMD pad definition Appendix A +BGA 1924 1 RF1930 +0 +1924 +1924 +Package_BGA +Xilinx_RFG676 +Zynq-7000 BGA, 26x26 grid, 27x27mm package, 1mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=93, NSMD pad definition Appendix A +BGA 676 1 RF676 RFG676 +0 +676 +676 +Package_BGA +Xilinx_RS484 +Artix-7 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=279, NSMD pad definition Appendix A +BGA 484 0.8 RS484 +0 +484 +484 +Package_BGA +Xilinx_SBG484 +Artix-7 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug475_7Series_Pkg_Pinout.pdf#page=270, NSMD pad definition Appendix A +BGA 484 0.8 SB484 SBG484 SBV484 +0 +484 +484 +Package_BGA +Xilinx_SBG485 +Zynq-7000 BGA, 22x22 grid, 19x19mm package, 0.8mm pitch; https://www.xilinx.com/support/documentation/user_guides/ug865-Zynq-7000-Pkg-Pinout.pdf#page=80, NSMD pad definition Appendix A +BGA 484 0.8 SBG485 SBV485 +0 +484 +484 +Package_CSP +Analog_LFCSP-8-1EP_3x3mm_P0.5mm_EP1.53x1.85mm +LFCSP, exposed pad, Analog Devices (http://www.analog.com/media/en/technical-documentation/data-sheets/ADL5542.pdf) +LFCSP 8 0.5 +0 +12 +5 +Package_CSP +LFCSP-8-1EP_3x2mm_P0.5mm_EP1.6x1.65mm +LFCSP 8pin Pitch 0.5mm, http://www.analog.com/media/en/package-pcb-resources/package/57080735642908cp_8_4.pdf +LFCSP 8pin thermal pad 3x2mm Pitch 0.5mm +0 +9 +9 +Package_CSP +LFCSP-8-1EP_3x3mm_P0.5mm_EP1.45x1.74mm +LFCSP, 8 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-8/CP_8_13.pdf), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +LFCSP DFN_QFN +0 +13 +9 +Package_CSP +LFCSP-8_2x2mm_P0.5mm +LFCSP 8pin Pitch 0.5mm, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_8_6.pdf +LFCSP 8pin 2x2mm Pitch 0.5mm +0 +8 +8 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.3x1.3mm +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_21.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.3x1.3mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_21.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +26 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_22.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/CP_16_22.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +26 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm +LFCSP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/HMC7992.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/HMC7992.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +26 +17 +Package_CSP +LFCSP-16-1EP_3x3mm_P0.5mm_EP1.854x1.854mm +16-Lead Lead Frame Chip Scale Package, 3x3mm, 0.5mm pitch, 1.854mm thermal pad (CP-16-22, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_16_22.pdf) +LFCSP 16 0.5 +0 +21 +17 +Package_CSP +LFCSP-16-1EP_4x4mm_P0.65mm_EP2.1x2.1mm +LFCSP, 16 pin, 4x4mm, 2.1mm sq pad (http://www.analog.com/media/en/technical-documentation/data-sheets/ADG633.pdf) +LFCSP 16 0.65 +0 +21 +17 +Package_CSP +LFCSP-16-1EP_4x4mm_P0.65mm_EP2.4x2.4mm +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/cp-16-40.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +21 +17 +Package_CSP +LFCSP-16-1EP_4x4mm_P0.65mm_EP2.4x2.4mm_ThermalVias +LFCSP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-16/cp-16-40.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +31 +17 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.1x2.1mm +20-Lead Frame Chip Scale Package - 4x4x0.9 mm Body [LFCSP], (see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_20_6.pdf) +LFCSP 0.5 +0 +25 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +LFCSP, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/AD7682_7689.pdf), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +LFCSP DFN_QFN +0 +25 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +LFCSP, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/AD7682_7689.pdf), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +LFCSP DFN_QFN +0 +35 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +LFCSP, 20 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-20/CP_20_8.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +25 +21 +Package_CSP +LFCSP-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +LFCSP, 20 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-20/CP_20_8.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +35 +21 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.3x2.3mm +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_14.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +29 +25 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.3x2.3mm_ThermalVias +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_14.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +39 +25 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +29 +25 +Package_CSP +LFCSP-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +LFCSP, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_24_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +39 +25 +Package_CSP +LFCSP-28-1EP_5x5mm_P0.5mm_EP3.14x3.14mm +LFCSP, 28 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-28/CP_28_10.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +33 +29 +Package_CSP +LFCSP-28-1EP_5x5mm_P0.5mm_EP3.14x3.14mm_ThermalVias +LFCSP, 28 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-28/CP_28_10.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +43 +29 +Package_CSP +LFCSP-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +LFCSP, 32 Pin (https://www.analog.com/media/en/package-pcb-resources/package/414143737956480539664569cp_32_2.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +42 +33 +Package_CSP +LFCSP-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +LFCSP, 32 Pin (https://www.analog.com/media/en/package-pcb-resources/package/414143737956480539664569cp_32_2.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +59 +33 +Package_CSP +LFCSP-32-1EP_5x5mm_P0.5mm_EP3.25x3.25mm +32-Lead Frame Chip Scale Package LFCSP (5mm x 5mm); (see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-32/CP_32_27.pdf +LFCSP 0.5 +0 +37 +33 +Package_CSP +LFCSP-48-1EP_7x7mm_P0.5mm_EP4.1x4.1mm +LFCSP, 48 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_48_5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +58 +49 +Package_CSP +LFCSP-48-1EP_7x7mm_P0.5mm_EP4.1x4.1mm_ThermalVias +LFCSP, 48 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_48_5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +75 +49 +Package_CSP +LFCSP-64-1EP_9x9mm_P0.5mm_EP5.21x5.21mm +LFCSP, 64 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_64_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +69 +65 +Package_CSP +LFCSP-64-1EP_9x9mm_P0.5mm_EP5.21x5.21mm_ThermalVias +LFCSP, 64 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp_64_7.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +86 +65 +Package_CSP +LFCSP-72-1EP_10x10mm_P0.5mm_EP5.3x5.3mm +LFCSP, 72 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/ADAU1452_1451_1450.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +82 +73 +Package_CSP +LFCSP-72-1EP_10x10mm_P0.5mm_EP5.3x5.3mm_ThermalVias +LFCSP, 72 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/ADAU1452_1451_1450.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP NoLead +0 +99 +73 +Package_CSP +LFCSP-72-1EP_10x10mm_P0.5mm_EP6.15x6.15mm +72-Lead Frame Chip Scale Package - 10x10x0.9 mm Body [LFCSP]; (see https://www.intersil.com/content/dam/Intersil/documents/l72_/l72.10x10c.pdf) +LFCSP 0.5 +0 +77 +73 +Package_CSP +LFCSP-VQ-24-1EP_4x4mm_P0.5mm_EP2.642x2.642mm +LFCSP VQ, 24 pin, exposed pad, 4x4mm body, pitch 0.5mm (http://www.analog.com/media/en/package-pcb-resources/package/56702234806764cp_24_3.pdf, http://www.analog.com/media/en/technical-documentation/data-sheets/ADL5801.pdf) +LFCSP 0.5 +0 +29 +25 +Package_CSP +LFCSP-VQ-48-1EP_7x7mm_P0.5mm +LFCSP VQ, 48 pin, exposed pad, 7x7mm body (http://www.analog.com/media/en/technical-documentation/data-sheets/AD7951.pdf, http://www.analog.com/en/design-center/packaging-quality-symbols-footprints/symbols-and-footprints/AD7951.html) +LFCSP 48 +0 +49 +49 +Package_CSP +LFCSP-WD-8-1EP_3x3mm_P0.65mm_EP1.6x2.44mm +LFCSP-WD, 8 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/CP_8_19.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +15 +9 +Package_CSP +LFCSP-WD-8-1EP_3x3mm_P0.65mm_EP1.6x2.44mm_ThermalVias +LFCSP-WD, 8 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/CP_8_19.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +22 +9 +Package_CSP +LFCSP-WD-10-1EP_3x3mm_P0.5mm_EP1.64x2.38mm +LFCSP-WD, 10 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-10/CP_10_9.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +17 +11 +Package_CSP +LFCSP-WD-10-1EP_3x3mm_P0.5mm_EP1.64x2.38mm_ThermalVias +LFCSP-WD, 10 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/lfcspcp/cp-10/CP_10_9.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LFCSP-WD NoLead +0 +24 +11 +Package_CSP +ST_WLCSP-25_Die425 +WLCSP-25, 5x5 raster, 2.097x2.493mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32l031f6.pdf +BGA 25 0.4 +0 +25 +25 +Package_CSP +ST_WLCSP-25_Die444 +WLCSP-25, 5x5 raster, 2.423x2.325mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f031k6.pdf +BGA 25 0.4 +0 +25 +25 +Package_CSP +ST_WLCSP-25_Die457 +WLCSP-25, 5x5 raster, 2.133x2.070mm package, pitch 0.4mm; see section 7.3 of http://www.st.com/resource/en/datasheet/stm32l011k3.pdf +BGA 25 0.4 +0 +25 +25 +Package_CSP +ST_WLCSP-36_Die417 +WLCSP-36, 6x6 raster, 2.61x2.88mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32l052t8.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-36_Die440 +WLCSP-36, 6x6 raster, 2.605x2.703mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f051t8.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-36_Die445 +WLCSP-36, 6x6 raster, 2.605x2.703mm package, pitch 0.4mm; see section 7.3 of http://www.st.com/resource/en/datasheet/stm32f042k6.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-36_Die458 +WLCSP-36, 6x6 raster, 2.553x2.579mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f410t8.pdf +BGA 36 0.4 +0 +36 +36 +Package_CSP +ST_WLCSP-49_Die423 +WLCSP-49, 7x7 raster, 2.965x2.965mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f401vc.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die431 +WLCSP-49, 7x7 raster, 2.999x3.185mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f411vc.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die433 +WLCSP-49, 7x7 raster, 3.029x3.029mm package, pitch 0.4mm; see section 7.1.1 of http://www.st.com/resource/en/datasheet/stm32f401ce.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die435 +WLCSP-49, 7x7 raster, 3.141x3.127mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/DM00257211.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die438 +WLCSP-49, 7x7 raster, 3.89x3.74mm package, pitch 0.5mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f303r8.pdf +BGA 49 0.5 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die439 +WLCSP-49, 7x7 raster, 3.417x3.151mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/stm32f301r8.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die447 +WLCSP-49, 7x7 raster, 3.294x3.258mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32l072kz.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-49_Die448 +WLCSP-49, 7x7 raster, 3.277x3.109mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f071v8.pdf +BGA 49 0.4 +0 +49 +49 +Package_CSP +ST_WLCSP-63_Die427 +WLCSP-63, 7x9 raster, 3.228x4.164mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32l151cc.pdf +BGA 63 0.4 +0 +63 +63 +Package_CSP +ST_WLCSP-64_Die414 +WLCSP-64, 8x8 raster, 4.466x4.395mm package, pitch 0.5mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f103ze.pdf +BGA 64 0.5 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die427 +WLCSP-64, 8x8 raster, 4.539x4.911mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l152zc.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die435 +WLCSP-64, 8x8 raster, 3.141x3.127mm package, pitch 0.35mm; see section 7.5 of http://www.st.com/resource/en/datasheet/DM00257211.pdf +BGA 64 0.35 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die436 +WLCSP-64, 8x8 raster, 4.539x4.911mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l152zd.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die441 +WLCSP-64, 8x8 raster, 3.623x3.651mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/DM00213872.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die442 +WLCSP-64, 8x8 raster, 3.347x3.585mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f091vb.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-64_Die462 +WLCSP-64, 8x8 raster, 3.357x3.657mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/DM00340475.pdf +BGA 64 0.4 +0 +64 +64 +Package_CSP +ST_WLCSP-66_Die411 +WLCSP-66, 9x9 raster, 3.639x3.971mm package, pitch 0.4mm; see section 7.2 of http://www.st.com/resource/en/datasheet/stm32f207vg.pdf +BGA 66 0.4 +0 +66 +66 +Package_CSP +ST_WLCSP-66_Die432 +WLCSP-66, 8x9 raster, 3.767x4.229mm package, pitch 0.4mm; see section 7.2 of http://www.st.com/resource/en/datasheet/stm32f378vc.pdf +BGA 66 0.4 +0 +66 +66 +Package_CSP +ST_WLCSP-72_Die415 +WLCSP-72, 9x9 raster, 4.4084x3.7594mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l476me.pdf +BGA 72 0.4 +0 +72 +72 +Package_CSP +ST_WLCSP-81_Die415 +WLCSP-81, 9x9 raster, 4.4084x3.7594mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32l476me.pdf +BGA 81 0.4 +0 +81 +81 +Package_CSP +ST_WLCSP-81_Die421 +WLCSP-81, 9x9 raster, 3.693x3.815mm package, pitch 0.4mm; see section 7.6 of http://www.st.com/resource/en/datasheet/stm32f446ze.pdf +BGA 81 0.4 +0 +81 +81 +Package_CSP +ST_WLCSP-81_Die463 +WLCSP-81, 9x9 raster, 4.039x3.951mm package, pitch 0.4mm; see section 7.1 of http://www.st.com/resource/en/datasheet/DM00282249.pdf +BGA 81 0.4 +0 +81 +81 +Package_CSP +ST_WLCSP-90_Die413 +WLCSP-90, 10x9 raster, 4.223x3.969mm package, pitch 0.4mm; see section 6.1 of http://www.st.com/resource/en/datasheet/stm32f405og.pdf +BGA 90 0.4 +0 +90 +90 +Package_CSP +ST_WLCSP-100_Die422 +WLCSP-100, 10x10 raster, 4.201x4.663mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/stm32f302vc.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-100_Die446 +WLCSP-100, 10x10 raster, 4.775x5.041mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32f303zd.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-100_Die452 +WLCSP-100, 10x10 raster, 4.201x4.663mm package, pitch 0.4mm; see section 7.7 of http://www.st.com/resource/en/datasheet/DM00330506.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-100_Die461 +WLCSP-100, 10x10 raster, 4.618x4.142mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/DM00284211.pdf +BGA 100 0.4 +0 +100 +100 +Package_CSP +ST_WLCSP-104_Die437 +WLCSP-104, 9x12 raster, 4.095x5.094mm package, pitch 0.4mm; see section 7.5 of http://www.st.com/resource/en/datasheet/stm32l152ze.pdf +BGA 104 0.4 +0 +104 +104 +Package_CSP +ST_WLCSP-143_Die419 +WLCSP-143, 11x13 raster, 4.521x5.547mm package, pitch 0.4mm; see section 7.2 of http://www.st.com/resource/en/datasheet/stm32f429ng.pdf +BGA 143 0.4 +0 +143 +143 +Package_CSP +ST_WLCSP-143_Die449 +WLCSP-143, 11x13 raster, 4.539x5.849mm package, pitch 0.4mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f746zg.pdf +BGA 143 0.4 +0 +143 +143 +Package_CSP +ST_WLCSP-144_Die470 +WLCSP-144, 12x12 raster, 5.24x5.24mm package, pitch 0.4mm; see section 7.4 of http://www.st.com/resource/en/datasheet/DM00366448.pdf +BGA 144 0.4 +0 +144 +144 +Package_CSP +ST_WLCSP-168_Die434 +WLCSP-168, 12x14 raster, 4.891x5.692mm package, pitch 0.4mm; see section 6.3 of http://www.st.com/resource/en/datasheet/stm32f469ni.pdf +BGA 168 0.4 +0 +168 +168 +Package_CSP +ST_WLCSP-180_Die451 +WLCSP-180, 13x14 raster, 5.537x6.095mm package, pitch 0.4mm; see section 6.6 of http://www.st.com/resource/en/datasheet/DM00273119.pdf +BGA 180 0.4 +0 +180 +180 +Package_CSP +WLCSP-6_1.4x1.0mm_P0.4mm +6pin Pitch 0.4mm +6pin Pitch 0.4mm WLCSP +0 +6 +6 +Package_CSP +WLCSP-8_1.58x1.63x0.35mm_Layout3x5_P0.35x0.4mm_Ball0.25mm_Pad0.25mm_NSMD +WLCSP/XFBGA 8-pin package, staggered pins, http://www.adestotech.com/wp-content/uploads/DS-AT25DF041B_040.pdf +WLCSP WLCSP-8 XFBGA XFBGA-8 CSP BGA Chip-Scale Glass-Top +0 +8 +8 +Package_CSP +WLCSP-12_1.56x1.56mm_P0.4mm +WLCSP 12 1.56x1.56 https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMM150-DS001-01.pdf +BMM150 WLCSP +0 +12 +12 +Package_CSP +WLCSP-12_1.403x1.555mm_P0.4mm_Stagger +WLCSP-12, 6x4 raster staggered array, 1.403x1.555mm package, pitch 0.4mm; http://ww1.microchip.com/downloads/en/devicedoc/atmel-8235-8-bit-avr-microcontroller-attiny20_datasheet.pdf#page=208 +CSP 12 0.2x0.346333 +0 +12 +12 +Package_CSP +WLCSP-16_4x4_B2.17x2.32mm_P0.5mm +WLCSP-16, http://www.nxp.com/documents/data_sheet/LPC1102_1104.pdf, http://www.nxp.com/assets/documents/data/en/application-notes/AN3846.pdf +WLCSP-16 NXP +0 +16 +16 +Package_CSP +WLCSP-20_1.934x2.434mm_Layout4x5_P0.4mm +WLCSP-20, 4x5 raster, 1.934x2.434mm package, pitch 0.4mm; see section 36.2.3 of http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-42363-SAM-D11_Datasheet.pdf +BGA 20 0.4 +0 +20 +20 +Package_CSP +WLCSP-20_1.994x1.94mm_Layout4x5_P0.4mm +WLCSP-20, https://www.nxp.com/docs/en/package-information/98ASA00539D.pdf +WLCSP-20 +0 +20 +20 +Package_CSP +WLCSP-20_1.994x1.609mm_Layout5x4_P0.4mm +WLCSP-20, https://www.nxp.com/docs/en/package-information/98ASA00676D.pdf +WLCSP-20 +0 +20 +20 +Package_CSP +WLCSP-36_2.82x2.67mm_Layout6x6_P0.4mm +WLCSP-36, https://www.nxp.com/docs/en/package-information/98ASA00949D.pdf +WLCSP-36 +0 +36 +36 +Package_CSP +WLCSP-36_2.374x2.459mm_Layout6x6_P0.35mm +WLCSP-36, https://www.nxp.com/docs/en/package-information/98ASA00604D.pdf +WLCSP-36 +0 +36 +36 +Package_CSP +WLCSP-56_3.170x3.444mm_Layout7x8_P0.4mm +WLCSP-56, 7x8 raster, 3.170x3.444mm package, pitch 0.4mm; see section 48.2.4 of http://ww1.microchip.com/downloads/en/DeviceDoc/DS60001479B.pdf +BGA 56 0.4 +0 +56 +56 +Package_CSP +WLCSP-81_4.41x3.76mm_P0.4mm +WLCSP-81, 9x9, 0.4mm Pitch, http://www.st.com/content/ccc/resource/technical/document/technical_note/92/30/3c/a1/4c/bb/43/6f/DM00103228.pdf/files/DM00103228.pdf/jcr:content/translations/en.DM00103228.pdf +WLCSP ST +0 +81 +81 +Package_CSP +pSemi_CSP-16_1.64x2.04mm_P0.4mm +pSemi CSP-16 1.64x2.04x0.285mm (http://www.psemi.com/pdf/datasheets/pe29101ds.pdf, http://www.psemi.com/pdf/app_notes/an77.pdf) +psemi csp 16 +0 +16 +16 +Package_CSP +pSemi_CSP-16_1.64x2.04mm_P0.4mm_Pad0.18mm +pSemi CSP-16 1.64x2.04x0.285mm (http://www.psemi.com/pdf/datasheets/pe29101ds.pdf, http://www.psemi.com/pdf/app_notes/an77.pdf) +psemi csp 16 +0 +16 +16 +Package_DFN_QFN +AMS_QFN-4-1EP_2x2mm_P0.95mm_EP0.7x1.6mm +UFD Package, 4-Lead Plastic QFN (2mm x 2mm), http://ams.com/eng/content/download/950231/2267959/483138 +QFN 0.95 +0 +6 +5 +Package_DFN_QFN +Cypress_QFN-56-1EP_8x8mm_P0.5mm_EP6.22x6.22mm_ThermalVias +56-Lead Plastic Quad Flat, No Lead Package (ML) - 8x8x0.9 mm Body [QFN] (see datasheet at http://www.cypress.com/file/138911/download and app note at http://www.cypress.com/file/140006/download) +QFN 0.5 +0 +87 +57 +Package_DFN_QFN +DFN-6-1EP_1.2x1.2mm_P0.4mm_EP0.3x0.94mm_PullBack +DFN, 6 Pin (http://www.onsemi.com/pub/Collateral/NCP133-D.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_2x1.8mm_P0.5mm_EP1.2x1.6mm +DFN, 6 Pin (https://www.diodes.com/assets/Package-Files/U-DFN2018-6.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +7 +Package_DFN_QFN +DFN-6-1EP_2x2mm_P0.5mm_EP0.6x1.37mm +DFN, 6 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-dfn/05081703_C_DC6.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_2x2mm_P0.5mm_EP0.61x1.42mm +DC6 Package; 6-Lead Plastic DFN (2mm x 2mm) (see Linear Technology DFN_6_05-08-1703.pdf) +DFN 0.5 +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_2x2mm_P0.65mm_EP1x1.6mm +6-Lead Plastic Dual Flat, No Lead Package (MA) - 2x2x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.65 +0 +9 +7 +Package_DFN_QFN +DFN-6-1EP_3x2mm_P0.5mm_EP1.65x1.35mm +DFN, 6 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-dfn/(DCB6)%20DFN%2005-08-1715%20Rev%20A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +7 +Package_DFN_QFN +DFN-6-1EP_3x3mm_P0.95mm_EP1.7x2.6mm +DFN6 3*3 MM, 0.95 PITCH; CASE 506AH-01 (see ON Semiconductor 506AH.PDF) +DFN 0.95 +0 +13 +7 +Package_DFN_QFN +DFN-6-1EP_3x3mm_P1mm_EP1.5x2.4mm +DFN, 6 Pin (https://www.silabs.com/documents/public/data-sheets/Si7020-A20.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +7 +Package_DFN_QFN +DFN-6_1.3x1.2mm_P0.4mm +6-Lead Plastic DFN (1.3mm x 1.2mm) +DFN 0.4 +0 +6 +6 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.6x1.2mm +DFN, 8 Pin (https://www.qorvo.com/products/d/da001879), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.7x1.3mm +DFN, 8 Pin (https://www.onsemi.com/pub/Collateral/NUF4401MN-D.PDF#page=6), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.3mm +DFN, 8 Pin (https://www.onsemi.com/pub/Collateral/NB3N551-D.PDF#page=7), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.5mm +DFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-8127-AVR-8-bit-Microcontroller-ATtiny4-ATtiny5-ATtiny9-ATtiny10_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.6mm +DFN, 8 Pin (https://www.st.com/resource/en/datasheet/lm2903.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +10 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.5mm_EP1.05x1.75mm +DFN8 2x2, 0.5P; CASE 506CN (see ON Semiconductor 506CN.PDF) +DFN 0.5 +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x2mm_P0.45mm_EP0.64x1.38mm +DC8 Package 8-Lead Plastic DFN (2mm x 2mm) (see Linear Technology DFN_8_05-08-1719.pdf) +DFN 0.45 +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x3mm_P0.5mm_EP0.56x2.15mm +DFN, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/2451fg.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +11 +9 +Package_DFN_QFN +DFN-8-1EP_2x3mm_P0.5mm_EP0.61x2.2mm +DDB Package; 8-Lead Plastic DFN (3mm x 2mm) (see Linear Technology DFN_8_05-08-1702.pdf) +DFN 0.5 +0 +12 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.3x1.5mm +8-Lead Plastic Dual Flat, No Lead Package (8MA2) - 2x3x0.6 mm Body [UDFN] (see Atmel-8815-SEEPROM-AT24CS01-02-Datasheet.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.7x1.4mm +DFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_DFN_2x3x0_9_MC_C04-123C.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.36x1.46mm +8-Lead Plastic Dual Flat, No Lead Package (8MA2) - 2x3x0.6 mm Body (http://ww1.microchip.com/downloads/en/DeviceDoc/20005010F.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.5mm_EP1.75x1.45mm +8-Lead Plastic Dual Flat, No Lead Package (MC) - 2x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x2mm_P0.45mm_EP1.66x1.36mm +DCB Package 8-Lead Plastic DFN (2mm x 3mm) (see Linear Technology DFN_8_05-08-1718.pdf) +DFN 0.45 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x3mm_P0.5mm_EP1.66x2.38mm +DD Package; 8-Lead Plastic DFN (3mm x 3mm) (see Linear Technology DFN_8_05-08-1698.pdf) +DFN 0.5 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x3mm_P0.65mm_EP1.7x2.05mm +DFN, 8 Pin (http://www.ixysic.com/home/pdfs.nsf/www/IX4426-27-28.pdf/$file/IX4426-27-28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_3x3mm_P0.65mm_EP1.55x2.4mm +8-Lead Plastic Dual Flat, No Lead Package (MF) - 3x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.65 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_4x4mm_P0.8mm_EP2.3x3.24mm +DFN, 8 Pin (https://www.st.com/resource/en/datasheet/ld1086.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_4x4mm_P0.8mm_EP2.5x3.6mm +8-Lead Plastic Dual Flat, No Lead Package (MD) - 4x4x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.8 +0 +15 +9 +Package_DFN_QFN +DFN-8-1EP_4x4mm_P0.8mm_EP2.39x2.21mm +8-Lead Plastic Dual Flat, No Lead Package (MD) - 4x4x0.9 mm Body [DFN] (http://www.onsemi.com/pub/Collateral/NCP4308-D.PDF) +DFN 0.8 +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_6x5mm_P1.27mm_EP2x2mm +DD Package; 8-Lead Plastic DFN (6mm x 5mm) (see http://www.everspin.com/file/236/download) +dfn +0 +13 +9 +Package_DFN_QFN +DFN-8-1EP_6x5mm_P1.27mm_EP4x4mm +DD Package; 8-Lead Plastic DFN (6mm x 5mm) (see http://www.everspin.com/file/236/download) +dfn +0 +25 +9 +Package_DFN_QFN +DFN-8_2x2mm_P0.5mm +DFN8 2x2, 0.5P; No exposed pad - Ref http://pdfserv.maximintegrated.com/land_patterns/90-0349.PDF +DFN 0.5 +0 +8 +8 +Package_DFN_QFN +DFN-10-1EP_2x3mm_P0.5mm_EP0.64x2.4mm +DDB Package; 10-Lead Plastic DFN (3mm x 2mm) (see Linear Technology DFN_10_05-08-1722.pdf) +DFN 0.5 +0 +13 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.7x2.5mm +DFN, 10 Pin (https://www.monolithicpower.com/pub/media/document/MPQ2483_r1.05.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +15 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.55x2.48mm +10-Lead Plastic Dual Flat, No Lead Package (MF) - 3x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +15 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.65x2.38mm +DFN, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3471fb.pdf#page=15), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +15 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.65x2.38mm_ThermalVias +DFN, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3471fb.pdf#page=15), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +22 +11 +Package_DFN_QFN +DFN-10-1EP_3x3mm_P0.5mm_EP1.75x2.7mm +10-Lead Plastic Dual Flat No-Lead Package, 3x3mm Body (see Atmel Appnote 8826) +DFN 0.5 +0 +15 +11 +Package_DFN_QFN +DFN-10_2x2mm_P0.4mm +10-Lead Plastic DFN (2mm x 2mm) 0.40mm pitch +DFN 10 0.4mm +0 +10 +10 +Package_DFN_QFN +DFN-12-1EP_2x3mm_P0.45mm_EP0.64x2.4mm +DDB Package; 12-Lead Plastic DFN (3mm x 2mm) (see Linear Technology DFN_12_05-08-1723.pdf) +DFN 0.45 +0 +15 +13 +Package_DFN_QFN +DFN-12-1EP_3x3mm_P0.5mm_EP2.05x2.86mm +10-Lead Plastic Dual Flat, No Lead Package (MF) - 3x3x0.9 mm Body [DFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +17 +13 +Package_DFN_QFN +DFN-12-1EP_3x3mm_P0.45mm_EP1.66x2.38mm +DD Package; 12-Lead Plastic DFN (3mm x 3mm) (see Linear Technology DFN_12_05-08-1725.pdf) +DFN 0.45 +0 +17 +13 +Package_DFN_QFN +DFN-12-1EP_3x4mm_P0.5mm_EP1.7x3.3mm +DE/UE Package; 12-Lead Plastic DFN (4mm x 3mm) (see Linear Technology DFN_12_05-08-1695.pdf) +DFN 0.5 +0 +21 +13 +Package_DFN_QFN +DFN-12-1EP_4x4mm_P0.5mm_EP2.66x3.38mm +DF Package; 12-Lead Plastic DFN (4mm x 4mm) (see Linear Technology 05081733_A_DF12.pdf) +DFN 0.5 +0 +21 +13 +Package_DFN_QFN +DFN-12-1EP_4x4mm_P0.65mm_EP2.64x3.54mm +DFN12, 4x4, 0.65P; CASE 506CE (see ON Semiconductor 506CE.PDF) +DFN 0.65 +0 +21 +13 +Package_DFN_QFN +DFN-14-1EP_3x3mm_P0.4mm_EP1.78x2.35mm +DD Package; 14-Lead Plastic DFN (3mm x 3mm) (http://pdfserv.maximintegrated.com/land_patterns/90-0063.PDF) +DFN 0.40 +0 +19 +15 +Package_DFN_QFN +DFN-14-1EP_3x4.5mm_P0.65mm_EP1.65x4.25mm +14-lead very thin plastic quad flat, 3.0x4.5mm size, 0.65mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/14L_VDFN_4_5x3_0mm_JHA_C041198A.pdf) +VDFN DFN 0.65mm +0 +23 +15 +Package_DFN_QFN +DFN-14-1EP_3x4.5mm_P0.65mm_EP1.65x4.25mm_ThermalVias +14-lead very thin plastic quad flat, 3.0x4.5mm size, 0.65mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/14L_VDFN_4_5x3_0mm_JHA_C041198A.pdf) +VDFN DFN 0.65mm +0 +33 +15 +Package_DFN_QFN +DFN-14-1EP_3x4mm_P0.5mm_EP1.7x3.3mm +DE Package; 14-Lead Plastic DFN (4mm x 3mm) (see Linear Technology DFN_14_05-08-1708.pdf) +DFN 0.5 +0 +23 +15 +Package_DFN_QFN +DFN-14-1EP_4x4mm_P0.5mm_EP2.86x3.6mm +DFN14, 4x4, 0.5P; CASE 506CM (see ON Semiconductor 506CM.PDF) +DFN 0.5 +0 +23 +15 +Package_DFN_QFN +DFN-16-1EP_3x4mm_P0.45mm_EP1.7x3.3mm +DE Package; 16-Lead Plastic DFN (4mm x 3mm) (see Linear Technology DFN_16_05-08-1732.pdf) +DFN 0.45 +0 +25 +17 +Package_DFN_QFN +DFN-16-1EP_3x5mm_P0.5mm_EP1.66x4.4mm +DHC Package; 16-Lead Plastic DFN (5mm x 3mm) (see Linear Technology DFN_16_05-08-1706.pdf) +DFN 0.5 +0 +27 +17 +Package_DFN_QFN +DFN-16-1EP_4x5mm_P0.5mm_EP2.44x4.34mm +DHD Package; 16-Lead Plastic DFN (5mm x 4mm) (see Linear Technology 05081707_A_DHD16.pdf) +DFN 0.5 +0 +25 +17 +Package_DFN_QFN +DFN-16-1EP_5x5mm_P0.5mm_EP3.46x4mm +DH Package; 16-Lead Plastic DFN (5mm x 5mm) (see Linear Technology DFN_16_05-08-1709.pdf) +DFN 0.5 +0 +26 +17 +Package_DFN_QFN +DFN-18-1EP_3x5mm_P0.5mm_EP1.66x4.4mm +DHC Package; 18-Lead Plastic DFN (5mm x 3mm) (see Linear Technology 05081955_0_DHC18.pdf) +DFN 0.5 +0 +29 +19 +Package_DFN_QFN +DFN-18-1EP_4x5mm_P0.5mm_EP2.44x4.34mm +DHD Package; 18-Lead Plastic DFN (5mm x 4mm) (see Linear Technology DFN_18_05-08-1778.pdf) +DFN 0.5 +0 +27 +19 +Package_DFN_QFN +DFN-20-1EP_5x6mm_P0.5mm_EP3.24x4.24mm +DFN20, 6x5, 0.5P; CASE 505AB (see ON Semiconductor 505AB.PDF) +DFN 0.5 +0 +33 +21 +Package_DFN_QFN +DFN-22-1EP_5x6mm_P0.5mm_EP3.14x4.3mm +DFN22 6*5*0.9 MM, 0.5 P; CASE 506AF\xe2\x88\x9201 (see ON Semiconductor 506AF.PDF) +DFN 0.5 +0 +35 +23 +Package_DFN_QFN +DFN-24-1EP_4x7mm_P0.5mm_EP2.64x6.44mm +DKD Package; 24-Lead Plastic DFN (7mm x 4mm) (see Linear Technology DFN_24_05-08-1864.pdf) +DFN 0.5 +0 +35 +25 +Package_DFN_QFN +DFN-32-1EP_4x7mm_P0.4mm_EP2.64x6.44mm +DKD Package; 32-Lead Plastic DFN (7mm x 4mm) (see Linear Technology DFN_32_05-08-1734.pdf) +DFN 0.4 +0 +43 +33 +Package_DFN_QFN +DFN-44-1EP_5x8.9mm_P0.4mm_EP3.7x8.4mm +DFN44 8.9x5, 0.4P; CASE 506BU-01 (see ON Semiconductor 506BU.PDF) +DFN 0.4 +0 +63 +45 +Package_DFN_QFN +DFN-S-8-1EP_6x5mm_P1.27mm +8-Lead Plastic Dual Flat, No Lead Package (MF) - 6x5 mm Body [DFN-S] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 1.27 +0 +16 +9 +Package_DFN_QFN +Diodes_DFN1006-3 +DFN package size 1006 3 pins +DFN package size 1006 3 pins +0 +3 +3 +Package_DFN_QFN +Diodes_UDFN-10_1.0x2.5mm_P0.5mm +U-DFN2510-10 package used by Diodes Incorporated (https://www.diodes.com/assets/Package-Files/U-DFN2510-10-Type-CJ.pdf) +UDFN-10 U-DFN2510-10 Diodes +0 +10 +10 +Package_DFN_QFN +Diodes_UDFN2020-6_Type-F +U-DFN2020-6 (Type F) (https://www.diodes.com/assets/Package-Files/U-DFN2020-6-Type-F.pdf) +U-DFN2020-6 (Type F) +0 +8 +8 +Package_DFN_QFN +HVQFN-16-1EP_3x3mm_P0.5mm_EP1.5x1.5mm +HVQFN, 16 Pin (https://www.nxp.com/docs/en/package-information/SOT758-1.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +21 +17 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +29 +25 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +39 +25 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +34 +25 +Package_DFN_QFN +HVQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +HVQFN, 24 Pin (https://www.nxp.com/docs/en/package-information/SOT616-3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +HVQFN NoLead +0 +39 +25 +Package_DFN_QFN +Infineon_MLPQ-16-14-1EP_4x4mm_P0.5mm +MLPQ 32 leads, 7x7mm, 0.127mm stencil (https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +mlpq 32 7x7mm +0 +19 +15 +Package_DFN_QFN +Infineon_MLPQ-40-32-1EP_7x7mm_P0.5mm +MLPQ 32 leads, 7x7mm, 0.127mm stencil (https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +mlpq 32 7x7mm +0 +76 +33 +Package_DFN_QFN +Infineon_MLPQ-48-1EP_7x7mm_P0.5mm_EP5.55x5.55mm +MLPQ 48 leads, 7x7mm (https://www.infineon.com/dgdl/irs2093mpbf.pdf?fileId=5546d462533600a401535675fb892793) +mlpq 32 7x7mm +0 +113 +49 +Package_DFN_QFN +Infineon_MLPQ-48-1EP_7x7mm_P0.5mm_Pad5.15x5.15mm +MLPQ 48 leads, 7x7mm (https://www.infineon.com/dgdl/irs2052mpbf.pdf?fileId=5546d462533600a401535675d3b32788) +mlpq 32 7x7mm +0 +117 +49 +Package_DFN_QFN +Infineon_MLPQ-48-1EP_7x7mm_P0.5mm_Pad5.55x5.55mm +MLPQ 48 leads, 7x7mm (https://www.infineon.com/dgdl/irs2093mpbf.pdf?fileId=5546d462533600a401535675fb892793) +mlpq 32 7x7mm +0 +117 +49 +Package_DFN_QFN +Infineon_PQFN-22-15-4EP_6x5mm_P0.65mm +PQFN 22 leads, 5x6mm, 0.127mm stencil (https://www.infineon.com/dgdl/ir4301.pdf?fileId=5546d462533600a4015355d5fc691819, https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +pqfn 22 5x6mm +0 +56 +15 +Package_DFN_QFN +Infineon_PQFN-44-31-5EP_7x7mm_P0.5mm +PQFN 44 leads, 7x7mm, 0.127mm stencil (https://www.infineon.com/dgdl/ir4302.pdf?fileId=5546d462533600a4015355d602a9181d, https://www.infineon.com/dgdl/Infineon-AN1170-AN-v05_00-EN.pdf?fileId=5546d462533600a40153559ac3e51134) +pqfn 44 7x7mm +0 +125 +27 +Package_DFN_QFN +Linear_DE14MA +14-Lead Plastic DFN, 4mm x 3mm (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-dfn/05081731_C_DE14MA.pdf) +DFN 0.5 +0 +14 +14 +Package_DFN_QFN +Linear_UGK52_QFN-46-52 +Linear UKG52(46) package, QFN-52-1EP variant (see http://cds.linear.com/docs/en/datasheet/3886fe.pdf) +QFN 0.5 +0 +62 +47 +Package_DFN_QFN +MLF-6-1EP_1.6x1.6mm_P0.5mm_EP0.5x1.26mm +MLF, 6 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/mic5353.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +MLF NoLead +0 +9 +7 +Package_DFN_QFN +MLF-8-1EP_3x3mm_P0.65mm_EP1.55x2.3mm +8-Pin ePad 3mm x 3mm MLF - 3x3x0.85 mm Body (see Microchip datasheet http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf) +DFN MLF 0.65 +0 +12 +9 +Package_DFN_QFN +MLF-8-1EP_3x3mm_P0.65mm_EP1.55x2.3mm_ThermalVias +8-Pin ePad 3mm x 3mm MLF - 3x3x0.85 mm Body (see Microchip datasheet http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf) +DFN MLF 0.65 +0 +15 +9 +Package_DFN_QFN +MLF-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +MLF, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=263), generated with kicad-footprint-generator ipc_noLead_generator.py +MLF NoLead +0 +25 +21 +Package_DFN_QFN +MLF-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +MLF, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=263), generated with kicad-footprint-generator ipc_noLead_generator.py +MLF NoLead +0 +30 +21 +Package_DFN_QFN +MLPQ-16-1EP_4x4mm_P0.65mm_EP2.8x2.8mm +Micro Leadframe Package, 16 pin with exposed pad +MLPQ- 0.65 +0 +21 +17 +Package_DFN_QFN +Micrel_MLF-8-1EP_2x2mm_P0.5mm_EP0.8x1.3mm_ThermalVias +http://ww1.microchip.com/downloads/en/DeviceDoc/mic2290.pdf +mlf 8 2x2 mm +0 +14 +9 +Package_DFN_QFN +Microchip_8E-16 +16-Lead Quad Flat, No Lead Package (8E) - 4x4x0.9 mm Body [UQFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN Microchip 8E 16 +0 +20 +17 +Package_DFN_QFN +Microchip_DRQFN-44-1EP_5x5mm_P0.7mm_EP2.65x2.65mm +QFN, 44 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/44L_VQFN_5x5mm_Dual_Row_%5BS3B%5D_C04-21399a.pdf) +QFN dual row +0 +49 +45 +Package_DFN_QFN +Microchip_DRQFN-44-1EP_5x5mm_P0.7mm_EP2.65x2.65mm_ThermalVias +QFN, 44 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/44L_VQFN_5x5mm_Dual_Row_%5BS3B%5D_C04-21399a.pdf) +QFN dual row +0 +59 +45 +Package_DFN_QFN +Microchip_DRQFN-64-1EP_7x7mm_P0.65mm_EP4.1x4.1mm +QFN, 64 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_7x7_Dual_Row_%5BSVB%5D_C04-21420a.pdf) +QFN dual row +0 +74 +65 +Package_DFN_QFN +Microchip_DRQFN-64-1EP_7x7mm_P0.65mm_EP4.1x4.1mm_ThermalVias +QFN, 64 Pin, dual row (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_7x7_Dual_Row_%5BSVB%5D_C04-21420a.pdf) +QFN dual row +0 +91 +65 +Package_DFN_QFN +Microsemi_QFN-40-32-2EP_6x8mm_P0.5mm +40-Lead (32-Lead Populated) Plastic Quad Flat, No Lead Package - 6x8x0.9mm Body (https://www.microsemi.com/document-portal/doc_download/131677-pd70224-data-sheet) +QFN 0.5 +0 +92 +34 +Package_DFN_QFN +Mini-Circuits_DL805 +https://ww2.minicircuits.com/case_style/DL805.pdf +RF Switch +0 +11 +9 +Package_DFN_QFN +Mini-Circuits_FG873-4_3x3mm +Mini Circuits Case style FG (https://ww2.minicircuits.com/case_style/FG873.pdf) +FG873 +0 +4 +4 +Package_DFN_QFN +Nordic_AQFN-73-1EP_7x7mm_P0.5mm +http://infocenter.nordicsemi.com/index.jsp?topic=%2Fcom.nordic.infocenter.nrf52%2Fdita%2Fnrf52%2Fchips%2Fnrf52840.html +AQFN 7mm +0 +78 +74 +Package_DFN_QFN +OnSemi_DFN-8_2x2mm_P0.5mm +DFN8 2x2, 0.5P (https://www.onsemi.com/pub/Collateral/511AT.PDF) +DFN 0.5 +0 +8 +8 +Package_DFN_QFN +OnSemi_UDFN-8_1.2x1.8mm_P0.4mm +8-Lead Plastic Dual Flat, No Lead Package, 1.2x1.8x1.55 mm Body [UDFN] (See http://www.onsemi.com/pub/Collateral/NLSV2T244-D.PDF) +dfn udfn dual flat +0 +8 +8 +Package_DFN_QFN +OnSemi_VCT-28_3.5x3.5mm_P0.4mm +OnSemi VCT, 28 Pin (http://www.onsemi.com/pub/Collateral/601AE.PDF), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +OnSemi VCT DFN_QFN +0 +28 +28 +Package_DFN_QFN +Panasonic_HQFN-16-1EP_4x4mm_P0.65mm_EP2.9x2.9mm +Panasonic HQFN-16, 4x4x0.85mm (https://industrial.panasonic.com/content/data/SC/ds/ds7/c0/PKG_HQFN016-A-0404XZL_EN.pdf) +panasonic hqfn +0 +37 +17 +Package_DFN_QFN +Panasonic_HSON-8_8x8mm_P2.00mm +Panasonic HSON-8, 8x8x1.25mm (https://industrial.panasonic.com/content/data/SC/ds/ds7/c0/PKG_HSON008-A-0808XXI_EN.pdf) +panasonic hson +0 +27 +9 +Package_DFN_QFN +QFN-12-1EP_3x3mm_P0.5mm_EP1.65x1.65mm +QFN, 12 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_12_%2005-08-1855.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +17 +13 +Package_DFN_QFN +QFN-12-1EP_3x3mm_P0.5mm_EP1.65x1.65mm_ThermalVias +QFN, 12 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_12_%2005-08-1855.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +22 +13 +Package_DFN_QFN +QFN-12-1EP_3x3mm_P0.51mm_EP1.45x1.45mm +QFN, 12 Pin (https://ww2.minicircuits.com/case_style/DQ1225.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +17 +13 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm +QFN, 16 Pin (https://www.st.com/resource/en/datasheet/tsv521.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.7x1.7mm_ThermalVias +QFN, 16 Pin (http://www.cypress.com/file/46236/download), generated with kicad-footprint-generator ipc_dfn_qfn_generator.py +QFN DFN_QFN +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.9x1.9mm +QFN, 16 Pin (https://www.nxp.com/docs/en/package-information/98ASA00525D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.9x1.9mm_ThermalVias +QFN, 16 Pin (https://www.nxp.com/docs/en/package-information/98ASA00525D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm +QFN, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm_ThermalVias +QFN, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm +QFN, 16 Pin (https://www.onsemi.com/pub/Collateral/NCN4555-D.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm_ThermalVias +QFN, 16 Pin (https://www.onsemi.com/pub/Collateral/NCN4555-D.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.5mm_EP2.45x2.45mm +QFN, 16 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/isl8117.pdf#page=22), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.5mm_EP2.45x2.45mm_ThermalVias +QFN, 16 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/isl8117.pdf#page=22), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.1x2.1mm +QFN, 16 Pin (http://www.thatcorp.com/datashts/THAT_1580_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.1x2.1mm_ThermalVias +QFN, 16 Pin (http://www.thatcorp.com/datashts/THAT_1580_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.5x2.5mm +QFN, 16 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=266), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.5x2.5mm_ThermalVias +QFN, 16 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=266), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm +QFN, 16 Pin (https://www.allegromicro.com/~/media/Files/Datasheets/A4403-Datasheet.ashx), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm_PullBack +QFN, 16 Pin (https://ams.com/documents/20143/36005/AS5055A_DS000304_2-00.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm_PullBack_ThermalVias +QFN, 16 Pin (https://ams.com/documents/20143/36005/AS5055A_DS000304_2-00.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm_ThermalVias +QFN, 16 Pin (https://www.allegromicro.com/~/media/Files/Datasheets/A4403-Datasheet.ashx), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.15x2.15mm +QFN, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4001f.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_4x4mm_P0.65mm_EP2.15x2.15mm_ThermalVias +QFN, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4001f.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-16-1EP_5x5mm_P0.8mm_EP2.7x2.7mm +QFN, 16 Pin (http://www.intersil.com/content/dam/Intersil/documents/l16_/l16.5x5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +QFN-16-1EP_5x5mm_P0.8mm_EP2.7x2.7mm_ThermalVias +QFN, 16 Pin (http://www.intersil.com/content/dam/Intersil/documents/l16_/l16.5x5.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +QFN-20-1EP_3.5x3.5mm_P0.5mm_EP2x2mm +QFN, 20 Pin (http://www.ti.com/lit/ml/mpqf239/mpqf239.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3.5x3.5mm_P0.5mm_EP2x2mm_ThermalVias +QFN, 20 Pin (http://www.ti.com/lit/ml/mpqf239/mpqf239.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.4mm_EP1.65x1.65mm +QFN, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3553fc.pdf#page=34), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.4mm_EP1.65x1.65mm_ThermalVias +QFN, 20 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3553fc.pdf#page=34), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.45mm_EP1.6x1.6mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8235-8-bit-avr-microcontroller-attiny20_datasheet.pdf#page=212), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3x3mm_P0.45mm_EP1.6x1.6mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8235-8-bit-avr-microcontroller-attiny20_datasheet.pdf#page=212), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_3x4mm_P0.5mm_EP1.65x2.65mm +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_3x4mm_P0.5mm_EP1.65x2.65mm_ThermalVias +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +32 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=274), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.5x2.5mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=274), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc2535.pdf#page=164), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc2535.pdf#page=164), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.7x2.7mm +QFN, 20 Pin (https://www.silabs.com/documents/public/data-sheets/Si5351-B.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_4x4mm_P0.5mm_EP2.7x2.7mm_ThermalVias +QFN, 20 Pin (https://www.silabs.com/documents/public/data-sheets/Si5351-B.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +30 +21 +Package_DFN_QFN +QFN-20-1EP_4x5mm_P0.5mm_EP2.65x3.65mm +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1711.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +27 +21 +Package_DFN_QFN +QFN-20-1EP_4x5mm_P0.5mm_EP2.65x3.65mm_ThermalVias +QFN, 20 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1711.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +40 +21 +Package_DFN_QFN +QFN-20-1EP_5x5mm_P0.65mm_EP3.35x3.35mm +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=276), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +QFN-20-1EP_5x5mm_P0.65mm_EP3.35x3.35mm_ThermalVias +QFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=276), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +21 +Package_DFN_QFN +QFN-24-1EP_3x3mm_P0.4mm_EP1.75x1.6mm +QFN, 24 Pin (https://www.invensense.com/wp-content/uploads/2015/02/PS-MPU-9250A-01-v1.1.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_3x3mm_P0.4mm_EP1.75x1.6mm_ThermalVias +QFN, 24 Pin (https://www.invensense.com/wp-content/uploads/2015/02/PS-MPU-9250A-01-v1.1.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +34 +25 +Package_DFN_QFN +QFN-24-1EP_3x4mm_P0.4mm_EP1.65x2.65mm +QFN, 24 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +25 +Package_DFN_QFN +QFN-24-1EP_3x4mm_P0.4mm_EP1.65x2.65mm_ThermalVias +QFN, 24 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_20_05-08-1742.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +QFN, 24 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=278), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +QFN, 24 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=278), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.6mm +QFN, 24 Pin (https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.6mm_ThermalVias +QFN, 24 Pin (https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.7mm +QFN, 24 Pin (http://www.alfarzpp.lv/eng/sc/AS3330.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.7x2.7mm_ThermalVias +QFN, 24 Pin (http://www.alfarzpp.lv/eng/sc/AS3330.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm +QFN, 24 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/hmc431.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_ThermalVias +QFN, 24 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/hmc431.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.65x2.65mm +QFN, 24 Pin (http://www.cypress.com/file/46236/download), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_4x4mm_P0.5mm_EP2.65x2.65mm_ThermalVias +QFN, 24 Pin (http://www.cypress.com/file/46236/download), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_4x5mm_P0.5mm_EP2.65x3.65mm +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_24_05-08-1696.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +25 +Package_DFN_QFN +QFN-24-1EP_4x5mm_P0.5mm_EP2.65x3.65mm_ThermalVias +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_24_05-08-1696.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +44 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.2x3.2mm +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UH24)%20QFN%2005-08-1747%20Rev%20A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.2x3.2mm_ThermalVias +QFN, 24 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UH24)%20QFN%2005-08-1747%20Rev%20A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +51 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.4x3.4mm +QFN, 24 Pin (http://www.thatcorp.com/datashts/THAT_5173_Datasheet.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.4x3.4mm_ThermalVias +QFN, 24 Pin (http://www.thatcorp.com/datashts/THAT_5173_Datasheet.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.6x3.6mm +QFN, 24 Pin (https://www.nxp.com/docs/en/package-information/98ASA00734D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +34 +25 +Package_DFN_QFN +QFN-24-1EP_5x5mm_P0.65mm_EP3.6x3.6mm_ThermalVias +QFN, 24 Pin (https://www.nxp.com/docs/en/package-information/98ASA00734D.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +67 +25 +Package_DFN_QFN +QFN-28-1EP_3x6mm_P0.5mm_EP1.7x4.75mm +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081926_0_UDE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +29 +Package_DFN_QFN +QFN-28-1EP_3x6mm_P0.5mm_EP1.7x4.75mm_ThermalVias +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081926_0_UDE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +53 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.3x2.3mm +QFN, 28 Pin (http://www.issi.com/WW/pdf/31FL3731.pdf#page=21), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.3x2.3mm_ThermalVias +QFN, 28 Pin (http://www.issi.com/WW/pdf/31FL3731.pdf#page=21), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.4x2.4mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=280), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.4x2.4mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=280), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.6x2.6mm +QFN, 28 Pin (package code T2844-1; https://pdfserv.maximintegrated.com/package_dwgs/21-0139.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.4mm_EP2.6x2.6mm_ThermalVias +QFN, 28 Pin (package code T2844-1; https://pdfserv.maximintegrated.com/package_dwgs/21-0139.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +QFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +QFN-28-1EP_4x5mm_P0.5mm_EP2.65x3.65mm +QFN, 28 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/3555fe.pdf#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +29 +Package_DFN_QFN +QFN-28-1EP_4x5mm_P0.5mm_EP2.65x3.65mm_ThermalVias +QFN, 28 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/3555fe.pdf#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +48 +29 +Package_DFN_QFN +QFN-28-1EP_5x5mm_P0.5mm_EP3.35x3.35mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=283), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +29 +Package_DFN_QFN +QFN-28-1EP_5x5mm_P0.5mm_EP3.35x3.35mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=283), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +55 +29 +Package_DFN_QFN +QFN-28-1EP_5x6mm_P0.5mm_EP3.65x4.65mm +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081932_0_UHE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +41 +29 +Package_DFN_QFN +QFN-28-1EP_5x6mm_P0.5mm_EP3.65x4.65mm_ThermalVias +QFN, 28 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081932_0_UHE28.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +62 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.8x4.8mm +QFN, 28 Pin (https://www.semtech.com/uploads/documents/sx1272.pdf#page=125), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.8x4.8mm_ThermalVias +QFN, 28 Pin (https://www.semtech.com/uploads/documents/sx1272.pdf#page=125), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +71 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.25x4.25mm +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=289), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +38 +29 +Package_DFN_QFN +QFN-28-1EP_6x6mm_P0.65mm_EP4.25x4.25mm_ThermalVias +QFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=289), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +71 +29 +Package_DFN_QFN +QFN-28_4x4mm_P0.5mm +QFN, 28 Pin (http://www.st.com/resource/en/datasheet/stm32f031k6.pdf#page=90), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +28 +28 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.9x2.9mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8153-8-and-16-bit-avr-microcontroller-xmega-e-atxmega8e5-atxmega16e5-atxmega32e5_datasheet.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.9x2.9mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/atmel-8153-8-and-16-bit-avr-microcontroller-xmega-e-atxmega8e5-atxmega16e5-atxmega32e5_datasheet.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +33 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.65x2.65mm +QFN, 32 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/l32.4x4a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +QFN-32-1EP_4x4mm_P0.4mm_EP2.65x2.65mm_ThermalVias +QFN, 32 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/l32.4x4a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8008S.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.3x3.3mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002164B.pdf#page=68), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.3x3.3mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002164B.pdf#page=68), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.6x3.6mm +QFN, 32 Pin (http://infocenter.nordicsemi.com/pdf/nRF52810_PS_v1.1.pdf#page=468), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.6x3.6mm_ThermalVias +QFN, 32 Pin (http://infocenter.nordicsemi.com/pdf/nRF52810_PS_v1.1.pdf#page=468), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.7x3.7mm +QFN, 32 Pin (https://www.espressif.com/sites/default/files/documentation/0a-esp8285_datasheet_en.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.7x3.7mm_ThermalVias +QFN, 32 Pin (https://www.espressif.com/sites/default/files/documentation/0a-esp8285_datasheet_en.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.45x3.45mm +QFN, 32 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_32_05-08-1693.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.45x3.45mm_ThermalVias +QFN, 32 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_32_05-08-1693.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.65x3.65mm +QFN, 32 Pin (https://www.exar.com/ds/mxl7704.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +QFN-32-1EP_5x5mm_P0.5mm_EP3.65x3.65mm_ThermalVias +QFN, 32 Pin (https://www.exar.com/ds/mxl7704.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.7x4.7mm +QFN, 32 Pin (https://www.nxp.com/docs/en/data-sheet/LPC111X.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.7x4.7mm_ThermalVias +QFN, 32 Pin (https://www.nxp.com/docs/en/data-sheet/LPC111X.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.65x4.65mm +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-8209-8-bit%20AVR%20ATmega16M1-32M1-64M1_Datasheet.pdf#page=426), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP4.65x4.65mm_ThermalVias +QFN, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-8209-8-bit%20AVR%20ATmega16M1-32M1-64M1_Datasheet.pdf#page=426), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP5.4x5.4mm +QFN, 32 Pin (http://www.thatcorp.com/datashts/THAT_5171_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +33 +Package_DFN_QFN +QFN-32-1EP_7x7mm_P0.65mm_EP5.4x5.4mm_ThermalVias +QFN, 32 Pin (http://www.thatcorp.com/datashts/THAT_5171_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +33 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.1mm +QFN, 36 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.1mm_ThermalVias +QFN, 36 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +56 +37 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.6mm +QFN, 36 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UHE36)%20QFN%2005-08-1876%20Rev%20%C3%98.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +49 +37 +Package_DFN_QFN +QFN-36-1EP_5x6mm_P0.5mm_EP3.6x4.6mm_ThermalVias +QFN, 36 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/(UHE36)%20QFN%2005-08-1876%20Rev%20%C3%98.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +56 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP3.7x3.7mm +QFN, 36 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/36L_QFN_6x6_with_3_7x3_7_EP_Punch_Dimpled_4E_C04-0241A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP3.7x3.7mm_ThermalVias +QFN, 36 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/36L_QFN_6x6_with_3_7x3_7_EP_Punch_Dimpled_4E_C04-0241A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +63 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP4.1x4.1mm +QFN, 36 Pin (www.st.com/resource/en/datasheet/stm32f101t6.pdf#page=72), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +QFN-36-1EP_6x6mm_P0.5mm_EP4.1x4.1mm_ThermalVias +QFN, 36 Pin (www.st.com/resource/en/datasheet/stm32f101t6.pdf#page=72), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +63 +37 +Package_DFN_QFN +QFN-38-1EP_4x6mm_P0.4mm_EP2.65x4.65mm +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1750.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +39 +Package_DFN_QFN +QFN-38-1EP_4x6mm_P0.4mm_EP2.65x4.65mm_ThermalVias +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1750.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +56 +39 +Package_DFN_QFN +QFN-38-1EP_5x7mm_P0.5mm_EP3.15x5.15mm +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1701.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +54 +39 +Package_DFN_QFN +QFN-38-1EP_5x7mm_P0.5mm_EP3.15x5.15mm_ThermalVias +QFN, 38 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_38_05-08-1701.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +63 +39 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.6x3.6mm +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=297), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.6x3.6mm_ThermalVias +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=297), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +67 +41 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm +QFN, 40 Pin (http://www.issi.com/WW/pdf/31FL3736.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +QFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm_ThermalVias +QFN, 40 Pin (http://www.issi.com/WW/pdf/31FL3736.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +67 +41 +Package_DFN_QFN +QFN-40-1EP_6x6mm_P0.5mm_EP4.6x4.6mm +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=295), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +57 +41 +Package_DFN_QFN +QFN-40-1EP_6x6mm_P0.5mm_EP4.6x4.6mm_ThermalVias +QFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=295), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +83 +41 +Package_DFN_QFN +QFN-42-1EP_5x6mm_P0.4mm_EP3.7x4.7mm +QFN, 42 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081875_0_UHE42.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +55 +43 +Package_DFN_QFN +QFN-42-1EP_5x6mm_P0.4mm_EP3.7x4.7mm_ThermalVias +QFN, 42 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/05081875_0_UHE42.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +76 +43 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.2x5.2mm +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/2512S.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +61 +45 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.2x5.2mm_ThermalVias +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/2512S.pdf#page=17), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +87 +45 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.15x5.15mm +QFN, 44 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_44_05-08-1763.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +61 +45 +Package_DFN_QFN +QFN-44-1EP_7x7mm_P0.5mm_EP5.15x5.15mm_ThermalVias +QFN, 44 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_44_05-08-1763.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +87 +45 +Package_DFN_QFN +QFN-44-1EP_8x8mm_P0.65mm_EP6.45x6.45mm +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/39935c.pdf#page=152), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +70 +45 +Package_DFN_QFN +QFN-44-1EP_8x8mm_P0.65mm_EP6.45x6.45mm_ThermalVias +QFN, 44 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/39935c.pdf#page=152), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +45 +Package_DFN_QFN +QFN-44-1EP_9x9mm_P0.65mm_EP7.5x7.5mm +44-Lead Plastic Quad Flat, No Lead Package - 9x9 mm Body [QFN]; see section 10.3 of https://www.parallax.com/sites/default/files/downloads/P8X32A-Propeller-Datasheet-v1.4.0_0.pdf +QFN 0.65 +0 +49 +45 +Package_DFN_QFN +QFN-44-1EP_9x9mm_P0.65mm_EP7.5x7.5mm_ThermalVias +44-Lead Plastic Quad Flat, No Lead Package - 9x9 mm Body [QFN] with thermal vias; see section 10.3 of https://www.parallax.com/sites/default/files/downloads/P8X32A-Propeller-Datasheet-v1.4.0_0.pdf +QFN 0.65 +0 +55 +45 +Package_DFN_QFN +QFN-48-1EP_5x5mm_P0.35mm_EP3.7x3.7mm +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_5x5mm_P0.35mm_EP3.7x3.7mm_ThermalVias +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.2x4.2mm +QFN, 48 Pin (https://static.dev.sifive.com/SiFive-FE310-G000-datasheet-v1p5.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.2x4.2mm_ThermalVias +QFN, 48 Pin (https://static.dev.sifive.com/SiFive-FE310-G000-datasheet-v1p5.pdf#page=20), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.3x4.3mm +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.3x4.3mm_ThermalVias +QFN, 48 Pin (https://www.espressif.com/sites/default/files/documentation/esp32_datasheet_en.pdf#page=38), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +75 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.6x4.6mm +QFN, 48 Pin (http://infocenter.nordicsemi.com/pdf/nRF51822_PS_v3.3.pdf#page=67), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.6x4.6mm_ThermalVias +QFN, 48 Pin (http://infocenter.nordicsemi.com/pdf/nRF51822_PS_v3.3.pdf#page=67), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.66x4.66mm +QFN, 48 Pin (https://www.onsemi.com/pub/Collateral/485BA.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +58 +49 +Package_DFN_QFN +QFN-48-1EP_6x6mm_P0.4mm_EP4.66x4.66mm_ThermalVias +QFN, 48 Pin (https://www.onsemi.com/pub/Collateral/485BA.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.3x5.3mm +QFN, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2041_datasheet.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.3x5.3mm_ThermalVias +QFN, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2041_datasheet.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.6x5.6mm +QFN, 48 Pin (http://www.st.com/resource/en/datasheet/stm32f042k6.pdf#page=94), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.6x5.6mm_ThermalVias +QFN, 48 Pin (http://www.st.com/resource/en/datasheet/stm32f042k6.pdf#page=94), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm +QFN, 48 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_48_05-08-1704.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm_ThermalVias +QFN, 48 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_48_05-08-1704.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.45x5.45mm +QFN, 48 Pin (http://www.thatcorp.com/datashts/THAT_626x_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +QFN-48-1EP_7x7mm_P0.5mm_EP5.45x5.45mm_ThermalVias +QFN, 48 Pin (http://www.thatcorp.com/datashts/THAT_626x_Datasheet.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +49 +Package_DFN_QFN +QFN-48-1EP_8x8mm_P0.5mm_EP6.2x6.2mm +QFN, 48 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT232H.pdf#page=49), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +49 +Package_DFN_QFN +QFN-48-1EP_8x8mm_P0.5mm_EP6.2x6.2mm_ThermalVias +QFN, 48 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT232H.pdf#page=49), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +111 +49 +Package_DFN_QFN +QFN-52-1EP_7x8mm_P0.5mm_EP5.41x6.45mm +QFN, 52 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_52_05-08-1729.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +53 +Package_DFN_QFN +QFN-52-1EP_7x8mm_P0.5mm_EP5.41x6.45mm_ThermalVias +QFN, 52 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-qfn/QFN_52_05-08-1729.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +104 +53 +Package_DFN_QFN +QFN-56-1EP_7x7mm_P0.4mm_EP5.6x5.6mm +QFN, 56 Pin (http://www.cypress.com/file/416486/download#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_7x7mm_P0.4mm_EP5.6x5.6mm_ThermalVias +QFN, 56 Pin (http://www.cypress.com/file/416486/download#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.3x4.3mm +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002142A.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.3x4.3mm_ThermalVias +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002142A.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.5x5.2mm +QFN, 56 Pin (http://www.ti.com/lit/an/scea032/scea032.pdf#page=4), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.5x5.2mm_ThermalVias +QFN, 56 Pin (http://www.ti.com/lit/an/scea032/scea032.pdf#page=4), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP4.5x5.2mm_ThermalVias_TopTented +QFN, 56 Pin top tented version (manually modified). For information see: http://www.cypress.com/file/138911/download +QFN DFN_QFN +0 +115 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.6x5.6mm +QFN, 56 Pin (http://www.ti.com/lit/ds/symlink/tlc5957.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.6x5.6mm_ThermalVias +QFN, 56 Pin (http://www.ti.com/lit/ds/symlink/tlc5957.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.9x5.9mm +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001734B.pdf#page=50), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +73 +57 +Package_DFN_QFN +QFN-56-1EP_8x8mm_P0.5mm_EP5.9x5.9mm_ThermalVias +QFN, 56 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001734B.pdf#page=50), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +99 +57 +Package_DFN_QFN +QFN-64-1EP_8x8mm_P0.4mm_EP6.5x6.5mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_8x8_with%206_5x6_5%20EP_JXX_C04-0437A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_8x8mm_P0.4mm_EP6.5x6.5mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/64L_VQFN_8x8_with%206_5x6_5%20EP_JXX_C04-0437A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP3.8x3.8mm +QFN, 64 Pin (https://datasheet.lcsc.com/szlcsc/Realtek-Semicon-RTL8211EG-VB-CG_C69264.pdf#page=77), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP3.8x3.8mm_ThermalVias +QFN, 64 Pin (https://datasheet.lcsc.com/szlcsc/Realtek-Semicon-RTL8211EG-VB-CG_C69264.pdf#page=77), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +79 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.7x4.7mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/60001477A.pdf (page 1083)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.7x4.7mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/60001477A.pdf (page 1083)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.35x4.35mm +QFN, 64 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT2232H.pdf#page=57), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +74 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP4.35x4.35mm_ThermalVias +QFN, 64 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT2232H.pdf#page=57), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +91 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.4x5.4mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/70593d.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +81 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.4x5.4mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/70593d.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.45x5.45mm +QFN, 64 Pin (https://www.infineon.com/dgdl/Infineon-MA12040-DS-v01_00-EN.pdf?fileId=5546d46264a8de7e0164b7467a3d617c#page=81), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +81 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP5.45x5.45mm_ThermalVias +QFN, 64 Pin (https://www.infineon.com/dgdl/Infineon-MA12040-DS-v01_00-EN.pdf?fileId=5546d46264a8de7e0164b7467a3d617c#page=81), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP6x6mm +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/tusb8041.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +81 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP6x6mm_ThermalVias +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/tusb8041.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +107 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.3x7.3mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002304A.pdf (page 43)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.3x7.3mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00002304A.pdf (page 43)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.5x7.5mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc7593.pdf (page 432)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +101 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.5x7.5mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc7593.pdf (page 432)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +151 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.15x7.15mm +QFN, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/229321fa.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.15x7.15mm_ThermalVias +QFN, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/229321fa.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.25x7.25mm +64-Lead Plastic Quad Flat No-Lead Package, 9x9mm Body (see Atmel Appnote 8826) +QFN 0.5 +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.35x7.35mm +64-Lead Plastic Quad Flat, No Lead Package (MR) - 9x9x0.9 mm Body [QFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN 0.5 +0 +90 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.65x7.65mm +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-2549-8-bit-AVR-Microcontroller-ATmega640-1280-1281-2560-2561_datasheet.pdf (page 415)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +101 +65 +Package_DFN_QFN +QFN-64-1EP_9x9mm_P0.5mm_EP7.65x7.65mm_ThermalVias +QFN, 64 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-2549-8-bit-AVR-Microcontroller-ATmega640-1280-1281-2560-2561_datasheet.pdf (page 415)), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +151 +65 +Package_DFN_QFN +QFN-68-1EP_8x8mm_P0.4mm_EP5.2x5.2mm +QFN, 68 Pin (https://cdn.microsemi.com/documents/1bf6886f-5919-4508-a50b-b1dbf3fdf0f4/download/#page=98), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +85 +69 +Package_DFN_QFN +QFN-68-1EP_8x8mm_P0.4mm_EP5.2x5.2mm_ThermalVias +QFN, 68 Pin (https://cdn.microsemi.com/documents/1bf6886f-5919-4508-a50b-b1dbf3fdf0f4/download/#page=98), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +111 +69 +Package_DFN_QFN +QFN-72-1EP_10x10mm_P0.5mm_EP6x6mm +QFN, 72 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001682C.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +82 +73 +Package_DFN_QFN +QFN-72-1EP_10x10mm_P0.5mm_EP6x6mm_ThermalVias +QFN, 72 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001682C.pdf#page=70), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +135 +73 +Package_DFN_QFN +QFN-76-1EP_9x9mm_P0.4mm_EP3.8x3.8mm +QFN, 76 Pin (https://www.marvell.com/documents/bqcwxsoiqfjkcjdjhkvc/#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +86 +77 +Package_DFN_QFN +QFN-76-1EP_9x9mm_P0.4mm_EP3.8x3.8mm_ThermalVias +QFN, 76 Pin (https://www.marvell.com/documents/bqcwxsoiqfjkcjdjhkvc/#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +103 +77 +Package_DFN_QFN +Qorvo_DFN-8-1EP_2x2mm_P0.5mm +DFN 8 2x2mm, 0.5mm http://www.qorvo.com/products/d/da000896 +DFN 0.5 Qorvo 2x2mm +0 +9 +9 +Package_DFN_QFN +ROHM_DFN0604-3 +DFN package size 0604 3 pins +DFN package size 0604 3 pins +0 +3 +3 +Package_DFN_QFN +ST_UFQFPN-20_3x3mm_P0.5mm +UFQFPN 20-lead, 3 x 3 mm, 0.5 mm pitch, ultra thin fine pitch quad flat package (http://www.st.com/resource/en/datasheet/stm8s003f3.pdf) +UFQFPN 0.5 +0 +20 +20 +Package_DFN_QFN +ST_UQFN-6L_1.5x1.7mm_Pitch0.5mm +ST UQFN 6 pin 0.5mm Pitch http://www.st.com/resource/en/datasheet/ecmf02-2amx6.pdf +UQFN DFN 0.5 ST +0 +6 +6 +Package_DFN_QFN +SiliconLabs_QFN-20-1EP_3x3mm_P0.5mm_EP1.8x1.8mm +20-Lead Plastic Quad Flat, No Lead Package - 3x3 mm Body [QFN] with corner pads; see figure 8.2 of https://www.silabs.com/documents/public/data-sheets/efm8bb1-datasheet.pdf +QFN 0.5 +0 +25 +21 +Package_DFN_QFN +SiliconLabs_QFN-20-1EP_3x3mm_P0.5mm_EP1.8x1.8mm_ThermalVias +20-Lead Plastic Quad Flat, No Lead Package - 3x3 mm Body [QFN] with corner pads and thermal vias; see figure 8.2 of https://www.silabs.com/documents/public/data-sheets/efm8bb1-datasheet.pdf +QFN 0.5 +0 +31 +21 +Package_DFN_QFN +TDFN-6-1EP_2.5x2.5mm_P0.65mm_EP1.3x2mm +TDFN, 6 Pin (http://www.nve.com/Downloads/ab3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +11 +7 +Package_DFN_QFN +TDFN-6-1EP_2.5x2.5mm_P0.65mm_EP1.3x2mm_ThermalVias +TDFN, 6 Pin (http://www.nve.com/Downloads/ab3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +18 +7 +Package_DFN_QFN +TDFN-8-1EP_2x2mm_P0.5mm_EP0.8x1.2mm +TDFN, 8 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0168.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +13 +9 +Package_DFN_QFN +TDFN-8-1EP_3x2mm_P0.5mm_EP1.3x1.4mm +TDFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/MCP6V66-Family-Data-Sheet-DS20006266A.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +13 +9 +Package_DFN_QFN +TDFN-8-1EP_3x2mm_P0.5mm_EP1.80x1.65mm +8-lead plastic dual flat, 2x3x0.75mm size, 0.5mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_TDFN_2x3_MN_C04-0129E-MN.pdf) +TDFN DFN 0.5mm +0 +12 +9 +Package_DFN_QFN +TDFN-8-1EP_3x2mm_P0.5mm_EP1.80x1.65mm_ThermalVias +8-lead plastic dual flat, 2x3x0.75mm size, 0.5mm pitch (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_TDFN_2x3_MN_C04-0129E-MN.pdf) +TDFN DFN 0.5mm +0 +17 +9 +Package_DFN_QFN +TDFN-10-1EP_2x3mm_P0.5mm_EP0.9x2mm +TDFN, 10 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0429.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +13 +11 +Package_DFN_QFN +TDFN-10-1EP_2x3mm_P0.5mm_EP0.9x2mm_ThermalVias +TDFN, 10 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0429.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +16 +11 +Package_DFN_QFN +TDFN-12_2x3mm_P0.5mm +TDFN, 12 Pads, No exposed, http://www.st.com/resource/en/datasheet/stm6600.pdf +DFN +0 +12 +12 +Package_DFN_QFN +TDFN-14-1EP_3x3mm_P0.4mm_EP1.78x2.35mm +TDFN, 14 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0137.PDF (T1433-2C)), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +19 +15 +Package_DFN_QFN +TDFN-14-1EP_3x3mm_P0.4mm_EP1.78x2.35mm_ThermalVias +TDFN, 14 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0137.PDF (T1433-2C)), generated with kicad-footprint-generator ipc_noLead_generator.py +TDFN NoLead +0 +26 +15 +Package_DFN_QFN +TQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +TQFN, 16 Pin (https://www.diodes.com/assets/Datasheets/PI6C5946002.pdf#page=12), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_3x3mm_P0.5mm_EP1.23x1.23mm +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0136.PDF (T1633-5), https://pdfserv.maximintegrated.com/land_patterns/90-0032.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_3x3mm_P0.5mm_EP1.23x1.23mm_ThermalVias +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0136.PDF (T1633-5), https://pdfserv.maximintegrated.com/land_patterns/90-0032.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +26 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP2.29x2.29mm +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP2.29x2.29mm_ThermalVias +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +26 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP3.1x3.1mm +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-2)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +21 +17 +Package_DFN_QFN +TQFN-16-1EP_5x5mm_P0.8mm_EP3.1x3.1mm_ThermalVias +TQFN, 16 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T1655-2)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +31 +17 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.1x3.1mm +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +25 +21 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.1x3.1mm_ThermalVias +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +35 +21 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.25x3.25mm +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-5)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +25 +21 +Package_DFN_QFN +TQFN-20-1EP_5x5mm_P0.65mm_EP3.25x3.25mm_ThermalVias +TQFN, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2055-5)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +35 +21 +Package_DFN_QFN +TQFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_PullBack +TQFN, 24 Pin (https://ams.com/documents/20143/36005/AS1115_DS000206_1-00.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +29 +25 +Package_DFN_QFN +TQFN-24-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_PullBack_ThermalVias +TQFN, 24 Pin (https://ams.com/documents/20143/36005/AS1115_DS000206_1-00.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +39 +25 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP2.7x2.7mm +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +33 +29 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP2.7x2.7mm_ThermalVias +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-4)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +38 +29 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP3.25x3.25mm +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +33 +29 +Package_DFN_QFN +TQFN-28-1EP_5x5mm_P0.5mm_EP3.25x3.25mm_ThermalVias +TQFN, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T2855-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +43 +29 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP2.1x2.1mm +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-6)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +37 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP2.1x2.1mm_ThermalVias +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-6)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +42 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +37 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-3)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +47 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.4x3.4mm +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-9)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +37 +33 +Package_DFN_QFN +TQFN-32-1EP_5x5mm_P0.5mm_EP3.4x3.4mm_ThermalVias +TQFN, 32 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T3255-9)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +47 +33 +Package_DFN_QFN +TQFN-40-1EP_5x5mm_P0.4mm_EP3.5x3.5mm +TQFN, 40 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T4055-1)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +45 +41 +Package_DFN_QFN +TQFN-40-1EP_5x5mm_P0.4mm_EP3.5x3.5mm_ThermalVias +TQFN, 40 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0140.PDF (T4055-1)), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +55 +41 +Package_DFN_QFN +TQFN-48-1EP_7x7mm_P0.5mm_EP5.1x5.1mm +TQFN, 48 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0144.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +58 +49 +Package_DFN_QFN +TQFN-48-1EP_7x7mm_P0.5mm_EP5.1x5.1mm_ThermalVias +TQFN, 48 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0144.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +TQFN NoLead +0 +75 +49 +Package_DFN_QFN +Texas_DRB0008A +DFN-8, 3x3x1mm, http://www.ti.com/lit/ds/symlink/ucc24610.pdf +DRB0008A +0 +23 +9 +Package_DFN_QFN +Texas_MOF0009A +Texas Instruments, QFM MOF0009A, 6x8x2mm (http://www.ti.com/lit/ml/mpsi063a/mpsi063a.pdf) +ti qfm mof0009a +0 +24 +9 +Package_DFN_QFN +Texas_QFN-41_10x16mm +QFN, 41 Pin (http://www.ti.com/lit/ml/mpqf506/mpqf506.pdf) +QFN DFN_QFN +0 +65 +41 +Package_DFN_QFN +Texas_R-PUQFN-N10 +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=MPQF186&fileType=pdf +Texas_R-PUQFN-N10 +0 +10 +10 +Package_DFN_QFN +Texas_R-PWQFN-N28_EP2.1x3.1mm +QFN, 28 Pin (http://www.ti.com/lit/ds/symlink/tps51363.pdf#page=29), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +33 +29 +Package_DFN_QFN +Texas_R-PWQFN-N28_EP2.1x3.1mm_ThermalVias +QFN, 28 Pin (http://www.ti.com/lit/ds/symlink/tps51363.pdf#page=29), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +43 +29 +Package_DFN_QFN +Texas_RGE0024C_EP2.1x2.1mm +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/pca9548a.pdf#page=37), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_RGE0024C_EP2.1x2.1mm_ThermalVias +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/pca9548a.pdf#page=37), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_RGE0024H_EP2.7x2.7mm +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_RGE0024H_EP2.7x2.7mm_ThermalVias +Texas QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_RGV_S-PVQFN-N16_EP2.1x2.1mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ina3221.pdf#page=44), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +Texas_RGV_S-PVQFN-N16_EP2.1x2.1mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ina3221.pdf#page=44), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_RGY_R-PVQFN-N24_EP2.05x3.1mm +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq24133.pdf#page=40) +QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_RGY_R-PVQFN-N24_EP2.05x3.1mm_ThermalVias +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq24133.pdf#page=40) +QFN NoLead +0 +36 +25 +Package_DFN_QFN +Texas_RNN0018A +Texas Instruments, VQFN-HR RNN0018A (http://www.ti.com/lit/ds/symlink/tps568215.pdf) +ti vqfn-hr rnn0018a +0 +26 +18 +Package_DFN_QFN +Texas_RUM0016A_EP2.6x2.6mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/lmh0074.pdf#page=13), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +Texas_RUM0016A_EP2.6x2.6mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/lmh0074.pdf#page=13), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_RWH0032A +Texas Instruments, RWH0032A, 8x8x0.9mm (http://www.ti.com/lit/ds/snosd10c/snosd10c.pdf) +ti rwh0032a +0 +71 +33 +Package_DFN_QFN +Texas_RWH0032A_ThermalVias +Texas Instruments, RWH0032A, 8x8x0.9mm (http://www.ti.com/lit/ds/snosd10c/snosd10c.pdf) +ti rwh0032a +0 +94 +33 +Package_DFN_QFN +Texas_R_PUQFN-N12 +Texas_R_PUQFN-N12 http://www.ti.com/lit/ds/symlink/txb0104.pdf +Texas_R_PUQFN-N12 +0 +13 +12 +Package_DFN_QFN +Texas_S-PDSO-N10_EP1.2x2mm +DFN, 10 Pin (http://www.ti.com/lit/ds/symlink/tps7a91.pdf#page=30), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +15 +11 +Package_DFN_QFN +Texas_S-PDSO-N10_EP1.2x2mm_ThermalVias +DFN, 10 Pin (http://www.ti.com/lit/ds/symlink/tps7a91.pdf#page=30), generated with kicad-footprint-generator ipc_noLead_generator.py +DFN NoLead +0 +22 +11 +Package_DFN_QFN +Texas_S-PVQFN-N14 +Texas_S-PVQFN-N14 http://www.ti.com/lit/ds/symlink/txb0104.pdf +Texas_S-PVQFN-N14_4.3x4.3_Pitch0.5mm_ThermalPad +0 +19 +15 +Package_DFN_QFN +Texas_S-PVQFN-N14_ThermalVias +Texas_S-PVQFN-N14_ThermalVias http://www.ti.com/lit/ds/symlink/txb0104.pdf +Texas_S-PVQFN-N14_ThermalVias +0 +24 +15 +Package_DFN_QFN +Texas_S-PVQFN-N16_EP2.7x2.7mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/msp430g2001.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +26 +17 +Package_DFN_QFN +Texas_S-PVQFN-N16_EP2.7x2.7mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/msp430g2001.pdf#page=43), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.4x2.4mm +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/cc1101.pdf#page=101), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.4x2.4mm_ThermalVias +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/cc1101.pdf#page=101), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.7x2.7mm +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/drv8662.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP2.7x2.7mm_ThermalVias +QFN, 20 Pin (http://www.ti.com/lit/ds/symlink/drv8662.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +35 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP3.15x3.15mm +QFN, 20 Pin (www.ti.com/lit/ds/symlink/tps7a7200.pdf#page=36), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +25 +21 +Package_DFN_QFN +Texas_S-PVQFN-N20_EP3.15x3.15mm_ThermalVias +QFN, 20 Pin (www.ti.com/lit/ds/symlink/tps7a7200.pdf#page=36), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +21 +Package_DFN_QFN +Texas_S-PVQFN-N24_EP2.1x2.1mm +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5720.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_S-PVQFN-N24_EP2.1x2.1mm_ThermalVias +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5720.pdf#page=108), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_S-PVQFN-N32_EP3.45x3.45mm +QFN, 32 Pin (http://www.ti.com/lit/ds/symlink/msp430f1122.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +42 +33 +Package_DFN_QFN +Texas_S-PVQFN-N32_EP3.45x3.45mm_ThermalVias +QFN, 32 Pin (http://www.ti.com/lit/ds/symlink/msp430f1122.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +59 +33 +Package_DFN_QFN +Texas_S-PVQFN-N36_EP4.4x4.4mm +QFN, 36 Pin (http://www.ti.com/lit/ds/slvsba5d/slvsba5d.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +46 +37 +Package_DFN_QFN +Texas_S-PVQFN-N36_EP4.4x4.4mm_ThermalVias +QFN, 36 Pin (http://www.ti.com/lit/ds/slvsba5d/slvsba5d.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +79 +37 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP2.9x2.9mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5731.pdf#page=111 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +45 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP2.9x2.9mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430fr5731.pdf#page=111 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +55 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP3.52x2.62mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/drv8308.pdf#page=56 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP3.52x2.62mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/drv8308.pdf#page=56 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +60 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.6x4.6mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/dac7750.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.6x4.6mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/dac7750.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +83 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.15x4.15mm +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430g2755.pdf#page=70 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +50 +41 +Package_DFN_QFN +Texas_S-PVQFN-N40_EP4.15x4.15mm_ThermalVias +QFN, 40 Pin (http://www.ti.com/lit/ds/symlink/msp430g2755.pdf#page=70 JEDEC MO-220 variation VJJD-2), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +83 +41 +Package_DFN_QFN +Texas_S-PVQFN-N48_EP5.15x5.15mm +QFN, 48 Pin (http://www.ti.com/lit/ds/symlink/msp430f5232.pdf#page=111), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +65 +49 +Package_DFN_QFN +Texas_S-PVQFN-N48_EP5.15x5.15mm_ThermalVias +QFN, 48 Pin (http://www.ti.com/lit/ds/symlink/msp430f5232.pdf#page=111), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +111 +49 +Package_DFN_QFN +Texas_S-PVQFN-N64_EP4.25x4.25mm +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/msp430f5217.pdf#page=120), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +69 +65 +Package_DFN_QFN +Texas_S-PVQFN-N64_EP4.25x4.25mm_ThermalVias +QFN, 64 Pin (http://www.ti.com/lit/ds/symlink/msp430f5217.pdf#page=120), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +127 +65 +Package_DFN_QFN +Texas_S-PWQFN-N16_EP2.1x2.1mm +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/drv8801.pdf#page=31 MO-220 variation VGGC), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +21 +17 +Package_DFN_QFN +Texas_S-PWQFN-N16_EP2.1x2.1mm_ThermalVias +QFN, 16 Pin (http://www.ti.com/lit/ds/symlink/drv8801.pdf#page=31 MO-220 variation VGGC), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +31 +17 +Package_DFN_QFN +Texas_S-PWQFN-N20 +20-Pin Plastic Quad Flatpack No-Lead Package, Body 3.0x3.0x0.8mm, Texas Instruments (http://www.ti.com/lit/ds/symlink/tps22993.pdf) +QFN 0.4 +0 +24 +20 +Package_DFN_QFN +Texas_S-PWQFN-N24_EP2.7x2.7mm +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq25601.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +29 +25 +Package_DFN_QFN +Texas_S-PWQFN-N24_EP2.7x2.7mm_ThermalVias +QFN, 24 Pin (http://www.ti.com/lit/ds/symlink/bq25601.pdf#page=54), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +39 +25 +Package_DFN_QFN +Texas_S-PWQFN-N32_EP2.8x2.8mm +QFN, 32 Pin (https://www.ti.com/lit/ds/symlink/bq25703a.pdf#page=90), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +37 +33 +Package_DFN_QFN +Texas_S-PWQFN-N32_EP2.8x2.8mm_ThermalVias +QFN, 32 Pin (https://www.ti.com/lit/ds/symlink/bq25703a.pdf#page=90), generated with kicad-footprint-generator ipc_noLead_generator.py +QFN NoLead +0 +47 +33 +Package_DFN_QFN +Texas_S-PWQFN-N100_EP5.5x5.5mm +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/lit/ds/sllse76m/sllse76m.pdf +MultiRow QFN +0 +114 +105 +Package_DFN_QFN +Texas_S-PWQFN-N100_EP5.5x5.5mm_ThermalVias +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/lit/ds/sllse76m/sllse76m.pdf +MultiRow QFN +0 +131 +105 +Package_DFN_QFN +Texas_S-PX2QFN-14 +Texas QFN, 14 Pin (http://www.ti.com/lit/ds/symlink/tlv9004.pdf#page=64), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas QFN NoLead +0 +14 +14 +Package_DFN_QFN +Texas_VQFN-RHL-20 +http://www.ti.com/lit/ds/symlink/bq51050b.pdf +RHL0020A +0 +33 +21 +Package_DFN_QFN +Texas_VQFN-RHL-20_ThermalVias +http://www.ti.com/lit/ds/symlink/bq51050b.pdf +RHL0020A +0 +41 +21 +Package_DFN_QFN +Texas_VSON-HR-8_1.5x2mm_P0.5mm +Texas VSON-HR, 8 Pin (http://www.ti.com/lit/ds/symlink/tps62823.pdf#page=29), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas VSON-HR NoLead +0 +8 +8 +Package_DFN_QFN +Texas_WQFN-MR-100_3x3-DapStencil +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=mpqf258&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=LPPD235&fileType=pdf +MultiRow QFN +0 +113 +105 +Package_DFN_QFN +Texas_WQFN-MR-100_ThermalVias_3x3-DapStencil +http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=szza059&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=mpqf258&fileType=pdf,http://www.ti.com/general/docs/lit/getliterature.tsp?baseLiteratureNumber=LPPD235&fileType=pdf +MultiRow QFN +0 +126 +105 +Package_DFN_QFN +Texas_X2QFN-12_1.6x1.6mm_P0.4mm +Texas X2QFN, 12 Pin (http://www.ti.com/lit/ml/mpqf391c/mpqf391c.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas X2QFN NoLead +0 +12 +12 +Package_DFN_QFN +UDFN-4-1EP_1x1mm_P0.65mm_EP0.48x0.48mm +UDFN-4_1x1mm_P0.65mm, http://ww1.microchip.com/downloads/en/DeviceDoc/MIC550x-300mA-Single-Output-LDO-in-Small-Packages-DS20006006A.pdf +UDFN-4_1x1mm_P0.65mm +0 +5 +5 +Package_DFN_QFN +UDFN-9_1.0x3.8mm_P0.5mm +9-pin UDFN package, 1.0x3.8mm, (Ref: https://katalog.we-online.de/pbs/datasheet/824014881.pdf) +UDFN SMD +0 +9 +9 +Package_DFN_QFN +UDFN-10_1.35x2.6mm_P0.5mm +http://www.st.com/content/ccc/resource/technical/document/datasheet/f2/11/8a/ed/40/31/40/56/DM00088292.pdf/files/DM00088292.pdf/jcr:content/translations/en.DM00088292.pdf +UDFN 0.5 uQFN +0 +10 +10 +Package_DFN_QFN +UQFN-10_1.3x1.8mm_P0.4mm +UQFN, 10 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001725D.pdf (Page 9)), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +10 +10 +Package_DFN_QFN +UQFN-10_1.4x1.8mm_P0.4mm +UQFN 10pin, https://www.onsemi.com/pub/Collateral/488AT.PDF +UQFN-10_1.4x1.8mm_P0.4mm +0 +10 +10 +Package_DFN_QFN +UQFN-10_1.6x2.1mm_P0.5mm +UQFN, 10 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/00001725D.pdf (Page 12)), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +10 +10 +Package_DFN_QFN +UQFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm +16-Lead Ultra Thin Quad Flat, No Lead Package (UC) - 3x3x0.5 mm Body [UQFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN 0.5 +0 +21 +17 +Package_DFN_QFN +UQFN-16-1EP_4x4mm_P0.65mm_EP2.6x2.6mm +UQFN, 16 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/16L_UQFN_4x4x0_5mm_JQ_C04257A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +21 +17 +Package_DFN_QFN +UQFN-16-1EP_4x4mm_P0.65mm_EP2.6x2.6mm_ThermalVias +UQFN, 16 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/16L_UQFN_4x4x0_5mm_JQ_C04257A.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +31 +17 +Package_DFN_QFN +UQFN-16-1EP_4x4mm_P0.65mm_EP2.7x2.7mm +16-Lead Ultra Thin Plastic Quad Flat, No Lead Package (JQ) - 4x4x0.5 mm Body [UQFN]; (see Microchip Packaging Specification 00000049BS.pdf) +QFN 0.65 +0 +21 +17 +Package_DFN_QFN +UQFN-20-1EP_3x3mm_P0.4mm_EP1.85x1.85mm +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=332), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +25 +21 +Package_DFN_QFN +UQFN-20-1EP_3x3mm_P0.4mm_EP1.85x1.85mm_ThermalVias +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=332), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +30 +21 +Package_DFN_QFN +UQFN-20-1EP_4x4mm_P0.5mm_EP2.8x2.8mm +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/40001839B.pdf#page=464), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +25 +21 +Package_DFN_QFN +UQFN-20-1EP_4x4mm_P0.5mm_EP2.8x2.8mm_ThermalVias +UQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/40001839B.pdf#page=464), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +35 +21 +Package_DFN_QFN +UQFN-28-1EP_4x4mm_P0.4mm_EP2.35x2.35mm +UQFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=338), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +33 +29 +Package_DFN_QFN +UQFN-28-1EP_4x4mm_P0.4mm_EP2.35x2.35mm_ThermalVias +UQFN, 28 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=338), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +43 +29 +Package_DFN_QFN +UQFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm +UQFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=345), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +50 +41 +Package_DFN_QFN +UQFN-40-1EP_5x5mm_P0.4mm_EP3.8x3.8mm_ThermalVias +UQFN, 40 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=345), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +67 +41 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.45x4.45mm +UQFN, 48 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=347), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +58 +49 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.45x4.45mm_ThermalVias +UQFN, 48 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=347), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +75 +49 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.62x4.62mm +UQFN, 48 Pin (https://github.com/KiCad/kicad-symbols/pull/1189#issuecomment-449506354), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +53 +49 +Package_DFN_QFN +UQFN-48-1EP_6x6mm_P0.4mm_EP4.62x4.62mm_ThermalVias +UQFN, 48 Pin (https://github.com/KiCad/kicad-symbols/pull/1189#issuecomment-449506354), generated with kicad-footprint-generator ipc_noLead_generator.py +UQFN NoLead +0 +75 +49 +Package_DFN_QFN +VDFN-8-1EP_2x2mm_P0.5mm_EP0.9x1.7mm +8-Lead Very Thin Dual Flatpack No-Lead (LZ) - 2x3x0.9 mm Body [VDFN] (see Microchip Packaging Specification 00000049BS.pdf) +DFN 0.5 +0 +11 +9 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/cdclvp1102.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm_ThermalVias +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/cdclvp1102.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.8x1.8mm +VQFN, 16 Pin (https://www.st.com/resource/en/datasheet/stspin220.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.8x1.8mm_ThermalVias +VQFN, 16 Pin (https://www.st.com/resource/en/datasheet/stspin220.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm +VQFN, 16 Pin (http://www.ti.com/lit/ds/sbos354a/sbos354a.pdf, JEDEC MO-220 variant VEED-6), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.45x1.45mm_ThermalVias +VQFN, 16 Pin (http://www.ti.com/lit/ds/sbos354a/sbos354a.pdf, JEDEC MO-220 variant VEED-6), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.68x1.68mm +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/tlv62095.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +21 +17 +Package_DFN_QFN +VQFN-16-1EP_3x3mm_P0.5mm_EP1.68x1.68mm_ThermalVias +VQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/tlv62095.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +26 +17 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.4mm_EP1.7x1.7mm +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/20%20Lead%20VQFN%203x3x0_9mm_1_7EP%20U2B%20C04-21496a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +25 +21 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.4mm_EP1.7x1.7mm_ThermalVias +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/20%20Lead%20VQFN%203x3x0_9mm_1_7EP%20U2B%20C04-21496a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +30 +21 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.45mm_EP1.55x1.55mm +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=264), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +25 +21 +Package_DFN_QFN +VQFN-20-1EP_3x3mm_P0.45mm_EP1.55x1.55mm_ThermalVias +VQFN, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc8246.pdf#page=264), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +30 +21 +Package_DFN_QFN +VQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm +VQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430f1101a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +34 +25 +Package_DFN_QFN +VQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm_ThermalVias +VQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/msp430f1101a.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +39 +25 +Package_DFN_QFN +VQFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm +VQFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-9505-AT42-QTouch-BSW-AT42QT1060_Datasheet.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +33 +29 +Package_DFN_QFN +VQFN-28-1EP_4x4mm_P0.45mm_EP2.4x2.4mm_ThermalVias +VQFN, 28 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/Atmel-9505-AT42-QTouch-BSW-AT42QT1060_Datasheet.pdf#page=28), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +43 +29 +Package_DFN_QFN +VQFN-28-1EP_4x5mm_P0.5mm_EP2.55x3.55mm +VQFN, 28 Pin (http://www.ti.com/lit/ds/symlink/lm5175.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +35 +29 +Package_DFN_QFN +VQFN-28-1EP_4x5mm_P0.5mm_EP2.55x3.55mm_ThermalVias +VQFN, 28 Pin (http://www.ti.com/lit/ds/symlink/lm5175.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +48 +29 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +VQFN, 32 Pin (http://ww1.microchip.com/downloads/en/devicedoc/atmel-9520-at42-qtouch-bsw-at42qt1110_datasheet.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +37 +33 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm_ThermalVias +VQFN, 32 Pin (http://ww1.microchip.com/downloads/en/devicedoc/atmel-9520-at42-qtouch-bsw-at42qt1110_datasheet.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +47 +33 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.5x3.5mm +VQFN, 32 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT4222H.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +37 +33 +Package_DFN_QFN +VQFN-32-1EP_5x5mm_P0.5mm_EP3.5x3.5mm_ThermalVias +VQFN, 32 Pin (https://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT4222H.pdf#page=40), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +47 +33 +Package_DFN_QFN +VQFN-46-1EP_5x6mm_P0.4mm_EP2.8x3.8mm +VQFN, 46 Pin (http://www.ti.com/lit/ds/symlink/lp5036.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +53 +47 +Package_DFN_QFN +VQFN-46-1EP_5x6mm_P0.4mm_EP2.8x3.8mm_ThermalVias +VQFN, 46 Pin (http://www.ti.com/lit/ds/symlink/lp5036.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +66 +47 +Package_DFN_QFN +VQFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm +VQFN, 48 Pin (http://www.ti.com/lit/ds/symlink/cc1312r.pdf#page=48), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +53 +49 +Package_DFN_QFN +VQFN-48-1EP_7x7mm_P0.5mm_EP5.15x5.15mm_ThermalVias +VQFN, 48 Pin (http://www.ti.com/lit/ds/symlink/cc1312r.pdf#page=48), generated with kicad-footprint-generator ipc_noLead_generator.py +VQFN NoLead +0 +79 +49 +Package_DFN_QFN +WDFN-8-1EP_2x2.2mm_P0.5mm_EP0.80x0.54 +https://www.onsemi.com/pub/Collateral/511BN.PDF +WDFN-8 1EP 2.2X2.0 0.5P +0 +9 +9 +Package_DFN_QFN +WDFN-8-1EP_3x2mm_P0.5mm_EP1.3x1.4mm +WDFN, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/8L_TDFN_2x3_MNY_C04-0129E-MNY.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +13 +9 +Package_DFN_QFN +WDFN-8-1EP_4x3mm_P0.65mm_EP2.4x1.8mm +WDFN, 8 Pin (https://www.onsemi.com/pub/Collateral/509AF.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +13 +9 +Package_DFN_QFN +WDFN-8-1EP_4x3mm_P0.65mm_EP2.4x1.8mm_ThermalVias +WDFN, 8 Pin (https://www.onsemi.com/pub/Collateral/509AF.PDF), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +20 +9 +Package_DFN_QFN +WDFN-8_2x2mm_P0.5mm +DFN8 2x2, 0.5P; No exposed pad (http://www.onsemi.com/pub/Collateral/NCP4308-D.PDF) +DFN 0.5 +0 +8 +8 +Package_DFN_QFN +WDFN-12-1EP_3x3mm_P0.45mm_EP1.7x2.5mm +WDFN, 12 Pin (https://www.diodes.com/assets/Datasheets/PAM2306.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WDFN NoLead +0 +17 +13 +Package_DFN_QFN +WQFN-14-1EP_2.5x2.5mm_P0.5mm_EP1.45x1.45mm +WQFN, 14 Pin (https://www.onsemi.com/pub/Collateral/FUSB302B-D.PDF#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +19 +15 +Package_DFN_QFN +WQFN-14-1EP_2.5x2.5mm_P0.5mm_EP1.45x1.45mm_ThermalVias +WQFN, 14 Pin (https://www.onsemi.com/pub/Collateral/FUSB302B-D.PDF#page=32), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +24 +15 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm +WQFN, 16 Pin (https://www.ti.com/lit/ds/symlink/tpa6132a2.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +21 +17 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.6x1.6mm_ThermalVias +WQFN, 16 Pin (https://www.ti.com/lit/ds/symlink/tpa6132a2.pdf#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +26 +17 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm +WQFN, 16 Pin (https://www.onsemi.com/pub/Collateral/FUSB307B-D.PDF#page=56), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +21 +17 +Package_DFN_QFN +WQFN-16-1EP_3x3mm_P0.5mm_EP1.75x1.75mm_ThermalVias +WQFN, 16 Pin (https://www.onsemi.com/pub/Collateral/FUSB307B-D.PDF#page=56), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +26 +17 +Package_DFN_QFN +WQFN-16-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +WQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +21 +17 +Package_DFN_QFN +WQFN-16-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +WQFN, 16 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=59), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +31 +17 +Package_DFN_QFN +WQFN-20-1EP_2.5x4.5mm_P0.5mm_EP1x2.9mm +http://www.onsemi.com/pub/Collateral/510CD.PDF +WQFN-20 4.5mm 2.5mm 0.5mm +0 +24 +21 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/lm26480.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +29 +25 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.6x2.6mm_ThermalVias +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/lm26480.pdf#page=39), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +39 +25 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/ts3a27518e.pdf#page=33), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +29 +25 +Package_DFN_QFN +WQFN-24-1EP_4x4mm_P0.5mm_EP2.45x2.45mm_ThermalVias +WQFN, 24 Pin (http://www.ti.com/lit/ds/symlink/ts3a27518e.pdf#page=33), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +39 +25 +Package_DFN_QFN +WQFN-32-1EP_5x5mm_P0.5mm_EP3.1x3.1mm +QFN, 32-Leads, Body 5x5x0.8mm, Pitch 0.5mm, Thermal Pad 3.1x3.1mm; (see Texas Instruments LM25119 http://www.ti.com/lit/ds/symlink/lm25119.pdf) +WQFN 0.5 +0 +37 +33 +Package_DFN_QFN +WQFN-42-1EP_3.5x9mm_P0.5mm_EP2.05x7.55mm +WQFN, 42 Pin (http://www.ti.com/lit/ds/symlink/ts3l501e.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +57 +43 +Package_DFN_QFN +WQFN-42-1EP_3.5x9mm_P0.5mm_EP2.05x7.55mm_ThermalVias +WQFN, 42 Pin (http://www.ti.com/lit/ds/symlink/ts3l501e.pdf#page=23), generated with kicad-footprint-generator ipc_noLead_generator.py +WQFN NoLead +0 +82 +43 +Package_DIP +DIP-4_W7.62mm +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_LongPads +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_SMDSocket_SmallPads +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_Socket +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +4 +4 +Package_DIP +DIP-4_W7.62mm_Socket_LongPads +4-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +4 +4 +Package_DIP +DIP-4_W8.89mm_SMDSocket_LongPads +4-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +4 +4 +Package_DIP +DIP-4_W10.16mm +4-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +4 +4 +Package_DIP +DIP-4_W10.16mm_LongPads +4-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +4 +4 +Package_DIP +DIP-5-6_W7.62mm +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_LongPads +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_SMDSocket_SmallPads +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_Socket +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +5 +5 +Package_DIP +DIP-5-6_W7.62mm_Socket_LongPads +5-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +5 +5 +Package_DIP +DIP-5-6_W8.89mm_SMDSocket_LongPads +5-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +5 +5 +Package_DIP +DIP-5-6_W10.16mm +5-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +5 +5 +Package_DIP +DIP-5-6_W10.16mm_LongPads +5-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +5 +5 +Package_DIP +DIP-6_W7.62mm +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_LongPads +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_SMDSocket_SmallPads +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_Socket +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +6 +6 +Package_DIP +DIP-6_W7.62mm_Socket_LongPads +6-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +6 +6 +Package_DIP +DIP-6_W8.89mm_SMDSocket_LongPads +6-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +6 +6 +Package_DIP +DIP-6_W10.16mm +6-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +6 +6 +Package_DIP +DIP-6_W10.16mm_LongPads +6-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +6 +6 +Package_DIP +DIP-8-16_W7.62mm +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +DIP-8-16_W7.62mm_Socket +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +8 +8 +Package_DIP +DIP-8-16_W7.62mm_Socket_LongPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +8 +8 +Package_DIP +DIP-8-N6_W7.62mm +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), missing pin 6 +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +DIP-8-N7_W7.62mm +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), missing pin 7 +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +DIP-8_W7.62mm +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_LongPads +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_SMDSocket_SmallPads +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_Socket +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +8 +8 +Package_DIP +DIP-8_W7.62mm_Socket_LongPads +8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +8 +8 +Package_DIP +DIP-8_W8.89mm_SMDSocket_LongPads +8-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +8 +8 +Package_DIP +DIP-8_W10.16mm +8-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +8 +8 +Package_DIP +DIP-8_W10.16mm_LongPads +8-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +8 +8 +Package_DIP +DIP-10_W7.62mm +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_LongPads +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_SMDSocket_SmallPads +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_Socket +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +10 +10 +Package_DIP +DIP-10_W7.62mm_Socket_LongPads +10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +10 +10 +Package_DIP +DIP-10_W8.89mm_SMDSocket_LongPads +10-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +10 +10 +Package_DIP +DIP-10_W10.16mm +10-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +10 +10 +Package_DIP +DIP-10_W10.16mm_LongPads +10-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +10 +10 +Package_DIP +DIP-12_W7.62mm +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_LongPads +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_SMDSocket_SmallPads +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_Socket +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +12 +12 +Package_DIP +DIP-12_W7.62mm_Socket_LongPads +12-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +12 +12 +Package_DIP +DIP-12_W8.89mm_SMDSocket_LongPads +12-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +12 +12 +Package_DIP +DIP-12_W10.16mm +12-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +12 +12 +Package_DIP +DIP-12_W10.16mm_LongPads +12-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +12 +12 +Package_DIP +DIP-14_W7.62mm +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_LongPads +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_SMDSocket_SmallPads +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_Socket +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +14 +14 +Package_DIP +DIP-14_W7.62mm_Socket_LongPads +14-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +14 +14 +Package_DIP +DIP-14_W8.89mm_SMDSocket_LongPads +14-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +14 +14 +Package_DIP +DIP-14_W10.16mm +14-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +14 +14 +Package_DIP +DIP-14_W10.16mm_LongPads +14-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +14 +14 +Package_DIP +DIP-16_W7.62mm +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_LongPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_SMDSocket_SmallPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_Socket +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +16 +16 +Package_DIP +DIP-16_W7.62mm_Socket_LongPads +16-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +16 +16 +Package_DIP +DIP-16_W8.89mm_SMDSocket_LongPads +16-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +16 +16 +Package_DIP +DIP-16_W10.16mm +16-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +16 +16 +Package_DIP +DIP-16_W10.16mm_LongPads +16-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +16 +16 +Package_DIP +DIP-18_W7.62mm +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_LongPads +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_SMDSocket_SmallPads +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_Socket +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +18 +18 +Package_DIP +DIP-18_W7.62mm_Socket_LongPads +18-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +18 +18 +Package_DIP +DIP-18_W8.89mm_SMDSocket_LongPads +18-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +18 +18 +Package_DIP +DIP-20_W7.62mm +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_LongPads +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_SMDSocket_SmallPads +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_Socket +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +20 +20 +Package_DIP +DIP-20_W7.62mm_Socket_LongPads +20-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +20 +20 +Package_DIP +DIP-20_W8.89mm_SMDSocket_LongPads +20-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +20 +20 +Package_DIP +DIP-22_W7.62mm +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_LongPads +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_SMDSocket_SmallPads +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_Socket +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +22 +22 +Package_DIP +DIP-22_W7.62mm_Socket_LongPads +22-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +22 +22 +Package_DIP +DIP-22_W8.89mm_SMDSocket_LongPads +22-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +22 +22 +Package_DIP +DIP-22_W10.16mm +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_LongPads +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_SMDSocket_SmallPads +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil SMDSocket SmallPads +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_Socket +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket +0 +22 +22 +Package_DIP +DIP-22_W10.16mm_Socket_LongPads +22-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket LongPads +0 +22 +22 +Package_DIP +DIP-22_W11.43mm_SMDSocket_LongPads +22-lead though-hole mounted DIP package, row spacing 11.43 mm (450 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 11.43mm 450mil SMDSocket LongPads +0 +22 +22 +Package_DIP +DIP-24_W7.62mm +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_LongPads +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_SMDSocket_SmallPads +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_Socket +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +24 +24 +Package_DIP +DIP-24_W7.62mm_Socket_LongPads +24-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +24 +24 +Package_DIP +DIP-24_W8.89mm_SMDSocket_LongPads +24-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +24 +24 +Package_DIP +DIP-24_W10.16mm +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils) +THT DIP DIL PDIP 2.54mm 10.16mm 400mil +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_LongPads +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil LongPads +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_SMDSocket_SmallPads +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil SMDSocket SmallPads +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_Socket +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket +0 +24 +24 +Package_DIP +DIP-24_W10.16mm_Socket_LongPads +24-lead though-hole mounted DIP package, row spacing 10.16 mm (400 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 10.16mm 400mil Socket LongPads +0 +24 +24 +Package_DIP +DIP-24_W11.43mm_SMDSocket_LongPads +24-lead though-hole mounted DIP package, row spacing 11.43 mm (450 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 11.43mm 450mil SMDSocket LongPads +0 +24 +24 +Package_DIP +DIP-24_W15.24mm +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_LongPads +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_SMDSocket_SmallPads +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_Socket +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +24 +24 +Package_DIP +DIP-24_W15.24mm_Socket_LongPads +24-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +24 +24 +Package_DIP +DIP-24_W16.51mm_SMDSocket_LongPads +24-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +24 +24 +Package_DIP +DIP-28_W7.62mm +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils) +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_LongPads +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_SMDSocket_SmallPads +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil SMDSocket SmallPads +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_Socket +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket +0 +28 +28 +Package_DIP +DIP-28_W7.62mm_Socket_LongPads +28-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Socket LongPads +0 +28 +28 +Package_DIP +DIP-28_W8.89mm_SMDSocket_LongPads +28-lead though-hole mounted DIP package, row spacing 8.89 mm (350 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 8.89mm 350mil SMDSocket LongPads +0 +28 +28 +Package_DIP +DIP-28_W15.24mm +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_LongPads +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_SMDSocket_SmallPads +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_Socket +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +28 +28 +Package_DIP +DIP-28_W15.24mm_Socket_LongPads +28-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +28 +28 +Package_DIP +DIP-28_W16.51mm_SMDSocket_LongPads +28-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +28 +28 +Package_DIP +DIP-32_W7.62mm +32-lead dip package, row spacing 7.62 mm (300 mils) +DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +32 +32 +Package_DIP +DIP-32_W15.24mm +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_LongPads +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_SMDSocket_SmallPads +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_Socket +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +32 +32 +Package_DIP +DIP-32_W15.24mm_Socket_LongPads +32-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +32 +32 +Package_DIP +DIP-32_W16.51mm_SMDSocket_LongPads +32-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +32 +32 +Package_DIP +DIP-40_W15.24mm +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_LongPads +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_SMDSocket_SmallPads +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_Socket +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +40 +40 +Package_DIP +DIP-40_W15.24mm_Socket_LongPads +40-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +40 +40 +Package_DIP +DIP-40_W16.51mm_SMDSocket_LongPads +40-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +40 +40 +Package_DIP +DIP-40_W25.4mm +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils) +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_LongPads +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil LongPads +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_SMDSocket_SmallPads +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil SMDSocket SmallPads +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_Socket +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket +0 +40 +40 +Package_DIP +DIP-40_W25.4mm_Socket_LongPads +40-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket LongPads +0 +40 +40 +Package_DIP +DIP-40_W26.67mm_SMDSocket_LongPads +40-lead though-hole mounted DIP package, row spacing 26.67 mm (1050 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 26.669999999999998mm 1050mil SMDSocket LongPads +0 +40 +40 +Package_DIP +DIP-42_W15.24mm +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_LongPads +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_SMDSocket_SmallPads +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_Socket +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +42 +42 +Package_DIP +DIP-42_W15.24mm_Socket_LongPads +42-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +42 +42 +Package_DIP +DIP-42_W16.51mm_SMDSocket_LongPads +42-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +42 +42 +Package_DIP +DIP-48_W15.24mm +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_LongPads +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_SMDSocket_SmallPads +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_Socket +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +48 +48 +Package_DIP +DIP-48_W15.24mm_Socket_LongPads +48-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +48 +48 +Package_DIP +DIP-48_W16.51mm_SMDSocket_LongPads +48-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +48 +48 +Package_DIP +DIP-64_W15.24mm +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils) +THT DIP DIL PDIP 2.54mm 15.24mm 600mil +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_LongPads +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil LongPads +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_SMDSocket_SmallPads +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil SMDSocket SmallPads +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_Socket +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket +0 +64 +64 +Package_DIP +DIP-64_W15.24mm_Socket_LongPads +64-lead though-hole mounted DIP package, row spacing 15.24 mm (600 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 15.24mm 600mil Socket LongPads +0 +64 +64 +Package_DIP +DIP-64_W16.51mm_SMDSocket_LongPads +64-lead though-hole mounted DIP package, row spacing 16.51 mm (650 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 16.51mm 650mil SMDSocket LongPads +0 +64 +64 +Package_DIP +DIP-64_W22.86mm +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils) +THT DIP DIL PDIP 2.54mm 22.86mm 900mil +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_LongPads +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), LongPads +THT DIP DIL PDIP 2.54mm 22.86mm 900mil LongPads +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_SMDSocket_SmallPads +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 22.86mm 900mil SMDSocket SmallPads +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_Socket +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), Socket +THT DIP DIL PDIP 2.54mm 22.86mm 900mil Socket +0 +64 +64 +Package_DIP +DIP-64_W22.86mm_Socket_LongPads +64-lead though-hole mounted DIP package, row spacing 22.86 mm (900 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 22.86mm 900mil Socket LongPads +0 +64 +64 +Package_DIP +DIP-64_W24.13mm_SMDSocket_LongPads +64-lead though-hole mounted DIP package, row spacing 24.13 mm (950 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 24.13mm 950mil SMDSocket LongPads +0 +64 +64 +Package_DIP +DIP-64_W25.4mm +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils) +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_LongPads +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil LongPads +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_SMDSocket_SmallPads +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), SMDSocket, SmallPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil SMDSocket SmallPads +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_Socket +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket +0 +64 +64 +Package_DIP +DIP-64_W25.4mm_Socket_LongPads +64-lead though-hole mounted DIP package, row spacing 25.4 mm (1000 mils), Socket, LongPads +THT DIP DIL PDIP 2.54mm 25.4mm 1000mil Socket LongPads +0 +64 +64 +Package_DIP +DIP-64_W26.67mm_SMDSocket_LongPads +64-lead though-hole mounted DIP package, row spacing 26.67 mm (1050 mils), SMDSocket, LongPads +THT DIP DIL PDIP 2.54mm 26.669999999999998mm 1050mil SMDSocket LongPads +0 +64 +64 +Package_DIP +Fairchild_LSOP-8 +8-Lead, 300\" Wide, Surface Mount Package (https://www.fairchildsemi.com/package-drawings/ML/MLSOP08A.pdf) +LSOP 2.54mm 300mil +0 +8 +8 +Package_DIP +PowerIntegrations_PDIP-8B +Power Integrations variant of 8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads, see https://www.power.com/sites/default/files/product-docs/lnk520.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +7 +7 +Package_DIP +PowerIntegrations_PDIP-8C +Power Integrations variant of 8-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads, see https://ac-dc.power.com/sites/default/files/product-docs/tinyswitch-iii_family_datasheet.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +7 +7 +Package_DIP +PowerIntegrations_SDIP-10C +PowerIntegrations variant of 10-lead though-hole mounted DIP package, row spacing 7.62 mm (300 mils), LongPads, see https://www.power.com/sites/default/files/product-docs/tophx_family_datasheet.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil LongPads +0 +9 +9 +Package_DIP +PowerIntegrations_SMD-8 +PowerIntegrations variant of 8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils), see https://www.power.com/sites/default/files/product-docs/lnk520.pdf +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +PowerIntegrations_SMD-8B +PowerIntegrations variant of 8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils), see https://www.power.com/sites/default/files/product-docs/lnk520.pdf +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +PowerIntegrations_SMD-8C +PowerIntegrations variant of 8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils), see https://ac-dc.power.com/sites/default/files/product-docs/tinyswitch-iii_family_datasheet.pdf +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +7 +7 +Package_DIP +PowerIntegrations_eDIP-12B +Power Integrations eDIP-12B, see https://www.power.com/sites/default/files/product-docs/linkswitch-pl_family_datasheet.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil +0 +11 +11 +Package_DIP +SMDIP-4_W7.62mm +4-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +4 +4 +Package_DIP +SMDIP-4_W9.53mm +4-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +4 +4 +Package_DIP +SMDIP-4_W9.53mm_Clearance8mm +4-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +4 +4 +Package_DIP +SMDIP-4_W11.48mm +4-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +4 +4 +Package_DIP +SMDIP-6_W7.62mm +6-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +6 +6 +Package_DIP +SMDIP-6_W9.53mm +6-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +6 +6 +Package_DIP +SMDIP-6_W9.53mm_Clearance8mm +6-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +6 +6 +Package_DIP +SMDIP-6_W11.48mm +6-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +6 +6 +Package_DIP +SMDIP-8_W7.62mm +8-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +8 +8 +Package_DIP +SMDIP-8_W9.53mm +8-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +8 +8 +Package_DIP +SMDIP-8_W9.53mm_Clearance8mm +8-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +8 +8 +Package_DIP +SMDIP-8_W11.48mm +8-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +8 +8 +Package_DIP +SMDIP-10_W7.62mm +10-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +10 +10 +Package_DIP +SMDIP-10_W9.53mm +10-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +10 +10 +Package_DIP +SMDIP-10_W9.53mm_Clearance8mm +10-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +10 +10 +Package_DIP +SMDIP-10_W11.48mm +10-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +10 +10 +Package_DIP +SMDIP-12_W7.62mm +12-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +12 +12 +Package_DIP +SMDIP-12_W9.53mm +12-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +12 +12 +Package_DIP +SMDIP-12_W9.53mm_Clearance8mm +12-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +12 +12 +Package_DIP +SMDIP-12_W11.48mm +12-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +12 +12 +Package_DIP +SMDIP-14_W7.62mm +14-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +14 +14 +Package_DIP +SMDIP-14_W9.53mm +14-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +14 +14 +Package_DIP +SMDIP-14_W9.53mm_Clearance8mm +14-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +14 +14 +Package_DIP +SMDIP-14_W11.48mm +14-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +14 +14 +Package_DIP +SMDIP-16_W7.62mm +16-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +16 +16 +Package_DIP +SMDIP-16_W9.53mm +16-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +16 +16 +Package_DIP +SMDIP-16_W9.53mm_Clearance8mm +16-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +16 +16 +Package_DIP +SMDIP-16_W11.48mm +16-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +16 +16 +Package_DIP +SMDIP-18_W7.62mm +18-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +18 +18 +Package_DIP +SMDIP-18_W9.53mm +18-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +18 +18 +Package_DIP +SMDIP-18_W9.53mm_Clearance8mm +18-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +18 +18 +Package_DIP +SMDIP-18_W11.48mm +18-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +18 +18 +Package_DIP +SMDIP-20_W7.62mm +20-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +20 +20 +Package_DIP +SMDIP-20_W9.53mm +20-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +20 +20 +Package_DIP +SMDIP-20_W9.53mm_Clearance8mm +20-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +20 +20 +Package_DIP +SMDIP-20_W11.48mm +20-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +20 +20 +Package_DIP +SMDIP-22_W7.62mm +22-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +22 +22 +Package_DIP +SMDIP-22_W9.53mm +22-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +22 +22 +Package_DIP +SMDIP-22_W9.53mm_Clearance8mm +22-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils), Clearance8mm +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil Clearance8mm +0 +22 +22 +Package_DIP +SMDIP-22_W11.48mm +22-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +22 +22 +Package_DIP +SMDIP-24_W7.62mm +24-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +24 +24 +Package_DIP +SMDIP-24_W9.53mm +24-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +24 +24 +Package_DIP +SMDIP-24_W11.48mm +24-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +24 +24 +Package_DIP +SMDIP-24_W15.24mm +24-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +24 +24 +Package_DIP +SMDIP-28_W15.24mm +28-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +28 +28 +Package_DIP +SMDIP-32_W7.62mm +32-lead surface-mounted (SMD) DIP package, row spacing 7.62 mm (300 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 7.62mm 300mil +0 +32 +32 +Package_DIP +SMDIP-32_W9.53mm +32-lead surface-mounted (SMD) DIP package, row spacing 9.53 mm (375 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 9.53mm 375mil +0 +32 +32 +Package_DIP +SMDIP-32_W11.48mm +32-lead surface-mounted (SMD) DIP package, row spacing 11.48 mm (451 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 11.48mm 451mil +0 +32 +32 +Package_DIP +SMDIP-32_W15.24mm +32-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +32 +32 +Package_DIP +SMDIP-40_W15.24mm +40-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +40 +40 +Package_DIP +SMDIP-40_W25.24mm +40-lead surface-mounted (SMD) DIP package, row spacing 25.24 mm (993 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 25.24mm 993mil +0 +40 +40 +Package_DIP +SMDIP-42_W15.24mm +42-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +42 +42 +Package_DIP +SMDIP-48_W15.24mm +48-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +48 +48 +Package_DIP +SMDIP-64_W15.24mm +64-lead surface-mounted (SMD) DIP package, row spacing 15.24 mm (600 mils) +SMD DIP DIL PDIP SMDIP 2.54mm 15.24mm 600mil +0 +64 +64 +Package_DIP +Toshiba_11-7A9 +Toshiba 11-7A9 package, like 6-lead dip package with missing pin 5, row spacing 7.62 mm (300 mils), https://toshiba.semicon-storage.com/info/docget.jsp?did=1421&prodName=TLP3021(S) +Toshiba 11-7A9 DIL DIP PDIP 2.54mm 7.62mm 300mil +0 +5 +5 +Package_DIP +Vishay_HVM-DIP-3_W7.62mm +3-lead though-hole mounted high-volatge DIP package (based on standard DIP-4), row spacing 7.62 mm (300 mils), see https://www.vishay.com/docs/91361/hexdip.pdf +THT DIP DIL PDIP 2.54mm 7.62mm 300mil Vishay HVMDIP HEXDIP +0 +4 +3 +Package_DirectFET +DirectFET_L4 +DirectFET L4 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=41 +DirectFET L4 MOSFET Infineon +0 +11 +3 +Package_DirectFET +DirectFET_L6 +DirectFET L6 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=42 +DirectFET L6 MOSFET Infineon +0 +13 +3 +Package_DirectFET +DirectFET_L8 +DirectFET L8 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=43 +DirectFET L8 MOSFET Infineon +0 +15 +3 +Package_DirectFET +DirectFET_LA +DirectFET LA https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=44 +DirectFET LA MOSFET Infineon +0 +15 +3 +Package_DirectFET +DirectFET_M2 +DirectFET M2 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=33 +DirectFET M2 MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_M4 +DirectFET M4 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=34 +DirectFET M4 MOSFET Infineon +0 +9 +3 +Package_DirectFET +DirectFET_MA +DirectFET MA https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=35 +DirectFET MA MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_MB +DirectFET MB https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=36 +DirectFET MB MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_MC +DirectFET MC https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=37 +DirectFET MC MOSFET Infineon +0 +10 +3 +Package_DirectFET +DirectFET_MD +DirectFET MD https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=38 +DirectFET MD MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_ME +DirectFET ME https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=39 +DirectFET ME MOSFET Infineon +0 +10 +3 +Package_DirectFET +DirectFET_MF +DirectFET MF https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=40 +DirectFET MF MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_MN +DirectFET MN https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=30 +DirectFET MN MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MP +DirectFET MP https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=28 +DirectFET MP MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MQ +DirectFET MQ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=29 +DirectFET MQ MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MT +DirectFET MT https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=26 +DirectFET MT MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MU +DirectFET MU https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=32 +DirectFET MU MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MX +DirectFET MX https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=27 +DirectFET MX MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_MZ +DirectFET MZ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=31 +DirectFET MZ MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_S1 +DirectFET S1 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=20 +DirectFET S1 MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_S2 +DirectFET S2 https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=21 +DirectFET S2 MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_S3C +DirectFET S3C https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=25 +DirectFET S3C MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_SA +DirectFET SA https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=22 +DirectFET SA MOSFET Infineon +0 +8 +3 +Package_DirectFET +DirectFET_SB +DirectFET SB https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=23 +DirectFET SB MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_SC +DirectFET SC https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=24 +DirectFET SC MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_SH +DirectFET SH https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=19 +DirectFET SH MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_SJ +DirectFET SJ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=18 +DirectFET SJ MOSFET Infineon +0 +7 +3 +Package_DirectFET +DirectFET_SQ +DirectFET SQ https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=17 +DirectFET SQ MOSFET Infineon +0 +6 +3 +Package_DirectFET +DirectFET_ST +DirectFET ST https://www.infineon.com/dgdl/Infineon-AN-1035-ApplicationNotes-v29_01-EN.pdf?fileId=5546d462533600a40153559159020f76#page=16 +DirectFET ST MOSFET Infineon +0 +7 +3 +Package_LCC +PLCC-20 +PLCC, 20 pins, surface mount +plcc smt +0 +20 +20 +Package_LCC +PLCC-20_SMD-Socket +PLCC, 20 pins, surface mount +plcc smt +0 +20 +20 +Package_LCC +PLCC-20_THT-Socket +PLCC, 20 pins, through hole +plcc leaded +0 +20 +20 +Package_LCC +PLCC-28 +PLCC, 28 pins, surface mount +plcc smt +0 +28 +28 +Package_LCC +PLCC-28_SMD-Socket +PLCC, 28 pins, surface mount +plcc smt +0 +28 +28 +Package_LCC +PLCC-28_THT-Socket +PLCC, 28 pins, through hole +plcc leaded +0 +28 +28 +Package_LCC +PLCC-32_11.4x14.0mm_P1.27mm +PLCC, 32 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/doc0015.pdf), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +32 +32 +Package_LCC +PLCC-32_THT-Socket +PLCC, 32 pins, through hole, http://www.assmann-wsw.com/fileadmin/datasheets/ASS_0981_CO.pdf +plcc leaded +0 +32 +32 +Package_LCC +PLCC-44 +PLCC, 44 pins, surface mount +plcc smt +0 +44 +44 +Package_LCC +PLCC-44_16.6x16.6mm_P1.27mm +PLCC, 44 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +44 +44 +Package_LCC +PLCC-44_SMD-Socket +PLCC, 44 pins, surface mount +plcc smt +0 +44 +44 +Package_LCC +PLCC-44_THT-Socket +PLCC, 44 pins, through hole +plcc leaded +0 +44 +44 +Package_LCC +PLCC-52 +PLCC, 52 pins, surface mount +plcc smt +0 +52 +52 +Package_LCC +PLCC-52_SMD-Socket +PLCC, 52 pins, surface mount +plcc smt +0 +52 +52 +Package_LCC +PLCC-52_THT-Socket +PLCC, 52 pins, through hole +plcc leaded +0 +52 +52 +Package_LCC +PLCC-68 +PLCC, 68 pins, surface mount +plcc smt +0 +68 +68 +Package_LCC +PLCC-68_24.2x24.2mm_P1.27mm +PLCC, 68 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +68 +68 +Package_LCC +PLCC-68_SMD-Socket +PLCC, 68 pins, surface mount +plcc smt +0 +68 +68 +Package_LCC +PLCC-68_THT-Socket +PLCC, 68 pins, through hole +plcc leaded +0 +68 +68 +Package_LCC +PLCC-84 +PLCC, 84 pins, surface mount +plcc smt +0 +84 +84 +Package_LCC +PLCC-84_29.3x29.3mm_P1.27mm +PLCC, 84 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_plcc_jLead_generator.py +PLCC LCC +0 +84 +84 +Package_LCC +PLCC-84_SMD-Socket +PLCC, 84 pins, surface mount +plcc smt +0 +84 +84 +Package_LCC +PLCC-84_THT-Socket +PLCC, 84 pins, through hole +plcc leaded +0 +84 +84 +Package_LGA +AMS_LGA-10-1EP_2.7x4mm_P0.6mm +LGA-10, http://ams.com/eng/content/download/951091/2269479/471718 +lga land grid array +0 +13 +11 +Package_LGA +AMS_LGA-20_4.7x4.5mm_P0.65mm +http://ams.com/eng/content/download/1008631/2361759/498838 +AMS LGA +0 +20 +20 +Package_LGA +Bosch_LGA-8_2.5x2.5mm_P0.65mm_ClockwisePinNumbering +LGA-8 +lga land grid array +0 +8 +8 +Package_LGA +Bosch_LGA-8_2x2.5mm_P0.65mm_ClockwisePinNumbering +LGA-8, https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMP280-DS001-18.pdf +lga land grid array +0 +8 +8 +Package_LGA +Bosch_LGA-8_3x3mm_P0.8mm_ClockwisePinNumbering +Bosch LGA, 8 Pin (https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BME680-DS001-00.pdf#page=44), generated with kicad-footprint-generator ipc_noLead_generator.py +Bosch LGA NoLead +0 +8 +8 +Package_LGA +Bosch_LGA-14_3x2.5mm_P0.5mm +LGA-14 Bosch https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BMI160-DS000-07.pdf +lga land grid array +0 +14 +14 +Package_LGA +LGA-8_3x5mm_P1.25mm +LGA-8 +lga land grid array +0 +8 +8 +Package_LGA +LGA-12_2x2mm_P0.5mm +LGA12 +lga land grid array +0 +12 +12 +Package_LGA +LGA-14_2x2mm_P0.35mm_LayoutBorder3x4y +LGA, 14 Pin (http://www.st.com/resource/en/datasheet/lis2dh.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +14 +14 +Package_LGA +LGA-14_3x2.5mm_P0.5mm_LayoutBorder3x4y +LGA, 14 Pin (http://www.st.com/resource/en/datasheet/lsm6ds3.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +14 +14 +Package_LGA +LGA-14_3x5mm_P0.8mm_LayoutBorder1x6y +LGA, 14 Pin (http://www.st.com/resource/en/datasheet/lsm303dlhc.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +14 +14 +Package_LGA +LGA-16_3x3mm_P0.5mm +http://www.memsic.com/userfiles/files/DataSheets/Magnetic-Sensors-Datasheets/MMC5883MA-RevC.pdf +lga land grid array +0 +16 +16 +Package_LGA +LGA-16_3x3mm_P0.5mm_LayoutBorder3x5y +LGA, 16 Pin (http://www.st.com/resource/en/datasheet/lis331hh.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +16 +16 +Package_LGA +LGA-16_4x4mm_P0.65mm_LayoutBorder4x4y +LGA, 16 Pin (http://www.st.com/resource/en/datasheet/l3gd20.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +LGA NoLead +0 +16 +16 +Package_LGA +LGA-24L_3x3.5mm_P0.43mm +LGA 24L 3x3.5mm Pitch 0.43mm +LGA 24L 3x3.5mm Pitch 0.43mm +0 +24 +24 +Package_LGA +LGA-28_5.2x3.8mm_P0.5mm +LGA 28 5.2x3.8mm Pitch 0.5mm +LGA 28 5.2x3.8mm Pitch 0.5mm +0 +28 +28 +Package_LGA +Linear_LGA-133_15.0x15.0mm_Layout12x12_P1.27mm +Analog Devices (Linear Tech), 133-pin LGA uModule, 15.0x15.0x4.32mm, https://www.analog.com/media/en/technical-documentation/data-sheets/4637fc.pdf +133 pin lga +0 +133 +133 +Package_LGA +NXP_LGA-8_3x5mm_P1.25mm_H1.1mm +NXP LGA, 8 Pin (https://www.nxp.com/docs/en/data-sheet/MPL3115A2.pdf#page=42), generated with kicad-footprint-generator ipc_noLead_generator.py +NXP LGA NoLead +0 +8 +8 +Package_LGA +NXP_LGA-8_3x5mm_P1.25mm_H1.2mm +NXP LGA, 8 Pin (https://www.nxp.com/docs/en/data-sheet/MPL115A1.pdf#page=15), generated with kicad-footprint-generator ipc_noLead_generator.py +NXP LGA NoLead +0 +8 +8 +Package_LGA +ST_HLGA-10_2.5x2.5mm_P0.6mm_LayoutBorder3x2y +ST HLGA, 10 Pin (https://www.st.com/resource/en/datasheet/lps25hb.pdf#page=46), generated with kicad-footprint-generator ipc_noLead_generator.py +ST HLGA NoLead +0 +10 +10 +Package_LGA +Texas_SIL0008D_MicroSiP-8-1EP_2.8x3mm_P0.65mm_EP1.1x1.9mm +Texas SIL0008D MicroSiP, 8 Pin (http://www.ti.com/lit/ds/symlink/tps82130.pdf#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +12 +9 +Package_LGA +Texas_SIL0008D_MicroSiP-8-1EP_2.8x3mm_P0.65mm_EP1.1x1.9mm_ThermalVias +Texas SIL0008D MicroSiP, 8 Pin (http://www.ti.com/lit/ds/symlink/tps82130.pdf#page=19), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +16 +9 +Package_LGA +Texas_SIL0010A_MicroSiP-10-1EP_3.8x3mm_P0.6mm_EP0.7x2.9mm +Texas SIL0010A MicroSiP, 10 Pin (http://www.ti.com/lit/ml/mpds579b/mpds579b.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +14 +11 +Package_LGA +Texas_SIL0010A_MicroSiP-10-1EP_3.8x3mm_P0.6mm_EP0.7x2.9mm_ThermalVias +Texas SIL0010A MicroSiP, 10 Pin (http://www.ti.com/lit/ml/mpds579b/mpds579b.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +Texas MicroSiP NoLead +0 +18 +11 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP4x4mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00482-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +154 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP4x4mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00482-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +171 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP5x5mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00476-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +161 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP5x5mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00476-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +187 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP6.61x5.615mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00485-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +165 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP6.61x5.615mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00485-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +196 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP7.2x6.35mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00487-01.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +175 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP7.2x6.35mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00487-01.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +218 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP8.93x8.7mm +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00479-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +194 +145 +Package_QFP +EQFP-144-1EP_20x20mm_P0.5mm_EP8.93x8.7mm_ThermalVias +EQFP, 144 Pin (https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/packaging/04r00479-02.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +EQFP QFP +0 +259 +145 +Package_QFP +HTQFP-64-1EP_10x10mm_P0.5mm_EP8x8mm +64-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1 mm Body, 2.00 mm Footprint [HTQFP] thermal pad +HTQFP-64 Pitch 0.5 +0 +69 +65 +Package_QFP +HTQFP-64-1EP_10x10mm_P0.5mm_EP8x8mm_Mask4.4x4.4mm_ThermalVias +64-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1 mm Body, 2.00 mm Footprint [HTQFP] thermal pad +HTQFP-64 Pitch 0.5 +0 +135 +65 +Package_QFP +LQFP-32_5x5mm_P0.5mm +LQFP, 32 Pin (https://www.nxp.com/docs/en/package-information/SOT401-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +32 +32 +Package_QFP +LQFP-32_7x7mm_P0.8mm +LQFP, 32 Pin (https://www.nxp.com/docs/en/package-information/SOT358-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +32 +32 +Package_QFP +LQFP-36_7x7mm_P0.65mm +LQFP, 36 Pin (https://www.onsemi.com/pub/Collateral/561AV.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +36 +36 +Package_QFP +LQFP-44_10x10mm_P0.8mm +LQFP, 44 Pin (https://www.nxp.com/files-static/shared/doc/package_info/98ASS23225W.pdf?&fsrch=1), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +44 +44 +Package_QFP +LQFP-48-1EP_7x7mm_P0.5mm_EP3.6x3.6mm +LQFP, 48 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +58 +49 +Package_QFP +LQFP-48-1EP_7x7mm_P0.5mm_EP3.6x3.6mm_ThermalVias +LQFP, 48 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +75 +49 +Package_QFP +LQFP-48_7x7mm_P0.5mm +LQFP, 48 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ltc2358-16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +48 +48 +Package_QFP +LQFP-52-1EP_10x10mm_P0.65mm_EP4.8x4.8mm +LQFP, 52 Pin (https://www.onsemi.com/pub/Collateral/848H-01.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +62 +53 +Package_QFP +LQFP-52-1EP_10x10mm_P0.65mm_EP4.8x4.8mm_ThermalVias +LQFP, 52 Pin (https://www.onsemi.com/pub/Collateral/848H-01.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +95 +53 +Package_QFP +LQFP-52_10x10mm_P0.65mm +LQFP, 52 Pin (https://www.nxp.com/docs/en/package-information/98ARL10526D.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +52 +52 +Package_QFP +LQFP-52_14x14mm_P1mm +LQFP, 52 Pin (http://www.holtek.com/documents/10179/116711/HT1632Cv170.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +52 +52 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP5x5mm +LQFP, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/adv7611.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +90 +65 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP5x5mm_ThermalVias +LQFP, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/adv7611.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +107 +65 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP6.5x6.5mm +LQFP, 64 Pin (https://www.nxp.com/files-static/shared/doc/package_info/98ARH98426A.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +90 +65 +Package_QFP +LQFP-64-1EP_10x10mm_P0.5mm_EP6.5x6.5mm_ThermalVias +LQFP, 64 Pin (https://www.nxp.com/files-static/shared/doc/package_info/98ARH98426A.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +127 +65 +Package_QFP +LQFP-64_7x7mm_P0.4mm +LQFP, 64 Pin (https://www.nxp.com/docs/en/package-information/SOT414-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +64 +64 +Package_QFP +LQFP-64_10x10mm_P0.5mm +LQFP, 64 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ad7606_7606-6_7606-4.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +64 +64 +Package_QFP +LQFP-64_14x14mm_P0.8mm +LQFP, 64 Pin (https://www.nxp.com/docs/en/package-information/SOT791-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +64 +64 +Package_QFP +LQFP-80_10x10mm_P0.4mm +LQFP, 80 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/q80.10x10.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +80 +80 +Package_QFP +LQFP-80_12x12mm_P0.5mm +LQFP, 80 Pin (https://www.nxp.com/docs/en/package-information/SOT315-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +80 +80 +Package_QFP +LQFP-80_14x14mm_P0.65mm +LQFP, 80 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/AD9852.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +80 +80 +Package_QFP +LQFP-100_14x14mm_P0.5mm +LQFP, 100 Pin (https://www.nxp.com/docs/en/package-information/SOT407-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +100 +100 +Package_QFP +LQFP-128_14x14mm_P0.4mm +LQFP, 128 Pin (https://www.renesas.com/eu/en/package-image/pdf/outdrawing/q128.14x14.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +128 +128 +Package_QFP +LQFP-128_14x20mm_P0.5mm +LQFP, 128 Pin (https://www.nxp.com/docs/en/package-information/SOT425-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +128 +128 +Package_QFP +LQFP-144_20x20mm_P0.5mm +LQFP, 144 Pin (http://ww1.microchip.com/downloads/en/PackagingSpec/00000049BQ.pdf#page=425), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +144 +144 +Package_QFP +LQFP-160_24x24mm_P0.5mm +LQFP, 160 Pin (https://www.nxp.com/docs/en/package-information/SOT435-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +160 +160 +Package_QFP +LQFP-176_20x20mm_P0.4mm +LQFP, 176 Pin (https://www.onsemi.com/pub/Collateral/566DB.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +176 +176 +Package_QFP +LQFP-176_24x24mm_P0.5mm +LQFP, 176 Pin (https://www.st.com/resource/en/datasheet/stm32f207vg.pdf#page=163), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +176 +176 +Package_QFP +LQFP-208_28x28mm_P0.5mm +LQFP, 208 Pin (https://www.nxp.com/docs/en/package-information/SOT459-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +208 +208 +Package_QFP +LQFP-216_24x24mm_P0.4mm +LQFP, 216 Pin (https://www.onsemi.com/pub/Collateral/561BE.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +LQFP QFP +0 +216 +216 +Package_QFP +MQFP-44_10x10mm_P0.8mm +MQFP, 44 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ad7722.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MQFP QFP +0 +44 +44 +Package_QFP +PQFP-44_10x10mm_P0.8mm +44-Lead Plastic Quad Flatpack - 10x10x2.5mm Body (http://www.onsemi.com/pub/Collateral/122BK.PDF) +PQFP 0.8 +0 +44 +44 +Package_QFP +PQFP-80_14x20mm_P0.8mm +PQFP80 14x20 / QIP80E CASE 122BS (see ON Semiconductor 122BS.PDF) +QFP 0.8 +0 +80 +80 +Package_QFP +PQFP-100_14x20mm_P0.65mm +PQFP, 100 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +100 +100 +Package_QFP +PQFP-112_20x20mm_P0.65mm +PQFP, 112 pins, 20mm sq body, 0.65mm pitch (http://cache.freescale.com/files/shared/doc/package_info/98ASS23330W.pdf, http://www.nxp.com/docs/en/application-note/AN4388.pdf) +PQFP 112 +0 +112 +112 +Package_QFP +PQFP-132_24x24mm_P0.635mm +PQFP, 132 pins, 24mm sq body, 0.635mm pitch (https://www.intel.com/content/dam/www/public/us/en/documents/packaging-databooks/packaging-chapter-02-databook.pdf, http://www.nxp.com/docs/en/application-note/AN4388.pdf) +PQFP 132 +0 +132 +132 +Package_QFP +PQFP-132_24x24mm_P0.635mm_i386 +PQFP, 132 pins, 24mm sq body, 0.635mm pitch, Intel 386EX (https://www.intel.com/content/dam/www/public/us/en/documents/packaging-databooks/packaging-chapter-02-databook.pdf, http://www.nxp.com/docs/en/application-note/AN4388.pdf) +PQFP 132 Intel 386EX +0 +132 +132 +Package_QFP +PQFP-144_28x28mm_P0.65mm +PQFP, 144 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +144 +144 +Package_QFP +PQFP-160_28x28mm_P0.65mm +PQFP, 160 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +160 +160 +Package_QFP +PQFP-208_28x28mm_P0.5mm +PQFP, 208 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +208 +208 +Package_QFP +PQFP-240_32.1x32.1mm_P0.5mm +PQFP, 240 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +PQFP QFP +0 +240 +240 +Package_QFP +PQFP-256_28x28mm_P0.4mm +PQFP256 28x28 / QFP256J CASE 122BX (see ON Semiconductor 122BX.PDF) +QFP 0.4 +0 +256 +256 +Package_QFP +TQFP-32_7x7mm_P0.8mm +32-Lead Plastic Thin Quad Flatpack (PT) - 7x7x1.0 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +32 +32 +Package_QFP +TQFP-44-1EP_10x10mm_P0.8mm_EP4.5x4.5mm +44-Lead Plastic Thin Quad Flatpack (MW) - 10x10x1.0 mm Body [TQFP] With 4.5x4.5 mm Exposed Pad (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +54 +45 +Package_QFP +TQFP-44_10x10mm_P0.8mm +44-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1.0 mm Body [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +44 +44 +Package_QFP +TQFP-48-1EP_7x7mm_P0.5mm_EP3.5x3.5mm +48-Lead Thin Quad Flatpack (PT) - 7x7x1.0 mm Body [TQFP] With Exposed Pad (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.5 +0 +53 +49 +Package_QFP +TQFP-48-1EP_7x7mm_P0.5mm_EP5x5mm +TQFP, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf (page 45)), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +65 +49 +Package_QFP +TQFP-48-1EP_7x7mm_P0.5mm_EP5x5mm_ThermalVias +TQFP, 48 Pin (https://www.trinamic.com/fileadmin/assets/Products/ICs_Documents/TMC2100_datasheet_Rev1.08.pdf (page 45)), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +91 +49 +Package_QFP +TQFP-48_7x7mm_P0.5mm +48 LEAD TQFP 7x7mm (see MICREL TQFP7x7-48LD-PL-1.pdf) +QFP 0.5 +0 +48 +48 +Package_QFP +TQFP-52-1EP_10x10mm_P0.65mm_EP6.5x6.5mm +TQFP, 52 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_52_1.pdf), generated with kicad-footprint-generator ipc_qfp_generator.py +TQFP QFP +0 +78 +53 +Package_QFP +TQFP-52-1EP_10x10mm_P0.65mm_EP6.5x6.5mm_ThermalVias +TQFP, 52 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_52_1.pdf), generated with kicad-footprint-generator ipc_qfp_generator.py +TQFP QFP +0 +79 +53 +Package_QFP +TQFP-64-1EP_10x10mm_P0.5mm_EP8x8mm +64-Lead Plastic Thin Quad Flatpack (PT) - 10x10x1 mm Body, 2.00 mm Footprint [TQFP] thermal pad +QFP 0.5 +0 +90 +65 +Package_QFP +TQFP-64_7x7mm_P0.4mm +TQFP64 7x7, 0.4P CASE 932BH (see ON Semiconductor 932BH.PDF) +QFP 0.4 +0 +64 +64 +Package_QFP +TQFP-64_10x10mm_P0.5mm +TQFP, 64 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +64 +64 +Package_QFP +TQFP-64_14x14mm_P0.8mm +64-Lead Plastic Thin Quad Flatpack (PF) - 14x14x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.8 +0 +64 +64 +Package_QFP +TQFP-80-1EP_14x14mm_P0.65mm_EP9.5x9.5mm +80-Lead Plastic Thin Quad Flatpack (PF) - 14x14mm body, 9.5mm sq thermal pad (http://www.analog.com/media/en/technical-documentation/data-sheets/AD9852.pdf) +QFP 0.65 +0 +85 +81 +Package_QFP +TQFP-80_12x12mm_P0.5mm +80-Lead Plastic Thin Quad Flatpack (PT) - 12x12x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.5 +0 +80 +80 +Package_QFP +TQFP-80_14x14mm_P0.65mm +80-Lead Plastic Thin Quad Flatpack (PF) - 14x14x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.65 +0 +80 +80 +Package_QFP +TQFP-100-1EP_14x14mm_P0.5mm_EP5x5mm +TQFP, 100 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_100_4.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +117 +101 +Package_QFP +TQFP-100-1EP_14x14mm_P0.5mm_EP5x5mm_ThermalVias +TQFP, 100 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/tqfp_edsv/sv_100_4.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +143 +101 +Package_QFP +TQFP-100_12x12mm_P0.4mm +100-Lead Plastic Thin Quad Flatpack (PT) - 12x12x1 mm Body, 2.00 mm [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.4 +0 +100 +100 +Package_QFP +TQFP-100_14x14mm_P0.5mm +TQFP, 100 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +100 +100 +Package_QFP +TQFP-120_14x14mm_P0.4mm +TQFP120 14x14 / TQFP120 CASE 932AZ (see ON Semiconductor 932AZ.PDF) +QFP 0.4 +0 +120 +120 +Package_QFP +TQFP-128_14x14mm_P0.4mm +TQFP128 14x14 / TQFP128 CASE 932BB (see ON Semiconductor 932BB.PDF) +QFP 0.4 +0 +128 +128 +Package_QFP +TQFP-144_16x16mm_P0.4mm +144-Lead Plastic Thin Quad Flatpack (PH) - 16x16x1 mm Body, 2.00 mm Footprint [TQFP] (see Microchip Packaging Specification 00000049BS.pdf) +QFP 0.4 +0 +144 +144 +Package_QFP +TQFP-144_20x20mm_P0.5mm +TQFP, 144 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +144 +144 +Package_QFP +TQFP-176_24x24mm_P0.5mm +TQFP, 176 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +TQFP QFP +0 +176 +176 +Package_QFP +VQFP-80_14x14mm_P0.65mm +VQFP, 80 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +80 +80 +Package_QFP +VQFP-100_14x14mm_P0.5mm +VQFP, 100 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +100 +100 +Package_QFP +VQFP-128_14x14mm_P0.4mm +VQFP, 128 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +128 +128 +Package_QFP +VQFP-176_20x20mm_P0.4mm +VQFP, 176 Pin (http://www.microsemi.com/index.php?option=com_docman&task=doc_download&gid=131095), generated with kicad-footprint-generator ipc_gullwing_generator.py +VQFP QFP +0 +176 +176 +Package_SIP +PowerIntegrations_eSIP-7C +eSIP-7C Vertical Flat Package with Heatsink Tab, https://ac-dc.power.com/sites/default/files/product-docs/topswitch-jx_family_datasheet.pdf +Power Integrations E Package +0 +6 +6 +Package_SIP +PowerIntegrations_eSIP-7F +eSIP-7F Flat Package with Heatsink Tab https://ac-dc.power.com/sites/default/files/product-docs/linkswitch-ph_family_datasheet.pdf +Power Integrations L Package +0 +6 +6 +Package_SIP +SIP-8_19x3mm_P2.54mm +SIP 8-pin (http://www.njr.com/semicon/PDF/package/SIP8_E.pdf) +SIP8 +0 +8 +8 +Package_SIP +SIP-9_21.54x3mm_P2.54mm +SIP 9-pin () +SIP8 +0 +9 +9 +Package_SIP +SIP-9_22.3x3mm_P2.54mm +SIP 9-pin () +SIP8 +0 +9 +9 +Package_SIP +SIP3_11.6x8.5mm +RECOM,R78EXX,https://www.recom-power.com/pdf/Innoline/R-78Exx-0.5.pdf +SIP3 Regulator Module +0 +3 +3 +Package_SIP +SIP4_Sharp-SSR_P7.62mm_Angled +SIP4 Footprint for SSR made by Sharp +Solid State relais SSR Sharp +0 +4 +4 +Package_SIP +SIP4_Sharp-SSR_P7.62mm_Angled_NoHole +SIP4 Footprint for SSR made by Sharp +Solid State relais SSR Sharp +0 +4 +4 +Package_SIP +SIP4_Sharp-SSR_P7.62mm_Straight +SIP4 Footprint for SSR made by Sharp +Solid State relais SSR Sharp +0 +4 +4 +Package_SIP +SIP9_Housing +SIP9 +SIP9 +0 +9 +9 +Package_SIP +SIP9_Housing_BigPads +SIP9, large pads +SIP9 +0 +9 +9 +Package_SIP +SLA704XM +SIP SLA704XM (http://www.sumzi.com/upload/files/2007/07/2007073114282034189.PDF) +SIP +0 +18 +18 +Package_SIP +STK672-040-E +SIP-22 (http://www.onsemi.com/pub_link/Collateral/EN5227-D.PDF) +SIP-22 +0 +22 +22 +Package_SIP +STK672-080-E +SIP-15 (http://www.onsemi.com/pub_link/Collateral/EN6507-D.PDF) +SIP-15 +0 +15 +15 +Package_SIP +Sanyo_STK4xx-15_59.2x8.0mm_P2.54mm +Sanyo SIP-15, 59.2mm x 8.0mm bosy size, STK-433E STK-435E STK-436E (http://datasheet.octopart.com/STK430-Sanyo-datasheet-107060.pdf) +Sanyo SIP-15 +0 +15 +15 +Package_SIP +Sanyo_STK4xx-15_78.0x8.0mm_P2.54mm +Sanyo SIP-15, 78.0mm x 8.0mm bosy size, STK-437E STK-439E STK-441E STK-443E (http://datasheet.octopart.com/STK430-Sanyo-datasheet-107060.pdf) +Sanyo SIP-15 +0 +15 +15 +Package_SO +Diodes_PSOP-8 +8-Lead Plastic PSOP, Exposed Die Pad (see https://www.diodes.com/assets/Datasheets/AP2204.pdf) +SSOP 0.50 exposed pad +0 +12 +9 +Package_SO +Diodes_SO-8EP +8-Lead Plastic SO, Exposed Die Pad (see https://www.diodes.com/assets/Package-Files/SO-8EP.pdf) +SO exposed pad +0 +9 +9 +Package_SO +ETSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3x4.2mm +20-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body with Exposed Pad [eTSSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.65 +0 +27 +21 +Package_SO +HSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.1mm +HSOP, 8 Pin (https://www.st.com/resource/en/datasheet/l5973d.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOP SO +0 +13 +9 +Package_SO +HSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.1mm_ThermalVias +HSOP, 8 Pin (https://www.st.com/resource/en/datasheet/l5973d.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOP SO +0 +20 +9 +Package_SO +HSOP-20-1EP_11.0x15.9mm_P1.27mm_SlugDown +HSOP 11.0x15.9mm Pitch 1.27mm Slug Down (PowerSO-20) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/tda7266d.pdf, www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 1.27mm +0 +23 +21 +Package_SO +HSOP-20-1EP_11.0x15.9mm_P1.27mm_SlugDown_ThermalVias +HSOP 11.0x15.9mm Pitch 1.27mm Slug Down Thermal Vias (PowerSO-20) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/tda7266d.pdf, www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 1.27mm +0 +45 +21 +Package_SO +HSOP-20-1EP_11.0x15.9mm_P1.27mm_SlugUp +HSOP 11.0x15.9mm Pitch 1.27mm Slug Up (PowerSO-20) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/tda7266d.pdf, www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 1.27mm +0 +20 +20 +Package_SO +HSOP-36-1EP_11.0x15.9mm_P0.65mm_SlugDown +HSOP 11.0x15.9mm Pitch 0.65mm Slug Down (PowerSO-36) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/vn808cm-32-e.pdf, http://www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 0.65mm +0 +39 +37 +Package_SO +HSOP-36-1EP_11.0x15.9mm_P0.65mm_SlugDown_ThermalVias +HSOP 11.0x15.9mm Pitch 0.65mm Slug Down Thermal Vias (PowerSO-36) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/vn808cm-32-e.pdf, http://www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 0.65mm +0 +61 +37 +Package_SO +HSOP-36-1EP_11.0x15.9mm_P0.65mm_SlugUp +HSOP 11.0x15.9mm Pitch 0.65mm Slug Up (PowerSO-36) [JEDEC MO-166] (http://www.st.com/resource/en/datasheet/vn808cm-32-e.pdf, http://www.st.com/resource/en/application_note/cd00003801.pdf) +HSOP 11.0 x 15.9mm Pitch 0.65mm +0 +36 +36 +Package_SO +HTSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.4x3.2mm +HTSOP, 8 Pin (https://media.digikey.com/pdf/Data%20Sheets/Rohm%20PDFs/BD9G341EFJ.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSOP SO +0 +13 +9 +Package_SO +HTSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.4x3.2mm_ThermalVias +HTSOP, 8 Pin (https://media.digikey.com/pdf/Data%20Sheets/Rohm%20PDFs/BD9G341EFJ.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSOP SO +0 +20 +9 +Package_SO +HTSSOP-14-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask3x3.1mm +HTSSOP, 14 Pin (http://www.ti.com/lit/ds/symlink/lm5161.pdf#page=34), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +20 +15 +Package_SO +HTSSOP-14-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask3x3.1mm_ThermalVias +HTSSOP, 14 Pin (http://www.ti.com/lit/ds/symlink/lm5161.pdf#page=34), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +36 +15 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm +16-Lead Plastic HTSSOP (4.4x5x1.2mm); Thermal pad; (http://www.ti.com/lit/ds/symlink/drv8833.pdf) +SSOP 0.65 +0 +29 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask2.46x2.31mm +HTSSOP, 16 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +20 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask2.46x2.31mm_ThermalVias +HTSSOP, 16 Pin (http://www.analog.com/media/en/technical-documentation/data-sheets/LTC7810.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +27 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3.4x5mm_Mask3x3mm_ThermalVias +16-Lead Plastic HTSSOP (4.4x5x1.2mm); Thermal pad with vias; (http://www.ti.com/lit/ds/symlink/drv8800.pdf) +SSOP 0.65 +0 +46 +17 +Package_SO +HTSSOP-16-1EP_4.4x5mm_P0.65mm_EP3x3mm +HTSSOP, 16 Pin (https://www.st.com/resource/en/datasheet/stp08cp05.pdf#page=20), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +21 +17 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP2.85x4mm +HTSSOP, 20 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0108.PDF U20E-1), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +23 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm +20-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body [HTSSOP], with thermal pad with vias +HTSSOP 0.65 +0 +29 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.4x3.7mm +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/bq24006.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +24 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.75x3.43mm +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=37&zoom=160,-90,3), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +26 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.75x3.43mm_ThermalVias +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=37&zoom=160,-90,3), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +42 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.75x3.43mm_ThermalVias_HandSolder +HTSSOP, 20 Pin (http://www.ti.com/lit/ds/symlink/tlc5971.pdf#page=37&zoom=160,-90,3), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +42 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.96x2.96mm +HTSSOP, 20 Pin (https://www.ti.com/lit/ds/symlink/tps2663.pdf#page=49), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +23 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_Mask2.96x2.96mm_ThermalVias +HTSSOP, 20 Pin (https://www.ti.com/lit/ds/symlink/tps2663.pdf#page=49), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +42 +21 +Package_SO +HTSSOP-20-1EP_4.4x6.5mm_P0.65mm_EP3.4x6.5mm_ThermalVias +20-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body [HTSSOP], with thermal pad with vias +HTSSOP 0.65 +0 +45 +21 +Package_SO +HTSSOP-24-1EP_4.4x7.8mm_P0.65mm_EP3.2x5mm +HTSSOP, 24 Pin (https://www.st.com/resource/en/datasheet/stp16cp05.pdf#page=25), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +31 +25 +Package_SO +HTSSOP-24-1EP_4.4x7.8mm_P0.65mm_EP3.4x7.8mm_Mask2.4x4.68mm +HTSSOP, 24 Pin (http://www.ti.com/lit/ds/symlink/tps703.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +28 +25 +Package_SO +HTSSOP-24-1EP_4.4x7.8mm_P0.65mm_EP3.4x7.8mm_Mask2.4x4.68mm_ThermalVias +HTSSOP, 24 Pin (http://www.ti.com/lit/ds/symlink/tps703.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +47 +25 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP2.85x5.4mm +HTSSOP, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0108.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +30 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP2.85x5.4mm_ThermalVias +HTSSOP, 28 Pin (https://pdfserv.maximintegrated.com/package_dwgs/21-0108.PDF), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +41 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +39 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm_Mask2.4x6.17mm +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +40 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm_Mask2.4x6.17mm_ThermalVias +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +55 +29 +Package_SO +HTSSOP-28-1EP_4.4x9.7mm_P0.65mm_EP3.4x9.5mm_ThermalVias +HTSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; thermal pad +TSSOP HTSSOP 0.65 thermal pad +0 +58 +29 +Package_SO +HTSSOP-32-1EP_6.1x11mm_P0.65mm_EP5.2x11mm_Mask4.11x4.36mm +HTSSOP32: plastic thin shrink small outline package; 32 leads; body width 6.1 mm; lead pitch 0.65 mm (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot487-1_po.pdf) +SSOP 0.65 PowerPAD +0 +43 +33 +Package_SO +HTSSOP-32-1EP_6.1x11mm_P0.65mm_EP5.2x11mm_Mask4.11x4.36mm_ThermalVias +HTSSOP32: plastic thin shrink small outline package; 32 leads; body width 6.1 mm; lead pitch 0.65 mm (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot487-1_po.pdf) +SSOP 0.65 PowerPAD +0 +83 +33 +Package_SO +HTSSOP-38-1EP_6.1x12.5mm_P0.65mm_EP5.2x12.5mm_Mask3.39x6.35mm +HTSSOP, 38 Pin (http://www.ti.com/lit/ds/symlink/tlc5951.pdf#page=47&zoom=140,-67,15), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +46 +39 +Package_SO +HTSSOP-38-1EP_6.1x12.5mm_P0.65mm_EP5.2x12.5mm_Mask3.39x6.35mm_ThermalVias +HTSSOP, 38 Pin (http://www.ti.com/lit/ds/symlink/tlc5951.pdf#page=47&zoom=140,-67,15), generated with kicad-footprint-generator ipc_gullwing_generator.py +HTSSOP SO +0 +87 +39 +Package_SO +HTSSOP-56-1EP_6.1x14mm_P0.5mm_EP3.61x6.35mm +HTSSOP56: plastic thin shrink small outline package http://www.ti.com/lit/ds/symlink/drv8301.pdf +HTSSOP 0.5 +0 +72 +57 +Package_SO +Infineon_PG-DSO-8-27_3.9x4.9mm_EP2.65x3mm +Infineon PG-DSO, 8 Pin (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-8-27), generated with kicad-footprint-generator ipc_gullwing_generator.py +Infineon PG-DSO SO +0 +13 +9 +Package_SO +Infineon_PG-DSO-8-27_3.9x4.9mm_EP2.65x3mm_ThermalVias +Infineon PG-DSO, 8 Pin (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-8-27), generated with kicad-footprint-generator ipc_gullwing_generator.py +Infineon PG-DSO SO +0 +23 +9 +Package_SO +Infineon_PG-DSO-8-43 +Infineon_PG-DSO-8-43 +DSO DSO-8 SOIC SOIC-8 +0 +12 +9 +Package_SO +Infineon_PG-DSO-12-9 +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-9/) +PG-DSO +0 +23 +13 +Package_SO +Infineon_PG-DSO-12-9_ThermalVias +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-9/) +PG-DSO +0 +42 +13 +Package_SO +Infineon_PG-DSO-12-11 +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-11/) +PG-DSO +0 +23 +13 +Package_SO +Infineon_PG-DSO-12-11_ThermalVias +Infineon PG-DSO 12 pin, exposed pad: 4.5x8.1mm, with thermal vias (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-12-11/) +PG-DSO +0 +42 +13 +Package_SO +Infineon_PG-DSO-20-30 +Infineon SO package 20pin, exposed pad 4.5x7mm (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-71/) +DSO-20 +0 +31 +21 +Package_SO +Infineon_PG-DSO-20-30_ThermalVias +Infineon SO package 20pin, exposed pad 4.5x7mm (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-71/) +DSO-20 +0 +45 +21 +Package_SO +Infineon_PG-DSO-20-32 +Infineon SO package 20pin without exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-32/) +DSO-20 +0 +20 +20 +Package_SO +Infineon_PG-DSO-20-85 +Infineon SO package 20pin with exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-85/) +DSO-20 +0 +31 +21 +Package_SO +Infineon_PG-DSO-20-85_ThermalVias +Infineon SO package 20pin with exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-85/) +DSO-20 +0 +113 +21 +Package_SO +Infineon_PG-DSO-20-87 +Infineon SO package 20pin without exposed pad (https://www.infineon.com/cms/en/product/packages/PG-DSO/PG-DSO-20-87/) +DSO-20 +0 +20 +20 +Package_SO +Infineon_PG-TSDSO-14-22 +Infineon_PG-TSDSO-14-22 +Infineon TSDSO 14-22 +0 +17 +15 +Package_SO +Linear_MSOP-12-16-1EP_3x4mm_P0.5mm +12-Lead Plastic Micro Small Outline Package (MS) [MSOP], variant of MSOP-16 (see http://cds.linear.com/docs/en/datasheet/3630fd.pdf) +SSOP 0.5 +0 +15 +13 +Package_SO +Linear_MSOP-12-16_3x4mm_P0.5mm +12-Lead Plastic Micro Small Outline Package (MS) [MSOP], variant of MSOP-16 (see https://www.analog.com/media/en/technical-documentation/data-sheets/3748fb.pdf) +SSOP 0.5 +0 +12 +12 +Package_SO +MFSOP6-4_4.4x3.6mm_P1.27mm +https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.4pin%20MFSOP6.html +MFSOP 4 pin SMD +0 +4 +4 +Package_SO +MFSOP6-5_4.4x3.6mm_P1.27mm +https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.5pin%20MFSOP6.html +MFSOP 4 pin SMD +0 +5 +5 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.68x1.88mm +MSOP, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4440fb.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +13 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.68x1.88mm_ThermalVias +MSOP, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/4440fb.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +18 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.73x1.85mm +MSOP, 8 Pin (http://www.ti.com/lit/ds/symlink/lm25085.pdf#page=32), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +13 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.73x1.85mm_ThermalVias +MSOP, 8 Pin (http://www.ti.com/lit/ds/symlink/lm25085.pdf#page=32), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +18 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.95x2.15mm +MSOP, 8 Pin (http://www.st.com/resource/en/datasheet/pm8834.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +13 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP1.95x2.15mm_ThermalVias +MSOP, 8 Pin (http://www.st.com/resource/en/datasheet/pm8834.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +18 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP2.5x3mm_Mask1.73x2.36mm +MSOP, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf#page=15), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +14 +9 +Package_SO +MSOP-8-1EP_3x3mm_P0.65mm_EP2.5x3mm_Mask1.73x2.36mm_ThermalVias +MSOP, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/mic5355_6.pdf#page=15), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +19 +9 +Package_SO +MSOP-8_3x3mm_P0.65mm +MSOP, 8 Pin (https://www.jedec.org/system/files/docs/mo-187F.pdf variant AA), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +8 +8 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.68x1.88mm +MSOP, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3805fg.pdf#page=18), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +15 +11 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.68x1.88mm_ThermalVias +MSOP, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3805fg.pdf#page=18), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +20 +11 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.73x1.98mm +MSOP, 10 Pin (www.allegromicro.com/~/media/Files/Datasheets/A4952-3-Datasheet.ashx?la=en#page=10), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +15 +11 +Package_SO +MSOP-10-1EP_3x3mm_P0.5mm_EP1.73x1.98mm_ThermalVias +MSOP, 10 Pin (www.allegromicro.com/~/media/Files/Datasheets/A4952-3-Datasheet.ashx?la=en#page=10), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +20 +11 +Package_SO +MSOP-10_3x3mm_P0.5mm +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +10 +10 +Package_SO +MSOP-12-1EP_3x4mm_P0.65mm_EP1.65x2.85mm +MSOP, 12 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3652fe.pdf#page=24), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +17 +13 +Package_SO +MSOP-12-1EP_3x4mm_P0.65mm_EP1.65x2.85mm_ThermalVias +MSOP, 12 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3652fe.pdf#page=24), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +24 +13 +Package_SO +MSOP-12-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +19 +13 +Package_SO +MSOP-12-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm_ThermalVias +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +25 +13 +Package_SO +MSOP-12-16_3x4mm_P0.5mm +10-Lead Plastic Micro Small Outline Package (MS) [MSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.5 +0 +12 +12 +Package_SO +MSOP-12_3x4mm_P0.65mm +MSOP, 12 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/6957fb.pdf#page=36), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +12 +12 +Package_SO +MSOP-16-1EP_3x4.039mm_P0.5mm_EP1.651x2.845mm +MSOP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-msop/05081667_F_MSE16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +21 +17 +Package_SO +MSOP-16-1EP_3x4.039mm_P0.5mm_EP1.651x2.845mm_ThermalVias +MSOP, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-msop/05081667_F_MSE16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +28 +17 +Package_SO +MSOP-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm +MSOP, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +21 +17 +Package_SO +MSOP-16-1EP_3x4mm_P0.5mm_EP1.65x2.85mm_ThermalVias +MSOP, 16 Pin (http://cds.linear.com/docs/en/datasheet/37551fd.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +28 +17 +Package_SO +MSOP-16_3x4.039mm_P0.5mm +MSOP, 16 Pin (http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-msop/05081669_A_MS16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +16 +16 +Package_SO +MSOP-16_3x4mm_P0.5mm +MSOP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/436412f.pdf#page=22), generated with kicad-footprint-generator ipc_gullwing_generator.py +MSOP SO +0 +16 +16 +Package_SO +ONSemi_SO-8FL_488AA +ON Semi DFN5 5x6mm 1.27P SO-8FL CASE 488A https://www.onsemi.com/pub/Collateral/488AA.PDF +ON Semi DFN5 5x6mm 1.27P SO-8FL CASE 488A +0 +5 +5 +Package_SO +OnSemi_Micro8 +ON Semiconductor Micro8 (Case846A-02): https://www.onsemi.com/pub/Collateral/846A-02.PDF +micro8 +0 +8 +8 +Package_SO +PSOP-44_16.9x27.17mm_P1.27mm +PSOP44: plastic thin shrink small outline package; 44 leads; body width 16.90 mm +PSOP 1.27 +0 +44 +44 +Package_SO +PowerIntegrations_SO-8 +Power-Integrations variant of 8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], see https://ac-dc.power.com/sites/default/files/product-docs/senzero_family_datasheet.pdf +SOIC 1.27 +0 +8 +8 +Package_SO +PowerIntegrations_SO-8B +Power-Integrations variant of 8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], see https://www.mouser.com/ds/2/328/linkswitch-pl_family_datasheet-12517.pdf +SOIC 1.27 +0 +7 +7 +Package_SO +PowerIntegrations_SO-8C +Power-Integrations variant of 8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], see https://www.mouser.com/ds/2/328/linkswitch-pl_family_datasheet-12517.pdf +SOIC 1.27 +0 +7 +7 +Package_SO +PowerIntegrations_eSOP-12B +eSOP-12B SMT Flat Package with Heatsink Tab, see https://ac-dc.power.com/sites/default/files/product-docs/topswitch-jx_family_datasheet.pdf +Power Integrations K Package +0 +12 +12 +Package_SO +PowerPAK_SO-8_Dual +PowerPAK SO-8 Dual (https://www.vishay.com/docs/71655/powerpak.pdf, https://www.vishay.com/docs/72600/72600.pdf) +PowerPAK SO-8 Dual +0 +10 +6 +Package_SO +PowerPAK_SO-8_Single +PowerPAK SO-8 Single (https://www.vishay.com/docs/71655/powerpak.pdf, https://www.vishay.com/docs/72599/72599.pdf) +PowerPAK SO-8 Single +0 +9 +5 +Package_SO +QSOP-16_3.9x4.9mm_P0.635mm +16-Lead Plastic Shrink Small Outline Narrow Body (QR)-.150" Body [QSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.635 +0 +16 +16 +Package_SO +QSOP-20_3.9x8.7mm_P0.635mm +20-Lead Plastic Shrink Small Outline Narrow Body (http://www.analog.com/media/en/technical-documentation/data-sheets/ADuM7640_7641_7642_7643.pdf) +QSOP 0.635 +0 +20 +20 +Package_SO +QSOP-24_3.9x8.7mm_P0.635mm +24-Lead Plastic Shrink Small Outline Narrow Body (QR)-.150" Body [QSOP] (see Microchip Packaging Specification 00000049CH.pdf) +QSOP 0.635 +0 +24 +24 +Package_SO +SC-74-6_1.5x2.9mm_P0.95mm +SC-74, 6 Pin (https://www.nxp.com/docs/en/package-information/SOT457.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SC-74 SO +0 +6 +6 +Package_SO +SO-4_4.4x2.3mm_P1.27mm +4-Lead Plastic Small Outline (SO), see http://datasheet.octopart.com/OPIA403BTRE-Optek-datasheet-5328560.pdf +SO SOIC 1.27 +0 +4 +4 +Package_SO +SO-4_4.4x3.6mm_P2.54mm +4-Lead Plastic Small Outline (SO), see https://www.elpro.org/de/index.php?controller=attachment&id_attachment=339 +SO SOIC 2.54 +0 +4 +4 +Package_SO +SO-4_4.4x3.9mm_P2.54mm +SO, 4 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=10047&prodName=TLP3123), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +4 +4 +Package_SO +SO-4_4.4x4.3mm_P2.54mm +4-Lead Plastic Small Outline (SO), see https://docs.broadcom.com/docs/AV02-0173EN +SO SOIC 2.54 +0 +4 +4 +Package_SO +SO-4_7.6x3.6mm_P2.54mm +4-Lead Plastic Small Outline (SO) (http://www.everlight.com/file/ProductFile/201407061745083848.pdf) +SO SOIC 2.54 +0 +4 +4 +Package_SO +SO-5_4.4x3.6mm_P1.27mm +5-Lead Plastic Small Outline (SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SO SOIC 1.27 +0 +5 +5 +Package_SO +SO-6L_10x3.84mm_P1.27mm +6-pin plasic small outline 7,5mm long https://toshiba.semicon-storage.com/info/docget.jsp?did=53548&prodName=TLP2770 +SO-6L +0 +6 +6 +Package_SO +SO-6_4.4x3.6mm_P1.27mm +6-Lead Plastic Small Outline (SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SO SOIC 1.27 +0 +6 +6 +Package_SO +SO-8_3.9x4.9mm_P1.27mm +SO, 8 Pin (https://www.nxp.com/docs/en/data-sheet/PCF8523.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +8 +8 +Package_SO +SO-8_5.3x6.2mm_P1.27mm +SO, 8 Pin (https://www.ti.com/lit/ml/msop001a/msop001a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +8 +8 +Package_SO +SO-14_3.9x8.65mm_P1.27mm +SO, 14 Pin (https://www.st.com/resource/en/datasheet/l6491.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +14 +14 +Package_SO +SO-14_5.3x10.2mm_P1.27mm +SO, 14 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +14 +14 +Package_SO +SO-16_3.9x9.9mm_P1.27mm +SO, 16 Pin (https://www.nxp.com/docs/en/package-information/SOT109-1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +16 +16 +Package_SO +SO-16_5.3x10.2mm_P1.27mm +SO, 16 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +16 +16 +Package_SO +SO-20-1EP_7.52x12.825mm_P1.27mm_EP6.045x12.09mm_Mask3.56x4.47mm +SO, 20 Pin (http://www.ti.com/lit/ds/symlink/opa569.pdf, http://www.ti.com/lit/an/slma004b/slma004b.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +23 +21 +Package_SO +SO-20-1EP_7.52x12.825mm_P1.27mm_EP6.045x12.09mm_Mask3.56x4.47mm_ThermalVias +SO, 20 Pin (http://www.ti.com/lit/ds/symlink/opa569.pdf, http://www.ti.com/lit/an/slma004b/slma004b.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +51 +21 +Package_SO +SO-20_5.3x12.6mm_P1.27mm +SO, 20 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +20 +20 +Package_SO +SO-20_12.8x7.5mm_P1.27mm +SO-20, 12.8x7.5mm, https://www.nxp.com/docs/en/data-sheet/SA605.pdf +S0-20 +0 +20 +20 +Package_SO +SO-24_5.3x15mm_P1.27mm +SO, 24 Pin (https://www.ti.com/lit/ml/msop002a/msop002a.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SO SO +0 +24 +24 +Package_SO +SOIC-4_4.55x2.6mm_P1.27mm +SOIC, 4 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=12884&prodName=TLP291), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +4 +4 +Package_SO +SOIC-4_4.55x3.7mm_P2.54mm +SOIC, 6 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=11791&prodName=TLP185), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +4 +4 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.29x3mm +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.29x3mm_ThermalVias +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.3mm +SOIC, 8 Pin (http://www.allegromicro.com/~/media/Files/Datasheets/A4950-Datasheet.ashx#page=8), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.3mm_ThermalVias +SOIC, 8 Pin (http://www.allegromicro.com/~/media/Files/Datasheets/A4950-Datasheet.ashx#page=8), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.81mm +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.41x3.81mm_ThermalVias +SOIC, 8 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/ada4898-1_4898-2.pdf#page=29), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.95x4.9mm_Mask2.71x3.4mm +SOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lm5017.pdf#page=31), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +14 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.95x4.9mm_Mask2.71x3.4mm_ThermalVias +SOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lm5017.pdf#page=31), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +23 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.514x3.2mm +SOIC, 8 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/hip2100.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +13 +9 +Package_SO +SOIC-8-1EP_3.9x4.9mm_P1.27mm_EP2.514x3.2mm_ThermalVias +SOIC, 8 Pin (https://www.renesas.com/eu/en/www/doc/datasheet/hip2100.pdf#page=13), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +9 +Package_SO +SOIC-8-N7_3.9x4.9mm_P1.27mm +8-Lead Plastic Small Outline (SN) - Narrow, 3.90 mm Body [SOIC], pin 7 removed (Microchip Packaging Specification 00000049BS.pdf, http://www.onsemi.com/pub/Collateral/NCP1207B.PDF) +SOIC 1.27 +0 +7 +7 +Package_SO +SOIC-8_3.9x4.9mm_P1.27mm +SOIC, 8 Pin (JEDEC MS-012AA, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_narrow-r/r_8.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-8_5.23x5.23mm_P1.27mm +SOIC, 8 Pin (http://www.winbond.com/resource-files/w25q32jv%20revg%2003272018%20plus.pdf#page=68), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-8_5.275x5.275mm_P1.27mm +SOIC, 8 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/20005045C.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-8_7.5x5.85mm_P1.27mm +SOIC, 8 Pin (http://www.ti.com/lit/ml/mpds382b/mpds382b.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +8 +8 +Package_SO +SOIC-14-16_3.9x9.9mm_P1.27mm +SOIC, 16 Pin package with pin 2 and 13 removed for voltage clearance (UCC256301, https://www.ti.com/lit/ds/symlink/ucc256301.pdf) +SOIC SO +0 +14 +14 +Package_SO +SOIC-14W_7.5x9mm_P1.27mm +SOIC, 14 Pin (JEDEC MS-013AF, https://www.analog.com/media/en/package-pcb-resources/package/54614177245586rw_14.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +14 +14 +Package_SO +SOIC-14_3.9x8.7mm_P1.27mm +SOIC, 14 Pin (JEDEC MS-012AB, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_narrow-r/r_14.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +14 +14 +Package_SO +SOIC-16W-12_7.5x10.3mm_P1.27mm +SOIC-16 With 12 Pin Placed - Wide, 7.50 mm Body [SOIC] (https://docs.broadcom.com/docs/AV02-0169EN) +SOIC 1.27 16 12 Wide +0 +12 +12 +Package_SO +SOIC-16W_5.3x10.2mm_P1.27mm +16-Lead Plastic Small Outline (SO) - Wide, 5.3 mm Body (http://www.ti.com/lit/ml/msop002a/msop002a.pdf) +SOIC 1.27 +0 +16 +16 +Package_SO +SOIC-16W_7.5x10.3mm_P1.27mm +SOIC, 16 Pin (JEDEC MS-013AA, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_wide-rw/rw_16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-16W_7.5x12.8mm_P1.27mm +SOIC, 16 Pin (https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ri_soic_ic/ri_16_1.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-16_3.9x9.9mm_P1.27mm +SOIC, 16 Pin (JEDEC MS-012AC, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_narrow-r/r_16.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-16_4.55x10.3mm_P1.27mm +SOIC, 16 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=12858&prodName=TLP291-4), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +16 +16 +Package_SO +SOIC-18W_7.5x11.6mm_P1.27mm +SOIC, 18 Pin (JEDEC MS-013AB, https://www.analog.com/media/en/package-pcb-resources/package/33254132129439rw_18.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +18 +18 +Package_SO +SOIC-20W_7.5x12.8mm_P1.27mm +SOIC, 20 Pin (JEDEC MS-013AC, https://www.analog.com/media/en/package-pcb-resources/package/233848rw_20.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +20 +20 +Package_SO +SOIC-24W_7.5x15.4mm_P1.27mm +SOIC, 24 Pin (JEDEC MS-013AD, https://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/soic_wide-rw/RW_24.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +24 +24 +Package_SO +SOIC-28W_7.5x17.9mm_P1.27mm +SOIC, 28 Pin (JEDEC MS-013AE, https://www.analog.com/media/en/package-pcb-resources/package/35833120341221rw_28.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +28 +28 +Package_SO +SOIC-28W_7.5x18.7mm_P1.27mm +SOIC, 28 Pin (https://www.akm.com/akm/en/file/datasheet/AK5394AVS.pdf#page=23), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOIC SO +0 +28 +28 +Package_SO +SOIJ-8_5.3x5.3mm_P1.27mm +8-Lead Plastic Small Outline (SM) - Medium, 5.28 mm Body [SOIC] (see Microchip Packaging Specification 00000049BS.pdf) +SOIC 1.27 +0 +8 +8 +Package_SO +SOJ-36_10.16x23.49mm_P1.27mm +SOJ, 36 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOJ SO +0 +36 +36 +Package_SO +SOP-4_3.8x4.1mm_P2.54mm +SOP, 4 Pin (http://www.ixysic.com/home/pdfs.nsf/www/CPC1017N.pdf/$file/CPC1017N.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +4 +4 +Package_SO +SOP-4_4.4x2.6mm_P1.27mm +SOP, 4 Pin (http://www.vishay.com/docs/83510/tcmt1100.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +4 +4 +Package_SO +SOP-8-1EP_4.57x4.57mm_P1.27mm_EP4.57x4.45mm +SOP, 8 Pin (https://ww2.minicircuits.com/case_style/XX112.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +13 +9 +Package_SO +SOP-8-1EP_4.57x4.57mm_P1.27mm_EP4.57x4.45mm_ThermalVias +SOP, 8 Pin (https://ww2.minicircuits.com/case_style/XX112.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +20 +9 +Package_SO +SOP-8_3.9x4.9mm_P1.27mm +SOP, 8 Pin (http://www.macronix.com/Lists/Datasheet/Attachments/7534/MX25R3235F,%20Wide%20Range,%2032Mb,%20v1.6.pdf#page=79), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-8_3.76x4.96mm_P1.27mm +SOP, 8 Pin (https://ww2.minicircuits.com/case_style/XX211.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-8_5.28x5.23mm_P1.27mm +SOP, 8 Pin (http://www.macronix.com/Lists/Datasheet/Attachments/7534/MX25R3235F,%20Wide%20Range,%2032Mb,%20v1.6.pdf#page=80), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-8_6.62x9.15mm_P2.54mm +SOP, 8 Pin (http://www.ti.com/lit/ds/symlink/iso1050.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +8 +8 +Package_SO +SOP-16_3.9x9.9mm_P1.27mm +SOP, 16 Pin (https://www.diodes.com/assets/Datasheets/PAM8403.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +16 +16 +Package_SO +SOP-16_4.4x10.4mm_P1.27mm +16-Lead Plastic Small Outline http://www.vishay.com/docs/49633/sg2098.pdf +SOP 1.27 +0 +16 +16 +Package_SO +SOP-16_4.55x10.3mm_P1.27mm +SOP, 16 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=12855&prodName=TLP290-4), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +16 +16 +Package_SO +SOP-18_7x12.5mm_P1.27mm +SOP, 18 Pin (https://toshiba.semicon-storage.com/info/docget.jsp?did=30523), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +18 +18 +Package_SO +SOP-20_7.5x12.8mm_P1.27mm +SOP, 20 Pin (https://www.holtek.com/documents/10179/116723/sop20-300.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +20 +20 +Package_SO +SOP-24_7.5x15.4mm_P1.27mm +SOP, 24 Pin (http://www.issi.com/WW/pdf/31FL3218.pdf#page=14), generated with kicad-footprint-generator ipc_gullwing_generator.py +SOP SO +0 +24 +24 +Package_SO +SSO-4_6.7x5.1mm_P2.54mm_Clearance8mm +4-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://www.vishay.com/docs/84299/vor1142b4.pdf +SSO Stretched SO SOIC 2.54 +0 +4 +4 +Package_SO +SSO-6_6.8x4.6mm_P1.27mm_Clearance7mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC 1.27 +0 +6 +6 +Package_SO +SSO-6_6.8x4.6mm_P1.27mm_Clearance8mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC 1.27 +0 +6 +6 +Package_SO +SSO-8_6.7x9.8mm_P2.54mm_Clearance8mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://www.vishay.com/docs/83831/lh1533ab.pdf +SSO Stretched SO SOIC Pitch 2.54 +0 +8 +8 +Package_SO +SSO-8_6.8x5.9mm_P1.27mm_Clearance7mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSO-8_6.8x5.9mm_P1.27mm_Clearance8mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSO-8_9.6x6.3mm_P1.27mm_Clearance10.5mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSO-8_13.6x6.3mm_P1.27mm_Clearance14.2mm +8-Lead Plastic Stretched Small Outline (SSO/Stretched SO), see https://docs.broadcom.com/cs/Satellite?blobcol=urldata&blobheader=application%2Fpdf&blobheadername1=Content-Disposition&blobheadername2=Content-Type&blobheadername3=MDT-Type&blobheadervalue1=attachment%3Bfilename%3DIPD-Selection-Guide_AV00-0254EN_030617.pdf&blobheadervalue2=application%2Fx-download&blobheadervalue3=abinary%253B%2Bcharset%253DUTF-8&blobkey=id&blobnocache=true&blobtable=MungoBlobs&blobwhere=1430884105675&ssbinary=true +SSO Stretched SO SOIC Pitch 1.27 +0 +8 +8 +Package_SO +SSOP-8_2.95x2.8mm_P0.65mm +SSOP-8 2.9 x2.8mm Pitch 0.65mm +SSOP-8 2.95x2.8mm Pitch 0.65mm +0 +8 +8 +Package_SO +SSOP-8_3.9x5.05mm_P1.27mm +SSOP, 8 Pin (http://www.fujitsu.com/downloads/MICRO/fsa/pdf/products/memory/fram/MB85RS16-DS501-00014-6v0-E.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +8 +8 +Package_SO +SSOP-8_3.95x5.21x3.27mm_P1.27mm +SSOP-8 3.95x5.21x3.27mm Pitch 1.27mm +SSOP-8 3.95x5.21x3.27mm 1.27mm +0 +8 +8 +Package_SO +SSOP-8_5.25x5.24mm_P1.27mm +SSOP, 8 Pin (http://www.fujitsu.com/ca/en/Images/MB85RS2MT-DS501-00023-1v0-E.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +8 +8 +Package_SO +SSOP-10_3.9x4.9mm_P1.00mm +10-Lead SSOP, 3.9 x 4.9mm body, 1.00mm pitch (http://www.st.com/resource/en/datasheet/viper01.pdf) +SSOP 3.9 4.9 1.00 +0 +10 +10 +Package_SO +SSOP-14_5.3x6.2mm_P0.65mm +SSOP14: plastic shrink small outline package; 14 leads; body width 5.3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot337-1_po.pdf) +SSOP 0.65 +0 +14 +14 +Package_SO +SSOP-16_3.9x4.9mm_P0.635mm +SSOP16: plastic shrink small outline package; 16 leads; body width 3.9 mm; lead pitch 0.635; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot519-1_po.pdf) +SSOP 0.635 +0 +16 +16 +Package_SO +SSOP-16_4.4x5.2mm_P0.65mm +SSOP16: plastic shrink small outline package; 16 leads; body width 4.4 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot369-1_po.pdf) +SSOP 0.65 +0 +16 +16 +Package_SO +SSOP-16_5.3x6.2mm_P0.65mm +SSOP16: plastic shrink small outline package; 16 leads; body width 5.3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot338-1_po.pdf) +SSOP 0.65 +0 +16 +16 +Package_SO +SSOP-18_4.4x6.5mm_P0.65mm +SSOP18: plastic shrink small outline package; 18 leads; body width 4.4 mm (http://toshiba.semicon-storage.com/info/docget.jsp?did=30523&prodName=TBD62783APG) +SSOP 0.65 +0 +18 +18 +Package_SO +SSOP-20_3.9x8.7mm_P0.635mm +SSOP20: plastic shrink small outline package; 24 leads; body width 3.9 mm; lead pitch 0.635; (see http://www.ftdichip.com/Support/Documents/DataSheets/ICs/DS_FT231X.pdf) +SSOP 0.635 +0 +20 +20 +Package_SO +SSOP-20_4.4x6.5mm_P0.65mm +SSOP20: plastic shrink small outline package; 20 leads; body width 4.4 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot266-1_po.pdf) +SSOP 0.65 +0 +20 +20 +Package_SO +SSOP-20_5.3x7.2mm_P0.65mm +SSOP, 20 Pin (http://ww1.microchip.com/downloads/en/DeviceDoc/40001800C.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +20 +20 +Package_SO +SSOP-24_3.9x8.7mm_P0.635mm +SSOP24: plastic shrink small outline package; 24 leads; body width 3.9 mm; lead pitch 0.635; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot556-1_po.pdf) +SSOP 0.635 +0 +24 +24 +Package_SO +SSOP-24_5.3x8.2mm_P0.65mm +24-Lead Plastic Shrink Small Outline (SS)-5.30 mm Body [SSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.65 +0 +24 +24 +Package_SO +SSOP-28_3.9x9.9mm_P0.635mm +SSOP28: plastic shrink small outline package; 28 leads; body width 3.9 mm; lead pitch 0.635; (see http://cds.linear.com/docs/en/datasheet/38901fb.pdf) +SSOP 0.635 +0 +28 +28 +Package_SO +SSOP-28_5.3x10.2mm_P0.65mm +28-Lead Plastic Shrink Small Outline (SS)-5.30 mm Body [SSOP] (see Microchip Packaging Specification 00000049BS.pdf) +SSOP 0.65 +0 +28 +28 +Package_SO +SSOP-32_11.305x20.495mm_P1.27mm +SSOP, 32 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +SSOP SO +0 +32 +32 +Package_SO +SSOP-44_5.3x12.8mm_P0.5mm +44-Lead Plastic Shrink Small Outline (SS)-5.30 mm Body [SSOP] (http://cds.linear.com/docs/en/datasheet/680313fa.pdf) +SSOP 0.5 +0 +44 +44 +Package_SO +SSOP-48_7.5x15.9mm_P0.635mm +SSOP48: plastic shrink small outline package; 48 leads; body width 7.5 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot370-1_po.pdf) +SSOP 0.635 +0 +48 +48 +Package_SO +SSOP-56_7.5x18.5mm_P0.635mm +SSOP56: plastic shrink small outline package; 56 leads; body width 7.5 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot371-1_po.pdf) +SSOP 0.635 +0 +56 +56 +Package_SO +STC_SOP-16_3.9x9.9mm_P1.27mm +STC SOP, 16 Pin (https://www.stcmicro.com/datasheet/STC15F2K60S2-en.pdf#page=156), generated with kicad-footprint-generator ipc_gullwing_generator.py +STC SOP SO +0 +16 +16 +Package_SO +ST_MultiPowerSO-30 +MultiPowerSO-30 3EP 16.0x17.2mm Pitch 1mm (http://www.st.com/resource/en/datasheet/vnh2sp30-e.pdf) +MultiPowerSO-30 3EP 16.0x17.2mm Pitch 1mm +0 +33 +33 +Package_SO +ST_PowerSSO-24_SlugDown +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7266p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm +0 +25 +25 +Package_SO +ST_PowerSSO-24_SlugDown_ThermalVias +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7266p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm +0 +38 +25 +Package_SO +ST_PowerSSO-24_SlugUp +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7266p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-24 1EP 7.5x10.3mm Pitch 0.8mm +0 +24 +24 +Package_SO +ST_PowerSSO-36_SlugDown +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7492p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm +0 +37 +37 +Package_SO +ST_PowerSSO-36_SlugDown_ThermalVias +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7492p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm +0 +50 +37 +Package_SO +ST_PowerSSO-36_SlugUp +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm [JEDEC MO-271] (http://www.st.com/resource/en/datasheet/tda7492p.pdf, http://freedatasheets.com/downloads/Technical%20Note%20Powersso24%20TN0054.pdf) +ST PowerSSO-36 1EP 7.5x10.3mm Pitch 0.8mm +0 +36 +36 +Package_SO +TI_SO-PowerPAD-8 +8-Lead Plastic PSOP, Exposed Die Pad (TI DDA0008B, see http://www.ti.com/lit/ds/symlink/lm3404.pdf) +SSOP 0.50 exposed pad +0 +12 +9 +Package_SO +TI_SO-PowerPAD-8_ThermalVias +8-pin HTSOP package with 1.27mm pin pitch, compatible with SOIC-8, 3.9x4.9mm² body, exposed pad, thermal vias with large copper area, as proposed in http://www.ti.com/lit/ds/symlink/tps5430.pdf +HTSOP 1.27 +0 +19 +9 +Package_SO +TSOP-5_1.65x3.05mm_P0.95mm +TSOP-5 package (comparable to TSOT-23), https://www.vishay.com/docs/71200/71200.pdf +Jedec MO-193C TSOP-5L +0 +5 +5 +Package_SO +TSOP-6_1.65x3.05mm_P0.95mm +TSOP-6 package (comparable to TSOT-23), https://www.vishay.com/docs/71200/71200.pdf +Jedec MO-193C TSOP-6L +0 +6 +6 +Package_SO +TSOP-I-28_11.8x8mm_P0.55mm +TSOP I, 28 pins, 18.8x8mm body, 0.55mm pitch, IPC-calculated pads (http://ww1.microchip.com/downloads/en/devicedoc/doc0807.pdf) +TSOP I 28 pins +0 +28 +28 +Package_SO +TSOP-I-32_11.8x8mm_P0.5mm +TSOP-I, 32 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSOP-I SO +0 +32 +32 +Package_SO +TSOP-I-32_18.4x8mm_P0.5mm +TSOP I, 32 pins, 18.4x8mm body (https://www.micron.com/~/media/documents/products/technical-note/nor-flash/tn1225_land_pad_design.pdf, http://www.fujitsu.com/downloads/MICRO/fma/pdfmcu/f32pm25.pdf) +TSOP I 32 +0 +32 +32 +Package_SO +TSOP-I-32_18.4x8mm_P0.5mm_Reverse +TSOP I, 32 pins, 18.4x8mm body (http://www.futurlec.com/Datasheet/Memory/628128.pdf), reverse mount +TSOP I 32 reverse +0 +32 +32 +Package_SO +TSOP-I-48_18.4x12mm_P0.5mm +TSOP I, 32 pins, 18.4x8mm body (https://www.micron.com/~/media/documents/products/technical-note/nor-flash/tn1225_land_pad_design.pdf) +TSOP I 32 +0 +48 +48 +Package_SO +TSOP-I-56_18.4x14mm_P0.5mm +TSOP I, 32 pins, 18.4x8mm body (https://www.micron.com/~/media/documents/products/technical-note/nor-flash/tn1225_land_pad_design.pdf) +TSOP I 32 +0 +56 +56 +Package_SO +TSOP-II-32_21.0x10.2mm_P1.27mm +32-lead plastic TSOP; Type II +TSOP-II 32 +0 +32 +32 +Package_SO +TSOP-II-44_10.16x18.41mm_P0.8mm +TSOP-II, 44 Pin (http://www.issi.com/WW/pdf/61-64C5128AL.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSOP-II SO +0 +44 +44 +Package_SO +TSOP-II-54_22.2x10.16mm_P0.8mm +54-lead TSOP typ II package +TSOPII TSOP2 +0 +54 +54 +Package_SO +TSSOP-4_4.4x5mm_P4mm +TSSOP, 4 Pin (https://www.onsemi.com/pub/Collateral/MDB8S-D.PDF#page=4), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +4 +4 +Package_SO +TSSOP-8_3x3mm_P0.65mm +TSSOP8: plastic thin shrink small outline package; 8 leads; body width 3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot505-1_po.pdf) +SSOP 0.65 +0 +8 +8 +Package_SO +TSSOP-8_4.4x3mm_P0.65mm +TSSOP, 8 Pin (JEDEC MO-153 Var AA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +8 +8 +Package_SO +TSSOP-10_3x3mm_P0.5mm +TSSOP10: plastic thin shrink small outline package; 10 leads; body width 3 mm; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot552-1_po.pdf) +SSOP 0.5 +0 +10 +10 +Package_SO +TSSOP-14-1EP_4.4x5mm_P0.65mm +14-Lead Plastic Thin Shrink Small Outline (ST)-4.4 mm Body [TSSOP] with exposed pad (http://cds.linear.com/docs/en/datasheet/34301fa.pdf) +SSOP 0.65 exposed pad +0 +18 +15 +Package_SO +TSSOP-14_4.4x5mm_P0.65mm +TSSOP, 14 Pin (JEDEC MO-153 Var AB-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +14 +14 +Package_SO +TSSOP-16-1EP_4.4x5mm_P0.65mm +FE Package; 16-Lead Plastic TSSOP (4.4mm); Exposed Pad Variation BB; (see Linear Technology 1956f.pdf) +SSOP 0.65 +0 +24 +17 +Package_SO +TSSOP-16_4.4x5mm_P0.65mm +TSSOP, 16 Pin (JEDEC MO-153 Var AB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +16 +16 +Package_SO +TSSOP-20_4.4x5mm_P0.5mm +TSSOP, 20 Pin (JEDEC MO-153 Var BA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +20 +20 +Package_SO +TSSOP-20_4.4x6.5mm_P0.65mm +TSSOP, 20 Pin (JEDEC MO-153 Var AC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +20 +20 +Package_SO +TSSOP-24_4.4x5mm_P0.4mm +TSSOP, 24 Pin (JEDEC MO-153 Var CA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-24_4.4x6.5mm_P0.5mm +TSSOP, 24 Pin (JEDEC MO-153 Var BB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-24_4.4x7.8mm_P0.65mm +TSSOP, 24 Pin (JEDEC MO-153 Var AD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-24_6.1x7.8mm_P0.65mm +TSSOP, 24 Pin (JEDEC MO-153 Var DA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +24 +24 +Package_SO +TSSOP-28-1EP_4.4x9.7mm_P0.65mm +TSSOP28: plastic thin shrink small outline package; 28 leads; body width 4.4 mm; Exposed Pad Variation; (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot361-1_po.pdf) +SSOP 0.65 +0 +36 +29 +Package_SO +TSSOP-28_4.4x7.8mm_P0.5mm +TSSOP, 28 Pin (JEDEC MO-153 Var BC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_4.4x9.7mm_P0.65mm +TSSOP, 28 Pin (JEDEC MO-153 Var AE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_6.1x7.8mm_P0.5mm +TSSOP, 28 Pin (JEDEC MO-153 Var EA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_6.1x9.7mm_P0.65mm +TSSOP, 28 Pin (JEDEC MO-153 Var DB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-28_8x9.7mm_P0.65mm +TSSOP, 28 Pin (JEDEC MO-153 Var GA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +28 +28 +Package_SO +TSSOP-30_4.4x7.8mm_P0.5mm +TSSOP, 30 Pin (JEDEC MO-153 Var BC-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +30 +30 +Package_SO +TSSOP-30_6.1x9.7mm_P0.65mm +TSSOP, 30 Pin (JEDEC MO-153 Var DB-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +30 +30 +Package_SO +TSSOP-32_4.4x6.5mm_P0.4mm +TSSOP, 32 Pin (JEDEC MO-153 Var CB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +32 +32 +Package_SO +TSSOP-32_6.1x11mm_P0.65mm +TSSOP, 32 Pin (JEDEC MO-153 Var DC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +32 +32 +Package_SO +TSSOP-32_8x11mm_P0.65mm +TSSOP, 32 Pin (JEDEC MO-153 Var GB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +32 +32 +Package_SO +TSSOP-36_4.4x7.8mm_P0.4mm +TSSOP, 36 Pin (JEDEC MO-153 Var CC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_4.4x9.7mm_P0.5mm +TSSOP, 36 Pin (JEDEC MO-153 Var BD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_6.1x7.8mm_P0.4mm +TSSOP, 36 Pin (JEDEC MO-153 Var FA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_6.1x9.7mm_P0.5mm +TSSOP, 36 Pin (JEDEC MO-153 Var EB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_6.1x12.5mm_P0.65mm +TSSOP, 36 Pin (JEDEC MO-153 Var DD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_8x9.7mm_P0.5mm +TSSOP, 36 Pin (JEDEC MO-153 Var HA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-36_8x12.5mm_P0.65mm +TSSOP, 36 Pin (JEDEC MO-153 Var GC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +36 +36 +Package_SO +TSSOP-38_4.4x9.7mm_P0.5mm +TSSOP, 38 Pin (JEDEC MO-153 Var BD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +38 +38 +Package_SO +TSSOP-38_6.1x12.5mm_P0.65mm +TSSOP, 38 Pin (JEDEC MO-153 Var DD-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +38 +38 +Package_SO +TSSOP-40_6.1x11mm_P0.5mm +TSSOP, 40 Pin (JEDEC MO-153 Var EC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-40_6.1x14mm_P0.65mm +TSSOP, 40 Pin (JEDEC MO-153 Var DE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-40_8x11mm_P0.5mm +TSSOP, 40 Pin (JEDEC MO-153 Var HB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-40_8x14mm_P0.65mm +TSSOP, 40 Pin (JEDEC MO-153 Var GD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +40 +40 +Package_SO +TSSOP-44_4.4x11.2mm_P0.5mm +TSSOP44: plastic thin shrink small outline package; 44 leads; body width 4.4 mm (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot510-1_po.pdf) +SSOP 0.5 +0 +44 +44 +Package_SO +TSSOP-44_4.4x11mm_P0.5mm +TSSOP, 44 Pin (JEDEC MO-153 Var BE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +44 +44 +Package_SO +TSSOP-44_6.1x11mm_P0.5mm +TSSOP, 44 Pin (JEDEC MO-153 Var EC-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +44 +44 +Package_SO +TSSOP-48_4.4x9.7mm_P0.4mm +TSSOP, 48 Pin (JEDEC MO-153 Var CD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_6.1x9.7mm_P0.4mm +TSSOP, 48 Pin (JEDEC MO-153 Var FB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_6.1x12.5mm_P0.5mm +TSSOP, 48 Pin (JEDEC MO-153 Var ED https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_8x9.7mm_P0.4mm +TSSOP, 48 Pin (JEDEC MO-153 Var JA https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-48_8x12.5mm_P0.5mm +TSSOP, 48 Pin (JEDEC MO-153 Var HC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +48 +48 +Package_SO +TSSOP-50_4.4x12.5mm_P0.5mm +TSSOP, 50 Pin (JEDEC MO-153 Var BF https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +50 +50 +Package_SO +TSSOP-52_6.1x11mm_P0.4mm +TSSOP, 52 Pin (JEDEC MO-153 Var FC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +52 +52 +Package_SO +TSSOP-52_8x11mm_P0.4mm +TSSOP, 52 Pin (JEDEC MO-153 Var JB https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +52 +52 +Package_SO +TSSOP-56_6.1x12.5mm_P0.4mm +TSSOP, 56 Pin (JEDEC MO-153 Var FD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-56_6.1x14mm_P0.5mm +TSSOP, 56 Pin (JEDEC MO-153 Var EE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-56_8x12.5mm_P0.4mm +TSSOP, 56 Pin (JEDEC MO-153 Var JC https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-56_8x14mm_P0.5mm +TSSOP, 56 Pin (JEDEC MO-153 Var HD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +56 +56 +Package_SO +TSSOP-60_8x12.5mm_P0.4mm +TSSOP, 60 Pin (JEDEC MO-153 Var JC-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +60 +60 +Package_SO +TSSOP-64_6.1x14mm_P0.4mm +TSSOP, 64 Pin (JEDEC MO-153 Var FE https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +64 +64 +Package_SO +TSSOP-64_6.1x17mm_P0.5mm +TSSOP, 64 Pin (JEDEC MO-153 Var EF https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +64 +64 +Package_SO +TSSOP-64_8x14mm_P0.4mm +TSSOP, 64 Pin (JEDEC MO-153 Var JD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +64 +64 +Package_SO +TSSOP-68_8x14mm_P0.4mm +TSSOP, 68 Pin (JEDEC MO-153 Var JD-1 https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +68 +68 +Package_SO +TSSOP-80_6.1x17mm_P0.4mm +TSSOP, 80 Pin (JEDEC MO-153 Var FF https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator ipc_gullwing_generator.py +TSSOP SO +0 +80 +80 +Package_SO +Texas_HSOP-8-1EP_3.9x4.9mm_P1.27mm +Texas Instruments HSOP 9, 1.27mm pitch, 3.9x4.9mm body, exposed pad, DDA0008J (http://www.ti.com/lit/ds/symlink/tps5430.pdf) +HSOP 1.27 +0 +11 +9 +Package_SO +Texas_HSOP-8-1EP_3.9x4.9mm_P1.27mm_ThermalVias +Texas Instruments HSOP 9, 1.27mm pitch, 3.9x4.9mm body, exposed pad, thermal vias, DDA0008J (http://www.ti.com/lit/ds/symlink/tps5430.pdf) +HSOP 1.27 +0 +20 +9 +Package_SO +Texas_HTSOP-8-1EP_3.9x4.9mm_P1.27mm_EP2.95x4.9mm_Mask2.4x3.1mm_ThermalVias +8-pin HTSOP package with 1.27mm pin pitch, compatible with SOIC-8, 3.9x4.9mm body, exposed pad, thermal vias, http://www.ti.com/lit/ds/symlink/drv8870.pdf +HTSOP 1.27 +0 +18 +9 +Package_SO +Texas_PWP0020A +20-Pin Thermally Enhanced Thin Shrink Small-Outline Package, Body 4.4x6.5x1.1mm, Pad 3.0x4.2mm, Texas Instruments (see http://www.ti.com/lit/ds/symlink/lm5118.pdf) +PWP HTSSOP 0.65mm +0 +25 +21 +Package_SO +Texas_R-PDSO-G8_EP2.95x4.9mm_Mask2.4x3.1mm +HSOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lmr14030.pdf#page=28, http://www.ti.com/lit/ml/msoi002j/msoi002j.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOIC SO +0 +16 +9 +Package_SO +Texas_R-PDSO-G8_EP2.95x4.9mm_Mask2.4x3.1mm_ThermalVias +HSOIC, 8 Pin (http://www.ti.com/lit/ds/symlink/lmr14030.pdf#page=28, http://www.ti.com/lit/ml/msoi002j/msoi002j.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +HSOIC SO +0 +23 +9 +Package_SO +Texas_R-PDSO-N5 +Plastic Small outline http://www.ti.com/lit/ml/mpds158c/mpds158c.pdf +SOT23 R-PDSO-N5 +0 +5 +5 +Package_SO +VSO-40_7.6x15.4mm_P0.762mm +VSO40: plastic very small outline package; 40 leads (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot158-1_po.pdf) +SSOP 0.762 +0 +40 +40 +Package_SO +VSO-56_11.1x21.5mm_P0.75mm +VSO56: plastic very small outline package; 56 leads (see NXP SSOP-TSSOP-VSO-REFLOW.pdf and sot190-1_po.pdf) +SSOP 0.75 +0 +56 +56 +Package_SO +VSSOP-8_2.3x2mm_P0.5mm +VSSOP-8 2.3x2mm Pitch 0.5mm +VSSOP-8 2.3x2mm Pitch 0.5mm +0 +8 +8 +Package_SO +VSSOP-8_2.4x2.1mm_P0.5mm +http://www.ti.com/lit/ml/mpds050d/mpds050d.pdf +VSSOP DCU R-PDSO-G8 Pitch0.5mm +0 +8 +8 +Package_SO +VSSOP-8_3.0x3.0mm_P0.65mm +VSSOP-8 3.0 x 3.0, http://www.ti.com/lit/ds/symlink/lm75b.pdf +VSSOP-8 3.0 x 3.0 +0 +8 +8 +Package_SO +VSSOP-10_3x3mm_P0.5mm +VSSOP, 10 Pin (http://www.ti.com/lit/ds/symlink/ads1115.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py +VSSOP SO +0 +10 +10 +Package_SO +Vishay_PowerPAK_1212-8_Dual +PowerPAK 1212-8 Dual (https://www.vishay.com/docs/71656/ppak12128.pdf, https://www.vishay.com/docs/72598/72598.pdf) +Vishay_PowerPAK_1212-8_Dual +0 +6 +6 +Package_SO +Vishay_PowerPAK_1212-8_Single +PowerPAK 1212-8 Single (https://www.vishay.com/docs/71656/ppak12128.pdf, https://www.vishay.com/docs/72597/72597.pdf) +Vishay PowerPAK 1212-8 Single +0 +5 +5 +Package_SO +Zetex_SM8 +Zetex, SMD, 8 pin package (http://datasheet.octopart.com/ZDT6758TA-Zetex-datasheet-68057.pdf) +Zetex SM8 +0 +8 +8 +Package_SON +Diodes_PowerDI3333-8 +Diodes Incorporated PowerDI3333-8, Plastic Dual Flat No Lead Package, 3.3x3.3x0.8mm Body, https://www.diodes.com/assets/Package-Files/PowerDI3333-8.pdf +PowerDI 0.65 +0 +13 +5 +Package_SON +Fairchild_DualPower33-6_3x3mm +Fairchild Power33 MOSFET package, 3x3mm (see https://www.fairchildsemi.com/datasheets/FD/FDMC8032L.pdf) +mosfet +0 +18 +6 +Package_SON +Fairchild_MicroPak-6_1.0x1.45mm_P0.5mm +Fairchild-specific MicroPak-6 1.0x1.45mm Pitch 0.5mm https://www.nxp.com/docs/en/application-note/AN10343.pdff +Fairchild-specific MicroPak-6 1.0x1.45mm Pitch 0.5mm +0 +6 +6 +Package_SON +Fairchild_MicroPak2-6_1.0x1.0mm_P0.35mm +Fairchild-specific MicroPak2-6 1.0x1.0mm Pitch 0.35mm https://www.nxp.com/docs/en/application-note/AN10343.pdff +Fairchild-specific MicroPak2-6 1.0x1.0mm Pitch 0.35mm +0 +6 +6 +Package_SON +HUSON-3-1EP_2x2mm_P1.3mm_EP1.1x1.6mm +HUSON, 3 Pin, SOT1061 (Ref: https://assets.nexperia.com/documents/data-sheet/PMEG2020CPA.pdf) +huson nolead SOT1061 +0 +4 +3 +Package_SON +HVSON-8-1EP_3x3mm_P0.65mm_EP1.6x2.4mm +HVSON, 8 Pin (https://www.nxp.com/docs/en/data-sheet/TJA1051.pdf#page=16), generated with kicad-footprint-generator ipc_noLead_generator.py +HVSON NoLead +0 +13 +9 +Package_SON +HVSON-8-1EP_4x4mm_P0.8mm_EP2.2x3.1mm +HVSON, 8 Pin (https://www.nxp.com/docs/en/data-sheet/PCF8523.pdf (page 57)), generated with kicad-footprint-generator ipc_noLead_generator.py +HVSON NoLead +0 +13 +9 +Package_SON +Infineon_PG-LSON-8-1 +https://www.infineon.com/cms/en/product/packages/PG-LSON/PG-LSON-8-1/ +PG-LSON-8-1 +0 +17 +9 +Package_SON +Infineon_PG-TISON-8-2 +Infineon, PG-TISON-8-2, 5x6x1.15mm, 1.27mm Pitch, Exposed Paddle, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-2/ +tison +0 +23 +7 +Package_SON +Infineon_PG-TISON-8-3 +Infineon, PG-TISON-8-2, 5x6x1.15mm, 1.27mm Pitch, Exposed Paddle, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-2/ +tison +0 +23 +7 +Package_SON +Infineon_PG-TISON-8-4 +Infineon, PG-TISON-8-4, 5x6x1.15mm, 1.27mm Pitch, Exposed Paddle, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-4/ +tison +0 +26 +8 +Package_SON +Infineon_PG-TISON-8-5 +Infineon, PG-TISON-8-5, 8x8x1.1mm, 1mm Pitch, https://www.infineon.com/cms/en/product/packages/PG-TISON/PG-TISON-8-5/ +tison +0 +34 +8 +Package_SON +NXP_XSON-16 +http://www.nxp.com/documents/outline_drawing/SOT1341-1.pdf +NXP XSON SOT-1341 +0 +16 +16 +Package_SON +ROHM_VML0806 +VML0806, Rohm (http://rohmfs.rohm.com/en/techdata_basic/transistor/soldering_condition/VML0806_Soldering_Condition.pdf, http://rohmfs.rohm.com/en/products/databook/package/spec/discrete/vml0806_tr-e.pdf) +ROHM VML0806 +0 +3 +3 +Package_SON +RTC_SMD_MicroCrystal_C3_2.5x3.7mm +MicroCrystal C3 2.5x3.7mm, https://www.microcrystal.com/fileadmin/Media/Products/RTC/Datasheet/RV-1805-C3.pdf +RTC C3 +0 +10 +10 +Package_SON +SON-8-1EP_3x2mm_P0.5mm_EP1.4x1.6mm +SON, 8 Pin (http://www.fujitsu.com/downloads/MICRO/fsa/pdf/products/memory/fram/MB85RS16-DS501-00014-6v0-E.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +SON NoLead +0 +13 +9 +Package_SON +Texas_DQK +Texas WSON-6 DQK, http://www.ti.com/lit/ds/symlink/csd16301q2.pdf +Texas WSON6 2x2mm +0 +10 +8 +Package_SON +Texas_DRC0010J +Texas DRC0010J, VSON10 3x3mm Body, 0.5mm Pitch, http://www.ti.com/lit/ds/symlink/tps63000.pdf +Texas VSON10 3x3mm +0 +17 +11 +Package_SON +Texas_DRC0010J_ThermalVias +Texas DRC0010J, VSON10 3x3mm Body, 0.5mm Pitch, http://www.ti.com/lit/ds/symlink/tps63000.pdf +Texas VSON10 3x3mm +0 +21 +11 +Package_SON +Texas_DSC0010J +3x3mm Body, 0.5mm Pitch, DSC0010J, WSON, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 DSC0010J WSON +0 +33 +11 +Package_SON +Texas_DSC0010J_ThermalVias +3x3mm Body, 0.5mm Pitch, DSC0010J, WSON, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 DSC0010J WSON +0 +39 +11 +Package_SON +Texas_PWSON-N6 +Plastic Small Outline No-Lead http://www.ti.com/lit/ml/mpds176e/mpds176e.pdf +Plastic Small Outline No-Lead +0 +7 +7 +Package_SON +Texas_R-PWSON-N12_EP0.4x2mm +http://www.ti.com/lit/ds/symlink/tpd6f003.pdf +WSON SMD +0 +16 +13 +Package_SON +Texas_S-PDSO-N12 +http://www.ti.com/lit/ds/symlink/bq27441-g1.pdf +SON thermal pads +0 +44 +13 +Package_SON +Texas_S-PVSON-N8 +8-Lead Plastic VSON, 3x3mm Body, 0.65mm Pitch, S-PVSON-N8, http://www.ti.com/lit/ds/symlink/opa2333.pdf +DFN 0.65 S-PVSON-N8 +0 +21 +9 +Package_SON +Texas_S-PVSON-N8_ThermalVias +8-Lead Plastic VSON, 3x3mm Body, 0.65mm Pitch, S-PVSON-N8, http://www.ti.com/lit/ds/symlink/opa2333.pdf +DFN 0.65 S-PVSON-N8 +0 +27 +9 +Package_SON +Texas_S-PVSON-N10 +3x3mm Body, 0.5mm Pitch, S-PVSON-N10, DRC, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 S-PVSON-N10 DRC +0 +33 +11 +Package_SON +Texas_S-PVSON-N10_ThermalVias +3x3mm Body, 0.5mm Pitch, S-PVSON-N10, DRC, http://www.ti.com/lit/ds/symlink/tps61201.pdf +0.5 S-PVSON-N10 DRC +0 +39 +11 +Package_SON +Texas_S-PWSON-N8_EP1.2x2mm +WSON, 8 Pin (http://www.ti.com/lit/ds/symlink/lp2951.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +11 +9 +Package_SON +Texas_S-PWSON-N8_EP1.2x2mm_ThermalVias +WSON, 8 Pin (http://www.ti.com/lit/ds/symlink/lp2951.pdf#page=27), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +18 +9 +Package_SON +Texas_S-PWSON-N10 +3x3mm Body, 0.5mm Pitch, S-PWSON-N10, DSC, http://www.ti.com/lit/ds/symlink/tps63060.pdf +0.5 S-PWSON-N10 DSC +0 +41 +11 +Package_SON +Texas_S-PWSON-N10_ThermalVias +3x3mm Body, 0.5mm Pitch, S-PWSON-N10, DSC, http://www.ti.com/lit/ds/symlink/tps63060.pdf +0.5 S-PWSON-N10 DSC +0 +47 +11 +Package_SON +Texas_X2SON-4_1x1mm_P0.65mm +X2SON 5 pin 1x1mm package (Reference Datasheet: http://www.ti.com/lit/ds/sbvs193d/sbvs193d.pdf Reference part: TPS383x) [StepUp generated footprint] +X2SON +0 +13 +5 +Package_SON +USON-10_2.5x1.0mm_P0.5mm +USON-10 2.5x1.0mm_ Pitch 0.5mm http://www.ti.com/lit/ds/symlink/tpd4e02b04.pdf +USON-10 2.5x1.0mm Pitch 0.5mm +0 +10 +10 +Package_SON +USON-20_2x4mm_P0.4mm +USON-20 2x4mm Pitch 0.4mm http://www.ti.com/lit/ds/symlink/txb0108.pdf +USON-20 2x4mm Pitch 0.4mm +0 +20 +20 +Package_SON +VSON-8_3.3x3.3mm_P0.65mm_NexFET +8-Lead Plastic Dual Flat, No Lead Package (MF) - 3.3x3.3x1 mm Body [VSON] http://www.ti.com/lit/ds/symlink/csd87334q3d.pdf +VSON 0.65 +0 +12 +5 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.2x2mm +VSON, 10 Pin (http://rohmfs.rohm.com/en/products/databook/datasheet/ic/power/switching_regulator/bd8314nuv-e.pdf (Page 20)), generated with kicad-footprint-generator ipc_noLead_generator.py +VSON NoLead +0 +15 +11 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.2x2mm_ThermalVias +VSON, 10 Pin (http://rohmfs.rohm.com/en/products/databook/datasheet/ic/power/switching_regulator/bd8314nuv-e.pdf (Page 20)), generated with kicad-footprint-generator ipc_noLead_generator.py +VSON NoLead +0 +18 +11 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.65x2.4mm +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm http://chip.tomsk.ru/chip/chipdoc.nsf/Package/D8A64DD165C2AAD9472579400024FC41!OpenDocument +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm +0 +21 +11 +Package_SON +VSON-10-1EP_3x3mm_P0.5mm_EP1.65x2.4mm_ThermalVias +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm http://chip.tomsk.ru/chip/chipdoc.nsf/Package/D8A64DD165C2AAD9472579400024FC41!OpenDocument +VSON 10 Thermal on 11 3x3mm Pitch 0.5mm +0 +27 +11 +Package_SON +VSONP-8-1EP_5x6_P1.27mm +SON, 8-Leads, Body 5x6x1mm, Pitch 1.27mm; (see Texas Instruments CSD18531Q5A http://www.ti.com/lit/ds/symlink/csd18531q5a.pdf) +VSONP 1.27 +0 +13 +3 +Package_SON +WSON-6-1EP_2x2mm_P0.65mm_EP1x1.6mm +WSON, 6 Pin (http://www.ti.com/lit/ds/symlink/tps61040.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +9 +7 +Package_SON +WSON-6-1EP_2x2mm_P0.65mm_EP1x1.6mm_ThermalVias +WSON, 6 Pin (http://www.ti.com/lit/ds/symlink/tps61040.pdf#page=35), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +12 +7 +Package_SON +WSON-6-1EP_3x3mm_P0.95mm +WSON6 3*3 MM, 0.95 PITCH; http://www.ti.com/lit/ds/symlink/lmr62421.pdf +WSON6 0.95 +0 +10 +7 +Package_SON +WSON-6_1.5x1.5mm_P0.5mm +WSON6, http://www.ti.com/lit/ds/symlink/tlv702.pdf +WSON6_1.5x1.5mm_P0.5mm +0 +6 +6 +Package_SON +WSON-8-1EP_2x2mm_P0.5mm_EP0.9x1.6mm +8-Lead Plastic WSON, 2x2mm Body, 0.5mm Pitch, WSON-8, http://www.ti.com/lit/ds/symlink/lm27761.pdf +WSON 8 1EP +0 +11 +9 +Package_SON +WSON-8-1EP_2x2mm_P0.5mm_EP0.9x1.6mm_ThermalVias +8-Lead Plastic WSON, 2x2mm Body, 0.5mm Pitch, WSON-8, http://www.ti.com/lit/ds/symlink/lm27761.pdf +WSON 8 1EP ThermalVias +0 +14 +9 +Package_SON +WSON-8-1EP_3x2.5mm_P0.5mm_EP1.2x1.5mm_PullBack +WSON, 8 Pin (http://www.ti.com/lit/ml/mpds400/mpds400.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +13 +9 +Package_SON +WSON-8-1EP_3x2.5mm_P0.5mm_EP1.2x1.5mm_PullBack_ThermalVias +WSON, 8 Pin (http://www.ti.com/lit/ml/mpds400/mpds400.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +18 +9 +Package_SON +WSON-8-1EP_3x3mm_P0.5mm_EP1.6x2.0mm +8-Lead Plastic WSON, 2x2mm Body, 0.5mm Pitch, WSON-8, http://www.ti.com/lit/ds/symlink/lm27761.pdf +WSON 8 1EP +0 +13 +9 +Package_SON +WSON-8-1EP_6x5mm_P1.27mm_EP3.4x4.3mm +WSON, 8 Pin (http://www.winbond.com/resource-files/w25q32jv%20revg%2003272018%20plus.pdf (page 68)), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +13 +9 +Package_SON +WSON-8-1EP_6x5mm_P1.27mm_EP3.4x4mm +WSON, 8 Pin (http://ww1.microchip.com/downloads/en/AppNotes/S72030.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +13 +9 +Package_SON +WSON-8_4x4mm_P0.8mm +http://www.ti.com/lit/ml/mpds406/mpds406.pdf +WSON8_4x4mm_P0.8mm +0 +9 +9 +Package_SON +WSON-10-1EP_2.5x2.5mm_P0.5mm_EP1.2x2mm +WSON, 10 Pin (http://www.ti.com/lit/gpn/tps63030#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +15 +11 +Package_SON +WSON-10-1EP_2.5x2.5mm_P0.5mm_EP1.2x2mm_ThermalVias +WSON, 10 Pin (http://www.ti.com/lit/gpn/tps63030#page=24), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +22 +11 +Package_SON +WSON-10-1EP_2x3mm_P0.5mm_EP0.84x2.4mm +WSON-10 package 2x3mm body, pitch 0.5mm, see http://www.ti.com/lit/ds/symlink/tps62177.pdf +WSON 0.5 +0 +14 +11 +Package_SON +WSON-10-1EP_2x3mm_P0.5mm_EP0.84x2.4mm_ThermalVias +WSON-10 package 2x3mm body, pitch 0.5mm, thermal vias and counter-pad, see http://www.ti.com/lit/ds/symlink/tps62177.pdf +WSON 0.5 thermal vias +0 +17 +11 +Package_SON +WSON-10-1EP_4x3mm_P0.5mm_EP2.2x2mm +10-Lead Plastic WSON, 4x3mm Body, 0.5mm Pitch (http://www.ti.com/lit/ds/symlink/lm4990.pdf) +WSON 0.5 +0 +15 +11 +Package_SON +WSON-12-1EP_3x2mm_P0.5mm_EP1x2.65 +WSON-12 http://www.ti.com/lit/ds/symlink/lm27762.pdf +WSON-12 +0 +15 +13 +Package_SON +WSON-12-1EP_3x2mm_P0.5mm_EP1x2.65_ThermalVias +WSON-12 http://www.ti.com/lit/ds/symlink/lm27762.pdf +WSON-12 +0 +19 +13 +Package_SON +WSON-12-1EP_4x4mm_P0.5mm_EP2.6x3mm +WSON, 12 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +17 +13 +Package_SON +WSON-12-1EP_4x4mm_P0.5mm_EP2.6x3mm_ThermalVias +WSON, 12 Pin (http://www.ti.com/lit/ds/symlink/ldc1312.pdf#page=62), generated with kicad-footprint-generator ipc_noLead_generator.py +WSON NoLead +0 +27 +13 +Package_SON +WSON-14-1EP_4.0x4.0mm_P0.5mm_EP2.6x2.6mm +14-Lead Plastic Dual Flat, No Lead Package - 4.0x4.0x0.8 mm Body [WSON], http://www.ti.com/lit/ml/mpds421/mpds421.pdf +NHL014B +0 +19 +15 +Package_SON +WSON-16_3.3x1.35_P0.4mm +WSON-16 3.3 x 1.35mm Pitch 0.4mm http://www.chip.tomsk.ru/chip/chipdoc.nsf/Package/C67E729A4D6C883A4725793E004C8739!OpenDocument +WSON-16 3.3 x 1.35mm Pitch 0.4mm +0 +20 +17 +Package_SON +X2SON-8_1.4x1mm_P0.35mm +X2SON-8 1.4x1mm Pitch0.35mm http://www.ti.com/lit/ds/symlink/pca9306.pdf +X2SON-8 1.4x1mm Pitch0.35mm +0 +8 +8 +Package_SO_J-Lead +TSOC-6_3.76x3.94mm_P1.27mm +Maxim Integrated TSOC-6 D6+1,https://datasheets.maximintegrated.com/en/ds/DS2401.pdf, https://pdfserv.maximintegrated.com/land_patterns/90-0321.PDF +TSOC-6 +0 +6 +6 +Package_TO_SOT_SMD +ATPAK-2 +ATPAK SMD package, http://www.onsemi.com/pub/Collateral/ENA2192-D.PDF +ATPAK +0 +7 +3 +Package_TO_SOT_SMD +Analog_KS-4 +Analog Devices KS-4, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/sc70ks/ks_4.pdf +Analog Devices KS-4 (like EIAJ SC-82) +0 +4 +4 +Package_TO_SOT_SMD +Diodes_SOT-553 +Diodes SOT-553, https://www.diodes.com/assets/Package-Files/SOT553.pdf +SOT-553 +0 +5 +5 +Package_TO_SOT_SMD +HVSOF5 +HVSOF5, http://rohmfs.rohm.com/en/techdata_basic/ic/package/hvsof5_1-e.pdf, http://rohmfs.rohm.com/en/products/databook/datasheet/ic/sensor/hall/bu52001gul-e.pdf +HVSOF5 +0 +5 +5 +Package_TO_SOT_SMD +HVSOF6 +HVSOF6, http://rohmfs.rohm.com/en/techdata_basic/ic/package/hvsof6_1-e.pdf, http://rohmfs.rohm.com/en/products/databook/datasheet/ic/audio_video/video_amplifier/bh76106hfv-e.pdf +HVSOF6 +0 +7 +7 +Package_TO_SOT_SMD +Infineon_PG-HDSOP-10-1 +Infineon PG-HDSOP-10-1 (DDPAK), 20.96x6.5x2.3mm, slug up (https://www.infineon.com/cms/en/product/packages/PG-HDSOP/PG-HDSOP-10-1/) +hdsop 10 ddpak +0 +10 +10 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-1 +HSOF-8-1 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-1/) +mosfet hsof toll +0 +53 +3 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-1_ThermalVias +HSOF-8-1 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-1/) +mosfet hsof toll thermal vias +0 +96 +3 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-2 +HSOF-8-2 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-2/) +mosfet hsof toll +0 +12 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-2_ThermalVias +HSOF-8-2 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-2/) +mosfet hsof toll thermal vias +0 +97 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-2_ThermalVias2 +HSOF-8-2 [TOLL] power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-2/, https://www.infineon.com/dgdl/Infineon-ApplicationNote_600V_CoolMOS_C7_Gold_TOLL-AN-v01_00-EN.pdf?fileId=5546d4625b10283a015b144a1af70df6) +mosfet hsof toll thermal vias +0 +159 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-3 +HSOF-8-3 power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-3/) +mosfet hsof +0 +25 +4 +Package_TO_SOT_SMD +Infineon_PG-HSOF-8-3_ThermalVias +HSOF-8-3 power MOSFET (http://www.infineon.com/cms/en/product/packages/PG-HSOF/PG-HSOF-8-3/) +mosfet hsof +0 +64 +4 +Package_TO_SOT_SMD +Infineon_PG-TO-220-7Lead_TabPin8 +Infineon PG-TO-220-7, Tab as Pin 8, see e.g. https://www.infineon.com/dgdl/Infineon-BTS50055-1TMC-DS-v01_00-EN.pdf?fileId=5546d4625a888733015aa9b0007235e9 +Infineon PG-TO-220-7 +0 +12 +8 +Package_TO_SOT_SMD +LFPAK33 +LFPAK33 SOT-1210 https://assets.nexperia.com/documents/outline-drawing/SOT1210.pdf +LFPAK33 SOT-1210 +0 +17 +5 +Package_TO_SOT_SMD +LFPAK56 +LFPAK56 https://assets.nexperia.com/documents/outline-drawing/SOT669.pdf +LFPAK56 SOT-669 Power-SO8 +0 +18 +5 +Package_TO_SOT_SMD +OnSemi_ECH8 +On Semiconductor ECH8, https://www.onsemi.com/pub/Collateral/318BF.PDF +ECH8 SOT28-FL SOT-28-FL +0 +8 +8 +Package_TO_SOT_SMD +PQFN_8x8 +Low Profile 8x8mm PQFN, Dual Cool 88, https://www.onsemi.com/pub/Collateral/FDMT80080DC-D.pdf +pqfn vdfn mosfet +0 +9 +3 +Package_TO_SOT_SMD +PowerMacro_M234_NoHole +TO-50-4 Power Macro Package Style M234 +TO-50-4 Power Macro Package Style M234 +0 +4 +4 +Package_TO_SOT_SMD +PowerMacro_M234_WithHole +TO-50-4 Power Macro Package Style M234 +TO-50-4 Power Macro Package Style M234 +0 +4 +4 +Package_TO_SOT_SMD +Rohm_HRP7 +Rohm HRP7 SMD package, http://rohmfs.rohm.com/en/techdata_basic/ic/package/hrp7_1-e.pdf, http://rohmfs.rohm.com/en/products/databook/datasheet/ic/motor/dc/bd621x-e.pdf +Rohm HRP7 SMD +0 +69 +7 +Package_TO_SOT_SMD +SC-59 +SC-59, https://lib.chipdip.ru/images/import_diod/original/SOT-23_SC-59.jpg +SC-59 +0 +3 +3 +Package_TO_SOT_SMD +SC-59_Handsoldering +SC-59, hand-soldering varaint, https://lib.chipdip.ru/images/import_diod/original/SOT-23_SC-59.jpg +SC-59 hand-soldering +0 +3 +3 +Package_TO_SOT_SMD +SC-70-8 +SC70-8 +SC70-8 +0 +8 +8 +Package_TO_SOT_SMD +SC-70-8_Handsoldering +SC70-8, Handsoldering +SC70-8 Handsoldering +0 +8 +8 +Package_TO_SOT_SMD +SC-82AA +SC-82AA +SC-82AA +0 +4 +4 +Package_TO_SOT_SMD +SC-82AA_Handsoldering +SC-82AA +SC-82AA +0 +4 +4 +Package_TO_SOT_SMD +SC-82AB +SC-82AB +SC-82AB +0 +4 +4 +Package_TO_SOT_SMD +SC-82AB_Handsoldering +SC-82AB +SC-82AB +0 +4 +4 +Package_TO_SOT_SMD +SOT-23 +SOT-23, Standard +SOT-23 +0 +3 +3 +Package_TO_SOT_SMD +SOT-23-5 +5-pin SOT23 package +SOT-23-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-23-5_HandSoldering +5-pin SOT23 package +SOT-23-5 hand-soldering +0 +5 +5 +Package_TO_SOT_SMD +SOT-23-6 +6-pin SOT-23 package +SOT-23-6 +0 +6 +6 +Package_TO_SOT_SMD +SOT-23-6_Handsoldering +6-pin SOT-23 package, Handsoldering +SOT-23-6 Handsoldering +0 +6 +6 +Package_TO_SOT_SMD +SOT-23-8 +8-pin SOT-23 package, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/sot-23rj/rj_8.pdf +SOT-23-8 +0 +8 +8 +Package_TO_SOT_SMD +SOT-23-8_Handsoldering +8-pin SOT-23 package, Handsoldering, http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/sot-23rj/rj_8.pdf +SOT-23-8 Handsoldering +0 +8 +8 +Package_TO_SOT_SMD +SOT-23W +SOT-23W http://www.allegromicro.com/~/media/Files/Datasheets/A112x-Datasheet.ashx?la=en&hash=7BC461E058CC246E0BAB62433B2F1ECA104CA9D3 +SOT-23W +0 +3 +3 +Package_TO_SOT_SMD +SOT-23W_Handsoldering +SOT-23W http://www.allegromicro.com/~/media/Files/Datasheets/A112x-Datasheet.ashx?la=en&hash=7BC461E058CC246E0BAB62433B2F1ECA104CA9D3 +SOT-23W for handsoldering +0 +3 +3 +Package_TO_SOT_SMD +SOT-23_Handsoldering +SOT-23, Handsoldering +SOT-23 +0 +3 +3 +Package_TO_SOT_SMD +SOT-89-3 +SOT-89-3, http://ww1.microchip.com/downloads/en/DeviceDoc/3L_SOT-89_MB_C04-029C.pdf +SOT-89-3 +0 +3 +3 +Package_TO_SOT_SMD +SOT-89-3_Handsoldering +SOT-89-3 Handsoldering +SOT-89-3 Handsoldering +0 +3 +3 +Package_TO_SOT_SMD +SOT-89-5 +SOT-89-5, http://www.e-devices.ricoh.co.jp/en/products/product_power/pkg/sot-89-5.pdf +SOT-89-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-89-5_Handsoldering +SOT-89-5, http://www.e-devices.ricoh.co.jp/en/products/product_power/pkg/sot-89-5.pdf +SOT-89-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-143 +SOT-143 +SOT-143 +0 +4 +4 +Package_TO_SOT_SMD +SOT-143R_Reverse +SOT-143R Reverse +SOT-143R Reverse +0 +4 +4 +Package_TO_SOT_SMD +SOT-143R_Reverse_Handsoldering +SOT-143R Reverse Handsoldering +SOT-143 Reverse Handsoldering +0 +4 +4 +Package_TO_SOT_SMD +SOT-143_Handsoldering +SOT-143 Handsoldering +SOT-143 Handsoldering +0 +4 +4 +Package_TO_SOT_SMD +SOT-223 +module CMS SOT223 4 pins +CMS SOT +0 +4 +4 +Package_TO_SOT_SMD +SOT-223-3_TabPin2 +module CMS SOT223 4 pins +CMS SOT +0 +4 +3 +Package_TO_SOT_SMD +SOT-223-5 +module CMS SOT223 5 pins, http://ww1.microchip.com/downloads/en/DeviceDoc/51751a.pdf +CMS SOT +0 +5 +5 +Package_TO_SOT_SMD +SOT-223-6 +module CMS SOT223 6 pins, http://www.ti.com/lit/ds/symlink/tps737.pdf +CMS SOT +0 +6 +6 +Package_TO_SOT_SMD +SOT-223-6_TabPin3 +module CMS SOT223 6 pins, http://www.ti.com/lit/ds/symlink/tps737.pdf +CMS SOT +0 +6 +5 +Package_TO_SOT_SMD +SOT-223-8 +module CMS SOT223 8 pins, https://www.diodes.com/assets/Datasheets/ZXSBMR16PT8.pdf +CMS SOT +0 +8 +8 +Package_TO_SOT_SMD +SOT-323_SC-70 +SOT-323, SC-70 +SOT-323 SC-70 +0 +3 +3 +Package_TO_SOT_SMD +SOT-323_SC-70_Handsoldering +SOT-323, SC-70 Handsoldering +SOT-323 SC-70 Handsoldering +0 +3 +3 +Package_TO_SOT_SMD +SOT-343_SC-70-4 +SOT-343, SC-70-4 +SOT-343 SC-70-4 +0 +4 +4 +Package_TO_SOT_SMD +SOT-343_SC-70-4_Handsoldering +SOT-343, SC-70-4, Handsoldering +SOT-343 SC-70-4 Handsoldering +0 +4 +4 +Package_TO_SOT_SMD +SOT-353_SC-70-5 +SOT-353, SC-70-5 +SOT-353 SC-70-5 +0 +5 +5 +Package_TO_SOT_SMD +SOT-353_SC-70-5_Handsoldering +SOT-353, SC-70-5, Handsoldering +SOT-353 SC-70-5 Handsoldering +0 +5 +5 +Package_TO_SOT_SMD +SOT-363_SC-70-6 +SOT-363, SC-70-6 +SOT-363 SC-70-6 +0 +6 +6 +Package_TO_SOT_SMD +SOT-363_SC-70-6_Handsoldering +SOT-363, SC-70-6, Handsoldering +SOT-363 SC-70-6 Handsoldering +0 +6 +6 +Package_TO_SOT_SMD +SOT-383F +8-pin SOT-383F, http://www.mouser.com/ds/2/80/CPDVR085V0C-HF-RevB-10783.pdf +SOT-383F +0 +9 +9 +Package_TO_SOT_SMD +SOT-383FL +8-pin SOT-383FL package, http://www.onsemi.com/pub_link/Collateral/ENA2267-D.PDF +SOT-383FL +0 +8 +8 +Package_TO_SOT_SMD +SOT-416 +SOT-416, https://www.nxp.com/docs/en/package-information/SOT416.pdf +SOT-416 +0 +3 +3 +Package_TO_SOT_SMD +SOT-523 +SOT523, https://www.diodes.com/assets/Package-Files/SOT523.pdf +SOT-523 +0 +3 +3 +Package_TO_SOT_SMD +SOT-543 +SOT-543 4 lead surface package +SOT-543 SC-107A EMD4 +0 +4 +4 +Package_TO_SOT_SMD +SOT-553 +SOT553 +SOT-553 +0 +5 +5 +Package_TO_SOT_SMD +SOT-563 +SOT563 +SOT-563 +0 +6 +6 +Package_TO_SOT_SMD +SOT-665 +SOT665 +SOT-665 +0 +5 +5 +Package_TO_SOT_SMD +SOT-666 +SOT666 +SOT-666 +0 +6 +6 +Package_TO_SOT_SMD +SOT-723 +http://toshiba.semicon-storage.com/info/docget.jsp?did=5879&prodName=RN1104MFV +sot 723 +0 +3 +3 +Package_TO_SOT_SMD +SOT-883 +SOT-883, https://assets.nexperia.com/documents/outline-drawing/SOT883.pdf +SOT-883 +0 +3 +3 +Package_TO_SOT_SMD +SOT-886 +SOT-886 +SOT-886 +0 +6 +6 +Package_TO_SOT_SMD +SOT-963 +SOT 963 6 pins package 1x0.8mm pitch 0.35mm +SOT 963 6 pins package 1x0.8mm pitch 0.35mm +0 +6 +6 +Package_TO_SOT_SMD +SOT-1123 +SOT-1123 small outline transistor (see http://www.onsemi.com/pub/Collateral/NST3906F3-D.PDF) +SOT-1123 transistor +0 +3 +3 +Package_TO_SOT_SMD +SOT-1333-1 +SOT-1333-1 +SOT-1333-1 +0 +9 +9 +Package_TO_SOT_SMD +SOT-1334-1 +SOT-1334-1 +SOT-1334-1 +0 +14 +14 +Package_TO_SOT_SMD +SuperSOT-3 +3-pin SuperSOT package https://www.fairchildsemi.com/package-drawings/MA/MA03B.pdf +SuperSOT-3 SSOT-3 +0 +3 +3 +Package_TO_SOT_SMD +SuperSOT-6 +6-pin SuperSOT package http://www.mouser.com/ds/2/149/FMB5551-889214.pdf +SuperSOT-6 SSOT-6 +0 +6 +6 +Package_TO_SOT_SMD +SuperSOT-8 +8-pin SuperSOT package, http://www.icbank.com/icbank_data/semi_package/ssot8_dim.pdf +SuperSOT-8 SSOT-8 +0 +8 +8 +Package_TO_SOT_SMD +TDSON-8-1 +Power MOSFET package, TDSON-8-1, 5.15x5.9mm (https://www.infineon.com/cms/en/product/packages/PG-TDSON/PG-TDSON-8-1/) +tdson +0 +14 +5 +Package_TO_SOT_SMD +TO-50-3_LongPad-NoHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-3_LongPad-WithHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-3_ShortPad-NoHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-3_ShortPad-WithHole_Housing +TO-50-3 Macro T Package Style M236 +TO-50-3 Macro T Package Style M236 +0 +3 +3 +Package_TO_SOT_SMD +TO-50-4_LongPad-NoHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-50-4_LongPad-WithHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-50-4_ShortPad-NoHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-50-4_ShortPad-WithHole_Housing +TO-50-4 Macro X Package Style M238 +TO-50-4 Macro X Package Style M238 +0 +4 +4 +Package_TO_SOT_SMD +TO-252-2 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-3-1/ +DPAK TO-252 DPAK-3 TO-252-3 SOT-428 +0 +7 +3 +Package_TO_SOT_SMD +TO-252-2_TabPin1 +TO-252-2, tab to pin 1 https://www.wolfspeed.com/media/downloads/87/CSD01060.pdf +TO-252-2 diode +0 +7 +2 +Package_TO_SOT_SMD +TO-252-3_TabPin2 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-3-1/ +DPAK TO-252 DPAK-3 TO-252-3 SOT-428 +0 +8 +3 +Package_TO_SOT_SMD +TO-252-3_TabPin4 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-3-1/ +DPAK TO-252 DPAK-3 TO-252-3 SOT-428 +0 +8 +4 +Package_TO_SOT_SMD +TO-252-4 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-5-11/ +DPAK TO-252 DPAK-5 TO-252-5 +0 +9 +5 +Package_TO_SOT_SMD +TO-252-5_TabPin3 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-5-11/ +DPAK TO-252 DPAK-5 TO-252-5 +0 +10 +5 +Package_TO_SOT_SMD +TO-252-5_TabPin6 +TO-252 / DPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO252/PG-TO252-5-11/ +DPAK TO-252 DPAK-5 TO-252-5 +0 +10 +6 +Package_TO_SOT_SMD +TO-263-2 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-3-1/ +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 +0 +7 +3 +Package_TO_SOT_SMD +TO-263-2_TabPin1 +TO-263 / D2PAK / DDPAK SMD package, tab to pin 1, https://www.wolfspeed.com/media/downloads/137/C3D06060G.pdf +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 diode +0 +7 +2 +Package_TO_SOT_SMD +TO-263-3_TabPin2 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-3-1/ +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 +0 +8 +3 +Package_TO_SOT_SMD +TO-263-3_TabPin4 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-3-1/ +D2PAK DDPAK TO-263 D2PAK-3 TO-263-3 SOT-404 +0 +8 +4 +Package_TO_SOT_SMD +TO-263-4 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-5-1/ +D2PAK DDPAK TO-263 D2PAK-5 TO-263-5 SOT-426 +0 +9 +5 +Package_TO_SOT_SMD +TO-263-5_TabPin3 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-5-1/ +D2PAK DDPAK TO-263 D2PAK-5 TO-263-5 SOT-426 +0 +10 +5 +Package_TO_SOT_SMD +TO-263-5_TabPin6 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-5-1/ +D2PAK DDPAK TO-263 D2PAK-5 TO-263-5 SOT-426 +0 +10 +6 +Package_TO_SOT_SMD +TO-263-6 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-7-1/ +D2PAK DDPAK TO-263 D2PAK-7 TO-263-7 SOT-427 +0 +11 +7 +Package_TO_SOT_SMD +TO-263-7_TabPin4 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-7-1/ +D2PAK DDPAK TO-263 D2PAK-7 TO-263-7 SOT-427 +0 +12 +7 +Package_TO_SOT_SMD +TO-263-7_TabPin8 +TO-263 / D2PAK / DDPAK SMD package, http://www.infineon.com/cms/en/product/packages/PG-TO263/PG-TO263-7-1/ +D2PAK DDPAK TO-263 D2PAK-7 TO-263-7 SOT-427 +0 +12 +8 +Package_TO_SOT_SMD +TO-263-9_TabPin5 +TO-263 / D2PAK / DDPAK SMD package, http://www.ti.com/lit/ds/symlink/lm4755.pdf +D2PAK DDPAK TO-263 D2PAK-9 TO-263-9 +0 +14 +9 +Package_TO_SOT_SMD +TO-263-9_TabPin10 +TO-263 / D2PAK / DDPAK SMD package, http://www.ti.com/lit/ds/symlink/lm4755.pdf +D2PAK DDPAK TO-263 D2PAK-9 TO-263-9 +0 +14 +10 +Package_TO_SOT_SMD +TO-268-2 +TO-268/D3PAK SMD package, http://www.icbank.com/icbank_data/semi_package/to268aa_dim.pdf +D3PAK TO-268 D3PAK-3 TO-268-3 +0 +7 +3 +Package_TO_SOT_SMD +TO-269AA +SMD package TO-269AA (e.g. diode bridge), see http://www.vishay.com/docs/88854/padlayouts.pdf +TO-269AA MBS diode bridge +0 +4 +4 +Package_TO_SOT_SMD +TO-277A +Thermal enhanced ultra thin SMD package; 3 leads; body: 4.3x6.1x0.43mm, https://www.vishay.com/docs/95570/to-277asmpc.pdf +TO-277A SMPC +0 +12 +3 +Package_TO_SOT_SMD +TO-277B +TO-227B https://media.digikey.com/pdf/Data%20Sheets/Littelfuse%20PDFs/DST2050S.pdf +TO-277B +0 +9 +3 +Package_TO_SOT_SMD +TSOT-23 +3-pin TSOT23 package, http://www.analog.com.tw/pdf/All_In_One.pdf +TSOT-23 +0 +3 +3 +Package_TO_SOT_SMD +TSOT-23-5 +5-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_5_05-08-1635.pdf +TSOT-23-5 +0 +5 +5 +Package_TO_SOT_SMD +TSOT-23-5_HandSoldering +5-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_5_05-08-1635.pdf +TSOT-23-5 Hand-soldering +0 +5 +5 +Package_TO_SOT_SMD +TSOT-23-6 +6-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_6_05-08-1636.pdf +TSOT-23-6 MK06A TSOT-6 +0 +6 +6 +Package_TO_SOT_SMD +TSOT-23-6_HandSoldering +6-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_6_05-08-1636.pdf +TSOT-23-6 MK06A TSOT-6 Hand-soldering +0 +6 +6 +Package_TO_SOT_SMD +TSOT-23-8 +8-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_8_05-08-1637.pdf +TSOT-23-8 +0 +8 +8 +Package_TO_SOT_SMD +TSOT-23-8_HandSoldering +8-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_8_05-08-1637.pdf +TSOT-23-8 Hand-soldering +0 +8 +8 +Package_TO_SOT_SMD +TSOT-23_HandSoldering +5-pin TSOT23 package, http://cds.linear.com/docs/en/packaging/SOT_5_05-08-1635.pdf +TSOT-23 Hand-soldering +0 +3 +3 +Package_TO_SOT_SMD +Texas_DRT-3 +Texas Instrument DRT-3 1x0.8mm Pitch 0.7mm http://www.ti.com/lit/ds/symlink/tpd2eusb30.pdf +DRT-3 1x0.8mm Pitch 0.7mm +0 +3 +3 +Package_TO_SOT_SMD +Texas_NDQ +Texas Instruments, NDQ, 5 pin (https://www.ti.com/lit/ml/mmsf022/mmsf022.pdf) +ti pfm dap +0 +6 +6 +Package_TO_SOT_SMD +Texas_NDY0011A +TO-PMOD-11 11-pin switching regulator package, http://www.ti.com/lit/ml/mmsf025/mmsf025.pdf +Texas TO-PMOD NDY00011A +0 +12 +12 +Package_TO_SOT_SMD +Texas_R-PDSO-G6 +R-PDSO-G6, http://www.ti.com/lit/ds/slis144b/slis144b.pdf +R-PDSO-G6 SC-70-6 +0 +6 +6 +Package_TO_SOT_SMD +VSOF5 +VSOF5 +VSOF5 +0 +5 +5 +Package_TO_SOT_SMD +Vishay_PowerPAK_SC70-6L_Dual +Vishay PowerPAK SC70 dual transistor package http://www.vishay.com/docs/70487/70487.pdf +powerpak sc70 sc-70 dual +0 +8 +6 +Package_TO_SOT_SMD +Vishay_PowerPAK_SC70-6L_Single +Vishay PowerPAK SC70 single transistor package http://www.vishay.com/docs/70486/70486.pdf +powerpak sc70 sc-70 +0 +6 +3 +Package_TO_SOT_THT +Fairchild_TO-220F-6L +Fairchild TO-220F-6L, http://www.mouser.com/ds/2/149/FSL136MRT-113334.pdf +Fairchild TO-220F-6L +0 +6 +6 +Package_TO_SOT_THT +Heraeus_TO-92-2 +TO-92 2-pin variant by Heraeus, drill 0.75mm (http://www.produktinfo.conrad.com/datenblaetter/175000-199999/181293-da-01-de-TO92_Temperatursensor_PT1000_32209225.pdf) +to-92 +0 +2 +2 +Package_TO_SOT_THT +NEC_Molded_7x4x9mm +Molded Japan Transistor Package 7x4x9mm^3, http://rtellason.com/transdata/2sb734.pdf +Japan transistor +0 +3 +3 +Package_TO_SOT_THT +PowerIntegrations_TO-220-7C +Non Isolated Modified TO-220 7pin Package, see http://www.farnell.com/datasheets/5793.pdf +Power Integration Y Package +0 +6 +6 +Package_TO_SOT_THT +SIPAK-1EP_Horizontal_TabDown +SIPAK, Horizontal, RM 2.286mm +SIPAK Horizontal RM 2.286mm +0 +4 +4 +Package_TO_SOT_THT +SIPAK_Vertical +SIPAK, Vertical, RM 2.286mm +SIPAK Vertical RM 2.286mm +0 +3 +3 +Package_TO_SOT_THT +SOD-70_P2.54mm +Plastic near cylindrical package Sod-70 see: https://www.nxp.com/docs/en/data-sheet/KTY81_SER.pdf [StepUp generated footprint] +Sod-70 +0 +2 +2 +Package_TO_SOT_THT +SOD-70_P5.08mm +Plastic near cylindrical package Sod-70 see: https://www.nxp.com/docs/en/data-sheet/KTY81_SER.pdf [StepUp generated footprint] +Sod-70 +0 +2 +2 +Package_TO_SOT_THT +SOT-227 +SOT-227 / SOT-227B / ISOTOP, M4 mounting screws (https://www.vishay.com/docs/95423/sot227g2.pdf, https://www.vishay.com/docs/95793/vs-fc420sa10.pdf) +sot 227 isotop +0 +8 +4 +Package_TO_SOT_THT +TO-3 +Transistor TO-3 +TR TO-3 TO3 TO-204 +0 +4 +3 +Package_TO_SOT_THT +TO-3P-3_Horizontal_TabDown +TO-3P-3, Horizontal, RM 5.45mm, , see https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.TO-3P(N).html +TO-3P-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3P-3_Horizontal_TabUp +TO-3P-3, Horizontal, RM 5.45mm, , see https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.TO-3P(N).html +TO-3P-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3P-3_Vertical +TO-3P-3, Vertical, RM 5.45mm, , see https://toshiba.semicon-storage.com/ap-en/design-support/package/detail.TO-3P(N).html +TO-3P-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3PB-3_Horizontal_TabDown +TO-3PB-3, Horizontal, RM 5.45mm, , see http://www.onsemi.com/pub/Collateral/340AC.PDF +TO-3PB-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3PB-3_Horizontal_TabUp +TO-3PB-3, Horizontal, RM 5.45mm, , see http://www.onsemi.com/pub/Collateral/340AC.PDF +TO-3PB-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-3PB-3_Vertical +TO-3PB-3, Vertical, RM 5.45mm, , see http://www.onsemi.com/pub/Collateral/340AC.PDF +TO-3PB-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-5-2 +TO-5-2 +TO-5-2 +0 +2 +2 +Package_TO_SOT_THT +TO-5-2_Window +TO-5-2_Window, Window +TO-5-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-5-3 +TO-5-3 +TO-5-3 +0 +3 +3 +Package_TO_SOT_THT +TO-5-3_Window +TO-5-3_Window, Window +TO-5-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-5-4 +TO-5-4 +TO-5-4 +0 +4 +4 +Package_TO_SOT_THT +TO-5-4_Window +TO-5-4_Window, Window +TO-5-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-5-6 +TO-5-6 +TO-5-6 +0 +6 +6 +Package_TO_SOT_THT +TO-5-6_Window +TO-5-6_Window, Window +TO-5-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-5-8 +TO-5-8 +TO-5-8 +0 +8 +8 +Package_TO_SOT_THT +TO-5-8_PD5.08 +TO-5-8_PD5.08 +TO-5-8_PD5.08 +0 +8 +8 +Package_TO_SOT_THT +TO-5-8_PD5.08_Window +TO-5-8_PD5.08_Window, Window +TO-5-8_PD5.08_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-5-8_Window +TO-5-8_Window, Window +TO-5-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-5-10 +TO-5-10 +TO-5-10 +0 +10 +10 +Package_TO_SOT_THT +TO-5-10_Window +TO-5-10_Window, Window +TO-5-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-8-2 +TO-8-2 +TO-8-2 +0 +2 +2 +Package_TO_SOT_THT +TO-8-2_Window +TO-8-2_Window, Window +TO-8-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-8-3 +TO-8-3 +TO-8-3 +0 +3 +3 +Package_TO_SOT_THT +TO-8-3_Window +TO-8-3_Window, Window +TO-8-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-11-2 +TO-11-2 +TO-11-2 +0 +2 +2 +Package_TO_SOT_THT +TO-11-2_Window +TO-11-2_Window, Window +TO-11-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-11-3 +TO-11-3 +TO-11-3 +0 +3 +3 +Package_TO_SOT_THT +TO-11-3_Window +TO-11-3_Window, Window +TO-11-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-12-4 +TO-12-4 +TO-12-4 +0 +4 +4 +Package_TO_SOT_THT +TO-12-4_Window +TO-12-4_Window, Window +TO-12-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-17-4 +TO-17-4 +TO-17-4 +0 +4 +4 +Package_TO_SOT_THT +TO-17-4_Window +TO-17-4_Window, Window +TO-17-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-18-2 +TO-18-2 +TO-18-2 +0 +2 +2 +Package_TO_SOT_THT +TO-18-2_Lens +TO-18-2_Lens, Lens +TO-18-2_Lens Lens +0 +2 +2 +Package_TO_SOT_THT +TO-18-2_Window +TO-18-2_Window, Window +TO-18-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-18-3 +TO-18-3 +TO-18-3 +0 +3 +3 +Package_TO_SOT_THT +TO-18-3_Lens +TO-18-3_Lens, Lens +TO-18-3_Lens Lens +0 +3 +3 +Package_TO_SOT_THT +TO-18-3_Window +TO-18-3_Window, Window +TO-18-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-18-4 +TO-18-4 +TO-18-4 +0 +4 +4 +Package_TO_SOT_THT +TO-18-4_Lens +TO-18-4_Lens, Lens +TO-18-4_Lens Lens +0 +4 +4 +Package_TO_SOT_THT +TO-18-4_Window +TO-18-4_Window, Window +TO-18-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-33-4 +TO-33-4 +TO-33-4 +0 +4 +4 +Package_TO_SOT_THT +TO-33-4_Window +TO-33-4_Window, Window +TO-33-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-38-2 +TO-38-2 +TO-38-2 +0 +2 +2 +Package_TO_SOT_THT +TO-38-2_Window +TO-38-2_Window, Window +TO-38-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-38-3 +TO-38-3 +TO-38-3 +0 +3 +3 +Package_TO_SOT_THT +TO-38-3_Window +TO-38-3_Window, Window +TO-38-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-39-2 +TO-39-2 +TO-39-2 +0 +2 +2 +Package_TO_SOT_THT +TO-39-2_Window +TO-39-2_Window, Window +TO-39-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-39-3 +TO-39-3 +TO-39-3 +0 +3 +3 +Package_TO_SOT_THT +TO-39-3_Window +TO-39-3_Window, Window +TO-39-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-39-4 +TO-39-4 +TO-39-4 +0 +4 +4 +Package_TO_SOT_THT +TO-39-4_Window +TO-39-4_Window, Window +TO-39-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-39-6 +TO-39-6 +TO-39-6 +0 +6 +6 +Package_TO_SOT_THT +TO-39-6_Window +TO-39-6_Window, Window +TO-39-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-39-8 +TO-39-8 +TO-39-8 +0 +8 +8 +Package_TO_SOT_THT +TO-39-8_Window +TO-39-8_Window, Window +TO-39-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-39-10 +TO-39-10 +TO-39-10 +0 +10 +10 +Package_TO_SOT_THT +TO-39-10_Window +TO-39-10_Window, Window +TO-39-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-46-2 +TO-46-2 +TO-46-2 +0 +2 +2 +Package_TO_SOT_THT +TO-46-2_Pin2Center +TO-46-2, Pin2 at center of package, Thorlabs photodiodes +TO-46-2 Thorlabs +0 +2 +2 +Package_TO_SOT_THT +TO-46-2_Pin2Center_Window +TO-46-2, Pin2 at center of package, Thorlabs photodiodes +TO-46-2 Thorlabs +0 +2 +2 +Package_TO_SOT_THT +TO-46-2_Window +TO-46-2_Window, Window +TO-46-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-46-3 +TO-46-3 +TO-46-3 +0 +3 +3 +Package_TO_SOT_THT +TO-46-3_Pin2Center +TO-46-3, Pin2 at center of package, Thorlabs photodiodes, https://www.thorlabs.de/drawings/374b6862eb3b5a04-9360B5F6-5056-2306-D912111C06C3F830/FDGA05-SpecSheet.pdf +TO-46-3 Thorlabs +0 +3 +3 +Package_TO_SOT_THT +TO-46-3_Pin2Center_Window +TO-46-3, Pin2 at center of package, Thorlabs photodiodes, https://www.thorlabs.de/drawings/374b6862eb3b5a04-9360B5F6-5056-2306-D912111C06C3F830/FDGA05-SpecSheet.pdf +TO-46-3 Thorlabs +0 +3 +3 +Package_TO_SOT_THT +TO-46-3_Window +TO-46-3_Window, Window +TO-46-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-46-4 +TO-46-4 +TO-46-4 +0 +4 +4 +Package_TO_SOT_THT +TO-46-4_Window +TO-46-4_Window, Window +TO-46-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-52-2 +TO-52-2 +TO-52-2 +0 +2 +2 +Package_TO_SOT_THT +TO-52-2_Window +TO-52-2_Window, Window +TO-52-2_Window Window +0 +2 +2 +Package_TO_SOT_THT +TO-52-3 +TO-52-3 +TO-52-3 +0 +3 +3 +Package_TO_SOT_THT +TO-52-3_Window +TO-52-3_Window, Window +TO-52-3_Window Window +0 +3 +3 +Package_TO_SOT_THT +TO-72-4 +TO-72-4 +TO-72-4 +0 +4 +4 +Package_TO_SOT_THT +TO-72-4_Window +TO-72-4_Window, Window +TO-72-4_Window Window +0 +4 +4 +Package_TO_SOT_THT +TO-75-6 +TO-75-6 +TO-75-6 +0 +6 +6 +Package_TO_SOT_THT +TO-75-6_Window +TO-75-6_Window, Window +TO-75-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-78-6 +TO-78-6 +TO-78-6 +0 +6 +6 +Package_TO_SOT_THT +TO-78-6_Window +TO-78-6_Window, Window +TO-78-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-78-8 +TO-78-8 +TO-78-8 +0 +8 +8 +Package_TO_SOT_THT +TO-78-8_Window +TO-78-8_Window, Window +TO-78-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-78-10 +TO-78-10 +TO-78-10 +0 +10 +10 +Package_TO_SOT_THT +TO-78-10_Window +TO-78-10_Window, Window +TO-78-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-92 +TO-92 leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92-2 +TO-92 2-pin leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 diode SOD70 +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_Horizontal1 +2-pin TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 temperature sensor diode +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_Horizontal2 +2-pin TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 temperature sensor diode +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_W4.0mm_Horizontal_FlatSideDown +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_W4.0mm_Horizontal_FlatSideUp +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92-2_Wide +TO-92 2-pin leads in-line, wide, drill 0.75mm +to-92 sc-43 sc-43a sot54 PA33 diode SOD70 +0 +2 +2 +Package_TO_SOT_THT +TO-92Flat +TO-92Flat package, often used for hall sensors, drill 0.75mm (see e.g. http://www.ti.com/lit/ds/symlink/drv5023.pdf) +to-92Flat hall sensor +0 +3 +3 +Package_TO_SOT_THT +TO-92L +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Molded Narrow transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_HandSolder +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm, hand-soldering variant with enlarged pads (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_Inline +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Inline Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_Inline_Wide +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Inline Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92L_Wide +TO-92L leads in-line (large body variant of TO-92), also known as TO-226, wide, drill 0.75mm (see https://www.diodes.com/assets/Package-Files/TO92L.pdf and http://www.ti.com/lit/an/snoa059/snoa059.pdf) +TO-92L Molded Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92Mini-2 +TO-92Mini package, drill 0.6mm (https://media.digikey.com/pdf/Data%20Sheets/Infineon%20PDFs/KT,KTY.pdf) +to-92Mini transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92S +TO-92S package, drill 0.75mm (https://www.diodes.com/assets/Package-Files/TO92S%20(Type%20B).pdf) +to-92S transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92S-2 +TO-92S package, 2-pin, drill 0.75mm (https://www.diodes.com/assets/Package-Files/TO92S%20(Type%20B).pdf) +to-92S transistor +0 +2 +2 +Package_TO_SOT_THT +TO-92S_Wide +TO-92S_Wide package, drill 0.75mm (https://www.diodes.com/assets/Package-Files/TO92S%20(Type%20B).pdf) +TO-92S_Wide transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_HandSolder +TO-92 leads molded, narrow, drill 0.75mm, handsoldering variant with enlarged pads (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Horizontal1 +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Horizontal2 +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline +TO-92 leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_Horizontal1 +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_Horizontal2 +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_W4.0mm_Horizontal_FlatSideDown +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_W4.0mm_Horizontal_FlatSideUp +TO-92 horizontal, leads in-line, narrow, oval pads, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Inline_Wide +TO-92 leads in-line, wide, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_W4.0mm_StaggerEven_Horizontal_FlatSideDown +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_W4.0mm_StaggerEven_Horizontal_FlatSideUp +TO-92 horizontal, leads molded, narrow, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-92_Wide +TO-92 leads molded, wide, drill 0.75mm (see NXP sot054_po.pdf) +to-92 sc-43 sc-43a sot54 PA33 transistor +0 +3 +3 +Package_TO_SOT_THT +TO-99-6 +TO-99-6 +TO-99-6 +0 +6 +6 +Package_TO_SOT_THT +TO-99-6_Window +TO-99-6_Window, Window +TO-99-6_Window Window +0 +6 +6 +Package_TO_SOT_THT +TO-99-8 +TO-99-8 +TO-99-8 +0 +8 +8 +Package_TO_SOT_THT +TO-99-8_Window +TO-99-8_Window, Window +TO-99-8_Window Window +0 +8 +8 +Package_TO_SOT_THT +TO-100-10 +TO-100-10 +TO-100-10 +0 +10 +10 +Package_TO_SOT_THT +TO-100-10_Window +TO-100-10_Window, Window +TO-100-10_Window Window +0 +10 +10 +Package_TO_SOT_THT +TO-126-2_Horizontal_TabDown +TO-126-2, Horizontal, RM 5.08mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-126-2_Horizontal_TabUp +TO-126-2, Horizontal, RM 5.08mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-126-2_Vertical +TO-126-2, Vertical, RM 5.08mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-2 Vertical RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-126-3_Horizontal_TabDown +TO-126-3, Horizontal, RM 2.54mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-126-3_Horizontal_TabUp +TO-126-3, Horizontal, RM 2.54mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-126-3_Vertical +TO-126-3, Vertical, RM 2.54mm, see https://www.diodes.com/assets/Package-Files/TO126.pdf +TO-126-3 Vertical RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-218-2_Horizontal_TabDown +TO-218-2, Horizontal, RM 10.95mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-2 Horizontal RM 10.95mm SOT-93 +0 +2 +2 +Package_TO_SOT_THT +TO-218-2_Horizontal_TabUp +TO-218-2, Horizontal, RM 10.95mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-2 Horizontal RM 10.95mm SOT-93 +0 +2 +2 +Package_TO_SOT_THT +TO-218-2_Vertical +TO-218-2, Vertical, RM 10.95mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-2 Vertical RM 10.95mm SOT-93 +0 +2 +2 +Package_TO_SOT_THT +TO-218-3_Horizontal_TabDown +TO-218-3, Horizontal, RM 5.475mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-3 Horizontal RM 5.475mm SOT-93 +0 +3 +3 +Package_TO_SOT_THT +TO-218-3_Horizontal_TabUp +TO-218-3, Horizontal, RM 5.475mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-3 Horizontal RM 5.475mm SOT-93 +0 +3 +3 +Package_TO_SOT_THT +TO-218-3_Vertical +TO-218-3, Vertical, RM 5.475mm, SOT-93, see https://www.vishay.com/docs/95214/fto218.pdf +TO-218-3 Vertical RM 5.475mm SOT-93 +0 +3 +3 +Package_TO_SOT_THT +TO-220-2_Horizontal_TabDown +TO-220-2, Horizontal, RM 5.08mm, see https://www.centralsemi.com/PDFS/CASE/TO-220-2PD.PDF +TO-220-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220-2_Horizontal_TabUp +TO-220-2, Horizontal, RM 5.08mm, see https://www.centralsemi.com/PDFS/CASE/TO-220-2PD.PDF +TO-220-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220-2_Vertical +TO-220-2, Vertical, RM 5.08mm, see https://www.centralsemi.com/PDFS/CASE/TO-220-2PD.PDF +TO-220-2 Vertical RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220-3_Horizontal_TabDown +TO-220-3, Horizontal, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf +TO-220-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220-3_Horizontal_TabUp +TO-220-3, Horizontal, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf +TO-220-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220-3_Vertical +TO-220-3, Vertical, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf +TO-220-3 Vertical RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220-4_Horizontal_TabDown +TO-220-4, Horizontal, RM 2.54mm +TO-220-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_Horizontal_TabUp +TO-220-4, Horizontal, RM 2.54mm +TO-220-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerEven_Lead3.8mm_Vertical +TO-220-4, Vertical, RM 2.54mm, staggered type-2 +TO-220-4 Vertical RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerEven_Lead5.84mm_TabDown +TO-220-4, Horizontal, RM 2.54mm, staggered type-2 +TO-220-4 Horizontal RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-4, Vertical, RM 2.54mm, staggered type-1 +TO-220-4 Vertical RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_P5.08x2.54mm_StaggerOdd_Lead5.84mm_TabDown +TO-220-4, Horizontal, RM 2.54mm, staggered type-1 +TO-220-4 Horizontal RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220-4_Vertical +TO-220-4, Vertical, RM 2.54mm +TO-220-4 Vertical RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220-5_Horizontal_TabDown +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421_straight_lead.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_Horizontal_TabUp +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421_straight_lead.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.7mm_StaggerEven_Lead3.8mm_Vertical +TO-220-5, Vertical, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-2, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Vertical RM 1.7mm Pentawatt Multiwatt-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.7mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-5, Vertical, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-1, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Vertical RM 1.7mm Pentawatt Multiwatt-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.8mm_StaggerEven_Lead7.13mm_TabDown +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-2, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_P3.4x3.8mm_StaggerOdd_Lead7.13mm_TabDown +TO-220-5, Horizontal, RM 1.7mm, Pentawatt, Multiwatt-5, staggered type-1, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421.pdf?domain=www.linear.com, https://www.diodes.com/assets/Package-Files/TO220-5.pdf +TO-220-5 Horizontal RM 1.7mm Pentawatt Multiwatt-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220-5_Vertical +TO-220-5, Vertical, RM 1.7mm, Pentawatt, Multiwatt-5, see http://www.analog.com/media/en/package-pcb-resources/package/pkg_pdf/ltc-legacy-to-220/to-220_5_05-08-1421_straight_lead.pdf +TO-220-5 Vertical RM 1.7mm Pentawatt Multiwatt-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220-7_P2.54x3.7mm_StaggerEven_Lead3.8mm_Vertical +TO-220-7, Vertical, RM 1.27mm, Multiwatt-7, staggered type-2 +TO-220-7 Vertical RM 1.27mm Multiwatt-7 staggered type-2 +0 +7 +7 +Package_TO_SOT_THT +TO-220-7_P2.54x3.7mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-7, Vertical, RM 1.27mm, Multiwatt-7, staggered type-1 +TO-220-7 Vertical RM 1.27mm Multiwatt-7 staggered type-1 +0 +7 +7 +Package_TO_SOT_THT +TO-220-7_P2.54x3.8mm_StaggerEven_Lead5.85mm_TabDown +TO-220-7, Horizontal, RM 1.27mm, Multiwatt-7, staggered type-2 +TO-220-7 Horizontal RM 1.27mm Multiwatt-7 staggered type-2 +0 +7 +7 +Package_TO_SOT_THT +TO-220-7_P2.54x3.8mm_StaggerOdd_Lead5.85mm_TabDown +TO-220-7, Horizontal, RM 1.27mm, Multiwatt-7, staggered type-1 +TO-220-7 Horizontal RM 1.27mm Multiwatt-7 staggered type-1 +0 +7 +7 +Package_TO_SOT_THT +TO-220-8_Vertical +TO-220-8 (Multiwatt8), Vertical, 2.54mm Pitch (http://www.st.com/resource/en/datasheet/tda7264.pdf) +TO-220-9 Vertical 2.54mm Pitch Multiwatt 8 +0 +8 +8 +Package_TO_SOT_THT +TO-220-9_P1.94x3.7mm_StaggerEven_Lead3.8mm_Vertical +TO-220-9, Vertical, RM 0.97mm, Multiwatt-9, staggered type-2 +TO-220-9 Vertical RM 0.97mm Multiwatt-9 staggered type-2 +0 +9 +9 +Package_TO_SOT_THT +TO-220-9_P1.94x3.7mm_StaggerOdd_Lead3.8mm_Vertical +TO-220-9, Vertical, RM 0.97mm, Multiwatt-9, staggered type-1 +TO-220-9 Vertical RM 0.97mm Multiwatt-9 staggered type-1 +0 +9 +9 +Package_TO_SOT_THT +TO-220-9_P1.94x3.8mm_StaggerEven_Lead5.85mm_TabDown +TO-220-9, Horizontal, RM 0.97mm, Multiwatt-9, staggered type-2 +TO-220-9 Horizontal RM 0.97mm Multiwatt-9 staggered type-2 +0 +9 +9 +Package_TO_SOT_THT +TO-220-9_P1.94x3.8mm_StaggerOdd_Lead5.85mm_TabDown +TO-220-9, Horizontal, RM 0.97mm, Multiwatt-9, staggered type-1 +TO-220-9 Horizontal RM 0.97mm Multiwatt-9 staggered type-1 +0 +9 +9 +Package_TO_SOT_THT +TO-220-11_P3.4x2.54mm_StaggerEven_Lead5.84mm_TabDown +TO-220-11, Horizontal, RM 1.7mm, staggered type-2, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Horizontal RM 1.7mm staggered type-2 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x2.54mm_StaggerOdd_Lead5.84mm_TabDown +TO-220-11, Horizontal, RM 1.7mm, staggered type-1, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Horizontal RM 1.7mm staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x5.08mm_StaggerEven_Lead4.58mm_Vertical +TO-220-11, Vertical, RM 1.7mm, staggered type-2, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Vertical RM 1.7mm staggered type-2 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x5.08mm_StaggerOdd_Lead4.85mm_Vertical +TO-220-11, Vertical, RM 1.7mm, staggered type-1, see http://www.st.com/resource/en/datasheet/tda7391lv.pdf +TO-220-11 Vertical RM 1.7mm staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220-11_P3.4x5.08mm_StaggerOdd_Lead8.45mm_TabDown +TO-220-11, Horizontal, RM 1.7mm, staggered type-1, see http://www.ti.com/lit/ds/symlink/lmd18200.pdf +TO-220-11 Horizontal RM 1.7mm staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerEven_Lead4.58mm_Vertical +TO-220-15, Vertical, RM 1.27mm, staggered type-2, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Vertical RM 1.27mm staggered type-2 +0 +15 +15 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerEven_Lead5.84mm_TabDown +TO-220-15, Horizontal, RM 1.27mm, staggered type-2, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Horizontal RM 1.27mm staggered type-2 +0 +15 +15 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerOdd_Lead4.58mm_Vertical +TO-220-15, Vertical, RM 1.27mm, staggered type-1, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Vertical RM 1.27mm staggered type-1 +0 +15 +15 +Package_TO_SOT_THT +TO-220-15_P2.54x2.54mm_StaggerOdd_Lead5.84mm_TabDown +TO-220-15, Horizontal, RM 1.27mm, staggered type-1, see http://www.st.com/resource/en/datasheet/l298.pdf +TO-220-15 Horizontal RM 1.27mm staggered type-1 +0 +15 +15 +Package_TO_SOT_THT +TO-220F-2_Horizontal_TabDown +TO-220F-2, Horizontal, RM 5.08mm, see http://www.onsemi.com/pub/Collateral/FFPF10F150S-D.pdf +TO-220F-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220F-2_Horizontal_TabUp +TO-220F-2, Horizontal, RM 5.08mm, see http://www.onsemi.com/pub/Collateral/FFPF10F150S-D.pdf +TO-220F-2 Horizontal RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220F-2_Vertical +TO-220F-2, Vertical, RM 5.08mm, see http://www.onsemi.com/pub/Collateral/FFPF10F150S-D.pdf +TO-220F-2 Vertical RM 5.08mm +0 +2 +2 +Package_TO_SOT_THT +TO-220F-3_Horizontal_TabDown +TO-220F-3, Horizontal, RM 2.54mm, see http://www.st.com/resource/en/datasheet/stp20nm60.pdf +TO-220F-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220F-3_Horizontal_TabUp +TO-220F-3, Horizontal, RM 2.54mm, see http://www.st.com/resource/en/datasheet/stp20nm60.pdf +TO-220F-3 Horizontal RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220F-3_Vertical +TO-220F-3, Vertical, RM 2.54mm, see http://www.st.com/resource/en/datasheet/stp20nm60.pdf +TO-220F-3 Vertical RM 2.54mm +0 +3 +3 +Package_TO_SOT_THT +TO-220F-4_Horizontal_TabDown +TO-220F-4, Horizontal, RM 2.54mm, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_Horizontal_TabUp +TO-220F-4, Horizontal, RM 2.54mm, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x2.05mm_StaggerEven_Lead1.85mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-2, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x2.05mm_StaggerOdd_Lead1.85mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-1, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-2, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-2 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_P5.08x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-4, Vertical, RM 2.54mm, staggered type-1, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm staggered type-1 +0 +4 +4 +Package_TO_SOT_THT +TO-220F-4_Vertical +TO-220F-4, Vertical, RM 2.54mm, see https://www.njr.com/semicon/PDF/package/TO-220F-4_E.pdf +TO-220F-4 Vertical RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-220F-5_Horizontal_TabDown +TO-220F-5, Horizontal, RM 1.7mm, PentawattF-, MultiwattF-5 +TO-220F-5 Horizontal RM 1.7mm PentawattF- MultiwattF-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_Horizontal_TabUp +TO-220F-5, Horizontal, RM 1.7mm, PentawattF-, MultiwattF-5 +TO-220F-5 Horizontal RM 1.7mm PentawattF- MultiwattF-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x2.06mm_StaggerEven_Lead1.86mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-2 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x2.06mm_StaggerOdd_Lead1.86mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-1 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-2 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-2 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_P3.4x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5, staggered type-1 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 staggered type-1 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-5_Vertical +TO-220F-5, Vertical, RM 1.7mm, PentawattF-, MultiwattF-5 +TO-220F-5 Vertical RM 1.7mm PentawattF- MultiwattF-5 +0 +5 +5 +Package_TO_SOT_THT +TO-220F-7_P2.54x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-7, Vertical, RM 1.27mm, staggered type-2 +TO-220F-7 Vertical RM 1.27mm staggered type-2 +0 +7 +7 +Package_TO_SOT_THT +TO-220F-7_P2.54x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-7, Vertical, RM 1.27mm, staggered type-1 +TO-220F-7 Vertical RM 1.27mm staggered type-1 +0 +7 +7 +Package_TO_SOT_THT +TO-220F-9_P1.8x3.7mm_StaggerEven_Lead3.5mm_Vertical +TO-220F-9, Vertical, RM 0.9mm, staggered type-2 +TO-220F-9 Vertical RM 0.9mm staggered type-2 +0 +9 +9 +Package_TO_SOT_THT +TO-220F-9_P1.8x3.7mm_StaggerOdd_Lead3.5mm_Vertical +TO-220F-9, Vertical, RM 0.9mm, staggered type-1 +TO-220F-9 Vertical RM 0.9mm staggered type-1 +0 +9 +9 +Package_TO_SOT_THT +TO-220F-11_P3.4x5.08mm_StaggerEven_Lead5.08mm_Vertical +TO-220F-11, Vertical, RM 1.7mm, MultiwattF-11, staggered type-2, see http://www.ti.com/lit/ds/symlink/lm3886.pdf +TO-220F-11 Vertical RM 1.7mm MultiwattF-11 staggered type-2 +0 +11 +11 +Package_TO_SOT_THT +TO-220F-11_P3.4x5.08mm_StaggerOdd_Lead5.08mm_Vertical +TO-220F-11, Vertical, RM 1.7mm, MultiwattF-11, staggered type-1, see http://www.ti.com/lit/ds/symlink/lm3886.pdf +TO-220F-11 Vertical RM 1.7mm MultiwattF-11 staggered type-1 +0 +11 +11 +Package_TO_SOT_THT +TO-220F-15_P2.54x5.08mm_StaggerEven_Lead5.08mm_Vertical +TO-220F-15, Vertical, RM 1.27mm, MultiwattF-15, staggered type-2 +TO-220F-15 Vertical RM 1.27mm MultiwattF-15 staggered type-2 +0 +15 +15 +Package_TO_SOT_THT +TO-220F-15_P2.54x5.08mm_StaggerOdd_Lead5.08mm_Vertical +TO-220F-15, Vertical, RM 1.27mm, MultiwattF-15, staggered type-1 +TO-220F-15 Vertical RM 1.27mm MultiwattF-15 staggered type-1 +0 +15 +15 +Package_TO_SOT_THT +TO-247-2_Horizontal_TabDown +TO-247-2, Horizontal, RM 10.9mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-247-2_Horizontal_TabUp +TO-247-2, Horizontal, RM 10.9mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-247-2_Vertical +TO-247-2, Vertical, RM 10.9mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-2 Vertical RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-247-3_Horizontal_TabDown +TO-247-3, Horizontal, RM 5.45mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-247-3_Horizontal_TabUp +TO-247-3, Horizontal, RM 5.45mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-247-3_Vertical +TO-247-3, Vertical, RM 5.45mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-247-4_Horizontal_TabDown +TO-247-4, Horizontal, RM 2.54mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-247-4_Horizontal_TabUp +TO-247-4, Horizontal, RM 2.54mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-4 Horizontal RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-247-4_Vertical +TO-247-4, Vertical, RM 2.54mm, see https://toshiba.semicon-storage.com/us/product/mosfet/to-247-4l.html +TO-247-4 Vertical RM 2.54mm +0 +4 +4 +Package_TO_SOT_THT +TO-247-5_Horizontal_TabDown +TO-247-5, Horizontal, RM 2.54mm, see http://ww1.microchip.com/downloads/en/DeviceDoc/20005685A.pdf +TO-247-5 Horizontal RM 2.54mm +0 +5 +5 +Package_TO_SOT_THT +TO-247-5_Horizontal_TabUp +TO-247-5, Horizontal, RM 2.54mm, see http://ww1.microchip.com/downloads/en/DeviceDoc/20005685A.pdf +TO-247-5 Horizontal RM 2.54mm +0 +5 +5 +Package_TO_SOT_THT +TO-247-5_Vertical +TO-247-5, Vertical, RM 2.54mm, see http://ww1.microchip.com/downloads/en/DeviceDoc/20005685A.pdf +TO-247-5 Vertical RM 2.54mm +0 +5 +5 +Package_TO_SOT_THT +TO-251-2-1EP_Horizontal_TabDown +TO-251-2, Horizontal, RM 4.58mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-2 Horizontal RM 4.58mm IPAK +0 +3 +3 +Package_TO_SOT_THT +TO-251-2_Vertical +TO-251-2, Vertical, RM 4.58mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-2 Vertical RM 4.58mm IPAK +0 +2 +2 +Package_TO_SOT_THT +TO-251-3-1EP_Horizontal_TabDown +TO-251-3, Horizontal, RM 2.29mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-3 Horizontal RM 2.29mm IPAK +0 +4 +4 +Package_TO_SOT_THT +TO-251-3_Vertical +TO-251-3, Vertical, RM 2.29mm, IPAK, see https://www.diodes.com/assets/Package-Files/TO251.pdf +TO-251-3 Vertical RM 2.29mm IPAK +0 +3 +3 +Package_TO_SOT_THT +TO-262-3-1EP_Horizontal_TabDown +TO-262-3, Horizontal, RM 2.54mm, IIPAK, I2PAK, see http://www.onsemi.com/pub/Collateral/EN8586-D.PDF +TO-262-3 Horizontal RM 2.54mm IIPAK I2PAK +0 +4 +4 +Package_TO_SOT_THT +TO-262-3_Vertical +TO-262-3, Vertical, RM 2.54mm, IIPAK, I2PAK, see http://www.onsemi.com/pub/Collateral/EN8586-D.PDF +TO-262-3 Vertical RM 2.54mm IIPAK I2PAK +0 +3 +3 +Package_TO_SOT_THT +TO-262-5-1EP_Horizontal_TabDown +TO-262-5, Horizontal, RM 1.7mm, IIPAK, I2PAK, see http://pdf.datasheetcatalog.com/datasheet/irf/iris4011.pdf +TO-262-5 Horizontal RM 1.7mm IIPAK I2PAK +0 +6 +6 +Package_TO_SOT_THT +TO-262-5_Vertical +TO-262-5, Vertical, RM 1.7mm, IIPAK, I2PAK, see http://pdf.datasheetcatalog.com/datasheet/irf/iris4011.pdf +TO-262-5 Vertical RM 1.7mm IIPAK I2PAK +0 +5 +5 +Package_TO_SOT_THT +TO-264-2_Horizontal_TabDown +TO-264-2, Horizontal, RM 10.9mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-264-2_Horizontal_TabUp +TO-264-2, Horizontal, RM 10.9mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-2 Horizontal RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-264-2_Vertical +TO-264-2, Vertical, RM 10.9mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-2 Vertical RM 10.9mm +0 +2 +2 +Package_TO_SOT_THT +TO-264-3_Horizontal_TabDown +TO-264-3, Horizontal, RM 5.45mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-264-3_Horizontal_TabUp +TO-264-3, Horizontal, RM 5.45mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-3 Horizontal RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-264-3_Vertical +TO-264-3, Vertical, RM 5.45mm, see https://www.fairchildsemi.com/package-drawings/TO/TO264A03.pdf +TO-264-3 Vertical RM 5.45mm +0 +3 +3 +Package_TO_SOT_THT +TO-264-5_Horizontal_TabDown +TO-264-5, Horizontal, RM 3.81mm, see https://www.onsemi.com/pub/Collateral/NJL3281D-D.PDF +TO-264-5 Horizontal RM 3.81mm +0 +5 +5 +Package_TO_SOT_THT +TO-264-5_Horizontal_TabUp +TO-264-5, Horizontal, RM 3.81mm, see https://www.onsemi.com/pub/Collateral/NJL3281D-D.PDF +TO-264-5 Horizontal RM 3.81mm +0 +5 +5 +Package_TO_SOT_THT +TO-264-5_Vertical +TO-264-5, Vertical, RM 3.81mm, see https://www.onsemi.com/pub/Collateral/NJL3281D-D.PDF +TO-264-5 Vertical RM 3.81mm +0 +5 +5 +Potentiometer_SMD +Potentiometer_ACP_CA6-VSMD_Vertical +Potentiometer, vertical, ACP CA6-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/06/01-ACP-CA6.pdf +Potentiometer vertical ACP CA6-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA6-VSMD_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA6-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/06/01-ACP-CA6.pdf +Potentiometer vertical hole ACP CA6-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA9-VSMD_Vertical +Potentiometer, vertical, ACP CA9-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical ACP CA9-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA9-VSMD_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA9-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical hole ACP CA9-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA14-VSMD_Vertical +Potentiometer, vertical, ACP CA14-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical ACP CA14-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_ACP_CA14-VSMD_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA14-VSMD, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical hole ACP CA14-VSMD +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214G_Horizontal +Potentiometer, horizontal, Bourns 3214G, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer horizontal Bourns 3214G +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214J_Horizontal +Potentiometer, horizontal, Bourns 3214J, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer horizontal Bourns 3214J +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214W_Vertical +Potentiometer, vertical, Bourns 3214W, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer vertical Bourns 3214W +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3214X_Vertical +Potentiometer, vertical, Bourns 3214X, https://www.bourns.com/docs/Product-Datasheets/3214.pdf +Potentiometer vertical Bourns 3214X +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224G_Horizontal +Potentiometer, horizontal, Bourns 3224G, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer horizontal Bourns 3224G +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224J_Horizontal +Potentiometer, horizontal, Bourns 3224J, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer horizontal Bourns 3224J +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224W_Vertical +Potentiometer, vertical, Bourns 3224W, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer vertical Bourns 3224W +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3224X_Vertical +Potentiometer, vertical, Bourns 3224X, https://www.bourns.com/docs/Product-Datasheets/3224.pdf +Potentiometer vertical Bourns 3224X +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3269P_Horizontal +Potentiometer, horizontal, Bourns 3269P, https://www.bourns.com/docs/Product-Datasheets/3269.pdf +Potentiometer horizontal Bourns 3269P +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3269W_Vertical +Potentiometer, vertical, Bourns 3269W, https://www.bourns.com/docs/Product-Datasheets/3269.pdf +Potentiometer vertical Bourns 3269W +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3269X_Horizontal +Potentiometer, horizontal, Bourns 3269X, https://www.bourns.com/docs/Product-Datasheets/3269.pdf +Potentiometer horizontal Bourns 3269X +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314G_Vertical +Potentiometer, vertical, Bourns 3314G, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical Bourns 3314G +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314J_Vertical +Potentiometer, vertical, Bourns 3314J, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical Bourns 3314J +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314R-1_Vertical_Hole +Potentiometer, vertical, shaft hole, Bourns 3314R-1, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical hole Bourns 3314R-1 +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314R-GM5_Vertical +Potentiometer, vertical, Bourns 3314R-GM5, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer vertical Bourns 3314R-GM5 +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_3314S_Horizontal +Potentiometer, horizontal, Bourns 3314S, http://www.bourns.com/docs/Product-Datasheets/3314.pdf +Potentiometer horizontal Bourns 3314S +0 +3 +3 +Potentiometer_SMD +Potentiometer_Bourns_PRS11S_Vertical +Potentiometer, vertical, Bourns PRS11S, http://www.bourns.com/docs/Product-Datasheets/PRS11S.pdf +Potentiometer vertical Bourns PRS11S +0 +5 +5 +Potentiometer_SMD +Potentiometer_Bourns_TC33X_Vertical +Potentiometer, Bourns, TC33X, Vertical, https://www.bourns.com/pdfs/TC33.pdf +Potentiometer Bourns TC33X Vertical +0 +3 +3 +Potentiometer_SMD +Potentiometer_Vishay_TS53YJ_Vertical +Potentiometer, vertical, Vishay TS53YJ, https://www.vishay.com/docs/51008/ts53.pdf +Potentiometer vertical Vishay TS53YJ +0 +3 +3 +Potentiometer_SMD +Potentiometer_Vishay_TS53YL_Vertical +Potentiometer, vertical, Vishay TS53YL, https://www.vishay.com/docs/51008/ts53.pdf +Potentiometer vertical Vishay TS53YL +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA6-H2,5_Horizontal +Potentiometer, horizontal, ACP CA6-H2,5, http://www.acptechnologies.com/wp-content/uploads/2017/06/01-ACP-CA6.pdf +Potentiometer horizontal ACP CA6-H2,5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-H2,5_Horizontal +Potentiometer, horizontal, ACP CA9-H2,5, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer horizontal ACP CA9-H2,5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-H3,8_Horizontal +Potentiometer, horizontal, ACP CA9-H3,8, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer horizontal ACP CA9-H3,8 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-H5_Horizontal +Potentiometer, horizontal, ACP CA9-H5, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer horizontal ACP CA9-H5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-V10_Vertical +Potentiometer, vertical, ACP CA9-V10, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical ACP CA9-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA9-V10_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA9-V10, http://www.acptechnologies.com/wp-content/uploads/2017/05/02-ACP-CA9-CE9.pdf +Potentiometer vertical hole ACP CA9-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14-H2,5_Horizontal +Potentiometer, horizontal, ACP CA14-H2,5, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer horizontal ACP CA14-H2,5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14-H4_Horizontal +Potentiometer, horizontal, ACP CA14-H4, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer horizontal ACP CA14-H4 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14-H5_Horizontal +Potentiometer, horizontal, ACP CA14-H5, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer horizontal ACP CA14-H5 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14V-15_Vertical +Potentiometer, vertical, ACP CA14V-15, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical ACP CA14V-15 +0 +3 +3 +Potentiometer_THT +Potentiometer_ACP_CA14V-15_Vertical_Hole +Potentiometer, vertical, shaft hole, ACP CA14V-15, http://www.acptechnologies.com/wp-content/uploads/2017/10/03-ACP-CA14-CE14.pdf +Potentiometer vertical hole ACP CA14V-15 +0 +3 +3 +Potentiometer_THT +Potentiometer_Alpha_RD901F-40-00D_Single_Vertical +Potentiometer, vertical, 9mm, single, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alpha_RD901F-40-00D_Single_Vertical_CircularHoles +Potentiometer, vertical, 9mm, single, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alpha_RD902F-40-00D_Dual_Vertical +Potentiometer, vertical, 9mm, dual, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm dual +0 +8 +6 +Potentiometer_THT +Potentiometer_Alpha_RD902F-40-00D_Dual_Vertical_CircularHoles +Potentiometer, vertical, 9mm, dual, http://www.taiwanalpha.com.tw/downloads?target=products&id=113 +potentiometer vertical 9mm dual +0 +8 +6 +Potentiometer_THT +Potentiometer_Alps_RK09K_Single_Horizontal +Potentiometer, horizontal, Alps RK09K Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09K/RK09K_list.html +Potentiometer horizontal Alps RK09K Single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alps_RK09K_Single_Vertical +Potentiometer, vertical, Alps RK09K Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09K/RK09K_list.html +Potentiometer vertical Alps RK09K Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK09L_Double_Horizontal +Potentiometer, horizontal, Alps RK09L Double, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer horizontal Alps RK09L Double +0 +8 +6 +Potentiometer_THT +Potentiometer_Alps_RK09L_Double_Vertical +Potentiometer, vertical, Alps RK09L Double, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer vertical Alps RK09L Double +0 +6 +6 +Potentiometer_THT +Potentiometer_Alps_RK09L_Single_Horizontal +Potentiometer, horizontal, Alps RK09L Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer horizontal Alps RK09L Single +0 +5 +3 +Potentiometer_THT +Potentiometer_Alps_RK09L_Single_Vertical +Potentiometer, vertical, Alps RK09L Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09L/RK09L_list.html +Potentiometer vertical Alps RK09L Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK09Y11_Single_Horizontal +Potentiometer, horizontal, Alps RK09Y11 Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK09Y11/RK09Y11_list.html +Potentiometer horizontal Alps RK09Y11 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK097_Dual_Horizontal +Potentiometer, horizontal, Alps RK097 Dual, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK097/RK097_list.html +Potentiometer horizontal Alps RK097 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Alps_RK097_Single_Horizontal +Potentiometer, horizontal, Alps RK097 Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK097/RK097_list.html +Potentiometer horizontal Alps RK097 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Alps_RK163_Dual_Horizontal +Potentiometer, horizontal, Alps RK163 Dual, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK16/RK16_list.html +Potentiometer horizontal Alps RK163 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Alps_RK163_Single_Horizontal +Potentiometer, horizontal, Alps RK163 Single, http://www.alps.com/prod/info/E/HTML/Potentiometer/RotaryPotentiometers/RK16/RK16_list.html +Potentiometer horizontal Alps RK163 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3005_Horizontal +Potentiometer, horizontal, Bourns 3005, http://www.bourns.com/docs/Product-Datasheets/3005.pdf +Potentiometer horizontal Bourns 3005 +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3006P_Horizontal +Potentiometer, horizontal, Bourns 3006P, https://www.bourns.com/docs/Product-Datasheets/3006.pdf +Potentiometer horizontal Bourns 3006P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3006W_Horizontal +Potentiometer, horizontal, Bourns 3006W, https://www.bourns.com/docs/Product-Datasheets/3006.pdf +Potentiometer horizontal Bourns 3006W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3006Y_Horizontal +Potentiometer, horizontal, Bourns 3006Y, https://www.bourns.com/docs/Product-Datasheets/3006.pdf +Potentiometer horizontal Bourns 3006Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3009P_Horizontal +Potentiometer, horizontal, Bourns 3009P, http://www.bourns.com/docs/Product-Datasheets/3009.pdf +Potentiometer horizontal Bourns 3009P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3009Y_Horizontal +Potentiometer, horizontal, Bourns 3009Y, http://www.bourns.com/docs/Product-Datasheets/3009.pdf +Potentiometer horizontal Bourns 3009Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266P_Horizontal +Potentiometer, horizontal, Bourns 3266P, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer horizontal Bourns 3266P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266W_Vertical +Potentiometer, vertical, Bourns 3266W, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer vertical Bourns 3266W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266X_Horizontal +Potentiometer, horizontal, Bourns 3266X, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer horizontal Bourns 3266X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266Y_Vertical +Potentiometer, vertical, Bourns 3266Y, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer vertical Bourns 3266Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3266Z_Horizontal +Potentiometer, horizontal, Bourns 3266Z, https://www.bourns.com/docs/Product-Datasheets/3266.pdf +Potentiometer horizontal Bourns 3266Z +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296P_Horizontal +Potentiometer, horizontal, Bourns 3296P, https://www.bourns.com/pdfs/3296.pdf +Potentiometer horizontal Bourns 3296P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296W_Vertical +Potentiometer, vertical, Bourns 3296W, https://www.bourns.com/pdfs/3296.pdf +Potentiometer vertical Bourns 3296W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296X_Horizontal +Potentiometer, horizontal, Bourns 3296X, https://www.bourns.com/pdfs/3296.pdf +Potentiometer horizontal Bourns 3296X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296Y_Vertical +Potentiometer, vertical, Bourns 3296Y, https://www.bourns.com/pdfs/3296.pdf +Potentiometer vertical Bourns 3296Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3296Z_Horizontal +Potentiometer, horizontal, Bourns 3296Z, https://www.bourns.com/pdfs/3296.pdf +Potentiometer horizontal Bourns 3296Z +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299P_Horizontal +Potentiometer, horizontal, Bourns 3299P, https://www.bourns.com/pdfs/3299.pdf +Potentiometer horizontal Bourns 3299P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299W_Vertical +Potentiometer, vertical, Bourns 3299W, https://www.bourns.com/pdfs/3299.pdf +Potentiometer vertical Bourns 3299W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299X_Horizontal +Potentiometer, horizontal, Bourns 3299X, https://www.bourns.com/pdfs/3299.pdf +Potentiometer horizontal Bourns 3299X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299Y_Vertical +Potentiometer, vertical, Bourns 3299Y, https://www.bourns.com/pdfs/3299.pdf +Potentiometer vertical Bourns 3299Y +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3299Z_Horizontal +Potentiometer, horizontal, Bourns 3299Z, https://www.bourns.com/pdfs/3299.pdf +Potentiometer horizontal Bourns 3299Z +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339H_Vertical +Potentiometer, vertical, Bourns 3339H, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer vertical Bourns 3339H +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339P_Vertical +Potentiometer, vertical, Bourns 3339P, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer vertical Bourns 3339P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339P_Vertical_HandSoldering +Potentiometer, vertical, Bourns 3339P, hand-soldering, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer vertical Bourns 3339P hand-soldering +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339S_Horizontal +Potentiometer, horizontal, Bourns 3339S, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer horizontal Bourns 3339S +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3339W_Horizontal +Potentiometer, horizontal, Bourns 3339W, http://www.bourns.com/docs/Product-Datasheets/3339.pdf +Potentiometer horizontal Bourns 3339W +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386C_Horizontal +Potentiometer, horizontal, Bourns 3386C, https://www.bourns.com/pdfs/3386.pdf +Potentiometer horizontal Bourns 3386C +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386F_Vertical +Potentiometer, vertical, Bourns 3386F, https://www.bourns.com/pdfs/3386.pdf +Potentiometer vertical Bourns 3386F +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386P_Vertical +Potentiometer, vertical, Bourns 3386P, https://www.bourns.com/pdfs/3386.pdf +Potentiometer vertical Bourns 3386P +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_3386X_Horizontal +Potentiometer, horizontal, Bourns 3386X, https://www.bourns.com/pdfs/3386.pdf +Potentiometer horizontal Bourns 3386X +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_PTA1543_Single_Slide +Bourns single-gang slide potentiometer, 15.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 15.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA2043_Single_Slide +Bourns single-gang slide potentiometer, 20.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 20.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA3043_Single_Slide +Bourns single-gang slide potentiometer, 30.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 30.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA4543_Single_Slide +Bourns single-gang slide potentiometer, 45.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 45.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTA6043_Single_Slide +Bourns single-gang slide potentiometer, 60.0mm travel, https://www.bourns.com/docs/Product-Datasheets/pta.pdf +Bourns single-gang slide potentiometer 60.0mm +0 +7 +4 +Potentiometer_THT +Potentiometer_Bourns_PTV09A-1_Single_Vertical +Potentiometer, vertical, Bourns PTV09A-1 Single, http://www.bourns.com/docs/Product-Datasheets/ptv09.pdf +Potentiometer vertical Bourns PTV09A-1 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Bourns_PTV09A-2_Single_Horizontal +Potentiometer, horizontal, Bourns PTV09A-2 Single, http://www.bourns.com/docs/Product-Datasheets/ptv09.pdf +Potentiometer horizontal Bourns PTV09A-2 Single +0 +5 +3 +Potentiometer_THT +Potentiometer_Omeg_PC16BU_Horizontal +Potentiometer, horizontal, Omeg PC16BU, http://www.omeg.co.uk/pc6bubrc.htm +Potentiometer horizontal Omeg PC16BU +0 +3 +3 +Potentiometer_THT +Potentiometer_Omeg_PC16BU_Vertical +Potentiometer, vertical, Omeg PC16BU, http://www.omeg.co.uk/pc6bubrc.htm +Potentiometer vertical Omeg PC16BU +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PC-16_Dual_Horizontal +Potentiometer, horizontal, Piher PC-16 Dual, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer horizontal Piher PC-16 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Piher_PC-16_Single_Horizontal +Potentiometer, horizontal, Piher PC-16 Single, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer horizontal Piher PC-16 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PC-16_Single_Vertical +Potentiometer, vertical, Piher PC-16 Single, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer vertical Piher PC-16 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PC-16_Triple_Horizontal +Potentiometer, horizontal, Piher PC-16 Triple, http://www.piher-nacesa.com/pdf/20-PC16v03.pdf +Potentiometer horizontal Piher PC-16 Triple +0 +9 +9 +Potentiometer_THT +Potentiometer_Piher_PT-6-H_Horizontal +Potentiometer, horizontal, Piher PT-6-H, http://www.piher-nacesa.com/pdf/11-PT6v03.pdf +Potentiometer horizontal Piher PT-6-H +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-6-V_Vertical +Potentiometer, vertical, Piher PT-6-V, http://www.piher-nacesa.com/pdf/11-PT6v03.pdf +Potentiometer vertical Piher PT-6-V +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-6-V_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-6-V, http://www.piher-nacesa.com/pdf/11-PT6v03.pdf +Potentiometer vertical hole Piher PT-6-V +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-H01_Horizontal +Potentiometer, horizontal, Piher PT-10-H01, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer horizontal Piher PT-10-H01 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-H05_Horizontal +Potentiometer, horizontal, Piher PT-10-H05, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer horizontal Piher PT-10-H05 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-V05_Vertical +Potentiometer, vertical, Piher PT-10-V05, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer vertical Piher PT-10-V05 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-V10_Vertical +Potentiometer, vertical, Piher PT-10-V10, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer vertical Piher PT-10-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-10-V10_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-10-V10, http://www.piher-nacesa.com/pdf/12-PT10v03.pdf +Potentiometer vertical hole Piher PT-10-V10 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H01_Horizontal +Potentiometer, horizontal, Piher PT-15-H01, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H01 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H05_Horizontal +Potentiometer, horizontal, Piher PT-15-H05, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H05 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H06_Horizontal +Potentiometer, horizontal, Piher PT-15-H06, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H06 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-H25_Horizontal +Potentiometer, horizontal, Piher PT-15-H25, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer horizontal Piher PT-15-H25 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V02_Vertical +Potentiometer, vertical, Piher PT-15-V02, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical Piher PT-15-V02 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V02_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-15-V02, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical hole Piher PT-15-V02 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V15_Vertical +Potentiometer, vertical, Piher PT-15-V15, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical Piher PT-15-V15 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_PT-15-V15_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher PT-15-V15, http://www.piher-nacesa.com/pdf/14-PT15v03.pdf +Potentiometer vertical hole Piher PT-15-V15 +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_T-16H_Double_Horizontal +Potentiometer, horizontal, Piher T-16H Double, http://www.piher-nacesa.com/pdf/22-T16v03.pdf +Potentiometer horizontal Piher T-16H Double +0 +6 +6 +Potentiometer_THT +Potentiometer_Piher_T-16H_Single_Horizontal +Potentiometer, horizontal, Piher T-16H Single, http://www.piher-nacesa.com/pdf/22-T16v03.pdf +Potentiometer horizontal Piher T-16H Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Piher_T-16L_Single_Vertical_Hole +Potentiometer, vertical, shaft hole, Piher T-16L Single, http://www.piher-nacesa.com/pdf/22-T16v03.pdf +Potentiometer vertical hole Piher T-16L Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Runtron_RM-063_Horizontal +Potentiometer, horizontal, Trimmer, RM-063 http://www.runtron.com/down/PDF%20Datasheet/Carbon%20Film%20Potentiometer/RM065%20RM063.pdf +Potentiometer Trimmer RM-063 +0 +3 +3 +Potentiometer_THT +Potentiometer_Runtron_RM-065_Vertical +Potentiometer, vertical, Trimmer, RM-065 http://www.runtron.com/down/PDF%20Datasheet/Carbon%20Film%20Potentiometer/RM065%20RM063.pdf +Potentiometer Trimmer RM-065 +0 +3 +3 +Potentiometer_THT +Potentiometer_TT_P0915N +http://www.ttelectronics.com/sites/default/files/download-files/Datasheet_PanelPot_P09xSeries.pdf +potentiometer vertical TT P0915N single +0 +5 +3 +Potentiometer_THT +Potentiometer_Vishay_43_Horizontal +Potentiometer, horizontal, Vishay 43, http://www.vishay.com/docs/57026/43.pdf +Potentiometer horizontal Vishay 43 +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_148-149_Dual_Horizontal +Potentiometer, horizontal, Vishay 148-149 Dual, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148-149 Dual +0 +6 +6 +Potentiometer_THT +Potentiometer_Vishay_148-149_Single_Horizontal +Potentiometer, horizontal, Vishay 148-149 Single, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148-149 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_148-149_Single_Vertical +Potentiometer, vertical, Vishay 148-149 Single, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer vertical Vishay 148-149 Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_148E-149E_Dual_Horizontal +Potentiometer, horizontal, Vishay 148E-149E Dual, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148E-149E Dual +0 +10 +6 +Potentiometer_THT +Potentiometer_Vishay_148E-149E_Single_Horizontal +Potentiometer, horizontal, Vishay 148E-149E Single, http://www.vishay.com/docs/57040/148149.pdf +Potentiometer horizontal Vishay 148E-149E Single +0 +7 +3 +Potentiometer_THT +Potentiometer_Vishay_248BH-249BH_Single_Horizontal +Potentiometer, horizontal, Vishay 248BH-249BH Single, http://www.vishay.com/docs/57054/248249.pdf +Potentiometer horizontal Vishay 248BH-249BH Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_248GJ-249GJ_Single_Horizontal +Potentiometer, horizontal, Vishay 248GJ-249GJ Single, http://www.vishay.com/docs/57054/248249.pdf +Potentiometer horizontal Vishay 248GJ-249GJ Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_248GJ-249GJ_Single_Vertical +Potentiometer, vertical, Vishay 248GJ-249GJ Single, http://www.vishay.com/docs/57054/248249.pdf +Potentiometer vertical Vishay 248GJ-249GJ Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T7-YA_Single_Vertical +Potentiometer, vertical, Vishay T7-YA Single, http://www.vishay.com/docs/51015/t7.pdf +Potentiometer vertical Vishay T7-YA Single +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T73XW_Horizontal +Potentiometer, horizontal, Vishay T73XW, http://www.vishay.com/docs/51016/t73.pdf +Potentiometer horizontal Vishay T73XW +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T73XX_Horizontal +Potentiometer, horizontal, Vishay T73XX, http://www.vishay.com/docs/51016/t73.pdf +Potentiometer horizontal Vishay T73XX +0 +3 +3 +Potentiometer_THT +Potentiometer_Vishay_T73YP_Vertical +Potentiometer, vertical, Vishay T73YP, http://www.vishay.com/docs/51016/t73.pdf +Potentiometer vertical Vishay T73YP +0 +3 +3 +RF +Skyworks_SKY13575_639LF +http://www.skyworksinc.com/uploads/documents/SKY13575_639LF_203270D.pdf +Skyworks +0 +19 +15 +RF +Skyworks_SKY65404-31 +http://www.skyworksinc.com/uploads/documents/SKY65404_31_201512K.pdf +Skyworks +0 +7 +7 +RF_Antenna +Abracon_APAES868R8060C16-T +Abracon RHCP ceramic patch antenna 854-882Mhz, 5dBi +APAES patch antenna +0 +1 +1 +RF_Antenna +Coilcraft_MA5532-AE_RFID +RFID Transponder Coil +antenna rfid coilcraft +0 +2 +2 +RF_Antenna +Johanson_2450AT18x100 +Johanson 2450AT43F0100 SMD antenna 2400-2500Mhz, -0.5dBi, https://www.johansontechnology.com/datasheets/2450AT18A100/2450AT18A100.pdf +antenna +0 +2 +2 +RF_Antenna +Johanson_2450AT43F0100 +Johanson 2450AT43F0100 SMD antenna 2400-2500Mhz, 1dBi, https://www.johansontechnology.com/datasheets/2450AT43F0100/2450AT43F0100.pdf +antenna +0 +2 +2 +RF_Antenna +Pulse_W3011 +Pulse RF Antenna, 4mm Clearance +antenna rf +0 +3 +2 +RF_Antenna +Texas_SWRA117D_2.4GHz_Left +http://www.ti.com/lit/an/swra117d/swra117d.pdf +PCB antenna +0 +2 +2 +RF_Antenna +Texas_SWRA117D_2.4GHz_Right +http://www.ti.com/lit/an/swra117d/swra117d.pdf +PCB antenna +0 +2 +2 +RF_Antenna +Texas_SWRA416_868MHz_915MHz +http://www.ti.com/lit/an/swra416/swra416.pdf +PCB antenna +0 +20 +1 +RF_Converter +Anaren_0805_2012Metric-6 +https://cdn.anaren.com/product-documents/Xinger/DirectionalCouplers/DC4759J5020AHF/DC4759J5020AHF_DataSheet(Rev_E).pdf +coupler rf +0 +6 +6 +RF_Converter +Balun_Johanson_1.6x0.8mm +6-pin 1.6x0.8 mm balun footprint +Johanson balun filter +0 +6 +6 +RF_Converter +Balun_Johanson_5400BL15B050E +https://www.johansontechnology.com/datasheets/5400BL15B050/5400BL15B050.pdf +balun RF +0 +6 +6 +RF_Converter +RF_Attenuator_Susumu_PAT1220 +http://www.susumu-usa.com/pdf/Foot_Print_38.pdf, https://www.susumu.co.jp/common/pdf/n_catalog_partition16_en.pdf +2mm 1.2mm +0 +3 +3 +RF_GPS +Linx_RXM-GPS +GPS Module, Linx +gps linx +0 +22 +22 +RF_GPS +SIM28ML +https://simcom.ee/documents/SIM28ML/SIM28ML_Hardware%20Design_V1.01.pdf +SIM28ML GPS +0 +18 +18 +RF_GPS +Sierra_XA11X0 +QFN-24, Pitch 1.20 no EP, https://source.sierrawireless.com/resources/airprime/hardware_specs_user_guides/airprime_xm1100_product_technical_specification +QFN-24 P1.20 +0 +24 +24 +RF_GPS +Sierra_XM11X0 +QFN-20, Pitch 1.20 no EP, https://source.sierrawireless.com/resources/airprime/hardware_specs_user_guides/airprime_xm1100_product_technical_specification +QFN-20 P1.20 +0 +20 +20 +RF_GPS +ublox_LEA +ublox LEA 6/7/8, (https://www.u-blox.com/sites/default/files/LEA-M8S-M8T-FW3_HardwareIntegrationManual_%28UBX-15030060%29.pdf) +GPS ublox LEA 6/7/8 +0 +28 +28 +RF_GPS +ublox_MAX +ublox MAX 6/7/8, (https://www.u-blox.com/sites/default/files/MAX-8-M8-FW3_HardwareIntegrationManual_%28UBX-15030059%29.pdf) +GPS ublox MAX 6/7/8 +0 +18 +18 +RF_GPS +ublox_NEO +ublox NEO 6/7/8, (https://www.u-blox.com/sites/default/files/NEO-8Q-NEO-M8-FW3_HardwareIntegrationManual_%28UBX-15029985%29_0.pdf) +GPS ublox NEO 6/7/8 +0 +24 +24 +RF_GPS +ublox_SAM-M8Q +GPS Module, 15.5x15.5x6.3mm, https://www.u-blox.com/sites/default/files/SAM-M8Q_HardwareIntegrationManual_%28UBX-16018358%29.pdf +ublox SAM-M8Q +0 +100 +20 +RF_GPS +ublox_SAM-M8Q_HandSolder +GPS Module, 15.5x15.5x6.3mm, https://www.u-blox.com/sites/default/files/SAM-M8Q_HardwareIntegrationManual_%28UBX-16018358%29.pdf +ublox SAM-M8Q +0 +20 +20 +RF_GPS +ublox_ZED +ublox ZED-F9, https://www.u-blox.com/sites/default/files/ZED-F9P_DataSheet_%28UBX-17051259%29.pdf +GPS GNSS ublox ZED +0 +102 +55 +RF_GSM +Quectel_BC66 +GSM NB-IoT module, 15.8x17.7x2mm, https://www.quectel.com/UploadImage/Downlad/Quectel_BC66_Hardware_Design_V1.1.pdf +GSM NB-IoT Module BC66 M66 +0 +116 +58 +RF_GSM +SIMCom_SIM800C +Quad-Band GSM/GPRS module, 17.6x15.7x2.3mm, http://simcom.ee/documents/SIM800C/SIM800C_Hardware_Design_V1.05.pdf +GSM Module SIM800C +0 +84 +42 +RF_GSM +SIMCom_SIM900 +Quad-Band GSM/GPRS module, 24x24x3mm, http://simcom.ee/documents/SIM900/SIM900_Hardware%20Design_V2.05.pdf +GSM Module SIM900 +0 +68 +68 +RF_GSM +Telit_xL865 +Telit xL865 familly footprint, http://www.telit.com/fileadmin/user_upload/products/Downloads/3G/Telit_UL865_Hardware_User_Guide_r8.pdf +xL865 gsm umts +0 +52 +48 +RF_GSM +ublox_SARA-G3_LGA-96 +ublox Sara GSM/HSPA modem, https://www.u-blox.com/sites/default/files/SARA-G3-U2_SysIntegrManual_%28UBX-13000995%29.pdf, pag.162 +ublox SARA-G3 SARA-U2 GSM HSPA +0 +192 +96 +RF_Mini-Circuits +Mini-Circuits_BK377 +Footprint for Mini-Circuits case BK377 (https://ww2.minicircuits.com/case_style/BK276.pdf) +Mini-circuits BK377 +0 +14 +14 +RF_Mini-Circuits +Mini-Circuits_BK377_LandPatternPL-005 +Footprint for Mini-Circuits case BK377 (https://ww2.minicircuits.com/case_style/BK276.pdf) according to land-pattern PL-005, including GND vias (https://ww2.minicircuits.com/pcb/98-pl005.pdf) +Mini-circuits VCXO JTOS PL-005 +0 +50 +14 +RF_Mini-Circuits +Mini-Circuits_CD541_H2.08mm +https://ww2.minicircuits.com/case_style/CD541.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CD542_H2.84mm +https://ww2.minicircuits.com/case_style/CD542.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CD542_LandPatternPL-052 +Footprint for Mini-Circuits case CD542 (https://ww2.minicircuits.com/case_style/CD542.pdf) using land-pattern PL-052, including GND-vias (https://ww2.minicircuits.com/pcb/98-pl052.pdf) +MiniCircuits PL-052 CD542 +0 +17 +6 +RF_Mini-Circuits +Mini-Circuits_CD542_LandPatternPL-094 +Footprint for mini circuit case CD542, Land pattern PL-094, pads 5 and 2 connected via insulated copper area below body, vias included (case drawing: https://ww2.minicircuits.com/case_style/CD542.pdf, land pattern drawing: https://ww2.minicircuits.com/pcb/98-pl094.pdf) +mini-circuits CD542 pl-094 +0 +18 +6 +RF_Mini-Circuits +Mini-Circuits_CD636_H4.11mm +https://ww2.minicircuits.com/case_style/CD636.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CD636_LandPatternPL-035 +Footprint for Mini-Circuits case CD636 (https://ww2.minicircuits.com/case_style/CD636.pdf) following land pattern PL-035, including GND-vias (https://ww2.minicircuits.com/pcb/98-pl035.pdf) +mini-circuits pl-035 CD636 +0 +13 +6 +RF_Mini-Circuits +Mini-Circuits_CD637_H5.23mm +https://ww2.minicircuits.com/case_style/CD637.pdf +RF Transformer +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_CK605 +Footprint for Mini-Circuits case CK605 (https://ww2.minicircuits.com/case_style/CK605.pdf) +Mini-Circuits CK605 +0 +16 +16 +RF_Mini-Circuits +Mini-Circuits_CK605_LandPatternPL-012 +Footprint for Mini-Circuits case CK605 (https://ww2.minicircuits.com/case_style/CK605.pdf) following land pattern PL-012, including GND vias (https://ww2.minicircuits.com/pcb/98-pl012.pdf) +Mini-Circuits PL-012 +0 +53 +16 +RF_Mini-Circuits +Mini-Circuits_DB1627 +Mini-Circuits top-hat case DB1627 (https://ww2.minicircuits.com/case_style/DB1627.pdf) +Mini-Circuits DB1627 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_GP731 +Footprint for Mini-Circuits case GP731 (https://ww2.minicircuits.com/case_style/GP731.pdf) +Mini-Circuits GP731 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_GP731_LandPatternPL-176 +Footprint for Mini-Circuits case GP731 (https://ww2.minicircuits.com/case_style/GP731.pdf) following land pattern PL-176, including GND vias (https://www.minicircuits.com/pcb/98-pl176.pdf) +mini-circuits PL-176 +0 +21 +8 +RF_Mini-Circuits +Mini-Circuits_GP1212 +Footprint for Mini-Circuits case GP1212 (https://ww2.minicircuits.com/case_style/GP731.pdf) +mini-circuits GP1212 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_GP1212_LandPatternPL-176 +Footprint for Mini-Circuits case GP1212 (https://ww2.minicircuits.com/case_style/GP731.pdf) following land pattern PL-176, including GND vias (https://www.minicircuits.com/pcb/98-pl176.pdf) +mini-circuits PL-176 +0 +21 +8 +RF_Mini-Circuits +Mini-Circuits_HF1139 +Footprint for Mini-Circuits case HF1139 (https://ww2.minicircuits.com/case_style/HF1139.pdf) +Mini-Circuits HF1139 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_HF1139_LandPatternPL-230 +Footprint for Mini-Circuits case HF1139 (https://ww2.minicircuits.com/case_style/HF1139.pdf) following land pattern PL-230, including GND vias (https://ww2.minicircuits.com/pcb/98-pl230.pdf) +Mini-Circuits PL-230 +0 +37 +8 +RF_Mini-Circuits +Mini-Circuits_HQ1157 +Footprint for Mini-Circuits case HQ1157 (https://www.minicircuits.com/case_style/HQ1157.pdf) +Mini-Circuits HQ1157 +0 +14 +14 +RF_Mini-Circuits +Mini-Circuits_HZ1198 +Footprint for Mini-Circuits case HZ1198 (https://ww2.minicircuits.com/case_style/HZ1198.pdf) +Mini-Circuits HZ1198 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_HZ1198_LandPatternPL-247 +Footprint for Mini-Circuits cas HZ1198 (https://ww2.minicircuits.com/case_style/HZ1198.pdf) following land pattern PL-247, including GND-vias (https://www.minicircuits.com/pcb/98-pl247.pdf) +Mini-Circuits PL-247 HZ1198 +0 +40 +6 +RF_Mini-Circuits +Mini-Circuits_MMM168 +Footprint for Mini-Circuits case MMM168 (https://ww2.minicircuits.com/case_style/MMM168.pdf) +Mini-Circuits MMM168 +0 +4 +4 +RF_Mini-Circuits +Mini-Circuits_MMM168_LandPatternPL-225 +Footprint for Mini-Circuits case MMM168, Land pattern PL-225, vias included, (case drawing: https://ww2.minicircuits.com/case_style/MMM168.pdf, land pattern drawing: https://ww2.minicircuits.com/pcb/98-pl225.pdf) +pl-225 +0 +10 +4 +RF_Mini-Circuits +Mini-Circuits_QQQ130_ClockwisePinNumbering +Footprint for Mini-Circuits case QQQ130 (https://ww2.minicircuits.com/case_style/QQQ130.pdf) +Mini-Circuits QQQ130 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_QQQ130_LandPattern_PL-236_ClockwisePinNumbering +Footprint for Mini-Circuits case QQQ130 (https://ww2.minicircuits.com/case_style/QQQ130.pdf) following land pattern PL-236, including GND vias (https://ww2.minicircuits.com/pcb/98-pl236.pdf) +Mini-Circuits PL-236 +0 +14 +6 +RF_Mini-Circuits +Mini-Circuits_TT1224_ClockwisePinNumbering +Footprint for Mini-Circuits case TT1224 (https://ww2.minicircuits.com/case_style/TT1224.pdf) following land-pattern PL-258, including GND-vias (https://www.minicircuits.com/pcb/98-pl258.pdf) +Mini-Circuits TT1224 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_TT1224_LandPatternPL-258_ClockwisePinNumbering +Footprint for Mini-Circuits case TT1224 (https://ww2.minicircuits.com/case_style/TT1224.pdf) following land-pattern PL-258, including GND-vias (https://www.minicircuits.com/pcb/98-pl258.pdf) +PL-258 Mini-Circuits +0 +26 +6 +RF_Mini-Circuits +Mini-Circuits_TTT167 +Footprint for Mini-Circuits case TTT167 (https://ww2.minicircuits.com/case_style/TTT167.pdf) +Mini-Circuits TTT167 +0 +6 +6 +RF_Mini-Circuits +Mini-Circuits_TTT167_LandPatternPL-079 +Footprint for Mini-Circuits case TTT167 (Mini-Circuits_TTT167_LandPatternPL-079) following land pattern PL-079, including GND vias (https://ww2.minicircuits.com/pcb/98-pl079.pdf) +Mini-Circuits PL-079 +0 +36 +6 +RF_Mini-Circuits +Mini-Circuits_YY161 +Footprint for Mini-Circuits case YY161 (https://ww2.minicircuits.com/case_style/YY161.pdf) +Mini-Circuits YY161 +0 +8 +8 +RF_Mini-Circuits +Mini-Circuits_YY161_LandPatternPL-049 +Footprint for Mini-Circuits case YY161 (https://ww2.minicircuits.com/case_style/YY161.pdf) using land-pattern PL-049, including GND-connections and vias (https://ww2.minicircuits.com/pcb/98-pl049.pdf) +mini-circuits pl-049 +0 +36 +8 +RF_Module +Ai-Thinker-Ra-01-LoRa +Ai Thinker Ra-01 LoRa +LoRa Ra-01 +0 +16 +16 +RF_Module +Atmel_ATSAMR21G18-MR210UA_NoRFPads +http://ww1.microchip.com/downloads/en/devicedoc/atmel-42475-atsamr21g18-mr210ua_datasheet.pdf +module wireless zigbee 802.15.4 flash crypto ATSAMR21G18 AT45DB041E TECC508A U.Fi +0 +42 +42 +RF_Module +BLE112-A +Class 4 Bluetooth Module with on-board antenna +Bluetooth Module +0 +30 +30 +RF_Module +CMWX1ZZABZ +https://wireless.murata.com/RFM/data/type_abz.pdf +iot lora sigfox +0 +57 +57 +RF_Module +CYBLE-21Pin-10x10mm +Cypress EZ-BLE PRoC Module (Bluetooth Smart) 21 Pin Module +Cypress BT Bluetooth +0 +21 +21 +RF_Module +DWM1000 +IEEE802.15.4-2011 UWB +UWB Module +0 +24 +24 +RF_Module +DecaWave_DWM1001 +https://www.decawave.com/sites/default/files/dwm1001_datasheet.pdf +UWB module +0 +34 +34 +RF_Module +Digi_XBee_SMT +http://www.digi.com/resources/documentation/digidocs/pdfs/90002126.pdf http://ftp1.digi.com/support/documentation/90001020_F.pdf +Digi XBee SMT RF +0 +37 +37 +RF_Module +E18-MS1-PCB +http://www.cdebyte.com/en/downpdf.aspx?id=122 +Zigbee +0 +24 +24 +RF_Module +E73-2G4M04S +http://www.cdebyte.com/en/downpdf.aspx?id=243 +BLE BLE5 nRF52832 +0 +44 +44 +RF_Module +ESP-07 +Wi-Fi Module, http://wiki.ai-thinker.com/_media/esp8266/docs/a007ps01a2_esp-07_product_specification_v1.2.pdf +Wi-Fi Module +0 +16 +16 +RF_Module +ESP-12E +Wi-Fi Module, http://wiki.ai-thinker.com/_media/esp8266/docs/aithinker_esp_12f_datasheet_en.pdf +Wi-Fi Module +0 +22 +22 +RF_Module +ESP-WROOM-02 +http://espressif.com/sites/default/files/documentation/0c-esp-wroom-02_datasheet_en.pdf +ESP WROOM-02 espressif esp8266ex +0 +19 +19 +RF_Module +ESP32-S2-WROVER +ESP32-S2-WROVER(-I) 2.4 GHz Wi-Fi https://www.espressif.com/sites/default/files/documentation/esp32-s2-wroom_esp32-s2-wroom-i_datasheet_en.pdf +ESP32-S2 ESP32 WIFI +0 +43 +43 +RF_Module +ESP32-WROOM-32 +Single 2.4 GHz Wi-Fi and Bluetooth combo chip https://www.espressif.com/sites/default/files/documentation/esp32-wroom-32_datasheet_en.pdf +Single 2.4 GHz Wi-Fi and Bluetooth combo chip +0 +39 +39 +RF_Module +ESP32-WROOM-32U +Single 2.4 GHz Wi-Fi and Bluetooth combo chip with U.FL connector, https://www.espressif.com/sites/default/files/documentation/esp32-wroom-32d_esp32-wroom-32u_datasheet_en.pdf +Single 2.4 GHz Wi-Fi and Bluetooth combo chip +0 +39 +39 +RF_Module +Garmin_M8-35_9.8x14.0mm_Layout6x6_P1.5mm +D52M ANT SoC Module https://www.thisisant.com/assets/resources/D00001687_D52_Module_Datasheet.v.2.3_(Garmin).pdf +RF SoC Radio ANT Bluetooth BLE D52 nRF52 Garmin Canada Dynastream Nordic +0 +35 +35 +RF_Module +HOPERF_RFM9XW_SMD +Low Power Long Range Transceiver Module SMD-16 (https://www.hoperf.com/data/upload/portal/20181127/5bfcbea20e9ef.pdf) +LoRa Low Power Long Range Transceiver Module +0 +16 +16 +RF_Module +HOPERF_RFM9XW_THT +Low Power Long Range Transceiver Module THT-16 (https://www.hoperf.com/data/upload/portal/20181127/5bfcbea20e9ef.pdf) +Low Power Long Range Transceiver Module LoRa +0 +16 +16 +RF_Module +HOPERF_RFM69HW +Radio, RF, Module, http://www.hoperf.com/upload/rf/RFM69HW-V1.3.pdf +Radio RF Module +0 +16 +16 +RF_Module +IQRF_TRx2DA_KON-SIM-01 +8 pin SIM connector for IQRF TR-x2DA(T) modules, http://iqrf.org/weben/downloads.php?id=104 +IQRF_KON-SIM-01 IQRF_TRx2DA +0 +10 +8 +RF_Module +IQRF_TRx2D_KON-SIM-01 +8 pin SIM connector for IQRF TR-x2D(C)(T) modules, http://iqrf.org/weben/downloads.php?id=104 +IQRF_KON-SIM-01 IQRF_TRx2D IQRF_TRx2DC +0 +10 +8 +RF_Module +Laird_BL652 +Bluetooth v4.2 + NFC module +Bluetooth BLE NFC +0 +39 +39 +RF_Module +MOD-nRF8001 +BLE module, https://www.olimex.com/Products/Modules/RF/MOD-nRF8001/ +BLE module +0 +11 +11 +RF_Module +Microchip_RN4871 +Microchip RN4871 footprint +RN4871 BLE +0 +16 +16 +RF_Module +Modtronix_inAir9 +Modtronix Wireless SX1276 LoRa Module (http://modtronix.com/img/prod/imod/inair9/inair_dimensions.gif) +Modtronix LoRa inAir inAir9 SX1276 RF 915MHz 868MHz Wireless +0 +14 +14 +RF_Module +MonoWireless_TWE-L-WX +https://www.mono-wireless.com/jp/products/TWE-LITE/MW-PDS-TWELITE-JP.pdf +TWE-L-WX +0 +32 +32 +RF_Module +Particle_P1 +https://docs.particle.io/datasheets/p1-datasheet/ +Particle P1 +0 +75 +75 +RF_Module +RFDigital_RFD77101 +RFDigital RFD77101 Simblee +RFDigital RFD77101 Simblee +0 +48 +45 +RF_Module +RN42 +Class 2 Bluetooth Module with on-board antenna +Bluetooth Module +0 +36 +33 +RF_Module +RN42N +Class 2 Bluetooth Module without antenna +Bluetooth Module +0 +39 +36 +RF_Module +RN2483 +Low-Power Long Range LoRa Transceiver Module +rf module lora lorawan +0 +47 +47 +RF_Module +ST_SPBTLE +Bluetooth Low Energy Module +ble module st bluetooth +0 +11 +11 +RF_Module +TD1205 +https://github.com/Telecom-Design/Documentation_TD_RF_Module/blob/master/TD1205%20Datasheet.pdf +SIGFOX Module +0 +9 +9 +RF_Module +TD1208 +https://github.com/Telecom-Design/Documentation_TD_RF_Module/blob/master/TD1208%20Datasheet.pdf +SIGFOX Module +0 +25 +25 +RF_Module +Taiyo-Yuden_EYSGJNZWY +Taiyo Yuden NRF51822 Module Bluetooth https://www.yuden.co.jp/wireless_module/document/datareport2/en/TY_BLE_EYSGJNZ_DataReport_V1_9_20180530E.pdf +Taiyo Yuden NRF51822 Module Bluetooth +0 +30 +28 +RF_Module +ZETA-433-SO_SMD +RF transceiver SMD style https://www.rfsolutions.co.uk/downloads/1456219226DS-ZETA.pdf +RF transceiver SMD style +0 +12 +12 +RF_Module +ZETA-433-SO_THT +RF transceiver THT style https://www.rfsolutions.co.uk/downloads/1456219226DS-ZETA.pdf +RF transceiver SMD style +0 +12 +12 +RF_Module +nRF24L01_Breakout +nRF24L01 breakout board +nRF24L01 adapter breakout +0 +8 +8 +RF_Shielding +Laird_Technologies_97-2002_25.40x25.40mm +Laird Technologies 97-2002 EZ PEEL Shielding Cabinet One Piece SMD 25.40x25.40mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +8 +1 +RF_Shielding +Laird_Technologies_97-2003_12.70x13.37mm +Laird Technologies 97-2003 EZ PEEL Shielding Cabinet One Piece SMD 12.70x13.37mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +8 +1 +RF_Shielding +Laird_Technologies_BMI-S-101_13.66x12.70mm +Laird Technologies BMI-S-101 Shielding Cabinet One Piece SMD 13.66x12.70mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-102_16.50x16.50mm +Laird Technologies BMI-S-102 Shielding Cabinet One Piece SMD 16.50x16.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-103_26.21x26.21mm +Laird Technologies BMI-S-103 Shielding Cabinet One Piece SMD 26.21x26.21mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +24 +1 +RF_Shielding +Laird_Technologies_BMI-S-104_32.00x32.00mm +Laird Technologies BMI-S-104 Shielding Cabinet One Piece SMD 32.00x32.00mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-105_38.10x25.40mm +Laird Technologies BMI-S-105 Shielding Cabinet One Piece SMD 38.10x25.40mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-106_36.83x33.68mm +Laird Technologies BMI-S-106 Shielding Cabinet One Piece SMD 36.83x33.68mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-107_44.37x44.37mm +Laird Technologies BMI-S-107 Shielding Cabinet One Piece SMD 44.37x44.37mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +36 +1 +RF_Shielding +Laird_Technologies_BMI-S-201-F_13.66x12.70mm +Laird Technologies BMI-S-201-F Shielding Cabinet Two Piece SMD 13.66x12.70mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-202-F_16.50x16.50mm +Laird Technologies BMI-S-202-F Shielding Cabinet Two Piece SMD 16.50x16.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +16 +1 +RF_Shielding +Laird_Technologies_BMI-S-203-F_26.21x26.21mm +Laird Technologies BMI-S-203-F Shielding Cabinet Two Piece SMD 26.21x26.21mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +24 +1 +RF_Shielding +Laird_Technologies_BMI-S-204-F_32.00x32.00mm +Laird Technologies BMI-S-204-F Shielding Cabinet Two Piece SMD 32.00x32.00mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-205-F_38.10x25.40mm +Laird Technologies BMI-S-205-F Shielding Cabinet Two Piece SMD 38.10x25.40mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-206-F_36.83x33.68mm +Laird Technologies BMI-S-206-F Shielding Cabinet Two Piece SMD 36.83x33.68mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +28 +1 +RF_Shielding +Laird_Technologies_BMI-S-207-F_44.37x44.37mm +Laird Technologies BMI-S-207-F Shielding Cabinet Two Piece SMD 44.37x44.37mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +36 +1 +RF_Shielding +Laird_Technologies_BMI-S-208-F_39.60x39.60mm +Laird Technologies BMI-S-208-F Shielding Cabinet Two Piece SMD 39.60x39.60mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +32 +1 +RF_Shielding +Laird_Technologies_BMI-S-209-F_29.36x18.50mm +Laird Technologies BMI-S-209-F Shielding Cabinet Two Piece SMD 29.36x18.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +20 +1 +RF_Shielding +Laird_Technologies_BMI-S-210-F_44.00x30.50mm +Laird Technologies BMI-S-210-F Shielding Cabinet Two Piece SMD 44.00x30.50mm (https://assets.lairdtech.com/home/brandworld/files/Board%20Level%20Shields%20Catalog%20Download.pdf) +Shielding Cabinet +0 +32 +1 +RF_Shielding +Laird_Technologies_BMI-S-230-F_50.8x38.1mm +Laird Technologies BMI-S-230-F Shielding Cabinet Two Piece SMD 50.8x38.1mm +Shielding Cabinet +0 +36 +1 +RF_Shielding +Wuerth_36103205_20x20mm +WE-SHC Shielding Cabinet SMD 20x20mm +Shielding Cabinet +0 +20 +1 +RF_Shielding +Wuerth_36103255_25x25mm +WE-SHC Shielding Cabinet SMD 25x25mm +Shielding Cabinet +0 +24 +1 +RF_Shielding +Wuerth_36103305_30x30mm +WE-SHC Shielding Cabinet SMD 30x30mm +Shielding Cabinet +0 +28 +1 +RF_Shielding +Wuerth_36103505_50x50mm +WE-SHC Shielding Cabinet SMD 50x50mm +Shielding Cabinet +0 +44 +1 +RF_Shielding +Wuerth_36103605_60x60mm +WE-SHC Shielding Cabinet SMD 60x60mm +Shielding Cabinet +0 +52 +1 +RF_Shielding +Wuerth_36503205_20x20mm +WE-SHC Shielding Cabinet THT 21x21mm +Shielding Cabinet +0 +16 +1 +RF_Shielding +Wuerth_36503255_25x25mm +WE-SHC Shielding Cabinet THT 26x26mm +Shielding Cabinet +0 +20 +1 +RF_Shielding +Wuerth_36503305_30x30mm +WE-SHC Shielding Cabinet THT 31x31mm +Shielding Cabinet +0 +24 +1 +RF_Shielding +Wuerth_36503505_50x50mm +WE-SHC Shielding Cabinet THT 51x51mm +Shielding Cabinet +0 +40 +1 +RF_Shielding +Wuerth_36503605_60x60mm +WE-SHC Shielding Cabinet THT 61x61mm +Shielding Cabinet +0 +48 +1 +RF_WiFi +USR-C322 +https://www.usriot.com/download/WIFI/USR-C322-Hardware-Manual_V1.2.01.pdf +WiFi IEEE802.11 b/g/n +0 +44 +44 +Relay_SMD +Relay_DPDT_AXICOM_IMSeries_JLeg +http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7F108-98001%7FW5%7Fpdf%7FEnglish%7FENG_SS_108-98001_W5.pdf +AXICOM IM-Series Relay J JLeg +0 +8 +8 +Relay_SMD +Relay_DPDT_FRT5_SMD +IM Signal Relay DPDT FRT5 narrow footprint, SMD version of package +Relay DPDT IM-relay FRT5 +0 +10 +10 +Relay_SMD +Relay_DPDT_Kemet_EE2_NU +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double coil latching surface mount SMD +0 +8 +8 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUH +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double coil latching surface mount SMD +0 +8 +8 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUH_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching surface mount SMD +0 +10 +10 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUX_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching surface mount SMD +0 +10 +10 +Relay_SMD +Relay_DPDT_Kemet_EE2_NUX_NKX +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double coil latching surface mount SMD +0 +8 +8 +Relay_SMD +Relay_DPDT_Kemet_EE2_NU_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching surface mount SMD +0 +10 +10 +Relay_SMD +Relay_DPDT_Omron_G6H-2F +package for Omron G6H-2F relais, see http://cdn-reichelt.de/documents/datenblatt/C300/G6H%23OMR.pdf +Omron G6H-2F relais +0 +10 +10 +Relay_SMD +Relay_DPDT_Omron_G6K-2F +Omron G6K-2F relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2F relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6K-2F-Y +Omron G6K-2F-Y relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2F-Y relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6K-2G +Omron G6K-2G relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2G relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6K-2G-Y +Omron G6K-2G-Y relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2G-Y relay +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6S-2F +Relay Omron G6S-2F, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6S-2F +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6S-2G +Relay Omron G6S-2G, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6S-2G +0 +8 +8 +Relay_SMD +Relay_DPDT_Omron_G6SK-2F +Relay Omron G6SK-2F, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6SK-2F +0 +10 +10 +Relay_SMD +Relay_DPDT_Omron_G6SK-2G +Relay Omron G6SK-2G, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6SK-2G +0 +10 +10 +Relay_SMD +Relay_Fujitsu_FTR-B3S +https://www.fujitsu.com/downloads/MICRO/fcai/relays/ftr-b3.pdf +Fujitsh FTR B3S B3SA Relay J JLeg +0 +8 +8 +Relay_SMD +Relay_SPDT_AXICOM_HF3Series_50ohms_Pitch1.27mm +hiqsdr.com/images/3/3e/Axicom-HF3.pdf +AXICOM HF3-Series Relay Pitch 1.27mm 50ohms +0 +16 +16 +Relay_SMD +Relay_SPDT_AXICOM_HF3Series_75ohms_Pitch1.27mm +hiqsdr.com/images/3/3e/Axicom-HF3.pdf +AXICOM HF3-Series Relay Pitch 1.27mm 75ohm +0 +16 +16 +Relay_THT +Relay_1-Form-A_Schrack-RYII_RM5mm +Relay, 1-Form-A, Schrack-RYII, RM5mm, SPST-NO +Relay 1-Form-A Schrack-RYII RM5mm SPST-NO +0 +4 +4 +Relay_THT +Relay_1-Form-B_Schrack-RYII_RM5mm +Relay, 1-Form-B, Schrack-RYII, RM5mm, SPST-NC +Relay 1-Form-B Schrack-RYII RM5mm SPST-NC +0 +4 +4 +Relay_THT +Relay_1-Form-C_Schrack-RYII_RM3.2mm +Relay, 1-Form-C, Schrack-RYII, RM3.2mm, SPDT +Relay 1-Form-C Schrack-RYII RM3.2mm SPDT +0 +5 +5 +Relay_THT +Relay_1P1T_NO_10x24x18.8mm_Panasonic_ADW11xxxxW_THT +Panasonic Relay SPST 10mm 24mm, https://www.panasonic-electric-works.com/pew/es/downloads/ds_dw_hl_en.pdf +Panasonic Relay SPST +0 +4 +4 +Relay_THT +Relay_DPDT_AXICOM_IMSeries_Pitch3.2mm +AXICOM IM-Series Relays, DPDR, Pitch 3.2mm, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7F108-98001%7FV%7Fpdf%7FEnglish%7FENG_SS_108-98001_V_IM_0614_v1.pdf%7F4-1462039-1 +AXICOM IM-Series Relay DPDR Pitch 3.2mm +0 +8 +8 +Relay_THT +Relay_DPDT_AXICOM_IMSeries_Pitch5.08mm +AXICOM IM-Series Relays, DPDR, Pitch 5.08 +AXICOM IM-Series Relay DPDR Pitch 5.08 +0 +8 +8 +Relay_THT +Relay_DPDT_FRT5 +IM Signal Relay DPDT FRT5 narrow footprint +Relay DPDT IM-relay FRT5 +0 +10 +10 +Relay_THT +Relay_DPDT_Finder_30.22 +Finder 32.21-x000 Relay, DPDT, https://gfinder.findernet.com/public/attachments/30/EN/S30EN.pdf +AXICOM IM-Series Relay SPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Finder_40.52 +Relay DPDT Finder 40.52, Pitch 5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.52 Pitch 5mm +0 +8 +8 +Relay_THT +Relay_DPDT_Fujitsu_FTR-F1C +https://www.fujitsu.com/downloads/MICRO/fcai/relays/ftr-f1.pdf +relay dpdt fujitsu tht +0 +8 +8 +Relay_THT +Relay_DPDT_Kemet_EC2 +Kemet signal relay, DPDT, non-latching, single coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT non single coil latching through hole THT +0 +8 +8 +Relay_THT +Relay_DPDT_Kemet_EC2_DoubleCoil +Kemet signal relay, DPDT, double coil latching, https://content.kemet.com/datasheets/KEM_R7002_EC2_EE2.pdf +Kemet EC2 signal relay DPDT double dual coil latching through hole THT +0 +10 +10 +Relay_THT +Relay_DPDT_Omron_G2RL +Omron Relay DPDT, https://omronfs.omron.com/en_US/ecb/products/pdf/en-g2rl.pdf +Omron Relay DPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G5V-2 +http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5v2.pdf +Omron G5V-2 Relay DPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6H-2 +Omron relay G6H-2, see http://cdn-reichelt.de/documents/datenblatt/C300/G6H%23OMR.pdf +Omron relay G6H-2 +0 +10 +10 +Relay_THT +Relay_DPDT_Omron_G6K-2P +Omron G6K-2P relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2P relay +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6K-2P-Y +Omron G6K-2P-Y relay package http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6k.pdf +Omron G6K-2P-Y relay +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6S-2 +Relay Omron G6S-2, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6S-2 +0 +8 +8 +Relay_THT +Relay_DPDT_Omron_G6SK-2 +Relay Omron G6SK-2, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g6s.pdf +Relay Omron G6SK-2 +0 +10 +10 +Relay_THT +Relay_DPDT_Panasonic_JW2 +Panasonic Relay DPDT, http://www3.panasonic.biz/ac/e_download/control/relay/power/catalog/mech_eng_jw.pdf?via=ok +Panasonic Relay DPDT +0 +8 +8 +Relay_THT +Relay_DPDT_Schrack-RT2-FormC-Dual-Coil_RM5mm +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Form C http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FRT2_bistable%7F1116%7Fpdf%7FEnglish%7FENG_DS_RT2_bistable_1116.pdf%7F1-1415537-8 +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Relay +0 +9 +9 +Relay_THT +Relay_DPDT_Schrack-RT2-FormC_RM5mm +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Form C http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=RT2_reflow&DocType=DS&DocLang=EN +Relay DPDT Schrack-RT2 RM5mm 16A 250V AC Relay +0 +8 +8 +Relay_THT +Relay_DPST_Fujitsu_FTR-F1A +https://www.fujitsu.com/downloads/MICRO/fcai/relays/ftr-f1.pdf +relay dpst fujitsu tht +0 +6 +6 +Relay_THT +Relay_DPST_Schrack-RT2-FormA_RM5mm +Relay DPST Schrack-RT2 RM5mm 16A 250V AC Form A http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=RT2_reflow&DocType=DS&DocLang=EN +Relay DPST Schrack-RT2 RM5mm 16A 250V AC Relay +0 +6 +6 +Relay_THT +Relay_SPDT_Finder_32.21-x000 +Finder 32.21-x000 Relay, SPDT, https://gfinder.findernet.com/assets/Series/355/S32EN.pdf +AXICOM IM-Series Relay SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_34.51_Horizontal +Relay SPDT, Finder Type34.51, horizontal form, see https://gfinder.findernet.com/public/attachments/34/EN/S34USAEN.pdf +Relay SPDT Finder +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_34.51_Vertical +Relay SPDT, Finder Type34.51, vertical/standing form, see https://gfinder.findernet.com/public/attachments/34/EN/S34USAEN.pdf +Relay SPDT Finder +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_36.11 +FINDER 36.11, SPDT relay, 10A, https://gfinder.findernet.com/public/attachments/36/EN/S36EN.pdf +spdt relay +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.11 +Relay SPDT Finder 40.11, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay SPDT Finder 40.11 +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.31 +Relay DPDT Finder 40.31, Pitch 3.5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.31 Pitch 3.5mm +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.41 +Relay DPDT Finder 40.41, Pitch 3.5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.41 Pitch 3.5mm +0 +5 +5 +Relay_THT +Relay_SPDT_Finder_40.51 +Relay DPDT Finder 40.51, Pitch 5mm/7.5mm, https://www.finder-relais.net/de/finder-relais-serie-40.pdf +Relay DPDT Finder 40.51 Pitch 5mm +0 +5 +5 +Relay_THT +Relay_SPDT_HJR-4102 +IM Signal Relay SPDT HJR-4102 +Relay SPDT IM-relay HJR-4102 +0 +6 +6 +Relay_THT +Relay_SPDT_HsinDa_Y14 +http://www.hsinda.com.cn/en/ProductShow.asp?ID=208 +Relay Y14 +0 +6 +6 +Relay_THT +Relay_SPDT_Omron-G5LE-1 +Omron Relay SPDT, http://www.omron.com/ecb/products/pdf/en-g5le.pdf +Omron Relay SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_Omron-G5Q-1 +Relay SPDT Omron Serie G5Q, http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5q.pdf +Relay SPDT Omron Serie G5Q +0 +5 +5 +Relay_THT +Relay_SPDT_Omron_G5V-1 +Relay Omron G5V-1, see http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5v_1.pdf +Relay Omron G5V-1 +0 +6 +6 +Relay_THT +Relay_SPDT_Omron_G6E +Relay SPDT Omron Serie G6E +Relay SPDT Omron Serie G6E 1x um +0 +5 +5 +Relay_THT +Relay_SPDT_Omron_G6EK +Relay SPDT Omron Serie G6EK, see http://www.logosfoundation.org/instrum_gwr/pi/Omron_G6E_134P.pdf +Relay SPDT Omron Serie G6EK +0 +6 +6 +Relay_THT +Relay_SPDT_Panasonic_JW1_FormC +Panasonic Relay SPDT, http://www3.panasonic.biz/ac/e_download/control/relay/power/catalog/mech_eng_jw.pdf?via=ok +Panasonic Relay SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_PotterBrumfield_T9AP5D52_12V30A +Relay SPDT Potter&Brumfield T9AP5D52 12V 30A 1xUn Connector Fast ON Only Dummy for Space NO Pads +Relay SPDT Potter&Brumfield T9AP5D52 12V 30A 1xUm Connector Fast ON Flachsteckeranschluss Only Dummy for Space NO Pads +0 +0 +0 +Relay_THT +Relay_SPDT_RAYEX-L90 +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90 SPDT +0 +6 +6 +Relay_THT +Relay_SPDT_RAYEX-L90S +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90S SPDT +0 +5 +5 +Relay_THT +Relay_SPDT_SANYOU_SRD_Series_Form_C +relay Sanyou SRD series Form C http://www.sanyourelay.ca/public/products/pdf/SRD.pdf +relay Sanyu SRD form C +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RP-II-1-16A-FormC_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Form C http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Relay +0 +8 +5 +Relay_THT +Relay_SPDT_Schrack-RP-II-1-FormC_RM3.5mm +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RP-II-1-FormC_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RT1-16A-FormC_RM5mm +Relay SPST Schrack-RT1 RM5mm 16A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM5mm 16A 250V AC Relay +0 +8 +5 +Relay_THT +Relay_SPDT_Schrack-RT1-FormC_RM3.5mm +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_Schrack-RT1-FormC_RM5mm +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Relay +0 +5 +5 +Relay_THT +Relay_SPDT_StandexMeder_SIL_Form1C +Standex-Meder SIL-relais, Form 1C, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_SIL.pdf +Standex Meder SIL reed relais +0 +5 +5 +Relay_THT +Relay_SPST_Finder_32.21-x300 +Finder 32.21-x300 Relay, SPST, https://gfinder.findernet.com/assets/Series/355/S32EN.pdf +Finder 32.21-x300 Relay SPST +0 +4 +4 +Relay_THT +Relay_SPST_Omron-G5Q-1A +Relay SPST-NO Omron Serie G5Q, http://omronfs.omron.com/en_US/ecb/products/pdf/en-g5q.pdf +Relay SPST-NO Omron Serie G5Q +0 +4 +4 +Relay_THT +Relay_SPST_Panasonic_JW1_FormA +Panasonic Relay SPST, http://www3.panasonic.biz/ac/e_download/control/relay/power/catalog/mech_eng_jw.pdf?via=ok +Panasonic Relay SPST +0 +4 +4 +Relay_THT +Relay_SPST_PotterBrumfield_T9AP1D52_12V30A +Relay SPST Potter&Brumfield T9AP1D52 12V 30A 1xEin Connector Fast ON Only Dummy for Space NO Pads +Relau SPST Potter&Brumfield T9AP1D52 12V 30A 1xEin Connector Fast ON Flachsteckeranschluss Only Dummy for Space NO Pads +0 +0 +0 +Relay_THT +Relay_SPST_RAYEX-L90A +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90A SPST NO +0 +5 +5 +Relay_THT +Relay_SPST_RAYEX-L90AS +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90AS SPST NO +0 +4 +4 +Relay_THT +Relay_SPST_RAYEX-L90B +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90B SPST NC +0 +5 +5 +Relay_THT +Relay_SPST_RAYEX-L90BS +https://a3.sofastcdn.com/attachment/7jioKBjnRiiSrjrjknRiwS77gwbf3zmp/L90-SERIES.pdf +Relay RAYEX L90BS SPST NC +0 +4 +4 +Relay_THT +Relay_SPST_SANYOU_SRD_Series_Form_A +relay Sanyou SRD series Form A http://www.sanyourelay.ca/public/products/pdf/SRD.pdf +relay Sanyu SRD form A +0 +4 +4 +Relay_THT +Relay_SPST_SANYOU_SRD_Series_Form_B +relay Sanyou SRD series Form B opener http://www.sanyourelay.ca/public/products/pdf/SRD.pdf +relay Sanyu SRD form B opener +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RP-II-1-16A-FormA_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Form A http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 16A 250V AC Relay +0 +6 +4 +Relay_THT +Relay_SPST_Schrack-RP-II-1-FormA_RM3.5mm +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Form A +Relay SPST Schrack-RP-II/1 RM3.5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RP-II-1-FormA_RM5mm +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Form A http://image.schrack.com/datenblaetter/h_rp810012-b.pdf +Relay SPST Schrack-RP-II/1 RM5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RP3SL-1coil_RM5mm +Relay SPST Schrack-RP3SL, 1-coil-version, RM5mm 16A 250V AC Form A http://www.alliedelec.com/m/d/543c6bed18bf23a83ae5238947033ee0.pdf +Relay SPST Schrack-RP3SL RM5mm 16A 250V AC Relay +0 +6 +4 +Relay_THT +Relay_SPST_Schrack-RP3SL_RM5mm +Relay SPST Schrack-RP3SL RM5mm 16A 250V AC Form A http://www.alliedelec.com/m/d/543c6bed18bf23a83ae5238947033ee0.pdf +Relay SPST Schrack-RP3SL RM5mm 16A 250V AC Relay +0 +7 +5 +Relay_THT +Relay_SPST_Schrack-RT1-16A-FormA_RM5mm +Relay SPST Schrack-RT2 RM5mm 16A 250V AC Form C http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=RT2_reflow&DocType=DS&DocLang=EN +Relay SPST Schrack-RT2 RM5mm 16A 250V AC Relay +0 +6 +4 +Relay_THT +Relay_SPST_Schrack-RT1-FormA_RM3.5mm +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Form A +Relay SPST Schrack-RT1 RM3.5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_Schrack-RT1-FormA_RM5mm +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Form C http://image.schrack.com/datenblaetter/h_rt114012--_de.pdf +Relay SPST Schrack-RT1 RM5mm 8A 250V AC Relay +0 +4 +4 +Relay_THT +Relay_SPST_StandexMeder_MS_Form1AB +Standex-Meder MS SIL-relais, Form 1A/1B, see https://standexelectronics.com/de/produkte/ms-reed-relais/ +Standex Meder MS SIL reed relais +0 +4 +4 +Relay_THT +Relay_SPST_StandexMeder_SIL_Form1A +Standex-Meder SIL-relais, Form 1A, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_SIL.pdf +Standex Meder SIL reed relais +0 +4 +4 +Relay_THT +Relay_SPST_StandexMeder_SIL_Form1B +Standex-Meder SIL-relais, Form 1B, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_SIL.pdf +Standex Meder SIL reed relais +0 +4 +4 +Relay_THT +Relay_SPST_TE_PCH-1xxx2M +Miniature PCB Relay, PCH Series, 1 Form A (NO), SPST http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Data+Sheet%7FPCH_series_relay_data_sheet_E%7F1215%7Fpdf%7FEnglish%7FENG_DS_PCH_series_relay_data_sheet_E_1215.pdf +Relay SPST NO +0 +4 +4 +Relay_THT +Relay_SPST_TE_PCN-1xxD3MHZ +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1461491%7FG2%7Fpdf%7FEnglish%7FENG_CD_1461491_G2.pdf%7F3-1461491-0 +SPST relay slim +0 +4 +4 +Relay_THT +Relay_Socket_DPDT_Finder_96.12 +https://gfinder.findernet.com/public/attachments/56/DE/S56DE.pdf +Relay socket DPDT Finder 96.12 56.32 +0 +8 +8 +Relay_THT +Relay_StandexMeder_DIP_HighProfile +package for Standex Meder DIP reed relay series, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_DIP.pdf +DIL DIP PDIP 2.54mm 7.62mm 300mil reed relay +0 +8 +8 +Relay_THT +Relay_StandexMeder_DIP_LowProfile +package for Standex Meder DIP reed relay series, see https://standexelectronics.com/wp-content/uploads/datasheet_reed_relay_DIP.pdf +DIL DIP PDIP 2.54mm 7.62mm 300mil reed relay +0 +8 +8 +Relay_THT +Relay_StandexMeder_UMS +Standex-Meder SIL-relais, UMS, see http://cdn-reichelt.de/documents/datenblatt/C300/UMS05_1A80_75L_DB.pdf +Standex Meder SIL reed relais +0 +4 +4 +Resistor_SMD +R_0201_0603Metric +Resistor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +resistor +0 +4 +2 +Resistor_SMD +R_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Resistor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +4 +2 +Resistor_SMD +R_0402_1005Metric +Resistor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0402_1005Metric_Pad0.72x0.64mm_HandSolder +Resistor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0603_1608Metric +Resistor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0603_1608Metric_Pad0.98x0.95mm_HandSolder +Resistor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0612_1632Metric +Resistor SMD 0612 (1632 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0612_1632Metric_Pad1.18x3.40mm_HandSolder +Resistor SMD 0612 (1632 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0805_2012Metric +Resistor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0805_2012Metric_Pad1.20x1.40mm_HandSolder +Resistor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_0815_2038Metric +Resistor SMD 0815 (2038 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.susumu.co.jp/common/pdf/n_catalog_partition07_en.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_0815_2038Metric_Pad1.20x4.05mm_HandSolder +Resistor SMD 0815 (2038 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.susumu.co.jp/common/pdf/n_catalog_partition07_en.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_01005_0402Metric +Resistor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +resistor +0 +4 +2 +Resistor_SMD +R_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Resistor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +4 +2 +Resistor_SMD +R_1020_2550Metric +Resistor SMD 1020 (2550 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1020_2550Metric_Pad1.33x5.20mm_HandSolder +Resistor SMD 1020 (2550 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20019/rcwe.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1206_3216Metric +Resistor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1206_3216Metric_Pad1.30x1.75mm_HandSolder +Resistor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1210_3225Metric +Resistor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1210_3225Metric_Pad1.30x2.65mm_HandSolder +Resistor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1218_3246Metric +Resistor SMD 1218 (3246 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20035/dcrcwe3.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1218_3246Metric_Pad1.22x4.75mm_HandSolder +Resistor SMD 1218 (3246 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20035/dcrcwe3.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_1812_4532Metric +Resistor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_1812_4532Metric_Pad1.30x3.40mm_HandSolder +Resistor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.nikhef.nl/pub/departments/mt/projects/detectorR_D/dtddice/ERJ2G.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_2010_5025Metric +Resistor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_2010_5025Metric_Pad1.40x2.65mm_HandSolder +Resistor SMD 2010 (5025 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_2512_6332Metric +Resistor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_2512_6332Metric_Pad1.40x3.35mm_HandSolder +Resistor SMD 2512 (6332 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_2816_7142Metric +Resistor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_2816_7142Metric_Pad3.20x4.45mm_HandSolder +Resistor SMD 2816 (7142 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: https://www.vishay.com/docs/30100/wsl.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_4020_10251Metric +Resistor SMD 4020 (10251 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://datasheet.octopart.com/HVC0603T5004FET-Ohmite-datasheet-26699797.pdf), generated with kicad-footprint-generator +resistor +0 +2 +2 +Resistor_SMD +R_4020_10251Metric_Pad1.65x5.30mm_HandSolder +Resistor SMD 4020 (10251 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://datasheet.octopart.com/HVC0603T5004FET-Ohmite-datasheet-26699797.pdf), generated with kicad-footprint-generator +resistor handsolder +0 +2 +2 +Resistor_SMD +R_Array_Concave_2x0603 +Thick Film Chip Resistor Array, Wave soldering, Vishay CRA06P (see cra06p.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Concave_4x0402 +Thick Film Chip Resistor Array, Wave soldering, Vishay CRA04P (see cra04p.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Concave_4x0603 +Thick Film Chip Resistor Array, Wave soldering, Vishay CRA06P (see cra06p.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_2x0402 +Chip Resistor Network, ROHM MNR02 (see mnr_g.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_2x0603 +Chip Resistor Network, ROHM MNR12 (see mnr_g.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_2x0606 +Precision Thin Film Chip Resistor Array, VISHAY (see http://www.vishay.com/docs/28770/acasat.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_2x1206 +Chip Resistor Network, ROHM MNR32 (see mnr_g.pdf) +resistor array +0 +4 +4 +Resistor_SMD +R_Array_Convex_4x0402 +Chip Resistor Network, ROHM MNR04 (see mnr_g.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_4x0603 +Chip Resistor Network, ROHM MNR14 (see mnr_g.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_4x0612 +Precision Thin Film Chip Resistor Array, VISHAY (see http://www.vishay.com/docs/28770/acasat.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_4x1206 +Chip Resistor Network, ROHM MNR34 (see mnr_g.pdf) +resistor array +0 +8 +8 +Resistor_SMD +R_Array_Convex_5x0603 +Chip Resistor Network, ROHM MNR15 (see mnr_g.pdf) +resistor array +0 +10 +10 +Resistor_SMD +R_Array_Convex_5x1206 +Chip Resistor Network, ROHM MNR35 (see mnr_g.pdf) +resistor array +0 +10 +10 +Resistor_SMD +R_Array_Convex_8x0602 +Chip Resistor Network, ROHM MNR18 (see mnr_g.pdf) +resistor array +0 +16 +16 +Resistor_SMD +R_Cat16-2 +SMT resistor net, Bourns CAT16 series, 2 way +SMT resistor net Bourns CAT16 series 2 way +0 +4 +4 +Resistor_SMD +R_Cat16-4 +SMT resistor net, Bourns CAT16 series, 4 way +SMT resistor net Bourns CAT16 series 4 way +0 +8 +8 +Resistor_SMD +R_Cat16-8 +SMT resistor net, Bourns CAT16 series, 8 way +SMT resistor net Bourns CAT16 series 8 way +0 +16 +16 +Resistor_SMD +R_MELF_MMB-0207 +Resistor, MELF, MMB-0207, http://www.vishay.com/docs/28713/melfprof.pdf +MELF Resistor +0 +2 +2 +Resistor_SMD +R_MicroMELF_MMU-0102 +Resistor, MicroMELF, MMU-0102, http://www.vishay.com/docs/28713/melfprof.pdf +MicroMELF Resistor +0 +2 +2 +Resistor_SMD +R_MiniMELF_MMA-0204 +Resistor, MiniMELF, MMA-0204, http://www.vishay.com/docs/28713/melfprof.pdf +MiniMELF Resistor +0 +2 +2 +Resistor_SMD +R_Shunt_Ohmite_LVK12 +4 contact shunt resistor +shunt resistor 4 contacts +0 +4 +4 +Resistor_SMD +R_Shunt_Ohmite_LVK20 +4 contacts shunt resistor, https://www.ohmite.com/assets/docs/res_lvk.pdf +4 contacts resistor smd +0 +4 +4 +Resistor_SMD +R_Shunt_Ohmite_LVK24 +4 contacts shunt resistor,https://www.ohmite.com/assets/docs/res_lvk.pdf +4 contacts resistor smd +0 +4 +4 +Resistor_SMD +R_Shunt_Ohmite_LVK25 +4 contacts shunt resistor,https://www.ohmite.com/assets/docs/res_lvk.pdf +4 contacts resistor smd +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSK2512_6332Metric_T1.19mm +Shunt Resistor SMD 2512 (6332 Metric), 2.6mm thick, Vishay WKS2512, Terminal length (T) 1.19mm, 5 to 200 milli Ohm (http://http://www.vishay.com/docs/30108/wsk.pdf) +resistor shunt WSK2512 +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSK2512_6332Metric_T2.21mm +Shunt Resistor SMD 2512 (6332 Metric), 2.6mm thick, Vishay WKS2512, Terminal length (T) 2.21mm, 1 to 4.9 milli Ohm (http://http://www.vishay.com/docs/30108/wsk.pdf) +resistor shunt WSK2512 +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSK2512_6332Metric_T2.66mm +Shunt Resistor SMD 2512 (6332 Metric), 2.6mm thick, Vishay WKS2512, Terminal length (T) 2.66mm, 0.5 to 0.99 milli Ohm (http://http://www.vishay.com/docs/30108/wsk.pdf) +resistor shunt WSK2512 +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSKW0612 +https://www.vishay.com/docs/30332/wskw0612.pdf +4-Terminal SMD Shunt +0 +4 +4 +Resistor_SMD +R_Shunt_Vishay_WSR2_WSR3 +Power Metal Strip Resistors 0.005 to 0.2, https://www.vishay.com/docs/30101/wsr.pdf +SMD Shunt Resistor +0 +2 +2 +Resistor_SMD +R_Shunt_Vishay_WSR2_WSR3_KelvinConnection +Power Metal Strip Resistors 0.005 to 0.2, https://www.vishay.com/docs/30101/wsr.pdf +SMD Shunt Resistor +0 +4 +2 +Resistor_THT +R_Array_SIP4 +4-pin Resistor SIP pack +R +0 +4 +4 +Resistor_THT +R_Array_SIP5 +5-pin Resistor SIP pack +R +0 +5 +5 +Resistor_THT +R_Array_SIP6 +6-pin Resistor SIP pack +R +0 +6 +6 +Resistor_THT +R_Array_SIP7 +7-pin Resistor SIP pack +R +0 +7 +7 +Resistor_THT +R_Array_SIP8 +8-pin Resistor SIP pack +R +0 +8 +8 +Resistor_THT +R_Array_SIP9 +9-pin Resistor SIP pack +R +0 +9 +9 +Resistor_THT +R_Array_SIP10 +10-pin Resistor SIP pack +R +0 +10 +10 +Resistor_THT +R_Array_SIP11 +11-pin Resistor SIP pack +R +0 +11 +11 +Resistor_THT +R_Array_SIP12 +12-pin Resistor SIP pack +R +0 +12 +12 +Resistor_THT +R_Array_SIP13 +13-pin Resistor SIP pack +R +0 +13 +13 +Resistor_THT +R_Array_SIP14 +14-pin Resistor SIP pack +R +0 +14 +14 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P1.90mm_Vertical +Resistor, Axial_DIN0204 series, Axial, Vertical, pin pitch=1.9mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Vertical pin pitch 1.9mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P2.54mm_Vertical +Resistor, Axial_DIN0204 series, Axial, Vertical, pin pitch=2.54mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Vertical pin pitch 2.54mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P5.08mm_Horizontal +Resistor, Axial_DIN0204 series, Axial, Horizontal, pin pitch=5.08mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Horizontal pin pitch 5.08mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P5.08mm_Vertical +Resistor, Axial_DIN0204 series, Axial, Vertical, pin pitch=5.08mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Vertical pin pitch 5.08mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0204_L3.6mm_D1.6mm_P7.62mm_Horizontal +Resistor, Axial_DIN0204 series, Axial, Horizontal, pin pitch=7.62mm, 0.167W, length*diameter=3.6*1.6mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0204 series Axial Horizontal pin pitch 7.62mm 0.167W length 3.6mm diameter 1.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P2.54mm_Vertical +Resistor, Axial_DIN0207 series, Axial, Vertical, pin pitch=2.54mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Vertical pin pitch 2.54mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P5.08mm_Vertical +Resistor, Axial_DIN0207 series, Axial, Vertical, pin pitch=5.08mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Vertical pin pitch 5.08mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P7.62mm_Horizontal +Resistor, Axial_DIN0207 series, Axial, Horizontal, pin pitch=7.62mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Horizontal pin pitch 7.62mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal +Resistor, Axial_DIN0207 series, Axial, Horizontal, pin pitch=10.16mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Horizontal pin pitch 10.16mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0207_L6.3mm_D2.5mm_P15.24mm_Horizontal +Resistor, Axial_DIN0207 series, Axial, Horizontal, pin pitch=15.24mm, 0.25W = 1/4W, length*diameter=6.3*2.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0207 series Axial Horizontal pin pitch 15.24mm 0.25W = 1/4W length 6.3mm diameter 2.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P2.54mm_Vertical +Resistor, Axial_DIN0309 series, Axial, Vertical, pin pitch=2.54mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Vertical pin pitch 2.54mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P5.08mm_Vertical +Resistor, Axial_DIN0309 series, Axial, Vertical, pin pitch=5.08mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Vertical pin pitch 5.08mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P12.70mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=12.7mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 12.7mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P15.24mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=15.24mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 15.24mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P20.32mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=20.32mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 20.32mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0309_L9.0mm_D3.2mm_P25.40mm_Horizontal +Resistor, Axial_DIN0309 series, Axial, Horizontal, pin pitch=25.4mm, 0.5W = 1/2W, length*diameter=9*3.2mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0309 series Axial Horizontal pin pitch 25.4mm 0.5W = 1/2W length 9mm diameter 3.2mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P5.08mm_Vertical +Resistor, Axial_DIN0411 series, Axial, Vertical, pin pitch=5.08mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Vertical pin pitch 5.08mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P7.62mm_Vertical +Resistor, Axial_DIN0411 series, Axial, Vertical, pin pitch=7.62mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Vertical pin pitch 7.62mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P12.70mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=12.7mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 12.7mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P15.24mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=15.24mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 15.24mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P20.32mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=20.32mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 20.32mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0411_L9.9mm_D3.6mm_P25.40mm_Horizontal +Resistor, Axial_DIN0411 series, Axial, Horizontal, pin pitch=25.4mm, 1W, length*diameter=9.9*3.6mm^2 +Resistor Axial_DIN0411 series Axial Horizontal pin pitch 25.4mm 1W length 9.9mm diameter 3.6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P5.08mm_Vertical +Resistor, Axial_DIN0414 series, Axial, Vertical, pin pitch=5.08mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Vertical pin pitch 5.08mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P7.62mm_Vertical +Resistor, Axial_DIN0414 series, Axial, Vertical, pin pitch=7.62mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Vertical pin pitch 7.62mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P15.24mm_Horizontal +Resistor, Axial_DIN0414 series, Axial, Horizontal, pin pitch=15.24mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Horizontal pin pitch 15.24mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P20.32mm_Horizontal +Resistor, Axial_DIN0414 series, Axial, Horizontal, pin pitch=20.32mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Horizontal pin pitch 20.32mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0414_L11.9mm_D4.5mm_P25.40mm_Horizontal +Resistor, Axial_DIN0414 series, Axial, Horizontal, pin pitch=25.4mm, 2W, length*diameter=11.9*4.5mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0414 series Axial Horizontal pin pitch 25.4mm 2W length 11.9mm diameter 4.5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P5.08mm_Vertical +Resistor, Axial_DIN0516 series, Axial, Vertical, pin pitch=5.08mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Vertical pin pitch 5.08mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0516 series, Axial, Vertical, pin pitch=7.62mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Vertical pin pitch 7.62mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P20.32mm_Horizontal +Resistor, Axial_DIN0516 series, Axial, Horizontal, pin pitch=20.32mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Horizontal pin pitch 20.32mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0516 series, Axial, Horizontal, pin pitch=25.4mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Horizontal pin pitch 25.4mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0516_L15.5mm_D5.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0516 series, Axial, Horizontal, pin pitch=30.48mm, 2W, length*diameter=15.5*5mm^2, http://cdn-reichelt.de/documents/datenblatt/B400/1_4W%23YAG.pdf +Resistor Axial_DIN0516 series Axial Horizontal pin pitch 30.48mm 2W length 15.5mm diameter 5mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P5.08mm_Vertical +Resistor, Axial_DIN0614 series, Axial, Vertical, pin pitch=5.08mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Vertical pin pitch 5.08mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P7.62mm_Vertical +Resistor, Axial_DIN0614 series, Axial, Vertical, pin pitch=7.62mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Vertical pin pitch 7.62mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P15.24mm_Horizontal +Resistor, Axial_DIN0614 series, Axial, Horizontal, pin pitch=15.24mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Horizontal pin pitch 15.24mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P20.32mm_Horizontal +Resistor, Axial_DIN0614 series, Axial, Horizontal, pin pitch=20.32mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Horizontal pin pitch 20.32mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0614_L14.3mm_D5.7mm_P25.40mm_Horizontal +Resistor, Axial_DIN0614 series, Axial, Horizontal, pin pitch=25.4mm, 1.5W, length*diameter=14.3*5.7mm^2 +Resistor Axial_DIN0614 series Axial Horizontal pin pitch 25.4mm 1.5W length 14.3mm diameter 5.7mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P5.08mm_Vertical +Resistor, Axial_DIN0617 series, Axial, Vertical, pin pitch=5.08mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Vertical pin pitch 5.08mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0617 series, Axial, Vertical, pin pitch=7.62mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Vertical pin pitch 7.62mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P20.32mm_Horizontal +Resistor, Axial_DIN0617 series, Axial, Horizontal, pin pitch=20.32mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Horizontal pin pitch 20.32mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0617 series, Axial, Horizontal, pin pitch=25.4mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Horizontal pin pitch 25.4mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0617_L17.0mm_D6.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0617 series, Axial, Horizontal, pin pitch=30.48mm, 2W, length*diameter=17*6mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0617 series Axial Horizontal pin pitch 30.48mm 2W length 17mm diameter 6mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0918 series, Axial, Vertical, pin pitch=7.62mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Vertical pin pitch 7.62mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P22.86mm_Horizontal +Resistor, Axial_DIN0918 series, Axial, Horizontal, pin pitch=22.86mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Horizontal pin pitch 22.86mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0918 series, Axial, Horizontal, pin pitch=25.4mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Horizontal pin pitch 25.4mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0918_L18.0mm_D9.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0918 series, Axial, Horizontal, pin pitch=30.48mm, 4W, length*diameter=18*9mm^2 +Resistor Axial_DIN0918 series Axial Horizontal pin pitch 30.48mm 4W length 18mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0922_L20.0mm_D9.0mm_P7.62mm_Vertical +Resistor, Axial_DIN0922 series, Axial, Vertical, pin pitch=7.62mm, 5W, length*diameter=20*9mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0922 series Axial Vertical pin pitch 7.62mm 5W length 20mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0922_L20.0mm_D9.0mm_P25.40mm_Horizontal +Resistor, Axial_DIN0922 series, Axial, Horizontal, pin pitch=25.4mm, 5W, length*diameter=20*9mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0922 series Axial Horizontal pin pitch 25.4mm 5W length 20mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_DIN0922_L20.0mm_D9.0mm_P30.48mm_Horizontal +Resistor, Axial_DIN0922 series, Axial, Horizontal, pin pitch=30.48mm, 5W, length*diameter=20*9mm^2, http://www.vishay.com/docs/20128/wkxwrx.pdf +Resistor Axial_DIN0922 series Axial Horizontal pin pitch 30.48mm 5W length 20mm diameter 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P5.08mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=5.08mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 5.08mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P7.62mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=7.62mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 7.62mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P22.40mm +Resistor, Axial_Power series, Box, pin pitch=22.4mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 22.4mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P25.40mm +Resistor, Axial_Power series, Box, pin pitch=25.4mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 25.4mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L20.0mm_W6.4mm_P30.48mm +Resistor, Axial_Power series, Box, pin pitch=30.48mm, 4W, length*width*height=20*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 30.48mm 4W length 20mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W6.4mm_P27.94mm +Resistor, Axial_Power series, Box, pin pitch=27.94mm, 5W, length*width*height=25*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 27.94mm 5W length 25mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W6.4mm_P30.48mm +Resistor, Axial_Power series, Box, pin pitch=30.48mm, 5W, length*width*height=25*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 30.48mm 5W length 25mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P7.62mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=7.62mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 7.62mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P10.16mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=10.16mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 10.16mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P27.94mm +Resistor, Axial_Power series, Box, pin pitch=27.94mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 27.94mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L25.0mm_W9.0mm_P30.48mm +Resistor, Axial_Power series, Box, pin pitch=30.48mm, 7W, length*width*height=25*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 30.48mm 7W length 25mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W6.4mm_P40.64mm +Resistor, Axial_Power series, Box, pin pitch=40.64mm, 7W, length*width*height=38*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 40.64mm 7W length 38mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W6.4mm_P45.72mm +Resistor, Axial_Power series, Box, pin pitch=45.72mm, 7W, length*width*height=38*6.4*6.4mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 45.72mm 7W length 38mm width 6.4mm height 6.4mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W9.0mm_P40.64mm +Resistor, Axial_Power series, Box, pin pitch=40.64mm, 9W, length*width*height=38*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 40.64mm 9W length 38mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L38.0mm_W9.0mm_P45.72mm +Resistor, Axial_Power series, Box, pin pitch=45.72mm, 9W, length*width*height=38*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 45.72mm 9W length 38mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P7.62mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=7.62mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 7.62mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P10.16mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=10.16mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 10.16mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P55.88mm +Resistor, Axial_Power series, Box, pin pitch=55.88mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 55.88mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L48.0mm_W12.5mm_P60.96mm +Resistor, Axial_Power series, Box, pin pitch=60.96mm, 15W, length*width*height=48*12.5*12.5mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 60.96mm 15W length 48mm width 12.5mm height 12.5mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L50.0mm_W9.0mm_P55.88mm +Resistor, Axial_Power series, Box, pin pitch=55.88mm, 11W, length*width*height=50*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 55.88mm 11W length 50mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L50.0mm_W9.0mm_P60.96mm +Resistor, Axial_Power series, Box, pin pitch=60.96mm, 11W, length*width*height=50*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 60.96mm 11W length 50mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L60.0mm_W14.0mm_P10.16mm_Vertical +Resistor, Axial_Power series, Axial, Vertical, pin pitch=10.16mm, 25W, length*width*height=60*14*14mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Axial Vertical pin pitch 10.16mm 25W length 60mm width 14mm height 14mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L60.0mm_W14.0mm_P66.04mm +Resistor, Axial_Power series, Box, pin pitch=66.04mm, 25W, length*width*height=60*14*14mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 66.04mm 25W length 60mm width 14mm height 14mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L60.0mm_W14.0mm_P71.12mm +Resistor, Axial_Power series, Box, pin pitch=71.12mm, 25W, length*width*height=60*14*14mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 71.12mm 25W length 60mm width 14mm height 14mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L75.0mm_W9.0mm_P81.28mm +Resistor, Axial_Power series, Box, pin pitch=81.28mm, 17W, length*width*height=75*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 81.28mm 17W length 75mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Power_L75.0mm_W9.0mm_P86.36mm +Resistor, Axial_Power series, Box, pin pitch=86.36mm, 17W, length*width*height=75*9*9mm^3, http://cdn-reichelt.de/documents/datenblatt/B400/5WAXIAL_9WAXIAL_11WAXIAL_17WAXIAL%23YAG.pdf +Resistor Axial_Power series Box pin pitch 86.36mm 17W length 75mm width 9mm height 9mm +0 +2 +2 +Resistor_THT +R_Axial_Shunt_L22.2mm_W8.0mm_PS14.30mm_P25.40mm +Resistor, Axial_Shunt series, Box, pin pitch=25.4mm, 3W, length*width*height=22.2*8*8mm^3, shunt pin pitch = 14.30mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 25.4mm 3W length 22.2mm width 8mm height 8mm shunt pin pitch 14.30mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L22.2mm_W9.5mm_PS14.30mm_P25.40mm +Resistor, Axial_Shunt series, Box, pin pitch=25.4mm, 5W, length*width*height=22.2*9.5*9.5mm^3, shunt pin pitch = 14.30mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 25.4mm 5W length 22.2mm width 9.5mm height 9.5mm shunt pin pitch 14.30mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L35.3mm_W9.5mm_PS25.40mm_P38.10mm +Resistor, Axial_Shunt series, Box, pin pitch=38.1mm, 7W, length*width*height=35.3*9.5*9.5mm^3, shunt pin pitch = 25.40mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 38.1mm 7W length 35.3mm width 9.5mm height 9.5mm shunt pin pitch 25.40mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L47.6mm_W9.5mm_PS34.93mm_P50.80mm +Resistor, Axial_Shunt series, Box, pin pitch=50.8mm, 10W, length*width*height=47.6*9.5*9.5mm^3, shunt pin pitch = 34.93mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 50.8mm 10W length 47.6mm width 9.5mm height 9.5mm shunt pin pitch 34.93mm +0 +4 +4 +Resistor_THT +R_Axial_Shunt_L47.6mm_W12.7mm_PS34.93mm_P50.80mm +Resistor, Axial_Shunt series, Box, pin pitch=50.8mm, 15W, length*width*height=47.6*12.7*12.7mm^3, shunt pin pitch = 34.93mm, http://www.vishay.com/docs/30217/cpsl.pdf +Resistor Axial_Shunt series Box pin pitch 50.8mm 15W length 47.6mm width 12.7mm height 12.7mm shunt pin pitch 34.93mm +0 +4 +4 +Resistor_THT +R_Bare_Metal_Element_L12.4mm_W4.8mm_P11.40mm +Resistor, Bare_Metal_Element series, Bare Metal Strip/Wire, Horizontal, pin pitch=11.4mm, 1W, length*width=12.4*4.8mm^2, https://www.bourns.com/pdfs/PWR4412-2S.pdf +Resistor Bare_Metal_Element series Bare Metal Strip Wire Horizontal pin pitch 11.4mm 1W length 12.4mm width 4.8mm +0 +2 +2 +Resistor_THT +R_Bare_Metal_Element_L16.3mm_W4.8mm_P15.30mm +Resistor, Bare_Metal_Element series, Bare Metal Strip/Wire, Horizontal, pin pitch=15.3mm, 3W, length*width=16.3*4.8mm^2, https://www.bourns.com/pdfs/PWR4412-2S.pdf +Resistor Bare_Metal_Element series Bare Metal Strip Wire Horizontal pin pitch 15.3mm 3W length 16.3mm width 4.8mm +0 +2 +2 +Resistor_THT +R_Bare_Metal_Element_L21.3mm_W4.8mm_P20.30mm +Resistor, Bare_Metal_Element series, Bare Metal Strip/Wire, Horizontal, pin pitch=20.3mm, 5W, length*width=21.3*4.8mm^2, https://www.bourns.com/pdfs/PWR4412-2S.pdf +Resistor Bare_Metal_Element series Bare Metal Strip Wire Horizontal pin pitch 20.3mm 5W length 21.3mm width 4.8mm +0 +2 +2 +Resistor_THT +R_Box_L8.4mm_W2.5mm_P5.08mm +Resistor, Box series, Radial, pin pitch=5.08mm, 0.5W = 1/2W, length*width=8.38*2.54mm^2, http://www.vishay.com/docs/60051/cns020.pdf +Resistor Box series Radial pin pitch 5.08mm 0.5W = 1/2W length 8.38mm width 2.54mm +0 +2 +2 +Resistor_THT +R_Box_L13.0mm_W4.0mm_P9.00mm +Resistor, Box series, Radial, pin pitch=9.00mm, 2W, length*width=13.0*4.0mm^2, http://www.produktinfo.conrad.com/datenblaetter/425000-449999/443860-da-01-de-METALLBAND_WIDERSTAND_0_1_OHM_5W_5Pr.pdf +Resistor Box series Radial pin pitch 9.00mm 2W length 13.0mm width 4.0mm +0 +2 +2 +Resistor_THT +R_Box_L14.0mm_W5.0mm_P9.00mm +Resistor, Box series, Radial, pin pitch=9.00mm, 5W, length*width=14.0*5.0mm^2, http://www.produktinfo.conrad.com/datenblaetter/425000-449999/443860-da-01-de-METALLBAND_WIDERSTAND_0_1_OHM_5W_5Pr.pdf +Resistor Box series Radial pin pitch 9.00mm 5W length 14.0mm width 5.0mm +0 +2 +2 +Resistor_THT +R_Box_L26.0mm_W5.0mm_P20.00mm +Resistor, Box series, Radial, pin pitch=20.00mm, 10W, length*width=26.0*5.0mm^2, http://www.produktinfo.conrad.com/datenblaetter/425000-449999/443860-da-01-de-METALLBAND_WIDERSTAND_0_1_OHM_5W_5Pr.pdf +Resistor Box series Radial pin pitch 20.00mm 10W length 26.0mm width 5.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L7.0mm_W8.0mm_Px2.40mm_Py2.30mm +Resistor, Radial_Power series, Radial, pin pitch=2.40*2.30mm^2, 7W, length*width=7*8mm^2, http://www.vitrohm.com/content/files/vitrohm_series_kv_-_201601.pdf +Resistor Radial_Power series Radial pin pitch 2.40*2.30mm^2 7W length 7mm width 8mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L9.0mm_W10.0mm_Px2.70mm_Py2.30mm +Resistor, Radial_Power series, Radial, pin pitch=2.70*2.30mm^2, 17W, length*width=9*10mm^2, http://www.vitrohm.com/content/files/vitrohm_series_kv_-_201601.pdf +Resistor Radial_Power series Radial pin pitch 2.70*2.30mm^2 17W length 9mm width 10mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L11.0mm_W7.0mm_P5.00mm +Resistor, Radial_Power series, Radial, pin pitch=5.00mm, 2W, length*width=11.0*7.0mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 5.00mm 2W length 11.0mm width 7.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L12.0mm_W8.0mm_P5.00mm +Resistor, Radial_Power series, Radial, pin pitch=5.00mm, 3W, length*width=12.0*8.0mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 5.00mm 3W length 12.0mm width 8.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L13.0mm_W9.0mm_P5.00mm +Resistor, Radial_Power series, Radial, pin pitch=5.00mm, 7W, length*width=13.0*9.0mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 5.00mm 7W length 13.0mm width 9.0mm +0 +2 +2 +Resistor_THT +R_Radial_Power_L16.1mm_W9.0mm_P7.37mm +Resistor, Radial_Power series, Radial, pin pitch=7.37mm, 10W, length*width=16.1*9mm^2, http://www.vishay.com/docs/30218/cpcx.pdf +Resistor Radial_Power series Radial pin pitch 7.37mm 10W length 16.1mm width 9mm +0 +2 +2 +Rotary_Encoder +RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm +Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E... with switch, vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC11E_Vertical_H20mm +Alps rotary encoder, EC12E... without switch (pins are dummy), vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +4 +Rotary_Encoder +RotaryEncoder_Alps_EC11E_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E... without switch (pins are dummy), vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +4 +Rotary_Encoder +RotaryEncoder_Alps_EC12E-Switch_Vertical_H20mm +Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html & http://cdn-reichelt.de/documents/datenblatt/F100/402097STEC12E08.PDF +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC12E-Switch_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E... with switch, vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html & http://cdn-reichelt.de/documents/datenblatt/F100/402097STEC12E08.PDF +rotary encoder +0 +7 +6 +Rotary_Encoder +RotaryEncoder_Alps_EC12E_Vertical_H20mm +Alps rotary encoder, EC12E..., vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html +rotary encoder +0 +5 +4 +Rotary_Encoder +RotaryEncoder_Alps_EC12E_Vertical_H20mm_CircularMountingHoles +Alps rotary encoder, EC12E..., vertical shaft, mounting holes with circular drills, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC12E/EC12E1240405.html +rotary encoder +0 +5 +4 +Sensor +Aosong_DHT11_5.5x12.0_P2.54mm +Temperature and humidity module, http://akizukidenshi.com/download/ds/aosong/DHT11.pdf +Temperature and humidity module +0 +4 +4 +Sensor +MQ-6 +Gas Sensor, 6 pin, https://www.winsen-sensor.com/d/files/semiconductor/mq-6.pdf +gas sensor +0 +6 +6 +Sensor +SHT1x +SHT1x +SHT1x +0 +8 +8 +Sensor_Audio +CUI_CMC-4013-SMT +Omnidirectional, -42dB, reflowable, electret condenser microphone https://www.cuidevices.com/product/resource/cmc-4013-smt-tr.pdf +Microphone CUI +0 +2 +2 +Sensor_Audio +Infineon_PG-LLGA-5-1 +Infineon_PG-LLGA-5-1 StepUp generated footprint, https://www.infineon.com/cms/en/product/packages/PG-LLGA/PG-LLGA-5-1/ +infineon mems microphone +0 +15 +5 +Sensor_Audio +ST_HLGA-6_3.76x4.72mm_P1.65mm +http://www.st.com/content/ccc/resource/technical/document/datasheet/group3/27/62/48/98/44/54/4d/36/DM00303211/files/DM00303211.pdf/jcr:content/translations/en.DM00303211.pdf +HLGA Sensor Audio +0 +6 +6 +Sensor_Current +AKM_CQ_7 +AKM Current Sensor, 7 pin, THT (http://www.akm.com/akm/en/file/datasheet/CQ-236B.pdf) +akm current sensor tht +0 +39 +7 +Sensor_Current +AKM_CQ_7S +AKM Current Sensor, 7 pin, SMD (http://www.akm.com/akm/en/file/datasheet/CQ-236B.pdf) +akm current sensor smd +0 +19 +7 +Sensor_Current +AKM_CQ_VSOP-24_5.6x7.9mm_P0.65mm +AKM VSOP-24 current sensor, 5.6x7.9mm body, 0.65mm pitch (http://www.akm.com/akm/en/file/datasheet/CQ-330J.pdf) +akm vsop 24 +0 +10 +10 +Sensor_Current +AKM_CZ_SSOP-10_6.5x8.1mm_P0.95mm +AKM CZ-381x current sensor, 6.5x8.1mm body, 0.95mm pitch (http://www.akm.com/akm/en/product/detail/0009/) +akm cz-381x 10 +0 +10 +10 +Sensor_Current +Allegro_CB_PFF +Allegro MicroSystems, CB-PFF Package (http://www.allegromicro.com/en/Products/Current-Sensor-ICs/Fifty-To-Two-Hundred-Amp-Integrated-Conductor-Sensor-ICs/ACS758.aspx) !PADS 4-5 DO NOT MATCH DATASHEET! +Allegro CB-PFF +0 +37 +5 +Sensor_Current +Allegro_CB_PSF +Allegro MicroSystems, CB-PSF Package (http://www.allegromicro.com/en/Products/Current-Sensor-ICs/Fifty-To-Two-Hundred-Amp-Integrated-Conductor-Sensor-ICs/ACS758.aspx) +Allegro CB-PSF +0 +5 +5 +Sensor_Current +Allegro_CB_PSS +Allegro MicroSystems, CB-PSS Package (http://www.allegromicro.com/en/Products/Current-Sensor-ICs/Fifty-To-Two-Hundred-Amp-Integrated-Conductor-Sensor-ICs/ACS758.aspx) +Allegro CB-PSS +0 +5 +5 +Sensor_Current +Allegro_PSOF-7_4.8x6.4mm_P1.60mm +Allegro Microsystems PSOF-7, 4.8x6.4mm Body, 1.60mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/ACS780-Datasheet.ashx) +Allegro PSOF-7 +0 +7 +7 +Sensor_Current +Allegro_QFN-12-10-1EP_3x3mm_P0.5mm +Allegro Microsystems 12-Lead (10-Lead Populated) Quad Flat Pack, 3x3mm Body, 0.5mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/ACS711-Datasheet.ashx) +Allegro QFN 0.5 +0 +14 +10 +Sensor_Current +Allegro_QSOP-24_3.9x8.7mm_P0.635mm +Allegro Microsystems 24-Lead Plastic Shrink Small Outline Narrow Body Body [QSOP] (http://www.allegromicro.com/~/media/Files/Datasheets/ACS726-Datasheet.ashx?la=en) +Allegro QSOP 0.635 +0 +24 +24 +Sensor_Current +Allegro_SIP-3 +Allegro Microsystems SIP-3, 1.27mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/A1369-Datasheet.ashx) +Allegro SIP-3 +0 +3 +3 +Sensor_Current +Allegro_SIP-4 +Allegro Microsystems SIP-4, 1.27mm Pitch (http://www.allegromicro.com/~/media/Files/Datasheets/A1363-Datasheet.ashx) +Allegro SIP-4 +0 +4 +4 +Sensor_Current +Diodes_SIP-3_4.1x1.5mm_P1.27mm +Diodes SIP-3 Bulk Pack, 1.27mm Pitch (https://www.diodes.com/assets/Package-Files/SIP-3-Bulk-Pack.pdf) +Diodes SIP-3 Bulk Pack +0 +3 +3 +Sensor_Current +Diodes_SIP-3_4.1x1.5mm_P2.65mm +Diodes SIP-3 Ammo Pack, 2.65mm Pitch (https://www.diodes.com/assets/Package-Files/SIP-3-Ammo-Pack.pdf) +Diodes SIP-3 Ammo Pack +0 +3 +3 +Sensor_Current +Honeywell_CSLW +https://sensing.honeywell.com/honeywell-sensing-cslw-series-product-sheet-005861-1-en.pdf +Miniature Wired Open-Loop Current Sensor +0 +5 +5 +Sensor_Current +LEM_CKSR +LEM CKSR 6/15/25/50/75-NP Current Transducer, https://www.lem.com/sites/default/files/products_datasheets/cksr_75-np.pdf +current transducer LEM +0 +14 +14 +Sensor_Current +LEM_HO8-NP +LEM HO 8/15/25-NP Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-np-0000_series.pdf) +current transducer +0 +13 +13 +Sensor_Current +LEM_HO8-NSM +LEM HO 8/15/25-NSM Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-nsm-0000_series.pdf) +current transducer +0 +13 +13 +Sensor_Current +LEM_HO40-NP +LEM HO 40/60/120/150-NP Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-np_0100__1100_series.pdf) +current transducer +0 +13 +13 +Sensor_Current +LEM_HTFS +LEM HTFS x00-P current transducer (https://www.lem.com/sites/default/files/products_datasheets/htfs_200_800-p.pdf) +HTFS current transducer +0 +4 +4 +Sensor_Current +LEM_HX02-P +LEM HX02-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX03-P-SP2 +LEM HX03-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX04-P +LEM HX04-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX05-NP +LEM HX05-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf) +hall current +0 +8 +8 +Sensor_Current +LEM_HX05-P-SP2 +LEM HX05-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX06-P +LEM HX06-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX10-NP +LEM HX10-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf) +hall current +0 +8 +8 +Sensor_Current +LEM_HX10-P-SP2 +LEM HX10-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX15-NP +LEM HX15-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf) +hall current +0 +8 +8 +Sensor_Current +LEM_HX15-P-SP2 +LEM HX15-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX20-P-SP2 +LEM HX20-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX25-P-SP2 +LEM HX25-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_HX50-P-SP2 +LEM HX50-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf) +hall current +0 +6 +6 +Sensor_Current +LEM_LA25-P +LEM Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/la_25-p.pdf) +current transducer +0 +3 +3 +Sensor_Current +LEM_LTSR-NP +LEM current transducer LEM_LTSR-NP 5V supply voltage series https://www.lem.com/sites/default/files/products_datasheets/ltsr_6-np.pdf +Current transducer +0 +10 +10 +Sensor_Distance +ST_VL53L1x +VL53L1x distance sensor +VL53L1CXV0FY1 VL53L1x +0 +13 +12 +Sensor_Humidity +Sensirion_DFN-4-1EP_2x2mm_P1mm_EP0.7x1.6mm +DFN, 4 Pin (https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/0_Datasheets/Humidity/Sensirion_Humidity_Sensors_SHTC3_Datasheet.pdf) +Sensirion DFN NoLead +0 +10 +5 +Sensor_Humidity +Sensirion_DFN-8-1EP_2.5x2.5mm_P0.5mm_EP1.1x1.7mm +Sensirion DFN-8 SHT3x-DIS (https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/2_Humidity_Sensors/Datasheets/Sensirion_Humidity_Sensors_SHT3x_Datasheet_digital.pdf) +sensirion dfn nolead +0 +10 +9 +Sensor_Motion +InvenSense_QFN-24_3x3mm_P0.4mm +24-Lead Plastic QFN (3mm x 3mm); Pitch 0.4mm; EP 1.7x1.54mm; for InvenSense motion sensors; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU9250REV1.0.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.4 +0 +24 +24 +Sensor_Motion +InvenSense_QFN-24_3x3mm_P0.4mm_NoMask +24-Lead Plastic QFN (3mm x 3mm); Pitch 0.4mm; EP 1.7x1.54mm; for InvenSense motion sensors; Mask removed below exposed pad; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU9250REV1.0.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.4 +0 +25 +24 +Sensor_Motion +InvenSense_QFN-24_4x4mm_P0.5mm +24-Lead Plastic QFN (4mm x 4mm); Pitch 0.5mm; EP 2.7x2.6mm; for InvenSense motion sensors; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.5 +0 +24 +24 +Sensor_Motion +InvenSense_QFN-24_4x4mm_P0.5mm_NoMask +24-Lead Plastic QFN (4mm x 4mm); Pitch 0.5mm; EP 2.7x2.6mm; for InvenSense motion sensors; Mask removed below exposed pad; keepout area marked (Package see: https://store.invensense.com/datasheets/invensense/MPU-6050_DataSheet_V3%204.pdf; See also https://www.invensense.com/wp-content/uploads/2015/02/InvenSense-MEMS-Handling.pdf) +QFN 0.5 +0 +25 +24 +Sensor_Pressure +Freescale_98ARH99066A +https://www.nxp.com/docs/en/data-sheet/MPXH6250A.pdf +sensor pressure ssop 98ARH99066A +0 +8 +8 +Sensor_Pressure +Freescale_98ARH99089A +https://www.nxp.com/docs/en/data-sheet/MPXH6250A.pdf +sensor pressure ssop 98ARH99089A +0 +8 +8 +Sensor_Pressure +Honeywell_40PCxxxG1A +https://www.honeywellscportal.com/index.php?ci_id=138832 +pressure sensor automotive honeywell +0 +3 +3 +Sensor_Voltage +LEM_LV25-P +LEM LV25-P Voltage transducer, https://www.lem.com/sites/default/files/products_datasheets/lv_25-p.pdf +LEM Hall Effect Voltage transducer +0 +5 +5 +Socket +3M_Textool_240-1288-00-0602J_2x20_P2.54mm +3M 40-pin zero insertion force socket, though-hole, row spacing 25.4 mm (1000 mils) +THT DIP DIL ZIF 25.4mm 1000mil Socket +0 +40 +40 +Socket +DIP_Socket-14_W4.3_W5.08_W7.62_W10.16_W10.9_3M_214-3339-00-0602J +3M 14-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +14 +14 +Socket +DIP_Socket-16_W4.3_W5.08_W7.62_W10.16_W10.9_3M_216-3340-00-0602J +3M 16-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +16 +16 +Socket +DIP_Socket-18_W4.3_W5.08_W7.62_W10.16_W10.9_3M_218-3341-00-0602J +3M 18-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +18 +18 +Socket +DIP_Socket-20_W4.3_W5.08_W7.62_W10.16_W10.9_3M_220-3342-00-0602J +3M 20-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +20 +20 +Socket +DIP_Socket-22_W6.9_W7.62_W10.16_W12.7_W13.5_3M_222-3343-00-0602J +3M 22-pin zero insertion force socket, through-hole, row spacing 10.16 mm (400 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 10.16mm 400mil Socket +0 +22 +22 +Socket +DIP_Socket-24_W4.3_W5.08_W7.62_W10.16_W10.9_3M_224-5248-00-0602J +3M 24-pin zero insertion force socket, through-hole, row spacing 7.62 mm (300 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 7.62mm 300mil Socket +0 +24 +24 +Socket +DIP_Socket-24_W11.9_W12.7_W15.24_W17.78_W18.5_3M_224-1275-00-0602J +3M 24-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +24 +24 +Socket +DIP_Socket-28_W6.9_W7.62_W10.16_W12.7_W13.5_3M_228-4817-00-0602J +3M 28-pin zero insertion force socket, through-hole, row spacing 10.16 mm (400 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 10.16mm 400mil Socket +0 +28 +28 +Socket +DIP_Socket-28_W11.9_W12.7_W15.24_W17.78_W18.5_3M_228-1277-00-0602J +3M 28-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +28 +28 +Socket +DIP_Socket-32_W11.9_W12.7_W15.24_W17.78_W18.5_3M_232-1285-00-0602J +3M 32-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +32 +32 +Socket +DIP_Socket-40_W11.9_W12.7_W15.24_W17.78_W18.5_3M_240-1280-00-0602J +3M 40-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +40 +40 +Socket +DIP_Socket-40_W22.1_W22.86_W25.4_W27.94_W28.7_3M_240-3639-00-0602J +3M 40-pin zero insertion force socket, through-hole, row spacing 25.4 mm (1000 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 25.4mm 1000mil Socket +0 +40 +40 +Socket +DIP_Socket-42_W11.9_W12.7_W15.24_W17.78_W18.5_3M_242-1281-00-0602J +3M 42-pin zero insertion force socket, through-hole, row spacing 15.24 mm (600 mils), http://multimedia.3m.com/mws/media/494546O/3mtm-dip-sockets-100-2-54-mm-ts0365.pdf +THT DIP DIL ZIF 15.24mm 600mil Socket +0 +42 +42 +Socket +Wells_648-0482211SA01 +https://www.farnell.com/cad/316865.pdf?_ga=2.37208032.177107060.1530611323-249019997.1498114824 +48pin TSOP Socket +0 +48 +48 +SofleRGB +1pin_conn +Resitance 3 pas +R +0 +1 +1 +SofleRGB +3x1header + + +0 +3 +3 +SofleRGB +HOLE_M2_TH + + +0 +1 +0 +SofleRGB +Jumper + + +0 +2 +2 +SofleRGB +LED + + +0 +3 +3 +SofleRGB +M2_HOLE_PCB + + +0 +1 +0 +SofleRGB +MJ-4PP-9 + + +0 +8 +4 +SofleRGB +OLED_4Pin +Connecteur 6 pins +CONN DEV +0 +4 +4 +SofleRGB +ProMicro + + +0 +48 +24 +SofleRGB +RESISTOR_mini +Resitance 3 pas +R +0 +2 +2 +SofleRGB +RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified +Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html +rotary encoder +0 +7 +6 +SofleRGB +SK6812MINI_and_cherry + + +0 +12 +6 +SofleRGB +SK6812MINI_underglow_dev + + +0 +8 +4 +SofleRGB +TACT_SWITCH_TVBP06 + + +0 +2 +2 +SofleRGB +crkbd-diode +Resitance 3 pas +R +0 +4 +2 +SofleRGB +gecko-logo + + +0 +0 +0 +SofleRGB +jumper_data + + +0 +2 +2 +Symbol +CE-Logo_8.5x6mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_11.2x8mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_16.8x12mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_28x20mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_42x30mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +CE-Logo_56.1x40mm_SilkScreen +CE marking +Logo CE certification +0 +0 +0 +Symbol +ESD-Logo_6.6x6mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_8.9x8mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_13.2x12mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_22x20mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_33x30mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +ESD-Logo_44.1x40mm_SilkScreen +Electrostatic discharge Logo +Logo ESD +0 +0 +0 +Symbol +FCC-Logo_7.3x6mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_9.6x8mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_14.6x12mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_24.2x20mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_36.3x30mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +FCC-Logo_48.3x40mm_SilkScreen +FCC marking +Logo FCC certification +0 +0 +0 +Symbol +KiCad-Logo2_5mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_5mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_6mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_6mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_8mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_8mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_12mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_12mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_20mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_20mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_30mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_30mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_40mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo2_40mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_5mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_5mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_6mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_6mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_8mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_8mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_12mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_12mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_20mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_20mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_30mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_30mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_40mm_Copper +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +KiCad-Logo_40mm_SilkScreen +KiCad Logo +Logo KiCad +0 +0 +0 +Symbol +OSHW-Logo2_7.3x6mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_7.3x6mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_9.8x8mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_9.8x8mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_14.6x12mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_14.6x12mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_24.3x20mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_24.3x20mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_36.5x30mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_36.5x30mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_48.7x40mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo2_48.7x40mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Logo_5.7x6mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_5.7x6mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_7.5x8mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_7.5x8mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_11.4x12mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_11.4x12mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_19x20mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_19x20mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_28.5x30mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_28.5x30mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_38.1x40mm_Copper +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Logo_38.1x40mm_SilkScreen +Open Source Hardware Logo +Logo OSHW +0 +0 +0 +Symbol +OSHW-Symbol_6.7x6mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_6.7x6mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_8.9x8mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_8.9x8mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_13.4x12mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_13.4x12mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_22.3x20mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_22.3x20mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_33.5x30mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_33.5x30mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_44.5x40mm_Copper +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +OSHW-Symbol_44.5x40mm_SilkScreen +Open Source Hardware Symbol +Logo Symbol OSHW +0 +0 +0 +Symbol +Polarity_Center_Negative_6mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_8mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_12mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_20mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_30mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Negative_40mm_SilkScreen +Polarity Logo, Center Negative +Logo Polarity Center Negative +0 +0 +0 +Symbol +Polarity_Center_Positive_6mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_8mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_12mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_20mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_30mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +Polarity_Center_Positive_40mm_SilkScreen +Polarity Logo, Center Positive +Logo Polarity Center Positive +0 +0 +0 +Symbol +RoHS-Logo_6mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_8mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_12mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_20mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_30mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +RoHS-Logo_40mm_SilkScreen +Restriction of Hazardous Substances Directive Logo +Logo RoHS +0 +0 +0 +Symbol +Symbol_Attention_CopperTop_Big +Symbol, Attention, Copper Top, Big, +Symbol, Attention, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_Attention_CopperTop_Small +Symbol, Attention, Copper Top, Small, +Symbol, Attention, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_Barrel_Polarity +Barrel connector polarity indicator +barrel polarity +0 +0 +0 +Symbol +Symbol_CC-Attribution_CopperTop_Big +Symbol, CC-Attribution, Copper Top, Big, +Symbol, CC-Attribution, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-Attribution_CopperTop_Small +Symbol, CC-Share Alike, Copper Top, Small, +Symbol, CC-Share Alike, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CC-Noncommercial_CopperTop_Big +Symbol, CC-Noncommercial, Copper Top, Big, +Symbol, CC-Noncommercial, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-Noncommercial_CopperTop_Small +Symbol, CC-Noncommercial Alike, Copper Top, Small, +Symbol, CC-Noncommercial Alike, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CC-PublicDomain_CopperTop_Big +Symbol, CC-PublicDomain, Copper Top, Big, +Symbol, CC-PublicDomain, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-PublicDomain_CopperTop_Small +Symbol, CC-Public Domain, Copper Top, Small, +Symbol, CC-Public Domain, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CC-PublicDomain_SilkScreenTop_Big +Symbol, CC-PublicDomain, SilkScreen Top, Big, +Symbol, CC-PublicDomain, SilkScreen Top, Big, +0 +0 +0 +Symbol +Symbol_CC-ShareAlike_CopperTop_Big +Symbol, CC-Share Alike, Copper Top, Big, +Symbol, CC-Share Alike, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_CC-ShareAlike_CopperTop_Small +Symbol, CC-Share Alike, Copper Top, Small, +Symbol, CC-Share Alike, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommonsPublicDomain_CopperTop_Small +Symbol, Creative Commons Public Domain, CopperTop, Small, +Symbol, Creative Commons Public Domain, CopperTop, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommonsPublicDomain_SilkScreenTop_Small +Symbol, Creative Commons Public Domain, SilkScreenTop, Small, +Symbol, Creative Commons Public Domain, SilkScreen Top, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommons_CopperTop_Type1_Big +Symbol, Creative Commons, CopperTop, Type 1, Big, +Symbol, Creative Commons, CopperTop, Type 1, Big, +0 +0 +0 +Symbol +Symbol_CreativeCommons_CopperTop_Type2_Big +Symbol, Creative Commons, CopperTop, Type 2, Big, +Symbol, Creative Commons, CopperTop, Type 2, Big, +0 +0 +0 +Symbol +Symbol_CreativeCommons_CopperTop_Type2_Small +Symbol, Creative Commons, CopperTop, Type 2, Small, +Symbol, Creative Commons, CopperTop, Type 2, Small, +0 +0 +0 +Symbol +Symbol_CreativeCommons_SilkScreenTop_Type2_Big +Symbol, Creative Commons, SilkScreen Top, Type 2, Big, +Symbol, Creative Commons, SilkScreen Top, Type 2, Big, +0 +0 +0 +Symbol +Symbol_Danger_CopperTop_Big +Symbol, Danger, CopperTop, Big, +Symbol, Danger, CopperTop, Big, +0 +0 +0 +Symbol +Symbol_Danger_CopperTop_Small +Symbol, Danger, Copper Top, Small, +Symbol, Danger, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_ESD-Logo-Text_CopperTop + + +0 +0 +0 +Symbol +Symbol_ESD-Logo_CopperTop +ESD-Logo, similar JEDEC-14, without text, ohne Text, Copper Top, +ESD-Logo, similar JEDEC-14, without text, ohne Text, Copper Top, +0 +0 +0 +Symbol +Symbol_GNU-GPL_CopperTop_Big +Symbol, GNU-GPL, Copper Top, Big, +Symbol, GNU-GPL, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_GNU-GPL_CopperTop_Small +Symbol, GNU-GPL, Copper Top, Small, +Symbol, GNU-GPL, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_GNU-Logo_CopperTop +GNU-Logo, GNU-Head, GNU-Kopf, Copper Top, +GNU-Logo, GNU-Head, GNU-Kopf, Copper Top, +0 +0 +0 +Symbol +Symbol_GNU-Logo_SilkscreenTop +GNU-Logo, GNU-Head, GNU-Kopf, Silkscreen, +GNU-Logo, GNU-Head, GNU-Kopf, Silkscreen, +0 +0 +0 +Symbol +Symbol_HighVoltage_Type1_CopperTop_Big +Symbol, HighVoltage, Type1, Copper Top, Big, +Symbol, HighVoltage, Type1, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_HighVoltage_Type2_CopperTop_Big +Symbol, HighVoltage, Type2, Copper Top, Big, +Symbol, HighVoltage, Type2, Copper Top, Big, +0 +0 +0 +Symbol +Symbol_HighVoltage_Type2_CopperTop_VerySmall +Symbol, High Voltage, Type 2, Copper Top, Very Small, +Symbol, High Voltage, Type 2, Copper Top, Very Small, +0 +0 +0 +Symbol +Symbol_Highvoltage_Type1_CopperTop_Small +Symbol, Highvoltage, Type 1, Copper Top, Small, +Symbol, Highvoltage, Type 1, Copper Top, Small, +0 +0 +0 +Symbol +Symbol_Highvoltage_Type2_CopperTop_Small +Symbol, Highvoltage, Type 2, Copper Top, Small, +Symbol, Highvoltage, Type 2, Copper Top, Small, +0 +0 +0 +Symbol +WEEE-Logo_4.2x6mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_5.6x8mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_8.4x12mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_14x20mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_21x30mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +Symbol +WEEE-Logo_28.1x40mm_SilkScreen +Waste Electrical and Electronic Equipment Directive +Logo WEEE +0 +0 +0 +TerminalBlock +TerminalBlock_Altech_AK300-2_P5.00mm +Altech AK300 terminal block, pitch 5.0mm, 45 degree angled, see http://www.mouser.com/ds/2/16/PCBMETRC-24178.pdf +Altech AK300 terminal block pitch 5.0mm +0 +2 +2 +TerminalBlock +TerminalBlock_Altech_AK300-3_P5.00mm +Altech AK300 terminal block, pitch 5.0mm, 45 degree angled, see http://www.mouser.com/ds/2/16/PCBMETRC-24178.pdf +Altech AK300 terminal block pitch 5.0mm +0 +3 +3 +TerminalBlock +TerminalBlock_Altech_AK300-4_P5.00mm +Altech AK300 terminal block, pitch 5.0mm, 45 degree angled, see http://www.mouser.com/ds/2/16/PCBMETRC-24178.pdf +Altech AK300 terminal block pitch 5.0mm +0 +4 +4 +TerminalBlock +TerminalBlock_Wuerth_691311400102_P7.62mm +https://katalog.we-online.de/em/datasheet/6913114001xx.pdf +Wuerth WR-TBL Series 3114 terminal block pitch 7.62mm +0 +2 +2 +TerminalBlock +TerminalBlock_bornier-2_P5.08mm +simple 2-pin terminal block, pitch 5.08mm, revamped version of bornier2 +terminal block bornier2 +0 +2 +2 +TerminalBlock +TerminalBlock_bornier-3_P5.08mm +simple 3-pin terminal block, pitch 5.08mm, revamped version of bornier3 +terminal block bornier3 +0 +3 +3 +TerminalBlock +TerminalBlock_bornier-4_P5.08mm +simple 4-pin terminal block, pitch 5.08mm, revamped version of bornier4 +terminal block bornier4 +0 +4 +4 +TerminalBlock +TerminalBlock_bornier-5_P5.08mm +simple 5-pin terminal block, pitch 5.08mm, revamped version of bornier5 +terminal block bornier5 +0 +5 +5 +TerminalBlock +TerminalBlock_bornier-6_P5.08mm +simple 6pin terminal block, pitch 5.08mm, revamped version of bornier6 +terminal block bornier6 +0 +6 +6 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x02_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 19963, 2 pins, pitch 3.5mm, size 7.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/19963.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 19963 pitch 3.5mm size 7.7x7mm^2 drill 1.2mm pad 2.4mm +0 +2 +2 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x02_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10693, vertical (cable from top), 2 pins, pitch 3.5mm, size 8x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10693.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10693 vertical pitch 3.5mm size 8x8.3mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x03_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 20193, 3 pins, pitch 3.5mm, size 11.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/20193.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 20193 pitch 3.5mm size 11.2x7mm^2 drill 1.2mm pad 2.4mm +0 +3 +3 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x03_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10694, vertical (cable from top), 3 pins, pitch 3.5mm, size 11.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10694.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10694 vertical pitch 3.5mm size 11.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x04_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 20001, 4 pins, pitch 3.5mm, size 14.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/20001.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 20001 pitch 3.5mm size 14.7x7mm^2 drill 1.2mm pad 2.4mm +0 +4 +4 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x04_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10695, vertical (cable from top), 4 pins, pitch 3.5mm, size 15x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10695.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10695 vertical pitch 3.5mm size 15x8.3mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x05_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 20223, 5 pins, pitch 3.5mm, size 18.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/20223.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 20223 pitch 3.5mm size 18.2x7mm^2 drill 1.2mm pad 2.4mm +0 +5 +5 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x05_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10696, vertical (cable from top), 5 pins, pitch 3.5mm, size 18.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10696.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10696 vertical pitch 3.5mm size 18.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x06_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 19964, 6 pins, pitch 3.5mm, size 21.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/19964.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 19964 pitch 3.5mm size 21.7x7mm^2 drill 1.2mm pad 2.4mm +0 +6 +6 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x06_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10697, vertical (cable from top), 6 pins, pitch 3.5mm, size 22x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10697.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10697 vertical pitch 3.5mm size 22x8.3mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x07_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10684, 7 pins, pitch 3.5mm, size 25.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10684.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10684 pitch 3.5mm size 25.2x7mm^2 drill 1.2mm pad 2.4mm +0 +7 +7 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x07_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10698, vertical (cable from top), 7 pins, pitch 3.5mm, size 25.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10698.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10698 vertical pitch 3.5mm size 25.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x08_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 19965, 8 pins, pitch 3.5mm, size 28.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/19965.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 19965 pitch 3.5mm size 28.7x7mm^2 drill 1.2mm pad 2.4mm +0 +8 +8 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x08_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10699, vertical (cable from top), 8 pins, pitch 3.5mm, size 29x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10699.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10699 vertical pitch 3.5mm size 29x8.3mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x09_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10686, 9 pins, pitch 3.5mm, size 32.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10686.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10686 pitch 3.5mm size 32.2x7mm^2 drill 1.2mm pad 2.4mm +0 +9 +9 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x09_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10700, vertical (cable from top), 9 pins, pitch 3.5mm, size 32.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10700.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10700 vertical pitch 3.5mm size 32.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x10_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10687, 10 pins, pitch 3.5mm, size 35.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10687.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10687 pitch 3.5mm size 35.7x7mm^2 drill 1.2mm pad 2.4mm +0 +10 +10 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x10_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10701, vertical (cable from top), 10 pins, pitch 3.5mm, size 36x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10701.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10701 vertical pitch 3.5mm size 36x8.3mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x11_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10688, 11 pins, pitch 3.5mm, size 39.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10688.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10688 pitch 3.5mm size 39.2x7mm^2 drill 1.2mm pad 2.4mm +0 +11 +11 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x11_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10702, vertical (cable from top), 11 pins, pitch 3.5mm, size 39.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10702.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10702 vertical pitch 3.5mm size 39.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x12_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10689, 12 pins, pitch 3.5mm, size 42.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10689.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10689 pitch 3.5mm size 42.7x7mm^2 drill 1.2mm pad 2.4mm +0 +12 +12 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x12_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10703, vertical (cable from top), 12 pins, pitch 3.5mm, size 43x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10703.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10703 vertical pitch 3.5mm size 43x8.3mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x13_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10690, 13 pins, pitch 3.5mm, size 46.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10690.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10690 pitch 3.5mm size 46.2x7mm^2 drill 1.2mm pad 2.4mm +0 +13 +13 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x13_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10704, vertical (cable from top), 13 pins, pitch 3.5mm, size 46.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10704.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10704 vertical pitch 3.5mm size 46.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x14_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10691, 14 pins, pitch 3.5mm, size 49.7x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10691.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10691 pitch 3.5mm size 49.7x7mm^2 drill 1.2mm pad 2.4mm +0 +14 +14 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x14_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10705, vertical (cable from top), 14 pins, pitch 3.5mm, size 50x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10705.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10705 vertical pitch 3.5mm size 50x8.3mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x15_P3.50mm_Horizontal +Terminal Block 4Ucon ItemNo. 10692, 15 pins, pitch 3.5mm, size 53.2x7mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.4uconnector.com/online/object/4udrawing/10692.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10692 pitch 3.5mm size 53.2x7mm^2 drill 1.2mm pad 2.4mm +0 +15 +15 +TerminalBlock_4Ucon +TerminalBlock_4Ucon_1x15_P3.50mm_Vertical +Terminal Block 4Ucon ItemNo. 10706, vertical (cable from top), 15 pins, pitch 3.5mm, size 53.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.4uconnector.com/online/object/4udrawing/10706.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon +THT Terminal Block 4Ucon ItemNo. 10706 vertical pitch 3.5mm size 53.5x8.3mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Altech +Altech_AK300_1x02_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +2 +2 +TerminalBlock_Altech +Altech_AK300_1x03_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +3 +3 +TerminalBlock_Altech +Altech_AK300_1x04_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +4 +4 +TerminalBlock_Altech +Altech_AK300_1x05_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +5 +5 +TerminalBlock_Altech +Altech_AK300_1x06_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +6 +6 +TerminalBlock_Altech +Altech_AK300_1x07_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +7 +7 +TerminalBlock_Altech +Altech_AK300_1x08_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +8 +8 +TerminalBlock_Altech +Altech_AK300_1x09_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +9 +9 +TerminalBlock_Altech +Altech_AK300_1x10_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +10 +10 +TerminalBlock_Altech +Altech_AK300_1x11_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +11 +11 +TerminalBlock_Altech +Altech_AK300_1x12_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +12 +12 +TerminalBlock_Altech +Altech_AK300_1x13_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +13 +13 +TerminalBlock_Altech +Altech_AK300_1x14_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +14 +14 +TerminalBlock_Altech +Altech_AK300_1x15_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +15 +15 +TerminalBlock_Altech +Altech_AK300_1x16_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +16 +16 +TerminalBlock_Altech +Altech_AK300_1x17_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +17 +17 +TerminalBlock_Altech +Altech_AK300_1x18_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +18 +18 +TerminalBlock_Altech +Altech_AK300_1x19_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +19 +19 +TerminalBlock_Altech +Altech_AK300_1x20_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +20 +20 +TerminalBlock_Altech +Altech_AK300_1x21_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +21 +21 +TerminalBlock_Altech +Altech_AK300_1x22_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +22 +22 +TerminalBlock_Altech +Altech_AK300_1x23_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +23 +23 +TerminalBlock_Altech +Altech_AK300_1x24_P5.00mm_45-Degree +Altech AK300 serie terminal block (Script generated with StandardBox.py) (http://www.altechcorp.com/PDFS/PCBMETRC.PDF) +Altech AK300 serie connector +0 +24 +24 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-02_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +2 +2 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-03_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +3 +3 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-04_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +4 +4 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-05_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +5 +5 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-06_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +6 +6 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-07_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +7 +7 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-08_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +8 +8 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-09_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +9 +9 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-10_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +10 +10 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-11_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +11 +11 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-12_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +12 +12 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-13_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +13 +13 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-14_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +14 +14 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-15_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +15 +15 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-16_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +16 +16 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-17_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +17 +17 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-18_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +18 +18 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-19_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +19 +19 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-20_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +20 +20 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-21_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +21 +21 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-22_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +22 +22 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-23_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +23 +23 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-24_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +24 +24 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-25_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +25 +25 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-26_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +26 +26 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-27_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +27 +27 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-28_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +28 +28 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-29_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +29 +29 +TerminalBlock_Dinkle +TerminalBlock_Dinkle_DT-55-B01X-30_P10.00mm +Dinkle DT-55-B01X Terminal Block pitch 10.00mm https://www.dinkle.com/en/terminal/DT-55-B01W-XX +Dinkle DT-55-B01X Terminal Block pitch 10.00mm +0 +30 +30 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360271_1x01_Horizontal_ScrewM3.0_Boxed +single screw terminal block Metz Connect 360271, block size 9x7.3mm^2, drill diamater 1.5mm, 1 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 134, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360271 size 9x7.3mm^2 drill 1.5mm pad 3mm +0 +1 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360272_1x01_Horizontal_ScrewM2.6 +single screw terminal block Metz Connect 360272, block size 4x4mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 131, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360272 size 4x4mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360273_1x01_Horizontal_ScrewM2.6_WireProtection +single screw terminal block Metz Connect 360273, block size 5x4mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 131, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360273 size 5x4mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360291_1x01_Horizontal_ScrewM3.0_Boxed +single screw terminal block Metz Connect 360291, block size 9x7.3mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 133, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360291 size 9x7.3mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360322_1x01_Horizontal_ScrewM3.0_WireProtection +single screw terminal block Metz Connect 360322, block size 6x4mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 133, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360322 size 6x4mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360381_1x01_Horizontal_ScrewM3.0 +single screw terminal block Metz Connect 360381, block size 5x5mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 133, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360381 size 5x5mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360410_1x01_Horizontal_ScrewM3.0 +single screw terminal block Metz Connect 360410, block size 5x5mm^2, drill diamater 1.5mm, 2 pads, pad diameter 3mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 132, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360410 size 5x5mm^2 drill 1.5mm pad 3mm +0 +2 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_360425_1x01_Horizontal_ScrewM4.0_Boxed +single screw terminal block Metz Connect 360425, block size 9x9mm^2, drill diamater 1.6mm, 4 pads, pad diameter 3.2mm, see http://www.metz-connect.com/de/system/files/METZ_CONNECT_U_Contact_Katalog_Anschlusssysteme_fuer_Leiterplatten_DE_31_07_2017_OFF_024803.pdf?language=en page 134, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT single screw terminal block Metz Connect 360425 size 9x9mm^2 drill 1.6mm pad 3.2mm +0 +4 +1 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05502HBWC_1x02_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05502HBWC, 2 pins, pitch 5mm, size 10x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05502HBWC pitch 5mm size 10x10.5mm^2 drill 1.4mm pad 2.8mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05503HBWC_1x03_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05503HBWC, 3 pins, pitch 5mm, size 15x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05503HBWC pitch 5mm size 15x10.5mm^2 drill 1.4mm pad 2.8mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05504HBWC_1x04_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05504HBWC, 4 pins, pitch 5mm, size 20x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05504HBWC pitch 5mm size 20x10.5mm^2 drill 1.4mm pad 2.8mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05505HBWC_1x05_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05505HBWC, 5 pins, pitch 5mm, size 25x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05505HBWC pitch 5mm size 25x10.5mm^2 drill 1.4mm pad 2.8mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type011_RT05506HBWC_1x06_P5.00mm_Horizontal +terminal block Metz Connect Type011_RT05506HBWC, 6 pins, pitch 5mm, size 30x10.5mm^2, drill diamater 1.4mm, pad diameter 2.8mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310111_RT055xxHBLC_OFF-022717S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type011_RT05506HBWC pitch 5mm size 30x10.5mm^2 drill 1.4mm pad 2.8mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type055_RT01502HDWU_1x02_P5.00mm_Horizontal +terminal block Metz Connect Type055_RT01502HDWU, 2 pins, pitch 5mm, size 10x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310551_RT015xxHDWU_OFF-022723S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type055_RT01502HDWU pitch 5mm size 10x8mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type055_RT01503HDWU_1x03_P5.00mm_Horizontal +terminal block Metz Connect Type055_RT01503HDWU, 3 pins, pitch 5mm, size 15x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310551_RT015xxHDWU_OFF-022723S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type055_RT01503HDWU pitch 5mm size 15x8mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type055_RT01504HDWU_1x04_P5.00mm_Horizontal +terminal block Metz Connect Type055_RT01504HDWU, 4 pins, pitch 5mm, size 20x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310551_RT015xxHDWU_OFF-022723S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type055_RT01504HDWU pitch 5mm size 20x8mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06302HBWC_1x02_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06302HBWC, 2 pins, pitch 3.5mm, size 7x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06302HBWC pitch 3.5mm size 7x6.5mm^2 drill 1.2mm pad 2.3mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06303HBWC_1x03_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06303HBWC, 3 pins, pitch 3.5mm, size 10.5x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06303HBWC pitch 3.5mm size 10.5x6.5mm^2 drill 1.2mm pad 2.3mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06304HBWC_1x04_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06304HBWC, 4 pins, pitch 3.5mm, size 14x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06304HBWC pitch 3.5mm size 14x6.5mm^2 drill 1.2mm pad 2.3mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06305HBWC_1x05_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06305HBWC, 5 pins, pitch 3.5mm, size 17.5x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06305HBWC pitch 3.5mm size 17.5x6.5mm^2 drill 1.2mm pad 2.3mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type059_RT06306HBWC_1x06_P3.50mm_Horizontal +terminal block Metz Connect Type059_RT06306HBWC, 6 pins, pitch 3.5mm, size 21x6.5mm^2, drill diamater 1.2mm, pad diameter 2.3mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310591_RT063xxHBWC_OFF-022684T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type059_RT06306HBWC pitch 3.5mm size 21x6.5mm^2 drill 1.2mm pad 2.3mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01902HDWC_1x02_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01902HDWC, 2 pins, pitch 10mm, size 15.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01902HDWC pitch 10mm size 15.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01903HDWC_1x03_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01903HDWC, 3 pins, pitch 10mm, size 25.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01903HDWC pitch 10mm size 25.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01904HDWC_1x04_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01904HDWC, 4 pins, pitch 10mm, size 35.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01904HDWC pitch 10mm size 35.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type067_RT01905HDWC_1x05_P10.00mm_Horizontal +terminal block Metz Connect Type067_RT01905HDWC, 5 pins, pitch 10mm, size 45.8x8.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type067_RT01905HDWC pitch 10mm size 45.8x8.2mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type073_RT02602HBLU_1x02_P5.08mm_Horizontal +terminal block Metz Connect Type073_RT02602HBLU, 2 pins, pitch 5.08mm, size 10.2x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310731_RT026xxHBLU_OFF-022792U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type073_RT02602HBLU pitch 5.08mm size 10.2x11mm^2 drill 1.4mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type073_RT02603HBLU_1x03_P5.08mm_Horizontal +terminal block Metz Connect Type073_RT02603HBLU, 3 pins, pitch 5.08mm, size 15.2x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310731_RT026xxHBLU_OFF-022792U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type073_RT02603HBLU pitch 5.08mm size 15.2x11mm^2 drill 1.4mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03402HBLC_1x02_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03402HBLC, 2 pins, pitch 3.81mm, size 7.51x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03402HBLC pitch 3.81mm size 7.51x7.3mm^2 drill 0.7mm pad 1.4mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03403HBLC_1x03_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03403HBLC, 3 pins, pitch 3.81mm, size 11.3x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03403HBLC pitch 3.81mm size 11.3x7.3mm^2 drill 0.7mm pad 1.4mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03404HBLC_1x04_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03404HBLC, 4 pins, pitch 3.81mm, size 15.1x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03404HBLC pitch 3.81mm size 15.1x7.3mm^2 drill 0.7mm pad 1.4mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03405HBLC_1x05_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03405HBLC, 5 pins, pitch 3.81mm, size 18.9x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03405HBLC pitch 3.81mm size 18.9x7.3mm^2 drill 0.7mm pad 1.4mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type086_RT03406HBLC_1x06_P3.81mm_Horizontal +terminal block Metz Connect Type086_RT03406HBLC, 6 pins, pitch 3.81mm, size 22.8x7.3mm^2, drill diamater 0.7mm, pad diameter 1.4mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310861_RT034xxHBLC_OFF-026114K.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type086_RT03406HBLC pitch 3.81mm size 22.8x7.3mm^2 drill 0.7mm pad 1.4mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03502HBLU_1x02_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03502HBLU, 2 pins, pitch 5mm, size 10x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03502HBLU pitch 5mm size 10x8.3mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03503HBLU_1x03_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03503HBLU, 3 pins, pitch 5mm, size 15x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03503HBLU pitch 5mm size 15x8.3mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03504HBLU_1x04_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03504HBLU, 4 pins, pitch 5mm, size 20x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03504HBLU pitch 5mm size 20x8.3mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03505HBLU_1x05_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03505HBLU, 5 pins, pitch 5mm, size 25x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03505HBLU pitch 5mm size 25x8.3mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type094_RT03506HBLU_1x06_P5.00mm_Horizontal +terminal block Metz Connect Type094_RT03506HBLU, 6 pins, pitch 5mm, size 30x8.3mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/ru/system/files/productfiles/Data_sheet_310941_RT035xxHBLU_OFF-022742T.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type094_RT03506HBLU pitch 5mm size 30x8.3mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01602HBWC_1x02_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01602HBWC, 2 pins, pitch 5.08mm, size 10.2x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01602HBWC pitch 5.08mm size 10.2x8mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01603HBWC_1x03_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01603HBWC, 3 pins, pitch 5.08mm, size 15.2x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01603HBWC pitch 5.08mm size 15.2x8mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01604HBWC_1x04_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01604HBWC, 4 pins, pitch 5.08mm, size 20.3x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01604HBWC pitch 5.08mm size 20.3x8mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01605HBWC_1x05_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01605HBWC, 5 pins, pitch 5.08mm, size 25.4x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01605HBWC pitch 5.08mm size 25.4x8mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type101_RT01606HBWC_1x06_P5.08mm_Horizontal +terminal block Metz Connect Type101_RT01606HBWC, 6 pins, pitch 5.08mm, size 30.5x8mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311011_RT016xxHBWC_OFF-022771S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type101_RT01606HBWC pitch 5.08mm size 30.5x8mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13702HBWC_1x02_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13702HBWC, 2 pins, pitch 7.5mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13702HBWC pitch 7.5mm size 15x9mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13703HBWC_1x03_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13703HBWC, 3 pins, pitch 7.5mm, size 22.5x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13703HBWC pitch 7.5mm size 22.5x9mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13704HBWC_1x04_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13704HBWC, 4 pins, pitch 7.5mm, size 30x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13704HBWC pitch 7.5mm size 30x9mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13705HBWC_1x05_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13705HBWC, 5 pins, pitch 7.5mm, size 37.5x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13705HBWC pitch 7.5mm size 37.5x9mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type171_RT13706HBWC_1x06_P7.50mm_Horizontal +terminal block Metz Connect Type171_RT13706HBWC, 6 pins, pitch 7.5mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311711_RT137xxHBWC_OFF-022811Q.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type171_RT13706HBWC pitch 7.5mm size 45x9mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02702HBLC_1x02_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02702HBLC, 2 pins, pitch 7.5mm, size 15x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02702HBLC pitch 7.5mm size 15x11mm^2 drill 1.4mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02703HBLC_1x03_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02703HBLC, 3 pins, pitch 7.5mm, size 22.5x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02703HBLC pitch 7.5mm size 22.5x11mm^2 drill 1.4mm pad 2.6mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02704HBLC_1x04_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02704HBLC, 4 pins, pitch 7.5mm, size 30x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02704HBLC pitch 7.5mm size 30x11mm^2 drill 1.4mm pad 2.6mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02705HBLC_1x05_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02705HBLC, 5 pins, pitch 7.5mm, size 37.5x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02705HBLC pitch 7.5mm size 37.5x11mm^2 drill 1.4mm pad 2.6mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type175_RT02706HBLC_1x06_P7.50mm_Horizontal +terminal block Metz Connect Type175_RT02706HBLC, 6 pins, pitch 7.5mm, size 45x11mm^2, drill diamater 1.4mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_311751_RT027xxHBLC_OFF-022814U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type175_RT02706HBLC pitch 7.5mm size 45x11mm^2 drill 1.4mm pad 2.6mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04502UBLC_1x02_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04502UBLC, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 10x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04502UBLC 45Degree pitch 5mm size 10x12.5mm^2 drill 1.4mm pad 2.7mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04503UBLC_1x03_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04503UBLC, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 15x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04503UBLC 45Degree pitch 5mm size 15x12.5mm^2 drill 1.4mm pad 2.7mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04504UBLC_1x04_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04504UBLC, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 20x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04504UBLC 45Degree pitch 5mm size 20x12.5mm^2 drill 1.4mm pad 2.7mm +0 +4 +4 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04505UBLC_1x05_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04505UBLC, 45Degree (cable under 45degree), 5 pins, pitch 5mm, size 25x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04505UBLC 45Degree pitch 5mm size 25x12.5mm^2 drill 1.4mm pad 2.7mm +0 +5 +5 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type205_RT04506UBLC_1x06_P5.00mm_45Degree +terminal block Metz Connect Type205_RT04506UBLC, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 30x12.5mm^2, drill diamater 1.4mm, pad diameter 2.7mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_312051_RT045xxUBLC_OFF-022759T.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type205_RT04506UBLC 45Degree pitch 5mm size 30x12.5mm^2 drill 1.4mm pad 2.7mm +0 +6 +6 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type701_RT11L02HGLU_1x02_P6.35mm_Horizontal +terminal block Metz Connect Type701_RT11L02HGLU, 2 pins, pitch 6.35mm, size 12.7x12.5mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317011_RT11LxxHGLU_OFF-022798U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type701_RT11L02HGLU pitch 6.35mm size 12.7x12.5mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type701_RT11L03HGLU_1x03_P6.35mm_Horizontal +terminal block Metz Connect Type701_RT11L03HGLU, 3 pins, pitch 6.35mm, size 19x12.5mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317011_RT11LxxHGLU_OFF-022798U.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type701_RT11L03HGLU pitch 6.35mm size 19x12.5mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type703_RT10N02HGLU_1x02_P9.52mm_Horizontal +terminal block Metz Connect Type703_RT10N02HGLU, 2 pins, pitch 9.52mm, size 19x12.5mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317031_RT10NxxHGLU_OFF-022897S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type703_RT10N02HGLU pitch 9.52mm size 19x12.5mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_MetzConnect +TerminalBlock_MetzConnect_Type703_RT10N03HGLU_1x03_P9.52mm_Horizontal +terminal block Metz Connect Type703_RT10N03HGLU, 3 pins, pitch 9.52mm, size 28.6x12.5mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_317031_RT10NxxHGLU_OFF-022897S.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_MetzConnect +THT terminal block Metz Connect Type703_RT10N03HGLU pitch 9.52mm size 28.6x12.5mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Philmore +TerminalBlock_Philmore_TB132_1x02_P5.00mm_Horizontal +Terminal Block Philmore , 2 pins, pitch 5mm, size 10x10.2mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.philmore-datak.com/mc/Page%20197.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Philmore +THT Terminal Block Philmore pitch 5mm size 10x10.2mm^2 drill 1.2mm pad 2.4mm +0 +2 +2 +TerminalBlock_Philmore +TerminalBlock_Philmore_TB133_1x03_P5.00mm_Horizontal +Terminal Block Philmore , 3 pins, pitch 5mm, size 15x10.2mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see http://www.philmore-datak.com/mc/Page%20197.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Philmore +THT Terminal Block Philmore pitch 5mm size 15x10.2mm^2 drill 1.2mm pad 2.4mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-2-5.08_1x02_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-2-5.08, 2 pins, pitch 5.08mm, size 10.2x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-2-5.08 pitch 5.08mm size 10.2x9.8mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-2_1x02_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-2, 2 pins, pitch 5mm, size 10x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-2 pitch 5mm size 10x9.8mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-3-5.08_1x03_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-3-5.08, 3 pins, pitch 5.08mm, size 15.2x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-3-5.08 pitch 5.08mm size 15.2x9.8mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-3_1x03_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-3, 3 pins, pitch 5mm, size 15x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-3 pitch 5mm size 15x9.8mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-4-5.08_1x04_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-4-5.08, 4 pins, pitch 5.08mm, size 20.3x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-4-5.08 pitch 5.08mm size 20.3x9.8mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-4_1x04_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-4, 4 pins, pitch 5mm, size 20x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-4 pitch 5mm size 20x9.8mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-5-5.08_1x05_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-5-5.08, 5 pins, pitch 5.08mm, size 25.4x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-5-5.08 pitch 5.08mm size 25.4x9.8mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-5_1x05_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-5, 5 pins, pitch 5mm, size 25x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-5 pitch 5mm size 25x9.8mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-6-5.08_1x06_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-6-5.08, 6 pins, pitch 5.08mm, size 30.5x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-6-5.08 pitch 5.08mm size 30.5x9.8mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-6_1x06_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-6, 6 pins, pitch 5mm, size 30x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-6 pitch 5mm size 30x9.8mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-7-5.08_1x07_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-7-5.08, 7 pins, pitch 5.08mm, size 35.6x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-7-5.08 pitch 5.08mm size 35.6x9.8mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-7_1x07_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-7, 7 pins, pitch 5mm, size 35x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-7 pitch 5mm size 35x9.8mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-8-5.08_1x08_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-8-5.08, 8 pins, pitch 5.08mm, size 40.6x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-8-5.08 pitch 5.08mm size 40.6x9.8mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-8_1x08_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-8, 8 pins, pitch 5mm, size 40x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-8 pitch 5mm size 40x9.8mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-9-5.08_1x09_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-9-5.08, 9 pins, pitch 5.08mm, size 45.7x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-9-5.08 pitch 5.08mm size 45.7x9.8mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-9_1x09_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-9, 9 pins, pitch 5mm, size 45x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-9 pitch 5mm size 45x9.8mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-10-5.08_1x10_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-10-5.08, 10 pins, pitch 5.08mm, size 50.8x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-10-5.08 pitch 5.08mm size 50.8x9.8mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-10_1x10_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-10, 10 pins, pitch 5mm, size 50x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-10 pitch 5mm size 50x9.8mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-11-5.08_1x11_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-11-5.08, 11 pins, pitch 5.08mm, size 55.9x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-11-5.08 pitch 5.08mm size 55.9x9.8mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-11_1x11_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-11, 11 pins, pitch 5mm, size 55x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-11 pitch 5mm size 55x9.8mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-12-5.08_1x12_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-12-5.08, 12 pins, pitch 5.08mm, size 61x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-12-5.08 pitch 5.08mm size 61x9.8mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-12_1x12_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-12, 12 pins, pitch 5mm, size 60x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-12 pitch 5mm size 60x9.8mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-13-5.08_1x13_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-13-5.08, 13 pins, pitch 5.08mm, size 66x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-13-5.08 pitch 5.08mm size 66x9.8mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-13_1x13_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-13, 13 pins, pitch 5mm, size 65x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-13 pitch 5mm size 65x9.8mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-14-5.08_1x14_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-14-5.08, 14 pins, pitch 5.08mm, size 71.1x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-14-5.08 pitch 5.08mm size 71.1x9.8mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-14_1x14_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-14, 14 pins, pitch 5mm, size 70x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-14 pitch 5mm size 70x9.8mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-15-5.08_1x15_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-15-5.08, 15 pins, pitch 5.08mm, size 76.2x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-15-5.08 pitch 5.08mm size 76.2x9.8mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-15_1x15_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-15, 15 pins, pitch 5mm, size 75x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-15 pitch 5mm size 75x9.8mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-16-5.08_1x16_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-1,5-16-5.08, 16 pins, pitch 5.08mm, size 81.3x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-16-5.08 pitch 5.08mm size 81.3x9.8mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-1,5-16_1x16_P5.00mm_Horizontal +Terminal Block Phoenix MKDS-1,5-16, 16 pins, pitch 5mm, size 80x9.8mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-1,5-16 pitch 5mm size 80x9.8mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-2-5.08_1x02_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-2-5.08, 2 pins, pitch 5.08mm, size 10.2x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-2-5.08 pitch 5.08mm size 10.2x11.2mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-3-5.08_1x03_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-3-5.08, 3 pins, pitch 5.08mm, size 15.2x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-3-5.08 pitch 5.08mm size 15.2x11.2mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-4-5.08_1x04_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-4-5.08, 4 pins, pitch 5.08mm, size 20.3x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-4-5.08 pitch 5.08mm size 20.3x11.2mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-5-5.08_1x05_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-5-5.08, 5 pins, pitch 5.08mm, size 25.4x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-5-5.08 pitch 5.08mm size 25.4x11.2mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-6-5.08_1x06_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-6-5.08, 6 pins, pitch 5.08mm, size 30.5x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-6-5.08 pitch 5.08mm size 30.5x11.2mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-7-5.08_1x07_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-7-5.08, 7 pins, pitch 5.08mm, size 35.6x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-7-5.08 pitch 5.08mm size 35.6x11.2mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-8-5.08_1x08_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-8-5.08, 8 pins, pitch 5.08mm, size 40.6x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-8-5.08 pitch 5.08mm size 40.6x11.2mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-9-5.08_1x09_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-9-5.08, 9 pins, pitch 5.08mm, size 45.7x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-9-5.08 pitch 5.08mm size 45.7x11.2mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-10-5.08_1x10_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-10-5.08, 10 pins, pitch 5.08mm, size 50.8x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-10-5.08 pitch 5.08mm size 50.8x11.2mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-11-5.08_1x11_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-11-5.08, 11 pins, pitch 5.08mm, size 55.9x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-11-5.08 pitch 5.08mm size 55.9x11.2mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-12-5.08_1x12_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-12-5.08, 12 pins, pitch 5.08mm, size 61x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-12-5.08 pitch 5.08mm size 61x11.2mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-13-5.08_1x13_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-13-5.08, 13 pins, pitch 5.08mm, size 66x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-13-5.08 pitch 5.08mm size 66x11.2mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-14-5.08_1x14_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-14-5.08, 14 pins, pitch 5.08mm, size 71.1x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-14-5.08 pitch 5.08mm size 71.1x11.2mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-15-5.08_1x15_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-15-5.08, 15 pins, pitch 5.08mm, size 76.2x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-15-5.08 pitch 5.08mm size 76.2x11.2mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MKDS-3-16-5.08_1x16_P5.08mm_Horizontal +Terminal Block Phoenix MKDS-3-16-5.08, 16 pins, pitch 5.08mm, size 81.3x11.2mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/2138224.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MKDS-3-16-5.08 pitch 5.08mm size 81.3x11.2mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-2-2.54_1x02_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-2-2.54, 2 pins, pitch 2.54mm, size 5.54x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725656-920552.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-2-2.54 pitch 2.54mm size 5.54x6.2mm^2 drill 1.1mm pad 2.2mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-3-2.54_1x03_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-3-2.54, 3 pins, pitch 2.54mm, size 8.08x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725656-920552.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-3-2.54 pitch 2.54mm size 8.08x6.2mm^2 drill 1.1mm pad 2.2mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-4-2.54_1x04_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-4-2.54, 4 pins, pitch 2.54mm, size 10.6x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-4-2.54 pitch 2.54mm size 10.6x6.2mm^2 drill 1.1mm pad 2.2mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-5-2.54_1x05_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-5-2.54, 5 pins, pitch 2.54mm, size 13.2x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-5-2.54 pitch 2.54mm size 13.2x6.2mm^2 drill 1.1mm pad 2.2mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-6-2.54_1x06_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-6-2.54, 6 pins, pitch 2.54mm, size 15.7x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-6-2.54 pitch 2.54mm size 15.7x6.2mm^2 drill 1.1mm pad 2.2mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-7-2.54_1x07_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-7-2.54, 7 pins, pitch 2.54mm, size 18.2x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-7-2.54 pitch 2.54mm size 18.2x6.2mm^2 drill 1.1mm pad 2.2mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-8-2.54_1x08_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-8-2.54, 8 pins, pitch 2.54mm, size 20.8x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-8-2.54 pitch 2.54mm size 20.8x6.2mm^2 drill 1.1mm pad 2.2mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-9-2.54_1x09_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-9-2.54, 9 pins, pitch 2.54mm, size 23.3x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-9-2.54 pitch 2.54mm size 23.3x6.2mm^2 drill 1.1mm pad 2.2mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-10-2.54_1x10_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-10-2.54, 10 pins, pitch 2.54mm, size 25.9x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-10-2.54 pitch 2.54mm size 25.9x6.2mm^2 drill 1.1mm pad 2.2mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-11-2.54_1x11_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-11-2.54, 11 pins, pitch 2.54mm, size 28.4x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-11-2.54 pitch 2.54mm size 28.4x6.2mm^2 drill 1.1mm pad 2.2mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_MPT-0,5-12-2.54_1x12_P2.54mm_Horizontal +Terminal Block Phoenix MPT-0,5-12-2.54, 12 pins, pitch 2.54mm, size 30.9x6.2mm^2, drill diamater 1.1mm, pad diameter 2.2mm, see http://www.mouser.com/ds/2/324/ItemDetail_1725672-916605.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix MPT-0,5-12-2.54 pitch 2.54mm size 30.9x6.2mm^2 drill 1.1mm pad 2.2mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-2-3.5-H_1x02_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-2-3.5-H, 2 pins, pitch 3.5mm, size 7x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-2-3.5-H pitch 3.5mm size 7x7.6mm^2 drill 1.2mm pad 2.4mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-2-5.0-H_1x02_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-2-5.0-H, 2 pins, pitch 5mm, size 10x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-2-5.0-H pitch 5mm size 10x9mm^2 drill 1.3mm pad 2.6mm +0 +2 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-3-3.5-H_1x03_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-3-3.5-H, 3 pins, pitch 3.5mm, size 10.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-3-3.5-H pitch 3.5mm size 10.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-3-5.0-H_1x03_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-3-5.0-H, 3 pins, pitch 5mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-3-5.0-H pitch 5mm size 15x9mm^2 drill 1.3mm pad 2.6mm +0 +3 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-4-3.5-H_1x04_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-4-3.5-H, 4 pins, pitch 3.5mm, size 14x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-4-3.5-H pitch 3.5mm size 14x7.6mm^2 drill 1.2mm pad 2.4mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-4-5.0-H_1x04_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-4-5.0-H, 4 pins, pitch 5mm, size 20x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-4-5.0-H pitch 5mm size 20x9mm^2 drill 1.3mm pad 2.6mm +0 +4 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-5-3.5-H_1x05_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-5-3.5-H, 5 pins, pitch 3.5mm, size 17.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-5-3.5-H pitch 3.5mm size 17.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-5-5.0-H_1x05_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-5-5.0-H, 5 pins, pitch 5mm, size 25x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-5-5.0-H pitch 5mm size 25x9mm^2 drill 1.3mm pad 2.6mm +0 +5 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-6-3.5-H_1x06_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-6-3.5-H, 6 pins, pitch 3.5mm, size 21x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-6-3.5-H pitch 3.5mm size 21x7.6mm^2 drill 1.2mm pad 2.4mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-6-5.0-H_1x06_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-6-5.0-H, 6 pins, pitch 5mm, size 30x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-6-5.0-H pitch 5mm size 30x9mm^2 drill 1.3mm pad 2.6mm +0 +6 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-7-3.5-H_1x07_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-7-3.5-H, 7 pins, pitch 3.5mm, size 24.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-7-3.5-H pitch 3.5mm size 24.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-7-5.0-H_1x07_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-7-5.0-H, 7 pins, pitch 5mm, size 35x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-7-5.0-H pitch 5mm size 35x9mm^2 drill 1.3mm pad 2.6mm +0 +7 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-8-3.5-H_1x08_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-8-3.5-H, 8 pins, pitch 3.5mm, size 28x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-8-3.5-H pitch 3.5mm size 28x7.6mm^2 drill 1.2mm pad 2.4mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-8-5.0-H_1x08_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-8-5.0-H, 8 pins, pitch 5mm, size 40x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-8-5.0-H pitch 5mm size 40x9mm^2 drill 1.3mm pad 2.6mm +0 +8 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-9-3.5-H_1x09_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-9-3.5-H, 9 pins, pitch 3.5mm, size 31.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-9-3.5-H pitch 3.5mm size 31.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-9-5.0-H_1x09_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-9-5.0-H, 9 pins, pitch 5mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-9-5.0-H pitch 5mm size 45x9mm^2 drill 1.3mm pad 2.6mm +0 +9 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-10-3.5-H_1x10_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-10-3.5-H, 10 pins, pitch 3.5mm, size 35x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-10-3.5-H pitch 3.5mm size 35x7.6mm^2 drill 1.2mm pad 2.4mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-10-5.0-H_1x10_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-10-5.0-H, 10 pins, pitch 5mm, size 50x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-10-5.0-H pitch 5mm size 50x9mm^2 drill 1.3mm pad 2.6mm +0 +10 +10 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-11-3.5-H_1x11_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-11-3.5-H, 11 pins, pitch 3.5mm, size 38.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-11-3.5-H pitch 3.5mm size 38.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-11-5.0-H_1x11_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-11-5.0-H, 11 pins, pitch 5mm, size 55x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-11-5.0-H pitch 5mm size 55x9mm^2 drill 1.3mm pad 2.6mm +0 +11 +11 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-12-3.5-H_1x12_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-12-3.5-H, 12 pins, pitch 3.5mm, size 42x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-12-3.5-H pitch 3.5mm size 42x7.6mm^2 drill 1.2mm pad 2.4mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-12-5.0-H_1x12_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-12-5.0-H, 12 pins, pitch 5mm, size 60x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-12-5.0-H pitch 5mm size 60x9mm^2 drill 1.3mm pad 2.6mm +0 +12 +12 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-13-3.5-H_1x13_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-13-3.5-H, 13 pins, pitch 3.5mm, size 45.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-13-3.5-H pitch 3.5mm size 45.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-13-5.0-H_1x13_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-13-5.0-H, 13 pins, pitch 5mm, size 65x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-13-5.0-H pitch 5mm size 65x9mm^2 drill 1.3mm pad 2.6mm +0 +13 +13 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-14-3.5-H_1x14_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-14-3.5-H, 14 pins, pitch 3.5mm, size 49x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-14-3.5-H pitch 3.5mm size 49x7.6mm^2 drill 1.2mm pad 2.4mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-14-5.0-H_1x14_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-14-5.0-H, 14 pins, pitch 5mm, size 70x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-14-5.0-H pitch 5mm size 70x9mm^2 drill 1.3mm pad 2.6mm +0 +14 +14 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-15-3.5-H_1x15_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-15-3.5-H, 15 pins, pitch 3.5mm, size 52.5x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-15-3.5-H pitch 3.5mm size 52.5x7.6mm^2 drill 1.2mm pad 2.4mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-15-5.0-H_1x15_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-15-5.0-H, 15 pins, pitch 5mm, size 75x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-15-5.0-H pitch 5mm size 75x9mm^2 drill 1.3mm pad 2.6mm +0 +15 +15 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-16-3.5-H_1x16_P3.50mm_Horizontal +Terminal Block Phoenix PT-1,5-16-3.5-H, 16 pins, pitch 3.5mm, size 56x7.6mm^2, drill diamater 1.2mm, pad diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-16-3.5-H pitch 3.5mm size 56x7.6mm^2 drill 1.2mm pad 2.4mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PT-1,5-16-5.0-H_1x16_P5.00mm_Horizontal +Terminal Block Phoenix PT-1,5-16-5.0-H, 16 pins, pitch 5mm, size 80x9mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.mouser.com/ds/2/324/ItemDetail_1935161-922578.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PT-1,5-16-5.0-H pitch 5mm size 80x9mm^2 drill 1.3mm pad 2.6mm +0 +16 +16 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-2,5-V-SMD_1x02-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 2 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814702/pdf +PhoenixContact PTSM0.5 2 2.5mm vertical SMD spring clamp terminal block connector +0 +4 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-2.5-H-THR_1x02_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-2-2.5-H-THR, 2 pins, pitch 2.5mm, size 7.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-2-2.5-H-THR pitch 2.5mm size 7.2x10mm^2 drill 1.2mm pad 3mm +0 +4 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-2.5-V-THR_1x02_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-2-2.5-V-THR, vertical (cable from top), 2 pins, pitch 2.5mm, size 5.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-2-2.5-V-THR vertical pitch 2.5mm size 5.5x5mm^2 drill 1.2mm pad 2mm +0 +4 +2 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-2-HV-2.5-SMD_1x02-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 2 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778696/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +4 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-2,5-V-SMD_1x03-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 3 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814715/pdf +PhoenixContact PTSM0.5 3 2.5mm vertical SMD spring clamp terminal block connector +0 +5 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-2.5-H-THR_1x03_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-3-2.5-H-THR, 3 pins, pitch 2.5mm, size 9.7x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-3-2.5-H-THR pitch 2.5mm size 9.7x10mm^2 drill 1.2mm pad 3mm +0 +6 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-2.5-V-THR_1x03_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-3-2.5-V-THR, vertical (cable from top), 3 pins, pitch 2.5mm, size 8x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-3-2.5-V-THR vertical pitch 2.5mm size 8x5mm^2 drill 1.2mm pad 2mm +0 +6 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-3-HV-2.5-SMD_1x03-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 3 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778706/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +5 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-2,5-V-SMD_1x04-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 4 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814728/pdf +PhoenixContact PTSM0.5 4 2.5mm vertical SMD spring clamp terminal block connector +0 +6 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-2.5-H-THR_1x04_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-4-2.5-H-THR, 4 pins, pitch 2.5mm, size 12.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-4-2.5-H-THR pitch 2.5mm size 12.2x10mm^2 drill 1.2mm pad 3mm +0 +8 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-2.5-V-THR_1x04_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-4-2.5-V-THR, vertical (cable from top), 4 pins, pitch 2.5mm, size 10.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-4-2.5-V-THR vertical pitch 2.5mm size 10.5x5mm^2 drill 1.2mm pad 2mm +0 +8 +4 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-4-HV-2.5-SMD_1x04-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 4 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778719/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +4 +3 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-2,5-V-SMD_1x05-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 5 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814731/pdf +PhoenixContact PTSM0.5 5 2.5mm vertical SMD spring clamp terminal block connector +0 +7 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-2.5-H-THR_1x05_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-5-2.5-H-THR, 5 pins, pitch 2.5mm, size 14.7x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-5-2.5-H-THR pitch 2.5mm size 14.7x10mm^2 drill 1.2mm pad 3mm +0 +10 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-2.5-V-THR_1x05_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-5-2.5-V-THR, vertical (cable from top), 5 pins, pitch 2.5mm, size 13x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-5-2.5-V-THR vertical pitch 2.5mm size 13x5mm^2 drill 1.2mm pad 2mm +0 +10 +5 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-5-HV-2.5-SMD_1x05-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 5 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778722/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +7 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-2,5-V-SMD_1x06-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 6 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814744/pdf +PhoenixContact PTSM0.5 6 2.5mm vertical SMD spring clamp terminal block connector +0 +8 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-2.5-H-THR_1x06_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-6-2.5-H-THR, 6 pins, pitch 2.5mm, size 17.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-6-2.5-H-THR pitch 2.5mm size 17.2x10mm^2 drill 1.2mm pad 3mm +0 +12 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-2.5-V-THR_1x06_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-6-2.5-V-THR, vertical (cable from top), 6 pins, pitch 2.5mm, size 15.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-6-2.5-V-THR vertical pitch 2.5mm size 15.5x5mm^2 drill 1.2mm pad 2mm +0 +12 +6 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-6-HV-2.5-SMD_1x06-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 6 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778735/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +8 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-2,5-V-SMD_1x07-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 7 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814757/pdf +PhoenixContact PTSM0.5 7 2.5mm vertical SMD spring clamp terminal block connector +0 +9 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-2.5-H-THR_1x07_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-7-2.5-H-THR, 7 pins, pitch 2.5mm, size 19.7x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-7-2.5-H-THR pitch 2.5mm size 19.7x10mm^2 drill 1.2mm pad 3mm +0 +14 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-2.5-V-THR_1x07_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-7-2.5-V-THR, vertical (cable from top), 7 pins, pitch 2.5mm, size 18x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-7-2.5-V-THR vertical pitch 2.5mm size 18x5mm^2 drill 1.2mm pad 2mm +0 +14 +7 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-7-HV-2.5-SMD_1x07-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 7 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778748/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +9 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-2,5-V-SMD_1x08-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 8 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1814760/pdf +PhoenixContact PTSM0.5 8 2.5mm vertical SMD spring clamp terminal block connector +0 +10 +9 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-2.5-H-THR_1x08_P2.50mm_Horizontal +Terminal Block Phoenix PTSM-0,5-8-2.5-H-THR, 8 pins, pitch 2.5mm, size 22.2x10mm^2, drill diamater 1.2mm, pad diameter 3mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556441-da-01-de-LEITERPLATTENKL__PTSM_0_5__8_2_5_H_THR.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-8-2.5-H-THR pitch 2.5mm size 22.2x10mm^2 drill 1.2mm pad 3mm +0 +16 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-2.5-V-THR_1x08_P2.50mm_Vertical +Terminal Block Phoenix PTSM-0,5-8-2.5-V-THR, vertical (cable from top), 8 pins, pitch 2.5mm, size 20.5x5mm^2, drill diamater 1.2mm, pad diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix +THT Terminal Block Phoenix PTSM-0,5-8-2.5-V-THR vertical pitch 2.5mm size 20.5x5mm^2 drill 1.2mm pad 2mm +0 +16 +8 +TerminalBlock_Phoenix +TerminalBlock_Phoenix_PTSM-0,5-8-HV-2.5-SMD_1x08-1MP_P2.50mm_Vertical +PhoenixContact PTSM0,5 8 HV 2,5mm vertical SMD spring clamp terminal block connector http://www.phoenixcontact.com/us/products/1778751/pdf +2.5mm vertical SMD spring clamp terminal block connector +0 +10 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00001_1x02_P5.00mm_Horizontal +terminal block RND 205-00001, 2 pins, pitch 5mm, size 10x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00001 pitch 5mm size 10x9mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00002_1x03_P5.00mm_Horizontal +terminal block RND 205-00002, 3 pins, pitch 5mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00002 pitch 5mm size 15x9mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00003_1x04_P5.00mm_Horizontal +terminal block RND 205-00003, 4 pins, pitch 5mm, size 20x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00003 pitch 5mm size 20x9mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00004_1x05_P5.00mm_Horizontal +terminal block RND 205-00004, 5 pins, pitch 5mm, size 25x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00004 pitch 5mm size 25x9mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00005_1x06_P5.00mm_Horizontal +terminal block RND 205-00005, 6 pins, pitch 5mm, size 30x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00005 pitch 5mm size 30x9mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00006_1x07_P5.00mm_Horizontal +terminal block RND 205-00006, 7 pins, pitch 5mm, size 35x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00006 pitch 5mm size 35x9mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00007_1x08_P5.00mm_Horizontal +terminal block RND 205-00007, 8 pins, pitch 5mm, size 40x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00007 pitch 5mm size 40x9mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00008_1x09_P5.00mm_Horizontal +terminal block RND 205-00008, 9 pins, pitch 5mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00008 pitch 5mm size 45x9mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00009_1x10_P5.00mm_Horizontal +terminal block RND 205-00009, 10 pins, pitch 5mm, size 50x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00009 pitch 5mm size 50x9mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00010_1x11_P5.00mm_Horizontal +terminal block RND 205-00010, 11 pins, pitch 5mm, size 55x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00010 pitch 5mm size 55x9mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00011_1x12_P5.00mm_Horizontal +terminal block RND 205-00011, 12 pins, pitch 5mm, size 60x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00001_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00011 pitch 5mm size 60x9mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00012_1x02_P5.00mm_Horizontal +terminal block RND 205-00012, 2 pins, pitch 5mm, size 10x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00012 pitch 5mm size 10x7.6mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00013_1x03_P5.00mm_Horizontal +terminal block RND 205-00013, 3 pins, pitch 5mm, size 15x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00013 pitch 5mm size 15x7.6mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00014_1x04_P5.00mm_Horizontal +terminal block RND 205-00014, 4 pins, pitch 5mm, size 20x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00014 pitch 5mm size 20x7.6mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00015_1x05_P5.00mm_Horizontal +terminal block RND 205-00015, 5 pins, pitch 5mm, size 25x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00015 pitch 5mm size 25x7.6mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00016_1x06_P5.00mm_Horizontal +terminal block RND 205-00016, 6 pins, pitch 5mm, size 30x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00016 pitch 5mm size 30x7.6mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00017_1x07_P5.00mm_Horizontal +terminal block RND 205-00017, 7 pins, pitch 5mm, size 35x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00017 pitch 5mm size 35x7.6mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00018_1x08_P5.00mm_Horizontal +terminal block RND 205-00018, 8 pins, pitch 5mm, size 40x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00018 pitch 5mm size 40x7.6mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00019_1x09_P5.00mm_Horizontal +terminal block RND 205-00019, 9 pins, pitch 5mm, size 45x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00019 pitch 5mm size 45x7.6mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00020_1x10_P5.00mm_Horizontal +terminal block RND 205-00020, 10 pins, pitch 5mm, size 50x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00020 pitch 5mm size 50x7.6mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00021_1x11_P5.00mm_Horizontal +terminal block RND 205-00021, 11 pins, pitch 5mm, size 55x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00021 pitch 5mm size 55x7.6mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00022_1x12_P5.00mm_Horizontal +terminal block RND 205-00022, 12 pins, pitch 5mm, size 60x7.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00022 pitch 5mm size 60x7.6mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00023_1x02_P10.00mm_Horizontal +terminal block RND 205-00023, 2 pins, pitch 10mm, size 15x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00023 pitch 10mm size 15x9mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00024_1x03_P10.00mm_Horizontal +terminal block RND 205-00024, 3 pins, pitch 10mm, size 25x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00024 pitch 10mm size 25x9mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00025_1x04_P10.00mm_Horizontal +terminal block RND 205-00025, 4 pins, pitch 10mm, size 35x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00025 pitch 10mm size 35x9mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00026_1x05_P10.00mm_Horizontal +terminal block RND 205-00026, 5 pins, pitch 10mm, size 45x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00026 pitch 10mm size 45x9mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00027_1x06_P10.00mm_Horizontal +terminal block RND 205-00027, 6 pins, pitch 10mm, size 55x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00027 pitch 10mm size 55x9mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00028_1x07_P10.00mm_Horizontal +terminal block RND 205-00028, 7 pins, pitch 10mm, size 65x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00028 pitch 10mm size 65x9mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00029_1x08_P10.00mm_Horizontal +terminal block RND 205-00029, 8 pins, pitch 10mm, size 75x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00029 pitch 10mm size 75x9mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00030_1x09_P10.00mm_Horizontal +terminal block RND 205-00030, 9 pins, pitch 10mm, size 85x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00030 pitch 10mm size 85x9mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00031_1x10_P10.00mm_Horizontal +terminal block RND 205-00031, 10 pins, pitch 10mm, size 95x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00031 pitch 10mm size 95x9mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00032_1x11_P10.00mm_Horizontal +terminal block RND 205-00032, 11 pins, pitch 10mm, size 105x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00032 pitch 10mm size 105x9mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00033_1x12_P10.00mm_Horizontal +terminal block RND 205-00033, 12 pins, pitch 10mm, size 115x9mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00033 pitch 10mm size 115x9mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00045_1x02_P5.00mm_Horizontal +terminal block RND 205-00045, 2 pins, pitch 5mm, size 10x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00045 pitch 5mm size 10x8.1mm^2 drill 1.1mm pad 2.1mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00046_1x03_P5.00mm_Horizontal +terminal block RND 205-00046, 3 pins, pitch 5mm, size 15x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00046 pitch 5mm size 15x8.1mm^2 drill 1.1mm pad 2.1mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00047_1x04_P5.00mm_Horizontal +terminal block RND 205-00047, 4 pins, pitch 5mm, size 20x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00047 pitch 5mm size 20x8.1mm^2 drill 1.1mm pad 2.1mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00048_1x05_P5.00mm_Horizontal +terminal block RND 205-00048, 5 pins, pitch 5mm, size 25x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00048 pitch 5mm size 25x8.1mm^2 drill 1.1mm pad 2.1mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00049_1x06_P5.00mm_Horizontal +terminal block RND 205-00049, 6 pins, pitch 5mm, size 30x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00049 pitch 5mm size 30x8.1mm^2 drill 1.1mm pad 2.1mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00050_1x07_P5.00mm_Horizontal +terminal block RND 205-00050, 7 pins, pitch 5mm, size 35x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00050 pitch 5mm size 35x8.1mm^2 drill 1.1mm pad 2.1mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00051_1x08_P5.00mm_Horizontal +terminal block RND 205-00051, 8 pins, pitch 5mm, size 40x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00051 pitch 5mm size 40x8.1mm^2 drill 1.1mm pad 2.1mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00052_1x09_P5.00mm_Horizontal +terminal block RND 205-00052, 9 pins, pitch 5mm, size 45x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00052 pitch 5mm size 45x8.1mm^2 drill 1.1mm pad 2.1mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00053_1x10_P5.00mm_Horizontal +terminal block RND 205-00053, 10 pins, pitch 5mm, size 50x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00053 pitch 5mm size 50x8.1mm^2 drill 1.1mm pad 2.1mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00054_1x11_P5.00mm_Horizontal +terminal block RND 205-00054, 11 pins, pitch 5mm, size 55x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00054 pitch 5mm size 55x8.1mm^2 drill 1.1mm pad 2.1mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00055_1x12_P5.00mm_Horizontal +terminal block RND 205-00055, 12 pins, pitch 5mm, size 60x8.1mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00055 pitch 5mm size 60x8.1mm^2 drill 1.1mm pad 2.1mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00056_1x02_P5.00mm_45Degree +terminal block RND 205-00056, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 10x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00056 45Degree pitch 5mm size 10x12.6mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00057_1x03_P5.00mm_45Degree +terminal block RND 205-00057, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 15x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00057 45Degree pitch 5mm size 15x12.6mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00058_1x04_P5.00mm_45Degree +terminal block RND 205-00058, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 20x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00058 45Degree pitch 5mm size 20x12.6mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00059_1x05_P5.00mm_45Degree +terminal block RND 205-00059, 45Degree (cable under 45degree), 5 pins, pitch 5mm, size 25x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00059 45Degree pitch 5mm size 25x12.6mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00060_1x06_P5.00mm_45Degree +terminal block RND 205-00060, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 30x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00060 45Degree pitch 5mm size 30x12.6mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00061_1x07_P5.00mm_45Degree +terminal block RND 205-00061, 45Degree (cable under 45degree), 7 pins, pitch 5mm, size 35x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00061 45Degree pitch 5mm size 35x12.6mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00062_1x08_P5.00mm_45Degree +terminal block RND 205-00062, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 40x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00062 45Degree pitch 5mm size 40x12.6mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00063_1x09_P5.00mm_45Degree +terminal block RND 205-00063, 45Degree (cable under 45degree), 9 pins, pitch 5mm, size 45x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00063 45Degree pitch 5mm size 45x12.6mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00064_1x10_P5.00mm_45Degree +terminal block RND 205-00064, 45Degree (cable under 45degree), 10 pins, pitch 5mm, size 50x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00064 45Degree pitch 5mm size 50x12.6mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00065_1x11_P5.00mm_45Degree +terminal block RND 205-00065, 45Degree (cable under 45degree), 11 pins, pitch 5mm, size 55x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00065 45Degree pitch 5mm size 55x12.6mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00066_1x12_P5.00mm_45Degree +terminal block RND 205-00066, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 60x12.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00066 45Degree pitch 5mm size 60x12.6mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00067_1x02_P7.50mm_Horizontal +terminal block RND 205-00067, 2 pins, pitch 7.5mm, size 15x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00067 pitch 7.5mm size 15x10.3mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00068_1x03_P7.50mm_Horizontal +terminal block RND 205-00068, 3 pins, pitch 7.5mm, size 22.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00068 pitch 7.5mm size 22.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00069_1x04_P7.50mm_Horizontal +terminal block RND 205-00069, 4 pins, pitch 7.5mm, size 30x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00069 pitch 7.5mm size 30x10.3mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00070_1x05_P7.50mm_Horizontal +terminal block RND 205-00070, 5 pins, pitch 7.5mm, size 37.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00070 pitch 7.5mm size 37.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00071_1x06_P7.50mm_Horizontal +terminal block RND 205-00071, 6 pins, pitch 7.5mm, size 45x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00071 pitch 7.5mm size 45x10.3mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00072_1x07_P7.50mm_Horizontal +terminal block RND 205-00072, 7 pins, pitch 7.5mm, size 52.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00072 pitch 7.5mm size 52.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00073_1x08_P7.50mm_Horizontal +terminal block RND 205-00073, 8 pins, pitch 7.5mm, size 60x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00073 pitch 7.5mm size 60x10.3mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00074_1x09_P7.50mm_Horizontal +terminal block RND 205-00074, 9 pins, pitch 7.5mm, size 67.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00074 pitch 7.5mm size 67.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00075_1x10_P7.50mm_Horizontal +terminal block RND 205-00075, 10 pins, pitch 7.5mm, size 75x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00075 pitch 7.5mm size 75x10.3mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00076_1x11_P7.50mm_Horizontal +terminal block RND 205-00076, 11 pins, pitch 7.5mm, size 82.5x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00076 pitch 7.5mm size 82.5x10.3mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00077_1x12_P7.50mm_Horizontal +terminal block RND 205-00077, 12 pins, pitch 7.5mm, size 90x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00067_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00077 pitch 7.5mm size 90x10.3mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00078_1x02_P10.00mm_Horizontal +terminal block RND 205-00078, 2 pins, pitch 10mm, size 15x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00078 pitch 10mm size 15x10.3mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00079_1x03_P10.00mm_Horizontal +terminal block RND 205-00079, 3 pins, pitch 10mm, size 25x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00079 pitch 10mm size 25x10.3mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00080_1x04_P10.00mm_Horizontal +terminal block RND 205-00080, 4 pins, pitch 10mm, size 35x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00080 pitch 10mm size 35x10.3mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00081_1x05_P10.00mm_Horizontal +terminal block RND 205-00081, 5 pins, pitch 10mm, size 45x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00081 pitch 10mm size 45x10.3mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00082_1x06_P10.00mm_Horizontal +terminal block RND 205-00082, 6 pins, pitch 10mm, size 55x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00082 pitch 10mm size 55x10.3mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00083_1x07_P10.00mm_Horizontal +terminal block RND 205-00083, 7 pins, pitch 10mm, size 65x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00083 pitch 10mm size 65x10.3mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00084_1x08_P10.00mm_Horizontal +terminal block RND 205-00084, 8 pins, pitch 10mm, size 75x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00084 pitch 10mm size 75x10.3mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00085_1x09_P10.00mm_Horizontal +terminal block RND 205-00085, 9 pins, pitch 10mm, size 85x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00085 pitch 10mm size 85x10.3mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00086_1x10_P10.00mm_Horizontal +terminal block RND 205-00086, 10 pins, pitch 10mm, size 95x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00086 pitch 10mm size 95x10.3mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00087_1x11_P10.00mm_Horizontal +terminal block RND 205-00087, 11 pins, pitch 10mm, size 105x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00087 pitch 10mm size 105x10.3mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00088_1x12_P10.00mm_Horizontal +terminal block RND 205-00088, 12 pins, pitch 10mm, size 115x10.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00078_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00088 pitch 10mm size 115x10.3mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00232_1x02_P5.08mm_Horizontal +terminal block RND 205-00232, 2 pins, pitch 5.08mm, size 10.2x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00232 pitch 5.08mm size 10.2x8.45mm^2 drill 1.1mm pad 2.1mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00233_1x03_P5.08mm_Horizontal +terminal block RND 205-00233, 3 pins, pitch 5.08mm, size 15.2x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00233 pitch 5.08mm size 15.2x8.45mm^2 drill 1.1mm pad 2.1mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00234_1x04_P5.08mm_Horizontal +terminal block RND 205-00234, 4 pins, pitch 5.08mm, size 20.3x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00234 pitch 5.08mm size 20.3x8.45mm^2 drill 1.1mm pad 2.1mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00235_1x05_P5.08mm_Horizontal +terminal block RND 205-00235, 5 pins, pitch 5.08mm, size 25.4x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00235 pitch 5.08mm size 25.4x8.45mm^2 drill 1.1mm pad 2.1mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00236_1x06_P5.08mm_Horizontal +terminal block RND 205-00236, 6 pins, pitch 5.08mm, size 30.5x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00236 pitch 5.08mm size 30.5x8.45mm^2 drill 1.1mm pad 2.1mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00237_1x07_P5.08mm_Horizontal +terminal block RND 205-00237, 7 pins, pitch 5.08mm, size 35.6x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00237 pitch 5.08mm size 35.6x8.45mm^2 drill 1.1mm pad 2.1mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00238_1x08_P5.08mm_Horizontal +terminal block RND 205-00238, 8 pins, pitch 5.08mm, size 40.6x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00238 pitch 5.08mm size 40.6x8.45mm^2 drill 1.1mm pad 2.1mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00239_1x09_P5.08mm_Horizontal +terminal block RND 205-00239, 9 pins, pitch 5.08mm, size 45.7x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00239 pitch 5.08mm size 45.7x8.45mm^2 drill 1.1mm pad 2.1mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00240_1x10_P5.08mm_Horizontal +terminal block RND 205-00240, 10 pins, pitch 5.08mm, size 50.8x8.45mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00232_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00240 pitch 5.08mm size 50.8x8.45mm^2 drill 1.1mm pad 2.1mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00241_1x02_P10.16mm_Horizontal +terminal block RND 205-00241, 2 pins, pitch 10.2mm, size 15.2x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00241 pitch 10.2mm size 15.2x8.3mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00242_1x03_P10.16mm_Horizontal +terminal block RND 205-00242, 3 pins, pitch 10.2mm, size 25.4x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00242 pitch 10.2mm size 25.4x8.3mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00243_1x04_P10.16mm_Horizontal +terminal block RND 205-00243, 4 pins, pitch 10.2mm, size 35.6x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00243 pitch 10.2mm size 35.6x8.3mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00244_1x05_P10.16mm_Horizontal +terminal block RND 205-00244, 5 pins, pitch 10.2mm, size 45.7x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00244 pitch 10.2mm size 45.7x8.3mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00245_1x06_P10.16mm_Horizontal +terminal block RND 205-00245, 6 pins, pitch 10.2mm, size 55.9x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00245 pitch 10.2mm size 55.9x8.3mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00246_1x07_P10.16mm_Horizontal +terminal block RND 205-00246, 7 pins, pitch 10.2mm, size 66x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00246 pitch 10.2mm size 66x8.3mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00247_1x08_P10.16mm_Horizontal +terminal block RND 205-00247, 8 pins, pitch 10.2mm, size 76.2x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00247 pitch 10.2mm size 76.2x8.3mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00248_1x09_P10.16mm_Horizontal +terminal block RND 205-00248, 9 pins, pitch 10.2mm, size 86.4x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00248 pitch 10.2mm size 86.4x8.3mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00249_1x10_P10.16mm_Horizontal +terminal block RND 205-00249, 10 pins, pitch 10.2mm, size 96.5x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00249 pitch 10.2mm size 96.5x8.3mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00250_1x11_P10.16mm_Horizontal +terminal block RND 205-00250, 11 pins, pitch 10.2mm, size 107x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00250 pitch 10.2mm size 107x8.3mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00251_1x12_P10.16mm_Horizontal +terminal block RND 205-00251, 12 pins, pitch 10.2mm, size 117x8.3mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00251 pitch 10.2mm size 117x8.3mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00276_1x02_P5.00mm_Vertical +terminal block RND 205-00078, vertical (cable from top), 2 pins, pitch 5mm, size 10x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00078 vertical pitch 5mm size 10x10mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00277_1x03_P5.00mm_Vertical +terminal block RND 205-00079, vertical (cable from top), 3 pins, pitch 5mm, size 15x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00079 vertical pitch 5mm size 15x10mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00278_1x04_P5.00mm_Vertical +terminal block RND 205-00080, vertical (cable from top), 4 pins, pitch 5mm, size 20x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00080 vertical pitch 5mm size 20x10mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00279_1x05_P5.00mm_Vertical +terminal block RND 205-00081, vertical (cable from top), 5 pins, pitch 5mm, size 25x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00081 vertical pitch 5mm size 25x10mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00280_1x06_P5.00mm_Vertical +terminal block RND 205-00082, vertical (cable from top), 6 pins, pitch 5mm, size 30x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00082 vertical pitch 5mm size 30x10mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00281_1x07_P5.00mm_Vertical +terminal block RND 205-00083, vertical (cable from top), 7 pins, pitch 5mm, size 35x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00083 vertical pitch 5mm size 35x10mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00282_1x08_P5.00mm_Vertical +terminal block RND 205-00084, vertical (cable from top), 8 pins, pitch 5mm, size 40x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00084 vertical pitch 5mm size 40x10mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00283_1x09_P5.00mm_Vertical +terminal block RND 205-00085, vertical (cable from top), 9 pins, pitch 5mm, size 45x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00085 vertical pitch 5mm size 45x10mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00284_1x10_P5.00mm_Vertical +terminal block RND 205-00086, vertical (cable from top), 10 pins, pitch 5mm, size 50x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00086 vertical pitch 5mm size 50x10mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00285_1x11_P5.00mm_Vertical +terminal block RND 205-00087, vertical (cable from top), 11 pins, pitch 5mm, size 55x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00087 vertical pitch 5mm size 55x10mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00286_1x12_P5.00mm_Vertical +terminal block RND 205-00088, vertical (cable from top), 12 pins, pitch 5mm, size 60x10mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00276_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00088 vertical pitch 5mm size 60x10mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00287_1x02_P5.08mm_Horizontal +terminal block RND 205-00287, 2 pins, pitch 5.08mm, size 10.2x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00287 pitch 5.08mm size 10.2x10.6mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00288_1x03_P5.08mm_Horizontal +terminal block RND 205-00288, 3 pins, pitch 5.08mm, size 15.2x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00288 pitch 5.08mm size 15.2x10.6mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00289_1x04_P5.08mm_Horizontal +terminal block RND 205-00289, 4 pins, pitch 5.08mm, size 20.3x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00289 pitch 5.08mm size 20.3x10.6mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00290_1x05_P5.08mm_Horizontal +terminal block RND 205-00290, 5 pins, pitch 5.08mm, size 25.4x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00290 pitch 5.08mm size 25.4x10.6mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00291_1x06_P5.08mm_Horizontal +terminal block RND 205-00291, 6 pins, pitch 5.08mm, size 30.5x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00291 pitch 5.08mm size 30.5x10.6mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00292_1x07_P5.08mm_Horizontal +terminal block RND 205-00292, 7 pins, pitch 5.08mm, size 35.6x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00292 pitch 5.08mm size 35.6x10.6mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00293_1x08_P5.08mm_Horizontal +terminal block RND 205-00293, 8 pins, pitch 5.08mm, size 40.6x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00293 pitch 5.08mm size 40.6x10.6mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00294_1x09_P5.08mm_Horizontal +terminal block RND 205-00294, 9 pins, pitch 5.08mm, size 45.7x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00294 pitch 5.08mm size 45.7x10.6mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00295_1x10_P5.08mm_Horizontal +terminal block RND 205-00295, 10 pins, pitch 5.08mm, size 50.8x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00295 pitch 5.08mm size 50.8x10.6mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00296_1x11_P5.08mm_Horizontal +terminal block RND 205-00296, 11 pins, pitch 5.08mm, size 55.9x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00296 pitch 5.08mm size 55.9x10.6mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00297_1x12_P5.08mm_Horizontal +terminal block RND 205-00297, 12 pins, pitch 5.08mm, size 61x10.6mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00287_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00297 pitch 5.08mm size 61x10.6mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_RND +TerminalBlock_RND_205-00298_1x02_P10.00mm_Horizontal +terminal block RND 205-00298, 2 pins, pitch 10mm, size 15x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00298 pitch 10mm size 15x8.1mm^2 drill 1.3mm pad 2.5mm +0 +2 +2 +TerminalBlock_RND +TerminalBlock_RND_205-00299_1x03_P10.00mm_Horizontal +terminal block RND 205-00299, 3 pins, pitch 10mm, size 25x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00299 pitch 10mm size 25x8.1mm^2 drill 1.3mm pad 2.5mm +0 +3 +3 +TerminalBlock_RND +TerminalBlock_RND_205-00300_1x04_P10.00mm_Horizontal +terminal block RND 205-00300, 4 pins, pitch 10mm, size 35x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00300 pitch 10mm size 35x8.1mm^2 drill 1.3mm pad 2.5mm +0 +4 +4 +TerminalBlock_RND +TerminalBlock_RND_205-00301_1x05_P10.00mm_Horizontal +terminal block RND 205-00301, 5 pins, pitch 10mm, size 45x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00301 pitch 10mm size 45x8.1mm^2 drill 1.3mm pad 2.5mm +0 +5 +5 +TerminalBlock_RND +TerminalBlock_RND_205-00302_1x06_P10.00mm_Horizontal +terminal block RND 205-00302, 6 pins, pitch 10mm, size 55x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00302 pitch 10mm size 55x8.1mm^2 drill 1.3mm pad 2.5mm +0 +6 +6 +TerminalBlock_RND +TerminalBlock_RND_205-00303_1x07_P10.00mm_Horizontal +terminal block RND 205-00303, 7 pins, pitch 10mm, size 65x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00303 pitch 10mm size 65x8.1mm^2 drill 1.3mm pad 2.5mm +0 +7 +7 +TerminalBlock_RND +TerminalBlock_RND_205-00304_1x08_P10.00mm_Horizontal +terminal block RND 205-00304, 8 pins, pitch 10mm, size 75x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00304 pitch 10mm size 75x8.1mm^2 drill 1.3mm pad 2.5mm +0 +8 +8 +TerminalBlock_RND +TerminalBlock_RND_205-00305_1x09_P10.00mm_Horizontal +terminal block RND 205-00305, 9 pins, pitch 10mm, size 85x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00305 pitch 10mm size 85x8.1mm^2 drill 1.3mm pad 2.5mm +0 +9 +9 +TerminalBlock_RND +TerminalBlock_RND_205-00306_1x10_P10.00mm_Horizontal +terminal block RND 205-00306, 10 pins, pitch 10mm, size 95x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00306 pitch 10mm size 95x8.1mm^2 drill 1.3mm pad 2.5mm +0 +10 +10 +TerminalBlock_RND +TerminalBlock_RND_205-00307_1x11_P10.00mm_Horizontal +terminal block RND 205-00307, 11 pins, pitch 10mm, size 105x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00307 pitch 10mm size 105x8.1mm^2 drill 1.3mm pad 2.5mm +0 +11 +11 +TerminalBlock_RND +TerminalBlock_RND_205-00308_1x12_P10.00mm_Horizontal +terminal block RND 205-00308, 12 pins, pitch 10mm, size 115x8.1mm^2, drill diamater 1.3mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00298_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND +THT terminal block RND 205-00308 pitch 10mm size 115x8.1mm^2 drill 1.3mm pad 2.5mm +0 +12 +12 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_1-282834-0_1x10_P2.54mm_Horizontal +Terminal Block TE 1-282834-0, 10 pins, pitch 2.54mm, size 25.86x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 1-282834-0 pitch 2.54mm size 25.86x6.5mm^2 drill 1.1mm pad 2.1mm +0 +10 +10 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_1-282834-1_1x11_P2.54mm_Horizontal +Terminal Block TE 1-282834-1, 11 pins, pitch 2.54mm, size 28.4x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 1-282834-1 pitch 2.54mm size 28.4x6.5mm^2 drill 1.1mm pad 2.1mm +0 +11 +11 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_1-282834-2_1x12_P2.54mm_Horizontal +Terminal Block TE 1-282834-2, 12 pins, pitch 2.54mm, size 30.94x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 1-282834-2 pitch 2.54mm size 30.94x6.5mm^2 drill 1.1mm pad 2.1mm +0 +12 +12 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-2_1x02_P2.54mm_Horizontal +Terminal Block TE 282834-2, 2 pins, pitch 2.54mm, size 5.54x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-2 pitch 2.54mm size 5.54x6.5mm^2 drill 1.1mm pad 2.1mm +0 +2 +2 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-3_1x03_P2.54mm_Horizontal +Terminal Block TE 282834-3, 3 pins, pitch 2.54mm, size 8.08x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-3 pitch 2.54mm size 8.08x6.5mm^2 drill 1.1mm pad 2.1mm +0 +3 +3 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-4_1x04_P2.54mm_Horizontal +Terminal Block TE 282834-4, 4 pins, pitch 2.54mm, size 10.620000000000001x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-4 pitch 2.54mm size 10.620000000000001x6.5mm^2 drill 1.1mm pad 2.1mm +0 +4 +4 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-5_1x05_P2.54mm_Horizontal +Terminal Block TE 282834-5, 5 pins, pitch 2.54mm, size 13.16x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-5 pitch 2.54mm size 13.16x6.5mm^2 drill 1.1mm pad 2.1mm +0 +5 +5 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-6_1x06_P2.54mm_Horizontal +Terminal Block TE 282834-6, 6 pins, pitch 2.54mm, size 15.7x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-6 pitch 2.54mm size 15.7x6.5mm^2 drill 1.1mm pad 2.1mm +0 +6 +6 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-7_1x07_P2.54mm_Horizontal +Terminal Block TE 282834-7, 7 pins, pitch 2.54mm, size 18.240000000000002x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-7 pitch 2.54mm size 18.240000000000002x6.5mm^2 drill 1.1mm pad 2.1mm +0 +7 +7 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-8_1x08_P2.54mm_Horizontal +Terminal Block TE 282834-8, 8 pins, pitch 2.54mm, size 20.78x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-8 pitch 2.54mm size 20.78x6.5mm^2 drill 1.1mm pad 2.1mm +0 +8 +8 +TerminalBlock_TE-Connectivity +TerminalBlock_TE_282834-9_1x09_P2.54mm_Horizontal +Terminal Block TE 282834-9, 9 pins, pitch 2.54mm, size 23.32x6.5mm^2, drill diamater 1.1mm, pad diameter 2.1mm, see http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F282834%7FC1%7Fpdf%7FEnglish%7FENG_CD_282834_C1.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_TE-Connectivity +THT Terminal Block TE 282834-9 pitch 2.54mm size 23.32x6.5mm^2 drill 1.1mm pad 2.1mm +0 +9 +9 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-101_1x01_P5.00mm_45Degree +Terminal Block WAGO 236-101, 45Degree (cable under 45degree), 1 pins, pitch 5mm, size 7.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-101 45Degree pitch 5mm size 7.3x14mm^2 drill 1.15mm pad 3mm +0 +1 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-102_1x02_P5.00mm_45Degree +Terminal Block WAGO 236-102, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-102 45Degree pitch 5mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-103_1x03_P5.00mm_45Degree +Terminal Block WAGO 236-103, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-103 45Degree pitch 5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +3 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-104_1x04_P5.00mm_45Degree +Terminal Block WAGO 236-104, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-104 45Degree pitch 5mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-106_1x06_P5.00mm_45Degree +Terminal Block WAGO 236-106, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-106 45Degree pitch 5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-108_1x08_P5.00mm_45Degree +Terminal Block WAGO 236-108, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-108 45Degree pitch 5mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-112_1x12_P5.00mm_45Degree +Terminal Block WAGO 236-112, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-112 45Degree pitch 5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-116_1x16_P5.00mm_45Degree +Terminal Block WAGO 236-116, 45Degree (cable under 45degree), 16 pins, pitch 5mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-116 45Degree pitch 5mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-124_1x24_P5.00mm_45Degree +Terminal Block WAGO 236-124, 45Degree (cable under 45degree), 24 pins, pitch 5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-124 45Degree pitch 5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +24 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-136_1x36_P5.00mm_45Degree +Terminal Block WAGO 236-136, 45Degree (cable under 45degree), 36 pins, pitch 5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-136 45Degree pitch 5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +36 +36 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-148_1x48_P5.00mm_45Degree +Terminal Block WAGO 236-148, 45Degree (cable under 45degree), 48 pins, pitch 5mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-148 45Degree pitch 5mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +48 +48 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-201_1x01_P7.50mm_45Degree +Terminal Block WAGO 236-201, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 9.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-201 45Degree pitch 7.5mm size 9.8x14mm^2 drill 1.15mm pad 3mm +0 +1 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-202_1x02_P7.50mm_45Degree +Terminal Block WAGO 236-202, 45Degree (cable under 45degree), 2 pins, pitch 7.5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-202 45Degree pitch 7.5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-203_1x03_P7.50mm_45Degree +Terminal Block WAGO 236-203, 45Degree (cable under 45degree), 3 pins, pitch 7.5mm, size 24.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-203 45Degree pitch 7.5mm size 24.8x14mm^2 drill 1.15mm pad 3mm +0 +3 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-204_1x04_P7.50mm_45Degree +Terminal Block WAGO 236-204, 45Degree (cable under 45degree), 4 pins, pitch 7.5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-204 45Degree pitch 7.5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-206_1x06_P7.50mm_45Degree +Terminal Block WAGO 236-206, 45Degree (cable under 45degree), 6 pins, pitch 7.5mm, size 47.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-206 45Degree pitch 7.5mm size 47.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-208_1x08_P7.50mm_45Degree +Terminal Block WAGO 236-208, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-208 45Degree pitch 7.5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-212_1x12_P7.50mm_45Degree +Terminal Block WAGO 236-212, 45Degree (cable under 45degree), 12 pins, pitch 7.5mm, size 92.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-212 45Degree pitch 7.5mm size 92.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-216_1x16_P7.50mm_45Degree +Terminal Block WAGO 236-216, 45Degree (cable under 45degree), 16 pins, pitch 7.5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-216 45Degree pitch 7.5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +16 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-224_1x24_P7.50mm_45Degree +Terminal Block WAGO 236-224, 45Degree (cable under 45degree), 24 pins, pitch 7.5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-224 45Degree pitch 7.5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +24 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-301_1x01_P10.00mm_45Degree +Terminal Block WAGO 236-301, 45Degree (cable under 45degree), 1 pins, pitch 10mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-301 45Degree pitch 10mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +1 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-302_1x02_P10.00mm_45Degree +Terminal Block WAGO 236-302, 45Degree (cable under 45degree), 2 pins, pitch 10mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-302 45Degree pitch 10mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-303_1x03_P10.00mm_45Degree +Terminal Block WAGO 236-303, 45Degree (cable under 45degree), 3 pins, pitch 10mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-303 45Degree pitch 10mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +3 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-304_1x04_P10.00mm_45Degree +Terminal Block WAGO 236-304, 45Degree (cable under 45degree), 4 pins, pitch 10mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-304 45Degree pitch 10mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-306_1x06_P10.00mm_45Degree +Terminal Block WAGO 236-306, 45Degree (cable under 45degree), 6 pins, pitch 10mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-306 45Degree pitch 10mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-308_1x08_P10.00mm_45Degree +Terminal Block WAGO 236-308, 45Degree (cable under 45degree), 8 pins, pitch 10mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-308 45Degree pitch 10mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-312_1x12_P10.00mm_45Degree +Terminal Block WAGO 236-312, 45Degree (cable under 45degree), 12 pins, pitch 10mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-312 45Degree pitch 10mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +12 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-316_1x16_P10.00mm_45Degree +Terminal Block WAGO 236-316, 45Degree (cable under 45degree), 16 pins, pitch 10mm, size 162x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-316 45Degree pitch 10mm size 162x14mm^2 drill 1.15mm pad 3mm +0 +16 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-324_1x24_P10.00mm_45Degree +Terminal Block WAGO 236-324, 45Degree (cable under 45degree), 24 pins, pitch 10mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-324 45Degree pitch 10mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +24 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-401_1x01_P5.00mm_45Degree +Terminal Block WAGO 236-401, 45Degree (cable under 45degree), 1 pins, pitch 5mm, size 7.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-401 45Degree pitch 5mm size 7.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-402_1x02_P5.00mm_45Degree +Terminal Block WAGO 236-402, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-402 45Degree pitch 5mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-403_1x03_P5.00mm_45Degree +Terminal Block WAGO 236-403, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-403 45Degree pitch 5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-404_1x04_P5.00mm_45Degree +Terminal Block WAGO 236-404, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-404 45Degree pitch 5mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-406_1x06_P5.00mm_45Degree +Terminal Block WAGO 236-406, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-406 45Degree pitch 5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-408_1x08_P5.00mm_45Degree +Terminal Block WAGO 236-408, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-408 45Degree pitch 5mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-412_1x12_P5.00mm_45Degree +Terminal Block WAGO 236-412, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-412 45Degree pitch 5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-416_1x16_P5.00mm_45Degree +Terminal Block WAGO 236-416, 45Degree (cable under 45degree), 16 pins, pitch 5mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-416 45Degree pitch 5mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-424_1x24_P5.00mm_45Degree +Terminal Block WAGO 236-424, 45Degree (cable under 45degree), 24 pins, pitch 5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-424 45Degree pitch 5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-436_1x36_P5.00mm_45Degree +Terminal Block WAGO 236-436, 45Degree (cable under 45degree), 36 pins, pitch 5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-436 45Degree pitch 5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +72 +36 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-448_1x48_P5.00mm_45Degree +Terminal Block WAGO 236-448, 45Degree (cable under 45degree), 48 pins, pitch 5mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-448 45Degree pitch 5mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +96 +48 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-501_1x01_P7.50mm_45Degree +Terminal Block WAGO 236-501, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 9.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-501 45Degree pitch 7.5mm size 9.8x14mm^2 drill 1.15mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-502_1x02_P7.50mm_45Degree +Terminal Block WAGO 236-502, 45Degree (cable under 45degree), 2 pins, pitch 7.5mm, size 17.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-502 45Degree pitch 7.5mm size 17.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-503_1x03_P7.50mm_45Degree +Terminal Block WAGO 236-503, 45Degree (cable under 45degree), 3 pins, pitch 7.5mm, size 24.8x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-503 45Degree pitch 7.5mm size 24.8x14mm^2 drill 1.15mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-504_1x04_P7.50mm_45Degree +Terminal Block WAGO 236-504, 45Degree (cable under 45degree), 4 pins, pitch 7.5mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-504 45Degree pitch 7.5mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-506_1x06_P7.50mm_45Degree +Terminal Block WAGO 236-506, 45Degree (cable under 45degree), 6 pins, pitch 7.5mm, size 47.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-506 45Degree pitch 7.5mm size 47.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-508_1x08_P7.50mm_45Degree +Terminal Block WAGO 236-508, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-508 45Degree pitch 7.5mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-512_1x12_P7.50mm_45Degree +Terminal Block WAGO 236-512, 45Degree (cable under 45degree), 12 pins, pitch 7.5mm, size 92.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-512 45Degree pitch 7.5mm size 92.3x14mm^2 drill 1.15mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-516_1x16_P7.50mm_45Degree +Terminal Block WAGO 236-516, 45Degree (cable under 45degree), 16 pins, pitch 7.5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-516 45Degree pitch 7.5mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-524_1x24_P7.50mm_45Degree +Terminal Block WAGO 236-524, 45Degree (cable under 45degree), 24 pins, pitch 7.5mm, size 182x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-524 45Degree pitch 7.5mm size 182x14mm^2 drill 1.15mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-601_1x01_P10.00mm_45Degree +Terminal Block WAGO 236-601, 45Degree (cable under 45degree), 1 pins, pitch 10mm, size 12.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-601 45Degree pitch 10mm size 12.3x14mm^2 drill 1.15mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-602_1x02_P10.00mm_45Degree +Terminal Block WAGO 236-602, 45Degree (cable under 45degree), 2 pins, pitch 10mm, size 22.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-602 45Degree pitch 10mm size 22.3x14mm^2 drill 1.15mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-603_1x03_P10.00mm_45Degree +Terminal Block WAGO 236-603, 45Degree (cable under 45degree), 3 pins, pitch 10mm, size 32.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-603 45Degree pitch 10mm size 32.3x14mm^2 drill 1.15mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-604_1x04_P10.00mm_45Degree +Terminal Block WAGO 236-604, 45Degree (cable under 45degree), 4 pins, pitch 10mm, size 42.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-604 45Degree pitch 10mm size 42.3x14mm^2 drill 1.15mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-606_1x06_P10.00mm_45Degree +Terminal Block WAGO 236-606, 45Degree (cable under 45degree), 6 pins, pitch 10mm, size 62.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-606 45Degree pitch 10mm size 62.3x14mm^2 drill 1.15mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-608_1x08_P10.00mm_45Degree +Terminal Block WAGO 236-608, 45Degree (cable under 45degree), 8 pins, pitch 10mm, size 82.3x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-608 45Degree pitch 10mm size 82.3x14mm^2 drill 1.15mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-612_1x12_P10.00mm_45Degree +Terminal Block WAGO 236-612, 45Degree (cable under 45degree), 12 pins, pitch 10mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-612 45Degree pitch 10mm size 122x14mm^2 drill 1.15mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-616_1x16_P10.00mm_45Degree +Terminal Block WAGO 236-616, 45Degree (cable under 45degree), 16 pins, pitch 10mm, size 162x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-616 45Degree pitch 10mm size 162x14mm^2 drill 1.15mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_236-624_1x24_P10.00mm_45Degree +Terminal Block WAGO 236-624, 45Degree (cable under 45degree), 24 pins, pitch 10mm, size 242x14mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 236-624 45Degree pitch 10mm size 242x14mm^2 drill 1.15mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-101_1x01_P5.00mm_45Degree +Terminal Block WAGO 804-101, 45Degree (cable under 45degree), 1 pins, pitch 5mm, size 6.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-101 45Degree pitch 5mm size 6.5x15mm^2 drill 1.2mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-102_1x02_P5.00mm_45Degree +Terminal Block WAGO 804-102, 45Degree (cable under 45degree), 2 pins, pitch 5mm, size 11.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-102 45Degree pitch 5mm size 11.5x15mm^2 drill 1.2mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-103_1x03_P5.00mm_45Degree +Terminal Block WAGO 804-103, 45Degree (cable under 45degree), 3 pins, pitch 5mm, size 16.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-103 45Degree pitch 5mm size 16.5x15mm^2 drill 1.2mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-104_1x04_P5.00mm_45Degree +Terminal Block WAGO 804-104, 45Degree (cable under 45degree), 4 pins, pitch 5mm, size 21.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-104 45Degree pitch 5mm size 21.5x15mm^2 drill 1.2mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-105_1x05_P5.00mm_45Degree +Terminal Block WAGO 804-105, 45Degree (cable under 45degree), 5 pins, pitch 5mm, size 26.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-105 45Degree pitch 5mm size 26.5x15mm^2 drill 1.2mm pad 3mm +0 +10 +5 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-106_1x06_P5.00mm_45Degree +Terminal Block WAGO 804-106, 45Degree (cable under 45degree), 6 pins, pitch 5mm, size 31.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-106 45Degree pitch 5mm size 31.5x15mm^2 drill 1.2mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-107_1x07_P5.00mm_45Degree +Terminal Block WAGO 804-107, 45Degree (cable under 45degree), 7 pins, pitch 5mm, size 36.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-107 45Degree pitch 5mm size 36.5x15mm^2 drill 1.2mm pad 3mm +0 +14 +7 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-108_1x08_P5.00mm_45Degree +Terminal Block WAGO 804-108, 45Degree (cable under 45degree), 8 pins, pitch 5mm, size 41.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-108 45Degree pitch 5mm size 41.5x15mm^2 drill 1.2mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-109_1x09_P5.00mm_45Degree +Terminal Block WAGO 804-109, 45Degree (cable under 45degree), 9 pins, pitch 5mm, size 46.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-109 45Degree pitch 5mm size 46.5x15mm^2 drill 1.2mm pad 3mm +0 +18 +9 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-110_1x10_P5.00mm_45Degree +Terminal Block WAGO 804-110, 45Degree (cable under 45degree), 10 pins, pitch 5mm, size 51.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-110 45Degree pitch 5mm size 51.5x15mm^2 drill 1.2mm pad 3mm +0 +20 +10 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-112_1x12_P5.00mm_45Degree +Terminal Block WAGO 804-112, 45Degree (cable under 45degree), 12 pins, pitch 5mm, size 61.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-112 45Degree pitch 5mm size 61.5x15mm^2 drill 1.2mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-116_1x16_P5.00mm_45Degree +Terminal Block WAGO 804-116, 45Degree (cable under 45degree), 16 pins, pitch 5mm, size 81.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-116 45Degree pitch 5mm size 81.5x15mm^2 drill 1.2mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-124_1x24_P5.00mm_45Degree +Terminal Block WAGO 804-124, 45Degree (cable under 45degree), 24 pins, pitch 5mm, size 122x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-124 45Degree pitch 5mm size 122x15mm^2 drill 1.2mm pad 3mm +0 +48 +24 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-301_1x01_P7.50mm_45Degree +Terminal Block WAGO 804-301, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 6.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-301 45Degree pitch 7.5mm size 6.5x15mm^2 drill 1.2mm pad 3mm +0 +2 +1 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-302_1x02_P7.50mm_45Degree +Terminal Block WAGO 804-302, 45Degree (cable under 45degree), 2 pins, pitch 7.5mm, size 14x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-302 45Degree pitch 7.5mm size 14x15mm^2 drill 1.2mm pad 3mm +0 +4 +2 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-303_1x03_P7.50mm_45Degree +Terminal Block WAGO 804-303, 45Degree (cable under 45degree), 3 pins, pitch 7.5mm, size 21.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-303 45Degree pitch 7.5mm size 21.5x15mm^2 drill 1.2mm pad 3mm +0 +6 +3 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-304_1x04_P7.50mm_45Degree +Terminal Block WAGO 804-304, 45Degree (cable under 45degree), 4 pins, pitch 7.5mm, size 29x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-304 45Degree pitch 7.5mm size 29x15mm^2 drill 1.2mm pad 3mm +0 +8 +4 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-305_1x05_P7.50mm_45Degree +Terminal Block WAGO 804-305, 45Degree (cable under 45degree), 5 pins, pitch 7.5mm, size 36.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-305 45Degree pitch 7.5mm size 36.5x15mm^2 drill 1.2mm pad 3mm +0 +10 +5 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-306_1x06_P7.50mm_45Degree +Terminal Block WAGO 804-306, 45Degree (cable under 45degree), 6 pins, pitch 7.5mm, size 44x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-306 45Degree pitch 7.5mm size 44x15mm^2 drill 1.2mm pad 3mm +0 +12 +6 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-307_1x07_P7.50mm_45Degree +Terminal Block WAGO 804-307, 45Degree (cable under 45degree), 7 pins, pitch 7.5mm, size 51.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-307 45Degree pitch 7.5mm size 51.5x15mm^2 drill 1.2mm pad 3mm +0 +14 +7 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-308_1x08_P7.50mm_45Degree +Terminal Block WAGO 804-308, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 59x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-308 45Degree pitch 7.5mm size 59x15mm^2 drill 1.2mm pad 3mm +0 +16 +8 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-309_1x09_P7.50mm_45Degree +Terminal Block WAGO 804-309, 45Degree (cable under 45degree), 9 pins, pitch 7.5mm, size 66.5x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-309 45Degree pitch 7.5mm size 66.5x15mm^2 drill 1.2mm pad 3mm +0 +18 +9 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-310_1x10_P7.50mm_45Degree +Terminal Block WAGO 804-310, 45Degree (cable under 45degree), 10 pins, pitch 7.5mm, size 74x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-310 45Degree pitch 7.5mm size 74x15mm^2 drill 1.2mm pad 3mm +0 +20 +10 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-312_1x12_P7.50mm_45Degree +Terminal Block WAGO 804-312, 45Degree (cable under 45degree), 12 pins, pitch 7.5mm, size 89x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-312 45Degree pitch 7.5mm size 89x15mm^2 drill 1.2mm pad 3mm +0 +24 +12 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-316_1x16_P7.50mm_45Degree +Terminal Block WAGO 804-316, 45Degree (cable under 45degree), 16 pins, pitch 7.5mm, size 119x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-316 45Degree pitch 7.5mm size 119x15mm^2 drill 1.2mm pad 3mm +0 +32 +16 +TerminalBlock_WAGO +TerminalBlock_WAGO_804-324_1x24_P7.50mm_45Degree +Terminal Block WAGO 804-324, 45Degree (cable under 45degree), 24 pins, pitch 7.5mm, size 179x15mm^2, drill diamater 1.2mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO +THT Terminal Block WAGO 804-324 45Degree pitch 7.5mm size 179x15mm^2 drill 1.2mm pad 3mm +0 +48 +24 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650073_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650073.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650074_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650074.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650094_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650094.pdf) +screw terminal thread redcube thr power connector +0 +16 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650173_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650173.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650174_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650174.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650194_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650194.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74650195_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74650195.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRBU_74655095_THR +REDCUBE THR with internal through-hole thread WP-THRBU (https://www.we-online.de/katalog/datasheet/74655095.pdf) +screw terminal thread redcube thr power connector +0 +16 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651173_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651173.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651174_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651174.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651175_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651175.pdf) +screw terminal thread redcube thr power connector +0 +8 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651194_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651194.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TerminalBlock_Wuerth +Wuerth_REDCUBE-THR_WP-THRSH_74651195_THR +REDCUBE THR with internal through-hole thread WP-THRSH (https://www.we-online.de/katalog/datasheet/74651195.pdf) +screw terminal thread redcube thr power connector +0 +18 +1 +TestPoint +TestPoint_2Pads_Pitch2.54mm_Drill0.8mm +Test point with 2 pins, pitch 2.54mm, drill diameter 0.8mm +CONN DEV +0 +2 +2 +TestPoint +TestPoint_2Pads_Pitch5.08mm_Drill1.3mm +Test point with 2 pads, pitch 5.08mm, hole diameter 1.3mm, wire diameter 1.0mm +CONN DEV +0 +2 +2 +TestPoint +TestPoint_Bridge_Pitch2.0mm_Drill0.7mm +wire loop as test point, pitch 2.0mm, hole diameter 0.7mm, wire diameter 0.5mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch2.54mm_Drill0.7mm +wire loop as test point, pitch 2.0mm, hole diameter 0.7mm, wire diameter 0.5mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch2.54mm_Drill1.0mm +wire loop as test point, pitch 2.54mm, hole diameter 1.0mm, wire diameter 0.8mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch2.54mm_Drill1.3mm +wire loop as test point, pitch 2.54mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch3.81mm_Drill1.3mm +wire loop as test point, pitch 3.81mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch5.08mm_Drill0.7mm +wire loop as test point, pitch 5.08mm, hole diameter 0.7mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch5.08mm_Drill1.3mm +wire loop as test point, pitch 5.08mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch6.35mm_Drill1.3mm +wire loop as test point, pitch 6.35mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Bridge_Pitch7.62mm_Drill1.3mm +wire loop as test point, pitch 7.62mm, hole diameter 1.3mm, wire diameter 1.0mm +test point wire loop +0 +2 +1 +TestPoint +TestPoint_Keystone_5000-5004_Miniature +Keystone Miniature THM Test Point 5000-5004, http://www.keyelco.com/product-pdf.cfm?p=1309 +Through Hole Mount Test Points +0 +1 +1 +TestPoint +TestPoint_Keystone_5005-5009_Compact +Keystone Miniature THM Test Point 5005-5009, http://www.keyelco.com/product-pdf.cfm?p=1314 +Through Hole Mount Test Points +0 +1 +1 +TestPoint +TestPoint_Keystone_5010-5014_Multipurpose +Keystone Miniature THM Test Point 5010-5014, http://www.keyelco.com/product-pdf.cfm?p=1319 +Through Hole Mount Test Points +0 +1 +1 +TestPoint +TestPoint_Keystone_5015_Micro-Minature +SMT Test Point- Micro Miniature 5015, http://www.keyelco.com/product-pdf.cfm?p=1353 +Test Point +0 +1 +1 +TestPoint +TestPoint_Keystone_5019_Minature +SMT Test Point- Micro Miniature 5019, http://www.keyelco.com/product-pdf.cfm?p=1357 +Test Point +0 +1 +1 +TestPoint +TestPoint_Loop_D1.80mm_Drill1.0mm_Beaded +wire loop with bead as test point, loop diameter 1.8mm, hole diameter 1.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.50mm_Drill1.0mm +wire loop as test point, loop diameter 2.5mm, hole diameter 1.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.50mm_Drill1.0mm_LowProfile +low profile wire loop as test point, loop diameter 2.5mm, hole diameter 1.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.50mm_Drill1.85mm +wire loop as test point, loop diameter 2.5mm, hole diameter 1.85mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.54mm_Drill1.5mm_Beaded +wire loop with bead as test point, loop diameter2.548mm, hole diameter 1.5mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.60mm_Drill0.9mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 0.9mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.60mm_Drill1.4mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 1.4mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D2.60mm_Drill1.6mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 1.6mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.50mm_Drill0.9mm_Beaded +wire loop with bead as test point, loop diameter2.6mm, hole diameter 0.9mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.50mm_Drill1.4mm_Beaded +wire loop with bead as test point, loop diameter 3.5mm, hole diameter 1.4mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.80mm_Drill2.0mm +wire loop as test point, loop diameter 3.8mm, hole diameter 2.0mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.80mm_Drill2.5mm +wire loop as test point, loop diameter 3.8mm, hole diameter 2.5mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Loop_D3.80mm_Drill2.8mm +wire loop as test point, loop diameter 3.8mm, hole diameter 2.8mm +test point wire loop bead +0 +1 +1 +TestPoint +TestPoint_Pad_1.0x1.0mm +SMD rectangular pad as test Point, square 1.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_1.5x1.5mm +SMD rectangular pad as test Point, square 1.5mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_2.0x2.0mm +SMD rectangular pad as test Point, square 2.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_2.5x2.5mm +SMD rectangular pad as test Point, square 2.5mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_3.0x3.0mm +SMD rectangular pad as test Point, square 3.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_4.0x4.0mm +SMD rectangular pad as test Point, square 4.0mm side length +test point SMD pad rectangle square +0 +1 +1 +TestPoint +TestPoint_Pad_D1.0mm +SMD pad as test Point, diameter 1.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D1.5mm +SMD pad as test Point, diameter 1.5mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D2.0mm +SMD pad as test Point, diameter 2.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D2.5mm +SMD pad as test Point, diameter 2.5mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D3.0mm +SMD pad as test Point, diameter 3.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Pad_D4.0mm +SMD pad as test Point, diameter 4.0mm +test point SMD pad +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D2.0mm +Plated Hole as test Point, diameter 2.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D3.0mm +Plated Hole as test Point, diameter 3.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D4.0mm +Plated Hole as test Point, diameter 4.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_Plated_Hole_D5.0mm +Plated Hole as test Point, diameter 5.0mm +test point plated hole +0 +1 +1 +TestPoint +TestPoint_THTPad_1.0x1.0mm_Drill0.5mm +THT rectangular pad as test Point, square 1.0mm side length, hole diameter 0.5mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_1.5x1.5mm_Drill0.7mm +THT rectangular pad as test Point, square 1.5mm side length, hole diameter 0.7mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_2.0x2.0mm_Drill1.0mm +THT rectangular pad as test Point, square 2.0mm_Drill1.0mm side length, hole diameter 1.0mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_2.5x2.5mm_Drill1.2mm +THT rectangular pad as test Point, square 2.5mm side length, hole diameter 1.2mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_3.0x3.0mm_Drill1.5mm +THT rectangular pad as test Point, square 3.0mm side length, hole diameter 1.5mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_4.0x4.0mm_Drill2.0mm +THT rectangular pad as test Point, square 4.0mm side length, hole diameter 2.0mm +test point THT pad rectangle square +0 +1 +1 +TestPoint +TestPoint_THTPad_D1.0mm_Drill0.5mm +THT pad as test Point, diameter 1.0mm, hole diameter 0.5mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D1.5mm_Drill0.7mm +THT pad as test Point, diameter 1.5mm, hole diameter 0.7mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D2.0mm_Drill1.0mm +THT pad as test Point, diameter 2.0mm, hole diameter 1.0mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D2.5mm_Drill1.2mm +THT pad as test Point, diameter 2.5mm, hole diameter 1.2mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D3.0mm_Drill1.5mm +THT pad as test Point, diameter 3.0mm, hole diameter 1.5mm +test point THT pad +0 +1 +1 +TestPoint +TestPoint_THTPad_D4.0mm_Drill2.0mm +THT pad as test Point, diameter 4.0mm, hole diameter 2.0mm +test point THT pad +0 +1 +1 +Transformer_SMD +Pulse_P0926NL +SMT Gate Drive Transformer, 1:1:1, 8.0x6.3x5.3mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa0926nl +0 +6 +6 +Transformer_SMD +Pulse_PA1323NL +SMT Gate Drive Transformer, 1:1, 9.5x7.1x5.3mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa1323nl +0 +6 +6 +Transformer_SMD +Pulse_PA2001NL +SMT Gate Drive Transformer, 1:1, 8.6x6.7x2.5mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2001nl pe-68386nl +0 +4 +4 +Transformer_SMD +Pulse_PA2002NL-PA2008NL-PA2009NL +SMT Gate Drive Transformer, 1:1:1 or 2:1:1 or 2.5:1:1 or 1:1, 9.0x8.6x7.6mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2002nl pa2008nl pa2009nl p0544nl pa0184nl pa0297nl pa0510nl +0 +6 +6 +Transformer_SMD +Pulse_PA2004NL +SMT Gate Drive Transformer, 1:1:1, 8.6x6.7x3.6mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2004nl pa0264nl +0 +6 +6 +Transformer_SMD +Pulse_PA2005NL +SMT Gate Drive Transformer, 1:1:1, 11.8x8.8x4.0mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2005nl pa0173nl +0 +6 +6 +Transformer_SMD +Pulse_PA2006NL +SMT Gate Drive Transformer, 1:1, 11.8x8.8x4.0mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2006nl pa0186nl +0 +4 +4 +Transformer_SMD +Pulse_PA2007NL +SMT Gate Drive Transformer, 1:1, 9.0x8.6x7.6mm (https://productfinder.pulseeng.com/products/datasheets/P663.pdf) +pulse pa2007nl +0 +4 +4 +Transformer_SMD +Pulse_PA2777NL +SMT Gate Drive Transformer, 1:1, 7.1x6.1x5.5mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa2777nl +0 +8 +8 +Transformer_SMD +Pulse_PA3493NL +SMT Gate Drive Transformer, 1.25:1, 10.9x9.7x2.7mm (https://productfinder.pulseeng.com/products/datasheets/SPM2007_61.pdf) +pulse pa3493nl +0 +4 +4 +Transformer_SMD +Transformer_Coilcraft_CST1 +Current sense transformer, SMD, 8.0x8.13x5.3mm (https://www.coilcraft.com/pdfs/cst.pdf) +Transformer current sense SMD +0 +8 +8 +Transformer_SMD +Transformer_Coilcraft_CST2 +Current sense transformer, SMD, 8.0x8.13x5.3mm (https://www.coilcraft.com/pdfs/cst.pdf) +Transformer current sense SMD +0 +8 +8 +Transformer_SMD +Transformer_Coilcraft_CST2010 +Current sense transformer, SMD, 14.55x19.91x10.50mm (https://www.coilcraft.com/pdfs/cst2010.pdf) +Transformer current sense SMD +0 +12 +12 +Transformer_SMD +Transformer_CurrentSense_8.4x7.2mm +Transformer current sense SMD 8.4x7.2mm +Transformer current sense SMD +0 +8 +8 +Transformer_SMD +Transformer_Ethernet_Bel_S558-5999-T7-F +Ethernet Transformer, Bel S558-5999-T7-F, https://www.belfuse.com/resources/ICMs/lan-/S558-5999-T7-F.pdf +Ethernet Transformer +0 +16 +16 +Transformer_SMD +Transformer_Ethernet_Bourns_PT61017PEL +https://www.bourns.com/docs/Product-Datasheets/PT61017PEL.pdf +Transformer Ethernet Single Center-Tap +0 +16 +16 +Transformer_SMD +Transformer_Ethernet_HALO_TG111-MSC13 +Transformer Ethernet SMD, https://www.haloelectronics.com/pdf/discrete-genesus.pdf +Transformer Ethernet SMD +0 +24 +24 +Transformer_SMD +Transformer_MACOM_SM-22 +https://cdn.macom.com/datasheets/ETC1-1-13.pdf +RF Transformer +0 +5 +5 +Transformer_SMD +Transformer_Murata_78250JC +Murata 78250JC https://www.murata-ps.com/datasheet?/data/magnetics/kmp_78250j.pdf +Murata transformer +0 +6 +6 +Transformer_SMD +Transformer_NF_ETAL_P2781 +NF-Transformer, ETAL, P2781, SMD, +NF-Transformer ETAL P2781 SMD +0 +8 +7 +Transformer_SMD +Transformer_NF_ETAL_P2781_HandSoldering +NF-Transformer, ETAL, P2781, SMD, Handsoldering +NF-Transformer ETAL P2781 SMD Handsoldering +0 +8 +7 +Transformer_SMD +Transformer_NF_ETAL_P3000 +NF-Reansformer, ETAL, P3000, SMD, +NF-Reansformer ETAL P3000 SMD +0 +15 +13 +Transformer_SMD +Transformer_NF_ETAL_P3000_HandSoldering +NF-Reansformer, ETAL, P3000, SMD, Handsoldering, +NF-Reansformer ETAL P3000 SMD Handsoldering +0 +15 +13 +Transformer_SMD +Transformer_NF_ETAL_P3181 +NF-Transformer, ETAL, P3181, SMD, +NF-Transformer ETAL P3181 SMD +0 +7 +6 +Transformer_SMD +Transformer_NF_ETAL_P3181_HandSoldering +NF-Transformer, ETAL, P3181, SMD, Hand Soldering, +NF-Transformer ETAL P3181 SMD Hand Soldering +0 +7 +6 +Transformer_SMD +Transformer_NF_ETAL_P3188 +NF-Transformer, ETAL, P3188, SMD, +NF-Transformer ETAL P3188 SMD +0 +8 +6 +Transformer_SMD +Transformer_NF_ETAL_P3188_HandSoldering +NF-Transformer, ETAL, P3188, SMD, Handsoldering, +NF-Transformer ETAL P3188 SMD Handsoldering +0 +8 +6 +Transformer_SMD +Transformer_NF_ETAL_P3191 +NF-Transformer, ETAL, P3191, SMD, +NF-Transformer ETAL P3191 SMD +0 +8 +6 +Transformer_SMD +Transformer_NF_ETAL_P3191_HandSoldering +NF-Transformer, ETAL, P3191, SMD, Handsoldering, +NF-Transformer ETAL P3191 SMD Handsoldering +0 +8 +6 +Transformer_SMD +Transformer_Pulse_H1100NL +For H1100NL, H1101NL, H1102NL, H1121NL, H1183NL, H1199NL, HX1188NL, HX1198NL and H1302NL. https://productfinder.pulseeng.com/doc_type/WEB301/doc_num/H1102NL/doc_part/H1102NL.pdf +H1100NL H1101NL H1102NL H1121NL H1183NL H1199NL HX1188NL HX1198NL H1302N +0 +16 +16 +Transformer_SMD +Transformer_Wuerth_750315371 +Power Transformer, horizontal core with bobbin, 6 pin, 2.54mm pitch, 11.24mm row spacing, 12.6x8.3x4.1mm +transformer flyback +0 +6 +6 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D9.0mm_Amidon-T30 +Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 9mm, Amidon T30, +Autotransformer Toroid horizontal laying 1 Tap Diameter 9mm Amidon T30 +0 +3 +3 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D10.5mm_Amidon-T37 +Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 10,5mm, Amidon T37, +Autotransformer Toroid horizontal laying 1 Tap Diameter 10 5mm Amidon T37 +0 +3 +3 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D12.5mm_Amidon-T44 +Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 12,5mm, Amidon T44, +Autotransformer Toroid horizontal laying 1 Tap Diameter 12 5mm Amidon T44 +0 +3 +3 +Transformer_THT +Autotransformer_Toroid_1Tap_Horizontal_D14.0mm_Amidon-T50 +Choke, Inductance, Autotransformer, Toroid, horizontal, laying, 1 Tap, Diameter 14mm, Amidon T50, +Choke Inductance Autotransformer Toroid horizontal laying 1 Tap Diameter 14mm Amidon T50 +0 +3 +3 +Transformer_THT +Autotransformer_ZS1052-AC +Ignition coil for xenon flash, http://www.excelitas.com/downloads/ZS1052ACH.pdf +ignition coil autotransformer +0 +3 +3 +Transformer_THT +Transformer_37x44 +transformer 37x44mm² +transformer 37x44mm² +0 +12 +4 +Transformer_THT +Transformer_Breve_TEZ-22x24 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +7 +7 +Transformer_THT +Transformer_Breve_TEZ-28x33 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +9 +9 +Transformer_THT +Transformer_Breve_TEZ-35x42 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +9 +9 +Transformer_THT +Transformer_Breve_TEZ-38x45 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +9 +9 +Transformer_THT +Transformer_Breve_TEZ-44x52 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +10 +10 +Transformer_THT +Transformer_Breve_TEZ-47x57 +http://www.breve.pl/pdf/ANG/TEZ_ang.pdf +TEZ PCB Transformer +0 +13 +13 +Transformer_THT +Transformer_CHK_EI30-2VA_1xSec +Trafo, Printtrafo, CHK, EI30, 2VA, 1x Sec,http://www.eratransformers.com/downloads/030-7585.0.pdf +Trafo Printtrafo CHK EI30 2VA 1x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI30-2VA_2xSec +Trafo, Printtrafo, CHK, EI30, 2VA, 2x Sec, +Trafo Printtrafo CHK EI30 2VA 2x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI30-2VA_Neutral +Trafo, Printtrafo, CHK, EI30, 2VA, neutral, +Trafo Printtrafo CHK EI30 2VA neutral +0 +10 +10 +Transformer_THT +Transformer_CHK_EI38-3VA_1xSec +Trafo, Printtrafo, CHK, EI38, 3VA, 1x Sec, http://www.eratransformers.com/product-detail/20 +Trafo Printtrafo CHK EI38 3VA 1x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI38-3VA_2xSec +Trafo, Printtrafo, CHK, EI38, 3VA, 2x Sec, http://www.eratransformers.com/product-detail/20 +Trafo Printtrafo CHK EI38 3VA 2x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI38-3VA_Neutral +Trafo, Printtrafo, CHK, EI38, 3VA, neutral, http://www.eratransformers.com/product-detail/20 +Trafo Printtrafo CHK EI42 3VA neutral +0 +10 +10 +Transformer_THT +Transformer_CHK_EI42-5VA_1xSec +Trafo, Printtrafo, CHK, EI42, 5VA, 1x Sec, +Trafo Printtrafo CHK EI42 5VA 1x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI42-5VA_2xSec +Trafo, Printtrafo, CHK, EI42, 5VA, 2x Sec, +Trafo Printtrafo CHK EI42 5VA 2x Sec +0 +10 +10 +Transformer_THT +Transformer_CHK_EI42-5VA_Neutral +Trafo, Printtrafo, CHK, EI42, 5VA, neutral, +Trafo Printtrafo CHK EI42 5VA neutral +0 +10 +10 +Transformer_THT +Transformer_CHK_EI48-8VA_1xSec +Trafo, Printtrafo, CHK, EI48, 8VA, 1x Sec, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 8VA 1x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-8VA_2xSec +Trafo, Printtrafo, CHK, EI48, 8VA, 2x Sec, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 8VA 2x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-8VA_Neutral +Trafo, Printtrafo, CHK, EI48, 8VA, neutral, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 8VA neutral +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-10VA_1xSec +Trafo, Printtrafo, CHK, EI48, 10VA, 1x Sec, +Trafo Printtrafo CHK EI48 10VA 1x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-10VA_2xSec +Trafo, Printtrafo, CHK, EI48, 10VA, 2x Sec, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 10VA 2x Sec +0 +12 +12 +Transformer_THT +Transformer_CHK_EI48-10VA_Neutral +Trafo, Printtrafo, CHK, EI48, 10VA, neutral, http://www.eratransformers.com/product-detail/18 +Trafo Printtrafo CHK EI48 10VA neutral +0 +12 +12 +Transformer_THT +Transformer_CHK_EI54-12VA_1xSec +Trafo, Printtrafo, CHK, EI54, 12VA, 1x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 12VA 1x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-12VA_2xSec +Trafo, Printtrafo, CHK, EI54, 12VA, 2x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 12VA 2x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-12VA_Neutral +Trafo, Printtrafo, CHK, EI54, 12VA, neutral,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 12VA neutral +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-16VA_1xSec +Trafo, Printtrafo, CHK, EI54, 16VA, 1x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 16VA 1x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-16VA_2xSec +Trafo, Printtrafo, CHK, EI54, 16VA, 2x Sec,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 16VA 2x Sec +0 +14 +14 +Transformer_THT +Transformer_CHK_EI54-16VA_Neutral +Trafo, Printtrafo, CHK, EI54, 16VA, neutral,http://www.eratransformers.com/product-detail/19 +Trafo Printtrafo CHK EI54 16VA neutral +0 +14 +14 +Transformer_THT +Transformer_CHK_UI30-4VA_Flat +Trafo, Flattrafo, CHK, UI30, 4VA, +Trafo Flattrafo CHK UI30 4VA +0 +16 +16 +Transformer_THT +Transformer_CHK_UI39-10VA_Flat +Trafo, Flattrafo, CHK, UI39, 10VA, +Trafo Flattrafo CHK UI39 10VA +0 +20 +20 +Transformer_THT +Transformer_Coilcraft_Q4434-B_Rhombus-T1311 +Transformator, Transformer, Flyback, Coilcraft Q4434-B, Rgombus T1311, +Transformator Transformer Flyback Coilcraft Q4434-B Rgombus T1311 +0 +8 +8 +Transformer_THT +Transformer_EPCOS_B66359A1013T_Horizontal +Transformer, Transformator, ETD29, 13 Pin, Horizontal, EPCOS-B66359A1013T, +Transformer Transformator ETD29 13 Pin Horizontal EPCOS-B66359A1013T +0 +13 +13 +Transformer_THT +Transformer_EPCOS_B66359J1014T_Vertical +Transformer, Transformator, ETD29, 14 Pin, Vertical, EPCOS-B66359J1014T, +Transformer Transformator ETD29 14 Pin Vertical EPCOS-B66359J1014T +0 +14 +14 +Transformer_THT +Transformer_Microphone_Lundahl_LL1538 +AUDIO TRAFO LUNDAHL, https://www.lundahltransformers.com/wp-content/uploads/datasheets/1538_8xl.pdf +AUDIO TRAFO LUNDAHL +0 +7 +7 +Transformer_THT +Transformer_Microphone_Lundahl_LL1587 +AUDIO TRAFO LUNDAHL, https://www.lundahltransformers.com/wp-content/uploads/datasheets/1587.pdf +AUDIO TRAFO LUNDAHL +0 +7 +7 +Transformer_THT +Transformer_Myrra_74040_Horizontal +Transformer, Transformator, ETD29, 13 Pin, Horizontal, Myrra-74040, +Transformer Transformator ETD29 13 Pin Horizontal Myrra-74040 +0 +13 +13 +Transformer_THT +Transformer_Myrra_EF20_7408x +EF20 flyback transformer,http://myrra.com/wp-content/uploads/2017/09/Datasheet-74087-74088-74089-rev-A.pdf +transformer flyback SMPS +0 +9 +9 +Transformer_THT +Transformer_NF_ETAL_1-1_P1200 +NF-Transformer, 1:1, ETAL P1200,http://www.etalgroup.com/sites/default/files/products/P1200_April_2005.pdf +NF-Transformer 1to1 ETAL P1200 +0 +4 +4 +Transformer_THT +Transformer_NF_ETAL_P1165 +NF-Transformer, ETAL, P1165,http://www.etalgroup.com/sites/default/files/products/P1165_February_2006.pdf +NF-Transformer ETAL P1165 +0 +4 +4 +Transformer_THT +Transformer_NF_ETAL_P3324 +NF-Transformer, ETAL P3324,http://www.etalgroup.com/sites/default/files/products/P3324_April_2005.pdf +NF-Transformer ETAL P3324 +0 +4 +4 +Transformer_THT +Transformer_NF_ETAL_P3356 +NF-Transformer, ETAL P3356, http://www.etalgroup.com/sites/default/files/products/P3356_December_2005.pdf +NF-Transformer ETAL P3356 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D9.0mm_Amidon-T30 +Transformer, Toroid, horizontal, laying, Diameter 9mm, Amidon, T30, +Transformer Toroid horizontal laying Diameter 9mm Amidon T30 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D10.5mm_Amidon-T37 +Transformer, Toroid, horizontal, laying, Diameter 10,5mm, Amidon T37, +Transformer Toroid horizontal laying Diameter 10 5mm Amidon T37 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D12.5mm_Amidon-T44 +Transformer, Toroid, horizontal, laying, Diameter 12,5mm, Amidon T44, +Transformer Toroid horizontal laying Diameter 12 5mm Amidon T44 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D14.0mm_Amidon-T50 +Transformer, Toroid, horizontal, laying, Diameter 14mm, Amidon T50, +Transformer Toroid horizontal laying Diameter 14mm Amidon T50 +0 +4 +4 +Transformer_THT +Transformer_Toroid_Horizontal_D18.0mm +Transformer, Toroid, tapped, horizontal, laying, Diameter 18mm, +Transformer Toroid tapped horizontal laying Diameter 18mm +0 +5 +4 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D9.0mm_Amidon-T30 +Transformer, Toroid, tapped, horizontal, laying, Diameter 9mm, Amidon, T30, +Transformer Toroid tapped horizontal laying Diameter 9mm Amidon T30 +0 +6 +6 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D10.5mm_Amidon-T37 +Transformer, Toroid, tapped, horizontal, laying, Diameter 10,5mm, Amidon, T37, +Transformer Toroid tapped horizontal laying Diameter 10 5mm Amidon T37 +0 +6 +6 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D12.5mm_Amidon-T44 +Transformer, Toroid, tapped, horizontal, laying, Diameter 12,5mm, Amidon, T44, +Transformer Toroid tapped horizontal laying Diameter 12 5mm Amidon T44 +0 +6 +6 +Transformer_THT +Transformer_Toroid_Tapped_Horizontal_D14.0mm_Amidon-T50 +Transformer, Toroid, tapped, horizontal, laying, Diameter 14mm, Amidon T50, +Transformer Toroid tapped horizontal laying Diameter 14mm Amidon T50 +0 +6 +6 +Transformer_THT +Transformer_Wuerth_750343373 +Transformer, horizontal core with bobbin, 10 pin, 3.81mm pitch, 15.24mm row spacing, 22x23x17.53mm (https://katalog.we-online.com/ctm/datasheet/750343373.pdf) +transformer flyback +0 +10 +10 +Valve +Valve_ECC-83-1 +Valve ECC-83-1 round pins +Valve ECC-83-1 round pins +0 +9 +9 +Valve +Valve_ECC-83-2 +Valve ECC-83-2 flat pins +Valve ECC-83-2 flat pins +0 +10 +9 +Valve +Valve_EURO +Valve Euro +Valve Euro +0 +7 +5 +Valve +Valve_Glimm +Valve Glimm +Valve Glimm +0 +2 +2 +Valve +Valve_Mini_G +Valve mini G +Valve mini G +0 +9 +7 +Valve +Valve_Mini_P +Valve mini P +Valve mini P +0 +7 +7 +Valve +Valve_Mini_Pentode_Linear +Mini-Pentode, 5-pin, e.g. JAN6418 +Valve Mini-Pentode 5-pin JAN6418 +0 +5 +5 +Valve +Valve_Noval_G +Valve NOVAL G +Valve NOVAL G +0 +11 +9 +Valve +Valve_Noval_P +Valve NOVAL P +Valve NOVAL P +0 +9 +9 +Valve +Valve_Octal +8-pin round valve +valve +0 +9 +8 +Varistor +RV_Disc_D7mm_W3.4mm_P5mm +Varistor, diameter 7mm, width 3.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.5mm_P5mm +Varistor, diameter 7mm, width 3.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.6mm_P5mm +Varistor, diameter 7mm, width 3.6mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.7mm_P5mm +Varistor, diameter 7mm, width 3.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.8mm_P5mm +Varistor, diameter 7mm, width 3.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W3.9mm_P5mm +Varistor, diameter 7mm, width 3.9mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.2mm_P5mm +Varistor, diameter 7mm, width 4.2mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.3mm_P5mm +Varistor, diameter 7mm, width 4.3mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.5mm_P5mm +Varistor, diameter 7mm, width 4.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.8mm_P5mm +Varistor, diameter 7mm, width 4.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4.9mm_P5mm +Varistor, diameter 7mm, width 4.9mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W4mm_P5mm +Varistor, diameter 7mm, width 4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.1mm_P5mm +Varistor, diameter 7mm, width 5.1mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.4mm_P5mm +Varistor, diameter 7mm, width 5.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.5mm_P5mm +Varistor, diameter 7mm, width 5.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D7mm_W5.7mm_P5mm +Varistor, diameter 7mm, width 5.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.3mm_P5mm +Varistor, diameter 9mm, width 3.3mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.4mm_P5mm +Varistor, diameter 9mm, width 3.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.5mm_P5mm +Varistor, diameter 9mm, width 3.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.6mm_P5mm +Varistor, diameter 9mm, width 3.6mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.7mm_P5mm +Varistor, diameter 9mm, width 3.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.8mm_P5mm +Varistor, diameter 9mm, width 3.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W3.9mm_P5mm +Varistor, diameter 9mm, width 3.9mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.1mm_P5mm +Varistor, diameter 9mm, width 4.1mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.2mm_P5mm +Varistor, diameter 9mm, width 4.2mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.4mm_P5mm +Varistor, diameter 9mm, width 4.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.5mm_P5mm +Varistor, diameter 9mm, width 4.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4.8mm_P5mm +Varistor, diameter 9mm, width 4.8mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W4mm_P5mm +Varistor, diameter 9mm, width 4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.2mm_P5mm +Varistor, diameter 9mm, width 5.2mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.4mm_P5mm +Varistor, diameter 9mm, width 5.4mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.5mm_P5mm +Varistor, diameter 9mm, width 5.5mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W5.7mm_P5mm +Varistor, diameter 9mm, width 5.7mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D9mm_W6.1mm_P5mm +Varistor, diameter 9mm, width 6.1mm, pitch 5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W3.9mm_P7.5mm +Varistor, diameter 12mm, width 3.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.2mm_P7.5mm +Varistor, diameter 12mm, width 4.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.3mm_P7.5mm +Varistor, diameter 12mm, width 4.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.4mm_P7.5mm +Varistor, diameter 12mm, width 4.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.5mm_P7.5mm +Varistor, diameter 12mm, width 4.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.6mm_P7.5mm +Varistor, diameter 12mm, width 4.6mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.7mm_P7.5mm +Varistor, diameter 12mm, width 4.7mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4.8mm_P7.5mm +Varistor, diameter 12mm, width 4.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W4mm_P7.5mm +Varistor, diameter 12mm, width 4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5.1mm_P7.5mm +Varistor, diameter 12mm, width 5.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5.4mm_P7.5mm +Varistor, diameter 12mm, width 5.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5.8mm_P7.5mm +Varistor, diameter 12mm, width 5.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W5mm_P7.5mm +Varistor, diameter 12mm, width 5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.1mm_P7.5mm +Varistor, diameter 12mm, width 6.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.2mm_P7.5mm +Varistor, diameter 12mm, width 6.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.3mm_P7.5mm +Varistor, diameter 12mm, width 6.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W6.7mm_P7.5mm +Varistor, diameter 12mm, width 6.7mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W7.1mm_P7.5mm +Varistor, diameter 12mm, width 7.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W7.5mm_P7.5mm +Varistor, diameter 12mm, width 7.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D12mm_W7.9mm_P7.5mm +Varistor, diameter 12mm, width 7.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W3.9mm_P7.5mm +Varistor, diameter 15.5mm, width 3.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.2mm_P7.5mm +Varistor, diameter 15.5mm, width 4.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.3mm_P7.5mm +Varistor, diameter 15.5mm, width 4.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.4mm_P7.5mm +Varistor, diameter 15.5mm, width 4.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.5mm_P7.5mm +Varistor, diameter 15.5mm, width 4.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.6mm_P7.5mm +Varistor, diameter 15.5mm, width 4.6mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.7mm_P7.5mm +Varistor, diameter 15.5mm, width 4.7mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.8mm_P7.5mm +Varistor, diameter 15.5mm, width 4.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4.9mm_P7.5mm +Varistor, diameter 15.5mm, width 4.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W4mm_P7.5mm +Varistor, diameter 15.5mm, width 4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5.2mm_P7.5mm +Varistor, diameter 15.5mm, width 5.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5.4mm_P7.5mm +Varistor, diameter 15.5mm, width 5.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5.9mm_P7.5mm +Varistor, diameter 15.5mm, width 5.9mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W5mm_P7.5mm +Varistor, diameter 15.5mm, width 5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.1mm_P7.5mm +Varistor, diameter 15.5mm, width 6.1mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.3mm_P7.5mm +Varistor, diameter 15.5mm, width 6.3mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.4mm_P7.5mm +Varistor, diameter 15.5mm, width 6.4mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W6.8mm_P7.5mm +Varistor, diameter 15.5mm, width 6.8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W7.2mm_P7.5mm +Varistor, diameter 15.5mm, width 7.2mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W7.5mm_P7.5mm +Varistor, diameter 15.5mm, width 7.5mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W8mm_P7.5mm +Varistor, diameter 15.5mm, width 8mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D15.5mm_W11mm_P7.5mm +Varistor, diameter 15.5mm, width 11mm, pitch 7.5mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D16.5mm_W6.7mm_P7.5mm +Varistor, diameter 16.5mm, width 6.7mm, pitch 5mm, https://katalog.we-online.de/pbs/datasheet/820542711.pdf +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.3mm_P10mm +Varistor, diameter 21.5mm, width 4.3mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.4mm_P10mm +Varistor, diameter 21.5mm, width 4.4mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.5mm_P10mm +Varistor, diameter 21.5mm, width 4.5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.6mm_P10mm +Varistor, diameter 21.5mm, width 4.6mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.7mm_P10mm +Varistor, diameter 21.5mm, width 4.7mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.8mm_P10mm +Varistor, diameter 21.5mm, width 4.8mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W4.9mm_P10mm +Varistor, diameter 21.5mm, width 4.9mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.1mm_P10mm +Varistor, diameter 21.5mm, width 5.1mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.3mm_P10mm +Varistor, diameter 21.5mm, width 5.3mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.4mm_P10mm +Varistor, diameter 21.5mm, width 5.4mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.6mm_P10mm +Varistor, diameter 21.5mm, width 5.6mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5.8mm_P10mm +Varistor, diameter 21.5mm, width 5.8mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W5mm_P10mm +Varistor, diameter 21.5mm, width 5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.1mm_P7.5mm +varistor +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.3mm_P10mm +Varistor, diameter 21.5mm, width 6.3mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.5mm_P10mm +Varistor, diameter 21.5mm, width 6.5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.7mm_P10mm +Varistor, diameter 21.5mm, width 6.7mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W6.8mm_P10mm +Varistor, diameter 21.5mm, width 6.8mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W7.1mm_P10mm +Varistor, diameter 21.5mm, width 7.1mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W7.5mm_P10mm +Varistor, diameter 21.5mm, width 7.5mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W7.9mm_P10mm +Varistor, diameter 21.5mm, width 7.9mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W8.4mm_P10mm +Varistor, diameter 21.5mm, width 8.4mm, pitch 10mm +varistor SIOV +0 +2 +2 +Varistor +RV_Disc_D21.5mm_W11.4mm_P10mm +Varistor, diameter 21.5mm, width 11.4mm, pitch 10mm +varistor SIOV +0 +2 +2 diff --git a/Sofle_RGB_v3/PCB/fp-lib-table b/Sofle_RGB_v3/PCB/fp-lib-table new file mode 100644 index 00000000..f585d25e --- /dev/null +++ b/Sofle_RGB_v3/PCB/fp-lib-table @@ -0,0 +1,3 @@ +(fp_lib_table + (lib (name SofleRGB)(type KiCad)(uri ${KIPRJMOD}/SofleRGB.pretty)(options "")(descr "")) +) diff --git a/Sofle_RGB_v3/PCB/sym-lib-table b/Sofle_RGB_v3/PCB/sym-lib-table new file mode 100644 index 00000000..f9963da4 --- /dev/null +++ b/Sofle_RGB_v3/PCB/sym-lib-table @@ -0,0 +1,4 @@ +(sym_lib_table + (lib (name SofleKeyboard-rescue)(type Legacy)(uri ${KIPRJMOD}/SofleKeyboard-rescue.lib)(options "")(descr "")) + (lib (name SofleKeyboard)(type Legacy)(uri ${KIPRJMOD}/SofleKeyboard.lib)(options "")(descr "")) +) From f7f0f6266251d9a5ab6b19d329ba5e95527620c7 Mon Sep 17 00:00:00 2001 From: Jesus Climent Date: Mon, 27 Dec 2021 18:47:37 +0000 Subject: [PATCH 2/2] More fixes on GND/VCC tracks. --- Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb | 9459 ++++++------- Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak | 12534 ++++++++--------- 2 files changed, 10998 insertions(+), 10995 deletions(-) diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb index cf46c6f4..7babddda 100644 --- a/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb @@ -3,7 +3,7 @@ (general (thickness 1.6) (drawings 350) - (tracks 3564) + (tracks 3567) (zones 0) (modules 96) (nets 95) @@ -308,6 +308,142 @@ (add_net VCC) ) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A06) + (at 139.5 123.7 180) + (path /5F7D72AF) + (fp_text reference SW28 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) + ) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9724D) (at 128.75 45.775 270) (descr "Resitance 3 pas") @@ -320,22 +456,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 5 row0)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -363,22 +499,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 5 row0)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -406,22 +542,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 5 row0)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -449,22 +585,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 5 row0)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -492,22 +628,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 5 row0)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -535,22 +671,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 5 row0)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -578,22 +714,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 7 row1)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -621,22 +757,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 7 row1)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -664,22 +800,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 7 row1)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -707,22 +843,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 7 row1)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -750,22 +886,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 7 row1)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -793,22 +929,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 7 row1)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -836,23 +972,23 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 9 row2)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) (net 18 "Net-(D13-Pad2)")) @@ -879,22 +1015,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 9 row2)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -922,22 +1058,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 9 row2)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -965,22 +1101,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 9 row2)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1008,22 +1144,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 9 row2)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1051,22 +1187,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 9 row2)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1094,22 +1230,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 11 row3)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1137,22 +1273,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 11 row3)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1180,22 +1316,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 11 row3)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1223,22 +1359,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 11 row3)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1266,22 +1402,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 11 row3)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1309,22 +1445,22 @@ (fp_text value D (at -0.6 0 90) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 11 row3)) (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1352,22 +1488,22 @@ (fp_text value D (at -0.6 0) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 2 row4)) (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1395,22 +1531,22 @@ (fp_text value D (at -0.6 0) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 2 row4)) (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1438,22 +1574,22 @@ (fp_text value D (at -0.6 0) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 2 row4)) (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) @@ -1481,49 +1617,6 @@ (fp_text value D (at -0.6 0) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 32 "Net-(D28-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 32 "Net-(D28-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) - ) - - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973B9) - (at 125.775 121.6) - (descr "Resitance 3 pas") - (tags R) - (path /5B734F9E) - (autoplace_cost180 10) - (fp_text reference D29 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) @@ -1540,14 +1633,14 @@ (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 44 "Net-(D29-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 2 row4)) (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 44 "Net-(D29-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl (at (xyz 0 0 0)) (scale (xyz 0.22 0.15 0.15)) @@ -1555,13 +1648,13 @@ ) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5D8B2928) - (at 125.805 119.02) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973B9) + (at 125.775 121.6) (descr "Resitance 3 pas") (tags R) - (path /5D956FE1) + (path /5B734F9E) (autoplace_cost180 10) - (fp_text reference D30 (at 0.5 0) (layer F.Fab) hide + (fp_text reference D29 (at 0.5 0) (layer F.Fab) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) (fp_text value D (at -0.6 0) (layer F.Fab) hide @@ -1583,14 +1676,14 @@ (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) (net 2 row4)) (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 52 "Net-(D30-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 52 "Net-(D30-Pad2)")) (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl (at (xyz 0 0 0)) (scale (xyz 0.22 0.15 0.15)) @@ -1598,39 +1691,82 @@ ) ) - (module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5FDCA436) (tstamp 5BEDDC08) - (at 107.9 81.1 180) - (path /5B74AE32) - (fp_text reference J1 (at 0 6.9 180) (layer F.SilkS) - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5D8B2928) + (at 125.805 119.02) + (descr "Resitance 3 pas") + (tags R) + (path /5D956FE1) + (autoplace_cost180 10) + (fp_text reference D30 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5FDCA436) (tstamp 5BEDDC08) + (at 107.9 81.1 180) + (path /5B74AE32) + (fp_text reference J1 (at 0 6.9 180) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) ) (fp_text value LED (at 0 7.62 180) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) (fp_text user GND (at -2.1836 5.0524 180) (layer F.SilkS) (effects (font (size 0.8 0.8) (thickness 0.15))) ) @@ -1663,20 +1799,20 @@ (fp_text value 4PIN (at 0 14 90) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) (effects (font (size 1 1) (thickness 0.15))) ) (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) (pad 4 thru_hole oval (at -2.1 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) (net 57 /i2c_c) (clearance 0.15)) (pad 1 thru_hole oval (at 2.1 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) @@ -1715,14 +1851,14 @@ (fp_text value OLED (at 3.81 1.27) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) - (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) - (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) (pad 4 thru_hole circle (at 7.62 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) (net 51 "Net-(J3-Pad4)")) (pad 3 thru_hole circle (at 5.08 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) @@ -1743,10 +1879,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 34 GND) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -1768,10 +1904,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 33 VCC) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -1793,10 +1929,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 42 SCL) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -1818,10 +1954,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 40 SDA) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -1843,10 +1979,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) (net 40 SDA) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) @@ -1868,10 +2004,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) (net 42 SCL) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) @@ -1893,10 +2029,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) (net 33 VCC) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) @@ -1918,10 +2054,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) (net 34 GND) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) @@ -1943,10 +2079,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 64 lights) (clearance 0.1905)) (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -1968,10 +2104,10 @@ (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 41 LED) (clearance 0.1905)) (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -1995,14 +2131,14 @@ (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) - (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) (fp_text user P1 (at 0.2 -1.7 270) (layer B.SilkS) (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) ) @@ -2032,14 +2168,14 @@ (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) - (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) (fp_text user P1 (at -0.1 1.7 270) (layer B.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) @@ -2072,14 +2208,14 @@ (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) (fp_text user R1 (at 0 -0.011965 180) (layer B.SilkS) (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) ) @@ -2111,14 +2247,14 @@ (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) (fp_text user R2 (at 0 0 180) (layer B.SilkS) (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) ) @@ -2147,23 +2283,23 @@ (fp_text value SW_RST (at 0 2 90) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) (fp_line (start -3 -1.8) (end 2.9 -1.8) (layer B.SilkS) (width 0.15)) - (fp_text user RESET (at 0 0 270) (layer F.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15))) - ) - (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) (effects (font (size 0.8 0.8) (thickness 0.15))) ) (pad 2 thru_hole circle (at 3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) @@ -2183,40 +2319,40 @@ (fp_text value Rotary_Encoder_Switch (at 0 7.9) (layer F.Fab) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) - (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) - (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) - (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) - (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) - (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) - (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) - (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) - (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) - (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) - (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) - (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) - (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) - (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) - (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) - (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) - (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) (fp_line (start -0.5 0) (end 0.5 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) + (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) + (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) (pad A thru_hole circle (at -7.5 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) (net 56 ENCA)) (pad C thru_hole circle (at -7.5 0) (size 2 2) (drill 1) (layers *.Cu *.Mask) @@ -2334,28 +2470,28 @@ (fp_text value ProMicro (at 0 -0.8) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) - (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) - (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) (fp_line (start -10.09 14.44) (end -10.09 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) (pad 22 thru_hole circle (at -7.521185 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) (net 43 RESET)) (pad 10 thru_hole circle (at 7.718815 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) @@ -2464,11 +2600,11 @@ (fp_text value jumper (at 0 1.524 90) (layer F.SilkS) hide (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) (net 47 DATA) (clearance 0.1905)) (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) @@ -2489,18 +2625,18 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) @@ -2528,18 +2664,18 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) @@ -2567,18 +2703,18 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) @@ -2606,18 +2742,18 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) @@ -2645,18 +2781,18 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) @@ -2684,21 +2820,21 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 63 "Net-(D35-Pad1)")) (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 94 BL)) @@ -2723,18 +2859,18 @@ (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) @@ -2762,86 +2898,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -2898,86 +3034,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -3034,86 +3170,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 180) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -3170,86 +3306,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -3306,222 +3442,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 88 "Net-(SW21-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 82 "Net-(SW15-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 88 "Net-(SW21-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 82 "Net-(SW15-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 26 "Net-(D21-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 26 "Net-(D21-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985A6) - (at 215.7 71.3 180) - (path /5B723AD3) - (fp_text reference SW12 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -3537,127 +3537,263 @@ (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 73 "Net-(SW12-Pad1)")) + (net 88 "Net-(SW21-Pad1)")) (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 79 "Net-(SW12-Pad3)")) + (net 82 "Net-(SW15-Pad1)")) (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 73 "Net-(SW12-Pad1)")) + (net 88 "Net-(SW21-Pad1)")) (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 79 "Net-(SW12-Pad3)")) + (net 82 "Net-(SW15-Pad1)")) (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) + (net 38 col3)) (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 17 "Net-(D12-Pad2)")) + (net 26 "Net-(D21-Pad2)")) (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) + (net 38 col3)) (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 17 "Net-(D12-Pad2)")) + (net 26 "Net-(D21-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98560) - (at 196.7 71.3 180) - (path /5B72387D) - (fp_text reference SW11 (at 0 3 unlocked) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985A6) + (at 215.7 71.3 180) + (path /5B723AD3) + (fp_text reference SW12 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 17 "Net-(D12-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 17 "Net-(D12-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98560) + (at 196.7 71.3 180) + (path /5B72387D) + (fp_text reference SW11 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -3714,86 +3850,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -3850,222 +3986,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 65 "Net-(SW1-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 65 "Net-(SW1-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 3 "Net-(D2-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 3 "Net-(D2-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F7EF4F0) - (at 177.6 123.8 180) - (path /5F7D72C1) - (fp_text reference SW30 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -4081,127 +4081,263 @@ (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 91 "Net-(SW24-Pad3)")) + (net 65 "Net-(SW1-Pad3)")) (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 94 BL)) + (net 67 "Net-(SW2-Pad3)")) (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 91 "Net-(SW24-Pad3)")) + (net 65 "Net-(SW1-Pad3)")) (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 94 BL)) + (net 67 "Net-(SW2-Pad3)")) (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) + (net 39 col4)) (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 52 "Net-(D30-Pad2)")) + (net 3 "Net-(D2-Pad2)")) (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) + (net 39 col4)) (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 52 "Net-(D30-Pad2)")) + (net 3 "Net-(D2-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A4C) - (at 158.6 121.29 180) - (path /5F7D72A9) - (fp_text reference SW29 (at 0 3 unlocked) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F7EF4F0) + (at 177.6 123.8 180) + (path /5F7D72C1) + (fp_text reference SW30 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A4C) + (at 158.6 121.29 180) + (path /5F7D72A9) + (fp_text reference SW29 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -4249,142 +4385,6 @@ (net 44 "Net-(D29-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A06) - (at 139.5 123.7 180) - (path /5F7D72AF) - (fp_text reference SW28 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 89 "Net-(SW22-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 93 "Net-(SW28-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 89 "Net-(SW22-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 93 "Net-(SW28-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 32 "Net-(D28-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 32 "Net-(D28-Pad2)")) - ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F806503) (at 117.6 128.4 195) (path /5F7D72B5) @@ -4394,86 +4394,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.199999 15) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -4504,112 +4504,112 @@ (net 33 VCC)) (pad "" np_thru_hole circle (at 2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 0 0 285) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58 15) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 31 "Net-(D27-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12 15) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 31 "Net-(D27-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9897A) - (at 96.71 133.4 120) - (path /5F7D72BB) - (fp_text reference SW26 (at 0 3 300 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 120) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (pad 6 smd rect (at 5.7 -5.12 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 15) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 31 "Net-(D27-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 15) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 31 "Net-(D27-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9897A) + (at 96.71 133.4 120) + (path /5F7D72BB) + (fp_text reference SW26 (at 0 3 300 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -4666,86 +4666,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -4802,222 +4802,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 87 "Net-(SW20-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 87 "Net-(SW20-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 25 "Net-(D20-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 25 "Net-(D20-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98790) - (at 120.5 107.1 180) - (path /5F7D018F) - (fp_text reference SW19 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -5033,127 +4897,263 @@ (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 86 "Net-(SW19-Pad1)")) + (net 81 "Net-(SW14-Pad3)")) (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 80 "Net-(SW13-Pad1)")) + (net 87 "Net-(SW20-Pad3)")) (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 86 "Net-(SW19-Pad1)")) + (net 81 "Net-(SW14-Pad3)")) (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 80 "Net-(SW13-Pad1)")) + (net 87 "Net-(SW20-Pad3)")) (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) + (net 39 col4)) (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 24 "Net-(D19-Pad2)")) + (net 25 "Net-(D20-Pad2)")) (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) + (net 39 col4)) (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 24 "Net-(D19-Pad2)")) + (net 25 "Net-(D20-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE986BE) - (at 177.6 85.6 180) - (path /5F7D01A1) - (fp_text reference SW16 (at 0 3 unlocked) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98790) + (at 120.5 107.1 180) + (path /5F7D018F) + (fp_text reference SW19 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE986BE) + (at 177.6 85.6 180) + (path /5F7D01A1) + (fp_text reference SW16 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -5210,86 +5210,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -5346,225 +5346,89 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_text user SW15 (at 7.1 8.2) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 19 "Net-(D14-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 19 "Net-(D14-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985EC) - (at 120.5 88.1 180) - (path /5F7D01B3) - (fp_text reference SW13 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_text user SW15 (at 7.1 8.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -5580,127 +5444,263 @@ (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 80 "Net-(SW13-Pad1)")) + (net 75 "Net-(SW14-Pad1)")) (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 74 "Net-(SW13-Pad3)")) + (net 81 "Net-(SW14-Pad3)")) (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 80 "Net-(SW13-Pad1)")) + (net 75 "Net-(SW14-Pad1)")) (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 74 "Net-(SW13-Pad3)")) + (net 81 "Net-(SW14-Pad3)")) (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) + (net 39 col4)) (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 18 "Net-(D13-Pad2)")) + (net 19 "Net-(D14-Pad2)")) (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) + (net 39 col4)) (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 18 "Net-(D13-Pad2)")) + (net 19 "Net-(D14-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9851A) - (at 177.6 66.5 180) - (path /5B7237A6) - (fp_text reference SW10 (at 0 3 unlocked) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985EC) + (at 120.5 88.1 180) + (path /5F7D01B3) + (fp_text reference SW13 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9851A) + (at 177.6 66.5 180) + (path /5B7237A6) + (fp_text reference SW10 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -5757,86 +5757,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -5893,222 +5893,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 13 "Net-(D8-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 13 "Net-(D8-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98448) - (at 120.5 69.1 180) - (path /5B723C9D) - (fp_text reference SW7 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -6124,127 +5988,263 @@ (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 74 "Net-(SW13-Pad3)")) + (net 67 "Net-(SW2-Pad3)")) (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 66 "Net-(SW1-Pad1)")) + (net 75 "Net-(SW14-Pad1)")) (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 34 GND)) (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 74 "Net-(SW13-Pad3)")) + (net 67 "Net-(SW2-Pad3)")) (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 66 "Net-(SW1-Pad1)")) + (net 75 "Net-(SW14-Pad1)")) (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) + (net 39 col4)) (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 12 "Net-(D7-Pad2)")) + (net 13 "Net-(D8-Pad2)")) (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) + (net 39 col4)) (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 12 "Net-(D7-Pad2)")) + (net 13 "Net-(D8-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE983BC) - (at 196.7 52.4 180) - (path /5B722B51) - (fp_text reference SW5 (at 0 3 unlocked) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98448) + (at 120.5 69.1 180) + (path /5B723C9D) + (fp_text reference SW7 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE983BC) + (at 196.7 52.4 180) + (path /5B722B51) + (fp_text reference SW5 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -6301,86 +6301,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -6437,86 +6437,86 @@ (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -6561,98 +6561,98 @@ (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 4 "Net-(D3-Pad2)")) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982A4) - (at 120.5 50 180) - (path /5B7225DA) - (fp_text reference SW1 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (net 4 "Net-(D3-Pad2)")) + ) + + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982A4) + (at 120.5 50 180) + (path /5B7225DA) + (fp_text reference SW1 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) @@ -8187,13 +8187,13 @@ (segment (start 112.1998 120.6248) (end 111.595198 120.6248) (width 0.25) (layer B.Cu) (net 31)) (segment (start 111.595198 120.6248) (end 110.984999 121.234999) (width 0.25) (layer B.Cu) (net 31)) (segment (start 110.984999 121.234999) (end 111.595198 120.6248) (width 0.25) (layer F.Cu) (net 31)) - (segment (start 111.506272 132.703822) (end 111.506272 131.668546) (width 0.25) (layer F.Cu) (net 31)) - (segment (start 111.506272 131.668546) (end 108.474998 128.637272) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.074998 122.988802) (end 109.828801 121.234999) (width 0.25) (layer F.Cu) (net 31)) (segment (start 108.474998 124.952002) (end 108.074998 124.552002) (width 0.25) (layer F.Cu) (net 31)) - (segment (start 108.074998 124.552002) (end 108.074998 123.828319) (width 0.25) (layer F.Cu) (net 31)) - (segment (start 110.668318 121.234999) (end 110.984999 121.234999) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 109.828801 121.234999) (end 110.984999 121.234999) (width 0.25) (layer F.Cu) (net 31)) (segment (start 108.474998 128.637272) (end 108.474998 124.952002) (width 0.25) (layer F.Cu) (net 31)) - (segment (start 108.074998 123.828319) (end 110.668318 121.234999) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 108.074998 124.552002) (end 108.074998 122.988802) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.506272 131.668546) (end 108.474998 128.637272) (width 0.25) (layer F.Cu) (net 31)) + (segment (start 111.506272 132.703822) (end 111.506272 131.668546) (width 0.25) (layer F.Cu) (net 31)) (via (at 141.108 131.259) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 32)) (segment (start 142.771 131.259) (end 141.108 131.259) (width 0.25) (layer B.Cu) (net 32)) (segment (start 146.5 126.28) (end 146.5 127.53) (width 0.25) (layer B.Cu) (net 32)) @@ -8454,54 +8454,19 @@ (segment (start 129.45 76.023) (end 129.45 69.062002) (width 0.5) (layer F.Cu) (net 33)) (segment (start 131.95 63.4) (end 135.225 60.125) (width 0.5) (layer F.Cu) (net 33)) (segment (start 129.45 69.062002) (end 128.849999 68.462001) (width 0.5) (layer F.Cu) (net 33)) - (segment (start 187.25 119.445) (end 189.1 119.445) (width 0.25) (layer F.Cu) (net 33)) (via (at 189.95 118.65) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 189.1 119.445) (end 189.895 118.65) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 189.895 118.65) (end 189.95 118.65) (width 0.25) (layer F.Cu) (net 33)) (via (at 98.9664 127.6462) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) (via (at 104.5036 128.3144) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 189.95 119.745) (end 189.95 118.65) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 188.5 121.195) (end 189.95 119.745) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 187.25 121.195) (end 188.5 121.195) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 175.2 119.175) (end 173.618 119.175) (width 0.25) (layer B.Cu) (net 33)) - (via (at 172.7818 117.399) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 173.618 119.175) (end 172.7818 118.3388) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 172.7818 118.3388) (end 172.7818 117.399) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 175.174 117.399) (end 175.2 117.425) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 172.7818 117.399) (end 175.174 117.399) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 172.7818 117.399) (end 167.8288 112.446) (width 0.25) (layer F.Cu) (net 33)) + (via (at 172.7818 117.399) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33) (status 1000000)) (via (at 167.8034 111.8618) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 167.8288 112.446) (end 167.8288 111.8872) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 167.8288 111.8872) (end 167.8034 111.8618) (width 0.25) (layer F.Cu) (net 33)) (via (at 166.42499 111.86501) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 167.8034 111.8618) (end 166.4282 111.8618) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 166.4282 111.8618) (end 166.42499 111.86501) (width 0.25) (layer B.Cu) (net 33)) - (via (at 135.669468 118.748132) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 135.096599 118.175263) (end 135.669468 118.748132) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 135.096599 117.705799) (end 135.096599 118.175263) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 137.1 117.325) (end 135.477398 117.325) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 135.477398 117.325) (end 135.096599 117.705799) (width 0.25) (layer F.Cu) (net 33)) (segment (start 136.773132 118.748132) (end 137.1 119.075) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 135.669468 118.748132) (end 136.773132 118.748132) (width 0.25) (layer B.Cu) (net 33)) (segment (start 151.2836 116.2658) (end 151.2836 117.3876) (width 0.5) (layer F.Cu) (net 33)) (segment (start 152.6344 114.915) (end 151.2836 116.2658) (width 0.5) (layer F.Cu) (net 33)) (segment (start 152.7972 114.915) (end 152.6344 114.915) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 151.2836 119.1376) (end 153.7274 119.1376) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 154.4084 118.4566) (end 154.4084 117.8724) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 153.7274 119.1376) (end 154.4084 118.4566) (width 0.25) (layer B.Cu) (net 33)) (via (at 153.2948 114.915) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 154.4084 117.8724) (end 153.2948 116.7588) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 153.2948 116.7588) (end 153.2948 114.915) (width 0.25) (layer B.Cu) (net 33)) (segment (start 156.2 114.915) (end 153.2948 114.915) (width 0.5) (layer F.Cu) (net 33)) (segment (start 153.2948 114.915) (end 152.7972 114.915) (width 0.5) (layer F.Cu) (net 33)) - (via (at 128.025 113.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 128 113.25) (end 128.025 113.25) (width 0.25) (layer F.Cu) (net 33)) - (via (at 130.1606 115.4178) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) - (segment (start 135.096599 117.705799) (end 132.8086 115.4178) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 130.443442 115.4178) (end 130.1606 115.4178) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 130.1606 115.3856) (end 130.1606 115.4178) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 132.8086 115.4178) (end 130.443442 115.4178) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 128.025 113.25) (end 130.1606 115.3856) (width 0.25) (layer B.Cu) (net 33)) (segment (start 153.782 39.272) (end 153.8 39.29) (width 0.5) (layer F.Cu) (net 33)) (segment (start 153.782 38.75) (end 153.782 39.272) (width 0.5) (layer F.Cu) (net 33)) (segment (start 171.265 78.115) (end 167.325 78.115) (width 0.5) (layer F.Cu) (net 33)) @@ -8515,7 +8480,6 @@ (segment (start 100.42262 68.79962) (end 100.42262 68.822612) (width 0.25) (layer F.Cu) (net 33)) (segment (start 100.42262 68.79962) (end 100.400388 68.79962) (width 0.5) (layer F.Cu) (net 33)) (segment (start 101.7 68.79962) (end 100.42262 68.79962) (width 0.5) (layer F.Cu) (net 33)) - (segment (start 128 113.25) (end 125.883 115.367) (width 0.25) (layer F.Cu) (net 33)) (segment (start 172.749999 98.837999) (end 172.849999 98.837999) (width 0.5) (layer F.Cu) (net 33)) (segment (start 171.33699 97.42499) (end 172.749999 98.837999) (width 0.5) (layer F.Cu) (net 33)) (segment (start 192.808 62.125) (end 192.532 61.849) (width 0.5) (layer F.Cu) (net 33)) @@ -8546,14 +8510,7 @@ (segment (start 122.1355 98.4) (end 118.432842 98.4) (width 0.5) (layer F.Cu) (net 33)) (segment (start 117.132842 99.7) (end 116.85 99.7) (width 0.5) (layer F.Cu) (net 33)) (segment (start 122.1355 98.4) (end 124.15 98.4) (width 0.5) (layer F.Cu) (net 33)) - (segment (start 128 101.9015) (end 128 113.25) (width 0.5) (layer F.Cu) (net 33)) (segment (start 124.15 98.4) (end 124.4985 98.4) (width 0.5) (layer F.Cu) (net 33)) - (segment (start 124.4985 98.4) (end 128 101.9015) (width 0.5) (layer F.Cu) (net 33)) - (segment (start 136.3326 120.904) (end 135.669468 120.240868) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 135.669468 120.240868) (end 135.669468 118.748132) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 150.241 120.904) (end 136.3326 120.904) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 151.2836 119.1376) (end 151.2836 119.8614) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 151.2836 119.8614) (end 150.241 120.904) (width 0.25) (layer B.Cu) (net 33)) (segment (start 154.83499 111.86501) (end 166.42499 111.86501) (width 0.5) (layer F.Cu) (net 33)) (segment (start 152.7972 114.915) (end 152.7972 113.9028) (width 0.5) (layer F.Cu) (net 33)) (segment (start 152.7972 113.9028) (end 154.83499 111.86501) (width 0.5) (layer F.Cu) (net 33)) @@ -8575,35 +8532,6 @@ (segment (start 192.0875 65.1375) (end 193.3 63.925) (width 0.5) (layer B.Cu) (net 33)) (segment (start 194.3 66.675) (end 192.7225 66.675) (width 0.5) (layer B.Cu) (net 33)) (segment (start 192.7225 66.675) (end 192.0875 66.04) (width 0.5) (layer B.Cu) (net 33)) - (segment (start 156.2 117.5485) (end 156.2 116.665) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 154.4084 118.4566) (end 155.2919 118.4566) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 155.2919 118.4566) (end 156.2 117.5485) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 101.030912 128.134039) (end 100.196873 127.3) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 99.3126 127.3) (end 98.9664 127.6462) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 100.196873 127.3) (end 99.3126 127.3) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 99.515367 129.009039) (end 98.6 128.093672) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 98.6 128.0126) (end 98.9664 127.6462) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 98.6 128.093672) (end 98.6 128.0126) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 101.545613 127.619338) (end 103.719338 127.619338) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 101.030912 128.134039) (end 101.545613 127.619338) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 104.4144 128.3144) (end 104.5036 128.3144) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 103.719338 127.619338) (end 104.4144 128.3144) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 104.5036 128.3144) (end 109.9856 128.3144) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 111.05 127.25) (end 111.05 125.005) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 109.9856 128.3144) (end 111.05 127.25) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 111.813828 122.863389) (end 113.631807 122.863389) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 111.422217 123.255) (end 111.813828 122.863389) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 111.05 123.255) (end 111.422217 123.255) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 113.523025 121.275487) (end 113.523025 120.676975) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 113.631807 122.863389) (end 113.631807 121.681468) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 113.631807 121.681468) (end 113.523025 121.275487) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 118.833 115.367) (end 119.667 115.367) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 113.523025 120.676975) (end 118.833 115.367) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 125.883 115.367) (end 119.667 115.367) (width 0.25) (layer F.Cu) (net 33)) - (segment (start 113.633499 125.005) (end 114.08474 124.553759) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 111.05 125.005) (end 113.633499 125.005) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 111.05 125.005) (end 109.305 125.005) (width 0.25) (layer B.Cu) (net 33)) - (segment (start 109.305 125.005) (end 108.6 124.3) (width 0.25) (layer B.Cu) (net 33)) (via (at 108.6 124.3) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) (segment (start 109.284728 123.255) (end 108.6 123.939728) (width 0.25) (layer F.Cu) (net 33)) (segment (start 108.6 123.939728) (end 108.6 124.3) (width 0.25) (layer F.Cu) (net 33)) @@ -8706,6 +8634,83 @@ (segment (start 194.62501 44.12499) (end 194.3 44.45) (width 0.5) (layer F.Cu) (net 33)) (segment (start 205.74519 44.12499) (end 194.62501 44.12499) (width 0.5) (layer F.Cu) (net 33)) (segment (start 205.994 44.3738) (end 205.74519 44.12499) (width 0.5) (layer F.Cu) (net 33)) + (via (at 135.4074 118.6942) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 135.7882 119.075) (end 135.4074 118.6942) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 119.075) (end 135.7882 119.075) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.082799 117.307799) (end 137.1 117.325) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.971599 117.645799) (end 135.309599 117.307799) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 134.971599 118.258399) (end 134.971599 117.645799) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.309599 117.307799) (end 137.082799 117.307799) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.4074 118.6942) (end 134.971599 118.258399) (width 0.5) (layer F.Cu) (net 33)) + (via (at 129.921 115.6716) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 132.3848 115.6716) (end 129.921 115.6716) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 135.4074 118.6942) (end 132.3848 115.6716) (width 0.5) (layer F.Cu) (net 33)) + (via (at 128.025 113.25) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 33)) + (segment (start 128.025 113.2496) (end 128.025 113.25) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.025 101.9265) (end 127.76835 101.66985) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 127.76835 101.66985) (end 128 101.9015) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 129.921 115.09599) (end 128.07501 113.25) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 129.921 115.6716) (end 129.921 115.09599) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 113.388883 122.620465) (end 113.631807 122.863389) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 113.388883 120.797931) (end 113.388883 122.620465) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 118.831807 115.355007) (end 113.388883 120.797931) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 125.919993 115.355007) (end 118.831807 115.355007) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.025 113.25) (end 125.919993 115.355007) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.025 101.9265) (end 127.56515 101.46665) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 128.025 113.25) (end 128.025 101.9265) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 127.56515 101.46665) (end 127.76835 101.66985) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 124.4985 98.4) (end 127.56515 101.46665) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 151.2836 119.489902) (end 151.2836 119.1376) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 150.108501 120.665001) (end 151.2836 119.489902) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 146.977997 120.665001) (end 150.108501 120.665001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 146.668788 120.97421) (end 146.977997 120.665001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.532934 120.97421) (end 137.1 120.541276) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 138.93201 120.97421) (end 137.532934 120.97421) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 137.1 120.541276) (end 137.1 119.075) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 138.93201 120.97421) (end 146.668788 120.97421) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.023224 116.665) (end 156.2 116.665) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.550624 119.1376) (end 156.023224 116.665) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 151.2836 119.1376) (end 153.550624 119.1376) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 156.136799 116.728201) (end 156.2 116.665) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 154.486599 116.728201) (end 156.136799 116.728201) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.2948 115.536402) (end 154.486599 116.728201) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 153.2948 114.915) (end 153.2948 115.536402) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 167.80019 111.86501) (end 167.8034 111.8618) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 166.42499 111.86501) (end 167.80019 111.86501) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 172.7818 118.208602) (end 172.7818 117.399) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 173.748198 119.175) (end 172.7818 118.208602) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 175.2 119.175) (end 173.748198 119.175) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 172.8078 117.425) (end 172.7818 117.399) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 175.2 117.425) (end 172.8078 117.425) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 167.8034 112.4206) (end 167.8034 111.8618) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 172.7818 117.399) (end 167.8034 112.4206) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 188.045 118.65) (end 187.25 119.445) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 189.95 118.65) (end 188.045 118.65) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 189.95 119.995) (end 189.95 118.65) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 188.75 121.195) (end 189.95 119.995) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 187.25 121.195) (end 188.75 121.195) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 109.305 125.005) (end 108.6 124.3) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 111.05 125.005) (end 109.305 125.005) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.9664 128.460072) (end 99.515367 129.009039) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 98.9664 127.6462) (end 98.9664 128.460072) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 99.064201 127.548399) (end 98.9664 127.6462) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 100.445272 127.548399) (end 99.064201 127.548399) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.030912 128.134039) (end 100.445272 127.548399) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 103.674396 127.485196) (end 104.5036 128.3144) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.679755 127.485196) (end 103.674396 127.485196) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 101.030912 128.134039) (end 101.679755 127.485196) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 111.05 127.312002) (end 111.05 125.005) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 110.612001 127.750001) (end 111.05 127.312002) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 109.872414 128.3144) (end 110.436813 127.750001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 110.436813 127.750001) (end 110.612001 127.750001) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 104.5036 128.3144) (end 109.872414 128.3144) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 111.441611 122.863389) (end 111.05 123.255) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 113.631807 122.863389) (end 111.441611 122.863389) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 108.650008 123.904722) (end 108.650008 124.3) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 109.29973 123.255) (end 108.650008 123.904722) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 111.05 123.255) (end 109.29973 123.255) (width 0.5) (layer F.Cu) (net 33)) + (segment (start 113.633499 125.005) (end 114.08474 124.553759) (width 0.5) (layer B.Cu) (net 33)) + (segment (start 111.05 125.005) (end 113.633499 125.005) (width 0.5) (layer B.Cu) (net 33)) (segment (start 218.1 47.775) (end 218.475 47.775) (width 0.5) (layer F.Cu) (net 34)) (segment (start 218.325 46.25) (end 218.1 46.025) (width 0.5) (layer B.Cu) (net 34)) (segment (start 218.1 47.775) (end 218.125012 47.800012) (width 0.5) (layer F.Cu) (net 34)) @@ -9109,14 +9114,8 @@ (segment (start 101.946161 133.165961) (end 102.878 134.0978) (width 0.25) (layer F.Cu) (net 34)) (segment (start 101.915367 133.165961) (end 101.946161 133.165961) (width 0.25) (layer F.Cu) (net 34)) (segment (start 106.65 125.005) (end 104.681 125.005) (width 0.25) (layer F.Cu) (net 34)) - (segment (start 120 120.2) (end 120 121.1) (width 0.25) (layer B.Cu) (net 34)) - (segment (start 119.478943 121.621057) (end 118.268251 121.621057) (width 0.25) (layer B.Cu) (net 34)) - (segment (start 120 121.1) (end 119.478943 121.621057) (width 0.25) (layer B.Cu) (net 34)) - (segment (start 120.401227 123.311427) (end 120.909801 123.820001) (width 0.25) (layer F.Cu) (net 34)) - (segment (start 118.721184 123.311427) (end 120.401227 123.311427) (width 0.25) (layer F.Cu) (net 34)) (segment (start 120.909801 123.820001) (end 120.909801 121.109801) (width 0.5) (layer B.Cu) (net 34)) (segment (start 120.909801 121.109801) (end 119.9 120.1) (width 0.5) (layer B.Cu) (net 34)) - (segment (start 119.9 120.1) (end 120 120.2) (width 0.25) (layer B.Cu) (net 34)) (segment (start 161 116.665) (end 161.635 116.665) (width 0.5) (layer F.Cu) (net 34)) (segment (start 163.5108 112.5814) (end 163.5108 114.7892) (width 0.5) (layer F.Cu) (net 34)) (segment (start 163.5108 114.7892) (end 162.6 115.7) (width 0.5) (layer F.Cu) (net 34)) @@ -9315,6 +9314,12 @@ (segment (start 152.196 53.2138) (end 148.5 53.2138) (width 0.5) (layer B.Cu) (net 34)) (segment (start 153.3262 53.2138) (end 152.196 53.2138) (width 0.5) (layer B.Cu) (net 34)) (via (at 146.939 46.2788) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 34)) + (segment (start 118.378943 121.621057) (end 119.9 120.1) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 118.268251 121.621057) (end 118.378943 121.621057) (width 0.5) (layer B.Cu) (net 34)) + (segment (start 120.401227 123.311427) (end 120.909801 123.820001) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 118.721184 123.311427) (end 120.401227 123.311427) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 106.455 125.2) (end 106.65 125.005) (width 0.5) (layer F.Cu) (net 34)) + (segment (start 104.6 125.2) (end 106.455 125.2) (width 0.5) (layer F.Cu) (net 34)) (segment (start 220.5 59.75) (end 220.5 58.42) (width 0.25) (layer F.Cu) (net 35) (tstamp 5F754BC2)) (segment (start 220.5 58.42) (end 221.4 57.52) (width 0.25) (layer F.Cu) (net 35) (tstamp 5F754BC3)) (via (at 220.5 59.75) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 35) (tstamp 5F754BC8)) @@ -10822,13 +10827,9 @@ (segment (start 162.013188 94.69) (end 161.45 94.69) (width 0.25) (layer B.Cu) (net 88)) (segment (start 161 97.565) (end 162.725 97.565) (width 0.25) (layer B.Cu) (net 88)) (segment (start 162.725 97.565) (end 163.3 96.99) (width 0.25) (layer B.Cu) (net 88)) - (segment (start 129.508404 114.442789) (end 129.449194 114.44279) (width 0.25) (layer F.Cu) (net 88)) - (segment (start 129.508404 114.366588) (end 129.508404 114.442789) (width 0.25) (layer F.Cu) (net 88)) (segment (start 129.508404 114.366588) (end 126 117.874992) (width 0.25) (layer F.Cu) (net 88)) (segment (start 126 117.874992) (end 117.125008 117.874992) (width 0.25) (layer F.Cu) (net 88)) (via (at 112.5 124) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 88)) - (segment (start 113.631807 122.863389) (end 113.631807 122.868193) (width 0.25) (layer B.Cu) (net 88)) - (segment (start 113.631807 122.868193) (end 112.5 124) (width 0.25) (layer B.Cu) (net 88)) (segment (start 112.5 124) (end 112.5 124.3) (width 0.25) (layer F.Cu) (net 88)) (segment (start 112.753759 124.553759) (end 114.08474 124.553759) (width 0.25) (layer F.Cu) (net 88)) (segment (start 112.5 124.3) (end 112.753759 124.553759) (width 0.25) (layer F.Cu) (net 88)) @@ -10853,6 +10854,8 @@ (segment (start 144.22859 114.00259) (end 146.812 111.41918) (width 0.25) (layer F.Cu) (net 88)) (segment (start 135.69061 114.00259) (end 144.22859 114.00259) (width 0.25) (layer F.Cu) (net 88)) (segment (start 129.508404 114.366588) (end 135.326612 114.366588) (width 0.25) (layer F.Cu) (net 88)) + (segment (start 112.5 123.995196) (end 113.631807 122.863389) (width 0.25) (layer B.Cu) (net 88)) + (segment (start 112.5 124) (end 112.5 123.995196) (width 0.25) (layer B.Cu) (net 88)) (via (at 173.5 99.15) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) (via (at 143.4702 117.4498) (size 0.4) (drill 0.3) (layers F.Cu B.Cu) (net 89)) (segment (start 142.0248 117.4498) (end 141.9 117.325) (width 0.25) (layer F.Cu) (net 89)) @@ -11037,7 +11040,7 @@ (xy 215.240448 122.646508) (xy 214.443004 120.569096) (xy 187.241582 131.010743) (xy 188.020945 133.041054) (xy 187.30358 133.315) (xy 138.158838 133.315) (xy 138.096265 133.314123) (xy 138.058284 133.321126) (xy 138.019845 133.324912) (xy 137.959927 133.343088) (xy 93.864605 146.047335) (xy 93.520432 145.984758) (xy 93.243912 145.892584) (xy 93.08499 145.756366) (xy 82.933274 128.127044) - (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583074 116.011918) + (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583077 116.011913) (xy 88.59798 115.990873) (xy 88.615021 115.952706) (xy 88.618829 115.945648) (xy 88.62876 115.921935) (xy 88.639207 115.898536) (xy 88.641735 115.890952) (xy 88.657891 115.852374) (xy 88.663024 115.827087) (xy 88.84031 115.29523) (xy 88.855164 115.261034) (xy 88.868713 115.198522) (xy 88.882908 115.13609) (xy 88.883923 115.098817) (xy 88.948633 114.539922) (xy 88.950347 114.53427) @@ -11233,267 +11236,267 @@ (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) (xy 104.651604 131.677128) (xy 104.7368 131.616078) (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) (xy 104.978308 131.126349) (xy 104.973731 130.986567) (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.911452 130.783002) (xy 104.884253 130.722971) (xy 104.863839 130.694483) - (xy 103.694735 128.669537) (xy 103.82105 128.795852) (xy 103.855013 128.846681) (xy 103.971319 128.962987) (xy 104.108079 129.054367) - (xy 104.26004 129.117311) (xy 104.42136 129.1494) (xy 104.58584 129.1494) (xy 104.74716 129.117311) (xy 104.899121 129.054367) - (xy 105.035881 128.962987) (xy 105.152187 128.846681) (xy 105.243567 128.709921) (xy 105.306511 128.55796) (xy 105.30801 128.550422) - (xy 105.30801 129.730687) (xy 105.304334 129.76801) (xy 105.30801 129.805332) (xy 105.30801 129.805342) (xy 105.319007 129.916995) - (xy 105.354071 130.032587) (xy 105.362464 130.060256) (xy 105.433036 130.192286) (xy 105.462346 130.228) (xy 105.528009 130.308011) - (xy 105.557013 130.331814) (xy 107.517122 132.291924) (xy 107.560033 132.395521) (xy 107.651413 132.532281) (xy 107.767719 132.648587) - (xy 107.904479 132.739967) (xy 108.05644 132.802911) (xy 108.21776 132.835) (xy 108.38224 132.835) (xy 108.54356 132.802911) - (xy 108.695521 132.739967) (xy 108.832281 132.648587) (xy 108.948587 132.532281) (xy 109.039967 132.395521) (xy 109.102911 132.24356) - (xy 109.135 132.08224) (xy 109.135 131.91776) (xy 109.102911 131.75644) (xy 109.039967 131.604479) (xy 108.948587 131.467719) - (xy 108.832281 131.351413) (xy 108.695521 131.260033) (xy 108.591924 131.217122) (xy 106.82801 129.453209) (xy 106.82801 126.698472) - (xy 106.870921 126.594875) (xy 106.90301 126.433555) (xy 106.90301 126.269075) (xy 106.870921 126.107755) (xy 106.847881 126.052131) - (xy 106.93575 126.14) (xy 107.65 126.143072) (xy 107.714999 126.13667) (xy 107.714998 128.599949) (xy 107.711322 128.637272) - (xy 107.714998 128.674594) (xy 107.714998 128.674604) (xy 107.725995 128.786257) (xy 107.766155 128.918649) (xy 107.769452 128.929518) - (xy 107.840024 129.061548) (xy 107.879869 129.110098) (xy 107.934997 129.177273) (xy 107.964001 129.201076) (xy 110.137619 131.374695) - (xy 109.971493 131.419208) (xy 109.854426 131.463269) (xy 109.748204 131.529321) (xy 109.65691 131.614828) (xy 109.584051 131.716502) - (xy 109.532428 131.830436) (xy 109.504025 131.952253) (xy 109.499932 132.07727) (xy 109.520308 132.200683) (xy 110.037946 134.132535) - (xy 110.082007 134.249602) (xy 110.148059 134.355824) (xy 110.233566 134.447118) (xy 110.33524 134.519977) (xy 110.449174 134.5716) - (xy 110.570991 134.600003) (xy 110.696008 134.604096) (xy 110.819421 134.58372) (xy 111.996083 134.268434) (xy 114.027956 136.300308) - (xy 114.051754 136.329306) (xy 114.080752 136.353104) (xy 114.167478 136.424279) (xy 114.234305 136.459999) (xy 114.299508 136.494851) - (xy 114.442769 136.538308) (xy 114.554422 136.549305) (xy 114.554432 136.549305) (xy 114.591755 136.552981) (xy 114.629078 136.549305) - (xy 121.923373 136.549305) (xy 121.960695 136.552981) (xy 121.998017 136.549305) (xy 121.998028 136.549305) (xy 122.109681 136.538308) - (xy 122.252942 136.494851) (xy 122.384971 136.424279) (xy 122.500696 136.329306) (xy 122.524498 136.300303) (xy 123.041923 135.782878) - (xy 123.145521 135.739967) (xy 123.282281 135.648587) (xy 123.398587 135.532281) (xy 123.489967 135.395521) (xy 123.552911 135.24356) - (xy 123.585 135.08224) (xy 123.585 134.91776) (xy 123.552911 134.75644) (xy 123.489967 134.604479) (xy 123.398587 134.467719) - (xy 123.282281 134.351413) (xy 123.145521 134.260033) (xy 122.99356 134.197089) (xy 122.865488 134.171613) (xy 122.928117 134.108985) - (xy 122.967719 134.148587) (xy 123.104479 134.239967) (xy 123.25644 134.302911) (xy 123.41776 134.335) (xy 123.58224 134.335) - (xy 123.74356 134.302911) (xy 123.895521 134.239967) (xy 124.032281 134.148587) (xy 124.148587 134.032281) (xy 124.239967 133.895521) - (xy 124.302911 133.74356) (xy 124.332984 133.592374) (xy 125.96571 133.154886) (xy 126.082777 133.110825) (xy 126.188999 133.044773) - (xy 126.280293 132.959266) (xy 126.353152 132.857592) (xy 126.404775 132.743658) (xy 126.433178 132.621841) (xy 126.437271 132.496824) - (xy 126.416895 132.373411) (xy 126.118018 131.257987) (xy 126.711003 130.665002) (xy 126.740001 130.641204) (xy 126.834974 130.525479) - (xy 126.905546 130.39345) (xy 126.949003 130.250189) (xy 126.96 130.138536) (xy 126.96 130.138527) (xy 126.963676 130.101204) - (xy 126.96 130.063881) (xy 126.96 125.313072) (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) - (xy 128.554494 125.205537) (xy 128.651185 125.126185) (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) - (xy 128.91776 125.035) (xy 129.08224 125.035) (xy 129.24356 125.002911) (xy 129.347157 124.96) (xy 129.560199 124.96) - (xy 129.573701 124.973502) (xy 130.711928 126.11173) (xy 130.711928 127.28) (xy 130.724188 127.404482) (xy 130.760498 127.52418) - (xy 130.819463 127.634494) (xy 130.898815 127.731185) (xy 130.995506 127.810537) (xy 131.10582 127.869502) (xy 131.225518 127.905812) - (xy 131.35 127.918072) (xy 131.845674 127.918072) (xy 131.865026 127.954276) (xy 131.902142 127.999502) (xy 131.959999 128.070001) - (xy 131.989003 128.093804) (xy 134.961398 131.0662) (xy 134.437803 131.0662) (xy 133.407279 130.035677) (xy 133.364367 129.932079) - (xy 133.272987 129.795319) (xy 133.156681 129.679013) (xy 133.019921 129.587633) (xy 132.86796 129.524689) (xy 132.70664 129.4926) - (xy 132.54216 129.4926) (xy 132.38084 129.524689) (xy 132.228879 129.587633) (xy 132.092119 129.679013) (xy 131.975813 129.795319) - (xy 131.884433 129.932079) (xy 131.821489 130.08404) (xy 131.7894 130.24536) (xy 131.7894 130.40984) (xy 131.821489 130.57116) - (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) (xy 132.228879 131.067567) (xy 132.332477 131.110479) - (xy 133.559205 132.337208) (xy 133.582999 132.366201) (xy 133.611992 132.389995) (xy 133.611996 132.389999) (xy 133.674055 132.440929) - (xy 133.698724 132.461174) (xy 133.830753 132.531746) (xy 133.974014 132.575203) (xy 134.085667 132.5862) (xy 134.085676 132.5862) - (xy 134.122999 132.589876) (xy 134.160322 132.5862) (xy 142.970643 132.5862) (xy 143.07424 132.629111) (xy 143.23556 132.6612) - (xy 143.40004 132.6612) (xy 143.56136 132.629111) (xy 143.713321 132.566167) (xy 143.850081 132.474787) (xy 143.966387 132.358481) - (xy 144.057767 132.221721) (xy 144.120711 132.06976) (xy 144.1528 131.90844) (xy 144.1528 131.74396) (xy 144.120711 131.58264) - (xy 144.073474 131.4686) (xy 144.524078 131.4686) (xy 144.5614 131.472276) (xy 144.598722 131.4686) (xy 144.598733 131.4686) - (xy 144.710386 131.457603) (xy 144.853647 131.414146) (xy 144.985676 131.343574) (xy 145.101401 131.248601) (xy 145.125203 131.219598) - (xy 145.711002 130.6338) (xy 145.740001 130.610001) (xy 145.834974 130.494276) (xy 145.854326 130.458072) (xy 146.35 130.458072) - (xy 146.474482 130.445812) (xy 146.59418 130.409502) (xy 146.704494 130.350537) (xy 146.801185 130.271185) (xy 146.880537 130.174494) - (xy 146.912872 130.114) (xy 147.441043 130.114) (xy 147.54464 130.156911) (xy 147.70596 130.189) (xy 147.87044 130.189) - (xy 148.03176 130.156911) (xy 148.183721 130.093967) (xy 148.320481 130.002587) (xy 148.436787 129.886281) (xy 148.528167 129.749521) - (xy 148.591111 129.59756) (xy 148.6232 129.43624) (xy 148.6232 129.27176) (xy 148.591111 129.11044) (xy 148.528167 128.958479) - (xy 148.436787 128.821719) (xy 148.320481 128.705413) (xy 148.183721 128.614033) (xy 148.03176 128.551089) (xy 147.87044 128.519) - (xy 147.70596 128.519) (xy 147.54464 128.551089) (xy 147.441043 128.594) (xy 146.988072 128.594) (xy 146.988072 127.82) - (xy 146.975812 127.695518) (xy 146.939502 127.57582) (xy 146.880537 127.465506) (xy 146.801185 127.368815) (xy 146.704494 127.289463) - (xy 146.59418 127.230498) (xy 146.474482 127.194188) (xy 146.35 127.181928) (xy 145.230748 127.181928) (xy 145.362953 126.862756) - (xy 145.445 126.450279) (xy 145.445 126.029721) (xy 145.362953 125.617244) (xy 145.202012 125.228698) (xy 145.164985 125.173283) - (xy 145.330779 125.104609) (xy 145.590379 124.93115) (xy 145.81115 124.710379) (xy 145.984609 124.450779) (xy 146.104089 124.162327) - (xy 146.165 123.856109) (xy 146.165 123.543891) (xy 146.104089 123.237673) (xy 145.984609 122.949221) (xy 145.81115 122.689621) - (xy 145.590379 122.46885) (xy 145.330779 122.295391) (xy 145.042327 122.175911) (xy 144.736109 122.115) (xy 144.423891 122.115) - (xy 144.117673 122.175911) (xy 144.023303 122.215) (xy 143.85374 122.215) (xy 143.566842 122.272068) (xy 143.296589 122.38401) - (xy 143.053368 122.546525) (xy 142.846525 122.753368) (xy 142.68401 122.996589) (xy 142.572068 123.266842) (xy 142.515 123.55374) - (xy 142.515 123.84626) (xy 142.572068 124.133158) (xy 142.607988 124.219876) (xy 142.298698 124.347988) (xy 142.076252 124.496622) - (xy 142.081817 124.483186) (xy 142.185 123.964449) (xy 142.185 123.435551) (xy 142.081817 122.916814) (xy 141.879417 122.428175) - (xy 141.585576 121.988412) (xy 141.261364 121.6642) (xy 145.299401 121.6642) (xy 153.500204 129.865004) (xy 153.524002 129.894002) - (xy 153.639727 129.988975) (xy 153.771756 130.059547) (xy 153.915017 130.103004) (xy 154.02667 130.114001) (xy 154.026679 130.114001) - (xy 154.064002 130.117677) (xy 154.101325 130.114001) (xy 169.757177 130.114001) (xy 169.794499 130.117677) (xy 169.831821 130.114001) - (xy 169.831832 130.114001) (xy 169.943485 130.103004) (xy 170.086746 130.059547) (xy 170.218775 129.988975) (xy 170.3345 129.894002) - (xy 170.358302 129.864999) (xy 170.6245 129.598801) (xy 173.159701 132.134003) (xy 173.183499 132.163001) (xy 173.212497 132.186799) - (xy 173.299223 132.257974) (xy 173.431253 132.328546) (xy 173.574514 132.372003) (xy 173.686167 132.383) (xy 173.686176 132.383) - (xy 173.723499 132.386676) (xy 173.760822 132.383) (xy 177.717843 132.383) (xy 177.82144 132.425911) (xy 177.98276 132.458) - (xy 178.14724 132.458) (xy 178.30856 132.425911) (xy 178.460521 132.362967) (xy 178.597281 132.271587) (xy 178.713587 132.155281) - (xy 178.804967 132.018521) (xy 178.867911 131.86656) (xy 178.891494 131.748) (xy 181.194678 131.748) (xy 181.232 131.751676) - (xy 181.269322 131.748) (xy 181.269333 131.748) (xy 181.380986 131.737003) (xy 181.524247 131.693546) (xy 181.656276 131.622974) - (xy 181.772001 131.528001) (xy 181.795804 131.498997) (xy 182.736729 130.558072) (xy 184.45 130.558072) (xy 184.574482 130.545812) - (xy 184.69418 130.509502) (xy 184.804494 130.450537) (xy 184.901185 130.371185) (xy 184.980537 130.274494) (xy 185.039502 130.16418) - (xy 185.075812 130.044482) (xy 185.088072 129.92) (xy 185.088072 128.343229) (xy 194.671302 118.76) (xy 202.891678 118.76) - (xy 202.929 118.763676) (xy 202.966322 118.76) (xy 202.966333 118.76) (xy 203.077986 118.749003) (xy 203.221247 118.705546) - (xy 203.353276 118.634974) (xy 203.469001 118.540001) (xy 203.492803 118.510998) (xy 204.743813 117.25999) (xy 209.652843 117.25999) - (xy 209.75644 117.302901) (xy 209.91776 117.33499) (xy 210.08224 117.33499) (xy 210.24356 117.302901) (xy 210.395521 117.239957) - (xy 210.402955 117.23499) (xy 221.07053 117.23499) (xy 221.107852 117.238666) (xy 221.145174 117.23499) (xy 221.145185 117.23499) - (xy 221.256838 117.223993) (xy 221.400099 117.180536) (xy 221.532128 117.109964) (xy 221.647853 117.014991) (xy 221.671656 116.985987) - (xy 221.960997 116.696646) (xy 221.990001 116.672843) (xy 222.084974 116.557118) (xy 222.155546 116.425089) (xy 222.199003 116.281828) - (xy 222.201343 116.258072) (xy 222.6 116.258072) (xy 222.724482 116.245812) (xy 222.84418 116.209502) (xy 222.954494 116.150537) - (xy 223.051185 116.071185) (xy 223.130537 115.974494) (xy 223.189502 115.86418) (xy 223.225812 115.744482) (xy 223.238072 115.62) - (xy 223.238072 114.05673) (xy 223.361004 113.933798) (xy 223.390001 113.910001) (xy 223.416332 113.877917) (xy 223.484974 113.794277) - (xy 223.555546 113.662247) (xy 223.566009 113.627754) (xy 223.599003 113.518986) (xy 223.61 113.407333) (xy 223.61 113.407323) - (xy 223.613676 113.37) (xy 223.61 113.332677) (xy 223.61 107.387325) (xy 223.613676 107.35) (xy 223.61 107.312675) - (xy 223.61 107.312667) (xy 223.599003 107.201014) (xy 223.555546 107.057753) (xy 223.484974 106.925724) (xy 223.390001 106.809999) - (xy 223.361003 106.786201) (xy 222.035009 105.460208) (xy 222.035009 101.275922) (xy 222.038685 101.238599) (xy 222.035009 101.201276) - (xy 222.035009 101.201266) (xy 222.024012 101.089613) (xy 221.980555 100.946352) (xy 221.909983 100.814323) (xy 221.81501 100.698598) - (xy 221.786011 100.674799) (xy 221.51 100.398789) (xy 221.51 98.097157) (xy 221.552911 97.99356) (xy 221.585 97.83224) - (xy 221.585 97.66776) (xy 221.552911 97.50644) (xy 221.51 97.402843) (xy 221.51 97.258072) (xy 222.55 97.258072) - (xy 222.674482 97.245812) (xy 222.79418 97.209502) (xy 222.904494 97.150537) (xy 223.001185 97.071185) (xy 223.080537 96.974494) - (xy 223.139502 96.86418) (xy 223.175812 96.744482) (xy 223.188072 96.62) (xy 223.188072 94.62) (xy 223.175812 94.495518) - (xy 223.139502 94.37582) (xy 223.080537 94.265506) (xy 223.001185 94.168815) (xy 222.904494 94.089463) (xy 222.815001 94.041627) - (xy 222.815001 80.017314) (xy 222.818677 79.979991) (xy 222.815001 79.942668) (xy 222.815001 79.942658) (xy 222.804004 79.831005) - (xy 222.760547 79.687744) (xy 222.689975 79.555715) (xy 222.595002 79.43999) (xy 222.566004 79.416192) (xy 221.332879 78.183068) - (xy 221.31 78.127833) (xy 221.31 78.058072) (xy 222.55 78.058072) (xy 222.674482 78.045812) (xy 222.79418 78.009502) - (xy 222.904494 77.950537) (xy 223.001185 77.871185) (xy 223.080537 77.774494) (xy 223.139502 77.66418) (xy 223.175812 77.544482) - (xy 223.188072 77.42) (xy 223.188072 75.42) (xy 223.175812 75.295518) (xy 223.139502 75.17582) (xy 223.080537 75.065506) - (xy 223.001185 74.968815) (xy 222.904494 74.889463) (xy 222.79418 74.830498) (xy 222.674482 74.794188) (xy 222.55 74.781928) - (xy 222.16 74.781928) (xy 222.16 72.881803) (xy 222.566005 72.475799) (xy 222.595002 72.452002) (xy 222.689975 72.336277) - (xy 222.760547 72.204248) (xy 222.804004 72.060987) (xy 222.815001 71.949334) (xy 222.815001 71.949325) (xy 222.818677 71.912002) - (xy 222.815001 71.874679) (xy 222.815001 61.342334) (xy 222.818678 61.305001) (xy 222.804004 61.156015) (xy 222.760547 61.012754) - (xy 222.689975 60.880725) (xy 222.648794 60.830546) (xy 222.595002 60.765) (xy 222.566004 60.741202) (xy 221.282879 59.458078) - (xy 221.26 59.402843) (xy 221.26 59.158072) (xy 222.65 59.158072) (xy 222.774482 59.145812) (xy 222.89418 59.109502) - (xy 223.004494 59.050537) (xy 223.101185 58.971185) (xy 223.180537 58.874494) (xy 223.239502 58.76418) (xy 223.275812 58.644482) - (xy 223.288072 58.52) (xy 223.288072 56.52) (xy 223.275812 56.395518) (xy 223.239502 56.27582) (xy 223.180537 56.165506) - (xy 223.101185 56.068815) (xy 223.004494 55.989463) (xy 222.89418 55.930498) (xy 222.774482 55.894188) (xy 222.65 55.881928) - (xy 221.530748 55.881928) (xy 221.662953 55.562756) (xy 221.745 55.150279) (xy 221.745 54.729721) (xy 221.662953 54.317244) - (xy 221.502012 53.928698) (xy 221.464985 53.873283) (xy 221.630779 53.804609) (xy 221.890379 53.63115) (xy 222.11115 53.410379) - (xy 222.284609 53.150779) (xy 222.404089 52.862327) (xy 222.465 52.556109) (xy 222.465 52.243891) (xy 222.404089 51.937673) - (xy 222.284609 51.649221) (xy 222.11115 51.389621) (xy 221.890379 51.16885) (xy 221.630779 50.995391) (xy 221.342327 50.875911) - (xy 221.036109 50.815) (xy 220.723891 50.815) (xy 220.417673 50.875911) (xy 220.323303 50.915) (xy 220.15374 50.915) - (xy 219.866842 50.972068) (xy 219.596589 51.08401) (xy 219.353368 51.246525) (xy 219.146525 51.453368) (xy 218.98401 51.696589) - (xy 218.872068 51.966842) (xy 218.815 52.25374) (xy 218.815 52.54626) (xy 218.872068 52.833158) (xy 218.907988 52.919876) - (xy 218.598698 53.047988) (xy 218.376252 53.196622) (xy 218.381817 53.183186) (xy 218.485 52.664449) (xy 218.485 52.135551) - (xy 218.381817 51.616814) (xy 218.179417 51.128175) (xy 217.885576 50.688412) (xy 217.511588 50.314424) (xy 217.071825 50.020583) - (xy 216.687522 49.8614) (xy 217.415123 49.8614) (xy 217.45 49.864835) (xy 217.484877 49.8614) (xy 217.589184 49.851127) - (xy 217.72302 49.810528) (xy 217.846363 49.7446) (xy 217.954475 49.655875) (xy 218.0432 49.547763) (xy 218.109128 49.42442) - (xy 218.149727 49.290584) (xy 218.163435 49.1514) (xy 218.16 49.116523) (xy 218.16 47.628) (xy 218.327 47.628) - (xy 218.327 47.648) (xy 218.347 47.648) (xy 218.347 47.902) (xy 218.327 47.902) (xy 218.327 48.75125) - (xy 218.48575 48.91) (xy 219 48.913072) (xy 219.124482 48.900812) (xy 219.24418 48.864502) (xy 219.354494 48.805537) - (xy 219.451185 48.726185) (xy 219.530537 48.629494) (xy 219.589502 48.51918) (xy 219.625812 48.399482) (xy 219.638072 48.275) - (xy 219.635 48.06075) (xy 219.476252 47.902002) (xy 219.635 47.902002) (xy 219.635 47.804614) (xy 219.64356 47.802911) - (xy 219.795521 47.739967) (xy 219.932281 47.648587) (xy 220.048587 47.532281) (xy 220.139967 47.395521) (xy 220.202911 47.24356) - (xy 220.235 47.08224) (xy 220.235 46.91776) (xy 220.202911 46.75644) (xy 220.139967 46.604479) (xy 220.048587 46.467719) - (xy 219.932281 46.351413) (xy 219.795521 46.260033) (xy 219.691923 46.217122) (xy 219.638072 46.16327) (xy 219.638072 45.525) - (xy 219.625812 45.400518) (xy 219.589502 45.28082) (xy 219.530537 45.170506) (xy 219.451185 45.073815) (xy 219.354494 44.994463) - (xy 219.24418 44.935498) (xy 219.16 44.909962) (xy 219.16 44.747157) (xy 219.202911 44.64356) (xy 219.235 44.48224) - (xy 219.235 44.31776) (xy 219.202911 44.15644) (xy 219.139967 44.004479) (xy 219.048587 43.867719) (xy 218.932281 43.751413) - (xy 218.795521 43.660033) (xy 218.64356 43.597089) (xy 218.48224 43.565) (xy 218.31776 43.565) (xy 218.15644 43.597089) - (xy 218.004479 43.660033) (xy 217.867719 43.751413) (xy 217.751413 43.867719) (xy 217.67743 43.978442) (xy 217.589184 43.951673) - (xy 217.484877 43.9414) (xy 217.45 43.937965) (xy 217.415123 43.9414) (xy 213.984877 43.9414) (xy 213.95 43.937965) - (xy 213.915123 43.9414) (xy 213.810816 43.951673) (xy 213.67698 43.992272) (xy 213.553637 44.0582) (xy 213.445525 44.146925) - (xy 213.3568 44.255037) (xy 213.290872 44.37838) (xy 213.250273 44.512216) (xy 213.236565 44.6514) (xy 213.240001 44.686287) - (xy 213.240001 44.886928) (xy 212.6 44.886928) (xy 212.475518 44.899188) (xy 212.35582 44.935498) (xy 212.245506 44.994463) - (xy 212.148815 45.073815) (xy 212.094499 45.14) (xy 211.818466 45.14) (xy 211.788641 45.137063) (xy 210.430332 43.778754) - (xy 210.402617 43.744983) (xy 210.267859 43.634389) (xy 210.114113 43.552211) (xy 209.94729 43.501605) (xy 209.817277 43.4888) - (xy 209.817269 43.4888) (xy 209.7738 43.484519) (xy 209.730331 43.4888) (xy 206.365023 43.4888) (xy 206.239249 43.385579) - (xy 206.085503 43.303401) (xy 205.91868 43.252795) (xy 205.788667 43.23999) (xy 205.788659 43.23999) (xy 205.74519 43.235709) - (xy 205.701721 43.23999) (xy 194.668479 43.23999) (xy 194.62501 43.235709) (xy 194.581541 43.23999) (xy 194.581533 43.23999) - (xy 194.45152 43.252795) (xy 194.284697 43.303401) (xy 194.130951 43.385579) (xy 193.996193 43.496173) (xy 193.968476 43.529946) - (xy 193.704956 43.793466) (xy 193.671183 43.821183) (xy 193.645482 43.8525) (xy 193.379079 43.8525) (xy 188.334046 38.807468) - (xy 188.181533 38.654955) (xy 188.153816 38.621182) (xy 188.019058 38.510588) (xy 187.865312 38.42841) (xy 187.698489 38.377804) - (xy 187.568476 38.364999) (xy 187.568468 38.364999) (xy 187.524999 38.360718) (xy 187.48153 38.364999) (xy 175.75099 38.364999) - (xy 175.707524 38.360718) (xy 175.664058 38.364999) (xy 175.664048 38.364999) (xy 175.534035 38.377804) (xy 175.367212 38.42841) - (xy 175.213466 38.510588) (xy 175.078708 38.621182) (xy 175.050991 38.654955) (xy 174.952736 38.75321) (xy 169.314789 38.75321) - (xy 168.345046 37.783468) (xy 168.244059 37.70059) (xy 168.090313 37.618412) (xy 168.075496 37.613917) (xy 166.482013 36.020435) - (xy 166.454296 35.986662) (xy 166.319538 35.876068) (xy 166.165792 35.79389) (xy 165.998969 35.743284) (xy 165.868956 35.730479) - (xy 165.868948 35.730479) (xy 165.825479 35.726198) (xy 165.78201 35.730479) (xy 156.517987 35.730479) (xy 156.47452 35.726198) - (xy 156.431054 35.730479) (xy 156.431044 35.730479) (xy 156.301031 35.743284) (xy 156.134208 35.79389) (xy 155.980462 35.876068) - (xy 155.845704 35.986662) (xy 155.817987 36.020435) (xy 155.404952 36.43347) (xy 155.371184 36.461183) (xy 155.260589 36.595941) - (xy 155.178411 36.749687) (xy 155.127805 36.91651) (xy 155.115 37.046523) (xy 155.115 37.046531) (xy 155.110719 37.09) - (xy 155.115 37.133469) (xy 155.115 37.557317) (xy 155.045506 37.594463) (xy 154.948815 37.673815) (xy 154.869463 37.770506) - (xy 154.818954 37.865) (xy 153.825476 37.865) (xy 153.782 37.860718) (xy 153.738523 37.865) (xy 137.368479 37.865) - (xy 137.32501 37.860719) (xy 137.281541 37.865) (xy 137.281533 37.865) (xy 137.15152 37.877805) (xy 136.984697 37.928411) - (xy 136.857903 37.996183) (xy 136.830951 38.010589) (xy 136.729963 38.093468) (xy 136.729961 38.09347) (xy 136.696193 38.121183) - (xy 136.66848 38.154951) (xy 134.904958 39.918474) (xy 134.904953 39.918478) (xy 134.904951 39.91848) (xy 134.871183 39.946193) - (xy 134.84347 39.979961) (xy 134.308432 40.515) (xy 127.643465 40.515) (xy 127.599999 40.510719) (xy 127.556533 40.515) - (xy 118.643465 40.515) (xy 118.599999 40.510719) (xy 118.556533 40.515) (xy 118.556523 40.515) (xy 118.42651 40.527805) - (xy 118.259687 40.578411) (xy 118.105941 40.660589) (xy 118.097828 40.667247) (xy 118.004953 40.743468) (xy 118.004951 40.74347) - (xy 117.971183 40.771183) (xy 117.94347 40.804951) (xy 116.833423 41.914999) (xy 116.131464 41.914999) (xy 116.087998 41.910718) - (xy 116.044532 41.914999) (xy 116.044522 41.914999) (xy 115.914509 41.927804) (xy 115.747686 41.97841) (xy 115.59394 42.060588) - (xy 115.459182 42.171182) (xy 115.431465 42.204955) (xy 115.154955 42.481465) (xy 115.121182 42.509182) (xy 115.010588 42.643941) - (xy 114.92841 42.797687) (xy 114.896094 42.904217) (xy 114.877804 42.964509) (xy 114.876211 42.980685) (xy 114.864999 43.094523) - (xy 114.864999 43.09453) (xy 114.860718 43.137999) (xy 114.864999 43.181469) (xy 114.864999 43.615) (xy 113.793465 43.615) - (xy 113.749999 43.610719) (xy 113.706533 43.615) (xy 113.706523 43.615) (xy 113.57651 43.627805) (xy 113.409687 43.678411) - (xy 113.255941 43.760589) (xy 113.244474 43.77) (xy 113.154953 43.843468) (xy 113.154951 43.84347) (xy 113.121183 43.871183) - (xy 113.09347 43.904951) (xy 111.129958 45.868464) (xy 111.129953 45.868468) (xy 110.015389 46.983032) (xy 109.986451 46.902722) - (xy 109.924471 46.786765) (xy 109.68438 46.719785) (xy 108.89842 47.505745) (xy 108.912563 47.519888) (xy 108.732958 47.699493) - (xy 108.718815 47.68535) (xy 108.704673 47.699493) (xy 108.525068 47.519888) (xy 108.53921 47.505745) (xy 108.525068 47.491603) - (xy 108.704673 47.311998) (xy 108.718815 47.32614) (xy 109.504775 46.54018) (xy 109.437795 46.300089) (xy 109.302055 46.23626) - (xy 109.380542 46.20375) (xy 109.60935 46.050865) (xy 109.803935 45.85628) (xy 109.95682 45.627472) (xy 110.062129 45.373235) - (xy 110.115815 45.103337) (xy 110.115815 44.828153) (xy 110.062129 44.558255) (xy 109.95682 44.304018) (xy 109.803935 44.07521) - (xy 109.60935 43.880625) (xy 109.380542 43.72774) (xy 109.3033 43.695745) (xy 109.380542 43.66375) (xy 109.60935 43.510865) - (xy 109.803935 43.31628) (xy 109.95682 43.087472) (xy 110.062129 42.833235) (xy 110.115815 42.563337) (xy 110.115815 42.288153) - (xy 110.062129 42.018255) (xy 109.95682 41.764018) (xy 109.803935 41.53521) (xy 109.60935 41.340625) (xy 109.380542 41.18774) - (xy 109.126305 41.082431) (xy 108.856407 41.028745) (xy 108.804337 41.028745) (xy 108.763314 40.82251) (xy 108.658005 40.568273) - (xy 108.50512 40.339465) (xy 108.310535 40.14488) (xy 108.081727 39.991995) (xy 107.82749 39.886686) (xy 107.557592 39.833) - (xy 107.282408 39.833) (xy 107.01251 39.886686) (xy 106.758273 39.991995) (xy 106.529465 40.14488) (xy 106.33488 40.339465) - (xy 106.181995 40.568273) (xy 106.076686 40.82251) (xy 106.071225 40.849967) (xy 105.991928 40.817121) (xy 105.89381 40.719003) - (xy 105.870007 40.689999) (xy 105.754282 40.595026) (xy 105.622253 40.524454) (xy 105.478992 40.480997) (xy 105.367339 40.47) - (xy 105.367328 40.47) (xy 105.330006 40.466324) (xy 105.292684 40.47) (xy 93.352341 40.47) (xy 93.26512 40.339465) - (xy 93.070535 40.14488) (xy 92.841727 39.991995) (xy 92.58749 39.886686) (xy 92.317592 39.833) (xy 92.042408 39.833) - (xy 91.77251 39.886686) (xy 91.518273 39.991995) (xy 91.289465 40.14488) (xy 91.09488 40.339465) (xy 90.941995 40.568273) - (xy 90.836686 40.82251) (xy 90.783 41.092408) (xy 90.783 41.367592) (xy 90.836686 41.63749) (xy 90.941995 41.891727) - (xy 91.09488 42.120535) (xy 91.289465 42.31512) (xy 91.518273 42.468005) (xy 91.595515 42.5) (xy 91.518273 42.531995) - (xy 91.289465 42.68488) (xy 91.09488 42.879465) (xy 90.941995 43.108273) (xy 90.836686 43.36251) (xy 90.783 43.632408) - (xy 90.783 43.907592) (xy 90.836686 44.17749) (xy 90.941995 44.431727) (xy 91.09488 44.660535) (xy 91.289465 44.85512) - (xy 91.518273 45.008005) (xy 91.589943 45.037692) (xy 91.576977 45.042364) (xy 91.46102 45.104344) (xy 91.39404 45.344435) - (xy 92.18 46.130395) (xy 92.96596 45.344435) (xy 92.956048 45.308907) (xy 93.29921 44.965745) (xy 93.285068 44.951603) - (xy 93.464673 44.771998) (xy 93.478815 44.78614) (xy 93.492958 44.771998) (xy 93.672563 44.951603) (xy 93.65842 44.965745) - (xy 94.44438 45.751705) (xy 94.684471 45.684725) (xy 94.801571 45.435697) (xy 94.867838 45.16861) (xy 94.875429 45.006688) - (xy 95.01776 45.035) (xy 95.18224 45.035) (xy 95.34356 45.002911) (xy 95.495521 44.939967) (xy 95.632281 44.848587) - (xy 95.748587 44.732281) (xy 95.839967 44.595521) (xy 95.867107 44.53) (xy 105.049889 44.53) (xy 105.051413 44.532281) - (xy 105.167719 44.648587) (xy 105.304479 44.739967) (xy 105.45644 44.802911) (xy 105.61776 44.835) (xy 105.78224 44.835) - (xy 105.94356 44.802911) (xy 106.095521 44.739967) (xy 106.232281 44.648587) (xy 106.348587 44.532281) (xy 106.351882 44.52735) - (xy 106.454435 44.55596) (xy 107.240395 43.77) (xy 107.226253 43.755858) (xy 107.405858 43.576253) (xy 107.42 43.590395) - (xy 107.434143 43.576253) (xy 107.613748 43.755858) (xy 107.599605 43.77) (xy 107.613748 43.784143) (xy 107.434143 43.963748) - (xy 107.42 43.949605) (xy 106.63404 44.735565) (xy 106.70102 44.975656) (xy 106.83676 45.039485) (xy 106.758273 45.071995) - (xy 106.529465 45.22488) (xy 106.33488 45.419465) (xy 106.321159 45.44) (xy 105.737322 45.44) (xy 105.699999 45.436324) - (xy 105.662676 45.44) (xy 105.662667 45.44) (xy 105.551014 45.450997) (xy 105.407753 45.494454) (xy 105.275724 45.565026) - (xy 105.159999 45.659999) (xy 105.136201 45.688997) (xy 104.079454 46.745745) (xy 94.651156 46.745745) (xy 94.563935 46.61521) - (xy 94.36935 46.420625) (xy 94.140542 46.26774) (xy 94.068872 46.238053) (xy 94.081838 46.233381) (xy 94.197795 46.171401) - (xy 94.264775 45.93131) (xy 93.478815 45.14535) (xy 92.692855 45.93131) (xy 92.702767 45.966838) (xy 92.359605 46.31) - (xy 92.373748 46.324143) (xy 92.194143 46.503748) (xy 92.18 46.489605) (xy 91.39404 47.275565) (xy 91.46102 47.515656) - (xy 91.591644 47.577079) (xy 91.576977 47.582364) (xy 91.46102 47.644344) (xy 91.39404 47.884435) (xy 92.18 48.670395) - (xy 92.194143 48.656253) (xy 92.373748 48.835858) (xy 92.359605 48.85) (xy 92.373748 48.864143) (xy 92.194143 49.043748) - (xy 92.18 49.029605) (xy 91.39404 49.815565) (xy 91.46102 50.055656) (xy 91.59676 50.119485) (xy 91.518273 50.151995) - (xy 91.289465 50.30488) (xy 91.09488 50.499465) (xy 90.941995 50.728273) (xy 90.836686 50.98251) (xy 90.783 51.252408) - (xy 90.783 51.527592) (xy 90.836686 51.79749) (xy 90.941995 52.051727) (xy 91.09488 52.280535) (xy 91.289465 52.47512) - (xy 91.518273 52.628005) (xy 91.595515 52.66) (xy 91.518273 52.691995) (xy 91.289465 52.84488) (xy 91.09488 53.039465) - (xy 90.941995 53.268273) (xy 90.836686 53.52251) (xy 90.783 53.792408) (xy 90.783 54.067592) (xy 90.836686 54.33749) - (xy 90.941995 54.591727) (xy 91.09488 54.820535) (xy 91.289465 55.01512) (xy 91.518273 55.168005) (xy 91.595515 55.2) - (xy 91.518273 55.231995) (xy 91.289465 55.38488) (xy 91.09488 55.579465) (xy 90.941995 55.808273) (xy 90.836686 56.06251) - (xy 90.783 56.332408) (xy 90.783 56.607592) (xy 90.836686 56.87749) (xy 90.941995 57.131727) (xy 91.09488 57.360535) - (xy 91.289465 57.55512) (xy 91.518273 57.708005) (xy 91.595515 57.74) (xy 91.518273 57.771995) (xy 91.289465 57.92488) - (xy 91.09488 58.119465) (xy 90.941995 58.348273) (xy 90.836686 58.60251) (xy 90.783 58.872408) (xy 90.783 59.147592) - (xy 90.836686 59.41749) (xy 90.941995 59.671727) (xy 91.09488 59.900535) (xy 91.289465 60.09512) (xy 91.518273 60.248005) - (xy 91.595515 60.28) (xy 91.518273 60.311995) (xy 91.289465 60.46488) (xy 91.09488 60.659465) (xy 90.941995 60.888273) - (xy 90.836686 61.14251) (xy 90.783 61.412408) (xy 90.783 61.687592) (xy 90.836686 61.95749) (xy 90.941995 62.211727) - (xy 91.09488 62.440535) (xy 91.289465 62.63512) (xy 91.518273 62.788005) (xy 91.595515 62.82) (xy 91.518273 62.851995) - (xy 91.289465 63.00488) (xy 91.09488 63.199465) (xy 90.941995 63.428273) (xy 90.836686 63.68251) (xy 90.783 63.952408) - (xy 90.783 64.227592) (xy 90.836686 64.49749) (xy 90.941995 64.751727) (xy 91.09488 64.980535) (xy 91.289465 65.17512) - (xy 91.518273 65.328005) (xy 91.595515 65.36) (xy 91.518273 65.391995) (xy 91.289465 65.54488) (xy 91.09488 65.739465) - (xy 90.941995 65.968273) (xy 90.836686 66.22251) (xy 90.783 66.492408) (xy 90.783 66.767592) (xy 90.836686 67.03749) - (xy 90.941995 67.291727) (xy 91.09488 67.520535) (xy 91.289465 67.71512) (xy 91.518273 67.868005) (xy 91.595515 67.9) - (xy 91.518273 67.931995) (xy 91.289465 68.08488) (xy 91.09488 68.279465) (xy 90.941995 68.508273) (xy 90.836686 68.76251) - (xy 90.783 69.032408) (xy 90.783 69.307592) (xy 90.836686 69.57749) (xy 90.941995 69.831727) (xy 91.09488 70.060535) - (xy 91.289465 70.25512) (xy 91.518273 70.408005) (xy 91.77251 70.513314) (xy 92.042408 70.567) (xy 92.094478 70.567) - (xy 92.135501 70.773235) (xy 92.24081 71.027472) (xy 92.393695 71.25628) (xy 92.58828 71.450865) (xy 92.817088 71.60375) - (xy 93.071325 71.709059) (xy 93.341223 71.762745) (xy 93.616407 71.762745) (xy 93.886305 71.709059) (xy 94.04 71.645396) - (xy 94.040001 73.544048) (xy 93.4285 73.544048) (xy 93.304018 73.556308) (xy 93.18432 73.592618) (xy 93.074006 73.651583) - (xy 92.977315 73.730935) (xy 92.897963 73.827626) (xy 92.838998 73.93794) (xy 92.802688 74.057638) (xy 92.790428 74.18212) - (xy 92.790428 74.81712) (xy 92.802688 74.941602) (xy 92.820403 75) (xy 92.802688 75.058398) (xy 92.790428 75.18288) - (xy 92.790428 75.81788) (xy 92.802688 75.942362) (xy 92.838998 76.06206) (xy 92.897963 76.172374) (xy 92.977315 76.269065) - (xy 93.074006 76.348417) (xy 93.18432 76.407382) (xy 93.24 76.424272) (xy 93.240001 80.935197) (xy 92.36401 81.811189) - (xy 92.335009 81.834989) (xy 92.311211 81.863987) (xy 92.065995 82.109203) (xy 91.991111 82.086487) (xy 91.77295 82.065) - (xy 90.974885 82.065) (xy 91.042252 82.019987) (xy 91.269987 81.792252) (xy 91.448918 81.524463) (xy 91.572168 81.226912) - (xy 91.635 80.911033) (xy 91.635 80.588967) (xy 91.572168 80.273088) (xy 91.448918 79.975537) (xy 91.269987 79.707748) - (xy 91.042252 79.480013) (xy 90.774463 79.301082) (xy 90.476912 79.177832) (xy 90.161033 79.115) (xy 89.838967 79.115) - (xy 89.523088 79.177832) (xy 89.225537 79.301082) (xy 88.959613 79.478767) (xy 88.959539 75.470069) (xy 89.044193 75.385415) - (xy 89.139956 75.649814) (xy 89.429571 75.790704) (xy 89.741108 75.872384) (xy 90.062595 75.891718) (xy 90.381675 75.847961) - (xy 90.686088 75.742795) (xy 90.860044 75.649814) (xy 90.955808 75.385413) (xy 90 74.429605) (xy 89.985858 74.443748) - (xy 89.806253 74.264143) (xy 89.820395 74.25) (xy 90.179605 74.25) (xy 91.135413 75.205808) (xy 91.399814 75.110044) - (xy 91.540704 74.820429) (xy 91.622384 74.508892) (xy 91.641718 74.187405) (xy 91.597961 73.868325) (xy 91.492795 73.563912) - (xy 91.399814 73.389956) (xy 91.135413 73.294192) (xy 90.179605 74.25) (xy 89.820395 74.25) (xy 89.806253 74.235858) - (xy 89.985858 74.056253) (xy 90 74.070395) (xy 90.955808 73.114587) (xy 90.860044 72.850186) (xy 90.570429 72.709296) - (xy 90.258892 72.627616) (xy 89.937405 72.608282) (xy 89.618325 72.652039) (xy 89.313912 72.757205) (xy 89.139956 72.850186) - (xy 89.044193 73.114585) (xy 88.959493 73.029885) (xy 88.959049 48.922017) (xy 90.77809 48.922017) (xy 90.819078 49.194133) - (xy 90.912364 49.453023) (xy 90.974344 49.56898) (xy 91.214435 49.63596) (xy 92.000395 48.85) (xy 91.214435 48.06404) - (xy 90.974344 48.13102) (xy 90.857244 48.380048) (xy 90.790977 48.647135) (xy 90.77809 48.922017) (xy 88.959049 48.922017) - (xy 88.959003 46.382017) (xy 90.77809 46.382017) (xy 90.819078 46.654133) (xy 90.912364 46.913023) (xy 90.974344 47.02898) - (xy 91.214435 47.09596) (xy 92.000395 46.31) (xy 91.214435 45.52404) (xy 90.974344 45.59102) (xy 90.857244 45.840048) - (xy 90.790977 46.107135) (xy 90.77809 46.382017) (xy 88.959003 46.382017) (xy 88.958857 38.511863) (xy 88.971894 38.382509) - (xy 88.998593 38.296493) (xy 89.041067 38.218238) (xy 89.097851 38.149414) (xy 89.16667 38.092633) (xy 89.244936 38.05015) - (xy 89.33096 38.023445) (xy 89.473606 38.009063) (xy 149.013379 35.685) (xy 170.896299 35.685) + (xy 103.814368 128.876747) (xy 103.908553 128.970932) (xy 104.009541 129.053811) (xy 104.163286 129.135989) (xy 104.33011 129.186595) + (xy 104.5036 129.203681) (xy 104.67709 129.186595) (xy 104.843913 129.135989) (xy 104.997659 129.053811) (xy 105.132417 128.943217) + (xy 105.243011 128.808459) (xy 105.30801 128.686852) (xy 105.30801 129.730687) (xy 105.304334 129.76801) (xy 105.30801 129.805332) + (xy 105.30801 129.805342) (xy 105.319007 129.916995) (xy 105.354071 130.032587) (xy 105.362464 130.060256) (xy 105.433036 130.192286) + (xy 105.462346 130.228) (xy 105.528009 130.308011) (xy 105.557013 130.331814) (xy 107.517122 132.291924) (xy 107.560033 132.395521) + (xy 107.651413 132.532281) (xy 107.767719 132.648587) (xy 107.904479 132.739967) (xy 108.05644 132.802911) (xy 108.21776 132.835) + (xy 108.38224 132.835) (xy 108.54356 132.802911) (xy 108.695521 132.739967) (xy 108.832281 132.648587) (xy 108.948587 132.532281) + (xy 109.039967 132.395521) (xy 109.102911 132.24356) (xy 109.135 132.08224) (xy 109.135 131.91776) (xy 109.102911 131.75644) + (xy 109.039967 131.604479) (xy 108.948587 131.467719) (xy 108.832281 131.351413) (xy 108.695521 131.260033) (xy 108.591924 131.217122) + (xy 106.82801 129.453209) (xy 106.82801 126.698472) (xy 106.870921 126.594875) (xy 106.90301 126.433555) (xy 106.90301 126.269075) + (xy 106.870921 126.107755) (xy 106.847881 126.052131) (xy 106.93575 126.14) (xy 107.65 126.143072) (xy 107.714999 126.13667) + (xy 107.714998 128.599949) (xy 107.711322 128.637272) (xy 107.714998 128.674594) (xy 107.714998 128.674604) (xy 107.725995 128.786257) + (xy 107.766155 128.918649) (xy 107.769452 128.929518) (xy 107.840024 129.061548) (xy 107.879869 129.110098) (xy 107.934997 129.177273) + (xy 107.964001 129.201076) (xy 110.137619 131.374695) (xy 109.971493 131.419208) (xy 109.854426 131.463269) (xy 109.748204 131.529321) + (xy 109.65691 131.614828) (xy 109.584051 131.716502) (xy 109.532428 131.830436) (xy 109.504025 131.952253) (xy 109.499932 132.07727) + (xy 109.520308 132.200683) (xy 110.037946 134.132535) (xy 110.082007 134.249602) (xy 110.148059 134.355824) (xy 110.233566 134.447118) + (xy 110.33524 134.519977) (xy 110.449174 134.5716) (xy 110.570991 134.600003) (xy 110.696008 134.604096) (xy 110.819421 134.58372) + (xy 111.996083 134.268434) (xy 114.027956 136.300308) (xy 114.051754 136.329306) (xy 114.080752 136.353104) (xy 114.167478 136.424279) + (xy 114.234305 136.459999) (xy 114.299508 136.494851) (xy 114.442769 136.538308) (xy 114.554422 136.549305) (xy 114.554432 136.549305) + (xy 114.591755 136.552981) (xy 114.629078 136.549305) (xy 121.923373 136.549305) (xy 121.960695 136.552981) (xy 121.998017 136.549305) + (xy 121.998028 136.549305) (xy 122.109681 136.538308) (xy 122.252942 136.494851) (xy 122.384971 136.424279) (xy 122.500696 136.329306) + (xy 122.524498 136.300303) (xy 123.041923 135.782878) (xy 123.145521 135.739967) (xy 123.282281 135.648587) (xy 123.398587 135.532281) + (xy 123.489967 135.395521) (xy 123.552911 135.24356) (xy 123.585 135.08224) (xy 123.585 134.91776) (xy 123.552911 134.75644) + (xy 123.489967 134.604479) (xy 123.398587 134.467719) (xy 123.282281 134.351413) (xy 123.145521 134.260033) (xy 122.99356 134.197089) + (xy 122.865488 134.171613) (xy 122.928117 134.108985) (xy 122.967719 134.148587) (xy 123.104479 134.239967) (xy 123.25644 134.302911) + (xy 123.41776 134.335) (xy 123.58224 134.335) (xy 123.74356 134.302911) (xy 123.895521 134.239967) (xy 124.032281 134.148587) + (xy 124.148587 134.032281) (xy 124.239967 133.895521) (xy 124.302911 133.74356) (xy 124.332984 133.592374) (xy 125.96571 133.154886) + (xy 126.082777 133.110825) (xy 126.188999 133.044773) (xy 126.280293 132.959266) (xy 126.353152 132.857592) (xy 126.404775 132.743658) + (xy 126.433178 132.621841) (xy 126.437271 132.496824) (xy 126.416895 132.373411) (xy 126.118018 131.257987) (xy 126.711003 130.665002) + (xy 126.740001 130.641204) (xy 126.834974 130.525479) (xy 126.905546 130.39345) (xy 126.949003 130.250189) (xy 126.96 130.138536) + (xy 126.96 130.138527) (xy 126.963676 130.101204) (xy 126.96 130.063881) (xy 126.96 125.313072) (xy 128.2 125.313072) + (xy 128.324482 125.300812) (xy 128.44418 125.264502) (xy 128.554494 125.205537) (xy 128.651185 125.126185) (xy 128.730537 125.029494) + (xy 128.746866 124.998945) (xy 128.75644 125.002911) (xy 128.91776 125.035) (xy 129.08224 125.035) (xy 129.24356 125.002911) + (xy 129.347157 124.96) (xy 129.560199 124.96) (xy 129.573701 124.973502) (xy 130.711928 126.11173) (xy 130.711928 127.28) + (xy 130.724188 127.404482) (xy 130.760498 127.52418) (xy 130.819463 127.634494) (xy 130.898815 127.731185) (xy 130.995506 127.810537) + (xy 131.10582 127.869502) (xy 131.225518 127.905812) (xy 131.35 127.918072) (xy 131.845674 127.918072) (xy 131.865026 127.954276) + (xy 131.902142 127.999502) (xy 131.959999 128.070001) (xy 131.989003 128.093804) (xy 134.961398 131.0662) (xy 134.437803 131.0662) + (xy 133.407279 130.035677) (xy 133.364367 129.932079) (xy 133.272987 129.795319) (xy 133.156681 129.679013) (xy 133.019921 129.587633) + (xy 132.86796 129.524689) (xy 132.70664 129.4926) (xy 132.54216 129.4926) (xy 132.38084 129.524689) (xy 132.228879 129.587633) + (xy 132.092119 129.679013) (xy 131.975813 129.795319) (xy 131.884433 129.932079) (xy 131.821489 130.08404) (xy 131.7894 130.24536) + (xy 131.7894 130.40984) (xy 131.821489 130.57116) (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) + (xy 132.228879 131.067567) (xy 132.332477 131.110479) (xy 133.559205 132.337208) (xy 133.582999 132.366201) (xy 133.611992 132.389995) + (xy 133.611996 132.389999) (xy 133.674055 132.440929) (xy 133.698724 132.461174) (xy 133.830753 132.531746) (xy 133.974014 132.575203) + (xy 134.085667 132.5862) (xy 134.085676 132.5862) (xy 134.122999 132.589876) (xy 134.160322 132.5862) (xy 142.970643 132.5862) + (xy 143.07424 132.629111) (xy 143.23556 132.6612) (xy 143.40004 132.6612) (xy 143.56136 132.629111) (xy 143.713321 132.566167) + (xy 143.850081 132.474787) (xy 143.966387 132.358481) (xy 144.057767 132.221721) (xy 144.120711 132.06976) (xy 144.1528 131.90844) + (xy 144.1528 131.74396) (xy 144.120711 131.58264) (xy 144.073474 131.4686) (xy 144.524078 131.4686) (xy 144.5614 131.472276) + (xy 144.598722 131.4686) (xy 144.598733 131.4686) (xy 144.710386 131.457603) (xy 144.853647 131.414146) (xy 144.985676 131.343574) + (xy 145.101401 131.248601) (xy 145.125203 131.219598) (xy 145.711002 130.6338) (xy 145.740001 130.610001) (xy 145.834974 130.494276) + (xy 145.854326 130.458072) (xy 146.35 130.458072) (xy 146.474482 130.445812) (xy 146.59418 130.409502) (xy 146.704494 130.350537) + (xy 146.801185 130.271185) (xy 146.880537 130.174494) (xy 146.912872 130.114) (xy 147.441043 130.114) (xy 147.54464 130.156911) + (xy 147.70596 130.189) (xy 147.87044 130.189) (xy 148.03176 130.156911) (xy 148.183721 130.093967) (xy 148.320481 130.002587) + (xy 148.436787 129.886281) (xy 148.528167 129.749521) (xy 148.591111 129.59756) (xy 148.6232 129.43624) (xy 148.6232 129.27176) + (xy 148.591111 129.11044) (xy 148.528167 128.958479) (xy 148.436787 128.821719) (xy 148.320481 128.705413) (xy 148.183721 128.614033) + (xy 148.03176 128.551089) (xy 147.87044 128.519) (xy 147.70596 128.519) (xy 147.54464 128.551089) (xy 147.441043 128.594) + (xy 146.988072 128.594) (xy 146.988072 127.82) (xy 146.975812 127.695518) (xy 146.939502 127.57582) (xy 146.880537 127.465506) + (xy 146.801185 127.368815) (xy 146.704494 127.289463) (xy 146.59418 127.230498) (xy 146.474482 127.194188) (xy 146.35 127.181928) + (xy 145.230748 127.181928) (xy 145.362953 126.862756) (xy 145.445 126.450279) (xy 145.445 126.029721) (xy 145.362953 125.617244) + (xy 145.202012 125.228698) (xy 145.164985 125.173283) (xy 145.330779 125.104609) (xy 145.590379 124.93115) (xy 145.81115 124.710379) + (xy 145.984609 124.450779) (xy 146.104089 124.162327) (xy 146.165 123.856109) (xy 146.165 123.543891) (xy 146.104089 123.237673) + (xy 145.984609 122.949221) (xy 145.81115 122.689621) (xy 145.590379 122.46885) (xy 145.330779 122.295391) (xy 145.042327 122.175911) + (xy 144.736109 122.115) (xy 144.423891 122.115) (xy 144.117673 122.175911) (xy 144.023303 122.215) (xy 143.85374 122.215) + (xy 143.566842 122.272068) (xy 143.296589 122.38401) (xy 143.053368 122.546525) (xy 142.846525 122.753368) (xy 142.68401 122.996589) + (xy 142.572068 123.266842) (xy 142.515 123.55374) (xy 142.515 123.84626) (xy 142.572068 124.133158) (xy 142.607988 124.219876) + (xy 142.298698 124.347988) (xy 142.076252 124.496622) (xy 142.081817 124.483186) (xy 142.185 123.964449) (xy 142.185 123.435551) + (xy 142.081817 122.916814) (xy 141.879417 122.428175) (xy 141.585576 121.988412) (xy 141.261364 121.6642) (xy 145.299401 121.6642) + (xy 153.500204 129.865004) (xy 153.524002 129.894002) (xy 153.639727 129.988975) (xy 153.771756 130.059547) (xy 153.915017 130.103004) + (xy 154.02667 130.114001) (xy 154.026679 130.114001) (xy 154.064002 130.117677) (xy 154.101325 130.114001) (xy 169.757177 130.114001) + (xy 169.794499 130.117677) (xy 169.831821 130.114001) (xy 169.831832 130.114001) (xy 169.943485 130.103004) (xy 170.086746 130.059547) + (xy 170.218775 129.988975) (xy 170.3345 129.894002) (xy 170.358302 129.864999) (xy 170.6245 129.598801) (xy 173.159701 132.134003) + (xy 173.183499 132.163001) (xy 173.212497 132.186799) (xy 173.299223 132.257974) (xy 173.431253 132.328546) (xy 173.574514 132.372003) + (xy 173.686167 132.383) (xy 173.686176 132.383) (xy 173.723499 132.386676) (xy 173.760822 132.383) (xy 177.717843 132.383) + (xy 177.82144 132.425911) (xy 177.98276 132.458) (xy 178.14724 132.458) (xy 178.30856 132.425911) (xy 178.460521 132.362967) + (xy 178.597281 132.271587) (xy 178.713587 132.155281) (xy 178.804967 132.018521) (xy 178.867911 131.86656) (xy 178.891494 131.748) + (xy 181.194678 131.748) (xy 181.232 131.751676) (xy 181.269322 131.748) (xy 181.269333 131.748) (xy 181.380986 131.737003) + (xy 181.524247 131.693546) (xy 181.656276 131.622974) (xy 181.772001 131.528001) (xy 181.795804 131.498997) (xy 182.736729 130.558072) + (xy 184.45 130.558072) (xy 184.574482 130.545812) (xy 184.69418 130.509502) (xy 184.804494 130.450537) (xy 184.901185 130.371185) + (xy 184.980537 130.274494) (xy 185.039502 130.16418) (xy 185.075812 130.044482) (xy 185.088072 129.92) (xy 185.088072 128.343229) + (xy 194.671302 118.76) (xy 202.891678 118.76) (xy 202.929 118.763676) (xy 202.966322 118.76) (xy 202.966333 118.76) + (xy 203.077986 118.749003) (xy 203.221247 118.705546) (xy 203.353276 118.634974) (xy 203.469001 118.540001) (xy 203.492803 118.510998) + (xy 204.743813 117.25999) (xy 209.652843 117.25999) (xy 209.75644 117.302901) (xy 209.91776 117.33499) (xy 210.08224 117.33499) + (xy 210.24356 117.302901) (xy 210.395521 117.239957) (xy 210.402955 117.23499) (xy 221.07053 117.23499) (xy 221.107852 117.238666) + (xy 221.145174 117.23499) (xy 221.145185 117.23499) (xy 221.256838 117.223993) (xy 221.400099 117.180536) (xy 221.532128 117.109964) + (xy 221.647853 117.014991) (xy 221.671656 116.985987) (xy 221.960997 116.696646) (xy 221.990001 116.672843) (xy 222.084974 116.557118) + (xy 222.155546 116.425089) (xy 222.199003 116.281828) (xy 222.201343 116.258072) (xy 222.6 116.258072) (xy 222.724482 116.245812) + (xy 222.84418 116.209502) (xy 222.954494 116.150537) (xy 223.051185 116.071185) (xy 223.130537 115.974494) (xy 223.189502 115.86418) + (xy 223.225812 115.744482) (xy 223.238072 115.62) (xy 223.238072 114.05673) (xy 223.361004 113.933798) (xy 223.390001 113.910001) + (xy 223.416332 113.877917) (xy 223.484974 113.794277) (xy 223.555546 113.662247) (xy 223.566009 113.627754) (xy 223.599003 113.518986) + (xy 223.61 113.407333) (xy 223.61 113.407323) (xy 223.613676 113.37) (xy 223.61 113.332677) (xy 223.61 107.387325) + (xy 223.613676 107.35) (xy 223.61 107.312675) (xy 223.61 107.312667) (xy 223.599003 107.201014) (xy 223.555546 107.057753) + (xy 223.484974 106.925724) (xy 223.390001 106.809999) (xy 223.361003 106.786201) (xy 222.035009 105.460208) (xy 222.035009 101.275922) + (xy 222.038685 101.238599) (xy 222.035009 101.201276) (xy 222.035009 101.201266) (xy 222.024012 101.089613) (xy 221.980555 100.946352) + (xy 221.909983 100.814323) (xy 221.81501 100.698598) (xy 221.786011 100.674799) (xy 221.51 100.398789) (xy 221.51 98.097157) + (xy 221.552911 97.99356) (xy 221.585 97.83224) (xy 221.585 97.66776) (xy 221.552911 97.50644) (xy 221.51 97.402843) + (xy 221.51 97.258072) (xy 222.55 97.258072) (xy 222.674482 97.245812) (xy 222.79418 97.209502) (xy 222.904494 97.150537) + (xy 223.001185 97.071185) (xy 223.080537 96.974494) (xy 223.139502 96.86418) (xy 223.175812 96.744482) (xy 223.188072 96.62) + (xy 223.188072 94.62) (xy 223.175812 94.495518) (xy 223.139502 94.37582) (xy 223.080537 94.265506) (xy 223.001185 94.168815) + (xy 222.904494 94.089463) (xy 222.815001 94.041627) (xy 222.815001 80.017314) (xy 222.818677 79.979991) (xy 222.815001 79.942668) + (xy 222.815001 79.942658) (xy 222.804004 79.831005) (xy 222.760547 79.687744) (xy 222.689975 79.555715) (xy 222.595002 79.43999) + (xy 222.566004 79.416192) (xy 221.332879 78.183068) (xy 221.31 78.127833) (xy 221.31 78.058072) (xy 222.55 78.058072) + (xy 222.674482 78.045812) (xy 222.79418 78.009502) (xy 222.904494 77.950537) (xy 223.001185 77.871185) (xy 223.080537 77.774494) + (xy 223.139502 77.66418) (xy 223.175812 77.544482) (xy 223.188072 77.42) (xy 223.188072 75.42) (xy 223.175812 75.295518) + (xy 223.139502 75.17582) (xy 223.080537 75.065506) (xy 223.001185 74.968815) (xy 222.904494 74.889463) (xy 222.79418 74.830498) + (xy 222.674482 74.794188) (xy 222.55 74.781928) (xy 222.16 74.781928) (xy 222.16 72.881803) (xy 222.566005 72.475799) + (xy 222.595002 72.452002) (xy 222.689975 72.336277) (xy 222.760547 72.204248) (xy 222.804004 72.060987) (xy 222.815001 71.949334) + (xy 222.815001 71.949325) (xy 222.818677 71.912002) (xy 222.815001 71.874679) (xy 222.815001 61.342334) (xy 222.818678 61.305001) + (xy 222.804004 61.156015) (xy 222.760547 61.012754) (xy 222.689975 60.880725) (xy 222.648794 60.830546) (xy 222.595002 60.765) + (xy 222.566004 60.741202) (xy 221.282879 59.458078) (xy 221.26 59.402843) (xy 221.26 59.158072) (xy 222.65 59.158072) + (xy 222.774482 59.145812) (xy 222.89418 59.109502) (xy 223.004494 59.050537) (xy 223.101185 58.971185) (xy 223.180537 58.874494) + (xy 223.239502 58.76418) (xy 223.275812 58.644482) (xy 223.288072 58.52) (xy 223.288072 56.52) (xy 223.275812 56.395518) + (xy 223.239502 56.27582) (xy 223.180537 56.165506) (xy 223.101185 56.068815) (xy 223.004494 55.989463) (xy 222.89418 55.930498) + (xy 222.774482 55.894188) (xy 222.65 55.881928) (xy 221.530748 55.881928) (xy 221.662953 55.562756) (xy 221.745 55.150279) + (xy 221.745 54.729721) (xy 221.662953 54.317244) (xy 221.502012 53.928698) (xy 221.464985 53.873283) (xy 221.630779 53.804609) + (xy 221.890379 53.63115) (xy 222.11115 53.410379) (xy 222.284609 53.150779) (xy 222.404089 52.862327) (xy 222.465 52.556109) + (xy 222.465 52.243891) (xy 222.404089 51.937673) (xy 222.284609 51.649221) (xy 222.11115 51.389621) (xy 221.890379 51.16885) + (xy 221.630779 50.995391) (xy 221.342327 50.875911) (xy 221.036109 50.815) (xy 220.723891 50.815) (xy 220.417673 50.875911) + (xy 220.323303 50.915) (xy 220.15374 50.915) (xy 219.866842 50.972068) (xy 219.596589 51.08401) (xy 219.353368 51.246525) + (xy 219.146525 51.453368) (xy 218.98401 51.696589) (xy 218.872068 51.966842) (xy 218.815 52.25374) (xy 218.815 52.54626) + (xy 218.872068 52.833158) (xy 218.907988 52.919876) (xy 218.598698 53.047988) (xy 218.376252 53.196622) (xy 218.381817 53.183186) + (xy 218.485 52.664449) (xy 218.485 52.135551) (xy 218.381817 51.616814) (xy 218.179417 51.128175) (xy 217.885576 50.688412) + (xy 217.511588 50.314424) (xy 217.071825 50.020583) (xy 216.687522 49.8614) (xy 217.415123 49.8614) (xy 217.45 49.864835) + (xy 217.484877 49.8614) (xy 217.589184 49.851127) (xy 217.72302 49.810528) (xy 217.846363 49.7446) (xy 217.954475 49.655875) + (xy 218.0432 49.547763) (xy 218.109128 49.42442) (xy 218.149727 49.290584) (xy 218.163435 49.1514) (xy 218.16 49.116523) + (xy 218.16 47.628) (xy 218.327 47.628) (xy 218.327 47.648) (xy 218.347 47.648) (xy 218.347 47.902) + (xy 218.327 47.902) (xy 218.327 48.75125) (xy 218.48575 48.91) (xy 219 48.913072) (xy 219.124482 48.900812) + (xy 219.24418 48.864502) (xy 219.354494 48.805537) (xy 219.451185 48.726185) (xy 219.530537 48.629494) (xy 219.589502 48.51918) + (xy 219.625812 48.399482) (xy 219.638072 48.275) (xy 219.635 48.06075) (xy 219.476252 47.902002) (xy 219.635 47.902002) + (xy 219.635 47.804614) (xy 219.64356 47.802911) (xy 219.795521 47.739967) (xy 219.932281 47.648587) (xy 220.048587 47.532281) + (xy 220.139967 47.395521) (xy 220.202911 47.24356) (xy 220.235 47.08224) (xy 220.235 46.91776) (xy 220.202911 46.75644) + (xy 220.139967 46.604479) (xy 220.048587 46.467719) (xy 219.932281 46.351413) (xy 219.795521 46.260033) (xy 219.691923 46.217122) + (xy 219.638072 46.16327) (xy 219.638072 45.525) (xy 219.625812 45.400518) (xy 219.589502 45.28082) (xy 219.530537 45.170506) + (xy 219.451185 45.073815) (xy 219.354494 44.994463) (xy 219.24418 44.935498) (xy 219.16 44.909962) (xy 219.16 44.747157) + (xy 219.202911 44.64356) (xy 219.235 44.48224) (xy 219.235 44.31776) (xy 219.202911 44.15644) (xy 219.139967 44.004479) + (xy 219.048587 43.867719) (xy 218.932281 43.751413) (xy 218.795521 43.660033) (xy 218.64356 43.597089) (xy 218.48224 43.565) + (xy 218.31776 43.565) (xy 218.15644 43.597089) (xy 218.004479 43.660033) (xy 217.867719 43.751413) (xy 217.751413 43.867719) + (xy 217.67743 43.978442) (xy 217.589184 43.951673) (xy 217.484877 43.9414) (xy 217.45 43.937965) (xy 217.415123 43.9414) + (xy 213.984877 43.9414) (xy 213.95 43.937965) (xy 213.915123 43.9414) (xy 213.810816 43.951673) (xy 213.67698 43.992272) + (xy 213.553637 44.0582) (xy 213.445525 44.146925) (xy 213.3568 44.255037) (xy 213.290872 44.37838) (xy 213.250273 44.512216) + (xy 213.236565 44.6514) (xy 213.240001 44.686287) (xy 213.240001 44.886928) (xy 212.6 44.886928) (xy 212.475518 44.899188) + (xy 212.35582 44.935498) (xy 212.245506 44.994463) (xy 212.148815 45.073815) (xy 212.094499 45.14) (xy 211.818466 45.14) + (xy 211.788641 45.137063) (xy 210.430332 43.778754) (xy 210.402617 43.744983) (xy 210.267859 43.634389) (xy 210.114113 43.552211) + (xy 209.94729 43.501605) (xy 209.817277 43.4888) (xy 209.817269 43.4888) (xy 209.7738 43.484519) (xy 209.730331 43.4888) + (xy 206.365023 43.4888) (xy 206.239249 43.385579) (xy 206.085503 43.303401) (xy 205.91868 43.252795) (xy 205.788667 43.23999) + (xy 205.788659 43.23999) (xy 205.74519 43.235709) (xy 205.701721 43.23999) (xy 194.668479 43.23999) (xy 194.62501 43.235709) + (xy 194.581541 43.23999) (xy 194.581533 43.23999) (xy 194.45152 43.252795) (xy 194.284697 43.303401) (xy 194.130951 43.385579) + (xy 193.996193 43.496173) (xy 193.968476 43.529946) (xy 193.704956 43.793466) (xy 193.671183 43.821183) (xy 193.645482 43.8525) + (xy 193.379079 43.8525) (xy 188.334046 38.807468) (xy 188.181533 38.654955) (xy 188.153816 38.621182) (xy 188.019058 38.510588) + (xy 187.865312 38.42841) (xy 187.698489 38.377804) (xy 187.568476 38.364999) (xy 187.568468 38.364999) (xy 187.524999 38.360718) + (xy 187.48153 38.364999) (xy 175.75099 38.364999) (xy 175.707524 38.360718) (xy 175.664058 38.364999) (xy 175.664048 38.364999) + (xy 175.534035 38.377804) (xy 175.367212 38.42841) (xy 175.213466 38.510588) (xy 175.078708 38.621182) (xy 175.050991 38.654955) + (xy 174.952736 38.75321) (xy 169.314789 38.75321) (xy 168.345046 37.783468) (xy 168.244059 37.70059) (xy 168.090313 37.618412) + (xy 168.075496 37.613917) (xy 166.482013 36.020435) (xy 166.454296 35.986662) (xy 166.319538 35.876068) (xy 166.165792 35.79389) + (xy 165.998969 35.743284) (xy 165.868956 35.730479) (xy 165.868948 35.730479) (xy 165.825479 35.726198) (xy 165.78201 35.730479) + (xy 156.517987 35.730479) (xy 156.47452 35.726198) (xy 156.431054 35.730479) (xy 156.431044 35.730479) (xy 156.301031 35.743284) + (xy 156.134208 35.79389) (xy 155.980462 35.876068) (xy 155.845704 35.986662) (xy 155.817987 36.020435) (xy 155.404952 36.43347) + (xy 155.371184 36.461183) (xy 155.260589 36.595941) (xy 155.178411 36.749687) (xy 155.127805 36.91651) (xy 155.115 37.046523) + (xy 155.115 37.046531) (xy 155.110719 37.09) (xy 155.115 37.133469) (xy 155.115 37.557317) (xy 155.045506 37.594463) + (xy 154.948815 37.673815) (xy 154.869463 37.770506) (xy 154.818954 37.865) (xy 153.825476 37.865) (xy 153.782 37.860718) + (xy 153.738523 37.865) (xy 137.368479 37.865) (xy 137.32501 37.860719) (xy 137.281541 37.865) (xy 137.281533 37.865) + (xy 137.15152 37.877805) (xy 136.984697 37.928411) (xy 136.857903 37.996183) (xy 136.830951 38.010589) (xy 136.729963 38.093468) + (xy 136.729961 38.09347) (xy 136.696193 38.121183) (xy 136.66848 38.154951) (xy 134.904958 39.918474) (xy 134.904953 39.918478) + (xy 134.904951 39.91848) (xy 134.871183 39.946193) (xy 134.84347 39.979961) (xy 134.308432 40.515) (xy 127.643465 40.515) + (xy 127.599999 40.510719) (xy 127.556533 40.515) (xy 118.643465 40.515) (xy 118.599999 40.510719) (xy 118.556533 40.515) + (xy 118.556523 40.515) (xy 118.42651 40.527805) (xy 118.259687 40.578411) (xy 118.105941 40.660589) (xy 118.097828 40.667247) + (xy 118.004953 40.743468) (xy 118.004951 40.74347) (xy 117.971183 40.771183) (xy 117.94347 40.804951) (xy 116.833423 41.914999) + (xy 116.131464 41.914999) (xy 116.087998 41.910718) (xy 116.044532 41.914999) (xy 116.044522 41.914999) (xy 115.914509 41.927804) + (xy 115.747686 41.97841) (xy 115.59394 42.060588) (xy 115.459182 42.171182) (xy 115.431465 42.204955) (xy 115.154955 42.481465) + (xy 115.121182 42.509182) (xy 115.010588 42.643941) (xy 114.92841 42.797687) (xy 114.896094 42.904217) (xy 114.877804 42.964509) + (xy 114.876211 42.980685) (xy 114.864999 43.094523) (xy 114.864999 43.09453) (xy 114.860718 43.137999) (xy 114.864999 43.181469) + (xy 114.864999 43.615) (xy 113.793465 43.615) (xy 113.749999 43.610719) (xy 113.706533 43.615) (xy 113.706523 43.615) + (xy 113.57651 43.627805) (xy 113.409687 43.678411) (xy 113.255941 43.760589) (xy 113.244474 43.77) (xy 113.154953 43.843468) + (xy 113.154951 43.84347) (xy 113.121183 43.871183) (xy 113.09347 43.904951) (xy 111.129958 45.868464) (xy 111.129953 45.868468) + (xy 110.015389 46.983032) (xy 109.986451 46.902722) (xy 109.924471 46.786765) (xy 109.68438 46.719785) (xy 108.89842 47.505745) + (xy 108.912563 47.519888) (xy 108.732958 47.699493) (xy 108.718815 47.68535) (xy 108.704673 47.699493) (xy 108.525068 47.519888) + (xy 108.53921 47.505745) (xy 108.525068 47.491603) (xy 108.704673 47.311998) (xy 108.718815 47.32614) (xy 109.504775 46.54018) + (xy 109.437795 46.300089) (xy 109.302055 46.23626) (xy 109.380542 46.20375) (xy 109.60935 46.050865) (xy 109.803935 45.85628) + (xy 109.95682 45.627472) (xy 110.062129 45.373235) (xy 110.115815 45.103337) (xy 110.115815 44.828153) (xy 110.062129 44.558255) + (xy 109.95682 44.304018) (xy 109.803935 44.07521) (xy 109.60935 43.880625) (xy 109.380542 43.72774) (xy 109.3033 43.695745) + (xy 109.380542 43.66375) (xy 109.60935 43.510865) (xy 109.803935 43.31628) (xy 109.95682 43.087472) (xy 110.062129 42.833235) + (xy 110.115815 42.563337) (xy 110.115815 42.288153) (xy 110.062129 42.018255) (xy 109.95682 41.764018) (xy 109.803935 41.53521) + (xy 109.60935 41.340625) (xy 109.380542 41.18774) (xy 109.126305 41.082431) (xy 108.856407 41.028745) (xy 108.804337 41.028745) + (xy 108.763314 40.82251) (xy 108.658005 40.568273) (xy 108.50512 40.339465) (xy 108.310535 40.14488) (xy 108.081727 39.991995) + (xy 107.82749 39.886686) (xy 107.557592 39.833) (xy 107.282408 39.833) (xy 107.01251 39.886686) (xy 106.758273 39.991995) + (xy 106.529465 40.14488) (xy 106.33488 40.339465) (xy 106.181995 40.568273) (xy 106.076686 40.82251) (xy 106.071225 40.849967) + (xy 105.991928 40.817121) (xy 105.89381 40.719003) (xy 105.870007 40.689999) (xy 105.754282 40.595026) (xy 105.622253 40.524454) + (xy 105.478992 40.480997) (xy 105.367339 40.47) (xy 105.367328 40.47) (xy 105.330006 40.466324) (xy 105.292684 40.47) + (xy 93.352341 40.47) (xy 93.26512 40.339465) (xy 93.070535 40.14488) (xy 92.841727 39.991995) (xy 92.58749 39.886686) + (xy 92.317592 39.833) (xy 92.042408 39.833) (xy 91.77251 39.886686) (xy 91.518273 39.991995) (xy 91.289465 40.14488) + (xy 91.09488 40.339465) (xy 90.941995 40.568273) (xy 90.836686 40.82251) (xy 90.783 41.092408) (xy 90.783 41.367592) + (xy 90.836686 41.63749) (xy 90.941995 41.891727) (xy 91.09488 42.120535) (xy 91.289465 42.31512) (xy 91.518273 42.468005) + (xy 91.595515 42.5) (xy 91.518273 42.531995) (xy 91.289465 42.68488) (xy 91.09488 42.879465) (xy 90.941995 43.108273) + (xy 90.836686 43.36251) (xy 90.783 43.632408) (xy 90.783 43.907592) (xy 90.836686 44.17749) (xy 90.941995 44.431727) + (xy 91.09488 44.660535) (xy 91.289465 44.85512) (xy 91.518273 45.008005) (xy 91.589943 45.037692) (xy 91.576977 45.042364) + (xy 91.46102 45.104344) (xy 91.39404 45.344435) (xy 92.18 46.130395) (xy 92.96596 45.344435) (xy 92.956048 45.308907) + (xy 93.29921 44.965745) (xy 93.285068 44.951603) (xy 93.464673 44.771998) (xy 93.478815 44.78614) (xy 93.492958 44.771998) + (xy 93.672563 44.951603) (xy 93.65842 44.965745) (xy 94.44438 45.751705) (xy 94.684471 45.684725) (xy 94.801571 45.435697) + (xy 94.867838 45.16861) (xy 94.875429 45.006688) (xy 95.01776 45.035) (xy 95.18224 45.035) (xy 95.34356 45.002911) + (xy 95.495521 44.939967) (xy 95.632281 44.848587) (xy 95.748587 44.732281) (xy 95.839967 44.595521) (xy 95.867107 44.53) + (xy 105.049889 44.53) (xy 105.051413 44.532281) (xy 105.167719 44.648587) (xy 105.304479 44.739967) (xy 105.45644 44.802911) + (xy 105.61776 44.835) (xy 105.78224 44.835) (xy 105.94356 44.802911) (xy 106.095521 44.739967) (xy 106.232281 44.648587) + (xy 106.348587 44.532281) (xy 106.351882 44.52735) (xy 106.454435 44.55596) (xy 107.240395 43.77) (xy 107.226253 43.755858) + (xy 107.405858 43.576253) (xy 107.42 43.590395) (xy 107.434143 43.576253) (xy 107.613748 43.755858) (xy 107.599605 43.77) + (xy 107.613748 43.784143) (xy 107.434143 43.963748) (xy 107.42 43.949605) (xy 106.63404 44.735565) (xy 106.70102 44.975656) + (xy 106.83676 45.039485) (xy 106.758273 45.071995) (xy 106.529465 45.22488) (xy 106.33488 45.419465) (xy 106.321159 45.44) + (xy 105.737322 45.44) (xy 105.699999 45.436324) (xy 105.662676 45.44) (xy 105.662667 45.44) (xy 105.551014 45.450997) + (xy 105.407753 45.494454) (xy 105.275724 45.565026) (xy 105.159999 45.659999) (xy 105.136201 45.688997) (xy 104.079454 46.745745) + (xy 94.651156 46.745745) (xy 94.563935 46.61521) (xy 94.36935 46.420625) (xy 94.140542 46.26774) (xy 94.068872 46.238053) + (xy 94.081838 46.233381) (xy 94.197795 46.171401) (xy 94.264775 45.93131) (xy 93.478815 45.14535) (xy 92.692855 45.93131) + (xy 92.702767 45.966838) (xy 92.359605 46.31) (xy 92.373748 46.324143) (xy 92.194143 46.503748) (xy 92.18 46.489605) + (xy 91.39404 47.275565) (xy 91.46102 47.515656) (xy 91.591644 47.577079) (xy 91.576977 47.582364) (xy 91.46102 47.644344) + (xy 91.39404 47.884435) (xy 92.18 48.670395) (xy 92.194143 48.656253) (xy 92.373748 48.835858) (xy 92.359605 48.85) + (xy 92.373748 48.864143) (xy 92.194143 49.043748) (xy 92.18 49.029605) (xy 91.39404 49.815565) (xy 91.46102 50.055656) + (xy 91.59676 50.119485) (xy 91.518273 50.151995) (xy 91.289465 50.30488) (xy 91.09488 50.499465) (xy 90.941995 50.728273) + (xy 90.836686 50.98251) (xy 90.783 51.252408) (xy 90.783 51.527592) (xy 90.836686 51.79749) (xy 90.941995 52.051727) + (xy 91.09488 52.280535) (xy 91.289465 52.47512) (xy 91.518273 52.628005) (xy 91.595515 52.66) (xy 91.518273 52.691995) + (xy 91.289465 52.84488) (xy 91.09488 53.039465) (xy 90.941995 53.268273) (xy 90.836686 53.52251) (xy 90.783 53.792408) + (xy 90.783 54.067592) (xy 90.836686 54.33749) (xy 90.941995 54.591727) (xy 91.09488 54.820535) (xy 91.289465 55.01512) + (xy 91.518273 55.168005) (xy 91.595515 55.2) (xy 91.518273 55.231995) (xy 91.289465 55.38488) (xy 91.09488 55.579465) + (xy 90.941995 55.808273) (xy 90.836686 56.06251) (xy 90.783 56.332408) (xy 90.783 56.607592) (xy 90.836686 56.87749) + (xy 90.941995 57.131727) (xy 91.09488 57.360535) (xy 91.289465 57.55512) (xy 91.518273 57.708005) (xy 91.595515 57.74) + (xy 91.518273 57.771995) (xy 91.289465 57.92488) (xy 91.09488 58.119465) (xy 90.941995 58.348273) (xy 90.836686 58.60251) + (xy 90.783 58.872408) (xy 90.783 59.147592) (xy 90.836686 59.41749) (xy 90.941995 59.671727) (xy 91.09488 59.900535) + (xy 91.289465 60.09512) (xy 91.518273 60.248005) (xy 91.595515 60.28) (xy 91.518273 60.311995) (xy 91.289465 60.46488) + (xy 91.09488 60.659465) (xy 90.941995 60.888273) (xy 90.836686 61.14251) (xy 90.783 61.412408) (xy 90.783 61.687592) + (xy 90.836686 61.95749) (xy 90.941995 62.211727) (xy 91.09488 62.440535) (xy 91.289465 62.63512) (xy 91.518273 62.788005) + (xy 91.595515 62.82) (xy 91.518273 62.851995) (xy 91.289465 63.00488) (xy 91.09488 63.199465) (xy 90.941995 63.428273) + (xy 90.836686 63.68251) (xy 90.783 63.952408) (xy 90.783 64.227592) (xy 90.836686 64.49749) (xy 90.941995 64.751727) + (xy 91.09488 64.980535) (xy 91.289465 65.17512) (xy 91.518273 65.328005) (xy 91.595515 65.36) (xy 91.518273 65.391995) + (xy 91.289465 65.54488) (xy 91.09488 65.739465) (xy 90.941995 65.968273) (xy 90.836686 66.22251) (xy 90.783 66.492408) + (xy 90.783 66.767592) (xy 90.836686 67.03749) (xy 90.941995 67.291727) (xy 91.09488 67.520535) (xy 91.289465 67.71512) + (xy 91.518273 67.868005) (xy 91.595515 67.9) (xy 91.518273 67.931995) (xy 91.289465 68.08488) (xy 91.09488 68.279465) + (xy 90.941995 68.508273) (xy 90.836686 68.76251) (xy 90.783 69.032408) (xy 90.783 69.307592) (xy 90.836686 69.57749) + (xy 90.941995 69.831727) (xy 91.09488 70.060535) (xy 91.289465 70.25512) (xy 91.518273 70.408005) (xy 91.77251 70.513314) + (xy 92.042408 70.567) (xy 92.094478 70.567) (xy 92.135501 70.773235) (xy 92.24081 71.027472) (xy 92.393695 71.25628) + (xy 92.58828 71.450865) (xy 92.817088 71.60375) (xy 93.071325 71.709059) (xy 93.341223 71.762745) (xy 93.616407 71.762745) + (xy 93.886305 71.709059) (xy 94.04 71.645396) (xy 94.040001 73.544048) (xy 93.4285 73.544048) (xy 93.304018 73.556308) + (xy 93.18432 73.592618) (xy 93.074006 73.651583) (xy 92.977315 73.730935) (xy 92.897963 73.827626) (xy 92.838998 73.93794) + (xy 92.802688 74.057638) (xy 92.790428 74.18212) (xy 92.790428 74.81712) (xy 92.802688 74.941602) (xy 92.820403 75) + (xy 92.802688 75.058398) (xy 92.790428 75.18288) (xy 92.790428 75.81788) (xy 92.802688 75.942362) (xy 92.838998 76.06206) + (xy 92.897963 76.172374) (xy 92.977315 76.269065) (xy 93.074006 76.348417) (xy 93.18432 76.407382) (xy 93.24 76.424272) + (xy 93.240001 80.935197) (xy 92.36401 81.811189) (xy 92.335009 81.834989) (xy 92.311211 81.863987) (xy 92.065995 82.109203) + (xy 91.991111 82.086487) (xy 91.77295 82.065) (xy 90.974885 82.065) (xy 91.042252 82.019987) (xy 91.269987 81.792252) + (xy 91.448918 81.524463) (xy 91.572168 81.226912) (xy 91.635 80.911033) (xy 91.635 80.588967) (xy 91.572168 80.273088) + (xy 91.448918 79.975537) (xy 91.269987 79.707748) (xy 91.042252 79.480013) (xy 90.774463 79.301082) (xy 90.476912 79.177832) + (xy 90.161033 79.115) (xy 89.838967 79.115) (xy 89.523088 79.177832) (xy 89.225537 79.301082) (xy 88.959613 79.478767) + (xy 88.959539 75.470069) (xy 89.044193 75.385415) (xy 89.139956 75.649814) (xy 89.429571 75.790704) (xy 89.741108 75.872384) + (xy 90.062595 75.891718) (xy 90.381675 75.847961) (xy 90.686088 75.742795) (xy 90.860044 75.649814) (xy 90.955808 75.385413) + (xy 90 74.429605) (xy 89.985858 74.443748) (xy 89.806253 74.264143) (xy 89.820395 74.25) (xy 90.179605 74.25) + (xy 91.135413 75.205808) (xy 91.399814 75.110044) (xy 91.540704 74.820429) (xy 91.622384 74.508892) (xy 91.641718 74.187405) + (xy 91.597961 73.868325) (xy 91.492795 73.563912) (xy 91.399814 73.389956) (xy 91.135413 73.294192) (xy 90.179605 74.25) + (xy 89.820395 74.25) (xy 89.806253 74.235858) (xy 89.985858 74.056253) (xy 90 74.070395) (xy 90.955808 73.114587) + (xy 90.860044 72.850186) (xy 90.570429 72.709296) (xy 90.258892 72.627616) (xy 89.937405 72.608282) (xy 89.618325 72.652039) + (xy 89.313912 72.757205) (xy 89.139956 72.850186) (xy 89.044193 73.114585) (xy 88.959493 73.029885) (xy 88.959049 48.922017) + (xy 90.77809 48.922017) (xy 90.819078 49.194133) (xy 90.912364 49.453023) (xy 90.974344 49.56898) (xy 91.214435 49.63596) + (xy 92.000395 48.85) (xy 91.214435 48.06404) (xy 90.974344 48.13102) (xy 90.857244 48.380048) (xy 90.790977 48.647135) + (xy 90.77809 48.922017) (xy 88.959049 48.922017) (xy 88.959003 46.382017) (xy 90.77809 46.382017) (xy 90.819078 46.654133) + (xy 90.912364 46.913023) (xy 90.974344 47.02898) (xy 91.214435 47.09596) (xy 92.000395 46.31) (xy 91.214435 45.52404) + (xy 90.974344 45.59102) (xy 90.857244 45.840048) (xy 90.790977 46.107135) (xy 90.77809 46.382017) (xy 88.959003 46.382017) + (xy 88.958857 38.511863) (xy 88.971894 38.382509) (xy 88.998593 38.296493) (xy 89.041067 38.218238) (xy 89.097851 38.149414) + (xy 89.16667 38.092633) (xy 89.244936 38.05015) (xy 89.33096 38.023445) (xy 89.473606 38.009063) (xy 149.013379 35.685) + (xy 170.896299 35.685) ) ) (filled_polygon @@ -11539,22 +11542,21 @@ (xy 106.797 125.132) (xy 106.777 125.132) (xy 106.777 125.152) (xy 106.523 125.152) (xy 106.523 125.132) (xy 105.17375 125.132) (xy 105.015 125.29075) (xy 105.011928 125.505) (xy 105.024188 125.629482) (xy 105.060498 125.74918) (xy 105.119463 125.859494) (xy 105.198815 125.956185) (xy 105.295138 126.035235) (xy 105.265099 126.107755) (xy 105.23301 126.269075) - (xy 105.23301 126.433555) (xy 105.265099 126.594875) (xy 105.308011 126.698474) (xy 105.30801 128.078378) (xy 105.306511 128.07084) - (xy 105.243567 127.918879) (xy 105.152187 127.782119) (xy 105.035881 127.665813) (xy 104.899121 127.574433) (xy 104.74716 127.511489) - (xy 104.671176 127.496375) (xy 104.283141 127.10834) (xy 104.259339 127.079337) (xy 104.143614 126.984364) (xy 104.011585 126.913792) - (xy 103.868324 126.870335) (xy 103.756671 126.859338) (xy 103.75666 126.859338) (xy 103.719338 126.855662) (xy 103.682016 126.859338) - (xy 101.607306 126.859338) (xy 101.543653 126.770509) (xy 101.452359 126.685003) (xy 101.346137 126.61895) (xy 101.22907 126.574889) - (xy 101.105657 126.554513) (xy 100.98064 126.558606) (xy 100.858824 126.587009) (xy 100.744889 126.638632) (xy 100.653371 126.69147) - (xy 100.621149 126.665026) (xy 100.48912 126.594454) (xy 100.345859 126.550997) (xy 100.234206 126.54) (xy 100.234195 126.54) - (xy 100.196873 126.536324) (xy 100.159551 126.54) (xy 99.349925 126.54) (xy 99.3126 126.536324) (xy 99.275275 126.54) - (xy 99.275267 126.54) (xy 99.219258 126.545517) (xy 99.157787 126.453519) (xy 99.041481 126.337213) (xy 98.904721 126.245833) - (xy 98.851156 126.223646) (xy 99.314803 125.76) (xy 100.827843 125.76) (xy 100.93144 125.802911) (xy 101.09276 125.835) - (xy 101.25724 125.835) (xy 101.41856 125.802911) (xy 101.570521 125.739967) (xy 101.707281 125.648587) (xy 101.823587 125.532281) - (xy 101.914967 125.395521) (xy 101.957879 125.291922) (xy 102.01373 125.236071) (xy 101.999179 125.28404) (xy 101.937089 125.43394) - (xy 101.905 125.59526) (xy 101.905 125.75974) (xy 101.937089 125.92106) (xy 102.000033 126.073021) (xy 102.091413 126.209781) - (xy 102.207719 126.326087) (xy 102.344479 126.417467) (xy 102.49644 126.480411) (xy 102.65776 126.5125) (xy 102.82224 126.5125) - (xy 102.98356 126.480411) (xy 103.135521 126.417467) (xy 103.272281 126.326087) (xy 103.388587 126.209781) (xy 103.479967 126.073021) - (xy 103.542911 125.92106) (xy 103.575 125.75974) (xy 103.575 125.699801) (xy 105.113913 124.160888) + (xy 105.23301 126.433555) (xy 105.265099 126.594875) (xy 105.308011 126.698474) (xy 105.308011 127.941947) (xy 105.243011 127.820341) + (xy 105.160132 127.719353) (xy 104.33093 126.890152) (xy 104.303213 126.856379) (xy 104.168455 126.745785) (xy 104.014709 126.663607) + (xy 103.847886 126.613001) (xy 103.717873 126.600196) (xy 103.717865 126.600196) (xy 103.674396 126.595915) (xy 103.630927 126.600196) + (xy 101.723224 126.600196) (xy 101.679755 126.595915) (xy 101.636286 126.600196) (xy 101.636278 126.600196) (xy 101.506265 126.613001) + (xy 101.39221 126.6476) (xy 101.346137 126.61895) (xy 101.22907 126.574889) (xy 101.105657 126.554513) (xy 100.98064 126.558606) + (xy 100.858824 126.587009) (xy 100.744889 126.638632) (xy 100.658784 126.688345) (xy 100.618762 126.676204) (xy 100.488749 126.663399) + (xy 100.488741 126.663399) (xy 100.445272 126.659118) (xy 100.401803 126.663399) (xy 99.279454 126.663399) (xy 99.249167 126.590279) + (xy 99.157787 126.453519) (xy 99.041481 126.337213) (xy 98.904721 126.245833) (xy 98.851156 126.223646) (xy 99.314803 125.76) + (xy 100.827843 125.76) (xy 100.93144 125.802911) (xy 101.09276 125.835) (xy 101.25724 125.835) (xy 101.41856 125.802911) + (xy 101.570521 125.739967) (xy 101.707281 125.648587) (xy 101.823587 125.532281) (xy 101.914967 125.395521) (xy 101.957879 125.291922) + (xy 102.01373 125.236071) (xy 101.999179 125.28404) (xy 101.937089 125.43394) (xy 101.905 125.59526) (xy 101.905 125.75974) + (xy 101.937089 125.92106) (xy 102.000033 126.073021) (xy 102.091413 126.209781) (xy 102.207719 126.326087) (xy 102.344479 126.417467) + (xy 102.49644 126.480411) (xy 102.65776 126.5125) (xy 102.82224 126.5125) (xy 102.98356 126.480411) (xy 103.135521 126.417467) + (xy 103.272281 126.326087) (xy 103.388587 126.209781) (xy 103.479967 126.073021) (xy 103.542911 125.92106) (xy 103.575 125.75974) + (xy 103.575 125.699801) (xy 105.113913 124.160888) ) ) (filled_polygon @@ -11569,8 +11571,9 @@ (xy 188.25 122.333072) (xy 188.374482 122.320812) (xy 188.49418 122.284502) (xy 188.604494 122.225537) (xy 188.701185 122.146185) (xy 188.780537 122.049494) (xy 188.839502 121.93918) (xy 188.875812 121.819482) (xy 188.888072 121.695) (xy 188.888072 121.139266) (xy 189.114392 120.912946) (xy 189.217989 120.870035) (xy 189.354749 120.778655) (xy 189.471055 120.662349) (xy 189.562435 120.525589) - (xy 189.625379 120.373628) (xy 189.657468 120.212308) (xy 189.657468 120.047828) (xy 189.644001 119.980127) (xy 189.663803 119.955998) - (xy 190.160268 119.459533) (xy 190.19356 119.452911) (xy 190.345521 119.389967) (xy 190.482281 119.298587) (xy 190.538401 119.242467) + (xy 189.625379 120.373628) (xy 189.657468 120.212308) (xy 189.657468 120.047828) (xy 189.625379 119.886508) (xy 189.562435 119.734547) + (xy 189.471055 119.597787) (xy 189.408268 119.535) (xy 189.993477 119.535) (xy 190.12349 119.522195) (xy 190.290313 119.471589) + (xy 190.444059 119.389411) (xy 190.538401 119.311986) ) ) (filled_polygon @@ -11580,7 +11583,7 @@ (xy 121.8976 121.65036) (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.972601 122.079759) (xy 121.9726 122.985443) (xy 121.929689 123.08904) (xy 121.8976 123.25036) (xy 121.8976 123.41484) (xy 121.929689 123.57616) (xy 121.9726 123.679757) (xy 121.9726 123.895278) (xy 121.968924 123.9326) (xy 121.9726 123.969922) (xy 121.9726 123.969932) (xy 121.983597 124.081585) - (xy 122.01936 124.199482) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.135493 124.403017) (xy 122.192599 124.472601) + (xy 122.01936 124.199482) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.132017 124.398781) (xy 122.192599 124.472601) (xy 122.221603 124.496404) (xy 122.436196 124.710997) (xy 122.459999 124.740001) (xy 122.575724 124.834974) (xy 122.707753 124.905546) (xy 122.762007 124.922004) (xy 122.771627 124.940001) (xy 120.62351 124.940001) (xy 120.635 124.88224) (xy 120.635 124.71776) (xy 120.602911 124.55644) (xy 120.539967 124.404479) (xy 120.448587 124.267719) (xy 120.332281 124.151413) (xy 120.195521 124.060033) @@ -11629,28 +11632,58 @@ ) (filled_polygon (pts - (xy 190.787398 118.39819) (xy 190.7584 118.421988) (xy 190.756471 118.424338) (xy 190.752911 118.40644) (xy 190.689967 118.254479) - (xy 190.598587 118.117719) (xy 190.482281 118.001413) (xy 190.345521 117.910033) (xy 190.19356 117.847089) (xy 190.03224 117.815) - (xy 189.86776 117.815) (xy 189.70644 117.847089) (xy 189.554479 117.910033) (xy 189.417719 118.001413) (xy 189.301413 118.117719) - (xy 189.210033 118.254479) (xy 189.206012 118.264186) (xy 188.815076 118.655123) (xy 188.780537 118.590506) (xy 188.701185 118.493815) - (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) (xy 188.25 118.306928) (xy 186.25 118.306928) - (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) (xy 185.798815 118.493815) (xy 185.719463 118.590506) - (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) (xy 185.611928 119.945) (xy 185.624188 120.069482) - (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) (xy 185.719463 120.340506) (xy 185.660498 120.45082) - (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.695) (xy 185.618822 121.764999) (xy 184.481178 121.764999) - (xy 184.488072 121.695) (xy 184.485 121.48075) (xy 184.32625 121.322) (xy 182.977 121.322) (xy 182.977 121.342) - (xy 182.723 121.342) (xy 182.723 121.322) (xy 181.37375 121.322) (xy 181.215 121.48075) (xy 181.211928 121.695) - (xy 181.218822 121.764999) (xy 180.154804 121.764999) (xy 179.592903 121.2031) (xy 179.62182 121.194328) (xy 179.745163 121.1284) - (xy 179.853275 121.039675) (xy 179.942 120.931563) (xy 180.007928 120.80822) (xy 180.048527 120.674384) (xy 180.0588 120.570077) - (xy 180.0588 120.570076) (xy 180.062235 120.5352) (xy 180.0588 120.500323) (xy 180.0588 120.31) (xy 180.127002 120.31) - (xy 180.127002 120.151252) (xy 180.278 120.30225) (xy 180.278 120.32604) (xy 180.310089 120.48736) (xy 180.373033 120.639321) - (xy 180.464413 120.776081) (xy 180.580719 120.892387) (xy 180.717479 120.983767) (xy 180.86944 121.046711) (xy 181.03076 121.0788) - (xy 181.19524 121.0788) (xy 181.353141 121.047391) (xy 181.37375 121.068) (xy 182.723 121.068) (xy 182.723 121.048) - (xy 182.977 121.048) (xy 182.977 121.068) (xy 184.32625 121.068) (xy 184.485 120.90925) (xy 184.488072 120.695) - (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) (xy 184.363708 120.32) (xy 184.380537 120.299494) - (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) (xy 184.488072 118.945) (xy 184.475812 118.820518) - (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) (xy 184.379711 118.35376) - (xy 184.403516 118.234088) (xy 185.418404 117.2192) (xy 191.966387 117.2192) + (xy 190.795867 118.389721) (xy 190.771589 118.309687) (xy 190.689411 118.155941) (xy 190.578817 118.021183) (xy 190.444059 117.910589) + (xy 190.290313 117.828411) (xy 190.12349 117.777805) (xy 189.993477 117.765) (xy 188.088469 117.765) (xy 188.045 117.760719) + (xy 188.001531 117.765) (xy 188.001523 117.765) (xy 187.87151 117.777805) (xy 187.704687 117.828411) (xy 187.613779 117.877002) + (xy 187.550941 117.910589) (xy 187.449953 117.993468) (xy 187.449951 117.99347) (xy 187.416183 118.021183) (xy 187.38847 118.054951) + (xy 187.136493 118.306928) (xy 186.25 118.306928) (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) + (xy 185.798815 118.493815) (xy 185.719463 118.590506) (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) + (xy 185.611928 119.945) (xy 185.624188 120.069482) (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) + (xy 185.719463 120.340506) (xy 185.660498 120.45082) (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.695) + (xy 185.618822 121.764999) (xy 184.481178 121.764999) (xy 184.488072 121.695) (xy 184.485 121.48075) (xy 184.32625 121.322) + (xy 182.977 121.322) (xy 182.977 121.342) (xy 182.723 121.342) (xy 182.723 121.322) (xy 181.37375 121.322) + (xy 181.215 121.48075) (xy 181.211928 121.695) (xy 181.218822 121.764999) (xy 180.154804 121.764999) (xy 179.592903 121.2031) + (xy 179.62182 121.194328) (xy 179.745163 121.1284) (xy 179.853275 121.039675) (xy 179.942 120.931563) (xy 180.007928 120.80822) + (xy 180.048527 120.674384) (xy 180.0588 120.570077) (xy 180.0588 120.570076) (xy 180.062235 120.5352) (xy 180.0588 120.500323) + (xy 180.0588 120.31) (xy 180.127002 120.31) (xy 180.127002 120.151252) (xy 180.278 120.30225) (xy 180.278 120.32604) + (xy 180.310089 120.48736) (xy 180.373033 120.639321) (xy 180.464413 120.776081) (xy 180.580719 120.892387) (xy 180.717479 120.983767) + (xy 180.86944 121.046711) (xy 181.03076 121.0788) (xy 181.19524 121.0788) (xy 181.353141 121.047391) (xy 181.37375 121.068) + (xy 182.723 121.068) (xy 182.723 121.048) (xy 182.977 121.048) (xy 182.977 121.068) (xy 184.32625 121.068) + (xy 184.485 120.90925) (xy 184.488072 120.695) (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) + (xy 184.363708 120.32) (xy 184.380537 120.299494) (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) + (xy 184.488072 118.945) (xy 184.475812 118.820518) (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) + (xy 184.316767 118.505721) (xy 184.379711 118.35376) (xy 184.403516 118.234088) (xy 185.418404 117.2192) (xy 191.966387 117.2192) + ) + ) + (filled_polygon + (pts + (xy 165.658073 112.848531) (xy 165.554475 112.891443) (xy 165.417715 112.982823) (xy 165.301409 113.099129) (xy 165.210029 113.235889) + (xy 165.147085 113.38785) (xy 165.114996 113.54917) (xy 165.114996 113.71365) (xy 165.147085 113.87497) (xy 165.210029 114.026931) + (xy 165.301409 114.163691) (xy 165.417715 114.279997) (xy 165.554475 114.371377) (xy 165.706436 114.434321) (xy 165.867756 114.46641) + (xy 166.032236 114.46641) (xy 166.193556 114.434321) (xy 166.345517 114.371377) (xy 166.482277 114.279997) (xy 166.598583 114.163691) + (xy 166.689963 114.026931) (xy 166.732875 113.923333) (xy 167.393715 113.262493) (xy 172.15127 118.020049) (xy 172.178983 118.053817) + (xy 172.313741 118.164411) (xy 172.467487 118.246589) (xy 172.63431 118.297195) (xy 172.764323 118.31) (xy 172.764331 118.31) + (xy 172.8078 118.314281) (xy 172.851269 118.31) (xy 172.9882 118.31) (xy 172.9882 118.37024) (xy 173.020289 118.53156) + (xy 173.083233 118.683521) (xy 173.174613 118.820281) (xy 173.290919 118.936587) (xy 173.427679 119.027967) (xy 173.57964 119.090911) + (xy 173.74096 119.123) (xy 173.761928 119.123) (xy 173.761928 119.675) (xy 173.774188 119.799482) (xy 173.810498 119.91918) + (xy 173.869463 120.029494) (xy 173.948815 120.126185) (xy 174.045506 120.205537) (xy 174.15582 120.264502) (xy 174.275518 120.300812) + (xy 174.4 120.313072) (xy 175.1388 120.313072) (xy 175.1388 120.500323) (xy 175.135365 120.5352) (xy 175.144387 120.6268) + (xy 173.884003 120.6268) (xy 171.661203 118.404002) (xy 171.6374 118.374998) (xy 171.521675 118.280025) (xy 171.389646 118.209453) + (xy 171.246385 118.165996) (xy 171.134732 118.154999) (xy 171.134721 118.154999) (xy 171.097399 118.151323) (xy 171.060077 118.154999) + (xy 161.052135 118.154999) (xy 161.063835 118.0362) (xy 161.0604 118.001323) (xy 161.0604 117.8) (xy 161.127002 117.8) + (xy 161.127002 117.641252) (xy 161.28575 117.8) (xy 161.8 117.803072) (xy 161.924482 117.790812) (xy 162.04418 117.754502) + (xy 162.154494 117.695537) (xy 162.251185 117.616185) (xy 162.330537 117.519494) (xy 162.389502 117.40918) (xy 162.425812 117.289482) + (xy 162.438072 117.165) (xy 162.435 116.95075) (xy 162.27625 116.792) (xy 161.127 116.792) (xy 161.127 116.812) + (xy 161.0604 116.812) (xy 161.0604 116.518) (xy 161.127 116.518) (xy 161.127 116.538) (xy 162.27625 116.538) + (xy 162.435 116.37925) (xy 162.438072 116.165) (xy 162.425812 116.040518) (xy 162.389502 115.92082) (xy 162.330537 115.810506) + (xy 162.313708 115.79) (xy 162.330537 115.769494) (xy 162.389502 115.65918) (xy 162.425812 115.539482) (xy 162.427882 115.518463) + (xy 162.505211 115.455001) (xy 162.529013 115.425998) (xy 162.785512 115.169499) (xy 162.88911 115.126588) (xy 163.02587 115.035208) + (xy 163.142176 114.918902) (xy 163.233556 114.782142) (xy 163.2965 114.630181) (xy 163.328589 114.468861) (xy 163.328589 114.304381) + (xy 163.2965 114.143061) (xy 163.233556 113.9911) (xy 163.142176 113.85434) (xy 163.02587 113.738034) (xy 162.88911 113.646654) + (xy 162.737149 113.58371) (xy 162.575829 113.551621) (xy 162.411349 113.551621) (xy 162.250029 113.58371) (xy 162.098068 113.646654) + (xy 161.961308 113.738034) (xy 161.911439 113.787903) (xy 161.8 113.776928) (xy 161.76 113.776928) (xy 161.76 113.223722) + (xy 161.763676 113.186399) (xy 161.76 113.149076) (xy 161.76 113.149067) (xy 161.749003 113.037414) (xy 161.705546 112.894153) + (xy 161.634974 112.762124) (xy 161.625032 112.75001) (xy 165.756595 112.75001) ) ) (filled_polygon @@ -11695,71 +11728,38 @@ (xy 112.367719 118.876434) (xy 112.251413 118.99274) (xy 112.160033 119.1295) (xy 112.097089 119.281461) (xy 112.065 119.442781) (xy 112.065 119.511728) (xy 111.5498 119.511728) (xy 111.425318 119.523988) (xy 111.30562 119.560298) (xy 111.195306 119.619263) (xy 111.098615 119.698615) (xy 111.019263 119.795306) (xy 110.960298 119.90562) (xy 110.923988 120.025318) (xy 110.911728 120.1498) - (xy 110.911728 120.233468) (xy 110.693076 120.45212) (xy 110.639978 120.474114) (xy 110.630994 120.474999) (xy 110.630985 120.474999) - (xy 110.519332 120.485996) (xy 110.376071 120.529453) (xy 110.244042 120.600025) (xy 110.128317 120.694998) (xy 110.104519 120.723996) - (xy 109.937872 120.890643) (xy 109.937872 120.482188) (xy 110.044581 120.410887) (xy 110.160887 120.294581) (xy 110.252267 120.157821) - (xy 110.295178 120.054224) (xy 110.511003 119.838399) (xy 110.540001 119.814601) (xy 110.581828 119.763635) (xy 110.634974 119.698877) - (xy 110.705546 119.566847) (xy 110.718001 119.525788) (xy 110.749003 119.423586) (xy 110.76 119.311933) (xy 110.76 119.311924) - (xy 110.763676 119.274601) (xy 110.76 119.237278) (xy 110.76 102.037323) (xy 110.763676 102) (xy 110.76 101.962677) - (xy 110.76 101.962667) (xy 110.749003 101.851014) (xy 110.705546 101.707753) (xy 110.634974 101.575724) (xy 110.540001 101.459999) - (xy 110.511004 101.436202) (xy 109.399802 100.325) (xy 110.886928 100.325) (xy 110.886928 101.625) (xy 110.899188 101.749482) - (xy 110.935498 101.86918) (xy 110.994463 101.979494) (xy 111.073815 102.076185) (xy 111.167863 102.153368) (xy 111.165 102.16776) - (xy 111.165 102.33224) (xy 111.197089 102.49356) (xy 111.260033 102.645521) (xy 111.329844 102.75) (xy 111.260033 102.854479) - (xy 111.197089 103.00644) (xy 111.165 103.16776) (xy 111.165 103.33224) (xy 111.167863 103.346632) (xy 111.073815 103.423815) - (xy 110.994463 103.520506) (xy 110.935498 103.63082) (xy 110.899188 103.750518) (xy 110.886928 103.875) (xy 110.886928 105.175) - (xy 110.899188 105.299482) (xy 110.935498 105.41918) (xy 110.994463 105.529494) (xy 111.073815 105.626185) (xy 111.170506 105.705537) - (xy 111.28082 105.764502) (xy 111.400518 105.800812) (xy 111.525 105.813072) (xy 112.475 105.813072) (xy 112.599482 105.800812) - (xy 112.71918 105.764502) (xy 112.829494 105.705537) (xy 112.926185 105.626185) (xy 113.005537 105.529494) (xy 113.064502 105.41918) - (xy 113.100812 105.299482) (xy 113.113072 105.175) (xy 113.113072 103.875) (xy 113.100812 103.750518) (xy 113.064502 103.63082) - (xy 113.005537 103.520506) (xy 112.926185 103.423815) (xy 112.832137 103.346632) (xy 112.835 103.33224) (xy 112.835 103.16776) - (xy 112.802911 103.00644) (xy 112.739967 102.854479) (xy 112.670156 102.75) (xy 112.739967 102.645521) (xy 112.802911 102.49356) - (xy 112.835 102.33224) (xy 112.835 102.16776) (xy 112.832137 102.153368) (xy 112.926185 102.076185) (xy 113.005537 101.979494) - (xy 113.064502 101.86918) (xy 113.100812 101.749482) (xy 113.113072 101.625) (xy 113.113072 100.325) (xy 113.100812 100.200518) - (xy 113.064502 100.08082) (xy 113.005537 99.970506) (xy 112.926185 99.873815) (xy 112.829494 99.794463) (xy 112.71918 99.735498) - (xy 112.599482 99.699188) (xy 112.475 99.686928) (xy 111.525 99.686928) (xy 111.400518 99.699188) (xy 111.28082 99.735498) - (xy 111.170506 99.794463) (xy 111.073815 99.873815) (xy 110.994463 99.970506) (xy 110.935498 100.08082) (xy 110.899188 100.200518) - (xy 110.886928 100.325) (xy 109.399802 100.325) (xy 107.682825 98.608024) (xy 107.69276 98.61) (xy 107.85724 98.61) - (xy 108.01856 98.577911) (xy 108.170521 98.514967) (xy 108.307281 98.423587) (xy 108.423587 98.307281) (xy 108.514967 98.170521) - (xy 108.538763 98.113072) (xy 109.425 98.113072) (xy 109.549482 98.100812) (xy 109.66918 98.064502) (xy 109.779494 98.005537) - (xy 109.876185 97.926185) (xy 109.955537 97.829494) (xy 110.014502 97.71918) (xy 110.033093 97.657894) (xy 110.638835 98.263637) - (xy 110.701414 98.357293) (xy 110.81772 98.473599) (xy 110.95448 98.564979) (xy 111.106441 98.627923) (xy 111.267761 98.660012) - (xy 111.432241 98.660012) (xy 111.593561 98.627923) (xy 111.745522 98.564979) (xy 111.882282 98.473599) (xy 111.998588 98.357293) - (xy 112.089968 98.220533) (xy 112.152912 98.068572) (xy 112.185001 97.907252) (xy 112.185001 97.742772) (xy 112.152912 97.581452) - (xy 112.089968 97.429491) (xy 111.998588 97.292731) (xy 111.882282 97.176425) (xy 111.745522 97.085045) (xy 111.593561 97.022101) - (xy 111.535317 97.010515) (xy 111.01 96.485199) (xy 111.01 90.554616) (xy 111.01857 90.552911) (xy 111.170531 90.489967) - (xy 111.307291 90.398587) (xy 111.423597 90.282281) (xy 111.514977 90.145521) (xy 111.561375 90.033506) (xy 111.609983 89.974277) - (xy 111.680555 89.842248) (xy 111.711928 89.738823) - ) - ) - (filled_polygon - (pts - (xy 165.658073 112.848531) (xy 165.554475 112.891443) (xy 165.417715 112.982823) (xy 165.301409 113.099129) (xy 165.210029 113.235889) - (xy 165.147085 113.38785) (xy 165.114996 113.54917) (xy 165.114996 113.71365) (xy 165.147085 113.87497) (xy 165.210029 114.026931) - (xy 165.301409 114.163691) (xy 165.417715 114.279997) (xy 165.554475 114.371377) (xy 165.706436 114.434321) (xy 165.867756 114.46641) - (xy 166.032236 114.46641) (xy 166.193556 114.434321) (xy 166.345517 114.371377) (xy 166.482277 114.279997) (xy 166.598583 114.163691) - (xy 166.689963 114.026931) (xy 166.732875 113.923333) (xy 167.482103 113.174104) (xy 171.998922 117.690924) (xy 172.041833 117.794521) - (xy 172.133213 117.931281) (xy 172.249519 118.047587) (xy 172.386279 118.138967) (xy 172.53824 118.201911) (xy 172.69956 118.234) - (xy 172.86404 118.234) (xy 172.9882 118.209303) (xy 172.9882 118.37024) (xy 173.020289 118.53156) (xy 173.083233 118.683521) - (xy 173.174613 118.820281) (xy 173.290919 118.936587) (xy 173.427679 119.027967) (xy 173.57964 119.090911) (xy 173.74096 119.123) - (xy 173.761928 119.123) (xy 173.761928 119.675) (xy 173.774188 119.799482) (xy 173.810498 119.91918) (xy 173.869463 120.029494) - (xy 173.948815 120.126185) (xy 174.045506 120.205537) (xy 174.15582 120.264502) (xy 174.275518 120.300812) (xy 174.4 120.313072) - (xy 175.1388 120.313072) (xy 175.1388 120.500323) (xy 175.135365 120.5352) (xy 175.144387 120.6268) (xy 173.884003 120.6268) - (xy 171.661203 118.404002) (xy 171.6374 118.374998) (xy 171.521675 118.280025) (xy 171.389646 118.209453) (xy 171.246385 118.165996) - (xy 171.134732 118.154999) (xy 171.134721 118.154999) (xy 171.097399 118.151323) (xy 171.060077 118.154999) (xy 161.052135 118.154999) - (xy 161.063835 118.0362) (xy 161.0604 118.001323) (xy 161.0604 117.8) (xy 161.127002 117.8) (xy 161.127002 117.641252) - (xy 161.28575 117.8) (xy 161.8 117.803072) (xy 161.924482 117.790812) (xy 162.04418 117.754502) (xy 162.154494 117.695537) - (xy 162.251185 117.616185) (xy 162.330537 117.519494) (xy 162.389502 117.40918) (xy 162.425812 117.289482) (xy 162.438072 117.165) - (xy 162.435 116.95075) (xy 162.27625 116.792) (xy 161.127 116.792) (xy 161.127 116.812) (xy 161.0604 116.812) - (xy 161.0604 116.518) (xy 161.127 116.518) (xy 161.127 116.538) (xy 162.27625 116.538) (xy 162.435 116.37925) - (xy 162.438072 116.165) (xy 162.425812 116.040518) (xy 162.389502 115.92082) (xy 162.330537 115.810506) (xy 162.313708 115.79) - (xy 162.330537 115.769494) (xy 162.389502 115.65918) (xy 162.425812 115.539482) (xy 162.427882 115.518463) (xy 162.505211 115.455001) - (xy 162.529013 115.425998) (xy 162.785512 115.169499) (xy 162.88911 115.126588) (xy 163.02587 115.035208) (xy 163.142176 114.918902) - (xy 163.233556 114.782142) (xy 163.2965 114.630181) (xy 163.328589 114.468861) (xy 163.328589 114.304381) (xy 163.2965 114.143061) - (xy 163.233556 113.9911) (xy 163.142176 113.85434) (xy 163.02587 113.738034) (xy 162.88911 113.646654) (xy 162.737149 113.58371) - (xy 162.575829 113.551621) (xy 162.411349 113.551621) (xy 162.250029 113.58371) (xy 162.098068 113.646654) (xy 161.961308 113.738034) - (xy 161.911439 113.787903) (xy 161.8 113.776928) (xy 161.76 113.776928) (xy 161.76 113.223722) (xy 161.763676 113.186399) - (xy 161.76 113.149076) (xy 161.76 113.149067) (xy 161.749003 113.037414) (xy 161.705546 112.894153) (xy 161.634974 112.762124) - (xy 161.625032 112.75001) (xy 165.756595 112.75001) + (xy 110.911728 120.233468) (xy 110.693076 120.45212) (xy 110.637842 120.474999) (xy 109.94863 120.474999) (xy 110.044581 120.410887) + (xy 110.160887 120.294581) (xy 110.252267 120.157821) (xy 110.295178 120.054224) (xy 110.511003 119.838399) (xy 110.540001 119.814601) + (xy 110.581828 119.763635) (xy 110.634974 119.698877) (xy 110.705546 119.566847) (xy 110.714219 119.538254) (xy 110.749003 119.423586) + (xy 110.76 119.311933) (xy 110.76 119.311924) (xy 110.763676 119.274601) (xy 110.76 119.237278) (xy 110.76 102.037323) + (xy 110.763676 102) (xy 110.76 101.962677) (xy 110.76 101.962667) (xy 110.749003 101.851014) (xy 110.705546 101.707753) + (xy 110.634974 101.575724) (xy 110.540001 101.459999) (xy 110.511004 101.436202) (xy 109.399802 100.325) (xy 110.886928 100.325) + (xy 110.886928 101.625) (xy 110.899188 101.749482) (xy 110.935498 101.86918) (xy 110.994463 101.979494) (xy 111.073815 102.076185) + (xy 111.167863 102.153368) (xy 111.165 102.16776) (xy 111.165 102.33224) (xy 111.197089 102.49356) (xy 111.260033 102.645521) + (xy 111.329844 102.75) (xy 111.260033 102.854479) (xy 111.197089 103.00644) (xy 111.165 103.16776) (xy 111.165 103.33224) + (xy 111.167863 103.346632) (xy 111.073815 103.423815) (xy 110.994463 103.520506) (xy 110.935498 103.63082) (xy 110.899188 103.750518) + (xy 110.886928 103.875) (xy 110.886928 105.175) (xy 110.899188 105.299482) (xy 110.935498 105.41918) (xy 110.994463 105.529494) + (xy 111.073815 105.626185) (xy 111.170506 105.705537) (xy 111.28082 105.764502) (xy 111.400518 105.800812) (xy 111.525 105.813072) + (xy 112.475 105.813072) (xy 112.599482 105.800812) (xy 112.71918 105.764502) (xy 112.829494 105.705537) (xy 112.926185 105.626185) + (xy 113.005537 105.529494) (xy 113.064502 105.41918) (xy 113.100812 105.299482) (xy 113.113072 105.175) (xy 113.113072 103.875) + (xy 113.100812 103.750518) (xy 113.064502 103.63082) (xy 113.005537 103.520506) (xy 112.926185 103.423815) (xy 112.832137 103.346632) + (xy 112.835 103.33224) (xy 112.835 103.16776) (xy 112.802911 103.00644) (xy 112.739967 102.854479) (xy 112.670156 102.75) + (xy 112.739967 102.645521) (xy 112.802911 102.49356) (xy 112.835 102.33224) (xy 112.835 102.16776) (xy 112.832137 102.153368) + (xy 112.926185 102.076185) (xy 113.005537 101.979494) (xy 113.064502 101.86918) (xy 113.100812 101.749482) (xy 113.113072 101.625) + (xy 113.113072 100.325) (xy 113.100812 100.200518) (xy 113.064502 100.08082) (xy 113.005537 99.970506) (xy 112.926185 99.873815) + (xy 112.829494 99.794463) (xy 112.71918 99.735498) (xy 112.599482 99.699188) (xy 112.475 99.686928) (xy 111.525 99.686928) + (xy 111.400518 99.699188) (xy 111.28082 99.735498) (xy 111.170506 99.794463) (xy 111.073815 99.873815) (xy 110.994463 99.970506) + (xy 110.935498 100.08082) (xy 110.899188 100.200518) (xy 110.886928 100.325) (xy 109.399802 100.325) (xy 107.682825 98.608024) + (xy 107.69276 98.61) (xy 107.85724 98.61) (xy 108.01856 98.577911) (xy 108.170521 98.514967) (xy 108.307281 98.423587) + (xy 108.423587 98.307281) (xy 108.514967 98.170521) (xy 108.538763 98.113072) (xy 109.425 98.113072) (xy 109.549482 98.100812) + (xy 109.66918 98.064502) (xy 109.779494 98.005537) (xy 109.876185 97.926185) (xy 109.955537 97.829494) (xy 110.014502 97.71918) + (xy 110.033093 97.657894) (xy 110.638835 98.263637) (xy 110.701414 98.357293) (xy 110.81772 98.473599) (xy 110.95448 98.564979) + (xy 111.106441 98.627923) (xy 111.267761 98.660012) (xy 111.432241 98.660012) (xy 111.593561 98.627923) (xy 111.745522 98.564979) + (xy 111.882282 98.473599) (xy 111.998588 98.357293) (xy 112.089968 98.220533) (xy 112.152912 98.068572) (xy 112.185001 97.907252) + (xy 112.185001 97.742772) (xy 112.152912 97.581452) (xy 112.089968 97.429491) (xy 111.998588 97.292731) (xy 111.882282 97.176425) + (xy 111.745522 97.085045) (xy 111.593561 97.022101) (xy 111.535317 97.010515) (xy 111.01 96.485199) (xy 111.01 90.554616) + (xy 111.01857 90.552911) (xy 111.170531 90.489967) (xy 111.307291 90.398587) (xy 111.423597 90.282281) (xy 111.514977 90.145521) + (xy 111.561375 90.033506) (xy 111.609983 89.974277) (xy 111.680555 89.842248) (xy 111.711928 89.738823) ) ) (filled_polygon @@ -11773,21 +11773,19 @@ ) (filled_polygon (pts - (xy 129.628319 116.066387) (xy 129.765079 116.157767) (xy 129.91704 116.220711) (xy 130.07836 116.2528) (xy 130.24284 116.2528) - (xy 130.40416 116.220711) (xy 130.507757 116.1778) (xy 132.493799 116.1778) (xy 134.336599 118.020601) (xy 134.336599 118.137941) - (xy 134.332923 118.175263) (xy 134.336599 118.212585) (xy 134.336599 118.212596) (xy 134.347596 118.324249) (xy 134.391053 118.46751) - (xy 134.461625 118.599539) (xy 134.556599 118.715264) (xy 134.585597 118.739062) (xy 134.88659 119.040055) (xy 134.929501 119.143653) - (xy 135.020881 119.280413) (xy 135.137187 119.396719) (xy 135.273947 119.488099) (xy 135.425908 119.551043) (xy 135.587228 119.583132) - (xy 135.662729 119.583132) (xy 135.674188 119.699482) (xy 135.710498 119.81918) (xy 135.769463 119.929494) (xy 135.848815 120.026185) - (xy 135.945506 120.105537) (xy 136.017838 120.1442) (xy 130.881802 120.1442) (xy 129.465679 118.728078) (xy 129.422767 118.624479) - (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) (xy 128.92636 118.217089) (xy 128.76504 118.185) - (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) (xy 128.47418 117.955498) (xy 128.354482 117.919188) - (xy 128.23 117.906928) (xy 127.696267 117.906928) (xy 129.582564 116.020632) + (xy 129.426941 116.411011) (xy 129.580687 116.493189) (xy 129.74751 116.543795) (xy 129.877523 116.5566) (xy 132.018222 116.5566) + (xy 134.31507 118.853449) (xy 134.342782 118.887216) (xy 134.37655 118.914929) (xy 134.812353 119.350732) (xy 134.913341 119.433611) + (xy 134.953358 119.455) (xy 135.067086 119.515789) (xy 135.187383 119.552281) (xy 135.233909 119.566395) (xy 135.4074 119.583481) + (xy 135.58089 119.566395) (xy 135.661928 119.541812) (xy 135.661928 119.575) (xy 135.674188 119.699482) (xy 135.710498 119.81918) + (xy 135.769463 119.929494) (xy 135.848815 120.026185) (xy 135.945506 120.105537) (xy 136.017838 120.1442) (xy 130.881802 120.1442) + (xy 129.465679 118.728078) (xy 129.422767 118.624479) (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) + (xy 128.92636 118.217089) (xy 128.76504 118.185) (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) + (xy 128.47418 117.955498) (xy 128.354482 117.919188) (xy 128.23 117.906928) (xy 127.696267 117.906928) (xy 129.298003 116.305193) ) ) (filled_polygon (pts - (xy 150.544189 115.771742) (xy 150.462011 115.925488) (xy 150.428813 116.034924) (xy 150.417814 116.071185) (xy 150.411405 116.092311) + (xy 150.544189 115.771742) (xy 150.462011 115.925488) (xy 150.428813 116.034924) (xy 150.411405 116.09231) (xy 150.411197 116.094418) (xy 150.3986 116.222324) (xy 150.3986 116.222331) (xy 150.395922 116.249528) (xy 150.2836 116.249528) (xy 150.159118 116.261788) (xy 150.03942 116.298098) (xy 149.929106 116.357063) (xy 149.832415 116.436415) (xy 149.753063 116.533106) (xy 149.694098 116.64342) (xy 149.657788 116.763118) (xy 149.645528 116.8876) (xy 149.645528 117.8876) (xy 149.657788 118.012082) (xy 149.694098 118.13178) @@ -11848,11 +11846,12 @@ (xy 140.505154 115.2392) (xy 137.785277 115.2392) (xy 137.7504 115.235765) (xy 137.715523 115.2392) (xy 137.611216 115.249473) (xy 137.47738 115.290072) (xy 137.354037 115.356) (xy 137.245925 115.444725) (xy 137.1572 115.552837) (xy 137.091272 115.67618) (xy 137.050673 115.810016) (xy 137.036965 115.9492) (xy 137.040401 115.984087) (xy 137.040401 116.186928) (xy 136.3 116.186928) - (xy 136.175518 116.199188) (xy 136.05582 116.235498) (xy 135.945506 116.294463) (xy 135.848815 116.373815) (xy 135.769463 116.470506) - (xy 135.718954 116.565) (xy 135.51472 116.565) (xy 135.477397 116.561324) (xy 135.440074 116.565) (xy 135.440065 116.565) - (xy 135.328412 116.575997) (xy 135.185151 116.619454) (xy 135.119922 116.65432) (xy 134.1184 115.652799) (xy 135.499679 115.652799) - (xy 135.537001 115.656475) (xy 135.574323 115.652799) (xy 135.574334 115.652799) (xy 135.685987 115.641802) (xy 135.829248 115.598345) - (xy 135.961277 115.527773) (xy 136.077002 115.4328) (xy 136.100804 115.403797) (xy 136.292001 115.2126) (xy 140.499863 115.2126) + (xy 136.175518 116.199188) (xy 136.05582 116.235498) (xy 135.945506 116.294463) (xy 135.848815 116.373815) (xy 135.808615 116.422799) + (xy 135.353064 116.422799) (xy 135.309598 116.418518) (xy 135.266132 116.422799) (xy 135.266122 116.422799) (xy 135.136109 116.435604) + (xy 134.969286 116.48621) (xy 134.81554 116.568388) (xy 134.680782 116.678982) (xy 134.664094 116.699316) (xy 133.617577 115.652799) + (xy 135.499679 115.652799) (xy 135.537001 115.656475) (xy 135.574323 115.652799) (xy 135.574334 115.652799) (xy 135.685987 115.641802) + (xy 135.829248 115.598345) (xy 135.961277 115.527773) (xy 136.077002 115.4328) (xy 136.100804 115.403797) (xy 136.292001 115.2126) + (xy 140.499863 115.2126) ) ) (filled_polygon @@ -11869,17 +11868,16 @@ (xy 175.786999 114.166599) (xy 175.763201 114.195597) (xy 174.908077 115.050721) (xy 174.804479 115.093633) (xy 174.667719 115.185013) (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) (xy 174.365 115.75136) (xy 174.365 115.91584) (xy 174.397089 116.07716) (xy 174.460033 116.229121) (xy 174.498658 116.286928) (xy 174.4 116.286928) (xy 174.275518 116.299188) - (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.869463 116.570506) (xy 173.832852 116.639) - (xy 173.128957 116.639) (xy 173.073724 116.616122) (xy 172.423536 115.965934) (xy 172.501281 115.913987) (xy 172.617587 115.797681) - (xy 172.708967 115.660921) (xy 172.751879 115.557322) (xy 174.290992 114.01821) (xy 174.31999 113.994412) (xy 174.414963 113.878687) - (xy 174.485535 113.746658) (xy 174.528992 113.603397) (xy 174.539989 113.491744) (xy 174.539989 113.491735) (xy 174.543665 113.454412) - (xy 174.539989 113.417089) (xy 174.539989 111.972157) (xy 174.5829 111.86856) (xy 174.584169 111.862178) (xy 174.849721 111.915) - (xy 175.270279 111.915) (xy 175.682756 111.832953) (xy 176.071302 111.672012) (xy 176.420983 111.438363) (xy 176.718363 111.140983) - (xy 176.952012 110.791302) (xy 177.112953 110.402756) (xy 177.195 109.990279) (xy 177.195 109.569721) (xy 177.112953 109.157244) - (xy 176.952012 108.768698) (xy 176.718363 108.419017) (xy 176.420983 108.121637) (xy 176.071302 107.887988) (xy 175.855698 107.798682) - (xy 175.925 107.45028) (xy 175.925 107.029722) (xy 175.873463 106.770627) (xy 175.888412 106.785576) (xy 176.328175 107.079417) - (xy 176.816814 107.281817) (xy 177.335551 107.385) (xy 177.864449 107.385) (xy 178.383186 107.281817) (xy 178.871825 107.079417) - (xy 179.311588 106.785576) (xy 179.326537 106.770627) + (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.894499 116.54) (xy 173.174379 116.54) + (xy 172.524823 115.890445) (xy 172.617587 115.797681) (xy 172.708967 115.660921) (xy 172.751879 115.557322) (xy 174.290992 114.01821) + (xy 174.31999 113.994412) (xy 174.414963 113.878687) (xy 174.485535 113.746658) (xy 174.528992 113.603397) (xy 174.539989 113.491744) + (xy 174.539989 113.491735) (xy 174.543665 113.454412) (xy 174.539989 113.417089) (xy 174.539989 111.972157) (xy 174.5829 111.86856) + (xy 174.584169 111.862178) (xy 174.849721 111.915) (xy 175.270279 111.915) (xy 175.682756 111.832953) (xy 176.071302 111.672012) + (xy 176.420983 111.438363) (xy 176.718363 111.140983) (xy 176.952012 110.791302) (xy 177.112953 110.402756) (xy 177.195 109.990279) + (xy 177.195 109.569721) (xy 177.112953 109.157244) (xy 176.952012 108.768698) (xy 176.718363 108.419017) (xy 176.420983 108.121637) + (xy 176.071302 107.887988) (xy 175.855698 107.798682) (xy 175.925 107.45028) (xy 175.925 107.029722) (xy 175.873463 106.770627) + (xy 175.888412 106.785576) (xy 176.328175 107.079417) (xy 176.816814 107.281817) (xy 177.335551 107.385) (xy 177.864449 107.385) + (xy 178.383186 107.281817) (xy 178.871825 107.079417) (xy 179.311588 106.785576) (xy 179.326537 106.770627) ) ) (filled_polygon @@ -11898,10 +11896,10 @@ (xy 172.994302 109.221319) (xy 172.925 109.569721) (xy 172.925 109.990279) (xy 173.007047 110.402756) (xy 173.167988 110.791302) (xy 173.278104 110.956103) (xy 173.247708 110.976413) (xy 173.131402 111.092719) (xy 173.040022 111.229479) (xy 172.977078 111.38144) (xy 172.944989 111.54276) (xy 172.944989 111.70724) (xy 172.977078 111.86856) (xy 173.019989 111.972157) (xy 173.01999 113.139608) - (xy 171.677078 114.482521) (xy 171.573479 114.525433) (xy 171.436719 114.616813) (xy 171.320413 114.733119) (xy 171.268466 114.810864) - (xy 168.593614 112.136013) (xy 168.606311 112.10536) (xy 168.6384 111.94404) (xy 168.6384 111.77956) (xy 168.606311 111.61824) - (xy 168.543367 111.466279) (xy 168.451987 111.329519) (xy 168.335681 111.213213) (xy 168.198921 111.121833) (xy 168.04696 111.058889) - (xy 167.88564 111.0268) (xy 167.76 111.0268) (xy 167.76 104.779799) (xy 168.136928 104.402872) + (xy 171.677078 114.482521) (xy 171.573479 114.525433) (xy 171.436719 114.616813) (xy 171.343955 114.709577) (xy 168.6884 112.054022) + (xy 168.6884 111.818323) (xy 168.675595 111.68831) (xy 168.624989 111.521487) (xy 168.542811 111.367741) (xy 168.432217 111.232983) + (xy 168.297459 111.122389) (xy 168.143713 111.040211) (xy 167.97689 110.989605) (xy 167.8034 110.972518) (xy 167.76 110.976792) + (xy 167.76 104.779799) (xy 168.136928 104.402872) ) ) (filled_polygon @@ -12371,27 +12369,27 @@ ) (filled_polygon (pts - (xy 127.115 102.268079) (xy 127.115 106.692528) (xy 127.104089 106.637673) (xy 126.984609 106.349221) (xy 126.81115 106.089621) - (xy 126.590379 105.86885) (xy 126.330779 105.695391) (xy 126.042327 105.575911) (xy 125.736109 105.515) (xy 125.423891 105.515) - (xy 125.117673 105.575911) (xy 125.023303 105.615) (xy 124.85374 105.615) (xy 124.566842 105.672068) (xy 124.296589 105.78401) - (xy 124.053368 105.946525) (xy 123.846525 106.153368) (xy 123.68401 106.396589) (xy 123.572068 106.666842) (xy 123.515 106.95374) - (xy 123.515 107.24626) (xy 123.572068 107.533158) (xy 123.607988 107.619876) (xy 123.298698 107.747988) (xy 123.076252 107.896622) - (xy 123.081817 107.883186) (xy 123.185 107.364449) (xy 123.185 106.835551) (xy 123.081817 106.316814) (xy 122.879417 105.828175) - (xy 122.585576 105.388412) (xy 122.211588 105.014424) (xy 121.771825 104.720583) (xy 121.384142 104.56) (xy 122.215123 104.56) - (xy 122.25 104.563435) (xy 122.284877 104.56) (xy 122.389184 104.549727) (xy 122.52302 104.509128) (xy 122.646363 104.4432) - (xy 122.754475 104.354475) (xy 122.8432 104.246363) (xy 122.909128 104.12302) (xy 122.949727 103.989184) (xy 122.963435 103.85) - (xy 122.96 103.815123) (xy 122.96 103.61) (xy 123.027002 103.61) (xy 123.027002 103.451252) (xy 123.18575 103.61) - (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) (xy 124.151185 103.426185) - (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) (xy 124.335 102.76075) - (xy 124.17625 102.602) (xy 123.027 102.602) (xy 123.027 102.622) (xy 122.96 102.622) (xy 122.96 102.328) - (xy 123.027 102.328) (xy 123.027 102.348) (xy 124.17625 102.348) (xy 124.218867 102.305383) (xy 124.36776 102.335) - (xy 124.53224 102.335) (xy 124.69356 102.302911) (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) - (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) - (xy 125.207568 101.146971) (xy 125.199003 101.060014) (xy 125.155546 100.916753) (xy 125.084974 100.784724) (xy 124.990001 100.668999) - (xy 124.960998 100.645197) (xy 124.529804 100.214003) (xy 124.506001 100.184999) (xy 124.390276 100.090026) (xy 124.309538 100.04687) - (xy 124.289502 99.98082) (xy 124.230537 99.870506) (xy 124.151185 99.773815) (xy 124.054494 99.694463) (xy 123.94418 99.635498) - (xy 123.824482 99.599188) (xy 123.7 99.586928) (xy 122.96 99.586928) (xy 122.96 99.384877) (xy 122.963435 99.35) - (xy 122.957033 99.285) (xy 124.131922 99.285) + (xy 126.970103 102.123182) (xy 126.970109 102.123187) (xy 127.140001 102.293079) (xy 127.140001 106.818211) (xy 127.104089 106.637673) + (xy 126.984609 106.349221) (xy 126.81115 106.089621) (xy 126.590379 105.86885) (xy 126.330779 105.695391) (xy 126.042327 105.575911) + (xy 125.736109 105.515) (xy 125.423891 105.515) (xy 125.117673 105.575911) (xy 125.023303 105.615) (xy 124.85374 105.615) + (xy 124.566842 105.672068) (xy 124.296589 105.78401) (xy 124.053368 105.946525) (xy 123.846525 106.153368) (xy 123.68401 106.396589) + (xy 123.572068 106.666842) (xy 123.515 106.95374) (xy 123.515 107.24626) (xy 123.572068 107.533158) (xy 123.607988 107.619876) + (xy 123.298698 107.747988) (xy 123.076252 107.896622) (xy 123.081817 107.883186) (xy 123.185 107.364449) (xy 123.185 106.835551) + (xy 123.081817 106.316814) (xy 122.879417 105.828175) (xy 122.585576 105.388412) (xy 122.211588 105.014424) (xy 121.771825 104.720583) + (xy 121.384142 104.56) (xy 122.215123 104.56) (xy 122.25 104.563435) (xy 122.284877 104.56) (xy 122.389184 104.549727) + (xy 122.52302 104.509128) (xy 122.646363 104.4432) (xy 122.754475 104.354475) (xy 122.8432 104.246363) (xy 122.909128 104.12302) + (xy 122.949727 103.989184) (xy 122.963435 103.85) (xy 122.96 103.815123) (xy 122.96 103.61) (xy 123.027002 103.61) + (xy 123.027002 103.451252) (xy 123.18575 103.61) (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) + (xy 124.054494 103.505537) (xy 124.151185 103.426185) (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) + (xy 124.338072 102.975) (xy 124.335 102.76075) (xy 124.17625 102.602) (xy 123.027 102.602) (xy 123.027 102.622) + (xy 122.96 102.622) (xy 122.96 102.328) (xy 123.027 102.328) (xy 123.027 102.348) (xy 124.17625 102.348) + (xy 124.218867 102.305383) (xy 124.36776 102.335) (xy 124.53224 102.335) (xy 124.69356 102.302911) (xy 124.845521 102.239967) + (xy 124.982281 102.148587) (xy 125.098587 102.032281) (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) + (xy 125.285 101.41776) (xy 125.252911 101.25644) (xy 125.207568 101.146971) (xy 125.199003 101.060014) (xy 125.155546 100.916753) + (xy 125.084974 100.784724) (xy 124.990001 100.668999) (xy 124.960998 100.645197) (xy 124.529804 100.214003) (xy 124.506001 100.184999) + (xy 124.390276 100.090026) (xy 124.309538 100.04687) (xy 124.289502 99.98082) (xy 124.230537 99.870506) (xy 124.151185 99.773815) + (xy 124.054494 99.694463) (xy 123.94418 99.635498) (xy 123.824482 99.599188) (xy 123.7 99.586928) (xy 122.96 99.586928) + (xy 122.96 99.384877) (xy 122.963435 99.35) (xy 122.957033 99.285) (xy 124.131922 99.285) ) ) (filled_polygon @@ -12685,18 +12683,18 @@ (pts (xy 130 94.49728) (xy 130.043477 94.492998) (xy 131.24142 94.492998) (xy 134.115 97.366579) (xy 134.115001 98.373674) (xy 134.115 98.373682) (xy 134.115 98.373689) (xy 134.110719 98.417158) (xy 134.115 98.460627) (xy 134.115 99.243481) - (xy 134.127805 99.373494) (xy 134.169523 99.511014) (xy 134.178412 99.540317) (xy 134.26059 99.694063) (xy 134.371184 99.828821) - (xy 134.505942 99.939415) (xy 134.659688 100.021593) (xy 134.826511 100.072199) (xy 135 100.089286) (xy 135.08523 100.080892) - (xy 135.12373 100.127804) (xy 135.16001 100.172011) (xy 135.189008 100.195809) (xy 135.479196 100.485997) (xy 135.502999 100.515001) - (xy 135.618724 100.609974) (xy 135.667965 100.636294) (xy 135.674188 100.699482) (xy 135.710498 100.81918) (xy 135.769463 100.929494) - (xy 135.848815 101.026185) (xy 135.910165 101.076533) (xy 134.378292 102.608407) (xy 131.777354 102.608407) (xy 131.829494 102.580537) - (xy 131.926185 102.501185) (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) - (xy 132.113072 100.75) (xy 132.100812 100.625518) (xy 132.064502 100.50582) (xy 132.005537 100.395506) (xy 131.926185 100.298815) - (xy 131.829494 100.219463) (xy 131.71918 100.160498) (xy 131.599482 100.124188) (xy 131.475 100.111928) (xy 131.463832 100.111928) - (xy 131.902826 99.818601) (xy 132.318601 99.402826) (xy 132.645273 98.913928) (xy 132.870288 98.370692) (xy 132.985 97.793997) - (xy 132.985 97.206003) (xy 132.870288 96.629308) (xy 132.645273 96.086072) (xy 132.318601 95.597174) (xy 131.902826 95.181399) - (xy 131.413928 94.854727) (xy 130.870692 94.629712) (xy 130.293997 94.515) (xy 129.706003 94.515) (xy 129.629325 94.530252) - (xy 129.666579 94.492998) (xy 129.956524 94.492998) + (xy 134.127805 99.373494) (xy 134.178412 99.540317) (xy 134.26059 99.694063) (xy 134.371184 99.828821) (xy 134.505942 99.939415) + (xy 134.659688 100.021593) (xy 134.826511 100.072199) (xy 135 100.089286) (xy 135.08523 100.080892) (xy 135.12373 100.127804) + (xy 135.16001 100.172011) (xy 135.189008 100.195809) (xy 135.479196 100.485997) (xy 135.502999 100.515001) (xy 135.618724 100.609974) + (xy 135.667965 100.636294) (xy 135.674188 100.699482) (xy 135.710498 100.81918) (xy 135.769463 100.929494) (xy 135.848815 101.026185) + (xy 135.910165 101.076533) (xy 134.378292 102.608407) (xy 131.777354 102.608407) (xy 131.829494 102.580537) (xy 131.926185 102.501185) + (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) (xy 132.113072 100.75) + (xy 132.100812 100.625518) (xy 132.064502 100.50582) (xy 132.005537 100.395506) (xy 131.926185 100.298815) (xy 131.829494 100.219463) + (xy 131.71918 100.160498) (xy 131.599482 100.124188) (xy 131.475 100.111928) (xy 131.463832 100.111928) (xy 131.902826 99.818601) + (xy 132.318601 99.402826) (xy 132.645273 98.913928) (xy 132.870288 98.370692) (xy 132.985 97.793997) (xy 132.985 97.206003) + (xy 132.870288 96.629308) (xy 132.645273 96.086072) (xy 132.318601 95.597174) (xy 131.902826 95.181399) (xy 131.413928 94.854727) + (xy 130.870692 94.629712) (xy 130.293997 94.515) (xy 129.706003 94.515) (xy 129.629325 94.530252) (xy 129.666579 94.492998) + (xy 129.956524 94.492998) ) ) (filled_polygon @@ -13050,36 +13048,6 @@ (xy 189.099482 85.724188) (xy 188.975 85.711928) (xy 188.025 85.711928) (xy 188.01 85.713405) (xy 188.01 75.21679) ) ) - (filled_polygon - (pts - (xy 181.64 73.502843) (xy 181.597089 73.60644) (xy 181.565 73.76776) (xy 181.565 73.93224) (xy 181.597089 74.09356) - (xy 181.660033 74.245521) (xy 181.751413 74.382281) (xy 181.867719 74.498587) (xy 182.004479 74.589967) (xy 182.108077 74.632879) - (xy 182.490001 75.014803) (xy 182.49 81.456867) (xy 182.49 81.456868) (xy 182.490001 83.362668) (xy 182.486324 83.4) - (xy 182.490001 83.437333) (xy 182.500998 83.548986) (xy 182.505641 83.564293) (xy 182.544454 83.692246) (xy 182.615026 83.824276) - (xy 182.684355 83.908753) (xy 182.71 83.940001) (xy 182.738998 83.963799) (xy 182.790199 84.015) (xy 182.523891 84.015) - (xy 182.217673 84.075911) (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) - (xy 181.153368 84.446525) (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) - (xy 180.615 85.74626) (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) - (xy 180.181817 86.383186) (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) - (xy 179.685576 83.888412) (xy 179.311588 83.514424) (xy 178.871825 83.220583) (xy 178.725564 83.16) (xy 179.315123 83.16) - (xy 179.35 83.163435) (xy 179.384877 83.16) (xy 179.396219 83.158883) (xy 179.489184 83.149727) (xy 179.62302 83.109128) - (xy 179.746363 83.0432) (xy 179.854475 82.954475) (xy 179.9432 82.846363) (xy 180.009128 82.72302) (xy 180.049727 82.589184) - (xy 180.06 82.484877) (xy 180.06 82.484876) (xy 180.063435 82.45) (xy 180.06 82.415123) (xy 180.06 82.11) - (xy 180.127002 82.11) (xy 180.127002 81.951252) (xy 180.28575 82.11) (xy 180.8 82.113072) (xy 180.924482 82.100812) - (xy 181.04418 82.064502) (xy 181.154494 82.005537) (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) - (xy 181.425812 81.599482) (xy 181.438072 81.475) (xy 181.435 81.26075) (xy 181.276252 81.102002) (xy 181.354245 81.102002) - (xy 181.35644 81.102911) (xy 181.51776 81.135) (xy 181.68224 81.135) (xy 181.84356 81.102911) (xy 181.995521 81.039967) - (xy 182.132281 80.948587) (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) - (xy 182.435 80.21776) (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) - (xy 181.995521 79.560033) (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.631802 79.465) (xy 181.438072 79.27127) - (xy 181.438072 78.725) (xy 181.425812 78.600518) (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) - (xy 181.154494 78.194463) (xy 181.04418 78.135498) (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.76 78.086928) - (xy 180.76 77.287322) (xy 180.763676 77.249999) (xy 180.76 77.212676) (xy 180.76 77.212667) (xy 180.749003 77.101014) - (xy 180.705546 76.957753) (xy 180.634974 76.825724) (xy 180.540001 76.709999) (xy 180.511003 76.686201) (xy 179.074999 75.250198) - (xy 179.074999 73.436132) (xy 179.128698 73.472012) (xy 179.517244 73.632953) (xy 179.929721 73.715) (xy 180.350279 73.715) - (xy 180.762756 73.632953) (xy 181.151302 73.472012) (xy 181.500983 73.238363) (xy 181.640001 73.099345) - ) - ) (filled_polygon (pts (xy 143.54 73.552843) (xy 143.497089 73.65644) (xy 143.465 73.81776) (xy 143.465 73.98224) (xy 143.497089 74.14356) @@ -13111,6 +13079,36 @@ (xy 143.540001 73.199345) ) ) + (filled_polygon + (pts + (xy 181.64 73.502843) (xy 181.597089 73.60644) (xy 181.565 73.76776) (xy 181.565 73.93224) (xy 181.597089 74.09356) + (xy 181.660033 74.245521) (xy 181.751413 74.382281) (xy 181.867719 74.498587) (xy 182.004479 74.589967) (xy 182.108077 74.632879) + (xy 182.490001 75.014803) (xy 182.49 81.456867) (xy 182.49 81.456868) (xy 182.490001 83.362668) (xy 182.486324 83.4) + (xy 182.490001 83.437333) (xy 182.500998 83.548986) (xy 182.505641 83.564293) (xy 182.544454 83.692246) (xy 182.615026 83.824276) + (xy 182.684355 83.908753) (xy 182.71 83.940001) (xy 182.738998 83.963799) (xy 182.790199 84.015) (xy 182.523891 84.015) + (xy 182.217673 84.075911) (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) + (xy 181.153368 84.446525) (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) + (xy 180.615 85.74626) (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) + (xy 180.181817 86.383186) (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) + (xy 179.685576 83.888412) (xy 179.311588 83.514424) (xy 178.871825 83.220583) (xy 178.725564 83.16) (xy 179.315123 83.16) + (xy 179.35 83.163435) (xy 179.384877 83.16) (xy 179.396219 83.158883) (xy 179.489184 83.149727) (xy 179.62302 83.109128) + (xy 179.746363 83.0432) (xy 179.854475 82.954475) (xy 179.9432 82.846363) (xy 180.009128 82.72302) (xy 180.049727 82.589184) + (xy 180.06 82.484877) (xy 180.06 82.484876) (xy 180.063435 82.45) (xy 180.06 82.415123) (xy 180.06 82.11) + (xy 180.127002 82.11) (xy 180.127002 81.951252) (xy 180.28575 82.11) (xy 180.8 82.113072) (xy 180.924482 82.100812) + (xy 181.04418 82.064502) (xy 181.154494 82.005537) (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) + (xy 181.425812 81.599482) (xy 181.438072 81.475) (xy 181.435 81.26075) (xy 181.276252 81.102002) (xy 181.354245 81.102002) + (xy 181.35644 81.102911) (xy 181.51776 81.135) (xy 181.68224 81.135) (xy 181.84356 81.102911) (xy 181.995521 81.039967) + (xy 182.132281 80.948587) (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) + (xy 182.435 80.21776) (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) + (xy 181.995521 79.560033) (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.631802 79.465) (xy 181.438072 79.27127) + (xy 181.438072 78.725) (xy 181.425812 78.600518) (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) + (xy 181.154494 78.194463) (xy 181.04418 78.135498) (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.76 78.086928) + (xy 180.76 77.287322) (xy 180.763676 77.249999) (xy 180.76 77.212676) (xy 180.76 77.212667) (xy 180.749003 77.101014) + (xy 180.705546 76.957753) (xy 180.634974 76.825724) (xy 180.540001 76.709999) (xy 180.511003 76.686201) (xy 179.074999 75.250198) + (xy 179.074999 73.436132) (xy 179.128698 73.472012) (xy 179.517244 73.632953) (xy 179.929721 73.715) (xy 180.350279 73.715) + (xy 180.762756 73.632953) (xy 181.151302 73.472012) (xy 181.500983 73.238363) (xy 181.640001 73.099345) + ) + ) (filled_polygon (pts (xy 187.149188 65.774482) (xy 187.185498 65.89418) (xy 187.244463 66.004494) (xy 187.323815 66.101185) (xy 187.420506 66.180537) @@ -13787,7 +13785,7 @@ (xy 215.337562 122.609422) (xy 214.544604 120.543696) (xy 187.343182 130.985343) (xy 188.11806 133.003968) (xy 187.30358 133.315) (xy 138.158838 133.315) (xy 138.096265 133.314123) (xy 138.058284 133.321126) (xy 138.019845 133.324912) (xy 137.959927 133.343088) (xy 93.864605 146.047335) (xy 93.520432 145.984758) (xy 93.243912 145.892584) (xy 93.08499 145.756366) (xy 82.933274 128.127044) - (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583074 116.011918) + (xy 82.826687 127.771756) (xy 82.785 127.271515) (xy 82.785 126.967828) (xy 82.851575 126.634954) (xy 88.583077 116.011913) (xy 88.59798 115.990873) (xy 88.615021 115.952706) (xy 88.618829 115.945648) (xy 88.62876 115.921935) (xy 88.639207 115.898536) (xy 88.641735 115.890952) (xy 88.657891 115.852374) (xy 88.663024 115.827087) (xy 88.84031 115.29523) (xy 88.855164 115.261034) (xy 88.868713 115.198522) (xy 88.882908 115.13609) (xy 88.883923 115.098817) (xy 88.948633 114.539922) (xy 88.950347 114.53427) @@ -14002,16 +14000,16 @@ (xy 111.010033 112.645521) (xy 111.101413 112.782281) (xy 111.217719 112.898587) (xy 111.354479 112.989967) (xy 111.50644 113.052911) (xy 111.66776 113.085) (xy 111.83224 113.085) (xy 111.99356 113.052911) (xy 112.04 113.033675) (xy 112.04 114.212679) (xy 112.036324 114.250002) (xy 112.04 114.287324) (xy 112.04 114.287334) (xy 112.050997 114.398987) (xy 112.087547 114.519479) - (xy 112.094454 114.542248) (xy 112.165026 114.674278) (xy 112.194342 114.709999) (xy 112.259999 114.790003) (xy 112.289002 114.813805) - (xy 112.961204 115.486009) (xy 112.984998 115.515002) (xy 113.013991 115.538796) (xy 113.013995 115.5388) (xy 113.075059 115.588913) + (xy 112.094454 114.542248) (xy 112.165026 114.674278) (xy 112.201854 114.719153) (xy 112.259999 114.790003) (xy 112.289002 114.813805) + (xy 112.961204 115.486009) (xy 112.984998 115.515002) (xy 113.013991 115.538796) (xy 113.013995 115.5388) (xy 113.075723 115.589458) (xy 113.100723 115.609975) (xy 113.232752 115.680547) (xy 113.376013 115.724004) (xy 113.487666 115.735001) (xy 113.487675 115.735001) (xy 113.524998 115.738677) (xy 113.562321 115.735001) (xy 126.487677 115.735001) (xy 126.524999 115.738677) (xy 126.562321 115.735001) (xy 126.562332 115.735001) (xy 126.673985 115.724004) (xy 126.817246 115.680547) (xy 126.949275 115.609975) (xy 127.065 115.515002) - (xy 127.088803 115.485999) (xy 128.011003 114.563799) (xy 128.040001 114.540001) (xy 128.130241 114.430043) (xy 129.356728 115.656531) - (xy 129.357689 115.66136) (xy 129.390926 115.741602) (xy 111.938924 115.741602) (xy 111.901601 115.737926) (xy 111.864278 115.741602) + (xy 127.088803 115.485999) (xy 128.011003 114.563799) (xy 128.040001 114.540001) (xy 128.073101 114.499669) (xy 129.036 115.462569) + (xy 129.036 115.715076) (xy 129.038613 115.741602) (xy 111.938924 115.741602) (xy 111.901601 115.737926) (xy 111.864278 115.741602) (xy 111.864269 115.741602) (xy 111.752616 115.752599) (xy 111.609355 115.796056) (xy 111.477326 115.866628) (xy 111.361601 115.961601) (xy 111.337803 115.990599) (xy 109.088403 118.24) (xy 108.037322 118.24) (xy 107.999999 118.236324) (xy 107.962676 118.24) - (xy 107.962667 118.24) (xy 107.851014 118.250997) (xy 107.709118 118.29404) (xy 107.707753 118.294454) (xy 107.575723 118.365026) + (xy 107.962667 118.24) (xy 107.851014 118.250997) (xy 107.722436 118.29) (xy 107.707753 118.294454) (xy 107.575723 118.365026) (xy 107.499176 118.427847) (xy 107.459999 118.459999) (xy 107.436201 118.488997) (xy 105.740026 120.185172) (xy 105.870288 119.870692) (xy 105.985 119.293997) (xy 105.985 118.706003) (xy 105.870288 118.129308) (xy 105.645273 117.586072) (xy 105.318601 117.097174) (xy 104.902826 116.681399) (xy 104.413928 116.354727) (xy 103.870692 116.129712) (xy 103.293997 116.015) (xy 102.706003 116.015) @@ -14357,20 +14355,19 @@ ) (filled_polygon (pts - (xy 103.6686 128.39664) (xy 103.700689 128.55796) (xy 103.763633 128.709921) (xy 103.855013 128.846681) (xy 103.971319 128.962987) - (xy 104.108079 129.054367) (xy 104.26004 129.117311) (xy 104.42136 129.1494) (xy 104.58584 129.1494) (xy 104.74716 129.117311) - (xy 104.850757 129.0744) (xy 108.850798 129.0744) (xy 104.600292 133.324907) (xy 104.600253 133.324933) (xy 104.568436 133.35675) - (xy 104.539506 133.380492) (xy 104.515763 133.409423) (xy 104.483947 133.441239) (xy 104.45895 133.47865) (xy 104.455361 133.483023) - (xy 103.698385 134.24) (xy 103.514803 134.24) (xy 103.261276 133.986474) (xy 103.320649 133.890993) (xy 103.329993 133.866166) - (xy 103.356167 133.870487) (xy 103.481184 133.866395) (xy 103.603001 133.837991) (xy 103.716935 133.786368) (xy 103.900945 133.676582) - (xy 103.959052 133.459726) (xy 103.384427 132.464446) (xy 103.367106 132.474446) (xy 103.342981 132.432661) (xy 103.597593 132.285661) - (xy 103.621718 132.327446) (xy 103.604397 132.337446) (xy 104.179022 133.332726) (xy 104.395879 133.390832) (xy 104.582961 133.286368) - (xy 104.684635 133.213509) (xy 104.770142 133.122215) (xy 104.836194 133.015993) (xy 104.880255 132.898926) (xy 104.90063 132.775514) - (xy 104.896538 132.650496) (xy 104.868135 132.52868) (xy 104.816511 132.414745) (xy 104.556726 131.970928) (xy 104.339872 131.912822) - (xy 104.477352 131.833448) (xy 104.453226 131.791661) (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) - (xy 104.651604 131.677128) (xy 104.7368 131.616078) (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) - (xy 104.978308 131.126349) (xy 104.973731 130.986567) (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.898716 130.754892) - (xy 104.884253 130.722971) (xy 104.863839 130.694483) (xy 103.527189 128.379338) (xy 103.6686 128.379338) + (xy 103.874783 128.943217) (xy 104.009541 129.053811) (xy 104.163287 129.135989) (xy 104.33011 129.186595) (xy 104.460123 129.1994) + (xy 108.725798 129.1994) (xy 104.600292 133.324907) (xy 104.600253 133.324933) (xy 104.568436 133.35675) (xy 104.539506 133.380492) + (xy 104.515763 133.409423) (xy 104.483947 133.441239) (xy 104.45895 133.47865) (xy 104.455361 133.483023) (xy 103.698385 134.24) + (xy 103.514803 134.24) (xy 103.261276 133.986474) (xy 103.320649 133.890993) (xy 103.329993 133.866166) (xy 103.356167 133.870487) + (xy 103.481184 133.866395) (xy 103.603001 133.837991) (xy 103.716935 133.786368) (xy 103.900945 133.676582) (xy 103.959052 133.459726) + (xy 103.384427 132.464446) (xy 103.367106 132.474446) (xy 103.342981 132.432661) (xy 103.597593 132.285661) (xy 103.621718 132.327446) + (xy 103.604397 132.337446) (xy 104.179022 133.332726) (xy 104.395879 133.390832) (xy 104.582961 133.286368) (xy 104.684635 133.213509) + (xy 104.770142 133.122215) (xy 104.836194 133.015993) (xy 104.880255 132.898926) (xy 104.90063 132.775514) (xy 104.896538 132.650496) + (xy 104.868135 132.52868) (xy 104.816511 132.414745) (xy 104.556726 131.970928) (xy 104.339872 131.912822) (xy 104.477352 131.833448) + (xy 104.453226 131.791661) (xy 104.591205 131.711999) (xy 104.623117 131.69754) (xy 104.651595 131.677133) (xy 104.651604 131.677128) + (xy 104.7368 131.616078) (xy 104.832406 131.514) (xy 104.90626 131.395233) (xy 104.955525 131.264339) (xy 104.978308 131.126349) + (xy 104.973731 130.986567) (xy 104.972624 130.981817) (xy 104.941973 130.850361) (xy 104.898716 130.754892) (xy 104.884253 130.722971) + (xy 104.863839 130.694483) (xy 103.800454 128.852648) ) ) (filled_polygon @@ -14545,160 +14542,166 @@ (xy 187.386928 107.875) (xy 187.386928 109.175) (xy 187.399188 109.299482) (xy 187.435498 109.41918) (xy 187.494463 109.529494) (xy 187.573815 109.626185) (xy 187.670506 109.705537) (xy 187.771501 109.759521) (xy 187.7715 113.344177) (xy 187.767824 113.3815) (xy 187.7715 113.418822) (xy 187.7715 113.418832) (xy 187.782497 113.530485) (xy 187.813746 113.633501) (xy 187.825954 113.673746) - (xy 187.896526 113.805776) (xy 187.92327 113.838363) (xy 187.991499 113.921501) (xy 188.020503 113.945304) (xy 188.217121 114.141922) + (xy 187.896526 113.805776) (xy 187.929383 113.845812) (xy 187.991499 113.921501) (xy 188.020503 113.945304) (xy 188.217121 114.141922) (xy 188.240001 114.197159) (xy 188.24 115.212677) (xy 188.236324 115.25) (xy 188.24 115.287322) (xy 188.24 115.287332) (xy 188.250997 115.398985) (xy 188.290959 115.530725) (xy 188.294454 115.542246) (xy 188.365026 115.674276) (xy 188.397475 115.713815) - (xy 188.459999 115.790001) (xy 188.489003 115.813804) (xy 190.440198 117.765) (xy 189.906523 117.765) (xy 189.77651 117.777805) - (xy 189.609687 117.828411) (xy 189.455941 117.910589) (xy 189.321183 118.021183) (xy 189.210589 118.155941) (xy 189.128411 118.309687) - (xy 189.077805 118.47651) (xy 189.060718 118.65) (xy 189.077805 118.82349) (xy 189.117654 118.954853) (xy 189.095304 118.932503) - (xy 189.071501 118.903499) (xy 188.955776 118.808526) (xy 188.855995 118.755191) (xy 188.839502 118.70082) (xy 188.780537 118.590506) - (xy 188.701185 118.493815) (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) (xy 188.25 118.306928) - (xy 186.25 118.306928) (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) (xy 185.798815 118.493815) - (xy 185.719463 118.590506) (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) (xy 185.611928 119.945) - (xy 185.624188 120.069482) (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) (xy 185.719463 120.340506) - (xy 185.660498 120.45082) (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.260001) (xy 184.488072 121.260001) - (xy 184.488072 120.695) (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) (xy 184.363708 120.32) - (xy 184.380537 120.299494) (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) (xy 184.485 119.73075) - (xy 184.32625 119.572) (xy 182.977 119.572) (xy 182.977 119.592) (xy 182.723 119.592) (xy 182.723 119.572) - (xy 182.703 119.572) (xy 182.703 119.318) (xy 182.723 119.318) (xy 182.723 119.298) (xy 182.977 119.298) - (xy 182.977 119.318) (xy 184.32625 119.318) (xy 184.485 119.15925) (xy 184.488072 118.945) (xy 184.475812 118.820518) - (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) (xy 184.379711 118.35376) - (xy 184.4118 118.19244) (xy 184.4118 118.02796) (xy 184.379711 117.86664) (xy 184.316767 117.714679) (xy 184.225387 117.577919) - (xy 184.109081 117.461613) (xy 183.972321 117.370233) (xy 183.82036 117.307289) (xy 183.65904 117.2752) (xy 183.49456 117.2752) - (xy 183.33324 117.307289) (xy 183.181279 117.370233) (xy 183.044519 117.461613) (xy 183.003532 117.5026) (xy 182.120557 117.5026) - (xy 182.01696 117.459689) (xy 181.85564 117.4276) (xy 181.69116 117.4276) (xy 181.52984 117.459689) (xy 181.377879 117.522633) - (xy 181.299353 117.575103) (xy 181.27625 117.552) (xy 180.127 117.552) (xy 180.127 117.572) (xy 180.0588 117.572) - (xy 180.0588 117.278) (xy 180.127 117.278) (xy 180.127 117.298) (xy 181.27625 117.298) (xy 181.435 117.13925) - (xy 181.438072 116.925) (xy 181.425812 116.800518) (xy 181.389502 116.68082) (xy 181.330537 116.570506) (xy 181.251185 116.473815) - (xy 181.154494 116.394463) (xy 181.04418 116.335498) (xy 180.924482 116.299188) (xy 180.8 116.286928) (xy 180.28575 116.29) - (xy 180.127002 116.448748) (xy 180.127002 116.29) (xy 180.0588 116.29) (xy 180.0588 116.070077) (xy 180.062235 116.0352) - (xy 180.048527 115.896016) (xy 180.007928 115.76218) (xy 179.942 115.638837) (xy 179.853275 115.530725) (xy 179.745163 115.442) - (xy 179.62182 115.376072) (xy 179.487984 115.335473) (xy 179.383677 115.3252) (xy 179.3488 115.321765) (xy 179.313923 115.3252) - (xy 175.883677 115.3252) (xy 175.863196 115.323183) (xy 175.848587 115.301319) (xy 175.732281 115.185013) (xy 175.595521 115.093633) - (xy 175.44356 115.030689) (xy 175.28224 114.9986) (xy 175.11776 114.9986) (xy 174.95644 115.030689) (xy 174.804479 115.093633) - (xy 174.667719 115.185013) (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) (xy 174.365 115.75136) - (xy 174.365 115.91584) (xy 174.397089 116.07716) (xy 174.44 116.180757) (xy 174.44 116.286928) (xy 174.4 116.286928) - (xy 174.275518 116.299188) (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) (xy 173.869463 116.570506) - (xy 173.810498 116.68082) (xy 173.774188 116.800518) (xy 173.761928 116.925) (xy 173.761928 117.453) (xy 173.74096 117.453) - (xy 173.6168 117.477697) (xy 173.6168 117.31676) (xy 173.584711 117.15544) (xy 173.521767 117.003479) (xy 173.430387 116.866719) - (xy 173.314081 116.750413) (xy 173.177321 116.659033) (xy 173.02536 116.596089) (xy 172.86404 116.564) (xy 172.729 116.564) - (xy 172.729 115.612557) (xy 172.771911 115.50896) (xy 172.804 115.34764) (xy 172.804 115.18316) (xy 172.771911 115.02184) - (xy 172.708967 114.869879) (xy 172.617587 114.733119) (xy 172.501281 114.616813) (xy 172.364521 114.525433) (xy 172.21256 114.462489) - (xy 172.05124 114.4304) (xy 171.88676 114.4304) (xy 171.72544 114.462489) (xy 171.573479 114.525433) (xy 171.436719 114.616813) - (xy 171.320413 114.733119) (xy 171.229033 114.869879) (xy 171.166089 115.02184) (xy 171.134 115.18316) (xy 171.134 115.34764) - (xy 171.166089 115.50896) (xy 171.209 115.612557) (xy 171.209001 119.921198) (xy 167.388072 123.742128) (xy 167.388072 122.87) - (xy 167.375812 122.745518) (xy 167.339502 122.62582) (xy 167.280537 122.515506) (xy 167.201185 122.418815) (xy 167.104494 122.339463) - (xy 166.99418 122.280498) (xy 166.874482 122.244188) (xy 166.75 122.231928) (xy 164.956887 122.231928) (xy 165.084609 122.040779) - (xy 165.204089 121.752327) (xy 165.265 121.446109) (xy 165.265 121.133891) (xy 165.204089 120.827673) (xy 165.084609 120.539221) - (xy 164.91115 120.279621) (xy 164.690379 120.05885) (xy 164.430779 119.885391) (xy 164.142327 119.765911) (xy 163.836109 119.705) - (xy 163.523891 119.705) (xy 163.217673 119.765911) (xy 163.123303 119.805) (xy 162.95374 119.805) (xy 162.666842 119.862068) - (xy 162.396589 119.97401) (xy 162.153368 120.136525) (xy 161.946525 120.343368) (xy 161.78401 120.586589) (xy 161.672068 120.856842) - (xy 161.615 121.14374) (xy 161.615 121.43626) (xy 161.672068 121.723158) (xy 161.707988 121.809876) (xy 161.398698 121.937988) - (xy 161.176252 122.086622) (xy 161.181817 122.073186) (xy 161.285 121.554449) (xy 161.285 121.025551) (xy 161.181817 120.506814) - (xy 160.979417 120.018175) (xy 160.750114 119.674999) (xy 160.911927 119.674999) (xy 160.949249 119.678675) (xy 160.986571 119.674999) - (xy 160.986582 119.674999) (xy 161.098235 119.664002) (xy 161.241496 119.620545) (xy 161.373525 119.549973) (xy 161.48925 119.455) - (xy 161.513053 119.425996) (xy 166.460999 114.478051) (xy 166.489997 114.454253) (xy 166.58497 114.338528) (xy 166.655542 114.206499) - (xy 166.698999 114.063237) (xy 166.706509 113.986984) (xy 166.752907 113.87497) (xy 166.754612 113.8664) (xy 183.798742 113.8664) - (xy 183.836064 113.870076) (xy 183.873386 113.8664) (xy 183.873397 113.8664) (xy 183.98505 113.855403) (xy 184.128311 113.811946) - (xy 184.26034 113.741374) (xy 184.376065 113.646401) (xy 184.399867 113.617398) (xy 184.925455 113.09181) (xy 185.029053 113.048899) - (xy 185.165813 112.957519) (xy 185.282119 112.841213) (xy 185.373499 112.704453) (xy 185.436443 112.552492) (xy 185.468532 112.391172) - (xy 185.468532 112.226692) (xy 185.436443 112.065372) (xy 185.373499 111.913411) (xy 185.282119 111.776651) (xy 185.165813 111.660345) - (xy 185.029053 111.568965) (xy 184.877092 111.506021) (xy 184.715772 111.473932) (xy 184.551292 111.473932) (xy 184.389972 111.506021) - (xy 184.238011 111.568965) (xy 184.101251 111.660345) (xy 183.984945 111.776651) (xy 183.893565 111.913411) (xy 183.850654 112.017009) - (xy 183.521263 112.3464) (xy 182.378401 112.3464) (xy 185.111003 109.613799) (xy 185.140001 109.590001) (xy 185.181036 109.54) - (xy 185.234974 109.474277) (xy 185.305546 109.342247) (xy 185.320315 109.29356) (xy 185.349003 109.198986) (xy 185.36 109.087333) - (xy 185.36 109.087324) (xy 185.363676 109.050001) (xy 185.36 109.012678) (xy 185.36 108.918072) (xy 185.75 108.918072) - (xy 185.874482 108.905812) (xy 185.99418 108.869502) (xy 186.104494 108.810537) (xy 186.201185 108.731185) (xy 186.280537 108.634494) - (xy 186.339502 108.52418) (xy 186.375812 108.404482) (xy 186.388072 108.28) (xy 186.388072 106.28) (xy 186.375812 106.155518) - (xy 186.339502 106.03582) (xy 186.280537 105.925506) (xy 186.201185 105.828815) (xy 186.104494 105.749463) (xy 185.99418 105.690498) - (xy 185.874482 105.654188) (xy 185.75 105.641928) (xy 183.956887 105.641928) (xy 184.084609 105.450779) (xy 184.204089 105.162327) - (xy 184.265 104.856109) (xy 184.265 104.543891) (xy 184.22146 104.325) (xy 187.386928 104.325) (xy 187.386928 105.625) - (xy 187.399188 105.749482) (xy 187.435498 105.86918) (xy 187.494463 105.979494) (xy 187.573815 106.076185) (xy 187.670506 106.155537) - (xy 187.78082 106.214502) (xy 187.900518 106.250812) (xy 188.025 106.263072) (xy 188.650908 106.263072) (xy 188.738913 106.394781) - (xy 188.855219 106.511087) (xy 188.991979 106.602467) (xy 189.14394 106.665411) (xy 189.30526 106.6975) (xy 189.46974 106.6975) - (xy 189.63106 106.665411) (xy 189.783021 106.602467) (xy 189.919781 106.511087) (xy 190.036087 106.394781) (xy 190.127467 106.258021) - (xy 190.190411 106.10606) (xy 190.2225 105.94474) (xy 190.2225 105.78026) (xy 190.190411 105.61894) (xy 190.127467 105.466979) - (xy 190.036087 105.330219) (xy 189.919781 105.213913) (xy 189.783021 105.122533) (xy 189.679423 105.079622) (xy 189.613072 105.01327) - (xy 189.613072 104.325) (xy 189.600812 104.200518) (xy 189.564502 104.08082) (xy 189.505537 103.970506) (xy 189.426185 103.873815) - (xy 189.329494 103.794463) (xy 189.21918 103.735498) (xy 189.099482 103.699188) (xy 188.975 103.686928) (xy 188.025 103.686928) - (xy 187.900518 103.699188) (xy 187.78082 103.735498) (xy 187.670506 103.794463) (xy 187.573815 103.873815) (xy 187.494463 103.970506) - (xy 187.435498 104.08082) (xy 187.399188 104.200518) (xy 187.386928 104.325) (xy 184.22146 104.325) (xy 184.204089 104.237673) - (xy 184.084609 103.949221) (xy 183.91115 103.689621) (xy 183.690379 103.46885) (xy 183.430779 103.295391) (xy 183.142327 103.175911) - (xy 182.836109 103.115) (xy 182.523891 103.115) (xy 182.217673 103.175911) (xy 182.123303 103.215) (xy 181.95374 103.215) - (xy 181.666842 103.272068) (xy 181.396589 103.38401) (xy 181.153368 103.546525) (xy 180.946525 103.753368) (xy 180.78401 103.996589) - (xy 180.672068 104.266842) (xy 180.615 104.55374) (xy 180.615 104.84626) (xy 180.672068 105.133158) (xy 180.707988 105.219876) - (xy 180.398698 105.347988) (xy 180.176252 105.496622) (xy 180.181817 105.483186) (xy 180.285 104.964449) (xy 180.285 104.435551) - (xy 180.181817 103.916814) (xy 179.979417 103.428175) (xy 179.685576 102.988412) (xy 179.311588 102.614424) (xy 178.871825 102.320583) - (xy 178.725564 102.26) (xy 179.315123 102.26) (xy 179.35 102.263435) (xy 179.384877 102.26) (xy 179.489184 102.249727) - (xy 179.62302 102.209128) (xy 179.746363 102.1432) (xy 179.854475 102.054475) (xy 179.9432 101.946363) (xy 180.009128 101.82302) - (xy 180.049727 101.689184) (xy 180.063435 101.55) (xy 180.06 101.515123) (xy 180.06 101.213072) (xy 180.8 101.213072) - (xy 180.924482 101.200812) (xy 181.04418 101.164502) (xy 181.154494 101.105537) (xy 181.251185 101.026185) (xy 181.330537 100.929494) - (xy 181.389502 100.81918) (xy 181.425812 100.699482) (xy 181.438072 100.575) (xy 181.438072 99.92573) (xy 181.761004 99.602798) - (xy 181.790001 99.579001) (xy 181.884974 99.463276) (xy 181.913356 99.410177) (xy 181.989967 99.295521) (xy 182.052911 99.14356) - (xy 182.085 98.98224) (xy 182.085 98.81776) (xy 182.052911 98.65644) (xy 181.989967 98.504479) (xy 181.898587 98.367719) - (xy 181.782281 98.251413) (xy 181.645521 98.160033) (xy 181.49356 98.097089) (xy 181.396473 98.077777) (xy 181.435 98.03925) - (xy 181.438072 97.825) (xy 181.425812 97.700518) (xy 181.389502 97.58082) (xy 181.330537 97.470506) (xy 181.251185 97.373815) - (xy 181.154494 97.294463) (xy 181.04418 97.235498) (xy 180.924482 97.199188) (xy 180.8 97.186928) (xy 180.28575 97.19) - (xy 180.127002 97.348748) (xy 180.127002 97.19) (xy 180.06 97.19) (xy 180.06 97.084877) (xy 180.063435 97.05) - (xy 180.049727 96.910816) (xy 180.009128 96.77698) (xy 179.9432 96.653637) (xy 179.854475 96.545525) (xy 179.746363 96.4568) - (xy 179.62302 96.390872) (xy 179.489184 96.350273) (xy 179.384877 96.34) (xy 179.35 96.336565) (xy 179.315123 96.34) - (xy 175.884877 96.34) (xy 175.85 96.336565) (xy 175.815123 96.34) (xy 175.710816 96.350273) (xy 175.57698 96.390872) - (xy 175.453637 96.4568) (xy 175.345525 96.545525) (xy 175.2568 96.653637) (xy 175.190872 96.77698) (xy 175.150273 96.910816) - (xy 175.136565 97.05) (xy 175.140001 97.084887) (xy 175.140001 97.186928) (xy 174.4 97.186928) (xy 174.275518 97.199188) - (xy 174.15582 97.235498) (xy 174.045506 97.294463) (xy 173.948815 97.373815) (xy 173.869463 97.470506) (xy 173.810498 97.58082) - (xy 173.798882 97.619111) (xy 173.797753 97.619454) (xy 173.665723 97.690026) (xy 173.59386 97.749003) (xy 173.549999 97.784999) - (xy 173.5262 97.813998) (xy 172.989002 98.351197) (xy 172.959999 98.374999) (xy 172.919797 98.423986) (xy 172.865026 98.490724) - (xy 172.814634 98.585) (xy 172.794454 98.622754) (xy 172.750997 98.766015) (xy 172.749669 98.779501) (xy 172.697089 98.90644) - (xy 172.665 99.06776) (xy 172.665 99.076799) (xy 172.659687 99.078411) (xy 172.505941 99.160589) (xy 172.371183 99.271183) - (xy 172.260589 99.405941) (xy 172.178411 99.559687) (xy 172.127805 99.72651) (xy 172.110718 99.9) (xy 172.127805 100.07349) - (xy 172.178411 100.240313) (xy 172.260589 100.394059) (xy 172.371183 100.528817) (xy 172.505941 100.639411) (xy 172.659687 100.721589) - (xy 172.82651 100.772195) (xy 172.956523 100.785) (xy 173.80013 100.785) (xy 173.810498 100.81918) (xy 173.869463 100.929494) - (xy 173.948815 101.026185) (xy 174.045506 101.105537) (xy 174.15582 101.164502) (xy 174.275518 101.200812) (xy 174.4 101.213072) - (xy 175.14 101.213072) (xy 175.14 101.515123) (xy 175.136565 101.55) (xy 175.150273 101.689184) (xy 175.190872 101.82302) - (xy 175.2568 101.946363) (xy 175.345525 102.054475) (xy 175.430471 102.124188) (xy 175.453637 102.1432) (xy 175.57698 102.209128) - (xy 175.710816 102.249727) (xy 175.85 102.263435) (xy 175.884877 102.26) (xy 176.474436 102.26) (xy 176.328175 102.320583) - (xy 175.888412 102.614424) (xy 175.514424 102.988412) (xy 175.220583 103.428175) (xy 175.018183 103.916814) (xy 174.915 104.435551) - (xy 174.915 104.964449) (xy 175.018183 105.483186) (xy 175.023749 105.496623) (xy 174.801302 105.347989) (xy 174.492012 105.219877) - (xy 174.527932 105.133158) (xy 174.585 104.84626) (xy 174.585 104.55374) (xy 174.527932 104.266842) (xy 174.41599 103.996589) - (xy 174.253475 103.753368) (xy 174.046632 103.546525) (xy 173.803411 103.38401) (xy 173.533158 103.272068) (xy 173.24626 103.215) - (xy 173.076697 103.215) (xy 172.982327 103.175911) (xy 172.676109 103.115) (xy 172.363891 103.115) (xy 172.057673 103.175911) - (xy 171.769221 103.295391) (xy 171.509621 103.46885) (xy 171.28885 103.689621) (xy 171.115391 103.949221) (xy 170.995911 104.237673) - (xy 170.935 104.543891) (xy 170.935 104.856109) (xy 170.995911 105.162327) (xy 171.115391 105.450779) (xy 171.28885 105.710379) - (xy 171.509621 105.93115) (xy 171.769221 106.104609) (xy 171.935016 106.173283) (xy 171.897988 106.228699) (xy 171.737047 106.617245) - (xy 171.655 107.029722) (xy 171.655 107.45028) (xy 171.737047 107.862757) (xy 171.869252 108.181928) (xy 170.75 108.181928) - (xy 170.625518 108.194188) (xy 170.50582 108.230498) (xy 170.395506 108.289463) (xy 170.336818 108.337627) (xy 170.295521 108.310033) - (xy 170.191923 108.267122) (xy 170.01 108.085199) (xy 170.01 105.142683) (xy 170.079494 105.105537) (xy 170.176185 105.026185) - (xy 170.255537 104.929494) (xy 170.314502 104.81918) (xy 170.350812 104.699482) (xy 170.363072 104.575) (xy 170.363072 103.275) - (xy 170.350812 103.150518) (xy 170.314502 103.03082) (xy 170.255537 102.920506) (xy 170.176185 102.823815) (xy 170.079494 102.744463) - (xy 169.96918 102.685498) (xy 169.849482 102.649188) (xy 169.725 102.636928) (xy 168.775 102.636928) (xy 168.650518 102.649188) - (xy 168.53082 102.685498) (xy 168.420506 102.744463) (xy 168.323815 102.823815) (xy 168.244463 102.920506) (xy 168.185498 103.03082) - (xy 168.149188 103.150518) (xy 168.136928 103.275) (xy 168.136928 104.575) (xy 168.149188 104.699482) (xy 168.185498 104.81918) - (xy 168.244463 104.929494) (xy 168.323815 105.026185) (xy 168.420506 105.105537) (xy 168.49 105.142683) (xy 168.490001 108.362668) - (xy 168.486324 108.4) (xy 168.490001 108.437333) (xy 168.500998 108.548986) (xy 168.50721 108.569463) (xy 168.544454 108.692246) - (xy 168.615026 108.824276) (xy 168.675829 108.898364) (xy 168.71 108.940001) (xy 168.738998 108.963799) (xy 169.117122 109.341923) - (xy 169.140001 109.397159) (xy 169.14 110.485673) (xy 169.136324 110.522996) (xy 169.14 110.560318) (xy 169.14 110.560328) - (xy 169.150997 110.671981) (xy 169.19119 110.804482) (xy 169.194454 110.815242) (xy 169.265026 110.947272) (xy 169.28823 110.975546) - (xy 169.359999 111.062997) (xy 169.389003 111.0868) (xy 170.648602 112.3464) (xy 168.483846 112.3464) (xy 168.543367 112.257321) - (xy 168.606311 112.10536) (xy 168.6384 111.94404) (xy 168.6384 111.77956) (xy 168.606311 111.61824) (xy 168.543367 111.466279) - (xy 168.451987 111.329519) (xy 168.335681 111.213213) (xy 168.198921 111.121833) (xy 168.04696 111.058889) (xy 167.88564 111.0268) - (xy 167.72116 111.0268) (xy 167.55984 111.058889) (xy 167.456243 111.1018) (xy 166.764397 111.1018) (xy 166.66855 111.062099) - (xy 166.50723 111.03001) (xy 166.34275 111.03001) (xy 166.18143 111.062099) (xy 166.029469 111.125043) (xy 165.892709 111.216423) - (xy 165.776403 111.332729) (xy 165.685023 111.469489) (xy 165.622079 111.62145) (xy 165.58999 111.78277) (xy 165.58999 111.94725) - (xy 165.622079 112.10857) (xy 165.685023 112.260531) (xy 165.742399 112.3464) (xy 163.836311 112.3464) (xy 163.798988 112.342724) - (xy 163.761666 112.3464) (xy 163.761655 112.3464) (xy 163.650002 112.357397) (xy 163.521391 112.39641) (xy 163.500209 112.39641) - (xy 163.371598 112.357397) (xy 163.259945 112.3464) (xy 163.259934 112.3464) (xy 163.222612 112.342724) (xy 163.18529 112.3464) - (xy 156.751823 112.3464) (xy 156.7145 112.342724) (xy 156.677177 112.3464) (xy 156.677168 112.3464) (xy 156.565515 112.357397) - (xy 156.422254 112.400854) (xy 156.290225 112.471426) (xy 156.1745 112.566399) (xy 156.150701 112.595398) (xy 155.688998 113.057102) - (xy 155.66 113.0809) (xy 155.636202 113.109898) (xy 155.636201 113.109899) (xy 155.565026 113.196625) (xy 155.494454 113.328655) - (xy 155.472514 113.400984) (xy 155.450998 113.471915) (xy 155.442078 113.562481) (xy 155.436324 113.620901) (xy 155.440001 113.658233) - (xy 155.440001 113.776928) (xy 155.4 113.776928) (xy 155.275518 113.789188) (xy 155.15582 113.825498) (xy 155.045506 113.884463) - (xy 154.948815 113.963815) (xy 154.869463 114.060506) (xy 154.810498 114.17082) (xy 154.777728 114.278848) (xy 154.775524 114.280026) - (xy 154.659799 114.374999) (xy 154.636 114.403998) (xy 154.287602 114.752397) (xy 154.258599 114.776199) (xy 154.217716 114.826016) - (xy 154.163626 114.891924) (xy 154.1298 114.955208) (xy 154.1298 114.83276) (xy 154.097711 114.67144) (xy 154.034767 114.519479) - (xy 153.943387 114.382719) (xy 153.827081 114.266413) (xy 153.690321 114.175033) (xy 153.53836 114.112089) (xy 153.37704 114.08) - (xy 153.21256 114.08) (xy 153.05124 114.112089) (xy 152.899279 114.175033) (xy 152.762519 114.266413) (xy 152.646213 114.382719) - (xy 152.554833 114.519479) (xy 152.491889 114.67144) (xy 152.4598 114.83276) (xy 152.4598 114.99724) (xy 152.491889 115.15856) - (xy 152.534801 115.262159) (xy 152.5348 116.30185) (xy 152.52778 116.298098) (xy 152.408082 116.261788) (xy 152.2836 116.249528) + (xy 188.459999 115.790001) (xy 188.489003 115.813804) (xy 190.440198 117.765) (xy 189.993477 117.765) (xy 189.95 117.760718) + (xy 189.906524 117.765) (xy 189.906523 117.765) (xy 189.77651 117.777805) (xy 189.609687 117.828411) (xy 189.455941 117.910589) + (xy 189.321183 118.021183) (xy 189.210589 118.155941) (xy 189.128411 118.309687) (xy 189.077805 118.47651) (xy 189.060718 118.65) + (xy 189.065001 118.693486) (xy 189.065001 118.898164) (xy 188.955776 118.808526) (xy 188.855995 118.755191) (xy 188.839502 118.70082) + (xy 188.780537 118.590506) (xy 188.701185 118.493815) (xy 188.604494 118.414463) (xy 188.49418 118.355498) (xy 188.374482 118.319188) + (xy 188.25 118.306928) (xy 186.25 118.306928) (xy 186.125518 118.319188) (xy 186.00582 118.355498) (xy 185.895506 118.414463) + (xy 185.798815 118.493815) (xy 185.719463 118.590506) (xy 185.660498 118.70082) (xy 185.624188 118.820518) (xy 185.611928 118.945) + (xy 185.611928 119.945) (xy 185.624188 120.069482) (xy 185.660498 120.18918) (xy 185.719463 120.299494) (xy 185.736292 120.32) + (xy 185.719463 120.340506) (xy 185.660498 120.45082) (xy 185.624188 120.570518) (xy 185.611928 120.695) (xy 185.611928 121.260001) + (xy 184.488072 121.260001) (xy 184.488072 120.695) (xy 184.475812 120.570518) (xy 184.439502 120.45082) (xy 184.380537 120.340506) + (xy 184.363708 120.32) (xy 184.380537 120.299494) (xy 184.439502 120.18918) (xy 184.475812 120.069482) (xy 184.488072 119.945) + (xy 184.485 119.73075) (xy 184.32625 119.572) (xy 182.977 119.572) (xy 182.977 119.592) (xy 182.723 119.592) + (xy 182.723 119.572) (xy 182.703 119.572) (xy 182.703 119.318) (xy 182.723 119.318) (xy 182.723 119.298) + (xy 182.977 119.298) (xy 182.977 119.318) (xy 184.32625 119.318) (xy 184.485 119.15925) (xy 184.488072 118.945) + (xy 184.475812 118.820518) (xy 184.439502 118.70082) (xy 184.380537 118.590506) (xy 184.314159 118.509624) (xy 184.316767 118.505721) + (xy 184.379711 118.35376) (xy 184.4118 118.19244) (xy 184.4118 118.02796) (xy 184.379711 117.86664) (xy 184.316767 117.714679) + (xy 184.225387 117.577919) (xy 184.109081 117.461613) (xy 183.972321 117.370233) (xy 183.82036 117.307289) (xy 183.65904 117.2752) + (xy 183.49456 117.2752) (xy 183.33324 117.307289) (xy 183.181279 117.370233) (xy 183.044519 117.461613) (xy 183.003532 117.5026) + (xy 182.120557 117.5026) (xy 182.01696 117.459689) (xy 181.85564 117.4276) (xy 181.69116 117.4276) (xy 181.52984 117.459689) + (xy 181.377879 117.522633) (xy 181.299353 117.575103) (xy 181.27625 117.552) (xy 180.127 117.552) (xy 180.127 117.572) + (xy 180.0588 117.572) (xy 180.0588 117.278) (xy 180.127 117.278) (xy 180.127 117.298) (xy 181.27625 117.298) + (xy 181.435 117.13925) (xy 181.438072 116.925) (xy 181.425812 116.800518) (xy 181.389502 116.68082) (xy 181.330537 116.570506) + (xy 181.251185 116.473815) (xy 181.154494 116.394463) (xy 181.04418 116.335498) (xy 180.924482 116.299188) (xy 180.8 116.286928) + (xy 180.28575 116.29) (xy 180.127002 116.448748) (xy 180.127002 116.29) (xy 180.0588 116.29) (xy 180.0588 116.070077) + (xy 180.062235 116.0352) (xy 180.048527 115.896016) (xy 180.007928 115.76218) (xy 179.942 115.638837) (xy 179.853275 115.530725) + (xy 179.745163 115.442) (xy 179.62182 115.376072) (xy 179.487984 115.335473) (xy 179.383677 115.3252) (xy 179.3488 115.321765) + (xy 179.313923 115.3252) (xy 175.883677 115.3252) (xy 175.863196 115.323183) (xy 175.848587 115.301319) (xy 175.732281 115.185013) + (xy 175.595521 115.093633) (xy 175.44356 115.030689) (xy 175.28224 114.9986) (xy 175.11776 114.9986) (xy 174.95644 115.030689) + (xy 174.804479 115.093633) (xy 174.667719 115.185013) (xy 174.551413 115.301319) (xy 174.460033 115.438079) (xy 174.397089 115.59004) + (xy 174.365 115.75136) (xy 174.365 115.91584) (xy 174.397089 116.07716) (xy 174.44 116.180757) (xy 174.44 116.286928) + (xy 174.4 116.286928) (xy 174.275518 116.299188) (xy 174.15582 116.335498) (xy 174.045506 116.394463) (xy 173.948815 116.473815) + (xy 173.869463 116.570506) (xy 173.810498 116.68082) (xy 173.774188 116.800518) (xy 173.761928 116.925) (xy 173.761928 117.453) + (xy 173.74096 117.453) (xy 173.6668 117.467752) (xy 173.6668 117.355523) (xy 173.653995 117.22551) (xy 173.603389 117.058687) + (xy 173.521211 116.904941) (xy 173.410617 116.770183) (xy 173.275859 116.659589) (xy 173.122113 116.577411) (xy 172.95529 116.526805) + (xy 172.7818 116.509718) (xy 172.729 116.514918) (xy 172.729 115.612557) (xy 172.771911 115.50896) (xy 172.804 115.34764) + (xy 172.804 115.18316) (xy 172.771911 115.02184) (xy 172.708967 114.869879) (xy 172.617587 114.733119) (xy 172.501281 114.616813) + (xy 172.364521 114.525433) (xy 172.21256 114.462489) (xy 172.05124 114.4304) (xy 171.88676 114.4304) (xy 171.72544 114.462489) + (xy 171.573479 114.525433) (xy 171.436719 114.616813) (xy 171.320413 114.733119) (xy 171.229033 114.869879) (xy 171.166089 115.02184) + (xy 171.134 115.18316) (xy 171.134 115.34764) (xy 171.166089 115.50896) (xy 171.209 115.612557) (xy 171.209001 119.921198) + (xy 167.388072 123.742128) (xy 167.388072 122.87) (xy 167.375812 122.745518) (xy 167.339502 122.62582) (xy 167.280537 122.515506) + (xy 167.201185 122.418815) (xy 167.104494 122.339463) (xy 166.99418 122.280498) (xy 166.874482 122.244188) (xy 166.75 122.231928) + (xy 164.956887 122.231928) (xy 165.084609 122.040779) (xy 165.204089 121.752327) (xy 165.265 121.446109) (xy 165.265 121.133891) + (xy 165.204089 120.827673) (xy 165.084609 120.539221) (xy 164.91115 120.279621) (xy 164.690379 120.05885) (xy 164.430779 119.885391) + (xy 164.142327 119.765911) (xy 163.836109 119.705) (xy 163.523891 119.705) (xy 163.217673 119.765911) (xy 163.123303 119.805) + (xy 162.95374 119.805) (xy 162.666842 119.862068) (xy 162.396589 119.97401) (xy 162.153368 120.136525) (xy 161.946525 120.343368) + (xy 161.78401 120.586589) (xy 161.672068 120.856842) (xy 161.615 121.14374) (xy 161.615 121.43626) (xy 161.672068 121.723158) + (xy 161.707988 121.809876) (xy 161.398698 121.937988) (xy 161.176252 122.086622) (xy 161.181817 122.073186) (xy 161.285 121.554449) + (xy 161.285 121.025551) (xy 161.181817 120.506814) (xy 160.979417 120.018175) (xy 160.750114 119.674999) (xy 160.911927 119.674999) + (xy 160.949249 119.678675) (xy 160.986571 119.674999) (xy 160.986582 119.674999) (xy 161.098235 119.664002) (xy 161.241496 119.620545) + (xy 161.373525 119.549973) (xy 161.48925 119.455) (xy 161.513053 119.425996) (xy 166.460999 114.478051) (xy 166.489997 114.454253) + (xy 166.58497 114.338528) (xy 166.655542 114.206499) (xy 166.698999 114.063237) (xy 166.706509 113.986984) (xy 166.752907 113.87497) + (xy 166.754612 113.8664) (xy 183.798742 113.8664) (xy 183.836064 113.870076) (xy 183.873386 113.8664) (xy 183.873397 113.8664) + (xy 183.98505 113.855403) (xy 184.128311 113.811946) (xy 184.26034 113.741374) (xy 184.376065 113.646401) (xy 184.399867 113.617398) + (xy 184.925455 113.09181) (xy 185.029053 113.048899) (xy 185.165813 112.957519) (xy 185.282119 112.841213) (xy 185.373499 112.704453) + (xy 185.436443 112.552492) (xy 185.468532 112.391172) (xy 185.468532 112.226692) (xy 185.436443 112.065372) (xy 185.373499 111.913411) + (xy 185.282119 111.776651) (xy 185.165813 111.660345) (xy 185.029053 111.568965) (xy 184.877092 111.506021) (xy 184.715772 111.473932) + (xy 184.551292 111.473932) (xy 184.389972 111.506021) (xy 184.238011 111.568965) (xy 184.101251 111.660345) (xy 183.984945 111.776651) + (xy 183.893565 111.913411) (xy 183.850654 112.017009) (xy 183.521263 112.3464) (xy 182.378401 112.3464) (xy 185.111003 109.613799) + (xy 185.140001 109.590001) (xy 185.181036 109.54) (xy 185.234974 109.474277) (xy 185.305546 109.342247) (xy 185.320315 109.29356) + (xy 185.349003 109.198986) (xy 185.36 109.087333) (xy 185.36 109.087324) (xy 185.363676 109.050001) (xy 185.36 109.012678) + (xy 185.36 108.918072) (xy 185.75 108.918072) (xy 185.874482 108.905812) (xy 185.99418 108.869502) (xy 186.104494 108.810537) + (xy 186.201185 108.731185) (xy 186.280537 108.634494) (xy 186.339502 108.52418) (xy 186.375812 108.404482) (xy 186.388072 108.28) + (xy 186.388072 106.28) (xy 186.375812 106.155518) (xy 186.339502 106.03582) (xy 186.280537 105.925506) (xy 186.201185 105.828815) + (xy 186.104494 105.749463) (xy 185.99418 105.690498) (xy 185.874482 105.654188) (xy 185.75 105.641928) (xy 183.956887 105.641928) + (xy 184.084609 105.450779) (xy 184.204089 105.162327) (xy 184.265 104.856109) (xy 184.265 104.543891) (xy 184.22146 104.325) + (xy 187.386928 104.325) (xy 187.386928 105.625) (xy 187.399188 105.749482) (xy 187.435498 105.86918) (xy 187.494463 105.979494) + (xy 187.573815 106.076185) (xy 187.670506 106.155537) (xy 187.78082 106.214502) (xy 187.900518 106.250812) (xy 188.025 106.263072) + (xy 188.650908 106.263072) (xy 188.738913 106.394781) (xy 188.855219 106.511087) (xy 188.991979 106.602467) (xy 189.14394 106.665411) + (xy 189.30526 106.6975) (xy 189.46974 106.6975) (xy 189.63106 106.665411) (xy 189.783021 106.602467) (xy 189.919781 106.511087) + (xy 190.036087 106.394781) (xy 190.127467 106.258021) (xy 190.190411 106.10606) (xy 190.2225 105.94474) (xy 190.2225 105.78026) + (xy 190.190411 105.61894) (xy 190.127467 105.466979) (xy 190.036087 105.330219) (xy 189.919781 105.213913) (xy 189.783021 105.122533) + (xy 189.679423 105.079622) (xy 189.613072 105.01327) (xy 189.613072 104.325) (xy 189.600812 104.200518) (xy 189.564502 104.08082) + (xy 189.505537 103.970506) (xy 189.426185 103.873815) (xy 189.329494 103.794463) (xy 189.21918 103.735498) (xy 189.099482 103.699188) + (xy 188.975 103.686928) (xy 188.025 103.686928) (xy 187.900518 103.699188) (xy 187.78082 103.735498) (xy 187.670506 103.794463) + (xy 187.573815 103.873815) (xy 187.494463 103.970506) (xy 187.435498 104.08082) (xy 187.399188 104.200518) (xy 187.386928 104.325) + (xy 184.22146 104.325) (xy 184.204089 104.237673) (xy 184.084609 103.949221) (xy 183.91115 103.689621) (xy 183.690379 103.46885) + (xy 183.430779 103.295391) (xy 183.142327 103.175911) (xy 182.836109 103.115) (xy 182.523891 103.115) (xy 182.217673 103.175911) + (xy 182.123303 103.215) (xy 181.95374 103.215) (xy 181.666842 103.272068) (xy 181.396589 103.38401) (xy 181.153368 103.546525) + (xy 180.946525 103.753368) (xy 180.78401 103.996589) (xy 180.672068 104.266842) (xy 180.615 104.55374) (xy 180.615 104.84626) + (xy 180.672068 105.133158) (xy 180.707988 105.219876) (xy 180.398698 105.347988) (xy 180.176252 105.496622) (xy 180.181817 105.483186) + (xy 180.285 104.964449) (xy 180.285 104.435551) (xy 180.181817 103.916814) (xy 179.979417 103.428175) (xy 179.685576 102.988412) + (xy 179.311588 102.614424) (xy 178.871825 102.320583) (xy 178.725564 102.26) (xy 179.315123 102.26) (xy 179.35 102.263435) + (xy 179.384877 102.26) (xy 179.489184 102.249727) (xy 179.62302 102.209128) (xy 179.746363 102.1432) (xy 179.854475 102.054475) + (xy 179.9432 101.946363) (xy 180.009128 101.82302) (xy 180.049727 101.689184) (xy 180.063435 101.55) (xy 180.06 101.515123) + (xy 180.06 101.213072) (xy 180.8 101.213072) (xy 180.924482 101.200812) (xy 181.04418 101.164502) (xy 181.154494 101.105537) + (xy 181.251185 101.026185) (xy 181.330537 100.929494) (xy 181.389502 100.81918) (xy 181.425812 100.699482) (xy 181.438072 100.575) + (xy 181.438072 99.92573) (xy 181.761004 99.602798) (xy 181.790001 99.579001) (xy 181.884974 99.463276) (xy 181.913356 99.410177) + (xy 181.989967 99.295521) (xy 182.052911 99.14356) (xy 182.085 98.98224) (xy 182.085 98.81776) (xy 182.052911 98.65644) + (xy 181.989967 98.504479) (xy 181.898587 98.367719) (xy 181.782281 98.251413) (xy 181.645521 98.160033) (xy 181.49356 98.097089) + (xy 181.396473 98.077777) (xy 181.435 98.03925) (xy 181.438072 97.825) (xy 181.425812 97.700518) (xy 181.389502 97.58082) + (xy 181.330537 97.470506) (xy 181.251185 97.373815) (xy 181.154494 97.294463) (xy 181.04418 97.235498) (xy 180.924482 97.199188) + (xy 180.8 97.186928) (xy 180.28575 97.19) (xy 180.127002 97.348748) (xy 180.127002 97.19) (xy 180.06 97.19) + (xy 180.06 97.084877) (xy 180.063435 97.05) (xy 180.049727 96.910816) (xy 180.009128 96.77698) (xy 179.9432 96.653637) + (xy 179.854475 96.545525) (xy 179.746363 96.4568) (xy 179.62302 96.390872) (xy 179.489184 96.350273) (xy 179.384877 96.34) + (xy 179.35 96.336565) (xy 179.315123 96.34) (xy 175.884877 96.34) (xy 175.85 96.336565) (xy 175.815123 96.34) + (xy 175.710816 96.350273) (xy 175.57698 96.390872) (xy 175.453637 96.4568) (xy 175.345525 96.545525) (xy 175.2568 96.653637) + (xy 175.190872 96.77698) (xy 175.150273 96.910816) (xy 175.136565 97.05) (xy 175.140001 97.084887) (xy 175.140001 97.186928) + (xy 174.4 97.186928) (xy 174.275518 97.199188) (xy 174.15582 97.235498) (xy 174.045506 97.294463) (xy 173.948815 97.373815) + (xy 173.869463 97.470506) (xy 173.810498 97.58082) (xy 173.798882 97.619111) (xy 173.797753 97.619454) (xy 173.665723 97.690026) + (xy 173.59386 97.749003) (xy 173.549999 97.784999) (xy 173.5262 97.813998) (xy 172.989002 98.351197) (xy 172.959999 98.374999) + (xy 172.919797 98.423986) (xy 172.865026 98.490724) (xy 172.814634 98.585) (xy 172.794454 98.622754) (xy 172.750997 98.766015) + (xy 172.749669 98.779501) (xy 172.697089 98.90644) (xy 172.665 99.06776) (xy 172.665 99.076799) (xy 172.659687 99.078411) + (xy 172.505941 99.160589) (xy 172.371183 99.271183) (xy 172.260589 99.405941) (xy 172.178411 99.559687) (xy 172.127805 99.72651) + (xy 172.110718 99.9) (xy 172.127805 100.07349) (xy 172.178411 100.240313) (xy 172.260589 100.394059) (xy 172.371183 100.528817) + (xy 172.505941 100.639411) (xy 172.659687 100.721589) (xy 172.82651 100.772195) (xy 172.956523 100.785) (xy 173.80013 100.785) + (xy 173.810498 100.81918) (xy 173.869463 100.929494) (xy 173.948815 101.026185) (xy 174.045506 101.105537) (xy 174.15582 101.164502) + (xy 174.275518 101.200812) (xy 174.4 101.213072) (xy 175.14 101.213072) (xy 175.14 101.515123) (xy 175.136565 101.55) + (xy 175.150273 101.689184) (xy 175.190872 101.82302) (xy 175.2568 101.946363) (xy 175.345525 102.054475) (xy 175.430471 102.124188) + (xy 175.453637 102.1432) (xy 175.57698 102.209128) (xy 175.710816 102.249727) (xy 175.85 102.263435) (xy 175.884877 102.26) + (xy 176.474436 102.26) (xy 176.328175 102.320583) (xy 175.888412 102.614424) (xy 175.514424 102.988412) (xy 175.220583 103.428175) + (xy 175.018183 103.916814) (xy 174.915 104.435551) (xy 174.915 104.964449) (xy 175.018183 105.483186) (xy 175.023749 105.496623) + (xy 174.801302 105.347989) (xy 174.492012 105.219877) (xy 174.527932 105.133158) (xy 174.585 104.84626) (xy 174.585 104.55374) + (xy 174.527932 104.266842) (xy 174.41599 103.996589) (xy 174.253475 103.753368) (xy 174.046632 103.546525) (xy 173.803411 103.38401) + (xy 173.533158 103.272068) (xy 173.24626 103.215) (xy 173.076697 103.215) (xy 172.982327 103.175911) (xy 172.676109 103.115) + (xy 172.363891 103.115) (xy 172.057673 103.175911) (xy 171.769221 103.295391) (xy 171.509621 103.46885) (xy 171.28885 103.689621) + (xy 171.115391 103.949221) (xy 170.995911 104.237673) (xy 170.935 104.543891) (xy 170.935 104.856109) (xy 170.995911 105.162327) + (xy 171.115391 105.450779) (xy 171.28885 105.710379) (xy 171.509621 105.93115) (xy 171.769221 106.104609) (xy 171.935016 106.173283) + (xy 171.897988 106.228699) (xy 171.737047 106.617245) (xy 171.655 107.029722) (xy 171.655 107.45028) (xy 171.737047 107.862757) + (xy 171.869252 108.181928) (xy 170.75 108.181928) (xy 170.625518 108.194188) (xy 170.50582 108.230498) (xy 170.395506 108.289463) + (xy 170.336818 108.337627) (xy 170.295521 108.310033) (xy 170.191923 108.267122) (xy 170.01 108.085199) (xy 170.01 105.142683) + (xy 170.079494 105.105537) (xy 170.176185 105.026185) (xy 170.255537 104.929494) (xy 170.314502 104.81918) (xy 170.350812 104.699482) + (xy 170.363072 104.575) (xy 170.363072 103.275) (xy 170.350812 103.150518) (xy 170.314502 103.03082) (xy 170.255537 102.920506) + (xy 170.176185 102.823815) (xy 170.079494 102.744463) (xy 169.96918 102.685498) (xy 169.849482 102.649188) (xy 169.725 102.636928) + (xy 168.775 102.636928) (xy 168.650518 102.649188) (xy 168.53082 102.685498) (xy 168.420506 102.744463) (xy 168.323815 102.823815) + (xy 168.244463 102.920506) (xy 168.185498 103.03082) (xy 168.149188 103.150518) (xy 168.136928 103.275) (xy 168.136928 104.575) + (xy 168.149188 104.699482) (xy 168.185498 104.81918) (xy 168.244463 104.929494) (xy 168.323815 105.026185) (xy 168.420506 105.105537) + (xy 168.49 105.142683) (xy 168.490001 108.362668) (xy 168.486324 108.4) (xy 168.490001 108.437333) (xy 168.500998 108.548986) + (xy 168.50721 108.569463) (xy 168.544454 108.692246) (xy 168.615026 108.824276) (xy 168.675829 108.898364) (xy 168.71 108.940001) + (xy 168.738998 108.963799) (xy 169.117122 109.341923) (xy 169.140001 109.397159) (xy 169.14 110.485673) (xy 169.136324 110.522996) + (xy 169.14 110.560318) (xy 169.14 110.560328) (xy 169.150997 110.671981) (xy 169.19119 110.804482) (xy 169.194454 110.815242) + (xy 169.265026 110.947272) (xy 169.285746 110.972519) (xy 169.359999 111.062997) (xy 169.389003 111.0868) (xy 170.648602 112.3464) + (xy 168.547866 112.3464) (xy 168.624989 112.202113) (xy 168.675595 112.035289) (xy 168.692681 111.8618) (xy 168.675595 111.68831) + (xy 168.624989 111.521487) (xy 168.542811 111.367741) (xy 168.432217 111.232983) (xy 168.297459 111.122389) (xy 168.143713 111.040211) + (xy 167.97689 110.989605) (xy 167.8034 110.972519) (xy 167.727337 110.98001) (xy 166.381513 110.98001) (xy 166.2515 110.992815) + (xy 166.084677 111.043421) (xy 165.930931 111.125599) (xy 165.796173 111.236193) (xy 165.685579 111.370951) (xy 165.603401 111.524697) + (xy 165.552795 111.69152) (xy 165.535708 111.86501) (xy 165.552795 112.0385) (xy 165.603401 112.205323) (xy 165.678807 112.3464) + (xy 163.836311 112.3464) (xy 163.798988 112.342724) (xy 163.761666 112.3464) (xy 163.761655 112.3464) (xy 163.650002 112.357397) + (xy 163.521391 112.39641) (xy 163.500209 112.39641) (xy 163.371598 112.357397) (xy 163.259945 112.3464) (xy 163.259934 112.3464) + (xy 163.222612 112.342724) (xy 163.18529 112.3464) (xy 156.751823 112.3464) (xy 156.7145 112.342724) (xy 156.677177 112.3464) + (xy 156.677168 112.3464) (xy 156.565515 112.357397) (xy 156.422254 112.400854) (xy 156.290225 112.471426) (xy 156.1745 112.566399) + (xy 156.150701 112.595398) (xy 155.688998 113.057102) (xy 155.66 113.0809) (xy 155.636202 113.109898) (xy 155.636201 113.109899) + (xy 155.565026 113.196625) (xy 155.494454 113.328655) (xy 155.472514 113.400984) (xy 155.450998 113.471915) (xy 155.442078 113.562481) + (xy 155.436324 113.620901) (xy 155.440001 113.658233) (xy 155.440001 113.776928) (xy 155.4 113.776928) (xy 155.275518 113.789188) + (xy 155.15582 113.825498) (xy 155.045506 113.884463) (xy 154.948815 113.963815) (xy 154.869463 114.060506) (xy 154.810498 114.17082) + (xy 154.777728 114.278848) (xy 154.775524 114.280026) (xy 154.659799 114.374999) (xy 154.636 114.403998) (xy 154.287602 114.752397) + (xy 154.258599 114.776199) (xy 154.217716 114.826016) (xy 154.1798 114.872216) (xy 154.1798 114.871523) (xy 154.166995 114.74151) + (xy 154.116389 114.574687) (xy 154.034211 114.420941) (xy 153.923617 114.286183) (xy 153.788858 114.175589) (xy 153.635112 114.093411) + (xy 153.468289 114.042805) (xy 153.2948 114.025718) (xy 153.12131 114.042805) (xy 152.954487 114.093411) (xy 152.800741 114.175589) + (xy 152.665983 114.286183) (xy 152.555389 114.420942) (xy 152.473211 114.574688) (xy 152.422605 114.741511) (xy 152.4098 114.871524) + (xy 152.4098 115.492933) (xy 152.405519 115.536402) (xy 152.4098 115.579871) (xy 152.4098 115.579879) (xy 152.420283 115.686314) + (xy 152.422605 115.709892) (xy 152.473212 115.876715) (xy 152.55539 116.030461) (xy 152.638268 116.131448) (xy 152.638271 116.131451) + (xy 152.665984 116.165219) (xy 152.699751 116.192931) (xy 153.830069 117.32325) (xy 153.857782 117.357018) (xy 153.89155 117.384731) + (xy 153.891552 117.384733) (xy 153.954416 117.436324) (xy 153.979629 117.457016) (xy 153.598138 117.838508) (xy 153.5774 117.788443) + (xy 153.5774 117.739222) (xy 153.581076 117.701899) (xy 153.5774 117.664576) (xy 153.5774 117.664568) (xy 153.566403 117.552914) + (xy 153.522946 117.409653) (xy 153.452374 117.277624) (xy 153.357401 117.161899) (xy 153.328397 117.138096) (xy 153.066904 116.876603) + (xy 153.043101 116.847599) (xy 152.927376 116.752626) (xy 152.902137 116.739135) (xy 152.873102 116.64342) (xy 152.814137 116.533106) + (xy 152.734785 116.436415) (xy 152.638094 116.357063) (xy 152.52778 116.298098) (xy 152.408082 116.261788) (xy 152.2836 116.249528) (xy 150.2836 116.249528) (xy 150.159118 116.261788) (xy 150.03942 116.298098) (xy 149.929106 116.357063) (xy 149.832415 116.436415) (xy 149.753063 116.533106) (xy 149.694098 116.64342) (xy 149.657788 116.763118) (xy 149.645528 116.8876) (xy 149.645528 117.8876) (xy 149.657788 118.012082) (xy 149.694098 118.13178) (xy 149.753063 118.242094) (xy 149.769892 118.2626) (xy 149.753063 118.283106) @@ -14733,539 +14736,542 @@ (xy 135.848815 116.373815) (xy 135.769463 116.470506) (xy 135.710498 116.58082) (xy 135.674188 116.700518) (xy 135.661928 116.825) (xy 135.661928 117.1228) (xy 135.53936 117.1228) (xy 135.37804 117.154889) (xy 135.226079 117.217833) (xy 135.089319 117.309213) (xy 134.973013 117.425519) (xy 134.881633 117.562279) (xy 134.818689 117.71424) (xy 134.7866 117.87556) (xy 134.7866 118.04004) - (xy 134.818689 118.20136) (xy 134.881633 118.353321) (xy 134.911001 118.397274) (xy 134.866557 118.504572) (xy 134.834468 118.665892) - (xy 134.834468 118.830372) (xy 134.866557 118.991692) (xy 134.909469 119.095291) (xy 134.909468 120.203545) (xy 134.905792 120.240868) - (xy 134.909468 120.27819) (xy 134.909468 120.2782) (xy 134.920465 120.389853) (xy 134.955944 120.506814) (xy 134.963922 120.533114) - (xy 135.034494 120.665144) (xy 135.065331 120.702718) (xy 135.129467 120.780869) (xy 135.15847 120.804671) (xy 135.7688 121.415002) - (xy 135.792599 121.444001) (xy 135.908324 121.538974) (xy 136.040353 121.609546) (xy 136.183614 121.653003) (xy 136.295267 121.664) - (xy 136.295276 121.664) (xy 136.332599 121.667676) (xy 136.369922 121.664) (xy 137.738836 121.664) (xy 137.414424 121.988412) - (xy 137.120583 122.428175) (xy 136.918183 122.916814) (xy 136.815 123.435551) (xy 136.815 123.964449) (xy 136.918183 124.483186) - (xy 136.923749 124.496623) (xy 136.701302 124.347989) (xy 136.392012 124.219877) (xy 136.427932 124.133158) (xy 136.485 123.84626) - (xy 136.485 123.55374) (xy 136.427932 123.266842) (xy 136.31599 122.996589) (xy 136.153475 122.753368) (xy 135.946632 122.546525) - (xy 135.703411 122.38401) (xy 135.433158 122.272068) (xy 135.14626 122.215) (xy 134.976697 122.215) (xy 134.882327 122.175911) - (xy 134.576109 122.115) (xy 134.263891 122.115) (xy 133.957673 122.175911) (xy 133.669221 122.295391) (xy 133.409621 122.46885) - (xy 133.18885 122.689621) (xy 133.015391 122.949221) (xy 132.895911 123.237673) (xy 132.835 123.543891) (xy 132.835 123.856109) - (xy 132.895911 124.162327) (xy 133.015391 124.450779) (xy 133.18885 124.710379) (xy 133.409621 124.93115) (xy 133.669221 125.104609) - (xy 133.835016 125.173283) (xy 133.797988 125.228699) (xy 133.637047 125.617245) (xy 133.555 126.029722) (xy 133.555 126.45028) - (xy 133.637047 126.862757) (xy 133.769252 127.181928) (xy 132.65 127.181928) (xy 132.525518 127.194188) (xy 132.40582 127.230498) - (xy 132.295506 127.289463) (xy 132.198815 127.368815) (xy 132.119463 127.465506) (xy 132.060498 127.57582) (xy 132.024188 127.695518) - (xy 132.011928 127.82) (xy 132.011928 128.640326) (xy 130.5396 127.167999) (xy 130.5396 122.445157) (xy 130.582511 122.34156) - (xy 130.6146 122.18024) (xy 130.6146 122.01576) (xy 130.582511 121.85444) (xy 130.519567 121.702479) (xy 130.428187 121.565719) - (xy 130.311881 121.449413) (xy 130.175121 121.358033) (xy 130.071522 121.315121) (xy 129.845404 121.089003) (xy 129.821601 121.059999) - (xy 129.705876 120.965026) (xy 129.573847 120.894454) (xy 129.430586 120.850997) (xy 129.318933 120.84) (xy 129.318922 120.84) - (xy 129.2816 120.836324) (xy 129.244278 120.84) (xy 128.767683 120.84) (xy 128.730537 120.770506) (xy 128.651185 120.673815) - (xy 128.554494 120.594463) (xy 128.44418 120.535498) (xy 128.324482 120.499188) (xy 128.2 120.486928) (xy 126.9 120.486928) - (xy 126.775518 120.499188) (xy 126.65582 120.535498) (xy 126.545506 120.594463) (xy 126.448815 120.673815) (xy 126.369463 120.770506) - (xy 126.310498 120.88082) (xy 126.274188 121.000518) (xy 126.261928 121.125) (xy 126.261928 122.075) (xy 126.274188 122.199482) - (xy 126.310498 122.31918) (xy 126.369463 122.429494) (xy 126.448815 122.526185) (xy 126.545506 122.605537) (xy 126.65582 122.664502) - (xy 126.775518 122.700812) (xy 126.9 122.713072) (xy 128.2 122.713072) (xy 128.324482 122.700812) (xy 128.44418 122.664502) - (xy 128.554494 122.605537) (xy 128.651185 122.526185) (xy 128.730537 122.429494) (xy 128.767683 122.36) (xy 128.966799 122.36) - (xy 128.996721 122.389922) (xy 129.0196 122.445157) (xy 129.0196 123.365) (xy 128.91776 123.365) (xy 128.75644 123.397089) - (xy 128.746866 123.401055) (xy 128.730537 123.370506) (xy 128.651185 123.273815) (xy 128.554494 123.194463) (xy 128.44418 123.135498) - (xy 128.324482 123.099188) (xy 128.2 123.086928) (xy 126.9 123.086928) (xy 126.775518 123.099188) (xy 126.65582 123.135498) - (xy 126.545506 123.194463) (xy 126.448815 123.273815) (xy 126.369463 123.370506) (xy 126.310498 123.48082) (xy 126.274188 123.600518) - (xy 126.261928 123.725) (xy 126.261928 124.675) (xy 126.274188 124.799482) (xy 126.310498 124.91918) (xy 126.369463 125.029494) - (xy 126.448815 125.126185) (xy 126.545506 125.205537) (xy 126.65582 125.264502) (xy 126.775518 125.300812) (xy 126.9 125.313072) - (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) (xy 128.554494 125.205537) (xy 128.651185 125.126185) - (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) (xy 128.91776 125.035) (xy 129.019601 125.035) - (xy 129.019601 127.445468) (xy 129.015924 127.4828) (xy 129.019601 127.520133) (xy 129.030598 127.631786) (xy 129.036621 127.651642) - (xy 129.074054 127.775046) (xy 129.144626 127.907076) (xy 129.204773 127.980364) (xy 129.2396 128.022801) (xy 129.268598 128.046599) - (xy 131.841522 130.619524) (xy 131.884433 130.723121) (xy 131.975813 130.859881) (xy 132.092119 130.976187) (xy 132.228879 131.067567) - (xy 132.38084 131.130511) (xy 132.54216 131.1626) (xy 132.70664 131.1626) (xy 132.86796 131.130511) (xy 133.019921 131.067567) - (xy 133.156681 130.976187) (xy 133.272987 130.859881) (xy 133.364367 130.723121) (xy 133.368454 130.713255) (xy 134.1002 131.445002) - (xy 134.123998 131.474) (xy 134.152996 131.497798) (xy 134.239722 131.568973) (xy 134.366218 131.636587) (xy 134.371752 131.639545) - (xy 134.515013 131.683002) (xy 134.626666 131.693999) (xy 134.626675 131.693999) (xy 134.663998 131.697675) (xy 134.701321 131.693999) - (xy 137.473 131.693999) (xy 137.426999 131.74) (xy 126.937322 131.74) (xy 126.899999 131.736324) (xy 126.862676 131.74) - (xy 126.862667 131.74) (xy 126.751014 131.750997) (xy 126.631235 131.787331) (xy 126.607753 131.794454) (xy 126.475723 131.865026) - (xy 126.394815 131.931426) (xy 126.359999 131.959999) (xy 126.336201 131.988997) (xy 125.789234 132.535964) (xy 125.789234 130.57257) - (xy 126.564013 130.364969) (xy 126.68108 130.320908) (xy 126.787302 130.254856) (xy 126.878596 130.169349) (xy 126.951455 130.067675) - (xy 127.003078 129.953741) (xy 127.031481 129.831924) (xy 127.035574 129.706907) (xy 127.015198 129.583494) (xy 126.49756 127.651642) - (xy 126.453499 127.534575) (xy 126.387447 127.428353) (xy 126.30194 127.337059) (xy 126.200266 127.2642) (xy 126.086332 127.212577) - (xy 125.964515 127.184174) (xy 125.839498 127.180081) (xy 125.716085 127.200457) (xy 123.982326 127.665016) (xy 124.030992 127.547526) - (xy 124.091903 127.241308) (xy 124.091903 126.92909) (xy 124.030992 126.622872) (xy 123.911512 126.33442) (xy 123.738053 126.07482) - (xy 123.517282 125.854049) (xy 123.257682 125.68059) (xy 122.96923 125.56111) (xy 122.663012 125.500199) (xy 122.350794 125.500199) - (xy 122.044576 125.56111) (xy 121.756124 125.68059) (xy 121.588772 125.792411) (xy 121.513508 125.807382) (xy 121.243255 125.919324) - (xy 121.000034 126.081839) (xy 120.793191 126.288682) (xy 120.630676 126.531903) (xy 120.518734 126.802156) (xy 120.461666 127.089054) - (xy 120.461666 127.381574) (xy 120.518734 127.668472) (xy 120.630676 127.938725) (xy 120.738829 128.100587) (xy 120.576595 128.208988) - (xy 120.285 128.500583) (xy 120.285 128.135551) (xy 120.181817 127.616814) (xy 119.979417 127.128175) (xy 119.685576 126.688412) - (xy 119.660219 126.663055) (xy 119.75644 126.702911) (xy 119.91776 126.735) (xy 120.08224 126.735) (xy 120.24356 126.702911) - (xy 120.395521 126.639967) (xy 120.532281 126.548587) (xy 120.648587 126.432281) (xy 120.739967 126.295521) (xy 120.802911 126.14356) - (xy 120.835 125.98224) (xy 120.835 125.81776) (xy 120.802911 125.65644) (xy 120.739967 125.504479) (xy 120.648587 125.367719) - (xy 120.532281 125.251413) (xy 120.511776 125.237712) (xy 120.539967 125.195521) (xy 120.602911 125.04356) (xy 120.635 124.88224) - (xy 120.635 124.71776) (xy 120.602911 124.55644) (xy 120.56 124.452843) (xy 120.56 124.427565) (xy 120.563676 124.390242) - (xy 120.56 124.352919) (xy 120.56 124.352911) (xy 120.549003 124.241257) (xy 120.505546 124.097996) (xy 120.434974 123.965967) - (xy 120.340001 123.850242) (xy 120.311003 123.826444) (xy 120.236894 123.752335) (xy 120.255947 123.67062) (xy 120.26004 123.545603) - (xy 120.239664 123.42219) (xy 120.15787 123.116931) (xy 120.291923 122.982878) (xy 120.395521 122.939967) (xy 120.532281 122.848587) - (xy 120.648587 122.732281) (xy 120.739967 122.595521) (xy 120.802911 122.44356) (xy 120.835 122.28224) (xy 120.835 122.11776) - (xy 120.802911 121.95644) (xy 120.739967 121.804479) (xy 120.648587 121.667719) (xy 120.631228 121.65036) (xy 121.8976 121.65036) - (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.992633 122.128121) (xy 122.084013 122.264881) (xy 122.200319 122.381187) - (xy 122.337079 122.472567) (xy 122.482012 122.5326) (xy 122.337079 122.592633) (xy 122.200319 122.684013) (xy 122.084013 122.800319) - (xy 121.992633 122.937079) (xy 121.929689 123.08904) (xy 121.8976 123.25036) (xy 121.8976 123.41484) (xy 121.929689 123.57616) - (xy 121.9726 123.679757) (xy 121.9726 123.895278) (xy 121.968924 123.9326) (xy 121.9726 123.969922) (xy 121.9726 123.969932) - (xy 121.983597 124.081585) (xy 122.021393 124.206185) (xy 122.027054 124.224846) (xy 122.097626 124.356876) (xy 122.135817 124.403411) - (xy 122.192599 124.472601) (xy 122.221603 124.496404) (xy 122.436196 124.710997) (xy 122.459999 124.740001) (xy 122.575724 124.834974) - (xy 122.707753 124.905546) (xy 122.762007 124.922004) (xy 122.819463 125.029494) (xy 122.898815 125.126185) (xy 122.995506 125.205537) - (xy 123.10582 125.264502) (xy 123.225518 125.300812) (xy 123.35 125.313072) (xy 124.65 125.313072) (xy 124.774482 125.300812) - (xy 124.89418 125.264502) (xy 125.004494 125.205537) (xy 125.101185 125.126185) (xy 125.180537 125.029494) (xy 125.239502 124.91918) - (xy 125.275812 124.799482) (xy 125.288072 124.675) (xy 125.288072 123.725) (xy 125.275812 123.600518) (xy 125.239502 123.48082) - (xy 125.180537 123.370506) (xy 125.101185 123.273815) (xy 125.004494 123.194463) (xy 124.89418 123.135498) (xy 124.774482 123.099188) - (xy 124.65 123.086928) (xy 123.534636 123.086928) (xy 123.472567 122.937079) (xy 123.381187 122.800319) (xy 123.287816 122.706948) - (xy 123.35 122.713072) (xy 124.65 122.713072) (xy 124.774482 122.700812) (xy 124.89418 122.664502) (xy 125.004494 122.605537) - (xy 125.101185 122.526185) (xy 125.180537 122.429494) (xy 125.239502 122.31918) (xy 125.275812 122.199482) (xy 125.288072 122.075) - (xy 125.288072 121.125) (xy 125.275812 121.000518) (xy 125.239502 120.88082) (xy 125.180537 120.770506) (xy 125.101185 120.673815) - (xy 125.004494 120.594463) (xy 124.89418 120.535498) (xy 124.774482 120.499188) (xy 124.65 120.486928) (xy 123.35 120.486928) - (xy 123.225518 120.499188) (xy 123.10582 120.535498) (xy 122.995506 120.594463) (xy 122.898815 120.673815) (xy 122.819463 120.770506) - (xy 122.779786 120.844736) (xy 122.716214 120.850997) (xy 122.572953 120.894454) (xy 122.517699 120.923988) (xy 122.48904 120.929689) - (xy 122.337079 120.992633) (xy 122.200319 121.084013) (xy 122.084013 121.200319) (xy 121.992633 121.337079) (xy 121.929689 121.48904) - (xy 121.8976 121.65036) (xy 120.631228 121.65036) (xy 120.532281 121.551413) (xy 120.395521 121.460033) (xy 120.24356 121.397089) - (xy 120.08224 121.365) (xy 119.91776 121.365) (xy 119.75644 121.397089) (xy 119.610392 121.457584) (xy 119.533884 121.413412) - (xy 118.423794 121.71086) (xy 118.42897 121.730178) (xy 118.41826 121.733048) (xy 118.342167 121.449065) (xy 118.352878 121.446195) - (xy 118.358054 121.465514) (xy 119.468144 121.168067) (xy 119.580397 120.973638) (xy 119.527912 120.765894) (xy 119.483852 120.648826) - (xy 119.417799 120.542605) (xy 119.332292 120.451311) (xy 119.230618 120.378452) (xy 119.116684 120.32683) (xy 118.994868 120.298425) - (xy 118.86985 120.294333) (xy 118.746437 120.314709) (xy 118.250505 120.450774) (xy 118.138253 120.645199) (xy 118.097166 120.491861) - (xy 118.086453 120.494731) (xy 118.027859 120.276054) (xy 118.022151 120.241484) (xy 118.009809 120.208692) (xy 118.009807 120.208684) - (xy 117.972887 120.11059) (xy 117.899032 119.991823) (xy 117.803427 119.889746) (xy 117.689744 119.808281) (xy 117.562352 119.750561) - (xy 117.426149 119.718803) (xy 117.286366 119.714227) (xy 117.286365 119.714227) (xy 117.182953 119.7313) (xy 117.182948 119.731301) - (xy 117.148377 119.737009) (xy 117.115583 119.749352) (xy 116.935 119.797739) (xy 116.935 119.71776) (xy 116.902911 119.55644) - (xy 116.839967 119.404479) (xy 116.748587 119.267719) (xy 116.632281 119.151413) (xy 116.495521 119.060033) (xy 116.34356 118.997089) - (xy 116.18224 118.965) (xy 116.01776 118.965) (xy 115.85644 118.997089) (xy 115.752843 119.04) (xy 114.91455 119.04) - (xy 114.877217 119.036323) (xy 114.839884 119.04) (xy 114.728231 119.050997) (xy 114.58497 119.094454) (xy 114.452941 119.165026) - (xy 114.337216 119.259999) (xy 114.313418 119.288997) (xy 113.555582 120.046834) (xy 113.639967 119.920542) (xy 113.702911 119.768581) - (xy 113.735 119.607261) (xy 113.735 119.442781) (xy 113.702911 119.281461) (xy 113.639967 119.1295) (xy 113.548587 118.99274) - (xy 113.515847 118.96) (xy 121.638999 118.96) (xy 121.990922 119.311923) (xy 122.033833 119.415521) (xy 122.125213 119.552281) - (xy 122.241519 119.668587) (xy 122.378279 119.759967) (xy 122.53024 119.822911) (xy 122.69156 119.855) (xy 122.853982 119.855) - (xy 122.928815 119.946185) (xy 123.025506 120.025537) (xy 123.13582 120.084502) (xy 123.255518 120.120812) (xy 123.38 120.133072) - (xy 124.68 120.133072) (xy 124.804482 120.120812) (xy 124.92418 120.084502) (xy 125.034494 120.025537) (xy 125.131185 119.946185) - (xy 125.210537 119.849494) (xy 125.269502 119.73918) (xy 125.305812 119.619482) (xy 125.318072 119.495) (xy 125.318072 119.25) - (xy 125.34064 119.25) (xy 125.50196 119.217911) (xy 125.653921 119.154967) (xy 125.790681 119.063587) (xy 125.906987 118.947281) - (xy 125.998367 118.810521) (xy 126.061311 118.65856) (xy 126.083899 118.545) (xy 126.291928 118.545) (xy 126.291928 119.495) - (xy 126.304188 119.619482) (xy 126.340498 119.73918) (xy 126.399463 119.849494) (xy 126.478815 119.946185) (xy 126.575506 120.025537) - (xy 126.68582 120.084502) (xy 126.805518 120.120812) (xy 126.93 120.133072) (xy 128.23 120.133072) (xy 128.354482 120.120812) - (xy 128.47418 120.084502) (xy 128.584494 120.025537) (xy 128.681185 119.946185) (xy 128.756018 119.855) (xy 128.76504 119.855) - (xy 128.92636 119.822911) (xy 129.078321 119.759967) (xy 129.215081 119.668587) (xy 129.331387 119.552281) (xy 129.422767 119.415521) - (xy 129.485711 119.26356) (xy 129.5178 119.10224) (xy 129.5178 118.93776) (xy 129.485711 118.77644) (xy 129.422767 118.624479) - (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) (xy 128.92636 118.217089) (xy 128.76504 118.185) - (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) (xy 128.47418 117.955498) (xy 128.354482 117.919188) - (xy 128.23 117.906928) (xy 126.93 117.906928) (xy 126.805518 117.919188) (xy 126.68582 117.955498) (xy 126.575506 118.014463) - (xy 126.478815 118.093815) (xy 126.399463 118.190506) (xy 126.340498 118.30082) (xy 126.304188 118.420518) (xy 126.291928 118.545) - (xy 126.083899 118.545) (xy 126.0934 118.49724) (xy 126.0934 118.33276) (xy 126.061311 118.17144) (xy 125.998367 118.019479) - (xy 125.9676 117.973433) (xy 125.9676 117.475157) (xy 126.010511 117.37156) (xy 126.032383 117.261602) (xy 129.99428 117.261602) - (xy 130.031602 117.265278) (xy 130.068924 117.261602) (xy 130.068935 117.261602) (xy 130.180588 117.250605) (xy 130.323849 117.207148) - (xy 130.455878 117.136576) (xy 130.571603 117.041603) (xy 130.595405 117.0126) (xy 131.284549 116.323456) (xy 131.313548 116.299658) - (xy 131.408521 116.183933) (xy 131.479093 116.051904) (xy 131.52255 115.908643) (xy 131.533547 115.79699) (xy 131.533547 115.796982) - (xy 131.537223 115.759657) (xy 131.533547 115.722332) (xy 131.533547 113.975704) (xy 131.576458 113.872107) (xy 131.608547 113.710787) - (xy 131.608547 113.546307) (xy 131.576458 113.384987) (xy 131.513514 113.233026) (xy 131.422134 113.096266) (xy 131.305828 112.97996) - (xy 131.169068 112.88858) (xy 131.017107 112.825636) (xy 130.855787 112.793547) (xy 130.691307 112.793547) (xy 130.529987 112.825636) - (xy 130.378026 112.88858) (xy 130.241266 112.97996) (xy 130.12496 113.096266) (xy 130.03358 113.233026) (xy 129.970636 113.384987) - (xy 129.938547 113.546307) (xy 129.938547 113.710787) (xy 129.970636 113.872107) (xy 130.013547 113.975704) (xy 130.013547 114.163745) - (xy 128.807879 112.958077) (xy 128.764967 112.854479) (xy 128.673587 112.717719) (xy 128.557281 112.601413) (xy 128.420521 112.510033) - (xy 128.26856 112.447089) (xy 128.26 112.445386) (xy 128.26 111.318072) (xy 128.65 111.318072) (xy 128.774482 111.305812) - (xy 128.89418 111.269502) (xy 129.004494 111.210537) (xy 129.101185 111.131185) (xy 129.180537 111.034494) (xy 129.239502 110.92418) - (xy 129.275812 110.804482) (xy 129.288072 110.68) (xy 129.288072 108.68) (xy 129.275812 108.555518) (xy 129.239502 108.43582) - (xy 129.180537 108.325506) (xy 129.101185 108.228815) (xy 129.004494 108.149463) (xy 128.89418 108.090498) (xy 128.774482 108.054188) - (xy 128.65 108.041928) (xy 126.856887 108.041928) (xy 126.984609 107.850779) (xy 127.104089 107.562327) (xy 127.165 107.256109) - (xy 127.165 106.943891) (xy 127.104089 106.637673) (xy 126.984609 106.349221) (xy 126.81115 106.089621) (xy 126.590379 105.86885) - (xy 126.330779 105.695391) (xy 126.042327 105.575911) (xy 125.736109 105.515) (xy 125.423891 105.515) (xy 125.117673 105.575911) - (xy 125.023303 105.615) (xy 124.85374 105.615) (xy 124.566842 105.672068) (xy 124.296589 105.78401) (xy 124.053368 105.946525) - (xy 123.846525 106.153368) (xy 123.68401 106.396589) (xy 123.572068 106.666842) (xy 123.515 106.95374) (xy 123.515 107.24626) - (xy 123.572068 107.533158) (xy 123.607988 107.619876) (xy 123.298698 107.747988) (xy 123.076252 107.896622) (xy 123.081817 107.883186) - (xy 123.185 107.364449) (xy 123.185 106.835551) (xy 123.081817 106.316814) (xy 122.879417 105.828175) (xy 122.585576 105.388412) - (xy 122.211588 105.014424) (xy 121.771825 104.720583) (xy 121.384142 104.56) (xy 122.215123 104.56) (xy 122.25 104.563435) - (xy 122.284877 104.56) (xy 122.389184 104.549727) (xy 122.52302 104.509128) (xy 122.646363 104.4432) (xy 122.754475 104.354475) - (xy 122.8432 104.246363) (xy 122.909128 104.12302) (xy 122.949727 103.989184) (xy 122.963435 103.85) (xy 122.96 103.815123) - (xy 122.96 103.613072) (xy 123.7 103.613072) (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) - (xy 124.151185 103.426185) (xy 124.230537 103.329494) (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) - (xy 124.338072 102.686729) (xy 124.741923 102.282878) (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) - (xy 125.189967 101.895521) (xy 125.252911 101.74356) (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) - (xy 125.189967 101.104479) (xy 125.098587 100.967719) (xy 124.982281 100.851413) (xy 124.845521 100.760033) (xy 124.69356 100.697089) - (xy 124.53224 100.665) (xy 124.36776 100.665) (xy 124.335 100.671516) (xy 124.335 100.597998) (xy 124.176252 100.597998) - (xy 124.335 100.43925) (xy 124.338072 100.225) (xy 124.325812 100.100518) (xy 124.289502 99.98082) (xy 124.230537 99.870506) - (xy 124.151185 99.773815) (xy 124.054494 99.694463) (xy 123.94418 99.635498) (xy 123.824482 99.599188) (xy 123.7 99.586928) - (xy 123.18575 99.59) (xy 123.027002 99.748748) (xy 123.027002 99.59) (xy 122.96 99.59) (xy 122.96 99.439) - (xy 126.257197 99.439) (xy 128.726203 101.908008) (xy 128.749997 101.937001) (xy 128.77899 101.960795) (xy 128.778994 101.960799) - (xy 128.831241 102.003676) (xy 128.865722 102.031974) (xy 128.997751 102.102546) (xy 129.141012 102.146003) (xy 129.252665 102.157) - (xy 129.252674 102.157) (xy 129.289997 102.160676) (xy 129.326263 102.157104) (xy 129.355665 102.16) (xy 129.402843 102.16) - (xy 129.50644 102.202911) (xy 129.66776 102.235) (xy 129.83224 102.235) (xy 129.912691 102.218997) (xy 129.935498 102.29418) - (xy 129.994463 102.404494) (xy 130.073815 102.501185) (xy 130.170506 102.580537) (xy 130.28082 102.639502) (xy 130.400518 102.675812) - (xy 130.525 102.688072) (xy 131.475 102.688072) (xy 131.599482 102.675812) (xy 131.71918 102.639502) (xy 131.829494 102.580537) - (xy 131.926185 102.501185) (xy 132.005537 102.404494) (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) - (xy 132.113072 101.982618) (xy 132.165001 101.940001) (xy 132.188803 101.910998) (xy 134.011009 100.088794) (xy 134.040001 100.065001) - (xy 134.063795 100.036008) (xy 134.063799 100.036004) (xy 134.134973 99.949277) (xy 134.134974 99.949276) (xy 134.205546 99.817247) - (xy 134.249003 99.673986) (xy 134.249136 99.672634) (xy 134.26059 99.694063) (xy 134.343468 99.79505) (xy 135.118466 100.570049) - (xy 135.146179 100.603817) (xy 135.179947 100.63153) (xy 135.179949 100.631532) (xy 135.25983 100.697089) (xy 135.280937 100.714411) - (xy 135.434683 100.796589) (xy 135.601506 100.847195) (xy 135.731519 100.86) (xy 135.731527 100.86) (xy 135.732361 100.860082) - (xy 135.769463 100.929494) (xy 135.848815 101.026185) (xy 135.945506 101.105537) (xy 136.05582 101.164502) (xy 136.175518 101.200812) - (xy 136.3 101.213072) (xy 137.04 101.213072) (xy 137.04 101.515123) (xy 137.036565 101.55) (xy 137.050273 101.689184) - (xy 137.090872 101.82302) (xy 137.1568 101.946363) (xy 137.245525 102.054475) (xy 137.330471 102.124188) (xy 137.353637 102.1432) - (xy 137.47698 102.209128) (xy 137.610816 102.249727) (xy 137.75 102.263435) (xy 137.784877 102.26) (xy 138.374436 102.26) - (xy 138.228175 102.320583) (xy 137.788412 102.614424) (xy 137.414424 102.988412) (xy 137.120583 103.428175) (xy 136.918183 103.916814) - (xy 136.815 104.435551) (xy 136.815 104.964449) (xy 136.918183 105.483186) (xy 136.923749 105.496623) (xy 136.701302 105.347989) - (xy 136.392012 105.219877) (xy 136.427932 105.133158) (xy 136.485 104.84626) (xy 136.485 104.55374) (xy 136.427932 104.266842) - (xy 136.31599 103.996589) (xy 136.153475 103.753368) (xy 135.946632 103.546525) (xy 135.703411 103.38401) (xy 135.433158 103.272068) - (xy 135.14626 103.215) (xy 134.976697 103.215) (xy 134.882327 103.175911) (xy 134.576109 103.115) (xy 134.263891 103.115) - (xy 133.957673 103.175911) (xy 133.669221 103.295391) (xy 133.409621 103.46885) (xy 133.18885 103.689621) (xy 133.015391 103.949221) - (xy 132.895911 104.237673) (xy 132.835 104.543891) (xy 132.835 104.856109) (xy 132.895911 105.162327) (xy 133.015391 105.450779) - (xy 133.18885 105.710379) (xy 133.409621 105.93115) (xy 133.669221 106.104609) (xy 133.835016 106.173283) (xy 133.797988 106.228699) - (xy 133.637047 106.617245) (xy 133.555 107.029722) (xy 133.555 107.45028) (xy 133.637047 107.862757) (xy 133.769252 108.181928) - (xy 132.65 108.181928) (xy 132.56 108.190792) (xy 132.56 105.787323) (xy 132.563676 105.75) (xy 132.56 105.712677) - (xy 132.56 105.612667) (xy 132.549003 105.501014) (xy 132.505546 105.357753) (xy 132.434974 105.225724) (xy 132.340001 105.109999) - (xy 132.224276 105.015026) (xy 132.113072 104.955585) (xy 132.113072 104.3) (xy 132.100812 104.175518) (xy 132.064502 104.05582) - (xy 132.005537 103.945506) (xy 131.926185 103.848815) (xy 131.829494 103.769463) (xy 131.71918 103.710498) (xy 131.599482 103.674188) - (xy 131.475 103.661928) (xy 130.525 103.661928) (xy 130.400518 103.674188) (xy 130.28082 103.710498) (xy 130.170506 103.769463) - (xy 130.073815 103.848815) (xy 129.994463 103.945506) (xy 129.935498 104.05582) (xy 129.899188 104.175518) (xy 129.886928 104.3) - (xy 129.886928 105.6) (xy 129.899188 105.724482) (xy 129.935498 105.84418) (xy 129.994463 105.954494) (xy 130.073815 106.051185) - (xy 130.170506 106.130537) (xy 130.28082 106.189502) (xy 130.400518 106.225812) (xy 130.525 106.238072) (xy 131.040001 106.238072) - (xy 131.04 108.602843) (xy 130.997089 108.70644) (xy 130.965 108.86776) (xy 130.965 109.03224) (xy 130.997089 109.19356) - (xy 131.040001 109.297159) (xy 131.04 111.712679) (xy 131.036324 111.750002) (xy 131.04 111.787324) (xy 131.04 111.787334) - (xy 131.050997 111.898987) (xy 131.083592 112.00644) (xy 131.094454 112.042248) (xy 131.165026 112.174278) (xy 131.19736 112.213677) - (xy 131.259999 112.290003) (xy 131.289002 112.313805) (xy 131.961204 112.986009) (xy 131.984998 113.015002) (xy 132.013991 113.038796) - (xy 132.013995 113.0388) (xy 132.064198 113.08) (xy 132.100723 113.109975) (xy 132.232752 113.180547) (xy 132.376013 113.224004) - (xy 132.487666 113.235001) (xy 132.487675 113.235001) (xy 132.524998 113.238677) (xy 132.562321 113.235001) (xy 145.487677 113.235001) - (xy 145.524999 113.238677) (xy 145.562321 113.235001) (xy 145.562332 113.235001) (xy 145.673985 113.224004) (xy 145.817246 113.180547) - (xy 145.949275 113.109975) (xy 146.065 113.015002) (xy 146.068071 113.01126) (xy 151.565 113.01126) (xy 151.565 113.17574) - (xy 151.597089 113.33706) (xy 151.660033 113.489021) (xy 151.751413 113.625781) (xy 151.867719 113.742087) (xy 152.004479 113.833467) - (xy 152.15644 113.896411) (xy 152.31776 113.9285) (xy 152.48224 113.9285) (xy 152.64356 113.896411) (xy 152.795521 113.833467) - (xy 152.860275 113.7902) (xy 154.339043 113.7902) (xy 154.44264 113.833111) (xy 154.60396 113.8652) (xy 154.76844 113.8652) - (xy 154.92976 113.833111) (xy 155.081721 113.770167) (xy 155.218481 113.678787) (xy 155.334787 113.562481) (xy 155.426167 113.425721) - (xy 155.489111 113.27376) (xy 155.5212 113.11244) (xy 155.5212 112.94796) (xy 155.489111 112.78664) (xy 155.426167 112.634679) - (xy 155.334787 112.497919) (xy 155.218481 112.381613) (xy 155.081721 112.290233) (xy 154.92976 112.227289) (xy 154.76844 112.1952) - (xy 154.60396 112.1952) (xy 154.44264 112.227289) (xy 154.339043 112.2702) (xy 152.541059 112.2702) (xy 152.48224 112.2585) - (xy 152.31776 112.2585) (xy 152.15644 112.290589) (xy 152.004479 112.353533) (xy 151.867719 112.444913) (xy 151.751413 112.561219) - (xy 151.660033 112.697979) (xy 151.597089 112.84994) (xy 151.565 113.01126) (xy 146.068071 113.01126) (xy 146.088803 112.985999) - (xy 147.011003 112.063799) (xy 147.040001 112.040001) (xy 147.134974 111.924276) (xy 147.205546 111.792247) (xy 147.249003 111.648986) - (xy 147.26 111.537333) (xy 147.26 111.537325) (xy 147.263676 111.5) (xy 147.26 111.462675) (xy 147.26 108.918072) - (xy 147.65 108.918072) (xy 147.774482 108.905812) (xy 147.89418 108.869502) (xy 148.004494 108.810537) (xy 148.101185 108.731185) - (xy 148.180537 108.634494) (xy 148.239502 108.52418) (xy 148.275812 108.404482) (xy 148.288072 108.28) (xy 148.288072 106.28) - (xy 148.275812 106.155518) (xy 148.239502 106.03582) (xy 148.180537 105.925506) (xy 148.101185 105.828815) (xy 148.004494 105.749463) - (xy 147.89418 105.690498) (xy 147.774482 105.654188) (xy 147.65 105.641928) (xy 145.856887 105.641928) (xy 145.984609 105.450779) - (xy 146.104089 105.162327) (xy 146.165 104.856109) (xy 146.165 104.543891) (xy 146.104089 104.237673) (xy 145.984609 103.949221) - (xy 145.81115 103.689621) (xy 145.590379 103.46885) (xy 145.330779 103.295391) (xy 145.042327 103.175911) (xy 144.736109 103.115) - (xy 144.423891 103.115) (xy 144.117673 103.175911) (xy 144.023303 103.215) (xy 143.85374 103.215) (xy 143.566842 103.272068) - (xy 143.296589 103.38401) (xy 143.053368 103.546525) (xy 142.846525 103.753368) (xy 142.68401 103.996589) (xy 142.572068 104.266842) - (xy 142.515 104.55374) (xy 142.515 104.84626) (xy 142.572068 105.133158) (xy 142.607988 105.219876) (xy 142.298698 105.347988) - (xy 142.076252 105.496622) (xy 142.081817 105.483186) (xy 142.185 104.964449) (xy 142.185 104.435551) (xy 142.081817 103.916814) - (xy 141.879417 103.428175) (xy 141.585576 102.988412) (xy 141.211588 102.614424) (xy 140.771825 102.320583) (xy 140.625564 102.26) - (xy 141.215123 102.26) (xy 141.25 102.263435) (xy 141.284877 102.26) (xy 141.389184 102.249727) (xy 141.52302 102.209128) - (xy 141.646363 102.1432) (xy 141.754475 102.054475) (xy 141.8432 101.946363) (xy 141.909128 101.82302) (xy 141.949727 101.689184) - (xy 141.963435 101.55) (xy 141.96 101.515123) (xy 141.96 101.213072) (xy 142.7 101.213072) (xy 142.824482 101.200812) - (xy 142.94418 101.164502) (xy 143.054494 101.105537) (xy 143.151185 101.026185) (xy 143.230537 100.929494) (xy 143.289502 100.81918) - (xy 143.325812 100.699482) (xy 143.330979 100.647014) (xy 143.400276 100.609974) (xy 143.516001 100.515001) (xy 143.539803 100.485998) - (xy 144.111004 99.914798) (xy 144.140001 99.891001) (xy 144.234974 99.775276) (xy 144.305546 99.643247) (xy 144.349003 99.499986) - (xy 144.35886 99.39991) (xy 144.402911 99.29356) (xy 144.435 99.13224) (xy 144.435 98.96776) (xy 144.402911 98.80644) - (xy 144.339967 98.654479) (xy 144.248587 98.517719) (xy 144.132281 98.401413) (xy 143.995521 98.310033) (xy 143.84356 98.247089) - (xy 143.68224 98.215) (xy 143.51776 98.215) (xy 143.35644 98.247089) (xy 143.335 98.25597) (xy 143.335 98.197998) - (xy 143.176252 98.197998) (xy 143.335 98.03925) (xy 143.338072 97.825) (xy 143.325812 97.700518) (xy 143.289502 97.58082) - (xy 143.230537 97.470506) (xy 143.151185 97.373815) (xy 143.054494 97.294463) (xy 142.94418 97.235498) (xy 142.824482 97.199188) - (xy 142.7 97.186928) (xy 142.18575 97.19) (xy 142.027002 97.348748) (xy 142.027002 97.19) (xy 141.96 97.19) - (xy 141.96 97.084877) (xy 141.963435 97.05) (xy 141.949727 96.910816) (xy 141.909128 96.77698) (xy 141.8432 96.653637) - (xy 141.754475 96.545525) (xy 141.646363 96.4568) (xy 141.52302 96.390872) (xy 141.389184 96.350273) (xy 141.284877 96.34) - (xy 141.25 96.336565) (xy 141.215123 96.34) (xy 137.784877 96.34) (xy 137.75 96.336565) (xy 137.715123 96.34) - (xy 137.610816 96.350273) (xy 137.47698 96.390872) (xy 137.353637 96.4568) (xy 137.245525 96.545525) (xy 137.1568 96.653637) - (xy 137.090872 96.77698) (xy 137.050273 96.910816) (xy 137.036565 97.05) (xy 137.040001 97.084887) (xy 137.040001 97.186928) - (xy 136.3 97.186928) (xy 136.175518 97.199188) (xy 136.05582 97.235498) (xy 135.945506 97.294463) (xy 135.848815 97.373815) - (xy 135.769463 97.470506) (xy 135.757338 97.493189) (xy 135.670753 97.519454) (xy 135.538724 97.590026) (xy 135.422999 97.684999) - (xy 135.399196 97.714003) (xy 135.189013 97.924186) (xy 135.160009 97.947989) (xy 135.112781 98.005537) (xy 135.065036 98.063714) - (xy 135.001431 98.182709) (xy 134.994464 98.195744) (xy 134.958342 98.314826) (xy 134.82651 98.327809) (xy 134.659687 98.378416) - (xy 134.505941 98.460594) (xy 134.371183 98.571187) (xy 134.26059 98.705945) (xy 134.26 98.707049) (xy 134.26 96.614801) - (xy 135.859999 95.014804) (xy 135.860008 95.014793) (xy 135.964801 94.91) (xy 149.240001 94.91) (xy 149.240001 95.572317) - (xy 149.170506 95.609463) (xy 149.073815 95.688815) (xy 148.994463 95.785506) (xy 148.935498 95.89582) (xy 148.899188 96.015518) - (xy 148.886928 96.14) (xy 148.886928 97.44) (xy 148.899188 97.564482) (xy 148.935498 97.68418) (xy 148.994463 97.794494) - (xy 149.073815 97.891185) (xy 149.165 97.966018) (xy 149.165 98.02224) (xy 149.197089 98.18356) (xy 149.260033 98.335521) - (xy 149.351413 98.472281) (xy 149.467719 98.588587) (xy 149.604479 98.679967) (xy 149.75644 98.742911) (xy 149.91776 98.775) - (xy 150.08224 98.775) (xy 150.24356 98.742911) (xy 150.395521 98.679967) (xy 150.532281 98.588587) (xy 150.648587 98.472281) - (xy 150.739967 98.335521) (xy 150.802911 98.18356) (xy 150.835 98.02224) (xy 150.835 97.966018) (xy 150.926185 97.891185) - (xy 151.005537 97.794494) (xy 151.064502 97.68418) (xy 151.100812 97.564482) (xy 151.113072 97.44) (xy 151.113072 96.14) - (xy 151.100812 96.015518) (xy 151.064502 95.89582) (xy 151.005537 95.785506) (xy 150.926185 95.688815) (xy 150.829494 95.609463) - (xy 150.76 95.572317) (xy 150.76 94.459601) (xy 151.546402 93.6732) (xy 154.487453 93.6732) (xy 154.524775 93.676876) - (xy 154.562097 93.6732) (xy 154.562108 93.6732) (xy 154.673761 93.662203) (xy 154.817022 93.618746) (xy 154.949051 93.548174) - (xy 154.969378 93.531492) (xy 155.004479 93.554946) (xy 155.108077 93.597858) (xy 155.440001 93.929782) (xy 155.440001 94.676928) - (xy 155.4 94.676928) (xy 155.275518 94.689188) (xy 155.15582 94.725498) (xy 155.045506 94.784463) (xy 154.948815 94.863815) - (xy 154.869463 94.960506) (xy 154.810498 95.07082) (xy 154.774188 95.190518) (xy 154.761928 95.315) (xy 154.761928 95.705) - (xy 154.66776 95.705) (xy 154.50644 95.737089) (xy 154.457685 95.757284) (xy 154.378817 95.661183) (xy 154.244059 95.550589) - (xy 154.090313 95.468411) (xy 153.92349 95.417805) (xy 153.75 95.400718) (xy 153.576511 95.417805) (xy 153.409688 95.468411) - (xy 153.255942 95.550589) (xy 153.121183 95.661183) (xy 153.010589 95.795941) (xy 152.928411 95.949687) (xy 152.877805 96.11651) - (xy 152.865 96.246523) (xy 152.865 96.458533) (xy 152.860719 96.502002) (xy 152.865 96.545471) (xy 152.865 96.545478) - (xy 152.875085 96.647877) (xy 152.877805 96.675492) (xy 152.884989 96.699173) (xy 152.928411 96.842314) (xy 153.010589 96.99606) - (xy 153.121183 97.130819) (xy 153.154956 97.158536) (xy 154.156468 98.160049) (xy 154.184181 98.193817) (xy 154.217949 98.22153) - (xy 154.217951 98.221532) (xy 154.262088 98.257754) (xy 154.318939 98.304411) (xy 154.472685 98.386589) (xy 154.639508 98.437195) - (xy 154.769521 98.45) (xy 154.769531 98.45) (xy 154.812997 98.454281) (xy 154.856463 98.45) (xy 154.894499 98.45) - (xy 154.948815 98.516185) (xy 155.045506 98.595537) (xy 155.15582 98.654502) (xy 155.275518 98.690812) (xy 155.315001 98.694701) - (xy 155.315001 99.101521) (xy 155.310719 99.145) (xy 155.327805 99.31849) (xy 155.378412 99.485313) (xy 155.46059 99.639059) - (xy 155.543468 99.740046) (xy 155.543471 99.740049) (xy 155.571184 99.773817) (xy 155.604952 99.80153) (xy 155.938466 100.135044) - (xy 155.966183 100.168817) (xy 156.100941 100.279411) (xy 156.254687 100.361589) (xy 156.42151 100.412195) (xy 156.551523 100.425) - (xy 156.551533 100.425) (xy 156.566374 100.426462) (xy 156.514424 100.478412) (xy 156.220583 100.918175) (xy 156.018183 101.406814) - (xy 155.915 101.925551) (xy 155.915 102.454449) (xy 156.018183 102.973186) (xy 156.023749 102.986623) (xy 155.801302 102.837989) - (xy 155.492012 102.709877) (xy 155.527932 102.623158) (xy 155.585 102.33626) (xy 155.585 102.04374) (xy 155.527932 101.756842) - (xy 155.41599 101.486589) (xy 155.253475 101.243368) (xy 155.046632 101.036525) (xy 154.803411 100.87401) (xy 154.533158 100.762068) - (xy 154.24626 100.705) (xy 154.076697 100.705) (xy 153.982327 100.665911) (xy 153.676109 100.605) (xy 153.363891 100.605) - (xy 153.057673 100.665911) (xy 152.769221 100.785391) (xy 152.509621 100.95885) (xy 152.28885 101.179621) (xy 152.115391 101.439221) - (xy 151.995911 101.727673) (xy 151.935 102.033891) (xy 151.935 102.346109) (xy 151.995911 102.652327) (xy 152.115391 102.940779) - (xy 152.28885 103.200379) (xy 152.509621 103.42115) (xy 152.769221 103.594609) (xy 152.935016 103.663283) (xy 152.897988 103.718699) - (xy 152.737047 104.107245) (xy 152.655 104.519722) (xy 152.655 104.94028) (xy 152.737047 105.352757) (xy 152.869252 105.671928) - (xy 151.75 105.671928) (xy 151.66 105.680792) (xy 151.66 101.277322) (xy 151.663676 101.239999) (xy 151.66 101.202676) - (xy 151.66 101.202667) (xy 151.649003 101.091014) (xy 151.605546 100.947753) (xy 151.534974 100.815724) (xy 151.440001 100.699999) - (xy 151.411003 100.676201) (xy 151.113072 100.37827) (xy 151.113072 99.69) (xy 151.100812 99.565518) (xy 151.064502 99.44582) - (xy 151.005537 99.335506) (xy 150.926185 99.238815) (xy 150.829494 99.159463) (xy 150.71918 99.100498) (xy 150.599482 99.064188) - (xy 150.475 99.051928) (xy 149.525 99.051928) (xy 149.400518 99.064188) (xy 149.28082 99.100498) (xy 149.170506 99.159463) - (xy 149.073815 99.238815) (xy 148.994463 99.335506) (xy 148.935498 99.44582) (xy 148.899188 99.565518) (xy 148.886928 99.69) - (xy 148.886928 100.99) (xy 148.899188 101.114482) (xy 148.935498 101.23418) (xy 148.994463 101.344494) (xy 149.073815 101.441185) - (xy 149.170506 101.520537) (xy 149.28082 101.579502) (xy 149.400518 101.615812) (xy 149.525 101.628072) (xy 150.140001 101.628072) - (xy 150.14 106.192843) (xy 150.097089 106.29644) (xy 150.065 106.45776) (xy 150.065 106.62224) (xy 150.097089 106.78356) - (xy 150.140001 106.887159) (xy 150.14 109.302679) (xy 150.136324 109.340002) (xy 150.14 109.377324) (xy 150.14 109.377334) - (xy 150.150997 109.488987) (xy 150.179297 109.582281) (xy 150.194454 109.632248) (xy 150.265026 109.764278) (xy 150.295009 109.800812) - (xy 150.359999 109.880003) (xy 150.389002 109.903805) (xy 151.061204 110.576009) (xy 151.084998 110.605002) (xy 151.113991 110.628796) - (xy 151.113995 110.6288) (xy 151.175187 110.679018) (xy 151.200723 110.699975) (xy 151.332752 110.770547) (xy 151.476013 110.814004) - (xy 151.587666 110.825001) (xy 151.587675 110.825001) (xy 151.624998 110.828677) (xy 151.662321 110.825001) (xy 164.587677 110.825001) - (xy 164.624999 110.828677) (xy 164.662321 110.825001) (xy 164.662332 110.825001) (xy 164.773985 110.814004) (xy 164.917246 110.770547) - (xy 165.049275 110.699975) (xy 165.165 110.605002) (xy 165.188803 110.575999) (xy 166.111003 109.653799) (xy 166.140001 109.630001) - (xy 166.234974 109.514276) (xy 166.305546 109.382247) (xy 166.349003 109.238986) (xy 166.36 109.127333) (xy 166.36 109.127325) - (xy 166.363676 109.09) (xy 166.36 109.052675) (xy 166.36 106.408072) (xy 166.75 106.408072) (xy 166.874482 106.395812) - (xy 166.99418 106.359502) (xy 167.104494 106.300537) (xy 167.201185 106.221185) (xy 167.280537 106.124494) (xy 167.339502 106.01418) - (xy 167.375812 105.894482) (xy 167.388072 105.77) (xy 167.388072 103.77) (xy 167.375812 103.645518) (xy 167.339502 103.52582) - (xy 167.280537 103.415506) (xy 167.201185 103.318815) (xy 167.104494 103.239463) (xy 166.99418 103.180498) (xy 166.874482 103.144188) - (xy 166.75 103.131928) (xy 164.956887 103.131928) (xy 165.084609 102.940779) (xy 165.204089 102.652327) (xy 165.265 102.346109) - (xy 165.265 102.033891) (xy 165.204089 101.727673) (xy 165.084609 101.439221) (xy 164.91115 101.179621) (xy 164.690379 100.95885) - (xy 164.430779 100.785391) (xy 164.142327 100.665911) (xy 163.836109 100.605) (xy 163.523891 100.605) (xy 163.217673 100.665911) - (xy 163.123303 100.705) (xy 162.95374 100.705) (xy 162.666842 100.762068) (xy 162.396589 100.87401) (xy 162.153368 101.036525) - (xy 161.946525 101.243368) (xy 161.78401 101.486589) (xy 161.672068 101.756842) (xy 161.615 102.04374) (xy 161.615 102.33626) - (xy 161.672068 102.623158) (xy 161.707988 102.709876) (xy 161.398698 102.837988) (xy 161.176252 102.986622) (xy 161.181817 102.973186) - (xy 161.285 102.454449) (xy 161.285 101.925551) (xy 161.181817 101.406814) (xy 160.979417 100.918175) (xy 160.685576 100.478412) - (xy 160.632164 100.425) (xy 165.556511 100.425) (xy 165.59998 100.429281) (xy 165.643449 100.425) (xy 165.643457 100.425) - (xy 165.77347 100.412195) (xy 165.940293 100.361589) (xy 166.094039 100.279411) (xy 166.228797 100.168817) (xy 166.256514 100.135044) - (xy 167.081522 99.310037) (xy 167.1644 99.20905) (xy 167.246578 99.055304) (xy 167.297184 98.888481) (xy 167.314271 98.714991) - (xy 167.297184 98.541501) (xy 167.246578 98.374677) (xy 167.1644 98.220932) (xy 167.053807 98.086173) (xy 166.919048 97.97558) - (xy 166.765303 97.893402) (xy 166.598479 97.842796) (xy 166.424989 97.825709) (xy 166.251499 97.842796) (xy 166.084676 97.893402) - (xy 165.93093 97.97558) (xy 165.829943 98.058458) (xy 165.233402 98.655) (xy 162.042538 98.655) (xy 162.04418 98.654502) - (xy 162.154494 98.595537) (xy 162.251185 98.516185) (xy 162.330537 98.419494) (xy 162.381046 98.325) (xy 162.687678 98.325) - (xy 162.725 98.328676) (xy 162.762322 98.325) (xy 162.762333 98.325) (xy 162.873986 98.314003) (xy 163.017247 98.270546) - (xy 163.149276 98.199974) (xy 163.265001 98.105001) (xy 163.288803 98.075998) (xy 163.811004 97.553798) (xy 163.840001 97.530001) - (xy 163.934974 97.414276) (xy 164.005546 97.282247) (xy 164.049003 97.138986) (xy 164.06 97.027333) (xy 164.06 97.027325) - (xy 164.063676 96.99) (xy 164.06 96.952675) (xy 164.06 96.014134) (xy 164.063676 95.976812) (xy 164.06 95.939489) - (xy 164.06 95.939479) (xy 164.049003 95.827826) (xy 164.005546 95.684565) (xy 163.987725 95.651224) (xy 163.934974 95.552535) - (xy 163.863799 95.465809) (xy 163.840001 95.436811) (xy 163.811003 95.413013) (xy 162.576992 94.179003) (xy 162.553189 94.149999) - (xy 162.437464 94.055026) (xy 162.305435 93.984454) (xy 162.162174 93.940997) (xy 162.050521 93.93) (xy 162.05051 93.93) - (xy 162.013188 93.926324) (xy 161.975866 93.93) (xy 161.797157 93.93) (xy 161.69356 93.887089) (xy 161.53224 93.855) - (xy 161.36776 93.855) (xy 161.20644 93.887089) (xy 161.054479 93.950033) (xy 160.937873 94.027946) (xy 160.854475 93.926325) - (xy 160.746363 93.8376) (xy 160.62302 93.771672) (xy 160.489184 93.731073) (xy 160.384877 93.7208) (xy 160.35 93.717365) - (xy 160.315123 93.7208) (xy 156.96 93.7208) (xy 156.96 93.652302) (xy 156.963676 93.614979) (xy 156.96 93.577656) - (xy 156.96 93.577646) (xy 156.949003 93.465993) (xy 156.905546 93.322732) (xy 156.834974 93.190703) (xy 156.740001 93.074978) - (xy 156.711002 93.05118) (xy 156.7098 93.049977) (xy 163.935176 93.049977) (xy 165.5462 94.661002) (xy 165.57 94.690002) - (xy 165.685725 94.784975) (xy 165.817754 94.855547) (xy 165.961015 94.899004) (xy 166.072668 94.910001) (xy 166.072677 94.910001) - (xy 166.11 94.913677) (xy 166.147323 94.910001) (xy 168.490001 94.910001) (xy 168.49 98.552843) (xy 168.447089 98.65644) - (xy 168.415 98.81776) (xy 168.415 98.98224) (xy 168.447089 99.14356) (xy 168.459533 99.173602) (xy 168.420506 99.194463) - (xy 168.323815 99.273815) (xy 168.244463 99.370506) (xy 168.185498 99.48082) (xy 168.149188 99.600518) (xy 168.136928 99.725) - (xy 168.136928 101.025) (xy 168.149188 101.149482) (xy 168.185498 101.26918) (xy 168.244463 101.379494) (xy 168.323815 101.476185) - (xy 168.420506 101.555537) (xy 168.53082 101.614502) (xy 168.650518 101.650812) (xy 168.775 101.663072) (xy 169.725 101.663072) - (xy 169.849482 101.650812) (xy 169.96918 101.614502) (xy 170.079494 101.555537) (xy 170.176185 101.476185) (xy 170.255537 101.379494) - (xy 170.314502 101.26918) (xy 170.350812 101.149482) (xy 170.363072 101.025) (xy 170.363072 99.725) (xy 170.350812 99.600518) - (xy 170.314502 99.48082) (xy 170.255537 99.370506) (xy 170.176185 99.273815) (xy 170.079494 99.194463) (xy 170.040467 99.173602) - (xy 170.052911 99.14356) (xy 170.085 98.98224) (xy 170.085 98.81776) (xy 170.052911 98.65644) (xy 170.01 98.552843) - (xy 170.01 95.51) (xy 170.08224 95.51) (xy 170.24356 95.477911) (xy 170.395521 95.414967) (xy 170.402955 95.41) - (xy 181.185199 95.41) (xy 182.649602 96.874404) (xy 182.6734 96.903402) (xy 182.702398 96.9272) (xy 182.789124 96.998375) - (xy 182.857706 97.035033) (xy 182.921154 97.068947) (xy 183.064415 97.112404) (xy 183.176068 97.123401) (xy 183.176078 97.123401) - (xy 183.213401 97.127077) (xy 183.250724 97.123401) (xy 185.127842 97.123401) (xy 185.231439 97.166312) (xy 185.392759 97.198401) - (xy 185.557239 97.198401) (xy 185.718559 97.166312) (xy 185.87052 97.103368) (xy 186.00728 97.011988) (xy 186.123586 96.895682) - (xy 186.214966 96.758922) (xy 186.27791 96.606961) (xy 186.309999 96.445641) (xy 186.309999 96.281161) (xy 186.27791 96.119841) - (xy 186.214966 95.96788) (xy 186.123586 95.83112) (xy 186.00728 95.714814) (xy 185.87052 95.623434) (xy 185.718559 95.56049) - (xy 185.557239 95.528401) (xy 185.392759 95.528401) (xy 185.231439 95.56049) (xy 185.127842 95.603401) (xy 183.528203 95.603401) - (xy 183.061957 95.137155) (xy 183.101014 95.149003) (xy 183.212667 95.16) (xy 183.212676 95.16) (xy 183.249999 95.163676) - (xy 183.287322 95.16) (xy 185.652843 95.16) (xy 185.75644 95.202911) (xy 185.91776 95.235) (xy 186.08224 95.235) - (xy 186.24356 95.202911) (xy 186.395521 95.139967) (xy 186.532281 95.048587) (xy 186.648587 94.932281) (xy 186.739967 94.795521) - (xy 186.802911 94.64356) (xy 186.835 94.48224) (xy 186.835 94.31776) (xy 186.802911 94.15644) (xy 186.739967 94.004479) - (xy 186.648587 93.867719) (xy 186.532281 93.751413) (xy 186.395521 93.660033) (xy 186.24356 93.597089) (xy 186.08224 93.565) - (xy 185.91776 93.565) (xy 185.75644 93.597089) (xy 185.652843 93.64) (xy 184.534801 93.64) (xy 185.111003 93.063799) - (xy 185.140001 93.040001) (xy 185.234974 92.924276) (xy 185.305546 92.792247) (xy 185.349003 92.648986) (xy 185.36 92.537333) - (xy 185.36 92.537325) (xy 185.363676 92.5) (xy 185.36 92.462675) (xy 185.36 89.9) (xy 187.386928 89.9) - (xy 187.386928 91.2) (xy 187.399188 91.324482) (xy 187.435498 91.44418) (xy 187.494463 91.554494) (xy 187.573815 91.651185) - (xy 187.665 91.726018) (xy 187.665 91.83224) (xy 187.697089 91.99356) (xy 187.760033 92.145521) (xy 187.851413 92.282281) - (xy 187.967719 92.398587) (xy 188.104479 92.489967) (xy 188.25644 92.552911) (xy 188.41776 92.585) (xy 188.58224 92.585) - (xy 188.74356 92.552911) (xy 188.895521 92.489967) (xy 189.032281 92.398587) (xy 189.148587 92.282281) (xy 189.239967 92.145521) - (xy 189.302911 91.99356) (xy 189.335 91.83224) (xy 189.335 91.726018) (xy 189.426185 91.651185) (xy 189.505537 91.554494) - (xy 189.564502 91.44418) (xy 189.600812 91.324482) (xy 189.613072 91.2) (xy 189.613072 89.9) (xy 189.600812 89.775518) - (xy 189.564502 89.65582) (xy 189.505537 89.545506) (xy 189.426185 89.448815) (xy 189.329494 89.369463) (xy 189.21918 89.310498) - (xy 189.099482 89.274188) (xy 188.975 89.261928) (xy 188.025 89.261928) (xy 187.900518 89.274188) (xy 187.78082 89.310498) - (xy 187.670506 89.369463) (xy 187.573815 89.448815) (xy 187.494463 89.545506) (xy 187.435498 89.65582) (xy 187.399188 89.775518) - (xy 187.386928 89.9) (xy 185.36 89.9) (xy 185.36 89.818072) (xy 185.75 89.818072) (xy 185.874482 89.805812) - (xy 185.99418 89.769502) (xy 186.104494 89.710537) (xy 186.201185 89.631185) (xy 186.280537 89.534494) (xy 186.339502 89.42418) - (xy 186.375812 89.304482) (xy 186.388072 89.18) (xy 186.388072 87.18) (xy 186.375812 87.055518) (xy 186.339502 86.93582) - (xy 186.280537 86.825506) (xy 186.201185 86.728815) (xy 186.104494 86.649463) (xy 185.99418 86.590498) (xy 185.874482 86.554188) - (xy 185.75 86.541928) (xy 183.956887 86.541928) (xy 184.084609 86.350779) (xy 184.204089 86.062327) (xy 184.265 85.756109) - (xy 184.265 85.443891) (xy 184.204089 85.137673) (xy 184.084609 84.849221) (xy 183.91115 84.589621) (xy 183.690379 84.36885) - (xy 183.430779 84.195391) (xy 183.142327 84.075911) (xy 182.836109 84.015) (xy 182.523891 84.015) (xy 182.217673 84.075911) - (xy 182.123303 84.115) (xy 181.95374 84.115) (xy 181.666842 84.172068) (xy 181.396589 84.28401) (xy 181.153368 84.446525) - (xy 180.946525 84.653368) (xy 180.78401 84.896589) (xy 180.672068 85.166842) (xy 180.615 85.45374) (xy 180.615 85.74626) - (xy 180.672068 86.033158) (xy 180.707988 86.119876) (xy 180.398698 86.247988) (xy 180.176252 86.396622) (xy 180.181817 86.383186) - (xy 180.285 85.864449) (xy 180.285 85.335551) (xy 180.181817 84.816814) (xy 179.979417 84.328175) (xy 179.685576 83.888412) - (xy 179.457164 83.66) (xy 183.789324 83.66) (xy 183.90644 83.708511) (xy 184.06776 83.7406) (xy 184.23224 83.7406) - (xy 184.39356 83.708511) (xy 184.545521 83.645567) (xy 184.682281 83.554187) (xy 184.798587 83.437881) (xy 184.889967 83.301121) - (xy 184.952911 83.14916) (xy 184.985 82.98784) (xy 184.985 82.82336) (xy 185.1946 82.82336) (xy 185.1946 82.98784) - (xy 185.226689 83.14916) (xy 185.289633 83.301121) (xy 185.381013 83.437881) (xy 185.497319 83.554187) (xy 185.634079 83.645567) - (xy 185.737678 83.688479) (xy 187.74 85.690802) (xy 187.74 85.782317) (xy 187.670506 85.819463) (xy 187.573815 85.898815) - (xy 187.494463 85.995506) (xy 187.435498 86.10582) (xy 187.399188 86.225518) (xy 187.386928 86.35) (xy 187.386928 87.65) - (xy 187.399188 87.774482) (xy 187.435498 87.89418) (xy 187.494463 88.004494) (xy 187.573815 88.101185) (xy 187.665 88.176018) - (xy 187.665 88.33224) (xy 187.697089 88.49356) (xy 187.760033 88.645521) (xy 187.851413 88.782281) (xy 187.967719 88.898587) - (xy 188.104479 88.989967) (xy 188.25644 89.052911) (xy 188.41776 89.085) (xy 188.58224 89.085) (xy 188.74356 89.052911) - (xy 188.895521 88.989967) (xy 189.032281 88.898587) (xy 189.148587 88.782281) (xy 189.239967 88.645521) (xy 189.302911 88.49356) - (xy 189.335 88.33224) (xy 189.335 88.176018) (xy 189.426185 88.101185) (xy 189.505537 88.004494) (xy 189.564502 87.89418) - (xy 189.600812 87.774482) (xy 189.613072 87.65) (xy 189.613072 86.35) (xy 189.600812 86.225518) (xy 189.564502 86.10582) - (xy 189.505537 85.995506) (xy 189.426185 85.898815) (xy 189.329494 85.819463) (xy 189.26 85.782317) (xy 189.26 85.413322) - (xy 189.263676 85.375999) (xy 189.26 85.338676) (xy 189.26 85.338667) (xy 189.249003 85.227014) (xy 189.205546 85.083753) - (xy 189.134974 84.951724) (xy 189.040001 84.835999) (xy 189.011004 84.812202) (xy 186.812479 82.613678) (xy 186.769567 82.510079) - (xy 186.678187 82.373319) (xy 186.561881 82.257013) (xy 186.425121 82.165633) (xy 186.27316 82.102689) (xy 186.11184 82.0706) - (xy 185.94736 82.0706) (xy 185.78604 82.102689) (xy 185.634079 82.165633) (xy 185.497319 82.257013) (xy 185.381013 82.373319) - (xy 185.289633 82.510079) (xy 185.226689 82.66204) (xy 185.1946 82.82336) (xy 184.985 82.82336) (xy 184.952911 82.66204) - (xy 184.889967 82.510079) (xy 184.798587 82.373319) (xy 184.682281 82.257013) (xy 184.545521 82.165633) (xy 184.39356 82.102689) - (xy 184.23224 82.0706) (xy 184.06776 82.0706) (xy 183.90644 82.102689) (xy 183.816363 82.14) (xy 180.06 82.14) - (xy 180.06 82.113072) (xy 180.8 82.113072) (xy 180.924482 82.100812) (xy 181.04418 82.064502) (xy 181.154494 82.005537) - (xy 181.251185 81.926185) (xy 181.330537 81.829494) (xy 181.389502 81.71918) (xy 181.425812 81.599482) (xy 181.431418 81.542562) - (xy 181.465001 81.515001) (xy 181.488803 81.485998) (xy 181.891923 81.082878) (xy 181.995521 81.039967) (xy 182.132281 80.948587) - (xy 182.248587 80.832281) (xy 182.339967 80.695521) (xy 182.402911 80.54356) (xy 182.435 80.38224) (xy 182.435 80.21776) - (xy 182.402911 80.05644) (xy 182.339967 79.904479) (xy 182.248587 79.767719) (xy 182.132281 79.651413) (xy 181.995521 79.560033) - (xy 181.84356 79.497089) (xy 181.68224 79.465) (xy 181.51776 79.465) (xy 181.410571 79.486321) (xy 181.27625 79.352) - (xy 180.127 79.352) (xy 180.127 79.372) (xy 180.06 79.372) (xy 180.06 79.078) (xy 180.127 79.078) - (xy 180.127 79.098) (xy 181.27625 79.098) (xy 181.435 78.93925) (xy 181.438072 78.725) (xy 181.425812 78.600518) - (xy 181.389502 78.48082) (xy 181.330537 78.370506) (xy 181.251185 78.273815) (xy 181.154494 78.194463) (xy 181.04418 78.135498) - (xy 180.924482 78.099188) (xy 180.8 78.086928) (xy 180.28575 78.09) (xy 180.127002 78.248748) (xy 180.127002 78.09) - (xy 180.06 78.09) (xy 180.06 77.984877) (xy 180.063435 77.95) (xy 180.049727 77.810816) (xy 180.009128 77.67698) - (xy 179.9432 77.553637) (xy 179.854475 77.445525) (xy 179.746363 77.3568) (xy 179.62302 77.290872) (xy 179.489184 77.250273) - (xy 179.384877 77.24) (xy 179.35 77.236565) (xy 179.315123 77.24) (xy 175.884877 77.24) (xy 175.85 77.236565) - (xy 175.815123 77.24) (xy 175.710816 77.250273) (xy 175.57698 77.290872) (xy 175.453637 77.3568) (xy 175.345525 77.445525) - (xy 175.2568 77.553637) (xy 175.190872 77.67698) (xy 175.150273 77.810816) (xy 175.136565 77.95) (xy 175.140001 77.984887) - (xy 175.140001 78.086928) (xy 174.4 78.086928) (xy 174.275518 78.099188) (xy 174.15582 78.135498) (xy 174.045506 78.194463) - (xy 173.948815 78.273815) (xy 173.869463 78.370506) (xy 173.810498 78.48082) (xy 173.806686 78.493387) (xy 173.720753 78.519454) - (xy 173.588724 78.590026) (xy 173.472999 78.684999) (xy 173.4492 78.713998) (xy 172.989002 79.174197) (xy 172.959999 79.197999) - (xy 172.916164 79.251413) (xy 172.865026 79.313724) (xy 172.80849 79.419494) (xy 172.794454 79.445754) (xy 172.750997 79.589015) - (xy 172.74 79.700668) (xy 172.74 79.700678) (xy 172.736324 79.738) (xy 172.74 79.775322) (xy 172.74 80.002841) - (xy 172.697089 80.106438) (xy 172.665 80.267758) (xy 172.665 80.432238) (xy 172.673412 80.474526) (xy 172.605941 80.510589) - (xy 172.471183 80.621183) (xy 172.360589 80.755941) (xy 172.278411 80.909687) (xy 172.269919 80.937681) (xy 172.148986 80.900997) - (xy 172.037333 80.89) (xy 172.037322 80.89) (xy 172 80.886324) (xy 171.962678 80.89) (xy 170.827238 80.89) - (xy 170.825812 80.875518) (xy 170.789502 80.75582) (xy 170.730537 80.645506) (xy 170.651185 80.548815) (xy 170.554494 80.469463) - (xy 170.44418 80.410498) (xy 170.324482 80.374188) (xy 170.2 80.361928) (xy 169.25 80.361928) (xy 169.125518 80.374188) - (xy 169.00582 80.410498) (xy 168.895506 80.469463) (xy 168.798815 80.548815) (xy 168.719463 80.645506) (xy 168.660498 80.75582) - (xy 168.624188 80.875518) (xy 168.611928 81) (xy 168.611928 82.3) (xy 168.624188 82.424482) (xy 168.660498 82.54418) - (xy 168.719463 82.654494) (xy 168.798815 82.751185) (xy 168.895506 82.830537) (xy 169.00582 82.889502) (xy 169.125518 82.925812) - (xy 169.25 82.938072) (xy 170.2 82.938072) (xy 170.324482 82.925812) (xy 170.44418 82.889502) (xy 170.554494 82.830537) - (xy 170.651185 82.751185) (xy 170.730537 82.654494) (xy 170.789502 82.54418) (xy 170.825812 82.424482) (xy 170.827238 82.41) - (xy 171.685199 82.41) (xy 172.6862 83.411002) (xy 172.709999 83.440001) (xy 172.738997 83.463799) (xy 172.825723 83.534974) - (xy 172.914151 83.58224) (xy 172.957753 83.605546) (xy 173.101014 83.649003) (xy 173.212667 83.66) (xy 173.212677 83.66) - (xy 173.25 83.663676) (xy 173.287323 83.66) (xy 174.445386 83.66) (xy 174.447089 83.66856) (xy 174.510033 83.820521) - (xy 174.601413 83.957281) (xy 174.717719 84.073587) (xy 174.854479 84.164967) (xy 175.00644 84.227911) (xy 175.16776 84.26) - (xy 175.266136 84.26) (xy 175.220583 84.328175) (xy 175.018183 84.816814) (xy 174.915 85.335551) (xy 174.915 85.864449) - (xy 175.018183 86.383186) (xy 175.023749 86.396623) (xy 174.801302 86.247989) (xy 174.492012 86.119877) (xy 174.527932 86.033158) - (xy 174.585 85.74626) (xy 174.585 85.45374) (xy 174.527932 85.166842) (xy 174.41599 84.896589) (xy 174.253475 84.653368) - (xy 174.046632 84.446525) (xy 173.803411 84.28401) (xy 173.533158 84.172068) (xy 173.24626 84.115) (xy 173.076697 84.115) - (xy 172.982327 84.075911) (xy 172.676109 84.015) (xy 172.363891 84.015) (xy 172.057673 84.075911) (xy 171.769221 84.195391) - (xy 171.509621 84.36885) (xy 171.28885 84.589621) (xy 171.115391 84.849221) (xy 170.995911 85.137673) (xy 170.935 85.443891) - (xy 170.935 85.756109) (xy 170.995911 86.062327) (xy 171.115391 86.350779) (xy 171.28885 86.610379) (xy 171.509621 86.83115) - (xy 171.769221 87.004609) (xy 171.935016 87.073283) (xy 171.897988 87.128699) (xy 171.737047 87.517245) (xy 171.655 87.929722) - (xy 171.655 88.35028) (xy 171.737047 88.762757) (xy 171.869252 89.081928) (xy 170.75 89.081928) (xy 170.625518 89.094188) - (xy 170.50582 89.130498) (xy 170.395506 89.189463) (xy 170.336818 89.237627) (xy 170.295521 89.210033) (xy 170.14356 89.147089) - (xy 169.98224 89.115) (xy 169.81776 89.115) (xy 169.65644 89.147089) (xy 169.504479 89.210033) (xy 169.367719 89.301413) - (xy 169.251413 89.417719) (xy 169.160033 89.554479) (xy 169.097089 89.70644) (xy 169.065 89.86776) (xy 169.065 90.03224) - (xy 169.097089 90.19356) (xy 169.140001 90.297159) (xy 169.14 92.712679) (xy 169.136324 92.750002) (xy 169.14 92.787324) - (xy 169.14 92.787334) (xy 169.149912 92.887967) (xy 169.145521 92.885033) (xy 168.99356 92.822089) (xy 168.83224 92.79) - (xy 168.66776 92.79) (xy 168.50644 92.822089) (xy 168.402843 92.865) (xy 166.599802 92.865) (xy 165.249801 91.515) - (xy 166.011003 90.753799) (xy 166.040001 90.730001) (xy 166.134974 90.614276) (xy 166.205546 90.482247) (xy 166.249003 90.338986) - (xy 166.26 90.227333) (xy 166.26 90.227325) (xy 166.263676 90.19) (xy 166.26 90.152675) (xy 166.26 87.408072) - (xy 166.440001 87.408072) (xy 166.440001 91.758477) (xy 166.452806 91.88849) (xy 166.503412 92.055313) (xy 166.58559 92.209059) - (xy 166.696184 92.343817) (xy 166.830942 92.454411) (xy 166.984688 92.536589) (xy 167.151511 92.587195) (xy 167.325 92.604282) - (xy 167.49849 92.587195) (xy 167.665313 92.536589) (xy 167.819059 92.454411) (xy 167.953817 92.343817) (xy 168.064411 92.209059) - (xy 168.146589 92.055313) (xy 168.197195 91.88849) (xy 168.21 91.758477) (xy 168.21 84.55) (xy 168.611928 84.55) - (xy 168.611928 85.85) (xy 168.624188 85.974482) (xy 168.660498 86.09418) (xy 168.719463 86.204494) (xy 168.798815 86.301185) - (xy 168.895506 86.380537) (xy 168.946789 86.407949) (xy 168.915 86.56776) (xy 168.915 86.73224) (xy 168.947089 86.89356) - (xy 169.010033 87.045521) (xy 169.101413 87.182281) (xy 169.217719 87.298587) (xy 169.354479 87.389967) (xy 169.50644 87.452911) - (xy 169.66776 87.485) (xy 169.83224 87.485) (xy 169.99356 87.452911) (xy 170.145521 87.389967) (xy 170.282281 87.298587) - (xy 170.398587 87.182281) (xy 170.489967 87.045521) (xy 170.552911 86.89356) (xy 170.585 86.73224) (xy 170.585 86.56776) - (xy 170.552911 86.40644) (xy 170.544414 86.385925) (xy 170.554494 86.380537) (xy 170.651185 86.301185) (xy 170.730537 86.204494) - (xy 170.789502 86.09418) (xy 170.825812 85.974482) (xy 170.838072 85.85) (xy 170.838072 84.55) (xy 170.825812 84.425518) - (xy 170.789502 84.30582) (xy 170.730537 84.195506) (xy 170.651185 84.098815) (xy 170.554494 84.019463) (xy 170.44418 83.960498) - (xy 170.324482 83.924188) (xy 170.2 83.911928) (xy 169.25 83.911928) (xy 169.125518 83.924188) (xy 169.00582 83.960498) - (xy 168.895506 84.019463) (xy 168.798815 84.098815) (xy 168.719463 84.195506) (xy 168.660498 84.30582) (xy 168.624188 84.425518) - (xy 168.611928 84.55) (xy 168.21 84.55) (xy 168.21 78.158466) (xy 168.214281 78.114999) (xy 168.21 78.071533) - (xy 168.21 78.071523) (xy 168.197195 77.94151) (xy 168.146589 77.774687) (xy 168.135 77.753005) (xy 168.135 65.463078) - (xy 168.386928 65.21115) (xy 168.386928 66.075) (xy 168.399188 66.199482) (xy 168.435498 66.31918) (xy 168.494463 66.429494) - (xy 168.573815 66.526185) (xy 168.670506 66.605537) (xy 168.78082 66.664502) (xy 168.900518 66.700812) (xy 169.025 66.713072) - (xy 169.708204 66.713072) (xy 169.747533 66.808021) (xy 169.838913 66.944781) (xy 169.955219 67.061087) (xy 170.091979 67.152467) - (xy 170.24394 67.215411) (xy 170.40526 67.2475) (xy 170.56974 67.2475) (xy 170.73106 67.215411) (xy 170.883021 67.152467) - (xy 171.019781 67.061087) (xy 171.031828 67.04904) (xy 171.115391 67.250779) (xy 171.28885 67.510379) (xy 171.509621 67.73115) - (xy 171.769221 67.904609) (xy 171.935016 67.973283) (xy 171.897988 68.028699) (xy 171.737047 68.417245) (xy 171.655 68.829722) - (xy 171.655 69.25028) (xy 171.737047 69.662757) (xy 171.869252 69.981928) (xy 170.75 69.981928) (xy 170.625518 69.994188) - (xy 170.50582 70.030498) (xy 170.395506 70.089463) (xy 170.336818 70.137627) (xy 170.295521 70.110033) (xy 170.14356 70.047089) - (xy 169.98224 70.015) (xy 169.81776 70.015) (xy 169.65644 70.047089) (xy 169.504479 70.110033) (xy 169.367719 70.201413) - (xy 169.251413 70.317719) (xy 169.160033 70.454479) (xy 169.097089 70.60644) (xy 169.065 70.76776) (xy 169.065 70.93224) - (xy 169.097089 71.09356) (xy 169.140001 71.197159) (xy 169.14 73.612679) (xy 169.136324 73.650002) (xy 169.14 73.687324) - (xy 169.14 73.687334) (xy 169.150997 73.798987) (xy 169.182907 73.904181) (xy 169.194454 73.942248) (xy 169.265026 74.074278) - (xy 169.297792 74.114203) (xy 169.359999 74.190003) (xy 169.389002 74.213805) (xy 170.061204 74.886009) (xy 170.084998 74.915002) - (xy 170.113991 74.938796) (xy 170.113995 74.9388) (xy 170.170259 74.984974) (xy 170.200723 75.009975) (xy 170.332752 75.080547) - (xy 170.476013 75.124004) (xy 170.587666 75.135001) (xy 170.587675 75.135001) (xy 170.624998 75.138677) (xy 170.662321 75.135001) - (xy 183.587677 75.135001) (xy 183.624999 75.138677) (xy 183.662321 75.135001) (xy 183.662332 75.135001) (xy 183.773985 75.124004) - (xy 183.917246 75.080547) (xy 184.049275 75.009975) (xy 184.165 74.915002) (xy 184.188803 74.885999) (xy 185.111003 73.963799) - (xy 185.140001 73.940001) (xy 185.234974 73.824276) (xy 185.305546 73.692247) (xy 185.349003 73.548986) (xy 185.36 73.437333) - (xy 185.36 73.437325) (xy 185.363676 73.4) (xy 185.36 73.362675) (xy 185.36 70.718072) (xy 185.75 70.718072) - (xy 185.874482 70.705812) (xy 185.99418 70.669502) (xy 186.104494 70.610537) (xy 186.201185 70.531185) (xy 186.280537 70.434494) - (xy 186.339502 70.32418) (xy 186.375812 70.204482) (xy 186.388072 70.08) (xy 186.388072 68.08) (xy 186.375812 67.955518) - (xy 186.339502 67.83582) (xy 186.280537 67.725506) (xy 186.201185 67.628815) (xy 186.104494 67.549463) (xy 185.99418 67.490498) - (xy 185.874482 67.454188) (xy 185.75 67.441928) (xy 183.956887 67.441928) (xy 184.084609 67.250779) (xy 184.204089 66.962327) - (xy 184.265 66.656109) (xy 184.265 66.343891) (xy 184.204089 66.037673) (xy 184.084609 65.749221) (xy 183.91115 65.489621) - (xy 183.876199 65.45467) (xy 183.898587 65.432281) (xy 183.989967 65.295521) (xy 184.052911 65.14356) (xy 184.085 64.98224) - (xy 184.085 64.81776) (xy 184.052911 64.65644) (xy 183.989967 64.504479) (xy 183.898587 64.367719) (xy 183.782281 64.251413) - (xy 183.710011 64.203124) (xy 183.710011 61.47883) (xy 183.752922 61.375233) (xy 183.785011 61.213913) (xy 183.785011 61.049433) - (xy 183.752922 60.888113) (xy 183.689978 60.736152) (xy 183.598598 60.599392) (xy 183.482292 60.483086) (xy 183.345532 60.391706) - (xy 183.193571 60.328762) (xy 183.032251 60.296673) (xy 182.867771 60.296673) (xy 182.706451 60.328762) (xy 182.55449 60.391706) - (xy 182.41773 60.483086) (xy 182.301424 60.599392) (xy 182.260586 60.66051) (xy 182.198585 60.567719) (xy 182.082279 60.451413) - (xy 181.945519 60.360033) (xy 181.793558 60.297089) (xy 181.632238 60.265) (xy 181.467758 60.265) (xy 181.318867 60.294617) - (xy 181.27625 60.252) (xy 180.127 60.252) (xy 180.127 60.272) (xy 180.06 60.272) (xy 180.06 59.978) - (xy 180.127 59.978) (xy 180.127 59.998) (xy 181.27625 59.998) (xy 181.435 59.83925) (xy 181.438072 59.625) - (xy 181.425812 59.500518) (xy 181.389502 59.38082) (xy 181.330537 59.270506) (xy 181.251185 59.173815) (xy 181.154494 59.094463) - (xy 181.04418 59.035498) (xy 180.924482 58.999188) (xy 180.8 58.986928) (xy 180.28575 58.99) (xy 180.127002 59.148748) - (xy 180.127002 58.99) (xy 180.06 58.99) (xy 180.06 58.783277) (xy 180.063435 58.7484) (xy 180.049727 58.609216) - (xy 180.009128 58.47538) (xy 179.9432 58.352037) (xy 179.854475 58.243925) (xy 179.746363 58.1552) (xy 179.62302 58.089272) - (xy 179.489184 58.048673) (xy 179.384877 58.0384) (xy 179.35 58.034965) (xy 179.315123 58.0384) (xy 175.884877 58.0384) - (xy 175.85 58.034965) (xy 175.815123 58.0384) (xy 175.710816 58.048673) (xy 175.57698 58.089272) (xy 175.453637 58.1552) - (xy 175.345525 58.243925) (xy 175.2568 58.352037) (xy 175.190872 58.47538) (xy 175.150273 58.609216) (xy 175.136565 58.7484) - (xy 175.140001 58.783287) (xy 175.140001 58.986928) (xy 174.4 58.986928) (xy 174.275518 58.999188) (xy 174.15582 59.035498) - (xy 174.045506 59.094463) (xy 173.948815 59.173815) (xy 173.869463 59.270506) (xy 173.810498 59.38082) (xy 173.774188 59.500518) - (xy 173.761928 59.625) (xy 173.761928 59.91327) (xy 173.322722 60.352476) (xy 173.304479 60.360033) (xy 173.167719 60.451413) - (xy 173.051413 60.567719) (xy 172.960033 60.704479) (xy 172.897089 60.85644) (xy 172.870522 60.99) (xy 172.310001 60.99) - (xy 172.310001 60.47047) (xy 172.314282 60.427001) (xy 172.310001 60.383532) (xy 172.310001 60.383524) (xy 172.297196 60.253511) - (xy 172.24659 60.086688) (xy 172.164412 59.932942) (xy 172.122145 59.88144) (xy 172.081533 59.831954) (xy 172.081531 59.831952) - (xy 172.053818 59.798184) (xy 172.020051 59.770472) (xy 168.635 56.385422) (xy 168.635 53.833477) (xy 168.639282 53.79) - (xy 168.635 53.746523) (xy 168.635 48.471105) (xy 168.650518 48.475812) (xy 168.775 48.488072) (xy 169.725 48.488072) - (xy 169.849482 48.475812) (xy 169.934399 48.450053) (xy 169.934399 51.015) (xy 169.81776 51.015) (xy 169.65644 51.047089) - (xy 169.504479 51.110033) (xy 169.367719 51.201413) (xy 169.251413 51.317719) (xy 169.160033 51.454479) (xy 169.097089 51.60644) - (xy 169.065 51.76776) (xy 169.065 51.93224) (xy 169.097089 52.09356) (xy 169.140001 52.197159) (xy 169.14 54.612679) - (xy 169.136324 54.650002) (xy 169.14 54.687324) (xy 169.14 54.687334) (xy 169.150997 54.798987) (xy 169.184976 54.911003) - (xy 169.194454 54.942248) (xy 169.265026 55.074278) (xy 169.304871 55.122828) (xy 169.359999 55.190003) (xy 169.389002 55.213805) - (xy 170.061204 55.886009) (xy 170.084998 55.915002) (xy 170.113991 55.938796) (xy 170.113995 55.9388) (xy 170.175729 55.989463) - (xy 170.200723 56.009975) (xy 170.332752 56.080547) (xy 170.476013 56.124004) (xy 170.587666 56.135001) (xy 170.587675 56.135001) - (xy 170.624998 56.138677) (xy 170.662321 56.135001) (xy 183.587677 56.135001) (xy 183.624999 56.138677) (xy 183.662321 56.135001) - (xy 183.662332 56.135001) (xy 183.773985 56.124004) (xy 183.917246 56.080547) (xy 184.049275 56.009975) (xy 184.165 55.915002) - (xy 184.188803 55.885999) (xy 185.111004 54.963798) (xy 185.140001 54.940001) (xy 185.234974 54.824276) (xy 185.305546 54.692247) - (xy 185.349003 54.548986) (xy 185.36 54.437333) (xy 185.36 54.437325) (xy 185.363676 54.4) (xy 185.36 54.362675) - (xy 185.36 51.718072) (xy 185.75 51.718072) (xy 185.874482 51.705812) (xy 185.99418 51.669502) (xy 186.104494 51.610537) - (xy 186.201185 51.531185) (xy 186.280537 51.434494) (xy 186.339502 51.32418) (xy 186.375812 51.204482) (xy 186.388072 51.08) - (xy 186.388072 49.08) (xy 186.375812 48.955518) (xy 186.339502 48.83582) (xy 186.280537 48.725506) (xy 186.201185 48.628815) - (xy 186.104494 48.549463) (xy 185.99418 48.490498) (xy 185.874482 48.454188) (xy 185.75 48.441928) (xy 183.956887 48.441928) - (xy 184.084609 48.250779) (xy 184.204089 47.962327) (xy 184.265 47.656109) (xy 184.265 47.343891) (xy 184.204089 47.037673) - (xy 184.084609 46.749221) (xy 183.91115 46.489621) (xy 183.690379 46.26885) (xy 183.430779 46.095391) (xy 183.142327 45.975911) - (xy 182.836109 45.915) (xy 182.523891 45.915) (xy 182.217673 45.975911) (xy 182.123303 46.015) (xy 181.95374 46.015) - (xy 181.666842 46.072068) (xy 181.396589 46.18401) (xy 181.153368 46.346525) (xy 180.946525 46.553368) (xy 180.78401 46.796589) - (xy 180.672068 47.066842) (xy 180.615 47.35374) (xy 180.615 47.64626) (xy 180.672068 47.933158) (xy 180.707988 48.019876) - (xy 180.398698 48.147988) (xy 180.176252 48.296622) (xy 180.181817 48.283186) (xy 180.285 47.764449) (xy 180.285 47.235551) - (xy 180.181817 46.716814) (xy 179.979417 46.228175) (xy 179.685576 45.788412) (xy 179.657164 45.76) (xy 179.812677 45.76) - (xy 179.849999 45.763676) (xy 179.887321 45.76) (xy 179.887332 45.76) (xy 179.998985 45.749003) (xy 180.142246 45.705546) - (xy 180.274275 45.634974) (xy 180.39 45.540001) (xy 180.413803 45.510997) (xy 180.541922 45.382878) (xy 180.645521 45.339966) - (xy 180.782281 45.248586) (xy 180.898587 45.13228) (xy 180.989967 44.99552) (xy 181.052911 44.843559) (xy 181.085 44.682239) - (xy 181.085 44.517759) (xy 181.052911 44.356439) (xy 181.01 44.252842) (xy 181.01 43.97487) (xy 181.04418 43.964502) - (xy 181.154494 43.905537) (xy 181.251185 43.826185) (xy 181.330537 43.729494) (xy 181.389502 43.61918) (xy 181.425812 43.499482) - (xy 181.438072 43.375) (xy 181.438072 42.375) (xy 181.425812 42.250518) (xy 181.389502 42.13082) (xy 181.330537 42.020506) - (xy 181.313708 42) (xy 181.330537 41.979494) (xy 181.389502 41.86918) (xy 181.425812 41.749482) (xy 181.438072 41.625) - (xy 181.435 41.41075) (xy 181.27625 41.252) (xy 180.127 41.252) (xy 180.127 41.272) (xy 180.06 41.272) - (xy 180.06 40.978) (xy 180.127 40.978) (xy 180.127 40.998) (xy 181.27625 40.998) (xy 181.435 40.83925) - (xy 181.436495 40.735) (xy 181.58224 40.735) (xy 181.74356 40.702911) (xy 181.895521 40.639967) (xy 182.032281 40.548587) - (xy 182.148587 40.432281) (xy 182.239967 40.295521) (xy 182.302911 40.14356) (xy 182.335 39.98224) (xy 182.335 39.81776) - (xy 182.302911 39.65644) (xy 182.239967 39.504479) (xy 182.148587 39.367719) (xy 182.032281 39.251413) (xy 181.895521 39.160033) - (xy 181.791922 39.117121) (xy 181.634801 38.96) (xy 188.535199 38.96) + (xy 134.789809 118.05617) (xy 134.778583 118.065383) (xy 134.66799 118.200141) (xy 134.585812 118.353887) (xy 134.535205 118.52071) + (xy 134.518119 118.6942) (xy 134.535205 118.86769) (xy 134.585812 119.034513) (xy 134.66799 119.188259) (xy 134.750868 119.289246) + (xy 135.131666 119.670044) (xy 135.159383 119.703817) (xy 135.294141 119.814411) (xy 135.370079 119.855) (xy 135.447886 119.896589) + (xy 135.567125 119.93276) (xy 135.61471 119.947195) (xy 135.744723 119.96) (xy 135.744731 119.96) (xy 135.7882 119.964281) + (xy 135.797278 119.963387) (xy 135.848815 120.026185) (xy 135.945506 120.105537) (xy 136.05582 120.164502) (xy 136.175518 120.200812) + (xy 136.215 120.204701) (xy 136.215 120.497806) (xy 136.210719 120.541276) (xy 136.215 120.584745) (xy 136.215 120.584752) + (xy 136.222904 120.665001) (xy 136.227805 120.714766) (xy 136.236319 120.742833) (xy 136.278411 120.881588) (xy 136.360589 121.035334) + (xy 136.471183 121.170093) (xy 136.504956 121.19781) (xy 136.8764 121.569254) (xy 136.904117 121.603027) (xy 137.038875 121.713621) + (xy 137.192621 121.795799) (xy 137.359444 121.846405) (xy 137.489457 121.85921) (xy 137.489467 121.85921) (xy 137.532933 121.863491) + (xy 137.540046 121.86279) (xy 137.414424 121.988412) (xy 137.120583 122.428175) (xy 136.918183 122.916814) (xy 136.815 123.435551) + (xy 136.815 123.964449) (xy 136.918183 124.483186) (xy 136.923749 124.496623) (xy 136.701302 124.347989) (xy 136.392012 124.219877) + (xy 136.427932 124.133158) (xy 136.485 123.84626) (xy 136.485 123.55374) (xy 136.427932 123.266842) (xy 136.31599 122.996589) + (xy 136.153475 122.753368) (xy 135.946632 122.546525) (xy 135.703411 122.38401) (xy 135.433158 122.272068) (xy 135.14626 122.215) + (xy 134.976697 122.215) (xy 134.882327 122.175911) (xy 134.576109 122.115) (xy 134.263891 122.115) (xy 133.957673 122.175911) + (xy 133.669221 122.295391) (xy 133.409621 122.46885) (xy 133.18885 122.689621) (xy 133.015391 122.949221) (xy 132.895911 123.237673) + (xy 132.835 123.543891) (xy 132.835 123.856109) (xy 132.895911 124.162327) (xy 133.015391 124.450779) (xy 133.18885 124.710379) + (xy 133.409621 124.93115) (xy 133.669221 125.104609) (xy 133.835016 125.173283) (xy 133.797988 125.228699) (xy 133.637047 125.617245) + (xy 133.555 126.029722) (xy 133.555 126.45028) (xy 133.637047 126.862757) (xy 133.769252 127.181928) (xy 132.65 127.181928) + (xy 132.525518 127.194188) (xy 132.40582 127.230498) (xy 132.295506 127.289463) (xy 132.198815 127.368815) (xy 132.119463 127.465506) + (xy 132.060498 127.57582) (xy 132.024188 127.695518) (xy 132.011928 127.82) (xy 132.011928 128.640326) (xy 130.5396 127.167999) + (xy 130.5396 122.445157) (xy 130.582511 122.34156) (xy 130.6146 122.18024) (xy 130.6146 122.01576) (xy 130.582511 121.85444) + (xy 130.519567 121.702479) (xy 130.428187 121.565719) (xy 130.311881 121.449413) (xy 130.175121 121.358033) (xy 130.071522 121.315121) + (xy 129.845404 121.089003) (xy 129.821601 121.059999) (xy 129.705876 120.965026) (xy 129.573847 120.894454) (xy 129.430586 120.850997) + (xy 129.318933 120.84) (xy 129.318922 120.84) (xy 129.2816 120.836324) (xy 129.244278 120.84) (xy 128.767683 120.84) + (xy 128.730537 120.770506) (xy 128.651185 120.673815) (xy 128.554494 120.594463) (xy 128.44418 120.535498) (xy 128.324482 120.499188) + (xy 128.2 120.486928) (xy 126.9 120.486928) (xy 126.775518 120.499188) (xy 126.65582 120.535498) (xy 126.545506 120.594463) + (xy 126.448815 120.673815) (xy 126.369463 120.770506) (xy 126.310498 120.88082) (xy 126.274188 121.000518) (xy 126.261928 121.125) + (xy 126.261928 122.075) (xy 126.274188 122.199482) (xy 126.310498 122.31918) (xy 126.369463 122.429494) (xy 126.448815 122.526185) + (xy 126.545506 122.605537) (xy 126.65582 122.664502) (xy 126.775518 122.700812) (xy 126.9 122.713072) (xy 128.2 122.713072) + (xy 128.324482 122.700812) (xy 128.44418 122.664502) (xy 128.554494 122.605537) (xy 128.651185 122.526185) (xy 128.730537 122.429494) + (xy 128.767683 122.36) (xy 128.966799 122.36) (xy 128.996721 122.389922) (xy 129.0196 122.445157) (xy 129.0196 123.365) + (xy 128.91776 123.365) (xy 128.75644 123.397089) (xy 128.746866 123.401055) (xy 128.730537 123.370506) (xy 128.651185 123.273815) + (xy 128.554494 123.194463) (xy 128.44418 123.135498) (xy 128.324482 123.099188) (xy 128.2 123.086928) (xy 126.9 123.086928) + (xy 126.775518 123.099188) (xy 126.65582 123.135498) (xy 126.545506 123.194463) (xy 126.448815 123.273815) (xy 126.369463 123.370506) + (xy 126.310498 123.48082) (xy 126.274188 123.600518) (xy 126.261928 123.725) (xy 126.261928 124.675) (xy 126.274188 124.799482) + (xy 126.310498 124.91918) (xy 126.369463 125.029494) (xy 126.448815 125.126185) (xy 126.545506 125.205537) (xy 126.65582 125.264502) + (xy 126.775518 125.300812) (xy 126.9 125.313072) (xy 128.2 125.313072) (xy 128.324482 125.300812) (xy 128.44418 125.264502) + (xy 128.554494 125.205537) (xy 128.651185 125.126185) (xy 128.730537 125.029494) (xy 128.746866 124.998945) (xy 128.75644 125.002911) + (xy 128.91776 125.035) (xy 129.019601 125.035) (xy 129.019601 127.445468) (xy 129.015924 127.4828) (xy 129.019601 127.520133) + (xy 129.030598 127.631786) (xy 129.036621 127.651642) (xy 129.074054 127.775046) (xy 129.144626 127.907076) (xy 129.204773 127.980364) + (xy 129.2396 128.022801) (xy 129.268598 128.046599) (xy 131.841522 130.619524) (xy 131.884433 130.723121) (xy 131.975813 130.859881) + (xy 132.092119 130.976187) (xy 132.228879 131.067567) (xy 132.38084 131.130511) (xy 132.54216 131.1626) (xy 132.70664 131.1626) + (xy 132.86796 131.130511) (xy 133.019921 131.067567) (xy 133.156681 130.976187) (xy 133.272987 130.859881) (xy 133.364367 130.723121) + (xy 133.368454 130.713255) (xy 134.1002 131.445002) (xy 134.123998 131.474) (xy 134.152996 131.497798) (xy 134.239722 131.568973) + (xy 134.366218 131.636587) (xy 134.371752 131.639545) (xy 134.515013 131.683002) (xy 134.626666 131.693999) (xy 134.626675 131.693999) + (xy 134.663998 131.697675) (xy 134.701321 131.693999) (xy 137.473 131.693999) (xy 137.426999 131.74) (xy 126.937322 131.74) + (xy 126.899999 131.736324) (xy 126.862676 131.74) (xy 126.862667 131.74) (xy 126.751014 131.750997) (xy 126.631235 131.787331) + (xy 126.607753 131.794454) (xy 126.475723 131.865026) (xy 126.394815 131.931426) (xy 126.359999 131.959999) (xy 126.336201 131.988997) + (xy 125.789234 132.535964) (xy 125.789234 130.57257) (xy 126.564013 130.364969) (xy 126.68108 130.320908) (xy 126.787302 130.254856) + (xy 126.878596 130.169349) (xy 126.951455 130.067675) (xy 127.003078 129.953741) (xy 127.031481 129.831924) (xy 127.035574 129.706907) + (xy 127.015198 129.583494) (xy 126.49756 127.651642) (xy 126.453499 127.534575) (xy 126.387447 127.428353) (xy 126.30194 127.337059) + (xy 126.200266 127.2642) (xy 126.086332 127.212577) (xy 125.964515 127.184174) (xy 125.839498 127.180081) (xy 125.716085 127.200457) + (xy 123.982326 127.665016) (xy 124.030992 127.547526) (xy 124.091903 127.241308) (xy 124.091903 126.92909) (xy 124.030992 126.622872) + (xy 123.911512 126.33442) (xy 123.738053 126.07482) (xy 123.517282 125.854049) (xy 123.257682 125.68059) (xy 122.96923 125.56111) + (xy 122.663012 125.500199) (xy 122.350794 125.500199) (xy 122.044576 125.56111) (xy 121.756124 125.68059) (xy 121.588772 125.792411) + (xy 121.513508 125.807382) (xy 121.243255 125.919324) (xy 121.000034 126.081839) (xy 120.793191 126.288682) (xy 120.630676 126.531903) + (xy 120.518734 126.802156) (xy 120.461666 127.089054) (xy 120.461666 127.381574) (xy 120.518734 127.668472) (xy 120.630676 127.938725) + (xy 120.738829 128.100587) (xy 120.576595 128.208988) (xy 120.285 128.500583) (xy 120.285 128.135551) (xy 120.181817 127.616814) + (xy 119.979417 127.128175) (xy 119.685576 126.688412) (xy 119.660219 126.663055) (xy 119.75644 126.702911) (xy 119.91776 126.735) + (xy 120.08224 126.735) (xy 120.24356 126.702911) (xy 120.395521 126.639967) (xy 120.532281 126.548587) (xy 120.648587 126.432281) + (xy 120.739967 126.295521) (xy 120.802911 126.14356) (xy 120.835 125.98224) (xy 120.835 125.81776) (xy 120.802911 125.65644) + (xy 120.739967 125.504479) (xy 120.648587 125.367719) (xy 120.532281 125.251413) (xy 120.511776 125.237712) (xy 120.539967 125.195521) + (xy 120.602911 125.04356) (xy 120.635 124.88224) (xy 120.635 124.71776) (xy 120.602911 124.55644) (xy 120.56 124.452843) + (xy 120.56 124.427565) (xy 120.563676 124.390242) (xy 120.56 124.352919) (xy 120.56 124.352911) (xy 120.549003 124.241257) + (xy 120.505546 124.097996) (xy 120.434974 123.965967) (xy 120.340001 123.850242) (xy 120.311003 123.826444) (xy 120.236894 123.752335) + (xy 120.255947 123.67062) (xy 120.26004 123.545603) (xy 120.239664 123.42219) (xy 120.15787 123.116931) (xy 120.291923 122.982878) + (xy 120.395521 122.939967) (xy 120.532281 122.848587) (xy 120.648587 122.732281) (xy 120.739967 122.595521) (xy 120.802911 122.44356) + (xy 120.835 122.28224) (xy 120.835 122.11776) (xy 120.802911 121.95644) (xy 120.739967 121.804479) (xy 120.648587 121.667719) + (xy 120.631228 121.65036) (xy 121.8976 121.65036) (xy 121.8976 121.81484) (xy 121.929689 121.97616) (xy 121.992633 122.128121) + (xy 122.084013 122.264881) (xy 122.200319 122.381187) (xy 122.337079 122.472567) (xy 122.482012 122.5326) (xy 122.337079 122.592633) + (xy 122.200319 122.684013) (xy 122.084013 122.800319) (xy 121.992633 122.937079) (xy 121.929689 123.08904) (xy 121.8976 123.25036) + (xy 121.8976 123.41484) (xy 121.929689 123.57616) (xy 121.9726 123.679757) (xy 121.9726 123.895278) (xy 121.968924 123.9326) + (xy 121.9726 123.969922) (xy 121.9726 123.969932) (xy 121.983597 124.081585) (xy 122.021393 124.206185) (xy 122.027054 124.224846) + (xy 122.097626 124.356876) (xy 122.135817 124.403411) (xy 122.192599 124.472601) (xy 122.221603 124.496404) (xy 122.436196 124.710997) + (xy 122.459999 124.740001) (xy 122.575724 124.834974) (xy 122.707753 124.905546) (xy 122.762007 124.922004) (xy 122.819463 125.029494) + (xy 122.898815 125.126185) (xy 122.995506 125.205537) (xy 123.10582 125.264502) (xy 123.225518 125.300812) (xy 123.35 125.313072) + (xy 124.65 125.313072) (xy 124.774482 125.300812) (xy 124.89418 125.264502) (xy 125.004494 125.205537) (xy 125.101185 125.126185) + (xy 125.180537 125.029494) (xy 125.239502 124.91918) (xy 125.275812 124.799482) (xy 125.288072 124.675) (xy 125.288072 123.725) + (xy 125.275812 123.600518) (xy 125.239502 123.48082) (xy 125.180537 123.370506) (xy 125.101185 123.273815) (xy 125.004494 123.194463) + (xy 124.89418 123.135498) (xy 124.774482 123.099188) (xy 124.65 123.086928) (xy 123.534636 123.086928) (xy 123.472567 122.937079) + (xy 123.381187 122.800319) (xy 123.287816 122.706948) (xy 123.35 122.713072) (xy 124.65 122.713072) (xy 124.774482 122.700812) + (xy 124.89418 122.664502) (xy 125.004494 122.605537) (xy 125.101185 122.526185) (xy 125.180537 122.429494) (xy 125.239502 122.31918) + (xy 125.275812 122.199482) (xy 125.288072 122.075) (xy 125.288072 121.125) (xy 125.275812 121.000518) (xy 125.239502 120.88082) + (xy 125.180537 120.770506) (xy 125.101185 120.673815) (xy 125.004494 120.594463) (xy 124.89418 120.535498) (xy 124.774482 120.499188) + (xy 124.65 120.486928) (xy 123.35 120.486928) (xy 123.225518 120.499188) (xy 123.10582 120.535498) (xy 122.995506 120.594463) + (xy 122.898815 120.673815) (xy 122.819463 120.770506) (xy 122.779786 120.844736) (xy 122.716214 120.850997) (xy 122.572953 120.894454) + (xy 122.517699 120.923988) (xy 122.48904 120.929689) (xy 122.337079 120.992633) (xy 122.200319 121.084013) (xy 122.084013 121.200319) + (xy 121.992633 121.337079) (xy 121.929689 121.48904) (xy 121.8976 121.65036) (xy 120.631228 121.65036) (xy 120.532281 121.551413) + (xy 120.395521 121.460033) (xy 120.24356 121.397089) (xy 120.08224 121.365) (xy 119.91776 121.365) (xy 119.75644 121.397089) + (xy 119.610392 121.457584) (xy 119.533884 121.413412) (xy 118.423794 121.71086) (xy 118.42897 121.730178) (xy 118.41826 121.733048) + (xy 118.342167 121.449065) (xy 118.352878 121.446195) (xy 118.358054 121.465514) (xy 119.468144 121.168067) (xy 119.580397 120.973638) + (xy 119.527912 120.765894) (xy 119.483852 120.648826) (xy 119.417799 120.542605) (xy 119.332292 120.451311) (xy 119.230618 120.378452) + (xy 119.116684 120.32683) (xy 118.994868 120.298425) (xy 118.86985 120.294333) (xy 118.746437 120.314709) (xy 118.250505 120.450774) + (xy 118.138253 120.645199) (xy 118.097166 120.491861) (xy 118.086453 120.494731) (xy 118.027859 120.276054) (xy 118.022151 120.241484) + (xy 118.009809 120.208692) (xy 118.009807 120.208684) (xy 117.972887 120.11059) (xy 117.899032 119.991823) (xy 117.803427 119.889746) + (xy 117.689744 119.808281) (xy 117.562352 119.750561) (xy 117.426149 119.718803) (xy 117.286366 119.714227) (xy 117.286365 119.714227) + (xy 117.182953 119.7313) (xy 117.182948 119.731301) (xy 117.148377 119.737009) (xy 117.115583 119.749352) (xy 116.935 119.797739) + (xy 116.935 119.71776) (xy 116.902911 119.55644) (xy 116.839967 119.404479) (xy 116.748587 119.267719) (xy 116.632281 119.151413) + (xy 116.495521 119.060033) (xy 116.34356 118.997089) (xy 116.18224 118.965) (xy 116.01776 118.965) (xy 115.85644 118.997089) + (xy 115.752843 119.04) (xy 114.91455 119.04) (xy 114.877217 119.036323) (xy 114.839884 119.04) (xy 114.728231 119.050997) + (xy 114.58497 119.094454) (xy 114.452941 119.165026) (xy 114.337216 119.259999) (xy 114.313418 119.288997) (xy 113.555582 120.046834) + (xy 113.639967 119.920542) (xy 113.702911 119.768581) (xy 113.735 119.607261) (xy 113.735 119.442781) (xy 113.702911 119.281461) + (xy 113.639967 119.1295) (xy 113.548587 118.99274) (xy 113.515847 118.96) (xy 121.638999 118.96) (xy 121.990922 119.311923) + (xy 122.033833 119.415521) (xy 122.125213 119.552281) (xy 122.241519 119.668587) (xy 122.378279 119.759967) (xy 122.53024 119.822911) + (xy 122.69156 119.855) (xy 122.853982 119.855) (xy 122.928815 119.946185) (xy 123.025506 120.025537) (xy 123.13582 120.084502) + (xy 123.255518 120.120812) (xy 123.38 120.133072) (xy 124.68 120.133072) (xy 124.804482 120.120812) (xy 124.92418 120.084502) + (xy 125.034494 120.025537) (xy 125.131185 119.946185) (xy 125.210537 119.849494) (xy 125.269502 119.73918) (xy 125.305812 119.619482) + (xy 125.318072 119.495) (xy 125.318072 119.25) (xy 125.34064 119.25) (xy 125.50196 119.217911) (xy 125.653921 119.154967) + (xy 125.790681 119.063587) (xy 125.906987 118.947281) (xy 125.998367 118.810521) (xy 126.061311 118.65856) (xy 126.083899 118.545) + (xy 126.291928 118.545) (xy 126.291928 119.495) (xy 126.304188 119.619482) (xy 126.340498 119.73918) (xy 126.399463 119.849494) + (xy 126.478815 119.946185) (xy 126.575506 120.025537) (xy 126.68582 120.084502) (xy 126.805518 120.120812) (xy 126.93 120.133072) + (xy 128.23 120.133072) (xy 128.354482 120.120812) (xy 128.47418 120.084502) (xy 128.584494 120.025537) (xy 128.681185 119.946185) + (xy 128.756018 119.855) (xy 128.76504 119.855) (xy 128.92636 119.822911) (xy 129.078321 119.759967) (xy 129.215081 119.668587) + (xy 129.331387 119.552281) (xy 129.422767 119.415521) (xy 129.485711 119.26356) (xy 129.5178 119.10224) (xy 129.5178 118.93776) + (xy 129.485711 118.77644) (xy 129.422767 118.624479) (xy 129.331387 118.487719) (xy 129.215081 118.371413) (xy 129.078321 118.280033) + (xy 128.92636 118.217089) (xy 128.76504 118.185) (xy 128.756018 118.185) (xy 128.681185 118.093815) (xy 128.584494 118.014463) + (xy 128.47418 117.955498) (xy 128.354482 117.919188) (xy 128.23 117.906928) (xy 126.93 117.906928) (xy 126.805518 117.919188) + (xy 126.68582 117.955498) (xy 126.575506 118.014463) (xy 126.478815 118.093815) (xy 126.399463 118.190506) (xy 126.340498 118.30082) + (xy 126.304188 118.420518) (xy 126.291928 118.545) (xy 126.083899 118.545) (xy 126.0934 118.49724) (xy 126.0934 118.33276) + (xy 126.061311 118.17144) (xy 125.998367 118.019479) (xy 125.9676 117.973433) (xy 125.9676 117.475157) (xy 126.010511 117.37156) + (xy 126.032383 117.261602) (xy 129.99428 117.261602) (xy 130.031602 117.265278) (xy 130.068924 117.261602) (xy 130.068935 117.261602) + (xy 130.180588 117.250605) (xy 130.323849 117.207148) (xy 130.455878 117.136576) (xy 130.571603 117.041603) (xy 130.595405 117.0126) + (xy 131.284549 116.323456) (xy 131.313548 116.299658) (xy 131.408521 116.183933) (xy 131.479093 116.051904) (xy 131.52255 115.908643) + (xy 131.533547 115.79699) (xy 131.533547 115.796982) (xy 131.537223 115.759657) (xy 131.533547 115.722332) (xy 131.533547 113.975704) + (xy 131.576458 113.872107) (xy 131.608547 113.710787) (xy 131.608547 113.546307) (xy 131.576458 113.384987) (xy 131.513514 113.233026) + (xy 131.422134 113.096266) (xy 131.305828 112.97996) (xy 131.169068 112.88858) (xy 131.017107 112.825636) (xy 130.855787 112.793547) + (xy 130.691307 112.793547) (xy 130.529987 112.825636) (xy 130.378026 112.88858) (xy 130.241266 112.97996) (xy 130.12496 113.096266) + (xy 130.03358 113.233026) (xy 129.970636 113.384987) (xy 129.938547 113.546307) (xy 129.938547 113.710787) (xy 129.970636 113.872107) + (xy 129.98615 113.909561) (xy 128.670056 112.593468) (xy 128.569069 112.51059) (xy 128.415323 112.428412) (xy 128.26 112.381294) + (xy 128.26 111.318072) (xy 128.65 111.318072) (xy 128.774482 111.305812) (xy 128.89418 111.269502) (xy 129.004494 111.210537) + (xy 129.101185 111.131185) (xy 129.180537 111.034494) (xy 129.239502 110.92418) (xy 129.275812 110.804482) (xy 129.288072 110.68) + (xy 129.288072 108.68) (xy 129.275812 108.555518) (xy 129.239502 108.43582) (xy 129.180537 108.325506) (xy 129.101185 108.228815) + (xy 129.004494 108.149463) (xy 128.89418 108.090498) (xy 128.774482 108.054188) (xy 128.65 108.041928) (xy 126.856887 108.041928) + (xy 126.984609 107.850779) (xy 127.104089 107.562327) (xy 127.165 107.256109) (xy 127.165 106.943891) (xy 127.104089 106.637673) + (xy 126.984609 106.349221) (xy 126.81115 106.089621) (xy 126.590379 105.86885) (xy 126.330779 105.695391) (xy 126.042327 105.575911) + (xy 125.736109 105.515) (xy 125.423891 105.515) (xy 125.117673 105.575911) (xy 125.023303 105.615) (xy 124.85374 105.615) + (xy 124.566842 105.672068) (xy 124.296589 105.78401) (xy 124.053368 105.946525) (xy 123.846525 106.153368) (xy 123.68401 106.396589) + (xy 123.572068 106.666842) (xy 123.515 106.95374) (xy 123.515 107.24626) (xy 123.572068 107.533158) (xy 123.607988 107.619876) + (xy 123.298698 107.747988) (xy 123.076252 107.896622) (xy 123.081817 107.883186) (xy 123.185 107.364449) (xy 123.185 106.835551) + (xy 123.081817 106.316814) (xy 122.879417 105.828175) (xy 122.585576 105.388412) (xy 122.211588 105.014424) (xy 121.771825 104.720583) + (xy 121.384142 104.56) (xy 122.215123 104.56) (xy 122.25 104.563435) (xy 122.284877 104.56) (xy 122.389184 104.549727) + (xy 122.52302 104.509128) (xy 122.646363 104.4432) (xy 122.754475 104.354475) (xy 122.8432 104.246363) (xy 122.909128 104.12302) + (xy 122.949727 103.989184) (xy 122.963435 103.85) (xy 122.96 103.815123) (xy 122.96 103.613072) (xy 123.7 103.613072) + (xy 123.824482 103.600812) (xy 123.94418 103.564502) (xy 124.054494 103.505537) (xy 124.151185 103.426185) (xy 124.230537 103.329494) + (xy 124.289502 103.21918) (xy 124.325812 103.099482) (xy 124.338072 102.975) (xy 124.338072 102.686729) (xy 124.741923 102.282878) + (xy 124.845521 102.239967) (xy 124.982281 102.148587) (xy 125.098587 102.032281) (xy 125.189967 101.895521) (xy 125.252911 101.74356) + (xy 125.285 101.58224) (xy 125.285 101.41776) (xy 125.252911 101.25644) (xy 125.189967 101.104479) (xy 125.098587 100.967719) + (xy 124.982281 100.851413) (xy 124.845521 100.760033) (xy 124.69356 100.697089) (xy 124.53224 100.665) (xy 124.36776 100.665) + (xy 124.335 100.671516) (xy 124.335 100.597998) (xy 124.176252 100.597998) (xy 124.335 100.43925) (xy 124.338072 100.225) + (xy 124.325812 100.100518) (xy 124.289502 99.98082) (xy 124.230537 99.870506) (xy 124.151185 99.773815) (xy 124.054494 99.694463) + (xy 123.94418 99.635498) (xy 123.824482 99.599188) (xy 123.7 99.586928) (xy 123.18575 99.59) (xy 123.027002 99.748748) + (xy 123.027002 99.59) (xy 122.96 99.59) (xy 122.96 99.439) (xy 126.257197 99.439) (xy 128.726203 101.908008) + (xy 128.749997 101.937001) (xy 128.77899 101.960795) (xy 128.778994 101.960799) (xy 128.831241 102.003676) (xy 128.865722 102.031974) + (xy 128.997751 102.102546) (xy 129.141012 102.146003) (xy 129.252665 102.157) (xy 129.252674 102.157) (xy 129.289997 102.160676) + (xy 129.326263 102.157104) (xy 129.355665 102.16) (xy 129.402843 102.16) (xy 129.50644 102.202911) (xy 129.66776 102.235) + (xy 129.83224 102.235) (xy 129.912691 102.218997) (xy 129.935498 102.29418) (xy 129.994463 102.404494) (xy 130.073815 102.501185) + (xy 130.170506 102.580537) (xy 130.28082 102.639502) (xy 130.400518 102.675812) (xy 130.525 102.688072) (xy 131.475 102.688072) + (xy 131.599482 102.675812) (xy 131.71918 102.639502) (xy 131.829494 102.580537) (xy 131.926185 102.501185) (xy 132.005537 102.404494) + (xy 132.064502 102.29418) (xy 132.100812 102.174482) (xy 132.113072 102.05) (xy 132.113072 101.982618) (xy 132.165001 101.940001) + (xy 132.188803 101.910998) (xy 134.011009 100.088794) (xy 134.040001 100.065001) (xy 134.063795 100.036008) (xy 134.063799 100.036004) + (xy 134.134973 99.949277) (xy 134.134974 99.949276) (xy 134.205546 99.817247) (xy 134.249003 99.673986) (xy 134.249136 99.672634) + (xy 134.26059 99.694063) (xy 134.343468 99.79505) (xy 135.118466 100.570049) (xy 135.146179 100.603817) (xy 135.179947 100.63153) + (xy 135.179949 100.631532) (xy 135.25983 100.697089) (xy 135.280937 100.714411) (xy 135.434683 100.796589) (xy 135.601506 100.847195) + (xy 135.731519 100.86) (xy 135.731527 100.86) (xy 135.732361 100.860082) (xy 135.769463 100.929494) (xy 135.848815 101.026185) + (xy 135.945506 101.105537) (xy 136.05582 101.164502) (xy 136.175518 101.200812) (xy 136.3 101.213072) (xy 137.04 101.213072) + (xy 137.04 101.515123) (xy 137.036565 101.55) (xy 137.050273 101.689184) (xy 137.090872 101.82302) (xy 137.1568 101.946363) + (xy 137.245525 102.054475) (xy 137.330471 102.124188) (xy 137.353637 102.1432) (xy 137.47698 102.209128) (xy 137.610816 102.249727) + (xy 137.75 102.263435) (xy 137.784877 102.26) (xy 138.374436 102.26) (xy 138.228175 102.320583) (xy 137.788412 102.614424) + (xy 137.414424 102.988412) (xy 137.120583 103.428175) (xy 136.918183 103.916814) (xy 136.815 104.435551) (xy 136.815 104.964449) + (xy 136.918183 105.483186) (xy 136.923749 105.496623) (xy 136.701302 105.347989) (xy 136.392012 105.219877) (xy 136.427932 105.133158) + (xy 136.485 104.84626) (xy 136.485 104.55374) (xy 136.427932 104.266842) (xy 136.31599 103.996589) (xy 136.153475 103.753368) + (xy 135.946632 103.546525) (xy 135.703411 103.38401) (xy 135.433158 103.272068) (xy 135.14626 103.215) (xy 134.976697 103.215) + (xy 134.882327 103.175911) (xy 134.576109 103.115) (xy 134.263891 103.115) (xy 133.957673 103.175911) (xy 133.669221 103.295391) + (xy 133.409621 103.46885) (xy 133.18885 103.689621) (xy 133.015391 103.949221) (xy 132.895911 104.237673) (xy 132.835 104.543891) + (xy 132.835 104.856109) (xy 132.895911 105.162327) (xy 133.015391 105.450779) (xy 133.18885 105.710379) (xy 133.409621 105.93115) + (xy 133.669221 106.104609) (xy 133.835016 106.173283) (xy 133.797988 106.228699) (xy 133.637047 106.617245) (xy 133.555 107.029722) + (xy 133.555 107.45028) (xy 133.637047 107.862757) (xy 133.769252 108.181928) (xy 132.65 108.181928) (xy 132.56 108.190792) + (xy 132.56 105.787323) (xy 132.563676 105.75) (xy 132.56 105.712677) (xy 132.56 105.612667) (xy 132.549003 105.501014) + (xy 132.505546 105.357753) (xy 132.434974 105.225724) (xy 132.340001 105.109999) (xy 132.224276 105.015026) (xy 132.113072 104.955585) + (xy 132.113072 104.3) (xy 132.100812 104.175518) (xy 132.064502 104.05582) (xy 132.005537 103.945506) (xy 131.926185 103.848815) + (xy 131.829494 103.769463) (xy 131.71918 103.710498) (xy 131.599482 103.674188) (xy 131.475 103.661928) (xy 130.525 103.661928) + (xy 130.400518 103.674188) (xy 130.28082 103.710498) (xy 130.170506 103.769463) (xy 130.073815 103.848815) (xy 129.994463 103.945506) + (xy 129.935498 104.05582) (xy 129.899188 104.175518) (xy 129.886928 104.3) (xy 129.886928 105.6) (xy 129.899188 105.724482) + (xy 129.935498 105.84418) (xy 129.994463 105.954494) (xy 130.073815 106.051185) (xy 130.170506 106.130537) (xy 130.28082 106.189502) + (xy 130.400518 106.225812) (xy 130.525 106.238072) (xy 131.040001 106.238072) (xy 131.04 108.602843) (xy 130.997089 108.70644) + (xy 130.965 108.86776) (xy 130.965 109.03224) (xy 130.997089 109.19356) (xy 131.040001 109.297159) (xy 131.04 111.712679) + (xy 131.036324 111.750002) (xy 131.04 111.787324) (xy 131.04 111.787334) (xy 131.050997 111.898987) (xy 131.083592 112.00644) + (xy 131.094454 112.042248) (xy 131.165026 112.174278) (xy 131.19736 112.213677) (xy 131.259999 112.290003) (xy 131.289002 112.313805) + (xy 131.961204 112.986009) (xy 131.984998 113.015002) (xy 132.013991 113.038796) (xy 132.013995 113.0388) (xy 132.064198 113.08) + (xy 132.100723 113.109975) (xy 132.232752 113.180547) (xy 132.376013 113.224004) (xy 132.487666 113.235001) (xy 132.487675 113.235001) + (xy 132.524998 113.238677) (xy 132.562321 113.235001) (xy 145.487677 113.235001) (xy 145.524999 113.238677) (xy 145.562321 113.235001) + (xy 145.562332 113.235001) (xy 145.673985 113.224004) (xy 145.817246 113.180547) (xy 145.949275 113.109975) (xy 146.065 113.015002) + (xy 146.068071 113.01126) (xy 151.565 113.01126) (xy 151.565 113.17574) (xy 151.597089 113.33706) (xy 151.660033 113.489021) + (xy 151.751413 113.625781) (xy 151.867719 113.742087) (xy 152.004479 113.833467) (xy 152.15644 113.896411) (xy 152.31776 113.9285) + (xy 152.48224 113.9285) (xy 152.64356 113.896411) (xy 152.795521 113.833467) (xy 152.860275 113.7902) (xy 154.339043 113.7902) + (xy 154.44264 113.833111) (xy 154.60396 113.8652) (xy 154.76844 113.8652) (xy 154.92976 113.833111) (xy 155.081721 113.770167) + (xy 155.218481 113.678787) (xy 155.334787 113.562481) (xy 155.426167 113.425721) (xy 155.489111 113.27376) (xy 155.5212 113.11244) + (xy 155.5212 112.94796) (xy 155.489111 112.78664) (xy 155.426167 112.634679) (xy 155.334787 112.497919) (xy 155.218481 112.381613) + (xy 155.081721 112.290233) (xy 154.92976 112.227289) (xy 154.76844 112.1952) (xy 154.60396 112.1952) (xy 154.44264 112.227289) + (xy 154.339043 112.2702) (xy 152.541059 112.2702) (xy 152.48224 112.2585) (xy 152.31776 112.2585) (xy 152.15644 112.290589) + (xy 152.004479 112.353533) (xy 151.867719 112.444913) (xy 151.751413 112.561219) (xy 151.660033 112.697979) (xy 151.597089 112.84994) + (xy 151.565 113.01126) (xy 146.068071 113.01126) (xy 146.088803 112.985999) (xy 147.011003 112.063799) (xy 147.040001 112.040001) + (xy 147.134974 111.924276) (xy 147.205546 111.792247) (xy 147.249003 111.648986) (xy 147.26 111.537333) (xy 147.26 111.537325) + (xy 147.263676 111.5) (xy 147.26 111.462675) (xy 147.26 108.918072) (xy 147.65 108.918072) (xy 147.774482 108.905812) + (xy 147.89418 108.869502) (xy 148.004494 108.810537) (xy 148.101185 108.731185) (xy 148.180537 108.634494) (xy 148.239502 108.52418) + (xy 148.275812 108.404482) (xy 148.288072 108.28) (xy 148.288072 106.28) (xy 148.275812 106.155518) (xy 148.239502 106.03582) + (xy 148.180537 105.925506) (xy 148.101185 105.828815) (xy 148.004494 105.749463) (xy 147.89418 105.690498) (xy 147.774482 105.654188) + (xy 147.65 105.641928) (xy 145.856887 105.641928) (xy 145.984609 105.450779) (xy 146.104089 105.162327) (xy 146.165 104.856109) + (xy 146.165 104.543891) (xy 146.104089 104.237673) (xy 145.984609 103.949221) (xy 145.81115 103.689621) (xy 145.590379 103.46885) + (xy 145.330779 103.295391) (xy 145.042327 103.175911) (xy 144.736109 103.115) (xy 144.423891 103.115) (xy 144.117673 103.175911) + (xy 144.023303 103.215) (xy 143.85374 103.215) (xy 143.566842 103.272068) (xy 143.296589 103.38401) (xy 143.053368 103.546525) + (xy 142.846525 103.753368) (xy 142.68401 103.996589) (xy 142.572068 104.266842) (xy 142.515 104.55374) (xy 142.515 104.84626) + (xy 142.572068 105.133158) (xy 142.607988 105.219876) (xy 142.298698 105.347988) (xy 142.076252 105.496622) (xy 142.081817 105.483186) + (xy 142.185 104.964449) (xy 142.185 104.435551) (xy 142.081817 103.916814) (xy 141.879417 103.428175) (xy 141.585576 102.988412) + (xy 141.211588 102.614424) (xy 140.771825 102.320583) (xy 140.625564 102.26) (xy 141.215123 102.26) (xy 141.25 102.263435) + (xy 141.284877 102.26) (xy 141.389184 102.249727) (xy 141.52302 102.209128) (xy 141.646363 102.1432) (xy 141.754475 102.054475) + (xy 141.8432 101.946363) (xy 141.909128 101.82302) (xy 141.949727 101.689184) (xy 141.963435 101.55) (xy 141.96 101.515123) + (xy 141.96 101.213072) (xy 142.7 101.213072) (xy 142.824482 101.200812) (xy 142.94418 101.164502) (xy 143.054494 101.105537) + (xy 143.151185 101.026185) (xy 143.230537 100.929494) (xy 143.289502 100.81918) (xy 143.325812 100.699482) (xy 143.330979 100.647014) + (xy 143.400276 100.609974) (xy 143.516001 100.515001) (xy 143.539803 100.485998) (xy 144.111004 99.914798) (xy 144.140001 99.891001) + (xy 144.234974 99.775276) (xy 144.305546 99.643247) (xy 144.349003 99.499986) (xy 144.35886 99.39991) (xy 144.402911 99.29356) + (xy 144.435 99.13224) (xy 144.435 98.96776) (xy 144.402911 98.80644) (xy 144.339967 98.654479) (xy 144.248587 98.517719) + (xy 144.132281 98.401413) (xy 143.995521 98.310033) (xy 143.84356 98.247089) (xy 143.68224 98.215) (xy 143.51776 98.215) + (xy 143.35644 98.247089) (xy 143.335 98.25597) (xy 143.335 98.197998) (xy 143.176252 98.197998) (xy 143.335 98.03925) + (xy 143.338072 97.825) (xy 143.325812 97.700518) (xy 143.289502 97.58082) (xy 143.230537 97.470506) (xy 143.151185 97.373815) + (xy 143.054494 97.294463) (xy 142.94418 97.235498) (xy 142.824482 97.199188) (xy 142.7 97.186928) (xy 142.18575 97.19) + (xy 142.027002 97.348748) (xy 142.027002 97.19) (xy 141.96 97.19) (xy 141.96 97.084877) (xy 141.963435 97.05) + (xy 141.949727 96.910816) (xy 141.909128 96.77698) (xy 141.8432 96.653637) (xy 141.754475 96.545525) (xy 141.646363 96.4568) + (xy 141.52302 96.390872) (xy 141.389184 96.350273) (xy 141.284877 96.34) (xy 141.25 96.336565) (xy 141.215123 96.34) + (xy 137.784877 96.34) (xy 137.75 96.336565) (xy 137.715123 96.34) (xy 137.610816 96.350273) (xy 137.47698 96.390872) + (xy 137.353637 96.4568) (xy 137.245525 96.545525) (xy 137.1568 96.653637) (xy 137.090872 96.77698) (xy 137.050273 96.910816) + (xy 137.036565 97.05) (xy 137.040001 97.084887) (xy 137.040001 97.186928) (xy 136.3 97.186928) (xy 136.175518 97.199188) + (xy 136.05582 97.235498) (xy 135.945506 97.294463) (xy 135.848815 97.373815) (xy 135.769463 97.470506) (xy 135.757338 97.493189) + (xy 135.670753 97.519454) (xy 135.538724 97.590026) (xy 135.422999 97.684999) (xy 135.399196 97.714003) (xy 135.189013 97.924186) + (xy 135.160009 97.947989) (xy 135.112781 98.005537) (xy 135.065036 98.063714) (xy 135.001431 98.182709) (xy 134.994464 98.195744) + (xy 134.958342 98.314826) (xy 134.82651 98.327809) (xy 134.659687 98.378416) (xy 134.505941 98.460594) (xy 134.371183 98.571187) + (xy 134.26059 98.705945) (xy 134.26 98.707049) (xy 134.26 96.614801) (xy 135.859999 95.014804) (xy 135.860008 95.014793) + (xy 135.964801 94.91) (xy 149.240001 94.91) (xy 149.240001 95.572317) (xy 149.170506 95.609463) (xy 149.073815 95.688815) + (xy 148.994463 95.785506) (xy 148.935498 95.89582) (xy 148.899188 96.015518) (xy 148.886928 96.14) (xy 148.886928 97.44) + (xy 148.899188 97.564482) (xy 148.935498 97.68418) (xy 148.994463 97.794494) (xy 149.073815 97.891185) (xy 149.165 97.966018) + (xy 149.165 98.02224) (xy 149.197089 98.18356) (xy 149.260033 98.335521) (xy 149.351413 98.472281) (xy 149.467719 98.588587) + (xy 149.604479 98.679967) (xy 149.75644 98.742911) (xy 149.91776 98.775) (xy 150.08224 98.775) (xy 150.24356 98.742911) + (xy 150.395521 98.679967) (xy 150.532281 98.588587) (xy 150.648587 98.472281) (xy 150.739967 98.335521) (xy 150.802911 98.18356) + (xy 150.835 98.02224) (xy 150.835 97.966018) (xy 150.926185 97.891185) (xy 151.005537 97.794494) (xy 151.064502 97.68418) + (xy 151.100812 97.564482) (xy 151.113072 97.44) (xy 151.113072 96.14) (xy 151.100812 96.015518) (xy 151.064502 95.89582) + (xy 151.005537 95.785506) (xy 150.926185 95.688815) (xy 150.829494 95.609463) (xy 150.76 95.572317) (xy 150.76 94.459601) + (xy 151.546402 93.6732) (xy 154.487453 93.6732) (xy 154.524775 93.676876) (xy 154.562097 93.6732) (xy 154.562108 93.6732) + (xy 154.673761 93.662203) (xy 154.817022 93.618746) (xy 154.949051 93.548174) (xy 154.969378 93.531492) (xy 155.004479 93.554946) + (xy 155.108077 93.597858) (xy 155.440001 93.929782) (xy 155.440001 94.676928) (xy 155.4 94.676928) (xy 155.275518 94.689188) + (xy 155.15582 94.725498) (xy 155.045506 94.784463) (xy 154.948815 94.863815) (xy 154.869463 94.960506) (xy 154.810498 95.07082) + (xy 154.774188 95.190518) (xy 154.761928 95.315) (xy 154.761928 95.705) (xy 154.66776 95.705) (xy 154.50644 95.737089) + (xy 154.457685 95.757284) (xy 154.378817 95.661183) (xy 154.244059 95.550589) (xy 154.090313 95.468411) (xy 153.92349 95.417805) + (xy 153.75 95.400718) (xy 153.576511 95.417805) (xy 153.409688 95.468411) (xy 153.255942 95.550589) (xy 153.121183 95.661183) + (xy 153.010589 95.795941) (xy 152.928411 95.949687) (xy 152.877805 96.11651) (xy 152.865 96.246523) (xy 152.865 96.458533) + (xy 152.860719 96.502002) (xy 152.865 96.545471) (xy 152.865 96.545478) (xy 152.875085 96.647877) (xy 152.877805 96.675492) + (xy 152.884989 96.699173) (xy 152.928411 96.842314) (xy 153.010589 96.99606) (xy 153.121183 97.130819) (xy 153.154956 97.158536) + (xy 154.156468 98.160049) (xy 154.184181 98.193817) (xy 154.217949 98.22153) (xy 154.217951 98.221532) (xy 154.262088 98.257754) + (xy 154.318939 98.304411) (xy 154.472685 98.386589) (xy 154.639508 98.437195) (xy 154.769521 98.45) (xy 154.769531 98.45) + (xy 154.812997 98.454281) (xy 154.856463 98.45) (xy 154.894499 98.45) (xy 154.948815 98.516185) (xy 155.045506 98.595537) + (xy 155.15582 98.654502) (xy 155.275518 98.690812) (xy 155.315001 98.694701) (xy 155.315001 99.101521) (xy 155.310719 99.145) + (xy 155.327805 99.31849) (xy 155.378412 99.485313) (xy 155.46059 99.639059) (xy 155.543468 99.740046) (xy 155.543471 99.740049) + (xy 155.571184 99.773817) (xy 155.604952 99.80153) (xy 155.938466 100.135044) (xy 155.966183 100.168817) (xy 156.100941 100.279411) + (xy 156.254687 100.361589) (xy 156.42151 100.412195) (xy 156.551523 100.425) (xy 156.551533 100.425) (xy 156.566374 100.426462) + (xy 156.514424 100.478412) (xy 156.220583 100.918175) (xy 156.018183 101.406814) (xy 155.915 101.925551) (xy 155.915 102.454449) + (xy 156.018183 102.973186) (xy 156.023749 102.986623) (xy 155.801302 102.837989) (xy 155.492012 102.709877) (xy 155.527932 102.623158) + (xy 155.585 102.33626) (xy 155.585 102.04374) (xy 155.527932 101.756842) (xy 155.41599 101.486589) (xy 155.253475 101.243368) + (xy 155.046632 101.036525) (xy 154.803411 100.87401) (xy 154.533158 100.762068) (xy 154.24626 100.705) (xy 154.076697 100.705) + (xy 153.982327 100.665911) (xy 153.676109 100.605) (xy 153.363891 100.605) (xy 153.057673 100.665911) (xy 152.769221 100.785391) + (xy 152.509621 100.95885) (xy 152.28885 101.179621) (xy 152.115391 101.439221) (xy 151.995911 101.727673) (xy 151.935 102.033891) + (xy 151.935 102.346109) (xy 151.995911 102.652327) (xy 152.115391 102.940779) (xy 152.28885 103.200379) (xy 152.509621 103.42115) + (xy 152.769221 103.594609) (xy 152.935016 103.663283) (xy 152.897988 103.718699) (xy 152.737047 104.107245) (xy 152.655 104.519722) + (xy 152.655 104.94028) (xy 152.737047 105.352757) (xy 152.869252 105.671928) (xy 151.75 105.671928) (xy 151.66 105.680792) + (xy 151.66 101.277322) (xy 151.663676 101.239999) (xy 151.66 101.202676) (xy 151.66 101.202667) (xy 151.649003 101.091014) + (xy 151.605546 100.947753) (xy 151.534974 100.815724) (xy 151.440001 100.699999) (xy 151.411003 100.676201) (xy 151.113072 100.37827) + (xy 151.113072 99.69) (xy 151.100812 99.565518) (xy 151.064502 99.44582) (xy 151.005537 99.335506) (xy 150.926185 99.238815) + (xy 150.829494 99.159463) (xy 150.71918 99.100498) (xy 150.599482 99.064188) (xy 150.475 99.051928) (xy 149.525 99.051928) + (xy 149.400518 99.064188) (xy 149.28082 99.100498) (xy 149.170506 99.159463) (xy 149.073815 99.238815) (xy 148.994463 99.335506) + (xy 148.935498 99.44582) (xy 148.899188 99.565518) (xy 148.886928 99.69) (xy 148.886928 100.99) (xy 148.899188 101.114482) + (xy 148.935498 101.23418) (xy 148.994463 101.344494) (xy 149.073815 101.441185) (xy 149.170506 101.520537) (xy 149.28082 101.579502) + (xy 149.400518 101.615812) (xy 149.525 101.628072) (xy 150.140001 101.628072) (xy 150.14 106.192843) (xy 150.097089 106.29644) + (xy 150.065 106.45776) (xy 150.065 106.62224) (xy 150.097089 106.78356) (xy 150.140001 106.887159) (xy 150.14 109.302679) + (xy 150.136324 109.340002) (xy 150.14 109.377324) (xy 150.14 109.377334) (xy 150.150997 109.488987) (xy 150.179297 109.582281) + (xy 150.194454 109.632248) (xy 150.265026 109.764278) (xy 150.295009 109.800812) (xy 150.359999 109.880003) (xy 150.389002 109.903805) + (xy 151.061204 110.576009) (xy 151.084998 110.605002) (xy 151.113991 110.628796) (xy 151.113995 110.6288) (xy 151.175187 110.679018) + (xy 151.200723 110.699975) (xy 151.332752 110.770547) (xy 151.476013 110.814004) (xy 151.587666 110.825001) (xy 151.587675 110.825001) + (xy 151.624998 110.828677) (xy 151.662321 110.825001) (xy 164.587677 110.825001) (xy 164.624999 110.828677) (xy 164.662321 110.825001) + (xy 164.662332 110.825001) (xy 164.773985 110.814004) (xy 164.917246 110.770547) (xy 165.049275 110.699975) (xy 165.165 110.605002) + (xy 165.188803 110.575999) (xy 166.111003 109.653799) (xy 166.140001 109.630001) (xy 166.234974 109.514276) (xy 166.305546 109.382247) + (xy 166.349003 109.238986) (xy 166.36 109.127333) (xy 166.36 109.127325) (xy 166.363676 109.09) (xy 166.36 109.052675) + (xy 166.36 106.408072) (xy 166.75 106.408072) (xy 166.874482 106.395812) (xy 166.99418 106.359502) (xy 167.104494 106.300537) + (xy 167.201185 106.221185) (xy 167.280537 106.124494) (xy 167.339502 106.01418) (xy 167.375812 105.894482) (xy 167.388072 105.77) + (xy 167.388072 103.77) (xy 167.375812 103.645518) (xy 167.339502 103.52582) (xy 167.280537 103.415506) (xy 167.201185 103.318815) + (xy 167.104494 103.239463) (xy 166.99418 103.180498) (xy 166.874482 103.144188) (xy 166.75 103.131928) (xy 164.956887 103.131928) + (xy 165.084609 102.940779) (xy 165.204089 102.652327) (xy 165.265 102.346109) (xy 165.265 102.033891) (xy 165.204089 101.727673) + (xy 165.084609 101.439221) (xy 164.91115 101.179621) (xy 164.690379 100.95885) (xy 164.430779 100.785391) (xy 164.142327 100.665911) + (xy 163.836109 100.605) (xy 163.523891 100.605) (xy 163.217673 100.665911) (xy 163.123303 100.705) (xy 162.95374 100.705) + (xy 162.666842 100.762068) (xy 162.396589 100.87401) (xy 162.153368 101.036525) (xy 161.946525 101.243368) (xy 161.78401 101.486589) + (xy 161.672068 101.756842) (xy 161.615 102.04374) (xy 161.615 102.33626) (xy 161.672068 102.623158) (xy 161.707988 102.709876) + (xy 161.398698 102.837988) (xy 161.176252 102.986622) (xy 161.181817 102.973186) (xy 161.285 102.454449) (xy 161.285 101.925551) + (xy 161.181817 101.406814) (xy 160.979417 100.918175) (xy 160.685576 100.478412) (xy 160.632164 100.425) (xy 165.556511 100.425) + (xy 165.59998 100.429281) (xy 165.643449 100.425) (xy 165.643457 100.425) (xy 165.77347 100.412195) (xy 165.940293 100.361589) + (xy 166.094039 100.279411) (xy 166.228797 100.168817) (xy 166.256514 100.135044) (xy 167.081522 99.310037) (xy 167.1644 99.20905) + (xy 167.246578 99.055304) (xy 167.297184 98.888481) (xy 167.314271 98.714991) (xy 167.297184 98.541501) (xy 167.246578 98.374677) + (xy 167.1644 98.220932) (xy 167.053807 98.086173) (xy 166.919048 97.97558) (xy 166.765303 97.893402) (xy 166.598479 97.842796) + (xy 166.424989 97.825709) (xy 166.251499 97.842796) (xy 166.084676 97.893402) (xy 165.93093 97.97558) (xy 165.829943 98.058458) + (xy 165.233402 98.655) (xy 162.042538 98.655) (xy 162.04418 98.654502) (xy 162.154494 98.595537) (xy 162.251185 98.516185) + (xy 162.330537 98.419494) (xy 162.381046 98.325) (xy 162.687678 98.325) (xy 162.725 98.328676) (xy 162.762322 98.325) + (xy 162.762333 98.325) (xy 162.873986 98.314003) (xy 163.017247 98.270546) (xy 163.149276 98.199974) (xy 163.265001 98.105001) + (xy 163.288803 98.075998) (xy 163.811004 97.553798) (xy 163.840001 97.530001) (xy 163.934974 97.414276) (xy 164.005546 97.282247) + (xy 164.049003 97.138986) (xy 164.06 97.027333) (xy 164.06 97.027325) (xy 164.063676 96.99) (xy 164.06 96.952675) + (xy 164.06 96.014134) (xy 164.063676 95.976812) (xy 164.06 95.939489) (xy 164.06 95.939479) (xy 164.049003 95.827826) + (xy 164.005546 95.684565) (xy 163.987725 95.651224) (xy 163.934974 95.552535) (xy 163.863799 95.465809) (xy 163.840001 95.436811) + (xy 163.811003 95.413013) (xy 162.576992 94.179003) (xy 162.553189 94.149999) (xy 162.437464 94.055026) (xy 162.305435 93.984454) + (xy 162.162174 93.940997) (xy 162.050521 93.93) (xy 162.05051 93.93) (xy 162.013188 93.926324) (xy 161.975866 93.93) + (xy 161.797157 93.93) (xy 161.69356 93.887089) (xy 161.53224 93.855) (xy 161.36776 93.855) (xy 161.20644 93.887089) + (xy 161.054479 93.950033) (xy 160.937873 94.027946) (xy 160.854475 93.926325) (xy 160.746363 93.8376) (xy 160.62302 93.771672) + (xy 160.489184 93.731073) (xy 160.384877 93.7208) (xy 160.35 93.717365) (xy 160.315123 93.7208) (xy 156.96 93.7208) + (xy 156.96 93.652302) (xy 156.963676 93.614979) (xy 156.96 93.577656) (xy 156.96 93.577646) (xy 156.949003 93.465993) + (xy 156.905546 93.322732) (xy 156.834974 93.190703) (xy 156.740001 93.074978) (xy 156.711002 93.05118) (xy 156.7098 93.049977) + (xy 163.935176 93.049977) (xy 165.5462 94.661002) (xy 165.57 94.690002) (xy 165.685725 94.784975) (xy 165.817754 94.855547) + (xy 165.961015 94.899004) (xy 166.072668 94.910001) (xy 166.072677 94.910001) (xy 166.11 94.913677) (xy 166.147323 94.910001) + (xy 168.490001 94.910001) (xy 168.49 98.552843) (xy 168.447089 98.65644) (xy 168.415 98.81776) (xy 168.415 98.98224) + (xy 168.447089 99.14356) (xy 168.459533 99.173602) (xy 168.420506 99.194463) (xy 168.323815 99.273815) (xy 168.244463 99.370506) + (xy 168.185498 99.48082) (xy 168.149188 99.600518) (xy 168.136928 99.725) (xy 168.136928 101.025) (xy 168.149188 101.149482) + (xy 168.185498 101.26918) (xy 168.244463 101.379494) (xy 168.323815 101.476185) (xy 168.420506 101.555537) (xy 168.53082 101.614502) + (xy 168.650518 101.650812) (xy 168.775 101.663072) (xy 169.725 101.663072) (xy 169.849482 101.650812) (xy 169.96918 101.614502) + (xy 170.079494 101.555537) (xy 170.176185 101.476185) (xy 170.255537 101.379494) (xy 170.314502 101.26918) (xy 170.350812 101.149482) + (xy 170.363072 101.025) (xy 170.363072 99.725) (xy 170.350812 99.600518) (xy 170.314502 99.48082) (xy 170.255537 99.370506) + (xy 170.176185 99.273815) (xy 170.079494 99.194463) (xy 170.040467 99.173602) (xy 170.052911 99.14356) (xy 170.085 98.98224) + (xy 170.085 98.81776) (xy 170.052911 98.65644) (xy 170.01 98.552843) (xy 170.01 95.51) (xy 170.08224 95.51) + (xy 170.24356 95.477911) (xy 170.395521 95.414967) (xy 170.402955 95.41) (xy 181.185199 95.41) (xy 182.649602 96.874404) + (xy 182.6734 96.903402) (xy 182.702398 96.9272) (xy 182.789124 96.998375) (xy 182.857706 97.035033) (xy 182.921154 97.068947) + (xy 183.064415 97.112404) (xy 183.176068 97.123401) (xy 183.176078 97.123401) (xy 183.213401 97.127077) (xy 183.250724 97.123401) + (xy 185.127842 97.123401) (xy 185.231439 97.166312) (xy 185.392759 97.198401) (xy 185.557239 97.198401) (xy 185.718559 97.166312) + (xy 185.87052 97.103368) (xy 186.00728 97.011988) (xy 186.123586 96.895682) (xy 186.214966 96.758922) (xy 186.27791 96.606961) + (xy 186.309999 96.445641) (xy 186.309999 96.281161) (xy 186.27791 96.119841) (xy 186.214966 95.96788) (xy 186.123586 95.83112) + (xy 186.00728 95.714814) (xy 185.87052 95.623434) (xy 185.718559 95.56049) (xy 185.557239 95.528401) (xy 185.392759 95.528401) + (xy 185.231439 95.56049) (xy 185.127842 95.603401) (xy 183.528203 95.603401) (xy 183.061957 95.137155) (xy 183.101014 95.149003) + (xy 183.212667 95.16) (xy 183.212676 95.16) (xy 183.249999 95.163676) (xy 183.287322 95.16) (xy 185.652843 95.16) + (xy 185.75644 95.202911) (xy 185.91776 95.235) (xy 186.08224 95.235) (xy 186.24356 95.202911) (xy 186.395521 95.139967) + (xy 186.532281 95.048587) (xy 186.648587 94.932281) (xy 186.739967 94.795521) (xy 186.802911 94.64356) (xy 186.835 94.48224) + (xy 186.835 94.31776) (xy 186.802911 94.15644) (xy 186.739967 94.004479) (xy 186.648587 93.867719) (xy 186.532281 93.751413) + (xy 186.395521 93.660033) (xy 186.24356 93.597089) (xy 186.08224 93.565) (xy 185.91776 93.565) (xy 185.75644 93.597089) + (xy 185.652843 93.64) (xy 184.534801 93.64) (xy 185.111003 93.063799) (xy 185.140001 93.040001) (xy 185.234974 92.924276) + (xy 185.305546 92.792247) (xy 185.349003 92.648986) (xy 185.36 92.537333) (xy 185.36 92.537325) (xy 185.363676 92.5) + (xy 185.36 92.462675) (xy 185.36 89.9) (xy 187.386928 89.9) (xy 187.386928 91.2) (xy 187.399188 91.324482) + (xy 187.435498 91.44418) (xy 187.494463 91.554494) (xy 187.573815 91.651185) (xy 187.665 91.726018) (xy 187.665 91.83224) + (xy 187.697089 91.99356) (xy 187.760033 92.145521) (xy 187.851413 92.282281) (xy 187.967719 92.398587) (xy 188.104479 92.489967) + (xy 188.25644 92.552911) (xy 188.41776 92.585) (xy 188.58224 92.585) (xy 188.74356 92.552911) (xy 188.895521 92.489967) + (xy 189.032281 92.398587) (xy 189.148587 92.282281) (xy 189.239967 92.145521) (xy 189.302911 91.99356) (xy 189.335 91.83224) + (xy 189.335 91.726018) (xy 189.426185 91.651185) (xy 189.505537 91.554494) (xy 189.564502 91.44418) (xy 189.600812 91.324482) + (xy 189.613072 91.2) (xy 189.613072 89.9) (xy 189.600812 89.775518) (xy 189.564502 89.65582) (xy 189.505537 89.545506) + (xy 189.426185 89.448815) (xy 189.329494 89.369463) (xy 189.21918 89.310498) (xy 189.099482 89.274188) (xy 188.975 89.261928) + (xy 188.025 89.261928) (xy 187.900518 89.274188) (xy 187.78082 89.310498) (xy 187.670506 89.369463) (xy 187.573815 89.448815) + (xy 187.494463 89.545506) (xy 187.435498 89.65582) (xy 187.399188 89.775518) (xy 187.386928 89.9) (xy 185.36 89.9) + (xy 185.36 89.818072) (xy 185.75 89.818072) (xy 185.874482 89.805812) (xy 185.99418 89.769502) (xy 186.104494 89.710537) + (xy 186.201185 89.631185) (xy 186.280537 89.534494) (xy 186.339502 89.42418) (xy 186.375812 89.304482) (xy 186.388072 89.18) + (xy 186.388072 87.18) (xy 186.375812 87.055518) (xy 186.339502 86.93582) (xy 186.280537 86.825506) (xy 186.201185 86.728815) + (xy 186.104494 86.649463) (xy 185.99418 86.590498) (xy 185.874482 86.554188) (xy 185.75 86.541928) (xy 183.956887 86.541928) + (xy 184.084609 86.350779) (xy 184.204089 86.062327) (xy 184.265 85.756109) (xy 184.265 85.443891) (xy 184.204089 85.137673) + (xy 184.084609 84.849221) (xy 183.91115 84.589621) (xy 183.690379 84.36885) (xy 183.430779 84.195391) (xy 183.142327 84.075911) + (xy 182.836109 84.015) (xy 182.523891 84.015) (xy 182.217673 84.075911) (xy 182.123303 84.115) (xy 181.95374 84.115) + (xy 181.666842 84.172068) (xy 181.396589 84.28401) (xy 181.153368 84.446525) (xy 180.946525 84.653368) (xy 180.78401 84.896589) + (xy 180.672068 85.166842) (xy 180.615 85.45374) (xy 180.615 85.74626) (xy 180.672068 86.033158) (xy 180.707988 86.119876) + (xy 180.398698 86.247988) (xy 180.176252 86.396622) (xy 180.181817 86.383186) (xy 180.285 85.864449) (xy 180.285 85.335551) + (xy 180.181817 84.816814) (xy 179.979417 84.328175) (xy 179.685576 83.888412) (xy 179.457164 83.66) (xy 183.789324 83.66) + (xy 183.90644 83.708511) (xy 184.06776 83.7406) (xy 184.23224 83.7406) (xy 184.39356 83.708511) (xy 184.545521 83.645567) + (xy 184.682281 83.554187) (xy 184.798587 83.437881) (xy 184.889967 83.301121) (xy 184.952911 83.14916) (xy 184.985 82.98784) + (xy 184.985 82.82336) (xy 185.1946 82.82336) (xy 185.1946 82.98784) (xy 185.226689 83.14916) (xy 185.289633 83.301121) + (xy 185.381013 83.437881) (xy 185.497319 83.554187) (xy 185.634079 83.645567) (xy 185.737678 83.688479) (xy 187.74 85.690802) + (xy 187.74 85.782317) (xy 187.670506 85.819463) (xy 187.573815 85.898815) (xy 187.494463 85.995506) (xy 187.435498 86.10582) + (xy 187.399188 86.225518) (xy 187.386928 86.35) (xy 187.386928 87.65) (xy 187.399188 87.774482) (xy 187.435498 87.89418) + (xy 187.494463 88.004494) (xy 187.573815 88.101185) (xy 187.665 88.176018) (xy 187.665 88.33224) (xy 187.697089 88.49356) + (xy 187.760033 88.645521) (xy 187.851413 88.782281) (xy 187.967719 88.898587) (xy 188.104479 88.989967) (xy 188.25644 89.052911) + (xy 188.41776 89.085) (xy 188.58224 89.085) (xy 188.74356 89.052911) (xy 188.895521 88.989967) (xy 189.032281 88.898587) + (xy 189.148587 88.782281) (xy 189.239967 88.645521) (xy 189.302911 88.49356) (xy 189.335 88.33224) (xy 189.335 88.176018) + (xy 189.426185 88.101185) (xy 189.505537 88.004494) (xy 189.564502 87.89418) (xy 189.600812 87.774482) (xy 189.613072 87.65) + (xy 189.613072 86.35) (xy 189.600812 86.225518) (xy 189.564502 86.10582) (xy 189.505537 85.995506) (xy 189.426185 85.898815) + (xy 189.329494 85.819463) (xy 189.26 85.782317) (xy 189.26 85.413322) (xy 189.263676 85.375999) (xy 189.26 85.338676) + (xy 189.26 85.338667) (xy 189.249003 85.227014) (xy 189.205546 85.083753) (xy 189.134974 84.951724) (xy 189.040001 84.835999) + (xy 189.011004 84.812202) (xy 186.812479 82.613678) (xy 186.769567 82.510079) (xy 186.678187 82.373319) (xy 186.561881 82.257013) + (xy 186.425121 82.165633) (xy 186.27316 82.102689) (xy 186.11184 82.0706) (xy 185.94736 82.0706) (xy 185.78604 82.102689) + (xy 185.634079 82.165633) (xy 185.497319 82.257013) (xy 185.381013 82.373319) (xy 185.289633 82.510079) (xy 185.226689 82.66204) + (xy 185.1946 82.82336) (xy 184.985 82.82336) (xy 184.952911 82.66204) (xy 184.889967 82.510079) (xy 184.798587 82.373319) + (xy 184.682281 82.257013) (xy 184.545521 82.165633) (xy 184.39356 82.102689) (xy 184.23224 82.0706) (xy 184.06776 82.0706) + (xy 183.90644 82.102689) (xy 183.816363 82.14) (xy 180.06 82.14) (xy 180.06 82.113072) (xy 180.8 82.113072) + (xy 180.924482 82.100812) (xy 181.04418 82.064502) (xy 181.154494 82.005537) (xy 181.251185 81.926185) (xy 181.330537 81.829494) + (xy 181.389502 81.71918) (xy 181.425812 81.599482) (xy 181.431418 81.542562) (xy 181.465001 81.515001) (xy 181.488803 81.485998) + (xy 181.891923 81.082878) (xy 181.995521 81.039967) (xy 182.132281 80.948587) (xy 182.248587 80.832281) (xy 182.339967 80.695521) + (xy 182.402911 80.54356) (xy 182.435 80.38224) (xy 182.435 80.21776) (xy 182.402911 80.05644) (xy 182.339967 79.904479) + (xy 182.248587 79.767719) (xy 182.132281 79.651413) (xy 181.995521 79.560033) (xy 181.84356 79.497089) (xy 181.68224 79.465) + (xy 181.51776 79.465) (xy 181.410571 79.486321) (xy 181.27625 79.352) (xy 180.127 79.352) (xy 180.127 79.372) + (xy 180.06 79.372) (xy 180.06 79.078) (xy 180.127 79.078) (xy 180.127 79.098) (xy 181.27625 79.098) + (xy 181.435 78.93925) (xy 181.438072 78.725) (xy 181.425812 78.600518) (xy 181.389502 78.48082) (xy 181.330537 78.370506) + (xy 181.251185 78.273815) (xy 181.154494 78.194463) (xy 181.04418 78.135498) (xy 180.924482 78.099188) (xy 180.8 78.086928) + (xy 180.28575 78.09) (xy 180.127002 78.248748) (xy 180.127002 78.09) (xy 180.06 78.09) (xy 180.06 77.984877) + (xy 180.063435 77.95) (xy 180.049727 77.810816) (xy 180.009128 77.67698) (xy 179.9432 77.553637) (xy 179.854475 77.445525) + (xy 179.746363 77.3568) (xy 179.62302 77.290872) (xy 179.489184 77.250273) (xy 179.384877 77.24) (xy 179.35 77.236565) + (xy 179.315123 77.24) (xy 175.884877 77.24) (xy 175.85 77.236565) (xy 175.815123 77.24) (xy 175.710816 77.250273) + (xy 175.57698 77.290872) (xy 175.453637 77.3568) (xy 175.345525 77.445525) (xy 175.2568 77.553637) (xy 175.190872 77.67698) + (xy 175.150273 77.810816) (xy 175.136565 77.95) (xy 175.140001 77.984887) (xy 175.140001 78.086928) (xy 174.4 78.086928) + (xy 174.275518 78.099188) (xy 174.15582 78.135498) (xy 174.045506 78.194463) (xy 173.948815 78.273815) (xy 173.869463 78.370506) + (xy 173.810498 78.48082) (xy 173.806686 78.493387) (xy 173.720753 78.519454) (xy 173.588724 78.590026) (xy 173.472999 78.684999) + (xy 173.4492 78.713998) (xy 172.989002 79.174197) (xy 172.959999 79.197999) (xy 172.916164 79.251413) (xy 172.865026 79.313724) + (xy 172.80849 79.419494) (xy 172.794454 79.445754) (xy 172.750997 79.589015) (xy 172.74 79.700668) (xy 172.74 79.700678) + (xy 172.736324 79.738) (xy 172.74 79.775322) (xy 172.74 80.002841) (xy 172.697089 80.106438) (xy 172.665 80.267758) + (xy 172.665 80.432238) (xy 172.673412 80.474526) (xy 172.605941 80.510589) (xy 172.471183 80.621183) (xy 172.360589 80.755941) + (xy 172.278411 80.909687) (xy 172.269919 80.937681) (xy 172.148986 80.900997) (xy 172.037333 80.89) (xy 172.037322 80.89) + (xy 172 80.886324) (xy 171.962678 80.89) (xy 170.827238 80.89) (xy 170.825812 80.875518) (xy 170.789502 80.75582) + (xy 170.730537 80.645506) (xy 170.651185 80.548815) (xy 170.554494 80.469463) (xy 170.44418 80.410498) (xy 170.324482 80.374188) + (xy 170.2 80.361928) (xy 169.25 80.361928) (xy 169.125518 80.374188) (xy 169.00582 80.410498) (xy 168.895506 80.469463) + (xy 168.798815 80.548815) (xy 168.719463 80.645506) (xy 168.660498 80.75582) (xy 168.624188 80.875518) (xy 168.611928 81) + (xy 168.611928 82.3) (xy 168.624188 82.424482) (xy 168.660498 82.54418) (xy 168.719463 82.654494) (xy 168.798815 82.751185) + (xy 168.895506 82.830537) (xy 169.00582 82.889502) (xy 169.125518 82.925812) (xy 169.25 82.938072) (xy 170.2 82.938072) + (xy 170.324482 82.925812) (xy 170.44418 82.889502) (xy 170.554494 82.830537) (xy 170.651185 82.751185) (xy 170.730537 82.654494) + (xy 170.789502 82.54418) (xy 170.825812 82.424482) (xy 170.827238 82.41) (xy 171.685199 82.41) (xy 172.6862 83.411002) + (xy 172.709999 83.440001) (xy 172.738997 83.463799) (xy 172.825723 83.534974) (xy 172.914151 83.58224) (xy 172.957753 83.605546) + (xy 173.101014 83.649003) (xy 173.212667 83.66) (xy 173.212677 83.66) (xy 173.25 83.663676) (xy 173.287323 83.66) + (xy 174.445386 83.66) (xy 174.447089 83.66856) (xy 174.510033 83.820521) (xy 174.601413 83.957281) (xy 174.717719 84.073587) + (xy 174.854479 84.164967) (xy 175.00644 84.227911) (xy 175.16776 84.26) (xy 175.266136 84.26) (xy 175.220583 84.328175) + (xy 175.018183 84.816814) (xy 174.915 85.335551) (xy 174.915 85.864449) (xy 175.018183 86.383186) (xy 175.023749 86.396623) + (xy 174.801302 86.247989) (xy 174.492012 86.119877) (xy 174.527932 86.033158) (xy 174.585 85.74626) (xy 174.585 85.45374) + (xy 174.527932 85.166842) (xy 174.41599 84.896589) (xy 174.253475 84.653368) (xy 174.046632 84.446525) (xy 173.803411 84.28401) + (xy 173.533158 84.172068) (xy 173.24626 84.115) (xy 173.076697 84.115) (xy 172.982327 84.075911) (xy 172.676109 84.015) + (xy 172.363891 84.015) (xy 172.057673 84.075911) (xy 171.769221 84.195391) (xy 171.509621 84.36885) (xy 171.28885 84.589621) + (xy 171.115391 84.849221) (xy 170.995911 85.137673) (xy 170.935 85.443891) (xy 170.935 85.756109) (xy 170.995911 86.062327) + (xy 171.115391 86.350779) (xy 171.28885 86.610379) (xy 171.509621 86.83115) (xy 171.769221 87.004609) (xy 171.935016 87.073283) + (xy 171.897988 87.128699) (xy 171.737047 87.517245) (xy 171.655 87.929722) (xy 171.655 88.35028) (xy 171.737047 88.762757) + (xy 171.869252 89.081928) (xy 170.75 89.081928) (xy 170.625518 89.094188) (xy 170.50582 89.130498) (xy 170.395506 89.189463) + (xy 170.336818 89.237627) (xy 170.295521 89.210033) (xy 170.14356 89.147089) (xy 169.98224 89.115) (xy 169.81776 89.115) + (xy 169.65644 89.147089) (xy 169.504479 89.210033) (xy 169.367719 89.301413) (xy 169.251413 89.417719) (xy 169.160033 89.554479) + (xy 169.097089 89.70644) (xy 169.065 89.86776) (xy 169.065 90.03224) (xy 169.097089 90.19356) (xy 169.140001 90.297159) + (xy 169.14 92.712679) (xy 169.136324 92.750002) (xy 169.14 92.787324) (xy 169.14 92.787334) (xy 169.149912 92.887967) + (xy 169.145521 92.885033) (xy 168.99356 92.822089) (xy 168.83224 92.79) (xy 168.66776 92.79) (xy 168.50644 92.822089) + (xy 168.402843 92.865) (xy 166.599802 92.865) (xy 165.249801 91.515) (xy 166.011003 90.753799) (xy 166.040001 90.730001) + (xy 166.134974 90.614276) (xy 166.205546 90.482247) (xy 166.249003 90.338986) (xy 166.26 90.227333) (xy 166.26 90.227325) + (xy 166.263676 90.19) (xy 166.26 90.152675) (xy 166.26 87.408072) (xy 166.440001 87.408072) (xy 166.440001 91.758477) + (xy 166.452806 91.88849) (xy 166.503412 92.055313) (xy 166.58559 92.209059) (xy 166.696184 92.343817) (xy 166.830942 92.454411) + (xy 166.984688 92.536589) (xy 167.151511 92.587195) (xy 167.325 92.604282) (xy 167.49849 92.587195) (xy 167.665313 92.536589) + (xy 167.819059 92.454411) (xy 167.953817 92.343817) (xy 168.064411 92.209059) (xy 168.146589 92.055313) (xy 168.197195 91.88849) + (xy 168.21 91.758477) (xy 168.21 84.55) (xy 168.611928 84.55) (xy 168.611928 85.85) (xy 168.624188 85.974482) + (xy 168.660498 86.09418) (xy 168.719463 86.204494) (xy 168.798815 86.301185) (xy 168.895506 86.380537) (xy 168.946789 86.407949) + (xy 168.915 86.56776) (xy 168.915 86.73224) (xy 168.947089 86.89356) (xy 169.010033 87.045521) (xy 169.101413 87.182281) + (xy 169.217719 87.298587) (xy 169.354479 87.389967) (xy 169.50644 87.452911) (xy 169.66776 87.485) (xy 169.83224 87.485) + (xy 169.99356 87.452911) (xy 170.145521 87.389967) (xy 170.282281 87.298587) (xy 170.398587 87.182281) (xy 170.489967 87.045521) + (xy 170.552911 86.89356) (xy 170.585 86.73224) (xy 170.585 86.56776) (xy 170.552911 86.40644) (xy 170.544414 86.385925) + (xy 170.554494 86.380537) (xy 170.651185 86.301185) (xy 170.730537 86.204494) (xy 170.789502 86.09418) (xy 170.825812 85.974482) + (xy 170.838072 85.85) (xy 170.838072 84.55) (xy 170.825812 84.425518) (xy 170.789502 84.30582) (xy 170.730537 84.195506) + (xy 170.651185 84.098815) (xy 170.554494 84.019463) (xy 170.44418 83.960498) (xy 170.324482 83.924188) (xy 170.2 83.911928) + (xy 169.25 83.911928) (xy 169.125518 83.924188) (xy 169.00582 83.960498) (xy 168.895506 84.019463) (xy 168.798815 84.098815) + (xy 168.719463 84.195506) (xy 168.660498 84.30582) (xy 168.624188 84.425518) (xy 168.611928 84.55) (xy 168.21 84.55) + (xy 168.21 78.158466) (xy 168.214281 78.114999) (xy 168.21 78.071533) (xy 168.21 78.071523) (xy 168.197195 77.94151) + (xy 168.146589 77.774687) (xy 168.135 77.753005) (xy 168.135 65.463078) (xy 168.386928 65.21115) (xy 168.386928 66.075) + (xy 168.399188 66.199482) (xy 168.435498 66.31918) (xy 168.494463 66.429494) (xy 168.573815 66.526185) (xy 168.670506 66.605537) + (xy 168.78082 66.664502) (xy 168.900518 66.700812) (xy 169.025 66.713072) (xy 169.708204 66.713072) (xy 169.747533 66.808021) + (xy 169.838913 66.944781) (xy 169.955219 67.061087) (xy 170.091979 67.152467) (xy 170.24394 67.215411) (xy 170.40526 67.2475) + (xy 170.56974 67.2475) (xy 170.73106 67.215411) (xy 170.883021 67.152467) (xy 171.019781 67.061087) (xy 171.031828 67.04904) + (xy 171.115391 67.250779) (xy 171.28885 67.510379) (xy 171.509621 67.73115) (xy 171.769221 67.904609) (xy 171.935016 67.973283) + (xy 171.897988 68.028699) (xy 171.737047 68.417245) (xy 171.655 68.829722) (xy 171.655 69.25028) (xy 171.737047 69.662757) + (xy 171.869252 69.981928) (xy 170.75 69.981928) (xy 170.625518 69.994188) (xy 170.50582 70.030498) (xy 170.395506 70.089463) + (xy 170.336818 70.137627) (xy 170.295521 70.110033) (xy 170.14356 70.047089) (xy 169.98224 70.015) (xy 169.81776 70.015) + (xy 169.65644 70.047089) (xy 169.504479 70.110033) (xy 169.367719 70.201413) (xy 169.251413 70.317719) (xy 169.160033 70.454479) + (xy 169.097089 70.60644) (xy 169.065 70.76776) (xy 169.065 70.93224) (xy 169.097089 71.09356) (xy 169.140001 71.197159) + (xy 169.14 73.612679) (xy 169.136324 73.650002) (xy 169.14 73.687324) (xy 169.14 73.687334) (xy 169.150997 73.798987) + (xy 169.182907 73.904181) (xy 169.194454 73.942248) (xy 169.265026 74.074278) (xy 169.297792 74.114203) (xy 169.359999 74.190003) + (xy 169.389002 74.213805) (xy 170.061204 74.886009) (xy 170.084998 74.915002) (xy 170.113991 74.938796) (xy 170.113995 74.9388) + (xy 170.170259 74.984974) (xy 170.200723 75.009975) (xy 170.332752 75.080547) (xy 170.476013 75.124004) (xy 170.587666 75.135001) + (xy 170.587675 75.135001) (xy 170.624998 75.138677) (xy 170.662321 75.135001) (xy 183.587677 75.135001) (xy 183.624999 75.138677) + (xy 183.662321 75.135001) (xy 183.662332 75.135001) (xy 183.773985 75.124004) (xy 183.917246 75.080547) (xy 184.049275 75.009975) + (xy 184.165 74.915002) (xy 184.188803 74.885999) (xy 185.111003 73.963799) (xy 185.140001 73.940001) (xy 185.234974 73.824276) + (xy 185.305546 73.692247) (xy 185.349003 73.548986) (xy 185.36 73.437333) (xy 185.36 73.437325) (xy 185.363676 73.4) + (xy 185.36 73.362675) (xy 185.36 70.718072) (xy 185.75 70.718072) (xy 185.874482 70.705812) (xy 185.99418 70.669502) + (xy 186.104494 70.610537) (xy 186.201185 70.531185) (xy 186.280537 70.434494) (xy 186.339502 70.32418) (xy 186.375812 70.204482) + (xy 186.388072 70.08) (xy 186.388072 68.08) (xy 186.375812 67.955518) (xy 186.339502 67.83582) (xy 186.280537 67.725506) + (xy 186.201185 67.628815) (xy 186.104494 67.549463) (xy 185.99418 67.490498) (xy 185.874482 67.454188) (xy 185.75 67.441928) + (xy 183.956887 67.441928) (xy 184.084609 67.250779) (xy 184.204089 66.962327) (xy 184.265 66.656109) (xy 184.265 66.343891) + (xy 184.204089 66.037673) (xy 184.084609 65.749221) (xy 183.91115 65.489621) (xy 183.876199 65.45467) (xy 183.898587 65.432281) + (xy 183.989967 65.295521) (xy 184.052911 65.14356) (xy 184.085 64.98224) (xy 184.085 64.81776) (xy 184.052911 64.65644) + (xy 183.989967 64.504479) (xy 183.898587 64.367719) (xy 183.782281 64.251413) (xy 183.710011 64.203124) (xy 183.710011 61.47883) + (xy 183.752922 61.375233) (xy 183.785011 61.213913) (xy 183.785011 61.049433) (xy 183.752922 60.888113) (xy 183.689978 60.736152) + (xy 183.598598 60.599392) (xy 183.482292 60.483086) (xy 183.345532 60.391706) (xy 183.193571 60.328762) (xy 183.032251 60.296673) + (xy 182.867771 60.296673) (xy 182.706451 60.328762) (xy 182.55449 60.391706) (xy 182.41773 60.483086) (xy 182.301424 60.599392) + (xy 182.260586 60.66051) (xy 182.198585 60.567719) (xy 182.082279 60.451413) (xy 181.945519 60.360033) (xy 181.793558 60.297089) + (xy 181.632238 60.265) (xy 181.467758 60.265) (xy 181.318867 60.294617) (xy 181.27625 60.252) (xy 180.127 60.252) + (xy 180.127 60.272) (xy 180.06 60.272) (xy 180.06 59.978) (xy 180.127 59.978) (xy 180.127 59.998) + (xy 181.27625 59.998) (xy 181.435 59.83925) (xy 181.438072 59.625) (xy 181.425812 59.500518) (xy 181.389502 59.38082) + (xy 181.330537 59.270506) (xy 181.251185 59.173815) (xy 181.154494 59.094463) (xy 181.04418 59.035498) (xy 180.924482 58.999188) + (xy 180.8 58.986928) (xy 180.28575 58.99) (xy 180.127002 59.148748) (xy 180.127002 58.99) (xy 180.06 58.99) + (xy 180.06 58.783277) (xy 180.063435 58.7484) (xy 180.049727 58.609216) (xy 180.009128 58.47538) (xy 179.9432 58.352037) + (xy 179.854475 58.243925) (xy 179.746363 58.1552) (xy 179.62302 58.089272) (xy 179.489184 58.048673) (xy 179.384877 58.0384) + (xy 179.35 58.034965) (xy 179.315123 58.0384) (xy 175.884877 58.0384) (xy 175.85 58.034965) (xy 175.815123 58.0384) + (xy 175.710816 58.048673) (xy 175.57698 58.089272) (xy 175.453637 58.1552) (xy 175.345525 58.243925) (xy 175.2568 58.352037) + (xy 175.190872 58.47538) (xy 175.150273 58.609216) (xy 175.136565 58.7484) (xy 175.140001 58.783287) (xy 175.140001 58.986928) + (xy 174.4 58.986928) (xy 174.275518 58.999188) (xy 174.15582 59.035498) (xy 174.045506 59.094463) (xy 173.948815 59.173815) + (xy 173.869463 59.270506) (xy 173.810498 59.38082) (xy 173.774188 59.500518) (xy 173.761928 59.625) (xy 173.761928 59.91327) + (xy 173.322722 60.352476) (xy 173.304479 60.360033) (xy 173.167719 60.451413) (xy 173.051413 60.567719) (xy 172.960033 60.704479) + (xy 172.897089 60.85644) (xy 172.870522 60.99) (xy 172.310001 60.99) (xy 172.310001 60.47047) (xy 172.314282 60.427001) + (xy 172.310001 60.383532) (xy 172.310001 60.383524) (xy 172.297196 60.253511) (xy 172.24659 60.086688) (xy 172.164412 59.932942) + (xy 172.122145 59.88144) (xy 172.081533 59.831954) (xy 172.081531 59.831952) (xy 172.053818 59.798184) (xy 172.020051 59.770472) + (xy 168.635 56.385422) (xy 168.635 53.833477) (xy 168.639282 53.79) (xy 168.635 53.746523) (xy 168.635 48.471105) + (xy 168.650518 48.475812) (xy 168.775 48.488072) (xy 169.725 48.488072) (xy 169.849482 48.475812) (xy 169.934399 48.450053) + (xy 169.934399 51.015) (xy 169.81776 51.015) (xy 169.65644 51.047089) (xy 169.504479 51.110033) (xy 169.367719 51.201413) + (xy 169.251413 51.317719) (xy 169.160033 51.454479) (xy 169.097089 51.60644) (xy 169.065 51.76776) (xy 169.065 51.93224) + (xy 169.097089 52.09356) (xy 169.140001 52.197159) (xy 169.14 54.612679) (xy 169.136324 54.650002) (xy 169.14 54.687324) + (xy 169.14 54.687334) (xy 169.150997 54.798987) (xy 169.184976 54.911003) (xy 169.194454 54.942248) (xy 169.265026 55.074278) + (xy 169.304871 55.122828) (xy 169.359999 55.190003) (xy 169.389002 55.213805) (xy 170.061204 55.886009) (xy 170.084998 55.915002) + (xy 170.113991 55.938796) (xy 170.113995 55.9388) (xy 170.175729 55.989463) (xy 170.200723 56.009975) (xy 170.332752 56.080547) + (xy 170.476013 56.124004) (xy 170.587666 56.135001) (xy 170.587675 56.135001) (xy 170.624998 56.138677) (xy 170.662321 56.135001) + (xy 183.587677 56.135001) (xy 183.624999 56.138677) (xy 183.662321 56.135001) (xy 183.662332 56.135001) (xy 183.773985 56.124004) + (xy 183.917246 56.080547) (xy 184.049275 56.009975) (xy 184.165 55.915002) (xy 184.188803 55.885999) (xy 185.111004 54.963798) + (xy 185.140001 54.940001) (xy 185.234974 54.824276) (xy 185.305546 54.692247) (xy 185.349003 54.548986) (xy 185.36 54.437333) + (xy 185.36 54.437325) (xy 185.363676 54.4) (xy 185.36 54.362675) (xy 185.36 51.718072) (xy 185.75 51.718072) + (xy 185.874482 51.705812) (xy 185.99418 51.669502) (xy 186.104494 51.610537) (xy 186.201185 51.531185) (xy 186.280537 51.434494) + (xy 186.339502 51.32418) (xy 186.375812 51.204482) (xy 186.388072 51.08) (xy 186.388072 49.08) (xy 186.375812 48.955518) + (xy 186.339502 48.83582) (xy 186.280537 48.725506) (xy 186.201185 48.628815) (xy 186.104494 48.549463) (xy 185.99418 48.490498) + (xy 185.874482 48.454188) (xy 185.75 48.441928) (xy 183.956887 48.441928) (xy 184.084609 48.250779) (xy 184.204089 47.962327) + (xy 184.265 47.656109) (xy 184.265 47.343891) (xy 184.204089 47.037673) (xy 184.084609 46.749221) (xy 183.91115 46.489621) + (xy 183.690379 46.26885) (xy 183.430779 46.095391) (xy 183.142327 45.975911) (xy 182.836109 45.915) (xy 182.523891 45.915) + (xy 182.217673 45.975911) (xy 182.123303 46.015) (xy 181.95374 46.015) (xy 181.666842 46.072068) (xy 181.396589 46.18401) + (xy 181.153368 46.346525) (xy 180.946525 46.553368) (xy 180.78401 46.796589) (xy 180.672068 47.066842) (xy 180.615 47.35374) + (xy 180.615 47.64626) (xy 180.672068 47.933158) (xy 180.707988 48.019876) (xy 180.398698 48.147988) (xy 180.176252 48.296622) + (xy 180.181817 48.283186) (xy 180.285 47.764449) (xy 180.285 47.235551) (xy 180.181817 46.716814) (xy 179.979417 46.228175) + (xy 179.685576 45.788412) (xy 179.657164 45.76) (xy 179.812677 45.76) (xy 179.849999 45.763676) (xy 179.887321 45.76) + (xy 179.887332 45.76) (xy 179.998985 45.749003) (xy 180.142246 45.705546) (xy 180.274275 45.634974) (xy 180.39 45.540001) + (xy 180.413803 45.510997) (xy 180.541922 45.382878) (xy 180.645521 45.339966) (xy 180.782281 45.248586) (xy 180.898587 45.13228) + (xy 180.989967 44.99552) (xy 181.052911 44.843559) (xy 181.085 44.682239) (xy 181.085 44.517759) (xy 181.052911 44.356439) + (xy 181.01 44.252842) (xy 181.01 43.97487) (xy 181.04418 43.964502) (xy 181.154494 43.905537) (xy 181.251185 43.826185) + (xy 181.330537 43.729494) (xy 181.389502 43.61918) (xy 181.425812 43.499482) (xy 181.438072 43.375) (xy 181.438072 42.375) + (xy 181.425812 42.250518) (xy 181.389502 42.13082) (xy 181.330537 42.020506) (xy 181.313708 42) (xy 181.330537 41.979494) + (xy 181.389502 41.86918) (xy 181.425812 41.749482) (xy 181.438072 41.625) (xy 181.435 41.41075) (xy 181.27625 41.252) + (xy 180.127 41.252) (xy 180.127 41.272) (xy 180.06 41.272) (xy 180.06 40.978) (xy 180.127 40.978) + (xy 180.127 40.998) (xy 181.27625 40.998) (xy 181.435 40.83925) (xy 181.436495 40.735) (xy 181.58224 40.735) + (xy 181.74356 40.702911) (xy 181.895521 40.639967) (xy 182.032281 40.548587) (xy 182.148587 40.432281) (xy 182.239967 40.295521) + (xy 182.302911 40.14356) (xy 182.335 39.98224) (xy 182.335 39.81776) (xy 182.302911 39.65644) (xy 182.239967 39.504479) + (xy 182.148587 39.367719) (xy 182.032281 39.251413) (xy 181.895521 39.160033) (xy 181.791922 39.117121) (xy 181.634801 38.96) + (xy 188.535199 38.96) ) ) (filled_polygon @@ -15284,26 +15290,23 @@ (xy 99.920006 126.2258) (xy 99.919995 126.2258) (xy 99.882673 126.222124) (xy 99.845351 126.2258) (xy 98.856357 126.2258) (xy 98.75276 126.182889) (xy 98.59144 126.1508) (xy 98.42696 126.1508) (xy 98.26564 126.182889) (xy 98.113679 126.245833) (xy 97.976919 126.337213) (xy 97.860613 126.453519) (xy 97.769233 126.590279) (xy 97.706289 126.74224) (xy 97.6742 126.90356) - (xy 97.6742 127.06804) (xy 97.706289 127.22936) (xy 97.769233 127.381321) (xy 97.860613 127.518081) (xy 97.953124 127.610592) - (xy 97.894454 127.720353) (xy 97.850997 127.863614) (xy 97.84 127.975267) (xy 97.84 127.975278) (xy 97.836324 128.0126) - (xy 97.84 128.049922) (xy 97.84 128.05635) (xy 97.836324 128.093672) (xy 97.84 128.130994) (xy 97.84 128.131004) - (xy 97.850997 128.242657) (xy 97.879174 128.335546) (xy 97.894454 128.385918) (xy 97.965026 128.517948) (xy 97.998154 128.558314) - (xy 98.048775 128.619996) (xy 98.049741 128.649504) (xy 98.078144 128.771321) (xy 98.129768 128.885255) (xy 98.509144 129.542354) - (xy 98.294489 129.666285) (xy 98.262569 129.680748) (xy 98.234084 129.70116) (xy 98.234082 129.701161) (xy 98.148886 129.762211) - (xy 98.05328 129.864289) (xy 97.979426 129.983056) (xy 97.930161 130.11395) (xy 97.907379 130.25194) (xy 97.911955 130.391721) - (xy 97.943713 130.527926) (xy 98.001434 130.655317) (xy 98.021847 130.683803) (xy 98.363544 131.27564) (xy 97.981825 131.020583) - (xy 97.493186 130.818183) (xy 96.974449 130.715) (xy 96.445551 130.715) (xy 95.926814 130.818183) (xy 95.438175 131.020583) - (xy 94.998412 131.314424) (xy 94.740295 131.572541) (xy 94.740295 131.160165) (xy 94.702229 130.968796) (xy 94.893158 130.930818) - (xy 95.163411 130.818876) (xy 95.406632 130.656361) (xy 95.613475 130.449518) (xy 95.77599 130.206297) (xy 95.887932 129.936044) - (xy 95.945 129.649146) (xy 95.945 129.356626) (xy 95.887932 129.069728) (xy 95.77599 128.799475) (xy 95.733355 128.735668) - (xy 95.694089 128.538264) (xy 95.574609 128.249812) (xy 95.40115 127.990212) (xy 95.180379 127.769441) (xy 94.920779 127.595982) - (xy 94.632327 127.476502) (xy 94.326109 127.415591) (xy 94.108815 127.415591) (xy 97.736928 123.787478) (xy 97.736928 124.075) - (xy 97.749188 124.199482) (xy 97.785498 124.31918) (xy 97.844463 124.429494) (xy 97.923815 124.526185) (xy 98.020506 124.605537) - (xy 98.13082 124.664502) (xy 98.250518 124.700812) (xy 98.375 124.713072) (xy 99.675 124.713072) (xy 99.799482 124.700812) - (xy 99.91918 124.664502) (xy 100.029494 124.605537) (xy 100.126185 124.526185) (xy 100.205537 124.429494) (xy 100.264502 124.31918) - (xy 100.300812 124.199482) (xy 100.313072 124.075) (xy 100.313072 123.56173) (xy 100.491923 123.382878) (xy 100.595521 123.339967) - (xy 100.732281 123.248587) (xy 100.848587 123.132281) (xy 100.939967 122.995521) (xy 101.002911 122.84356) (xy 101.035 122.68224) - (xy 101.035 122.584799) (xy 101.588586 122.584799) + (xy 97.6742 127.06804) (xy 97.706289 127.22936) (xy 97.769233 127.381321) (xy 97.860613 127.518081) (xy 97.976919 127.634387) + (xy 98.0814 127.704199) (xy 98.0814 128.360221) (xy 98.066024 128.401074) (xy 98.045648 128.524487) (xy 98.049741 128.649504) + (xy 98.078144 128.771321) (xy 98.129768 128.885255) (xy 98.509144 129.542354) (xy 98.294489 129.666285) (xy 98.262569 129.680748) + (xy 98.234084 129.70116) (xy 98.234082 129.701161) (xy 98.148886 129.762211) (xy 98.05328 129.864289) (xy 97.979426 129.983056) + (xy 97.930161 130.11395) (xy 97.907379 130.25194) (xy 97.911955 130.391721) (xy 97.943713 130.527926) (xy 98.001434 130.655317) + (xy 98.021847 130.683803) (xy 98.363544 131.27564) (xy 97.981825 131.020583) (xy 97.493186 130.818183) (xy 96.974449 130.715) + (xy 96.445551 130.715) (xy 95.926814 130.818183) (xy 95.438175 131.020583) (xy 94.998412 131.314424) (xy 94.740295 131.572541) + (xy 94.740295 131.160165) (xy 94.702229 130.968796) (xy 94.893158 130.930818) (xy 95.163411 130.818876) (xy 95.406632 130.656361) + (xy 95.613475 130.449518) (xy 95.77599 130.206297) (xy 95.887932 129.936044) (xy 95.945 129.649146) (xy 95.945 129.356626) + (xy 95.887932 129.069728) (xy 95.77599 128.799475) (xy 95.733355 128.735668) (xy 95.694089 128.538264) (xy 95.574609 128.249812) + (xy 95.40115 127.990212) (xy 95.180379 127.769441) (xy 94.920779 127.595982) (xy 94.632327 127.476502) (xy 94.326109 127.415591) + (xy 94.108815 127.415591) (xy 97.736928 123.787478) (xy 97.736928 124.075) (xy 97.749188 124.199482) (xy 97.785498 124.31918) + (xy 97.844463 124.429494) (xy 97.923815 124.526185) (xy 98.020506 124.605537) (xy 98.13082 124.664502) (xy 98.250518 124.700812) + (xy 98.375 124.713072) (xy 99.675 124.713072) (xy 99.799482 124.700812) (xy 99.91918 124.664502) (xy 100.029494 124.605537) + (xy 100.126185 124.526185) (xy 100.205537 124.429494) (xy 100.264502 124.31918) (xy 100.300812 124.199482) (xy 100.313072 124.075) + (xy 100.313072 123.56173) (xy 100.491923 123.382878) (xy 100.595521 123.339967) (xy 100.732281 123.248587) (xy 100.848587 123.132281) + (xy 100.939967 122.995521) (xy 101.002911 122.84356) (xy 101.035 122.68224) (xy 101.035 122.584799) (xy 101.588586 122.584799) ) ) (filled_polygon @@ -15348,8 +15351,8 @@ (xy 107.645306 121.630337) (xy 107.75562 121.689302) (xy 107.875318 121.725612) (xy 107.9998 121.737872) (xy 109.2998 121.737872) (xy 109.424282 121.725612) (xy 109.54398 121.689302) (xy 109.654294 121.630337) (xy 109.699999 121.592828) (xy 109.699998 122.222062) (xy 109.695506 122.224463) (xy 109.598815 122.303815) (xy 109.519463 122.400506) (xy 109.460498 122.51082) (xy 109.424188 122.630518) - (xy 109.411928 122.755) (xy 109.411928 123.030002) (xy 109.108077 123.333853) (xy 109.004479 123.376765) (xy 108.867719 123.468145) - (xy 108.839569 123.496295) (xy 108.68224 123.465) (xy 108.51776 123.465) (xy 108.35644 123.497089) (xy 108.275051 123.530801) + (xy 109.411928 122.755) (xy 109.411928 123.030002) (xy 109.108077 123.333853) (xy 109.004479 123.376765) (xy 108.879818 123.46006) + (xy 108.77349 123.427805) (xy 108.6 123.410719) (xy 108.42651 123.427805) (xy 108.259687 123.478412) (xy 108.235559 123.491309) (xy 108.12625 123.382) (xy 106.777 123.382) (xy 106.777 123.402) (xy 106.523 123.402) (xy 106.523 123.382) (xy 106.503 123.382) (xy 106.503 123.128) (xy 106.523 123.128) (xy 106.523 122.27875) (xy 106.777 122.27875) (xy 106.777 123.128) (xy 108.12625 123.128) (xy 108.285 122.96925) (xy 108.288072 122.755) (xy 108.275812 122.630518) @@ -15486,14 +15489,14 @@ ) (filled_polygon (pts - (xy 142.027 98.198) (xy 142.047 98.198) (xy 142.047 98.452) (xy 142.027 98.452) (xy 142.027 98.472) - (xy 141.96 98.472) (xy 141.96 98.178) (xy 142.027 98.178) + (xy 180.127 98.198) (xy 180.147 98.198) (xy 180.147 98.452) (xy 180.127 98.452) (xy 180.127 98.472) + (xy 180.06 98.472) (xy 180.06 98.178) (xy 180.127 98.178) ) ) (filled_polygon (pts - (xy 180.127 98.198) (xy 180.147 98.198) (xy 180.147 98.452) (xy 180.127 98.452) (xy 180.127 98.472) - (xy 180.06 98.472) (xy 180.06 98.178) (xy 180.127 98.178) + (xy 142.027 98.198) (xy 142.047 98.198) (xy 142.047 98.452) (xy 142.027 98.452) (xy 142.027 98.472) + (xy 141.96 98.472) (xy 141.96 98.178) (xy 142.027 98.178) ) ) (filled_polygon @@ -15939,14 +15942,14 @@ ) (filled_polygon (pts - (xy 218.227 83.998) (xy 218.247 83.998) (xy 218.247 84.252) (xy 218.227 84.252) (xy 218.227 84.272) - (xy 218.16 84.272) (xy 218.16 83.978) (xy 218.227 83.978) + (xy 199.227 83.998) (xy 199.247 83.998) (xy 199.247 84.252) (xy 199.227 84.252) (xy 199.227 84.272) + (xy 199.16 84.272) (xy 199.16 83.978) (xy 199.227 83.978) ) ) (filled_polygon (pts - (xy 199.227 83.998) (xy 199.247 83.998) (xy 199.247 84.252) (xy 199.227 84.252) (xy 199.227 84.272) - (xy 199.16 84.272) (xy 199.16 83.978) (xy 199.227 83.978) + (xy 218.227 83.998) (xy 218.247 83.998) (xy 218.247 84.252) (xy 218.227 84.252) (xy 218.227 84.272) + (xy 218.16 84.272) (xy 218.16 83.978) (xy 218.227 83.978) ) ) (filled_polygon diff --git a/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak index 200eaf3f..cf46c6f4 100644 --- a/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak +++ b/Sofle_RGB_v3/PCB/SofleKeyboard.kicad_pcb-bak @@ -308,6720 +308,6720 @@ (add_net VCC) ) - (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FD12) (tstamp 61CC20B4) - (at 185.4454 99.3394 270) - (path /5B911E74) - (attr smd) - (fp_text reference JP9 (at -2.286 0.127 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9724D) + (at 128.75 45.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7226E7) + (autoplace_cost180 10) + (fp_text reference D1 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 94 BL) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 64 lights) (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 1 "Net-(D1-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 1 "Net-(D1-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) ) - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9E1) - (at 108.85 124.13) - (path /5F7EC8B3) - (fp_text reference D34 (at 0.95 -0.735) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9725A) + (at 131 45.7805 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722847) + (autoplace_cost180 10) + (fp_text reference D2 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 59 "Net-(D31-Pad1)")) - (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 62 "Net-(D34-Pad1)")) - (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 59 "Net-(D31-Pad1)")) - (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 62 "Net-(D34-Pad1)")) - (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - ) - - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C999) - (at 120.5 59.5 180) - (path /5F7E6561) - (fp_text reference D31 (at -4.94 -0.76) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 3 "Net-(D2-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 3 "Net-(D2-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 60 "Net-(D31-Pad3)")) - (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 59 "Net-(D31-Pad1)")) - (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 60 "Net-(D31-Pad3)")) - (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 59 "Net-(D31-Pad1)")) - (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) ) - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9B1) - (at 158.5 53.79) - (path /5F7E9258) - (fp_text reference D32 (at -5.21 -1.04) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97267) + (at 150.5 43.04 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722950) + (autoplace_cost180 10) + (fp_text reference D3 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 4 "Net-(D3-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 4 "Net-(D3-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 61 "Net-(D32-Pad3)")) - (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 60 "Net-(D31-Pad3)")) - (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 61 "Net-(D32-Pad3)")) - (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 60 "Net-(D31-Pad3)")) - (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) ) - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9C9) - (at 197.5 61.25 180) - (path /5F7EC8AD) - (fp_text reference D33 (at -4.84 1.41) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97274) + (at 169.25 45.425 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722A8F) + (autoplace_cost180 10) + (fp_text reference D4 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 6 "Net-(D4-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 6 "Net-(D4-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 64 lights)) - (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 61 "Net-(D32-Pad3)")) - (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 64 lights)) - (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 61 "Net-(D32-Pad3)")) - (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) ) - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9F9) - (at 149.0836 118.2626) - (path /5F7EF5F2) - (fp_text reference D35 (at 0.88 -0.76) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97281) + (at 188 50.25 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722BAD) + (autoplace_cost180 10) + (fp_text reference D5 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 8 "Net-(D5-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 8 "Net-(D5-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 62 "Net-(D34-Pad1)")) - (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 63 "Net-(D35-Pad1)")) - (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 62 "Net-(D34-Pad1)")) - (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 63 "Net-(D35-Pad1)")) - (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) ) - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA11) - (at 185.05 120.32) - (path /5F7EF5F8) - (fp_text reference D36 (at 0.87 -0.62) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9728E) + (at 207.75 50.025 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B722FE1) + (autoplace_cost180 10) + (fp_text reference D6 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 10 "Net-(D6-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 5 row0)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 10 "Net-(D6-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 63 "Net-(D35-Pad1)")) - (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 94 BL)) - (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 63 "Net-(D35-Pad1)")) - (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 94 BL)) - (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) ) - (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA29) - (at 105.75 86.5) - (path /5F918D28) - (fp_text reference D37 (at 0 -2.5) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9729B) + (at 126.8 63.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723D94) + (autoplace_cost180 10) + (fp_text reference D7 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) - (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) - (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 41 LED)) - (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 64 lights)) - (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 41 LED)) - (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 64 lights)) - (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - ) - - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9874A) - (at 215.7 90.5 180) - (path /5F7D0195) - (fp_text reference SW18 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972A8) + (at 129.8 63.8 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723E5F) + (autoplace_cost180 10) + (fp_text reference D8 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 13 "Net-(D8-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 13 "Net-(D8-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 79 "Net-(SW12-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 85 "Net-(SW18-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 79 "Net-(SW12-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 85 "Net-(SW18-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 23 "Net-(D18-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 23 "Net-(D18-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988EE) - (at 215.75 109.5 180) - (path /5F7D0171) - (fp_text reference SW24 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972B5) + (at 150.25 61.065 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B723FA1) + (autoplace_cost180 10) + (fp_text reference D9 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 14 "Net-(D9-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 14 "Net-(D9-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972C2) + (at 169.5 63.65 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7240EA) + (autoplace_cost180 10) + (fp_text reference D10 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 15 "Net-(D10-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 15 "Net-(D10-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 85 "Net-(SW18-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 91 "Net-(SW24-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 85 "Net-(SW18-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 91 "Net-(SW24-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 29 "Net-(D24-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 29 "Net-(D24-Pad2)")) ) - (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FB9E) (tstamp 61CA7193) - (at 112.522 82.804 90) - (path /5B911E74) - (attr smd) - (fp_text reference JP9 (at -2.286 0.127 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972CF) + (at 188.25 66.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72424D) + (autoplace_cost180 10) + (fp_text reference D11 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 41 LED) (clearance 0.1905)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 64 lights) (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 16 "Net-(D11-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 16 "Net-(D11-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988A8) - (at 196.7 109.5 180) - (path /5F7D0177) - (fp_text reference SW23 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972DC) + (at 207.75 67.275 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7243C0) + (autoplace_cost180 10) + (fp_text reference D12 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 180) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3 180) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6 180) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 17 "Net-(D12-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 7 row1)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 17 "Net-(D12-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 90 "Net-(SW23-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 84 "Net-(SW17-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 90 "Net-(SW23-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 84 "Net-(SW17-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 28 "Net-(D23-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 28 "Net-(D23-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5FB24B70) - (at 215.8 52.4 180) - (path /5B722CA9) - (fp_text reference SW6 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972E9) + (at 128.5 83.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7254EE) + (autoplace_cost180 10) + (fp_text reference D13 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 71 "Net-(SW5-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 73 "Net-(SW12-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 71 "Net-(SW5-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 73 "Net-(SW12-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 10 "Net-(D6-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 10 "Net-(D6-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9881C) - (at 158.6 102.19 180) - (path /5F7D0183) - (fp_text reference SW21 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972F6) + (at 131.25 83.675 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7255FF) + (autoplace_cost180 10) + (fp_text reference D14 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 19 "Net-(D14-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 19 "Net-(D14-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 88 "Net-(SW21-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 82 "Net-(SW15-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 88 "Net-(SW21-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 82 "Net-(SW15-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 26 "Net-(D21-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 26 "Net-(D21-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985A6) - (at 215.7 71.3 180) - (path /5B723AD3) - (fp_text reference SW12 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97303) + (at 149.75 81.565 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72571C) + (autoplace_cost180 10) + (fp_text reference D15 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 20 "Net-(D15-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 20 "Net-(D15-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 73 "Net-(SW12-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 79 "Net-(SW12-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 73 "Net-(SW12-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 79 "Net-(SW12-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 17 "Net-(D12-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 17 "Net-(D12-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98560) - (at 196.7 71.3 180) - (path /5B72387D) - (fp_text reference SW11 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97310) + (at 169.725 83.425 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B725841) + (autoplace_cost180 10) + (fp_text reference D16 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 21 "Net-(D16-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 21 "Net-(D16-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 78 "Net-(SW11-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 72 "Net-(SW11-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 78 "Net-(SW11-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 72 "Net-(SW11-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 16 "Net-(D11-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 16 "Net-(D11-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98704) - (at 196.7 90.5 180) - (path /5F7D019B) - (fp_text reference SW17 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9731D) + (at 188.5 88.775 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72596D) + (autoplace_cost180 10) + (fp_text reference D17 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 84 "Net-(SW17-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 78 "Net-(SW11-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 84 "Net-(SW17-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 78 "Net-(SW11-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) (net 22 "Net-(D17-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 22 "Net-(D17-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982EA) - (at 139.5 47.5 180) - (path /5F74DC46) - (fp_text reference SW2 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9732A) + (at 207.75 86.275 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B725AA2) + (autoplace_cost180 10) + (fp_text reference D18 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 23 "Net-(D18-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 9 row2)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 23 "Net-(D18-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 65 "Net-(SW1-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 65 "Net-(SW1-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 3 "Net-(D2-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 3 "Net-(D2-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F7EF4F0) - (at 177.6 123.8 180) - (path /5F7D72C1) - (fp_text reference SW30 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97337) + (at 112 102.75 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B72767A) + (autoplace_cost180 10) + (fp_text reference D19 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97344) + (at 131 103.175 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B7277CE) + (autoplace_cost180 10) + (fp_text reference D20 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 25 "Net-(D20-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 25 "Net-(D20-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 91 "Net-(SW24-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 94 BL)) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 91 "Net-(SW24-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 94 BL)) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 52 "Net-(D30-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 35 col0)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 52 "Net-(D30-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A4C) - (at 158.6 121.29 180) - (path /5F7D72A9) - (fp_text reference SW29 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97351) + (at 150 98.565 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727929) + (autoplace_cost180 10) + (fp_text reference D21 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 26 "Net-(D21-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 26 "Net-(D21-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 93 "Net-(SW28-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 90 "Net-(SW23-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 93 "Net-(SW28-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 90 "Net-(SW23-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 44 "Net-(D29-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 44 "Net-(D29-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A06) - (at 139.5 123.7 180) - (path /5F7D72AF) - (fp_text reference SW28 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9735E) + (at 169.25 102.15 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727A89) + (autoplace_cost180 10) + (fp_text reference D22 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 27 "Net-(D22-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 27 "Net-(D22-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9736B) + (at 188.5 106.75 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727BFE) + (autoplace_cost180 10) + (fp_text reference D23 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 28 "Net-(D23-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 28 "Net-(D23-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 89 "Net-(SW22-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 93 "Net-(SW28-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 89 "Net-(SW22-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 93 "Net-(SW28-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 32 "Net-(D28-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 32 "Net-(D28-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F806503) - (at 117.6 128.4 195) - (path /5F7D72B5) - (fp_text reference SW27 (at 0 3 15 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97378) + (at 208.2 105.175 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B727D79) + (autoplace_cost180 10) + (fp_text reference D24 (at 0.5 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.199999 15) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0 90) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3 15) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 29 "Net-(D24-Pad2)")) + (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 11 row3)) + (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 29 "Net-(D24-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text user D? (at -5.2 6 15) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97385) + (at 107 97) + (descr "Resitance 3 pas") + (tags R) + (path /5B734844) + (autoplace_cost180 10) + (fp_text reference D25 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (pad 2 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 92 "Net-(SW26-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 88 "Net-(SW21-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 92 "Net-(SW26-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 88 "Net-(SW21-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 285) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58 15) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 53 SW25B)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 53 SW25B)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F7EDC95) (tstamp 5BE97392) + (at 100.8 123.6) + (descr "Resitance 3 pas") + (tags R) + (path /5B7349D1) + (autoplace_cost180 10) + (fp_text reference D26 (at 0.7222 -1.1752) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 30 "Net-(D26-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 30 "Net-(D26-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9739F) + (at 110.4248 120.6248) + (descr "Resitance 3 pas") + (tags R) + (path /5B734B62) + (autoplace_cost180 10) + (fp_text reference D27 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) (net 31 "Net-(D27-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12 15) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) (net 31 "Net-(D27-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9897A) - (at 96.71 133.4 120) - (path /5F7D72BB) - (fp_text reference SW26 (at 0 3 300 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973AC) + (at 125.775 124.2) + (descr "Resitance 3 pas") + (tags R) + (path /5B734CF9) + (autoplace_cost180 10) + (fp_text reference D28 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 120) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3 120) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (fp_text user D? (at -5.2 6 120) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973B9) + (at 125.775 121.6) + (descr "Resitance 3 pas") + (tags R) + (path /5B734F9E) + (autoplace_cost180 10) + (fp_text reference D29 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) ) - (pad 2 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 87 "Net-(SW20-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 92 "Net-(SW26-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 87 "Net-(SW20-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 92 "Net-(SW26-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 210) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58 300) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 30 "Net-(D26-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12 300) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 30 "Net-(D26-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98862) - (at 177.6 104.7 180) - (path /5F7D017D) - (fp_text reference SW22 (at 0 3 unlocked) (layer F.SilkS) hide + (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5D8B2928) + (at 125.805 119.02) + (descr "Resitance 3 pas") + (tags R) + (path /5D956FE1) + (autoplace_cost180 10) + (fp_text reference D30 (at 0.5 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_text value D (at -0.6 0) (layer F.Fab) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (net 2 row4)) + (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.22 0.15 0.15)) + (rotate (xyz 0 0 180)) + ) + ) + + (module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5FDCA436) (tstamp 5BEDDC08) + (at 107.9 81.1 180) + (path /5B74AE32) + (fp_text reference J1 (at 0 6.9 180) (layer F.SilkS) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (fp_text value LED (at 0 7.62 180) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) + (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) + (fp_text user GND (at -2.1836 5.0524 180) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (fp_text user LED (at -2.2 2.5 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user GND (at -2.1836 5.0524 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user VCC (at -2.2 0.1 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (fp_text user J1 (at 0 6.9 180) (layer B.SilkS) (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 83 "Net-(SW16-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (pad 1 thru_hole rect (at 0 0 270) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 89 "Net-(SW22-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (pad 2 thru_hole rect (at 0 2.5 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) + (net 41 LED)) + (pad 3 thru_hole rect (at 0 5.1 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 83 "Net-(SW16-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 89 "Net-(SW22-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 27 "Net-(D22-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 27 "Net-(D22-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE987D6) - (at 139.5 104.7 180) - (path /5F7D0189) - (fp_text reference SW20 (at 0 3 unlocked) (layer F.SilkS) hide + (module SofleKeyboard-footprint:MJ-4PP-9 (layer F.Cu) (tedit 5D8BAE3B) (tstamp 5B8BE8A5) + (at 88 85.65 90) + (path /5B742D8C) + (fp_text reference J2 (at -0.889 6.4135 90) (layer F.Fab) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (fp_text value 4PIN (at 0 14 90) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) + (effects (font (size 1 1) (thickness 0.15))) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) + (pad 4 thru_hole oval (at -2.1 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c) (clearance 0.15)) + (pad 1 thru_hole oval (at 2.1 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC) (clearance 0.15)) + (pad 2 thru_hole oval (at 2.1 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 87 "Net-(SW20-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (pad 3 thru_hole oval (at 2.1 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (pad "" np_thru_hole circle (at 0 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at 0 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad 2 thru_hole oval (at -3.85 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 87 "Net-(SW20-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 25 "Net-(D20-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 25 "Net-(D20-Pad2)")) + (pad 3 thru_hole oval (at -3.85 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (pad 4 thru_hole oval (at 0.35 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c) (clearance 0.15)) + (pad 1 thru_hole oval (at -3.85 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC) (clearance 0.15)) + (pad "" np_thru_hole circle (at -1.75 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (pad "" np_thru_hole circle (at -1.75 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) + (model "../../../../../../Users/pluis/Documents/Magic Briefcase/Documents/KiCad/3d/AB2_TRS_3p5MM_PTH.wrl" + (at (xyz 0 0 0)) + (scale (xyz 0.42 0.42 0.42)) + (rotate (xyz 0 0 90)) + ) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98790) - (at 120.5 107.1 180) - (path /5F7D018F) - (fp_text reference SW19 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:OLED_4Pin (layer F.Cu) (tedit 59FC8837) (tstamp 5BEDDC3B) + (at 96.7 74.6) + (descr "Connecteur 6 pins") + (tags "CONN DEV") + (path /5B91007B) + (fp_text reference J3 (at -1.915 1.93 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value OLED (at 3.81 1.27) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer B.SilkS) (width 0.15)) + (pad 4 thru_hole circle (at 7.62 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 51 "Net-(J3-Pad4)")) + (pad 3 thru_hole circle (at 5.08 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 50 "Net-(J3-Pad3)")) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 49 "Net-(J3-Pad2)")) + (pad 1 thru_hole circle (at 0 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 48 "Net-(J3-Pad1)")) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95811) + (at 104.3 69.3 90) + (path /5B911E74) + (attr smd) + (fp_text reference JP1 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 34 GND) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 86 "Net-(SW19-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 80 "Net-(SW13-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 86 "Net-(SW19-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 80 "Net-(SW13-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 24 "Net-(D19-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 24 "Net-(D19-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE986BE) - (at 177.6 85.6 180) - (path /5F7D01A1) - (fp_text reference SW16 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE9581B) + (at 101.7 69.3 90) + (path /5B9120CE) + (attr smd) + (fp_text reference JP2 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 33 VCC) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 77 "Net-(SW10-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 83 "Net-(SW16-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 77 "Net-(SW10-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 83 "Net-(SW16-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 21 "Net-(D16-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 21 "Net-(D16-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98678) - (at 158.6 83.19 180) - (path /5F7D01A7) - (fp_text reference SW15 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95825) + (at 99.2 69.3 90) + (path /5B913646) + (attr smd) + (fp_text reference JP3 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 42 SCL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE98C76) + (at 96.7 69.3 90) + (path /5B913C11) + (attr smd) + (fp_text reference JP4 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 40 SDA) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 82 "Net-(SW15-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 76 "Net-(SW15-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 82 "Net-(SW15-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 76 "Net-(SW15-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 20 "Net-(D15-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 20 "Net-(D15-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98632) - (at 139.5 85.6 180) - (path /5F7D01AD) - (fp_text reference SW14 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE98BB2) + (at 104.3 69.3 90) + (path /5B9141F4) + (attr smd) + (fp_text reference JP5 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_text user SW15 (at 7.1 8.2) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 40 SDA) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + ) + + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95843) + (at 101.7 69.3 90) + (path /5B9141FA) + (attr smd) + (fp_text reference JP6 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + ) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 42 SCL) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 81 "Net-(SW14-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 19 "Net-(D14-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 19 "Net-(D14-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985EC) - (at 120.5 88.1 180) - (path /5F7D01B3) - (fp_text reference SW13 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE9584D) + (at 99.2 69.3 90) + (path /5B914200) + (attr smd) + (fp_text reference JP7 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 33 VCC) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 80 "Net-(SW13-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 74 "Net-(SW13-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 80 "Net-(SW13-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 74 "Net-(SW13-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 18 "Net-(D13-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 18 "Net-(D13-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9851A) - (at 177.6 66.5 180) - (path /5B7237A6) - (fp_text reference SW10 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95857) + (at 96.7 69.3 90) + (path /5B914206) + (attr smd) + (fp_text reference JP8 (at -2.286 -0.127 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 34 GND) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) + (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 70 "Net-(SW10-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 77 "Net-(SW10-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 70 "Net-(SW10-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 77 "Net-(SW10-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 15 "Net-(D10-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 15 "Net-(D10-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE984D4) - (at 158.6 64.09 180) - (path /5B723731) - (fp_text reference SW9 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FD12) (tstamp 61CC20B4) + (at 185.4454 99.3394 270) + (path /620925F6) + (attr smd) + (fp_text reference JP10 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 64 lights) (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 94 BL) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + + (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 61C9FB9E) (tstamp 61CA7193) + (at 112.522 82.804 90) + (path /61D5D1D0) + (attr smd) + (fp_text reference JP9 (at -2.286 0.127 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + ) + (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 41 LED) (clearance 0.1905)) + (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 64 lights) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 76 "Net-(SW15-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 69 "Net-(SW3-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 76 "Net-(SW15-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 69 "Net-(SW3-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 14 "Net-(D9-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 14 "Net-(D9-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9848E) - (at 139.5 66.6 180) - (path /5B723388) - (fp_text reference SW8 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE931) + (at 102.7 80.3 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B8F6780) + (autoplace_cost180 10) + (fp_text reference P1 (at 0 -1.671944 270) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_text user P1 (at 0.2 -1.7 270) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 57 /i2c_c)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 67 "Net-(SW2-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 75 "Net-(SW14-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 13 "Net-(D8-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 39 col4)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 13 "Net-(D8-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98448) - (at 120.5 69.1 180) - (path /5B723C9D) - (fp_text reference SW7 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE93F) + (at 102.7 78.1 270) + (descr "Resitance 3 pas") + (tags R) + (path /5B8F6980) + (autoplace_cost180 10) + (fp_text reference P2 (at 0 -1.671944 270) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) + (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) + (fp_text user P1 (at -0.1 1.7 270) (layer B.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text user P2 (at 0 -1.7 270) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 58 /i2c_d)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 74 "Net-(SW13-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 66 "Net-(SW1-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 74 "Net-(SW13-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 66 "Net-(SW1-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 12 "Net-(D7-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 12 "Net-(D7-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE983BC) - (at 196.7 52.4 180) - (path /5B722B51) - (fp_text reference SW5 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B7351FC) + (at 98.039272 80.311965) + (descr "Resitance 3 pas") + (tags R) + (path /5B739F4A) + (autoplace_cost180 10) + (fp_text reference R1 (at -0.039272 -0.011965 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_text user R1 (at 0 -0.011965 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 40 SDA)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 72 "Net-(SW11-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B735209) + (at 98.039272 78.061965) + (descr "Resitance 3 pas") + (tags R) + (path /5B73A034) + (autoplace_cost180 10) + (fp_text reference R2 (at -0.039272 0.038035 180) (layer F.SilkS) + (effects (font (size 0.8128 0.8128) (thickness 0.15))) + ) + (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide + (effects (font (size 0.5 0.5) (thickness 0.125))) + ) + (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) + (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) + (fp_text user R2 (at 0 0 180) (layer B.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + ) + (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 42 SCL)) + (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 71 "Net-(SW5-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (model discret/resistor.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.3 0.3 0.3)) + (rotate (xyz 0 0 0)) + ) + (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 0.2 0.2 0.2)) + (rotate (xyz 0 0 0)) + ) + ) + + (module SofleKeyboard-footprint:TACT_SWITCH_TVBP06 (layer F.Cu) (tedit 5B8CD44F) (tstamp 5BE9586C) + (at 90 77.5 270) + (path /5B8CE7E7) + (fp_text reference RSW1 (at 0 -1.7 90) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_RST (at 0 2 90) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) + (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) + (fp_line (start -3 -1.8) (end 2.9 -1.8) (layer B.SilkS) (width 0.15)) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (fp_text user RESET (at 0 0 270) (layer F.SilkS) + (effects (font (size 0.8 0.8) (thickness 0.15))) + ) + (pad 2 thru_hole circle (at 3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) + (net 43 RESET)) + (pad 1 thru_hole circle (at -3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 72 "Net-(SW11-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 71 "Net-(SW5-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 8 "Net-(D5-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 36 col1)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 8 "Net-(D5-Pad2)")) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98376) - (at 177.6 47.5 180) - (path /5F74FBCC) - (fp_text reference SW4 (at 0 3 unlocked) (layer F.SilkS) hide + (module SofleKeyboard-footprint:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified (layer F.Cu) (tedit 5D5C0C22) (tstamp 5D8CBBBB) + (at 100 104.5) + (descr "Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html") + (tags "rotary encoder") + (path /5DA04574) + (fp_text reference SW25 (at 4.24 4.6) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (fp_text value Rotary_Encoder_Switch (at 0 7.9) (layer F.Fab) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) - ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 68 "Net-(SW3-Pad3)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 70 "Net-(SW10-Pad1)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) + (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) + (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) + (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) + (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) + (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) + (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) + (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) + (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) + (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) + (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) + (fp_line (start -0.5 0) (end 0.5 0) (layer B.SilkS) (width 0.12)) + (pad A thru_hole circle (at -7.5 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 56 ENCA)) + (pad C thru_hole circle (at -7.5 0) (size 2 2) (drill 1) (layers *.Cu *.Mask) (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 68 "Net-(SW3-Pad3)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 70 "Net-(SW10-Pad1)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 6 "Net-(D4-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 37 col2)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 6 "Net-(D4-Pad2)")) + (pad B thru_hole circle (at -7.5 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 55 ENCB)) + (pad MP thru_hole rect (at 0 -5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad MP thru_hole rect (at 0 5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) + (pad S2 thru_hole circle (at 7 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 53 SW25B)) + (pad S1 thru_hole circle (at 7 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) + (net 54 SW25A)) + (model ${KISYS3DMOD}/Rotary_Encoder.3dshapes/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm.wrl + (at (xyz 0 0 0)) + (scale (xyz 1 1 1)) + (rotate (xyz 0 0 0)) + ) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98330) - (at 158.6 45 180) - (path /5F74EA54) - (fp_text reference SW3 (at 0 3 unlocked) (layer F.SilkS) hide + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5BE98A92) + (at 91.5 93.5) + (path /5B74CE27) + (fp_text reference TH1 (at 0 2.7) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + ) + + (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5D8BB010) + (at 107 93.5) + (path /5B74D0C7) + (fp_text reference TH2 (at 0 2.7) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (effects (font (size 1 1) (thickness 0.15))) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 69 "Net-(SW3-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 68 "Net-(SW3-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 69 "Net-(SW3-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 68 "Net-(SW3-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 4 "Net-(D3-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 38 col3)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 4 "Net-(D3-Pad2)")) + (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) ) - (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982A4) - (at 120.5 50 180) - (path /5B7225DA) - (fp_text reference SW1 (at 0 3 unlocked) (layer F.SilkS) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) - (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) - (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) - (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) - (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) - (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) - (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) - (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) - (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) - (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) - (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) - (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) - (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) - (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) - (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) - (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) - (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) - (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) - (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) - (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) - (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) - (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) - (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) - (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) - (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) - (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) - (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) - (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) - (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) - (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) - (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) - (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) - (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) - (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) - (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) - (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) - (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) - (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) - (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5B8BE94E) + (at 129.975 57.075) + (path /5B74DA95) + (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (fp_text user D? (at -5.2 6) (layer B.SilkS) hide - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 66 "Net-(SW1-Pad1)")) - (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 33 VCC)) - (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) - (net 65 "Net-(SW1-Pad3)")) - (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 34 GND)) - (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 66 "Net-(SW1-Pad1)")) - (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 65 "Net-(SW1-Pad3)")) - (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) - (net 33 VCC)) - (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) - (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) - (net 1 "Net-(D1-Pad2)")) - (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) - (net 54 SW25A)) - (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) - (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) - (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) - (net 1 "Net-(D1-Pad2)")) + (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) ) - (module SofleKeyboard-footprint:LED (layer F.Cu) (tedit 5FDCA436) (tstamp 5BEDDC08) - (at 107.9 81.1 180) - (path /5B74AE32) - (fp_text reference J1 (at 0 6.9 180) (layer F.SilkS) - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value LED (at 0 7.62 180) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start -0.9 6) (end -0.9 4.2) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 6) (end -0.9 6) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 4.2) (end 0.9 6) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 3.4) (end -0.9 1.6) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.9 4.2) (end 0.9 4.2) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 -0.9) (end 0.9 -0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 -0.9) (end 0.9 0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 0.9) (end -0.9 0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 0.9) (end -0.9 -0.9) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 1.6) (end 0.9 1.6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 3.4) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 1.6) (end 0.9 3.4) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 1.6) (end -0.9 3.4) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 4.2) (end 0.9 6) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.9 6) (end -0.9 6) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.9 4.2) (end -0.9 6) (layer F.SilkS) (width 0.15)) - (fp_text user GND (at -2.1836 5.0524 180) (layer F.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15))) - ) - (fp_text user LED (at -2.2 2.5 180) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805C11) (tstamp 5B8BE953) + (at 206.225 61.775) + (path /5B74D1C0) + (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (fp_text user GND (at -2.1836 5.0524 180) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (fp_text user VCC (at -2.2 0.1 180) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) + ) + + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BD0) (tstamp 5B8BE958) + (at 130.025 97.575) + (path /5B74D78B) + (fp_text reference TH5 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (fp_text user J1 (at 0 6.9 180) (layer B.SilkS) - (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (pad 1 thru_hole rect (at 0 0 270) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) - (net 33 VCC)) - (pad 2 thru_hole rect (at 0 2.5 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) - (net 41 LED)) - (pad 3 thru_hole rect (at 0 5.1 180) (size 1.524 1.524) (drill 1) (layers *.Cu *.Mask) - (net 34 GND)) + (pad "" thru_hole circle (at -0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) ) - (module dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F8097A2) - (at 201 122.75 180) - (fp_text reference G*** (at 0 0) (layer B.SilkS) hide - (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BFE) (tstamp 5B8BE95D) + (at 206.175 100.025) + (path /5B74D88C) + (fp_text reference TH6 (at 0 -2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide - (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) - ) - (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) - (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) - (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) - (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) - (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) - (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) - (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) - (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) - (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) - (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) - (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) - (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) - (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) - (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) - (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) - (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) - (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) - (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) - (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) - (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) - (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) - (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) - (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) - (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) - (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) - (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) - (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) - (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) - (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) - (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) - (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) - (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) - (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) - (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) - (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) - (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) - (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) - (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) - (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) - (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) - (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) - (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) - (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) - (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) - (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) - (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) - (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) - (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) - (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) - (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) - (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) - (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) - (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) - (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) - (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) - (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) - (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) - (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) - (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) - (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) - (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) - (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) - (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) - (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) - (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) - (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) - (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) - (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) - (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) - (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) - (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) - (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) - (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) - (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) - (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) - (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) - (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) - (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) - (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) - (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) - (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) - (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) - (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) - (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) - (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) - (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) - (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) - (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) - (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) - (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) - (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) - (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) - (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) - (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) - (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) - (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) - (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) - (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) - (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) - (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) - (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) - (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) - (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) - (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) - (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) - (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) - (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) - (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) - (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) - (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) - (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) - (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) - (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) - (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) - (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) - (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) - (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) - (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) - (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) - (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) - (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) - (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) - (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) - (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) - (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) - (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) - (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) - (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) - (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) - (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) - (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) - (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) - (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) - (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) - (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) - (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) - (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) - (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) - (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) - (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) - (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) - (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) - (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) - (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) - (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) - (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) - (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) - (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) - (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) - (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) - (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) - (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) - ) - - (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F809028) - (at 200.25 122.75) - (fp_text reference G*** (at 0 0) (layer F.SilkS) hide - (effects (font (size 1.524 1.524) (thickness 0.3))) - ) - (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide - (effects (font (size 1.524 1.524) (thickness 0.3))) - ) - (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) - (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) - (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) - (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) - (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) - (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) - (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) - (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) - (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) - (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) - (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) - (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) - (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) - (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) - (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) - (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) - (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) - (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) - (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) - (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) - (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) - (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) - (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) - (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) - (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) - (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) - (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) - (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) - (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) - (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) - (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) - (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) - (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) - (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) - (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) - (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) - (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) - (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) - (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) - (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) - (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) - (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) - (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) - (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) - (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) - (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) - (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) - (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) - (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) - (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) - (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) - (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) - (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) - (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) - (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) - (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) - (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) - (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) - (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) - (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) - (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) - (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) - (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) - (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) - (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) - (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) - (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) - (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) - (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) - (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) - (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) - (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) - (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) - (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) - (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) - (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) - (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) - (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) - (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) - (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) - (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) - (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) - (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) - (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) - (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) - (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) - (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) - (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) - (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) - (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) - (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) - (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) - (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) - (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) - (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) - (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) - (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) - (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) - (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) - (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) - (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) - (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) - (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) - (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) - (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) - (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) - (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) - (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) - (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) - (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) - (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) - (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) - (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) - (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) - (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) - (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) - (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) - (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) - (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) - (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) - (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) - (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) - (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) - (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) - (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) - (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) - (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) - (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) - (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) - (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) - (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) - (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) - (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) - (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) - (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) - (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) - (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) - (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) - (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) - (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) - (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) - (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) - (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) - (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) - (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) - (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) - (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) - (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) - (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) - (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) - (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) - (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) - ) - - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5D8B2928) - (at 125.805 119.02) - (descr "Resitance 3 pas") - (tags R) - (path /5D956FE1) - (autoplace_cost180 10) - (fp_text reference D30 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 52 "Net-(D30-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 52 "Net-(D30-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) - ) - - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973B9) - (at 125.775 121.6) - (descr "Resitance 3 pas") - (tags R) - (path /5B734F9E) - (autoplace_cost180 10) - (fp_text reference D29 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 44 "Net-(D29-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 44 "Net-(D29-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 2 row4)) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) + (pad "" thru_hole circle (at -0.175 -0.025 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE973AC) - (at 125.775 124.2) - (descr "Resitance 3 pas") - (tags R) - (path /5B734CF9) - (autoplace_cost180 10) - (fp_text reference D28 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F8059EF) (tstamp 5B8BE962) + (at 103 119 90) + (path /5B74D98F) + (fp_text reference TH7 (at 0 -2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 32 "Net-(D28-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 32 "Net-(D28-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value HOLE (at 0 2.54 90) (layer F.SilkS) hide + (effects (font (size 0.29972 0.29972) (thickness 0.0762))) ) + (pad "" thru_hole circle (at 0 0 180) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) + (clearance 0.3)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9739F) - (at 110.4248 120.6248) - (descr "Resitance 3 pas") - (tags R) - (path /5B734B62) - (autoplace_cost180 10) - (fp_text reference D27 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module SofleKeyboard-footprint:ProMicro (layer F.Cu) (tedit 5B8BDEB4) (tstamp 5B8BE963) + (at 101 56) + (path /5B722440) + (fp_text reference U1 (at 0 1.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value ProMicro (at 0 -0.8) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) + (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) + (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) + (fp_line (start -10.09 14.44) (end -10.09 -16.04) (layer B.SilkS) (width 0.15)) + (pad 22 thru_hole circle (at -7.521185 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 43 RESET)) + (pad 10 thru_hole circle (at 7.718815 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 9 row2)) + (pad 18 thru_hole circle (at -7.521185 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 35 col0)) + (pad 6 thru_hole circle (at 7.718815 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 42 SCL)) + (pad 4 thru_hole circle (at 7.718815 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 14 thru_hole circle (at -7.521185 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 39 col4)) + (pad 3 thru_hole circle (at 7.718815 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 1 thru_hole circle (at 7.718815 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 41 LED)) + (pad 16 thru_hole circle (at -7.521185 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 37 col2)) + (pad 12 thru_hole circle (at 7.718815 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 31 "Net-(D27-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (pad 19 thru_hole circle (at -7.521185 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 55 ENCB)) + (pad 23 thru_hole circle (at -7.521185 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 34 GND)) + (pad 21 thru_hole circle (at -7.521185 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 33 VCC)) + (pad 20 thru_hole circle (at -7.521185 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 56 ENCA)) + (pad 15 thru_hole circle (at -7.521185 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 38 col3)) + (pad 17 thru_hole circle (at -7.521185 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 36 col1)) + (pad 9 thru_hole circle (at 7.718815 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 7 row1)) + (pad 8 thru_hole circle (at 7.718815 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 5 row0)) + (pad 13 thru_hole circle (at -7.521185 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 54 SW25A)) + (pad 11 thru_hole circle (at 7.718815 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 11 row3)) + (pad 2 thru_hole circle (at 7.718815 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 47 DATA)) + (pad 24 thru_hole circle (at -7.521185 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 45 "Net-(U1-Pad24)")) + (pad 7 thru_hole circle (at 7.718815 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 46 "Net-(U1-Pad7)")) + (pad 5 thru_hole circle (at 7.718815 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (net 40 SDA)) + (pad 1 thru_hole circle (at -8.82 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 41 LED)) + (pad 2 thru_hole circle (at -8.82 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 47 DATA)) + (pad 3 thru_hole circle (at -8.82 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 4 thru_hole circle (at -8.82 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 5 thru_hole circle (at -8.82 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 40 SDA)) + (pad 6 thru_hole circle (at -8.82 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 42 SCL)) + (pad 7 thru_hole circle (at -8.82 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 46 "Net-(U1-Pad7)")) + (pad 8 thru_hole circle (at -8.82 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 5 row0)) + (pad 9 thru_hole circle (at -8.82 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 7 row1)) + (pad 10 thru_hole circle (at -8.82 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 9 row2)) + (pad 11 thru_hole circle (at -8.82 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 11 row3)) + (pad 12 thru_hole circle (at -8.82 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 31 "Net-(D27-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) + (pad 13 thru_hole circle (at 6.42 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 54 SW25A)) + (pad 14 thru_hole circle (at 6.42 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 39 col4)) + (pad 15 thru_hole circle (at 6.42 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 38 col3)) + (pad 16 thru_hole circle (at 6.42 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 37 col2)) + (pad 17 thru_hole circle (at 6.42 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 36 col1)) + (pad 18 thru_hole circle (at 6.42 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 35 col0)) + (pad 19 thru_hole circle (at 6.42 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 55 ENCB)) + (pad 20 thru_hole circle (at 6.42 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 56 ENCA)) + (pad 21 thru_hole circle (at 6.42 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 33 VCC)) + (pad 22 thru_hole circle (at 6.42 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 43 RESET)) + (pad 23 thru_hole circle (at 6.42 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 34 GND)) + (pad 24 thru_hole circle (at 6.42 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (net 45 "Net-(U1-Pad24)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F7EDC95) (tstamp 5BE97392) - (at 100.8 123.6) - (descr "Resitance 3 pas") - (tags R) - (path /5B7349D1) - (autoplace_cost180 10) - (fp_text reference D26 (at 0.7222 -1.1752) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module SofleKeyboard-footprint:jumper_data (layer F.Cu) (tedit 5D87BC97) (tstamp 5BE95B4C) + (at 94 75 270) + (path /5B900157) + (attr smd) + (fp_text reference W1 (at -1.8 0) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.1524))) ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value jumper (at 0 1.524 90) (layer F.SilkS) hide + (effects (font (size 0.8128 0.8128) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 30 "Net-(D26-Pad2)")) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 30 "Net-(D26-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) + (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) + (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) + (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 47 DATA) (clearance 0.1905)) + (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) + (net 58 /i2c_d) (clearance 0.1905)) + (model smd\resistors\R0603.wrl + (offset (xyz 0 0 0.02539999961853028)) + (scale (xyz 0.5 0.5 0.5)) + (rotate (xyz 0 0 0)) ) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97385) - (at 107 97) - (descr "Resitance 3 pas") - (tags R) - (path /5B734844) - (autoplace_cost180 10) - (fp_text reference D25 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9E1) + (at 108.85 124.13) + (path /5F7EC8B3) + (fp_text reference D34 (at 0.95 -0.735) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 53 SW25B)) - (pad 1 smd rect (at -1.775 0) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 2 row4)) - (pad 2 smd rect (at 1.775 0) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 53 SW25B)) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97378) - (at 208.2 105.175 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B727D79) - (autoplace_cost180 10) - (fp_text reference D24 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C999) + (at 120.5 59.5 180) + (path /5F7E6561) + (fp_text reference D31 (at -4.94 -0.76) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 29 "Net-(D24-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 29 "Net-(D24-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 59 "Net-(D31-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9736B) - (at 188.5 106.75 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B727BFE) - (autoplace_cost180 10) - (fp_text reference D23 (at 0.5 0) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9B1) + (at 158.5 53.79) + (path /5F7E9258) + (fp_text reference D32 (at -5.21 -1.04) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 28 "Net-(D23-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 28 "Net-(D23-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 60 "Net-(D31-Pad3)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9735E) - (at 169.25 102.15 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B727A89) - (autoplace_cost180 10) - (fp_text reference D22 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9C9) + (at 197.5 61.25 180) + (path /5F7EC8AD) + (fp_text reference D33 (at -4.84 1.41) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 27 "Net-(D22-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 27 "Net-(D22-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 64 lights)) + (pad 1 smd rect (at -2.2 -0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 2 smd rect (at -2.2 0.875 180) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 64 lights)) + (pad 4 smd rect (at 2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 61 "Net-(D32-Pad3)")) + (pad 2 smd rect (at -2.2 -0.875 180) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97351) - (at 150 98.565 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B727929) - (autoplace_cost180 10) - (fp_text reference D21 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74C9F9) + (at 149.0836 118.2626) + (path /5F7EF5F2) + (fp_text reference D35 (at 0.88 -0.76) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 26 "Net-(D21-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 26 "Net-(D21-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 62 "Net-(D34-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97344) - (at 131 103.175 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B7277CE) - (autoplace_cost180 10) - (fp_text reference D20 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA11) + (at 185.05 120.32) + (path /5F7EF5F8) + (fp_text reference D36 (at 0.87 -0.62) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 25 "Net-(D20-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 25 "Net-(D20-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 63 "Net-(D35-Pad1)")) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97337) - (at 112 102.75 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B72767A) - (autoplace_cost180 10) - (fp_text reference D19 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module LED_SMD:SK6812MINI_underglow_dev_Silk_GND (layer F.Cu) (tedit 61C9F3AC) (tstamp 5F74CA29) + (at 105.75 86.5) + (path /5F918D28) + (fp_text reference D37 (at 0 -2.5) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 24 "Net-(D19-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 11 row3)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 24 "Net-(D19-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text value LED_sk2812_SM (at -0.3 2.7) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_line (start 1.75 1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end 1.75 -1.75) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 -1.75) (end 1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 -1.75) (end -1.75 1.75) (layer F.Fab) (width 0.15)) + (fp_line (start -3.4142 0.15006) (end -0.9942 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.4142 1.60006) (end -3.4142 0.15006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 0.15006) (end -0.9642 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -0.9642 1.60006) (end -3.4142 1.60006) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.41166 -1.60006) (end -0.99166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.41166 -0.15006) (end -3.41166 -1.60006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -1.60006) (end -0.96166 -0.15006) (layer B.SilkS) (width 0.3)) + (fp_line (start -0.96166 -0.15006) (end -3.41166 -0.15006) (layer B.SilkS) (width 0.3)) + (pad 4 smd rect (at 2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 41 LED)) + (pad 1 smd rect (at -2.2 -0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 64 lights)) + (pad 2 smd rect (at -2.2 0.875) (size 2 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 3 smd rect (at 2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 41 LED)) + (pad 4 smd rect (at 2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 1 smd rect (at -2.2 0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 64 lights)) + (pad 2 smd rect (at -2.2 -0.875) (size 2 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9732A) - (at 207.75 86.275 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B725AA2) - (autoplace_cost180 10) - (fp_text reference D18 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9874A) + (at 215.7 90.5 180) + (path /5F7D0195) + (fp_text reference SW18 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) (net 23 "Net-(D18-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) (net 23 "Net-(D18-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) - ) - - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9731D) - (at 188.5 88.775 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B72596D) - (autoplace_cost180 10) - (fp_text reference D17 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 22 "Net-(D17-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 22 "Net-(D17-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97310) - (at 169.725 83.425 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B725841) - (autoplace_cost180 10) - (fp_text reference D16 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988EE) + (at 215.75 109.5 180) + (path /5F7D0171) + (fp_text reference SW24 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 21 "Net-(D16-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 21 "Net-(D16-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 85 "Net-(SW18-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 29 "Net-(D24-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 29 "Net-(D24-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97303) - (at 149.75 81.565 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B72571C) - (autoplace_cost180 10) - (fp_text reference D15 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE988A8) + (at 196.7 109.5 180) + (path /5F7D0177) + (fp_text reference SW23 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 20 "Net-(D15-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 20 "Net-(D15-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 180) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 180) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 28 "Net-(D23-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 28 "Net-(D23-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972F6) - (at 131.25 83.675 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B7255FF) - (autoplace_cost180 10) - (fp_text reference D14 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5FB24B70) + (at 215.8 52.4 180) + (path /5B722CA9) + (fp_text reference SW6 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 19 "Net-(D14-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 19 "Net-(D14-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 10 "Net-(D6-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 10 "Net-(D6-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972E9) - (at 128.5 83.775 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B7254EE) - (autoplace_cost180 10) - (fp_text reference D13 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9881C) + (at 158.6 102.19 180) + (path /5F7D0183) + (fp_text reference SW21 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 18 "Net-(D13-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 9 row2)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 18 "Net-(D13-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 26 "Net-(D21-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 26 "Net-(D21-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972DC) - (at 207.75 67.275 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B7243C0) - (autoplace_cost180 10) - (fp_text reference D12 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985A6) + (at 215.7 71.3 180) + (path /5B723AD3) + (fp_text reference SW12 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 73 "Net-(SW12-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 79 "Net-(SW12-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) (net 17 "Net-(D12-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) (net 17 "Net-(D12-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972CF) - (at 188.25 66.775 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B72424D) - (autoplace_cost180 10) - (fp_text reference D11 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98560) + (at 196.7 71.3 180) + (path /5B72387D) + (fp_text reference SW11 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) (net 16 "Net-(D11-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) (net 16 "Net-(D11-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) - ) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972C2) - (at 169.5 63.65 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B7240EA) - (autoplace_cost180 10) - (fp_text reference D10 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98704) + (at 196.7 90.5 180) + (path /5F7D019B) + (fp_text reference SW17 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 15 "Net-(D10-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 15 "Net-(D10-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 84 "Net-(SW17-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 78 "Net-(SW11-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 22 "Net-(D17-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 22 "Net-(D17-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972B5) - (at 150.25 61.065 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B723FA1) - (autoplace_cost180 10) - (fp_text reference D9 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982EA) + (at 139.5 47.5 180) + (path /5F74DC46) + (fp_text reference SW2 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 14 "Net-(D9-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 14 "Net-(D9-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 3 "Net-(D2-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 3 "Net-(D2-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE972A8) - (at 129.8 63.8 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B723E5F) - (autoplace_cost180 10) - (fp_text reference D8 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F7EF4F0) + (at 177.6 123.8 180) + (path /5F7D72C1) + (fp_text reference SW30 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 13 "Net-(D8-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 13 "Net-(D8-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 94 BL)) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 91 "Net-(SW24-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 94 BL)) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 52 "Net-(D30-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 35 col0)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 52 "Net-(D30-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9729B) - (at 126.8 63.775 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B723D94) - (autoplace_cost180 10) - (fp_text reference D7 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 12 "Net-(D7-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 7 row1)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 12 "Net-(D7-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A4C) + (at 158.6 121.29 180) + (path /5F7D72A9) + (fp_text reference SW29 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - ) - - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9728E) - (at 207.75 50.025 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B722FE1) - (autoplace_cost180 10) - (fp_text reference D6 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 10 "Net-(D6-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 10 "Net-(D6-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 90 "Net-(SW23-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 44 "Net-(D29-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 44 "Net-(D29-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97281) - (at 188 50.25 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B722BAD) - (autoplace_cost180 10) - (fp_text reference D5 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 8 "Net-(D5-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 8 "Net-(D5-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98A06) + (at 139.5 123.7 180) + (path /5F7D72AF) + (fp_text reference SW28 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - ) - - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97274) - (at 169.25 45.425 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B722A8F) - (autoplace_cost180 10) - (fp_text reference D4 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 6 "Net-(D4-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 6 "Net-(D4-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 93 "Net-(SW28-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 32 "Net-(D28-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 32 "Net-(D28-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE97267) - (at 150.5 43.04 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B722950) - (autoplace_cost180 10) - (fp_text reference D3 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5F806503) + (at 117.6 128.4 195) + (path /5F7D72B5) + (fp_text reference SW27 (at 0 3 15 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.199999 15) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 4 "Net-(D3-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 4 "Net-(D3-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 15) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6 15) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 88 "Net-(SW21-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 195) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 285) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 15) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 31 "Net-(D27-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 15) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 195) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 15) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 195) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 15) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 31 "Net-(D27-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9725A) - (at 131 45.7805 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B722847) - (autoplace_cost180 10) - (fp_text reference D2 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9897A) + (at 96.71 133.4 120) + (path /5F7D72BB) + (fp_text reference SW26 (at 0 3 300 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3 120) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 3 "Net-(D2-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 3 "Net-(D2-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_text user D? (at -5.2 6 120) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 92 "Net-(SW26-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 120) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 210) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58 300) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 30 "Net-(D26-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12 300) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 120) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001 300) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 120) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58 300) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 30 "Net-(D26-Pad2)")) ) - (module Diode_SMD:crkbd-diode (layer F.Cu) (tedit 5F6F4F87) (tstamp 5BE9724D) - (at 128.75 45.775 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B7226E7) - (autoplace_cost180 10) - (fp_text reference D1 (at 0.5 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98862) + (at 177.6 104.7 180) + (path /5F7D017D) + (fp_text reference SW22 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value D (at -0.6 0 90) (layer F.Fab) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start 2.7 0.75) (end 2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start -2.7 0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end -2.7 -0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -2.7 -0.75) (end -2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start 2.7 -0.75) (end 2.7 0.75) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer B.SilkS) (width 0.15)) - (fp_line (start 0.5 -0.5) (end 0.5 0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start 0.5 0.5) (end -0.4 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.4 0) (end 0.5 -0.5) (layer F.SilkS) (width 0.15)) - (fp_line (start -0.5 -0.5) (end -0.5 0.5) (layer F.SilkS) (width 0.15)) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 1 "Net-(D1-Pad2)")) - (pad 1 smd rect (at -1.775 0 270) (size 1.3 0.95) (layers B.Cu B.Paste B.Mask) - (net 5 row0)) - (pad 2 smd rect (at 1.775 0 270) (size 1.3 0.95) (layers F.Cu F.Paste F.Mask) - (net 1 "Net-(D1-Pad2)")) - (model Diodes_SMD.3dshapes/SMB_Handsoldering.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.22 0.15 0.15)) - (rotate (xyz 0 0 180)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 89 "Net-(SW22-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 27 "Net-(D22-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 27 "Net-(D22-Pad2)")) ) - (module SofleKeyboard-footprint:ProMicro (layer F.Cu) (tedit 5B8BDEB4) (tstamp 5B8BE963) - (at 101 56) - (path /5B722440) - (fp_text reference U1 (at 0 1.2) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE987D6) + (at 139.5 104.7 180) + (path /5F7D0189) + (fp_text reference SW20 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value ProMicro (at 0 -0.8) (layer F.Fab) hide + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -10.09 14.44) (end -10.09 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start -7.55 14.44) (end -10.09 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start -7.55 -16.04) (end -7.55 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start -10.09 -16.04) (end -7.55 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.15 14.44) (end 5.15 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start 7.69 14.44) (end 5.15 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start 7.69 -16.04) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start 5.15 -16.04) (end 7.69 -16.04) (layer B.SilkS) (width 0.15)) - (fp_line (start -10.09 14.44) (end -10.09 -18.58) (layer B.SilkS) (width 0.15)) - (fp_line (start 7.69 -18.58) (end 7.69 14.44) (layer B.SilkS) (width 0.15)) - (fp_line (start -10.09 -18.58) (end 7.69 -18.58) (layer B.SilkS) (width 0.15)) - (fp_line (start 6.448815 15.635745) (end 8.988815 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start -6.251185 -14.844255) (end -8.791185 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start -8.791185 -14.844255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start -8.791185 -17.384255) (end -8.791185 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 -17.384255) (end -8.791185 -17.384255) (layer F.SilkS) (width 0.15)) - (fp_line (start -8.791185 15.635745) (end -6.251185 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 -14.844255) (end 6.448815 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 15.635745) (end 8.988815 -17.384255) (layer F.SilkS) (width 0.15)) - (fp_line (start 6.448815 -14.844255) (end 6.448815 15.635745) (layer F.SilkS) (width 0.15)) - (fp_line (start -6.251185 15.635745) (end -6.251185 -14.844255) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.988815 15.635745) (end 8.988815 -14.844255) (layer F.SilkS) (width 0.15)) - (pad 22 thru_hole circle (at -7.521185 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 43 RESET)) - (pad 10 thru_hole circle (at 7.718815 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 9 row2)) - (pad 18 thru_hole circle (at -7.521185 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 35 col0)) - (pad 6 thru_hole circle (at 7.718815 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 42 SCL)) - (pad 4 thru_hole circle (at 7.718815 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 34 GND)) - (pad 14 thru_hole circle (at -7.521185 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 39 col4)) - (pad 3 thru_hole circle (at 7.718815 -8.494255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 34 GND)) - (pad 1 thru_hole circle (at 7.718815 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 41 LED)) - (pad 16 thru_hole circle (at -7.521185 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 37 col2)) - (pad 12 thru_hole circle (at 7.718815 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 2 row4)) - (pad 19 thru_hole circle (at -7.521185 -0.874255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 55 ENCB)) - (pad 23 thru_hole circle (at -7.521185 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) - (pad 21 thru_hole circle (at -7.521185 -5.954255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) - (pad 20 thru_hole circle (at -7.521185 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 56 ENCA)) - (pad 15 thru_hole circle (at -7.521185 9.285745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 38 col3)) - (pad 17 thru_hole circle (at -7.521185 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 36 col1)) - (pad 9 thru_hole circle (at 7.718815 6.745745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 7 row1)) - (pad 8 thru_hole circle (at 7.718815 4.205745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 5 row0)) - (pad 13 thru_hole circle (at -7.521185 14.365745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 54 SW25A)) - (pad 11 thru_hole circle (at 7.718815 11.825745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 11 row3)) - (pad 2 thru_hole circle (at 7.718815 -11.034255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 47 DATA)) - (pad 24 thru_hole circle (at -7.521185 -13.574255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 45 "Net-(U1-Pad24)")) - (pad 7 thru_hole circle (at 7.718815 1.665745 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 46 "Net-(U1-Pad7)")) - (pad 5 thru_hole circle (at 7.718815 -3.414255 180) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask B.SilkS) - (net 40 SDA)) - (pad 1 thru_hole circle (at -8.82 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 41 LED)) - (pad 2 thru_hole circle (at -8.82 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 47 DATA)) - (pad 3 thru_hole circle (at -8.82 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 34 GND)) - (pad 4 thru_hole circle (at -8.82 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 34 GND)) - (pad 5 thru_hole circle (at -8.82 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 40 SDA)) - (pad 6 thru_hole circle (at -8.82 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 42 SCL)) - (pad 7 thru_hole circle (at -8.82 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 46 "Net-(U1-Pad7)")) - (pad 8 thru_hole circle (at -8.82 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 5 row0)) - (pad 9 thru_hole circle (at -8.82 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 7 row1)) - (pad 10 thru_hole circle (at -8.82 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 9 row2)) - (pad 11 thru_hole circle (at -8.82 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 11 row3)) - (pad 12 thru_hole circle (at -8.82 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 2 row4)) - (pad 13 thru_hole circle (at 6.42 13.17) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 54 SW25A)) - (pad 14 thru_hole circle (at 6.42 10.63) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 39 col4)) - (pad 15 thru_hole circle (at 6.42 8.09) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 38 col3)) - (pad 16 thru_hole circle (at 6.42 5.55) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 37 col2)) - (pad 17 thru_hole circle (at 6.42 3.01) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 36 col1)) - (pad 18 thru_hole circle (at 6.42 0.47) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 35 col0)) - (pad 19 thru_hole circle (at 6.42 -2.07) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 55 ENCB)) - (pad 20 thru_hole circle (at 6.42 -4.61) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 56 ENCA)) - (pad 21 thru_hole circle (at 6.42 -7.15) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 87 "Net-(SW20-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) - (pad 22 thru_hole circle (at 6.42 -9.69) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 43 RESET)) - (pad 23 thru_hole circle (at 6.42 -12.23) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 34 GND)) - (pad 24 thru_hole circle (at 6.42 -14.77) (size 1.524 1.524) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 45 "Net-(U1-Pad24)")) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 25 "Net-(D20-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 25 "Net-(D20-Pad2)")) ) - (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5D8BB010) - (at 107 93.5) - (path /5B74D0C7) - (fp_text reference TH2 (at 0 2.7) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98790) + (at 120.5 107.1 180) + (path /5F7D018F) + (fp_text reference SW19 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value HOLE (at 0 -2.6) (layer F.Fab) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) - ) - - (module SofleKeyboard-footprint:M2_HOLE_PCB (layer F.Cu) (tedit 5D908E44) (tstamp 5BE98A92) - (at 91.5 93.5) - (path /5B74CE27) - (fp_text reference TH1 (at 0 2.7) (layer F.SilkS) hide + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value HOLE (at 0 -2.6) (layer F.Fab) - (effects (font (size 1 1) (thickness 0.15))) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (pad "" thru_hole circle (at 0 0) (size 4 4) (drill 2.2) (layers *.Cu *.Mask Dwgs.User)) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 86 "Net-(SW19-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 24 "Net-(D19-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 24 "Net-(D19-Pad2)")) ) - (module SofleKeyboard-footprint:OLED_4Pin (layer F.Cu) (tedit 59FC8837) (tstamp 5BEDDC3B) - (at 96.7 74.6) - (descr "Connecteur 6 pins") - (tags "CONN DEV") - (path /5B91007B) - (fp_text reference J3 (at -1.915 1.93 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) - ) - (fp_text value OLED (at 3.81 1.27) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE986BE) + (at 177.6 85.6 180) + (path /5F7D01A1) + (fp_text reference SW16 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer B.SilkS) (width 0.15)) - (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer B.SilkS) (width 0.15)) - (fp_line (start 8.89 1.27) (end -1.27 1.27) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.27 1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.27 -1.27) (end 8.89 -1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start 8.89 -1.27) (end 8.89 1.27) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.27 1.27) (end -1.27 -1.27) (layer F.SilkS) (width 0.15)) - (pad 4 thru_hole circle (at 7.62 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 51 "Net-(J3-Pad4)")) - (pad 3 thru_hole circle (at 5.08 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 50 "Net-(J3-Pad3)")) - (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 49 "Net-(J3-Pad2)")) - (pad 1 thru_hole circle (at 0 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 48 "Net-(J3-Pad1)")) - ) - - (module SofleKeyboard-footprint:jumper_data (layer F.Cu) (tedit 5D87BC97) (tstamp 5BE95B4C) - (at 94 75 270) - (path /5B900157) - (attr smd) - (fp_text reference W1 (at -1.8 0) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value jumper (at 0 1.524 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_poly (pts (xy -0.2 -0.15) (xy 0.2 -0.15) (xy 0.2 0.15) (xy -0.2 0.15)) (layer F.Cu) (width 0.1)) - (pad 1 smd rect (at -0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 47 DATA) (clearance 0.1905)) - (pad 2 smd rect (at 0.50038 0 270) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 58 /i2c_d) (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 83 "Net-(SW16-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 21 "Net-(D16-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 21 "Net-(D16-Pad2)")) ) - (module SofleKeyboard-footprint:TACT_SWITCH_TVBP06 (layer F.Cu) (tedit 5B8CD44F) (tstamp 5BE9586C) - (at 90 77.5 270) - (path /5B8CE7E7) - (fp_text reference RSW1 (at 0 -1.7 90) (layer F.SilkS) hide + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98678) + (at 158.6 83.19 180) + (path /5F7D01A7) + (fp_text reference SW15 (at 0 3 unlocked) (layer F.SilkS) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value SW_RST (at 0 2 90) (layer F.Fab) hide + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -3 -1.8) (end 2.9 -1.8) (layer B.SilkS) (width 0.15)) - (fp_line (start -3 -1.8) (end 3 -1.8) (layer B.SilkS) (width 0.15)) - (fp_line (start 3 1.7) (end -3 1.7) (layer B.SilkS) (width 0.15)) - (fp_line (start 3 -1.8) (end -3 -1.8) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 1.7) (end 3 1.7) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 -1.8) (end 3 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 1.7) (end 3 1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 1.7) (end -3 1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 -1.8) (end -3 -1.1) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 -1.8) (end 3 -1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start 3 1.7) (end 3 1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -3 1.7) (end -3 1.1) (layer B.SilkS) (width 0.15)) - (fp_line (start -3 -1.8) (end -3 -1.1) (layer B.SilkS) (width 0.15)) - (fp_text user RESET (at 0 0 270) (layer F.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15))) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text user RESET (at 0 0 270) (layer F.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15))) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (pad 2 thru_hole circle (at 3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) - (net 43 RESET)) - (pad 1 thru_hole circle (at -3.25 0 270) (size 2 2) (drill 1.3) (layers *.Cu *.Mask) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 82 "Net-(SW15-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 20 "Net-(D15-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 20 "Net-(D15-Pad2)")) ) - (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95857) - (at 96.7 69.3 90) - (path /5B914206) - (attr smd) - (fp_text reference JP8 (at -2.286 -0.127 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) - ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) - ) - (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 34 GND) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) - ) - ) - - (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE9584D) - (at 99.2 69.3 90) - (path /5B914200) - (attr smd) - (fp_text reference JP7 (at -2.286 -0.127 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) - ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) - ) - (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 33 VCC) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) - ) - ) - - (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE95843) - (at 101.7 69.3 90) - (path /5B9141FA) - (attr smd) - (fp_text reference JP6 (at -2.286 -0.127 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) - ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98632) + (at 139.5 85.6 180) + (path /5F7D01AD) + (fp_text reference SW14 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 42 SCL) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - ) - - (module SofleKeyboard-footprint:Jumper (layer B.Cu) (tedit 59FC274F) (tstamp 5BE98BB2) - (at 104.3 69.3 90) - (path /5B9141F4) - (attr smd) - (fp_text reference JP5 (at -2.286 -0.127 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524)) (justify mirror)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_text user SW15 (at 7.1 8.2) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.143 0.889) (end 1.143 0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end 1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end -1.143 -0.889) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.143 -0.889) (end -1.143 0.889) (layer B.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 40 SDA) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers B.Cu B.Paste B.Mask) - (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 81 "Net-(SW14-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 19 "Net-(D14-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 19 "Net-(D14-Pad2)")) ) - (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE98C76) - (at 96.7 69.3 90) - (path /5B913C11) - (attr smd) - (fp_text reference JP4 (at -2.286 0.127 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE985EC) + (at 120.5 88.1 180) + (path /5F7D01B3) + (fp_text reference SW13 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 40 SDA) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 48 "Net-(J3-Pad1)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 80 "Net-(SW13-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 18 "Net-(D13-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 18 "Net-(D13-Pad2)")) ) - (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95825) - (at 99.2 69.3 90) - (path /5B913646) - (attr smd) - (fp_text reference JP3 (at -2.286 0.127 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) - ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) - ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 42 SCL) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 49 "Net-(J3-Pad2)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9851A) + (at 177.6 66.5 180) + (path /5B7237A6) + (fp_text reference SW10 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - ) - - (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE9581B) - (at 101.7 69.3 90) - (path /5B9120CE) - (attr smd) - (fp_text reference JP2 (at -2.286 0.127 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 33 VCC) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 50 "Net-(J3-Pad3)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 77 "Net-(SW10-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 15 "Net-(D10-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 15 "Net-(D10-Pad2)")) ) - (module SofleKeyboard-footprint:Jumper (layer F.Cu) (tedit 59FC274F) (tstamp 5BE95811) - (at 104.3 69.3 90) - (path /5B911E74) - (attr smd) - (fp_text reference JP1 (at -2.286 0.127 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.1524))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE984D4) + (at 158.6 64.09 180) + (path /5B723731) + (fp_text reference SW9 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value Jumper_NO_Small (at -2.755 0 90) (layer F.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.143 -0.889) (end 1.143 -0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 -0.889) (end 1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.143 0.889) (end -1.143 0.889) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.143 0.889) (end -1.143 -0.889) (layer F.SilkS) (width 0.15)) - (pad 2 smd rect (at 0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 34 GND) (clearance 0.1905)) - (pad 1 smd rect (at -0.50038 0 90) (size 0.635 1.143) (layers F.Cu F.Paste F.Mask) - (net 51 "Net-(J3-Pad4)") (clearance 0.1905)) - (model smd\resistors\R0603.wrl - (offset (xyz 0 0 0.02539999961853028)) - (scale (xyz 0.5 0.5 0.5)) - (rotate (xyz 0 0 0)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 76 "Net-(SW15-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 14 "Net-(D9-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 14 "Net-(D9-Pad2)")) ) - (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B7351FC) - (at 98.039272 80.311965) - (descr "Resitance 3 pas") - (tags R) - (path /5B739F4A) - (autoplace_cost180 10) - (fp_text reference R1 (at -0.039272 -0.011965 180) (layer F.SilkS) - (effects (font (size 0.8128 0.8128) (thickness 0.15))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE9848E) + (at 139.5 66.6 180) + (path /5B723388) + (fp_text reference SW8 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_text user R1 (at 0 -0.011965 180) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 40 SDA)) - (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) (net 33 VCC)) - (model discret/resistor.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.3 0.3 0.3)) - (rotate (xyz 0 0 0)) - ) - (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.2 0.2 0.2)) - (rotate (xyz 0 0 0)) - ) - ) - - (module SofleKeyboard-footprint:RESISTOR_mini (layer F.Cu) (tedit 5B8CD4DE) (tstamp 5B735209) - (at 98.039272 78.061965) - (descr "Resitance 3 pas") - (tags R) - (path /5B73A034) - (autoplace_cost180 10) - (fp_text reference R2 (at -0.039272 0.038035 180) (layer F.SilkS) - (effects (font (size 0.8128 0.8128) (thickness 0.15))) - ) - (fp_text value R (at 0 -1.6 180) (layer F.SilkS) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start -1.5 -1) (end 1.5 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 -1) (end 1.5 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.5 1) (end -1.5 1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.5 1) (end -1.5 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1.50114 -1.00076) (end -1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start -1.50114 1.00076) (end 1.50114 1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.50114 1.00076) (end 1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_line (start 1.50114 -1.00076) (end -1.50114 -1.00076) (layer F.SilkS) (width 0.15)) - (fp_text user R2 (at 0 0 180) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) - ) - (pad 2 thru_hole circle (at 2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 42 SCL)) - (pad 1 thru_hole circle (at -2.54 0) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 67 "Net-(SW2-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 75 "Net-(SW14-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) (net 33 VCC)) - (model discret/resistor.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.3 0.3 0.3)) - (rotate (xyz 0 0 0)) - ) - (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.2 0.2 0.2)) - (rotate (xyz 0 0 0)) - ) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 13 "Net-(D8-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 39 col4)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 13 "Net-(D8-Pad2)")) ) - (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE93F) - (at 102.7 78.1 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B8F6980) - (autoplace_cost180 10) - (fp_text reference P2 (at 0 -1.671944 270) (layer F.SilkS) - (effects (font (size 0.8128 0.8128) (thickness 0.15))) - ) - (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) - ) - (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) - (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) - (fp_text user P1 (at -0.1 1.7 270) (layer B.SilkS) hide - (effects (font (size 0.8128 0.8128) (thickness 0.15)) (justify mirror)) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98448) + (at 120.5 69.1 180) + (path /5B723C9D) + (fp_text reference SW7 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text user P2 (at 0 -1.7 270) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 58 /i2c_d)) - (model discret/resistor.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.3 0.3 0.3)) - (rotate (xyz 0 0 0)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.2 0.2 0.2)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 74 "Net-(SW13-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 12 "Net-(D7-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 12 "Net-(D7-Pad2)")) ) - (module SofleKeyboard-footprint:1pin_conn (layer F.Cu) (tedit 5AD20A86) (tstamp 5B8BE931) - (at 102.7 80.3 270) - (descr "Resitance 3 pas") - (tags R) - (path /5B8F6780) - (autoplace_cost180 10) - (fp_text reference P1 (at 0 -1.671944 270) (layer F.SilkS) - (effects (font (size 0.8128 0.8128) (thickness 0.15))) - ) - (fp_text value i2c_pin (at 0 -1.4605 270) (layer F.SilkS) hide - (effects (font (size 0.5 0.5) (thickness 0.125))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE983BC) + (at 196.7 52.4 180) + (path /5B722B51) + (fp_text reference SW5 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_line (start -1 -1) (end 1 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 -1) (end 1 1) (layer B.SilkS) (width 0.15)) - (fp_line (start 1 1) (end -1 1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1 1) (end -1 -1) (layer B.SilkS) (width 0.15)) - (fp_line (start -1 -1) (end -1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start -1 1) (end 1 1) (layer F.SilkS) (width 0.15)) - (fp_line (start 1 1) (end 1 -1) (layer F.SilkS) (width 0.15)) - (fp_line (start 1 -1) (end -1 -1) (layer F.SilkS) (width 0.15)) - (fp_text user P1 (at 0.2 -1.7 270) (layer B.SilkS) - (effects (font (size 0.8 0.8) (thickness 0.15)) (justify mirror)) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (pad 1 thru_hole circle (at 0 0 270) (size 1.397 1.397) (drill 0.8128) (layers *.Cu *.Mask F.SilkS) - (net 57 /i2c_c)) - (model discret/resistor.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.3 0.3 0.3)) - (rotate (xyz 0 0 0)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (model Resistors_ThroughHole.3dshapes/Resistor_Horizontal_RM10mm.wrl - (at (xyz 0 0 0)) - (scale (xyz 0.2 0.2 0.2)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 72 "Net-(SW11-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 71 "Net-(SW5-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 8 "Net-(D5-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 36 col1)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 8 "Net-(D5-Pad2)")) ) - (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BFE) (tstamp 5B8BE95D) - (at 206.175 100.025) - (path /5B74D88C) - (fp_text reference TH6 (at 0 -2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98376) + (at 177.6 47.5 180) + (path /5F74FBCC) + (fp_text reference SW4 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (pad "" thru_hole circle (at -0.175 -0.025 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) - (clearance 0.3)) - ) - - (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BD0) (tstamp 5B8BE958) - (at 130.025 97.575) - (path /5B74D78B) - (fp_text reference TH5 (at 0 -2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (pad "" thru_hole circle (at -0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) - (clearance 0.3)) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 70 "Net-(SW10-Pad1)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 6 "Net-(D4-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 37 col2)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 6 "Net-(D4-Pad2)")) ) - (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805BB1) (tstamp 5B8BE94E) - (at 129.975 57.075) - (path /5B74DA95) - (fp_text reference TH3 (at 0 -2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) - ) - (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE98330) + (at 158.6 45 180) + (path /5F74EA54) + (fp_text reference SW3 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (pad "" thru_hole circle (at 0.025 -0.075 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) - (clearance 0.3)) - ) - - (module SofleKeyboard-footprint:RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm-keebio_modified (layer F.Cu) (tedit 5D5C0C22) (tstamp 5D8CBBBB) - (at 100 104.5) - (descr "Alps rotary encoder, EC12E... with switch, vertical shaft, http://www.alps.com/prod/info/E/HTML/Encoder/Incremental/EC11/EC11E15204A3.html") - (tags "rotary encoder") - (path /5DA04574) - (fp_text reference SW25 (at 4.24 4.6) (layer F.SilkS) hide + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value Rotary_Encoder_Switch (at 0 7.9) (layer F.Fab) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide (effects (font (size 1 1) (thickness 0.15))) ) - (fp_circle (center 0 0) (end 3 0) (layer F.Fab) (width 0.12)) - (fp_circle (center 0 0) (end 3 0) (layer F.SilkS) (width 0.12)) - (fp_line (start 8.5 7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start 8.5 7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start -9 -7.1) (end -9 7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start -9 -7.1) (end 8.5 -7.1) (layer F.CrtYd) (width 0.05)) - (fp_line (start -5 -5.8) (end 6 -5.8) (layer F.Fab) (width 0.12)) - (fp_line (start 6 -5.8) (end 6 5.8) (layer F.Fab) (width 0.12)) - (fp_line (start 6 5.8) (end -6 5.8) (layer F.Fab) (width 0.12)) - (fp_line (start -6 5.8) (end -6 -4.7) (layer F.Fab) (width 0.12)) - (fp_line (start -6 -4.7) (end -5 -5.8) (layer F.Fab) (width 0.12)) - (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start 6.1 5.9) (end 2 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start -2 5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start 0 -3) (end 0 3) (layer F.Fab) (width 0.12)) - (fp_line (start -3 0) (end 3 0) (layer F.Fab) (width 0.12)) - (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer F.SilkS) (width 0.12)) - (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer F.SilkS) (width 0.12)) - (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer F.SilkS) (width 0.12)) - (fp_line (start 0 -0.5) (end 0 0.5) (layer F.SilkS) (width 0.12)) - (fp_line (start -0.5 0) (end 0.5 0) (layer F.SilkS) (width 0.12)) - (fp_line (start -2 -5.9) (end -6.1 -5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start -6.1 -5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start -2 5.9) (end -6.1 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 5.9) (end 2 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 3.5) (end 6.1 5.9) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 -1.3) (end 6.1 1.3) (layer B.SilkS) (width 0.12)) - (fp_line (start 6.1 -5.9) (end 6.1 -3.5) (layer B.SilkS) (width 0.12)) - (fp_line (start 2 -5.9) (end 6.1 -5.9) (layer B.SilkS) (width 0.12)) - (fp_circle (center 0 0) (end 3 0) (layer B.SilkS) (width 0.12)) - (fp_line (start 0 -0.5) (end 0 0.5) (layer B.SilkS) (width 0.12)) - (fp_line (start -0.5 0) (end 0.5 0) (layer B.SilkS) (width 0.12)) - (pad S1 thru_hole circle (at 7 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) - (net 54 SW25A)) - (pad S2 thru_hole circle (at 7 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) - (net 53 SW25B)) - (pad MP thru_hole rect (at 0 5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) - (pad MP thru_hole rect (at 0 -5.6) (size 3.2 2) (drill oval 2.8 1.5) (layers *.Cu *.Mask)) - (pad B thru_hole circle (at -7.5 2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) - (net 55 ENCB)) - (pad C thru_hole circle (at -7.5 0) (size 2 2) (drill 1) (layers *.Cu *.Mask) - (net 34 GND)) - (pad A thru_hole circle (at -7.5 -2.5) (size 2 2) (drill 1) (layers *.Cu *.Mask) - (net 56 ENCA)) - (model ${KISYS3DMOD}/Rotary_Encoder.3dshapes/RotaryEncoder_Alps_EC11E-Switch_Vertical_H20mm.wrl - (at (xyz 0 0 0)) - (scale (xyz 1 1 1)) - (rotate (xyz 0 0 0)) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 69 "Net-(SW3-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 68 "Net-(SW3-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 4 "Net-(D3-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 38 col3)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 4 "Net-(D3-Pad2)")) ) - (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F8059EF) (tstamp 5B8BE962) - (at 103 119 90) - (path /5B74D98F) - (fp_text reference TH7 (at 0 -2.54 90) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (module Button_Switch_Keyboard:SK6812MINI_and_cherry_Silk_GND (layer F.Cu) (tedit 61C9EA7A) (tstamp 5BE982A4) + (at 120.5 50 180) + (path /5B7225DA) + (fp_text reference SW1 (at 0 3 unlocked) (layer F.SilkS) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (fp_text value HOLE (at 0 2.54 90) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (fp_text value SW_PUSH-MX_W_LED (at -0.3 8.2) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) ) - (pad "" thru_hole circle (at 0 0 180) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) - (clearance 0.3)) + (fp_line (start 1.7 7.4) (end 1.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.8) (end 0.8 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 6.2) (end 0.2 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5) (end -1 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 5.6) (end -0.4 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 4.4) (end -1.6 7.7) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.7 3.8) (end -1.7 7.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1.6 3.3) (end -1.7 6.6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 1 3.3) (end -1.7 6) (layer Dwgs.User) (width 0.12)) + (fp_line (start 0.4 3.3) (end -1.7 5.4) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.2 3.3) (end -1.7 4.8) (layer Dwgs.User) (width 0.12)) + (fp_line (start -0.8 3.3) (end -1.7 4.2) (layer Dwgs.User) (width 0.12)) + (fp_line (start 7 7) (end 7 6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -7) (end -6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 7) (end -6 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 7 -7) (end 7 -6) (layer Dwgs.User) (width 0.15)) + (fp_line (start -5.67 -3.7) (end -5.67 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.6) (end -3.800001 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start 2.6 -4.8) (end -4.1 -4.8) (layer B.SilkS) (width 3.5)) + (fp_line (start -4.6 -6.6) (end 3.8 -6.600001) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.6 -4) (end -4.4 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -6.25) (end 4.6 -6.6) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.6 -3) (end -4.6 -4) (layer F.SilkS) (width 0.15)) + (fp_line (start -9.525 -9.525) (end 9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 4.3 -3.3) (end 2.9 -3.3) (layer B.SilkS) (width 0.5)) + (fp_line (start 4.6 -3) (end 4.6 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.8 -3.800001) (end -5.8 -4.7) (layer B.SilkS) (width 0.3)) + (fp_line (start 4.38 -4) (end 4.38 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -1.1) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 4.4 -6.4) (end 3 -6.4) (layer B.SilkS) (width 0.4)) + (fp_line (start 5.9 -4.7) (end 5.9 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -5.7 -1.46) (end -5.9 -1.46) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.7 -1.46) (end 5.9 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -3.9) (end -4.4 -3.2) (layer F.SilkS) (width 0.4)) + (fp_line (start 5.7 -1.3) (end 3 -1.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -4.3 -3.3) (end -2.9 -3.3) (layer F.SilkS) (width 0.5)) + (fp_line (start -5.9 -1.1) (end -2.62 -1.1) (layer B.SilkS) (width 0.15)) + (fp_line (start 9.525 -9.525) (end 9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.67 -3.7) (end 5.67 -1.46) (layer F.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.25) (end -4.6 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 4.6 -4) (end 4.4 -4) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -4.7) (end -5.9 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -4.4 -6.4) (end -3 -6.4) (layer F.SilkS) (width 0.4)) + (fp_line (start 4.4 -6.25) (end 4.6 -6.25) (layer B.SilkS) (width 0.15)) + (fp_line (start -5.9 -3.7) (end -5.7 -3.7) (layer B.SilkS) (width 0.15)) + (fp_line (start -0.4 -3) (end 4.6 -3) (layer B.SilkS) (width 0.15)) + (fp_line (start 5.799999 -3.8) (end 5.8 -4.699999) (layer F.SilkS) (width 0.3)) + (fp_line (start -5.7 -1.3) (end -3 -1.3) (layer B.SilkS) (width 0.5)) + (fp_line (start -4.38 -4) (end -4.38 -6.25) (layer F.SilkS) (width 0.15)) + (fp_line (start 3.9 -6) (end 3.9 -3.5) (layer B.SilkS) (width 1)) + (fp_line (start 4.4 -3.9) (end 4.4 -3.2) (layer B.SilkS) (width 0.4)) + (fp_line (start 6 7) (end 7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 6) (end -7 7) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.9 -1.1) (end 2.62 -1.1) (layer F.SilkS) (width 0.15)) + (fp_line (start 7 -7) (end 6 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -7 -6) (end -7 -7) (layer Dwgs.User) (width 0.15)) + (fp_line (start -3.9 -6) (end -3.9 -3.5) (layer F.SilkS) (width 1)) + (fp_line (start -9.525 9.525) (end -9.525 -9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 9.525 9.525) (end -9.525 9.525) (layer Dwgs.User) (width 0.15)) + (fp_line (start 5.3 -1.6) (end 5.3 -3.4) (layer F.SilkS) (width 0.8)) + (fp_line (start -4.6 -6.25) (end -4.6 -6.6) (layer F.SilkS) (width 0.15)) + (fp_line (start 0.4 -3) (end -4.6 -3) (layer F.SilkS) (width 0.15)) + (fp_line (start 5.9 -3.7) (end 5.7 -3.7) (layer F.SilkS) (width 0.15)) + (fp_line (start -2.6 -4.8) (end 4.1 -4.8) (layer F.SilkS) (width 3.5)) + (fp_line (start 4.17 -5.1) (end 4.17 -2.86) (layer F.SilkS) (width 3)) + (fp_line (start -4.17 -5.1) (end -4.17 -2.86) (layer B.SilkS) (width 3)) + (fp_line (start -5.3 -1.6) (end -5.3 -3.399999) (layer B.SilkS) (width 0.8)) + (fp_line (start -1.37822 7.10006) (end -3.42822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -1.37822 5.65006) (end -1.37822 7.10006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 5.65006) (end -1.37822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42822 7.10006) (end -3.42822 5.65006) (layer B.SilkS) (width 0.3)) + (fp_line (start -3.42568 5.34994) (end -3.42568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -3.42568 3.89994) (end -1.37568 3.89994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 3.89994) (end -1.37568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start -1.37568 5.34994) (end -3.42568 5.34994) (layer F.SilkS) (width 0.3)) + (fp_line (start 1.75 7.75) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end 1.75 3.25) (layer F.Fab) (width 0.15)) + (fp_line (start 1.75 3.25) (end 1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_line (start -1.75 3.25) (end -1.75 7.75) (layer F.Fab) (width 0.15)) + (fp_arc (start 0.465 -0.83) (end 0.4 -3) (angle 84) (layer F.SilkS) (width 0.15)) + (fp_arc (start -0.465 -0.83) (end -0.4 -3) (angle -84) (layer B.SilkS) (width 0.15)) + (fp_arc (start 3.9 -4.6) (end 3.8 -6.600001) (angle 90) (layer F.SilkS) (width 0.15)) + (fp_arc (start 0.865 -1.23) (end 0.8 -3.4) (angle 84) (layer F.SilkS) (width 1)) + (fp_arc (start -3.9 -4.6) (end -3.800001 -6.6) (angle -90) (layer B.SilkS) (width 0.15)) + (fp_arc (start -0.865 -1.23) (end -0.8 -3.4) (angle -84) (layer B.SilkS) (width 1)) + (fp_text user SW_PUSH (at -4.8 8.3) (layer F.Fab) hide + (effects (font (size 1 1) (thickness 0.15))) + ) + (fp_text user D? (at -5.2 6) (layer B.SilkS) hide + (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) + ) + (pad 2 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 4 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 33 VCC)) + (pad 3 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers B.Cu B.Paste B.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 2 smd rect (at -2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 34 GND)) + (pad 1 smd rect (at -2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 66 "Net-(SW1-Pad1)")) + (pad 3 smd rect (at 2.4 4.625 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 65 "Net-(SW1-Pad3)")) + (pad 4 smd rect (at 2.4 6.375 180) (size 1.6 1) (layers F.Cu F.Paste F.Mask) + (net 33 VCC)) + (pad "" np_thru_hole circle (at 2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 0 0 270) (size 4.1 4.1) (drill 4.1) (layers *.Cu *.Mask)) + (pad 6 smd rect (at 5.7 -5.12) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -3.81 -2.54) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad 5 smd rect (at 7 -2.58) (size 2.3 2) (layers F.Cu F.Paste F.Mask) + (net 1 "Net-(D1-Pad2)")) + (pad 6 smd rect (at -5.7 -5.12) (size 2.3 2) (layers F.Cu F.Mask) + (net 54 SW25A)) + (pad "" np_thru_hole circle (at -2.54 -5.08) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 4.5 0 180) (size 1.7 1.7) (drill 1.7) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at 3.81 -2.540001) (size 3 3) (drill 3) (layers *.Cu *.Mask)) + (pad "" np_thru_hole circle (at -5.08 0 180) (size 1.9 1.9) (drill 1.9) (layers *.Cu *.Mask)) + (pad 5 smd rect (at -7 -2.58) (size 2.3 2) (layers B.Cu B.Paste B.Mask) + (net 1 "Net-(D1-Pad2)")) ) - (module SofleKeyboard-footprint:HOLE_M2_TH (layer F.Cu) (tedit 5F805C11) (tstamp 5B8BE953) - (at 206.225 61.775) - (path /5B74D1C0) - (fp_text reference TH4 (at 0 -2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (module dane:gecko-logo (layer B.Cu) (tedit 0) (tstamp 5F8097A2) + (at 201 122.75 180) + (fp_text reference G*** (at 0 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) ) - (fp_text value HOLE (at 0 2.54) (layer F.SilkS) hide - (effects (font (size 0.29972 0.29972) (thickness 0.0762))) + (fp_text value LOGO (at 0.75 0) (layer B.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3)) (justify mirror)) ) - (pad "" thru_hole circle (at -0.225 -0.275 90) (size 4.7 4.7) (drill 4.1) (layers *.Cu *.Mask Dwgs.User) - (clearance 0.3)) + (fp_poly (pts (xy 0.601318 1.845968) (xy 0.629566 1.801122) (xy 0.660606 1.731632) (xy 0.674278 1.696637) + (xy 0.696844 1.640456) (xy 0.717741 1.594158) (xy 0.734739 1.562309) (xy 0.745612 1.549474) + (xy 0.746125 1.549405) (xy 0.757513 1.537853) (xy 0.761992 1.50684) (xy 0.762 1.505208) + (xy 0.766997 1.463388) (xy 0.77927 1.418191) (xy 0.781708 1.411757) (xy 0.79008 1.387564) + (xy 0.794426 1.362926) (xy 0.794778 1.331829) (xy 0.791165 1.288257) (xy 0.783616 1.226195) + (xy 0.782658 1.218829) (xy 0.763898 1.075159) (xy 0.904872 0.890005) (xy 0.949855 0.830926) + (xy 0.989325 0.779091) (xy 1.020787 0.737776) (xy 1.041748 0.710256) (xy 1.049674 0.699857) + (xy 1.063704 0.699863) (xy 1.095604 0.706722) (xy 1.139384 0.718573) (xy 1.189058 0.733553) + (xy 1.238637 0.7498) (xy 1.282132 0.765451) (xy 1.313556 0.778644) (xy 1.325376 0.785602) + (xy 1.346102 0.811208) (xy 1.370849 0.85208) (xy 1.395846 0.900516) (xy 1.417324 0.948813) + (xy 1.431511 0.98927) (xy 1.4351 1.009732) (xy 1.443261 1.038113) (xy 1.462639 1.051849) + (xy 1.485574 1.046296) (xy 1.48961 1.04277) (xy 1.497711 1.024581) (xy 1.488756 1.003156) + (xy 1.47949 0.975875) (xy 1.473922 0.935468) (xy 1.4732 0.915429) (xy 1.476946 0.871614) + (xy 1.489701 0.847647) (xy 1.513732 0.843044) (xy 1.551311 0.857322) (xy 1.601845 0.888082) + (xy 1.64655 0.917306) (xy 1.675006 0.933308) (xy 1.691757 0.937452) (xy 1.701347 0.931102) + (xy 1.706832 0.919604) (xy 1.708613 0.891777) (xy 1.689343 0.877564) (xy 1.676717 0.8763) + (xy 1.654223 0.866178) (xy 1.626807 0.840966) (xy 1.600696 0.808396) (xy 1.582118 0.7762) + (xy 1.577172 0.752711) (xy 1.590575 0.734045) (xy 1.61879 0.713928) (xy 1.653392 0.69651) + (xy 1.685955 0.685939) (xy 1.708055 0.686365) (xy 1.709715 0.68744) (xy 1.731588 0.693257) + (xy 1.754269 0.685777) (xy 1.765097 0.669315) (xy 1.765105 0.668567) (xy 1.756737 0.638731) + (xy 1.735707 0.628278) (xy 1.71695 0.633689) (xy 1.684941 0.643864) (xy 1.644157 0.64804) + (xy 1.603043 0.646526) (xy 1.570045 0.639627) (xy 1.553648 0.627755) (xy 1.557824 0.608475) + (xy 1.575994 0.580265) (xy 1.602145 0.549844) (xy 1.630265 0.523931) (xy 1.654341 0.509245) + (xy 1.66081 0.508) (xy 1.673501 0.499215) (xy 1.67397 0.479469) (xy 1.664464 0.458679) + (xy 1.647228 0.446761) (xy 1.646924 0.446701) (xy 1.624724 0.45296) (xy 1.617287 0.467195) + (xy 1.603162 0.483497) (xy 1.571302 0.505626) (xy 1.527773 0.530536) (xy 1.478638 0.555181) + (xy 1.429963 0.576516) (xy 1.387813 0.591493) (xy 1.358696 0.597067) (xy 1.335049 0.59528) + (xy 1.291811 0.590259) (xy 1.234485 0.582706) (xy 1.168573 0.573323) (xy 1.145794 0.569931) + (xy 1.081186 0.560564) (xy 1.026188 0.553272) (xy 0.985344 0.548605) (xy 0.963198 0.547112) + (xy 0.960582 0.547539) (xy 0.95285 0.559547) (xy 0.934297 0.589102) (xy 0.907459 0.632148) + (xy 0.874868 0.684627) (xy 0.864033 0.702113) (xy 0.830281 0.755791) (xy 0.801348 0.800261) + (xy 0.77975 0.831773) (xy 0.768004 0.846575) (xy 0.766718 0.847153) (xy 0.766221 0.833748) + (xy 0.767225 0.798425) (xy 0.769569 0.744607) (xy 0.773092 0.675722) (xy 0.77763 0.595195) + (xy 0.782195 0.51969) (xy 0.802293 0.19685) (xy 0.674235 -0.048899) (xy 0.637146 -0.121453) + (xy 0.605074 -0.186857) (xy 0.579605 -0.241654) (xy 0.562321 -0.282389) (xy 0.554808 -0.305605) + (xy 0.554914 -0.309249) (xy 0.56465 -0.323371) (xy 0.587103 -0.35488) (xy 0.620019 -0.400643) + (xy 0.661142 -0.457531) (xy 0.708217 -0.52241) (xy 0.73293 -0.556386) (xy 0.781738 -0.623707) + (xy 0.825293 -0.684305) (xy 0.861431 -0.735125) (xy 0.887987 -0.773114) (xy 0.902797 -0.795217) + (xy 0.905128 -0.799381) (xy 0.896186 -0.80958) (xy 0.86952 -0.832363) (xy 0.828007 -0.86546) + (xy 0.774525 -0.906601) (xy 0.711953 -0.953513) (xy 0.67945 -0.977476) (xy 0.613158 -1.026368) + (xy 0.554118 -1.070442) (xy 0.505304 -1.107436) (xy 0.469686 -1.135088) (xy 0.450237 -1.151136) + (xy 0.447524 -1.154032) (xy 0.454771 -1.167292) (xy 0.47848 -1.188562) (xy 0.512775 -1.213763) + (xy 0.551777 -1.238821) (xy 0.589608 -1.259657) (xy 0.61595 -1.270839) (xy 0.661836 -1.279922) + (xy 0.727894 -1.284321) (xy 0.79375 -1.284175) (xy 0.854907 -1.281721) (xy 0.896276 -1.277641) + (xy 0.923462 -1.270895) (xy 0.94207 -1.260443) (xy 0.947715 -1.255604) (xy 0.968302 -1.23905) + (xy 0.982568 -1.240003) (xy 0.996071 -1.251885) (xy 1.010095 -1.275517) (xy 1.01038 -1.291726) + (xy 1.004043 -1.311187) (xy 1.0033 -1.315488) (xy 0.992231 -1.319205) (xy 0.965531 -1.320798) + (xy 0.964777 -1.3208) (xy 0.931477 -1.326577) (xy 0.88835 -1.341359) (xy 0.862393 -1.353161) + (xy 0.825523 -1.37354) (xy 0.807043 -1.390044) (xy 0.801813 -1.408357) (xy 0.80249 -1.419379) + (xy 0.810655 -1.442615) (xy 0.832454 -1.464699) (xy 0.872752 -1.490414) (xy 0.877498 -1.493095) + (xy 0.920395 -1.515607) (xy 0.959172 -1.53333) (xy 0.980872 -1.541067) (xy 1.011086 -1.557217) + (xy 1.02348 -1.58196) (xy 1.014664 -1.608159) (xy 0.989736 -1.623852) (xy 0.963588 -1.62134) + (xy 0.946604 -1.60163) (xy 0.94658 -1.601557) (xy 0.934439 -1.585989) (xy 0.906234 -1.573518) + (xy 0.85735 -1.562119) (xy 0.856189 -1.561899) (xy 0.8112 -1.554096) (xy 0.784146 -1.552285) + (xy 0.768149 -1.557023) (xy 0.756334 -1.568867) (xy 0.755418 -1.570067) (xy 0.743412 -1.58954) + (xy 0.738086 -1.611828) (xy 0.738776 -1.644397) (xy 0.744529 -1.692609) (xy 0.753705 -1.7332) + (xy 0.768434 -1.753337) (xy 0.776307 -1.7567) (xy 0.792654 -1.766329) (xy 0.791173 -1.787066) + (xy 0.78922 -1.792693) (xy 0.770518 -1.819723) (xy 0.746584 -1.827086) (xy 0.725108 -1.81457) + (xy 0.715858 -1.794699) (xy 0.705533 -1.762443) (xy 0.688996 -1.719388) (xy 0.678199 -1.693925) + (xy 0.656494 -1.652148) (xy 0.6354 -1.629869) (xy 0.616907 -1.622674) (xy 0.598938 -1.621182) + (xy 0.586424 -1.62844) (xy 0.575552 -1.649456) (xy 0.562509 -1.689235) (xy 0.560077 -1.697305) + (xy 0.548515 -1.743116) (xy 0.542396 -1.78247) (xy 0.542781 -1.80478) (xy 0.540636 -1.832634) + (xy 0.522993 -1.849417) (xy 0.498441 -1.85211) (xy 0.475573 -1.837697) (xy 0.470613 -1.830133) + (xy 0.465358 -1.805782) (xy 0.477852 -1.78937) (xy 0.486811 -1.778222) (xy 0.491885 -1.759795) + (xy 0.493451 -1.729159) (xy 0.491886 -1.681383) (xy 0.489369 -1.638811) (xy 0.485863 -1.588646) + (xy 0.481217 -1.548358) (xy 0.473348 -1.513756) (xy 0.460173 -1.480648) (xy 0.439611 -1.444843) + (xy 0.409578 -1.402149) (xy 0.367991 -1.348374) (xy 0.312767 -1.279327) (xy 0.307478 -1.272744) + (xy 0.275793 -1.234556) (xy 0.251581 -1.205072) (xy 0.23606 -1.181175) (xy 0.230445 -1.159746) + (xy 0.235952 -1.137667) (xy 0.253798 -1.111818) (xy 0.285198 -1.079081) (xy 0.331368 -1.036338) + (xy 0.393525 -0.980471) (xy 0.436648 -0.94149) (xy 0.612946 -0.781215) (xy 0.507883 -0.682707) + (xy 0.465446 -0.643541) (xy 0.42979 -0.611801) (xy 0.404922 -0.590976) (xy 0.395084 -0.584448) + (xy 0.38554 -0.59463) (xy 0.365898 -0.62192) (xy 0.339327 -0.661764) (xy 0.317966 -0.695224) + (xy 0.258908 -0.778294) (xy 0.184258 -0.86661) (xy 0.100686 -0.953183) (xy 0.01486 -1.031026) + (xy -0.052686 -1.08356) (xy -0.122406 -1.12796) (xy -0.205824 -1.173371) (xy -0.294379 -1.215697) + (xy -0.379512 -1.250837) (xy -0.45085 -1.274214) (xy -0.536598 -1.292799) (xy -0.633428 -1.306921) + (xy -0.731482 -1.315588) (xy -0.820897 -1.317808) (xy -0.864133 -1.315816) (xy -1.016028 -1.290813) + (xy -1.162582 -1.24203) (xy -1.301703 -1.170877) (xy -1.431298 -1.078765) (xy -1.549276 -0.967106) + (xy -1.653546 -0.837309) (xy -1.713517 -0.74295) (xy -1.74279 -0.69215) (xy -1.707554 -0.7366) + (xy -1.664556 -0.7864) (xy -1.609239 -0.844071) (xy -1.547225 -0.90434) (xy -1.484138 -0.961931) + (xy -1.425601 -1.011569) (xy -1.377237 -1.047981) (xy -1.3716 -1.051721) (xy -1.245176 -1.120651) + (xy -1.112029 -1.168911) (xy -0.975949 -1.195852) (xy -0.840726 -1.200823) (xy -0.710149 -1.183173) + (xy -0.669045 -1.172369) (xy -0.589275 -1.14386) (xy -0.499007 -1.103771) (xy -0.407416 -1.056592) + (xy -0.323675 -1.006812) (xy -0.303663 -0.99355) (xy -0.235204 -0.943689) (xy -0.173883 -0.891145) + (xy -0.116659 -0.832288) (xy -0.060488 -0.76349) (xy -0.00233 -0.681122) (xy 0.060859 -0.581556) + (xy 0.108154 -0.502344) (xy 0.1822 -0.376039) (xy 0.062525 -0.264936) (xy 0.017749 -0.224694) + (xy -0.019949 -0.193325) (xy -0.047049 -0.173572) (xy -0.060033 -0.168175) (xy -0.060612 -0.168991) + (xy -0.063064 -0.186795) (xy -0.067286 -0.224592) (xy -0.072716 -0.277084) (xy -0.078788 -0.338971) + (xy -0.079662 -0.348129) (xy -0.09525 -0.512109) (xy -0.299052 -0.315576) (xy -0.368065 -0.2495) + (xy -0.422106 -0.199121) (xy -0.46408 -0.162089) (xy -0.496893 -0.136058) (xy -0.52345 -0.11868) + (xy -0.546657 -0.107608) (xy -0.563249 -0.102132) (xy -0.6089 -0.094084) (xy -0.665441 -0.090868) + (xy -0.725859 -0.092064) (xy -0.783143 -0.097253) (xy -0.830281 -0.106016) (xy -0.860263 -0.117934) + (xy -0.862931 -0.120043) (xy -0.883564 -0.132646) (xy -0.904041 -0.125093) (xy -0.907144 -0.122883) + (xy -0.924869 -0.098751) (xy -0.922059 -0.074377) (xy -0.901259 -0.05852) (xy -0.887849 -0.056509) + (xy -0.857992 -0.051155) (xy -0.817757 -0.038243) (xy -0.775521 -0.021207) (xy -0.73966 -0.003477) + (xy -0.718549 0.011514) (xy -0.717079 0.013464) (xy -0.711706 0.043532) (xy -0.731487 0.075317) + (xy -0.776246 0.1086) (xy -0.802846 0.123172) (xy -0.846133 0.144559) (xy -0.88281 0.161534) + (xy -0.904875 0.170398) (xy -0.923089 0.186663) (xy -0.92562 0.213132) (xy -0.91186 0.238761) + (xy -0.886202 0.253155) (xy -0.865284 0.244529) (xy -0.857715 0.230065) (xy -0.842035 0.212182) + (xy -0.805346 0.195931) (xy -0.771134 0.186141) (xy -0.727794 0.175774) (xy -0.701505 0.1724) + (xy -0.68481 0.176342) (xy -0.670251 0.187925) (xy -0.667477 0.190653) (xy -0.650729 0.22229) + (xy -0.644282 0.26675) (xy -0.647785 0.313935) (xy -0.660888 0.353751) (xy -0.673713 0.370336) + (xy -0.695731 0.399876) (xy -0.693593 0.428694) (xy -0.68473 0.440491) (xy -0.662197 0.449456) + (xy -0.63772 0.443539) (xy -0.623057 0.426451) (xy -0.622302 0.420794) (xy -0.617439 0.399053) + (xy -0.604716 0.362372) (xy -0.587726 0.320675) (xy -0.567687 0.277703) (xy -0.551789 0.253565) + (xy -0.535673 0.243162) (xy -0.519885 0.2413) (xy -0.500593 0.243994) (xy -0.486971 0.255817) + (xy -0.474837 0.282385) (xy -0.463835 0.316562) (xy -0.452711 0.361044) (xy -0.447255 0.399122) + (xy -0.447978 0.418328) (xy -0.445173 0.445306) (xy -0.426489 0.461615) (xy -0.400696 0.46273) + (xy -0.382942 0.451885) (xy -0.369497 0.431384) (xy -0.376492 0.408955) (xy -0.378074 0.406368) + (xy -0.386015 0.379699) (xy -0.391323 0.331391) (xy -0.393631 0.265106) (xy -0.3937 0.249869) + (xy -0.3937 0.118392) (xy -0.295542 -0.017758) (xy -0.259737 -0.067889) (xy -0.23293 -0.103877) + (xy -0.213377 -0.124241) (xy -0.199338 -0.127498) (xy -0.18907 -0.112168) (xy -0.180831 -0.076767) + (xy -0.17288 -0.019814) (xy -0.163474 0.060174) (xy -0.158977 0.098425) (xy -0.150573 0.165099) + (xy -0.142524 0.221828) (xy -0.135513 0.264303) (xy -0.130224 0.288217) (xy -0.128292 0.291896) + (xy -0.116972 0.283703) (xy -0.08983 0.260962) (xy -0.049816 0.226239) (xy 0.000122 0.182097) + (xy 0.057035 0.131103) (xy 0.068815 0.12047) (xy 0.126385 0.068712) (xy 0.177192 0.023547) + (xy 0.218381 -0.01253) (xy 0.247097 -0.037023) (xy 0.260485 -0.047436) (xy 0.261083 -0.047601) + (xy 0.261331 -0.034505) (xy 0.260091 -0.000703) (xy 0.257581 0.049168) (xy 0.254018 0.110473) + (xy 0.252589 0.13335) (xy 0.249029 0.201805) (xy 0.247622 0.26684) (xy 0.248542 0.334176) + (xy 0.251965 0.409529) (xy 0.258064 0.498618) (xy 0.267016 0.607161) (xy 0.267101 0.608138) + (xy 0.27422 0.69206) (xy 0.280255 0.767122) (xy 0.284948 0.829767) (xy 0.28804 0.87644) + (xy 0.289273 0.903583) (xy 0.288988 0.909046) (xy 0.277089 0.904726) (xy 0.247466 0.890094) + (xy 0.204473 0.867394) (xy 0.152465 0.83887) (xy 0.147917 0.836333) (xy 0.095449 0.807477) + (xy 0.051725 0.784305) (xy 0.021069 0.769044) (xy 0.007803 0.763922) (xy 0.007616 0.764025) + (xy -0.012673 0.789778) (xy -0.0446 0.827869) (xy -0.084851 0.874584) (xy -0.130114 0.926209) + (xy -0.177074 0.97903) (xy -0.22242 1.029333) (xy -0.262837 1.073404) (xy -0.295012 1.10753) + (xy -0.315633 1.127996) (xy -0.320628 1.131974) (xy -0.363934 1.15182) (xy -0.414328 1.169997) + (xy -0.46492 1.184616) (xy -0.508821 1.19379) (xy -0.539143 1.19563) (xy -0.546142 1.193778) + (xy -0.571121 1.191617) (xy -0.58999 1.206902) (xy -0.594323 1.231782) (xy -0.592724 1.237166) + (xy -0.583761 1.246549) (xy -0.562816 1.250806) (xy -0.524833 1.250496) (xy -0.491626 1.24834) + (xy -0.443423 1.245136) (xy -0.414705 1.245452) (xy -0.399653 1.250593) (xy -0.392447 1.261864) + (xy -0.389706 1.271203) (xy -0.388787 1.299359) (xy -0.402215 1.330795) (xy -0.432369 1.369713) + (xy -0.464694 1.403648) (xy -0.49351 1.43906) (xy -0.502254 1.466086) (xy -0.49076 1.482293) + (xy -0.470299 1.4859) (xy -0.448594 1.477048) (xy -0.444478 1.463675) (xy -0.433728 1.442632) + (xy -0.406809 1.418521) (xy -0.371663 1.396265) (xy -0.336235 1.380785) (xy -0.308464 1.377) + (xy -0.305673 1.377674) (xy -0.285541 1.395323) (xy -0.268212 1.428926) (xy -0.256625 1.46904) + (xy -0.253722 1.50622) (xy -0.259225 1.526859) (xy -0.26524 1.551343) (xy -0.257711 1.56347) + (xy -0.234824 1.573042) (xy -0.214085 1.563218) (xy -0.204517 1.539056) (xy -0.204663 1.533727) + (xy -0.205747 1.504157) (xy -0.205672 1.461822) (xy -0.205176 1.439757) (xy -0.202076 1.399325) + (xy -0.194331 1.377699) (xy -0.179545 1.368383) (xy -0.178767 1.368174) (xy -0.156212 1.373851) + (xy -0.128007 1.396134) (xy -0.099873 1.428915) (xy -0.077534 1.466087) (xy -0.070565 1.48365) + (xy -0.055069 1.506221) (xy -0.033964 1.508866) (xy -0.010547 1.497366) (xy -0.002679 1.477904) + (xy -0.012457 1.459944) (xy -0.02207 1.455208) (xy -0.036615 1.440044) (xy -0.054483 1.406504) + (xy -0.073371 1.360983) (xy -0.090975 1.309873) (xy -0.104991 1.259568) (xy -0.113115 1.216462) + (xy -0.114248 1.199394) (xy -0.106347 1.16748) (xy -0.083771 1.119396) (xy -0.048112 1.058483) + (xy -0.04377 1.051629) (xy 0.026655 0.941208) (xy 0.162552 1.012297) (xy 0.216038 1.040528) + (xy 0.261262 1.064871) (xy 0.293464 1.08273) (xy 0.307881 1.091511) (xy 0.307889 1.091518) + (xy 0.310779 1.106752) (xy 0.311334 1.141754) (xy 0.309605 1.191003) (xy 0.306511 1.238252) + (xy 0.3021 1.302026) (xy 0.300905 1.346928) (xy 0.303347 1.379329) (xy 0.309844 1.405602) + (xy 0.319018 1.428202) (xy 0.333996 1.470421) (xy 0.342144 1.511313) (xy 0.342621 1.519894) + (xy 0.34897 1.553094) (xy 0.36293 1.564344) (xy 0.376269 1.577095) (xy 0.396877 1.608757) + (xy 0.422088 1.654864) (xy 0.445016 1.7018) (xy 0.483707 1.779631) (xy 0.517056 1.833) + (xy 0.54669 1.86187) (xy 0.574235 1.866205) (xy 0.601318 1.845968)) (layer B.Mask) (width 0.01)) ) - (module SofleKeyboard-footprint:MJ-4PP-9 (layer F.Cu) (tedit 5D8BAE3B) (tstamp 5B8BE8A5) - (at 88 85.65 90) - (path /5B742D8C) - (fp_text reference J2 (at -0.889 6.4135 90) (layer F.Fab) - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text value 4PIN (at 0 14 90) (layer F.Fab) hide - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_line (start -3 12) (end -3 0) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 12) (end -3 12) (layer F.SilkS) (width 0.15)) - (fp_line (start 3 0) (end 3 12) (layer F.SilkS) (width 0.15)) - (fp_line (start -3 0) (end 3 0) (layer F.SilkS) (width 0.15)) - (fp_line (start -4.75 0) (end 1.25 0) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.25 0) (end 1.25 12) (layer B.SilkS) (width 0.15)) - (fp_line (start 1.25 12) (end -4.75 12) (layer B.SilkS) (width 0.15)) - (fp_line (start -4.75 12) (end -4.75 0) (layer B.SilkS) (width 0.15)) - (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) - (effects (font (size 1 1) (thickness 0.15))) - ) - (fp_text user TRRS (at -0.75 6.45 90) (layer F.SilkS) - (effects (font (size 1 1) (thickness 0.15))) + (module dane:gecko-logo (layer F.Cu) (tedit 0) (tstamp 5F809028) + (at 200.25 122.75) + (fp_text reference G*** (at 0 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) ) - (pad "" np_thru_hole circle (at -1.75 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) - (pad "" np_thru_hole circle (at -1.75 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) - (pad 1 thru_hole oval (at -3.85 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 33 VCC) (clearance 0.15)) - (pad 4 thru_hole oval (at 0.35 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 57 /i2c_c) (clearance 0.15)) - (pad 3 thru_hole oval (at -3.85 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 58 /i2c_d)) - (pad 2 thru_hole oval (at -3.85 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 34 GND)) - (pad "" np_thru_hole circle (at 0 1.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) - (pad "" np_thru_hole circle (at 0 8.5 90) (size 1.2 1.2) (drill 1.2) (layers *.Cu *.Mask F.SilkS)) - (pad 3 thru_hole oval (at 2.1 3.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 58 /i2c_d)) - (pad 2 thru_hole oval (at 2.1 6.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 34 GND)) - (pad 1 thru_hole oval (at 2.1 10.3 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 33 VCC) (clearance 0.15)) - (pad 4 thru_hole oval (at -2.1 11.8 90) (size 1.7 2.5) (drill oval 1 1.5) (layers *.Cu *.Mask F.SilkS) - (net 57 /i2c_c) (clearance 0.15)) - (model "../../../../../../Users/pluis/Documents/Magic Briefcase/Documents/KiCad/3d/AB2_TRS_3p5MM_PTH.wrl" - (at (xyz 0 0 0)) - (scale (xyz 0.42 0.42 0.42)) - (rotate (xyz 0 0 90)) + (fp_text value LOGO (at 0.75 0) (layer F.SilkS) hide + (effects (font (size 1.524 1.524) (thickness 0.3))) ) + (fp_poly (pts (xy 0.601318 -1.845968) (xy 0.629566 -1.801122) (xy 0.660606 -1.731632) (xy 0.674278 -1.696637) + (xy 0.696844 -1.640456) (xy 0.717741 -1.594158) (xy 0.734739 -1.562309) (xy 0.745612 -1.549474) + (xy 0.746125 -1.549405) (xy 0.757513 -1.537853) (xy 0.761992 -1.50684) (xy 0.762 -1.505208) + (xy 0.766997 -1.463388) (xy 0.77927 -1.418191) (xy 0.781708 -1.411757) (xy 0.79008 -1.387564) + (xy 0.794426 -1.362926) (xy 0.794778 -1.331829) (xy 0.791165 -1.288257) (xy 0.783616 -1.226195) + (xy 0.782658 -1.218829) (xy 0.763898 -1.075159) (xy 0.904872 -0.890005) (xy 0.949855 -0.830926) + (xy 0.989325 -0.779091) (xy 1.020787 -0.737776) (xy 1.041748 -0.710256) (xy 1.049674 -0.699857) + (xy 1.063704 -0.699863) (xy 1.095604 -0.706722) (xy 1.139384 -0.718573) (xy 1.189058 -0.733553) + (xy 1.238637 -0.7498) (xy 1.282132 -0.765451) (xy 1.313556 -0.778644) (xy 1.325376 -0.785602) + (xy 1.346102 -0.811208) (xy 1.370849 -0.85208) (xy 1.395846 -0.900516) (xy 1.417324 -0.948813) + (xy 1.431511 -0.98927) (xy 1.4351 -1.009732) (xy 1.443261 -1.038113) (xy 1.462639 -1.051849) + (xy 1.485574 -1.046296) (xy 1.48961 -1.04277) (xy 1.497711 -1.024581) (xy 1.488756 -1.003156) + (xy 1.47949 -0.975875) (xy 1.473922 -0.935468) (xy 1.4732 -0.915429) (xy 1.476946 -0.871614) + (xy 1.489701 -0.847647) (xy 1.513732 -0.843044) (xy 1.551311 -0.857322) (xy 1.601845 -0.888082) + (xy 1.64655 -0.917306) (xy 1.675006 -0.933308) (xy 1.691757 -0.937452) (xy 1.701347 -0.931102) + (xy 1.706832 -0.919604) (xy 1.708613 -0.891777) (xy 1.689343 -0.877564) (xy 1.676717 -0.8763) + (xy 1.654223 -0.866178) (xy 1.626807 -0.840966) (xy 1.600696 -0.808396) (xy 1.582118 -0.7762) + (xy 1.577172 -0.752711) (xy 1.590575 -0.734045) (xy 1.61879 -0.713928) (xy 1.653392 -0.69651) + (xy 1.685955 -0.685939) (xy 1.708055 -0.686365) (xy 1.709715 -0.68744) (xy 1.731588 -0.693257) + (xy 1.754269 -0.685777) (xy 1.765097 -0.669315) (xy 1.765105 -0.668567) (xy 1.756737 -0.638731) + (xy 1.735707 -0.628278) (xy 1.71695 -0.633689) (xy 1.684941 -0.643864) (xy 1.644157 -0.64804) + (xy 1.603043 -0.646526) (xy 1.570045 -0.639627) (xy 1.553648 -0.627755) (xy 1.557824 -0.608475) + (xy 1.575994 -0.580265) (xy 1.602145 -0.549844) (xy 1.630265 -0.523931) (xy 1.654341 -0.509245) + (xy 1.66081 -0.508) (xy 1.673501 -0.499215) (xy 1.67397 -0.479469) (xy 1.664464 -0.458679) + (xy 1.647228 -0.446761) (xy 1.646924 -0.446701) (xy 1.624724 -0.45296) (xy 1.617287 -0.467195) + (xy 1.603162 -0.483497) (xy 1.571302 -0.505626) (xy 1.527773 -0.530536) (xy 1.478638 -0.555181) + (xy 1.429963 -0.576516) (xy 1.387813 -0.591493) (xy 1.358696 -0.597067) (xy 1.335049 -0.59528) + (xy 1.291811 -0.590259) (xy 1.234485 -0.582706) (xy 1.168573 -0.573323) (xy 1.145794 -0.569931) + (xy 1.081186 -0.560564) (xy 1.026188 -0.553272) (xy 0.985344 -0.548605) (xy 0.963198 -0.547112) + (xy 0.960582 -0.547539) (xy 0.95285 -0.559547) (xy 0.934297 -0.589102) (xy 0.907459 -0.632148) + (xy 0.874868 -0.684627) (xy 0.864033 -0.702113) (xy 0.830281 -0.755791) (xy 0.801348 -0.800261) + (xy 0.77975 -0.831773) (xy 0.768004 -0.846575) (xy 0.766718 -0.847153) (xy 0.766221 -0.833748) + (xy 0.767225 -0.798425) (xy 0.769569 -0.744607) (xy 0.773092 -0.675722) (xy 0.77763 -0.595195) + (xy 0.782195 -0.51969) (xy 0.802293 -0.19685) (xy 0.674235 0.048899) (xy 0.637146 0.121453) + (xy 0.605074 0.186857) (xy 0.579605 0.241654) (xy 0.562321 0.282389) (xy 0.554808 0.305605) + (xy 0.554914 0.309249) (xy 0.56465 0.323371) (xy 0.587103 0.35488) (xy 0.620019 0.400643) + (xy 0.661142 0.457531) (xy 0.708217 0.52241) (xy 0.73293 0.556386) (xy 0.781738 0.623707) + (xy 0.825293 0.684305) (xy 0.861431 0.735125) (xy 0.887987 0.773114) (xy 0.902797 0.795217) + (xy 0.905128 0.799381) (xy 0.896186 0.80958) (xy 0.86952 0.832363) (xy 0.828007 0.86546) + (xy 0.774525 0.906601) (xy 0.711953 0.953513) (xy 0.67945 0.977476) (xy 0.613158 1.026368) + (xy 0.554118 1.070442) (xy 0.505304 1.107436) (xy 0.469686 1.135088) (xy 0.450237 1.151136) + (xy 0.447524 1.154032) (xy 0.454771 1.167292) (xy 0.47848 1.188562) (xy 0.512775 1.213763) + (xy 0.551777 1.238821) (xy 0.589608 1.259657) (xy 0.61595 1.270839) (xy 0.661836 1.279922) + (xy 0.727894 1.284321) (xy 0.79375 1.284175) (xy 0.854907 1.281721) (xy 0.896276 1.277641) + (xy 0.923462 1.270895) (xy 0.94207 1.260443) (xy 0.947715 1.255604) (xy 0.968302 1.23905) + (xy 0.982568 1.240003) (xy 0.996071 1.251885) (xy 1.010095 1.275517) (xy 1.01038 1.291726) + (xy 1.004043 1.311187) (xy 1.0033 1.315488) (xy 0.992231 1.319205) (xy 0.965531 1.320798) + (xy 0.964777 1.3208) (xy 0.931477 1.326577) (xy 0.88835 1.341359) (xy 0.862393 1.353161) + (xy 0.825523 1.37354) (xy 0.807043 1.390044) (xy 0.801813 1.408357) (xy 0.80249 1.419379) + (xy 0.810655 1.442615) (xy 0.832454 1.464699) (xy 0.872752 1.490414) (xy 0.877498 1.493095) + (xy 0.920395 1.515607) (xy 0.959172 1.53333) (xy 0.980872 1.541067) (xy 1.011086 1.557217) + (xy 1.02348 1.58196) (xy 1.014664 1.608159) (xy 0.989736 1.623852) (xy 0.963588 1.62134) + (xy 0.946604 1.60163) (xy 0.94658 1.601557) (xy 0.934439 1.585989) (xy 0.906234 1.573518) + (xy 0.85735 1.562119) (xy 0.856189 1.561899) (xy 0.8112 1.554096) (xy 0.784146 1.552285) + (xy 0.768149 1.557023) (xy 0.756334 1.568867) (xy 0.755418 1.570067) (xy 0.743412 1.58954) + (xy 0.738086 1.611828) (xy 0.738776 1.644397) (xy 0.744529 1.692609) (xy 0.753705 1.7332) + (xy 0.768434 1.753337) (xy 0.776307 1.7567) (xy 0.792654 1.766329) (xy 0.791173 1.787066) + (xy 0.78922 1.792693) (xy 0.770518 1.819723) (xy 0.746584 1.827086) (xy 0.725108 1.81457) + (xy 0.715858 1.794699) (xy 0.705533 1.762443) (xy 0.688996 1.719388) (xy 0.678199 1.693925) + (xy 0.656494 1.652148) (xy 0.6354 1.629869) (xy 0.616907 1.622674) (xy 0.598938 1.621182) + (xy 0.586424 1.62844) (xy 0.575552 1.649456) (xy 0.562509 1.689235) (xy 0.560077 1.697305) + (xy 0.548515 1.743116) (xy 0.542396 1.78247) (xy 0.542781 1.80478) (xy 0.540636 1.832634) + (xy 0.522993 1.849417) (xy 0.498441 1.85211) (xy 0.475573 1.837697) (xy 0.470613 1.830133) + (xy 0.465358 1.805782) (xy 0.477852 1.78937) (xy 0.486811 1.778222) (xy 0.491885 1.759795) + (xy 0.493451 1.729159) (xy 0.491886 1.681383) (xy 0.489369 1.638811) (xy 0.485863 1.588646) + (xy 0.481217 1.548358) (xy 0.473348 1.513756) (xy 0.460173 1.480648) (xy 0.439611 1.444843) + (xy 0.409578 1.402149) (xy 0.367991 1.348374) (xy 0.312767 1.279327) (xy 0.307478 1.272744) + (xy 0.275793 1.234556) (xy 0.251581 1.205072) (xy 0.23606 1.181175) (xy 0.230445 1.159746) + (xy 0.235952 1.137667) (xy 0.253798 1.111818) (xy 0.285198 1.079081) (xy 0.331368 1.036338) + (xy 0.393525 0.980471) (xy 0.436648 0.94149) (xy 0.612946 0.781215) (xy 0.507883 0.682707) + (xy 0.465446 0.643541) (xy 0.42979 0.611801) (xy 0.404922 0.590976) (xy 0.395084 0.584448) + (xy 0.38554 0.59463) (xy 0.365898 0.62192) (xy 0.339327 0.661764) (xy 0.317966 0.695224) + (xy 0.258908 0.778294) (xy 0.184258 0.86661) (xy 0.100686 0.953183) (xy 0.01486 1.031026) + (xy -0.052686 1.08356) (xy -0.122406 1.12796) (xy -0.205824 1.173371) (xy -0.294379 1.215697) + (xy -0.379512 1.250837) (xy -0.45085 1.274214) (xy -0.536598 1.292799) (xy -0.633428 1.306921) + (xy -0.731482 1.315588) (xy -0.820897 1.317808) (xy -0.864133 1.315816) (xy -1.016028 1.290813) + (xy -1.162582 1.24203) (xy -1.301703 1.170877) (xy -1.431298 1.078765) (xy -1.549276 0.967106) + (xy -1.653546 0.837309) (xy -1.713517 0.74295) (xy -1.74279 0.69215) (xy -1.707554 0.7366) + (xy -1.664556 0.7864) (xy -1.609239 0.844071) (xy -1.547225 0.90434) (xy -1.484138 0.961931) + (xy -1.425601 1.011569) (xy -1.377237 1.047981) (xy -1.3716 1.051721) (xy -1.245176 1.120651) + (xy -1.112029 1.168911) (xy -0.975949 1.195852) (xy -0.840726 1.200823) (xy -0.710149 1.183173) + (xy -0.669045 1.172369) (xy -0.589275 1.14386) (xy -0.499007 1.103771) (xy -0.407416 1.056592) + (xy -0.323675 1.006812) (xy -0.303663 0.99355) (xy -0.235204 0.943689) (xy -0.173883 0.891145) + (xy -0.116659 0.832288) (xy -0.060488 0.76349) (xy -0.00233 0.681122) (xy 0.060859 0.581556) + (xy 0.108154 0.502344) (xy 0.1822 0.376039) (xy 0.062525 0.264936) (xy 0.017749 0.224694) + (xy -0.019949 0.193325) (xy -0.047049 0.173572) (xy -0.060033 0.168175) (xy -0.060612 0.168991) + (xy -0.063064 0.186795) (xy -0.067286 0.224592) (xy -0.072716 0.277084) (xy -0.078788 0.338971) + (xy -0.079662 0.348129) (xy -0.09525 0.512109) (xy -0.299052 0.315576) (xy -0.368065 0.2495) + (xy -0.422106 0.199121) (xy -0.46408 0.162089) (xy -0.496893 0.136058) (xy -0.52345 0.11868) + (xy -0.546657 0.107608) (xy -0.563249 0.102132) (xy -0.6089 0.094084) (xy -0.665441 0.090868) + (xy -0.725859 0.092064) (xy -0.783143 0.097253) (xy -0.830281 0.106016) (xy -0.860263 0.117934) + (xy -0.862931 0.120043) (xy -0.883564 0.132646) (xy -0.904041 0.125093) (xy -0.907144 0.122883) + (xy -0.924869 0.098751) (xy -0.922059 0.074377) (xy -0.901259 0.05852) (xy -0.887849 0.056509) + (xy -0.857992 0.051155) (xy -0.817757 0.038243) (xy -0.775521 0.021207) (xy -0.73966 0.003477) + (xy -0.718549 -0.011514) (xy -0.717079 -0.013464) (xy -0.711706 -0.043532) (xy -0.731487 -0.075317) + (xy -0.776246 -0.1086) (xy -0.802846 -0.123172) (xy -0.846133 -0.144559) (xy -0.88281 -0.161534) + (xy -0.904875 -0.170398) (xy -0.923089 -0.186663) (xy -0.92562 -0.213132) (xy -0.91186 -0.238761) + (xy -0.886202 -0.253155) (xy -0.865284 -0.244529) (xy -0.857715 -0.230065) (xy -0.842035 -0.212182) + (xy -0.805346 -0.195931) (xy -0.771134 -0.186141) (xy -0.727794 -0.175774) (xy -0.701505 -0.1724) + (xy -0.68481 -0.176342) (xy -0.670251 -0.187925) (xy -0.667477 -0.190653) (xy -0.650729 -0.22229) + (xy -0.644282 -0.26675) (xy -0.647785 -0.313935) (xy -0.660888 -0.353751) (xy -0.673713 -0.370336) + (xy -0.695731 -0.399876) (xy -0.693593 -0.428694) (xy -0.68473 -0.440491) (xy -0.662197 -0.449456) + (xy -0.63772 -0.443539) (xy -0.623057 -0.426451) (xy -0.622302 -0.420794) (xy -0.617439 -0.399053) + (xy -0.604716 -0.362372) (xy -0.587726 -0.320675) (xy -0.567687 -0.277703) (xy -0.551789 -0.253565) + (xy -0.535673 -0.243162) (xy -0.519885 -0.2413) (xy -0.500593 -0.243994) (xy -0.486971 -0.255817) + (xy -0.474837 -0.282385) (xy -0.463835 -0.316562) (xy -0.452711 -0.361044) (xy -0.447255 -0.399122) + (xy -0.447978 -0.418328) (xy -0.445173 -0.445306) (xy -0.426489 -0.461615) (xy -0.400696 -0.46273) + (xy -0.382942 -0.451885) (xy -0.369497 -0.431384) (xy -0.376492 -0.408955) (xy -0.378074 -0.406368) + (xy -0.386015 -0.379699) (xy -0.391323 -0.331391) (xy -0.393631 -0.265106) (xy -0.3937 -0.249869) + (xy -0.3937 -0.118392) (xy -0.295542 0.017758) (xy -0.259737 0.067889) (xy -0.23293 0.103877) + (xy -0.213377 0.124241) (xy -0.199338 0.127498) (xy -0.18907 0.112168) (xy -0.180831 0.076767) + (xy -0.17288 0.019814) (xy -0.163474 -0.060174) (xy -0.158977 -0.098425) (xy -0.150573 -0.165099) + (xy -0.142524 -0.221828) (xy -0.135513 -0.264303) (xy -0.130224 -0.288217) (xy -0.128292 -0.291896) + (xy -0.116972 -0.283703) (xy -0.08983 -0.260962) (xy -0.049816 -0.226239) (xy 0.000122 -0.182097) + (xy 0.057035 -0.131103) (xy 0.068815 -0.12047) (xy 0.126385 -0.068712) (xy 0.177192 -0.023547) + (xy 0.218381 0.01253) (xy 0.247097 0.037023) (xy 0.260485 0.047436) (xy 0.261083 0.047601) + (xy 0.261331 0.034505) (xy 0.260091 0.000703) (xy 0.257581 -0.049168) (xy 0.254018 -0.110473) + (xy 0.252589 -0.13335) (xy 0.249029 -0.201805) (xy 0.247622 -0.26684) (xy 0.248542 -0.334176) + (xy 0.251965 -0.409529) (xy 0.258064 -0.498618) (xy 0.267016 -0.607161) (xy 0.267101 -0.608138) + (xy 0.27422 -0.69206) (xy 0.280255 -0.767122) (xy 0.284948 -0.829767) (xy 0.28804 -0.87644) + (xy 0.289273 -0.903583) (xy 0.288988 -0.909046) (xy 0.277089 -0.904726) (xy 0.247466 -0.890094) + (xy 0.204473 -0.867394) (xy 0.152465 -0.83887) (xy 0.147917 -0.836333) (xy 0.095449 -0.807477) + (xy 0.051725 -0.784305) (xy 0.021069 -0.769044) (xy 0.007803 -0.763922) (xy 0.007616 -0.764025) + (xy -0.012673 -0.789778) (xy -0.0446 -0.827869) (xy -0.084851 -0.874584) (xy -0.130114 -0.926209) + (xy -0.177074 -0.97903) (xy -0.22242 -1.029333) (xy -0.262837 -1.073404) (xy -0.295012 -1.10753) + (xy -0.315633 -1.127996) (xy -0.320628 -1.131974) (xy -0.363934 -1.15182) (xy -0.414328 -1.169997) + (xy -0.46492 -1.184616) (xy -0.508821 -1.19379) (xy -0.539143 -1.19563) (xy -0.546142 -1.193778) + (xy -0.571121 -1.191617) (xy -0.58999 -1.206902) (xy -0.594323 -1.231782) (xy -0.592724 -1.237166) + (xy -0.583761 -1.246549) (xy -0.562816 -1.250806) (xy -0.524833 -1.250496) (xy -0.491626 -1.24834) + (xy -0.443423 -1.245136) (xy -0.414705 -1.245452) (xy -0.399653 -1.250593) (xy -0.392447 -1.261864) + (xy -0.389706 -1.271203) (xy -0.388787 -1.299359) (xy -0.402215 -1.330795) (xy -0.432369 -1.369713) + (xy -0.464694 -1.403648) (xy -0.49351 -1.43906) (xy -0.502254 -1.466086) (xy -0.49076 -1.482293) + (xy -0.470299 -1.4859) (xy -0.448594 -1.477048) (xy -0.444478 -1.463675) (xy -0.433728 -1.442632) + (xy -0.406809 -1.418521) (xy -0.371663 -1.396265) (xy -0.336235 -1.380785) (xy -0.308464 -1.377) + (xy -0.305673 -1.377674) (xy -0.285541 -1.395323) (xy -0.268212 -1.428926) (xy -0.256625 -1.46904) + (xy -0.253722 -1.50622) (xy -0.259225 -1.526859) (xy -0.26524 -1.551343) (xy -0.257711 -1.56347) + (xy -0.234824 -1.573042) (xy -0.214085 -1.563218) (xy -0.204517 -1.539056) (xy -0.204663 -1.533727) + (xy -0.205747 -1.504157) (xy -0.205672 -1.461822) (xy -0.205176 -1.439757) (xy -0.202076 -1.399325) + (xy -0.194331 -1.377699) (xy -0.179545 -1.368383) (xy -0.178767 -1.368174) (xy -0.156212 -1.373851) + (xy -0.128007 -1.396134) (xy -0.099873 -1.428915) (xy -0.077534 -1.466087) (xy -0.070565 -1.48365) + (xy -0.055069 -1.506221) (xy -0.033964 -1.508866) (xy -0.010547 -1.497366) (xy -0.002679 -1.477904) + (xy -0.012457 -1.459944) (xy -0.02207 -1.455208) (xy -0.036615 -1.440044) (xy -0.054483 -1.406504) + (xy -0.073371 -1.360983) (xy -0.090975 -1.309873) (xy -0.104991 -1.259568) (xy -0.113115 -1.216462) + (xy -0.114248 -1.199394) (xy -0.106347 -1.16748) (xy -0.083771 -1.119396) (xy -0.048112 -1.058483) + (xy -0.04377 -1.051629) (xy 0.026655 -0.941208) (xy 0.162552 -1.012297) (xy 0.216038 -1.040528) + (xy 0.261262 -1.064871) (xy 0.293464 -1.08273) (xy 0.307881 -1.091511) (xy 0.307889 -1.091518) + (xy 0.310779 -1.106752) (xy 0.311334 -1.141754) (xy 0.309605 -1.191003) (xy 0.306511 -1.238252) + (xy 0.3021 -1.302026) (xy 0.300905 -1.346928) (xy 0.303347 -1.379329) (xy 0.309844 -1.405602) + (xy 0.319018 -1.428202) (xy 0.333996 -1.470421) (xy 0.342144 -1.511313) (xy 0.342621 -1.519894) + (xy 0.34897 -1.553094) (xy 0.36293 -1.564344) (xy 0.376269 -1.577095) (xy 0.396877 -1.608757) + (xy 0.422088 -1.654864) (xy 0.445016 -1.7018) (xy 0.483707 -1.779631) (xy 0.517056 -1.833) + (xy 0.54669 -1.86187) (xy 0.574235 -1.866205) (xy 0.601318 -1.845968)) (layer F.Mask) (width 0.01)) ) (gr_text "Sofle RGB by Dane Evans, original by Josef Adamacik" (at 113.75 39) (layer F.SilkS) (tstamp 5FDB143C)